Observium_CE/mibs/zhone/ZHONE-CARD-DIAGNOSTICS-MIB

958 lines
28 KiB
Plaintext

--
-- genCardDiagnostics.mib
-- MIB generated by MG-SOFT Visual MIB Builder Version 3.0 Build 285
-- Friday, March 05, 2010 at 14:11:29
--
ZHONE-CARD-DIAGNOSTICS-MIB DEFINITIONS ::= BEGIN
IMPORTS
InterfaceIndexOrZero
FROM IF-MIB
OBJECT-GROUP
FROM SNMPv2-CONF
TimeTicks, Integer32, Counter32, OBJECT-TYPE, MODULE-IDENTITY,
OBJECT-IDENTITY, NOTIFICATION-TYPE
FROM SNMPv2-SMI
DateAndTime
FROM SNMPv2-TC
zhoneCard, zhoneShelfIndex, zhoneSlotIndex, zhoneModules, zhoneShelfIndex,
zhoneSlotIndex
FROM Zhone
ZhoneDiagAction, ZhoneDiagResult, ZhoneRowStatus
FROM Zhone-TC;
-- The Zhone CardDiagnostics MIB defines management variables for testing
-- cards on Zhone systems.
--
-- /vob/zhonetools/bin/pahrser.pl rfc2514.mib rfc1907.mib iftype.mib
-- rfc2233.mib rfc2571.mib Zhone.mib Zhone-TC.mib genCardDiagnostics.mib
--
-- /vob/EPILOGUE/binaries/emissary/solaris/mibcomp rfc2514.mib rfc1907.mib
-- iftype.mib rfc2233.mib rfc2571.mib Zhone.mib Zhone-TC.mib -stub
-- -o mtacHdlrs.c genCardDiagnostics.mib
--
-- 1. Card diagnostics request information
--
--
--
-- 2. Card diagnostics result information.
--
--
--
--
-- 1.3.6.1.4.1.5504.6.11
zhoneCardDiagnosticsModule MODULE-IDENTITY
LAST-UPDATED "201003030930Z" -- March 03, 2010 at 09:30 GMT
ORGANIZATION
"Zhone Technologies, Inc."
CONTACT-INFO
" Postal:
Zhone Technologies, Inc.
@ Zhone Way
7001 Oakport Street
Oakland, CA 94621
USA
Toll-Free: +1 877-ZHONE20 (+1 877-946-6320)
Tel: +1-510-777-7000
Fax: +1-510-777-7001
E-mail: support@zhone.com"
DESCRIPTION
"Contains the diagnostics and results available on a per card or resource basis."
REVISION "201003051405Z" -- March 05, 2010 at 14:05 GMT
DESCRIPTION
"V01.00.14 change tactestresults to persistent"
REVISION "200905140939Z" -- May 14, 2009 at 09:39 GMT
DESCRIPTION
"V01.00.13 add optional parameters for line test"
REVISION "200905072237Z" -- May 07, 2009 at 22:37 GMT
DESCRIPTION
"V01.00.12 mtac name changes"
REVISION "200901121536Z" -- January 12, 2009 at 15:36 GMT
DESCRIPTION
"add trap for mtac ringer power bus fault alarm"
REVISION "200810220528Z" -- October 22, 2008 at 05:28 GMT
DESCRIPTION
"Changing the mtac name into tac and removing the name metallic."
REVISION "200607241128Z" -- July 24, 2006 at 11:28 GMT
DESCRIPTION
"V01.00.09 - Add new Mtac test controls
for the Legerity Test Suite."
