-- File Name : ZTE-AN-IEEE1588-MIB.mib
-- Date : 2011-01-26
-- Author : ZTE Shanghai NMS Dept.
--
-- ZTE CPE Version MIB for Access Node.
--
-------------------------------------------------------------------------------
ZTE-AN-IEEE1588-MIB DEFINITIONS ::= BEGIN
IMPORTS
MODULE-IDENTITY, OBJECT-TYPE, NOTIFICATION-TYPE,
IpAddress, TimeTicks, Integer32, Counter32,
Gauge32, Counter64 FROM SNMPv2-SMI
RowStatus, TruthValue, DisplayString,
TEXTUAL-CONVENTION FROM SNMPv2-TC
SnmpAdminString FROM SNMP-FRAMEWORK-MIB
InetAddress,InetAddressType FROM INET-ADDRESS-MIB
zxAn FROM ZTE-AN-TC-MIB;
zxAnIeee1588Mib MODULE-IDENTITY
LAST-UPDATED "201101261500Z"
ORGANIZATION "ZTE Corporation"
CONTACT-INFO "zhangzhikun
Mail: zhang.zhikun@zte.com.cn
Tel : 021-68895557"
DESCRIPTION "The MIB module for the management of IEEE1588 ."
::= {zxAn 66}
-------------------------------------------------------------------------------
-- Following management objects are defined.
-- 1. PTP Management : zxAnPtpTable
-- 2. PTP Management : zxAnPtpRemoteSrcTable
-- 3. Synchronization Time Management: zxAnSyncTime1ppsSrcTable
-- 4. Synchronization Time Management: zxAnSyncTimeTodSrcTable
-- 5. Synchronization Time Management: zxAnSyncTimeOutputPortTable
-------------------------------------------------------------------------------
zxAnPtpMgmt OBJECT IDENTIFIER ::= {zxAnIeee1588Mib 1}
zxAnSyncTimeClkSrcMgmt OBJECT IDENTIFIER ::= {zxAnIeee1588Mib 2}
-------------------------------------------------------------------------------
-- 1. PTP Management : zxAnPtpTable
-------------------------------------------------------------------------------
zxAnPtpTable OBJECT-TYPE
SYNTAX SEQUENCE OF ZxAnPtpEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "This table includes PTP configuration information in NE
equipment."
::= { zxAnPtpMgmt 2 }
zxAnPtpEntry OBJECT-TYPE
SYNTAX ZxAnPtpEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An entry in zxAnPtpTable."
INDEX {zxAnPtpRack,zxAnPtpShelf,
zxAnPtpSlot,zxAnPtpId}
::= { zxAnPtpTable 1 }
ZxAnPtpEntry ::= SEQUENCE {
zxAnPtpRack Integer32,
zxAnPtpShelf Integer32,
zxAnPtpSlot Integer32,
zxAnPtpId Integer32,
zxAnPtpClockType INTEGER,
zxAnPtpSlaveOnly TruthValue,
zxAnPtpDomainNumber Integer32,
zxAnPtpProtocolIpAddrType InetAddressType,
zxAnPtpProtocolIpAddress InetAddress,
zxAnPtpEthWorkMode INTEGER,
zxAnPtpPacketsMode INTEGER,
zxAnPtpTwoStepFlag TruthValue,
zxAnPtpSendPacketsRate Integer32,
zxAnPtpClockStatus INTEGER,
zxAnPtpUtcTime DisplayString,
zxAnPtpRowStatus RowStatus
}
zxAnPtpRack OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This object indicates the rack number."
::= { zxAnPtpEntry 1 }
zxAnPtpShelf OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This object indicates the shelf number."
::= { zxAnPtpEntry 2 }
zxAnPtpSlot OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This object indicates the slot number."
::= { zxAnPtpEntry 3 }
zxAnPtpId OBJECT-TYPE
SYNTAX Integer32(1..4)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The PTP node ID."
::= { zxAnPtpEntry 4 }
zxAnPtpClockType OBJECT-TYPE
SYNTAX INTEGER
{
ordinary(1),
boundary(2)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The value of clock type shall indicate the type of PTP node
as defined in table 42 of IEEE1588-2008."
