-- Filename: epon-fault.mib
|
|
-- Description: Contains iSwitch MIB Extension.
|
|
-- MIB Version: 1.00
|
|
--
|
|
-- Copyright (C) 2001 by UTStarcom, Inc. All rights reserved.
|
|
-- Reproduction of this document is authorized on the condition that
|
|
-- the foregoing copyright notice is included.
|
|
--
|
|
-- NOTE: The contents of this document are subject to change without notice
|
|
-- *****************************************************************************
|
|
|
|
-- *****************************************************************************
|
|
-- Version: $Id: $
|
|
-- Last Modified: $DateTime: $
|
|
-- Change List #: $Change: $
|
|
-- *****************************************************************************
|
|
|
|
UTFAULT-MIB DEFINITIONS ::= BEGIN
|
|
|
|
IMPORTS
|
|
MODULE-IDENTITY,
|
|
NOTIFICATION-TYPE,
|
|
OBJECT-TYPE, IpAddress FROM SNMPv2-SMI
|
|
Counter, TimeTicks FROM RFC1155-SMI
|
|
RowStatus, TruthValue FROM SNMPv2-TC
|
|
ifIndex, DisplayString FROM RFC1213-MIB
|
|
MacAddress, BridgeId, Timeout FROM BRIDGE-MIB
|
|
uts-epon FROM UTS-EPON-MIB
|
|
utsDot3Security8021xRadiusSvrPrimaryOnuAuthIP FROM UTSECURITY-MIB
|
|
|
|
alarmModule,
|
|
alarmPort,
|
|
alarmLogicalPort,
|
|
alarmSeqNo,
|
|
alarmType,
|
|
alarmSeverity,
|
|
alarmErrorData,
|
|
alarmErrorDataStr,
|
|
alarmIgmpIIf,
|
|
alarmIgmpGrpAddr,
|
|
alarmIgmpOIf,
|
|
alarmIgmpProxyStatus,
|
|
alarmFanNumber,
|
|
alarmTaskName,
|
|
alarmResourceInt,
|
|
alarmDiagStatus,
|
|
alarmRdsSvrIp,
|
|
alarmPowerSlotStatus,
|
|
alarmPowerSlotNumber,
|
|
alarmRdsSvrIdx,
|
|
alarmSessionId,
|
|
alarmOpticalPower,
|
|
alarmOnuEtherPortIndex FROM EPONOAMINIT-ALARM-MIB
|
|
|
|
utAlarmSeqNo,
|
|
utAlarmOccurrenceTime,
|
|
utAlarmSeverity,
|
|
utAlarmProbableCause,
|
|
utAlarmType,
|
|
utAlarmClearType,
|
|
utAlarmResourceType FROM UTS-FAULT-MIB;
|
|
-- utsGeponBBS1000plus FROM UTS-BBS-COMMON-MIB;
|
|
|
|
|
|
|
|
utFault MODULE-IDENTITY
|
|
LAST-UPDATED "9407272253Z" -- Wed Jul 27 22:53:04 PDT 1994
|
|
ORGANIZATION "UTSTARcom Inc"
|
|
CONTACT-INFO
|
|
"Postal: UTSTARcom Inc
|
|
Alameda, California 9xxxx
|
|
Tel: +1 510 555 1212
|
|
E-Mail: mibs@utstar.com "
|
|
DESCRIPTION
|
|
"Contains UT EPON MIB Extensions."
|
|
::= { uts-epon 3 }
|
|
|
|
|
|
|
|
utsEponFaultExt OBJECT IDENTIFIER ::= { utFault 1 }
|
|
|
|
utsEponFaultExtObjects OBJECT IDENTIFIER ::= { utsEponFaultExt 1 }
|
|
|
|
utsEponNotifyExtObjects OBJECT IDENTIFIER ::= { utsEponFaultExt 2 }
|
|
|
|
|
|
|
|
--
|
|
-- 3. Fault
|
|
--
|
|
|
|
|
|
utsFaultTrapObjs OBJECT IDENTIFIER ::= { utsEponFaultExtObjects 1}
|
|
|
|
utsFaultAlarmObjs OBJECT IDENTIFIER ::= { utsEponFaultExtObjects 2 }
|
|
|
|
utsFaultThresholdObjs OBJECT IDENTIFIER ::= { utsEponFaultExtObjects 3 }
|
|
|
|
|
|
|
|
--
|
|
-- TRAP table
|
|
--
|
|
|
|
|
|
utsEponTrapTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF UtsEponTrapEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Table for epon trap configuration."
|
|
::= { utsFaultTrapObjs 1 }
|
|
|
|
utsEponTrapEntry OBJECT-TYPE
|
|
SYNTAX UtsEponTrapEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry in the Trap configuration table."
|
|
INDEX { utsEponTrapDestIP }
|
|
::= { utsEponTrapTable 1 }
|
|
|
|
UtsEponTrapEntry ::=
|
|
SEQUENCE {
|
|
|
|
utsEponTrapDestIP IpAddress,
|
|
utsEponTrapUDPPort INTEGER,
|
|
utsEponTrapCommunityString DisplayString,
|
|
utsEponTrapState RowStatus
|
|
|
|
}
|
|
|
|
|
|
|
|
utsEponTrapDestIP OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Trap destination IP configuration"
|
|
::= { utsEponTrapEntry 1 }
|
|
|
|
utsEponTrapUDPPort OBJECT-TYPE
|
|
SYNTAX INTEGER (1..65535)
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"SNMP trap udp port configuration, if it different from udp port 162(default)."
|
|
::= { utsEponTrapEntry 2 }
|
|
|
|
utsEponTrapCommunityString OBJECT-TYPE
|
|
SYNTAX DisplayString(SIZE(0..32))
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Encryption state."
|
|
::= { utsEponTrapEntry 3 }
|
|
|
|
utsEponTrapState OBJECT-TYPE
|
|
SYNTAX RowStatus
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Encryption direction."
|
|
::= { utsEponTrapEntry 4 }
|
|
|
|
|
|
|
|
|
|
-- ----
|
|
-- ---- Alarm table
|
|
-- ----
|
|
|
|
|
|
--utsEponAlarmTable OBJECT-TYPE
|
|
--SYNTAX SEQUENCE OF UtsEponAlarmEntry
|
|
-- MAX-ACCESS not-accessible
|
|
-- STATUS current
|
|
-- DESCRIPTION
|
|
--"Table for epon alarm severity configuration."
|
|
-- ::= { utsFaultAlarmObjs 1 }
|
|
--
|
|
--utsEponAlarmEntry OBJECT-TYPE
|
|
--SYNTAX UtsEponAlarmEntry
|
|
-- MAX-ACCESS not-accessible
|
|
-- STATUS current
|
|
-- DESCRIPTION
|
|
--"An entry in the Alarm configuration table."