REVISION "200111141528Z" -- November 14, 2001 at 15:28 GMT
DESCRIPTION
"V01.00.08. Added comments for mtactestmode"
REVISION "200108301121Z" -- August 30, 2001 at 11:21 GMT
DESCRIPTION
"V01.00.07 - Modify description of zhoneCardDiagType to include
specific diagnostics for T3TDM card"
REVISION "200108271814Z" -- August 27, 2001 at 18:14 GMT
DESCRIPTION
"V01.00.06 - Modify description of zhoneCardDiagType to include
specific diagnostics for VASP card
- Add DEFVAL for zhoneCardDiagType
- Modify DEFVAL for zhoneCardDiagRepetition, zhoneCardDiagDuration"
REVISION "200106281201Z" -- June 28, 2001 at 12:01 GMT
DESCRIPTION
"V01.00.05 - fix the 17 slot problem"
REVISION "200106261240Z" -- June 26, 2001 at 12:40 GMT
DESCRIPTION
"V01.00.04 - Added zhoneMetallicTest Table entry,and also added the markups. Removed zhoneCardDiagIndex field from zhoneCardDiagObjects. "
REVISION "200012121630Z" -- December 12, 2000 at 16:30 GMT
DESCRIPTION
"V01.00.03 - move zhoneCardDiagNextIndex into table."
REVISION "200010191945Z" -- October 19, 2000 at 19:45 GMT
DESCRIPTION
"V01.00.02 - Corrected revision information."
REVISION "200010171032Z" -- October 17, 2000 at 10:32 GMT
DESCRIPTION
"VO1.00.01 - Added ZHONE_KEYWORD markup."
REVISION "200009121107Z" -- September 12, 2000 at 11:07 GMT
DESCRIPTION
"V01.00.00 - Initial Release"
::= { zhoneModules 11 }
--
-- Node definitions
--
-- 1.3.6.1.4.1.5504.3.3.5
zhoneCardDiagNextTable OBJECT-TYPE
SYNTAX SEQUENCE OF ZhoneCardDiagNextEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Augment table of the unit/card resource but specific
to the diagnostic results information. This card
contains the index to create diagnostics table
entries (zhoneCardDiagEntry) which contains all the data
for executing and obtaining diagnostic results."
::= { zhoneCard 5 }
-- 1.3.6.1.4.1.5504.3.3.5.1
zhoneCardDiagNextEntry OBJECT-TYPE
SYNTAX ZhoneCardDiagNextEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This is the card diagnostics next index table which contains
all the data for:
- index for creating next zhoneCardDiagEntry."
INDEX { zhoneShelfIndex, zhoneSlotIndex }
::= { zhoneCardDiagNextTable 1 }
ZhoneCardDiagNextEntry ::=
SEQUENCE {
zhoneCardDiagNextIndex
Integer32
}
--
--
-- 1.3.6.1.4.1.5504.3.3.5.1.1
zhoneCardDiagNextIndex OBJECT-TYPE
SYNTAX Integer32 (1..10)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"We allow ten diagnostic requests from multiple
interfaces.
The diagNextIndex represents the next available
diagnostic request handle for requesting a
diagnostic.
NOTE: this operates as a wrap-around counter starting
at 1 and wrapping around to 1 after reaching 10."
::= { zhoneCardDiagNextEntry 1 }
-- 1.3.6.1.4.1.5504.3.3.6
zhoneCardDiagTable OBJECT-TYPE
SYNTAX SEQUENCE OF ZhoneCardDiagEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Augment table of the unit/card resource but specific
to the diagnostic results information. This is the card
diagnostics table which contains all the data for
executing and obtaining diagnostic results."
::= { zhoneCard 6 }
-- 1.3.6.1.4.1.5504.3.3.6.1
zhoneCardDiagEntry OBJECT-TYPE
SYNTAX ZhoneCardDiagEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This is the card diagnostics table which contains all the data for:
- invoking diagnostics,
- obtaining diagnostic results."
INDEX { zhoneShelfIndex, zhoneSlotIndex, zhoneCardDiagIndex }
::= { zhoneCardDiagTable 1 }
ZhoneCardDiagEntry ::=
SEQUENCE {
zhoneCardDiagIndex
Integer32,
zhoneCardDiagType
INTEGER,
zhoneCardDiagAction
ZhoneDiagAction,
zhoneCardDiagRepetition
Integer32,
zhoneCardDiagDuration
Integer32,
zhoneCardDiagResult
ZhoneDiagResult,
zhoneCardDiagPassCount
Counter32,
zhoneCardDiagFailCount
Counter32,
zhoneCardDiagDetails
OCTET STRING,
zhoneCardDiagStartTime
DateAndTime,
zhoneCardDiagEndTime
DateAndTime,
zhoneCardDiagRowStatus
ZhoneRowStatus
}
--
--
-- 1.3.6.1.4.1.5504.3.3.6.1.1
zhoneCardDiagIndex OBJECT-TYPE
SYNTAX Integer32 (1..10)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"We allow ten diagnostic requests from multiple
interfaces.
