-- MY-INTERFACE-MIB.mib: My interface MIB file
--
-- $Copyright$
--
-- *****************************************************************
--
MY-INTERFACE-MIB DEFINITIONS ::= BEGIN
IMPORTS
MODULE-IDENTITY,
OBJECT-TYPE,
NOTIFICATION-TYPE,
Integer32,
Counter32,
IpAddress
FROM SNMPv2-SMI
VlanId
FROM Q-BRIDGE-MIB
TruthValue,
DisplayString,
RowStatus,
MacAddress
FROM SNMPv2-TC
MODULE-COMPLIANCE,
OBJECT-GROUP,
NOTIFICATION-GROUP
FROM SNMPv2-CONF
ConfigStatus,
MemberMap,
IfIndex
FROM MY-TC
EnabledStatus
FROM P-BRIDGE-MIB
myMgmt
FROM MY-SMI;
myInterfaceMIB MODULE-IDENTITY
LAST-UPDATED "200203200000Z"
ORGANIZATION "$Company$"
CONTACT-INFO
"
Tel: $Telephone$
E-mail: $E-mail$"
DESCRIPTION
"This module defines my interface mibs."
REVISION "200203200000Z"
DESCRIPTION
"Initial version of this MIB module."
::= { myMgmt 10}
myIfConfigMIBObjects OBJECT IDENTIFIER ::= { myInterfaceMIB 1 }
myIfTable OBJECT-TYPE
SYNTAX SEQUENCE OF MyIfEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"list of interface basic configuration objects."
::= { myIfConfigMIBObjects 1 }
myIfEntry OBJECT-TYPE
SYNTAX MyIfEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Entry contains interface basic configurations."
INDEX { myIfIndex }
::= { myIfTable 1 }
MyIfEntry ::=
SEQUENCE {
myIfIndex IfIndex,
myIfPortType INTEGER,
myIfFlowControlAdminStatus INTEGER,
myIfFlowControlOperStatus EnabledStatus,
myIfAdminSpeed INTEGER,
myIfAdminDuplex INTEGER,
myIfOperSpeed INTEGER,
myIfOperDuplex INTEGER,
myIfManageStatus EnabledStatus,
myIfIpBroadcast IpAddress,
myIfLayer INTEGER,
myIfMode INTEGER,
myIfCounterClear Integer32,
myIfEntryStatus ConfigStatus,
myIfMediumType INTEGER
}
myIfIndex OBJECT-TYPE
SYNTAX IfIndex
MAX-ACCESS read-only
STATUS current
DESCRIPTION
" "
::= { myIfEntry 1 }
myIfPortType OBJECT-TYPE
SYNTAX INTEGER {
unknown(1),
port10M100MBASETX(2),
port100MBASEFXL(3),
port100MBASEFXS(4),
port1000MBASESX(5),
port1000MBASELX(6),
port1000MBASETX(7),
portGBIC(8),
port100MBASEFX(9),
port1000MBASEFX(10),
portSFP(11),
port10GBASESR(12),
port10GBASELR(13),
port10GBASEER(14),
port10GBASELX4(15),
port10GBASESW(16),
port10GBASELW(17),
port10GBASEEW(18),
port10GBASE(19)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Port type of this port, list as above.
port100MBASEFX indicates that port is port100MBASEFXL or port100MBASEFXS,
and system doesn't distinguish.
port1000MBASEFX indicates that port is port1000MBASEFLX or port1000MBASEFSX,
and system doesn't distinguish.
This attribute apply physical port"
::= { myIfEntry 2 }
myIfFlowControlAdminStatus OBJECT-TYPE
SYNTAX INTEGER {
enabled(1),
disabled(2),
autonego(3),
unknown(4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Flow control of a port management status.
This attribute apply physical port and aggreate port"
::= { myIfEntry 3 }
myIfFlowControlOperStatus OBJECT-TYPE
SYNTAX EnabledStatus
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Oper status: after the negotiation between two ports connetted
the flow contrl status.
This attribute apply physical port and aggreate port"
::= { myIfEntry 4 }
myIfAdminSpeed OBJECT-TYPE
SYNTAX INTEGER {
speed10Mb(1),
speed100Mb(2),
speed1000Mb(3),
autonego(4),
speed10Gb(5),
unknown(6)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"port speed settings.
