RUGGEDCOM-SERIAL-MIB DEFINITIONS ::= BEGIN
|
|
|
|
IMPORTS
|
|
MODULE-IDENTITY, OBJECT-IDENTITY,
|
|
OBJECT-TYPE, IpAddress,
|
|
Integer32 FROM SNMPv2-SMI
|
|
OBJECT-GROUP FROM SNMPv2-CONF
|
|
TEXTUAL-CONVENTION FROM SNMPv2-TC
|
|
PortList FROM Q-BRIDGE-MIB
|
|
ruggedcomMgmt FROM RUGGEDCOM-MIB
|
|
InterfaceIndex FROM IF-MIB;
|
|
|
|
rcSerial MODULE-IDENTITY
|
|
LAST-UPDATED "201101111000Z" -- Jan 11, 10:00 EST 2011
|
|
ORGANIZATION "RuggedCom"
|
|
CONTACT-INFO
|
|
"Postal: RuggedCom Inc.
|
|
300 Applewood Crescent
|
|
Concord, Ontario,
|
|
L4K 5C7 Canada
|
|
Tel: 1-905-856-5288
|
|
E-Mail: support@ruggedcom.com"
|
|
|
|
DESCRIPTION
|
|
"RuggedCom MIB for Managing Proprietary Settings for Serial Ports and
|
|
Serial Protocols on RuggedCom Serial Server Devices."
|
|
|
|
REVISION "201101111000Z" -- Jan 11, 10:00 EST 2011
|
|
DESCRIPTION
|
|
"The initial version of RuggedCom MIB for Serial Ports and Serial Protocols."
|
|
|
|
::= { ruggedcomMgmt 6 }
|
|
|
|
-- ---------------------------------------------------------------------- --
|
|
-- Textual Conventions
|
|
-- ---------------------------------------------------------------------- --
|
|
|
|
-- Copied from P-BRIDGE-MIB to avoid compilation of that mib
|
|
-- as ROS does not support P-BRIDGE-MIB
|
|
|
|
EnabledStatus ::= TEXTUAL-CONVENTION
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A simple status value for the object."
|
|
SYNTAX INTEGER {
|
|
enabled(1),
|
|
disabled(2)
|
|
}
|
|
|
|
RcFlowControl ::= TEXTUAL-CONVENTION
|
|
STATUS current
|
|
DESCRIPTION
|
|
"FlowControl setting for serial port."
|
|
SYNTAX INTEGER {
|
|
none(1),
|
|
xonXoff(2)
|
|
}
|
|
|
|
RcSerProtocol ::= TEXTUAL-CONVENTION
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Serial Protocols permitted for RuggedCom Serial Device Servers."
|
|
SYNTAX INTEGER {
|
|
noProtocol(1),
|
|
rawSock(2),
|
|
modbusServer(3),
|
|
modbusClient(4),
|
|
itcsWIN(5),
|
|
itcsTIN(6),
|
|
microlok(7),
|
|
dnp(8),
|
|
dnpRawSock(9),
|
|
mirrorBits(10),
|
|
preemptRawSock(11),
|
|
telnetComport(12)
|
|
}
|
|
|
|
RcTransport ::= TEXTUAL-CONVENTION
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Transport protocol used for IP traffic."
|
|
SYNTAX INTEGER {
|
|
udp(1),
|
|
tcp(2)
|
|
}
|
|
|
|
RcCallDir ::= TEXTUAL-CONVENTION
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Call Direction options for a RuggedCom Serial Server device."
|
|
SYNTAX INTEGER {
|
|
in(0),
|
|
out(1),
|
|
both(2)
|
|
}
|
|
|
|
RcSerPortType ::= TEXTUAL-CONVENTION
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Serial Port Type for RuggedCom Serial Server device."
|
|
SYNTAX INTEGER {
|
|
none(0),
|
|
rs232(1),
|
|
rs485(2),
|
|
rs422(3),
|
|
tpc(4),
|
|
fiber(5)
|
|
}
|
|
|
|
-- ---------------------------------------------------------------------- --
|
|
-- rcSerial subtrees
|
|
-- ---------------------------------------------------------------------- --
|
|
|
|
rcSerialPortParams OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The main subtree for managing Global Serial Port parameters."
|
|
::= { rcSerial 1 }
|
|
|
|
rcMbServer OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The main subtree for managing the Modbus Protocol Server settings
|
|
on RuggedCom serial Devices."
|
|
::= { rcSerial 2 }
|
|
|
|
rcMbClient OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The main subtree for managing the Modbus Protocol Client Settings on
|
|
RuggedCom serial devices."
|
|
::= { rcSerial 3 }
|
|
|
|
rcRawSock OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The main subtree for managing the Raw Socket Protocol Settings on
|
|
RuggedCom serial devices."
|
|
::= { rcSerial 4 }
|
|
|
|
rcPreemptRS OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The main subtree for managing the Preemptive Raw Socket Protocol
|
|
settings on RuggedCom serial devices."
|
|
::= { rcSerial 5 }
|
|
|
|
rcTinAndWin OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The main subtree for managing the TIN and WIN protocol settings on
|
|
RuggedCom serial devices."
|
|
::= { rcSerial 6 }
|
|
|
|
rcMicrolok OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The main subtree for managing the Microlok protocol settings on
|
|
RuggedCom serial devices."
|
|
::= { rcSerial 7 }
|
|
|
|
rcDnp OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Tha main subtree for managing the Dnp protocol settings on
|
|
RuggedCom serial devices."
|
|
::= { rcSerial 8 }
|
|
|
|
rcDnpRs OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Tha main subtree for managing the Dnp over Raw Socket protocol
|
|
settings on RuggedCom serial devices."
|
|
::= { rcSerial 9 }
|
|
|
|
rcMirrorBits OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Tha main subtree for managing the Mirrored Bit protocol settings on
|
|
RuggedCom serial devices."
|
|
::= { rcSerial 10 }
|
|
|
|
rcTelnetComport OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Tha main subtree for managing the TelnetPortComport protocol settings on
|
|
RuggedCom serial devices."
|
|
::= { rcSerial 11 }
|
|
|
|
rcConnStats OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The main subtree for the information about Connection Statistics for
|
|
RuggedCom serial devices."
|
|
::= { rcSerial 15 }
|
|
|
|
rcSerDeviceCmnd OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The main subtree for serial port control commands"
|
|
::= { rcSerial 16}
|
|
|
|
|
|
-- ---------------------------------------------------------------------- --
|
|
-- ---------------------------------------------------------------------- --
|
|
rcSerialConformance OBJECT IDENTIFIER ::= { rcSerial 18 }
|
|
-- rcSerialCompliances OBJECT IDENTIFIER ::= { rcSerialConformance 1 }
|
|
rcSerialGroups OBJECT IDENTIFIER ::= { rcSerialConformance 2 }
|
|
|
|
|
|
-- ---------------------------------------------------------------------- --
|
|
-- Serial Port configuration
|
|
-- ---------------------------------------------------------------------- --
|
|
|
|
rcSerialPortTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF RcSerialPortEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A list of port entries. The number of entries might be
|
|
retreived as the value of object 'rs232Number' from RFC1659."