The diagIndex represents the diagnostic request to
start a diagnostic or obtain test results for a
completed diagnostic.
NOTE: this operates as a wrap-around counter starting
at 1 and wrapping around to 1 after reaching 10."
::= { zhoneCardDiagEntry 1 }
--
--
-- 1.3.6.1.4.1.5504.3.3.6.1.2
zhoneCardDiagType OBJECT-TYPE
SYNTAX INTEGER
{
selftest(1),
supvBus(2),
cardEEprom(3),
frbus(4),
pcmcia(5),
shelfLamp(6),
realTimeClock(7),
fanTray(8),
shelfMonitor(9),
ioCard(10),
mezzanineCard(11),
backPlane(12),
midPlane(13)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This field specifies the diagnostic to execute. The default
value is 'selftest'.
NOTE: not all of the individual diagnostics are available on
every Zhone card type.
NOTE: Zhone card types (cardZhoneType) are defined in the
genCardResources.mib
List of possible diagnostics:
============================
Common to all PLS cards
-----------------------
selftest(1)
- this diagnostic will execute all of the individual tests
available on this card.
Supports: diagStart, diagStop, diagRepetition.
cardEEprom(3)
- this diagnostic will verify the main card EEPROM checksum.
Supports: diagStart, diagStop, diagRepetition.
frbus(4)
- this diagnostic will verify that the BAN slot card can
access the Fhrame Bus by doing a loopback with 10 message
of 100 bytes.
Supports: diagStart, diagStop, diagRepetition.
backPlane(12)
- this diagnostic will verify that the BAN slot card can
access the back plane by verifying the back plane EEPROM
checksum.
Supports: diagStart, diagStop, diagRepetition.
cardZhoneType::infoServices(3) specific
---------------------------------------
supvBus(2)
- this diagnostic will verify that the BAN slot card can
access the supervisory Bus by doing a loopback of 20
bytes.
Supports: diagStart, diagStop, diagRepetition.
pcmcia(5)
- this diagnostic will verify that the InfoServ card can
access the PCMCIA flash card I/O by doing a file create,
write, and read of length 4000 bytes.
Supports: diagStart, diagStop, diagRepetition.
shelfLamp(6)
- this diagnostic will illuminate the shelf alarm indicators
for a period of 1.5 seconds. The indicators will return to
their original settings after the diagnostic completes.
Supports: diagStart, diagStop, diagRepetition.
realTimeClk(7)
- this diagnostic will verify that the real time clock
increments.
Supports: diagStart, diagStop, diagRepetition.
fanTray(8)
- this diagnostic tests that the fan tray is operational by
verifying the fan tray EEPROM checksum.
Supports: diagStart, diagStop, diagRepetition.
shelfMonitor(9)
- this diagnostic tests the shelf monitor board is operational
by checking the POST status register and verifying the shelf
monitor board EEPROM checksum.
Supports: diagStart, diagStop, diagRepetition.
midPlane(13)
- this diagnostic will verify that the mid plane card is present
by verifying the mid plane card EEPROM checksum.
Supports: diagStart, diagStop, diagRepetition.
cardZhoneType::vasp(5) specific
---------------------------------
ioCard(10)
- this diagnostic will verify that the I/O card is present by
verifying the I/O card EEPROM checksum.
Supports: diagStart, diagStop, diagRepetition.
mezzanineCard(11)
- this diagnostic will test that the mezzanine card is operational
by verifying the mezzanine card EEPROM checksum.
Supports: diagStart, diagStop, diagRepetition.
cardZhoneType::t3Tdm(6) specific
---------------------------------
ioCard(10)
- this diagnostic will verify that the I/O card is present by
verifying the I/O card EEPROM checksum.
Supports: diagStart, diagStop, diagRepetition.
midPlane(13)
- this diagnostic will verify that the mid plane card is present
by verifying the mid plane card EEPROM checksum.
