3377 lines
71 KiB
Plaintext
3377 lines
71 KiB
Plaintext
-- SMC-MIB
|
|
-- MIB generated on Monday, September 29, 2014 at 10:40:53
|
|
--
|
|
-- Super Micro top-level MIB
|
|
-- _SNMP
|
|
--
|
|
|
|
SMC-MIB DEFINITIONS ::= BEGIN
|
|
|
|
IMPORTS
|
|
OBJECT-GROUP
|
|
FROM SNMPv2-CONF
|
|
enterprises, IpAddress, Integer32, Unsigned32, OBJECT-TYPE,
|
|
MODULE-IDENTITY
|
|
FROM SNMPv2-SMI
|
|
PhysAddress
|
|
FROM SNMPv2-TC;
|
|
|
|
|
|
-- September 16, 2014 at 17:26 GMT
|
|
-- September 16, 2014 at 17:29 GMT
|
|
-- September 16, 2014 at 17:26 GMT
|
|
-- September 16, 2014 at 17:29 GMT
|
|
-- 1.3.6.1.4.1.10876
|
|
supermicro MODULE-IDENTITY
|
|
LAST-UPDATED "201409161726Z" -- September 16, 2014 at 17:26 GMT
|
|
ORGANIZATION
|
|
"Super Micro"
|
|
CONTACT-INFO
|
|
"Email: support@supermicro.com"
|
|
DESCRIPTION
|
|
"Top-level infrastructure of SMC MIB tree."
|
|
REVISION "201409161729Z" -- September 16, 2014 at 17:29 GMT
|
|
DESCRIPTION
|
|
"The module for SuperMicro Computer Ltd."
|
|
::= { enterprises 10876 }
|
|
|
|
|
|
|
|
|
|
--
|
|
-- Node definitions
|
|
--
|
|
|
|
-- Node definitions
|
|
--
|
|
-- 1.3.6.1.4.1.10876.1
|
|
cmm OBJECT IDENTIFIER ::= { supermicro 1 }
|
|
|
|
|
|
-- Network section
|
|
-- 1.3.6.1.4.1.10876.1.1
|
|
network OBJECT IDENTIFIER ::= { cmm 1 }
|
|
|
|
|
|
-- 1.3.6.1.4.1.10876.1.1.1
|
|
netGrpBasicSettings OBJECT-GROUP
|
|
OBJECTS { netMACAddr, netIPAutoConf, netHostName, netIPAddr, netNetmask,
|
|
netGateway, netDNS1, netDNS2 }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The group for network basic settings."
|
|
::= { network 1 }
|
|
|
|
|
|
-- 1.3.6.1.4.1.10876.1.1.2
|
|
netMACAddr OBJECT-TYPE
|
|
SYNTAX PhysAddress
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"CMM MAC address.
|
|
"
|
|
::= { network 2 }
|
|
|
|
|
|
-- 1.3.6.1.4.1.10876.1.1.3
|
|
netIPAutoConf OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
none(0),
|
|
dhcp(1),
|
|
bootp(2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"CMM IP auto configuration options.
|
|
Available options are None, DHCP, BOOTP.
|
|
"
|
|
::= { network 3 }
|
|
|
|
|
|
-- 1.3.6.1.4.1.10876.1.1.4
|
|
netHostName OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (0..63))
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"CMM host name in DHCP mode. User customizable.
|
|
"
|
|
::= { network 4 }
|
|
|
|
|
|
-- 1.3.6.1.4.1.10876.1.1.5
|
|
netIPAddr OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"CMM IPv4 address."
|
|
::= { network 5 }
|
|
|
|
|
|
-- 1.3.6.1.4.1.10876.1.1.6
|
|
netNetmask OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"CMM IPv4 subnet mask."
|
|
::= { network 6 }
|
|
|
|
|
|
-- 1.3.6.1.4.1.10876.1.1.7
|
|
netGateway OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"CMM IPv4 gateway IP address."
|
|
::= { network 7 }
|
|
|
|
|
|
-- 1.3.6.1.4.1.10876.1.1.8
|
|
netDNS1 OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"CMM primary DNS server IPv4 address."
|
|
::= { network 8 }
|
|
|
|
|
|
-- 1.3.6.1.4.1.10876.1.1.9
|
|
netDNS2 OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"CMM secondary DNS server IPv4 address."
|
|
::= { network 9 }
|
|
|
|
|
|
-- 1.3.6.1.4.1.10876.1.1.10
|
|
netGrpMiscSettings OBJECT-GROUP
|
|
OBJECTS { netPortHTTPS, netPortHTTP, netPortSSH,
|
|
netBandWidthLimit, netSSHAccess,
|
|
|
|
netSetupProtocol }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The group for network miscellaneous settings."
|
|
::= { network 10 }
|
|
|
|
|
|
-- 1.3.6.1.4.1.10876.1.1.11
|
|
netPortHTTPS OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Port for Remote Console & HTTPS."
|
|
::= { network 11 }
|
|
|
|
|
|
-- 1.3.6.1.4.1.10876.1.1.12
|
|
netPortHTTP OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Port for HTTP."
|
|
::= { network 12 }
|
|
|
|
|
|
-- 1.3.6.1.4.1.10876.1.1.13
|
|
netPortSSH OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Port for SSH."
|
|
::= { network 13 }
|
|
|
|
|
|
-- 1.3.6.1.4.1.10876.1.1.14
|
|
netBandWidthLimit OBJECT-TYPE
|
|
SYNTAX Integer32 (1..10000)
|
|
UNITS "kbit/s"
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Network Bandwidth limit setting. The MAX limitation is 10000 kbit/s"
|
|
::= { network 14 }
|
|
|
|
|
|
-- 1.3.6.1.4.1.10876.1.1.15
|
|
netSSHAccess OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
disabled(0),
|
|
enabled(1)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"SSH access enable/disable status."
|
|
::= { network 15 }
|
|
|
|
|
|
-- 1.3.6.1.4.1.10876.1.1.16
|
|
netSetupProtocol OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
disabled(0),
|
|
enabled(1)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Setup protocol enable/diable status."
|
|
::= { network 16 }
|
|
|
|
|
|
-- 1.3.6.1.4.1.10876.1.1.17
|
|
netGrpLANSettings OBJECT-GROUP
|
|
OBJECTS { netLANSpeed, netLANDuplexMode }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The group for LAN interface settings."
|
|
::= { network 17 }
|
|
|
|
|
|
-- 1.3.6.1.4.1.10876.1.1.18
|
|
netLANSpeed OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
autoDetect(0),
|
|
spd10M(1),
|
|
spd100M(2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"LAN interface speed.
|
|
Available options are AutoDetect, 10Mbps, 100Mbps."
|
|
::= { network 18 }
|
|
|
|
|
|
-- 1.3.6.1.4.1.10876.1.1.19
|
|
netLANDuplexMode OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
autoDetect(0),
|
|
halfDuplex(1),
|
|
fullDeplex(2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"LAN interface duplex mode.
|
|
Available options are AutoDetect, Half Duplex, Full Duplex."
|
|
::= { network 19 }
|
|
|
|
|
|
-- 1.3.6.1.4.1.10876.1.1.20
|
|
netGrpDDNSSettings OBJECT-GROUP
|
|
OBJECTS { netDDNSStatus, netDDNSServer, netDDNSSystemMode, netDDNSHostName
|
|
, netDDNSUserName,
|
|
|
|
netDDNSPassword, netDDNSCheckTime, netDDNSCheckInterval }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The group for dynamic DNS settings."
|
|
::= { network 20 }
|
|
|
|
|
|
-- 1.3.6.1.4.1.10876.1.1.21
|
|
netDDNSStatus OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
disabled(0),
|
|
enabled(1)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"DDNS enable/disable status."
|
|
::= { network 21 }
|
|
|
|
|
|
-- 1.3.6.1.4.1.10876.1.1.22
|
|
netDDNSServer OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"DDNS server."
|
|
::= { network 22 }
|
|
|
|
|
|
-- 1.3.6.1.4.1.10876.1.1.23
|
|
netDDNSSystemMode OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
dynamic(0),
|
|
custom(1)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"DDNS system mode.
|
|
Available options are Dynamic, Custom."
|
|
::= { network 23 }
|
|
|
|
|
|
-- 1.3.6.1.4.1.10876.1.1.24
|
|
netDDNSHostName OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"CMM host name in DDNS mode."
|
|
::= { network 24 }
|
|
|
|
|
|
-- 1.3.6.1.4.1.10876.1.1.25
|
|
netDDNSUserName OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"CMM user name in DDNS mode."
|
|
::= { network 25 }
|
|
|
|
|
|
-- 1.3.6.1.4.1.10876.1.1.26
|
|
netDDNSPassword OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"CMM password in DDNS mode."
|
|
::= { network 26 }
|
|
|
|
|
|
-- 1.3.6.1.4.1.10876.1.1.27
|
|
netDDNSCheckTime OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"DDNS check time."
|
|
::= { network 27 }
|
|
|
|
|
|
-- 1.3.6.1.4.1.10876.1.1.28
|
|
netDDNSCheckInterval OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
time24h(0),
|
|
time12h(1),
|
|
time6h(2),
|
|
time3h(3),
|
|
time2h(4),
|
|
time10min(5),
|
|
time1min(6)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"DDNS check interval.
|
|
Available options are 24h, 12h, 6h, 3h, 2h, 10min, 1min."
|
|
::= { network 28 }
|
|
|
|
|
|
-- Security section
|
|
-- 1.3.6.1.4.1.10876.1.2
|
|
security OBJECT IDENTIFIER ::= { cmm 2 }
|
|
|
|
|
|
-- 1.3.6.1.4.1.10876.1.2.1
|
|
secGrpEncryptionSettings OBJECT-GROUP
|
|
OBJECTS { secForceWebHTTPS, secKVMEncryption }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The group for encryption settings."
