Webio-ANx-MIB DEFINITIONS ::= BEGIN
----------------------------------------------------------------
-- Revison: 1.20
----------------------------------------------------------------
-- 02.06.2005 #57601/3/4, WebThermometer
-- Trap NMS annotations
----------------------------------------------------------------
-- Revison: 1.19
----------------------------------------------------------------
-- 18.04.2005 HTTP-Port adjustable
--
----------------------------------------------------------------
-- Revison: 1.18
----------------------------------------------------------------
-- 14.07.2004 Separation into product families
--
----------------------------------------------------------------
-- Revison: 1.17
----------------------------------------------------------------
-- 28.06.2004 #57630/1/2, Webio Digital
-- Neu: Puls Mode
----------------------------------------------------------------
-- Revison: 1.16
----------------------------------------------------------------
-- 16.04.2004 New: #57632, Webio Digital EA24x24
--
-- #57630/1, Webio Digital EA12x12
-- New:
-- wtWebioEA12x12InputCounterClear
----------------------------------------------------------------
-- Revison: 1.15
----------------------------------------------------------------
-- 27.02.2004 #57630/1, Webio Digital EA12x12
-- New:
-- Length changed to 32 Bit:
-- wtWebioEA12x12InputValue
-- wtWebioEA12x12OutputValue
-- wtWebioEA12x12LoadControlView
-- wtWebioEA12x12LCShutDownView
-- wtWebioEA12x12SetOutput
-- wtWebioEA12x12AlarmInputTrigger
-- wtWebioEA12x12AlarmOutputTrigger
-- wtWebioEA12x12PortOutputSafetyState
----------------------------------------------------------------
-- Revison: 1.14
----------------------------------------------------------------
-- 16.02.2004 #57630/1, Webio Digital EA12x12
-- New:
-- Text: Location, Contact
-- SNMP: ColdStart, WarmStart, ComunityString Read/RW
-- Alarm: ColdStart / WarmStart trigger
--
-- #57601, 1xWebThermometer
-- #57603, 2xWebThermometer
-- #57604, 8xWebThermometer
-- New:
-- Alarm Hysteresis
-- Alarm Clear Traps and Mails
----------------------------------------------------------------
-- Revison: 1.13
----------------------------------------------------------------
-- 05.02.2004 #57601, 1xWebThermometer
-- #57603, 2xWebThermometer
-- #57604, 8xWebThermometer
-- New:
-- Text: Location, Contact
-- SNMP: ColdStart, WarmStart, ComunityString Read/RW
-- Alarm: ColdStart / WarmStart trigger
----------------------------------------------------------------
-- Revison: 1.12
----------------------------------------------------------------
-- 05.11.2003 #57601, 1xWebThermometer
-- #57603, 2xWebThermometer
-- #57604, 8xWebThermometer
-- New features:
-- Mail : Option CSV attachment
-- Port : Offset calibration
-- Alarm : TCP Client mode
----------------------------------------------------------------
-- Revison: 1.11
----------------------------------------------------------------
-- 28.10.2003 #57630/1, Webio Digital EA12x12
-- New features:
-- Alarm : TCP Client mode
-- Inputs: Puls filter
----------------------------------------------------------------
-- Revison: 1.10
----------------------------------------------------------------
-- 22.07.2003 #57630, Webio Digital EA12x12
-- New navigation tree, new binary modes
--
----------------------------------------------------------------
-- Revison: 1.09
----------------------------------------------------------------
-- 24.03.2003 Trap Enterprise (Type 1, 2) corrected
----------------------------------------------------------------
-- Revison: 1.08
----------------------------------------------------------------
-- 04.03.2003 reconciled the language versions DE/US
----------------------------------------------------------------
-- Revison: 1.07
----------------------------------------------------------------
-- 25.02.2003 Correction: wtWebioEA12x12LoadControl
----------------------------------------------------------------
-- Revison: 1.06
----------------------------------------------------------------
-- 24.02.2003 New:
-- #57630, Webio EA12x12, LoadControl Group
-- Correction: Trap variable names
----------------------------------------------------------------
-- Revison: 1.05
----------------------------------------------------------------
-- 21.01.2003 New:
-- #57630, Webio EA12x12
----------------------------------------------------------------
-- Revison: 1.04
----------------------------------------------------------------
-- 02.01.2003 New:
-- #57601, 1xWebThermometer
-- #57603, 2xWebThermometer, 8 alarms
----------------------------------------------------------------
-- Revison: 1.03
----------------------------------------------------------------
-- 21.11.2002 New:
-- #57604, 2xWebThermometer, BOOTP, StartupSite
-- #57603, 8xWebThermometer, BOOTP, StartupSite
----------------------------------------------------------------
-- Revison: 1.02
----------------------------------------------------------------
-- 26.07.2002 New:
-- #57604, 2xWebThermometer
-- #57603, 8xWebThermometer
--
IMPORTS
OBJECT-TYPE FROM RFC-1212
TRAP-TYPE FROM RFC-1215
DisplayString, PhysAddress FROM RFC1213-MIB
enterprises, TimeTicks, IpAddress, NetworkAddress FROM RFC1155-SMI;
-- IpAddress ::=
-- [APPLICATION 0]
-- IMPLICIT OCTET STRING (SIZE (4))
-- Counter ::=
-- [APPLICATION 1]
-- IMPLICIT INTEGER (0..4294967295)
-- Gauge ::=
-- [APPLICATION 2]
-- IMPLICIT INTEGER (0..4294967295)
-- TimeTicks ::=
-- [APPLICATION 3]
-- IMPLICIT INTEGER (0..4294967295)
-- DisplayString ::= OCTET STRING
-- PhysAddress ::= OCTET STRING
-- internet OBJECT IDENTIFIER ::= { iso org(3) dod(6) 1 }
-- privat OBJECT IDENTIFIER ::= { internet 4 }
-- enterprises OBJECT IDENTIFIER ::= { privat 1 }
-- Wiesemann & Theis Com-Server MIB
wut OBJECT IDENTIFIER ::= { enterprises 5040 }
wtComServer OBJECT IDENTIFIER ::= { wut 1 }
wtWebio OBJECT IDENTIFIER ::= { wtComServer 2 }
-- wtWebio Tree
wtWebioAn8 OBJECT IDENTIFIER ::= { wtWebio 1 }
wtWebioAn2 OBJECT IDENTIFIER ::= { wtWebio 2 }
wtWebioAn1 OBJECT IDENTIFIER ::= { wtWebio 3 }
-- wtWebioAn8 Tree
wtWebioAn8Temp OBJECT IDENTIFIER ::= { wtWebioAn8 1 }
wtWebioAn8SessCntrl OBJECT IDENTIFIER ::= { wtWebioAn8 2 }
wtWebioAn8Config OBJECT IDENTIFIER ::= { wtWebioAn8 3 }
-- wtWebioAn8Config Tree
wtWebioAn8Device OBJECT IDENTIFIER ::= { wtWebioAn8Config 1 }
wtWebioAn8Ports OBJECT IDENTIFIER ::= { wtWebioAn8Config 2 }
wtWebioAn8Manufact OBJECT IDENTIFIER ::= { wtWebioAn8Config 3 }
-- wtWebioAn8Device Tree
wtWebioAn8Network OBJECT IDENTIFIER ::= { wtWebioAn8Device 1 }
wtWebioAn8Text OBJECT IDENTIFIER ::= { wtWebioAn8Device 2 }
wtWebioAn8TimeDate OBJECT IDENTIFIER ::= { wtWebioAn8Device 3 }
wtWebioAn8MailAdmin OBJECT IDENTIFIER ::= { wtWebioAn8Device 4 }
wtWebioAn8Alarm OBJECT IDENTIFIER ::= { wtWebioAn8Device 5 }
wtWebioAn8Datalogger OBJECT IDENTIFIER ::= { wtWebioAn8Device 6 }
wtWebioAn8Protocol OBJECT IDENTIFIER ::= { wtWebioAn8Device 7 }
wtWebioAn8Enable OBJECT IDENTIFIER ::= { wtWebioAn8Device 8 }
wtWebioAn8Startup OBJECT IDENTIFIER ::= { wtWebioAn8Device 9 }
-- wtWebioAn8TimeDate Tree
wtWebioAn8TimeZone OBJECT IDENTIFIER ::= { wtWebioAn8TimeDate 1 }
wtWebioAn8TimeServer OBJECT IDENTIFIER ::= { wtWebioAn8TimeDate 2 }
wtWebioAn8DeviceClock OBJECT IDENTIFIER ::= { wtWebioAn8TimeDate 3 }
-- wtWebioAn8Protocol Group
wtWebioAn8PrtclUDP OBJECT IDENTIFIER ::= { wtWebioAn8Protocol 1 }
wtWebioAn8PrtclSNMP OBJECT IDENTIFIER ::= { wtWebioAn8Protocol 2 }
wtWebioAn8PrtclHTTP OBJECT IDENTIFIER ::= { wtWebioAn8Protocol 3 }
-- wtWebioAn2 Tree
wtWebioAn2Temp OBJECT IDENTIFIER ::= { wtWebioAn2 1 }
wtWebioAn2SessCntrl OBJECT IDENTIFIER ::= { wtWebioAn2 2 }
wtWebioAn2Config OBJECT IDENTIFIER ::= { wtWebioAn2 3 }
-- wtWebioAn2Config Tree
wtWebioAn2Device OBJECT IDENTIFIER ::= { wtWebioAn2Config 1 }
wtWebioAn2Ports OBJECT IDENTIFIER ::= { wtWebioAn2Config 2 }
wtWebioAn2Manufact OBJECT IDENTIFIER ::= { wtWebioAn2Config 3 }
-- wtWebioAn2Device Tree
wtWebioAn2Network OBJECT IDENTIFIER ::= { wtWebioAn2Device 1 }
wtWebioAn2Text OBJECT IDENTIFIER ::= { wtWebioAn2Device 2 }
wtWebioAn2TimeDate OBJECT IDENTIFIER ::= { wtWebioAn2Device 3 }
wtWebioAn2MailAdmin OBJECT IDENTIFIER ::= { wtWebioAn2Device 4 }
wtWebioAn2Alarm OBJECT IDENTIFIER ::= { wtWebioAn2Device 5 }
wtWebioAn2Datalogger OBJECT IDENTIFIER ::= { wtWebioAn2Device 6 }
wtWebioAn2Protocol OBJECT IDENTIFIER ::= { wtWebioAn2Device 7 }
wtWebioAn2Enable OBJECT IDENTIFIER ::= { wtWebioAn2Device 8 }
wtWebioAn2Startup OBJECT IDENTIFIER ::= { wtWebioAn2Device 9 }
-- wtWebioAn2TimeDate Tree
wtWebioAn2TimeZone OBJECT IDENTIFIER ::= { wtWebioAn2TimeDate 1 }
wtWebioAn2TimeServer OBJECT IDENTIFIER ::= { wtWebioAn2TimeDate 2 }
wtWebioAn2DeviceClock OBJECT IDENTIFIER ::= { wtWebioAn2TimeDate 3 }
-- wtWebioAn2Protocol Group
wtWebioAn2PrtclUDP OBJECT IDENTIFIER ::= { wtWebioAn2Protocol 1 }
wtWebioAn2PrtclSNMP OBJECT IDENTIFIER ::= { wtWebioAn2Protocol 2 }
wtWebioAn2PrtclHTTP OBJECT IDENTIFIER ::= { wtWebioAn2Protocol 3 }
-- wtWebioAn1 Tree
wtWebioAn1Temp OBJECT IDENTIFIER ::= { wtWebioAn1 1 }
wtWebioAn1SessCntrl OBJECT IDENTIFIER ::= { wtWebioAn1 2 }
wtWebioAn1Config OBJECT IDENTIFIER ::= { wtWebioAn1 3 }
-- wtWebioAn1Config Tree
wtWebioAn1Device OBJECT IDENTIFIER ::= { wtWebioAn1Config 1 }
wtWebioAn1Ports OBJECT IDENTIFIER ::= { wtWebioAn1Config 2 }
wtWebioAn1Manufact OBJECT IDENTIFIER ::= { wtWebioAn1Config 3 }
-- wtWebioAn1Device Tree
wtWebioAn1Network OBJECT IDENTIFIER ::= { wtWebioAn1Device 1 }
wtWebioAn1Text OBJECT IDENTIFIER ::= { wtWebioAn1Device 2 }
wtWebioAn1TimeDate OBJECT IDENTIFIER ::= { wtWebioAn1Device 3 }
wtWebioAn1MailAdmin OBJECT IDENTIFIER ::= { wtWebioAn1Device 4 }
wtWebioAn1Alarm OBJECT IDENTIFIER ::= { wtWebioAn1Device 5 }
wtWebioAn1Datalogger OBJECT IDENTIFIER ::= { wtWebioAn1Device 6 }
wtWebioAn1Protocol OBJECT IDENTIFIER ::= { wtWebioAn1Device 7 }
wtWebioAn1Enable OBJECT IDENTIFIER ::= { wtWebioAn1Device 8 }
wtWebioAn1Startup OBJECT IDENTIFIER ::= { wtWebioAn1Device 9 }
-- wtWebioAn1TimeDate Tree
wtWebioAn1TimeZone OBJECT IDENTIFIER ::= { wtWebioAn1TimeDate 1 }
wtWebioAn1TimeServer OBJECT IDENTIFIER ::= { wtWebioAn1TimeDate 2 }
wtWebioAn1DeviceClock OBJECT IDENTIFIER ::= { wtWebioAn1TimeDate 3 }
-- wtWebioAn1Protocol Group
wtWebioAn1PrtclUDP OBJECT IDENTIFIER ::= { wtWebioAn1Protocol 1 }
wtWebioAn1PrtclSNMP OBJECT IDENTIFIER ::= { wtWebioAn1Protocol 2 }
wtWebioAn1PrtclHTTP OBJECT IDENTIFIER ::= { wtWebioAn1Protocol 3 }
--------------------------------------------------------------------------------
--------------------------------------------------------------------------------
--------------------------------------------------------------------------------
-- Webio Area
-- All queries are passed from the ComServer module to the Webio Platform
--------------------------------------------------------------------------------
--------------------------------------------------------------------------------
--------------------------------------------------------------------------------
-- wtWebioAn8Temp Group
------------------------
wtWebioAn8Sensors OBJECT-TYPE
SYNTAX INTEGER (1..8)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Number of temperature sensors"
::= { wtWebioAn8Temp 1 }
-- Interface Table
wtWebioAn8SensorTable OBJECT-TYPE
SYNTAX SEQUENCE OF WtWebioAn8SensorEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"List of sensors."
::= { wtWebioAn8Temp 2 }
wtWebioAn8SensorEntry OBJECT-TYPE
SYNTAX WtWebioAn8SensorEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Temperature sensor numbers."
