-- Copyright (C) 2007-2010 by Zhone Technologies. All Rights Reserved.
-- ======================================================================
-- == ==
-- == ZHN-SYSMON-MIB ==
-- == ==
-- == Copyright (C) 2007-2010 Zhone Technologies, Inc. ==
-- == Confidential, Unpublished Property of Zhone Technologies. ==
-- == Rights Reserved Under the Copyright Laws of the United States. ==
-- == ==
-- ======================================================================
ZHNSYSMON DEFINITIONS ::= BEGIN
IMPORTS
MODULE-IDENTITY, OBJECT-TYPE, Unsigned32, NOTIFICATION-TYPE
FROM SNMPv2-SMI
RowStatus, DisplayString, DateAndTime
FROM SNMPv2-TC
zhoneWtn
FROM Zhone;
zhnSysMon MODULE-IDENTITY
LAST-UPDATED "201009240000Z" -- Aug 24, 2010
ORGANIZATION "Zhone Technologies
MIB Working Group
Other information about group editing the MIB"
CONTACT-INFO "Zhone Technologies, Inc.
Florida Design Center
8545 126th Avenue North
Largo, FL 33773
www.zhone.com
General Comments to: largo-mibwg-team@zhone.com"
DESCRIPTION
"This MIB contains objects that are used by the System
Monitoring function.
==============================================================
== ==
== Copyright (C) 2007-2010 Zhone Technologies, Inc. ==
== ==
=============================================================="
REVISION "201009240000Z" -- Aug 24, 2010
DESCRIPTION "Added zhnSysMonAlarmTypes:
onBatteryPower2(33),
batteryPowerLow2(34),
replaceBattery2(35),
batteryRemoved2(36),
doorOpened(37)"
REVISION "201006210000Z" -- Jun 21, 2010
DESCRIPTION "Added zhnSysMonAlarmType varbind to the zhnSysMonAlarmSetEvent and
zhnSysMonAlarmClearEvent NOTIFICATION-TYPEs."
REVISION "200912140000Z" -- Dec 14, 2009
DESCRIPTION "Added new alarm types for CPEs with battery-backup units. Also
added a new NOTIFICATION-TYPE for database configuration changes."
REVISION "200905200000Z" -- May 20, 2009
DESCRIPTION "Change MODULE-IDENTITY to zhnSysMon and removed unsupported objects.
Since this MIB has not yet been published, the unsupported objects
were removed, rather than deprecated."
REVISION "200904060000Z" -- April 6, 2009
DESCRIPTION "Changed pwLOFS alarm to pwLOP "
REVISION "200901060000Z" -- January 6, 2009
DESCRIPTION "Added new alarm types for PW Clock Stability alarm"
REVISION "200805210000Z" -- May 21, 2008
DESCRIPTION "Added new alarm types for PW and T1/E1 interfaces"
REVISION "200711260000Z" -- November 26, 2007
DESCRIPTION "Changed Zhone OID to zhoneWtn OID"
REVISION "200612260000Z" -- December 26, 2006
DESCRIPTION "Added:
- line power config table
- SysMon ready and line power config update notifications
- internal use use 'wanData' alarm severity"
REVISION "200612120000Z" -- December 12, 2006
DESCRIPTION "zhnSysMonAlarmTable, zhnSysMonAlarmSetEvent, zhnSysMonAlarmClearEvent:
- Removed zhnSysMonAlarmInstance, added zhnSysMonAlarmInterfaceName
zhnSysMonTestTable, zhnSysMonTestStartEvent, zhnSysMonTestStopEvent:
- Removed zhnSysMonTestInstance, added zhnSysMonTestInterfaceName"
REVISION "200611170000Z" -- November 17, 2006
DESCRIPTION "- Added notification definitions,
- Reworked Test Table,
- Had to change MAX-ACCESS of objects included in notifications
from not-accessible to read-create"
REVISION "200608310000Z" -- August 31, 2006
DESCRIPTION "Initial release."