|
|
::= { security 1 }
|
|
|
|
|
|
-- 1.3.6.1.4.1.10876.1.2.2
|
|
secForceWebHTTPS OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
disabled(0),
|
|
enabled(1)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Force HTTPS for web access."
|
|
::= { security 2 }
|
|
|
|
|
|
-- 1.3.6.1.4.1.10876.1.2.3
|
|
secKVMEncryption OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
off(0),
|
|
try(1),
|
|
force(2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"KVM encryption setting.
|
|
Available options are Off, Try, Force."
|
|
::= { security 3 }
|
|
|
|
|
|
-- 1.3.6.1.4.1.10876.1.2.4
|
|
secGrpIPAccessControl OBJECT-GROUP
|
|
OBJECTS { secIPFWStatus, secIPFWDefaultPolicy }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The group for IP access control settings."
|
|
::= { security 4 }
|
|
|
|
|
|
-- 1.3.6.1.4.1.10876.1.2.5
|
|
secIPFWStatus OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
disabled(0),
|
|
enabled(1)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"IP Access Control enable/disable status."
|
|
::= { security 5 }
|
|
|
|
|
|
-- 1.3.6.1.4.1.10876.1.2.6
|
|
secIPFWDefaultPolicy OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
accept(0),
|
|
drop(1)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Default policy for IP access control."
|
|
::= { security 6 }
|
|
|
|
|
|
-- 1.3.6.1.4.1.10876.1.2.7
|
|
secGrpLoginFailBlocking OBJECT-GROUP
|
|
OBJECTS { secLoginRetryCount, secLoginBlockTime }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The group for login failure blocking settings."
|
|
::= { security 7 }
|
|
|
|
|
|
-- 1.3.6.1.4.1.10876.1.2.8
|
|
secLoginRetryCount OBJECT-TYPE
|
|
SYNTAX Integer32 (-1 | 0..1024)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Max number of failed login attempts [0..1024].
|
|
-1 for Infinite."
|
|
::= { security 8 }
|
|
|
|
|
|
-- 1.3.6.1.4.1.10876.1.2.9
|
|
secLoginBlockTime OBJECT-TYPE
|
|
SYNTAX Integer32 (-1 | 0..10080)
|
|
UNITS "minute"
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Block time for the login failure retry limit reached [0..10080]min.
|
|
-1 for infinite."
|
|
::= { security 9 }
|
|
|
|
|
|
-- 1.3.6.1.4.1.10876.1.2.10
|
|
secIPMISettings OBJECT-GROUP
|
|
OBJECTS { secSMCRAKP }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The group for IPMI security control settings"
|
|
::= { security 10 }
|
|
|
|
|
|
-- 1.3.6.1.4.1.10876.1.2.11
|
|
secSMCRAKP OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
disabled(0),
|
|
enabled(1)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"SMC RAKP feature enable/disable. It's disabled by default.
|
|
IPMI LAN channel will be disabled while this inidication is enabled.
|
|
"
|
|
::= { security 11 }
|
|
|
|
|
|
-- User Management section
|
|
-- 1.3.6.1.4.1.10876.1.3
|
|
users OBJECT IDENTIFIER ::= { cmm 3 }
|
|
|
|
|
|
-- 1.3.6.1.4.1.10876.1.3.1
|
|
userMgmtTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF UserMgmtEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This is the table for CMM user account management."
|
|
::= { users 1 }
|
|
|
|
|
|
-- 1.3.6.1.4.1.10876.1.3.1.1
|
|
userMgmtEntry OBJECT-TYPE
|
|
SYNTAX UserMgmtEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The table entry for a CMM user."
|
|
INDEX { userIndex }
|
|
::= { userMgmtTable 1 }
|
|
|
|
|
|
UserMgmtEntry ::=
|
|
SEQUENCE {
|
|
userIndex
|
|
Integer32,
|
|
userPresence
|
|
INTEGER,
|
|
userName
|
|
OCTET STRING,
|
|
userFullName
|
|
OCTET STRING,
|
|
userPassword
|
|
OCTET STRING,
|
|
userEmail
|
|
OCTET STRING,
|
|
userMobile
|
|
OCTET STRING,
|
|
userPriv
|
|
INTEGER
|
|
}
|
|
|
|
-- 1.3.6.1.4.1.10876.1.3.1.1.1
|
|
userIndex OBJECT-TYPE
|
|
SYNTAX Integer32 (1..65535)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The index for user management table."
|
|
::= { userMgmtEntry 1 }
|
|
|
|
|
|
-- 1.3.6.1.4.1.10876.1.3.1.1.2
|
|
userPresence OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
notPresent(0),
|
|
present(1)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The indication for user presence."
|
|
::= { userMgmtEntry 2 }
|
|
|
|
|
|
-- 1.3.6.1.4.1.10876.1.3.1.1.3
|
|
userName OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (0..15))
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The indication for user name."
|
|
::= { userMgmtEntry 3 }
|
|
|
|
|
|
-- 1.3.6.1.4.1.10876.1.3.1.1.4
|
|
userFullName OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (0..15))
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The indication for user full name."
|
|
::= { userMgmtEntry 4 }
|
|
|
|
|
|
-- 1.3.6.1.4.1.10876.1.3.1.1.5
|
|
userPassword OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (0..19))
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The indication for user password."
|
|
::= { userMgmtEntry 5 }
|
|
|
|
|
|
-- 1.3.6.1.4.1.10876.1.3.1.1.6
|
|
userEmail OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (0..63))
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The indication for user email address."
|
|
::= { userMgmtEntry 6 }
|
|
|
|
|
|
-- 1.3.6.1.4.1.10876.1.3.1.1.7
|
|
userMobile OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (0..63))
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The indication for user mobile number."
|
|
::= { userMgmtEntry 7 }
|
|
|
|
|
|
-- 1.3.6.1.4.1.10876.1.3.1.1.8
|
|
userPriv OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
noaccess(0),
|
|
user(1),
|
|
operator(2),
|
|
administrator(3),
|
|
oem(4)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The indication for user IPMI privilege."
|
|
::= { userMgmtEntry 8 }
|
|
|
|
|
|
-- Blade Management section
|
|
-- 1.3.6.1.4.1.10876.1.4
|
|
blades OBJECT IDENTIFIER ::= { cmm 4 }
|
|
|
|
|
|
-- 1.3.6.1.4.1.10876.1.4.1
|
|
bladeTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF BladeEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The table for blade summary from the CMM management perspective."
|
|
::= { blades 1 }
|
|
|
|
|
|
-- 1.3.6.1.4.1.10876.1.4.1.1
|
|
bladeEntry OBJECT-TYPE
|
|
SYNTAX BladeEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The table entry for blade summary information."
|
|
INDEX { bladeIndex }
|
|
::= { bladeTable 1 }
|
|
|
|
|
|
BladeEntry ::=
|
|
SEQUENCE {
|
|
bladeIndex
|
|
Integer32,
|
|
bladeSlotID
|
|
Integer32,
|
|
bladePresence
|
|
INTEGER,
|
|
bladeName
|
|
OCTET STRING,
|
|
bladeModel
|
|
OCTET STRING,
|
|
bladePowerStatus
|
|
INTEGER,
|
|
bladePowerWatt
|
|
Integer32,
|
|
bladePowerControl
|
|
INTEGER,
|
|
bladeACLostPolicy
|
|
INTEGER,
|
|
bladeKVMStatus
|
|
INTEGER,
|
|
bladeUID
|
|
INTEGER,
|
|
bladeError
|
|
INTEGER,
|
|
bladeMgmtIPAddr
|
|
IpAddress,
|
|
bladeSN
|
|
OCTET STRING,
|
|
bladeBMCVersion
|
|
OCTET STRING,
|
|
bladeBIOSVersion
|
|
OCTET STRING
|
|
}
|
|
|
|
-- 1.3.6.1.4.1.10876.1.4.1.1.1
|
|
bladeIndex OBJECT-TYPE
|
|
SYNTAX Integer32 (1..65535)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The index for blade table."
|
|
::= { bladeEntry 1 }
|
|
|
|
|
|
-- 1.3.6.1.4.1.10876.1.4.1.1.2
|
|
bladeSlotID OBJECT-TYPE
|
|
SYNTAX Integer32 (1..128)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The indication for blade slot ID."
|
|
::= { bladeEntry 2 }
|
|
|
|
|
|
-- 1.3.6.1.4.1.10876.1.4.1.1.3
|
|
bladePresence OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
notPresent(0),
|
|
present(1)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The indication for blade presence."
|
|
::= { bladeEntry 3 }
|
|
|
|
|
|
-- 1.3.6.1.4.1.10876.1.4.1.1.4
|
|
bladeName OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The indication for blade name."
|
|
::= { bladeEntry 4 }
|
|
|
|
|
|
-- 1.3.6.1.4.1.10876.1.4.1.1.5
|
|
bladeModel OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The indication for blade model."
|
|
::= { bladeEntry 5 }
|
|
|
|
|
|
-- 1.3.6.1.4.1.10876.1.4.1.1.6
|
|
bladePowerStatus OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
powerOff(0),
|
|
powerOn(1),
|
|
powerReset(2),
|
|
powerGracefulShutdown(3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The indication for blade power status and control."
|
|
::= { bladeEntry 6 }
|
|
|
|
|
|
-- 1.3.6.1.4.1.10876.1.4.1.1.7
|
|
bladePowerWatt OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "W"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The indication for blade current power consumption."
|
|
::= { bladeEntry 7 }
|
|
|
|
|
|
-- 1.3.6.1.4.1.10876.1.4.1.1.8
|
|
bladePowerControl OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
powerCtrl0per(0),
|
|
powerCtrl50per(1),
|
|
powerCtrlFull(2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The indication for blade power control."
