2535 lines
81 KiB
Plaintext
2535 lines
81 KiB
Plaintext
WebGraph-OLD-Thermo-Hygro-Barometer-US-MIB DEFINITIONS ::= BEGIN
|
|
----------------------------------------------------------------
|
|
-- Revison: 1.31
|
|
----------------------------------------------------------------
|
|
-- 03.09.2010 New: wtWebGraphThermoBaroTempValuePkt
|
|
-- Delimeter Dezimalpunkt
|
|
----------------------------------------------------------------
|
|
-- Revison: 1.30
|
|
----------------------------------------------------------------
|
|
-- 14.12.2009 RSS Feed
|
|
-- 08.02.2010 Correction Graph Sensor Color Table
|
|
----------------------------------------------------------------
|
|
-- Revison: 1.29
|
|
----------------------------------------------------------------
|
|
-- 02.06.2008 Correction wtWebGraphThermBaroHTTP
|
|
-- Correction wtWebGraphThermoBaroDiag
|
|
----------------------------------------------------------------
|
|
-- Revison: 1.28
|
|
----------------------------------------------------------------
|
|
-- 19.01.2007 Webio
|
|
-- New Graphics java script base parameter
|
|
----------------------------------------------------------------
|
|
-- Revison: 1.27
|
|
----------------------------------------------------------------
|
|
-- 09.11.2006 Webio
|
|
-- DHCP enable
|
|
----------------------------------------------------------------
|
|
-- Revison: 1.26
|
|
----------------------------------------------------------------
|
|
-- 03.08.2006 wtWebGraphThermoBaroSensorNo corrected
|
|
--
|
|
----------------------------------------------------------------
|
|
-- Revison: 1.25
|
|
----------------------------------------------------------------
|
|
-- 28.06.2006 New: Community String Trap
|
|
--
|
|
----------------------------------------------------------------
|
|
-- Revison: 1.24
|
|
----------------------------------------------------------------
|
|
-- 26.07.2005 #57606, WebGraph Thermo-Hygrometer
|
|
-- CRON timer function
|
|
----------------------------------------------------------------
|
|
-- Revison: 1.23
|
|
----------------------------------------------------------------
|
|
-- 14.07.2005 #57606, WebGraph Thermo-Hygrometer
|
|
-- FTP functions
|
|
----------------------------------------------------------------
|
|
-- Revison: 1.22
|
|
----------------------------------------------------------------
|
|
-- 17.05.2005 #57606, WebGraph Thermo-Hygrometer
|
|
-- Trap NMS annotations
|
|
----------------------------------------------------------------
|
|
-- Revison: 1.21
|
|
----------------------------------------------------------------
|
|
-- 19.04.2005 #57606, WebGraph Themometer
|
|
-- Mail Authentication
|
|
----------------------------------------------------------------
|
|
-- Revison: 1.20
|
|
----------------------------------------------------------------
|
|
-- 05.11.2004 #57606, WebGraph Thermo-Hygrometer
|
|
-- New: Syslog
|
|
--
|
|
----------------------------------------------------------------
|
|
-- Revison: 1.19
|
|
----------------------------------------------------------------
|
|
-- 08.09.2004 #57606 WebGraph Thermo-Hygrometer
|
|
-- New:
|
|
-- wtWebGraphThermoBaroAlarmRHMin
|
|
-- wtWebGraphThermoBaroAlarmRHMax
|
|
-- wtWebGraphThermoBaroAlarmRHHysteresis
|
|
-- wtWebGraphThermoBaroPortSensorSelect
|
|
-- wtWebGraphThermoBaroAlarmDeltaTemp
|
|
-- wtWebGraphThermoBaroAlarmAHMin
|
|
-- wtWebGraphThermoBaroAlarmAHMax
|
|
----------------------------------------------------------------
|
|
-- Revison: 1.18
|
|
----------------------------------------------------------------
|
|
-- 21.07.2004 #57601/3/4, Webio Anx
|
|
-- New:
|
|
-- Diagnosis
|
|
----------------------------------------------------------------
|
|
-- Revison: 1.17
|
|
----------------------------------------------------------------
|
|
-- 28.06.2004 #57630/1/2, Webio Digital
|
|
-- Neu: Puls Mode
|
|
----------------------------------------------------------------
|
|
-- Revison: 1.16
|
|
----------------------------------------------------------------
|
|
-- 16.04.2004 New: #57632, Webio Digital EA24x24
|
|
--
|
|
-- #57630/1, Webio Digital EA12x12
|
|
-- New:
|
|
-- wtWebioEA12x12InputCounterClear
|
|
----------------------------------------------------------------
|
|
-- Revison: 1.15
|
|
----------------------------------------------------------------
|
|
-- 27.02.2004 #57630/1, Webio Digital EA12x12
|
|
-- New:
|
|
-- Length changed to 32 Bit:
|
|
-- wtWebioEA12x12InputValue
|
|
-- wtWebioEA12x12OutputValue
|
|
-- wtWebioEA12x12LoadControlView
|
|
-- wtWebioEA12x12LCShutDownView
|
|
-- wtWebioEA12x12SetOutput
|
|
-- wtWebioEA12x12AlarmInputTrigger
|
|
-- wtWebioEA12x12AlarmOutputTrigger
|
|
-- wtWebioEA12x12PortOutputSafetyState
|
|
----------------------------------------------------------------
|
|
-- Revison: 1.14
|
|
----------------------------------------------------------------
|
|
-- 16.02.2004 #57630/1, Webio Digital EA12x12
|
|
-- New:
|
|
-- Text: Location, Contact
|
|
-- SNMP: ColdStart, WarmStart, ComunityString Read/RW
|
|
-- Alarm: ColdStart / WarmStart trigger
|
|
--
|
|
-- #57601, 1xWebThermometer
|
|
-- #57603, 2xWebThermometer
|
|
-- #57604, 8xWebThermometer
|
|
-- New:
|
|
-- Alarm Hysteresis
|
|
-- Alarm Clear Traps and Mails
|
|
----------------------------------------------------------------
|
|
-- Revison: 1.13
|
|
----------------------------------------------------------------
|
|
-- 05.02.2004 #57601, 1xWebThermometer
|
|
-- #57603, 2xWebThermometer
|
|
-- #57604, 8xWebThermometer
|
|
-- New:
|
|
-- Text: Location, Contact
|
|
-- SNMP: ColdStart, WarmStart, ComunityString Read/RW
|
|
-- Alarm: ColdStart / WarmStart trigger
|
|
----------------------------------------------------------------
|
|
-- Revison: 1.12
|
|
----------------------------------------------------------------
|
|
-- 05.11.2003 #57601, 1xWebThermometer
|
|
-- #57603, 2xWebThermometer
|
|
-- #57604, 8xWebThermometer
|
|
-- New features:
|
|
-- Mail : Option CSV attachment
|
|
-- Port : Offset calibration
|
|
-- Alarm : TCP Client mode
|
|
----------------------------------------------------------------
|
|
-- Revison: 1.11
|
|
----------------------------------------------------------------
|
|
-- 28.10.2003 #57630/1, Webio Digital EA12x12
|
|
-- New features:
|
|
-- Alarm : TCP Client mode
|
|
-- Inputs: Puls filter
|
|
----------------------------------------------------------------
|
|
-- Revison: 1.10
|
|
----------------------------------------------------------------
|
|
-- 22.07.2003 #57630, Webio Digital EA12x12
|
|
-- New navigation tree, new binary modes
|
|
--
|
|
----------------------------------------------------------------
|
|
-- Revison: 1.09
|
|
----------------------------------------------------------------
|
|
-- 24.03.2003 Trap Enterprise (Type 1, 2) corrected
|
|
----------------------------------------------------------------
|
|
-- Revison: 1.08
|
|
----------------------------------------------------------------
|
|
-- 04.03.2003 reconciled the language versions DE/US
|
|
----------------------------------------------------------------
|
|
-- Revison: 1.07
|
|
----------------------------------------------------------------
|
|
-- 25.02.2003 Correction: wtWebioEA12x12LoadControl
|
|
----------------------------------------------------------------
|
|
-- Revison: 1.06
|
|
----------------------------------------------------------------
|
|
-- 24.02.2003 New:
|
|
-- #57630, Webio EA12x12, LoadControl Group
|
|
-- Correction: Trap variable names
|
|
----------------------------------------------------------------
|
|
-- Revison: 1.05
|
|
----------------------------------------------------------------
|
|
-- 21.01.2003 New:
|
|
-- #57630, Webio EA12x12
|
|
----------------------------------------------------------------
|
|
-- Revison: 1.04
|
|
----------------------------------------------------------------
|
|
-- 02.01.2003 New:
|
|
-- #57601, 1xWebThermometer
