Observium_CE/mibs/riverdelta/RDN-EVT-NOTIFICATIONS

937 lines
33 KiB
Plaintext

-- *****************************************************************
-- RDN-EVT-NOTIFICATIONS.mib:
-- Motorola BSR's EVT Notifications MIB
--
-- Copyright (C) 2003, 2008 by Motorola, Inc.
-- All rights reserved.
-- *****************************************************************
RDN-EVT-NOTIFICATIONS DEFINITIONS::= BEGIN
IMPORTS
riverdelta
FROM RDN-MIB
ifPhysAddress
FROM IF-MIB
docsIfDocsisBaseCapability
FROM DOCS-IF-MIB
docsDevEvId,
docsDevEvText,
docsDevEvLevel
FROM DOCS-CABLE-DEVICE-MIB
NOTIFICATION-TYPE,
MODULE-IDENTITY
FROM SNMPv2-SMI;
rdnEvtNotifications MODULE-IDENTITY
LAST-UPDATED "200808080000Z" -- August 8, 2008
ORGANIZATION "Motorola"
CONTACT-INFO "Motorola
Customer Service
101 Tournament Drive
Horsham, PA 19044
US Tel: +1 888 944 4357
Int Tel: +1 215 323 0044
Fax: +1 215 323 1502
Email: CPSSupport@Motorola.com"
DESCRIPTION
"MIB module for EVT Notifications. The following notifications
are generated by EVTs. The Event Id for each event is represented
as the last sub identifier for each notification.
The DOCSIS Event Id(docsDevEvId) or last sub-identifier is
calculated by adding the Motorola Event Id Base + Vendor Specific
Event Base + + the EVT subsystem base + index (1-255).
Example of DRM.56 'Spare CMTS Active' event identifier is:
Vendor Event Id Base 0x80000000
Motorola Event Base + 0x13750000
DRM Evt subsystem Base + 0x 700
56 (in hex) + 0x 38
----------
0x93750738 hex
or 2473920312 decimal
The CLI command 'show evt' also displays the bases for the EVT
subsystems that are registered.
All EVT notifications contain the same set variable-bindings:
docsDevEvLevel - this event's severity level.
docsDevEvId - the DOSIS Event Id for this particular event,
and also the last sub identifier for this notification.
docsDevEvText - The DOCSIS Event Text for this event,
ASCII printable text that is displayed for this event.
docsIfDocsisBaseCapability - The current DOCSIS capabilities of
this agent.
ifPhysAddress - Not used at this time.
This MIB just list a few of the notifications generated by EVT,
specifically all EVTs notification with a severity level of
critical or higher.
Copyright (C) 2003, 2008 by Motorola, Inc.
All rights reserved."
REVISION "200808080000Z" -- 08 August 2008
DESCRIPTION
"Added Copyright Statement into MIB modules's
description."
REVISION "200402200000Z" -- February 20, 2004
DESCRIPTION
"Correct the follow Object Identifiers:
* rdnEvtDraRxUnexpectedMsgSubType is 2473919755 (DRA.11)
* rdnEvtDraTmrInitFailure is 247391961 (DRA.17)
* rdnEvtDraInvalidFuncParam is 2473919767 (DRA.23)
* rdnEvtDraInvalidMsgParam is 2473919768 (DRA.24)"
REVISION "200311050000Z" -- November 5, 2003
DESCRIPTION
"Updated the CONTACT-INFO."
REVISION "200307090000Z" -- July 9, 2003
DESCRIPTION
"Initial creation."
::= { riverdelta 0 }
rdnEvtMacrtrGetQIdFailure NOTIFICATION-TYPE
OBJECTS { docsDevEvLevel,
docsDevEvId,
docsDevEvText,
docsIfDocsisBaseCapability,
ifPhysAddress }
STATUS current
DESCRIPTION
"This is an internal software error.
The MACRTR task was unable to get the DOCSIS Redundancy Agent(DRA)
task main message queue id."
::= { rdnEvtNotifications 2473918722 }
rdnEvtMacrtrUnknownCase NOTIFICATION-TYPE
OBJECTS { docsDevEvLevel,
docsDevEvId,
docsDevEvText,
docsIfDocsisBaseCapability,
ifPhysAddress }
STATUS current
DESCRIPTION
"This is an internal software error. The MACRTR task was received
an unexpected case, which is not handled."