REFERENCE
"Clause 15.5.3.1.2.1 of IEEE1588-2008"
DEFVAL { ordinary }
::= { zxAnPtpEntry 5 }
zxAnPtpSlaveOnly OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The value of defaultDS.slaveOnly shall be TRUE if the clock
is a slave-only clock; see 9.2.2.
The value shall be FALSE if the clock is a non-slave-only
clock;
see 9.2.3 of IEEE1588-2008."
REFERENCE
"Clause 8.2.1.4.4, IEEE1588-2008"
DEFVAL { true }
::= { zxAnPtpEntry 6 }
zxAnPtpDomainNumber OBJECT-TYPE
SYNTAX Integer32(0..255)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The value of defaultDS.domainNumber is the domain attribute
(see 7.1 of IEEE1588-2008) of the local clock.
Value 0 indicates the default domain."
REFERENCE
"Clause 8.2.1.4.3, IEEE1588-2008"
DEFVAL { 0 }
::= { zxAnPtpEntry 7 }
zxAnPtpProtocolIpAddrType OBJECT-TYPE
SYNTAX InetAddressType
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This object indicates the type of IP address denoted
in zxAnPtpProtocolIpAddress object."
DEFVAL { ipv4 }
::= { zxAnPtpEntry 8 }
zxAnPtpProtocolIpAddress OBJECT-TYPE
SYNTAX InetAddress
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The value of protocolAddress shall be the protocol address
of the port indicated by the targetPortIdentity. "
REFERENCE
"Clause 15.5.3.1.2.5 of IEEE1588-2008"
::= { zxAnPtpEntry 9 }
zxAnPtpEthWorkMode OBJECT-TYPE
SYNTAX INTEGER
{
syncE(1),
notSyncE(2)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The PTP node ethernet work mode."
DEFVAL { syncE }
::= { zxAnPtpEntry 10 }
zxAnPtpPacketsMode OBJECT-TYPE
SYNTAX INTEGER
{
unicast(1),
multicast(2),
broadcast(3)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The PTP node packets mode."
DEFVAL { multicast }
::= { zxAnPtpEntry 11 }
zxAnPtpTwoStepFlag OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The value of defaultDS.twoStepFlag shall be TRUE
if the clock is a two-step clock;
otherwise, the value shall be FALSE."
REFERENCE
"Clause 8.2.1.2.1, IEEE1588-2008"
DEFVAL { false }
::= { zxAnPtpEntry 12 }
zxAnPtpSendPacketsRate OBJECT-TYPE
SYNTAX Integer32(1..512)
UNITS "pps"
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The sending packets rate of PTP node.
The value should be 2^n, such as 1, 2, 4, 8, 16
and so on."
::= { zxAnPtpEntry 13 }
zxAnPtpClockStatus OBJECT-TYPE
SYNTAX INTEGER
{
freeRun(1),
holdover(2),
acquisition(3),
locked(4)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"State of the clock servo loop."
::= { zxAnPtpEntry 14 }
zxAnPtpUtcTime OBJECT-TYPE
SYNTAX DisplayString ( SIZE ( 1 .. 19 ) )
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The UTC time of PTP node. The format is
yyyy-mm-dd HH:MM:SS.For example, 2001-01-01 02:22:33."
::= { zxAnPtpEntry 15 }
zxAnPtpRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The row status of this entry."
::= { zxAnPtpEntry 50 }
-------------------------------------------------------------------------------
-- 2. PTP Management : zxAnPtpRemoteSrcTable
-------------------------------------------------------------------------------
zxAnPtpRemoteSrcTable OBJECT-TYPE
SYNTAX SEQUENCE OF ZxAnPtpRemoteSrcEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "This table includes PTP source configuration information
in NE equipment."
::= { zxAnPtpMgmt 3 }
zxAnPtpRemoteSrcEntry OBJECT-TYPE
SYNTAX ZxAnPtpRemoteSrcEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An entry in zxAnPtpRemoteSrcTable."