|
|
-- INDEX { utsEponAlarmType }
|
|
-- ::= { utsEponAlarmTable 1 }
|
|
--
|
|
--UtsEponAlarmEntry ::=
|
|
-- SEQUENCE {
|
|
-- utsEponAlarmType INTEGER,
|
|
-- utsEponAlarmSeverity INTEGER
|
|
-- }
|
|
|
|
|
|
--utsEponAlarmType OBJECT-TYPE
|
|
--SYNTAX INTEGER {
|
|
-- radius-server-access-ok(1),
|
|
-- radius-server-not-accessible(2),
|
|
-- temperature-normal(3),
|
|
-- temperature-too-high(5),
|
|
-- fan-normal(6),
|
|
-- fan-abnormal(7),
|
|
-- cpu-resource-starvation(8),
|
|
-- memory-resource-starvation(9),
|
|
-- module-inserted(11),
|
|
-- module-removed(12),
|
|
-- module-diag-status(13),
|
|
-- chassis-power-sys-normal(15),
|
|
-- chassis-power-sys-abnormal(16),
|
|
-- chassis-power-module-event(17),
|
|
-- sfp-port-link-up(101),
|
|
-- sfp-port-link-down(102),
|
|
-- higig-port-link-up(103),
|
|
-- higig-port-link-down(104),
|
|
-- olt-up(201),
|
|
-- olt-down(202),
|
|
-- onu-up(301),
|
|
-- onu-down(302),
|
|
-- oam-802-dot3-link-fault-clear(304),
|
|
-- oam-802-dot3-link-fault(303),
|
|
-- oam-802-dot3-dying-gasp(305),
|
|
-- oam-802-dot3-critical-event-clear(308),
|
|
-- oam-802-dot3-critical-event(307),
|
|
-- igmp-proxy-status-down(402),
|
|
-- pon-bit-error-rate-alarm-clear(1004),
|
|
-- pon-bit-error-rate-alarm(1002),
|
|
-- pon-frame-error-rate-alarm-clear(1007),
|
|
-- pon-frame-error-rate-alarm(1005)
|
|
--}
|
|
-- MAX-ACCESS read-only
|
|
-- STATUS current
|
|
-- DESCRIPTION
|
|
--"Alarm type of EPON"
|
|
-- ::= { utsEponAlarmEntry 1 }
|
|
--
|
|
--utsEponAlarmSeverity OBJECT-TYPE
|
|
--SYNTAX INTEGER {
|
|
-- clear(0),
|
|
-- warning(1),
|
|
-- minor(2),
|
|
-- major(3),
|
|
-- critical(4),
|
|
-- indeterminate(5),
|
|
-- info(6),
|
|
-- filter(7)
|
|
--}
|
|
-- MAX-ACCESS read-write
|
|
-- STATUS current
|
|
-- DESCRIPTION
|
|
--"Alarm severity level for the specific alarm type."
|
|
-- ::= { utsEponAlarmEntry 2 }
|
|
|
|
|
|
|
|
|
|
------
|
|
------ Alarm Threshold table
|
|
------
|
|
|
|
|
|
utsEponAlarmThresholdTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF UtsEponAlarmThresholdEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Table for epon alarm threshold value configuration."
|
|
::= { utsFaultThresholdObjs 1 }
|
|
|
|
utsEponAlarmThresholdEntry OBJECT-TYPE
|
|
SYNTAX UtsEponAlarmThresholdEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry in the Alarm configuration table."
|
|
INDEX { utsEponAlarmThresholdIndex, utsEponAlarmThresholdType }
|
|
::= { utsEponAlarmThresholdTable 1 }
|
|
|
|
UtsEponAlarmThresholdEntry ::=
|
|
SEQUENCE {
|
|
utsEponAlarmThresholdIndex INTEGER,
|
|
utsEponAlarmThresholdType INTEGER,
|
|
utsEponAlarmThresholdSeverity INTEGER,
|
|
utsEponAlarmThresholdCurrent INTEGER,
|
|
utsEponAlarmThresholdMinValue INTEGER,
|
|
utsEponAlarmThresholdMaxValue INTEGER
|
|
}
|
|
|
|
utsEponAlarmThresholdIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Alarm threshold entry index."
|
|
::= { utsEponAlarmThresholdEntry 1 }
|
|
|
|
utsEponAlarmThresholdType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
llid-mismatch(1001),
|
|
onu-ber-alarm(1002),
|
|
onu-fer-alarm(1005)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Alarm type of EPON"
|
|
::= { utsEponAlarmThresholdEntry 2 }
|
|
|
|
utsEponAlarmThresholdSeverity OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
clear(0),
|
|
warning(1),
|
|
minor(2),
|
|
major(3),
|
|
critical(4),
|
|
indeterminate(5),
|
|
info(6),
|
|
filter(7)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Alarm severity level for the specific alarm type."
|
|
::= { utsEponAlarmThresholdEntry 3 }
|
|
|
|
|
|
utsEponAlarmThresholdCurrent OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Current Alarm threshold value for the specific alarm type."
|
|
::= { utsEponAlarmThresholdEntry 4 }
|
|
|
|
|
|
|
|
utsEponAlarmThresholdMinValue OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The minimal number of Alarm threshold value for the specific alarm type."
|
|
::= { utsEponAlarmThresholdEntry 5 }
|
|
|
|
|
|
utsEponAlarmThresholdMaxValue OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The above Alarm threshold value for the specific alarm type."
|
|
::= { utsEponAlarmThresholdEntry 6 }
|
|
|
|
|
|
|
|
------
|
|
------ OAM alarm threshold
|
|
------
|
|
|
|
|
|
utsEponOAMAlarmThresholdTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF UtsEponOAMAlarmThresholdEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Table for epon alarm threshold value configuration."
|
|
::= { utsFaultThresholdObjs 2 }
|
|
|
|
utsEponOAMAlarmThresholdEntry OBJECT-TYPE
|
|
SYNTAX UtsEponOAMAlarmThresholdEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry in the oam Alarm threshold configuration table."
|
|
INDEX { utsEponOAMAlarmThresholdIndex, utsEponOAMAlarmThresholdType }
|
|
::= { utsEponOAMAlarmThresholdTable 1 }
|
|
|
|
UtsEponOAMAlarmThresholdEntry ::=
|
|
SEQUENCE {
|
|
utsEponOAMAlarmThresholdIndex INTEGER,
|
|
utsEponOAMAlarmThresholdType INTEGER,
|
|
utsEponOAMAlarmThresholdSeverity INTEGER,
|
|
utsEponOAMAlarmThresholdCurrent INTEGER,
|
|
utsEponOAMAlarmThresholdWindow INTEGER,
|
|
utsEponOAMAlarmThresholdValue INTEGER,
|
|
utsEponOAMAlarmThresholdTotal INTEGER,
|
|
utsEponOAMAlarmEventTotal INTEGER
|
|
}
|
|
|
|
utsEponOAMAlarmThresholdIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"OAM Alarm threshold entry index."
|
|
::= { utsEponOAMAlarmThresholdEntry 1 }
|
|
|
|
utsEponOAMAlarmThresholdType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
err-symbol-period-alarm(2001),
|
|
err-frame-alarm(2002),
|
|
err-frame-period-alarm(2003)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"OAM Alarm type of EPON"
|
|
::= { utsEponOAMAlarmThresholdEntry 2 }
|
|
|
|
utsEponOAMAlarmThresholdSeverity OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
clear(0),
|
|
warning(1),
|
|
minor(2),
|
|
major(3),
|
|
critical(4),
|
|
indeterminate(5),
|
|
info(6),
|
|
filter(7)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"OAM Alarm severity level for the specific alarm type."
|
|
::= { utsEponOAMAlarmThresholdEntry 3 }
|
|
|
|
|
|
utsEponOAMAlarmThresholdCurrent OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"OAM Current Alarm threshold value for the specific alarm type."
|
|
::= { utsEponOAMAlarmThresholdEntry 4 }
|
|
|
|
|
|
|
|
utsEponOAMAlarmThresholdWindow OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"OAM Alarm threshold window value for the specific alarm type."
|
|
::= { utsEponOAMAlarmThresholdEntry 5 }
|
|
|
|
|
|
utsEponOAMAlarmThresholdValue OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"OAM Alarm threshold value for the specific alarm type."
|
|
::= { utsEponOAMAlarmThresholdEntry 6 }
|
|
|
|
|
|
utsEponOAMAlarmThresholdTotal OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"OAM total Alarm threshold value for the specific alarm type."
|
|
::= { utsEponOAMAlarmThresholdEntry 7 }
|
|
|
|
|
|
utsEponOAMAlarmEventTotal OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"OAM total Alarm event value for the specific alarm type."
|
|
::= { utsEponOAMAlarmThresholdEntry 8 }
|
|
|
|
|
|
|
|
|
|
------
|
|
------ Alarm notify
|
|
------
|
|
|
|
|
|
------ utsFaultAlarmNotifyObjs OBJECT IDENTIFIER ::= { utsEponNotifyExtObjects 1 }
|
|
|
|
|
|
--
|
|
-- EPON realted alarms
|
|
--
|
|
|
|
utsEponFaultAlarm OBJECT IDENTIFIER ::= { utFault 2 }
|
|
|
|
utsEponRadiusServerAccessOk NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
utAlarmSeqNo,
|
|
utAlarmOccurrenceTime,
|
|
utAlarmSeverity,
|
|
utAlarmProbableCause,
|
|
utAlarmType,
|
|
utAlarmClearType,
|
|
utAlarmResourceType,
|
|
utsDot3Security8021xRadiusSvrPrimaryOnuAuthIP,
|
|
alarmSessionId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Epon Radius server not accessible."