|
|
-- #57603, 2xWebThermometer, 8 alarms
|
|
----------------------------------------------------------------
|
|
-- Revison: 1.03
|
|
----------------------------------------------------------------
|
|
-- 21.11.2002 New:
|
|
-- #57604, 2xWebThermometer, BOOTP, StartupSite
|
|
-- #57603, 8xWebThermometer, BOOTP, StartupSite
|
|
----------------------------------------------------------------
|
|
-- Revison: 1.02
|
|
----------------------------------------------------------------
|
|
-- 26.07.2002 New:
|
|
-- #57604, 2xWebThermometer
|
|
-- #57603, 8xWebThermometer
|
|
--
|
|
|
|
|
|
IMPORTS
|
|
|
|
OBJECT-TYPE FROM RFC-1212
|
|
TRAP-TYPE FROM RFC-1215
|
|
DisplayString, PhysAddress FROM RFC1213-MIB
|
|
enterprises, TimeTicks, IpAddress, NetworkAddress FROM RFC1155-SMI;
|
|
|
|
|
|
-- IpAddress ::=
|
|
-- [APPLICATION 0]
|
|
-- IMPLICIT OCTET STRING (SIZE (4))
|
|
-- Counter ::=
|
|
-- [APPLICATION 1]
|
|
-- IMPLICIT INTEGER (0..4294967295)
|
|
-- Gauge ::=
|
|
-- [APPLICATION 2]
|
|
-- IMPLICIT INTEGER (0..4294967295)
|
|
-- TimeTicks ::=
|
|
-- [APPLICATION 3]
|
|
-- IMPLICIT INTEGER (0..4294967295)
|
|
|
|
|
|
-- DisplayString ::= OCTET STRING
|
|
-- PhysAddress ::= OCTET STRING
|
|
|
|
-- internet OBJECT IDENTIFIER ::= { iso org(3) dod(6) 1 }
|
|
-- privat OBJECT IDENTIFIER ::= { internet 4 }
|
|
-- enterprises OBJECT IDENTIFIER ::= { privat 1 }
|
|
|
|
|
|
|
|
-- Wiesemann & Theis Com-Server MIB
|
|
|
|
wut OBJECT IDENTIFIER ::= { enterprises 5040 }
|
|
wtComServer OBJECT IDENTIFIER ::= { wut 1 }
|
|
wtWebio OBJECT IDENTIFIER ::= { wtComServer 2 }
|
|
|
|
-- wtWebGraph Tree
|
|
|
|
wtWebGraphThermoBaro OBJECT IDENTIFIER ::= { wtWebio 16 }
|
|
|
|
-- wtWebGraphThermoBaro Tree
|
|
|
|
wtWebGraphThermoBaroTemp OBJECT IDENTIFIER ::= { wtWebGraphThermoBaro 1 }
|
|
wtWebGraphThermoBaroSessCntrl OBJECT IDENTIFIER ::= { wtWebGraphThermoBaro 2 }
|
|
wtWebGraphThermoBaroConfig OBJECT IDENTIFIER ::= { wtWebGraphThermoBaro 3 }
|
|
wtWebGraphThermoBaroDiag OBJECT IDENTIFIER ::= { wtWebGraphThermoBaro 4 }
|
|
|
|
-- wtWebGraphThermoBaroConfig Tree
|
|
|
|
wtWebGraphThermoBaroDevice OBJECT IDENTIFIER ::= { wtWebGraphThermoBaroConfig 1 }
|
|
wtWebGraphThermoBaroPorts OBJECT IDENTIFIER ::= { wtWebGraphThermoBaroConfig 2 }
|
|
wtWebGraphThermoBaroManufact OBJECT IDENTIFIER ::= { wtWebGraphThermoBaroConfig 3 }
|
|
|
|
-- wtWebGraphThermoBaroDevice Tree
|
|
|
|
wtWebGraphThermoBaroText OBJECT IDENTIFIER ::= { wtWebGraphThermoBaroDevice 1 }
|
|
wtWebGraphThermoBaroTimeDate OBJECT IDENTIFIER ::= { wtWebGraphThermoBaroDevice 2 }
|
|
wtWebGraphThermoBaroBasic OBJECT IDENTIFIER ::= { wtWebGraphThermoBaroDevice 3 }
|
|
wtWebGraphThermoBaroDatalogger OBJECT IDENTIFIER ::= { wtWebGraphThermoBaroDevice 4 }
|
|
wtWebGraphThermoBaroAlarm OBJECT IDENTIFIER ::= { wtWebGraphThermoBaroDevice 5 }
|
|
wtWebGraphThermoBaroGraphics OBJECT IDENTIFIER ::= { wtWebGraphThermoBaroDevice 6 }
|
|
|
|
-- wtWebGraphThermoBaroTimeDate Tree
|
|
|
|
wtWebGraphThermoBaroTimeZone OBJECT IDENTIFIER ::= { wtWebGraphThermoBaroTimeDate 1 }
|
|
wtWebGraphThermoBaroTimeServer OBJECT IDENTIFIER ::= { wtWebGraphThermoBaroTimeDate 2 }
|
|
wtWebGraphThermoBaroDeviceClock OBJECT IDENTIFIER ::= { wtWebGraphThermoBaroTimeDate 3 }
|
|
|
|
-- wtWebGraphThermoBaroBasic Tree
|
|
|
|
wtWebGraphThermoBaroNetwork OBJECT IDENTIFIER ::= { wtWebGraphThermoBaroBasic 1 }
|
|
wtWebGraphThermoBaroHTTP OBJECT IDENTIFIER ::= { wtWebGraphThermoBaroBasic 2 }
|
|
wtWebGraphThermoBaroMail OBJECT IDENTIFIER ::= { wtWebGraphThermoBaroBasic 3 }
|
|
wtWebGraphThermoBaroSNMP OBJECT IDENTIFIER ::= { wtWebGraphThermoBaroBasic 4 }
|
|
wtWebGraphThermoBaroUDP OBJECT IDENTIFIER ::= { wtWebGraphThermoBaroBasic 5 }
|
|
wtWebGraphThermoBaroSyslog OBJECT IDENTIFIER ::= { wtWebGraphThermoBaroBasic 6 }
|
|
wtWebGraphThermoBaroFTP OBJECT IDENTIFIER ::= { wtWebGraphThermoBaroBasic 7 }
|
|
wtWebGraphThermoBaroRSS OBJECT IDENTIFIER ::= { wtWebGraphThermoBaroBasic 8 }
|
|
|
|
|
|
-- wtWebGraphThermoBaroGraphics Tree
|
|
|
|
wtWebGraphThermoBaroGraphicsBase OBJECT IDENTIFIER ::= { wtWebGraphThermoBaroGraphics 1 }
|
|
wtWebGraphThermoBaroGraphicsSelect OBJECT IDENTIFIER ::= { wtWebGraphThermoBaroGraphics 2 }
|
|
wtWebGraphThermoBaroGraphicsScale OBJECT IDENTIFIER ::= { wtWebGraphThermoBaroGraphics 3 }
|
|
|
|
-- wtWebGraphThermoBaroTemp Group
|
|
------------------------
|
|
|
|
wtWebGraphThermoBaroSensors OBJECT-TYPE
|
|
SYNTAX INTEGER (1..2)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Number of sensors"
|
|
::= { wtWebGraphThermoBaroTemp 1 }
|
|
|
|
-- Interface Table
|
|
|
|
wtWebGraphThermoBaroSensorTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF WtWebGraphThermoBaroSensorEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"List of sensors."
|
|
::= { wtWebGraphThermoBaroTemp 2 }
|
|
|
|
wtWebGraphThermoBaroSensorEntry OBJECT-TYPE
|
|
SYNTAX WtWebGraphThermoBaroSensorEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"List of sensor numbers."
|
|
INDEX { wtWebGraphThermoBaroSensorNo }
|
|
::= { wtWebGraphThermoBaroSensorTable 1 }
|
|
|
|
WtWebGraphThermoBaroSensorEntry ::= SEQUENCE {
|
|
wtWebGraphThermoBaroSensorNo INTEGER
|
|
}
|
|
|
|
wtWebGraphThermoBaroSensorNo OBJECT-TYPE
|
|
SYNTAX INTEGER (1..2)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Sensor number."
|
|
::= { wtWebGraphThermoBaroSensorEntry 1 }
|
|
|
|
|
|
-- wtWebGraphThermoBaroTempValue Table
|
|
|
|
wtWebGraphThermoBaroTempValueTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF WtWebGraphThermoBaroTempValueEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"List of measurement values corresponding to the channel numbers."
|
|
::= { wtWebGraphThermoBaroTemp 3 }
|
|
|
|
wtWebGraphThermoBaroTempValueEntry OBJECT-TYPE
|
|
SYNTAX WtWebGraphThermoBaroTempValueEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Measurement values of the sensors."
|
|
INDEX { wtWebGraphThermoBaroSensorNo }
|
|
::= { wtWebGraphThermoBaroTempValueTable 1 }
|
|
|
|
WtWebGraphThermoBaroTempValueEntry ::= SEQUENCE{
|
|
wtWebGraphThermoBaroTempValue OCTET STRING
|
|
}
|
|
|
|
wtWebGraphThermoBaroTempValue OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (5))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Measurement value of the sensor, ASCII, 5 characters in length."
|
|
::= { wtWebGraphThermoBaroTempValueEntry 1 }
|
|
|
|
-- wtWebGraphThermoBaroBinaryTempValue Table
|
|
|
|
wtWebGraphThermoBaroBinaryTempValueTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF WtWebGraphThermoBaroBinaryTempValueEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"List of binary measurement values corresponding to the channel numbers."
|
|
::= { wtWebGraphThermoBaroTemp 4 }
|
|
|
|
wtWebGraphThermoBaroBinaryTempValueEntry OBJECT-TYPE
|
|
SYNTAX WtWebGraphThermoBaroBinaryTempValueEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Binary measurement values of the sensors."
|
|
INDEX { wtWebGraphThermoBaroSensorNo }
|
|
::= { wtWebGraphThermoBaroBinaryTempValueTable 1 }
|
|
|
|
WtWebGraphThermoBaroBinaryTempValueEntry ::= SEQUENCE{
|
|
wtWebGraphThermoBaroBinaryTempValue INTEGER
|
|
}
|
|
|
|
wtWebGraphThermoBaroBinaryTempValue OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Binary measurement value of the sensor in 1/10 degrees Celsius or 1/10 per cent,
|
|
signed number, 0x4FFF6 indicates an
|
|
invalid measured value."
|
|
::= { wtWebGraphThermoBaroBinaryTempValueEntry 1 }
|
|
|
|
-- wtWebGraphThermoBaroTempValuePkt Table
|
|
|
|
wtWebGraphThermoBaroTempValuePktTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF WtWebGraphThermoBaroTempValuePktEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"List of measurement values corresponding to the channel numbers."
|
|
::= { wtWebGraphThermoBaroTemp 8 }
|
|
|
|
wtWebGraphThermoBaroTempValuePktEntry OBJECT-TYPE
|
|
SYNTAX WtWebGraphThermoBaroTempValuePktEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Measurement values of the sensors."
