Observium_CE/mibs/supermicro/SUPERMICRO-MPLS-TP-MIB

308 lines
12 KiB
Plaintext

-- Copyright (C) 2008-2014 Super Micro Computer Inc. All Rights Reserved
-- $Id: fsmptp.mib,v 1.5 2012/09/07 09:52:05 siva Exp $
SUPERMICRO-MPLS-TP-MIB DEFINITIONS ::= BEGIN
IMPORTS
MODULE-IDENTITY, OBJECT-TYPE,
Unsigned32, enterprises
FROM SNMPv2-SMI -- [RFC2578]
TruthValue, RowStatus, DisplayString
FROM SNMPv2-TC; -- [RFC2579]
fsMplsTpMIB MODULE-IDENTITY
LAST-UPDATED "201209050000Z"
ORGANIZATION "Super Micro Computer Inc."
CONTACT-INFO "support@Supermicro.com"
DESCRIPTION "The Proprietary MIB for MPLS TP module"
REVISION "201209050000Z"
DESCRIPTION "The Proprietary MIB for MPLS TP module"
::= { enterprises supermicro-computer-inc(10876) super-switch(101) basic(1) futureMpls (13) 8}
-- Notifications
fsMplsTpNotifications OBJECT IDENTIFIER ::= { fsMplsTpMIB 0 }
-- MPLS Transport Profile objects
fsMplsTpObjects OBJECT IDENTIFIER ::= { fsMplsTpMIB 1 }
-- conformance
fsMplsTpConformance OBJECT IDENTIFIER ::= { fsMplsTpMIB 2 }
-- MPLS Transport Profile scalar objects
fsMplsTpScalarObjects OBJECT IDENTIFIER ::= { fsMplsTpObjects 1 }
-- Start of MPLS Transport Profile Global configuration table
fsMplsTpGlobalConfigTable OBJECT-TYPE
SYNTAX SEQUENCE OF FsMplsTpGlobalConfigEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table allows configurations that global for MPLS-TP
per virtual context. Configurations include global or operator
identifier, node identifier, ICC value and etc.,"
::= { fsMplsTpObjects 2 }
fsMplsTpGlobalConfigEntry OBJECT-TYPE
SYNTAX FsMplsTpGlobalConfigEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An Entry in this table represents per virtual context MPLS-TP
Global parameters. An entry in this table is created when a virtual
context is created."
INDEX { fsMplsTpContextId }
::= { fsMplsTpGlobalConfigTable 1 }
FsMplsTpGlobalConfigEntry ::= SEQUENCE {
fsMplsTpContextId Unsigned32,
fsMplsTpOamModuleStatus INTEGER,
fsMplsTpGlobalId Unsigned32,
fsMplsTpIcc DisplayString,
fsMplsTpNodeIdentifier Unsigned32,
fsMplsTpErrorCode INTEGER,
fsMplsTpTraceLevel Unsigned32,
fsMplsTpNotificationEnable TruthValue
}
fsMplsTpContextId OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A 32-bit unique identifier to identify the virtual context.
Currently, the implementation supports only the default virtual
context. Value of this object should always be set to zero."
::= { fsMplsTpGlobalConfigEntry 1 }
fsMplsTpOamModuleStatus OBJECT-TYPE
SYNTAX INTEGER {
enabled (1),
disabled (2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object allows the administrator to enable or disable MPLS-TP
OAM module."
DEFVAL { enabled }
::= { fsMplsTpGlobalConfigEntry 2 }
fsMplsTpGlobalId OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object allows the administrator to assign a unique operator
identifier also called MPLS-TP Global Identifier.
The Global Identifier can contain the 2-octet or 4-octet value
of the operator's Autonomous System Number (ASN).
Note: This object is not automatically derived from the ASN number.
The user has to configure this object explicitly. The value of this
object will be used as the default value for a service if the
operator fails to configure the Global ID for that service.A Global-Id
with 0 is the default value and is not a valid configuration for a
operationally active node."
REFERENCE
"MPLS-TP Identifiers draft version 02, Section 3.1"
DEFVAL { 0 }
::= { fsMplsTpGlobalConfigEntry 3 }
fsMplsTpIcc OBJECT-TYPE
SYNTAX DisplayString (SIZE (1..6))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object allows the operator or service provider to assign a
unique MPLS-TP ITU-T Carrier Code (ICC) to a network.
The ICC is a string of one to six characters, each character
being either alphabetic (i.e. A-Z) or numeric (i.e. 0-9)
characters. Alphabetic characters in the ICC should be
represented with upper case letters."
REFERENCE
"MPLS-TP Identifiers draft version 02, Section 3.2"
::= { fsMplsTpGlobalConfigEntry 4 }
fsMplsTpNodeIdentifier OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object allows the operator or service provider to assign a
unique MPLS-TP Node Identifier.
The Node Identifier is assigned within the scope of the Global
Identifier or Operator Identifier.
