Observium_CE/mibs/zhone/ZHONE-PHY-WTN-RADIO-MIB

1243 lines
50 KiB
Plaintext

--
-- phyWtnRadio.mib
-- MIB generated by MG-SOFT Visual MIB Builder Version 2.1 Build 205
-- Wednesday, August 22, 2001 at 02:16:01
--
ZHONE-PHY-WTN-RADIO-MIB DEFINITIONS ::= BEGIN
IMPORTS
InterfaceIndex
FROM IF-MIB
SnmpAdminString
FROM SNMP-FRAMEWORK-MIB
Integer32, Gauge32, OBJECT-TYPE, MODULE-IDENTITY, NOTIFICATION-TYPE
FROM SNMPv2-SMI
TruthValue, TimeStamp
FROM SNMPv2-TC
SkyZhoneScientificNotation, SkyZhoneRadioChannelNumber
FROM ZHONE-RADIO-TC-MIB
zhoneRadio, zhoneModules
FROM Zhone
ZhoneAdminString
FROM Zhone-TC;
--
--
zhonePhyWtnRadio MODULE-IDENTITY
LAST-UPDATED "190011031129Z"
ORGANIZATION
"Zhone Technologies, Inc."
CONTACT-INFO
" Postal:
Zhone Technologies, Inc.
@ Zhone Way
7001 Oakport Street
Oakland, CA 94621
USA
Toll-Free: +1 877-ZHONE20 (+1 877-946-6320)
Tel: +1-510-777-7000
Fax: +1-510-777-7001
E-mail: support@zhone.com
Zhone Technologies, Inc.
Wireless Group
120 Stony Point Rd
Suite 140
Santa Rosa, CA 95401
707 206 3600"
DESCRIPTION
"Module for radio provisioning and status."
REVISION "200107111300Z"
DESCRIPTION
"V01.04.01 - Use SkyZhoneScientificNotation rather
than SinglePrecision Floating point
format."
REVISION "200106071414Z"
DESCRIPTION
"V01.03.01 - add ODU loopback"
REVISION "200105181002Z"
DESCRIPTION
"V01.03.00 - Generalize for all SkyZhone products."
REVISION "200011240818Z"
DESCRIPTION
"V01.02.00 - Support traps."
REVISION "200011211535Z"
DESCRIPTION
"V01.00.01 - Add DDL markups."
REVISION "200011030944Z"
DESCRIPTION
"V01.00.00 - Initial Revision"
::= { zhoneModules 106 }
--
-- Node definitions
--
-- For use of radio interface regarding the ifTable,
-- see the zhoneRadio-TC.mib.
wtnConfigTable OBJECT-TYPE
SYNTAX SEQUENCE OF WtnConfigEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Radio, modem and ODU configuration information. An entry
is automatically created for each radio/modem/ODU
interface."
::= { zhoneRadio 1 }
wtnConfigEntry OBJECT-TYPE
SYNTAX WtnConfigEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Configuration entries"
INDEX { wtnRadioIfIndex }
::= { wtnConfigTable 1 }
WtnConfigEntry ::=
SEQUENCE {
wtnRadioIfIndex
InterfaceIndex,
wtnActiveChannelNumber
SkyZhoneRadioChannelNumber,
wtnActiveTransmitFrequency
SkyZhoneScientificNotation,
wtnStandbyChannelNumber
SkyZhoneRadioChannelNumber,
wtnStandbyTransmitFrequency
SkyZhoneScientificNotation,
wtnAutoChannelSwitchEnable
TruthValue,
wtnChannelSeparation
INTEGER,
wtnRadioAmplifiersEnable
TruthValue,
wtnRxBERThresh
SkyZhoneScientificNotation,
wtnRxBERHysteresisWindow
SkyZhoneScientificNotation,
wtnAntennaSize
INTEGER,
wtnIduOduCableLength
Integer32,
wtnRssiThresh
Integer32,
wtnRssiHysteresisWindow
Integer32,
wtnTrapsEnable
TruthValue,
wtnOduLoopback
INTEGER,
wtnOduIdentifier
SnmpAdminString,
wtnTxLevel
Integer32
}
wtnRadioIfIndex OBJECT-TYPE
SYNTAX InterfaceIndex
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This object should be made equal to the Ifindex used for
the radio interface."
