-- Copyright (C) 2008-2014 Super Micro Computer Inc. All Rights Reserved
|
|
|
|
--******************************************************************************
|
|
--$Id: fsdh6r.mib,v 1.9 2012/09/07 09:52:05 siva Exp $
|
|
--
|
|
--Description : This file contains MIB definitions for DHCPv6 Relay module.
|
|
--
|
|
--******************************************************************************/
|
|
|
|
SUPERMICRO-DHCPv6-RELAY-MIB DEFINITIONS ::= BEGIN
|
|
|
|
-- ******************************************************************
|
|
-- RFC-3736 Stateless DHCPv6 Relay MIB
|
|
-- ******************************************************************
|
|
|
|
IMPORTS
|
|
MODULE-IDENTITY,OBJECT-TYPE,
|
|
Counter32, Integer32,
|
|
enterprises,NOTIFICATION-TYPE FROM SNMPv2-SMI
|
|
RowStatus,DisplayString,
|
|
TruthValue FROM SNMPv2-TC
|
|
;
|
|
fsdhcpv6rly MODULE-IDENTITY
|
|
LAST-UPDATED "201209050000Z"
|
|
ORGANIZATION "Super Micro Computer Inc."
|
|
CONTACT-INFO "support@Supermicro.com"
|
|
DESCRIPTION
|
|
"This MIB is a proprietary MIB for Stateless-DHCPv6 relay
|
|
and conforms to RFC 3736(04/2004)."
|
|
REVISION "201209050000Z"
|
|
DESCRIPTION
|
|
"This MIB is a proprietary MIB for Stateless-DHCPv6 relay
|
|
and conforms to RFC 3736(04/2004)."
|
|
|
|
::= { enterprises supermicro-computer-inc(10876) super-switch(101) basic(2) 41 }
|
|
|
|
fsDhcp6RlyNotify OBJECT IDENTIFIER ::= { fsdhcpv6rly 0 }
|
|
fsDhcp6RlySystem OBJECT IDENTIFIER ::= { fsdhcpv6rly 1 }
|
|
fsDhcp6RlyConfig OBJECT IDENTIFIER ::= { fsdhcpv6rly 2 }
|
|
fsDhcp6RlyTraps OBJECT IDENTIFIER ::= { fsdhcpv6rly 3 }
|
|
-- ******************************************************************
|
|
-- Start the Scalars defination
|
|
-- ******************************************************************
|
|
fsDhcp6RlyDebugTrace OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(1..255))
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object stores the trace option string input given by the user.
|
|
Based on the input to this object, trace statements corresponding
|
|
to the given options are displayed. To enable particular
|
|
trace the user has to enter the corresponding string(given below)
|
|
assigned for that. For enabling more than one traces
|
|
the user has to enter the corresponding strings with
|
|
SPACE (delimiter) between each string.
|
|
For example,
|
|
To enable the below traces:
|
|
- Init and Shutdown traces
|
|
- Management traces
|
|
- Data path traces
|
|
- Control plane traces
|
|
- Packet Dump traces
|
|
The input should be fed as follows:
|
|
enable init-shut mgmt data ctrl pkt-dump
|
|
To disable the below traces:
|
|
- Init and Shutdown traces
|
|
- Data path traces
|
|
- Control plane traces
|
|
The input should be,disable init-shut data ctrl
|
|
The entered input string is parsed to get the trace
|
|
options.
|
|
enable - Enables the corresponding option.
|
|
disable - Disables the corresponding option.
|
|
init-shut - Init and Shutdown traces
|
|
mgmt - Management traces
|
|
ctrl - Control Plane traces
|
|
pkt-dump - Packet Dump traces
|
|
resource - Traces related to all
|
|
resources except buffers
|
|
all-fail - All Failure traces
|
|
buffer - Buffer allocation/
|
|
release traces
|
|
critical - Sl-DHCPv6 Relay Critical traces"
|
|
DEFVAL { "critical" }
|
|
::= { fsDhcp6RlySystem 1 }
|
|
|
|
fsDhcp6RlyTrapAdminControl OBJECT-TYPE
|
|
SYNTAX BITS{
|
|
none(0),
|
|
trapInvalidPacketIn(1),
|
|
trapMaxHopCount(2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The Object is used to enable or disable the transmission of
|
|
TRAP notification messages. A vector of Boolean notification types,
|
|
used to enable or disable the slDhcp6 notification types:
|
|
trapInvalidPacketIn (1)
|
|
trapMaxHopCount (2)
|
|
when Relay agent declares the received message as invalid then
|
|
the SNMP trap notification will come only when fsDhcp6RlyTrapAdminControl
|
|
is set with value 0.