::= { rdnEvtNotifications 2473918723 }
rdnEvtMacrtrMsgQReceiveFailure NOTIFICATION-TYPE
OBJECTS { docsDevEvLevel,
docsDevEvId,
docsDevEvText,
docsIfDocsisBaseCapability,
ifPhysAddress }
STATUS current
DESCRIPTION
"This is an internal software error. The MACRTR task caught an error
when it was receiving a message."
::= { rdnEvtNotifications 2473918724 }
rdnEvtMacrtrRdbDefineTableFailure NOTIFICATION-TYPE
OBJECTS { docsDevEvLevel,
docsDevEvId,
docsDevEvText,
docsIfDocsisBaseCapability,
ifPhysAddress }
STATUS current
DESCRIPTION
"This is an internal software error. The MACRTR task was unable
to register a table with the Redundancy Runtime Record
Database(RDB) for CMTS Redundancy."
::= { rdnEvtNotifications 2473918726 }
rdnEvtMacrtrRxUnexpectedMsgType NOTIFICATION-TYPE
OBJECTS { docsDevEvLevel,
docsDevEvId,
docsDevEvText,
docsIfDocsisBaseCapability,
ifPhysAddress }
STATUS current
DESCRIPTION
"This is an internal software error. The MACRTR task received an
unexpected message type."
::= { rdnEvtNotifications 2473918730 }
rdnEvtMacrtrRegTaskMonFailure NOTIFICATION-TYPE
OBJECTS { docsDevEvLevel,
docsDevEvId,
docsDevEvText,
docsIfDocsisBaseCapability,
ifPhysAddress }
STATUS current
DESCRIPTION
"This is an internal software error. The MACRTR task was unable to
register with the task monitor."
::= { rdnEvtNotifications 2473918731 }
rdnEvtMacrtrInvalidFuncParam NOTIFICATION-TYPE
OBJECTS { docsDevEvLevel,
docsDevEvId,
docsDevEvText,
docsIfDocsisBaseCapability,
ifPhysAddress }
STATUS current
DESCRIPTION
"This is an internal software error. The MACRTR task detected an
invalid function parameter."
::= { rdnEvtNotifications 2473918732 }
rdnEvtMacrtrUnknownCmId NOTIFICATION-TYPE
OBJECTS { docsDevEvLevel,
docsDevEvId,
docsDevEvText,
docsIfDocsisBaseCapability,
ifPhysAddress }
STATUS current
DESCRIPTION
"This is an internal software error. During a CMTS Switchover,
the MACRTR task was unable to determine the cable modem Id when
loading the Cable Modem runtime record. This notification is only
generated on the BSR 64000."
::= { rdnEvtNotifications 2473918735 }
rdnEvtBpiLoadAuthRunRecFailure NOTIFICATION-TYPE
OBJECTS { docsDevEvLevel,
docsDevEvId,
docsDevEvText,
docsIfDocsisBaseCapability,
ifPhysAddress }
STATUS current
DESCRIPTION
"This is an internal software error. The Baseline Privacy
Interface(BPI) task was unable to load the Authorization Key
runtime record during a CMTS Switchover."
::= { rdnEvtNotifications 2473919513 }
rdnEvtBpiLoadTekRunRecFailure NOTIFICATION-TYPE
OBJECTS { docsDevEvLevel,
docsDevEvId,
docsDevEvText,
docsIfDocsisBaseCapability,
ifPhysAddress }
STATUS current
DESCRIPTION
"This is an internal software error. The Baseline Privacy
Interface(BPI) task was unable to load the TEK runtime
record during a CMTS Switchover."
::= { rdnEvtNotifications 2473919514 }
rdnEvtBpiLoadCmCertificateFailure NOTIFICATION-TYPE
OBJECTS { docsDevEvLevel,
docsDevEvId,
docsDevEvText,
docsIfDocsisBaseCapability,
ifPhysAddress }
STATUS current
DESCRIPTION
"This is an internal software error. The Baseline Privacy
Interface(BPI) task was unable to load the Cable Modem
Certificate during a CMTS Switchover."
::= { rdnEvtNotifications 2473919525 }
rdnEvtDraTaskSpawnFailure NOTIFICATION-TYPE
OBJECTS { docsDevEvLevel,
docsDevEvId,
docsDevEvText,
docsIfDocsisBaseCapability,
ifPhysAddress }
STATUS current
DESCRIPTION
"This is an internal software error. Unable to create the
DOCSIS Redundancy Agent(DRA) task. This notification is only
generated on the BSR 64000."