::= { wtnConfigEntry 1 }
--
wtnActiveChannelNumber OBJECT-TYPE
SYNTAX SkyZhoneRadioChannelNumber
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Assigns one of N allowed frequency pairs for the radio
transmitter and reciever as described in zhoneRadio-TC.mib.
5.7Ghz family (sysObjId) systems:
---------------------------------
Writing to this value will change the current operating frequency.
The active channel is the default channel used on power up.
The channel is switched at the near end, and if possible, also at
the far end, towards minimizing link down time.
Every time the active channel number changes BITS WILL BE DROPPED.
In poor conditions there is a risk that the new frequency assignment
will fare more poorly. The user should expect alarms where the facility
is terminated until the nodes re-sync.
If a new active channel number is equal to the current value of
active channel, the command will have no effect and no error message will result.
Allowed range of allowed values: 0 - 17
This value will read back the current active channel.
Note: if this value is changed to a new active channel number,
and the system can not establish a radio link at this channel,
the system may automatically switch to the standby channel, if
wtnAutoChannelSwitchEnable is true(1), and the value of
wtnStandbyChannelNumber is neither the same channel number nor zero.
23Ghz family (sysObjId) systems:
-------------------------------
This variable is not used and so should not be presented to user.
Use direct frequency assignments instead.
See wtnActiveTransmitFrequency."
::= { wtnConfigEntry 2 }
wtnActiveTransmitFrequency OBJECT-TYPE
SYNTAX SkyZhoneScientificNotation
UNITS "Hz"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Current transmit frequency. As described in zhoneRadio-TC.mib.
23Ghz family: ( according to sysObjId )
-------------------------------------------
The transmit frequency is entered as a floating point number in Mhz,
for example, 23565.5 for 23.5655Ghz.
Note: receive frequency will also be affected by this parameter.
The resulting receive frequency will be simultaneously set to
this value +/- wtnChannelSeparation (plus or minus depending upon
whether the unit is an A or B type ODU.)
If the frequency entered or the calulated receive frequency
outside the range of the unit, an error will be returned and the
value left unchanged.
If a new active frequency is equal to the current value frequency,
the command will have no effect and no error message will result.
Every time the active frequency changes BITS WILL BE DROPPED.
In poor conditions there is a risk that the new frequency assignment
will fare more poorly. The user should expect alarms where the facility
is terminated until the nodes re-sync.
If the link is operational, the new frequencies will be changed
at the opposite end before the values at the local end are changed
in an attempt to minimize payload data loss.
5.7Ghz family of systems (according to sysObjId )
-------------------------------------------------
Value will reflect the frequency of the currently
active channel (wtnActiveChannelNumber).
Writing to this variable will have no effect."
::= { wtnConfigEntry 3 }
--
wtnStandbyChannelNumber OBJECT-TYPE
SYNTAX SkyZhoneRadioChannelNumber
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Assigns one of N allowed standby frequency pairs to the radio
transmitter and reciever as described in zhoneRadio-TC.mib.
5.7Ghz family (sysObjId) systems:
---------------------------------
Selection of one of N possible frequency pairs for the
standby radio transmitter reciever.
The Standby channel is the channel automatically switched to
in the event of failure of the current active channel, for example,
due to radio inteference. Automatic Switching must be enabled for
the standby channel to be switched to by setting wtnAutoChannelSwitchEnable
to true.
If the standby channel is assigned a value of zero (0), the automatic
switch to standby feature is effectively disabled, regardless of
the value of wtnAutoChannelSwitchEnable.
The channel is switched at the near end, and if possible, also at
the far end, towards minimizing link down time.
Allowed range of allowed values (see zhoneRadio-TC.mib ): 0 - 17
This value will read back the current standby channel.
Operation -
If a switch-to-standby channel event occurs, the active channel
number and the standby channel number swap values. For example,
before a radio failure: active channel = 1,
standby channel = 7, and
automatic channel switching is enabled.
After a radio failure on channel 1:
active channel = 7,
standby channel = 1, and
automatic channel switching is enabled.
If both channels fail to operate, the system will bounce back
and forth between the active and standby channels until the radio
link is re-established.
23Ghz family sysObjId systems:
-------------------------------
This variable is not used and so should not be presented to user.
Use direct frequency assignments instead.
See wtnStandbyTransmitFrequency.