This attribute apply physical port and aggreate port"
::= { myIfEntry 5 }
myIfAdminDuplex OBJECT-TYPE
SYNTAX INTEGER {
full(1),
half(2),
autonego(3),
unknown(4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"port duplex settings.
This attribute apply physical port and aggreate port"
::= { myIfEntry 6 }
myIfOperSpeed OBJECT-TYPE
SYNTAX INTEGER {
speed10Mb(1),
speed100Mb(2),
speed1000Mb(3),
unknown(4),
speed10Gb(5)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"After two port have negotiated the speed status,and this object
is the working speed status. while the port link status is down ,
then the speed status is unknown(4).
This attribute apply physical port and aggreate port"
::= { myIfEntry 7 }
myIfOperDuplex OBJECT-TYPE
SYNTAX INTEGER {
full(1),
half(2),
unknown(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"After two port have negotiated the duplex status, and this object
is the working duplex status. while the port link status is down ,
then the speed status is unknown(3).
This attribute apply physical port and aggreate port"
::= { myIfEntry 8 }
myIfManageStatus OBJECT-TYPE
SYNTAX EnabledStatus
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Management status of the interface."
DEFVAL { enabled }
::={myIfEntry 9}
myIfIpBroadcast OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Broadcast address of the interface. if broadcast address not configured on interface, return 0.0.0.0"
::= { myIfEntry 10 }
myIfLayer OBJECT-TYPE
SYNTAX INTEGER {
layer-2(1), -- the interface is a interface of L2
layer-3(2) -- the interface is a interface of L3
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
""
::= { myIfEntry 11 }
myIfMode OBJECT-TYPE
SYNTAX INTEGER {
access(1), -- the mode of interface is access port
trunk(2), -- the mode of interface is trunk port
dot1q-tunnel(3), -- the mode of interface is 802.1q tunnel port
hybrid(4), -- the mode of interface is hybrid port
other(5), -- other mode
uplink(6), -- the mode of interface is uplink port
host(7), -- the mode of interface is private-vlan host port
promiscuous(8) -- the mode of interface is private-vlan promiscuous port
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This value is meaning for only physical port and aggreate port"
::= { myIfEntry 12 }
myIfCounterClear OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Setting its to any value but 0, will clear counters of this interface.
Setting its value to 0 will cause no action of the agent. and when
query will always return 0. "
::= { myIfEntry 13 }
myIfEntryStatus OBJECT-TYPE
SYNTAX ConfigStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Status of this entry, set this object to valid will create a interface,
and set its value to invalid will delete the interface of this entry."
::= { myIfEntry 14 }
myIfMediumType OBJECT-TYPE
SYNTAX INTEGER {
unknown(0),
copper(1),
fiber(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Port medium type of this port,fiber or copper."
::= { myIfEntry 15 }
myIfIpTable OBJECT-TYPE
SYNTAX SEQUENCE OF MyIfIpEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A list of interface ip configuration entries."
::= { myIfConfigMIBObjects 2}
myIfIpEntry OBJECT-TYPE
SYNTAX MyIfIpEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry containing configuration information applicable
to a Layer3 interface."
INDEX { myIfIpIfIndex, myIfIpId, myIfIp}
::= { myIfIpTable 1 }
MyIfIpEntry ::=
SEQUENCE {
myIfIpIfIndex IfIndex,
myIfIpId INTEGER,
myIfIp IpAddress,
myIfIpMask IpAddress,
myIfIpEntryStatus RowStatus
}
myIfIpIfIndex OBJECT-TYPE
SYNTAX IfIndex
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A unique value, for each Layer3 interface."
::= { myIfIpEntry 1 }
myIfIpId OBJECT-TYPE
SYNTAX INTEGER{
primary(1), -- primary ip address of Layer3 interface
secondary(2) -- secondary ip address of Layer3 interface
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Type of interface ip address."
::= { myIfIpEntry 2 }
myIfIp OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Ip address of the interface myIfIndex refer to."
::= { myIfIpEntry 3 }
myIfIpMask OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Ip mask of the interface ip address."
::= { myIfIpEntry 4 }
myIfIpEntryStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"entry status of this entry. and the means in this enviraments can
reffer to the text-convention definition of the RowStatus."
::= { myIfIpEntry 5 }
myIfStatusTable OBJECT-TYPE
SYNTAX SEQUENCE OF MyIfStatusEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"list of interface status. Status information include some error state and
result of examining to the interface,etc."