|
|
::= { rcSerialPortParams 1 }
|
|
|
|
rcSerialPortEntry OBJECT-TYPE
|
|
SYNTAX RcSerialPortEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Status and configuration parameters for a port."
|
|
INDEX {
|
|
rcSerialPortNumber
|
|
}
|
|
::= { rcSerialPortTable 1 }
|
|
|
|
RcSerialPortEntry ::= SEQUENCE {
|
|
rcSerialPortNumber Integer32,
|
|
rcSerialPortIfIndex InterfaceIndex,
|
|
rcSerialProtocol RcSerProtocol,
|
|
rcSerialPortType RcSerPortType,
|
|
rcSerialForceHD INTEGER,
|
|
rcSerialTurnAround Integer32,
|
|
rcSerialPostTxDelay Integer32,
|
|
rcSerialHoldTime Integer32,
|
|
rcSerialDscp Integer32,
|
|
rcSerialRxtoTxDelay Integer32
|
|
}
|
|
|
|
rcSerialPortNumber OBJECT-TYPE
|
|
SYNTAX Integer32 (1..65535)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The physical Serial Port Number of the device for which this Entry
|
|
contains configuration settings."
|
|
::= { rcSerialPortEntry 1 }
|
|
|
|
rcSerialPortIfIndex OBJECT-TYPE
|
|
SYNTAX InterfaceIndex
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of ifIndex for the port. This value is same as
|
|
'rs232PortIndex' which is the index used for 'rs232PortTable'
|
|
in RS-232-MIB."
|
|
::= { rcSerialPortEntry 2 }
|
|
|
|
rcSerialProtocol OBJECT-TYPE
|
|
SYNTAX RcSerProtocol
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A Serial Protocol supported on the Serial Port represented
|
|
by this entry."
|
|
::= { rcSerialPortEntry 3 }
|
|
|
|
rcSerialPortType OBJECT-TYPE
|
|
SYNTAX RcSerPortType
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A Serial Port Type supported on the Serial Port represented
|
|
by this entry."
|
|
::= { rcSerialPortEntry 4 }
|
|
|
|
rcSerialForceHD OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
on(1),
|
|
off(2),
|
|
notApplicable(3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Enables forcing half duplex mode of operation on the Serial Port.
|
|
|
|
While sending data out of the serial port all received data are ignored.
|
|
This mode of operation is available only on ports that operate in full
|
|
duplex mode"
|
|
::= { rcSerialPortEntry 5 }
|
|
|
|
rcSerialTurnAround OBJECT-TYPE
|
|
SYNTAX Integer32(0..1000 )
|
|
UNITS "milliseconds"
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The amount of delay between the transmission of individual messages
|
|
out of the serial port.
|
|
|
|
For 'rcSerialProtocol' object value modbusServer(3) this value must be non-zero.
|
|
It represents delay between sending a brodcast message and the next poll
|
|
out of serial port, because RTUs do not reply to a broadcast, so enough
|
|
time must be ensured to process it."
|
|
::= { rcSerialPortEntry 6 }
|
|
|
|
rcSerialPostTxDelay OBJECT-TYPE
|
|
SYNTAX Integer32(0..15 )
|
|
UNITS "bits"
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of bits needed to generate required delay with configured
|
|
baudrate('rs232PortOutSpeed') after the last bit of the packet was
|
|
sent out before serial UART starts listening to the RX line .
|
|
|
|
This value is relevant for RS485 interface only with 'rs232PortType'
|
|
equals other(1)."
|
|
::= { rcSerialPortEntry 7 }
|
|
|
|
rcSerialHoldTime OBJECT-TYPE
|
|
SYNTAX Integer32(0..15000)
|
|
UNITS "milliseconds"
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The maximum amount of time in ms that serial packet can be held in the
|
|
queue before being sent to the serial line.
|
|
|
|
Time is measured from the moment the packet is received from the IP
|
|
layer."
|
|
::= { rcSerialPortEntry 8 }
|
|
|
|
rcSerialDscp OBJECT-TYPE
|
|
SYNTAX Integer32(0..63)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of DS byte to be set in the IP header.
|
|
|
|
DS byte setting is supported in the egress direction only."
|
|
::= { rcSerialPortEntry 9 }
|
|
|
|
rcSerialRxtoTxDelay OBJECT-TYPE
|
|
SYNTAX Integer32(0..1000)
|
|
UNITS "milliseconds"
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The minimum amount of time in ms that the transmission of a new
|
|
message should delay after the last message is received through the
|
|
serial port.
|
|
|
|
This parameter is useful, especially for the half duplex transmission
|
|
mode, such as two-wire RS485 serial protocol.
|
|
It ensures that the connected device gets enough time to turn off
|
|
its transmitter and to turn on its receiver, so that it can receive
|
|
next message without a single bit loss."
|
|
::= { rcSerialPortEntry 10 }
|
|
|
|
-- ---------------------------------------------------------------------- --
|
|
-- Modbus Server configuration
|
|
-- ---------------------------------------------------------------------- --
|
|
rcMbServerTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF RcMbServerEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This table provides configuration options for the ports when
|
|
'rcSerialProtocol'equals modbusServer(3)."
|
|
::= { rcMbServer 1 }
|
|
|
|
rcMbServerEntry OBJECT-TYPE
|
|
SYNTAX RcMbServerEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"List of all the configuration options for a port for which
|
|
'rcSerialProtocol' equals modbusServer(3)."
|
|
INDEX { rcMbServerPort }
|
|
::= { rcMbServerTable 1 }
|
|
|
|
RcMbServerEntry ::= SEQUENCE {
|
|
rcMbServerPort Integer32,
|
|
rcMbServerRespTimer Integer32,
|
|
rcMbServerAuxTcpPort Integer32,
|
|
rcMbServerSendExcep EnabledStatus,
|
|
rcMbServerLinkStats EnabledStatus
|
|
}
|
|
|
|
rcMbServerPort OBJECT-TYPE
|
|
SYNTAX Integer32 (1..65535)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The physical Serial Port Number for which this Entry contains the
|
|
Modbus Server Protocol configuration settings."
|
|
::= { rcMbServerEntry 1 }
|
|
|
|
rcMbServerRespTimer OBJECT-TYPE
|
|
SYNTAX Integer32(50..10000)
|
|
UNITS "milliseconds"
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The allowable time to wait for the RTU to start to respond."