"
::= { wtnConfigEntry 4 }
wtnStandbyTransmitFrequency OBJECT-TYPE
SYNTAX SkyZhoneScientificNotation
UNITS "Hz"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Standby Transmit frequency as described in zhoneRadio-TC.mib.
23Ghz family: ( according to sysObjId )
-------------------------------------------
If auto-switching is enabled, the
frequency shown will be used in the event the currently active
frequency fails due to low RSSI, or high BER. Note the switch
will occur only if wtnAutoChannelSwitchEnable is true(1).
The transmit frequency is entered as a floating point number in Mhz,
for example, 23565.5 for 23.5655Ghz.
If the frequency entered or the calulated receive frequency
outside the range of the unit, an error will be returned and the
value left unchanged.
If the link is operational, the new standby frequencies will be changed
at the opposite end before the values at the local end are changed.
5.7Ghz family: (according to sysObjId )
-----------------------------------------
Value will reflect the frequency of the currently
active channel (wtnStandbyChannelNumber).
Writing to this variable will have no effect."
::= { wtnConfigEntry 5 }
--
wtnAutoChannelSwitchEnable OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"true(1) - allows radio to automatically switch
to the standby channel in case of active channel
interference.
false(2) - inhibits radio from automatically
switching to the standby channel.
The default value is false(2)."
::= { wtnConfigEntry 6 }
wtnChannelSeparation OBJECT-TYPE
SYNTAX INTEGER
{
na(0),
s1232MHz(1),
s1200MHz(2),
s1008MHz(3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"23Ghz family (sysObjId) systems:
---------------------------------
Channel separation - the fixed difference between transmit
and receive frequency.
Only three values are allowed: s1232MHz(1), s1200MHz,
and s1008MHz.
This value is used to automatically calculate the receive
frequency, when the transmit frequency is entered.
Default value: s1232Mhz(1)
5.7Ghz family (sysObjId) systems:
---------------------------------
Not used. ( Internally fixed at 475MHz fixed ).
Default value: na(0)"
::= { wtnConfigEntry 7 }
--
wtnRadioAmplifiersEnable OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"true(1) - Enables amplifiers for transmitter and receiver.
The radio will begin transmitting and receiving data. If the ODU
is looped back, unable to lock onto a signal, or the ODU equipment
has failed, the enable command will return an error trap and
the amplifier enable state will transition to disableAmplifiers(2).
false(2) - shuts down the transmit and receive amplifiers of the ODU.
This will cause the link to go down. Payload will be dropped.
When the amplifiers are turned off, the active and standby
channel assignments may be freely changed, if necessary,
but notification of such changes to the far end will not be done
automatically. That is, channel assignments made when the
amplifiers are disabled must be done manually at each node -
near end and far end.
Default value after power up is false(2).
"
::= { wtnConfigEntry 8 }
--
wtnRxBERThresh OBJECT-TYPE
SYNTAX SkyZhoneScientificNotation
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Set point of BER alarm. When the modem BER estimate
is higher than this value, a modem BER alarm will occur.
The BER over threshold Causes trap wtnBerAlarm to be emitted.
The alarm will stay present until the modem BER estimate
is lower than this set point less the hysteresis window
wtnMdmRxBERHysteresisWindow.
A value of 0 disables the BER threshold alarm.
Allowed range is 1.0e-1 to 1.0e-12.
BER is assumed accumulated over a second."
::= { wtnConfigEntry 9 }
--
wtnRxBERHysteresisWindow OBJECT-TYPE
SYNTAX SkyZhoneScientificNotation
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"After a wtnBerAlarm trap is sent, it is revoked using the same trap with
the condition flag set to false when the modem BER estimate is lower
than the set point wtnModemRxBERThresh less this value.
Valid values are 0, and the range from 1.0e-1 to 1.0e-12.
A value of 0 indicates no hysteresis.
BER is assumed accumulated over the last second."
::= { wtnConfigEntry 10 }
--
wtnAntennaSize OBJECT-TYPE
SYNTAX INTEGER
{
oneFoot(1),
twoFeet(2),
fourFeet(4),
sixFeet(6)
}
UNITS "feet"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Initial power of transmitter is based upon antenna diameter.
oneFoot(1) - a one foot dish
twoFeet(2) - a two foot dish
fourFeet(4) - a four foot dish
sixFeet(6) - a six foot dish
FCC mandates a maximimum EIRP (Effective Isotropic
Radiated Power) level, which is directly dependent
upon antenna size.