Supports: diagStart, diagStop, diagRepetition.
cardZhoneType::ethernet(9) specific
-----------------------------------
midPlane(13)
- this diagnostic will verify that the mid plane card is present
by verifying the mid plane card EEPROM checksum.
Supports: diagStart, diagStop, diagRepetition.
cardZhoneType::hdsl2(10) specific
---------------------------------
ioCard(10)
- this diagnostic will verify that the I/O card is present by
verifying the I/O card EEPROM checksum.
Supports: diagStart, diagStop, diagRepetition.
mezzanineCard(11)
- this diagnostic will test that the mezzanine card is operational
by verifying the mezzanine card EEPROM checksum.
Supports: diagStart, diagStop, diagRepetition."
DEFVAL { selftest }
::= { zhoneCardDiagEntry 2 }
--
--
-- 1.3.6.1.4.1.5504.3.3.6.1.3
zhoneCardDiagAction OBJECT-TYPE
SYNTAX ZhoneDiagAction
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The diagAction field represents the diagnostic
operation to execute. Current supported actions are
as follows:
diagStart : begin diagnostics and initialize results.
diagStop : stop diagnostics if not yet complete.
diagSuspend: suspend diagnostics at current point.
diagResume : resume diagnostics from point of
suspension."
DEFVAL { diagStart }
::= { zhoneCardDiagEntry 3 }
--
--
-- 1.3.6.1.4.1.5504.3.3.6.1.4
zhoneCardDiagRepetition OBJECT-TYPE
SYNTAX Integer32 (0..10)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This field specifies the number of repetitions of diagnostics to execute.
The default value is 1.
NOTE: this field operates as an OR with the diagDuration field. If this
field is set to non-zero then the diagnostics will be executed
that amount of repetitions."
DEFVAL { 1 }
::= { zhoneCardDiagEntry 4 }
--
--
-- 1.3.6.1.4.1.5504.3.3.6.1.5
zhoneCardDiagDuration OBJECT-TYPE
SYNTAX Integer32 (0..600)
UNITS "seconds"
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This field specifies the duration of diagnostics to execute. The default
value is 60 seconds.
NOTE: this field operates as an OR with the diagRepetition field. If this
field is set to non-zero then the diagnostics will be executed that
amount of time."
DEFVAL { 60 }
::= { zhoneCardDiagEntry 5 }
--
--
-- 1.3.6.1.4.1.5504.3.3.6.1.6
zhoneCardDiagResult OBJECT-TYPE
SYNTAX ZhoneDiagResult
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This represents the overall diagnostic result."
::= { zhoneCardDiagEntry 6 }
--
--
-- 1.3.6.1.4.1.5504.3.3.6.1.7
zhoneCardDiagPassCount OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of diagnostics that executed successfully."
::= { zhoneCardDiagEntry 7 }
--
--
-- 1.3.6.1.4.1.5504.3.3.6.1.8
zhoneCardDiagFailCount OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of diagnostics that have failed."
::= { zhoneCardDiagEntry 8 }
--
--
-- 1.3.6.1.4.1.5504.3.3.6.1.9
zhoneCardDiagDetails OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (0..64))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The failure reason, if any, for the last diagnostic which has executed.
NOTE: An empty string indicates that no additional information is available."
::= { zhoneCardDiagEntry 9 }
--
--
-- 1.3.6.1.4.1.5504.3.3.6.1.10
zhoneCardDiagStartTime OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Starting date and time of last selftest execution."
::= { zhoneCardDiagEntry 10 }
--
--
-- 1.3.6.1.4.1.5504.3.3.6.1.11
zhoneCardDiagEndTime OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Ending date and time of last selftest execution."
::= { zhoneCardDiagEntry 11 }
--
--
-- 1.3.6.1.4.1.5504.3.3.6.1.12
zhoneCardDiagRowStatus OBJECT-TYPE
SYNTAX ZhoneRowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"In any case where a new row can be created either via
the cli or zms there will always be a proprietary mib
entity of type ZhoneRowStatus which has the basic
equivalence of the standard rowstatus object_id."