|
|
INDEX { wtWebGraphThermoBaroSensorNo }
|
|
::= { wtWebGraphThermoBaroTempValuePktTable 1 }
|
|
|
|
WtWebGraphThermoBaroTempValuePktEntry ::= SEQUENCE{
|
|
wtWebGraphThermoBaroTempValuePkt OCTET STRING
|
|
}
|
|
|
|
wtWebGraphThermoBaroTempValuePkt OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (5))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Measurement value of the sensor, ASCII, 5 characters in length, delimeter is decimal point."
|
|
::= { wtWebGraphThermoBaroTempValuePktEntry 1 }
|
|
|
|
-- wtWebGraphThermoBaroSessCntrl Group
|
|
--------------------------------
|
|
|
|
wtWebGraphThermoBaroSessCntrlPassword OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Entering this password opens a session which is ended by writing a 1 to
|
|
wtWebGraphThermoBaroSessCntrlLogout. When read this variable provides a string of
|
|
length zero."
|
|
::= { wtWebGraphThermoBaroSessCntrl 1 }
|
|
|
|
wtWebGraphThermoBaroSessCntrlConfigMode OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
wtWebGraphThermoBaroSessCntrl-NoSession(0),
|
|
wtWebGraphThermoBaroSessCntrl-Session(1)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"When the device is in SNMP configuration mode, the value 1 is
|
|
returned, otherwise 0. If the read value is 0 even though the
|
|
password was written, the device is already in config mode and the
|
|
variables can only be read."
|
|
::= { wtWebGraphThermoBaroSessCntrl 2 }
|
|
|
|
wtWebGraphThermoBaroSessCntrlLogout OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"If the device is in configuration mode and the session was opened by
|
|
this SNMP Manager, writing a 1 to this variable will end the session
|
|
and all parameters are stored.
|
|
Writing a 2 discards all entries again.
|
|
When read this variable provides the value 0."
|
|
::= { wtWebGraphThermoBaroSessCntrl 3 }
|
|
|
|
wtWebGraphThermoBaroSessCntrlAdminPassword OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This password protects access to the variables with administrator rights.
|
|
It can only be changed by the administrator. If no password was assigned,
|
|
the valid password is public."
|
|
::= { wtWebGraphThermoBaroSessCntrl 4 }
|
|
|
|
wtWebGraphThermoBaroSessCntrlConfigPassword OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This password protects access to the variables with configurator rights. It can
|
|
be changed by the administrator and by the configurator. If no password was assigned,
|
|
the valid password is public. When read this variable provides a null-pointer."
|
|
::= { wtWebGraphThermoBaroSessCntrl 5 }
|
|
|
|
|
|
-- wtWebGraphThermoBaroText Group
|
|
------------------------
|
|
|
|
wtWebGraphThermoBaroDeviceName OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Name of the Webio, which is user definable."
|
|
::= { wtWebGraphThermoBaroText 1 }
|
|
|
|
wtWebGraphThermoBaroDeviceText OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Description of the Webio, which is user definable."
|
|
::= { wtWebGraphThermoBaroText 2 }
|
|
|
|
wtWebGraphThermoBaroDeviceLocation OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Description of the location of the Webio, which is user definable."
|
|
::= { wtWebGraphThermoBaroText 3 }
|
|
|
|
wtWebGraphThermoBaroDeviceContact OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Contact address of the system operator of the Webio, which is user definable."
|
|
::= { wtWebGraphThermoBaroText 4 }
|
|
|
|
-- wtWebGraphThermoBaroTimeZone Group
|
|
----------------------------
|
|
|
|
wtWebGraphThermoBaroTzOffsetHrs OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Offset hours for the time zone (winter time) with respect to UTC."
|
|
::= { wtWebGraphThermoBaroTimeZone 1 }
|
|
|
|
wtWebGraphThermoBaroTzOffsetMin OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Offset minutes for the time zone (winter time) with respect to UTC."
|
|
::= { wtWebGraphThermoBaroTimeZone 2 }
|
|
|
|
wtWebGraphThermoBaroTzEnable OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Binary coded conditions:
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 1-7: unused
|
|
Bit 0 : Apply Timezone"
|
|
::= { wtWebGraphThermoBaroTimeZone 3 }
|
|
|
|
wtWebGraphThermoBaroStTzOffsetHrs OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Offset hours of the time zone (summer time) with respect to UTC."
|
|
::= { wtWebGraphThermoBaroTimeZone 4 }
|
|
|
|
wtWebGraphThermoBaroStTzOffsetMin OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Offset minutes of the time zone (summer time) with respect to UTC."
|
|
::= { wtWebGraphThermoBaroTimeZone 5 }
|
|
|
|
wtWebGraphThermoBaroStTzEnable OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Binary coded conditions:
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 1-7: unused
|
|
Bit 0 : Apply Summertime"
|
|
::= { wtWebGraphThermoBaroTimeZone 6 }
|
|
|
|
wtWebGraphThermoBaroStTzStartMonth OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
wtWebGraphThermoBaroStartMonth-January(1),
|
|
wtWebGraphThermoBaroStartMonth-February(2),
|
|
wtWebGraphThermoBaroStartMonth-March(3),
|
|
wtWebGraphThermoBaroStartMonth-April(4),
|
|
wtWebGraphThermoBaroStartMonth-May(5),
|
|
wtWebGraphThermoBaroStartMonth-June(6),
|
|
wtWebGraphThermoBaroStartMonth-July(7),
|
|
wtWebGraphThermoBaroStartMonth-August(8),
|
|
wtWebGraphThermoBaroStartMonth-September(9),
|
|
wtWebGraphThermoBaroStartMonth-October(10),
|
|
wtWebGraphThermoBaroStartMonth-November(11),
|
|
wtWebGraphThermoBaroStartMonth-December(12)
|
|
}
|
|
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Month in which the change is made from winter time to summer time."
|
|
::= { wtWebGraphThermoBaroTimeZone 7 }
|
|
|
|
wtWebGraphThermoBaroStTzStartMode OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
wtWebGraphThermoBaroStartMode-first(1),
|
|
wtWebGraphThermoBaroStartMode-second(2),
|
|
wtWebGraphThermoBaroStartMode-third(3),
|
|
wtWebGraphThermoBaroStartMode-fourth(4),
|
|
wtWebGraphThermoBaroStartMode-last(5)
|
|
}
|
|
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Mode of the day of the week for which the change is made from winter time to summer time."
|
|
::= { wtWebGraphThermoBaroTimeZone 8 }
|
|
|
|
wtWebGraphThermoBaroStTzStartWday OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
wtWebGraphThermoBaroStartWday-Sunday(1),
|
|
wtWebGraphThermoBaroStartWday-Monday(2),
|
|
wtWebGraphThermoBaroStartWday-Tuesday(3),
|
|
wtWebGraphThermoBaroStartWday-Thursday(4),
|
|
wtWebGraphThermoBaroStartWday-Wednesday(5),
|
|
wtWebGraphThermoBaroStartWday-Friday(6),
|
|
wtWebGraphThermoBaroStartWday-Saturday(7)
|
|
}
|
|
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Day of the week on which the change is made from winter time to summer time"
|
|
::= { wtWebGraphThermoBaroTimeZone 9 }
|
|
|
|
wtWebGraphThermoBaroStTzStartHrs OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Hour in which the time zone is changed from winter to summer time with
|
|
respect to UTC."
|
|
::= { wtWebGraphThermoBaroTimeZone 10 }
|
|
|
|
wtWebGraphThermoBaroStTzStartMin OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Minute in which the time zone is changed from winter to summer time with
|
|
respect to UTC."
|
|
::= { wtWebGraphThermoBaroTimeZone 11 }
|
|
|
|
wtWebGraphThermoBaroStTzStopMonth OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
wtWebGraphThermoBaroStopMonth-January(1),
|
|
wtWebGraphThermoBaroStopMonth-February(2),
|
|
wtWebGraphThermoBaroStopMonth-March(3),
|
|
wtWebGraphThermoBaroStopMonth-April(4),
|
|
wtWebGraphThermoBaroStopMonth-May(5),
|
|
wtWebGraphThermoBaroStopMonth-June(6),
|
|
wtWebGraphThermoBaroStopMonth-July(7),
|
|
wtWebGraphThermoBaroStopMonth-August(8),
|
|
wtWebGraphThermoBaroStopMonth-September(9),
|
|
wtWebGraphThermoBaroStopMonth-October(10),
|
|
wtWebGraphThermoBaroStopMonth-November(11),
|
|
wtWebGraphThermoBaroStopMonth-December(12)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Month in which the change is made from summer time to winter time."
|
|
::= { wtWebGraphThermoBaroTimeZone 12 }
|
|
|
|
wtWebGraphThermoBaroStTzStopMode OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
wtWebGraphThermoBaroStopMode-first(1),
|
|
wtWebGraphThermoBaroStopMode-second(2),
|
|
wtWebGraphThermoBaroStopMode-third(3),
|
|
wtWebGraphThermoBaroStopMode-fourth(4),
|
|
wtWebGraphThermoBaroStopMode-last(5)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Mode of the week day on which the change is made from summer time to winter time."
|
|
::= { wtWebGraphThermoBaroTimeZone 13 }
|
|
|
|
wtWebGraphThermoBaroStTzStopWday OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
wtWebGraphThermoBaroStopWday-Sunday(1),
|
|
wtWebGraphThermoBaroStopWday-Monday(2),
|
|
wtWebGraphThermoBaroStopWday-Tuesday(3),
|
|
wtWebGraphThermoBaroStopWday-Thursday(4),
|
|
wtWebGraphThermoBaroStopWday-Wednesday(5),
|
|
wtWebGraphThermoBaroStopWday-Friday(6),
|
|
wtWebGraphThermoBaroStopWday-Saturday(7)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Day of the week on which the change is made from summer time to winter time."
|
|
::= { wtWebGraphThermoBaroTimeZone 14 }
|
|
|
|
wtWebGraphThermoBaroStTzStopHrs OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Hour at which the time zone is changed from summer to winter time with
|
|
respect to UTC."