INDEX { wtWebioAn8SensorNo }
::= { wtWebioAn8SensorTable 1 }
WtWebioAn8SensorEntry ::= SEQUENCE {
wtWebioAn8SensorNo INTEGER (1..8)
}
wtWebioAn8SensorNo OBJECT-TYPE
SYNTAX INTEGER (1..8)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Temperature sensor number."
::= { wtWebioAn8SensorEntry 1 }
-- wtWebioAn8TempValue Table
wtWebioAn8TempValueTable OBJECT-TYPE
SYNTAX SEQUENCE OF WtWebioAn8TempValueEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"List of temperature values corresponding to the channel numbers."
::= { wtWebioAn8Temp 3 }
wtWebioAn8TempValueEntry OBJECT-TYPE
SYNTAX WtWebioAn8TempValueEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Temperatures of the sensors."
INDEX { wtWebioAn8SensorNo }
::= { wtWebioAn8TempValueTable 1 }
WtWebioAn8TempValueEntry ::= SEQUENCE{
wtWebioAn8TempValue OCTET STRING (SIZE (5))
}
wtWebioAn8TempValue OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (5))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Temperature value of the sensor, ASCII, 5 characters in length."
::= { wtWebioAn8TempValueEntry 1 }
-- wtWebioAn8BinaryTempValue Table
wtWebioAn8BinaryTempValueTable OBJECT-TYPE
SYNTAX SEQUENCE OF WtWebioAn8BinaryTempValueEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"List of binary temperature values corresponding to the channel numbers."
::= { wtWebioAn8Temp 4 }
wtWebioAn8BinaryTempValueEntry OBJECT-TYPE
SYNTAX WtWebioAn8BinaryTempValueEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Binary temperature values of the sensors."
INDEX { wtWebioAn8SensorNo }
::= { wtWebioAn8BinaryTempValueTable 1 }
WtWebioAn8BinaryTempValueEntry ::= SEQUENCE{
wtWebioAn8BinaryTempValue INTEGER
}
wtWebioAn8BinaryTempValue OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Binary temperature value of the sensor in 1/10 degrees Celsius,
signed number, 0x7FFF indicates an
invalid measured value."
::= { wtWebioAn8BinaryTempValueEntry 1 }
-- wtWebioAn8SessCntrl Group
--------------------------------
wtWebioAn8SessCntrlPassword OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Entering this password opens a session which is ended by writing a 1 to
wtWebioAn8SessCntrlLogout. When read this variable provides a string of
length zero."
::= { wtWebioAn8SessCntrl 1 }
wtWebioAn8SessCntrlConfigMode OBJECT-TYPE
SYNTAX INTEGER {
wtWebioAn8SessCntrl-NoSession(0),
wtWebioAn8SessCntrl-Session(1)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"When the device is in SNMP configuration mode, the value 1 is returned,
otherwise 0. If the read value is 0 even though the password was
written, the device is already in config mode and the variables can only
be read."
::= { wtWebioAn8SessCntrl 2 }
wtWebioAn8SessCntrlLogout OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"If the device is in configuration mode and the session was opened by
this SNMP Manager, writing a 1 to this variable will end the session and
all parameters are stored.
Writing a 2 discards all entries again.
When read this variable provides the value 0."
::= { wtWebioAn8SessCntrl 3 }
wtWebioAn8SessCntrlAdminPassword OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This password protects access to the variables with administrator rights.
It can only be changed by the administrator. If no password was assigned,
the valid password is public."
::= { wtWebioAn8SessCntrl 4 }
wtWebioAn8SessCntrlConfigPassword OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This password protects access to the variables with configurator rights. It can
be changed by the administrator and by the configurator. If no password was assigned,
the valid password is public. When read this variable provides a null-pointer."
::= { wtWebioAn8SessCntrl 5 }
-- wtWebioAn8Network Group
------------------------
wtWebioAn8IpAddress OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-write
STATUS mandatory
DESCRIPTION
"IP address of the Webio"
::= { wtWebioAn8Network 1 }
wtWebioAn8SubnetMask OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Subnet mask of the Webio"
::= { wtWebioAn8Network 2 }
wtWebioAn8Gateway OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Gateway of the Webio"
::= { wtWebioAn8Network 3 }
wtWebioAn8DnsServer1 OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"IP address of the 1st DNS server in ASCII"
::= { wtWebioAn8Network 4 }
wtWebioAn8DnsServer2 OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"IP address of the 2nd DNS server in ASCII"
::= { wtWebioAn8Network 5 }
wtWebioAn8AddConfig OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Additional configuration (1=ON):
Octet 1: unused
Octet 2: unused
Octet 3: unused
Octet 4:
Bit 0: BOOTP disable
"
::= { wtWebioAn8Network 6 }
-- wtWebioAn8Text Group
------------------------
wtWebioAn8DeviceName OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Name of the Webio, which is user definable."
::= { wtWebioAn8Text 1 }
wtWebioAn8DeviceText OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Description of the Webio, which is user definable."
::= { wtWebioAn8Text 2 }
wtWebioAn8DeviceLocation OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Description of the location of the Webio, which is user definable."
::= { wtWebioAn8Text 3 }
wtWebioAn8DeviceContact OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Contact address of the system operator of the Webio, which is user definable."
::= { wtWebioAn8Text 4 }
-- wtWebioAn8TimeZone Group
----------------------------
wtWebioAn8TzName OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Name of the time zone (winter time)."
::= { wtWebioAn8TimeZone 1 }
wtWebioAn8TzOffsetHrs OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Offset hours for the time zone (winter time) with respect to UTC."
::= { wtWebioAn8TimeZone 2 }
wtWebioAn8TzOffsetMin OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Offset minutes for the time zone (winter time) with respect to UTC."
::= { wtWebioAn8TimeZone 3 }
wtWebioAn8StTzName OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Name of the time zone (summer time)."
::= { wtWebioAn8TimeZone 4 }
wtWebioAn8StTzOffsetHrs OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Offset hours of the time zone (summer time) with respect to UTC."
::= { wtWebioAn8TimeZone 5 }
wtWebioAn8StTzOffsetMin OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Offset minutes of the time zone (summer time) with respect to UTC."
::= { wtWebioAn8TimeZone 6 }
wtWebioAn8StTzStartMonth OBJECT-TYPE
SYNTAX INTEGER {
wtWebioAn8StartMonth-January(1),
wtWebioAn8StartMonth-February(2),
wtWebioAn8StartMonth-March(3),
wtWebioAn8StartMonth-April(4),
wtWebioAn8StartMonth-May(5),
wtWebioAn8StartMonth-June(6),
wtWebioAn8StartMonth-July(7),
wtWebioAn8StartMonth-August(8),
wtWebioAn8StartMonth-September(9),
wtWebioAn8StartMonth-October(10),
wtWebioAn8StartMonth-November(11),
wtWebioAn8StartMonth-December(12)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Month in which the change is made from winter time to summer time."
::= { wtWebioAn8TimeZone 7 }
wtWebioAn8StTzStartMode OBJECT-TYPE
SYNTAX INTEGER {
wtWebioAn8StartMode-first(1),
wtWebioAn8StartMode-second(2),
wtWebioAn8StartMode-third(3),
wtWebioAn8StartMode-fourth(4),
wtWebioAn8StartMode-last(5)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Mode of the day of the week for which the change is made from winter time to summer time."
::= { wtWebioAn8TimeZone 8 }
wtWebioAn8StTzStartWday OBJECT-TYPE
SYNTAX INTEGER {
wtWebioAn8StartWday-Sunday(1),
wtWebioAn8StartWday-Monday(2),
wtWebioAn8StartWday-Tuesday(3),
wtWebioAn8StartWday-Thursday(4),
wtWebioAn8StartWday-Wednesday(5),
wtWebioAn8StartWday-Friday(6),
wtWebioAn8StartWday-Saturday(7)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Day of the week on which the change is made from winter time to summer time"
::= { wtWebioAn8TimeZone 9 }
wtWebioAn8StTzStartHrs OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Hour in which the time zone is changed from winter to summer time with
respect to UTC."
::= { wtWebioAn8TimeZone 10 }
wtWebioAn8StTzStartMin OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Minute in which the time zone is changed from winter to summer time with
respect to UTC."
::= { wtWebioAn8TimeZone 11 }
wtWebioAn8StTzStopMonth OBJECT-TYPE
SYNTAX INTEGER {
wtWebioAn8StopMonth-January(1),
wtWebioAn8StopMonth-February(2),
wtWebioAn8StopMonth-March(3),
wtWebioAn8StopMonth-April(4),
wtWebioAn8StopMonth-May(5),
wtWebioAn8StopMonth-June(6),
wtWebioAn8StopMonth-July(7),
wtWebioAn8StopMonth-August(8),
wtWebioAn8StopMonth-September(9),
wtWebioAn8StopMonth-October(10),
wtWebioAn8StopMonth-November(11),
wtWebioAn8StopMonth-December(12)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Month in which the change is made from summer time to winter time."
::= { wtWebioAn8TimeZone 12 }
wtWebioAn8StTzStopMode OBJECT-TYPE
SYNTAX INTEGER {
wtWebioAn8StopMode-first(1),
wtWebioAn8StopMode-second(2),
wtWebioAn8StopMode-third(3),
wtWebioAn8StopMode-fourth(4),
wtWebioAn8StopMode-last(5)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Mode of the week day on which the change is made from summer time to winter time."
::= { wtWebioAn8TimeZone 13 }
wtWebioAn8StTzStopWday OBJECT-TYPE
SYNTAX INTEGER {
wtWebioAn8StopWday-Sunday(1),
wtWebioAn8StopWday-Monday(2),
wtWebioAn8StopWday-Tuesday(3),
wtWebioAn8StopWday-Thursday(4),
wtWebioAn8StopWday-Wednesday(5),
wtWebioAn8StopWday-Friday(6),
wtWebioAn8StopWday-Saturday(7)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Day of the week on which the change is made from summer time to winter time."
::= { wtWebioAn8TimeZone 14 }
wtWebioAn8StTzStopHrs OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Hour at which the time zone is changed from summer to winter time with
respect to UTC."
::= { wtWebioAn8TimeZone 15 }
wtWebioAn8StTzStopMin OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Minute at which the time zone is changed from summer to winter time with
respect to UTC."
::= { wtWebioAn8TimeZone 16 }
-- wtWebioAn8TimeServer Group
----------------------------
wtWebioAn8TimeServer1 OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"IP address or name of the 1st time server in ASCII"
::= { wtWebioAn8TimeServer 1 }
wtWebioAn8TimeServer2 OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"IP address or name of the 2nd time server in ASCII"
::= { wtWebioAn8TimeServer 2 }
-- wtWebioAn8DeviceClock Group
----------------------------
wtWebioAn8ClockHrs OBJECT-TYPE
SYNTAX INTEGER (0..23)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Clock hours taking into account the time zone settings."
::= { wtWebioAn8DeviceClock 1 }
wtWebioAn8ClockMin OBJECT-TYPE
SYNTAX INTEGER (0..59)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Clock minutes taking into account the time zone settings."
::= { wtWebioAn8DeviceClock 2 }
wtWebioAn8ClockDay OBJECT-TYPE
SYNTAX INTEGER (1..31)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Date: Day of the month, taking into account the time zone settings."
::= { wtWebioAn8DeviceClock 3 }
wtWebioAn8ClockMonth OBJECT-TYPE
SYNTAX INTEGER {
wtWebioAn8ClockMonth-January(1),
wtWebioAn8ClockMonth-February(2),
wtWebioAn8ClockMonth-March(3),
wtWebioAn8ClockMonth-April(4),
wtWebioAn8ClockMonth-May(5),
wtWebioAn8ClockMonth-June(6),
wtWebioAn8ClockMonth-July(7),
wtWebioAn8ClockMonth-August(8),
wtWebioAn8ClockMonth-September(9),
wtWebioAn8ClockMonth-October(10),
wtWebioAn8ClockMonth-November(11),
wtWebioAn8ClockMonth-December(12)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Date: Month, taking into account the time zone settings."
::= { wtWebioAn8DeviceClock 4 }
wtWebioAn8ClockYear OBJECT-TYPE
SYNTAX INTEGER (0..65535)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Date: Year, taking into account the time zone settings."
::= { wtWebioAn8DeviceClock 5 }
-- wtWebioAn8MailAdmin Group
--------------------------------
wtWebioAn8MailAdName OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Device name for mail administration."
::= { wtWebioAn8MailAdmin 1 }
wtWebioAn8MailReply OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Reply address for the mail server."
::= { wtWebioAn8MailAdmin 2 }
wtWebioAn8MailServer OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Name or IP address of the mail server."
::= { wtWebioAn8MailAdmin 3 }
-- wtWebioAn8Alarm Group
----------------------------
wtWebioAn8AlarmCount OBJECT-TYPE
SYNTAX INTEGER (1..8)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Number of independent alarms."
::= { wtWebioAn8Alarm 1 }
-- Alarm Interface Table
wtWebioAn8AlarmIfTable OBJECT-TYPE
SYNTAX SEQUENCE OF WtWebioAn8AlarmIfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"List of alarm indices."
::= { wtWebioAn8Alarm 2 }
wtWebioAn8AlarmIfEntry OBJECT-TYPE
SYNTAX WtWebioAn8AlarmIfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Numbers of the alarms."
INDEX { wtWebioAn8AlarmNo }
::= { wtWebioAn8AlarmIfTable 1 }
WtWebioAn8AlarmIfEntry ::= SEQUENCE {
wtWebioAn8AlarmNo INTEGER (1..8)
}
wtWebioAn8AlarmNo OBJECT-TYPE
SYNTAX INTEGER (1..8)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Alarm number."
::= { wtWebioAn8AlarmIfEntry 1 }
-- Alarm Table
wtWebioAn8AlarmTable OBJECT-TYPE
SYNTAX SEQUENCE OF WtWebioAn8AlarmEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"List of settings depending on the alarm number."
::= { wtWebioAn8Alarm 3 }
wtWebioAn8AlarmEntry OBJECT-TYPE
SYNTAX WtWebioAn8AlarmEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Alarm parameters of the individual alarms."
