-- phyWtnRadio.mib
|
|
-- MIB generated by MG-SOFT Visual MIB Builder Version 2.1 Build 205
|
|
-- Wednesday, August 22, 2001 at 02:16:01
|
|
--
|
|
|
|
ZHONE-PHY-WTN-RADIO-MIB DEFINITIONS ::= BEGIN
|
|
|
|
IMPORTS
|
|
InterfaceIndex
|
|
FROM IF-MIB
|
|
SnmpAdminString
|
|
FROM SNMP-FRAMEWORK-MIB
|
|
Integer32, Gauge32, OBJECT-TYPE, MODULE-IDENTITY, NOTIFICATION-TYPE
|
|
FROM SNMPv2-SMI
|
|
TruthValue, TimeStamp
|
|
FROM SNMPv2-TC
|
|
SkyZhoneScientificNotation, SkyZhoneRadioChannelNumber
|
|
FROM ZHONE-RADIO-TC-MIB
|
|
zhoneRadio, zhoneModules
|
|
FROM Zhone
|
|
ZhoneAdminString
|
|
FROM Zhone-TC;
|
|
|
|
|
|
--
|
|
--
|
|
zhonePhyWtnRadio MODULE-IDENTITY
|
|
LAST-UPDATED "190011031129Z"
|
|
ORGANIZATION
|
|
"Zhone Technologies, Inc."
|
|
CONTACT-INFO
|
|
" Postal:
|
|
Zhone Technologies, Inc.
|
|
@ Zhone Way
|
|
7001 Oakport Street
|
|
Oakland, CA 94621
|
|
USA
|
|
Toll-Free: +1 877-ZHONE20 (+1 877-946-6320)
|
|
Tel: +1-510-777-7000
|
|
Fax: +1-510-777-7001
|
|
E-mail: support@zhone.com
|
|
|
|
Zhone Technologies, Inc.
|
|
Wireless Group
|
|
120 Stony Point Rd
|
|
Suite 140
|
|
Santa Rosa, CA 95401
|
|
707 206 3600"
|
|
DESCRIPTION
|
|
"Module for radio provisioning and status."
|
|
REVISION "200107111300Z"
|
|
DESCRIPTION
|
|
"V01.04.01 - Use SkyZhoneScientificNotation rather
|
|
than SinglePrecision Floating point
|
|
format."
|
|
REVISION "200106071414Z"
|
|
DESCRIPTION
|
|
"V01.03.01 - add ODU loopback"
|
|
REVISION "200105181002Z"
|
|
DESCRIPTION
|
|
"V01.03.00 - Generalize for all SkyZhone products."
|
|
REVISION "200011240818Z"
|
|
DESCRIPTION
|
|
"V01.02.00 - Support traps."
|
|
REVISION "200011211535Z"
|
|
DESCRIPTION
|
|
"V01.00.01 - Add DDL markups."
|
|
REVISION "200011030944Z"
|
|
DESCRIPTION
|
|
"V01.00.00 - Initial Revision"
|
|
::= { zhoneModules 106 }
|
|
|
|
|
|
|
|
--
|
|
-- Node definitions
|
|
--
|
|
|
|
-- For use of radio interface regarding the ifTable,
|
|
-- see the zhoneRadio-TC.mib.
|
|
wtnConfigTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF WtnConfigEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Radio, modem and ODU configuration information. An entry
|
|
is automatically created for each radio/modem/ODU
|
|
interface."
|
|
::= { zhoneRadio 1 }
|
|
|
|
wtnConfigEntry OBJECT-TYPE
|
|
SYNTAX WtnConfigEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Configuration entries"
|
|
INDEX { wtnRadioIfIndex }
|
|
::= { wtnConfigTable 1 }
|
|
|
|
WtnConfigEntry ::=
|
|
SEQUENCE {
|
|
wtnRadioIfIndex
|
|
InterfaceIndex,
|
|
wtnActiveChannelNumber
|
|
SkyZhoneRadioChannelNumber,
|
|
wtnActiveTransmitFrequency
|
|
SkyZhoneScientificNotation,
|
|
wtnStandbyChannelNumber
|
|
SkyZhoneRadioChannelNumber,
|
|
wtnStandbyTransmitFrequency
|
|
SkyZhoneScientificNotation,
|
|
wtnAutoChannelSwitchEnable
|
|
TruthValue,
|
|
wtnChannelSeparation
|
|
INTEGER,
|
|
wtnRadioAmplifiersEnable
|
|
TruthValue,
|
|
wtnRxBERThresh
|
|
SkyZhoneScientificNotation,
|
|
wtnRxBERHysteresisWindow
|
|
SkyZhoneScientificNotation,
|
|
wtnAntennaSize
|
|
INTEGER,
|
|
wtnIduOduCableLength
|
|
Integer32,
|
|
wtnRssiThresh
|
|
Integer32,
|
|
wtnRssiHysteresisWindow
|
|
Integer32,
|
|
wtnTrapsEnable
|
|
TruthValue,
|
|
wtnOduLoopback
|
|
INTEGER,
|
|
wtnOduIdentifier
|
|
SnmpAdminString,
|
|
wtnTxLevel
|
|
Integer32
|
|
}
|
|
|
|
wtnRadioIfIndex OBJECT-TYPE
|
|
SYNTAX InterfaceIndex
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object should be made equal to the Ifindex used for
|
|
the radio interface."