|
|
when Relay agent receives the relay forward message with hop count
|
|
value is less then one configured hop count then SNMP trap
|
|
notification will come only when fsDhcp6RlyTrapAdminControl
|
|
is set with value trapInvalidPacketIn."
|
|
DEFVAL { "\0" }
|
|
::= { fsDhcp6RlySystem 2 }
|
|
|
|
fsDhcp6RlySysLogAdminStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
enabled (1),
|
|
disabled (2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This Object is used to enable or disable the transmission of
|
|
syslog notification messages.
|
|
DHCPv6 relay will generate the syslog messages only when
|
|
fsDhcp6RlySysLogAdminStatus is set as enabled (1).
|
|
|
|
disabled (2) means that DHCP server will not generate any
|
|
syslog messages."
|
|
DEFVAL { disabled }
|
|
::= { fsDhcp6RlySystem 3 }
|
|
|
|
fsDhcp6RlyListenPort OBJECT-TYPE
|
|
SYNTAX Integer32 (1..65535)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This Object is used to configure the port on which the
|
|
DHCPv6 relay agent will listen on. This is in order to facilitate
|
|
DHCPv6 relay to coexist with the DHCPv6 server which can listen on a
|
|
different port."
|
|
DEFVAL { 547 }
|
|
::= { fsDhcp6RlySystem 4 }
|
|
fsDhcp6RlyClientTransmitPort OBJECT-TYPE
|
|
SYNTAX Integer32 (1..65535)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This Object is used to configure the port on which the
|
|
DHCPv6 relay agent will send reply messages."
|
|
DEFVAL { 546 }
|
|
::= { fsDhcp6RlySystem 5 }
|
|
fsDhcp6RlyServerTransmitPort OBJECT-TYPE
|
|
SYNTAX Integer32 (1..65535)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This Object is used to configure the port on which the
|
|
DHCPv6 relay agent will send relay-forward messages."
|
|
DEFVAL { 547 }
|
|
::= { fsDhcp6RlySystem 6 }
|
|
fsDhcp6RlyOption37Control OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
enabled (1),
|
|
disabled (2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This Object is used to enable or disable the transmission of
|
|
Remote-id option along with Relay-fwd message.
|
|
DHCPv6 relay will insert remote-id with the relay-fwd message only when
|
|
fsDhcp6RlyOption37Control is set as enabled (1).
|
|
|
|
disabled (2) means that relay-fwd message will not be having remote-id
|
|
option along with."
|
|
DEFVAL { disabled }
|
|
::= { fsDhcp6RlySystem 7 }
|
|
|
|
-- ******************************************************************
|
|
-- Start of Relay Interface Table {fsDhcp6RlyIfTable)
|
|
-- ******************************************************************
|
|
|
|
fsDhcp6RlyIfTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF FsDhcp6RlyIfEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This table contains the statistics of SL-DHCPv6 Relay on each
|
|
interface. It will give the Number of Information Request, Relay
|
|
Forward, Relay reply messages received on the interface and
|
|
Number of Relay Reply, Relay Forward and Reply messages
|
|
transmitted from the interface.
|
|
This Table includes remote-id support to transmit remote-id value
|
|
within the Relay-fwd message from the interface."
|
|
::= { fsDhcp6RlyConfig 1 }
|
|
|
|
fsDhcp6RlyIfEntry OBJECT-TYPE
|
|
SYNTAX FsDhcp6RlyIfEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Entries of the fsDhcp6RlyIfTable"
|
|
INDEX {fsDhcp6RlyIfIndex}
|
|
::= { fsDhcp6RlyIfTable 1 }
|
|
|
|
FsDhcp6RlyIfEntry ::= SEQUENCE {
|
|
fsDhcp6RlyIfIndex Integer32,
|
|
fsDhcp6RlyIfHopThreshold Integer32,
|
|
fsDhcp6RlyIfInformIn Counter32,
|
|
fsDhcp6RlyIfRelayForwIn Counter32,
|
|
fsDhcp6RlyIfRelayReplyIn Counter32,
|
|
fsDhcp6RlyIfInvalidPktIn Counter32,
|
|
fsDhcp6RlyIfCounterRest TruthValue,
|
|
fsDhcp6RlyIfRowStatus RowStatus,
|
|
fsDhcp6RlyIfRemoteIdOption INTEGER,
|
|
fsDhcp6RlyIfRemoteIdDUID OCTET STRING,
|
|
fsDhcp6RlyIfRemoteIdOptionValue DisplayString,
|
|
fsDhcp6RlyIfRemoteIdUserDefined DisplayString
|
|
}
|
|
fsDhcp6RlyIfIndex OBJECT-TYPE
|
|
SYNTAX Integer32 (1..2147483647)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object identifies the unique Interface Index
|
|
value mapped to this Server Address Table.."