::= { zhoneCardDiagEntry 12 }
-- 1.3.6.1.4.1.5504.3.3.7
zhoneTacTestTable OBJECT-TYPE
SYNTAX SEQUENCE OF ZhoneTacTestEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table contains one entry for each tac
test channel available on Zhone devices. In the
initial release only the primary channel (1) is
supported. Future line cards may support the
second channel. If the second channel is supported
the row will be populated, if the second channel
is not supported a get will return no such instance.
"
::= { zhoneCard 7 }
-- 1.3.6.1.4.1.5504.3.3.7.1
zhoneTacTestEntry OBJECT-TYPE
SYNTAX ZhoneTacTestEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"One row per tac test channel."
INDEX { zhoneTacIndex }
::= { zhoneTacTestTable 1 }
ZhoneTacTestEntry ::=
SEQUENCE {
zhoneTacIndex
Integer32,
zhoneTacInterfaceIndex
InterfaceIndexOrZero,
zhoneTacTestMode
INTEGER,
zhoneTacTestId
INTEGER,
zhoneTacTestParam1
INTEGER,
zhoneTacTestParam2
INTEGER,
zhoneTacTestParam3
INTEGER,
zhoneTacTestParam4
INTEGER,
zhoneTacTestParam5
INTEGER
}
-- 1.3.6.1.4.1.5504.3.3.7.1.1
zhoneTacIndex OBJECT-TYPE
SYNTAX Integer32 (1..2)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This field is the index field for the tac test
channel which will be connected on the external
port. This device supports a maximum of two channels,
one or both channels may be supported by a device
depending on which lines cards are installed."
::= { zhoneTacTestEntry 1 }
--
-- 1.3.6.1.4.1.5504.3.3.7.1.2
zhoneTacInterfaceIndex OBJECT-TYPE
SYNTAX InterfaceIndexOrZero
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This field contains the InterfaceIndex of the physical line to
be tested. If no line is currently being tested this
value is 0.
The ability of a physical line type to support tac test may
vary depending on the line cards installed and the external test
equipment.
This field may not be modified when an tac test is
in progress as indicated by a non-zero value in this field
and the test mode set to one of tacModeLookIn, tacModeLookOut
or tacModeBridge"
DEFVAL { 0 }
::= { zhoneTacTestEntry 2 }
--
-- The current implementation supports mtacModeLookOut and mtacModeNone
-- only.
-- 1.3.6.1.4.1.5504.3.3.7.1.3
zhoneTacTestMode OBJECT-TYPE
SYNTAX INTEGER
{
mtacModeBridge(1),
mtacModeLookIn(2),
mtacModeLookOut(3),
mtacModeNone(4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This field is used to set the mtac test mode for a
given line. The options are:
mtacModeBridge - All traffic on the given line is bridged
across the mtac lines
mtacModeLookIn - All outbound traffic on the given line originates
exclusively to the mtac lines
mtacModeLookIn - All inbound traffic on the given line originates
exclusively to the mtac lines
mtacModeNone - No mtac test is in progress.
The mtac test mode may be changed only if the zhoneInterfaceIndex
is set, Otherwise it defaults to mtacModeNone.
And can be changed again by setting InterfaceIndex to non-zero values.
"
DEFVAL { mtacModeNone }
::= { zhoneTacTestEntry 3 }
-- 1.3.6.1.4.1.5504.3.3.7.1.4
zhoneTacTestId OBJECT-TYPE
SYNTAX INTEGER
{
none(1),
runAllTests(2),
abortTest(3),
calibration(4),
foreignDCVoltage(5),
foreignACVoltage(6),
dcLoopResistance(7),
threeElementInsulationResistance(8),
fiveElementInsulationResistance(9),
threeElementCapacitance(10),
receiverOffHook(11),
distanceToOpen(12),
foreignACCurrents(13),
ringerEquivalencyNumber(14),
dtmfAndPulseDigitMeasurement(15),
noiseMeasurement(16),
signalToNoiseRatio(17),
arbitrarySignalToneMeasurement(18),
toneGeneration(19),
transHybridLoss(20),
drawAndBreakDialTone(21),
inwardCurrent(22),
dcFeedSelf(23),
onAndOffHookSelfTest(24),
ringingSelfTest(25),
ringingMonitor(26),
meteringSelfTest(27),
transmissionSelfTest(28),
dialingSelfTest(29),
howlerTest(30),
fuseTest(31),
readLoopAndBatteryConditions(32)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object is only valid for Tac Cards which
support the new Legerity Suite of tests.