|
|
::= { wtnConfigEntry 1 }
|
|
|
|
--
|
|
wtnActiveChannelNumber OBJECT-TYPE
|
|
SYNTAX SkyZhoneRadioChannelNumber
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Assigns one of N allowed frequency pairs for the radio
|
|
transmitter and reciever as described in zhoneRadio-TC.mib.
|
|
|
|
5.7Ghz family (sysObjId) systems:
|
|
---------------------------------
|
|
Writing to this value will change the current operating frequency.
|
|
The active channel is the default channel used on power up.
|
|
|
|
The channel is switched at the near end, and if possible, also at
|
|
the far end, towards minimizing link down time.
|
|
|
|
Every time the active channel number changes BITS WILL BE DROPPED.
|
|
In poor conditions there is a risk that the new frequency assignment
|
|
will fare more poorly. The user should expect alarms where the facility
|
|
is terminated until the nodes re-sync.
|
|
|
|
If a new active channel number is equal to the current value of
|
|
active channel, the command will have no effect and no error message will result.
|
|
|
|
|
|
Allowed range of allowed values: 0 - 17
|
|
|
|
This value will read back the current active channel.
|
|
|
|
Note: if this value is changed to a new active channel number,
|
|
and the system can not establish a radio link at this channel,
|
|
the system may automatically switch to the standby channel, if
|
|
wtnAutoChannelSwitchEnable is true(1), and the value of
|
|
wtnStandbyChannelNumber is neither the same channel number nor zero.
|
|
|
|
23Ghz family (sysObjId) systems:
|
|
-------------------------------
|
|
This variable is not used and so should not be presented to user.
|
|
Use direct frequency assignments instead.
|
|
See wtnActiveTransmitFrequency."
|
|
::= { wtnConfigEntry 2 }
|
|
|
|
wtnActiveTransmitFrequency OBJECT-TYPE
|
|
SYNTAX SkyZhoneScientificNotation
|
|
UNITS "Hz"
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Current transmit frequency. As described in zhoneRadio-TC.mib.
|
|
|
|
|
|
23Ghz family: ( according to sysObjId )
|
|
-------------------------------------------
|
|
The transmit frequency is entered as a floating point number in Mhz,
|
|
for example, 23565.5 for 23.5655Ghz.
|
|
Note: receive frequency will also be affected by this parameter.
|
|
|
|
The resulting receive frequency will be simultaneously set to
|
|
this value +/- wtnChannelSeparation (plus or minus depending upon
|
|
whether the unit is an A or B type ODU.)
|
|
|
|
If the frequency entered or the calulated receive frequency
|
|
outside the range of the unit, an error will be returned and the
|
|
value left unchanged.
|
|
|
|
If a new active frequency is equal to the current value frequency,
|
|
the command will have no effect and no error message will result.
|
|
|
|
Every time the active frequency changes BITS WILL BE DROPPED.
|
|
In poor conditions there is a risk that the new frequency assignment
|
|
will fare more poorly. The user should expect alarms where the facility
|
|
is terminated until the nodes re-sync.
|
|
|
|
If the link is operational, the new frequencies will be changed
|
|
at the opposite end before the values at the local end are changed
|
|
in an attempt to minimize payload data loss.
|
|
|
|
5.7Ghz family of systems (according to sysObjId )
|
|
-------------------------------------------------
|
|
Value will reflect the frequency of the currently
|
|
active channel (wtnActiveChannelNumber).
|
|
Writing to this variable will have no effect."
|
|
::= { wtnConfigEntry 3 }
|
|
|
|
--
|
|
wtnStandbyChannelNumber OBJECT-TYPE
|
|
SYNTAX SkyZhoneRadioChannelNumber
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Assigns one of N allowed standby frequency pairs to the radio
|
|
transmitter and reciever as described in zhoneRadio-TC.mib.
|
|
|
|
5.7Ghz family (sysObjId) systems:
|
|
---------------------------------
|
|
Selection of one of N possible frequency pairs for the
|
|
standby radio transmitter reciever.
|
|
|
|
The Standby channel is the channel automatically switched to
|
|
in the event of failure of the current active channel, for example,
|
|
due to radio inteference. Automatic Switching must be enabled for
|
|
the standby channel to be switched to by setting wtnAutoChannelSwitchEnable
|
|
to true.
|
|
|
|
If the standby channel is assigned a value of zero (0), the automatic
|
|
switch to standby feature is effectively disabled, regardless of
|
|
the value of wtnAutoChannelSwitchEnable.
|
|
|
|
The channel is switched at the near end, and if possible, also at
|
|
the far end, towards minimizing link down time.
|
|
|
|
|
|
Allowed range of allowed values (see zhoneRadio-TC.mib ): 0 - 17
|
|
|
|
This value will read back the current standby channel.
|
|
|
|
Operation -
|
|
If a switch-to-standby channel event occurs, the active channel
|
|
number and the standby channel number swap values. For example,
|
|
|
|
before a radio failure: active channel = 1,
|
|
standby channel = 7, and
|
|
automatic channel switching is enabled.
|
|
|
|
After a radio failure on channel 1:
|
|
active channel = 7,
|
|
standby channel = 1, and
|
|
automatic channel switching is enabled.
|
|
|
|
If both channels fail to operate, the system will bounce back
|
|
and forth between the active and standby channels until the radio
|
|
link is re-established.
