175 lines
5.7 KiB
Plaintext
175 lines
5.7 KiB
Plaintext
-- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
|
|
--
|
|
-- Trend Micro, Inc.
|
|
-- Copyright information is in the DESCRIPTION section of the MODULE-IDENTITY.
|
|
--
|
|
-- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
|
|
|
|
TPT-SFLOW-MIB
|
|
|
|
DEFINITIONS ::= BEGIN
|
|
|
|
IMPORTS
|
|
MODULE-IDENTITY, OBJECT-TYPE, Unsigned32
|
|
FROM SNMPv2-SMI
|
|
|
|
TEXTUAL-CONVENTION
|
|
FROM SNMPv2-TC
|
|
|
|
tpt-tpa-objs
|
|
FROM TPT-TPAMIBS-MIB
|
|
|
|
;
|
|
|
|
tpt-sflow-objs MODULE-IDENTITY
|
|
LAST-UPDATED "201605251854Z" -- May 25, 2016
|
|
ORGANIZATION "Trend Micro, Inc."
|
|
CONTACT-INFO "www.trendmicro.com"
|
|
DESCRIPTION
|
|
"Global sFlow status and collector address/udp port on the device.
|
|
|
|
|
|
Copyright (C) 2016 Trend Micro Incorporated. All Rights Reserved.
|
|
|
|
Trend Micro makes no warranty of any kind with regard to this material,
|
|
including, but not limited to, the implied warranties of merchantability
|
|
and fitness for a particular purpose. Trend Micro shall not be liable for
|
|
errors contained herein or for incidental or consequential damages in
|
|
connection with the furnishing, performance, or use of this material. This
|
|
document contains proprietary information, which is protected by copyright. No
|
|
part of this document may be photocopied, reproduced, or translated into
|
|
another language without the prior written consent of Trend Micro. The
|
|
information is provided 'as is' without warranty of any kind and is subject to
|
|
change without notice. The only warranties for Trend Micro products and
|
|
services are set forth in the express warranty statements accompanying such
|
|
products and services. Nothing herein should be construed as constituting an
|
|
additional warranty. Trend Micro shall not be liable for technical or editorial
|
|
errors or omissions contained herein. TippingPoint(R), the TippingPoint logo, and
|
|
Digital Vaccine(R) are registered trademarks of Trend Micro. All other company
|
|
and product names may be trademarks of their respective holders. All rights
|
|
reserved. This document contains confidential information, trade secrets or
|
|
both, which are the property of Trend Micro. No part of this documentation may
|
|
be reproduced in any form or by any means or used to make any derivative work
|
|
(such as translation, transformation, or adaptation) without written permission
|
|
from Trend Micro or one of its subsidiaries. All other company and product
|
|
names may be trademarks of their respective holders.
|
|
"
|
|
|
|
REVISION "201605251854Z" -- May 25, 2016
|
|
DESCRIPTION "Updated copyright information. Minor MIB syntax fixes."
|
|
|
|
::= { tpt-tpa-objs 18 }
|
|
|
|
-- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
|
|
--
|
|
-- Textual conventions for slot MIB objects
|
|
--
|
|
-- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
|
|
|
|
SflowStatus ::= TEXTUAL-CONVENTION
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An indication of sFlow enable/disable/applicable status"
|
|
SYNTAX INTEGER { disable(0), enable(1), error(2), not-applicable(3) }
|
|
|
|
|
|
|
|
|
|
|
|
-- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
|
|
--
|
|
-- sFlow collector address and udp port number
|
|
--
|
|
-- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
|
|
|
|
sFlowCollectorTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF SflowCollectorEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Table of sFlow collectors. It supports up to 2 collectors."
|
|
::= { tpt-sflow-objs 1 }
|
|
|
|
sFlowCollectorEntry OBJECT-TYPE
|
|
SYNTAX SflowCollectorEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A collector address and port in the sFlowCollectorTable.
|
|
Rows cannot be created or deleted.
|
|
"
|
|
INDEX { collectorIndex }
|
|
::= { sFlowCollectorTable 1 }
|
|
|
|
SflowCollectorEntry ::= SEQUENCE {
|
|
collectorIndex Unsigned32,
|
|
collectorAddr OCTET STRING (SIZE (0..20)),
|
|
udpPort Unsigned32,
|
|
collectorAddrV6 OCTET STRING (SIZE (0..60))
|
|
}
|
|
|
|
collectorIndex OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Index into the sFlow collector table, starting with 1."
|
|
::= { sFlowCollectorEntry 1 }
|
|
|
|
collectorAddr OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (0..20))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The IPv4 address of the collector.
|
|
If the address is not set, the value will be an empty string.
|
|
It is not applicable on platforms (10/110/330).
|
|
For those platforms, the value will be set to an empty string.
|
|
|
|
"
|
|
::= {sFlowCollectorEntry 2 }
|
|
|
|
udpPort OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The udp port of the collector.
|
|
It is not applicable on Lowball platforms (10/110/330).
|
|
For those platforms, the value will be set to 0.
|
|
"
|
|
::= {sFlowCollectorEntry 3 }
|
|
|
|
collectorAddrV6 OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (0..60))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The IPv6 address of the collector.
|
|
If the address is not set, the value will be an empty string.
|
|
It is not applicable on Lowball platforms (10/110/330).
|
|
For those platforms, the value will be set to an empty string
|
|
"
|
|
::= { sFlowCollectorEntry 4 }
|
|
|
|
|
|
-- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
|
|
--
|
|
-- sFlow global enable/disable/applliacble flag
|
|
--
|
|
-- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
|
|
sFlowStatus OBJECT-TYPE
|
|
SYNTAX SflowStatus
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A Device-wide sFlow status."
|
|
::= { tpt-sflow-objs 2 }
|
|
|
|
|
|
|
|
|
|
END
|
|
|
|
|