|
|
::= { rcMbServerEntry 2 }
|
|
|
|
rcMbServerAuxTcpPort OBJECT-TYPE
|
|
SYNTAX Integer32(1024..65535)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The alternative TCP port number where a 'rcMbServerPort' may listen
|
|
to incoming TCP conncetions.
|
|
|
|
Note:TCP Modbus Server always listens on TCP port 502.
|
|
So this parameter allows the RuggedCom serial device to accept
|
|
TCP Modbus Protocol connections request on both TCP ports."
|
|
::= { rcMbServerEntry 3 }
|
|
|
|
rcMbServerSendExcep OBJECT-TYPE
|
|
SYNTAX EnabledStatus
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Allows the RuggedCom Serial Devices to enable or disable sending TCP
|
|
Modbus exception back to the master if response has not been
|
|
received from the RTU within expected time."
|
|
::= { rcMbServerEntry 4 }
|
|
|
|
rcMbServerLinkStats OBJECT-TYPE
|
|
SYNTAX EnabledStatus
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Enables links statistics collection."
|
|
::= { rcMbServerEntry 5 }
|
|
|
|
-- ---------------------------------------------------------------------- --
|
|
-- Modbus Client configuration
|
|
-- ---------------------------------------------------------------------- --
|
|
rcMbClientIPPort OBJECT-TYPE
|
|
SYNTAX Integer32(1..65535)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A remote port number to which protocol connection manager sends TCP
|
|
connection requests."
|
|
::= { rcMbClient 1}
|
|
|
|
rcMbClientFwdExcp OBJECT-TYPE
|
|
SYNTAX EnabledStatus
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Enables forwarding exception messages to the Master as exception
|
|
codes 10 (no path) or 11 (no response).
|
|
|
|
When the Master polls for an unconfigured RTU or the remote Modbus
|
|
Server receives a poll for an RTU which is not configured or is timing
|
|
out, it returns an exception message.
|
|
|
|
This object should be set to 'disabled(2)' if Master does not support
|
|
exceptions but recognizes failure by time-out when waiting for
|
|
response."
|
|
::= { rcMbClient 2}
|
|
|
|
rcMbClientLinkStats OBJECT-TYPE
|
|
SYNTAX EnabledStatus
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Enables link statistics collection."
|
|
::= { rcMbClient 3}
|
|
|
|
rcMbClientDscp OBJECT-TYPE
|
|
SYNTAX Integer32(0..63)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of DS byte to be set in the IP header.
|
|
|
|
DS byte setting is supported in the egress direction only."
|
|
::= { rcMbClient 4}
|
|
|
|
-- ---------------------------------------------------------------------- --
|
|
-- RawSocket configuration
|
|
-- ---------------------------------------------------------------------- --
|
|
rcRawSockTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF RcRawSockEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This table represents the entries for ports configured for Raw Socket
|
|
serial protocol on RuggedCom serial devices."
|
|
::= { rcRawSock 1 }
|
|
|
|
rcRawSockEntry OBJECT-TYPE
|
|
SYNTAX RcRawSockEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"List of all the configuration options available for a port configured
|
|
for Raw Socket serial protocol on Ruggedcom serial devices."
|
|
INDEX { rcRawSockPort }
|
|
::= { rcRawSockTable 1 }
|
|
|
|
RcRawSockEntry ::= SEQUENCE {
|
|
rcRawSockPort Integer32,
|
|
rcRawSockPackChar Integer32,
|
|
rcRawSockPackTimer Integer32,
|
|
rcRawSockPackSize Integer32,
|
|
rcRawSockFlowControl RcFlowControl,
|
|
rcRawSockTransport RcTransport,
|
|
rcRawSockCallDir RcCallDir,
|
|
rcRawSockMaxConn Integer32,
|
|
rcRawSockLocPort Integer32,
|
|
rcRawSockRemPort Integer32,
|
|
rcRawSockIpAdd IpAddress,
|
|
rcRawSockLinkStats EnabledStatus
|
|
}
|
|
|
|
rcRawSockPort OBJECT-TYPE
|
|
SYNTAX Integer32 (1..65535)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The physical Serial Port Number for which this Entry contains
|
|
the Raw Socket serial protocol configuration settings."
|
|
::= { rcRawSockEntry 1 }
|
|
|
|
rcRawSockPackChar OBJECT-TYPE
|
|
SYNTAX Integer32(0..256)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The character that can be used to force forwarding of accumulated
|
|
data to the network.
|
|
|
|
If a packetization character is not configured - object is set to the
|
|
value of '256', accumulated data will be forwarded based upon the
|
|
paketization timeout parameter which is the value set for object
|
|
rcRawSockPackTimer."
|
|
::= { rcRawSockEntry 2 }
|
|
|
|
rcRawSockPackTimer OBJECT-TYPE
|
|
SYNTAX Integer32(3..1000)
|
|
UNITS "milliseconds"
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The delay in ms from the last received character until when data is
|
|
forwarded."
|
|
::= { rcRawSockEntry 3 }
|
|
|
|
rcRawSockPackSize OBJECT-TYPE
|
|
SYNTAX Integer32(64..1401)
|
|
UNITS "bytes"
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The maximum number of bytes received from serial port to be
|
|
forwarded."
|
|
::= { rcRawSockEntry 4 }
|
|
|
|
rcRawSockFlowControl OBJECT-TYPE
|
|
SYNTAX RcFlowControl
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The type of FlowControl to be used on the port."
|
|
::= { rcRawSockEntry 5 }
|
|
|
|
rcRawSockTransport OBJECT-TYPE
|
|
SYNTAX RcTransport
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A transport protocol used for IP traffic for protocol on this port."
|
|
::= { rcRawSockEntry 6 }
|
|
|
|
rcRawSockCallDir OBJECT-TYPE
|
|
SYNTAX RcCallDir
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Defines following:
|
|
- whether to accept an incoming connection 'in(0)' or
|
|
- to place an outgoing connection 'out(1)' or
|
|
- to place an outgoing connection and wait for incomming 'both(2)'
|
|
|
|
Note: This parameter is applicable only for TCP transport."
|
|
::= { rcRawSockEntry 7 }
|
|
|
|
rcRawSockMaxConn OBJECT-TYPE
|
|
SYNTAX Integer32(1..64)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The maximum number of allowed incoming TCP connections."
|
|
::= { rcRawSockEntry 8 }
|
|
|
|
rcRawSockLocPort OBJECT-TYPE
|
|
SYNTAX Integer32(1..65535)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The local IP port to listen to an incoming TCP connection or UDP
|
|
datagrams."
|
|
::= { rcRawSockEntry 9 }
|
|
|
|
rcRawSockRemPort OBJECT-TYPE
|
|
SYNTAX Integer32(1..65535)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The remote IP port to use when placing an outgoing connection."