The system will use antenna size to determine a
power level in accordance to maxmimum EIRP.
5.7Ghz family
-------------------
The equipment is shipped with a dish that
is one of 3 sizes:
twoFeet(2) - a two foot dish
fourFeet(4) - a four foot dish
sixFeet(6) - a six foot dish
Default value sixFeet(3).
23Ghz family
-------------------
The equipment is shipped with a dish that
is one of 2 sizes:
oneFoot(1) - a one foot dish
twoFeet(2) - a two foot dish
Default value: twoFeet(2).
"
DEFVAL { sixFeet }
::= { wtnConfigEntry 11 }
--
wtnIduOduCableLength OBJECT-TYPE
SYNTAX Integer32 (0..300)
UNITS "feet"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The length of the coaxial cable between the Indoor
Unit and the Outdoor Unit.
Used internally to compensate for the coaxial cable's
natural attenuation of the signal.
This cable is cut to its appropriate length when the system
is installed.
Default value: 0 feet."
DEFVAL { 0 }
::= { wtnConfigEntry 12 }
wtnRssiThresh OBJECT-TYPE
SYNTAX Integer32 (-99..-30)
UNITS "dB"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Set point of RSSI thresholdalarm. When the ODU RSSI estimate
is lower than this value, a wtnRssiDeviation trap will be emitted.
When the ODU RSSI estimate is higher than this set point
plus the hysteresis window wtnOduRxRSSIHysteresisWindow, the same
trap will be re-emitted with condition = false..
Receive signal strength (RSSI) reported by near end
ODU.
Typical values range from -95dB to -30dB.
Tyipcal nominal value is -60dB."
DEFVAL { -80 }
::= { wtnConfigEntry 13 }
--
wtnRssiHysteresisWindow OBJECT-TYPE
SYNTAX Integer32
UNITS "dB"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"After a wtnRssiDeviation Trap is sent, an the trap is re-emitted
with the condition flag set to false when the ODU RSSI
estimate is higher than the set point wtnOduRxRSSIThresh plus this value.
Typical value of window size is 10dB."
DEFVAL { 10 }
::= { wtnConfigEntry 14 }
--
wtnTrapsEnable OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"When true(1), radio traps may be emitted.
When false(2), radio traps will be absorbed.
Default value is true(1) = enabled."
::= { wtnConfigEntry 15 }
wtnOduLoopback OBJECT-TYPE
SYNTAX INTEGER
{
loopbackOn(1),
loopbackOff(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"loopbackOn(1) - engages the loopback function at the ODU (outdoor unit).
Data normally transmitted by the radio is instead returned to the IDU
(indoor unit). This is useful to check the integrity of the IDU, the
integrity of the cable connecting IDU to ODU, and of some portions
of ODU circuitry.
ifAdminStatus must be in 'testing' mode for loopbackOn to be accepted.
Once the loopback is turned on verify that there is no radio alarm
condition. Also, any line data received on the line interface
(DS3, STM-1, E1, etc) will be looped back and transmitted to it.
loopbackOff(2) - disengages the loopback function at the ODU.
Causes the radio to re-acquire the signal from the far end, if any."
::= { wtnConfigEntry 16 }
--
wtnOduIdentifier OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Textual description of ODU.
This string typically identifies the location of antenna."
::= { wtnConfigEntry 17 }
--
wtnTxLevel OBJECT-TYPE
SYNTAX Integer32 (0..45)
UNITS "dB"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Desired transmitter signal strength (TSSI) at antenna.
Note: Accuracy decreases as power levels decrease below 20dBm.
FCC maximum power allowed is +30dBm. "
DEFVAL { 0 }
::= { wtnConfigEntry 18 }
wtnStatusTable OBJECT-TYPE
SYNTAX SEQUENCE OF WtnStatusEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Contains the status of the Radio, ODU and Modem."
::= { zhoneRadio 2 }
wtnStatusEntry OBJECT-TYPE
SYNTAX WtnStatusEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Entries for radio, ODU and modem status."