|
|
|
|
|
|
23Ghz family sysObjId systems:
|
|
-------------------------------
|
|
This variable is not used and so should not be presented to user.
|
|
Use direct frequency assignments instead.
|
|
See wtnStandbyTransmitFrequency.
|
|
"
|
|
::= { wtnConfigEntry 4 }
|
|
|
|
wtnStandbyTransmitFrequency OBJECT-TYPE
|
|
SYNTAX SkyZhoneScientificNotation
|
|
UNITS "Hz"
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Standby Transmit frequency as described in zhoneRadio-TC.mib.
|
|
|
|
|
|
23Ghz family: ( according to sysObjId )
|
|
-------------------------------------------
|
|
If auto-switching is enabled, the
|
|
frequency shown will be used in the event the currently active
|
|
frequency fails due to low RSSI, or high BER. Note the switch
|
|
will occur only if wtnAutoChannelSwitchEnable is true(1).
|
|
|
|
The transmit frequency is entered as a floating point number in Mhz,
|
|
for example, 23565.5 for 23.5655Ghz.
|
|
|
|
If the frequency entered or the calulated receive frequency
|
|
outside the range of the unit, an error will be returned and the
|
|
value left unchanged.
|
|
|
|
If the link is operational, the new standby frequencies will be changed
|
|
at the opposite end before the values at the local end are changed.
|
|
|
|
|
|
5.7Ghz family: (according to sysObjId )
|
|
-----------------------------------------
|
|
Value will reflect the frequency of the currently
|
|
active channel (wtnStandbyChannelNumber).
|
|
Writing to this variable will have no effect."
|
|
::= { wtnConfigEntry 5 }
|
|
|
|
--
|
|
wtnAutoChannelSwitchEnable OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"true(1) - allows radio to automatically switch
|
|
to the standby channel in case of active channel
|
|
interference.
|
|
|
|
false(2) - inhibits radio from automatically
|
|
switching to the standby channel.
|
|
|
|
The default value is false(2)."
|
|
::= { wtnConfigEntry 6 }
|
|
|
|
wtnChannelSeparation OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
na(0),
|
|
s1232MHz(1),
|
|
s1200MHz(2),
|
|
s1008MHz(3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"23Ghz family (sysObjId) systems:
|
|
---------------------------------
|
|
Channel separation - the fixed difference between transmit
|
|
and receive frequency.
|
|
|
|
Only three values are allowed: s1232MHz(1), s1200MHz,
|
|
and s1008MHz.
|
|
|
|
This value is used to automatically calculate the receive
|
|
frequency, when the transmit frequency is entered.
|
|
|
|
Default value: s1232Mhz(1)
|
|
|
|
|
|
5.7Ghz family (sysObjId) systems:
|
|
---------------------------------
|
|
Not used. ( Internally fixed at 475MHz fixed ).
|
|
|
|
Default value: na(0)"
|
|
::= { wtnConfigEntry 7 }
|
|
|
|
--
|
|
wtnRadioAmplifiersEnable OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"true(1) - Enables amplifiers for transmitter and receiver.
|
|
The radio will begin transmitting and receiving data. If the ODU
|
|
is looped back, unable to lock onto a signal, or the ODU equipment
|
|
has failed, the enable command will return an error trap and
|
|
the amplifier enable state will transition to disableAmplifiers(2).
|
|
|
|
|
|
false(2) - shuts down the transmit and receive amplifiers of the ODU.
|
|
This will cause the link to go down. Payload will be dropped.
|
|
|
|
|
|
When the amplifiers are turned off, the active and standby
|
|
channel assignments may be freely changed, if necessary,
|
|
but notification of such changes to the far end will not be done
|
|
automatically. That is, channel assignments made when the
|
|
amplifiers are disabled must be done manually at each node -
|
|
near end and far end.
|
|
|
|
Default value after power up is false(2).
|
|
|
|
"
|
|
::= { wtnConfigEntry 8 }
|
|
|
|
--
|
|
wtnRxBERThresh OBJECT-TYPE
|
|
SYNTAX SkyZhoneScientificNotation
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Set point of BER alarm. When the modem BER estimate
|
|
is higher than this value, a modem BER alarm will occur.
|
|
The BER over threshold Causes trap wtnBerAlarm to be emitted.
|
|
The alarm will stay present until the modem BER estimate
|
|
is lower than this set point less the hysteresis window
|
|
wtnMdmRxBERHysteresisWindow.
|
|
|
|
A value of 0 disables the BER threshold alarm.
|
|
|
|
Allowed range is 1.0e-1 to 1.0e-12.
|
|
|
|
|
|
BER is assumed accumulated over a second."
|
|
::= { wtnConfigEntry 9 }
|
|
|
|
--
|
|
wtnRxBERHysteresisWindow OBJECT-TYPE
|
|
SYNTAX SkyZhoneScientificNotation
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"After a wtnBerAlarm trap is sent, it is revoked using the same trap with
|
|
the condition flag set to false when the modem BER estimate is lower
|
|
than the set point wtnModemRxBERThresh less this value.
|
|
|
|
Valid values are 0, and the range from 1.0e-1 to 1.0e-12.
|
|
|
|
A value of 0 indicates no hysteresis.
|
|
|
|
BER is assumed accumulated over the last second."
|
|
::= { wtnConfigEntry 10 }
|
|
|
|
--
|
|
wtnAntennaSize OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
oneFoot(1),
|
|
twoFeet(2),
|
|
fourFeet(4),
|
|
sixFeet(6)
|
|
}
|
|
UNITS "feet"
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Initial power of transmitter is based upon antenna diameter.
