RC-IEC-62439-3-MIB-AC DEFINITIONS ::= BEGIN
IMPORTS
MODULE-IDENTITY FROM SNMPv2-SMI
AGENT-CAPABILITIES FROM SNMPv2-CONF
ruggedcomAgentCapability FROM RUGGEDCOM-MIB;
ruggedcomIEC624393ACModule MODULE-IDENTITY
LAST-UPDATED "201310041700Z" -- Oct 4, 17:00 EST 2013;
ORGANIZATION "RuggedCom - Industrial Strength Networks"
CONTACT-INFO
"Postal: RuggedCom Inc.
300 Applewood Crescent
Concord, Ontario,
L4K 5C7 Canada
Tel: 1-905-856-5288
E-Mail: support@ruggedcom.com"
DESCRIPTION
"The capabilities description for IEC-62439-3-MIB."
REVISION "201310041700Z" -- Oct 4, 17:00 EST 2013;
DESCRIPTION
"Initial version of this MIB module."
::= { ruggedcomAgentCapability 40 }
-- ---------------------------------------------------------------------- --
-- RSTP MIB Agent Capabilities
-- ---------------------------------------------------------------------- --
ruggedcomIEC624393AC AGENT-CAPABILITIES
PRODUCT-RELEASE "ROS-MB"
STATUS current
DESCRIPTION
"IEC-62439-3-MIB Agent Capabilities."
SUPPORTS IEC-62439-3-MIB
INCLUDES { lreConfigurationGeneralGroup,
lreConfigurationInterfaceGroup,
lreStatisticsInterfaceGroup }
VARIATION lreRowStatus
ACCESS read-only
DESCRIPTION
"One and only one row (LRE) is supported."
VARIATION lreMacAddress
ACCESS read-only
DESCRIPTION
"This configuration setting is read-only."
VARIATION lreDuplicateDiscard
ACCESS read-only
DESCRIPTION
"This configuration setting is read-only. Value:
discard(2)."
VARIATION lreTransparentReception
ACCESS read-only
DESCRIPTION
"This configuration setting is read-only. Value:
passRCT(2)."
VARIATION lreHsrLREMode
ACCESS read-only
DESCRIPTION
"When the switch is in HSR mode, this configuration
setting is accessible but is read-only. Value:
modeh(1). When the switch is in PRP mode, this
setting is not accessible because it does not apply."
VARIATION lreSwitchingEndNode
ACCESS read-only
DESCRIPTION
"This configuration setting is read-only."
VARIATION lreRedBoxIdentity
ACCESS not-implemented
DESCRIPTION
"This setting is not applicable because the switch
does not do HSR/PRP coupling."
VARIATION lreEvaluateSupervision
ACCESS read-only
DESCRIPTION
"This configuration setting is read-only."
VARIATION lreProxyNodeTableClear
ACCESS not-implemented
DESCRIPTION
"This action is not supported."
VARIATION lreCntTxC
DESCRIPTION
"Only frames sent out the local port are counted."
VARIATION lreCntErrWrongLanC
ACCESS not-implemented
DESCRIPTION
"This statistic is not applicable because the switch
does not do HSR/PRP coupling."
VARIATION lreCntRxC
DESCRIPTION
"Only frames received on the local port are counted."
VARIATION lreCntUniqueA
ACCESS not-implemented
DESCRIPTION
"This statistic is not supported."
VARIATION lreCntUniqueB
ACCESS not-implemented
DESCRIPTION
"This statistic is not supported."
VARIATION lreCntUniqueC
ACCESS not-implemented
DESCRIPTION
"This statistic is not supported."
VARIATION lreCntMultiA
ACCESS not-implemented
DESCRIPTION
"This statistic is not supported."
VARIATION lreCntMultiB
ACCESS not-implemented
DESCRIPTION
"This statistic is not supported."
VARIATION lreCntMultiC
ACCESS not-implemented
DESCRIPTION
"This statistic is not supported."
VARIATION lreTimeLastSeenA
ACCESS not-implemented
DESCRIPTION
"This statistic is not supported."
VARIATION lreTimeLastSeenB
ACCESS not-implemented
DESCRIPTION
"This statistic is not supported."
-- ---------------------------------------------------------------------- --
::= { ruggedcomIEC624393ACModule 1 }
END