|
|
::= { rcRawSockEntry 10 }
|
|
|
|
rcRawSockIpAdd OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Defines the IpAddress based on the following:
|
|
- For outgoing TCP connection (client) 'rcRawSockCallDir' is 'out(2)'
|
|
this is the remote IP address to communicate with.
|
|
- For incoming TCP connection (server), 'rcRawSockCallDir' is
|
|
'out(2)' or 'both(3)' this is the local interface IP address to
|
|
listen to the local port for connection request.
|
|
- For both, outgoing and incoming connections enabled
|
|
(client or server), 'rcRawSockCallDir' is 'both(3)' this is the
|
|
remote IP address where to place an outgoing TCP connection request
|
|
or from which to accept calls.
|
|
- For UDP transport address of interface to listen to UDP datagrams."
|
|
::= { rcRawSockEntry 11 }
|
|
|
|
rcRawSockLinkStats OBJECT-TYPE
|
|
SYNTAX EnabledStatus
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Enables links statistics collection for RawSocket on this port."
|
|
::= { rcRawSockEntry 12 }
|
|
|
|
-- ---------------------------------------------------------------------- --
|
|
-- Preemptiv RawSocket
|
|
-- ---------------------------------------------------------------------- --
|
|
rcPreemptRSTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF RcPreemptRSEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This Table defines the configuration options available for ports
|
|
configured for PreEmptive Raw Socket serial protocol."
|
|
::= { rcPreemptRS 1 }
|
|
|
|
rcPreemptRSEntry OBJECT-TYPE
|
|
SYNTAX RcPreemptRSEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A list of port entries with configuration options for ports configured
|
|
for PreEmptive Raw Socket protocol."
|
|
INDEX { rcPreemptRSPort }
|
|
::= { rcPreemptRSTable 1 }
|
|
|
|
RcPreemptRSEntry ::= SEQUENCE {
|
|
rcPreemptRSPort Integer32,
|
|
rcPreemptRSPackChar Integer32,
|
|
rcPreemptRSPackTimer Integer32,
|
|
rcPreemptRSPackSize Integer32,
|
|
rcPreemptRSFlowControl RcFlowControl,
|
|
rcPreemptRSLocPort Integer32,
|
|
rcPreemptRSRemPort Integer32,
|
|
rcPreemptRSIpAdd IpAddress,
|
|
rcPreemptRSLinkStats EnabledStatus,
|
|
rcPreemptRSDynPackChar Integer32,
|
|
rcPreemptRSDynPackTimer Integer32,
|
|
rcPreemptRSDynTimeout Integer32
|
|
}
|
|
|
|
rcPreemptRSPort OBJECT-TYPE
|
|
SYNTAX Integer32(1..65535)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The physical Serial Port Number for which this Entry contains
|
|
the Preemptive Raw Socket serial protocol configuration settings."
|
|
::= { rcPreemptRSEntry 1 }
|
|
|
|
rcPreemptRSPackChar OBJECT-TYPE
|
|
SYNTAX Integer32(0..256)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The character that can be used to force forwarding of accumulated
|
|
data to the network.
|
|
|
|
If a packetization character is not configured - object is set to the
|
|
value of '256', accumulated data will be forwarded based upon the
|
|
paketization timeout parameter which is the value set for object
|
|
rcPreemptRSPackTimer."
|
|
::= { rcPreemptRSEntry 2 }
|
|
|
|
rcPreemptRSPackTimer OBJECT-TYPE
|
|
SYNTAX Integer32(3..1000)
|
|
UNITS "milliseconds"
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The delay in milliseconds from the last received character until
|
|
when data is forwarded."
|
|
::= { rcPreemptRSEntry 3 }
|
|
|
|
rcPreemptRSPackSize OBJECT-TYPE
|
|
SYNTAX Integer32(64..1400)
|
|
UNITS "bytes"
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The Maximum number of bytes received from serial port to be packed
|
|
in one IP packet."
|
|
::= { rcPreemptRSEntry 4 }
|
|
|
|
rcPreemptRSFlowControl OBJECT-TYPE
|
|
SYNTAX RcFlowControl
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The type of FlowControl to be used on the port."
|
|
::= { rcPreemptRSEntry 5 }
|
|
|
|
rcPreemptRSLocPort OBJECT-TYPE
|
|
SYNTAX Integer32(1..65535)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The local IP port to listen to an incoming TCP connection or UDP
|
|
datagrams."
|
|
::= { rcPreemptRSEntry 6 }
|
|
|
|
rcPreemptRSRemPort OBJECT-TYPE
|
|
SYNTAX Integer32(1..65535)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The remote TCP port to use when placing an outgoing connection."
|
|
::= { rcPreemptRSEntry 7 }
|
|
|
|
rcPreemptRSIpAdd OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Defines the IpAddress based on the following:
|
|
- For outgoing TCP connection (client) 'rcRawSockCallDir' is 'out(2)'
|
|
this is the remote IP address to communicate with.
|
|
- For incoming TCP connection (server), 'rcRawSockCallDir' is
|
|
'out(2)' or 'both(3)' this is the local interface IP address to
|
|
listen to the local port for connection request.
|
|
- For both, outgoing and incoming connections enabled
|
|
(client or server), 'rcRawSockCallDir' is 'both(3)' this is the
|
|
remote IP address where to place an outgoing TCP connection request
|
|
or from which to accept calls."
|
|
::= { rcPreemptRSEntry 8 }
|
|
|
|
rcPreemptRSLinkStats OBJECT-TYPE
|
|
SYNTAX EnabledStatus
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Enables links statistics collection."
|
|
::= { rcPreemptRSEntry 9 }
|
|
|
|
rcPreemptRSDynPackChar OBJECT-TYPE
|
|
SYNTAX Integer32(0..256)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The character that can be used to force forwarding of accumulated data
|
|
to the network for connection to dynamic master.
|
|
|
|
If a packetization character is not configured, accumulated data will
|
|
be forwarded based upon the packetization timeout parameter
|
|
'rcPreemptRSDynPackTimer'."
|
|
::= { rcPreemptRSEntry 10 }
|
|
|
|
rcPreemptRSDynPackTimer OBJECT-TYPE
|
|
SYNTAX Integer32(3..1000)
|
|
UNITS "milliseconds"
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The delay in milliseconds from the last received character until when
|
|
data is forwarded to the dynamic master."
|
|
::= { rcPreemptRSEntry 11 }
|
|
|
|
rcPreemptRSDynTimeout OBJECT-TYPE
|
|
SYNTAX Integer32(10..3600)
|
|
UNITS "seconds"
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The time in seconds that is allowed to dynamic master to be idle
|
|
before it's connection is closed.
|
|
The protocol listens to the socket open to dymamic master, and if
|
|
no data are received within this time, conneciton will be closed."