AUGMENTS { wtnConfigEntry }
::= { wtnStatusTable 1 }
WtnStatusEntry ::=
SEQUENCE {
wtnCriticalAlarmStatus
BITS,
wtnCriticalAlarmStatusLastChange
TimeStamp,
wtnMinorAlarmStatus
BITS,
wtnMinorAlarmStatusLastChange
TimeStamp,
wtnOduTemperature
Integer32,
wtnReceiveFrequency
SkyZhoneScientificNotation
}
--
wtnCriticalAlarmStatus OBJECT-TYPE
SYNTAX BITS
{
rssiDeviation(0),
iduOOL(1),
oduTempAlert(2),
rxBerAlarm(3),
rxEbnoAlarm(4),
unused5(5),
unused6(6),
unused7(7),
iduEquipFail(8),
oduEquipFail(9),
iduOduLinkFail(10),
mcChannelFail(11),
unused12(12),
unused13(13),
unused14(14),
serviceAffected(15)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Current radio alarm status details.
BIT Hex Decimal BIT NAME
Number Value Value
------ ------ ------- ----------------------
0 0x01 1 RSSI_DEVIATION
1 0x02 2 IDU_OOL
2 0x04 4 ODU_TEMP_ALERT
3 0x08 8 RX_BER_ALARM
4 0x10 16 RX_EBNO_ALARM
5 0x20 32 (reserved)
6 0x40 64 (reserved)
7 0x80 128 (reserved)
8 0x100 256 IDU_EQUIP_FAIL
9 0x200 512 ODU_EQUIP_FAIL
10 0x400 1024 IDU_ODU_LINK_FAIL
11 0x800 2048 MC_CHANNEL_FAIL
12 0x1000 4096 (reserved)
13 0x2000 8192 (reserved)
14 0x4000 16384 (reserved)
15 0x8000 32768 SERVICE_AFFECTED
IDU_EQUIP_FAIL - can be caused by:
power supply failure, watchdog timeout, or other internal
failure on indoor unit.
IDU_ODU_LINK_FAIL - can be caused by:
IDU/ODU cable failure, bad connection, or equipment failure
IDU_OOL - can be caused by:
intermittent loss of lock of internal clocks
MC_CHANNEL_FAIL - can be caused by:
Signal path (air) degradation, or internal equipment failure
on near end or far end node.
ODU_EQUIP_FAIL - can be caused by:
Loss of frequency lock, loss of clock reference, power fault,
excessive transmitter power, signal path degradation,
frequency drift, or internal failure of equipment in outdoor
unit.
ODU_TEMP_ALERT - can be caused by:
Operating temperature too high or too low. Allowable range
of operating temperatures ( in ODU ) are -40C to +65C.
RSSI_DEVIATION - can be caused by:
signal path (air) degradation, excessive heat buildup at ODU,
or frequency drift.
RX_BER_ALARM - can be caused by:
RF noise burst, fade burst, interference, or internal equipment
failure.
RX_EBNO_ALARM - can be caused by:
Fade, noise burst, or internal equipment stress.
SERVICE_AFFECTED - indicates a predicted loss of data
or quality of service in transport due to any of the
above conditions."
::= { wtnStatusEntry 1 }
wtnCriticalAlarmStatusLastChange OBJECT-TYPE
SYNTAX TimeStamp
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Time Stamp of last change of critical alarm status
wtnRadioCriticalAlmStatus. "
::= { wtnStatusEntry 2 }
wtnMinorAlarmStatus OBJECT-TYPE
SYNTAX BITS
{
rssiDeviation(0),
iduOOL(1),
oduTempAlert(2),
rxBerAlarm(3),
rxEbnoAlarm(4),
unused5(5),
unused6(6),
unused7(7),
iduEquipFail(8),
oduEquipFail(9),
iduOduLinkFail(10),
mcChannelFail(11),
unused12(12),
unused13(13),
unused14(14),
serviceAffected(15)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Current radio alarm status details.
BIT Hex Decimal BIT NAME
Number Value Value
------ ------ ------- ----------------------
0 0x01 1 RSSI_DEVIATION
1 0x02 2 IDU_OOL
2 0x04 4 ODU_TEMP_ALERT
3 0x08 8 RX_BER_ALARM
4 0x10 16 RX_EBNO_ALARM
5 0x20 32 (reserved)
6 0x40 64 (reserved)
7 0x80 128 (reserved)
8 0x100 256 IDU_EQUIP_FAIL
9 0x200 512 ODU_EQUIP_FAIL
10 0x400 1024 IDU_ODU_LINK_FAIL
11 0x800 2048 MC_CHANNEL_FAIL
12 0x1000 4096 (reserved)
13 0x2000 8192 (reserved)
14 0x4000 16384 (reserved)
15 0x8000 32768 SERVICE_AFFECTED
IDU_EQUIP_FAIL - can be caused by:
power supply failure, watchdog timeout, or other internal
failure on indoor unit.
