-- * Module Name: HMS024R13.MIB
|
|
-- *
|
|
-- * SCTE Status: ADOPTED FEBRUARY 15, 2002
|
|
-- *
|
|
-- * Description: Implements SCTE-HMS-COMMON-MIB definitions
|
|
-- *
|
|
-- * This MIB contains common information about NEs.
|
|
-- * MIB items cover administrative information
|
|
-- * such as name, ID, model number, serial numbers vendor, and location;
|
|
-- * health indicators such as status and service state; and functional
|
|
-- * information such as power level and frequency range.
|
|
-- *
|
|
-- * CAUTION: A SET OF ANY OBJECT STORED IN NON-VOLATILE MEMORY MAY RESULT IN AN ACTUAL WRITE TO NON-VOLATILE MEMORY,
|
|
-- * WHICH TYPICALLY HAS A FINITE LIFETIME. EXCESSIVE WRITING TO THESE OBJECTS COULD SHORTEN THE USEFUL LIFE OF THE
|
|
-- * DEVICE.
|
|
-- *
|
|
-- * Objects which are not present must not have the properties present either.
|
|
-- *
|
|
-- *
|
|
-- ****************************************************************************
|
|
|
|
SCTE-HMS-COMMON-MIB DEFINITIONS ::= BEGIN
|
|
IMPORTS
|
|
OBJECT-TYPE FROM RFC-1212
|
|
TRAP-TYPE FROM RFC-1215
|
|
Counter FROM RFC1155-SMI
|
|
NetworkAddress FROM RFC1155-SMI
|
|
DisplayString FROM RFC1213-MIB
|
|
scteHmsTree FROM SCTE-ROOT
|
|
-- *
|
|
-- * Common MIB prefix
|
|
-- *
|
|
commonIdent FROM SCTE-HMS-ROOTS
|
|
;
|
|
|
|
-- *
|
|
-- * Groups in the Common MIB
|
|
-- *
|
|
commonAdminGroup OBJECT IDENTIFIER ::= { commonIdent 1 }
|
|
commonMACGroup OBJECT IDENTIFIER ::= { commonIdent 2 }
|
|
commonMulticastGroup OBJECT IDENTIFIER ::= { commonIdent 3 }
|
|
commonStatsGroup OBJECT IDENTIFIER ::= { commonIdent 4 }
|
|
commonRfGroup OBJECT IDENTIFIER ::= { commonIdent 5 }
|
|
|
|
commonMacStats OBJECT IDENTIFIER ::= { commonStatsGroup 1 }
|
|
|
|
|
|
-- *
|
|
-- *
|
|
-- * The Transponder Administrative Group
|
|
-- *
|
|
-- * Implementation of the Transponder Administrative Group is mandatory.
|
|
-- * Within the group a number of objects are optional.
|
|
-- *
|
|
|
|
commonLogicalID OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(0..40))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Specifies the logical ID for the network element used by network
|
|
management systems. The ID will often remain with a specific location
|
|
regardless of any specific network element's characteristics.
|
|
The value for this object is maintained in non-volatile memory."
|
|
::= { commonAdminGroup 1 }
|
|
|
|
commonVendor OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..255))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Displays the manufacturer of the network element.
|
|
Displayed in human-readable format."
|
|
::= { commonAdminGroup 2 }
|
|
|
|
commonModelNumber OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..255))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Displays the model number of the network element.
|
|
Displayed in human-readable format."
|
|
::= { commonAdminGroup 3 }
|
|
|
|
commonSerialNumber OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..255))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Returns the Serial Number of the Network Element.
|
|
Displayed in human-readable format."
|
|
::= { commonAdminGroup 4 }
|
|
|
|
commonVendorInfo OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..255))
|
|
ACCESS read-only
|
|
STATUS optional
|
|
DESCRIPTION
|
|
"Returns vendor-specific information.
|
|
Displayed in human-readable format."
|
|
::= { commonAdminGroup 5 }
|
|
|
|
commonNEStatus OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(1))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Bit mask, identical to that used in the Status field of
|
|
the STATRESP PDU. See SCTE 25-2 (formerly HMS004).
