TRANGO-P5M-MIB DEFINITIONS ::= BEGIN
|
|
|
|
IMPORTS
|
|
MODULE-IDENTITY,
|
|
OBJECT-TYPE,
|
|
OBJECT-IDENTITY,
|
|
Unsigned32,
|
|
NOTIFICATION-TYPE,
|
|
enterprises
|
|
FROM SNMPv2-SMI
|
|
|
|
NOTIFICATION-GROUP,
|
|
MODULE-COMPLIANCE
|
|
FROM SNMPv2-CONF;
|
|
|
|
-- islModules, islGeneric, islTrango
|
|
-- FROM ISL-GLOBAL-REG;
|
|
|
|
DisplayString ::= OCTET STRING
|
|
|
|
-- *******************************************************************
|
|
-- * Trango module
|
|
-- *******************************************************************
|
|
trango OBJECT IDENTIFIER ::= { enterprises 5454 }
|
|
tbw OBJECT IDENTIFIER ::= { trango 1 }
|
|
trangoModules OBJECT IDENTIFIER ::= { trango 10 }
|
|
|
|
trangoP5M MODULE-IDENTITY
|
|
LAST-UPDATED "200408270000Z"
|
|
ORGANIZATION "Trango Corporation"
|
|
CONTACT-INFO "
|
|
Name: Trango Systems, Inc.
|
|
Address: 15070 Avenue of Science
|
|
Zip: CA 92128
|
|
City: San Diego
|
|
Country: U.S.A.
|
|
Phone: +1-858-653-3900
|
|
e-mail: techsupport@trangobroadband.com
|
|
This is added by Eclips
|
|
"
|
|
DESCRIPTION "The Trango SNMP General MIB Module for Atlas Point to Point P5M"
|
|
REVISION "200408270000Z"
|
|
DESCRIPTION "Initial version."
|
|
::= { trangoModules 10 }
|
|
|
|
-- Trango Atlas Point to Point
|
|
|
|
p5m OBJECT IDENTIFIER ::= { tbw 40 }
|
|
|
|
-- *******************************************************************
|
|
-- ** System Information ** islTrango.p5m.sys
|
|
-- *******************************************************************
|
|
sys OBJECT IDENTIFIER ::= { p5m 1 }
|
|
|
|
-- **** Version **** islTrango.p5m.sys.1
|
|
|
|
ver OBJECT IDENTIFIER ::= { sys 1 }
|
|
|
|
verUintType OBJECT-TYPE
|
|
SYNTAX INTEGER { mu(1), ru(0) }
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "MU/RU"
|
|
::= { ver 1 }
|
|
|
|
verHW OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(2))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Hardware Version"
|
|
::= { ver 2 }
|
|
|
|
verFW OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..80))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Main firmware version <version code>H<hardware version>D<date code>"
|
|
::= { ver 3 }
|
|
|
|
-- verFWChecksum OBJECT-TYPE
|
|
-- SYNTAX OCTET STRING (SIZE(4))
|
|
-- MAX-ACCESS read-only
|
|
-- STATUS current
|
|
-- DESCRIPTION "Firmware Checksum"
|
|
-- ::= { ver 5 }
|
|
|
|
-- **** MAC Address **** islTrango.p5m.sys.2
|
|
|
|
sysMAC OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(6))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "MAC Address"
|
|
::= { sys 2 }
|
|
|
|
-- **** Default Opmode **** islTrango.p5m.sys.3
|
|
|
|
sysDefaultOpmode OBJECT-TYPE
|
|
SYNTAX INTEGER { on(1), off(0) }
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Default Opmode"
|
|
::= { sys 3 }
|
|
|
|
-- **** Current Opmode **** islTrango.p5m.sys.4
|
|
|
|
sysCurrentOpmode OBJECT-TYPE
|
|
SYNTAX INTEGER { on(1), off(0) }
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Current Opmode"
|
|
::= { sys 4 }
|
|
|
|
sysActivateOpmode OBJECT-TYPE
|
|
SYNTAX INTEGER { deactivated(0), activated(1) }
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Turn on opmode"
|
|
::= { sys 5 }
|
|
|
|
sysReadCommStr OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..32))
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "SNMP agent read community string. It is used for authentication purpose."