|
|
::= { fsDhcp6RlyIfEntry 1}
|
|
|
|
|
|
fsDhcp6RlyIfHopThreshold OBJECT-TYPE
|
|
SYNTAX Integer32 (0..32)
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A maximum hop count, a relay agent allow to pass through it. If
|
|
the HopCount in the DHCP Message is greater than the
|
|
fsDhcp6RlyHopsThreshold packet get dropped at the Relay Agent "
|
|
DEFVAL { 4 }
|
|
::= { fsDhcp6RlyIfEntry 3 }
|
|
|
|
fsDhcp6RlyIfInformIn OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object identifies the number of INFORMATION REQUEST messages
|
|
received on the Interface."
|
|
::= { fsDhcp6RlyIfEntry 4 }
|
|
|
|
fsDhcp6RlyIfRelayForwIn OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object identifies the number of RELAY FORWARD messages
|
|
received on the Interface."
|
|
::= { fsDhcp6RlyIfEntry 5 }
|
|
|
|
fsDhcp6RlyIfRelayReplyIn OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object identifies the number of RELAY REPLY messages
|
|
received on the Interface."
|
|
::= { fsDhcp6RlyIfEntry 6 }
|
|
|
|
|
|
|
|
|
|
fsDhcp6RlyIfInvalidPktIn OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object identifies the number of Invalid messages
|
|
received on the Interface."
|
|
::= { fsDhcp6RlyIfEntry 10 }
|
|
|
|
fsDhcp6RlyIfCounterRest OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object is used to reset all the statistics counter objects present
|
|
in this table. This will be done by setting the value of this column to
|
|
'true(1)'.
|
|
This column always reads back to 'false(2)'."
|
|
::= { fsDhcp6RlyIfEntry 11 }
|
|
|
|
fsDhcp6RlyIfRowStatus OBJECT-TYPE
|
|
SYNTAX RowStatus
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object is used to create/delete a row in the interface table.
|
|
when the interface is deleted from the system the corresponding
|
|
row from this table will also be deleted."
|
|
::= { fsDhcp6RlyIfEntry 12 }
|
|
|
|
fsDhcp6RlyIfRemoteIdOption OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
duid (1),
|
|
switchName (2),
|
|
mgmtIp (3),
|
|
userDefined (4)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object is used to specify which parameter has to be included
|
|
as remote-id in the outgoing relay-fwd message.
|
|
|
|
DUID (DHCP Unique Identifier) : If fsDhcp6RlyIfRemoteIdOption object
|
|
is set as 1, then dhcp unique identifier will be sent with the relay
|
|
forwarded message as remote-id. DUID can be configured by the use of
|
|
fsDhcp6RlyIfRemote-IdDUID object.
|
|
|
|
switchName : If fsDhcp6RlyIfRemoteIdOption object is set as 2, then
|
|
current system name (switch name) will be included as remote-id.
|
|
|
|
mgmtIp : If fsDhcp6RlyIfRemoteIdOption object is set as 3, then
|
|
remote-id will be set as the management IP of the system.
|
|
|
|
userDefined : If fsDhcp6RlyIfRemoteIdOption object is set as 4, then
|
|
administrative configured ascii value will be sent with the relay forwarded
|
|
message as remote-id. This fsDhcp6RlyIfRemoteIdUserDefined object can be used
|
|
to configure the user specific ascii value.
|
|
|
|
fsDhcp6RlyIfRemoteIdOption can be set only if fsDhcp6RlyOption37Control
|
|
is set as enable.In case fsDhcp6RlyOption37Control is disable then
|
|
fsDhcp6RlyIfRemoteIdOption will not be applicable."