|
|
::= { rcPreemptRSEntry 12 }
|
|
|
|
-- ---------------------------------------------------------------------- --
|
|
-- TIN and WIN protocols configuraiton
|
|
-- ---------------------------------------------------------------------- --
|
|
|
|
rcTinAndWinTinMode OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
tin1(1),
|
|
tin2(2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The TIN Protocol running mode"
|
|
::= { rcTinAndWin 1}
|
|
|
|
rcTinAndWinTinTrans OBJECT-TYPE
|
|
SYNTAX RcTransport
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A transport protocol used for IP traffic for TIN protocol."
|
|
::= { rcTinAndWin 2}
|
|
|
|
rcTinAndWinWinTrans OBJECT-TYPE
|
|
SYNTAX RcTransport
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A transport protocol used for IP traffic for WIN protocol."
|
|
::= { rcTinAndWin 3}
|
|
|
|
rcTinAndWinTinIpPort OBJECT-TYPE
|
|
SYNTAX Integer32(1024..65535)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A local port number on which TIN protocol listens to connections or
|
|
UDP datagrams."
|
|
::= { rcTinAndWin 4}
|
|
|
|
rcTinAndWinWinIpPort OBJECT-TYPE
|
|
SYNTAX Integer32(1024..65535)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A local port number on which WIN protocol listens to connections or
|
|
UDP datagrams."
|
|
::= { rcTinAndWin 5}
|
|
|
|
rcTinAndWinMsgAgingTime OBJECT-TYPE
|
|
SYNTAX Integer32(0..3600)
|
|
UNITS "seconds"
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Aging time for TIN mode2 messages.
|
|
|
|
The feature is disabled if the value of this object is '0'.
|
|
|
|
When the feature is enabled, any TIN mode2 message received will be
|
|
stored in an internal table. So if the same message is received
|
|
within the time window specified by this parameter, the new message is
|
|
considered duplicate, and thus discarded."
|
|
::= { rcTinAndWin 6}
|
|
|
|
rcTinAndWinAddrAgingTime OBJECT-TYPE
|
|
SYNTAX Integer32(1..1000)
|
|
UNITS "milliseconds"
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The time of communication inactivity in milliseconds after which a
|
|
learned TIN address is removed from the dynamic device address table.
|
|
|
|
Entries in Link Statistics Table with the aged address will be kept
|
|
until statistics is cleared."
|
|
::= { rcTinAndWin 7}
|
|
|
|
rcTinAndWinBroadCastAddr OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
static(1),
|
|
dynamic(2),
|
|
staticAndDynamic(3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The device address table in which addresses will be found for broadcast
|
|
messages."
|
|
::= { rcTinAndWin 8}
|
|
|
|
rcTinAndWinUniAddr OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
static(1),
|
|
dynamic(2),
|
|
staticAndDynamic(3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The device address table in which addresses will be found for unicast
|
|
messages."
|
|
::= { rcTinAndWin 9}
|
|
|
|
rcTinAndWinLinkStats OBJECT-TYPE
|
|
SYNTAX EnabledStatus
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Enables links statistics collection for TIN and WIN protocols."
|
|
::= { rcTinAndWin 10}
|
|
|
|
rcTinAndWinWinDscp OBJECT-TYPE
|
|
SYNTAX Integer32(0..63)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of DS byte to be set in the IP header.
|
|
|
|
DS byte setting is supported in the egress direction only."
|
|
::= { rcTinAndWin 11}
|
|
|
|
rcTinAndWinTinDscp OBJECT-TYPE
|
|
SYNTAX Integer32(0..63)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of DS byte to be set in the IP header.
|
|
|
|
DS byte setting is supported in the egress direction only."
|
|
::= { rcTinAndWin 12}
|
|
|
|
|
|
-- ---------------------------------------------------------------------- --
|
|
-- Microlok protocol configuration
|
|
-- ---------------------------------------------------------------------- --
|
|
rcMicrolokTransport OBJECT-TYPE
|
|
SYNTAX RcTransport
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A transport protocol used for IP traffic for Microloc protocol."
|
|
::= {rcMicrolok 1}
|
|
|
|
rcMicrolokIpPort OBJECT-TYPE
|
|
SYNTAX Integer32(1024..65535)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A local port number on which Microloc protocol listens to connections
|
|
or UDP datagrams."
|
|
::= {rcMicrolok 2}
|
|
|
|
rcMicrolokLinkStats OBJECT-TYPE
|
|
SYNTAX EnabledStatus
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Enables links statistics collection."
|
|
::= {rcMicrolok 3}
|
|
|
|
rcMicrolokDscp OBJECT-TYPE
|
|
SYNTAX Integer32(0..63)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of DS byte to be set in the IP header.
|
|
|
|
DS byte setting is supported in the egress direction only."
|
|
::= {rcMicrolok 4}
|
|
|
|
-- ---------------------------------------------------------------------- --
|
|
-- DNP protocol configuration
|
|
-- ---------------------------------------------------------------------- --
|
|
|
|
rcDnpTransport OBJECT-TYPE
|
|
SYNTAX RcTransport
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A transport protocol used for IP traffic for DNP protocol."
|
|
::= {rcDnp 1}
|
|
|
|
rcDnpIpPort OBJECT-TYPE
|
|
SYNTAX Integer32(1024..65535)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A local port number on which DNP protocol listens to connections or
|
|
UDP datagrams."
|
|
::= { rcDnp 2 }
|
|
|
|
rcDnpLearning OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Enable or disable address learning.
|
|
|
|
Learning can be disabled, or enabled on management IP interface, or
|
|
enabled on the interface with specific IP address. If learning is
|
|
enabled and remote address is not known, UDP broadcast message will be
|
|
sent and source addresses will be learned on devices that run DNP
|
|
protocol. If local address is not known, message will be sent to all
|
|
serial ports running DNP protocol. Local addresses will be learned from
|
|
local responses. If TCP transport is configured, connection will be
|
|
established to the devices with the corresponding IP address."
|
|
::= { rcDnp 3 }
|
|
|
|
rcDnpAgingTimer OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The time of communication inactivity after which a learned DNP address
|
|
is removed from the device address table.
|
|
|
|
Entries in Link Statistics Table with the aged address will be kept
|
|
until statistics is cleared."
|
|
::= { rcDnp 4 }
|
|
|
|
rcDnpLinkStats OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Enables links statistics collection."
|
|
::= { rcDnp 5 }
|
|
|
|
rcDnpDscp OBJECT-TYPE
|
|
SYNTAX Integer32(0..63)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of DS byte to be set in the IP header.
|
|
|
|
DS byte setting is supported in the egress direction only."