|
|
::= { utsEponFaultAlarm 0 1 }
|
|
|
|
utsEponRadiusServerNotAccessible NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
utAlarmSeqNo,
|
|
utAlarmOccurrenceTime,
|
|
utAlarmSeverity,
|
|
utAlarmProbableCause,
|
|
utAlarmType,
|
|
utAlarmClearType,
|
|
utAlarmResourceType,
|
|
utsDot3Security8021xRadiusSvrPrimaryOnuAuthIP,
|
|
alarmSessionId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Epon Radius server not accessible."
|
|
::= { utsEponFaultAlarm 0 2 }
|
|
|
|
|
|
utsEponTemperatureNormal NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
utAlarmSeqNo,
|
|
utAlarmOccurrenceTime,
|
|
utAlarmSeverity,
|
|
utAlarmProbableCause,
|
|
utAlarmType,
|
|
utAlarmClearType,
|
|
utAlarmResourceType,
|
|
alarmSessionId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Epon box temperature back to normal."
|
|
::= { utsEponFaultAlarm 0 3 }
|
|
|
|
|
|
utsEponTemperatureTooHigh NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
utAlarmSeqNo,
|
|
utAlarmOccurrenceTime,
|
|
utAlarmSeverity,
|
|
utAlarmProbableCause,
|
|
utAlarmType,
|
|
utAlarmClearType,
|
|
utAlarmResourceType,
|
|
alarmSessionId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Epon box temperature too low."
|
|
::= { utsEponFaultAlarm 0 5 }
|
|
|
|
|
|
utsEponFanNormal NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
utAlarmSeqNo,
|
|
utAlarmOccurrenceTime,
|
|
utAlarmSeverity,
|
|
utAlarmProbableCause,
|
|
utAlarmType,
|
|
utAlarmClearType,
|
|
utAlarmResourceType,
|
|
alarmFanNumber,
|
|
alarmSessionId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Epon fan start."
|
|
::= { utsEponFaultAlarm 0 6 }
|
|
|
|
|
|
utsEponFanAbnormal NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
utAlarmSeqNo,
|
|
utAlarmOccurrenceTime,
|
|
utAlarmSeverity,
|
|
utAlarmProbableCause,
|
|
utAlarmType,
|
|
utAlarmClearType,
|
|
utAlarmResourceType,
|
|
alarmFanNumber,
|
|
alarmSessionId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Epon fan stop."
|
|
::= { utsEponFaultAlarm 0 7 }
|
|
|
|
|
|
utsEponCPUUtil NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
utEventSeqNo,
|
|
utEventOccurrenceTime,
|
|
alarmTaskName,
|
|
alarmResourceInt
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Epon cpu resource util."
|
|
::= { utsEponFaultAlarm 0 8 }
|
|
|
|
utsEponMemResource NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
utEventSeqNo,
|
|
utEventOccurrenceTime,
|
|
alarmResourceInt
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Epon memory resource."
|
|
::= { utsEponFaultAlarm 0 9 }
|
|
|
|
|
|
|
|
utsEponModuleInsert NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
utAlarmSeqNo,
|
|
utAlarmOccurrenceTime,
|
|
utAlarmSeverity,
|
|
utAlarmProbableCause,
|
|
utAlarmType,
|
|
utAlarmClearType,
|
|
utAlarmResourceType,
|
|
alarmModule,
|
|
alarmSessionId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Epon module inserted. "
|
|
::= { utsEponFaultAlarm 0 11 }
|
|
|
|
|
|
utsEponModuleRemove NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
utAlarmSeqNo,
|
|
utAlarmOccurrenceTime,
|
|
utAlarmSeverity,
|
|
utAlarmProbableCause,
|
|
utAlarmType,
|
|
utAlarmClearType,
|
|
utAlarmResourceType,
|
|
alarmModule,
|
|
alarmSessionId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Epon module removed. "
|
|
::= { utsEponFaultAlarm 0 12 }
|
|
|
|
|
|
utsEponModuleDiag NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
utEventSeqNo,
|
|
utEventOccurrenceTime,
|
|
alarmDiagStatus
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Epon module diag status. "
|
|
::= { utsEponFaultAlarm 0 13 }
|
|
|
|
utsEponModuleSysPwrNormal NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
utAlarmSeqNo,
|
|
utAlarmOccurrenceTime,
|
|
utAlarmSeverity,
|
|
utAlarmProbableCause,
|
|
utAlarmType,
|
|
utAlarmClearType,
|
|
utAlarmResourceType,
|
|
alarmSessionId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Epon Chassis power supply recover "
|
|
::= { utsEponFaultAlarm 0 15 }
|
|
|
|
utsEponModuleSysPwrAbnormal NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
utAlarmSeqNo,
|
|
utAlarmOccurrenceTime,
|
|
utAlarmSeverity,
|
|
utAlarmProbableCause,
|
|
utAlarmType,
|
|
utAlarmClearType,
|
|
utAlarmResourceType,
|
|
alarmSessionId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Epon Chassis power supply recover "
|
|
::= { utsEponFaultAlarm 0 16 }
|
|
|
|
utsEponModPowerSlotEvent NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
utEventSeqNo,
|
|
utEventOccurrenceTime,
|
|
alarmPowerSlotNumber,
|
|
alarmPowerSlotStatus
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Epon Chassis power supply slot status "
|
|
::= { utsEponFaultAlarm 0 17 }
|
|
|
|
utsEponSFPLinkUp NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
utAlarmSeqNo,
|
|
utAlarmOccurrenceTime,
|
|
utAlarmSeverity,
|
|
utAlarmProbableCause,
|
|
utAlarmType,
|
|
utAlarmClearType,
|
|
utAlarmResourceType,
|
|
alarmModule,
|
|
alarmPort,
|
|
alarmSessionId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Epon sfp port link up. "
|
|
::= { utsEponFaultAlarm 0 101 }
|
|
|
|
utsEponSFPLinkDown NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
utAlarmSeqNo,
|
|
utAlarmOccurrenceTime,
|
|
utAlarmSeverity,
|
|
utAlarmProbableCause,
|
|
utAlarmType,
|
|
utAlarmClearType,
|
|
utAlarmResourceType,
|
|
alarmModule,
|
|
alarmPort,
|
|
alarmSessionId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Epon sfp port link down. "
|
|
::= { utsEponFaultAlarm 0 102 }
|
|
|
|
utsEponHigigLinkUp NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
utAlarmSeqNo,
|
|
utAlarmOccurrenceTime,
|
|
utAlarmSeverity,
|
|
utAlarmProbableCause,
|
|
utAlarmType,
|
|
utAlarmClearType,
|
|
utAlarmResourceType,
|
|
alarmSessionId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Epon higig port link up. "
|
|
::= { utsEponFaultAlarm 0 103 }
|
|
|
|
|
|
utsEponHigigLinkDown NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
utAlarmSeqNo,
|
|
utAlarmOccurrenceTime,
|
|
utAlarmSeverity,
|
|
utAlarmProbableCause,
|
|
utAlarmType,
|
|
utAlarmClearType,
|
|
utAlarmResourceType,
|
|
alarmSessionId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Epon higig port link down. "
|
|
::= { utsEponFaultAlarm 0 104 }
|
|
|
|
utsEponOltLinkUp NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
utAlarmSeqNo,
|
|
utAlarmOccurrenceTime,
|
|
utAlarmSeverity,
|
|
utAlarmProbableCause,
|
|
utAlarmType,
|
|
utAlarmClearType,
|
|
utAlarmResourceType,
|
|
alarmModule,
|
|
alarmPort,
|
|
alarmSessionId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Epon olt port link up. "
|
|
::= { utsEponFaultAlarm 0 201 }
|
|
|
|
utsEponOltLinkDown NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
utAlarmSeqNo,
|
|
utAlarmOccurrenceTime,
|
|
utAlarmSeverity,
|
|
utAlarmProbableCause,
|
|
utAlarmType,
|
|
utAlarmClearType,
|
|
utAlarmResourceType,
|
|
alarmModule,
|
|
alarmPort,
|
|
alarmSessionId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Epon olt port link down. "
|
|
::= { utsEponFaultAlarm 0 202 }