::= { zhoneWtn 1 }
zhnSysMonNotifications OBJECT IDENTIFIER ::= { zhnSysMon 0 }
zhnSysMonObjects OBJECT IDENTIFIER ::= { zhnSysMon 1 }
zhnSysMonConformance OBJECT IDENTIFIER ::= { zhnSysMon 2 }
-- ***************************************************************
--
-- Alarm Table
--
zhnSysMonAlarmTable OBJECT-TYPE
SYNTAX SEQUENCE OF ZhnSysMonAlarmEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "This table contains the current system alarms."
::= { zhnSysMonObjects 1 }
zhnSysMonAlarmEntry OBJECT-TYPE
SYNTAX ZhnSysMonAlarmEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An entry in the zhnSysMonAlarmTable."
INDEX { zhnSysMonAlarmType,
zhnSysMonAlarmSeverity,
zhnSysMonAlarmInterfaceName }
::= { zhnSysMonAlarmTable 1 }
ZhnSysMonAlarmEntry ::=
SEQUENCE {
zhnSysMonAlarmType INTEGER,
zhnSysMonAlarmSeverity INTEGER,
zhnSysMonAlarmInterfaceName DisplayString,
zhnSysMonAlarmDescription DisplayString,
zhnSysMonAlarmRowStatus RowStatus
}
zhnSysMonAlarmType OBJECT-TYPE
SYNTAX INTEGER {
tempThresholdExceeded(1),
mainPowerLoss(2),
secondaryPowerLoss(3),
lowPowerMode(4),
selftestFailed(5),
interfaceDown(6),
processFailed(7),
pwDown(8),
pwDeleted(9),
pwMisconnected(10),
pwLOP(11),
pwLateFrame(12),
pwMalformedFrame(13),
pwJitterBufferOverrun(14),
dsx1RcvYellow(15),
dsx1XmtYellow(16),
dsx1RcvAIS(17),
dsx1XmtAIS(18),
dsx1LossOfFrame(19),
dsx1LossOfSignal(20),
dsx1LoopbackState(21),
dsx1TestingState(22),
pwClockStability(23),
pwClockHoldover(24),
pwClockStabilityIdle(25),
pwClockStabilityAcquisition(26),
pwClockStabilityTracking1(27),
pwClockStabilityRecovery(28),
onBatteryPower(29),
batteryPowerLow(30),
replaceBattery(31),
batteryRemoved(32),
onBatteryPower2(33),
batteryPowerLow2(34),
replaceBattery2(35),
batteryRemoved2(36),
doorOpened(37),
other(99)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION "The type of alarm currently posted."
::= { zhnSysMonAlarmEntry 1 }
zhnSysMonAlarmSeverity OBJECT-TYPE
SYNTAX INTEGER {
minor(1),
major(2),
critical(3),
wanData(4) -- internal use only
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION "The severity of the alarm."
::= { zhnSysMonAlarmEntry 2 }
zhnSysMonAlarmInterfaceName OBJECT-TYPE
SYNTAX DisplayString (SIZE (1..255))
MAX-ACCESS read-create
STATUS current
DESCRIPTION "This object specifies the interface name (e.g., wlan0),
or instance (e.g., sensor 1, primary power source 3)
associated with the alarm."
::= { zhnSysMonAlarmEntry 3 }
zhnSysMonAlarmDescription OBJECT-TYPE
SYNTAX DisplayString (SIZE (1..255))
MAX-ACCESS read-create
STATUS current
DESCRIPTION "This object is a textual description of an alarm type."
::= { zhnSysMonAlarmEntry 4 }
zhnSysMonAlarmRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION "The SNMP RowStatus of the current row."
::= { zhnSysMonAlarmEntry 5 }
-- ***************************************************************
--
-- Test Table
--
zhnSysMonTestTable OBJECT-TYPE
SYNTAX SEQUENCE OF ZhnSysMonTestEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "This table contains the current system tests."
::= { zhnSysMonObjects 2 }
zhnSysMonTestEntry OBJECT-TYPE
SYNTAX ZhnSysMonTestEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An entry in the zhnSysMonTestTable."
INDEX { zhnSysMonTestType,
zhnSysMonTestInterfaceName }
::= { zhnSysMonTestTable 1 }
ZhnSysMonTestEntry ::=
SEQUENCE {
zhnSysMonTestType INTEGER,
zhnSysMonTestInterfaceName DisplayString,
zhnSysMonTestRowStatus RowStatus
}
zhnSysMonTestType OBJECT-TYPE
SYNTAX INTEGER {
loopback(1),
led(2)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION "The type of test currently running."