|
|
::= { sys 6 }
|
|
|
|
sysWriteCommStr OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..32))
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "SNMP agent write community string. It is used for authentication purpose."
|
|
::= { sys 7 }
|
|
|
|
-- **** Switches **** islTrango.p5m.sys.8
|
|
|
|
syssw OBJECT IDENTIFIER ::= { sys 8 }
|
|
|
|
sysswTftpServerEnable OBJECT-TYPE
|
|
SYNTAX INTEGER { disabled(0), enabled(1) }
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Enable or disable to receive code or fileset download."
|
|
::= { syssw 1 }
|
|
|
|
sysswAutoRateShiftingEnable OBJECT-TYPE
|
|
SYNTAX INTEGER { disabled(0), enabled(1) }
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Switch to different speed rate automatically
|
|
to get the maximum throughput value."
|
|
::= { syssw 2 }
|
|
|
|
sysswAutoScanMUSignal OBJECT-TYPE
|
|
SYNTAX INTEGER { disabled(0), enabled(1) }
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Remote unit scans to all channel frequencies
|
|
to listen to its master's heart-beat (RU Only)."
|
|
::= { syssw 3 }
|
|
|
|
sysswRSSILEDFlashEnable OBJECT-TYPE
|
|
SYNTAX INTEGER { disabled(0), enabled(1) }
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Enabling RSSI LED to blink based on its current RSSI value."
|
|
::= { syssw 4 }
|
|
|
|
sysswARQEnable OBJECT-TYPE
|
|
SYNTAX INTEGER { disabled(0), enabled(1) }
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "ARQ Enable (MU Only)"
|
|
::= { syssw 8 }
|
|
|
|
-- **** Traffic **** islTrango.p5m.sys.9
|
|
|
|
systraffic OBJECT IDENTIFIER ::= { sys 9 }
|
|
|
|
systrafficEthInOctets OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Number of payload octets received on Ethernet port."
|
|
::= { systraffic 1 }
|
|
|
|
systrafficEthOutOctets OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Number of payload octets transmitted on Ethernet port."
|
|
::= { systraffic 2 }
|
|
|
|
systrafficRfInOctets OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Number of octets of remote's payload received from RF port."
|
|
::= { systraffic 3 }
|
|
|
|
systrafficRfOutOctets OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Number of octets of remote's payload transmitted to RF port."
|
|
::= { systraffic 4 }
|
|
|
|
sysReserved1 OBJECT-TYPE
|
|
SYNTAX INTEGER { no(0), yes(1) }
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Save system setting values to Flash and activate the settings.
|
|
Not supported in this release."
|
|
DEFVAL { no }
|
|
::= { sys 11 }
|
|
|
|
sysReboot OBJECT-TYPE
|
|
SYNTAX INTEGER { deactivated(0), activated(1) }
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Reboot the master unit."
|
|
DEFVAL { deactivated }
|
|
::= { sys 12 }
|
|
|
|
-- **** IPConfig **** islTrango.p5m.sys.13
|
|
|
|
sysipconfig OBJECT IDENTIFIER ::= { sys 13 }
|
|
|
|
sysipconfigIpAddress OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
-- MAX-ACCESS read-only
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "IP address"
|
|
::= { sysipconfig 1 }
|
|
|
|
sysipconfigSubnet OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
-- MAX-ACCESS read-only
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Subnet mask"
|
|
::= { sysipconfig 2 }
|
|
|
|
sysipconfigDefaultGateway OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
-- MAX-ACCESS read-only
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Default gateway"
|
|
::= { sysipconfig 3 }
|
|
|
|
sysipconfigChange OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..80))
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "New IP Address, Subnet Mask and Default Gateway
|
|
xxx.xxx.xxx.xxx xxx.xxx.xxx.xxx xxx.xxx.xxx.xxx"
|
|
::= { sysipconfig 4 }
|
|
|
|
-- ************************************************************
|
|
sysRemarks OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..80))
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Remarks"
|
|
::= { sys 14 }
|
|
|
|
-- ************************************************************
|
|
sysEncryptEnable OBJECT-TYPE
|
|
SYNTAX INTEGER { disabled(0), enabled(1) }
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Enable/Disable Encrypt"
|
|
::= { sys 15 }
|
|
|
|
sysEncryptKey OBJECT-TYPE
|
|
SYNTAX Opaque (SIZE (16))
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Encrypt Key"
|
|
::= { sys 16 }
|
|
|
|
-- *******************************************************************
|
|
-- ** RF islTrango.p5m.rf
|
|
-- *******************************************************************
|
|
rf OBJECT IDENTIFIER ::= { p5m 2 }
|
|
|
|
rfPeerDeviceID OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(4))
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Device ID of Remote Unit"
|
|
::= { rf 1 }
|
|
|
|
rfActiveChannel OBJECT-TYPE
|
|
SYNTAX INTEGER (1..24)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "It specifies the current active channel number."