|
|
::= { wtWebGraphThermoBaroTimeZone 15 }
|
|
|
|
wtWebGraphThermoBaroStTzStopMin OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Minute at which the time zone is changed from summer to winter time with
|
|
respect to UTC."
|
|
::= { wtWebGraphThermoBaroTimeZone 16 }
|
|
|
|
-- wtWebGraphThermoBaroTimeServer Group
|
|
----------------------------
|
|
|
|
wtWebGraphThermoBaroTimeServer1 OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"IP address or name of the 1st time server in ASCII"
|
|
::= { wtWebGraphThermoBaroTimeServer 1 }
|
|
|
|
wtWebGraphThermoBaroTimeServer2 OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"IP address or name of the 2nd time server in ASCII"
|
|
::= { wtWebGraphThermoBaroTimeServer 2 }
|
|
|
|
wtWebGraphThermoBaroTsEnable OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Binary coded conditions:
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 1-7: unused
|
|
Bit 0 : Apply Time Server"
|
|
::= { wtWebGraphThermoBaroTimeServer 3 }
|
|
|
|
wtWebGraphThermoBaroTsSyncTime OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Daily synchronisation time with the time server (hour: 0-23)."
|
|
::= { wtWebGraphThermoBaroTimeServer 4 }
|
|
|
|
-- wtWebGraphThermoBaroDeviceClock Group
|
|
----------------------------
|
|
|
|
wtWebGraphThermoBaroClockHrs OBJECT-TYPE
|
|
SYNTAX INTEGER (0..23)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Clock hours taking into account the time zone settings."
|
|
::= { wtWebGraphThermoBaroDeviceClock 1 }
|
|
|
|
wtWebGraphThermoBaroClockMin OBJECT-TYPE
|
|
SYNTAX INTEGER (0..59)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Clock minutes taking into account the time zone settings."
|
|
::= { wtWebGraphThermoBaroDeviceClock 2 }
|
|
|
|
wtWebGraphThermoBaroClockDay OBJECT-TYPE
|
|
SYNTAX INTEGER (1..31)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Date: Day of the month, taking into account the time zone settings."
|
|
::= { wtWebGraphThermoBaroDeviceClock 3 }
|
|
|
|
wtWebGraphThermoBaroClockMonth OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
wtWebGraphThermoBaroClockMonth-January(1),
|
|
wtWebGraphThermoBaroClockMonth-February(2),
|
|
wtWebGraphThermoBaroClockMonth-March(3),
|
|
wtWebGraphThermoBaroClockMonth-April(4),
|
|
wtWebGraphThermoBaroClockMonth-May(5),
|
|
wtWebGraphThermoBaroClockMonth-June(6),
|
|
wtWebGraphThermoBaroClockMonth-July(7),
|
|
wtWebGraphThermoBaroClockMonth-August(8),
|
|
wtWebGraphThermoBaroClockMonth-September(9),
|
|
wtWebGraphThermoBaroClockMonth-October(10),
|
|
wtWebGraphThermoBaroClockMonth-November(11),
|
|
wtWebGraphThermoBaroClockMonth-December(12)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Date: Month, taking into account the time zone settings."
|
|
::= { wtWebGraphThermoBaroDeviceClock 4 }
|
|
|
|
wtWebGraphThermoBaroClockYear OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65535)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Date: Year, taking into account the time zone settings."
|
|
::= { wtWebGraphThermoBaroDeviceClock 5 }
|
|
|
|
|
|
-- wtWebGraphThermoBaroNetwork Group
|
|
------------------------
|
|
|
|
wtWebGraphThermoBaroIpAddress OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"IP address of the Webio"
|
|
::= { wtWebGraphThermoBaroNetwork 1 }
|
|
|
|
wtWebGraphThermoBaroSubnetMask OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Subnet mask of the Webio"
|
|
::= { wtWebGraphThermoBaroNetwork 2 }
|
|
|
|
wtWebGraphThermoBaroGateway OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Gateway of the Webio"
|
|
::= { wtWebGraphThermoBaroNetwork 3 }
|
|
|
|
wtWebGraphThermoBaroDnsServer1 OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"IP address of the 1st DNS server in ASCII"
|
|
::= { wtWebGraphThermoBaroNetwork 4 }
|
|
|
|
wtWebGraphThermoBaroDnsServer2 OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"IP address of the 2nd DNS server in ASCII"
|
|
::= { wtWebGraphThermoBaroNetwork 5 }
|
|
|
|
wtWebGraphThermoBaroAddConfig OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Additional configuration (1=ON):
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 1: DHCP disable
|
|
Bit 0: BOOTP disable
|
|
"
|
|
::= { wtWebGraphThermoBaroNetwork 6 }
|
|
|
|
-- wtWebGraphThermoBaroHTTP Group
|
|
--------------------------------
|
|
|
|
wtWebGraphThermoBaroStartup OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Binary coded start page:
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 1: Index.htm
|
|
Bit 2: Home.htm
|
|
Bit 3: User.htm
|
|
Only one page may be selected at a time."
|
|
::= { wtWebGraphThermoBaroHTTP 1 }
|
|
|
|
wtWebGraphThermoBaroGetHeaderEnable OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"If these bits are set, every answer of a short form GET question will be lead
|
|
by the IP-address and name of the device and/or a HTTP header:
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 1-6: unused
|
|
Bit 1 : GET HTTP enable
|
|
Bit 0 : GET Header enable"
|
|
::= { wtWebGraphThermoBaroHTTP 2 }
|
|
|
|
wtWebGraphThermoBaroHttpPort OBJECT-TYPE
|
|
SYNTAX INTEGER (1..65535)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Definition of the standard HTML port (Default: 80)."
|
|
::= { wtWebGraphThermoBaroHTTP 3 }
|
|
|
|
|
|
-- wtWebGraphThermoBaroMail Group
|
|
--------------------------------
|
|
|
|
wtWebGraphThermoBaroMailAdName OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Device name for mail administration."
|
|
::= { wtWebGraphThermoBaroMail 1 }
|
|
|
|
wtWebGraphThermoBaroMailReply OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Reply address for the mail server."
|
|
::= { wtWebGraphThermoBaroMail 2 }
|
|
|
|
wtWebGraphThermoBaroMailServer OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Name or IP address of the mail server."
|
|
::= { wtWebGraphThermoBaroMail 3 }
|
|
|
|
wtWebioAn1MailEnable OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Set this bit to enable the sending of mails:
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 1-7: unused
|
|
Bit 0 : Mail enable"
|
|
::= { wtWebGraphThermoBaroMail 4 }
|
|
|
|
wtWebGraphThermoBaroMailAuthentication OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Selection of the authentication modi:
|
|
The OCTETS are interpreted bit-by-bit, with each bit corresponding to an output.
|
|
Bit 0 corresponds to the LSB.
|
|
OCTET 1: unused
|
|
OCTET 2: unused
|
|
OCTET 3: unused
|
|
OCTET 4: Bit 3-7: unused
|
|
Bit 2 : POP3 before SMTP
|
|
Bit 1 : ESMTP, authentication
|
|
Bit 0 : SMTP, no authentication"
|
|
::= { wtWebGraphThermoBaroMail 5 }
|
|
|
|
wtWebGraphThermoBaroMailAuthUser OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Name of the user to be authenticated."
|
|
::= { wtWebGraphThermoBaroMail 6 }
|
|
|
|
wtWebGraphThermoBaroMailAuthPassword OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Authentication password."
|
|
::= { wtWebGraphThermoBaroMail 7 }
|
|
|
|
wtWebGraphThermoBaroMailPop3Server OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Name or Ip-address of the POP3 Servers."
|
|
::= { wtWebGraphThermoBaroMail 8 }
|
|
|
|
-- wtWebGraphThermoBaroSNMP Group
|
|
--------------------------------
|
|
|
|
wtWebGraphThermoBaroSnmpCommunityStringRead OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Community string read only"
|
|
::= { wtWebGraphThermoBaroSNMP 1 }
|
|
|
|
wtWebGraphThermoBaroSnmpCommunityStringReadWrite OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Community string read / write"
|
|
::= { wtWebGraphThermoBaroSNMP 2 }
|
|
|
|
wtWebGraphThermoBaroSystemTrapManagerIP OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Name or IP address of the TCP server which accepts the system trap."
|
|
::= { wtWebGraphThermoBaroSNMP 3 }
|
|
|
|
wtWebGraphThermoBaroSystemTrapEnable OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Binary coded trigger conditions:
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 0: ColdStart
|
|
Bit 1: WarmStart
|
|
Bit 2-7: unused"
|
|
::= { wtWebGraphThermoBaroSNMP 4 }
|
|
|
|
wtWebGraphThermoBaroSnmpEnable OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Set bit 0 to enable SNMP.
|
|
If disabled, the device did not respond to any SNMP requests.
|
|
Bit 1 decided wether the community string of read operations
|
|
is compared with the system password or not:
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 1-7: unused
|
|
Bit 0 : SNMP enable"
|
|
::= { wtWebGraphThermoBaroSNMP 5 }
|
|
|
|
wtWebGraphThermoBaroSnmpCommunityStringTrap OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Community string send within traps."
|
|
::= { wtWebGraphThermoBaroSNMP 6 }
|
|
|
|
|
|
-- wtWebGraphThermoBaroUDP Group
|
|
--------------------------------
|
|
|
|
wtWebGraphThermoBaroUdpPort OBJECT-TYPE
|
|
SYNTAX INTEGER (1..65535)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Udp port to which the Udp queries ( short form GET requests) can be sent. This
|
|
port number must be unique within the device."
|
|
::= { wtWebGraphThermoBaroUDP 1 }
|
|
|
|
wtWebGraphThermoBaroUdpEnable OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Set this bit to enable UDP support:
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 1-7: unused
|
|
Bit 0 : UDP enable"
|
|
::= { wtWebGraphThermoBaroUDP 2 }
|
|
|
|
-- wtWebGraphThermoBaroSyslog Group
|
|
--------------------------------
|
|
|
|
wtWebGraphThermoBaroSyslogServerIP OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Name or IP address of the Syslog server, which accepts the Syslog messgaes."