|
|
::= { bladeEntry 8 }
|
|
|
|
|
|
-- 1.3.6.1.4.1.10876.1.4.1.1.9
|
|
bladeACLostPolicy OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
powerOff(0),
|
|
powerOn(1),
|
|
lastState(2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The indication for blade AC power lost policy."
|
|
::= { bladeEntry 9 }
|
|
|
|
|
|
-- 1.3.6.1.4.1.10876.1.4.1.1.10
|
|
bladeKVMStatus OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
deselected(0),
|
|
selected(1)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The indication for blade KVM status."
|
|
::= { bladeEntry 10 }
|
|
|
|
|
|
-- 1.3.6.1.4.1.10876.1.4.1.1.11
|
|
bladeUID OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
off(0),
|
|
on(1)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The indication for blade UID status and control."
|
|
::= { bladeEntry 11 }
|
|
|
|
|
|
-- 1.3.6.1.4.1.10876.1.4.1.1.12
|
|
bladeError OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
normal(0),
|
|
error(1)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The indication for blade error status."
|
|
::= { bladeEntry 12 }
|
|
|
|
|
|
-- 1.3.6.1.4.1.10876.1.4.1.1.13
|
|
bladeMgmtIPAddr OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The indication for blade BMC IPv4 address."
|
|
::= { bladeEntry 13 }
|
|
|
|
|
|
-- 1.3.6.1.4.1.10876.1.4.1.1.14
|
|
bladeSN OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The indication for blade serial number."
|
|
::= { bladeEntry 14 }
|
|
|
|
|
|
-- 1.3.6.1.4.1.10876.1.4.1.1.15
|
|
bladeBMCVersion OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The indication for blade BMC version."
|
|
::= { bladeEntry 15 }
|
|
|
|
|
|
-- 1.3.6.1.4.1.10876.1.4.1.1.16
|
|
bladeBIOSVersion OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The indication for blade BIOS version."
|
|
::= { bladeEntry 16 }
|
|
|
|
|
|
-- Switch Management section
|
|
-- 1.3.6.1.4.1.10876.1.5
|
|
switches OBJECT IDENTIFIER ::= { cmm 5 }
|
|
|
|
|
|
-- 1.3.6.1.4.1.10876.1.5.1
|
|
switchGBTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF SwitchGBEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The table for gigabit switch summary from the CMM management perspective."
|
|
::= { switches 1 }
|
|
|
|
|
|
-- 1.3.6.1.4.1.10876.1.5.1.1
|
|
switchGBEntry OBJECT-TYPE
|
|
SYNTAX SwitchGBEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The table entry for gigabit switch summary information management."
|
|
INDEX { switchGBIndex }
|
|
::= { switchGBTable 1 }
|
|
|
|
|
|
SwitchGBEntry ::=
|
|
SEQUENCE {
|
|
switchGBIndex
|
|
Integer32,
|
|
switchGBSlotID
|
|
Integer32,
|
|
switchGBPresence
|
|
INTEGER,
|
|
switchGBName
|
|
OCTET STRING,
|
|
switchGBModel
|
|
OCTET STRING,
|
|
switchGBPowerStatus
|
|
INTEGER,
|
|
switchGBTemperature
|
|
Integer32,
|
|
switchGBError
|
|
INTEGER,
|
|
switchGBInitialized
|
|
INTEGER,
|
|
switchGB2V5
|
|
OCTET STRING,
|
|
switchGB1V25
|
|
OCTET STRING
|
|
}
|
|
|
|
-- 1.3.6.1.4.1.10876.1.5.1.1.1
|
|
switchGBIndex OBJECT-TYPE
|
|
SYNTAX Integer32 (1..65535)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The index for gigabit switch table."
|
|
::= { switchGBEntry 1 }
|
|
|
|
|
|
-- 1.3.6.1.4.1.10876.1.5.1.1.2
|
|
switchGBSlotID OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The indication of switch slot."
|
|
::= { switchGBEntry 2 }
|
|
|
|
|
|
-- 1.3.6.1.4.1.10876.1.5.1.1.3
|
|
switchGBPresence OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
notPresent(0),
|
|
present(1)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The indication for switch presence."
|
|
::= { switchGBEntry 3 }
|
|
|
|
|
|
-- 1.3.6.1.4.1.10876.1.5.1.1.4
|
|
switchGBName OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The indication for switch name."
|
|
::= { switchGBEntry 4 }
|
|
|
|
|
|
-- 1.3.6.1.4.1.10876.1.5.1.1.5
|
|
switchGBModel OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (0..16))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The indication for switch model."
|
|
::= { switchGBEntry 5 }
|
|
|
|
|
|
-- 1.3.6.1.4.1.10876.1.5.1.1.6
|
|
switchGBPowerStatus OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
powerOff(0),
|
|
powerOn(1),
|
|
restart(2),
|
|
reset(3),
|
|
resetFactoryDefaults(4)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The indication for switch power status."
|
|
::= { switchGBEntry 6 }
|
|
|
|
|
|
-- 1.3.6.1.4.1.10876.1.5.1.1.7
|
|
switchGBTemperature OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "C"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The indication for switch temperature."
|
|
::= { switchGBEntry 7 }
|
|
|
|
|
|
-- 1.3.6.1.4.1.10876.1.5.1.1.8
|
|
switchGBError OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
normal(0),
|
|
error(1)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The indication for switch error status."
|
|
::= { switchGBEntry 8 }
|
|
|
|
|
|
-- 1.3.6.1.4.1.10876.1.5.1.1.9
|
|
switchGBInitialized OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
notready(0),
|
|
ok(1)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The indication for switch initialization status."
|
|
::= { switchGBEntry 9 }
|
|
|
|
|
|
-- 1.3.6.1.4.1.10876.1.5.1.1.10
|
|
switchGB2V5 OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
UNITS "V"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The indication for switch 2.5V voltage."
|
|
::= { switchGBEntry 10 }
|
|
|
|
|
|
-- 1.3.6.1.4.1.10876.1.5.1.1.11
|
|
switchGB1V25 OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
UNITS "V"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The indication for switch 1.25V voltage."
|
|
::= { switchGBEntry 11 }
|
|
|
|
|
|
-- 1.3.6.1.4.1.10876.1.5.2
|
|
switch10GBTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF Switch10GBEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The table for 10 gigabit switch summary from the CMM management
|
|
perspective."
|
|
::= { switches 2 }
|
|
|
|
|
|
-- 1.3.6.1.4.1.10876.1.5.2.1
|
|
switch10GBEntry OBJECT-TYPE
|
|
SYNTAX Switch10GBEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The table entry for 10 gigabit switch summary information management."
|
|
INDEX { switch10GBIndex }
|
|
::= { switch10GBTable 1 }
|
|
|
|
|
|
Switch10GBEntry ::=
|
|
SEQUENCE {
|
|
switch10GBIndex
|
|
Integer32,
|
|
switch10GBSlotID
|
|
Integer32,
|
|
switch10GBPresence
|
|
INTEGER,
|
|
switch10GBName
|
|
OCTET STRING,
|
|
switch10GBModel
|
|
OCTET STRING,
|
|
switch10GBPowerStatus
|
|
INTEGER,
|
|
switch10GBTemperature
|
|
Integer32,
|
|
switch10GBError
|
|
INTEGER,
|
|
switch10GBInitialized
|
|
INTEGER,
|
|
switch10GB3V3
|
|
OCTET STRING,
|
|
switch10GB1V25
|
|
OCTET STRING
|
|
}
|
|
|
|
-- 1.3.6.1.4.1.10876.1.5.2.1.1
|
|
switch10GBIndex OBJECT-TYPE
|
|
SYNTAX Integer32 (1..65535)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The index for 10 gigabit switch table."
|
|
::= { switch10GBEntry 1 }
|
|
|
|
|
|
-- 1.3.6.1.4.1.10876.1.5.2.1.2
|
|
switch10GBSlotID OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The indication of switch slot."
|
|
::= { switch10GBEntry 2 }
|
|
|
|
|
|
-- 1.3.6.1.4.1.10876.1.5.2.1.3
|
|
switch10GBPresence OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
notPresent(0),
|
|
present(1)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The indication for switch presence."
|
|
::= { switch10GBEntry 3 }
|
|
|
|
|
|
-- 1.3.6.1.4.1.10876.1.5.2.1.4
|
|
switch10GBName OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The indication for switch name."
|
|
::= { switch10GBEntry 4 }
|
|
|
|
|
|
-- 1.3.6.1.4.1.10876.1.5.2.1.5
|
|
switch10GBModel OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (0..16))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The indication for switch model."
|
|
::= { switch10GBEntry 5 }
|
|
|
|
|
|
-- 1.3.6.1.4.1.10876.1.5.2.1.6
|
|
switch10GBPowerStatus OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
powerOff(0),
|
|
powerOn(1),
|
|
restart(2),
|
|
reset(3),
|
|
resetFactoryDefaults(4)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The indication for switch power status."
|
|
::= { switch10GBEntry 6 }
|
|
|
|
|
|
-- 1.3.6.1.4.1.10876.1.5.2.1.7
|
|
switch10GBTemperature OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "C"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The indication for switch temperature."
|
|
::= { switch10GBEntry 7 }
|
|
|
|
|
|
-- 1.3.6.1.4.1.10876.1.5.2.1.8
|
|
switch10GBError OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
normal(0),
|
|
error(1)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The indication for switch error status."
|
|
::= { switch10GBEntry 8 }
|
|
|
|
|
|
-- 1.3.6.1.4.1.10876.1.5.2.1.9
|
|
switch10GBInitialized OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
notready(0),
|
|
ok(1)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The indication for switch initialization status."
|
|
::= { switch10GBEntry 9 }
|
|
|
|
|
|
-- 1.3.6.1.4.1.10876.1.5.2.1.10
|
|
switch10GB3V3 OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
UNITS "V"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The indication for switch 3.3V voltage."