|
|
|
|
Bit 0: CHNLRQST
|
|
Bit 1: CNTNRM
|
|
Bit 2: CNTCUR
|
|
Bit 3: MAJOR ALARMS
|
|
Bit 4: MINOR ALARMS
|
|
Bit 5: RSVD1
|
|
Bit 6: RSVD2
|
|
Bit 7: RSVD3"
|
|
::= { commonAdminGroup 6 }
|
|
|
|
commonReset OBJECT-TYPE
|
|
SYNTAX INTEGER { reset (1) }
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This object is used to reset the NE by writing 1 to it.
|
|
Other values written to the object have no effect.
|
|
Reading the object returns a 1, and has no effect on the unit."
|
|
::= { commonAdminGroup 7 }
|
|
|
|
commonAlarmDetectionControl OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
detectionDisabled (1),
|
|
detectionEnabled (2),
|
|
detectionEnabledAndRegenerate (3)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This object is used to control the detection of alarms in this NE.
|
|
|
|
When a threshold from either the property table or the discrete
|
|
property table is crossed in a manner described by that MIB, then
|
|
an alarm is said to have occurred. When the alarm is detected, an
|
|
entry is placed in the alarm log table, which serves as a log of the
|
|
most recent alarm events. When an alarm is detected, then an alarm
|
|
trap is also generated. A property which is not in the nominal
|
|
state will have an entry in the currentAlarmTable.
|
|
|
|
The detectionDisabled(1) value prevents the threshold detection
|
|
process associated with the property table and discrete property
|
|
table from running. The NE will not generate alarms. The contents
|
|
of the alarmLogTable, currentAlarmTable, each instance of
|
|
discreteAlarmState, and each instance of currentAlarmState
|
|
remain in the state prior to detectionDisabled being applied.
|
|
|
|
The detectionEnabled(2) value permits alarm detection to run.
|
|
The detection process continues from the state the transponder
|
|
was in prior to detectionEnabled being set.
|
|
|
|
The detectionEnabledAndRegenerate(3) value clears all alarm
|
|
information and permits alarm detection to run. All alarm
|
|
properties, both discrete and analog, are restored to the
|
|
nominal value before alarm detection runs. Any properties
|
|
that are in an alarm state SHALL NOT produce a 'return to normal'
|
|
alarm as part of the process. Setting this value clears the
|
|
alarmLogTable and the currentAlarmTable.
|
|
|
|
The detectionEnabledAndRegenerate(3) value is transient.
|
|
When setting commonAlarmDetectionControl to
|
|
detectionEnabledAndRegnerate(3), the response will contain
|
|
detectionEnabledAndRegnerate(3). Subsequent reads of the
|
|
object report detectionEnabled(2).
|
|
|
|
The detectionDisabled(1) value does not affect the generation
|
|
of hmsColdStart or hmsWarmStart traps. Traps added in
|
|
the future are assumed to be unaffected by this object,
|
|
unless stated in the description of that trap.
|
|
|
|
This object has a default value of detectionEnabled(2).
|
|
|
|
The value for this object is maintained in non-volatile memory."
|
|
|
|
::= { commonAdminGroup 8 }
|
|
|
|
commonNetworkAddress OBJECT-TYPE
|
|
SYNTAX NetworkAddress
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This variable reports the network address (e.g., IP address) of
|
|
the NE. This object was added to support the generation of traps.
|
|
The value is retained in non-volatile memory. The value may be
|
|
set during the registration process by a MAC level command or
|
|
via a vendor's craft interface."
|
|
::= { commonAdminGroup 9 }
|
|
|
|
commonCheckCode OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This object reports the Check Code for the transponder's
|
|
configuration. The check code is generated from objects
|
|
which are stored in non-volatile memory as well as those
|
|
objects which reports the transponder's physical configuration,
|
|
including monitored devices.
|
|
|
|
The algorithm used to generate the Check Code is vendor
|
|
specific.
|
|
|
|
Upon a restart of the transponder, the current value of the
|
|
check code is compared against the value previous to the
|
|
restart to determine if a hmsColdStart or a hmsWarmStart trap
|
|
is to be generated. This requires that the value of the
|
|
object be maintained in non-volatile memory for the comparison
|
|
operation after a restart.
|
|
|
|
When a value is written to this object, the check code is recalculated,
|
|
and the new value is returned in the GetResponse returned for the SetRequest.
|
|
Since this optimization is NOT SNMP compliant, the transponder MAY respond
|
|
in the SNMP compliant manner. Since this object description may impact an
|
|
SNMP manager, it is recommended that the value be subsequently retrieved
|
|
with a GetRequest, to guarantee that the desired value has been obtained.