|
|
|
|
oneFoot(1) - a one foot dish
|
|
twoFeet(2) - a two foot dish
|
|
fourFeet(4) - a four foot dish
|
|
sixFeet(6) - a six foot dish
|
|
|
|
FCC mandates a maximimum EIRP (Effective Isotropic
|
|
Radiated Power) level, which is directly dependent
|
|
upon antenna size.
|
|
|
|
The system will use antenna size to determine a
|
|
power level in accordance to maxmimum EIRP.
|
|
|
|
5.7Ghz family
|
|
-------------------
|
|
The equipment is shipped with a dish that
|
|
is one of 3 sizes:
|
|
|
|
twoFeet(2) - a two foot dish
|
|
fourFeet(4) - a four foot dish
|
|
sixFeet(6) - a six foot dish
|
|
|
|
Default value sixFeet(3).
|
|
|
|
|
|
23Ghz family
|
|
-------------------
|
|
The equipment is shipped with a dish that
|
|
is one of 2 sizes:
|
|
|
|
oneFoot(1) - a one foot dish
|
|
twoFeet(2) - a two foot dish
|
|
|
|
Default value: twoFeet(2).
|
|
|
|
"
|
|
DEFVAL { sixFeet }
|
|
::= { wtnConfigEntry 11 }
|
|
|
|
--
|
|
wtnIduOduCableLength OBJECT-TYPE
|
|
SYNTAX Integer32 (0..300)
|
|
UNITS "feet"
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The length of the coaxial cable between the Indoor
|
|
Unit and the Outdoor Unit.
|
|
|
|
Used internally to compensate for the coaxial cable's
|
|
natural attenuation of the signal.
|
|
|
|
This cable is cut to its appropriate length when the system
|
|
is installed.
|
|
|
|
Default value: 0 feet."
|
|
DEFVAL { 0 }
|
|
::= { wtnConfigEntry 12 }
|
|
|
|
wtnRssiThresh OBJECT-TYPE
|
|
SYNTAX Integer32 (-99..-30)
|
|
UNITS "dB"
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Set point of RSSI thresholdalarm. When the ODU RSSI estimate
|
|
is lower than this value, a wtnRssiDeviation trap will be emitted.
|
|
When the ODU RSSI estimate is higher than this set point
|
|
plus the hysteresis window wtnOduRxRSSIHysteresisWindow, the same
|
|
trap will be re-emitted with condition = false..
|
|
|
|
|
|
Receive signal strength (RSSI) reported by near end
|
|
ODU.
|
|
|
|
Typical values range from -95dB to -30dB.
|
|
Tyipcal nominal value is -60dB."
|
|
DEFVAL { -80 }
|
|
::= { wtnConfigEntry 13 }
|
|
|
|
--
|
|
wtnRssiHysteresisWindow OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "dB"
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"After a wtnRssiDeviation Trap is sent, an the trap is re-emitted
|
|
with the condition flag set to false when the ODU RSSI
|
|
estimate is higher than the set point wtnOduRxRSSIThresh plus this value.
|
|
|
|
Typical value of window size is 10dB."
|
|
DEFVAL { 10 }
|
|
::= { wtnConfigEntry 14 }
|
|
|
|
--
|
|
wtnTrapsEnable OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"When true(1), radio traps may be emitted.
|
|
When false(2), radio traps will be absorbed.
|
|
|
|
Default value is true(1) = enabled."
|
|
::= { wtnConfigEntry 15 }
|
|
|
|
wtnOduLoopback OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
loopbackOn(1),
|
|
loopbackOff(2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"loopbackOn(1) - engages the loopback function at the ODU (outdoor unit).
|
|
Data normally transmitted by the radio is instead returned to the IDU
|
|
(indoor unit). This is useful to check the integrity of the IDU, the
|
|
integrity of the cable connecting IDU to ODU, and of some portions
|
|
of ODU circuitry.
|
|
ifAdminStatus must be in 'testing' mode for loopbackOn to be accepted.
|
|
Once the loopback is turned on verify that there is no radio alarm
|
|
condition. Also, any line data received on the line interface
|
|
(DS3, STM-1, E1, etc) will be looped back and transmitted to it.
|
|
|
|
|
|
loopbackOff(2) - disengages the loopback function at the ODU.
|
|
Causes the radio to re-acquire the signal from the far end, if any."
|
|
::= { wtnConfigEntry 16 }
|
|
|
|
--
|
|
wtnOduIdentifier OBJECT-TYPE
|
|
SYNTAX SnmpAdminString
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Textual description of ODU.
|
|
This string typically identifies the location of antenna."
|
|
::= { wtnConfigEntry 17 }
|
|
|
|
--
|
|
wtnTxLevel OBJECT-TYPE
|
|
SYNTAX Integer32 (0..45)
|
|
UNITS "dB"
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Desired transmitter signal strength (TSSI) at antenna.
|
|
Note: Accuracy decreases as power levels decrease below 20dBm.
|
|
FCC maximum power allowed is +30dBm. "
|
|
DEFVAL { 0 }
|
|
::= { wtnConfigEntry 18 }
|
|
|
|
wtnStatusTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF WtnStatusEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Contains the status of the Radio, ODU and Modem."