|
|
DEFVAL { switchName }
|
|
::= { fsDhcp6RlyIfEntry 13 }
|
|
|
|
fsDhcp6RlyIfRemoteIdDUID OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (0..128))
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object is used to define the appropriate DUID for DHCPv6
|
|
Relay Agent.
|
|
|
|
Any communicating device (in dhcpv6 perspective) have a unique
|
|
DHCPv6 identifier (DUID). According to the RFC 4649, DHCPv6 servers
|
|
can use the DUID to make decisions about the information such as
|
|
addresses, delegated prefixes, configuration parameters etc. that
|
|
the client is to receive.
|
|
|
|
Relay Agent uses the DUID to have a unique remote-id for its enterprise
|
|
number, as sequence of enterprise number followed by remote-id must be
|
|
globally unique.
|
|
|
|
DHCPv6 Relay DUID is a user defined parameter so it can be set to any
|
|
value within defined boundaries.
|
|
DHCPv6 Relay DUID is a 128 octets long identifier, which can have
|
|
Link-Layer Address as DUID octets or can have Link-Layer address
|
|
along with some other parameter having variable octets or can have
|
|
any sequence of octets representing unique DUID.
|
|
|
|
This Object will be used only if value of fsDhcp6RlyIfRemoteIdOption object
|
|
is set as DUID (1)."
|
|
|
|
DEFVAL { ''h }
|
|
::= { fsDhcp6RlyIfEntry 14 }
|
|
|
|
fsDhcp6RlyIfRemoteIdOptionValue OBJECT-TYPE
|
|
SYNTAX DisplayString(SIZE(1..128))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object is used to get the current value of the remote-id option
|
|
(specified by fsDhcp6RlyIfRemoteIdOption object ), which is being used as
|
|
remote-id in dhcpv6 relay agent.
|
|
|
|
This object is covering all the three options (system name,
|
|
management ip, and duid value) although there is a specific object for
|
|
duid parameter."
|
|
|
|
::= { fsDhcp6RlyIfEntry 15 }
|
|
|
|
fsDhcp6RlyIfRemoteIdUserDefined OBJECT-TYPE
|
|
SYNTAX DisplayString(SIZE (0..128))
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object is used to configure the administrative specific unique ascii
|
|
value for DHCPv6 Relay Agent.
|
|
|
|
DHCPv6 servers can use this value to make decisions about the
|
|
information such as addresses, delegated prefixes, configuration parameters etc,
|
|
that the client is to receive.
|
|
|
|
Relay Agent uses this unique ascii value to have a unique remote-id for its
|
|
enterprise number, as sequence of enterprise number followed by remote-id must
|
|
be globally unique.
|
|
|
|
DHCPv6 Relay String is a user defined parameter so it can be set to any
|
|
value within defined boundaries.
|
|
DHCPv6 Relay ascii value is a 128 octets long identifier which can have any
|
|
administrative configured ascii value representing the unique string.
|
|
|
|
This Object will be used only if value of fsDhcp6RlyIfRemoteIdOption object
|
|
is set as userDefined (4)."
|
|
|
|
::= { fsDhcp6RlyIfEntry 16 }
|
|
|
|
|
|
-- ******************************************************************
|
|
-- End of Relay Interface Table {fsDhcp6RlyIfTable)
|
|
-- ******************************************************************
|
|
-- ******************************************************************
|
|
-- Start of Relay Server Address Table {fsDhcp6RlySrvAddressTable)
|
|
-- ******************************************************************
|
|
fsDhcp6RlySrvAddressTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF DhcpRelaySrvAddressEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This table contains the IP addresses of the DHCP Server
|
|
to which the Relay Agent needs to forward the packets from
|
|
the client or other relay agent . This object becomes
|
|
active only when fsDhcp6RlyServersOnly is enabled."
|
|
::= { fsDhcp6RlyConfig 2 }
|
|
|
|
fsDhcp6RlySrvAddressEntry OBJECT-TYPE
|
|
SYNTAX DhcpRelaySrvAddressEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The Address table entry. This entry is not lost
|
|
upon reboot. It is backed up by stable storage. Each entry
|
|
in this table contains the required attribute values which
|
|
define the Address Table Entry"
|
|
INDEX { fsDhcp6RlyInIfIndex, fsDhcp6RlySrvAddress }
|
|
::= { fsDhcp6RlySrvAddressTable 1 }
|
|
|
|
DhcpRelaySrvAddressEntry ::= SEQUENCE {
|
|
fsDhcp6RlyInIfIndex Integer32,
|
|
fsDhcp6RlySrvAddress OCTET STRING,
|
|
fsDhcp6RlySrvAddressRowStatus RowStatus
|
|
}
|
|
|
|
fsDhcp6RlyInIfIndex OBJECT-TYPE
|
|
SYNTAX Integer32 (1..2147483647)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object identifies the input Interface Index
|
|
value mapped to this Server Address Table.."