|
|
::= { switch10GBEntry 10 }
|
|
|
|
|
|
-- 1.3.6.1.4.1.10876.1.5.2.1.11
|
|
switch10GB1V25 OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
UNITS "V"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The indication for switch 1.25V voltage."
|
|
::= { switch10GBEntry 11 }
|
|
|
|
|
|
-- 1.3.6.1.4.1.10876.1.5.3
|
|
passthru10GBTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF Passthru10GBEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The table for 10 gigabit passthrough summary from the CMM management
|
|
perspective."
|
|
::= { switches 3 }
|
|
|
|
|
|
-- 1.3.6.1.4.1.10876.1.5.3.1
|
|
passthru10GBEntry OBJECT-TYPE
|
|
SYNTAX Passthru10GBEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The table entry for 10 gigabit passthrough summary information management
|
|
."
|
|
INDEX { passthru10GBIndex }
|
|
::= { passthru10GBTable 1 }
|
|
|
|
|
|
Passthru10GBEntry ::=
|
|
SEQUENCE {
|
|
passthru10GBIndex
|
|
Integer32,
|
|
passthru10GBSlotID
|
|
Integer32,
|
|
passthru10GBPresence
|
|
INTEGER,
|
|
passthru10GBName
|
|
OCTET STRING,
|
|
passthru10GBModel
|
|
OCTET STRING,
|
|
passthru10GBPowerStatus
|
|
INTEGER,
|
|
passthru10GBTemperature
|
|
Integer32,
|
|
passthru10GBError
|
|
INTEGER,
|
|
passthru10GBInitialized
|
|
INTEGER,
|
|
passthru10GB3V3
|
|
OCTET STRING,
|
|
passthru10GB1V25
|
|
OCTET STRING
|
|
}
|
|
|
|
-- 1.3.6.1.4.1.10876.1.5.3.1.1
|
|
passthru10GBIndex OBJECT-TYPE
|
|
SYNTAX Integer32 (1..65535)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The index for 10 gigabit passthrough table."
|
|
::= { passthru10GBEntry 1 }
|
|
|
|
|
|
-- 1.3.6.1.4.1.10876.1.5.3.1.2
|
|
passthru10GBSlotID OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The indication of passthrough slot."
|
|
::= { passthru10GBEntry 2 }
|
|
|
|
|
|
-- 1.3.6.1.4.1.10876.1.5.3.1.3
|
|
passthru10GBPresence OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
notPresent(0),
|
|
present(1)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The indication for passthrough presence."
|
|
::= { passthru10GBEntry 3 }
|
|
|
|
|
|
-- 1.3.6.1.4.1.10876.1.5.3.1.4
|
|
passthru10GBName OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The indication for passthrough name."
|
|
::= { passthru10GBEntry 4 }
|
|
|
|
|
|
-- 1.3.6.1.4.1.10876.1.5.3.1.5
|
|
passthru10GBModel OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (0..16))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The indication for passthrough model."
|
|
::= { passthru10GBEntry 5 }
|
|
|
|
|
|
-- 1.3.6.1.4.1.10876.1.5.3.1.6
|
|
passthru10GBPowerStatus OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
powerOff(0),
|
|
powerOn(1),
|
|
restart(2),
|
|
reset(3),
|
|
resetFactoryDefaults(4)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The indication for passthrough power status."
|
|
::= { passthru10GBEntry 6 }
|
|
|
|
|
|
-- 1.3.6.1.4.1.10876.1.5.3.1.7
|
|
passthru10GBTemperature OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "C"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The indication for passthrough temperature."
|
|
::= { passthru10GBEntry 7 }
|
|
|
|
|
|
-- 1.3.6.1.4.1.10876.1.5.3.1.8
|
|
passthru10GBError OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
normal(0),
|
|
error(1)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The indication for passthrough error status."
|
|
::= { passthru10GBEntry 8 }
|
|
|
|
|
|
-- 1.3.6.1.4.1.10876.1.5.3.1.9
|
|
passthru10GBInitialized OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
notready(0),
|
|
ok(1)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The indication for passthrough initialization status."
|
|
::= { passthru10GBEntry 9 }
|
|
|
|
|
|
-- 1.3.6.1.4.1.10876.1.5.3.1.10
|
|
passthru10GB3V3 OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
UNITS "V"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The indication for passthrough 3.3V voltage."
|
|
::= { passthru10GBEntry 10 }
|
|
|
|
|
|
-- 1.3.6.1.4.1.10876.1.5.3.1.11
|
|
passthru10GB1V25 OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
UNITS "V"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The indication for passthrough 1.25V voltage."
|
|
::= { passthru10GBEntry 11 }
|
|
|
|
|
|
-- 1.3.6.1.4.1.10876.1.5.4
|
|
switchIBTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF SwitchIBEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The table for IB switch summary from the CMM management
|
|
perspective."
|
|
::= { switches 4 }
|
|
|
|
|
|
-- 1.3.6.1.4.1.10876.1.5.4.1
|
|
switchIBEntry OBJECT-TYPE
|
|
SYNTAX SwitchIBEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The table entry for IB switch summary information management."
|
|
INDEX { switchIBIndex }
|
|
::= { switchIBTable 1 }
|
|
|
|
|
|
SwitchIBEntry ::=
|
|
SEQUENCE {
|
|
switchIBIndex
|
|
Integer32,
|
|
switchIBSlotID
|
|
Integer32,
|
|
switchIBPresence
|
|
INTEGER,
|
|
switchIBName
|
|
OCTET STRING,
|
|
switchIBModel
|
|
OCTET STRING,
|
|
switchIBPowerStatus
|
|
INTEGER,
|
|
switchIBTemperature
|
|
Integer32,
|
|
switchIBInitialized
|
|
INTEGER,
|
|
switchIB3V3Aux
|
|
OCTET STRING,
|
|
switchIB3V3
|
|
OCTET STRING,
|
|
switchIB1V8
|
|
OCTET STRING,
|
|
switchIB1V2
|
|
OCTET STRING,
|
|
switchIBVVdd
|
|
OCTET STRING
|
|
}
|
|
|
|
-- 1.3.6.1.4.1.10876.1.5.4.1.1
|
|
switchIBIndex OBJECT-TYPE
|
|
SYNTAX Integer32 (1..65535)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The index for IB switch table."
|
|
::= { switchIBEntry 1 }
|
|
|
|
|
|
-- 1.3.6.1.4.1.10876.1.5.4.1.2
|
|
switchIBSlotID OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The indication of switch slot."
|
|
::= { switchIBEntry 2 }
|
|
|
|
|
|
-- 1.3.6.1.4.1.10876.1.5.4.1.3
|
|
switchIBPresence OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
notPresent(0),
|
|
present(1)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The indication for switch presence."
|
|
::= { switchIBEntry 3 }
|
|
|
|
|
|
-- 1.3.6.1.4.1.10876.1.5.4.1.4
|
|
switchIBName OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The indication for switch name."
|
|
::= { switchIBEntry 4 }
|
|
|
|
|
|
-- 1.3.6.1.4.1.10876.1.5.4.1.5
|
|
switchIBModel OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (0..16))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The indication for switch model."
|
|
::= { switchIBEntry 5 }
|
|
|
|
|
|
-- 1.3.6.1.4.1.10876.1.5.4.1.6
|
|
switchIBPowerStatus OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
powerOff(0),
|
|
powerOn(1),
|
|
reset(2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The indication for switch power status."
|
|
::= { switchIBEntry 6 }
|
|
|
|
|
|
-- 1.3.6.1.4.1.10876.1.5.4.1.7
|
|
switchIBTemperature OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "C"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The indication for switch temperature."
|
|
::= { switchIBEntry 7 }
|
|
|
|
|
|
-- 1.3.6.1.4.1.10876.1.5.4.1.8
|
|
switchIBInitialized OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
notready(0),
|
|
ok(1)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The indication for switch initialization status."
|
|
::= { switchIBEntry 8 }
|
|
|
|
|
|
-- 1.3.6.1.4.1.10876.1.5.4.1.9
|
|
switchIB3V3Aux OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
UNITS "V"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The indication for switch 3.3V AUX voltage."
|
|
::= { switchIBEntry 9 }
|
|
|
|
|
|
-- 1.3.6.1.4.1.10876.1.5.4.1.10
|
|
switchIB3V3 OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
UNITS "V"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The indication for switch 3.3V voltage."
|
|
::= { switchIBEntry 10 }
|
|
|
|
|
|
-- 1.3.6.1.4.1.10876.1.5.4.1.11
|
|
switchIB1V8 OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
UNITS "V"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The indication for switch 1.8V voltage."
|
|
::= { switchIBEntry 11 }
|
|
|
|
|
|
-- 1.3.6.1.4.1.10876.1.5.4.1.12
|
|
switchIB1V2 OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
UNITS "V"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The indication for switch 1.2V voltage."
|
|
::= { switchIBEntry 12 }
|
|
|
|
|
|
-- 1.3.6.1.4.1.10876.1.5.4.1.13
|
|
switchIBVVdd OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
UNITS "V"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The indication for switch VVDD voltage."
|
|
::= { switchIBEntry 13 }
|
|
|
|
|
|
-- 1.3.6.1.4.1.10876.1.5.5
|
|
switchIBQDRTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF SwitchIBQDREntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The table for IB QDR switch summary from the CMM management
|
|
perspective."
|
|
::= { switches 5 }
|
|
|
|
|
|
-- 1.3.6.1.4.1.10876.1.5.5.1
|
|
switchIBQDREntry OBJECT-TYPE
|
|
SYNTAX SwitchIBQDREntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The table entry for IB QDR switch summary information management."