|
|
|
|
In this case (on-demand recalculation), the hmsColdStart or hmsWarmStart traps
|
|
are NOT generated.
|
|
|
|
The value for this object is maintained in non-volatile memory."
|
|
::= { commonAdminGroup 10 }
|
|
|
|
commonTrapCommunityString OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(0..64))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This object defines the community string reported in a trap.
|
|
The default value is 'public'.
|
|
Use of this object does not preclude the use of enterprise
|
|
specific mechanisms to define community string values.
|
|
The value for this object is maintained in non-volatile memory."
|
|
::= { commonAdminGroup 11 }
|
|
|
|
commonTamperStatus OBJECT-TYPE
|
|
SYNTAX INTEGER { intact (1), compromised (2) }
|
|
ACCESS read-only
|
|
STATUS optional
|
|
DESCRIPTION
|
|
"Returns the status of the anti-tamper device of the network element.
|
|
this object requires an entry in the Discrete Property Table.
|
|
the intact(1) value represents ok, and the compromised(2) value
|
|
indicates an alarm."
|
|
::= { commonAdminGroup 12 }
|
|
|
|
commonInternalTemperature OBJECT-TYPE
|
|
SYNTAX INTEGER (-60..130)
|
|
ACCESS read-only
|
|
STATUS optional
|
|
DESCRIPTION
|
|
"Measured temperature inside the NE's case/housing.
|
|
Units degrees Celsius.
|
|
This item requires an entry in the properties MIB"
|
|
::= { commonAdminGroup 13 }
|
|
|
|
commonTime OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS optional
|
|
DESCRIPTION
|
|
"All values are unsigned 32 bit integers.
|
|
Time since the Epoch (00:00:00 UTC, January 1, 1970),
|
|
measured in seconds(POSIX)."
|
|
::= { commonAdminGroup 14 }
|
|
|
|
commonVarBindings OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This object indicates the maximum number of entries in the
|
|
variable-binding list which can be accepted by the unit.
|
|
A value of 0 indicates no specified limit."
|
|
::= { commonAdminGroup 15 }
|
|
|
|
commonResetCause OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
other (1),
|
|
powerup (2),
|
|
command (3),
|
|
watchdog (4),
|
|
craft (5)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This object reports the cause of the last reset."
|
|
::= { commonAdminGroup 16 }
|
|
|
|
commonCraftStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disconnected (1),
|
|
connected (2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This object reports the state of the craft interface.
|
|
The status of this object does not imply any change to
|
|
the transponder functionality through the MAC interface.
|
|
Not all transponders support a craft interface.
|
|
If the interface is not supported, the objects reports
|
|
disconnected(2).
|
|
|
|
This object requires an entry in the Discrete Property Table."
|
|
::= { commonAdminGroup 17 }
|
|
|
|
-- *
|
|
-- *
|
|
-- * The MAC Layer Group
|
|
-- *
|
|
-- * Implementation of the MAC Layer Group is mandatory.
|
|
-- * The objects are required to support the protocol defined
|
|
-- * by the Media Access Layer specification.
|
|
-- *
|
|
|
|
commonBackoffPeriod OBJECT-TYPE
|
|
SYNTAX INTEGER (0..16383)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The backoff period in millseconds. This parameter is used as
|
|
part of the random backoff period as defined by the Media Access
|
|
Control Layer specification SCTE 25-2(formerly HMS004).
|
|
|
|
Initial Power up default: 6 millseconds.
|
|
|
|
The value for this object is maintained in non-volatile memory."
|
|
::= { commonMACGroup 1 }
|
|
|
|
commonACKTimeoutWindow OBJECT-TYPE
|
|
SYNTAX INTEGER (0..255)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The Acknowledgement timeout window in milliseconds.
|
|
|
|
Initial Power up default: 19 milliseconds.
|
|
|
|
The value for this object is maintained in non-volatile memory."
|
|
::= { commonMACGroup 2 }
|
|
|
|
commonMaximumMACLayerRetries OBJECT-TYPE
|
|
SYNTAX INTEGER (0..255)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The maximum number of retries a NE can make for a specific packet.
|
|
This limit is intended to protect the network from a unit with
|
|
a faulty receiver.
|
|
|
|
Initial Power up default: 16.