|
|
::= { zhoneRadio 2 }
|
|
|
|
wtnStatusEntry OBJECT-TYPE
|
|
SYNTAX WtnStatusEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Entries for radio, ODU and modem status."
|
|
AUGMENTS { wtnConfigEntry }
|
|
::= { wtnStatusTable 1 }
|
|
|
|
WtnStatusEntry ::=
|
|
SEQUENCE {
|
|
wtnCriticalAlarmStatus
|
|
BITS,
|
|
wtnCriticalAlarmStatusLastChange
|
|
TimeStamp,
|
|
wtnMinorAlarmStatus
|
|
BITS,
|
|
wtnMinorAlarmStatusLastChange
|
|
TimeStamp,
|
|
wtnOduTemperature
|
|
Integer32,
|
|
wtnReceiveFrequency
|
|
SkyZhoneScientificNotation
|
|
}
|
|
|
|
--
|
|
wtnCriticalAlarmStatus OBJECT-TYPE
|
|
SYNTAX BITS
|
|
{
|
|
rssiDeviation(0),
|
|
iduOOL(1),
|
|
oduTempAlert(2),
|
|
rxBerAlarm(3),
|
|
rxEbnoAlarm(4),
|
|
unused5(5),
|
|
unused6(6),
|
|
unused7(7),
|
|
iduEquipFail(8),
|
|
oduEquipFail(9),
|
|
iduOduLinkFail(10),
|
|
mcChannelFail(11),
|
|
unused12(12),
|
|
unused13(13),
|
|
unused14(14),
|
|
serviceAffected(15)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Current radio alarm status details.
|
|
|
|
|
|
BIT Hex Decimal BIT NAME
|
|
Number Value Value
|
|
------ ------ ------- ----------------------
|
|
0 0x01 1 RSSI_DEVIATION
|
|
1 0x02 2 IDU_OOL
|
|
2 0x04 4 ODU_TEMP_ALERT
|
|
3 0x08 8 RX_BER_ALARM
|
|
4 0x10 16 RX_EBNO_ALARM
|
|
5 0x20 32 (reserved)
|
|
6 0x40 64 (reserved)
|
|
7 0x80 128 (reserved)
|
|
8 0x100 256 IDU_EQUIP_FAIL
|
|
9 0x200 512 ODU_EQUIP_FAIL
|
|
10 0x400 1024 IDU_ODU_LINK_FAIL
|
|
11 0x800 2048 MC_CHANNEL_FAIL
|
|
12 0x1000 4096 (reserved)
|
|
13 0x2000 8192 (reserved)
|
|
14 0x4000 16384 (reserved)
|
|
15 0x8000 32768 SERVICE_AFFECTED
|
|
|
|
IDU_EQUIP_FAIL - can be caused by:
|
|
power supply failure, watchdog timeout, or other internal
|
|
failure on indoor unit.
|
|
|
|
IDU_ODU_LINK_FAIL - can be caused by:
|
|
IDU/ODU cable failure, bad connection, or equipment failure
|
|
|
|
IDU_OOL - can be caused by:
|
|
intermittent loss of lock of internal clocks
|
|
|
|
MC_CHANNEL_FAIL - can be caused by:
|
|
Signal path (air) degradation, or internal equipment failure
|
|
on near end or far end node.
|
|
|
|
ODU_EQUIP_FAIL - can be caused by:
|
|
Loss of frequency lock, loss of clock reference, power fault,
|
|
excessive transmitter power, signal path degradation,
|
|
frequency drift, or internal failure of equipment in outdoor
|
|
unit.
|
|
|
|
ODU_TEMP_ALERT - can be caused by:
|
|
Operating temperature too high or too low. Allowable range
|
|
of operating temperatures ( in ODU ) are -40C to +65C.
|
|
|
|
RSSI_DEVIATION - can be caused by:
|
|
signal path (air) degradation, excessive heat buildup at ODU,
|
|
or frequency drift.
|
|
|
|
RX_BER_ALARM - can be caused by:
|
|
RF noise burst, fade burst, interference, or internal equipment
|
|
failure.
|
|
|
|
RX_EBNO_ALARM - can be caused by:
|
|
Fade, noise burst, or internal equipment stress.
|
|
|
|
SERVICE_AFFECTED - indicates a predicted loss of data
|
|
or quality of service in transport due to any of the
|
|
above conditions."
|
|
::= { wtnStatusEntry 1 }
|
|
|
|
wtnCriticalAlarmStatusLastChange OBJECT-TYPE
|
|
SYNTAX TimeStamp
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Time Stamp of last change of critical alarm status
|
|
wtnRadioCriticalAlmStatus. "
|
|
::= { wtnStatusEntry 2 }
|
|
|
|
wtnMinorAlarmStatus OBJECT-TYPE
|
|
SYNTAX BITS
|
|
{
|
|
rssiDeviation(0),
|
|
iduOOL(1),
|
|
oduTempAlert(2),
|
|
rxBerAlarm(3),
|
|
rxEbnoAlarm(4),
|
|
unused5(5),
|
|
unused6(6),
|
|
unused7(7),
|
|
iduEquipFail(8),
|
|
oduEquipFail(9),
|
|
iduOduLinkFail(10),
|
|
mcChannelFail(11),
|
|
unused12(12),
|
|
unused13(13),
|
|
unused14(14),
|
|
serviceAffected(15)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Current radio alarm status details.