|
|
INDEX { switchIBQDRIndex }
|
|
::= { switchIBQDRTable 1 }
|
|
|
|
|
|
SwitchIBQDREntry ::=
|
|
SEQUENCE {
|
|
switchIBQDRIndex
|
|
Integer32,
|
|
switchIBQDRSlotID
|
|
Integer32,
|
|
switchIBQDRPresence
|
|
INTEGER,
|
|
switchIBQDRName
|
|
OCTET STRING,
|
|
switchIBQDRModel
|
|
OCTET STRING,
|
|
switchIBQDRPowerStatus
|
|
INTEGER,
|
|
switchIBQDRTemperature
|
|
Integer32,
|
|
switchIBQDRInitialized
|
|
INTEGER,
|
|
switchIBQDRError
|
|
INTEGER,
|
|
switchIBQDR3V3
|
|
OCTET STRING,
|
|
switchIBQDR1V25
|
|
OCTET STRING
|
|
}
|
|
|
|
-- 1.3.6.1.4.1.10876.1.5.5.1.1
|
|
switchIBQDRIndex OBJECT-TYPE
|
|
SYNTAX Integer32 (1..65535)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The index for IB QDR switch table."
|
|
::= { switchIBQDREntry 1 }
|
|
|
|
|
|
-- 1.3.6.1.4.1.10876.1.5.5.1.2
|
|
switchIBQDRSlotID OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The indication of switch slot."
|
|
::= { switchIBQDREntry 2 }
|
|
|
|
|
|
-- 1.3.6.1.4.1.10876.1.5.5.1.3
|
|
switchIBQDRPresence OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
notPresent(0),
|
|
present(1)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The indication for switch presence."
|
|
::= { switchIBQDREntry 3 }
|
|
|
|
|
|
-- 1.3.6.1.4.1.10876.1.5.5.1.4
|
|
switchIBQDRName OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The indication for switch name."
|
|
::= { switchIBQDREntry 4 }
|
|
|
|
|
|
-- 1.3.6.1.4.1.10876.1.5.5.1.5
|
|
switchIBQDRModel OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (0..16))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The indication for switch model."
|
|
::= { switchIBQDREntry 5 }
|
|
|
|
|
|
-- 1.3.6.1.4.1.10876.1.5.5.1.6
|
|
switchIBQDRPowerStatus OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
powerOff(0),
|
|
powerOn(1),
|
|
reset(2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The indication for switch power status."
|
|
::= { switchIBQDREntry 6 }
|
|
|
|
|
|
-- 1.3.6.1.4.1.10876.1.5.5.1.7
|
|
switchIBQDRTemperature OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "C"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The indication for switch temperature."
|
|
::= { switchIBQDREntry 7 }
|
|
|
|
|
|
-- 1.3.6.1.4.1.10876.1.5.5.1.8
|
|
switchIBQDRInitialized OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
notready(0),
|
|
ok(1)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The indication for switch initialization status."
|
|
::= { switchIBQDREntry 8 }
|
|
|
|
|
|
-- 1.3.6.1.4.1.10876.1.5.5.1.9
|
|
switchIBQDRError OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
normal(0),
|
|
error(1)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The indication for switch error status."
|
|
::= { switchIBQDREntry 9 }
|
|
|
|
|
|
-- 1.3.6.1.4.1.10876.1.5.5.1.10
|
|
switchIBQDR3V3 OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
UNITS "V"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The indication for switch 3.3V voltage."
|
|
::= { switchIBQDREntry 10 }
|
|
|
|
|
|
-- 1.3.6.1.4.1.10876.1.5.5.1.11
|
|
switchIBQDR1V25 OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
UNITS "V"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The indication for switch 1.25V voltage."
|
|
::= { switchIBQDREntry 11 }
|
|
|
|
|
|
-- 1.3.6.1.4.1.10876.1.5.6
|
|
switchIBFDRTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF SwitchIBFDREntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The table for IB FDR switch summary from the CMM management
|
|
perspective."
|
|
::= { switches 6 }
|
|
|
|
|
|
-- 1.3.6.1.4.1.10876.1.5.6.1
|
|
switchIBFDREntry OBJECT-TYPE
|
|
SYNTAX SwitchIBFDREntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The table entry for IB FDR switch summary information management."
|
|
INDEX { switchIBFDRIndex }
|
|
::= { switchIBFDRTable 1 }
|
|
|
|
|
|
SwitchIBFDREntry ::=
|
|
SEQUENCE {
|
|
switchIBFDRIndex
|
|
Integer32,
|
|
switchIBFDRSlotID
|
|
Integer32,
|
|
switchIBFDRPresence
|
|
INTEGER,
|
|
switchIBFDRName
|
|
OCTET STRING,
|
|
switchIBFDRModel
|
|
OCTET STRING,
|
|
switchIBFDRPowerStatus
|
|
INTEGER,
|
|
switchIBFDRTemp1
|
|
Integer32,
|
|
switchIBFDRTemp2
|
|
Integer32,
|
|
switchIBFDRInitialized
|
|
INTEGER,
|
|
switchIBFDRError
|
|
INTEGER,
|
|
switchIBFDR3V3
|
|
OCTET STRING,
|
|
switchIBFDR1V2
|
|
OCTET STRING,
|
|
switchIBFDR0V9
|
|
OCTET STRING
|
|
}
|
|
|
|
-- 1.3.6.1.4.1.10876.1.5.6.1.1
|
|
switchIBFDRIndex OBJECT-TYPE
|
|
SYNTAX Integer32 (1..65535)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The index for IB FDR switch table."
|
|
::= { switchIBFDREntry 1 }
|
|
|
|
|
|
-- 1.3.6.1.4.1.10876.1.5.6.1.2
|
|
switchIBFDRSlotID OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The indication of switch slot."
|
|
::= { switchIBFDREntry 2 }
|
|
|
|
|
|
-- 1.3.6.1.4.1.10876.1.5.6.1.3
|
|
switchIBFDRPresence OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
notPresent(0),
|
|
present(1)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The indication for switch presence."
|
|
::= { switchIBFDREntry 3 }
|
|
|
|
|
|
-- 1.3.6.1.4.1.10876.1.5.6.1.4
|
|
switchIBFDRName OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The indication for switch name."
|
|
::= { switchIBFDREntry 4 }
|
|
|
|
|
|
-- 1.3.6.1.4.1.10876.1.5.6.1.5
|
|
switchIBFDRModel OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (0..16))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The indication for switch model."
|
|
::= { switchIBFDREntry 5 }
|
|
|
|
|
|
-- 1.3.6.1.4.1.10876.1.5.6.1.6
|
|
switchIBFDRPowerStatus OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
powerOff(0),
|
|
powerOn(1),
|
|
reset(2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The indication for switch power status."
|
|
::= { switchIBFDREntry 6 }
|
|
|
|
|
|
-- 1.3.6.1.4.1.10876.1.5.6.1.7
|
|
switchIBFDRTemp1 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "C"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The indication for switch temperature 1."
|
|
::= { switchIBFDREntry 7 }
|
|
|
|
|
|
-- 1.3.6.1.4.1.10876.1.5.6.1.8
|
|
switchIBFDRTemp2 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "C"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The indication for switch temperature 2."
|
|
::= { switchIBFDREntry 8 }
|
|
|
|
|
|
-- 1.3.6.1.4.1.10876.1.5.6.1.9
|
|
switchIBFDRInitialized OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
notready(0),
|
|
ok(1)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The indication for switch initialization status."
|
|
::= { switchIBFDREntry 9 }
|
|
|
|
|
|
-- 1.3.6.1.4.1.10876.1.5.6.1.10
|
|
switchIBFDRError OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
normal(0),
|
|
error(1)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The indication for switch error status."
|
|
::= { switchIBFDREntry 10 }
|
|
|
|
|
|
-- 1.3.6.1.4.1.10876.1.5.6.1.11
|
|
switchIBFDR3V3 OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
UNITS "V"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The indication for switch 3.3V voltage."
|
|
::= { switchIBFDREntry 11 }
|
|
|
|
|
|
-- 1.3.6.1.4.1.10876.1.5.6.1.12
|
|
switchIBFDR1V2 OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
UNITS "V"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The indication for switch 1.2V voltage."
|
|
::= { switchIBFDREntry 12 }
|
|
|
|
|
|
-- 1.3.6.1.4.1.10876.1.5.6.1.13
|
|
switchIBFDR0V9 OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
UNITS "V"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The indication for switch 0.9V voltage."
|
|
::= { switchIBFDREntry 13 }
|
|
|
|
|
|
-- Power Management section
|
|
-- 1.3.6.1.4.1.10876.1.6
|
|
powerSupplies OBJECT IDENTIFIER ::= { cmm 6 }
|
|
|
|
|
|
-- 1.3.6.1.4.1.10876.1.6.1
|
|
psuTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF PsuEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The table for power supply management from CMM perspective."
|
|
::= { powerSupplies 1 }
|
|
|
|
|
|
-- 1.3.6.1.4.1.10876.1.6.1.1
|
|
psuEntry OBJECT-TYPE
|
|
SYNTAX PsuEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The table entry for power supply management."
|
|
INDEX { psuIndex }
|
|
::= { psuTable 1 }
|
|
|
|
|
|
PsuEntry ::=
|
|
SEQUENCE {
|
|
psuIndex
|
|
Integer32,
|
|
psuSlotID
|
|
Integer32,
|
|
psuPresence
|
|
INTEGER,
|
|
psuName
|
|
OCTET STRING,
|
|
psuModel
|
|
OCTET STRING,
|
|
psuPowerStatus
|
|
INTEGER,
|
|
psuTemperature
|
|
OCTET STRING,
|
|
psuFAN1Speed
|
|
Integer32,
|
|
psuFAN2Speed
|
|
Integer32,
|
|
psuFAN3Speed
|
|
Integer32,
|
|
psuFAN4Speed
|
|
Integer32,
|
|
psuACInVoltage
|
|
Integer32,
|
|
psuMaxWatt
|
|
Integer32,
|
|
psuACInCurrent
|
|
OCTET STRING,
|
|
psuDCOutCurrent
|
|
OCTET STRING,
|
|
psuCurrentPwrUsage
|
|
OCTET STRING,
|
|
psuFWVersion
|
|
OCTET STRING,
|
|
psuFRUVersion
|
|
OCTET STRING
|
|
}
|
|
|
|
-- 1.3.6.1.4.1.10876.1.6.1.1.1
|
|
psuIndex OBJECT-TYPE
|
|
SYNTAX Integer32 (1..65535)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The index for power supply table."