INDEX {zxAnPtpRack,zxAnPtpShelf,
zxAnPtpSlot,zxAnPtpId,
zxAnPtpRemoteSrcIpAddrType,zxAnPtpRemoteSrcIpAddress}
::= { zxAnPtpRemoteSrcTable 1 }
ZxAnPtpRemoteSrcEntry ::= SEQUENCE {
zxAnPtpRemoteSrcIpAddrType InetAddressType,
zxAnPtpRemoteSrcIpAddress InetAddress,
zxAnPtpRemoteSrcDomainNumber Integer32,
zxAnPtpRemoteSrcPathDelayAdjust Integer32,
zxAnPtpRemoteSrcWorkStatus INTEGER,
zxAnPtpRemoteSrcRowStatus RowStatus
}
zxAnPtpRemoteSrcIpAddrType OBJECT-TYPE
SYNTAX InetAddressType
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This object indicates the type of IP address denoted
in zxAnPtpRemoteSrcIpAddress object."
DEFVAL { ipv4 }
::= { zxAnPtpRemoteSrcEntry 1 }
zxAnPtpRemoteSrcIpAddress OBJECT-TYPE
SYNTAX InetAddress
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The PTP source IP address."
::= { zxAnPtpRemoteSrcEntry 2 }
zxAnPtpRemoteSrcDomainNumber OBJECT-TYPE
SYNTAX Integer32(0..255)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The value of defaultDS.domainNumber is the domain attribute
(see 7.1 of IEEE1588-2008) of the local clock.
Value 0 indicates the default domain."
REFERENCE
"Clause 8.2.1.4.3, IEEE1588-2008"
DEFVAL { 0 }
::= { zxAnPtpRemoteSrcEntry 3 }
zxAnPtpRemoteSrcPathDelayAdjust OBJECT-TYPE
SYNTAX Integer32(-1000000..1000000)
UNITS "ns"
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The value of currentDS.meanPathDelay is an
implementation-specific representation of the
current value of the mean propagation time between
a master and slave clock as computed by the slave."
REFERENCE
"Clause 8.2.2.4, IEEE1588-2008"
::= { zxAnPtpRemoteSrcEntry 4 }
zxAnPtpRemoteSrcWorkStatus OBJECT-TYPE
SYNTAX INTEGER
{
none(1),
active(2),
standby(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The remote PTP source work status,
active(2) indicates PTP source is active,
standby(3) indicates PTP source is standby source,
none(1) indicates PTP source is invalid."
::= { zxAnPtpRemoteSrcEntry 5 }
zxAnPtpRemoteSrcRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The row status of this entry."
::= { zxAnPtpRemoteSrcEntry 50 }
-------------------------------------------------------------------------------
-- 3. Synchronization Time Management: zxAnSyncTime1ppsSrcTable
-------------------------------------------------------------------------------
zxAnSyncTime1ppsSrcTable OBJECT-TYPE
SYNTAX SEQUENCE OF ZxAnSyncTime1ppsSrcEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "This table includes 1PPS source information in NE
equipment."
::= { zxAnSyncTimeClkSrcMgmt 3 }
zxAnSyncTime1ppsSrcEntry OBJECT-TYPE
SYNTAX ZxAnSyncTime1ppsSrcEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An entry in zxAnSyncTime1ppsSrcTable."
INDEX {zxAnSyncTime1ppsSrcRack,zxAnSyncTime1ppsSrcShelf,
zxAnSyncTime1ppsSrcSlot,zxAnSyncTime1ppsSrcId}
::= { zxAnSyncTime1ppsSrcTable 1 }
ZxAnSyncTime1ppsSrcEntry ::= SEQUENCE {
zxAnSyncTime1ppsSrcRack Integer32,
zxAnSyncTime1ppsSrcShelf Integer32,
zxAnSyncTime1ppsSrcSlot Integer32,
zxAnSyncTime1ppsSrcId Integer32,
zxAnSyncTime1ppsSrcSignalType INTEGER,
zxAnSyncTime1ppsSrcPriority Integer32,
zxAnSyncTime1ppsSrcPortType INTEGER,
zxAnSyncTime1ppsSrcPort Integer32,
zxAnSyncTime1ppsSrcWorkStatus INTEGER,
zxAnSyncTime1ppsSrcValidStatus INTEGER,
zxAnSyncTime1ppsSrcPortStatus INTEGER,
zxAnSyncTime1ppsSrcRowStatus RowStatus
}
zxAnSyncTime1ppsSrcRack OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This object indicates the rack number."
::= { zxAnSyncTime1ppsSrcEntry 1 }
zxAnSyncTime1ppsSrcShelf OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This object indicates the shelf number."
::= { zxAnSyncTime1ppsSrcEntry 2 }
zxAnSyncTime1ppsSrcSlot OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This object indicates the slot number."