::= { rdnEvtNotifications 2473919745 }
rdnEvtDraMsgQCreateFailure NOTIFICATION-TYPE
OBJECTS { docsDevEvLevel,
docsDevEvId,
docsDevEvText,
docsIfDocsisBaseCapability,
ifPhysAddress }
STATUS current
DESCRIPTION
"This is an internal software error. Unable to create the DRA task's
message queue. This notification is only generated on the BSR 64000."
::= { rdnEvtNotifications 2473919746 }
rdnEvtDraMsgQReceiveFailure NOTIFICATION-TYPE
OBJECTS { docsDevEvLevel,
docsDevEvId,
docsDevEvText,
docsIfDocsisBaseCapability,
ifPhysAddress }
STATUS current
DESCRIPTION
"This is an internal software error. DRA task's caught an error
when it was receiving a message. This notification is only
generated on the BSR 64000."
::= { rdnEvtNotifications 2473919747 }
rdnEvtDraRegTaskMonFailure NOTIFICATION-TYPE
OBJECTS { docsDevEvLevel,
docsDevEvId,
docsDevEvText,
docsIfDocsisBaseCapability,
ifPhysAddress }
STATUS current
DESCRIPTION
"This is an internal software error. DRA task was unable to register
with the task monitor. This notification is only
generated on the BSR 64000."
::= { rdnEvtNotifications 2473919748 }
rdnEvtDraCreateRdbFailure NOTIFICATION-TYPE
OBJECTS { docsDevEvLevel,
docsDevEvId,
docsDevEvText,
docsIfDocsisBaseCapability,
ifPhysAddress }
STATUS current
DESCRIPTION
"This is an internal software error. DRA task was
unable to create a Redundancy Runtime Database for CMTS Redundancy.
This notification is only generated on the BSR 64000."
::= { rdnEvtNotifications 2473919749 }
rdnEvtDraRxUnexpectedMsgType NOTIFICATION-TYPE
OBJECTS { docsDevEvLevel,
docsDevEvId,
docsDevEvText,
docsIfDocsisBaseCapability,
ifPhysAddress }
STATUS current
DESCRIPTION
"This is an internal software error. DRA task received an unexpected
message type. This notification is only generated on the BSR 64000."
::= { rdnEvtNotifications 2473919754 }
rdnEvtDraRxUnexpectedMsgSubType NOTIFICATION-TYPE
OBJECTS { docsDevEvLevel,
docsDevEvId,
docsDevEvText,
docsIfDocsisBaseCapability,
ifPhysAddress }
STATUS current
DESCRIPTION
"This is an internal software error. DRA task received an unexpected
message sub-type. This notification is only generated on the
BSR 64000."
::= { rdnEvtNotifications 2473919755 }
rdnEvtDraTmrInitFailure NOTIFICATION-TYPE
OBJECTS { docsDevEvLevel,
docsDevEvId,
docsDevEvText,
docsIfDocsisBaseCapability,
ifPhysAddress }
STATUS current
DESCRIPTION
"This is an internal software error. DRA was unable to
create its timers. This notification is only generated
on the BSR 64000."
::= { rdnEvtNotifications 2473919761 }
rdnEvtDraInvalidFuncParam NOTIFICATION-TYPE
OBJECTS { docsDevEvLevel,
docsDevEvId,
docsDevEvText,
docsIfDocsisBaseCapability,
ifPhysAddress }
STATUS current
DESCRIPTION
"This is an internal software error. The DRA task detected an
invalid function parameter. This notification is only generated
on the BSR 64000."
::= { rdnEvtNotifications 2473919767 }
rdnEvtDraInvalidMsgParam NOTIFICATION-TYPE
OBJECTS { docsDevEvLevel,
docsDevEvId,
docsDevEvText,
docsIfDocsisBaseCapability,
ifPhysAddress }
STATUS current
DESCRIPTION
"This is an internal software error. The DRA task detected an
invalid message parameter. This notification is only generated
on the BSR 64000."
::= { rdnEvtNotifications 2473919768 }
rdnEvtRdbMsgQCheckFailure NOTIFICATION-TYPE
OBJECTS { docsDevEvLevel,
docsDevEvId,
docsDevEvText,
docsIfDocsisBaseCapability,
ifPhysAddress }
STATUS current
DESCRIPTION
"This is an internal resource error. The is a major component
failure with on of RDB's message queues, that may lead to
system failures. Try correcting this problem by resetting this
CMTS. This notification is only generated on the BSR 64000."