INDEX { wtWebioAn8AlarmNo }
::= { wtWebioAn8AlarmTable 1 }
WtWebioAn8AlarmEntry ::= SEQUENCE {
wtWebioAn8AlarmTrigger OCTET STRING,
wtWebioAn8AlarmMin OCTET STRING,
wtWebioAn8AlarmMax OCTET STRING,
wtWebioAn8AlarmInterval OCTET STRING,
wtWebioAn8AlarmEnable OCTET STRING,
wtWebioAn8AlarmEMailAddr OCTET STRING,
wtWebioAn8AlarmMailSubject OCTET STRING,
wtWebioAn8AlarmMailText OCTET STRING,
wtWebioAn8AlarmManagerIP OCTET STRING,
wtWebioAn8AlarmTrapText OCTET STRING,
wtWebioAn8AlarmMailOptions OCTET STRING,
wtWebioAn8AlarmTcpIpAddr OCTET STRING,
wtWebioAn8AlarmTcpPort INTEGER,
wtWebioAn8AlarmTcpText OCTET STRING,
wtWebioAn8AlarmHystersis OCTET STRING,
wtWebioAn8AlarmClearMailSubject OCTET STRING,
wtWebioAn8AlarmClearMailText OCTET STRING,
wtWebioAn8AlarmClearTrapText OCTET STRING,
wtWebioAn8AlarmClearTcpText OCTET STRING
}
wtWebioAn8AlarmTrigger OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(4))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Binary coded trigger conditions:
Octet 1: unused
Octet 2: unused
Octet 3:
Bit 0: Timer
Bit 1: ColdStart
Bit 2: WarmStart
Octet 4:
Bit 0: Sensor 1
Bit 1: Sensor 2
Bit 2: Sensor 3
Bit 3: Sensor 4
Bit 4: Sensor 5
Bit 5: Sensor 6
Bit 6: Sensor 7
Bit 7: Sensor 8"
::= { wtWebioAn8AlarmEntry 1 }
wtWebioAn8AlarmMin OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Minimum temperature in degrees with maximum 2 decimal places."
::= { wtWebioAn8AlarmEntry 2 }
wtWebioAn8AlarmMax OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Maximum temperature in degrees with maximum 2 decimal places."
::= { wtWebioAn8AlarmEntry 3 }
wtWebioAn8AlarmInterval OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Send interval for alarm messages."
::= { wtWebioAn8AlarmEntry 4 }
wtWebioAn8AlarmEnable OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(4))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Binary coded alarm enable:
Octet 1: unused
Octet 2: unused
Octet 3: unused
Octet 4:
Bit 0: Mail Enable
Bit 1: SNMP Trap enable
Bit 2: TCP Client enable"
::= { wtWebioAn8AlarmEntry 5 }
wtWebioAn8AlarmEMailAddr OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"E-Mail address for sending the alarm mail to."
::= { wtWebioAn8AlarmEntry 6 }
wtWebioAn8AlarmMailSubject OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Subject line for alarm mail."
::= { wtWebioAn8AlarmEntry 7 }
wtWebioAn8AlarmMailText OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Alarm mail text: <Tn> provides the current temperature; n = 1..8.
<Z> provides the current time."
::= { wtWebioAn8AlarmEntry 8 }
wtWebioAn8AlarmManagerIP OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Name or IP address of the SNMP Manager which accepts the trap."
::= { wtWebioAn8AlarmEntry 9 }
wtWebioAn8AlarmTrapText OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This text is sent in the trap body."
::= { wtWebioAn8AlarmEntry 10 }
wtWebioAn8AlarmMailOptions OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(4))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Binary coded options:
Octet 1: unused
Octet 2: unused
Octet 3: unused
Octet 4:
Bit 0 : Attach Thermo.csv Enable
Bit 1-7: unused"
::= { wtWebioAn8AlarmEntry 11 }
wtWebioAn8AlarmTcpIpAddr OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Name or IP address of the TCP server which accepts the trap."
::= { wtWebioAn8AlarmEntry 12 }
wtWebioAn8AlarmTcpPort OBJECT-TYPE
SYNTAX INTEGER (1..65535)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Port number of the TCP server which accepts the trap."
::= { wtWebioAn8AlarmEntry 13 }
wtWebioAn8AlarmTcpText OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This text is sent in the TCP trap body."
::= { wtWebioAn8AlarmEntry 14 }
wtWebioAn8AlarmHysteresis OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Temperature changes of this size clears the alarm state (MAX-hyst, MIN+hyst.)
, in degrees with maximum 2 decimal places."
::= { wtWebioAn8AlarmEntry 15 }
wtWebioAn8AlarmClearMailSubject OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Subject line for alarm clear mail."
::= { wtWebioAn8AlarmEntry 16 }
wtWebioAn8AlarmClearMailText OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Alarm clear mail text: <Tn> provides the current temperature; n = 1..8.
<Z> provides the current time."
::= { wtWebioAn8AlarmEntry 17 }
wtWebioAn8AlarmClearTrapText OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This text is sent in the trap body."
::= { wtWebioAn8AlarmEntry 18 }
wtWebioAn8AlarmClearTcpText OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This text is sent in the TCP trap body."
::= { wtWebioAn8AlarmEntry 19 }
-- wtWebioAn8Datalogger Group
--------------------------------
wtWebioAn8LoggerTimebase OBJECT-TYPE
SYNTAX INTEGER {
wtWebioAn8Datalogger-1Min(1),
wtWebioAn8Datalogger-5Min(2),
wtWebioAn8Datalogger-15Min(3),
wtWebioAn8Datalogger-60Min(4)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Time base of the data logger"
::= { wtWebioAn8Datalogger 1 }
wtWebioAn8LoggerSensorSel OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(4))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Binary coded trigger conditions:
Octet 1: unused
Octet 2: unused
Octet 3: unused
Octet 4:
Bit 0: Sensor 1
Bit 1: Sensor 2
Bit 2: Sensor 3
Bit 3: Sensor 4
Bit 4: Sensor 5
Bit 5: Sensor 6
Bit 6: Sensor 7
Bit 7: Sensor 8"
::= { wtWebioAn8Datalogger 2 }
-- wtWebioAn8Protocol Group
----------------------------
wtWebioAn8PrtclUdpPort OBJECT-TYPE
SYNTAX INTEGER (1..65535)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Udp port to which the Udp queries GET Single can be sent"
::= { wtWebioAn8PrtclUDP 1 }
wtWebioAn8PrtclSnmpCommunityStringRead OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Community string read only"
::= { wtWebioAn8PrtclSNMP 1 }
wtWebioAn8PrtclSnmpCommunityStringReadWrite OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Community string read / write"
::= { wtWebioAn8PrtclSNMP 2 }
wtWebioAn8SystemTrapManagerIP OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Name or IP address of the TCP server which accepts the system trap."
::= { wtWebioAn8PrtclSNMP 3 }
wtWebioAn8SystemTrapEnable OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(4))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Binary coded trigger conditions:
Octet 1: unused
Octet 2: unused
Octet 3: unused
Octet 4:
Bit 0: ColdStart
Bit 1: WarmStart
Bit 2-7: unused"
::= { wtWebioAn8PrtclSNMP 4 }
wtWebioAn8PrtclHttpPort OBJECT-TYPE
SYNTAX INTEGER (1..65535)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"HTTP port to which the HTTP queries GET Single can be sent"
::= { wtWebioAn8PrtclHttp 1 }
-- wtWebioAn8Enable Group
----------------------------
wtWebioAn8Enables OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(4))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Binary coded trigger conditions:
Octet 1: unused
Octet 2: unused
Octet 3: unused
Octet 4:
Bit 0: Update enable
Bit 1: Mail enable
Bit 2: Snmp enable
Bit 3: UDP enable
Bit 4: Get Singel Header enable
Bit 5: Apply Timezone
Bit 6: Apply Summertime
Bit 7: Apply TimeServer"
::= { wtWebioAn8Enable 1 }
-- wtWebioAn8Startup Group
----------------------------
wtWebioAn8StartupSite OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(4))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Binary coded start page:
Octet 1: unused
Octet 2: unused
Octet 3: unused
Octet 4:
Bit 1: Index.htm
Bit 2: Home.htm
Bit 3: User.htm
Only one page may be selected at a time."
::= { wtWebioAn8Startup 1 }
-- wtWebioAn8Ports Group
----------------------------
-- Table
wtWebioAn8PortTable OBJECT-TYPE
SYNTAX SEQUENCE OF WtWebioAn8PortEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"List of settings depending on the sensor number."
::= { wtWebioAn8Ports 1 }
wtWebioAn8PortEntry OBJECT-TYPE
SYNTAX WtWebioAn8PortEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Sensor parameters for the individual sensors."
INDEX { wtWebioAn8SensorNo }
::= { wtWebioAn8PortTable 1 }
WtWebioAn8PortEntry ::= SEQUENCE {
wtWebioAn8PortName OCTET STRING,
wtWebioAn8PortText OCTET STRING,
wtWebioAn8PortOffset1 OCTET STRING,
wtWebioAn8PortTemperature1 OCTET STRING,
wtWebioAn8PortOffset2 OCTET STRING,
wtWebioAn8PortTemperature2 OCTET STRING,
wtWebioAn8PortComment OCTET STRING
}
wtWebioAn8PortName OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Name of the sensor."
::= { wtWebioAn8PortEntry 1 }
wtWebioAn8PortText OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Description of the sensor."
::= { wtWebioAn8PortEntry 2 }
wtWebioAn8PortOffset1 OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Offset calibration: Offset in degrees with maximum 2 decimal places at temperature 1."
::= { wtWebioAn8PortEntry 3 }
wtWebioAn8PortTemperature1 OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Offset calibration: Reference temperature 1 in degrees with maximum 2 decimal places."
::= { wtWebioAn8PortEntry 4 }
wtWebioAn8PortOffset2 OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Offset calibration: Offset in degrees with maximum 2 decimal places at temperature 2."
::= { wtWebioAn8PortEntry 5 }
wtWebioAn8PortTemperature2 OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Offset calibration: Reference temperature 1 in degrees with maximum 2 decimal places."
::= { wtWebioAn8PortEntry 6 }
wtWebioAn8PortComment OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Offset calibration: informations of date, name of operator, reference devices."
::= { wtWebioAn8PortEntry 7 }
-- wtWebioAn8Manufact Group
----------------------------
wtWebioAn8MfName OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Manufacturer company name"
::= { wtWebioAn8Manufact 1 }
wtWebioAn8MfAddr OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Manufacturer address."
::= { wtWebioAn8Manufact 2 }
wtWebioAn8MfHotline OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Manufacturer hotline."
::= { wtWebioAn8Manufact 3 }
wtWebioAn8MfInternet OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Manufacturer Internet address."
::= { wtWebioAn8Manufact 4 }
wtWebioAn8MfDeviceTyp OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Manufacturer device name (model number)."
::= { wtWebioAn8Manufact 5 }
wtWebioAn8MfOrderNo OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Manufacturer part number."
::= { wtWebioAn8Manufact 6 }
-- TRAP DEFINITIONS
-- These SNMP traps are sent when the alarm trigger conditions apply
wtWebioAn8Alert1 TRAP-TYPE
ENTERPRISE wtWebioAn8
VARIABLES { wtWebioAn8AlarmTrapText }
DESCRIPTION
"This SNMP trap is generated when Alarm 1 was triggered,
SNMP trap enable is set and
SNMP is enabled."
-- NMS trap annotation
--#TYPE "WebThermometer Alarm 1"
--#SUMMARY "Alarm 1: %s"
--#ARGUMENTS {0}
--#SEVERITY INFORMATIONAL
--#TIMEINDEX 99
--#STATE OPERATIONAL
::= 11
wtWebioAn8Alert2 TRAP-TYPE
ENTERPRISE wtWebioAn8
VARIABLES { wtWebioAn8AlarmTrapText }
DESCRIPTION
"This SNMP trap is generated when Alarm 2 was triggered,
SNMP trap enable is set and
SNMP is enabled."
-- NMS trap annotation
--#TYPE "WebThermometer Alarm 2"
--#SUMMARY "Alarm 2: %s"
--#ARGUMENTS {0}
--#SEVERITY INFORMATIONAL
--#TIMEINDEX 99
--#STATE OPERATIONAL
::= 12
wtWebioAn8Alert3 TRAP-TYPE
ENTERPRISE wtWebioAn8
VARIABLES { wtWebioAn8AlarmTrapText }
DESCRIPTION
"This SNMP trap is generated when Alarm 3 was triggered,
SNMP trap enable is set and
SNMP is enabled."
-- NMS trap annotation
--#TYPE "WebThermometer Alarm 3"
--#SUMMARY "Alarm 3: %s"
--#ARGUMENTS {0}
--#SEVERITY INFORMATIONAL
--#TIMEINDEX 99
--#STATE OPERATIONAL
::= 13
wtWebioAn8Alert4 TRAP-TYPE
ENTERPRISE wtWebioAn8
VARIABLES { wtWebioAn8AlarmTrapText }
DESCRIPTION
"This SNMP trap is generated when Alarm 4 was triggered,
SNMP trap enable is set and
SNMP is enabled."
-- NMS trap annotation
--#TYPE "WebThermometer Alarm 4"
--#SUMMARY "Alarm 4: %s"
--#ARGUMENTS {0}
--#SEVERITY INFORMATIONAL
--#TIMEINDEX 99
--#STATE OPERATIONAL
::= 14
wtWebioAn8Alert5 TRAP-TYPE
ENTERPRISE wtWebioAn8
VARIABLES { wtWebioAn8AlarmTrapText }
DESCRIPTION
"This SNMP trap is generated when Alarm 5 was triggered,
SNMP trap enable is set and
SNMP is enabled."
-- NMS trap annotation
--#TYPE "WebThermometer Alarm 5"
--#SUMMARY "Alarm 5: %s"
--#ARGUMENTS {0}
--#SEVERITY INFORMATIONAL
--#TIMEINDEX 99
--#STATE OPERATIONAL
::= 15
wtWebioAn8Alert6 TRAP-TYPE
ENTERPRISE wtWebioAn8
VARIABLES { wtWebioAn8AlarmTrapText }
DESCRIPTION
"This SNMP trap is generated when Alarm 6 was triggered,
SNMP trap enable is set and
SNMP is enabled."
-- NMS trap annotation
--#TYPE "WebThermometer Alarm 6"
--#SUMMARY "Alarm 6: %s"
--#ARGUMENTS {0}
--#SEVERITY INFORMATIONAL
--#TIMEINDEX 99
--#STATE OPERATIONAL
::= 16
wtWebioAn8Alert7 TRAP-TYPE
ENTERPRISE wtWebioAn8
VARIABLES { wtWebioAn8AlarmTrapText }
DESCRIPTION
"This SNMP trap is generated when Alarm 7 was triggered,
SNMP trap enable is set and
SNMP is enabled."
-- NMS trap annotation
--#TYPE "WebThermometer Alarm 7"
--#SUMMARY "Alarm 7: %s"
--#ARGUMENTS {0}
--#SEVERITY INFORMATIONAL
--#TIMEINDEX 99
--#STATE OPERATIONAL
::= 17
wtWebioAn8Alert8 TRAP-TYPE
ENTERPRISE wtWebioAn8
VARIABLES { wtWebioAn8AlarmTrapText }
DESCRIPTION
"This SNMP trap is generated when Alarm 8 was triggered,
SNMP trap enable is set and
SNMP is enabled."
-- NMS trap annotation
--#TYPE "WebThermometer Alarm 8"
--#SUMMARY "Alarm 8: %s"
--#ARGUMENTS {0}
--#SEVERITY INFORMATIONAL
--#TIMEINDEX 99
--#STATE OPERATIONAL
::= 18
wtWebioAn8Alert9 TRAP-TYPE
ENTERPRISE wtWebioAn8
VARIABLES { wtWebioAn8AlarmClearTrapText }
DESCRIPTION
"This SNMP trap is generated when Alarm 1 was cleared,
SNMP trap enable is set and
SNMP is enabled."