IDU_ODU_LINK_FAIL - can be caused by:
IDU/ODU cable failure, bad connection, or equipment failure
IDU_OOL - can be caused by:
intermittent loss of lock of internal clocks
MC_CHANNEL_FAIL - can be caused by:
Signal path (air) degradation, or internal equipment failure
on near end or far end node.
ODU_EQUIP_FAIL - can be caused by:
Loss of frequency lock, loss of clock reference, power fault,
excessive transmitter power, signal path degradation,
frequency drift, or internal failure of equipment in outdoor
unit.
ODU_TEMP_ALERT - can be caused by:
Operating temperature too high or too low. Allowable range
of operating temperatures ( in ODU ) are -40C to +65C.
RSSI_DEVIATION - can be caused by:
signal path (air) degradation, excessive heat buildup at ODU,
or frequency drift.
RX_BER_ALARM - can be caused by:
RF noise burst, fade burst, interference, or internal equipment
failure.
RX_EBNO_ALARM - can be caused by:
Fade, noise burst, or internal equipment stress.
The SERVICE_AFFECTING bit should always = 0 on this variable
because, by definition, minor alarms may not affect service.
"
::= { wtnStatusEntry 3 }
wtnMinorAlarmStatusLastChange OBJECT-TYPE
SYNTAX TimeStamp
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Time Stamp of last change of minor alarm status
wtnRadioMinorAlmStatus."
::= { wtnStatusEntry 4 }
--
wtnOduTemperature OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Current temperature measured at local outdoor unit, in
degrees Celsius (Centigrade)."
::= { wtnStatusEntry 5 }
wtnReceiveFrequency OBJECT-TYPE
SYNTAX SkyZhoneScientificNotation
UNITS "Hz"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Current frequency at which radio receiver is set."
::= { wtnStatusEntry 6 }
wtnInfoTable OBJECT-TYPE
SYNTAX SEQUENCE OF WtnInfoEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Table augments the wtnConfigTable"
::= { zhoneRadio 3 }
wtnInfoEntry OBJECT-TYPE
SYNTAX WtnInfoEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Device information entries for the radio, modem and ODU."
AUGMENTS { wtnConfigEntry }
::= { wtnInfoTable 1 }
WtnInfoEntry ::=
SEQUENCE {
wtnOduSerialNumber
ZhoneAdminString,
wtnOduMfgCLEICode
ZhoneAdminString
}
--
wtnOduSerialNumber OBJECT-TYPE
SYNTAX ZhoneAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Manufacturing Serial Number for Outdoor Unit.
Format of the serial number is XXXXX, where X = 0 to F."
::= { wtnInfoEntry 1 }
--
wtnOduMfgCLEICode OBJECT-TYPE
SYNTAX ZhoneAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"CLEI code for Outdoor Unit."
::= { wtnInfoEntry 2 }
wtnSnapshotTable OBJECT-TYPE
SYNTAX SEQUENCE OF WtnSnapshotEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Table to collect statistics at radio demodulator of
wireless transport node."
::= { zhoneRadio 4 }
wtnSnapshotEntry OBJECT-TYPE
SYNTAX WtnSnapshotEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Entry into wireless transport local radio status table.
No rows may be added to this table."
AUGMENTS { wtnConfigEntry }
::= { wtnSnapshotTable 1 }
WtnSnapshotEntry ::=
SEQUENCE {
wtnRSSI
Integer32,
wtnTSSI
Integer32,
wtnRxBerFloat
SkyZhoneScientificNotation,
wtnRcvEbNoFloat
SkyZhoneScientificNotation
}
--
wtnRSSI OBJECT-TYPE
SYNTAX Integer32 (-90..0)
UNITS "dBm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Current Received Signal Strength in dB as registered at
the near end Outdoor Unit. This number is updated about once per
second.
Typical values range from -95dB to -30dB.
Tyipcal nominal value is -60dB."
::= { wtnSnapshotEntry 1 }
wtnTSSI OBJECT-TYPE
SYNTAX Integer32 (0..45)
UNITS "dBm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Estimated transmitter signal strength (TSSI) at antenna.