|
|
|
|
BIT Hex Decimal BIT NAME
|
|
Number Value Value
|
|
------ ------ ------- ----------------------
|
|
0 0x01 1 RSSI_DEVIATION
|
|
1 0x02 2 IDU_OOL
|
|
2 0x04 4 ODU_TEMP_ALERT
|
|
3 0x08 8 RX_BER_ALARM
|
|
4 0x10 16 RX_EBNO_ALARM
|
|
5 0x20 32 (reserved)
|
|
6 0x40 64 (reserved)
|
|
7 0x80 128 (reserved)
|
|
8 0x100 256 IDU_EQUIP_FAIL
|
|
9 0x200 512 ODU_EQUIP_FAIL
|
|
10 0x400 1024 IDU_ODU_LINK_FAIL
|
|
11 0x800 2048 MC_CHANNEL_FAIL
|
|
12 0x1000 4096 (reserved)
|
|
13 0x2000 8192 (reserved)
|
|
14 0x4000 16384 (reserved)
|
|
15 0x8000 32768 SERVICE_AFFECTED
|
|
|
|
IDU_EQUIP_FAIL - can be caused by:
|
|
power supply failure, watchdog timeout, or other internal
|
|
failure on indoor unit.
|
|
|
|
IDU_ODU_LINK_FAIL - can be caused by:
|
|
IDU/ODU cable failure, bad connection, or equipment failure
|
|
|
|
IDU_OOL - can be caused by:
|
|
intermittent loss of lock of internal clocks
|
|
|
|
MC_CHANNEL_FAIL - can be caused by:
|
|
Signal path (air) degradation, or internal equipment failure
|
|
on near end or far end node.
|
|
|
|
ODU_EQUIP_FAIL - can be caused by:
|
|
Loss of frequency lock, loss of clock reference, power fault,
|
|
excessive transmitter power, signal path degradation,
|
|
frequency drift, or internal failure of equipment in outdoor
|
|
unit.
|
|
|
|
ODU_TEMP_ALERT - can be caused by:
|
|
Operating temperature too high or too low. Allowable range
|
|
of operating temperatures ( in ODU ) are -40C to +65C.
|
|
|
|
RSSI_DEVIATION - can be caused by:
|
|
signal path (air) degradation, excessive heat buildup at ODU,
|
|
or frequency drift.
|
|
|
|
RX_BER_ALARM - can be caused by:
|
|
RF noise burst, fade burst, interference, or internal equipment
|
|
failure.
|
|
|
|
RX_EBNO_ALARM - can be caused by:
|
|
Fade, noise burst, or internal equipment stress.
|
|
|
|
|
|
The SERVICE_AFFECTING bit should always = 0 on this variable
|
|
because, by definition, minor alarms may not affect service.
|
|
"
|
|
::= { wtnStatusEntry 3 }
|
|
|
|
wtnMinorAlarmStatusLastChange OBJECT-TYPE
|
|
SYNTAX TimeStamp
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Time Stamp of last change of minor alarm status
|
|
wtnRadioMinorAlmStatus."
|
|
::= { wtnStatusEntry 4 }
|
|
|
|
--
|
|
wtnOduTemperature OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Current temperature measured at local outdoor unit, in
|
|
degrees Celsius (Centigrade)."
|
|
::= { wtnStatusEntry 5 }
|
|
|
|
wtnReceiveFrequency OBJECT-TYPE
|
|
SYNTAX SkyZhoneScientificNotation
|
|
UNITS "Hz"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Current frequency at which radio receiver is set."
|
|
::= { wtnStatusEntry 6 }
|
|
|
|
wtnInfoTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF WtnInfoEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Table augments the wtnConfigTable"
|
|
::= { zhoneRadio 3 }
|
|
|
|
wtnInfoEntry OBJECT-TYPE
|
|
SYNTAX WtnInfoEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Device information entries for the radio, modem and ODU."
|
|
AUGMENTS { wtnConfigEntry }
|
|
::= { wtnInfoTable 1 }
|
|
|
|
WtnInfoEntry ::=
|
|
SEQUENCE {
|
|
wtnOduSerialNumber
|
|
ZhoneAdminString,
|
|
wtnOduMfgCLEICode
|
|
ZhoneAdminString
|
|
}
|
|
|
|
--
|
|
wtnOduSerialNumber OBJECT-TYPE
|
|
SYNTAX ZhoneAdminString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Manufacturing Serial Number for Outdoor Unit.
|
|
Format of the serial number is XXXXX, where X = 0 to F."
|
|
::= { wtnInfoEntry 1 }
|
|
|
|
--
|
|
wtnOduMfgCLEICode OBJECT-TYPE
|
|
SYNTAX ZhoneAdminString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"CLEI code for Outdoor Unit."
|
|
::= { wtnInfoEntry 2 }
|
|
|
|
wtnSnapshotTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF WtnSnapshotEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Table to collect statistics at radio demodulator of
|
|
wireless transport node."
|
|
::= { zhoneRadio 4 }
|
|
|
|
wtnSnapshotEntry OBJECT-TYPE
|
|
SYNTAX WtnSnapshotEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Entry into wireless transport local radio status table.
|
|
No rows may be added to this table."