-- NMS trap annotation
--#TYPE "WebThermometer Release Alarm 1"
--#SUMMARY "Alarm 1: %s"
--#ARGUMENTS {0}
--#SEVERITY INFORMATIONAL
--#TIMEINDEX 99
--#STATE OPERATIONAL
::= 71
wtWebioAn8Alert10 TRAP-TYPE
ENTERPRISE wtWebioAn8
VARIABLES { wtWebioAn8AlarmClearTrapText }
DESCRIPTION
"This SNMP trap is generated when Alarm 2 was cleared,
SNMP trap enable is set and
SNMP is enabled."
-- NMS trap annotation
--#TYPE "WebThermometer Release Alarm 2"
--#SUMMARY "Alarm 2: %s"
--#ARGUMENTS {0}
--#SEVERITY INFORMATIONAL
--#TIMEINDEX 99
--#STATE OPERATIONAL
::= 72
wtWebioAn8Alert11 TRAP-TYPE
ENTERPRISE wtWebioAn8
VARIABLES { wtWebioAn8AlarmClearTrapText }
DESCRIPTION
"This SNMP trap is generated when Alarm 3 was cleared,
SNMP trap enable is set and
SNMP is enabled."
-- NMS trap annotation
--#TYPE "WebThermometer Release Alarm 3"
--#SUMMARY "Alarm 3: %s"
--#ARGUMENTS {0}
--#SEVERITY INFORMATIONAL
--#TIMEINDEX 99
--#STATE OPERATIONAL
::= 73
wtWebioAn8Alert12 TRAP-TYPE
ENTERPRISE wtWebioAn8
VARIABLES { wtWebioAn8AlarmClearTrapText }
DESCRIPTION
"This SNMP trap is generated when Alarm 4 was cleared,
SNMP trap enable is set and
SNMP is enabled."
-- NMS trap annotation
--#TYPE "WebThermometer Release Alarm 4"
--#SUMMARY "Alarm 4: %s"
--#ARGUMENTS {0}
--#SEVERITY INFORMATIONAL
--#TIMEINDEX 99
--#STATE OPERATIONAL
::= 74
wtWebioAn8Alert13 TRAP-TYPE
ENTERPRISE wtWebioAn8
VARIABLES { wtWebioAn8AlarmClearTrapText }
DESCRIPTION
"This SNMP trap is generated when Alarm 5 was cleared,
SNMP trap enable is set and
SNMP is enabled."
-- NMS trap annotation
--#TYPE "WebThermometer Release Alarm 5"
--#SUMMARY "Alarm 5: %s"
--#ARGUMENTS {0}
--#SEVERITY INFORMATIONAL
--#TIMEINDEX 99
--#STATE OPERATIONAL
::= 75
wtWebioAn8Alert14 TRAP-TYPE
ENTERPRISE wtWebioAn8
VARIABLES { wtWebioAn8AlarmClearTrapText }
DESCRIPTION
"This SNMP trap is generated when Alarm 6 was cleared,
SNMP trap enable is set and
SNMP is enabled."
-- NMS trap annotation
--#TYPE "WebThermometer Release Alarm 6"
--#SUMMARY "Alarm 6: %s"
--#ARGUMENTS {0}
--#SEVERITY INFORMATIONAL
--#TIMEINDEX 99
--#STATE OPERATIONAL
::= 76
wtWebioAn8Alert15 TRAP-TYPE
ENTERPRISE wtWebioAn8
VARIABLES { wtWebioAn8AlarmClearTrapText }
DESCRIPTION
"This SNMP trap is generated when Alarm 7 was cleared,
SNMP trap enable is set and
SNMP is enabled."
-- NMS trap annotation
--#TYPE "WebThermometer Release Alarm 7"
--#SUMMARY "Alarm 7: %s"
--#ARGUMENTS {0}
--#SEVERITY INFORMATIONAL
--#TIMEINDEX 99
--#STATE OPERATIONAL
::= 77
wtWebioAn8Alert16 TRAP-TYPE
ENTERPRISE wtWebioAn8
VARIABLES { wtWebioAn8AlarmClearTrapText }
DESCRIPTION
"This SNMP trap is generated when Alarm 8 was cleared,
SNMP trap enable is set and
SNMP is enabled."
-- NMS trap annotation
--#TYPE "WebThermometer Release Alarm 8"
--#SUMMARY "Alarm 8: %s"
--#ARGUMENTS {0}
--#SEVERITY INFORMATIONAL
--#TIMEINDEX 99
--#STATE OPERATIONAL
::= 78
--------------------------------------------------------------------------------
--------------------------------------------------------------------------------
--------------------------------------------------------------------------------
-- wtWebioAn2Temp Group
------------------------
wtWebioAn2Sensors OBJECT-TYPE
SYNTAX INTEGER (1..2)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Number of temperature sensors"
::= { wtWebioAn2Temp 1 }
-- Interface Table
wtWebioAn2SensorTable OBJECT-TYPE
SYNTAX SEQUENCE OF WtWebioAn2SensorEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"List of Sensors."
::= { wtWebioAn2Temp 2 }
wtWebioAn2SensorEntry OBJECT-TYPE
SYNTAX WtWebioAn2SensorEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Temperature sensor numbers."
INDEX { wtWebioAn2SensorNo }
::= { wtWebioAn2SensorTable 1 }
WtWebioAn2SensorEntry ::= SEQUENCE {
wtWebioAn2SensorNo INTEGER (1..2)
}
wtWebioAn2SensorNo OBJECT-TYPE
SYNTAX INTEGER (1..2)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Temperature sensor number."
::= { wtWebioAn2SensorEntry 1 }
-- wtWebioAn2TempValue Table
wtWebioAn2TempValueTable OBJECT-TYPE
SYNTAX SEQUENCE OF WtWebioAn2TempValueEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"List of temperature values corresponding to the channel numbers."
::= { wtWebioAn2Temp 3 }
wtWebioAn2TempValueEntry OBJECT-TYPE
SYNTAX WtWebioAn2TempValueEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Temperatures of the sensors."
INDEX { wtWebioAn2SensorNo }
::= { wtWebioAn2TempValueTable 1 }
WtWebioAn2TempValueEntry ::= SEQUENCE{
wtWebioAn2TempValue OCTET STRING (SIZE (5))
}
wtWebioAn2TempValue OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (5))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Temperature value of the sensor, ASCII, 5 characters in length."
::= { wtWebioAn2TempValueEntry 1 }
-- wtWebioAn2BinaryTempValue Table
wtWebioAn2BinaryTempValueTable OBJECT-TYPE
SYNTAX SEQUENCE OF WtWebioAn2BinaryTempValueEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"List of binary temperature values corresponding to the channel numbers."
::= { wtWebioAn2Temp 4 }
wtWebioAn2BinaryTempValueEntry OBJECT-TYPE
SYNTAX WtWebioAn2BinaryTempValueEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Binary temperature values of the sensors."
INDEX { wtWebioAn2SensorNo }
::= { wtWebioAn2BinaryTempValueTable 1 }
WtWebioAn2BinaryTempValueEntry ::= SEQUENCE{
wtWebioAn2BinaryTempValue INTEGER
}
wtWebioAn2BinaryTempValue OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Binary temperature value of the sensor in 1/10 degrees Celsius,
signed number, 0x7FFF indicates an
invalid measured value."
::= { wtWebioAn2BinaryTempValueEntry 1 }
-- wtWebioAn2SessCntrl Group
----------------------------
wtWebioAn2SessCntrlPassword OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Entering this password opens a session which is ended by writing a 1 to
wtWebioAn2SessCntrlLogout. When read this variable provides a string of
length zero."
::= { wtWebioAn2SessCntrl 1 }
wtWebioAn2SessCntrlConfigMode OBJECT-TYPE
SYNTAX INTEGER {
wtWebioAn2SessCntrl-NoSession(0),
wtWebioAn2SessCntrl-Session(1)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"When the device is in SNMP configuration mode, the value 1 is
returned, otherwise 0. If the read value is 0 even though the
password was written, the device is already in config mode and
the variables can only be read."
::= { wtWebioAn2SessCntrl 2 }
wtWebioAn2SessCntrlLogout OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"If the device is in configuration mode and the session was opened by
this SNMP Manager, writing a 1 to this variable will end the session
and all parameters are stored.
Writing a 2 discards all entries again.
When read this variable provides the value 0."
::= { wtWebioAn2SessCntrl 3 }
wtWebioAn2SessCntrlAdminPassword OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This password protects access to the variables with administrator rights.
It can only be changed by the administrator. If no password was assigned,
the valid password is public."
::= { wtWebioAn2SessCntrl 4 }
wtWebioAn2SessCntrlConfigPassword OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This password protects access to the variables with configurator rights. It can
be changed by the administrator and by the configurator. If no password was assigned,
the valid password is public. When read this variable provides a null-pointer."
::= { wtWebioAn2SessCntrl 5 }
-- wtWebioAn2Network Group
------------------------
wtWebioAn2IpAddress OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-write
STATUS mandatory
DESCRIPTION
"IP address of the Webio"
::= { wtWebioAn2Network 1 }
wtWebioAn2SubnetMask OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-write
STATUS mandatory
DESCRIPTION
"ubnet mask of the Webio"
::= { wtWebioAn2Network 2 }
wtWebioAn2Gateway OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Gateway of the Webio"
::= { wtWebioAn2Network 3 }
wtWebioAn2DnsServer1 OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"IP address of the 1st DNS server in ASCII"
::= { wtWebioAn2Network 4 }
wtWebioAn2DnsServer2 OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"IP address of the 2nd DNS server in ASCII"
::= { wtWebioAn2Network 5 }
wtWebioAn2AddConfig OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Additional configuration (1=ON):
Octet 1: unused
Octet 2: unused
Octet 3: unused
Octet 4:
Bit 0: BOOTP disable
"
::= { wtWebioAn2Network 6 }
-- wtWebioAn2Text Group
------------------------
wtWebioAn2DeviceName OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Name of the Webio, which is user definable."
::= { wtWebioAn2Text 1 }
wtWebioAn2DeviceText OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Description of the Webio, which is user definable."
::= { wtWebioAn2Text 2 }
wtWebioAn2DeviceLocation OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Description of the location of the Webio, which is user definable."
::= { wtWebioAn2Text 3 }
wtWebioAn2DeviceContact OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Contact address of the system operator of the Webio, which is user definable."
::= { wtWebioAn2Text 4 }
-- wtWebioAn2TimeZone Group
----------------------------
wtWebioAn2TzName OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Name of the time zone (winter time)."
::= { wtWebioAn2TimeZone 1 }
wtWebioAn2TzOffsetHrs OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Offset hours for the time zone (winter time) with respect to UTC."
::= { wtWebioAn2TimeZone 2 }
wtWebioAn2TzOffsetMin OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Offset minutes for the time zone (winter time) with respect to UTC."
::= { wtWebioAn2TimeZone 3 }
wtWebioAn2StTzName OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Name of the time zone (summer time)."
::= { wtWebioAn2TimeZone 4 }
wtWebioAn2StTzOffsetHrs OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Offset hours of the time zone (summer time) with respect to UTC."
::= { wtWebioAn2TimeZone 5 }
wtWebioAn2StTzOffsetMin OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Offset minutes of the time zone (summer time) with respect to UTC."
::= { wtWebioAn2TimeZone 6 }
wtWebioAn2StTzStartMonth OBJECT-TYPE
SYNTAX INTEGER {
wtWebioAn2StartMonth-January(1),
wtWebioAn2StartMonth-February(2),
wtWebioAn2StartMonth-March(3),
wtWebioAn2StartMonth-April(4),
wtWebioAn2StartMonth-May(5),
wtWebioAn2StartMonth-June(6),
wtWebioAn2StartMonth-July(7),
wtWebioAn2StartMonth-August(8),
wtWebioAn2StartMonth-September(9),
wtWebioAn2StartMonth-October(10),
wtWebioAn2StartMonth-November(11),
wtWebioAn2StartMonth-December(12)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Month in which the change is made from winter time to summer time."
::= { wtWebioAn2TimeZone 7 }
wtWebioAn2StTzStartMode OBJECT-TYPE
SYNTAX INTEGER {
wtWebioAn2StartMode-first(1),
wtWebioAn2StartMode-second(2),
wtWebioAn2StartMode-third(3),
wtWebioAn2StartMode-fourth(4),
wtWebioAn2StartMode-last(5)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Mode of the day of the week for which the change is made from winter time to summer time."
::= { wtWebioAn2TimeZone 8 }
wtWebioAn2StTzStartWday OBJECT-TYPE
SYNTAX INTEGER {
wtWebioAn2StartWday-Sunday(1),
wtWebioAn2StartWday-Monday(2),
wtWebioAn2StartWday-Tuesday(3),
wtWebioAn2StartWday-Thursday(4),
wtWebioAn2StartWday-Wednesday(5),
wtWebioAn2StartWday-Friday(6),
wtWebioAn2StartWday-Saturday(7)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Day of the week on which the change is made from winter time to summer time"
::= { wtWebioAn2TimeZone 9 }
wtWebioAn2StTzStartHrs OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Hour in which the time zone is changed from winter to summer time with
respect to UTC."
::= { wtWebioAn2TimeZone 10 }
wtWebioAn2StTzStartMin OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Minute in which the time zone is changed from winter to summer time with
respect to UTC."
::= { wtWebioAn2TimeZone 11 }
wtWebioAn2StTzStopMonth OBJECT-TYPE
SYNTAX INTEGER {
wtWebioAn2StopMonth-January(1),
wtWebioAn2StopMonth-February(2),
wtWebioAn2StopMonth-March(3),
wtWebioAn2StopMonth-April(4),
wtWebioAn2StopMonth-May(5),
wtWebioAn2StopMonth-June(6),
wtWebioAn2StopMonth-July(7),
wtWebioAn2StopMonth-August(8),
wtWebioAn2StopMonth-September(9),
wtWebioAn2StopMonth-October(10),
wtWebioAn2StopMonth-November(11),
wtWebioAn2StopMonth-December(12)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Month in which the change is made from summer time to winter time."
::= { wtWebioAn2TimeZone 12 }
wtWebioAn2StTzStopMode OBJECT-TYPE
SYNTAX INTEGER {
wtWebioAn2StopMode-first(1),
wtWebioAn2StopMode-second(2),
wtWebioAn2StopMode-third(3),
wtWebioAn2StopMode-fourth(4),
wtWebioAn2StopMode-last(5)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Mode of the week day on which the change is made from summer time to winter time."