::= { myIfConfigMIBObjects 3 }
myIfStatusEntry OBJECT-TYPE
SYNTAX MyIfStatusEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Entry contains interface status information."
INDEX { myIfStatusIndex }
::= { myIfStatusTable 1 }
MyIfStatusEntry ::=
SEQUENCE {
myIfStatusIndex IfIndex,
myIfStatusLoopBackExamine Integer32,
myIfErrorStatus INTEGER,
myIfLineDetect Integer32
}
myIfStatusIndex OBJECT-TYPE
SYNTAX IfIndex
MAX-ACCESS read-only
STATUS current
DESCRIPTION
" "
::= { myIfStatusEntry 1 }
myIfStatusLoopBackExamine OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Setting its to any value but 0, will Checking whether this port or aggreate can
receive and send packets normally, It indicates that port or aggreate is normal
if opertion is success.
Setting its value to 0 will cause no action of the agent. and when
query will always return 0.
This attribute apply physical port and aggreate port"
::= { myIfStatusEntry 2 }
myIfErrorStatus OBJECT-TYPE
SYNTAX INTEGER {
no-error(1), -- port is enabled normal
err-disable-bpduguard(2), -- port is disabled by port receive BPDU packet when port
-- enable BPDU guard
err-disable-ptsecurity(3) -- port is disabled by port security is violatd
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Port's error status information"
::= { myIfStatusEntry 3 }
myIfLineDetect OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"When reading this object, system detects the quality of line connecting the port.
Detect whether the line is broken or short circuit or not.
The meaning of the obtained value:
Return value=N*10000000+M
N stands for the line state (0: perfect; 1: break; 2: short circuit)
M stands for the location of the break or short circuit in the line(distance from the switch port, in metre)
If the line is perfect, the value is zero."
::= { myIfStatusEntry 4 }
myGlobalIfDisableRecovery OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Setting its to any value but 0, the interfaces which is shutted down by
some error happened will recovery from disabled status .
Setting its value to 0 will cause no action of the agent. and when
query will always return 0.
This attribute apply physical port and aggreate port"
::= { myIfConfigMIBObjects 4 }
--
-- portType Choose
--
myPortTypeChooseTable OBJECT-TYPE
SYNTAX SEQUENCE OF MyPortTypeChooseEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Table of entrance to choose port type."
::= { myIfConfigMIBObjects 5 }
myPortTypeChooseEntry OBJECT-TYPE
SYNTAX MyPortTypeChooseEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Entrance to choose port type."
INDEX { myPortTypeChooseIndex }
::= { myPortTypeChooseTable 1 }
MyPortTypeChooseEntry ::=
SEQUENCE {
myPortTypeChooseIndex IfIndex,
myPortTypeChooseType INTEGER
}
myPortTypeChooseIndex OBJECT-TYPE
SYNTAX IfIndex
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The logic port number."
::= { myPortTypeChooseEntry 1 }
myPortTypeChooseType OBJECT-TYPE
SYNTAX INTEGER {
fiber(1), --priority of fiber port
copper(2) --priority of copper port
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The chosen port type. This object is used to choose one of the multiple physical ports of different types,
when the same logical port is correspondent with them.
Apply this attribute to the physical port only."
::= { myPortTypeChooseEntry 2 }
--
-- mtu
--
myIfMTUTable OBJECT-TYPE
SYNTAX SEQUENCE OF MyIfMTUEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Access table of MTU on interface."
::= { myIfConfigMIBObjects 6 }
myIfMTUEntry OBJECT-TYPE
SYNTAX MyIfMTUEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Interfac MTU access."
INDEX { myIfMTUIndex }
::= { myIfMTUTable 1 }
MyIfMTUEntry ::=
SEQUENCE {
myIfMTUIndex IfIndex,
myIfMTU Integer32
}
myIfMTUIndex OBJECT-TYPE
SYNTAX IfIndex
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Interface number"
::= { myIfMTUEntry 1 }
myIfMTU OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Interface MTU."
::= { myIfMTUEntry 2 }
--
-- Available Bandwidth
--
myIfAvailableBWTable OBJECT-TYPE
SYNTAX SEQUENCE OF MyIfAvailableBWEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Access table of Available Bandwidth on interface."
::= { myIfConfigMIBObjects 7 }
myIfAvailableBWEntry OBJECT-TYPE
SYNTAX MyIfAvailableBWEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Interfac available bandwidth access."