::= { zxAnSyncTime1ppsSrcEntry 3 }
zxAnSyncTime1ppsSrcId OBJECT-TYPE
SYNTAX Integer32(1..4)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The ID of 1PPS signal source."
::= { zxAnSyncTime1ppsSrcEntry 4 }
zxAnSyncTime1ppsSrcSignalType OBJECT-TYPE
SYNTAX INTEGER
{
ptp(1),
onepps(2)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION "The type of 1PPS signal source."
::= { zxAnSyncTime1ppsSrcEntry 5 }
zxAnSyncTime1ppsSrcPriority OBJECT-TYPE
SYNTAX Integer32(1..255)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The priority of 1PPS signal source, value 1 is the
highest priority."
::= { zxAnSyncTime1ppsSrcEntry 6 }
zxAnSyncTime1ppsSrcPortType OBJECT-TYPE
SYNTAX INTEGER
{
typeTtl(1),
type422(2)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION "The 1PPS signal source port type.
It is valid only for the 'onepps' signal type."
::= { zxAnSyncTime1ppsSrcEntry 7 }
zxAnSyncTime1ppsSrcPort OBJECT-TYPE
SYNTAX Integer32(1..4)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The physical port number.
It is valid only for the 'onepps' signal type.
"
::= { zxAnSyncTime1ppsSrcEntry 8 }
zxAnSyncTime1ppsSrcWorkStatus OBJECT-TYPE
SYNTAX INTEGER
{
none(1),
active(2),
standby(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The 1PPS signal source work status,
active(2) indicates PTP source is active,
standby(3) indicates PTP source is standby source,
none(1) indicates PTP source is invalid."
::= { zxAnSyncTime1ppsSrcEntry 9 }
zxAnSyncTime1ppsSrcValidStatus OBJECT-TYPE
SYNTAX INTEGER
{
valid(1),
invalid(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The 1PPS singnal source work status.
When the value is invalid,
then zxAnSyncTime1ppsSrcWorkStatus is none."
::= { zxAnSyncTime1ppsSrcEntry 10 }
zxAnSyncTime1ppsSrcPortStatus OBJECT-TYPE
SYNTAX INTEGER
{
none(1),
normal(2),
signalLos(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The 1PPS signal source port status.
It is valid only for the 'onepps' signal type.
If zxAnSyncTime1ppsSrcSignalType is 'ptp',
then the value is none.
When the value is none or signalLos, then
zxAnSyncTime1ppsSrcValidStatus is invalid. "
::= { zxAnSyncTime1ppsSrcEntry 11 }
zxAnSyncTime1ppsSrcRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The row status of this entry."
::= { zxAnSyncTime1ppsSrcEntry 30 }
-------------------------------------------------------------------------------
-- 4. Synchronization Time Management: zxAnSyncTimeTodSrcTable
-------------------------------------------------------------------------------
zxAnSyncTimeTodSrcTable OBJECT-TYPE
SYNTAX SEQUENCE OF ZxAnSyncTimeTodSrcEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "This table includes TOD source information in NE
equipment."
::= { zxAnSyncTimeClkSrcMgmt 4 }
zxAnSyncTimeTodSrcEntry OBJECT-TYPE
SYNTAX ZxAnSyncTimeTodSrcEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An entry in zxAnSyncTimeTodSrcTable."
INDEX {zxAnSyncTimeTodSrcRack,zxAnSyncTimeTodSrcShelf,
zxAnSyncTimeTodSrcSlot,zxAnSyncTimeTodSrcPort}
::= { zxAnSyncTimeTodSrcTable 1 }
ZxAnSyncTimeTodSrcEntry ::= SEQUENCE {
zxAnSyncTimeTodSrcRack Integer32,
zxAnSyncTimeTodSrcShelf Integer32,
zxAnSyncTimeTodSrcSlot Integer32,
zxAnSyncTimeTodSrcPort Integer32,
zxAnSyncTimeTodSrcSignalType INTEGER,
zxAnSyncTimeTodSrcYearAdjust Integer32,
zxAnSyncTimeTodSrcPortStatus INTEGER,
zxAnSyncTimeTodSrcRowStatus RowStatus
}
zxAnSyncTimeTodSrcRack OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This object indicates the rack number."