::= { wtWebioAn2TimeZone 13 }
wtWebioAn2StTzStopWday OBJECT-TYPE
SYNTAX INTEGER {
wtWebioAn2StopWday-Sunday(1),
wtWebioAn2StopWday-Monday(2),
wtWebioAn2StopWday-Tuesday(3),
wtWebioAn2StopWday-Thursday(4),
wtWebioAn2StopWday-Wednesday(5),
wtWebioAn2StopWday-Friday(6),
wtWebioAn2StopWday-Saturday(7)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Day of the week on which the change is made from summer time to winter time."
::= { wtWebioAn2TimeZone 14 }
wtWebioAn2StTzStopHrs OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Hour at which the time zone is changed from summer to winter time with
respect to UTC."
::= { wtWebioAn2TimeZone 15 }
wtWebioAn2StTzStopMin OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Minute at which the time zone is changed from summer to winter time with
respect to UTC."
::= { wtWebioAn2TimeZone 16 }
-- wtWebioAn2TimeServer Group
----------------------------
wtWebioAn2TimeServer1 OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"IP address or name of the 1st time server in ASCII"
::= { wtWebioAn2TimeServer 1 }
wtWebioAn2TimeServer2 OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"IP address or name of the 2nd time server in ASCII"
::= { wtWebioAn2TimeServer 2 }
-- wtWebioAn2DeviceClock Group
----------------------------
wtWebioAn2ClockHrs OBJECT-TYPE
SYNTAX INTEGER (0..23)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Clock hours taking into account the time zone settings."
::= { wtWebioAn2DeviceClock 1 }
wtWebioAn2ClockMin OBJECT-TYPE
SYNTAX INTEGER (0..59)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Clock minutes taking into account the time zone settings."
::= { wtWebioAn2DeviceClock 2 }
wtWebioAn2ClockDay OBJECT-TYPE
SYNTAX INTEGER (1..31)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Date: Day of the month, taking into account the time zone settings."
::= { wtWebioAn2DeviceClock 3 }
wtWebioAn2ClockMonth OBJECT-TYPE
SYNTAX INTEGER {
wtWebioAn2ClockMonth-January(1),
wtWebioAn2ClockMonth-February(2),
wtWebioAn2ClockMonth-March(3),
wtWebioAn2ClockMonth-April(4),
wtWebioAn2ClockMonth-May(5),
wtWebioAn2ClockMonth-June(6),
wtWebioAn2ClockMonth-July(7),
wtWebioAn2ClockMonth-August(8),
wtWebioAn2ClockMonth-September(9),
wtWebioAn2ClockMonth-October(10),
wtWebioAn2ClockMonth-November(11),
wtWebioAn2ClockMonth-December(12)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Date: Month, taking into account the time zone settings."
::= { wtWebioAn2DeviceClock 4 }
wtWebioAn2ClockYear OBJECT-TYPE
SYNTAX INTEGER (0..65535)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Date: Year, taking into account the time zone settings."
::= { wtWebioAn2DeviceClock 5 }
-- wtWebioAn2MailAdmin Group
----------------------------
wtWebioAn2MailAdName OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Device name for mail administration."
::= { wtWebioAn2MailAdmin 1 }
wtWebioAn2MailReply OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Reply address for the mail server."
::= { wtWebioAn2MailAdmin 2 }
wtWebioAn2MailServer OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Name or IP address of the mail server."
::= { wtWebioAn2MailAdmin 3 }
-- wtWebioAn2Alarm Group
----------------------------
wtWebioAn2AlarmCount OBJECT-TYPE
SYNTAX INTEGER (1..8)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Number of independent alarms."
::= { wtWebioAn2Alarm 1 }
-- Alarm Interface Table
wtWebioAn2AlarmIfTable OBJECT-TYPE
SYNTAX SEQUENCE OF WtWebioAn2AlarmIfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"List of alarm indices."
::= { wtWebioAn2Alarm 2 }
wtWebioAn2AlarmIfEntry OBJECT-TYPE
SYNTAX WtWebioAn2AlarmIfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Numbers of the alarms."
INDEX { wtWebioAn2AlarmNo }
::= { wtWebioAn2AlarmIfTable 1 }
WtWebioAn2AlarmIfEntry ::= SEQUENCE {
wtWebioAn2AlarmNo INTEGER (1..8)
}
wtWebioAn2AlarmNo OBJECT-TYPE
SYNTAX INTEGER (1..8)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Alarm number."
::= { wtWebioAn2AlarmIfEntry 1 }
-- Alarm Table
wtWebioAn2AlarmTable OBJECT-TYPE
SYNTAX SEQUENCE OF WtWebioAn2AlarmEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"List of settings depending on the alarm number."
::= { wtWebioAn2Alarm 3 }
wtWebioAn2AlarmEntry OBJECT-TYPE
SYNTAX WtWebioAn2AlarmEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Alarm parameters of the individual alarms."
INDEX { wtWebioAn2AlarmNo }
::= { wtWebioAn2AlarmTable 1 }
WtWebioAn2AlarmEntry ::= SEQUENCE {
wtWebioAn2AlarmTrigger OCTET STRING,
wtWebioAn2AlarmMin OCTET STRING,
wtWebioAn2AlarmMax OCTET STRING,
wtWebioAn2AlarmInterval OCTET STRING,
wtWebioAn2AlarmEnable OCTET STRING,
wtWebioAn2AlarmEMailAddr OCTET STRING,
wtWebioAn2AlarmMailSubject OCTET STRING,
wtWebioAn2AlarmMailText OCTET STRING,
wtWebioAn2AlarmManagerIP OCTET STRING,
wtWebioAn2AlarmTrapText OCTET STRING,
wtWebioAn2AlarmMailOptions OCTET STRING,
wtWebioAn2AlarmTcpIpAddr OCTET STRING,
wtWebioAn2AlarmTcpPort INTEGER,
wtWebioAn2AlarmTcpText OCTET STRING,
wtWebioAn2AlarmHystersis OCTET STRING,
wtWebioAn2AlarmClearMailSubject OCTET STRING,
wtWebioAn2AlarmClearMailText OCTET STRING,
wtWebioAn2AlarmClearTrapText OCTET STRING,
wtWebioAn2AlarmClearTcpText OCTET STRING
}
wtWebioAn2AlarmTrigger OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(4))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Binary coded trigger conditions:
Octet 1: unused
Octet 2: unused
Octet 3: unused
Octet 4:
Bit 0: Sensor 1
Bit 1: Sensor 2
Bit 2: Timer
Bit 1: ColdStart
Bit 2: WarmStart"
::= { wtWebioAn2AlarmEntry 1 }
wtWebioAn2AlarmMin OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Minimum temperature in degrees with maximum 2 decimal places."
::= { wtWebioAn2AlarmEntry 2 }
wtWebioAn2AlarmMax OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Maximum temperature in degrees with maximum 2 decimal places."
::= { wtWebioAn2AlarmEntry 3 }
wtWebioAn2AlarmInterval OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Send interval for alarm messages."
::= { wtWebioAn2AlarmEntry 4 }
wtWebioAn2AlarmEnable OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(4))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Binary coded alarm enable:
Octet 1: unused
Octet 2: unused
Octet 3: unused
Octet 4:
Bit 0: Mail Enable
Bit 1: SNMP Trap enable
Bit 2: TCP Client enable"
::= { wtWebioAn2AlarmEntry 5 }
wtWebioAn2AlarmEMailAddr OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"E-Mail address for sending the alarm mail to."
::= { wtWebioAn2AlarmEntry 6 }
wtWebioAn2AlarmMailSubject OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Subject line for alarm mail."
::= { wtWebioAn2AlarmEntry 7 }
wtWebioAn2AlarmMailText OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Alarm mail text: <Tn> provides the current temperature; n = 1..2.
<Z> provides the current time."
::= { wtWebioAn2AlarmEntry 8 }
wtWebioAn2AlarmManagerIP OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Name or IP address of the SNMP Manager which accepts the trap."
::= { wtWebioAn2AlarmEntry 9 }
wtWebioAn2AlarmTrapText OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This text is sent in the trap body."
::= { wtWebioAn2AlarmEntry 10 }
wtWebioAn2AlarmMailOptions OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(4))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Binary coded options:
Octet 1: unused
Octet 2: unused
Octet 3: unused
Octet 4:
Bit 0 : Attach Thermo.csv Enable
Bit 1-7: unused"
::= { wtWebioAn2AlarmEntry 11 }
wtWebioAn2AlarmTcpIpAddr OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Name or IP address of the TCP server which accepts the trap."
::= { wtWebioAn2AlarmEntry 12 }
wtWebioAn2AlarmTcpPort OBJECT-TYPE
SYNTAX INTEGER (1..65535)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Port number of the TCP server which accepts the trap."
::= { wtWebioAn2AlarmEntry 13 }
wtWebioAn2AlarmTcpText OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This text is sent in the TCP trap body."
::= { wtWebioAn2AlarmEntry 14 }
wtWebioAn2AlarmHysteresis OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Temperature changes of this size clears the alarm state (MAX-hyst, MIN+hyst.)
, in degrees with maximum 2 decimal places."
::= { wtWebioAn2AlarmEntry 15 }
wtWebioAn2AlarmClearMailSubject OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Subject line for alarm clear mail."
::= { wtWebioAn2AlarmEntry 16 }
wtWebioAn2AlarmClearMailText OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Alarm clear mail text: <Tn> provides the current temperature; n = 1..8.
<Z> provides the current time."
::= { wtWebioAn2AlarmEntry 17 }
wtWebioAn2AlarmClearTrapText OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This text is sent in the trap body."
::= { wtWebioAn2AlarmEntry 18 }
wtWebioAn2AlarmClearTcpText OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This text is sent in the TCP trap body."
::= { wtWebioAn2AlarmEntry 19 }
-- wtWebioAn2Datalogger Group
--------------------------------
wtWebioAn2LoggerTimebase OBJECT-TYPE
SYNTAX INTEGER {
wtWebioAn2Datalogger-1Min(1),
wtWebioAn2Datalogger-5Min(2),
wtWebioAn2Datalogger-15Min(3),
wtWebioAn2Datalogger-60Min(4)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Time base of the data logger"
::= { wtWebioAn2Datalogger 1 }
wtWebioAn2LoggerSensorSel OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(4))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Binary coded trigger conditions:
Octet 1: unused
Octet 2: unused
Octet 3: unused
Octet 4:
Bit 0: Sensor 1
Bit 1: Sensor 2"
::= { wtWebioAn2Datalogger 2 }
-- wtWebioAn2Protocol Group
----------------------------
wtWebioAn2PrtclUdpPort OBJECT-TYPE
SYNTAX INTEGER (1..65535)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Udp port to which the Udp queries GET Single can be sent"
::= { wtWebioAn2PrtclUDP 1 }
wtWebioAn2PrtclSnmpCommunityStringRead OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Community string read only"
::= { wtWebioAn2PrtclSNMP 1 }
wtWebioAn2PrtclSnmpCommunityStringReadWrite OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Community string read / write"
::= { wtWebioAn2PrtclSNMP 2 }
wtWebioAn2SystemTrapManagerIP OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Name or IP address of the TCP server which accepts the system trap."
::= { wtWebioAn2PrtclSNMP 3 }
wtWebioAn2SystemTrapEnable OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(4))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Binary coded trigger conditions:
Octet 1: unused
Octet 2: unused
Octet 3: unused
Octet 4:
Bit 0: ColdStart
Bit 1: WarmStart
Bit 2-7: unused"
::= { wtWebioAn2PrtclSNMP 4 }
wtWebioAn2PrtclHttpPort OBJECT-TYPE
SYNTAX INTEGER (1..65535)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"HTTP port to which the HTTP queries GET Single can be sent"
::= { wtWebioAn2PrtclHttp 1 }
-- wtWebioAn2Enable Group
----------------------------
wtWebioAn2Enables OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(4))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Binary coded trigger conditions:
Octet 1: unused
Octet 2: unused
Octet 3: unused
Octet 4:
Bit 0: Update enable
Bit 1: Mail enable
Bit 2: Snmp enable
Bit 3: UDP enable
Bit 4: Get Single Header enable
Bit 5: Apply Timezone
Bit 6: Apply Summertime
Bit 7: Apply TimeServer"
::= { wtWebioAn2Enable 1 }
-- wtWebioAn2Startup Group
----------------------------
wtWebioAn2StartupSite OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(4))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Binary coded start page:
Octet 1: unused
Octet 2: unused
Octet 3: unused
Octet 4:
Bit 1: Index.htm
Bit 2: Home.htm
Bit 3: User.htm
Only one page may be selected at a time."
::= { wtWebioAn2Startup 1 }
-- wtWebioAn2Ports Group
----------------------------
-- Table
wtWebioAn2PortTable OBJECT-TYPE
SYNTAX SEQUENCE OF WtWebioAn2PortEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"List of settings depending on the sensor number."
::= { wtWebioAn2Ports 1 }
wtWebioAn2PortEntry OBJECT-TYPE
SYNTAX WtWebioAn2PortEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Sensor parameters for the individual sensor."
INDEX { wtWebioAn2SensorNo }
::= { wtWebioAn2PortTable 1 }
WtWebioAn2PortEntry ::= SEQUENCE {
wtWebioAn2PortName OCTET STRING,
wtWebioAn2PortText OCTET STRING,
wtWebioAn2PortOffset1 OCTET STRING,
wtWebioAn2PortTemperature1 OCTET STRING,
wtWebioAn2PortOffset2 OCTET STRING,
wtWebioAn2PortTemperature2 OCTET STRING,
wtWebioAn2PortComment OCTET STRING
}
wtWebioAn2PortName OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Name of the sensor."
::= { wtWebioAn2PortEntry 1 }
wtWebioAn2PortText OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Description of the sensor."
::= { wtWebioAn2PortEntry 2 }
wtWebioAn2PortOffset1 OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Offset calibration: Offset in degrees with maximum 2 decimal places at temperature 1."
::= { wtWebioAn2PortEntry 3 }
wtWebioAn2PortTemperature1 OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Offset calibration: Reference temperature 1 in degrees with maximum 2 decimal places."
::= { wtWebioAn2PortEntry 4 }
wtWebioAn2PortOffset2 OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Offset calibration: Offset in degrees with maximum 2 decimal places at temperature 2."
::= { wtWebioAn2PortEntry 5 }
wtWebioAn2PortTemperature2 OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Offset calibration: Reference temperature 1 in degrees with maximum 2 decimal places."
::= { wtWebioAn2PortEntry 6 }
wtWebioAn2PortComment OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Offset calibration: informations of date, name of operator, reference devices."
::= { wtWebioAn2PortEntry 7 }
-- wtWebioAn2Manufact Group
----------------------------
wtWebioAn2MfName OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Manufacturer company name"
::= { wtWebioAn2Manufact 1 }
wtWebioAn2MfAddr OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Manufacturer address."
::= { wtWebioAn2Manufact 2 }
wtWebioAn2MfHotline OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Manufacturer hotline."
::= { wtWebioAn2Manufact 3 }
wtWebioAn2MfInternet OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Manufacturer Internet address."