|
|
|
|
The value for this object is maintained in non-volatile memory."
|
|
::= { commonMACGroup 3 }
|
|
|
|
commonMaxPayloadSize OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This object reports the maximum length of the payload supported
|
|
for a packet on the reverse or forward channel."
|
|
::= { commonMACGroup 4 }
|
|
|
|
commonBackoffMinimumExponent OBJECT-TYPE
|
|
SYNTAX INTEGER (0..15)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This object is used to define the minimum value of the exponent
|
|
used for the Backoff Algorithm as defined by the Media Access
|
|
Control Layer specification SCTE 25-2(formerly HMS004).
|
|
|
|
The default value is 6.
|
|
|
|
The value must be less than or equal to commonBackoffMaximumValue.
|
|
The value for this object is maintained in non-volatile memory."
|
|
::= { commonMACGroup 5 }
|
|
|
|
commonBackoffMaximumExponent OBJECT-TYPE
|
|
SYNTAX INTEGER (0..15)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This object is used to define the maximum value of the exponent
|
|
used for the Backoff Algorithm as defined by the Media Access
|
|
Control Layer specification SCTE 25-2(formerly HMS004).
|
|
|
|
The default value is 15.
|
|
|
|
The value must be greater than or equal to commonBackoffMinimumValue.
|
|
The value for this object is maintained in non-volatile memory."
|
|
::= { commonMACGroup 6 }
|
|
|
|
commonPhysAddress OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This variable reports the media dependant 'physical' address of
|
|
the NE. This object was added to support the generation of traps."
|
|
::= { commonMACGroup 7 }
|
|
|
|
|
|
-- *
|
|
-- *
|
|
-- * The Multicast Address Group
|
|
-- *
|
|
-- * Implementation of the Multicast Address Group is mandatory.
|
|
-- *
|
|
|
|
commonMaxMulticastAddresses OBJECT-TYPE
|
|
SYNTAX INTEGER (4..255)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Maximum number of multicast data link layer addresses
|
|
supported by this NE."
|
|
::= { commonMulticastGroup 1 }
|
|
|
|
commonMulticastAddressTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF CommonMulticastAddressEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The table containing the multicast addresses.
|
|
|
|
The value for all objects in this table are maintained
|
|
in non-volatile memory."
|
|
::= { commonMulticastGroup 2 }
|
|
|
|
commonMulticastAddressEntry OBJECT-TYPE
|
|
SYNTAX CommonMulticastAddressEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A list of information for multicast addresses."
|
|
INDEX { commonMulticastAddressIndex }
|
|
::= { commonMulticastAddressTable 1 }
|
|
|
|
CommonMulticastAddressEntry ::=
|
|
SEQUENCE
|
|
{
|
|
commonMulticastAddressIndex
|
|
INTEGER,
|
|
commonMulticastAddressNumber
|
|
OCTET STRING
|
|
}
|
|
|
|
commonMulticastAddressIndex OBJECT-TYPE
|
|
SYNTAX INTEGER (1..255)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Index into commonMulticastAddressTable."
|
|
::= { commonMulticastAddressEntry 1 }
|
|
|
|
commonMulticastAddressNumber OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(6))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The multicast address. Only entries with the I/G bit set are
|
|
accepted values. An empty entry is designated by setting
|
|
the object to the broadcast address."
|
|
::= { commonMulticastAddressEntry 2 }
|
|
|
|
|
|
-- *
|
|
-- *
|
|
-- * The MAC Statistics Group
|
|
-- *
|
|
-- * Implementation of the MAC Statistics Group is optional.
|
|
-- *
|
|
|
|
commonForwardPathLOSEvents OBJECT-TYPE
|
|
SYNTAX Counter
|
|
ACCESS read-write
|
|
STATUS optional
|
|
DESCRIPTION
|
|
"Count of forward path loss of signal (LOS) events. Can be reset to 0."
|
|
::= { commonMacStats 1 }
|
|
|
|
commonForwardPathFramingErrors OBJECT-TYPE
|
|
SYNTAX Counter
|
|
ACCESS read-write
|
|
STATUS optional
|
|
DESCRIPTION
|
|
"Count of framing errors on the forward path. Can be reset to 0."