|
|
AUGMENTS { wtnConfigEntry }
|
|
::= { wtnSnapshotTable 1 }
|
|
|
|
WtnSnapshotEntry ::=
|
|
SEQUENCE {
|
|
wtnRSSI
|
|
Integer32,
|
|
wtnTSSI
|
|
Integer32,
|
|
wtnRxBerFloat
|
|
SkyZhoneScientificNotation,
|
|
wtnRcvEbNoFloat
|
|
SkyZhoneScientificNotation
|
|
}
|
|
|
|
--
|
|
wtnRSSI OBJECT-TYPE
|
|
SYNTAX Integer32 (-90..0)
|
|
UNITS "dBm"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Current Received Signal Strength in dB as registered at
|
|
the near end Outdoor Unit. This number is updated about once per
|
|
second.
|
|
|
|
Typical values range from -95dB to -30dB.
|
|
Tyipcal nominal value is -60dB."
|
|
::= { wtnSnapshotEntry 1 }
|
|
|
|
wtnTSSI OBJECT-TYPE
|
|
SYNTAX Integer32 (0..45)
|
|
UNITS "dBm"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Estimated transmitter signal strength (TSSI) at antenna.
|
|
Note: maximum level allowed by FCC is 30dBm."
|
|
::= { wtnSnapshotEntry 2 }
|
|
|
|
--
|
|
wtnRxBerFloat OBJECT-TYPE
|
|
SYNTAX SkyZhoneScientificNotation
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Current received BER at local Indoor Unit demodulator over
|
|
the previous 250ms."
|
|
::= { wtnSnapshotEntry 3 }
|
|
|
|
--
|
|
wtnRcvEbNoFloat OBJECT-TYPE
|
|
SYNTAX SkyZhoneScientificNotation
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Current local demodulator (rcvd) Energy-bit per noise.
|
|
Conveys energy in each bit as compared to energy in noise."
|
|
::= { wtnSnapshotEntry 4 }
|
|
|
|
wtnTrapData OBJECT IDENTIFIER ::= { zhoneRadio 5 }
|
|
|
|
wtnTraps OBJECT IDENTIFIER ::= { wtnTrapData 0 }
|
|
|
|
wtnIduEquipFailCritical NOTIFICATION-TYPE
|
|
OBJECTS { wtnTrapCondition, wtnServiceAffected }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Critical indoor equipment failure trap.
|
|
Can be caused by:
|
|
power supply failure, watchdog timeout, or other internal
|
|
failure on indoor unit."
|
|
::= { wtnTraps 1 }
|
|
|
|
wtnIduEquipFail NOTIFICATION-TYPE
|
|
OBJECTS { wtnTrapCondition, wtnServiceAffected }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Non-critical indoor equipment failure trap.
|
|
Can be caused by:
|
|
spurious power supply failure,
|
|
or other temporary internal failure on indoor unit."
|
|
::= { wtnTraps 2 }
|
|
|
|
wtnIduOduLinkFailCritical NOTIFICATION-TYPE
|
|
OBJECTS { wtnTrapCondition, wtnServiceAffected }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Critical failure of IDU to ODU communications link trap.
|
|
can be caused by:
|
|
IDU/ODU cable failure,
|
|
bad connection, or
|
|
equipment failure."
|
|
::= { wtnTraps 3 }
|
|
|
|
wtnIduOduLinkFail NOTIFICATION-TYPE
|
|
OBJECTS { wtnTrapCondition, wtnServiceAffected }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Intermittent failure of IDU to ODU communications link trap.
|
|
can be caused by:
|
|
IDU/ODU cable failure,
|
|
bad connection,
|
|
or spurious equipment failure."
|
|
::= { wtnTraps 4 }
|
|
|
|
wtnIduOutOfLockCritical NOTIFICATION-TYPE
|
|
OBJECTS { wtnTrapCondition, wtnServiceAffected }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Permanent or persistant loss of lock of internal clocks
|
|
in indoor unit."
|
|
::= { wtnTraps 5 }
|
|
|
|
wtnIduOutOfLock NOTIFICATION-TYPE
|
|
OBJECTS { wtnTrapCondition, wtnServiceAffected }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Spurious or intermittant loss of lock of internal
|
|
clocks in indoor unit."
|
|
::= { wtnTraps 6 }
|
|
|
|
wtnMcChannelFailCritical NOTIFICATION-TYPE
|
|
OBJECTS { wtnTrapCondition, wtnServiceAffected }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Radio overhead channel failure trap. May be caused by
|
|
signal path degradation, or equipment failure on local or
|
|
far end node."
|
|
::= { wtnTraps 7 }
|
|
|
|
wtnMcChannelFail NOTIFICATION-TYPE
|
|
OBJECTS { wtnTrapCondition, wtnServiceAffected }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Spurious or intermittant radio overhead channel failure trap.
|
|
May be caused by signal path degradation
|
|
or equipment failure on local or
|
|
far end node."
|
|
::= { wtnTraps 8 }
|
|
|
|
wtnOduEquipFailCritical NOTIFICATION-TYPE
|
|
OBJECTS { wtnTrapCondition, wtnServiceAffected }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Critical ODU hardware failure trap. Possible causes:
|
|
Synthesizer has lost desired frequency.
|
|
Could be loss of reference signal from IDU or hardware error.
|
|
Synthesizer hardware fault.
|
|
Possible component fault."
|
|
::= { wtnTraps 9 }
|
|
|
|
wtnOduEquipFail NOTIFICATION-TYPE
|
|
OBJECTS { wtnTrapCondition, wtnServiceAffected }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Spurious or intermittant ODU hardware failure trap.