::= { wtWebioAn2Manufact 4 }
wtWebioAn2MfDeviceTyp OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Manufacturer device name (model number)."
::= { wtWebioAn2Manufact 5 }
wtWebioAn2MfOrderNo OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Manufacturer part number."
::= { wtWebioAn2Manufact 6 }
-- TRAP DEFINITIONS
-- Diese SNMP-Traps werden gesendet, wenn die Alarmtriggerbedingungen zutreffen
wtWebioAn2Alert1 TRAP-TYPE
ENTERPRISE wtWebioAn2
VARIABLES { wtWebioAn2AlarmTrapText }
DESCRIPTION
"This SNMP trap is generated when Alarm 1 was triggered,
SNMP trap enable is set and
SNMP is enabled."
-- NMS trap annotation
--#TYPE "WebThermometer Alarm 1"
--#SUMMARY "Alarm 1: %s"
--#ARGUMENTS {0}
--#SEVERITY INFORMATIONAL
--#TIMEINDEX 99
--#STATE OPERATIONAL
::= 21
wtWebioAn2Alert2 TRAP-TYPE
ENTERPRISE wtWebioAn2
VARIABLES { wtWebioAn2AlarmTrapText }
DESCRIPTION
"This SNMP trap is generated when Alarm 2 was triggered,
SNMP trap enable is set and
SNMP is enabled."
-- NMS trap annotation
--#TYPE "WebThermometer Alarm 2"
--#SUMMARY "Alarm 2: %s"
--#ARGUMENTS {0}
--#SEVERITY INFORMATIONAL
--#TIMEINDEX 99
--#STATE OPERATIONAL
::= 22
wtWebioAn2Alert3 TRAP-TYPE
ENTERPRISE wtWebioAn2
VARIABLES { wtWebioAn2AlarmTrapText }
DESCRIPTION
"This SNMP trap is generated when Alarm 3 was triggered,
SNMP trap enable is set and
SNMP is enabled."
-- NMS trap annotation
--#TYPE "WebThermometer Alarm 3"
--#SUMMARY "Alarm 3: %s"
--#ARGUMENTS {0}
--#SEVERITY INFORMATIONAL
--#TIMEINDEX 99
--#STATE OPERATIONAL
::= 23
wtWebioAn2Alert4 TRAP-TYPE
ENTERPRISE wtWebioAn2
VARIABLES { wtWebioAn2AlarmTrapText }
DESCRIPTION
"This SNMP trap is generated when Alarm 4 was triggered,
SNMP trap enable is set and
SNMP is enabled."
-- NMS trap annotation
--#TYPE "WebThermometer Alarm 4"
--#SUMMARY "Alarm 4: %s"
--#ARGUMENTS {0}
--#SEVERITY INFORMATIONAL
--#TIMEINDEX 99
--#STATE OPERATIONAL
::= 24
wtWebioAn2Alert5 TRAP-TYPE
ENTERPRISE wtWebioAn2
VARIABLES { wtWebioAn2AlarmTrapText }
DESCRIPTION
"This SNMP trap is generated when Alarm 5 was triggered,
SNMP trap enable is set and
SNMP is enabled."
-- NMS trap annotation
--#TYPE "WebThermometer Alarm 5"
--#SUMMARY "Alarm 5: %s"
--#ARGUMENTS {0}
--#SEVERITY INFORMATIONAL
--#TIMEINDEX 99
--#STATE OPERATIONAL
::= 25
wtWebioAn2Alert6 TRAP-TYPE
ENTERPRISE wtWebioAn2
VARIABLES { wtWebioAn2AlarmTrapText }
DESCRIPTION
"This SNMP trap is generated when Alarm 6 was triggered,
SNMP trap enable is set and
SNMP is enabled."
-- NMS trap annotation
--#TYPE "WebThermometer Alarm 6"
--#SUMMARY "Alarm 6: %s"
--#ARGUMENTS {0}
--#SEVERITY INFORMATIONAL
--#TIMEINDEX 99
--#STATE OPERATIONAL
::= 26
wtWebioAn2Alert7 TRAP-TYPE
ENTERPRISE wtWebioAn2
VARIABLES { wtWebioAn2AlarmTrapText }
DESCRIPTION
"This SNMP trap is generated when Alarm 7 was triggered,
SNMP trap enable is set and
SNMP is enabled."
-- NMS trap annotation
--#TYPE "WebThermometer Alarm 7"
--#SUMMARY "Alarm 7: %s"
--#ARGUMENTS {0}
--#SEVERITY INFORMATIONAL
--#TIMEINDEX 99
--#STATE OPERATIONAL
::= 27
wtWebioAn2Alert8 TRAP-TYPE
ENTERPRISE wtWebioAn2
VARIABLES { wtWebioAn2AlarmTrapText }
DESCRIPTION
"This SNMP trap is generated when Alarm 8 was triggered,
SNMP trap enable is set and
SNMP is enabled."
-- NMS trap annotation
--#TYPE "WebThermometer Alarm 8"
--#SUMMARY "Alarm 8: %s"
--#ARGUMENTS {0}
--#SEVERITY INFORMATIONAL
--#TIMEINDEX 99
--#STATE OPERATIONAL
::= 28
wtWebioAn2Alert9 TRAP-TYPE
ENTERPRISE wtWebioAn2
VARIABLES { wtWebioAn2AlarmClearTrapText }
DESCRIPTION
"This SNMP trap is generated when Alarm 1 was cleared,
SNMP trap enable is set and
SNMP is enabled."
-- NMS trap annotation
--#TYPE "WebThermometer Release Alarm 1"
--#SUMMARY "Alarm 1: %s"
--#ARGUMENTS {0}
--#SEVERITY INFORMATIONAL
--#TIMEINDEX 99
--#STATE OPERATIONAL
::= 81
wtWebioAn2Alert10 TRAP-TYPE
ENTERPRISE wtWebioAn2
VARIABLES { wtWebioAn2AlarmClearTrapText }
DESCRIPTION
"This SNMP trap is generated when Alarm 2 was cleared,
SNMP trap enable is set and
SNMP is enabled."
-- NMS trap annotation
--#TYPE "WebThermometer Release Alarm 2"
--#SUMMARY "Alarm 2: %s"
--#ARGUMENTS {0}
--#SEVERITY INFORMATIONAL
--#TIMEINDEX 99
--#STATE OPERATIONAL
::= 82
wtWebioAn2Alert11 TRAP-TYPE
ENTERPRISE wtWebioAn2
VARIABLES { wtWebioAn2AlarmClearTrapText }
DESCRIPTION
"This SNMP trap is generated when Alarm 3 was cleared,
SNMP trap enable is set and
SNMP is enabled."
-- NMS trap annotation
--#TYPE "WebThermometer Release Alarm 3"
--#SUMMARY "Alarm 3: %s"
--#ARGUMENTS {0}
--#SEVERITY INFORMATIONAL
--#TIMEINDEX 99
--#STATE OPERATIONAL
::= 83
wtWebioAn2Alert12 TRAP-TYPE
ENTERPRISE wtWebioAn2
VARIABLES { wtWebioAn2AlarmClearTrapText }
DESCRIPTION
"This SNMP trap is generated when Alarm 4 was cleared,
SNMP trap enable is set and
SNMP is enabled."
-- NMS trap annotation
--#TYPE "WebThermometer Release Alarm 4"
--#SUMMARY "Alarm 4: %s"
--#ARGUMENTS {0}
--#SEVERITY INFORMATIONAL
--#TIMEINDEX 99
--#STATE OPERATIONAL
::= 84
wtWebioAn2Alert13 TRAP-TYPE
ENTERPRISE wtWebioAn2
VARIABLES { wtWebioAn2AlarmClearTrapText }
DESCRIPTION
"This SNMP trap is generated when Alarm 5 was cleared,
SNMP trap enable is set and
SNMP is enabled."
-- NMS trap annotation
--#TYPE "WebThermometer Release Alarm 5"
--#SUMMARY "Alarm 5: %s"
--#ARGUMENTS {0}
--#SEVERITY INFORMATIONAL
--#TIMEINDEX 99
--#STATE OPERATIONAL
::= 85
wtWebioAn2Alert14 TRAP-TYPE
ENTERPRISE wtWebioAn2
VARIABLES { wtWebioAn2AlarmClearTrapText }
DESCRIPTION
"This SNMP trap is generated when Alarm 6 was cleared,
SNMP trap enable is set and
SNMP is enabled."
-- NMS trap annotation
--#TYPE "WebThermometer Release Alarm 6"
--#SUMMARY "Alarm 6: %s"
--#ARGUMENTS {0}
--#SEVERITY INFORMATIONAL
--#TIMEINDEX 99
--#STATE OPERATIONAL
::= 86
wtWebioAn2Alert15 TRAP-TYPE
ENTERPRISE wtWebioAn2
VARIABLES { wtWebioAn2AlarmClearTrapText }
DESCRIPTION
"This SNMP trap is generated when Alarm 7 was cleared,
SNMP trap enable is set and
SNMP is enabled."
-- NMS trap annotation
--#TYPE "WebThermometer Release Alarm 7"
--#SUMMARY "Alarm 7: %s"
--#ARGUMENTS {0}
--#SEVERITY INFORMATIONAL
--#TIMEINDEX 99
--#STATE OPERATIONAL
::= 87
wtWebioAn2Alert16 TRAP-TYPE
ENTERPRISE wtWebioAn2
VARIABLES { wtWebioAn2AlarmClearTrapText }
DESCRIPTION
"This SNMP trap is generated when Alarm 8 was cleared,
SNMP trap enable is set and
SNMP is enabled."
-- NMS trap annotation
--#TYPE "WebThermometer Release Alarm 8"
--#SUMMARY "Alarm 8: %s"
--#ARGUMENTS {0}
--#SEVERITY INFORMATIONAL
--#TIMEINDEX 99
--#STATE OPERATIONAL
::= 88
--------------------------------------------------------------------------------
--------------------------------------------------------------------------------
--------------------------------------------------------------------------------
-- wtWebioAn1Temp Group
------------------------
wtWebioAn1Sensors OBJECT-TYPE
SYNTAX INTEGER (1..8)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Number of temperature sensors"
::= { wtWebioAn1Temp 1 }
-- Interface Table
wtWebioAn1SensorTable OBJECT-TYPE
SYNTAX SEQUENCE OF WtWebioAn1SensorEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"List of sensors."
::= { wtWebioAn1Temp 2 }
wtWebioAn1SensorEntry OBJECT-TYPE
SYNTAX WtWebioAn1SensorEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Temperature sensor numbers."
INDEX { wtWebioAn1SensorNo }
::= { wtWebioAn1SensorTable 1 }
WtWebioAn1SensorEntry ::= SEQUENCE {
wtWebioAn1SensorNo INTEGER (1)
}
wtWebioAn1SensorNo OBJECT-TYPE
SYNTAX INTEGER (1)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Temperature sensor number."
::= { wtWebioAn1SensorEntry 1 }
-- wtWebioAn1TempValue Table
wtWebioAn1TempValueTable OBJECT-TYPE
SYNTAX SEQUENCE OF WtWebioAn1TempValueEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"List of temperature values corresponding to the channel numbers."
::= { wtWebioAn1Temp 3 }
wtWebioAn1TempValueEntry OBJECT-TYPE
SYNTAX WtWebioAn1TempValueEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Temperatures of the sensors."
INDEX { wtWebioAn1SensorNo }
::= { wtWebioAn1TempValueTable 1 }
WtWebioAn1TempValueEntry ::= SEQUENCE{
wtWebioAn1TempValue OCTET STRING (SIZE (5))
}
wtWebioAn1TempValue OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (5))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Temperature value of the sensor, ASCII, 5 characters in length."
::= { wtWebioAn1TempValueEntry 1 }
-- wtWebioAn1BinaryTempValue Table
wtWebioAn1BinaryTempValueTable OBJECT-TYPE
SYNTAX SEQUENCE OF WtWebioAn1BinaryTempValueEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"List of binary temperature values corresponding to the channel numbers."
::= { wtWebioAn1Temp 4 }
wtWebioAn1BinaryTempValueEntry OBJECT-TYPE
SYNTAX WtWebioAn1BinaryTempValueEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Binary temperature values of the sensors."
INDEX { wtWebioAn1SensorNo }
::= { wtWebioAn1BinaryTempValueTable 1 }
WtWebioAn1BinaryTempValueEntry ::= SEQUENCE{
wtWebioAn1BinaryTempValue INTEGER
}
wtWebioAn1BinaryTempValue OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Binary temperature value of the sensor in 1/10 degrees Celsius,
signed number, 0x7FFF indicates an
invalid measured value."
::= { wtWebioAn1BinaryTempValueEntry 1 }
-- wtWebioAn1SessCntrl Group
--------------------------------
wtWebioAn1SessCntrlPassword OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Entering this password opens a session which is ended by writing a 1 to
wtWebioAn1SessCntrlLogout. When read this variable provides a string of
length zero."
::= { wtWebioAn1SessCntrl 1 }
wtWebioAn1SessCntrlConfigMode OBJECT-TYPE
SYNTAX INTEGER {
wtWebioAn1SessCntrl-NoSession(0),
wtWebioAn1SessCntrl-Session(1)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"When the device is in SNMP configuration mode, the value 1 is
returned, otherwise 0. If the read value is 0 even though the
password was written, the device is already in config mode and the
variables can only be read."
::= { wtWebioAn1SessCntrl 2 }
wtWebioAn1SessCntrlLogout OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"If the device is in configuration mode and the session was opened by
this SNMP Manager, writing a 1 to this variable will end the session
and all parameters are stored.
Writing a 2 discards all entries again.
When read this variable provides the value 0."
::= { wtWebioAn1SessCntrl 3 }
wtWebioAn1SessCntrlAdminPassword OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This password protects access to the variables with administrator rights.
It can only be changed by the administrator. If no password was assigned,
the valid password is public."
::= { wtWebioAn1SessCntrl 4 }
wtWebioAn1SessCntrlConfigPassword OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This password protects access to the variables with configurator rights. It can
be changed by the administrator and by the configurator. If no password was assigned,
the valid password is public. When read this variable provides a null-pointer."
::= { wtWebioAn1SessCntrl 5 }
-- wtWebioAn1Network Group
------------------------
wtWebioAn1IpAddress OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-write
STATUS mandatory
DESCRIPTION
"IP address of the Webio"
::= { wtWebioAn1Network 1 }
wtWebioAn1SubnetMask OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Subnet mask of the Webio"
::= { wtWebioAn1Network 2 }
wtWebioAn1Gateway OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Gateway of the Webio"
::= { wtWebioAn1Network 3 }
wtWebioAn1DnsServer1 OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"IP address of the 1st DNS server in ASCII"
::= { wtWebioAn1Network 4 }
wtWebioAn1DnsServer2 OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"IP address of the 2nd DNS server in ASCII"
::= { wtWebioAn1Network 5 }
wtWebioAn1AddConfig OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Additional configuration (1=ON):
Octet 1: unused
Octet 2: unused
Octet 3: unused
Octet 4:
Bit 0: BOOTP disable
"
::= { wtWebioAn1Network 6 }
-- wtWebioAn1Text Group
------------------------
wtWebioAn1DeviceName OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Name of the Webio, which is user definable."