::= { zhnSysMonTestEntry 1 }
zhnSysMonTestInterfaceName OBJECT-TYPE
SYNTAX DisplayString (SIZE (1..255))
MAX-ACCESS read-create
STATUS current
DESCRIPTION "This object specifies the interface name (e.g., wlan0)
associated with the test."
::= { zhnSysMonTestEntry 2 }
zhnSysMonTestRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION "The SNMP RowStatus of the current row."
::= { zhnSysMonTestEntry 3 }
-- ***************************************************************
--
-- Temperature Sensor Table
--
zhnSysMonTempSensorTable OBJECT-TYPE
SYNTAX SEQUENCE OF ZhnSysMonTempSensorEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "This table contains the system temperature sensors."
::= { zhnSysMonObjects 3 }
zhnSysMonTempSensorEntry OBJECT-TYPE
SYNTAX ZhnSysMonTempSensorEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An entry in the zhnSysMonTempSensorTable."
INDEX { zhnSysMonTempSensorId }
::= { zhnSysMonTempSensorTable 1 }
ZhnSysMonTempSensorEntry ::=
SEQUENCE {
zhnSysMonTempSensorId Unsigned32,
zhnSysMonTempSensorRowStatus RowStatus,
zhnSysMonTempSensorCurr DisplayString,
zhnSysMonTempSensorOS DisplayString,
zhnSysMonTempSensorHyst DisplayString,
zhnSysMonTempSensorName DisplayString
}
zhnSysMonTempSensorId OBJECT-TYPE
SYNTAX Unsigned32 (0..9999)
MAX-ACCESS read-create
STATUS current
DESCRIPTION "This object specifies the reference index
for each detected temperature sensor."
::= { zhnSysMonTempSensorEntry 1 }
zhnSysMonTempSensorRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION "The SNMP RowStatus of the current row."
::= { zhnSysMonTempSensorEntry 2 }
zhnSysMonTempSensorCurr OBJECT-TYPE
SYNTAX DisplayString (SIZE (1..8))
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The current temperature reported by the
sensor in degrees Celcius."
::= { zhnSysMonTempSensorEntry 3 }
zhnSysMonTempSensorOS OBJECT-TYPE
SYNTAX DisplayString (SIZE (1..8))
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The configured Overtemperature Shutdown (OS)
for the sensor in degrees Celcius. This is
the temperature alarm threshold"
::= { zhnSysMonTempSensorEntry 4 }
zhnSysMonTempSensorHyst OBJECT-TYPE
SYNTAX DisplayString (SIZE (1..8))
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The configured temperature hysteresis for
the sensor in degrees Celcius. This is
the temperature at which the alarm condition
goes away."
::= { zhnSysMonTempSensorEntry 5 }
zhnSysMonTempSensorName OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
MAX-ACCESS read-write
STATUS current
DESCRIPTION "A textual string describing the sensor."
::= { zhnSysMonTempSensorEntry 6 }
-- ***************************************************************
--
-- Line Power Table
--
zhnSysMonLinePowerTable OBJECT-TYPE
SYNTAX SEQUENCE OF ZhnSysMonLinePowerEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "This table contains the line power configuration."
::= { zhnSysMonObjects 4 }
zhnSysMonLinePowerEntry OBJECT-TYPE
SYNTAX ZhnSysMonLinePowerEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An entry in the zhnSysMonLinePowerTable."
INDEX { zhnSysMonLinePowerLineNumber }
::= { zhnSysMonLinePowerTable 1 }
ZhnSysMonLinePowerEntry ::=
SEQUENCE {
zhnSysMonLinePowerLineNumber Unsigned32,
zhnSysMonLinePowerStatus INTEGER,
zhnSysMonLinePowerRowStatus RowStatus
}
zhnSysMonLinePowerLineNumber OBJECT-TYPE
SYNTAX Unsigned32 (1..9999)
MAX-ACCESS read-create
STATUS current
DESCRIPTION "This object specifies the line number
for each primary power source."