This object identifies which test is to
be run, or can be set to abort the current test.
Test results are sent to the zhoneTacTestResultsTable.
There are 3 Legerity software packages: Basic Test (VCP-BT),
Advanced Test (VCP-AT), and Advanced Test Plus (VCP-ATP).
We currently support Basic Test package.
The following lists which tests are supported in each
software package.
Calibration VCP-ATP
Foreign DC Voltage Test VCP-BT, VCP-AT, VCP-ATP
Foreign AC VoltageTest VCP-BT, VCP-AT, VCP-ATP
DC Loop Resistance Test VCP-BT, VCP-AT, VCP-ATP
Three-Element Insulation Resistance Test VCP-BT, VCP-AT, VCP-ATP
Five-Element Insulation Resistance Test VCP-ATP
Three-Element Capacitance Test VCP-BT, VCP-AT
Receiver Off-Hook Test VCP-BT, VCP-AT, VCP-ATP
Distance to Open Test VCP-BT, VCP-AT
Foreign AC Currents Test VCP-BT, VCP-AT
Ringer Equivalency Number Test VCP-BT, VCP-AT, VCP-ATP
DTMF and Pulse Digit Measurement Test VCP-BT, VCP-AT
Noise Measurement Test VCP-BT, VCP-AT, VCP-ATP
Signal to Noise Ratio Test VCP-ATP
Arbitrary Single Tone Measurement Test VCP-ATP
Tone Generation Test VCP-BT, VCP-AT
Trans-Hybrid Loss Test VCP-BT, VCP-AT, VCP-ATP
Draw and Break Dial Tone Test VCP-BT, VCP-AT
Inward Current Test VCP-ATP
DC Feed Self-Test VCP-BT, VCP-AT, VCP-ATP
On/Off Hook Self-Test VCP-BT, VCP-AT, VCP-ATP
Ringing Self-Test VCP-BT, VCP-AT, VCP-ATP
Ringing Monitor Test VCP-BT, VCP-AT, VCP-ATP
Metering Self-Test VCP-BT, VCP-AT
Transmission Self-Test VCP-BT, VCP-AT, VCP-ATP
Dialing Sef Test VCP-BT, VCP-AT
Howler Test VCP-BT, VCP-AT
Fuse Test VCP-ATP
Read Loop and Battery Conditions VCP-BT, VCP-AT, VCP-ATP
"
DEFVAL { none }
::= { zhoneTacTestEntry 4 }
-- 1.3.6.1.4.1.5504.3.3.7.1.5
zhoneTacTestParam1 OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Optional Test Parameter #1"
DEFVAL { 0 }
::= { zhoneTacTestEntry 5 }
-- 1.3.6.1.4.1.5504.3.3.7.1.6
zhoneTacTestParam2 OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Optional Test Paramerter #2"
DEFVAL { 0 }
::= { zhoneTacTestEntry 6 }
-- 1.3.6.1.4.1.5504.3.3.7.1.7
zhoneTacTestParam3 OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Optional Test Parameter #3"
DEFVAL { 0 }
::= { zhoneTacTestEntry 7 }
-- 1.3.6.1.4.1.5504.3.3.7.1.8
zhoneTacTestParam4 OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Optional Test Parameter #4"
DEFVAL { 0 }
::= { zhoneTacTestEntry 8 }
-- 1.3.6.1.4.1.5504.3.3.7.1.9
zhoneTacTestParam5 OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Optional Test Parameter #5
Value:
0x00000001 Force Line-Test mode"
DEFVAL { 0 }
::= { zhoneTacTestEntry 9 }
-- 1.3.6.1.4.1.5504.3.3.12
zhoneTacTestResultsTable OBJECT-TYPE
SYNTAX SEQUENCE OF ZhoneTacTestResultsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Table of Tac Test Results objects. Indexed by same index
as zhoneTacTestTable.
This table is only valid for Tac cards which support
the Legerity Suite of tests."