::= { wtWebioAn1Text 1 }
wtWebioAn1DeviceText OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Description of the Webio, which is user definable."
::= { wtWebioAn1Text 2 }
wtWebioAn1DeviceLocation OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Description of the location of the Webio, which is user definable."
::= { wtWebioAn1Text 3 }
wtWebioAn1DeviceContact OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Contact address of the system operator of the Webio, which is user definable."
::= { wtWebioAn1Text 4 }
-- wtWebioAn1TimeZone Group
----------------------------
wtWebioAn1TzName OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Name of the time zone (winter time)."
::= { wtWebioAn1TimeZone 1 }
wtWebioAn1TzOffsetHrs OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Offset hours for the time zone (winter time) with respect to UTC."
::= { wtWebioAn1TimeZone 2 }
wtWebioAn1TzOffsetMin OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Offset minutes for the time zone (winter time) with respect to UTC."
::= { wtWebioAn1TimeZone 3 }
wtWebioAn1StTzName OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Name of the time zone (summer time)."
::= { wtWebioAn1TimeZone 4 }
wtWebioAn1StTzOffsetHrs OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Offset hours of the time zone (summer time) with respect to UTC."
::= { wtWebioAn1TimeZone 5 }
wtWebioAn1StTzOffsetMin OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Offset minutes of the time zone (summer time) with respect to UTC."
::= { wtWebioAn1TimeZone 6 }
wtWebioAn1StTzStartMonth OBJECT-TYPE
SYNTAX INTEGER {
wtWebioAn1StartMonth-January(1),
wtWebioAn1StartMonth-February(2),
wtWebioAn1StartMonth-March(3),
wtWebioAn1StartMonth-April(4),
wtWebioAn1StartMonth-May(5),
wtWebioAn1StartMonth-June(6),
wtWebioAn1StartMonth-July(7),
wtWebioAn1StartMonth-August(8),
wtWebioAn1StartMonth-September(9),
wtWebioAn1StartMonth-October(10),
wtWebioAn1StartMonth-November(11),
wtWebioAn1StartMonth-December(12)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Month in which the change is made from winter time to summer time."
::= { wtWebioAn1TimeZone 7 }
wtWebioAn1StTzStartMode OBJECT-TYPE
SYNTAX INTEGER {
wtWebioAn1StartMode-first(1),
wtWebioAn1StartMode-second(2),
wtWebioAn1StartMode-third(3),
wtWebioAn1StartMode-fourth(4),
wtWebioAn1StartMode-last(5)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Mode of the day of the week for which the change is made from winter time to summer time."
::= { wtWebioAn1TimeZone 8 }
wtWebioAn1StTzStartWday OBJECT-TYPE
SYNTAX INTEGER {
wtWebioAn1StartWday-Sunday(1),
wtWebioAn1StartWday-Monday(2),
wtWebioAn1StartWday-Tuesday(3),
wtWebioAn1StartWday-Thursday(4),
wtWebioAn1StartWday-Wednesday(5),
wtWebioAn1StartWday-Friday(6),
wtWebioAn1StartWday-Saturday(7)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Day of the week on which the change is made from winter time to summer time"
::= { wtWebioAn1TimeZone 9 }
wtWebioAn1StTzStartHrs OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Hour in which the time zone is changed from winter to summer time with
respect to UTC."
::= { wtWebioAn1TimeZone 10 }
wtWebioAn1StTzStartMin OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Minute in which the time zone is changed from winter to summer time with
respect to UTC."
::= { wtWebioAn1TimeZone 11 }
wtWebioAn1StTzStopMonth OBJECT-TYPE
SYNTAX INTEGER {
wtWebioAn1StopMonth-January(1),
wtWebioAn1StopMonth-February(2),
wtWebioAn1StopMonth-March(3),
wtWebioAn1StopMonth-April(4),
wtWebioAn1StopMonth-May(5),
wtWebioAn1StopMonth-June(6),
wtWebioAn1StopMonth-July(7),
wtWebioAn1StopMonth-August(8),
wtWebioAn1StopMonth-September(9),
wtWebioAn1StopMonth-October(10),
wtWebioAn1StopMonth-November(11),
wtWebioAn1StopMonth-December(12)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Month in which the change is made from summer time to winter time."
::= { wtWebioAn1TimeZone 12 }
wtWebioAn1StTzStopMode OBJECT-TYPE
SYNTAX INTEGER {
wtWebioAn1StopMode-first(1),
wtWebioAn1StopMode-second(2),
wtWebioAn1StopMode-third(3),
wtWebioAn1StopMode-fourth(4),
wtWebioAn1StopMode-last(5)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Mode of the week day on which the change is made from summer time to winter time."
::= { wtWebioAn1TimeZone 13 }
wtWebioAn1StTzStopWday OBJECT-TYPE
SYNTAX INTEGER {
wtWebioAn1StopWday-Sunday(1),
wtWebioAn1StopWday-Monday(2),
wtWebioAn1StopWday-Tuesday(3),
wtWebioAn1StopWday-Thursday(4),
wtWebioAn1StopWday-Wednesday(5),
wtWebioAn1StopWday-Friday(6),
wtWebioAn1StopWday-Saturday(7)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Day of the week on which the change is made from summer time to winter time."
::= { wtWebioAn1TimeZone 14 }
wtWebioAn1StTzStopHrs OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Hour at which the time zone is changed from summer to winter time with
respect to UTC."
::= { wtWebioAn1TimeZone 15 }
wtWebioAn1StTzStopMin OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Minute at which the time zone is changed from summer to winter time with
respect to UTC."
::= { wtWebioAn1TimeZone 16 }
-- wtWebioAn1TimeServer Group
----------------------------
wtWebioAn1TimeServer1 OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"IP address or name of the 1st time server in ASCII"
::= { wtWebioAn1TimeServer 1 }
wtWebioAn1TimeServer2 OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"IP address or name of the 2nd time server in ASCII"
::= { wtWebioAn1TimeServer 2 }
-- wtWebioAn1DeviceClock Group
----------------------------
wtWebioAn1ClockHrs OBJECT-TYPE
SYNTAX INTEGER (0..23)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Clock hours taking into account the time zone settings."
::= { wtWebioAn1DeviceClock 1 }
wtWebioAn1ClockMin OBJECT-TYPE
SYNTAX INTEGER (0..59)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Clock minutes taking into account the time zone settings."
::= { wtWebioAn1DeviceClock 2 }
wtWebioAn1ClockDay OBJECT-TYPE
SYNTAX INTEGER (1..31)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Date: Day of the month, taking into account the time zone settings."
::= { wtWebioAn1DeviceClock 3 }
wtWebioAn1ClockMonth OBJECT-TYPE
SYNTAX INTEGER {
wtWebioAn1ClockMonth-January(1),
wtWebioAn1ClockMonth-February(2),
wtWebioAn1ClockMonth-March(3),
wtWebioAn1ClockMonth-April(4),
wtWebioAn1ClockMonth-May(5),
wtWebioAn1ClockMonth-June(6),
wtWebioAn1ClockMonth-July(7),
wtWebioAn1ClockMonth-August(8),
wtWebioAn1ClockMonth-September(9),
wtWebioAn1ClockMonth-October(10),
wtWebioAn1ClockMonth-November(11),
wtWebioAn1ClockMonth-December(12)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Date: Month, taking into account the time zone settings."
::= { wtWebioAn1DeviceClock 4 }
wtWebioAn1ClockYear OBJECT-TYPE
SYNTAX INTEGER (0..65535)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Date: Year, taking into account the time zone settings."
::= { wtWebioAn1DeviceClock 5 }
-- wtWebioAn1MailAdmin Group
--------------------------------
wtWebioAn1MailAdName OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Device name for mail administration."
::= { wtWebioAn1MailAdmin 1 }
wtWebioAn1MailReply OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Reply address for the mail server."
::= { wtWebioAn1MailAdmin 2 }
wtWebioAn1MailServer OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Name or IP address of the mail server."
::= { wtWebioAn1MailAdmin 3 }
-- wtWebioAn1Alarm Group
----------------------------
wtWebioAn1AlarmCount OBJECT-TYPE
SYNTAX INTEGER (1..8)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Number of independent alarms."
::= { wtWebioAn1Alarm 1 }
-- Alarm Interface Table
wtWebioAn1AlarmIfTable OBJECT-TYPE
SYNTAX SEQUENCE OF WtWebioAn1AlarmIfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"List of alarm indices."
::= { wtWebioAn1Alarm 2 }
wtWebioAn1AlarmIfEntry OBJECT-TYPE
SYNTAX WtWebioAn1AlarmIfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Numbers of the alarms."
INDEX { wtWebioAn1AlarmNo }
::= { wtWebioAn1AlarmIfTable 1 }
WtWebioAn1AlarmIfEntry ::= SEQUENCE {
wtWebioAn1AlarmNo INTEGER (1..8)
}
wtWebioAn1AlarmNo OBJECT-TYPE
SYNTAX INTEGER (1..8)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Alarm number."
::= { wtWebioAn1AlarmIfEntry 1 }
-- Alarm Table
wtWebioAn1AlarmTable OBJECT-TYPE
SYNTAX SEQUENCE OF WtWebioAn1AlarmEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"List of settings depending on the alarm number."
::= { wtWebioAn1Alarm 3 }
wtWebioAn1AlarmEntry OBJECT-TYPE
SYNTAX WtWebioAn1AlarmEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Alarm parameters of the individual alarms."
INDEX { wtWebioAn1AlarmNo }
::= { wtWebioAn1AlarmTable 1 }
WtWebioAn1AlarmEntry ::= SEQUENCE {
wtWebioAn1AlarmTrigger OCTET STRING,
wtWebioAn1AlarmMin OCTET STRING,
wtWebioAn1AlarmMax OCTET STRING,
wtWebioAn1AlarmInterval OCTET STRING,
wtWebioAn1AlarmEnable OCTET STRING,
wtWebioAn1AlarmEMailAddr OCTET STRING,
wtWebioAn1AlarmMailSubject OCTET STRING,
wtWebioAn1AlarmMailText OCTET STRING,
wtWebioAn1AlarmManagerIP OCTET STRING,
wtWebioAn1AlarmTrapText OCTET STRING,
wtWebioAn1AlarmMailOptions OCTET STRING,
wtWebioAn1AlarmTcpIpAddr OCTET STRING,
wtWebioAn1AlarmTcpPort INTEGER,
wtWebioAn1AlarmTcpText OCTET STRING,
wtWebioAn1AlarmHystersis OCTET STRING,
wtWebioAn1AlarmClearMailSubject OCTET STRING,
wtWebioAn1AlarmClearMailText OCTET STRING,
wtWebioAn1AlarmClearTrapText OCTET STRING,
wtWebioAn1AlarmClearTcpText OCTET STRING
}
wtWebioAn1AlarmTrigger OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(4))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Binary coded trigger condition:
Octet 1: unused
Octet 2: unused
Octet 3: unused
Octet 4:
Bit 0: Sensor 1
Bit 1: Timer
Bit 2: ColdStart
Bit 3: WarmStart"
::= { wtWebioAn1AlarmEntry 1 }
wtWebioAn1AlarmMin OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Minimum temperature in degrees with maximum 2 decimal places."
::= { wtWebioAn1AlarmEntry 2 }
wtWebioAn1AlarmMax OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Maximum temperature in degrees with maximum 2 decimal places."
::= { wtWebioAn1AlarmEntry 3 }
wtWebioAn1AlarmInterval OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Send interval for alarm messages."
::= { wtWebioAn1AlarmEntry 4 }
wtWebioAn1AlarmEnable OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(4))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Binary coded alarm enable:
Octet 1: unused
Octet 2: unused
Octet 3: unused
Octet 4:
Bit 0: Mail Enable
Bit 1: SNMP Trap enable
Bit 2: TCP Client enable"
::= { wtWebioAn1AlarmEntry 5 }
wtWebioAn1AlarmEMailAddr OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"E-Mail address for sending the alarm mail to."
::= { wtWebioAn1AlarmEntry 6 }
wtWebioAn1AlarmMailSubject OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Subject line for alarm mail."
::= { wtWebioAn1AlarmEntry 7 }
wtWebioAn1AlarmMailText OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Alarm mail text: <T1> provides the current temperature.
<Z> provides the current time."
::= { wtWebioAn1AlarmEntry 8 }
wtWebioAn1AlarmManagerIP OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Name or IP address of the SNMP Manager which accepts the trap."
::= { wtWebioAn1AlarmEntry 9 }
wtWebioAn1AlarmTrapText OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This text is sent in the trap body."
::= { wtWebioAn1AlarmEntry 10 }
wtWebioAn1AlarmMailOptions OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(4))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Binary coded options:
Octet 1: unused
Octet 2: unused
Octet 3: unused
Octet 4:
Bit 0 : Attach Thermo.csv Enable
Bit 1-7: unused"
::= { wtWebioAn1AlarmEntry 11 }
wtWebioAn1AlarmTcpIpAddr OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Name or IP address of the TCP server which accepts the trap."
::= { wtWebioAn1AlarmEntry 12 }
wtWebioAn1AlarmTcpPort OBJECT-TYPE
SYNTAX INTEGER (1..65535)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Port number of the TCP server which accepts the trap."
::= { wtWebioAn1AlarmEntry 13 }
wtWebioAn1AlarmTcpText OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This text is sent in the TCP trap body."
::= { wtWebioAn1AlarmEntry 14 }
wtWebioAn1AlarmHysteresis OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Temperature changes of this size clears the alarm state (MAX-hyst, MIN+hyst.)
, in degrees with maximum 2 decimal places."
::= { wtWebioAn1AlarmEntry 15 }
wtWebioAn1AlarmClearMailSubject OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Subject line for alarm clear mail."
::= { wtWebioAn1AlarmEntry 16 }
wtWebioAn1AlarmClearMailText OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Alarm clear mail text: <Tn> provides the current temperature; n = 1..8.
<Z> provides the current time."
::= { wtWebioAn1AlarmEntry 17 }
wtWebioAn1AlarmClearTrapText OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This text is sent in the trap body."
::= { wtWebioAn1AlarmEntry 18 }
wtWebioAn1AlarmClearTcpText OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This text is sent in the TCP trap body."