|
|
::= { rf 2 }
|
|
|
|
rfActivePolarization OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(1))
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "It specifies the current polarization."
|
|
::= { rf 3 }
|
|
|
|
rfSpeed OBJECT-TYPE
|
|
SYNTAX INTEGER (6 | 12 | 18 | 24 | 36 | 48 | 54)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "It specifies the rf speed."
|
|
::= { rf 4 }
|
|
|
|
rfTxPower OBJECT-TYPE
|
|
SYNTAX INTEGER (-30..40)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "It specifies tx power. And it will be limited by Min/Max by different band"
|
|
::= { rf 5 }
|
|
|
|
rfTxMIR OBJECT-TYPE
|
|
SYNTAX INTEGER (100..50000)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Max Tx Information Rate in Kbps"
|
|
::= { rf 6 }
|
|
|
|
rfNumberOfChannel OBJECT-TYPE
|
|
SYNTAX INTEGER (1..24)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "number of Channel"
|
|
::= { rf 7 }
|
|
|
|
-- **** Channel Table **** islTrango.p5m.rf.5
|
|
|
|
rfChannelTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF ChannelTableEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "Channel Table"
|
|
::= { rf 8 }
|
|
|
|
rfChannelTableEntry OBJECT-TYPE
|
|
SYNTAX ChannelTableEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "An entry of Channel Table."
|
|
INDEX { rfChannelTableIndex }
|
|
::= { rfChannelTable 1 }
|
|
|
|
ChannelTableEntry ::=
|
|
SEQUENCE {
|
|
rfChannelTableIndex INTEGER,
|
|
rfChannelFrequency INTEGER
|
|
}
|
|
|
|
rfChannelTableIndex OBJECT-TYPE
|
|
SYNTAX INTEGER (1..24)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "index of Channel Table"
|
|
::= { rfChannelTableEntry 1 }
|
|
|
|
rfChannelFrequency OBJECT-TYPE
|
|
SYNTAX INTEGER (5150..5875)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Frequency (MHz)"
|
|
::= { rfChannelTableEntry 2 }
|
|
|
|
-- *******************************************************************
|
|
-- *********************** Regulatory ********************************
|
|
-- *******************************************************************
|
|
|
|
rfAreaCode OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "area code which specify band regulatory"
|
|
::= { rf 9 }
|
|
|
|
-- *******************************************************************
|
|
|
|
rfBandTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF BandTableEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "4 Band Tables"
|
|
::= { rf 10 }
|
|
|
|
rfBandTableEntry OBJECT-TYPE
|
|
SYNTAX BandTableEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "An entry of Band Table."