::= { zhoneCard 12 }
-- 1.3.6.1.4.1.5504.3.3.12.1
zhoneTacTestResultsEntry OBJECT-TYPE
SYNTAX ZhoneTacTestResultsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Entry of Test Results objects. Indexed by same index
as zhoneTacTestEntry.
This entry is only valid for Tac cards which support
the Legerity Suite of tests."
INDEX { zhoneTacIndex }
::= { zhoneTacTestResultsTable 1 }
ZhoneTacTestResultsEntry ::=
SEQUENCE {
zhoneTacTestResultsTimeStarted
TimeTicks,
zhoneTacTestResultsTimeEnded
TimeTicks,
zhoneTacTestResultStatus
INTEGER,
zhoneTacTestResultsOutput
OCTET STRING
}
-- 1.3.6.1.4.1.5504.3.3.12.1.1
zhoneTacTestResultsTimeStarted OBJECT-TYPE
SYNTAX TimeTicks
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Description."
::= { zhoneTacTestResultsEntry 1 }
-- 1.3.6.1.4.1.5504.3.3.12.1.2
zhoneTacTestResultsTimeEnded OBJECT-TYPE
SYNTAX TimeTicks
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Description."
::= { zhoneTacTestResultsEntry 2 }
-- 1.3.6.1.4.1.5504.3.3.12.1.3
zhoneTacTestResultStatus OBJECT-TYPE
SYNTAX INTEGER
{
testNotStarted(1),
testInProgress(2),
testCompleted(3),
testAborted(4),
testNotSupported(5)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Contains test results."
REFERENCE
"Contains the test status."
::= { zhoneTacTestResultsEntry 3 }
-- 1.3.6.1.4.1.5504.3.3.12.1.4
zhoneTacTestResultsOutput OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (1..8000))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"For Legerity Test Suite, results of test(s) are
output to this object as one string, separated by
UNIX '/n' for newline characters and terminated by
the NULL character.
This test results will persist until the next test
is run or until tac card reboot."
::= { zhoneTacTestResultsEntry 4 }
-- 1.3.6.1.4.1.5504.3.3.13
zhoneTacTestTraps OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Traps for the tac system."
::= { zhoneCard 13 }
-- 1.3.6.1.4.1.5504.3.3.13.0
zhoneRingerTraps OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Traps associated with ring generator.
Traps should be added below - the .0
on this entry is required."
::= { zhoneTacTestTraps 0 }
-- 1.3.6.1.4.1.5504.3.3.13.0.1
zhoneRingerStatusAlarm NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"This trap occurs when a ring signal fails to be detected,
or when it re-starts after failure."
::= { zhoneRingerTraps 1 }
-- 1.3.6.1.4.1.5504.3.3.13.0.2
zhoneRingerBusFaultAlarm NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"This trap occurs when a fault in the ringer power bus is
detected. Such fault may be caused by the possible shortage
in the POTS or DSL line."
::= { zhoneRingerTraps 2 }
-- 1.3.6.1.4.1.5504.6.11.1
zhoneCardDiagObjects OBJECT-GROUP
OBJECTS { zhoneCardDiagNextIndex, zhoneCardDiagType, zhoneCardDiagAction, zhoneCardDiagRepetition, zhoneCardDiagDuration,
zhoneCardDiagResult, zhoneCardDiagPassCount, zhoneCardDiagFailCount, zhoneCardDiagDetails, zhoneCardDiagStartTime,
zhoneCardDiagEndTime, zhoneCardDiagRowStatus }
STATUS current
DESCRIPTION
"This group contains objects associated with Zhone Card
Diagnostics"
::= { zhoneCardDiagnosticsModule 1 }
-- 1.3.6.1.4.1.5504.6.11.2
zhoneTacTestObjects OBJECT-GROUP
OBJECTS { zhoneTacInterfaceIndex, zhoneTacTestMode, zhoneTacTestId, zhoneTacTestResultsTimeStarted, zhoneTacTestResultsTimeEnded,
zhoneTacTestResultStatus, zhoneTacTestResultsOutput }
STATUS current
DESCRIPTION
"This group contains objects associated with initiating
tac tests"
::= { zhoneCardDiagnosticsModule 2 }
END
--
-- genCardDiagnostics.mib
--