|
|
::= { wtWebGraphThermoBaroSyslog 1 }
|
|
|
|
wtWebGraphThermoBaroSyslogServerPort OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Portnumber of the Syslog servers, default 514."
|
|
::= { wtWebGraphThermoBaroSyslog 2 }
|
|
|
|
wtWebGraphThermoBaroSyslogSystemMessagesEnable OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Binary coded trigger conditions:
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 0: ColdStart
|
|
Bit 1: WarmStart
|
|
Bit 2: Diag Messages
|
|
Bit 3-7: unused"
|
|
::= { wtWebGraphThermoBaroSyslog 3 }
|
|
|
|
wtWebGraphThermoBaroSyslogEnable OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Set bit 0to enable Syslog:
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 1-7: unused
|
|
Bit 0 : Syslog enable"
|
|
::= { wtWebGraphThermoBaroSyslog 4 }
|
|
|
|
-- wtWebGraphThermoBaroFTP Group
|
|
--------------------------------
|
|
|
|
wtWebGraphThermoBaroFTPServerIP OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Name or IP address of the FTP server, which accepts the FTP messages."
|
|
::= { wtWebGraphThermoBaroFTP 1 }
|
|
|
|
wtWebGraphThermoBaroFTPServerControlPort OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Portnumber of the control port of the FTP server, default 21."
|
|
::= { wtWebGraphThermoBaroFTP 2 }
|
|
|
|
wtWebGraphThermoBaroFTPUserName OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"FTP Loggin: user name."
|
|
::= { wtWebGraphThermoBaroFTP 3 }
|
|
|
|
wtWebGraphThermoBaroFTPPassword OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"FTP Loggin: user password."
|
|
::= { wtWebGraphThermoBaroFTP 4 }
|
|
|
|
wtWebGraphThermoBaroFTPAccount OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"FTP Loggin: name of account."
|
|
::= { wtWebGraphThermoBaroFTP 5 }
|
|
|
|
wtWebGraphThermoBaroFTPOption OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Bit 0 switches the FTP Server in Passiv-Mode,
|
|
the Client controls the data connection on its own:
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 1-7: unused
|
|
Bit 0 : PASV enable"
|
|
::= { wtWebGraphThermoBaroFTP 6 }
|
|
|
|
wtWebGraphThermoBaroFTPEnable OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Set Bit 0 to enable FTP:
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 1-7: unused
|
|
Bit 0 : FTP enable"
|
|
::= { wtWebGraphThermoBaroFTP 7 }
|
|
|
|
|
|
-- wtWebGraphThermoBaroDatalogger Group
|
|
--------------------------------
|
|
|
|
wtWebGraphThermoBaroLoggerTimebase OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
wtWebGraphThermoBaroDatalogger-1Min(1),
|
|
wtWebGraphThermoBaroDatalogger-5Min(2),
|
|
wtWebGraphThermoBaroDatalogger-15Min(3),
|
|
wtWebGraphThermoBaroDatalogger-60Min(4)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Time base of the data logger"
|
|
::= { wtWebGraphThermoBaroDatalogger 1 }
|
|
|
|
wtWebGraphThermoBaroLoggerSensorSel OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Binary coded trigger conditions:
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 0: Sensor 1
|
|
Bit 1: Sensor 2
|
|
Bit 2-7: unused"
|
|
::= { wtWebGraphThermoBaroDatalogger 2 }
|
|
|
|
-- wtWebGraphThermoBaroRSS Group
|
|
--------------------------------
|
|
|
|
wtWebGraphThermoBaroRSSChannelTitle OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Name of the RSS Feed."
|
|
::= { wtWebGraphThermoBaroRSS 1 }
|
|
|
|
wtWebGraphThermoBaroRSSChannelLink OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Link of the RSS Feed."
|
|
::= { wtWebGraphThermoBaroRSS 2 }
|
|
|
|
wtWebGraphThermoBaroRSSChannelDescription OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Description of the RSS Feed."
|
|
::= { wtWebGraphThermoBaroRSS 3 }
|
|
|
|
wtWebGraphThermoBaroRSSChannelImage OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Link of a picture, which will be shown at the headline of the output window."
|
|
::= { wtWebGraphThermoBaroRSS 4 }
|
|
|
|
wtWebGraphThermoBaroRSSChannelImageTitle OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Alias Name of the picture."
|
|
::= { wtWebGraphThermoBaroRSS 5 }
|
|
|
|
wtWebGraphThermoBaroRSSChannelImageLink OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Link, which can be selected by clicking on the picture."
|
|
::= { wtWebGraphThermoBaroRSS 6 }
|
|
|
|
wtWebGraphThermoBaroRSSChannelItemTitle OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Title of the RSS Feed."
|
|
::= { wtWebGraphThermoBaroRSS 7 }
|
|
|
|
wtWebGraphThermoBaroRSSChannelItemLink OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Link of the RSS Feed."
|
|
::= { wtWebGraphThermoBaroRSS 8 }
|
|
|
|
wtWebGraphThermoBaroRSSChannelItemDescription OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Text of the RSS Feed."
|
|
::= { wtWebGraphThermoBaroRSS 9 }
|
|
|
|
wtWebGraphThermoBaroRSSChannelItemQuantity OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Number of lines."
|
|
::= { wtWebGraphThermoBaroRSS 10 }
|
|
|
|
-- wtWebGraphThermoBaroAlarm Group
|
|
----------------------------
|
|
|
|
wtWebGraphThermoBaroAlarmCount OBJECT-TYPE
|
|
SYNTAX INTEGER (1..8)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Number of independent alarms."
|
|
::= { wtWebGraphThermoBaroAlarm 1 }
|
|
|
|
-- Alarm Interface Table
|
|
|
|
wtWebGraphThermoBaroAlarmIfTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF WtWebGraphThermoBaroAlarmIfEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"List of alarm indices."
|
|
::= { wtWebGraphThermoBaroAlarm 2 }
|
|
|
|
wtWebGraphThermoBaroAlarmIfEntry OBJECT-TYPE
|
|
SYNTAX WtWebGraphThermoBaroAlarmIfEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Numbers of the alarms."
|
|
INDEX { wtWebGraphThermoBaroAlarmNo }
|
|
::= { wtWebGraphThermoBaroAlarmIfTable 1 }
|
|
|
|
WtWebGraphThermoBaroAlarmIfEntry ::= SEQUENCE {
|
|
wtWebGraphThermoBaroAlarmNo INTEGER
|
|
}
|
|
|
|
wtWebGraphThermoBaroAlarmNo OBJECT-TYPE
|
|
SYNTAX INTEGER (1..8)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Alarm number."
|
|
::= { wtWebGraphThermoBaroAlarmIfEntry 1 }
|
|
|
|
-- Alarm Table
|
|
|
|
wtWebGraphThermoBaroAlarmTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF WtWebGraphThermoBaroAlarmEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"List of settings depending on the alarm number."
|
|
::= { wtWebGraphThermoBaroAlarm 3 }
|
|
|
|
wtWebGraphThermoBaroAlarmEntry OBJECT-TYPE
|
|
SYNTAX WtWebGraphThermoBaroAlarmEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Alarm parameters of the individual alarms."
|
|
INDEX { wtWebGraphThermoBaroAlarmNo }
|
|
::= { wtWebGraphThermoBaroAlarmTable 1 }
|
|
|
|
WtWebGraphThermoBaroAlarmEntry ::= SEQUENCE {
|
|
wtWebGraphThermoBaroAlarmTrigger OCTET STRING,
|
|
wtWebGraphThermoBaroAlarmMin OCTET STRING,
|
|
wtWebGraphThermoBaroAlarmMax OCTET STRING,
|
|
wtWebGraphThermoBaroAlarmHysteresis OCTET STRING,
|
|
wtWebGraphThermoBaroAlarmDelay OCTET STRING,
|
|
wtWebGraphThermoBaroAlarmInterval OCTET STRING,
|
|
wtWebGraphThermoBaroAlarmEnable OCTET STRING,
|
|
wtWebGraphThermoBaroAlarmEMailAddr OCTET STRING,
|
|
wtWebGraphThermoBaroAlarmMailSubject OCTET STRING,
|
|
wtWebGraphThermoBaroAlarmMailText OCTET STRING,
|
|
wtWebGraphThermoBaroAlarmManagerIP OCTET STRING,
|
|
wtWebGraphThermoBaroAlarmTrapText OCTET STRING,
|
|
wtWebGraphThermoBaroAlarmMailOptions OCTET STRING,
|
|
wtWebGraphThermoBaroAlarmTcpIpAddr OCTET STRING,
|
|
wtWebGraphThermoBaroAlarmTcpPort INTEGER,
|
|
wtWebGraphThermoBaroAlarmTcpText OCTET STRING,
|
|
wtWebGraphThermoBaroAlarmClearMailSubject OCTET STRING,
|
|
wtWebGraphThermoBaroAlarmClearMailText OCTET STRING,
|
|
wtWebGraphThermoBaroAlarmClearTrapText OCTET STRING,
|
|
wtWebGraphThermoBaroAlarmClearTcpText OCTET STRING,
|
|
wtWebGraphThermoBaroAlarmDeltaTemp OCTET STRING,
|
|
wtWebGraphThermoBaroAlarmRHMin OCTET STRING,
|
|
wtWebGraphThermoBaroAlarmRHMax OCTET STRING,
|
|
wtWebGraphThermoBaroAlarmRHHysteresis OCTET STRING,
|
|
wtWebGraphThermoBaroAlarmAHMin OCTET STRING,
|
|
wtWebGraphThermoBaroAlarmAHMax OCTET STRING,
|
|
wtWebGraphThermoBaroAlarmSyslogIpAddr OCTET STRING,
|
|
wtWebGraphThermoBaroAlarmSyslogPort INTEGER,
|
|
wtWebGraphThermoBaroAlarmSyslogText OCTET STRING,
|
|
wtWebGraphThermoBaroAlarmSyslogClearText OCTET STRING,
|
|
wtWebGraphThermoBaroAlarmFtpDataPort OCTET STRING,
|
|
wtWebGraphThermoBaroAlarmFtpFileName OCTET STRING,
|
|
wtWebGraphThermoBaroAlarmFtpText OCTET STRING,
|
|
wtWebGraphThermoBaroAlarmFtpClearText OCTET STRING,
|
|
wtWebGraphThermoBaroAlarmFtpOption OCTET STRING,
|
|
wtWebGraphThermoBaroAlarmTimerCron OCTET STRING
|
|
}
|
|
|
|
wtWebGraphThermoBaroAlarmTrigger OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Binary coded trigger conditions:
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3:
|
|
Bit 0: Timer
|
|
Bit 1: ColdStart
|
|
Bit 2: WarmStart
|
|
|
|
Octet 4:
|
|
Bit 0: Sensor 1
|
|
Bit 1: Sensor 2
|
|
Bit 2-7: unused"
|
|
::= { wtWebGraphThermoBaroAlarmEntry 1 }
|
|
|
|
wtWebGraphThermoBaroAlarmMin OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Minimum temperature in degrees with maximum 2 decimal places."