|
|
INDEX { rfBandTableIndex }
|
|
::= { rfBandTable 1 }
|
|
|
|
BandTableEntry ::=
|
|
SEQUENCE {
|
|
rfBandTableIndex INTEGER,
|
|
rfBandRangeMin INTEGER,
|
|
rfBandRangeMax INTEGER,
|
|
rfBandEnable INTEGER,
|
|
rfBandTxPowerMin INTEGER,
|
|
rfBandTxPowerMaxCCK INTEGER,
|
|
rfBandTxPowerMaxBPSK INTEGER,
|
|
rfBandTxPowerMaxQPSK INTEGER,
|
|
rfBandTxPowerMax16QAM INTEGER,
|
|
rfBandTxPowerMax64QAM INTEGER
|
|
}
|
|
|
|
rfBandTableIndex OBJECT-TYPE
|
|
SYNTAX INTEGER (1..4)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "index of Band Table"
|
|
::= { rfBandTableEntry 1 }
|
|
|
|
rfBandRangeMin OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Min Frequency of Band"
|
|
::= { rfBandTableEntry 2 }
|
|
|
|
rfBandRangeMax OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Max Frequency of Band"
|
|
::= { rfBandTableEntry 3 }
|
|
|
|
rfBandEnable OBJECT-TYPE
|
|
SYNTAX INTEGER { disabled(0), enabled(1) }
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Band availability"
|
|
::= { rfBandTableEntry 4 }
|
|
|
|
rfBandTxPowerMin OBJECT-TYPE
|
|
SYNTAX INTEGER (-128..127)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Min Tx Power"
|
|
::= { rfBandTableEntry 5 }
|
|
|
|
rfBandTxPowerMaxCCK OBJECT-TYPE
|
|
SYNTAX INTEGER (-128..127)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Max Tx Power for CCK"
|
|
::= { rfBandTableEntry 6 }
|
|
|
|
rfBandTxPowerMaxBPSK OBJECT-TYPE
|
|
SYNTAX INTEGER (-128..127)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Max Tx Power for BPSK"
|
|
::= { rfBandTableEntry 7 }
|
|
|
|
rfBandTxPowerMaxQPSK OBJECT-TYPE
|
|
SYNTAX INTEGER (-128..127)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Max Tx Power for QPSK"
|
|
::= { rfBandTableEntry 8 }
|
|
|
|
rfBandTxPowerMax16QAM OBJECT-TYPE
|
|
SYNTAX INTEGER (-128..127)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Max Tx Power for 16 QAM"
|
|
::= { rfBandTableEntry 9 }
|
|
|
|
rfBandTxPowerMax64QAM OBJECT-TYPE
|
|
SYNTAX INTEGER (-128..127)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Max Tx Power for 64 QAM"
|
|
::= { rfBandTableEntry 10 }
|
|
|
|
-- *******************************************************************
|
|
|
|
rfRSSI OBJECT-TYPE
|
|
SYNTAX INTEGER (-128..127)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "RSSI (in dBm)."
|
|
::= { rf 12 }
|
|
|
|
rfAssociated OBJECT-TYPE
|
|
SYNTAX INTEGER { no(0), yes(1) }
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Association Status"
|
|
::= { rf 13 }
|
|
|
|
-- *******************************************************************
|
|
-- ** RU Management islTrango.p5m.ru (MU Only)
|
|
-- *******************************************************************
|
|
ru OBJECT IDENTIFIER ::= { p5m 3 }
|
|
|
|
ruReserved2 OBJECT-TYPE
|
|
SYNTAX INTEGER { deactivated(0), activated(1) }
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Perform Power Leveling RU. Not supported in this release."
|
|
::= { ru 1 }
|
|
|
|
ruReserved3 OBJECT-TYPE
|
|
SYNTAX INTEGER { deactivated(0), activated(1) }
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Reboot RU. Not supported in this release."
|
|
::= { ru 2 }
|
|
|
|
ruReserved4 OBJECT-TYPE
|
|
SYNTAX INTEGER ( 0..100 )
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Distance of RU in mile. Not supported in this release."
|
|
::= { ru 3 }
|
|
|
|
-- *******************************************************************
|
|
-- ** MU/RU Notifications
|
|
-- *******************************************************************
|
|
trap OBJECT IDENTIFIER ::= { p5m 4 }
|
|
maintenance OBJECT IDENTIFIER ::= { p5m 5 }
|
|
trangoEvents OBJECT IDENTIFIER ::= { p5m 6 }
|
|
trangoEventsV2 OBJECT IDENTIFIER ::= { trangoEvents 0 }
|
|
|
|
trapTrapDstTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF TrapTrapDstEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "This table allows control of the reporting of traps
|
|
generated by monitoring the operation of master or remote."