|
|
|
|
utsEponOnuLinkUp NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
utAlarmSeqNo,
|
|
utAlarmOccurrenceTime,
|
|
utAlarmSeverity,
|
|
utAlarmProbableCause,
|
|
utAlarmType,
|
|
utAlarmClearType,
|
|
utAlarmResourceType,
|
|
alarmModule,
|
|
alarmPort,
|
|
alarmLogicalPort,
|
|
alarmMacAddress,
|
|
alarmEponOnuHwType,
|
|
alarmSessionId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Epon onu port link up. "
|
|
::= { utsEponFaultAlarm 0 301 }
|
|
|
|
|
|
utsEponOnuLinkDown NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
utAlarmSeqNo,
|
|
utAlarmOccurrenceTime,
|
|
utAlarmSeverity,
|
|
utAlarmProbableCause,
|
|
utAlarmType,
|
|
utAlarmClearType,
|
|
utAlarmResourceType,
|
|
alarmModule,
|
|
alarmPort,
|
|
alarmLogicalPort,
|
|
alarmMacAddress,
|
|
alarmEponOnuHwType,
|
|
alarmSessionId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Epon onu port link down. "
|
|
::= { utsEponFaultAlarm 0 302 }
|
|
|
|
utsEponOnu802Dot3OamLinkFaultClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
utAlarmSeqNo,
|
|
utAlarmOccurrenceTime,
|
|
utAlarmSeverity,
|
|
utAlarmProbableCause,
|
|
utAlarmType,
|
|
utAlarmClearType,
|
|
utAlarmResourceType,
|
|
alarmModule,
|
|
alarmPort,
|
|
alarmLogicalPort,
|
|
alarmSessionId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Epon 802.3 oam link fault. "
|
|
::= { utsEponFaultAlarm 0 303 }
|
|
|
|
utsEponOnu802Dot3OamLinkFault NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
utAlarmSeqNo,
|
|
utAlarmOccurrenceTime,
|
|
utAlarmSeverity,
|
|
utAlarmProbableCause,
|
|
utAlarmType,
|
|
utAlarmClearType,
|
|
utAlarmResourceType,
|
|
alarmModule,
|
|
alarmPort,
|
|
alarmLogicalPort,
|
|
alarmSessionId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Epon 802.3 oam link fault. "
|
|
::= { utsEponFaultAlarm 0 304 }
|
|
|
|
utsEponOnuOam802Dot3DyingGasp NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
utEventSeqNo,
|
|
utEventOccurrenceTime,
|
|
alarmModule,
|
|
alarmPort,
|
|
alarmLogicalPort,
|
|
alarmMacAddress,
|
|
alarmEponOnuHwType
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Epon 802.3 oam dying gasp. "
|
|
::= { utsEponFaultAlarm 0 305 }
|
|
|
|
|
|
|
|
-- utsEponOnuOam802Dot3CriticalEventClear NOTIFICATION-TYPE
|
|
-- OBJECTS {
|
|
-- utEventSeqNo,
|
|
-- utEventOccurrenceTime,
|
|
-- alarmModule,
|
|
-- alarmPort,
|
|
-- alarmLogicalPort
|
|
-- }
|
|
-- STATUS current
|
|
-- DESCRIPTION
|
|
-- "Epon 802.3 oam critical event. "
|
|
-- ::= { utsEponFaultAlarm 0 307 }
|
|
|
|
-- utsEponOnuOam802Dot3CriticalEvent NOTIFICATION-TYPE
|
|
-- OBJECTS {
|
|
-- utEventSeqNo,
|
|
-- utEventOccurrenceTime,
|
|
-- alarmModule,
|
|
-- alarmPort,
|
|
-- alarmLogicalPort
|
|
-- }
|
|
-- STATUS current
|
|
-- DESCRIPTION
|
|
-- "Epon 802.3 oam critical event. "
|
|
-- ::= { utsEponFaultAlarm 0 308 }
|
|
|
|
utsEponOnuOam802Dot3CriticalAlarmClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
utAlarmSeqNo,
|
|
utAlarmOccurrenceTime,
|
|
utAlarmSeverity,
|
|
utAlarmProbableCause,
|
|
utAlarmType,
|
|
utAlarmClearType,
|
|
utAlarmResourceType,
|
|
alarmModule,
|
|
alarmPort,
|
|
alarmLogicalPort,
|
|
alarmSessionId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Epon 802.3 oam critical alarm. "
|
|
::= { utsEponFaultAlarm 0 311 }
|
|
|
|
|
|
utsEponOnuOam802Dot3CriticalAlarm NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
utAlarmSeqNo,
|
|
utAlarmOccurrenceTime,
|
|
utAlarmSeverity,
|
|
utAlarmProbableCause,
|
|
utAlarmType,
|
|
utAlarmClearType,
|
|
utAlarmResourceType,
|
|
alarmModule,
|
|
alarmPort,
|
|
alarmLogicalPort,
|
|
alarmSessionId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Epon 802.3 oam critical alarm. "
|
|
::= { utsEponFaultAlarm 0 312 }
|
|
|
|
utsEponIgmpProxyStatusDown NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
utEventSeqNo,
|
|
utEventOccurrenceTime,
|
|
alarmIgmpIIf,
|
|
alarmIgmpGrpAddr,
|
|
alarmIgmpOIf,
|
|
alarmIgmpProxyStatus
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Epon igmp proxy status down. "
|
|
::= { utsEponFaultAlarm 0 402 }
|
|
|
|
utsEponOnuSwitchOfflineClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
utAlarmSeqNo,
|
|
utAlarmOccurrenceTime,
|
|
utAlarmSeverity,
|
|
utAlarmProbableCause,
|
|
utAlarmType,
|
|
utAlarmClearType,
|
|
utAlarmResourceType,
|
|
alarmModule,
|
|
alarmPort,
|
|
alarmLogicalPort,
|
|
alarmSessionId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Epon ONU switch part off-line alarm clear. "
|
|
::= { utsEponFaultAlarm 0 1011 }
|
|
|
|
utsEponOnuSwitchOffline NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
utAlarmSeqNo,
|
|
utAlarmOccurrenceTime,
|
|
utAlarmSeverity,
|
|
utAlarmProbableCause,
|
|
utAlarmType,
|
|
utAlarmClearType,
|
|
utAlarmResourceType,
|
|
alarmModule,
|
|
alarmPort,
|
|
alarmLogicalPort,
|
|
alarmSessionId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Epon ONU swith part off-line alarm. "
|
|
::= { utsEponFaultAlarm 0 1013 }
|
|
|
|
-- zhaoxf added Dec 26 2005
|
|
|
|
utsEponOnuBerThresholdEvent NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
utEventSeqNo,
|
|
utEventOccurrenceTime,
|
|
alarmModule,
|
|
alarmPort,
|
|
alarmLogicalPort,
|
|
alarmPonLinkDirection,
|
|
alarmErrorData
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Epon ONU ber up link threshold reach event. "
|
|
::= { utsEponFaultAlarm 0 1014 }
|
|
|
|
utsEponOnuFerThresholdEvent NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
utEventSeqNo,
|
|
utEventOccurrenceTime,
|
|
alarmModule,
|
|
alarmPort,
|
|
alarmLogicalPort,
|
|
alarmPonLinkDirection,
|
|
alarmErrorData
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Epon ONU ber up link threshold reach event. "
|
|
::= { utsEponFaultAlarm 0 1015 }
|
|
|
|
utsEponDosAttackClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
utAlarmSeqNo,
|
|
utAlarmOccurrenceTime,
|
|
utAlarmSeverity,
|
|
utAlarmProbableCause,
|
|
utAlarmType,
|
|
utAlarmClearType,
|
|
utAlarmResourceType,
|
|
utAlarmAttackSource,
|
|
utAlarmAttackType,
|
|
alarmSessionId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Clear Alarm for Dos attack. "
|
|
::= { utsEponFaultAlarm 0 1016 }
|
|
|
|
utsEponDosAttack NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
utAlarmSeqNo,
|
|
utAlarmOccurrenceTime,
|
|
utAlarmSeverity,
|
|
utAlarmProbableCause,
|
|
utAlarmType,
|
|
utAlarmClearType,
|
|
utAlarmResourceType,
|
|
utAlarmAttackSource,
|
|
utAlarmAttackType,
|
|
alarmSessionId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Alarm for Dos attack. "
|
|
::= { utsEponFaultAlarm 0 1017 }
|
|
|
|
-- Feb 14, 2006; Obsolete the event type
|
|
-- CPU Utility Alarm
|
|
|
|
utsEponCPUUtilOverThresholdClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
utAlarmSeqNo,
|
|
utAlarmOccurrenceTime,
|
|
utAlarmSeverity,
|
|
utAlarmProbableCause,
|
|
utAlarmType,
|
|
utAlarmClearType,
|
|
utAlarmResourceType,
|
|
alarmTaskName,
|
|
alarmResourceInt,
|
|
alarmSessionId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Epon cpu resource util."