|
|
::= { rcDnp 6 }
|
|
|
|
-- ---------------------------------------------------------------------- --
|
|
-- DNP over RawSocket configuration
|
|
-- ---------------------------------------------------------------------- --
|
|
|
|
|
|
rcDnpRsTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF RcDnpRsEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This table represents the set of parameters provide the ability to
|
|
configure DNP over RawSocket protocol settings for serial ports.
|
|
If no ports appear, then the DNP over RawSocket protocol must first be
|
|
assigned to port(s)"
|
|
::= { rcDnpRs 1}
|
|
|
|
rcDnpRsEntry OBJECT-TYPE
|
|
SYNTAX RcDnpRsEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"List of ports with configuration parameters for DNP over RawSocket
|
|
serial protocol ."
|
|
INDEX { rcDnpRsPort }
|
|
::= { rcDnpRsTable 1 }
|
|
|
|
RcDnpRsEntry::= SEQUENCE {
|
|
rcDnpRsPort Integer32,
|
|
rcDnpRsCalllDir RcCallDir,
|
|
rcDnpRsTransport RcTransport,
|
|
rcDnpRsMaxConns Integer32,
|
|
rcDnpRsLocPort Integer32,
|
|
rcDnpRsRemPort Integer32,
|
|
rcDnpRsIpAdd IpAddress,
|
|
rcDnpRsLinkStats EnabledStatus
|
|
}
|
|
|
|
rcDnpRsPort OBJECT-TYPE
|
|
SYNTAX Integer32(1..65535)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The physical Serial Port Number for which this Entry contains DNP over
|
|
Raw Socket serial protocol configuration settings."
|
|
::= { rcDnpRsEntry 1 }
|
|
|
|
rcDnpRsCalllDir OBJECT-TYPE
|
|
SYNTAX RcCallDir
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Defines following:
|
|
- whether to accept an incoming connection 'in(0)' or
|
|
- to place an outgoing connection 'out(1)' or
|
|
- to place an outgoing connection and wait for incomming 'both(2)'
|
|
|
|
Note: This parameter is applicable only for TCP transport."
|
|
::= { rcDnpRsEntry 2 }
|
|
|
|
rcDnpRsTransport OBJECT-TYPE
|
|
SYNTAX RcTransport
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A transport protocol used for IP traffic for DNPRS on this port."
|
|
::= { rcDnpRsEntry 3 }
|
|
|
|
rcDnpRsMaxConns OBJECT-TYPE
|
|
SYNTAX Integer32(1..64)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The maximum number of allowed incoming TCP connections."
|
|
::= { rcDnpRsEntry 4 }
|
|
|
|
rcDnpRsLocPort OBJECT-TYPE
|
|
SYNTAX Integer32(1024..65535)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The local IP port to listen to an incoming TCP connection or UDP
|
|
datagrams."
|
|
::= { rcDnpRsEntry 5 }
|
|
|
|
rcDnpRsRemPort OBJECT-TYPE
|
|
SYNTAX Integer32(1024..65535)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The remote TCP port to use when placing an outgoing connection."
|
|
::= { rcDnpRsEntry 6 }
|
|
|
|
rcDnpRsIpAdd OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Defines the IpAddress based on the following:
|
|
- For outgoing TCP connection (client) 'rcRawSockCallDir' is 'out(2)'
|
|
this is the remote IP address to communicate with.
|
|
- For incoming TCP connection (server), 'rcRawSockCallDir' is
|
|
'out(2)' or 'both(3)' this is the local interface IP address to
|
|
listen to the local port for connection request.
|
|
- For both, outgoing and incoming connections enabled
|
|
(client or server), 'rcRawSockCallDir' is 'both(3)' this is the
|
|
remote IP address where to place an outgoing TCP connection request
|
|
or from which to accept calls.
|
|
- For UDP transport address of interface to listen to UDP datagrams."
|
|
::= { rcDnpRsEntry 7 }
|
|
|
|
rcDnpRsLinkStats OBJECT-TYPE
|
|
SYNTAX EnabledStatus
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Enables links statistics collection."
|
|
::= { rcDnpRsEntry 8 }
|
|
|
|
-- ---------------------------------------------------------------------- --
|
|
-- ---------------------------------------------------------------------- --
|
|
rcMirrBitsTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF RcMirrBitsEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This table presents the list of ports with configuration options for
|
|
configuring the Mirrirod Bits serial protocol on RuggedCom serial
|
|
devices"
|
|
::= { rcMirrorBits 1}
|
|
|
|
rcMirrBitsEntry OBJECT-TYPE
|
|
SYNTAX RcMirrBitsEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"List of configuration options for all the ports configured for
|
|
Mirrored Bits serial protocol."
|
|
INDEX { rcMirrBitsPort }
|
|
::= { rcMirrBitsTable 1 }
|
|
|
|
RcMirrBitsEntry::=
|
|
SEQUENCE {
|
|
rcMirrBitsPort Integer32,
|
|
rcMirrBitsTransport RcTransport,
|
|
rcMirrBitsLocPort Integer32,
|
|
rcMirrBitsRemPort Integer32,
|
|
rcMirrBitsIpAdd IpAddress,
|
|
rcMirrBitsLinkStats EnabledStatus
|
|
}
|
|
|
|
rcMirrBitsPort OBJECT-TYPE
|
|
SYNTAX Integer32(1..65535)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The physical Serial Port Number for which this Entry contains the
|
|
Mirrored Bits serial protocol configuration settings."
|
|
::= { rcMirrBitsEntry 1 }
|
|
|
|
rcMirrBitsTransport OBJECT-TYPE
|
|
SYNTAX RcTransport
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A transport protocol used for IP traffic for MorroredBits on this
|
|
port.
|
|
|
|
This object is always set to the value of 'udp(2)'."
|
|
::= { rcMirrBitsEntry 2 }
|
|
|
|
rcMirrBitsLocPort OBJECT-TYPE
|
|
SYNTAX Integer32(1024..65535)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The local IP port to listen to UDP datagrams."
|
|
::= { rcMirrBitsEntry 3 }
|
|
|
|
rcMirrBitsRemPort OBJECT-TYPE
|
|
SYNTAX Integer32(1024..65535)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The Remote port to which protocol on this port can exchange UDP
|
|
datagrams."
|
|
::= { rcMirrBitsEntry 4 }
|
|
|
|
rcMirrBitsIpAdd OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The IP Address of interface to listen to UDP datagrams."
|
|
::= { rcMirrBitsEntry 5 }
|
|
|
|
rcMirrBitsLinkStats OBJECT-TYPE
|
|
SYNTAX EnabledStatus
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Enables links statistics collection."
|
|
::= { rcMirrBitsEntry 6 }
|
|
|
|
-- ---------------------------------------------------------------------- --
|
|
-- ---------------------------------------------------------------------- --
|
|
rcTelnetComportTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF RcTelnetComportEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This table provides a list of port entries configured for TelnetPort
|
|
Comport serial protocolwith configuration options."