The value 0 (or 0.0.0.0 in dotted decimal notation) is reserved
and MUST NOT be used.
When IPv4 addresses are in use, the value of this object can be
derived from the LSR's /32 IPv4 loopback address.
Note that, when IP reachability is not needed, the 32-bit Node
Identifier is not required to have any association with the IPv4
address space.
Note: The value of this object has to be explicitly configured
by the user in both cases.A Node Id with 0 is the default
value and is not a valid configuration for a operationally
active node."
REFERENCE
"MPLS-TP Identifiers draft version 02, Section 4"
DEFVAL { 0 }
::= { fsMplsTpGlobalConfigEntry 5 }
fsMplsTpErrorCode OBJECT-TYPE
SYNTAX INTEGER {
elpsAssociationExists (1),
megAssociationExists (2),
pseudowireAssociationExists (3),
proactiveSessionExists (4),
elpsProactiveSessionExists (5),
activeMeExists(6)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object indicates the information about the latest error
that occurred when administrator is unable to set an object
in MPLS OAM Management database due to the presence of a
dependent information.
elpsAssociationExists (1) - Destroy of the lower layer application is not allowed
when the Enhanced Linear Protection Module
association exits.
megAssociationExists (2) - Destroy of the lower layer application is not allowed
when the MEG association exits.
pseudowireAssociationExists (3) - Destroy of the lower layer application is not allowed
when the pseudowire association exits.
proactiveSessionAssociationExists (4) - Destroy of the lower layer application is not allowed
when the proactive session association exits.
proactiveSessionAssociationExists (5) - Destroy of the lower layer application is not allowed
when there is proactive session and ELPS association exits.
activeMeExists(6) - Modifying MEG entry is not allowed, if there is an associated active ME
entry exists."
::= { fsMplsTpGlobalConfigEntry 6 }
fsMplsTpTraceLevel OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object is used to enable Trace Statements in
MPLS Module.
A FOUR BYTE integer is used for enabling the level of tracing.
Each BIT in the four byte integer, represents a particular
level of Trace.
The mapping between the bit positions & the level of trace is
as follows:
0x100000 - Function Entry or Exit Traces
0x010000 - Management Traces
0x001000 - Main Traces
0x000100 - Util Traces
0x000010 - Traces related to All Resources except Buffers
0x000001 - All Failure Traces
The remaining bits are unused. Combination of levels are
also allowed.
For example if the bits 0 and 1 are set, then the Trace
statements related to Init-Shutdown and management
will be printed.
The user has to enter the corresponding INTEGER VALUE for the
bits set. For example if bits 0 and 1 are set then user has to
set the value 3."
DEFVAL { 0 }
::= { fsMplsTpGlobalConfigEntry 7 }
fsMplsTpNotificationEnable OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"When this objects is true, then it enables the
generation of MEG DOWN, ME DOWN, MEG UP and ME UP
traps, otherwise these traps are not generated."
DEFVAL { false }
::= { fsMplsTpGlobalConfigEntry 8 }
-- End of MPLS Transport Profile Global configuration table
-- Start of MPLS Transport Profile Node Map table
fsMplsTpNodeMapTable OBJECT-TYPE
SYNTAX SEQUENCE OF FsMplsTpNodeMapEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table allows the administrator to map a node or LSR with an
operator or service provider. "
::= { fsMplsTpObjects 3 }
fsMplsTpNodeMapEntry OBJECT-TYPE
SYNTAX FsMplsTpNodeMapEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in this table represents a mapping identification for the
operator or service provider with node or LSR.
As per draft-ietf-mpls-tp-identifiers-02, this mapping is
represented as Global_ID::Node_ID.
Note: Each entry in this table should have a unique global ID and
Node ID combination."
INDEX { fsMplsTpContextId,
fsMplsTpNodeMapLocalNum }
::= { fsMplsTpNodeMapTable 1 }
FsMplsTpNodeMapEntry ::= SEQUENCE {
fsMplsTpNodeMapLocalNum Unsigned32,
fsMplsTpNodeMapGlobalId Unsigned32,
fsMplsTpNodeMapNodeId Unsigned32,
fsMplsTpNodeMapRowStatus RowStatus
}
fsMplsTpNodeMapLocalNum OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This object allows the administrator to assign a unique identifier to
map operator or global identifier and node identifier."
::= { fsMplsTpNodeMapEntry 1 }
fsMplsTpNodeMapGlobalId OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object Indicates the Global or Operator Identifier.
This object identifies an operator."
::= { fsMplsTpNodeMapEntry 2 }
fsMplsTpNodeMapNodeId OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object indicates the node identifier within the operator."
::= { fsMplsTpNodeMapEntry 3 }
fsMplsTpNodeMapRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This object allows the administrator to create, modify, and/or delete
a row in this table."
::= { fsMplsTpNodeMapEntry 4 }
-- End MPLS Transport Profile Node Map table