|
|
::= { commonMacStats 2 }
|
|
|
|
commonForwardPathCRCErrors OBJECT-TYPE
|
|
SYNTAX Counter
|
|
ACCESS read-write
|
|
STATUS optional
|
|
DESCRIPTION
|
|
"Count of CRC errors on the forward path. Can be reset to 0."
|
|
::= { commonMacStats 3 }
|
|
|
|
commonInvalidMacCmds OBJECT-TYPE
|
|
SYNTAX Counter
|
|
ACCESS read-write
|
|
STATUS optional
|
|
DESCRIPTION
|
|
"Count of invalid MAC commands. Can be reset to 0."
|
|
::= { commonMacStats 4 }
|
|
|
|
|
|
-- *
|
|
-- *
|
|
-- * The RF Interface Group
|
|
-- *
|
|
-- * Implementation of the RF Interface Group is mandatory for
|
|
-- * those transponders which use RF Modems for the physical layer.
|
|
-- *
|
|
-- * Within the group a number of objects are optional. These
|
|
-- * optional objects are used to support auto-negotiation of
|
|
-- * power levels, forward channel frequency, and reverse channel
|
|
-- * frequency. The algorithms associated with these objects
|
|
-- * are vendor specific.
|
|
-- *
|
|
|
|
commonReturnPathFrequency OBJECT-TYPE
|
|
SYNTAX INTEGER (0..1000000000)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Return path frequency. Units 1 Hz.
|
|
The value for this object is maintained in non-volatile memory."
|
|
::= { commonRfGroup 1 }
|
|
|
|
commonForwardPathFrequency OBJECT-TYPE
|
|
SYNTAX INTEGER (0..1000000000)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Forward path frequency. Units 1 Hz.
|
|
The value for this object is maintained in non-volatile memory."
|
|
::= { commonRfGroup 2 }
|
|
|
|
commonProvisionedReturnPowerLevel OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Return path power level to be used. Units 0.1 dBmV.
|
|
The value used internally will be rounded to the nearest supported
|
|
value. The object reports the requested value, not the rounded value.
|
|
The value for this object is maintained in non-volatile memory."
|
|
::= { commonRfGroup 3 }
|
|
|
|
commonForwardPathReceiveLevel OBJECT-TYPE
|
|
SYNTAX INTEGER (-1000..1000)
|
|
ACCESS read-only
|
|
STATUS optional
|
|
DESCRIPTION
|
|
"Returns the received forward path power level. Units 0.1 dBmV."
|
|
::= { commonRfGroup 4 }
|
|
|
|
commonMaxReturnPower OBJECT-TYPE
|
|
SYNTAX INTEGER (200..600)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The maximum return path power to be used by the NE. Units 0.1 dBmV.
|
|
The value for this object is maintained in non-volatile memory."
|
|
::= { commonRfGroup 5 }
|
|
|
|
|
|
-- *
|
|
-- *
|
|
-- * The following definitions use the TRAP-TYPE macro as
|
|
-- * defined in RFC1215.
|
|
-- *
|
|
-- * The community string is defined by commonTrapCommunityString.
|
|
-- *
|
|
-- * The hmsColdStart and hmsWarmStart traps are used rather than
|
|
-- * the standard SNMP coldStart and warmStart, to permit the
|
|
-- * physical address of the transponder to be reported in the trap.
|
|
-- *
|
|
-- *
|
|
|
|
hmsColdStart TRAP-TYPE
|
|
ENTERPRISE scteHmsTree
|
|
VARIABLES { commonPhysAddress, commonLogicalID}
|
|
DESCRIPTION
|
|
"A hmsColdStart trap signifies that the sending protocol
|
|
entity is reinitializing itself such that the agent's
|
|
configuration or the protocol entity implementation may
|
|
be altered.
|
|
|
|
This trap is only issued by the transponder once the
|
|
registration has been completed successfully."
|
|
::= 0
|
|
|
|
hmsWarmStart TRAP-TYPE
|
|
ENTERPRISE scteHmsTree
|
|
VARIABLES { commonPhysAddress, commonLogicalID }
|
|
DESCRIPTION
|
|
"A hmsWarmStart trap signifies that the sending protocol
|
|
entity is reinitializing itself such that neither the agent's
|
|
configuration nor the protocol entity implementation is
|
|
altered.
|
|
|
|
This trap is only issued by the transponder once the
|
|
registration has been completed successfully."
|
|
::= 2
|
|
|
|
END
|