Note: maximum level allowed by FCC is 30dBm."
::= { wtnSnapshotEntry 2 }
--
wtnRxBerFloat OBJECT-TYPE
SYNTAX SkyZhoneScientificNotation
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Current received BER at local Indoor Unit demodulator over
the previous 250ms."
::= { wtnSnapshotEntry 3 }
--
wtnRcvEbNoFloat OBJECT-TYPE
SYNTAX SkyZhoneScientificNotation
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Current local demodulator (rcvd) Energy-bit per noise.
Conveys energy in each bit as compared to energy in noise."
::= { wtnSnapshotEntry 4 }
wtnTrapData OBJECT IDENTIFIER ::= { zhoneRadio 5 }
wtnTraps OBJECT IDENTIFIER ::= { wtnTrapData 0 }
wtnIduEquipFailCritical NOTIFICATION-TYPE
OBJECTS { wtnTrapCondition, wtnServiceAffected }
STATUS current
DESCRIPTION
"Critical indoor equipment failure trap.
Can be caused by:
power supply failure, watchdog timeout, or other internal
failure on indoor unit."
::= { wtnTraps 1 }
wtnIduEquipFail NOTIFICATION-TYPE
OBJECTS { wtnTrapCondition, wtnServiceAffected }
STATUS current
DESCRIPTION
"Non-critical indoor equipment failure trap.
Can be caused by:
spurious power supply failure,
or other temporary internal failure on indoor unit."
::= { wtnTraps 2 }
wtnIduOduLinkFailCritical NOTIFICATION-TYPE
OBJECTS { wtnTrapCondition, wtnServiceAffected }
STATUS current
DESCRIPTION
"Critical failure of IDU to ODU communications link trap.
can be caused by:
IDU/ODU cable failure,
bad connection, or
equipment failure."
::= { wtnTraps 3 }
wtnIduOduLinkFail NOTIFICATION-TYPE
OBJECTS { wtnTrapCondition, wtnServiceAffected }
STATUS current
DESCRIPTION
"Intermittent failure of IDU to ODU communications link trap.
can be caused by:
IDU/ODU cable failure,
bad connection,
or spurious equipment failure."
::= { wtnTraps 4 }
wtnIduOutOfLockCritical NOTIFICATION-TYPE
OBJECTS { wtnTrapCondition, wtnServiceAffected }
STATUS current
DESCRIPTION
"Permanent or persistant loss of lock of internal clocks
in indoor unit."
::= { wtnTraps 5 }
wtnIduOutOfLock NOTIFICATION-TYPE
OBJECTS { wtnTrapCondition, wtnServiceAffected }
STATUS current
DESCRIPTION
"Spurious or intermittant loss of lock of internal
clocks in indoor unit."
::= { wtnTraps 6 }
wtnMcChannelFailCritical NOTIFICATION-TYPE
OBJECTS { wtnTrapCondition, wtnServiceAffected }
STATUS current
DESCRIPTION
"Radio overhead channel failure trap. May be caused by
signal path degradation, or equipment failure on local or
far end node."
::= { wtnTraps 7 }
wtnMcChannelFail NOTIFICATION-TYPE
OBJECTS { wtnTrapCondition, wtnServiceAffected }
STATUS current
DESCRIPTION
"Spurious or intermittant radio overhead channel failure trap.
May be caused by signal path degradation
or equipment failure on local or
far end node."
::= { wtnTraps 8 }
wtnOduEquipFailCritical NOTIFICATION-TYPE
OBJECTS { wtnTrapCondition, wtnServiceAffected }
STATUS current
DESCRIPTION
"Critical ODU hardware failure trap. Possible causes:
Synthesizer has lost desired frequency.
Could be loss of reference signal from IDU or hardware error.
Synthesizer hardware fault.
Possible component fault."
::= { wtnTraps 9 }
wtnOduEquipFail NOTIFICATION-TYPE
OBJECTS { wtnTrapCondition, wtnServiceAffected }
STATUS current
DESCRIPTION
"Spurious or intermittant ODU hardware failure trap.
Could be loss of reference signal from IDU or hardware error. "
::= { wtnTraps 10 }
wtnOduTempAlertCritical NOTIFICATION-TYPE
OBJECTS { wtnTrapCondition, wtnServiceAffected }
STATUS current
DESCRIPTION
"Significant deviation of ODU temperature from specified limits
May be power amp heating up or environment heat buildup, or
environment ice or frost."