|
|
::= { psuEntry 1 }
|
|
|
|
|
|
-- 1.3.6.1.4.1.10876.1.6.1.1.2
|
|
psuSlotID OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The indication for power supply slot index."
|
|
::= { psuEntry 2 }
|
|
|
|
|
|
-- 1.3.6.1.4.1.10876.1.6.1.1.3
|
|
psuPresence OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
notPresent(0),
|
|
present(1)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The indication for power supply presence."
|
|
::= { psuEntry 3 }
|
|
|
|
|
|
-- 1.3.6.1.4.1.10876.1.6.1.1.4
|
|
psuName OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The indication for power supply name."
|
|
::= { psuEntry 4 }
|
|
|
|
|
|
-- 1.3.6.1.4.1.10876.1.6.1.1.5
|
|
psuModel OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (0..16))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The indication for power supply model name."
|
|
::= { psuEntry 5 }
|
|
|
|
|
|
-- 1.3.6.1.4.1.10876.1.6.1.1.6
|
|
psuPowerStatus OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
powerOff(0),
|
|
powerOn(1),
|
|
powerFailure(2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The indication for power supply power status."
|
|
::= { psuEntry 6 }
|
|
|
|
|
|
-- 1.3.6.1.4.1.10876.1.6.1.1.7
|
|
psuTemperature OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The indication for power supply temperature."
|
|
::= { psuEntry 7 }
|
|
|
|
|
|
-- 1.3.6.1.4.1.10876.1.6.1.1.8
|
|
psuFAN1Speed OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "RPM"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The indication for power supply FAN1 speed (RPM)."
|
|
::= { psuEntry 8 }
|
|
|
|
|
|
-- 1.3.6.1.4.1.10876.1.6.1.1.9
|
|
psuFAN2Speed OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "RPM"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The indication for power supply FAN2 speed (RPM)."
|
|
::= { psuEntry 9 }
|
|
|
|
|
|
-- 1.3.6.1.4.1.10876.1.6.1.1.10
|
|
psuFAN3Speed OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "RPM"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The indication for power supply FAN3(if exists) speed (RPM)."
|
|
::= { psuEntry 10 }
|
|
|
|
|
|
-- 1.3.6.1.4.1.10876.1.6.1.1.11
|
|
psuFAN4Speed OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "RPM"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The indication for power supply FAN4(if exists) speed (RPM)."
|
|
::= { psuEntry 11 }
|
|
|
|
|
|
-- 1.3.6.1.4.1.10876.1.6.1.1.12
|
|
psuACInVoltage OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "V"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The indication for power supply AC Input Voltage."
|
|
::= { psuEntry 12 }
|
|
|
|
|
|
-- 1.3.6.1.4.1.10876.1.6.1.1.13
|
|
psuMaxWatt OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "W"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The indication for power supply MAX Watts."
|
|
::= { psuEntry 13 }
|
|
|
|
|
|
-- 1.3.6.1.4.1.10876.1.6.1.1.14
|
|
psuACInCurrent OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
UNITS "A"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The indication for power supply AC Input Current."
|
|
::= { psuEntry 14 }
|
|
|
|
|
|
-- 1.3.6.1.4.1.10876.1.6.1.1.15
|
|
psuDCOutCurrent OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
UNITS "A"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The indication for power supply DC Out Current."
|
|
::= { psuEntry 15 }
|
|
|
|
|
|
-- 1.3.6.1.4.1.10876.1.6.1.1.16
|
|
psuCurrentPwrUsage OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
UNITS "%"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The indication for power supply Current Power Usage."
|
|
::= { psuEntry 16 }
|
|
|
|
|
|
-- 1.3.6.1.4.1.10876.1.6.1.1.17
|
|
psuFWVersion OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The indication for power supply F/W version."
|
|
::= { psuEntry 17 }
|
|
|
|
|
|
-- 1.3.6.1.4.1.10876.1.6.1.1.18
|
|
psuFRUVersion OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The indication for power supply FRU version."
|
|
::= { psuEntry 18 }
|
|
|
|
|
|
-- 1.3.6.1.4.1.10876.1.6.2
|
|
pwrGrpConsumption OBJECT-GROUP
|
|
OBJECTS { pwrTotalPower, pwrBladeReserved, pwrPeripheralReserved,
|
|
pwrAvailablePower, pwrCurrentMaxTemp,
|
|
|
|
pwrCurrentMaxTempModule }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The group for power consumption."
|
|
::= { powerSupplies 2 }
|
|
|
|
|
|
-- 1.3.6.1.4.1.10876.1.6.3
|
|
pwrTotalPower OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The indication for total power of all available power supplies."
|
|
::= { powerSupplies 3 }
|
|
|
|
|
|
-- 1.3.6.1.4.1.10876.1.6.4
|
|
pwrBladeReserved OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The indication for blade reserved power."
|
|
::= { powerSupplies 4 }
|
|
|
|
|
|
-- 1.3.6.1.4.1.10876.1.6.5
|
|
pwrPeripheralReserved OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The indication for peripheral reserved power."
|
|
::= { powerSupplies 5 }
|
|
|
|
|
|
-- 1.3.6.1.4.1.10876.1.6.6
|
|
pwrAvailablePower OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The indication for available power."
|
|
::= { powerSupplies 6 }
|
|
|
|
|
|
-- 1.3.6.1.4.1.10876.1.6.7
|
|
pwrCurrentMaxTemp OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The indication for current MAX temperature within all available
|
|
modules."
|
|
::= { powerSupplies 7 }
|
|
|
|
|
|
-- 1.3.6.1.4.1.10876.1.6.8
|
|
pwrCurrentMaxTempModule OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The indication for the module with current MAX temperature."
|
|
::= { powerSupplies 8 }
|
|
|
|
|
|
-- 1.3.6.1.4.1.10876.1.6.9
|
|
pwrGrpPSURedundancy OBJECT-GROUP
|
|
OBJECTS { pwrRedundancy }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The group for power supply redundancy."
|
|
::= { powerSupplies 9 }
|
|
|
|
|
|
-- 1.3.6.1.4.1.10876.1.6.10
|
|
pwrRedundancy OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
pwrRedundancyDisabled(0),
|
|
pwrRedundancyEnabled(1)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The indication for power redundancy policy. Enabled -
|
|
PSU Redundancy (7+1)."
|
|
::= { powerSupplies 10 }
|
|
|
|
|
|
-- 1.3.6.1.4.1.10876.1.6.11
|
|
pwrGrpPSUFanCtrl OBJECT-GROUP
|
|
OBJECTS { pwrPSUFanCtrl, pwrPSUFanSpdCtrl }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The group for power supply FAN control."
|
|
::= { powerSupplies 11 }
|
|
|
|
|
|
-- 1.3.6.1.4.1.10876.1.6.12
|
|
pwrPSUFanCtrl OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
userCtrl(0),
|
|
autoCtrl(1)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The indication for power supply FAN control policy."
|
|
::= { powerSupplies 12 }
|
|
|
|
|
|
-- 1.3.6.1.4.1.10876.1.6.13
|
|
pwrPSUFanSpdCtrl OBJECT-TYPE
|
|
SYNTAX Integer32 (1..4)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The indication for power supply FAN speed control when pwrPSUFanCtrl is
|
|
in userCtrl mode."
|
|
::= { powerSupplies 13 }
|
|
|
|
|
|
-- CMM Management section
|
|
-- 1.3.6.1.4.1.10876.1.7
|
|
cmms OBJECT IDENTIFIER ::= { cmm 7 }
|
|
|
|
|
|
-- 1.3.6.1.4.1.10876.1.7.1
|
|
cmmTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF CmmEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The table for CMM management."
|
|
::= { cmms 1 }
|
|
|
|
|
|
-- 1.3.6.1.4.1.10876.1.7.1.1
|
|
cmmEntry OBJECT-TYPE
|
|
SYNTAX CmmEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The table entry for CMM management."
|
|
INDEX { cmmIndex }
|
|
::= { cmmTable 1 }
|
|
|
|
|
|
CmmEntry ::=
|
|
SEQUENCE {
|
|
cmmIndex
|
|
Integer32,
|
|
cmmSlot
|
|
Integer32,
|
|
cmmPresence
|
|
INTEGER,
|
|
cmmName
|
|
OCTET STRING,
|
|
cmmRole
|
|
INTEGER,
|
|
cmmIPAddr
|
|
IpAddress,
|
|
cmmStatus
|
|
INTEGER,
|
|
cmmFWVersion
|
|
OCTET STRING,
|
|
cmmFWTag
|
|
OCTET STRING
|
|
}
|
|
|
|
-- 1.3.6.1.4.1.10876.1.7.1.1.1
|
|
cmmIndex OBJECT-TYPE
|
|
SYNTAX Integer32 (1..65535)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The index for CMM table."
|
|
::= { cmmEntry 1 }
|
|
|
|
|
|
-- 1.3.6.1.4.1.10876.1.7.1.1.2
|
|
cmmSlot OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The indication for CMM slot index."
|
|
::= { cmmEntry 2 }
|
|
|
|
|
|
-- 1.3.6.1.4.1.10876.1.7.1.1.3
|
|
cmmPresence OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
notPresent(0),
|
|
present(1)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The indication for CMM presence."