|
|
::= { utsEponFaultAlarm 0 1020 }
|
|
|
|
utsEponCPUUtilOverThreshold NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
utAlarmSeqNo,
|
|
utAlarmOccurrenceTime,
|
|
utAlarmSeverity,
|
|
utAlarmProbableCause,
|
|
utAlarmType,
|
|
utAlarmClearType,
|
|
utAlarmResourceType,
|
|
alarmTaskName,
|
|
alarmResourceInt,
|
|
alarmSessionId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Epon cpu resource util."
|
|
::= { utsEponFaultAlarm 0 1021 }
|
|
|
|
-- Memory Utility Alarm
|
|
|
|
utsEponMemResourceExhaustedClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
utAlarmSeqNo,
|
|
utAlarmOccurrenceTime,
|
|
utAlarmSeverity,
|
|
utAlarmProbableCause,
|
|
utAlarmType,
|
|
utAlarmClearType,
|
|
utAlarmResourceType,
|
|
alarmResourceInt,
|
|
alarmSessionId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Epon memory resource."
|
|
::= { utsEponFaultAlarm 0 1022 }
|
|
|
|
utsEponMemResourceExhausted NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
utAlarmSeqNo,
|
|
utAlarmOccurrenceTime,
|
|
utAlarmSeverity,
|
|
utAlarmProbableCause,
|
|
utAlarmType,
|
|
utAlarmClearType,
|
|
utAlarmResourceType,
|
|
alarmResourceInt,
|
|
alarmSessionId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Epon memory resource."
|
|
::= { utsEponFaultAlarm 0 1023 }
|
|
|
|
-- Zhaoxf Added Mar 5,2007
|
|
-- CTC EPON spec R1.3 requirments
|
|
|
|
-- ONU extension OAM discovery procedure error alam
|
|
|
|
utsEponOnuExtOamDiscErrorClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
utAlarmSeqNo,
|
|
utAlarmOccurrenceTime,
|
|
utAlarmSeverity,
|
|
utAlarmProbableCause,
|
|
utAlarmType,
|
|
utAlarmClearType,
|
|
utAlarmResourceType,
|
|
alarmModule,
|
|
alarmPort,
|
|
alarmLogicalPort,
|
|
utAlarmExtOamErrorType,
|
|
alarmSessionId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"ONU extension OAM discovery procedure error clear"
|
|
::= { utsEponFaultAlarm 0 1031 }
|
|
|
|
utsEponOnuExtOamDiscError NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
utAlarmSeqNo,
|
|
utAlarmOccurrenceTime,
|
|
utAlarmSeverity,
|
|
utAlarmProbableCause,
|
|
utAlarmType,
|
|
utAlarmClearType,
|
|
utAlarmResourceType,
|
|
alarmModule,
|
|
alarmPort,
|
|
alarmLogicalPort,
|
|
utAlarmExtOamErrorType,
|
|
alarmSessionId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"ONU extension OAM discovery procedure error"
|
|
::= { utsEponFaultAlarm 0 1032 }
|
|
|
|
-- ONU remote OAM response timeout alarm
|
|
|
|
utsEponOnuRemoteOamTimeoutClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
utAlarmSeqNo,
|
|
utAlarmOccurrenceTime,
|
|
utAlarmSeverity,
|
|
utAlarmProbableCause,
|
|
utAlarmType,
|
|
utAlarmClearType,
|
|
utAlarmResourceType,
|
|
alarmModule,
|
|
alarmPort,
|
|
alarmLogicalPort,
|
|
alarmSessionId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"ONU remote OAM response timeout alarm clear"
|
|
::= { utsEponFaultAlarm 0 1033 }
|
|
|
|
utsEponOnuRemoteOamTimeout NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
utAlarmSeqNo,
|
|
utAlarmOccurrenceTime,
|
|
utAlarmSeverity,
|
|
utAlarmProbableCause,
|
|
utAlarmType,
|
|
utAlarmClearType,
|
|
utAlarmResourceType,
|
|
alarmModule,
|
|
alarmPort,
|
|
alarmLogicalPort,
|
|
alarmSessionId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"ONU remote OAM response timeout alarm"
|
|
::= { utsEponFaultAlarm 0 1034 }
|
|
|
|
-- ONU invalid registration alarm, CTC spec R1.3 $11.4
|
|
|
|
utsEponOnuInvalidRegisterClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
utAlarmSeqNo,
|
|
utAlarmOccurrenceTime,
|
|
utAlarmSeverity,
|
|
utAlarmProbableCause,
|
|
utAlarmType,
|
|
utAlarmClearType,
|
|
utAlarmResourceType,
|
|
alarmModule,
|
|
alarmPort,
|
|
alarmLogicalPort,
|
|
alarmMacAddress,
|
|
alarmEponOnuHwType,
|
|
alarmSessionId
|
|
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"ONU invalid registeration alarm clear"
|
|
::= { utsEponFaultAlarm 0 1035 }
|
|
|
|
utsEponOnuInvalidRegister NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
utAlarmSeqNo,
|
|
utAlarmOccurrenceTime,
|
|
utAlarmSeverity,
|
|
utAlarmProbableCause,
|
|
utAlarmType,
|
|
utAlarmClearType,
|
|
utAlarmResourceType,
|
|
alarmModule,
|
|
alarmPort,
|
|
alarmLogicalPort,
|
|
alarmMacAddress,
|
|
alarmEponOnuHwType,
|
|
alarmSessionId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"ONU invalid registeration alarm"
|
|
::= { utsEponFaultAlarm 0 1036 }
|
|
|
|
-- ONU encryption key update timeout alarm, CTC spec R1.3 $11.1.2
|
|
|
|
utsEponOnuEncryptionKeyUpdateTimeoutClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
utAlarmSeqNo,
|
|
utAlarmOccurrenceTime,
|
|
utAlarmSeverity,
|
|
utAlarmProbableCause,
|
|
utAlarmType,
|
|
utAlarmClearType,
|
|
utAlarmResourceType,
|
|
alarmModule,
|
|
alarmPort,
|
|
alarmLogicalPort,
|
|
alarmSessionId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"ONU encryption key update timeout alarm clear"
|
|
::= { utsEponFaultAlarm 0 1037 }
|
|
|
|
utsEponOnuEncryptionKeyUpdateTimeout NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
utAlarmSeqNo,
|
|
utAlarmOccurrenceTime,
|
|
utAlarmSeverity,
|
|
utAlarmProbableCause,
|
|
utAlarmType,
|
|
utAlarmClearType,
|
|
utAlarmResourceType,
|
|
alarmModule,
|
|
alarmPort,
|
|
alarmLogicalPort,
|
|
alarmSessionId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"ONU encryption key update timeout alarm"
|
|
::= { utsEponFaultAlarm 0 1038 }
|
|
|
|
|
|
utsEponOnuByteErrorRateClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
utAlarmSeqNo,
|
|
utAlarmOccurrenceTime,
|
|
utAlarmSeverity,
|
|
utAlarmProbableCause,
|
|
utAlarmType,
|
|
utAlarmClearType,
|
|
utAlarmResourceType,
|
|
alarmModule,
|
|
alarmPort,
|
|
alarmLogicalPort,
|
|
alarmOnuByteErrorWindow,
|
|
alarmOnuByteErrorThresholdMin,
|
|
alarmSessionId
|
|
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"ONU byte error rate reach threshold alarm clear"
|
|
::= { utsEponFaultAlarm 0 1039 }
|
|
|
|
utsEponOnuByteErrorRate NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
utAlarmSeqNo,
|
|
utAlarmOccurrenceTime,
|
|
utAlarmSeverity,
|
|
utAlarmProbableCause,
|
|
utAlarmType,
|
|
utAlarmClearType,
|
|
utAlarmResourceType,
|
|
alarmModule,
|
|
alarmPort,
|
|
alarmLogicalPort,
|
|
alarmOnuByteErrorWindow,
|
|
alarmOnuByteErrorThresholdMin,
|
|
alarmSessionId
|
|