::= { zxAnSyncTimeTodSrcEntry 1 }
zxAnSyncTimeTodSrcShelf OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This object indicates the shelf number."
::= { zxAnSyncTimeTodSrcEntry 2 }
zxAnSyncTimeTodSrcSlot OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This object indicates the slot number."
::= { zxAnSyncTimeTodSrcEntry 3 }
zxAnSyncTimeTodSrcPort OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This object indicates the port number."
::= { zxAnSyncTimeTodSrcEntry 4 }
zxAnSyncTimeTodSrcSignalType OBJECT-TYPE
SYNTAX INTEGER
{
gps(1),
chinaMobile(2),
chinaUnicom(3),
chinaTelecom(4)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION "The signal type of TOD signal source."
::= { zxAnSyncTimeTodSrcEntry 5 }
zxAnSyncTimeTodSrcYearAdjust OBJECT-TYPE
SYNTAX Integer32(0..2050)
UNITS "year"
MAX-ACCESS read-create
STATUS current
DESCRIPTION "The year adjustment value of TOD signal source.
It is valid only for the 'gps' signal type."
DEFVAL { 0 }
::= { zxAnSyncTimeTodSrcEntry 6 }
zxAnSyncTimeTodSrcPortStatus OBJECT-TYPE
SYNTAX INTEGER
{
none(1),
normal(2),
signalLos(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The TOD signal source port status."
::= { zxAnSyncTimeTodSrcEntry 7 }
zxAnSyncTimeTodSrcRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The row status of this entry."
::= { zxAnSyncTimeTodSrcEntry 30 }
-------------------------------------------------------------------------------
-- 5. Synchronization Time Management: zxAnSyncTimeOutputPortTable
-------------------------------------------------------------------------------
zxAnSyncTimeOutputPortTable OBJECT-TYPE
SYNTAX SEQUENCE OF ZxAnSyncTimeOutputPortEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "This table includes 1PPS and TOD signal output ports
information in NE equipment."
::= { zxAnSyncTimeClkSrcMgmt 5 }
zxAnSyncTimeOutputPortEntry OBJECT-TYPE
SYNTAX ZxAnSyncTimeOutputPortEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An entry in zxAnSyncTimeOutputPortTable."
INDEX {zxAnSyncTimeOutputRack,zxAnSyncTimeOutputShelf,
zxAnSyncTimeOutputSlot,zxAnSyncTimeOutputPort}
::= { zxAnSyncTimeOutputPortTable 1 }
ZxAnSyncTimeOutputPortEntry ::= SEQUENCE {
zxAnSyncTimeOutputRack Integer32,
zxAnSyncTimeOutputShelf Integer32,
zxAnSyncTimeOutputSlot Integer32,
zxAnSyncTimeOutputPort Integer32,
zxAnSyncTimeOutputPortEnable INTEGER,
zxAnSyncTimeOutputPortPhaseAdjus Integer32,
zxAnSyncTimeOutputPortRowStatus RowStatus
}
zxAnSyncTimeOutputRack OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This object indicates the rack number."
::= { zxAnSyncTimeOutputPortEntry 1 }
zxAnSyncTimeOutputShelf OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This object indicates the shelf number."
::= { zxAnSyncTimeOutputPortEntry 2 }
zxAnSyncTimeOutputSlot OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This object indicates the slot number."
::= { zxAnSyncTimeOutputPortEntry 3 }
zxAnSyncTimeOutputPort OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This object indicates the port number."
::= { zxAnSyncTimeOutputPortEntry 4 }
zxAnSyncTimeOutputPortEnable OBJECT-TYPE
SYNTAX INTEGER
{
enable(1),
disable(2)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION "Enables or disables the output port of
1PPS and TOD signal."
DEFVAL { enable }
::= { zxAnSyncTimeOutputPortEntry 5 }
zxAnSyncTimeOutputPortPhaseAdjus OBJECT-TYPE
SYNTAX Integer32(-1000000..1000000)
UNITS "ns"
MAX-ACCESS read-create
STATUS current
DESCRIPTION "The phase adjustment value.
It is valid only for the 1PPS signal."
DEFVAL { 0 }
::= { zxAnSyncTimeOutputPortEntry 6 }
zxAnSyncTimeOutputPortRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The row status of this entry."
::= { zxAnSyncTimeOutputPortEntry 30 }