::= { zhnSysMonLinePowerEntry 1 }
zhnSysMonLinePowerStatus OBJECT-TYPE
SYNTAX INTEGER {
enabled(1),
disabled(2)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION "The current power configuration status of the line identified
by zhnSysMonLinePowerLineNumber. A status of enabled(1)
indicates that the line is being monitored as a primary
power source for the unit (i.e., an alarm is posted if
it fails)."
DEFVAL { enabled }
::= { zhnSysMonLinePowerEntry 2 }
zhnSysMonLinePowerRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION "The SNMP RowStatus of the current row."
::= { zhnSysMonLinePowerEntry 3 }
-- ***************************************************************
--
-- SysMon Notifications
--
zhnSysMonAlarmSetEvent NOTIFICATION-TYPE
OBJECTS { zhnSysMonAlarmType,
zhnSysMonAlarmSeverity,
zhnSysMonAlarmInterfaceName,
zhnSysMonAlarmDescription
}
STATUS current
DESCRIPTION
"A zhnSysMonAlarmSetEvent notification is sent when an
alarm condition is detected by a system component.
The System Monitor is informed of the alarm and
generates the alarm set notification.
The objects in the notification correspond to the values
in a row instance of in the zhnSysMonAlarmTable."
::= { zhnSysMonNotifications 1 }
zhnSysMonAlarmClearEvent NOTIFICATION-TYPE
OBJECTS { zhnSysMonAlarmType,
zhnSysMonAlarmSeverity,
zhnSysMonAlarmInterfaceName,
zhnSysMonAlarmDescription
}
STATUS current
DESCRIPTION
"A zhnSysMonAlarmClearEvent notification is sent when an
alarm condition is cleared by a system component.
The System Monitor is informed of the alarm state and
generates the alarm clear notification.
The objects in the notification correspond to the values
in a row instance of in the zhnSysMonAlarmTable."
::= { zhnSysMonNotifications 2 }
zhnSysMonTestStartEvent NOTIFICATION-TYPE
OBJECTS { zhnSysMonTestType,
zhnSysMonTestInterfaceName
}
STATUS current
DESCRIPTION
"A zhnSysMonTestStartEvent notification is sent by
any system component that begins a test.
The objects in the notification correspond to the values
in a row instance of in the zhnSysMonTestTable."
::= { zhnSysMonNotifications 3 }
zhnSysMonTestStopEvent NOTIFICATION-TYPE
OBJECTS { zhnSysMonTestType,
zhnSysMonTestInterfaceName
}
STATUS current
DESCRIPTION
"A zhnSysMonTestStopEvent notification is sent by
any system component that ends a test.
The objects in the notification correspond to the values
in a row instance of in the zhnSysMonTestTable."
::= { zhnSysMonNotifications 4 }
zhnSysMonTempSensorCfgUpdateEvent NOTIFICATION-TYPE
OBJECTS { zhnSysMonTempSensorId,
zhnSysMonTempSensorOS,
zhnSysMonTempSensorHyst
}
STATUS current
DESCRIPTION
"A zhnSysMonTempCfgUpdateEvent notification is sent by
the System Monitor whenever it reconfigures a
temperature sensor.
The objects in the notification correspond to the values
in a row instance of in the zhnSysMonTempSensorTable."
::= { zhnSysMonNotifications 5 }
zhnSysMonLinePowerCfgUpdateEvent NOTIFICATION-TYPE
OBJECTS { zhnSysMonLinePowerLineNumber,
zhnSysMonLinePowerStatus
}
STATUS current
DESCRIPTION
"A zhnSysMonLinePowerCfgUpdateEvent notification is sent by
the System Monitor whenever it reconfigures a power source
line.
The objects in the notification correspond to the values
in a row instance of in the zhnSysMonLinePowerTable."
::= { zhnSysMonNotifications 6 }
zhnSysMonReadyEvent NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"A zhnSysMonReadyEvent notification is sent by the
System Monitor whenever it has completed initialization
and is ready to accept requests."
::= { zhnSysMonNotifications 7 }
zhnSysMonConfigChangeEvent NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"A zhnSysMonConfigChangeEvent notification is generated
whenever the persistent database is saved."
::= { zhnSysMonNotifications 8 }
END