|
|
::= { wtWebGraphThermoBaroAlarmEntry 2 }
|
|
|
|
wtWebGraphThermoBaroAlarmMax OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Maximum temperature in degrees with maximum 2 decimal places."
|
|
::= { wtWebGraphThermoBaroAlarmEntry 3 }
|
|
|
|
wtWebGraphThermoBaroAlarmHysteresis OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Temperature changes of this size clears the alarm state (MAX-hyst, MIN+hyst.)
|
|
, in degrees with maximum 2 decimal places."
|
|
::= { wtWebGraphThermoBaroAlarmEntry 4 }
|
|
|
|
wtWebGraphThermoBaroAlarmDelay OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Alarm will be delayed by setting this time while stable alarm
|
|
condition occur (time in minutes)."
|
|
::= { wtWebGraphThermoBaroAlarmEntry 5 }
|
|
|
|
|
|
wtWebGraphThermoBaroAlarmInterval OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Send interval for alarm messages."
|
|
::= { wtWebGraphThermoBaroAlarmEntry 6 }
|
|
|
|
wtWebGraphThermoBaroAlarmEnable OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Binary coded alarm enable:
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 0: Mail Enable
|
|
Bit 1: SNMP Trap enable
|
|
Bit 2: TCP Client enable"
|
|
::= { wtWebGraphThermoBaroAlarmEntry 7 }
|
|
|
|
wtWebGraphThermoBaroAlarmEMailAddr OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"E-Mail address for sending the alarm mail to."
|
|
::= { wtWebGraphThermoBaroAlarmEntry 8 }
|
|
|
|
wtWebGraphThermoBaroAlarmMailSubject OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Subject line for alarm mail."
|
|
::= { wtWebGraphThermoBaroAlarmEntry 9 }
|
|
|
|
wtWebGraphThermoBaroAlarmMailText OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Alarm mail text: <Tn> provides the current temperature; n = 1..8.
|
|
<Z> provides the current time."
|
|
::= { wtWebGraphThermoBaroAlarmEntry 10 }
|
|
|
|
wtWebGraphThermoBaroAlarmManagerIP OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Name or IP address of the SNMP Manager which accepts the trap."
|
|
::= { wtWebGraphThermoBaroAlarmEntry 11 }
|
|
|
|
wtWebGraphThermoBaroAlarmTrapText OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This text is sent in the trap body."
|
|
::= { wtWebGraphThermoBaroAlarmEntry 12 }
|
|
|
|
wtWebGraphThermoBaroAlarmMailOptions OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Binary coded options:
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 0 : Attach Thermo.csv Enable
|
|
Bit 1 : CSV-Data_since_last_report
|
|
Bit 2-7: unused"
|
|
::= { wtWebGraphThermoBaroAlarmEntry 13 }
|
|
|
|
wtWebGraphThermoBaroAlarmTcpIpAddr OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Name or IP address of the TCP server which accepts the trap."
|
|
::= { wtWebGraphThermoBaroAlarmEntry 14 }
|
|
|
|
wtWebGraphThermoBaroAlarmTcpPort OBJECT-TYPE
|
|
SYNTAX INTEGER (1..65535)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Port number of the TCP server which accepts the trap."
|
|
::= { wtWebGraphThermoBaroAlarmEntry 15 }
|
|
|
|
wtWebGraphThermoBaroAlarmTcpText OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This text is sent in the TCP trap body."
|
|
::= { wtWebGraphThermoBaroAlarmEntry 16 }
|
|
|
|
wtWebGraphThermoBaroAlarmClearMailSubject OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Subject line for alarm clear mail."
|
|
::= { wtWebGraphThermoBaroAlarmEntry 17 }
|
|
|
|
wtWebGraphThermoBaroAlarmClearMailText OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Alarm clear mail text: <Tn> provides the current temperature; n = 1..8.
|
|
<Z> provides the current time."
|
|
::= { wtWebGraphThermoBaroAlarmEntry 18 }
|
|
|
|
wtWebGraphThermoBaroAlarmClearTrapText OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This text is sent in the trap body."
|
|
::= { wtWebGraphThermoBaroAlarmEntry 19 }
|
|
|
|
wtWebGraphThermoBaroAlarmClearTcpText OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This text is sent in the TCP trap body."
|
|
::= { wtWebGraphThermoBaroAlarmEntry 20 }
|
|
|
|
wtWebGraphThermoBaroAlarmDeltaTemp OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Maximum rate of change degrees/min with maximum 2 decimal places.
|
|
Compared with the average of a period of 5 minutes."
|
|
::= { wtWebGraphThermoBaroAlarmEntry 21 }
|
|
|
|
wtWebGraphThermoBaroAlarmRHMin OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Minimum rel. Humidity in percent with maximum 2 decimal places."
|
|
::= { wtWebGraphThermoBaroAlarmEntry 22 }
|
|
|
|
wtWebGraphThermoBaroAlarmRHMax OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Maximum rel.Humidity in percent with maximum 2 decimal places."
|
|
::= { wtWebGraphThermoBaroAlarmEntry 23 }
|
|
|
|
wtWebGraphThermoBaroAlarmRHHysteresis OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Hysterese rel. Humidity in percent with maximum 2 decimal places."
|
|
::= { wtWebGraphThermoBaroAlarmEntry 24 }
|
|
|
|
wtWebGraphThermoBaroAlarmAHMin OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Minimum abs. Humidity in g/(m*m*m) with maximum 2 decimal places."
|
|
::= { wtWebGraphThermoBaroAlarmEntry 25 }
|
|
|
|
wtWebGraphThermoBaroAlarmAHMax OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Maximum abs. Humidity in g/(m*m*m) with maximum 2 decimal places."
|
|
::= { wtWebGraphThermoBaroAlarmEntry 26 }
|
|
|
|
wtWebGraphThermoBaroAlarmSyslogIpAddr OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"IP address of the syslog server to which the Webio device should send syslog messages."
|
|
::= { wtWebGraphThermoBaroAlarmEntry 27 }
|
|
|
|
wtWebGraphThermoBaroAlarmSyslogPort OBJECT-TYPE
|
|
SYNTAX INTEGER (1..65535)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Port number of the syslog server to which the Webio device should send syslog messages."
|
|
::= { wtWebGraphThermoBaroAlarmEntry 28 }
|
|
|
|
wtWebGraphThermoBaroAlarmSyslogText OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Every message starts with the priority key, a time stamp and the host ip address, according RFC3164.
|
|
This text appears in the following syslog message body."
|
|
::= { wtWebGraphThermoBaroAlarmEntry 29 }
|
|
|
|
wtWebGraphThermoBaroAlarmSyslogClearText OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Every message starts with the priority key, a time stamp and the host ip address, according RFC3164.
|
|
This text appears in the following syslog message body."
|
|
::= { wtWebGraphThermoBaroAlarmEntry 30 }
|
|
|
|
wtWebGraphThermoBaroAlarmFtpDataPort OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Local data port: 1..65535 or AUTO: the next free port will be assigned."
|
|
::= { wtWebGraphThermoBaroAlarmEntry 31 }
|
|
|
|
wtWebGraphThermoBaroAlarmFtpFileName OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Name of the file including path informations."
|
|
::= { wtWebGraphThermoBaroAlarmEntry 32 }
|
|
|
|
wtWebGraphThermoBaroAlarmFtpText OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Message text to store on the FTP server."
|
|
::= { wtWebGraphThermoBaroAlarmEntry 33 }
|
|
|
|
wtWebGraphThermoBaroAlarmFtpClearText OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Alarm clear message to store on the FTP server."
|
|
::= { wtWebGraphThermoBaroAlarmEntry 34 }
|
|
|
|
wtWebGraphThermoBaroAlarmFtpOptions OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Binary coded options, select only one option at the same time:
|
|
STORE = replace file
|
|
APPEND = append message at the end of the file
|
|
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 0 : STORE
|
|
Bit 1 : APPEND
|
|
Bit 2-7: unused"
|
|
::= { wtWebGraphThermoBaroAlarmEntry 35 }
|
|
|
|
wtWebGraphThermoBaroAlarmTimerCron OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This entry contains 5 space or tab seperated text fields for time trigger definition.
|
|
Each field must match with the actual time to trigger a message, weekday and day of month
|
|
are interpreted separatley.
|
|
1: Minutes Range 0-59
|
|
2. Hours Range 0-23, 0 is midnight
|
|
3: Day of month Range 1-31
|
|
4: Month Range 1-12
|
|
5: Weekday Range 0-6, 0 is sunday
|
|
|
|
Syntax for every field:
|
|
- an asterix (*) enables every possible setting of a field
|
|
- single numbers seperated by commas
|
|
- a partition within the allowed range (1-5)
|
|
- step size within an partition of the allowed range (0-59/2: every second minute)."