|
|
::= { trap 1 }
|
|
|
|
trapTrapDstEntry OBJECT-TYPE
|
|
SYNTAX TrapTrapDstEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "Allows configuration of the reporting mechanisms for a particular event."
|
|
INDEX { trapTrapDstIndex }
|
|
::= { trapTrapDstTable 1 }
|
|
|
|
TrapTrapDstEntry ::= SEQUENCE {
|
|
trapTrapDstIndex INTEGER,
|
|
trapTrapDstEnabling INTEGER
|
|
}
|
|
|
|
trapTrapDstIndex OBJECT-TYPE
|
|
SYNTAX INTEGER (1..2)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "Event Index."
|
|
::= { trapTrapDstEntry 1 }
|
|
|
|
trapTrapDstEnabling OBJECT-TYPE
|
|
SYNTAX INTEGER { disabled(0), enabled(1) }
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Enabled or Disabled sending trap."
|
|
::= { trapTrapDstEntry 2 }
|
|
|
|
trapTrapDstIpAddress OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "The IP Address of a management station to send traps to."
|
|
::= { trap 2 }
|
|
|
|
trapTrapCommStr OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..32))
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Trap community string."
|
|
::= { trap 3 }
|
|
|
|
maintenanceLinkControl OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (0..80))
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Link Test Summary Data."
|
|
::= { maintenance 1 }
|
|
|
|
maintenanceSiteSurveySummary1 OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (0..128))
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Site Survey Summary Data."
|
|
::= { maintenance 2 }
|
|
|
|
maintenanceServiceEnable OBJECT-TYPE
|
|
SYNTAX INTEGER { start(1), stop(2), changed(3), boareset(4) }
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Enable or disable system service."
|
|
::= { maintenance 3 }
|
|
|
|
maintenanceSiteSurveySummary2 OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (0..128))
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Site Survey Summary Data."
|
|
::= { maintenance 4 }
|
|
|
|
maintenanceSiteSurveySummary3 OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (0..128))
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Site Survey Summary Data."
|
|
::= { maintenance 5 }
|
|
|
|
maintenanceSiteSurveySummary4 OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (0..128))
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Site Survey Summary Data."
|
|
::= { maintenance 6 }
|
|
|
|
maintenanceSerialNumber OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Atlas Board Serial Number."
|
|
::= { maintenance 7 }
|
|
|
|
maintenanceUNIIMaxPower OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "UNII Maximum Power."
|
|
::= { maintenance 8 }
|
|
|
|
masterEvent NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
sysCurrentOpmode
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "This notification signifies that the master unit generated a report."
|
|
::= { trangoEventsV2 1 }
|
|
|
|
remoteEvent NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
-- TBD
|
|
sysCurrentOpmode
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "This notification signifies that the remote unit generated a report."
|
|
::= { trangoEventsV2 2 }
|
|
|
|
-- *******************************************************************
|
|
-- ** Groups and compliances
|
|
-- *******************************************************************
|
|
trangoConf OBJECT IDENTIFIER ::= { p5m 7 }
|
|
trangoGroups OBJECT IDENTIFIER ::= { trangoConf 1 }
|
|
trangoCompl OBJECT IDENTIFIER ::= { trangoConf 2 }
|
|
|
|
eventReportingGroupV2 NOTIFICATION-GROUP
|
|
NOTIFICATIONS {
|
|
masterEvent,
|
|
remoteEvent
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Notification group."
|
|
::= { trangoGroups 1 }
|
|
|
|
versionComplV2 MODULE-COMPLIANCE
|
|
STATUS current
|
|
DESCRIPTION "The implementation requirements for Trango products that support SNMP."
|
|
MODULE -- this module
|
|
MANDATORY-GROUPS {
|
|
eventReportingGroupV2
|
|
}
|
|
::= { trangoCompl 1 }
|
|
|
|
END
|
|
|