INDEX { myIfAvailableBWIfIndex }
::= { myIfAvailableBWTable 1 }
MyIfAvailableBWEntry ::=
SEQUENCE {
myIfAvailableBWIfIndex IfIndex,
myIfAvailableBWIfBW Gauge
}
myIfAvailableBWIfIndex OBJECT-TYPE
SYNTAX IfIndex
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Interface number"
::= { myIfAvailableBWEntry 1 }
myIfAvailableBWIfBW OBJECT-TYPE
SYNTAX Gauge
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Interface available bandwidth(bit)."
::= { myIfAvailableBWEntry 2 }
-- Notification
myInterfaceTraps OBJECT IDENTIFIER ::= { myInterfaceMIB 2 }
lineDetectStatus OBJECT-TYPE
SYNTAX INTEGER{
ok(1), --line has restored to normal state
open(2), --a break in the line
short(3) --short circuit in the line
}
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"The type of storm of interface"
::= { myInterfaceTraps 1 }
lineDetectPosition OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"Location where the break or short circuit in the line happens
(Distance from the switch port, in metre.)"
::= { myInterfaceTraps 2 }
lineQualityDetect NOTIFICATION-TYPE
OBJECTS {ifIndex, lineDetectStatus,lineDetectPosition}
STATUS current
DESCRIPTION
"The notification of discovering a break or short circuit in the line,
or restoring the line to the normal state."
::= { myInterfaceTraps 3 }
myInterfaceMIBConformance OBJECT IDENTIFIER ::= { myInterfaceMIB 3 }
myInterfaceMIBCompliances OBJECT IDENTIFIER ::= { myInterfaceMIBConformance 1 }
myInterfaceMIBGroups OBJECT IDENTIFIER ::= { myInterfaceMIBConformance 2 }
-- compliance statements
myInterfaceMIBCompliance MODULE-COMPLIANCE
STATUS current
DESCRIPTION
"The compliance statement for entities which implement
the My Interface MIB"
MODULE -- this module
MANDATORY-GROUPS { myInterfaceMIBGroup
}
GROUP myPortTypeChooseMibGroup
DESCRIPTION
"This group is mandatory when system supports optional port type."
GROUP myIfMTUMibGroup
DESCRIPTION
"This group is mandatory when system supports MTU setting."
GROUP myIfLineDetectGroup
DESCRIPTION
"This group is mandatory when system supports line quality detection."
GROUP myIfAvailableBWMibGroup
DESCRIPTION
"This group is mandatory when system supports available bandwidth getting."
::= { myInterfaceMIBCompliances 1 }
-- units of conformance
myInterfaceMIBGroup OBJECT-GROUP
OBJECTS {
myIfIndex,
myIfPortType,
myIfFlowControlAdminStatus,
myIfFlowControlOperStatus,
myIfAdminSpeed,
myIfAdminDuplex,
myIfOperSpeed,
myIfOperDuplex,
myIfManageStatus,
myIfIpBroadcast,
myIfLayer,
myIfMode,
myIfCounterClear,
myIfEntryStatus,
myIfMediumType,
myIfIpIfIndex,
myIfIpId,
myIfIp,
myIfIpMask,
myIfIpEntryStatus,
myIfStatusIndex,
myIfStatusLoopBackExamine,
myIfErrorStatus,
myGlobalIfDisableRecovery
}
STATUS current
DESCRIPTION
"A collection of objects providing interface basic configure ."
::= { myInterfaceMIBGroups 1 }
myPortTypeChooseMibGroup OBJECT-GROUP
OBJECTS {
myPortTypeChooseIndex,
myPortTypeChooseType
}
STATUS current
DESCRIPTION
"Information collection of choosing port type."
::= { myInterfaceMIBGroups 2 }
myIfMTUMibGroup OBJECT-GROUP
OBJECTS {
myIfMTUIndex,
myIfMTU
}
STATUS current
DESCRIPTION
"Interface MTU information collection."
::= { myInterfaceMIBGroups 3 }
myIfLineDetectGroup OBJECT-GROUP
OBJECTS {
myIfLineDetect
}
STATUS current
DESCRIPTION
"Information collection of line quality detection."
::= { myInterfaceMIBGroups 4 }
myIfAvailableBWMibGroup OBJECT-GROUP
OBJECTS {
myIfAvailableBWIfIndex,
myIfAvailableBWIfBW
}
STATUS current
DESCRIPTION
"Interface available bandwidth information collection."
::= { myInterfaceMIBGroups 5 }
END