|
|
::= { wtWebGraphThermoBaroAlarmEntry 36 }
|
|
|
|
-- wtWebGraphThermoBaroGraphicsBase Group
|
|
----------------------------
|
|
|
|
wtWebGraphThermoBaroGraphicsBaseEnable OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Defines the viewing options of the graphic:
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 0 : Auto scroll enable
|
|
Bit 1 : Show table
|
|
Bit 2 : Show graph
|
|
Bit 3 : Show control buttons
|
|
Bit 4 : Show config menu
|
|
Bit 5-7: unused"
|
|
::= { wtWebGraphThermoBaroGraphicsBase 1 }
|
|
|
|
wtWebGraphThermoBaroGraphicsBaseWidth OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Defines the width of the graphic in pixels."
|
|
::= { wtWebGraphThermoBaroGraphicsBase 2 }
|
|
|
|
wtWebGraphThermoBaroGraphicsBaseHeight OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Defines the height of the graphic in pixels."
|
|
::= { wtWebGraphThermoBaroGraphicsBase 3 }
|
|
|
|
wtWebGraphThermoBaroGraphicsBaseFrameColor OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(3))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Frame color definition in RGB."
|
|
::= { wtWebGraphThermoBaroGraphicsBase 4 }
|
|
|
|
wtWebGraphThermoBaroGraphicsBaseBackgroundColor OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(3))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Background color definition in RGB."
|
|
::= { wtWebGraphThermoBaroGraphicsBase 5 }
|
|
|
|
wtWebGraphThermoBaroGraphicsBasePollingrate OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Defines the pollingrate in seconds,
|
|
which defines the refreshing intervall of the graphic."
|
|
::= { wtWebGraphThermoBaroGraphicsBase 6 }
|
|
|
|
-- wtWebGraphThermoBaroGraphicsSelect Group
|
|
----------------------------
|
|
|
|
wtWebGraphThermoBaroGraphicsSelectDisplaySensorSel OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Binary coded sensor selection:
|
|
only selected sensors will be shown in the graphical presentation:
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 0: Sensor 1
|
|
Bit 1: Sensor 2
|
|
Bit 2: Sensor 3
|
|
Bit 3-7: unused"
|
|
::= { wtWebGraphThermoBaroGraphicsSelect 1 }
|
|
|
|
wtWebGraphThermoBaroGraphicsSelectDisplayShowExtrem OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Binary coded sensor selection:
|
|
only selected sensors will be shown with minima and maxima:
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 0: Sensor 1
|
|
Bit 1: Sensor 2
|
|
Bit 2: Sensor 3
|
|
Bit 3-7: unused"
|
|
::= { wtWebGraphThermoBaroGraphicsSelect 2 }
|
|
|
|
-- Graph Sensor Color Table
|
|
|
|
wtWebGraphThermoBaroSensorColorTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF wtWebGraphThermoBaroSensorColorEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"List of sensor colors for the praphical presentation."
|
|
::= { wtWebGraphThermoBaroGraphicsSelect 3 }
|
|
|
|
wtWebGraphThermoBaroSensorColorEntry OBJECT-TYPE
|
|
SYNTAX wtWebGraphThermoBaroSensorColorEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Numbers of the sensors."
|
|
INDEX { wtWebGraphThermoBaroSensorNo }
|
|
::= { wtWebGraphThermoBaroSensorColorTable 1 }
|
|
|
|
WtWebGraphThermoBaroSensorColorEntry ::= SEQUENCE {
|
|
wtWebGraphThermoBaroGraphicsSensorColor OCTET STRING,
|
|
wtWebGraphThermoBaroGraphicsSelectScale OCTET STRING
|
|
}
|
|
|
|
wtWebGraphThermoBaroGraphicsSensorColor OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(3))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Color of the sensors at the praphical presention."
|
|
::= { wtWebGraphThermoBaroSensorColorEntry 1 }
|
|
|
|
wtWebGraphThermoBaroGraphicsSelectScale OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Assignes one of 4 scales to a sensor:
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 0 : Use Scale 1
|
|
Bit 1 : Use Scale 2
|
|
Bit 2 : Use Scale 3
|
|
Bit 3-7: unused"
|
|
::= { wtWebGraphThermoBaroSensorColorEntry 2 }
|
|
|
|
-- wtWebGraphThermoBaroGraphicsScale Group
|
|
----------------------------
|
|
|
|
wtWebGraphThermoBaroGraphicsScaleAutoScaleEnable OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Select the Auto Scale Mode:
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 0 : Scale 1 Auto scale enable
|
|
Bit 1 : Scale 2 Auto scale enable
|
|
Bit 2 : Scale 3 Auto scale enable
|
|
Bit 3-7: unused"
|
|
::= { wtWebGraphThermoBaroGraphicsScale 1 }
|
|
|
|
|
|
wtWebGraphThermoBaroGraphicsScaleAutoFitEnable OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Select the Auto Fit Mode::
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 0 : Scale 1 Auto fit enable
|
|
Bit 1 : Scale 2 Auto fit enable
|
|
Bit 2 : Scale 3 Auto fit enable
|
|
Bit 3-7: unused"
|
|
::= { wtWebGraphThermoBaroGraphicsScale 2 }
|
|
|
|
wtWebGraphThermoBaroGraphicsScale1Min OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Scale 1: Minimum."
|
|
::= { wtWebGraphThermoBaroGraphicsScale 3 }
|
|
|
|
wtWebGraphThermoBaroGraphicsScale2Min OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Scale 2: Minimum."
|
|
::= { wtWebGraphThermoBaroGraphicsScale 4 }
|
|
|
|
wtWebGraphThermoBaroGraphicsScale3Min OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Scale 3: Minimum."
|
|
::= { wtWebGraphThermoBaroGraphicsScale 5 }
|
|
|
|
wtWebGraphThermoBaroGraphicsScale4Min OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Scale 4: Minimum."
|
|
::= { wtWebGraphThermoBaroGraphicsScale 6 }
|
|
|
|
wtWebGraphThermoBaroGraphicsScale1Max OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Scale 1: Maximum."
|
|
::= { wtWebGraphThermoBaroGraphicsScale 7 }
|
|
|
|
wtWebGraphThermoBaroGraphicsScale2Max OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Scale 2: Maximum."
|
|
::= { wtWebGraphThermoBaroGraphicsScale 8 }
|
|
|
|
wtWebGraphThermoBaroGraphicsScale3Max OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Scale 3: Maximum."
|
|
::= { wtWebGraphThermoBaroGraphicsScale 9 }
|
|
|
|
wtWebGraphThermoBaroGraphicsScale4Max OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Scale 4: Maximum."
|
|
::= { wtWebGraphThermoBaroGraphicsScale 10 }
|
|
|
|
wtWebGraphThermoBaroGraphicsScale1Unit OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Scale 1: Unit."
|
|
::= { wtWebGraphThermoBaroGraphicsScale 11 }
|
|
|
|
wtWebGraphThermoBaroGraphicsScale2Unit OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Scale 2: Unit."
|
|
::= { wtWebGraphThermoBaroGraphicsScale 12 }
|
|
|
|
wtWebGraphThermoBaroGraphicsScale3Unit OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Scale 3: Unit."
|
|
::= { wtWebGraphThermoBaroGraphicsScale 13 }
|
|
|
|
wtWebGraphThermoBaroGraphicsScale4Unit OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Scale 4: Unit."
|
|
::= { wtWebGraphThermoBaroGraphicsScale 14 }
|
|
|
|
|
|
-- wtWebGraphThermoBaroPorts Group
|
|
----------------------------
|
|
|
|
-- Table
|
|
|
|
wtWebGraphThermoBaroPortTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF WtWebGraphThermoBaroPortEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"List of settings depending on the sensor number."
|
|
::= { wtWebGraphThermoBaroPorts 1 }
|
|
|
|
wtWebGraphThermoBaroPortEntry OBJECT-TYPE
|
|
SYNTAX WtWebGraphThermoBaroPortEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Sensor parameters for the individual sensors."
|
|
INDEX { wtWebGraphThermoBaroSensorNo }
|
|
::= { wtWebGraphThermoBaroPortTable 1 }
|
|
|
|
WtWebGraphThermoBaroPortEntry ::= SEQUENCE {
|
|
wtWebGraphThermoBaroPortName OCTET STRING,
|
|
wtWebGraphThermoBaroPortText OCTET STRING,
|
|
wtWebGraphThermoBaroPortOffset1 OCTET STRING,
|
|
wtWebGraphThermoBaroPortTemperature1 OCTET STRING,
|
|
wtWebGraphThermoBaroPortOffset2 OCTET STRING,
|
|
wtWebGraphThermoBaroPortTemperature2 OCTET STRING,
|
|
wtWebGraphThermoBaroPortComment OCTET STRING
|
|
}
|
|
|
|
wtWebGraphThermoBaroPortName OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Name of the sensor."
|
|
::= { wtWebGraphThermoBaroPortEntry 1 }
|
|
|
|
wtWebGraphThermoBaroPortText OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Description of the sensor."
|
|
::= { wtWebGraphThermoBaroPortEntry 2 }
|
|
|
|
wtWebGraphThermoBaroPortOffset1 OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Offset calibration: Offset in degrees with maximum 2 decimal places at temperature 1."
|
|
::= { wtWebGraphThermoBaroPortEntry 3 }
|
|
|
|
wtWebGraphThermoBaroPortTemperature1 OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Offset calibration: Reference temperature 1 in degrees with maximum 2 decimal places."
|
|
::= { wtWebGraphThermoBaroPortEntry 4 }
|
|
|
|
wtWebGraphThermoBaroPortOffset2 OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Offset calibration: Offset in degrees with maximum 2 decimal places at temperature 2."
|
|
::= { wtWebGraphThermoBaroPortEntry 5 }
|
|
|
|
wtWebGraphThermoBaroPortTemperature2 OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Offset calibration: Reference temperature 1 in degrees with maximum 2 decimal places."