|
|
::= { cmmEntry 3 }
|
|
|
|
|
|
-- 1.3.6.1.4.1.10876.1.7.1.1.4
|
|
cmmName OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The indication for CMM name (user defined)."
|
|
::= { cmmEntry 4 }
|
|
|
|
|
|
-- 1.3.6.1.4.1.10876.1.7.1.1.5
|
|
cmmRole OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
master(0),
|
|
slave(1)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The indication for CMM role (master/slave)."
|
|
::= { cmmEntry 5 }
|
|
|
|
|
|
-- 1.3.6.1.4.1.10876.1.7.1.1.6
|
|
cmmIPAddr OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The indication for CMM IP address."
|
|
::= { cmmEntry 6 }
|
|
|
|
|
|
-- 1.3.6.1.4.1.10876.1.7.1.1.7
|
|
cmmStatus OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
notAvailable(0),
|
|
available(1)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The indication for CMM available status."
|
|
::= { cmmEntry 7 }
|
|
|
|
|
|
-- 1.3.6.1.4.1.10876.1.7.1.1.8
|
|
cmmFWVersion OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The indication for CMM firmware version."
|
|
::= { cmmEntry 8 }
|
|
|
|
|
|
-- 1.3.6.1.4.1.10876.1.7.1.1.9
|
|
cmmFWTag OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The indication for CMM firmware tag."
|
|
::= { cmmEntry 9 }
|
|
|
|
|
|
-- 1.3.6.1.4.1.10876.1.7.2
|
|
cmmOperationMode OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
enterprise(0),
|
|
office(1)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The indication for CMM operation mode (enterprise/office)."
|
|
::= { cmms 2 }
|
|
|
|
|
|
-- 1.3.6.1.4.1.10876.1.7.3
|
|
cmmDateTime OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The indication for CMM date and time. The format must be
|
|
MM/dd/yyyy HH:mm:ss."
|
|
::= { cmms 3 }
|
|
|
|
|
|
-- 1.3.6.1.4.1.10876.1.7.4
|
|
cmmNTPStatus OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
userDefined(0),
|
|
ntpSync(1)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The indication for CMM date and time synchronization mode (user specified
|
|
/NTP server auto sync)."
|
|
::= { cmms 4 }
|
|
|
|
|
|
-- 1.3.6.1.4.1.10876.1.7.5
|
|
cmmNTPServer1 OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The indication for the primary NTP server for CMM."
|
|
::= { cmms 5 }
|
|
|
|
|
|
-- 1.3.6.1.4.1.10876.1.7.6
|
|
cmmNTPServer2 OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The indication for the secondary NTP server for CMM."
|
|
::= { cmms 6 }
|
|
|
|
|
|
-- 1.3.6.1.4.1.10876.1.7.7
|
|
cmmUTCOffset OBJECT-TYPE
|
|
SYNTAX Integer32 (-11..12)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The indication for CMM UTC offset."
|
|
::= { cmms 7 }
|
|
|
|
|
|
-- FRU section
|
|
-- 1.3.6.1.4.1.10876.1.8
|
|
fru OBJECT IDENTIFIER ::= { cmm 8 }
|
|
|
|
|
|
-- 1.3.6.1.4.1.10876.1.8.1
|
|
fruTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF FruEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"The table for FRU of all devices managed by CMM."
|
|
::= { fru 1 }
|
|
|
|
|
|
-- 1.3.6.1.4.1.10876.1.8.1.1
|
|
fruEntry OBJECT-TYPE
|
|
SYNTAX FruEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"The table entry for FRU of all devices managed by CMM."
|
|
INDEX { fruTableIndex }
|
|
::= { fruTable 1 }
|
|
|
|
|
|
FruEntry ::=
|
|
SEQUENCE {
|
|
fruTableIndex
|
|
Integer32,
|
|
fruDeviceType
|
|
INTEGER,
|
|
fruDeviceSlot
|
|
Unsigned32,
|
|
fruDevID
|
|
Unsigned32,
|
|
fruChassisType
|
|
INTEGER,
|
|
fruChassisTypeCode
|
|
Unsigned32,
|
|
fruChassisPN
|
|
OCTET STRING,
|
|
fruChassisSN
|
|
OCTET STRING,
|
|
fruBoardLang
|
|
INTEGER,
|
|
fruBoardLangCode
|
|
Unsigned32,
|
|
fruBoardMfgDatetime
|
|
OCTET STRING,
|
|
fruBoardMfgName
|
|
OCTET STRING,
|
|
fruBoardProdName
|
|
OCTET STRING,
|
|
fruBoardSN
|
|
OCTET STRING,
|
|
fruBoardPN
|
|
OCTET STRING,
|
|
fruProdLang
|
|
INTEGER,
|
|
fruProdLangCode
|
|
Unsigned32,
|
|
fruProdMfgName
|
|
OCTET STRING,
|
|
fruProdProdName
|
|
OCTET STRING,
|
|
fruProdPN
|
|
OCTET STRING,
|
|
fruProdVersion
|
|
OCTET STRING,
|
|
fruProdSN
|
|
OCTET STRING,
|
|
fruProdAssetTag
|
|
OCTET STRING
|
|
}
|
|
|
|
-- 1.3.6.1.4.1.10876.1.8.1.1.1
|
|
fruTableIndex OBJECT-TYPE
|
|
SYNTAX Integer32 (1..65535)
|
|
MAX-ACCESS not-accessible
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"The index for the table for FRU of all devices managed by CMM."
|
|
::= { fruEntry 1 }
|
|
|
|
|
|
-- 1.3.6.1.4.1.10876.1.8.1.1.2
|
|
fruDeviceType OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
cmm(0),
|
|
middlePlane(1),
|
|
switch(2),
|
|
powerSupply(3),
|
|
blade(4)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"The indication for the FRU device type."
|
|
::= { fruEntry 2 }
|
|
|
|
|
|
-- 1.3.6.1.4.1.10876.1.8.1.1.3
|
|
fruDeviceSlot OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"The indication for the FRU device slot."
|
|
::= { fruEntry 3 }
|
|
|
|
|
|
-- 1.3.6.1.4.1.10876.1.8.1.1.4
|
|
fruDevID OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"The indication for the FRU block device ID."
|
|
::= { fruEntry 4 }
|
|
|
|
|
|
-- 1.3.6.1.4.1.10876.1.8.1.1.5
|
|
fruChassisType OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
reserved(0),
|
|
other(1),
|
|
unknown(2),
|
|
desktop(3),
|
|
lowProfileDesktop(4),
|
|
pizzaBox(5),
|
|
miniTower(6),
|
|
tower(7),
|
|
portable(8),
|
|
laptop(9),
|
|
notebook(10),
|
|
handHeld(11),
|
|
dockingStation(12),
|
|
allInOne(13),
|
|
subNotebook(14),
|
|
spaceSaving(15),
|
|
lunchBox(16),
|
|
mainServerChassis(17),
|
|
expansionChassis(18),
|
|
subChassis(19),
|
|
busExpansionChassis(20),
|
|
peripheralChassis(21),
|
|
raidChassis(22),
|
|
rackMountChassis(23)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"The indication for the chassis type defined in FRU specification."
|
|
::= { fruEntry 5 }
|
|
|
|
|
|
-- 1.3.6.1.4.1.10876.1.8.1.1.6
|
|
fruChassisTypeCode OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"The indication for the chassis type code."
|
|
::= { fruEntry 6 }
|
|
|
|
|
|
-- 1.3.6.1.4.1.10876.1.8.1.1.7
|
|
fruChassisPN OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"The indication for the chassis part number."
|
|
::= { fruEntry 7 }
|
|
|
|
|
|
-- 1.3.6.1.4.1.10876.1.8.1.1.8
|
|
fruChassisSN OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"The indication for the chassis serial number."
|
|
::= { fruEntry 8 }
|
|
|
|
|
|
-- 1.3.6.1.4.1.10876.1.8.1.1.9
|
|
fruBoardLang OBJECT-TYPE
|
|
SYNTAX INTEGER { english(0) }
|
|
MAX-ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"The indication for the board language."
|
|
::= { fruEntry 9 }
|
|
|
|
|
|
-- 1.3.6.1.4.1.10876.1.8.1.1.10
|
|
fruBoardLangCode OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"The indication for the board language code."
|
|
::= { fruEntry 10 }
|
|
|
|
|
|
-- 1.3.6.1.4.1.10876.1.8.1.1.11
|
|
fruBoardMfgDatetime OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"The indication for the board manufactory datetime."
|
|
::= { fruEntry 11 }
|
|
|
|
|
|
-- 1.3.6.1.4.1.10876.1.8.1.1.12
|
|
fruBoardMfgName OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"The indication for the board manufactory name."
|
|
::= { fruEntry 12 }
|
|
|
|
|
|
-- 1.3.6.1.4.1.10876.1.8.1.1.13
|
|
fruBoardProdName OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"The indication for the baord product name."
|
|
::= { fruEntry 13 }
|
|
|
|
|
|
-- 1.3.6.1.4.1.10876.1.8.1.1.14
|
|
fruBoardSN OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"The indication for the board serial number."
|
|
::= { fruEntry 14 }
|
|
|
|
|
|
-- 1.3.6.1.4.1.10876.1.8.1.1.15
|
|
fruBoardPN OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"The indication for the board part number."
|
|
::= { fruEntry 15 }
|
|
|
|
|
|
-- 1.3.6.1.4.1.10876.1.8.1.1.16
|
|
fruProdLang OBJECT-TYPE
|
|
SYNTAX INTEGER { english(0) }
|
|
MAX-ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"The indication for the product language."
|
|
::= { fruEntry 16 }
|
|
|
|
|
|
-- 1.3.6.1.4.1.10876.1.8.1.1.17
|
|
fruProdLangCode OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"The indication for the product language code."