|
|
Could be loss of reference signal from IDU or hardware error. "
|
|
::= { wtnTraps 10 }
|
|
|
|
wtnOduTempAlertCritical NOTIFICATION-TYPE
|
|
OBJECTS { wtnTrapCondition, wtnServiceAffected }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Significant deviation of ODU temperature from specified limits
|
|
May be power amp heating up or environment heat buildup, or
|
|
environment ice or frost."
|
|
::= { wtnTraps 11 }
|
|
|
|
wtnOduTempAlert NOTIFICATION-TYPE
|
|
OBJECTS { wtnTrapCondition, wtnServiceAffected }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Warning to indicate that ODU is approaching a significant
|
|
deviation of ODU temperature from specified limits.
|
|
May be power amp heating up or environment heat buildup, or
|
|
environment ice or frost."
|
|
::= { wtnTraps 12 }
|
|
|
|
wtnRSSIDeviation NOTIFICATION-TYPE
|
|
OBJECTS { wtnTrapCondition, wtnServiceAffected }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Receive signal strength at the odu is lower (in dB) than wtnOduRxRSSIThresh.
|
|
This alarm will persist until the RSSI rises above wtnOduRxRSSIThresh - wtnOduRxRssiHysteresisWindow.
|
|
|
|
May be from signal path degradation.
|
|
May be power amp heating up or environment heat buildup. "
|
|
::= { wtnTraps 13 }
|
|
|
|
wtnBerAlarm NOTIFICATION-TYPE
|
|
OBJECTS { wtnTrapCondition, wtnServiceAffected }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Modem reports temporary BER > threshold alarm.
|
|
Condition is true when current BER > wtnMdmRxBERThresh.
|
|
Condition will persist until current BER < ( wtnMdmRxBERThresh - wtnMdmRxBERHysteresisWindow ).
|
|
|
|
Probable fade burst.
|
|
Could be interference.
|
|
Could be incipient hardware fault"
|
|
::= { wtnTraps 14 }
|
|
|
|
wtnEbNoAlarm NOTIFICATION-TYPE
|
|
OBJECTS { wtnTrapCondition, wtnServiceAffected }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Modem reports temporary post-detection signal to noise ratio
|
|
below preset threshold wtnMdmRxEbNoThresh.
|
|
|
|
This condition will persist until the radio signal quality
|
|
rises above wtnMdmRxEbNoThresh - wtnMdmRxEbnoHysteresisWindow.
|
|
|
|
Probable fade or noise burst."
|
|
::= { wtnTraps 15 }
|
|
|
|
wtnTrapCondition OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
conditionPresent(1),
|
|
conditionCleared(2)
|
|
}
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Sent with wireless traps to indicate whether condition has
|
|
arrived or has gone away."
|
|
::= { wtnTrapData 1 }
|
|
|
|
wtnServiceAffected OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
serviceAffected(1),
|
|
serviceNotAffected(2)
|
|
}
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Flag sent with each trap to indicate whether service may be
|
|
affected by this particular trap condition.
|
|
|
|
Service affecting means that payload data (DS3, etc)
|
|
MAY be affected. Since a node does not have visibility
|
|
into the payloads this flag is determined by contingencies
|
|
such as signal quality measurements and introspective
|
|
hardware.
|
|
|
|
|
|
This flag should be ignored when the trap is sent to indicate the
|
|
trap condition has gone away."
|
|
::= { wtnTrapData 2 }
|
|
|
|
radioTotalTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF RadioTotalEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Table of current statistics in the style of rfc2493 current table."
|
|
::= { zhoneRadio 6 }
|
|
|
|
radioTotalEntry OBJECT-TYPE
|
|
SYNTAX RadioTotalEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Set of basic statistics for radio interface."
|
|
AUGMENTS { wtnConfigEntry }
|
|
::= { radioTotalTable 1 }
|
|
|
|
RadioTotalEntry ::=
|
|
SEQUENCE {
|
|
radioTotalES
|
|
Gauge32,
|
|
radioTotalSES
|
|
Gauge32,
|
|
radioTotalUAS
|
|
Gauge32
|
|
}
|
|
|
|
radioTotalES OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Number of seconds the radio link detected bit errors since
|
|
the system has been up, or since last reset.
|
|
|
|
If the BER is above the
|
|
user set threshhold then the readioCurrentSES count will be
|
|
incremented instead of this one. If the radio link is down
|
|
or a loss of signal is declared this count will not be
|
|
incremented.
|
|
|
|
Writing any value to this counter will reset the count."
|
|
::= { radioTotalEntry 1 }
|
|
|
|
radioTotalSES OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Count of the number of seconds the radio endured severe conditions
|
|
since system came up or value was reset.
|
|
|
|
A severe condition occurs if:
|
|
1 - received BER is greater exceeds the BER threshold and has not yet
|
|
dropped below the BER hysteresis window.
|
|
2- radio link failure. Radio signal cannot be detected.
|
|
|
|
Writing any value to this counter will reset the count."
|
|
::= { radioTotalEntry 2 }
|
|
|
|
radioTotalUAS OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Unavailable seconds. This value is incremented once per second after
|
|
ten consecutive radioCurrentSES (severe-error seconds) are counted.
|
|
An equipment failure will also increment this value.
|
|
|
|
Writing any value will cause the count to be reset."
|
|
::= { radioTotalEntry 3 }
|
|
|
|
|
|
END
|
|
|
|
--
|
|