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"ONU byte error rate reach threshold alarm"
|
|
::= { utsEponFaultAlarm 0 1040 }
|
|
|
|
utsEponOnuRegisterEvent NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
utEventSeqNo,
|
|
utEventOccurrenceTime,
|
|
alarmModule,
|
|
alarmPort,
|
|
alarmLogicalPort,
|
|
alarmMacAddress,
|
|
alarmEponOnuHwType
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Epon ONU registered"
|
|
::= { utsEponFaultAlarm 0 1041 }
|
|
|
|
utsEponOnuDeregisterEvent NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
utEventSeqNo,
|
|
utEventOccurrenceTime,
|
|
alarmModule,
|
|
alarmPort,
|
|
alarmLogicalPort,
|
|
alarmMacAddress,
|
|
alarmEponOnuHwType
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Epon ONU deregistered"
|
|
::= { utsEponFaultAlarm 0 1042 }
|
|
|
|
utsEponOltCSMSwitchOver NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
utEventSeqNo,
|
|
utEventOccurrenceTime,
|
|
alarmModule
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Epon OLT CSM switch over take place"
|
|
::= { utsEponFaultAlarm 0 1043 }
|
|
|
|
|
|
utsEponConfigChangeEvent NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
utEventSeqNo,
|
|
utEventOccurrenceTime,
|
|
utEventConfigChange
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Epon ONU ber up link threshold reach event. "
|
|
::= { utsEponFaultAlarm 0 1200 }
|
|
|
|
utsEponOnuOam802Dot3DyingGaspAlarmClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
utAlarmSeqNo,
|
|
utAlarmOccurrenceTime,
|
|
utAlarmSeverity,
|
|
utAlarmProbableCause,
|
|
utAlarmType,
|
|
utAlarmClearType,
|
|
utAlarmResourceType,
|
|
alarmModule,
|
|
alarmPort,
|
|
alarmLogicalPort,
|
|
alarmMacAddress,
|
|
alarmEponOnuHwType,
|
|
alarmSessionId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"ONU Dying Gasp Alarm Clear"
|
|
::= { utsEponFaultAlarm 0 1224 }
|
|
|
|
utsEponOnuOam802Dot3DyingGaspAlarm NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
utAlarmSeqNo,
|
|
utAlarmOccurrenceTime,
|
|
utAlarmSeverity,
|
|
utAlarmProbableCause,
|
|
utAlarmType,
|
|
utAlarmClearType,
|
|
utAlarmResourceType,
|
|
alarmModule,
|
|
alarmPort,
|
|
alarmLogicalPort,
|
|
alarmMacAddress,
|
|
alarmEponOnuHwType,
|
|
alarmSessionId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"ONU Dying Gasp Alarm"
|
|
::= { utsEponFaultAlarm 0 1226 }
|
|
|
|
utsEponOnuReceiveSensitivityAlarmClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
utAlarmSeqNo,
|
|
utAlarmOccurrenceTime,
|
|
utAlarmSeverity,
|
|
utAlarmProbableCause,
|
|
utAlarmType,
|
|
utAlarmClearType,
|
|
utAlarmResourceType,
|
|
alarmModule,
|
|
alarmPort,
|
|
alarmLogicalPort,
|
|
alarmMacAddress,
|
|
alarmEponOnuHwType,
|
|
alarmOpticalPower,
|
|
alarmSessionId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"ONU Reveive Sensitivity Alarm Clear, read the value three times, if these values all good than the
|
|
system value, then send alarm clear."
|
|
::= { utsEponFaultAlarm 0 1228 }
|
|
|
|
utsEponOnuReceiveSensitivityAlarm NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
utAlarmSeqNo,
|
|
utAlarmOccurrenceTime,
|
|
utAlarmSeverity,
|
|
utAlarmProbableCause,
|
|
utAlarmType,
|
|
utAlarmClearType,
|
|
utAlarmResourceType,
|
|
alarmModule,
|
|
alarmPort,
|
|
alarmLogicalPort,
|
|
alarmMacAddress,
|
|
alarmEponOnuHwType,
|
|
alarmOpticalPower,
|
|
alarmSessionId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"ONU Reveive Sensitivity Alarm, read the value three times, if these values all bad than the system
|
|
value, then send alarm."
|
|
::= { utsEponFaultAlarm 0 1230 }
|
|
|
|
utsEponOnuOverloadOpticalPowerAlarmClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
utAlarmSeqNo,
|
|
utAlarmOccurrenceTime,
|
|
utAlarmSeverity,
|
|
utAlarmProbableCause,
|
|
utAlarmType,
|
|
utAlarmClearType,
|
|
utAlarmResourceType,
|
|
alarmModule,
|
|
alarmPort,
|
|
alarmLogicalPort,
|
|
alarmMacAddress,
|
|
alarmEponOnuHwType,
|
|
alarmOpticalPower,
|
|
alarmSessionId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"ONU Overload Optical Power Alarm Clear, read the value three times, if these values all good than the system
|
|
value, then send alarm clear."
|
|
::= { utsEponFaultAlarm 0 1232 }
|
|
|
|
utsEponOnuOverloadOpticalPowerAlarm NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
utAlarmSeqNo,
|
|
utAlarmOccurrenceTime,
|
|
utAlarmSeverity,
|
|
utAlarmProbableCause,
|
|
utAlarmType,
|
|
utAlarmClearType,
|
|
utAlarmResourceType,
|
|
alarmModule,
|
|
alarmPort,
|
|
alarmLogicalPort,
|
|
alarmMacAddress,
|
|
alarmEponOnuHwType,
|
|
alarmOpticalPower,
|
|
alarmSessionId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"ONU Overload Optical Power Alarm, read the value three times, if these values all bad than the system
|
|
value, then send alarm."
|
|
::= { utsEponFaultAlarm 0 1234 }
|
|
|
|
-- utsEponLoopbackDetectionEvent NOTIFICATION-TYPE
|
|
-- OBJECTS {
|
|
-- utEventSeqNo,
|
|
-- utEventOccurrenceTime,
|
|
-- alarmModule,
|
|
-- alarmPort,
|
|
-- alarmLogicalPort,
|
|
-- alarmMacAddress,
|
|
-- alarmEponOnuHwType
|
|
-- }
|
|
-- STATUS current
|
|
-- DESCRIPTION
|
|
-- "Epon ONU detect the loop."
|
|
-- ::= { utsEponFaultAlarm 0 1236 }
|
|
|
|
|
|
utsEponLoopbackDetectionAlarmClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
utAlarmSeqNo,
|
|
utAlarmOccurrenceTime,
|
|
utAlarmSeverity,
|
|
utAlarmProbableCause,
|
|
utAlarmType,
|
|
utAlarmClearType,
|
|
utAlarmResourceType,
|
|
alarmModule,
|
|
alarmPort,
|
|
alarmLogicalPort,
|
|
alarmMacAddress,
|
|
alarmEponOnuHwType,
|
|
alarmSessionId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"ONU Loopback detection Alarm Clear, if not dectect loopback in the continues 3 times, send the
|
|
alarm clear."
|
|
::= { utsEponFaultAlarm 0 1238 }
|
|
|
|
utsEponLoopbackDetectionAlarm NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
utAlarmSeqNo,
|
|
utAlarmOccurrenceTime,
|
|
utAlarmSeverity,
|
|
utAlarmProbableCause,
|
|
utAlarmType,
|
|
utAlarmClearType,
|
|
utAlarmResourceType,
|
|
alarmModule,
|
|
alarmPort,
|
|
alarmLogicalPort,
|
|
alarmMacAddress,
|
|
alarmEponOnuHwType,
|
|
alarmSessionId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"ONU Loopback detection Alarm, if dectect loopback in the continues 3 times, send the
|
|
alarm."