|
|
::= { fruEntry 17 }
|
|
|
|
|
|
-- 1.3.6.1.4.1.10876.1.8.1.1.18
|
|
fruProdMfgName OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"The indication for the product manufactory name."
|
|
::= { fruEntry 18 }
|
|
|
|
|
|
-- 1.3.6.1.4.1.10876.1.8.1.1.19
|
|
fruProdProdName OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"The indication for the product name."
|
|
::= { fruEntry 19 }
|
|
|
|
|
|
-- 1.3.6.1.4.1.10876.1.8.1.1.20
|
|
fruProdPN OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"The indication for the product part/model number."
|
|
::= { fruEntry 20 }
|
|
|
|
|
|
-- 1.3.6.1.4.1.10876.1.8.1.1.21
|
|
fruProdVersion OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"The indication for the product version."
|
|
::= { fruEntry 21 }
|
|
|
|
|
|
-- 1.3.6.1.4.1.10876.1.8.1.1.22
|
|
fruProdSN OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"The indication for the product serial number."
|
|
::= { fruEntry 22 }
|
|
|
|
|
|
-- 1.3.6.1.4.1.10876.1.8.1.1.23
|
|
fruProdAssetTag OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"The indication for the product asset tag."
|
|
::= { fruEntry 23 }
|
|
|
|
|
|
-- Virtual Media section
|
|
-- 1.3.6.1.4.1.10876.1.9
|
|
virtualMedias OBJECT IDENTIFIER ::= { cmm 9 }
|
|
|
|
|
|
-- 1.3.6.1.4.1.10876.1.9.1
|
|
floppyActiveImage1 OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Floppy Drive 1 active image information."
|
|
::= { virtualMedias 1 }
|
|
|
|
|
|
-- 1.3.6.1.4.1.10876.1.9.2
|
|
floppyActiveImage2 OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Floppy Drive 2 active image information."
|
|
::= { virtualMedias 2 }
|
|
|
|
|
|
-- 1.3.6.1.4.1.10876.1.9.3
|
|
cdromActiveImage1 OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"CDROM Drive 1 active image information."
|
|
::= { virtualMedias 3 }
|
|
|
|
|
|
-- 1.3.6.1.4.1.10876.1.9.4
|
|
cdromActiveImage2 OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"CDROM Drive 2 active image information."
|
|
::= { virtualMedias 4 }
|
|
|
|
|
|
-- 1.3.6.1.4.1.10876.1.9.5
|
|
drvRedirActiveImage1 OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Drive Redirection Drive 1 active image information."
|
|
::= { virtualMedias 5 }
|
|
|
|
|
|
-- 1.3.6.1.4.1.10876.1.9.6
|
|
drvRedirActiveImage2 OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Drive Redirection Drive 2 active image information."
|
|
::= { virtualMedias 6 }
|
|
|
|
|
|
-- 1.3.6.1.4.1.10876.1.9.7
|
|
drvRedirStatus OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
disabled(0),
|
|
enabled(1)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Drive Redirection enable/disable status."
|
|
::= { virtualMedias 7 }
|
|
|
|
|
|
-- 1.3.6.1.4.1.10876.1.9.8
|
|
drvRedirAccessType OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
readonly(0),
|
|
readwrite(1)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Drive Redirection connections access options (readonly/readwrite)."
|
|
::= { virtualMedias 8 }
|
|
|
|
|
|
-- 1.3.6.1.4.1.10876.1.9.9
|
|
usbEnableWithoutImage OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
disabled(0),
|
|
enabled(1)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Options to enable/disable USB Mass Storage if no image is loaded."
|
|
::= { virtualMedias 9 }
|
|
|
|
|
|
-- KVM Setting section
|
|
-- 1.3.6.1.4.1.10876.1.10
|
|
kvmSettings OBJECT IDENTIFIER ::= { cmm 10 }
|
|
|
|
|
|
-- 1.3.6.1.4.1.10876.1.10.1
|
|
keyboardModel OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
generic104KeyPC(0),
|
|
generic109KeyPC(1),
|
|
appleMacintosh(2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Keyboard Model options."
|
|
::= { kvmSettings 1 }
|
|
|
|
|
|
-- 1.3.6.1.4.1.10876.1.10.2
|
|
keyReleaseTimeoutStatus OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
disabled(0),
|
|
enabled(1)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Key release timeout enable/disable."
|
|
::= { kvmSettings 2 }
|
|
|
|
|
|
-- 1.3.6.1.4.1.10876.1.10.3
|
|
keyReleaseTimeoutInterval OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
time25(0),
|
|
time50(1),
|
|
time100(2),
|
|
time200(3)
|
|
}
|
|
UNITS "msec"
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Key release timeout interval.
|
|
Available options are 25, 50, 100, 200 msec."
|
|
::= { kvmSettings 3 }
|
|
|
|
|
|
-- 1.3.6.1.4.1.10876.1.10.4
|
|
mouseType OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
relative(0),
|
|
absolute(1)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"USB mouse type options.
|
|
Option absolute for Windows (2000 or above) and Mac OS X.
|
|
Option relative for the other OS."
|
|
::= { kvmSettings 4 }
|
|
|
|
|
|
-- 1.3.6.1.4.1.10876.1.10.5
|
|
mouseSpeed OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
auto(0),
|
|
scale1v025(1),
|
|
scale1v050(2),
|
|
scale1v100(3),
|
|
scale1v200(4),
|
|
scale1v400(5)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Mouse speed, only available when mouseType is set to otherOS.
|
|
Available options are Auto, or Fixed Scaling (1:0.25, 1:0.50, 1:1.00, 1:2.
|
|
00, 1:4.00)."
|
|
::= { kvmSettings 5 }
|
|
|
|
|
|
-- Event Log section
|
|
-- 1.3.6.1.4.1.10876.1.11
|
|
eventLogging OBJECT IDENTIFIER ::= { cmm 11 }
|
|
|
|
|
|
-- 1.3.6.1.4.1.10876.1.11.1
|
|
evtGrpLogTargetSettings OBJECT-GROUP
|
|
OBJECTS { evtListLogStatus, evtListEntryPerPage, evtListClearLog,
|
|
evtNFSLogStatus, evtNFSServer,
|
|
|
|
evtNFSShare, evtNFSLogFile, evtSMTPLogStatus, evtSMTPServer,
|
|
evtSMTPRecvEmail,
|
|
|
|
evtSMTPSendEmail, evtSNMPLogStatus, evtSNMPDestIP, evtSNMPCommunity }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The group for event log target settings."
|
|
::= { eventLogging 1 }
|
|
|
|
|
|
-- 1.3.6.1.4.1.10876.1.11.2
|
|
evtListLogStatus OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
disabled(0),
|
|
enabled(1)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Show the event log list enable/diable status."
|
|
::= { eventLogging 2 }
|
|
|
|
|
|
-- 1.3.6.1.4.1.10876.1.11.3
|
|
evtListEntryPerPage OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Entries number per page. Default is 20."
|
|
::= { eventLogging 3 }
|
|
|
|
|
|
-- 1.3.6.1.4.1.10876.1.11.4
|
|
evtListClearLog OBJECT-TYPE
|
|
SYNTAX INTEGER { clear(0) }
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A write only action for clear CMM internal log."
|
|
::= { eventLogging 4 }
|
|
|
|
|
|
-- 1.3.6.1.4.1.10876.1.11.5
|
|
evtNFSLogStatus OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
disabled(0),
|
|
enabled(1)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Event log for NFS logging enable/diable status."
|
|
::= { eventLogging 5 }
|
|
|
|
|
|
-- 1.3.6.1.4.1.10876.1.11.6
|
|
evtNFSServer OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The NFS server for logging."
|
|
::= { eventLogging 6 }
|
|
|
|
|
|
-- 1.3.6.1.4.1.10876.1.11.7
|
|
evtNFSShare OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The NFS share for logging."
|
|
::= { eventLogging 7 }
|
|
|
|
|
|
-- 1.3.6.1.4.1.10876.1.11.8
|
|
evtNFSLogFile OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The NFS log file for logging."
|
|
::= { eventLogging 8 }
|
|
|
|
|
|
-- 1.3.6.1.4.1.10876.1.11.9
|
|
evtSMTPLogStatus OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
disabled(0),
|
|
enabled(1)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Event log for SMTP logging enable/diable status."
|
|
::= { eventLogging 9 }
|
|
|
|
|
|
-- 1.3.6.1.4.1.10876.1.11.10
|
|
evtSMTPServer OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The SMTP server for logging."
|
|
::= { eventLogging 10 }
|
|
|
|
|
|
-- 1.3.6.1.4.1.10876.1.11.11
|
|
evtSMTPRecvEmail OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The receiver email address for SMTP logging."
|
|
::= { eventLogging 11 }
|
|
|
|
|
|
-- 1.3.6.1.4.1.10876.1.11.12
|
|
evtSMTPSendEmail OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The sender email address for SMTP logging."
|
|
::= { eventLogging 12 }
|
|
|
|
|
|
-- 1.3.6.1.4.1.10876.1.11.13
|
|
evtSNMPLogStatus OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
disabled(0),
|
|
enabled(1)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Event log for SNMP logging enable/diable status."
|
|
::= { eventLogging 13 }
|
|
|
|
|
|
-- 1.3.6.1.4.1.10876.1.11.14
|
|
evtSNMPDestIP OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The destination IP address for SNMP logging."
|
|
::= { eventLogging 14 }
|
|
|
|
|
|
-- 1.3.6.1.4.1.10876.1.11.15
|
|
evtSNMPCommunity OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The community name for SNMP logging."
|
|
::= { eventLogging 15 }
|
|
|
|
|
|
|
|
END
|
|
|
|
--
|
|