::= { wtnTraps 11 }
wtnOduTempAlert NOTIFICATION-TYPE
OBJECTS { wtnTrapCondition, wtnServiceAffected }
STATUS current
DESCRIPTION
"Warning to indicate that ODU is approaching a significant
deviation of ODU temperature from specified limits.
May be power amp heating up or environment heat buildup, or
environment ice or frost."
::= { wtnTraps 12 }
wtnRSSIDeviation NOTIFICATION-TYPE
OBJECTS { wtnTrapCondition, wtnServiceAffected }
STATUS current
DESCRIPTION
"Receive signal strength at the odu is lower (in dB) than wtnOduRxRSSIThresh.
This alarm will persist until the RSSI rises above wtnOduRxRSSIThresh - wtnOduRxRssiHysteresisWindow.
May be from signal path degradation.
May be power amp heating up or environment heat buildup. "
::= { wtnTraps 13 }
wtnBerAlarm NOTIFICATION-TYPE
OBJECTS { wtnTrapCondition, wtnServiceAffected }
STATUS current
DESCRIPTION
"Modem reports temporary BER > threshold alarm.
Condition is true when current BER > wtnMdmRxBERThresh.
Condition will persist until current BER < ( wtnMdmRxBERThresh - wtnMdmRxBERHysteresisWindow ).
Probable fade burst.
Could be interference.
Could be incipient hardware fault"
::= { wtnTraps 14 }
wtnEbNoAlarm NOTIFICATION-TYPE
OBJECTS { wtnTrapCondition, wtnServiceAffected }
STATUS current
DESCRIPTION
"Modem reports temporary post-detection signal to noise ratio
below preset threshold wtnMdmRxEbNoThresh.
This condition will persist until the radio signal quality
rises above wtnMdmRxEbNoThresh - wtnMdmRxEbnoHysteresisWindow.
Probable fade or noise burst."
::= { wtnTraps 15 }
wtnTrapCondition OBJECT-TYPE
SYNTAX INTEGER
{
conditionPresent(1),
conditionCleared(2)
}
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"Sent with wireless traps to indicate whether condition has
arrived or has gone away."
::= { wtnTrapData 1 }
wtnServiceAffected OBJECT-TYPE
SYNTAX INTEGER
{
serviceAffected(1),
serviceNotAffected(2)
}
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"Flag sent with each trap to indicate whether service may be
affected by this particular trap condition.
Service affecting means that payload data (DS3, etc)
MAY be affected. Since a node does not have visibility
into the payloads this flag is determined by contingencies
such as signal quality measurements and introspective
hardware.
This flag should be ignored when the trap is sent to indicate the
trap condition has gone away."
::= { wtnTrapData 2 }
radioTotalTable OBJECT-TYPE
SYNTAX SEQUENCE OF RadioTotalEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Table of current statistics in the style of rfc2493 current table."
::= { zhoneRadio 6 }
radioTotalEntry OBJECT-TYPE
SYNTAX RadioTotalEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Set of basic statistics for radio interface."
AUGMENTS { wtnConfigEntry }
::= { radioTotalTable 1 }
RadioTotalEntry ::=
SEQUENCE {
radioTotalES
Gauge32,
radioTotalSES
Gauge32,
radioTotalUAS
Gauge32
}
radioTotalES OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Number of seconds the radio link detected bit errors since
the system has been up, or since last reset.
If the BER is above the
user set threshhold then the readioCurrentSES count will be
incremented instead of this one. If the radio link is down
or a loss of signal is declared this count will not be
incremented.
Writing any value to this counter will reset the count."
::= { radioTotalEntry 1 }
radioTotalSES OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Count of the number of seconds the radio endured severe conditions
since system came up or value was reset.
A severe condition occurs if:
1 - received BER is greater exceeds the BER threshold and has not yet
dropped below the BER hysteresis window.
2- radio link failure. Radio signal cannot be detected.
Writing any value to this counter will reset the count."
::= { radioTotalEntry 2 }
radioTotalUAS OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Unavailable seconds. This value is incremented once per second after
ten consecutive radioCurrentSES (severe-error seconds) are counted.
An equipment failure will also increment this value.
Writing any value will cause the count to be reset."
::= { radioTotalEntry 3 }
END
--