|
|
::= { utsEponFaultAlarm 0 1240 }
|
|
|
|
utsEponOnuEtherPortUp NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
utAlarmSeqNo,
|
|
utAlarmOccurrenceTime,
|
|
utAlarmSeverity,
|
|
utAlarmProbableCause,
|
|
utAlarmType,
|
|
utAlarmClearType,
|
|
utAlarmResourceType,
|
|
alarmModule,
|
|
alarmPort,
|
|
alarmLogicalPort,
|
|
alarmOnuEtherPortIndex,
|
|
alarmSessionId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"When the ONU Ether UNI is from down to up, send this trap."
|
|
::= { utsEponFaultAlarm 0 1250 }
|
|
|
|
utsEponOnuEtherPortDown NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
utAlarmSeqNo,
|
|
utAlarmOccurrenceTime,
|
|
utAlarmSeverity,
|
|
utAlarmProbableCause,
|
|
utAlarmType,
|
|
utAlarmClearType,
|
|
utAlarmResourceType,
|
|
alarmModule,
|
|
alarmPort,
|
|
alarmLogicalPort,
|
|
alarmOnuEtherPortIndex,
|
|
alarmSessionId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"When the ONU Ether UNI is from up to down, send this trap."
|
|
::= { utsEponFaultAlarm 0 1252 }
|
|
|
|
utsEponOltPonProtectionEvent NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
utEventSeqNo,
|
|
utEventOccurrenceTime,
|
|
alarmModule,
|
|
alarmPort
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Epon Olt Pon Protecton event, when use in trunk protection, the port is the switch over to port."
|
|
::= { utsEponFaultAlarm 0 1255 }
|
|
|
|
|
|
utsEponOltErroredFrameEvent NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
utEventSeqNo,
|
|
utEventOccurrenceTime,
|
|
alarmModule,
|
|
alarmPort
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Epon Olt Pon Errored Frame Event."
|
|
::= { utsEponFaultAlarm 0 1256 }
|
|
|
|
utsEponOnuErroredFrameEvent NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
utEventSeqNo,
|
|
utEventOccurrenceTime,
|
|
alarmModule,
|
|
alarmPort,
|
|
alarmLogicalPort
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Epon Onu Pon Errored Frame Event."
|
|
::= { utsEponFaultAlarm 0 1258 }
|
|
|
|
utsEponOnuRemoteOamTimeoutEvent NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
utEventSeqNo,
|
|
utEventOccurrenceTime,
|
|
alarmModule,
|
|
alarmPort,
|
|
alarmLogicalPort
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Epon Onu Remote Oam Timeout Event."
|
|
::= { utsEponFaultAlarm 0 1260 }
|
|
|
|
utsEponOnuOpticalTransceiverTempHighAlarmClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
utAlarmSeqNo,
|
|
utAlarmOccurrenceTime,
|
|
utAlarmSeverity,
|
|
utAlarmProbableCause,
|
|
utAlarmType,
|
|
utAlarmClearType,
|
|
utAlarmResourceType,
|
|
alarmModule,
|
|
alarmPort,
|
|
alarmLogicalPort,
|
|
alarmOnuOpticalTransceiverTemp,
|
|
alarmSessionId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The temp high of ONU transceiver alarm clear."
|
|
::= { utsEponFaultAlarm 0 1262 }
|
|
|
|
utsEponOnuOpticalTransceiverTempHighAlarm NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
utAlarmSeqNo,
|
|
utAlarmOccurrenceTime,
|
|
utAlarmSeverity,
|
|
utAlarmProbableCause,
|
|
utAlarmType,
|
|
utAlarmClearType,
|
|
utAlarmResourceType,
|
|
alarmModule,
|
|
alarmPort,
|
|
alarmLogicalPort,
|
|
alarmOnuOpticalTransceiverTemp,
|
|
alarmSessionId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The temp high of ONU transceiver alarm clear."
|
|
::= { utsEponFaultAlarm 0 1266 }
|
|
|
|
utsEponOnuOpticalTransceiverTempLowAlarmClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
utAlarmSeqNo,
|
|
utAlarmOccurrenceTime,
|
|
utAlarmSeverity,
|
|
utAlarmProbableCause,
|
|
utAlarmType,
|
|
utAlarmClearType,
|
|
utAlarmResourceType,
|
|
alarmModule,
|
|
alarmPort,
|
|
alarmLogicalPort,
|
|
alarmOnuOpticalTransceiverTemp,
|
|
alarmSessionId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The temp low of ONU transceiver alarm clear."
|
|
::= { utsEponFaultAlarm 0 1268 }
|
|
|
|
utsEponOnuOpticalTransceiverTempLowAlarm NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
utAlarmSeqNo,
|
|
utAlarmOccurrenceTime,
|
|
utAlarmSeverity,
|
|
utAlarmProbableCause,
|
|
utAlarmType,
|
|
utAlarmClearType,
|
|
utAlarmResourceType,
|
|
alarmModule,
|
|
alarmPort,
|
|
alarmLogicalPort,
|
|
alarmOnuOpticalTransceiverTemp,
|
|
alarmSessionId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The temp low of ONU transceiver alarm clear."
|
|
::= { utsEponFaultAlarm 0 1270 }
|
|
|
|
utsEponOnuOpticalTransceiverVccHighAlarmClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
utAlarmSeqNo,
|
|
utAlarmOccurrenceTime,
|
|
utAlarmSeverity,
|
|
utAlarmProbableCause,
|
|
utAlarmType,
|
|
utAlarmClearType,
|
|
utAlarmResourceType,
|
|
alarmModule,
|
|
alarmPort,
|
|
alarmLogicalPort,
|
|
alarmOnuOpticalTransceiverVcc,
|
|
alarmSessionId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The vcc high of ONU transceiver alarm clear."
|
|
::= { utsEponFaultAlarm 0 1272 }
|
|
|
|
utsEponOnuOpticalTransceiverVccHighAlarm NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
utAlarmSeqNo,
|
|
utAlarmOccurrenceTime,
|
|
utAlarmSeverity,
|
|
utAlarmProbableCause,
|
|
utAlarmType,
|
|
utAlarmClearType,
|
|
utAlarmResourceType,
|
|
alarmModule,
|
|
alarmPort,
|
|
alarmLogicalPort,
|
|
alarmOnuOpticalTransceiverVcc,
|
|
alarmSessionId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The vcc high of ONU transceiver alarm clear."
|
|
::= { utsEponFaultAlarm 0 1274 }
|
|
|
|
utsEponOnuOpticalTransceiverVccLowAlarmClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
utAlarmSeqNo,
|
|
utAlarmOccurrenceTime,
|
|
utAlarmSeverity,
|
|
utAlarmProbableCause,
|
|
utAlarmType,
|
|
utAlarmClearType,
|
|
utAlarmResourceType,
|
|
alarmModule,
|
|
alarmPort,
|
|
alarmLogicalPort,
|
|
alarmOnuOpticalTransceiverVcc,
|
|
alarmSessionId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The vcc low of ONU transceiver alarm clear."
|
|
::= { utsEponFaultAlarm 0 1276 }
|
|
|
|
utsEponOnuOpticalTransceiverVccLowAlarm NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
utAlarmSeqNo,
|
|
utAlarmOccurrenceTime,
|
|
utAlarmSeverity,
|
|
utAlarmProbableCause,
|
|
utAlarmType,
|
|
utAlarmClearType,
|
|
utAlarmResourceType,
|
|
alarmModule,
|
|
alarmPort,
|
|
alarmLogicalPort,
|
|
alarmOnuOpticalTransceiverVcc,
|
|
alarmSessionId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The vcc low of ONU transceiver alarm clear."