|
|
::= { fsDhcp6RlySrvAddressEntry 1}
|
|
|
|
fsDhcp6RlySrvAddress OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (16))
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The object indicates the IP Address of the DHCP server."
|
|
::= { fsDhcp6RlySrvAddressEntry 2 }
|
|
|
|
fsDhcp6RlySrvAddressRowStatus OBJECT-TYPE
|
|
SYNTAX RowStatus
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object is the status of the row "
|
|
::= { fsDhcp6RlySrvAddressEntry 3 }
|
|
|
|
-- ******************************************************************
|
|
-- End of Relay Server Address Table {fsDhcp6RlySrvAddressTable)
|
|
-- ******************************************************************
|
|
|
|
-- ******************************************************************
|
|
-- Start of Relay Output Interface Table {fsDhcp6RlyOutIfTable)
|
|
-- ******************************************************************
|
|
fsDhcp6RlyOutIfTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF Dhcp6RlyOutIfEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This table contains interface that specifies output interface for a
|
|
destination. If this argument is configured, client messages are
|
|
forwarded to the destination address through the link to which the
|
|
output interface is connected."
|
|
::= { fsDhcp6RlyConfig 3 }
|
|
|
|
fsDhcp6RlyOutIfEntry OBJECT-TYPE
|
|
SYNTAX Dhcp6RlyOutIfEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The output interface table entry. This entry is not lost
|
|
upon reboot. It is backed up by stable storage. Each entry
|
|
in this table contains the required attribute values which
|
|
define the output interface Table Entry"
|
|
INDEX { fsDhcp6RlyInIfIndex, fsDhcp6RlySrvAddress, fsDhcp6RlyOutIfIndex}
|
|
::= { fsDhcp6RlyOutIfTable 1 }
|
|
|
|
Dhcp6RlyOutIfEntry ::= SEQUENCE {
|
|
fsDhcp6RlyOutIfIndex Integer32,
|
|
fsDhcp6RlyOutIfRowStatus RowStatus
|
|
}
|
|
|
|
fsDhcp6RlyOutIfIndex OBJECT-TYPE
|
|
SYNTAX Integer32 (1..2147483647)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object identifies the output Interface Index
|
|
value mapped to this Server Address Table.."
|
|
::= { fsDhcp6RlyOutIfEntry 1}
|
|
|
|
fsDhcp6RlyOutIfRowStatus OBJECT-TYPE
|
|
SYNTAX RowStatus
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object is the status of the row "
|
|
::= { fsDhcp6RlyOutIfEntry 2 }
|
|
|
|
-- ******************************************************************
|
|
-- End of Relay Server Address Table {fsDhcp6RlySrvAddressTable)
|
|
-- ******************************************************************
|
|
|
|
-- ******************************************************************
|
|
-- TRAPS
|
|
-- ******************************************************************
|
|
fsDhcp6RlyTrapIfIndex OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object specifies the interface on which the trap is
|
|
was triggered."
|
|
::= { fsDhcp6RlyTraps 1 }
|
|
fsDhcp6RlyTrapInvalidMsgType OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object specifies the type of invalid message received
|
|
on a relay enabled interface."
|
|
::= { fsDhcp6RlyTraps 2 }
|
|
-- ******************************************************************
|
|
-- NOTIFICATION-TYPES
|
|
-- ******************************************************************
|
|
fsDhcp6RlyRlyInvalidPacketTrap NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
fsDhcp6RlyTrapInvalidMsgType,
|
|
fsDhcp6RlyTrapIfIndex
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This trap is generated when received Message is Invalid."
|
|
::= {fsDhcp6RlyNotify 1}
|
|
|
|
fsDhcp6RlyRlyMaxHopCountTrap NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
fsDhcp6RlyTrapIfIndex
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This trap is generated when relay agent is not able to
|
|
add the relay header because the received hop count value is
|
|
equal to the configured hop count value."
|
|
::= {fsDhcp6RlyNotify 2}
|
|
END
|