|
|
::= { wtWebGraphThermoBaroPortEntry 6 }
|
|
|
|
wtWebGraphThermoBaroPortComment OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Offset calibration: informations of date, name of operator, reference devices."
|
|
::= { wtWebGraphThermoBaroPortEntry 7 }
|
|
|
|
wtWebGraphThermoBaroPortAltidude OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Altidude oh the Sensor over mean sea level (MSL)."
|
|
::= { wtWebGraphThermoBaroPorts 2 }
|
|
|
|
-- wtWebGraphThermoBaroManufact Group
|
|
----------------------------
|
|
|
|
wtWebGraphThermoBaroMfName OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Manufacturer company name"
|
|
::= { wtWebGraphThermoBaroManufact 1 }
|
|
|
|
wtWebGraphThermoBaroMfAddr OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Manufacturer address."
|
|
::= { wtWebGraphThermoBaroManufact 2 }
|
|
|
|
wtWebGraphThermoBaroMfHotline OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Manufacturer hotline."
|
|
::= { wtWebGraphThermoBaroManufact 3 }
|
|
|
|
wtWebGraphThermoBaroMfInternet OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Manufacturer Internet address."
|
|
::= { wtWebGraphThermoBaroManufact 4 }
|
|
|
|
wtWebGraphThermoBaroMfDeviceTyp OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Manufacturer device name (model number)."
|
|
::= { wtWebGraphThermoBaroManufact 5 }
|
|
|
|
wtWebGraphThermoBaroMfOrderNo OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Manufacturer part number."
|
|
::= { wtWebGraphThermoBaroManufact 6 }
|
|
|
|
-- wtWebGraphThermoBaroDiag Group
|
|
----------------------------
|
|
|
|
wtWebGraphThermoBaroDiagErrorCount OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Number of entries in the error memory."
|
|
::= { wtWebGraphThermoBaroDiag 1 }
|
|
|
|
wtWebGraphThermoBaroDiagBinaryError OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Error causes coded bit-by-bit."
|
|
::= { wtWebGraphThermoBaroDiag 2 }
|
|
|
|
wtWebGraphThermoBaroDiagErrorIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The value of this variable is used as an index to read
|
|
an error massege from wtWebGraphThermoBaroDiagErrorMessage.
|
|
Errors are numbered from 1 to wtWebGraphThermoBaroDiagErrorCount.
|
|
Writing a valid value into this variable, making the appropriate
|
|
message readable from wtWebGraphThermoBaroDiagErrorMessage."
|
|
::= { wtWebGraphThermoBaroDiag 3 }
|
|
|
|
wtWebGraphThermoBaroDiagErrorMessage OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Using wtWebGraphThermoBaroDiagErrorIndex as an index, the appropriate message is available."
|
|
::= { wtWebGraphThermoBaroDiag 4 }
|
|
|
|
wtWebGraphThermoBaroDiagErrorClear OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS write-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Writing 1 into this variable clears all diagnosis messages."
|
|
::= { wtWebGraphThermoBaroDiag 5 }
|
|
|
|
-- TRAP DEFINITIONS
|
|
|
|
-- Diese SNMP-Traps werden gesendet, wenn die Alarmtriggerbedingungen zutreffen
|
|
|
|
wtWebGraphThermoBaroAlert1 TRAP-TYPE
|
|
ENTERPRISE wtWebGraphThermoBaro
|
|
VARIABLES { wtWebGraphThermoBaroAlarmTrapText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 1 was triggered,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "Thermo-Hygrometer Alarm 1"
|
|
--#SUMMARY "Alarm 1: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 31
|
|
|
|
wtWebGraphThermoBaroAlert2 TRAP-TYPE
|
|
ENTERPRISE wtWebGraphThermoBaro
|
|
VARIABLES { wtWebGraphThermoBaroAlarmTrapText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 2 was triggered,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "Thermo-Hygrometer Alarm 2"
|
|
--#SUMMARY "Alarm 2: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 32
|
|
|
|
wtWebGraphThermoBaroAlert3 TRAP-TYPE
|
|
ENTERPRISE wtWebGraphThermoBaro
|
|
VARIABLES { wtWebGraphThermoBaroAlarmTrapText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 3 was triggered,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "Thermo-Hygrometer Alarm 3"
|
|
--#SUMMARY "Alarm 3: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 33
|
|
|
|
wtWebGraphThermoBaroAlert4 TRAP-TYPE
|
|
ENTERPRISE wtWebGraphThermoBaro
|
|
VARIABLES { wtWebGraphThermoBaroAlarmTrapText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 4 was triggered,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "Thermo-Hygrometer Alarm 4"
|
|
--#SUMMARY "Alarm 4: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 34
|
|
|
|
wtWebGraphThermoBaroAlert5 TRAP-TYPE
|
|
ENTERPRISE wtWebGraphThermoBaro
|
|
VARIABLES { wtWebGraphThermoBaroAlarmTrapText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 5 was triggered,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "Thermo-Hygrometer Alarm 5"
|
|
--#SUMMARY "Alarm 5: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 35
|
|
|
|
wtWebGraphThermoBaroAlert6 TRAP-TYPE
|
|
ENTERPRISE wtWebGraphThermoBaro
|
|
VARIABLES { wtWebGraphThermoBaroAlarmTrapText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 6 was triggered,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "Thermo-Hygrometer Alarm 6"
|
|
--#SUMMARY "Alarm 6: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 36
|
|
|
|
wtWebGraphThermoBaroAlert7 TRAP-TYPE
|
|
ENTERPRISE wtWebGraphThermoBaro
|
|
VARIABLES { wtWebGraphThermoBaroAlarmTrapText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 7 was triggered,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "Thermo-Hygrometer Alarm 7"
|
|
--#SUMMARY "Alarm 7: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 37
|
|
|
|
wtWebGraphThermoBaroAlert8 TRAP-TYPE
|
|
ENTERPRISE wtWebGraphThermoBaro
|
|
VARIABLES { wtWebGraphThermoBaroAlarmTrapText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 8 was triggered,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "Thermo-Hygrometer Alarm 8"
|
|
--#SUMMARY "Alarm 8: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 38
|
|
|
|
|
|
wtWebGraphThermoBaroAlert9 TRAP-TYPE
|
|
ENTERPRISE wtWebGraphThermoBaro
|
|
VARIABLES { wtWebGraphThermoBaroAlarmClearTrapText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 1 was cleared,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "Thermo-Hygrometer Release Alarm 1"
|
|
--#SUMMARY "Release Alarm 1: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 91
|
|
|
|
wtWebGraphThermoBaroAlert10 TRAP-TYPE
|
|
ENTERPRISE wtWebGraphThermoBaro
|
|
VARIABLES { wtWebGraphThermoBaroAlarmClearTrapText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 2 was cleared,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "Thermo-Hygrometer Release Alarm 2"
|
|
--#SUMMARY "Release Alarm 2: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 92
|
|
|
|
wtWebGraphThermoBaroAlert11 TRAP-TYPE
|
|
ENTERPRISE wtWebGraphThermoBaro
|
|
VARIABLES { wtWebGraphThermoBaroAlarmClearTrapText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 3 was cleared,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "Thermo-Hygrometer Release Alarm 3"
|
|
--#SUMMARY "Release Alarm 3: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 93
|
|
|
|
wtWebGraphThermoBaroAlert12 TRAP-TYPE
|
|
ENTERPRISE wtWebGraphThermoBaro
|
|
VARIABLES { wtWebGraphThermoBaroAlarmClearTrapText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 4 was cleared,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "Thermo-Hygrometer Release Alarm 4"
|
|
--#SUMMARY "Release Alarm 4: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 94
|
|
|
|
wtWebGraphThermoBaroAlert13 TRAP-TYPE
|
|
ENTERPRISE wtWebGraphThermoBaro
|
|
VARIABLES { wtWebGraphThermoBaroAlarmClearTrapText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 5 was cleared,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "Thermo-Hygrometer Release Alarm 5"
|
|
--#SUMMARY "Release Alarm 5: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 95
|
|
|
|
wtWebGraphThermoBaroAlert14 TRAP-TYPE
|
|
ENTERPRISE wtWebGraphThermoBaro
|
|
VARIABLES { wtWebGraphThermoBaroAlarmClearTrapText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 6 was cleared,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "Thermo-Hygrometer Release Alarm 6"
|
|
--#SUMMARY "Release Alarm 6: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 96
|
|
|
|
wtWebGraphThermoBaroAlert15 TRAP-TYPE
|
|
ENTERPRISE wtWebGraphThermoBaro
|
|
VARIABLES { wtWebGraphThermoBaroAlarmClearTrapText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 7 was cleared,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "Thermo-Hygrometer Release Alarm 7"
|
|
--#SUMMARY "Release Alarm 7: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 97
|
|
|
|
wtWebGraphThermoBaroAlert16 TRAP-TYPE
|
|
ENTERPRISE wtWebGraphThermoBaro
|
|
VARIABLES { wtWebGraphThermoBaroAlarmClearTrapText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 8 was cleared,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "Thermo-Hygrometer Release Alarm 8"
|
|
--#SUMMARY "Release Alarm 8: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 98
|
|
|
|
wtWebGraphThermoBaroAlertDiag TRAP-TYPE
|
|
ENTERPRISE wtWebGraphThermoBaro
|
|
VARIABLES {
|
|
wtWebGraphThermoBaroDiagErrorIndex,
|
|
wtWebGraphThermoBaroDiagErrorMessage
|
|
}
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when a diagnosis/error message was triggered,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "Thermo-Hygrometer Diagnose Error"
|
|
--#SUMMARY "Diagnose error index: %d, Message: %s."
|
|
--#ARGUMENTS {0,1}
|
|
--#SEVERITY MAJOR
|
|
--#TIMEINDEX 99
|
|
--#STATE DEGRADED
|
|
::= 110
|
|
|
|
END
|