|
|
::= { utsEponFaultAlarm 0 1278 }
|
|
|
|
|
|
utsEponOnuOpticalTransceiverBiasHighAlarmClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
utAlarmSeqNo,
|
|
utAlarmOccurrenceTime,
|
|
utAlarmSeverity,
|
|
utAlarmProbableCause,
|
|
utAlarmType,
|
|
utAlarmClearType,
|
|
utAlarmResourceType,
|
|
alarmModule,
|
|
alarmPort,
|
|
alarmLogicalPort,
|
|
alarmOnuOpticalTransceiverBias,
|
|
alarmSessionId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The bias high of ONU transceiver alarm clear."
|
|
::= { utsEponFaultAlarm 0 1280 }
|
|
|
|
utsEponOnuOpticalTransceiverBiasHighAlarm NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
utAlarmSeqNo,
|
|
utAlarmOccurrenceTime,
|
|
utAlarmSeverity,
|
|
utAlarmProbableCause,
|
|
utAlarmType,
|
|
utAlarmClearType,
|
|
utAlarmResourceType,
|
|
alarmModule,
|
|
alarmPort,
|
|
alarmLogicalPort,
|
|
alarmOnuOpticalTransceiverBias,
|
|
alarmSessionId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The bias high of ONU transceiver alarm clear."
|
|
::= { utsEponFaultAlarm 0 1282 }
|
|
|
|
utsEponOnuOpticalTransceiverBiasLowAlarmClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
utAlarmSeqNo,
|
|
utAlarmOccurrenceTime,
|
|
utAlarmSeverity,
|
|
utAlarmProbableCause,
|
|
utAlarmType,
|
|
utAlarmClearType,
|
|
utAlarmResourceType,
|
|
alarmModule,
|
|
alarmPort,
|
|
alarmLogicalPort,
|
|
alarmOnuOpticalTransceiverBias,
|
|
alarmSessionId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The bias low of ONU transceiver alarm clear."
|
|
::= { utsEponFaultAlarm 0 1284 }
|
|
|
|
utsEponOnuOpticalTransceiverBiasLowAlarm NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
utAlarmSeqNo,
|
|
utAlarmOccurrenceTime,
|
|
utAlarmSeverity,
|
|
utAlarmProbableCause,
|
|
utAlarmType,
|
|
utAlarmClearType,
|
|
utAlarmResourceType,
|
|
alarmModule,
|
|
alarmPort,
|
|
alarmLogicalPort,
|
|
alarmOnuOpticalTransceiverBias,
|
|
alarmSessionId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The bias low of ONU transceiver alarm clear."
|
|
::= { utsEponFaultAlarm 0 1286 }
|
|
|
|
utsEponOnuOpticalTransceiverTxPowerHighAlarmClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
utAlarmSeqNo,
|
|
utAlarmOccurrenceTime,
|
|
utAlarmSeverity,
|
|
utAlarmProbableCause,
|
|
utAlarmType,
|
|
utAlarmClearType,
|
|
utAlarmResourceType,
|
|
alarmModule,
|
|
alarmPort,
|
|
alarmLogicalPort,
|
|
alarmOpticalPower,
|
|
alarmSessionId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The tx power high of ONU transceiver alarm clear."
|
|
::= { utsEponFaultAlarm 0 1288 }
|
|
|
|
utsEponOnuOpticalTransceiverTxPowerHighAlarm NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
utAlarmSeqNo,
|
|
utAlarmOccurrenceTime,
|
|
utAlarmSeverity,
|
|
utAlarmProbableCause,
|
|
utAlarmType,
|
|
utAlarmClearType,
|
|
utAlarmResourceType,
|
|
alarmModule,
|
|
alarmPort,
|
|
alarmLogicalPort,
|
|
alarmOpticalPower,
|
|
alarmSessionId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The tx power high of ONU transceiver alarm clear."
|
|
::= { utsEponFaultAlarm 0 1290 }
|
|
|
|
utsEponOnuOpticalTransceiverTxPowerLowAlarmClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
utAlarmSeqNo,
|
|
utAlarmOccurrenceTime,
|
|
utAlarmSeverity,
|
|
utAlarmProbableCause,
|
|
utAlarmType,
|
|
utAlarmClearType,
|
|
utAlarmResourceType,
|
|
alarmModule,
|
|
alarmPort,
|
|
alarmLogicalPort,
|
|
alarmOpticalPower,
|
|
alarmSessionId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The tx power low of ONU transceiver alarm clear."
|
|
::= { utsEponFaultAlarm 0 1292 }
|
|
|
|
utsEponOnuOpticalTransceiverTxPowerLowAlarm NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
utAlarmSeqNo,
|
|
utAlarmOccurrenceTime,
|
|
utAlarmSeverity,
|
|
utAlarmProbableCause,
|
|
utAlarmType,
|
|
utAlarmClearType,
|
|
utAlarmResourceType,
|
|
alarmModule,
|
|
alarmPort,
|
|
alarmLogicalPort,
|
|
alarmOpticalPower,
|
|
alarmSessionId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The tx power low of ONU transceiver alarm clear."
|
|
::= { utsEponFaultAlarm 0 1294 }
|
|
|
|
utsEponOnuOpticalTransceiverRxPowerHighAlarmClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
utAlarmSeqNo,
|
|
utAlarmOccurrenceTime,
|
|
utAlarmSeverity,
|
|
utAlarmProbableCause,
|
|
utAlarmType,
|
|
utAlarmClearType,
|
|
utAlarmResourceType,
|
|
alarmModule,
|
|
alarmPort,
|
|
alarmLogicalPort,
|
|
alarmOpticalPower,
|
|
alarmSessionId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The rx power high of ONU transceiver alarm clear."
|
|
::= { utsEponFaultAlarm 0 1296 }
|
|
|
|
utsEponOnuOpticalTransceiverRxPowerHighAlarm NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
utAlarmSeqNo,
|
|
utAlarmOccurrenceTime,
|
|
utAlarmSeverity,
|
|
utAlarmProbableCause,
|
|
utAlarmType,
|
|
utAlarmClearType,
|
|
utAlarmResourceType,
|
|
alarmModule,
|
|
alarmPort,
|
|
alarmLogicalPort,
|
|
alarmOpticalPower,
|
|
alarmSessionId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The rx power high of ONU transceiver alarm clear."
|
|
::= { utsEponFaultAlarm 0 1298 }
|
|
|
|
utsEponOnuOpticalTransceiverRxPowerLowAlarmClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
utAlarmSeqNo,
|
|
utAlarmOccurrenceTime,
|
|
utAlarmSeverity,
|
|
utAlarmProbableCause,
|
|
utAlarmType,
|
|
utAlarmClearType,
|
|
utAlarmResourceType,
|
|
alarmModule,
|
|
alarmPort,
|
|
alarmLogicalPort,
|
|
alarmOpticalPower,
|
|
alarmSessionId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The rx power low of ONU transceiver alarm clear."
|
|
::= { utsEponFaultAlarm 0 1300 }
|
|
|
|
utsEponOnuOpticalTransceiverRxPowerLowAlarm NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
utAlarmSeqNo,
|
|
utAlarmOccurrenceTime,
|
|
utAlarmSeverity,
|
|
utAlarmProbableCause,
|
|
utAlarmType,
|
|
utAlarmClearType,
|
|
utAlarmResourceType,
|
|
alarmModule,
|
|
alarmPort,
|
|
alarmLogicalPort,
|
|
alarmOpticalPower,
|
|
alarmSessionId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The rx power low of ONU transceiver alarm clear."
|
|
::= { utsEponFaultAlarm 0 1302 }
|
|
|
|
utsEponUplinkBandwidthBeyondEvent NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
utEventSeqNo,
|
|
utEventOccurrenceTime,
|
|
alarmModule,
|
|
alarmPort
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Epon Olt uplink bandwidth beyond the threshold Event."
|
|
::= { utsEponFaultAlarm 0 1500 }
|
|
|
|
utsEponOnuUniBandwidthBeyondEvent NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
utEventSeqNo,
|
|
utEventOccurrenceTime,
|
|
alarmModule,
|
|
alarmPort,
|
|
alarmLogicalPort,
|
|
alarmOnuEtherPortIndex
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Epon Onu uni bandwidth beyond Event."
|
|
::= { utsEponFaultAlarm 0 1502 }
|
|
|
|
|
|
END
|
|
|