|
|
::= { rcTelnetComport 1 }
|
|
|
|
rcTelnetComportEntry OBJECT-TYPE
|
|
SYNTAX RcTelnetComportEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"List of ports with configuration options for TelnetPortComports serial
|
|
protocol."
|
|
INDEX { rcTelnetComportPort }
|
|
::= { rcTelnetComportTable 1 }
|
|
|
|
RcTelnetComportEntry ::=
|
|
SEQUENCE {
|
|
rcTelnetComportPort Integer32,
|
|
rcTelnetComportPackChar Integer32,
|
|
rcTelnetComportPackTimer Integer32,
|
|
rcTelnetComportPackSize Integer32,
|
|
rcTelnetComportFlowControl RcFlowControl,
|
|
rcTelnetComportCallDir RcCallDir,
|
|
rcTelnetComportLocPort Integer32,
|
|
rcTelnetComportRemPort Integer32,
|
|
rcTelnetComportIpAdd IpAddress,
|
|
rcTelnetComportLinkStats EnabledStatus
|
|
}
|
|
|
|
rcTelnetComportPort OBJECT-TYPE
|
|
SYNTAX Integer32(1..65535)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Thephysical Serial Port Number for which this Entry contains the
|
|
TelnetPortComport serial protocol configuration settings."
|
|
::= { rcTelnetComportEntry 1 }
|
|
|
|
rcTelnetComportPackChar OBJECT-TYPE
|
|
SYNTAX Integer32(0..255)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The character that can be used to force forwarding of accumulated
|
|
data to the network.
|
|
|
|
If a packetization character is not configured - object is set to the
|
|
value of '256', accumulated data will be forwarded based upon the
|
|
paketization timeout parameter which is the value set for object
|
|
rcTelnetComportPackTimer."
|
|
::= { rcTelnetComportEntry 2 }
|
|
|
|
rcTelnetComportPackTimer OBJECT-TYPE
|
|
SYNTAX Integer32(3..1000)
|
|
UNITS "milliseconds"
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The delay from the last received character until when data is
|
|
forwarded."
|
|
::= { rcTelnetComportEntry 3 }
|
|
|
|
rcTelnetComportPackSize OBJECT-TYPE
|
|
SYNTAX Integer32(64..1400)
|
|
UNITS "bytes"
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The maximum number of bytes received from serial port to be packed
|
|
in one IP packet."
|
|
::= { rcTelnetComportEntry 4 }
|
|
|
|
rcTelnetComportFlowControl OBJECT-TYPE
|
|
SYNTAX RcFlowControl
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The type of FlowControl to be used on the port."
|
|
::= { rcTelnetComportEntry 5 }
|
|
|
|
rcTelnetComportCallDir OBJECT-TYPE
|
|
SYNTAX RcCallDir
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Defines following:
|
|
- whether to accept an incoming connection 'in(0)' or
|
|
- to place an outgoing connection 'out(1)' or
|
|
- to place an outgoing connection and wait for incomming 'both(2)'.
|
|
|
|
This protocol support only TCP transport."
|
|
::= { rcTelnetComportEntry 6 }
|
|
|
|
rcTelnetComportLocPort OBJECT-TYPE
|
|
SYNTAX Integer32(1024..65535)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The local IP port to listen to an incoming TCP connection."
|
|
::= { rcTelnetComportEntry 7 }
|
|
|
|
rcTelnetComportRemPort OBJECT-TYPE
|
|
SYNTAX Integer32(1024..65535)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The remote TCP port to use when placing an outgoing connection."
|
|
::= { rcTelnetComportEntry 8 }
|
|
|
|
rcTelnetComportIpAdd OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Defines the IpAddress based on the following:
|
|
- For outgoing TCP connection (client) 'rcRawSockCallDir' is 'out(2)'
|
|
this is the remote IP address to communicate with.
|
|
- For incoming TCP connection (server), 'rcRawSockCallDir' is
|
|
'out(2)' or 'both(3)' this is the local interface IP address to
|
|
listen to the local port for connection request.
|
|
- For both, outgoing and incoming connections enabled
|
|
(client or server), 'rcRawSockCallDir' is 'both(3)' this is the
|
|
remote IP address where to place an outgoing TCP connection request
|
|
or from which to accept calls."
|
|
::= { rcTelnetComportEntry 9 }
|
|
|
|
rcTelnetComportLinkStats OBJECT-TYPE
|
|
SYNTAX EnabledStatus
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Enables links statistics collection."
|
|
::= { rcTelnetComportEntry 10 }
|
|
|
|
-- ---------------------------------------------------------------------- --
|
|
-- Connection Statistics table
|
|
-- ---------------------------------------------------------------------- --
|
|
|
|
rcConnStatsTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF RcConnStatsEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This table provides the statictics information for all active TCP
|
|
connections on the RuggedCom serial device."
|
|
::= { rcConnStats 1 }
|
|
|
|
rcConnStatsEntry OBJECT-TYPE
|
|
SYNTAX RcConnStatsEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"List of parameters providing the statictics information for all active TCP
|
|
connections on the RuggedCom serial device."
|
|
INDEX {
|
|
rcConnStatsRemIp,
|
|
rcConnStatsRemPort,
|
|
rcConnStatsLocPort
|
|
}
|
|
::= { rcConnStatsTable 1 }
|
|
|
|
RcConnStatsEntry ::= SEQUENCE {
|
|
rcConnStatsRemIp IpAddress,
|
|
rcConnStatsRemPort Integer32,
|
|
rcConnStatsLocPort Integer32,
|
|
rcConnStatsRxPkts Integer32,
|
|
rcConnStatsTxPkts Integer32
|
|
}
|
|
|
|
rcConnStatsRemIp OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The remote IP address of the TCP connection."
|
|
::= { rcConnStatsEntry 1 }
|
|
|
|
rcConnStatsRemPort OBJECT-TYPE
|
|
SYNTAX Integer32(1024..65535)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The remote port number of the connection."
|
|
::= { rcConnStatsEntry 2 }
|
|
|
|
rcConnStatsLocPort OBJECT-TYPE
|
|
SYNTAX Integer32(1024..65535)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The local port number of the connection."
|
|
::= { rcConnStatsEntry 3 }
|
|
|
|
rcConnStatsRxPkts OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of received packets."
|
|
::= { rcConnStatsEntry 4 }
|
|
|
|
rcConnStatsTxPkts OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of transmitted packets."
|
|
::= { rcConnStatsEntry 5 }
|
|
|
|
-- ---------------------------------------------------------------------- --
|
|
-- SerialDevice Commands
|
|
-- ---------------------------------------------------------------------- --
|
|
|
|
rcSerDeviceCmndResetPort OBJECT-TYPE
|
|
SYNTAX PortList
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The list of ports for which Reset should be performed on the
|
|
RuggedCom Serial devices.