::= { wtWebioAn1AlarmEntry 19 }
-- wtWebioAn1Datalogger Group
--------------------------------
wtWebioAn1LoggerTimebase OBJECT-TYPE
SYNTAX INTEGER {
wtWebioAn1Datalogger-1Min(1),
wtWebioAn1Datalogger-5Min(2),
wtWebioAn1Datalogger-15Min(3),
wtWebioAn1Datalogger-60Min(4)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Time base of the data logger"
::= { wtWebioAn1Datalogger 1 }
wtWebioAn1LoggerSensorSel OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(4))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Binary coded trigger conditions:
Octet 1: unused
Octet 2: unused
Octet 3: unused
Octet 4:
Bit 0: Sensor 1"
::= { wtWebioAn1Datalogger 2 }
-- wtWebioAn1Protocol Group
----------------------------
wtWebioAn1PrtclUdpPort OBJECT-TYPE
SYNTAX INTEGER (1..65535)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Udp port to which the Udp queries GET Single can be sent"
::= { wtWebioAn1PrtclUDP 1 }
wtWebioAn1PrtclSnmpCommunityStringRead OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Community string read only"
::= { wtWebioAn1PrtclSNMP 1 }
wtWebioAn1PrtclSnmpCommunityStringReadWrite OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Community string read / write"
::= { wtWebioAn1PrtclSNMP 2 }
wtWebioAn1SystemTrapManagerIP OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Name or IP address of the TCP server which accepts the system trap."
::= { wtWebioAn1PrtclSNMP 3 }
wtWebioAn1SystemTrapEnable OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(4))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Binary coded trigger conditions:
Octet 1: unused
Octet 2: unused
Octet 3: unused
Octet 4:
Bit 0: ColdStart
Bit 1: WarmStart
Bit 2-7: unused"
::= { wtWebioAn1PrtclSNMP 4 }
wtWebioAn1PrtclHttpPort OBJECT-TYPE
SYNTAX INTEGER (1..65535)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"HTTP port to which the HTTP queries GET Single can be sent"
::= { wtWebioAn1PrtclHttp 1 }
-- wtWebioAn1Enable Group
----------------------------
wtWebioAn1Enables OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(4))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Binary coded trigger conditions:
Octet 1: unused
Octet 2: unused
Octet 3: unused
Octet 4:
Bit 0: Update enable
Bit 1: Mail enable
Bit 2: Snmp enable
Bit 3: UDP enable
Bit 4: Get Singel Header enable
Bit 5: Apply Timezone
Bit 6: Apply Summertime
Bit 7: Apply TimeServer"
::= { wtWebioAn1Enable 1 }
-- wtWebioAn1Startup Group
----------------------------
wtWebioAn1StartupSite OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(4))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Binary coded start page:
Octet 1: unused
Octet 2: unused
Octet 3: unused
Octet 4:
Bit 1: Index.htm
Bit 2: Home.htm
Bit 3: User.htm
Only one page may be selected at a time."
::= { wtWebioAn1Startup 1 }
-- wtWebioAn1Ports Group
----------------------------
-- Table
wtWebioAn1PortTable OBJECT-TYPE
SYNTAX SEQUENCE OF WtWebioAn1PortEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"List of settings depending on the sensor number."
::= { wtWebioAn1Ports 1 }
wtWebioAn1PortEntry OBJECT-TYPE
SYNTAX WtWebioAn1PortEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Sensor parameters for the individual sensors."
INDEX { wtWebioAn1SensorNo }
::= { wtWebioAn1PortTable 1 }
WtWebioAn1PortEntry ::= SEQUENCE {
wtWebioAn1PortName OCTET STRING,
wtWebioAn1PortText OCTET STRING,
wtWebioAn1PortOffset1 OCTET STRING,
wtWebioAn1PortTemperature1 OCTET STRING,
wtWebioAn1PortOffset2 OCTET STRING,
wtWebioAn1PortTemperature2 OCTET STRING,
wtWebioAn1PortComment OCTET STRING
}
wtWebioAn1PortName OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Name of the sensor."
::= { wtWebioAn1PortEntry 1 }
wtWebioAn1PortText OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Description of the sensor."
::= { wtWebioAn1PortEntry 2 }
wtWebioAn1PortOffset1 OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Offset calibration: Offset in degrees with maximum 2 decimal places at temperature 1."
::= { wtWebioAn1PortEntry 3 }
wtWebioAn1PortTemperature1 OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Offset calibration: Reference temperature 1 in degrees with maximum 2 decimal places."
::= { wtWebioAn1PortEntry 4 }
wtWebioAn1PortOffset2 OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Offset calibration: Offset in degrees with maximum 2 decimal places at temperature 2."
::= { wtWebioAn1PortEntry 5 }
wtWebioAn1PortTemperature2 OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Offset calibration: Reference temperature 1 in degrees with maximum 2 decimal places."
::= { wtWebioAn1PortEntry 6 }
wtWebioAn1PortComment OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Offset calibration: informations of date, name of operator, reference devices."
::= { wtWebioAn1PortEntry 7 }
-- wtWebioAn1Manufact Group
----------------------------
wtWebioAn1MfName OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Manufacturer company name"
::= { wtWebioAn1Manufact 1 }
wtWebioAn1MfAddr OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Manufacturer address."
::= { wtWebioAn1Manufact 2 }
wtWebioAn1MfHotline OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Manufacturer hotline."
::= { wtWebioAn1Manufact 3 }
wtWebioAn1MfInternet OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Manufacturer Internet address."
::= { wtWebioAn1Manufact 4 }
wtWebioAn1MfDeviceTyp OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Manufacturer device name (model number)."
::= { wtWebioAn1Manufact 5 }
wtWebioAn1MfOrderNo OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Manufacturer part number."
::= { wtWebioAn1Manufact 6 }
-- TRAP DEFINITIONS
-- Diese SNMP-Traps werden gesendet, wenn die Alarmtriggerbedingungen zutreffen
wtWebioAn1Alert1 TRAP-TYPE
ENTERPRISE wtWebioAn1
VARIABLES { wtWebioAn1AlarmTrapText }
DESCRIPTION
"This SNMP trap is generated when Alarm 1 was triggered,
SNMP trap enable is set and
SNMP is enabled."
-- NMS trap annotation
--#TYPE "WebThermometer Alarm 1"
--#SUMMARY "Alarm 1: %s"
--#ARGUMENTS {0}
--#SEVERITY INFORMATIONAL
--#TIMEINDEX 99
--#STATE OPERATIONAL
::= 31
wtWebioAn1Alert2 TRAP-TYPE
ENTERPRISE wtWebioAn1
VARIABLES { wtWebioAn1AlarmTrapText }
DESCRIPTION
"This SNMP trap is generated when Alarm 2 was triggered,
SNMP trap enable is set and
SNMP is enabled."
-- NMS trap annotation
--#TYPE "WebThermometer Alarm 2"
--#SUMMARY "Alarm 2: %s"
--#ARGUMENTS {0}
--#SEVERITY INFORMATIONAL
--#TIMEINDEX 99
--#STATE OPERATIONAL
::= 32
wtWebioAn1Alert3 TRAP-TYPE
ENTERPRISE wtWebioAn1
VARIABLES { wtWebioAn1AlarmTrapText }
DESCRIPTION
"This SNMP trap is generated when Alarm 3 was triggered,
SNMP trap enable is set and
SNMP is enabled."
-- NMS trap annotation
--#TYPE "WebThermometer Alarm 3"
--#SUMMARY "Alarm 3: %s"
--#ARGUMENTS {0}
--#SEVERITY INFORMATIONAL
--#TIMEINDEX 99
--#STATE OPERATIONAL
::= 33
wtWebioAn1Alert4 TRAP-TYPE
ENTERPRISE wtWebioAn1
VARIABLES { wtWebioAn1AlarmTrapText }
DESCRIPTION
"This SNMP trap is generated when Alarm 4 was triggered,
SNMP trap enable is set and
SNMP is enabled."
-- NMS trap annotation
--#TYPE "WebThermometer Alarm 4"
--#SUMMARY "Alarm 4: %s"
--#ARGUMENTS {0}
--#SEVERITY INFORMATIONAL
--#TIMEINDEX 99
--#STATE OPERATIONAL
::= 34
wtWebioAn1Alert5 TRAP-TYPE
ENTERPRISE wtWebioAn1
VARIABLES { wtWebioAn1AlarmTrapText }
DESCRIPTION
"This SNMP trap is generated when Alarm 5 was triggered,
SNMP trap enable is set and
SNMP is enabled."
-- NMS trap annotation
--#TYPE "WebThermometer Alarm 5"
--#SUMMARY "Alarm 5: %s"
--#ARGUMENTS {0}
--#SEVERITY INFORMATIONAL
--#TIMEINDEX 99
--#STATE OPERATIONAL
::= 35
wtWebioAn1Alert6 TRAP-TYPE
ENTERPRISE wtWebioAn1
VARIABLES { wtWebioAn1AlarmTrapText }
DESCRIPTION
"This SNMP trap is generated when Alarm 6 was triggered,
SNMP trap enable is set and
SNMP is enabled."
-- NMS trap annotation
--#TYPE "WebThermometer Alarm 6"
--#SUMMARY "Alarm 6: %s"
--#ARGUMENTS {0}
--#SEVERITY INFORMATIONAL
--#TIMEINDEX 99
--#STATE OPERATIONAL
::= 36
wtWebioAn1Alert7 TRAP-TYPE
ENTERPRISE wtWebioAn1
VARIABLES { wtWebioAn1AlarmTrapText }
DESCRIPTION
"This SNMP trap is generated when Alarm 7 was triggered,
SNMP trap enable is set and
SNMP is enabled."
-- NMS trap annotation
--#TYPE "WebThermometer Alarm 7"
--#SUMMARY "Alarm 7: %s"
--#ARGUMENTS {0}
--#SEVERITY INFORMATIONAL
--#TIMEINDEX 99
--#STATE OPERATIONAL
::= 37
wtWebioAn1Alert8 TRAP-TYPE
ENTERPRISE wtWebioAn1
VARIABLES { wtWebioAn1AlarmTrapText }
DESCRIPTION
"This SNMP trap is generated when Alarm 8 was triggered,
SNMP trap enable is set and
SNMP is enabled."
-- NMS trap annotation
--#TYPE "WebThermometer Alarm 8"
--#SUMMARY "Alarm 8: %s"
--#ARGUMENTS {0}
--#SEVERITY INFORMATIONAL
--#TIMEINDEX 99
--#STATE OPERATIONAL
::= 38
wtWebioAn1Alert9 TRAP-TYPE
ENTERPRISE wtWebioAn1
VARIABLES { wtWebioAn1AlarmClearTrapText }
DESCRIPTION
"This SNMP trap is generated when Alarm 1 was cleared,
SNMP trap enable is set and
SNMP is enabled."
-- NMS trap annotation
--#TYPE "WebThermometer Release Alarm 1"
--#SUMMARY "Alarm 1: %s"
--#ARGUMENTS {0}
--#SEVERITY INFORMATIONAL
--#TIMEINDEX 99
--#STATE OPERATIONAL
::= 91
wtWebioAn1Alert10 TRAP-TYPE
ENTERPRISE wtWebioAn1
VARIABLES { wtWebioAn1AlarmClearTrapText }
DESCRIPTION
"This SNMP trap is generated when Alarm 2 was cleared,
SNMP trap enable is set and
SNMP is enabled."
-- NMS trap annotation
--#TYPE "WebThermometer Release Alarm 2"
--#SUMMARY "Alarm 2: %s"
--#ARGUMENTS {0}
--#SEVERITY INFORMATIONAL
--#TIMEINDEX 99
--#STATE OPERATIONAL
::= 92
wtWebioAn1Alert11 TRAP-TYPE
ENTERPRISE wtWebioAn1
VARIABLES { wtWebioAn1AlarmClearTrapText }
DESCRIPTION
"This SNMP trap is generated when Alarm 3 was cleared,
SNMP trap enable is set and
SNMP is enabled."
-- NMS trap annotation
--#TYPE "WebThermometer Release Alarm 3"
--#SUMMARY "Alarm 3: %s"
--#ARGUMENTS {0}
--#SEVERITY INFORMATIONAL
--#TIMEINDEX 99
--#STATE OPERATIONAL
::= 93
wtWebioAn1Alert12 TRAP-TYPE
ENTERPRISE wtWebioAn1
VARIABLES { wtWebioAn1AlarmClearTrapText }
DESCRIPTION
"This SNMP trap is generated when Alarm 4 was cleared,
SNMP trap enable is set and
SNMP is enabled."
-- NMS trap annotation
--#TYPE "WebThermometer Release Alarm 4"
--#SUMMARY "Alarm 4: %s"
--#ARGUMENTS {0}
--#SEVERITY INFORMATIONAL
--#TIMEINDEX 99
--#STATE OPERATIONAL
::= 94
wtWebioAn1Alert13 TRAP-TYPE
ENTERPRISE wtWebioAn1
VARIABLES { wtWebioAn1AlarmClearTrapText }
DESCRIPTION
"This SNMP trap is generated when Alarm 5 was cleared,
SNMP trap enable is set and
SNMP is enabled."
-- NMS trap annotation
--#TYPE "WebThermometer Release Alarm 5"
--#SUMMARY "Alarm 5: %s"
--#ARGUMENTS {0}
--#SEVERITY INFORMATIONAL
--#TIMEINDEX 99
--#STATE OPERATIONAL
::= 95
wtWebioAn1Alert14 TRAP-TYPE
ENTERPRISE wtWebioAn1
VARIABLES { wtWebioAn1AlarmClearTrapText }
DESCRIPTION
"This SNMP trap is generated when Alarm 6 was cleared,
SNMP trap enable is set and
SNMP is enabled."
-- NMS trap annotation
--#TYPE "WebThermometer Release Alarm 6"
--#SUMMARY "Alarm 6: %s"
--#ARGUMENTS {0}
--#SEVERITY INFORMATIONAL
--#TIMEINDEX 99
--#STATE OPERATIONAL
::= 96
wtWebioAn1Alert15 TRAP-TYPE
ENTERPRISE wtWebioAn1
VARIABLES { wtWebioAn1AlarmClearTrapText }
DESCRIPTION
"This SNMP trap is generated when Alarm 7 was cleared,
SNMP trap enable is set and
SNMP is enabled."
-- NMS trap annotation
--#TYPE "WebThermometer Release Alarm 7"
--#SUMMARY "Alarm 7: %s"
--#ARGUMENTS {0}
--#SEVERITY INFORMATIONAL
--#TIMEINDEX 99
--#STATE OPERATIONAL
::= 97
wtWebioAn1Alert16 TRAP-TYPE
ENTERPRISE wtWebioAn1
VARIABLES { wtWebioAn1AlarmClearTrapText }
DESCRIPTION
"This SNMP trap is generated when Alarm 8 was cleared,
SNMP trap enable is set and
SNMP is enabled."
-- NMS trap annotation
--#TYPE "WebThermometer Release Alarm 8"
--#SUMMARY "Alarm 8: %s"
--#ARGUMENTS {0}
--#SEVERITY INFORMATIONAL
--#TIMEINDEX 99
--#STATE OPERATIONAL
::= 98
END