|
|
|
|
A read attempt for this object always returns an empty list of ports."
|
|
::= { rcSerDeviceCmnd 1}
|
|
|
|
rcSerDeviceCmndClearStats OBJECT-TYPE
|
|
SYNTAX PortList
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The list of ports for which Clearing statistics command should be
|
|
performed on the RuggedCom Serial devices.
|
|
|
|
A read attempt for this object always returns an empty list of ports."
|
|
::= { rcSerDeviceCmnd 2}
|
|
|
|
-- ---------------------------------------------------------------------- --
|
|
--
|
|
-- ---------------------------------------------------------------------- --
|
|
rcSerialPortParamsGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
rcSerialPortIfIndex,
|
|
rcSerialProtocol,
|
|
rcSerialPortType,
|
|
rcSerialForceHD,
|
|
rcSerialTurnAround,
|
|
rcSerialPostTxDelay,
|
|
rcSerialHoldTime,
|
|
rcSerialDscp,
|
|
rcSerialRxtoTxDelay
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Objects related to global settings for RuggedCom serial devices."
|
|
::= { rcSerialGroups 1 }
|
|
|
|
rcSerialMbServerGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
rcMbServerRespTimer,
|
|
rcMbServerAuxTcpPort,
|
|
rcMbServerSendExcep,
|
|
rcMbServerLinkStats
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Objects related to settings ModBus Server protocol for RuggedCom serial
|
|
devices."
|
|
::= { rcSerialGroups 2 }
|
|
|
|
rcSerialMbClientGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
rcMbClientIPPort,
|
|
rcMbClientFwdExcp,
|
|
rcMbClientLinkStats,
|
|
rcMbClientDscp
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Objects related to settings ModBus client protocol for RuggedCom serial
|
|
devices."
|
|
::= { rcSerialGroups 3 }
|
|
|
|
rcSerialRawSocketGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
rcRawSockPackChar,
|
|
rcRawSockPackTimer,
|
|
rcRawSockPackSize,
|
|
rcRawSockFlowControl,
|
|
rcRawSockTransport,
|
|
rcRawSockCallDir,
|
|
rcRawSockMaxConn,
|
|
rcRawSockLocPort,
|
|
rcRawSockRemPort,
|
|
rcRawSockIpAdd,
|
|
rcRawSockLinkStats
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Objects related to settings for raw Socket protocol on RuggedCom serial
|
|
devices."
|
|
::= { rcSerialGroups 4 }
|
|
|
|
rcSerialPreEmpRawSockGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
rcPreemptRSPackChar,
|
|
rcPreemptRSPackTimer,
|
|
rcPreemptRSPackSize,
|
|
rcPreemptRSFlowControl,
|
|
rcPreemptRSLocPort,
|
|
rcPreemptRSRemPort,
|
|
rcPreemptRSIpAdd,
|
|
rcPreemptRSLinkStats,
|
|
rcPreemptRSDynPackChar,
|
|
rcPreemptRSDynPackTimer,
|
|
rcPreemptRSDynTimeout
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Objects related to settings for Preemptive Raw Socket serial protocol
|
|
on RuggedCom serial devices."
|
|
::= { rcSerialGroups 5 }
|
|
|
|
rcSerialTinAndWinGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
rcTinAndWinTinMode,
|
|
rcTinAndWinTinTrans,
|
|
rcTinAndWinWinTrans,
|
|
rcTinAndWinTinIpPort,
|
|
rcTinAndWinWinIpPort,
|
|
rcTinAndWinMsgAgingTime,
|
|
rcTinAndWinAddrAgingTime,
|
|
rcTinAndWinBroadCastAddr,
|
|
rcTinAndWinUniAddr,
|
|
rcTinAndWinLinkStats,
|
|
rcTinAndWinWinDscp,
|
|
rcTinAndWinTinDscp
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Objects related to settings for Tin and Win protocols on RuggedCom
|
|
serial devices."
|
|
::= { rcSerialGroups 6 }
|
|
|
|
rcSerialMicrolokGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
rcMicrolokTransport,
|
|
rcMicrolokIpPort,
|
|
rcMicrolokLinkStats,
|
|
rcMicrolokDscp
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Objects related to settings for Microlok protocols on RuggedCom
|
|
serial devices."
|
|
::= { rcSerialGroups 7 }
|
|
|
|
rcSerialDnpGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
rcDnpTransport,
|
|
rcDnpIpPort,
|
|
rcDnpLearning,
|
|
rcDnpAgingTimer,
|
|
rcDnpLinkStats,
|
|
rcDnpDscp
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Objects related to settings for Dnp protocols on RuggedCom
|
|
serial devices."
|
|
::= { rcSerialGroups 8 }
|
|
|
|
rcSerialDnpRsGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
rcDnpRsCalllDir,
|
|
rcDnpRsTransport,
|
|
rcDnpRsMaxConns,
|
|
rcDnpRsLocPort,
|
|
rcDnpRsRemPort,
|
|
rcDnpRsIpAdd,
|
|
rcDnpRsLinkStats
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Objects related to settings for Dnp over Raw Socket protocol on
|
|
RuggedCom serial devices."
|
|
::= { rcSerialGroups 9 }
|
|
|
|
rcSerialMirrBitsGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
rcMirrBitsTransport,
|
|
rcMirrBitsLocPort,
|
|
rcMirrBitsRemPort,
|
|
rcMirrBitsIpAdd,
|
|
rcMirrBitsLinkStats
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Objects related to settings for Mirrored Bits protocol on
|
|
RuggedCom serial devices."
|
|
::= { rcSerialGroups 10 }
|
|
|
|
rcSerialTelnetComportGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
rcTelnetComportPackChar,
|
|
rcTelnetComportPackTimer,
|
|
rcTelnetComportPackSize,
|
|
rcTelnetComportFlowControl,
|
|
rcTelnetComportCallDir,
|
|
rcTelnetComportLocPort,
|
|
rcTelnetComportRemPort,
|
|
rcTelnetComportIpAdd,
|
|
rcTelnetComportLinkStats
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Objects related to settings for TelnetPortComport protocol on
|
|
RuggedCom serial devices."
|
|
::= { rcSerialGroups 11 }
|
|
|
|
rcSerialConnStatsGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
rcConnStatsRxPkts,
|
|
rcConnStatsTxPkts
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Objects related to Connection Statistics from Serial protocol on RuggedCom
|
|
serial devices."
|
|
::= { rcSerialGroups 15 }
|
|
|
|
rcSerialCommandsGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
rcSerDeviceCmndResetPort,
|
|
rcSerDeviceCmndClearStats
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Objects related to Serial Port Commands on RuggedCom serial devices."
|
|
::= { rcSerialGroups 16 }
|
|
|
|
END
|