::= { rdnEvtNotifications 2473920006 }
rdnEvtRdbCreateDatabaseFailure NOTIFICATION-TYPE
OBJECTS { docsDevEvLevel,
docsDevEvId,
docsDevEvText,
docsIfDocsisBaseCapability,
ifPhysAddress }
STATUS current
DESCRIPTION
"This is an internal error. There is a major component
failure creating a database for CMTS redundancy, this could
lead to system failures. This notification is only generated
on the BSR 64000."
::= { rdnEvtNotifications 2473920025 }
rdnEvtRdbInitDatabaseFailure NOTIFICATION-TYPE
OBJECTS { docsDevEvLevel,
docsDevEvId,
docsDevEvText,
docsIfDocsisBaseCapability,
ifPhysAddress }
STATUS current
DESCRIPTION
"This is an internal error. There is a major component
failure initializing a database for CMTS redundancy, this could
lead to system failures. This notification is only generated
on the BSR 64000."
::= { rdnEvtNotifications 2473920026 }
rdnEvtRdbSemCreateFailure NOTIFICATION-TYPE
OBJECTS { docsDevEvLevel,
docsDevEvId,
docsDevEvText,
docsIfDocsisBaseCapability,
ifPhysAddress }
STATUS current
DESCRIPTION
"This is an internal software error. RDB task was unable to create
a semaphore for mutual exclusion. This notification is only generated
on the BSR 64000."
::= { rdnEvtNotifications 2473920048 }
rdnEvtRdbUnknownTableFromPeer NOTIFICATION-TYPE
OBJECTS { docsDevEvLevel,
docsDevEvId,
docsDevEvText,
docsIfDocsisBaseCapability,
ifPhysAddress }
STATUS current
DESCRIPTION
"Software versions may not be the same on the Primary and
the Spare. This may cause a loss of data on replications of
the redundancy databases and lead to serious problem on a
switchover. Upgrade the software so that the Primary and Spare
have matching software versions."
::= { rdnEvtNotifications 2473920145 }
rdnEvtRdbDefineTableNotEnoughMemory NOTIFICATION-TYPE
OBJECTS { docsDevEvLevel,
docsDevEvId,
docsDevEvText,
docsIfDocsisBaseCapability,
ifPhysAddress }
STATUS current
DESCRIPTION
"Not Enough Memory to register a new table with RDB. This could
lead loss of data on replications of the redundancy databases and
lead to serious problem on a switchovers."
::= { rdnEvtNotifications 2473920174 }
rdnEvtRdbMsgBufAllocFailure NOTIFICATION-TYPE
OBJECTS { docsDevEvLevel,
docsDevEvId,
docsDevEvText,
docsIfDocsisBaseCapability,
ifPhysAddress }
STATUS current
DESCRIPTION
"Not Enough Memory to create message buffers in RDB. This could
lead loss of data on replications of the redundancy databases and
lead to serious problem on a switchovers. Reset the card
reporting this problem."
::= { rdnEvtNotifications 2473920179 }
rdnEvtRdbMemPoolAllocFailure NOTIFICATION-TYPE
OBJECTS { docsDevEvLevel,
docsDevEvId,
docsDevEvText,
docsIfDocsisBaseCapability,
ifPhysAddress }
STATUS current
DESCRIPTION
"Not Enough Memory to create storage for the runtime records.
This could lead to loss of data on replications of the
redundancy databases and lead to serious problems on a switchover."
::= { rdnEvtNotifications 2473920185 }
rdnEvtRdbMallocFailure NOTIFICATION-TYPE
OBJECTS { docsDevEvLevel,
docsDevEvId,
docsDevEvText,
docsIfDocsisBaseCapability,
ifPhysAddress }
STATUS current
DESCRIPTION
"Memory allocation for internal RDB structure reported an error.
This card is most like running low on memory. Reset the card
reporting this problem."
::= { rdnEvtNotifications 2473920186 }
rdnEvtDrmSpareCmtsActive NOTIFICATION-TYPE
OBJECTS { docsDevEvLevel,
docsDevEvId,
docsDevEvText,
docsIfDocsisBaseCapability,
ifPhysAddress }
STATUS current
DESCRIPTION
"This is reported when a Spare CMTS becomes active
for a redundant primary CMTS in a BSR 64000 chassis."
::= { rdnEvtNotifications 2473920312 }
rdnEvtDrmFailedAutoTakeover NOTIFICATION-TYPE
OBJECTS { docsDevEvLevel,
docsDevEvId,
docsDevEvText,
docsIfDocsisBaseCapability,
ifPhysAddress }
STATUS current
DESCRIPTION
"This is reported when a Primary CMTS goes down, and
an auto-takeover fails to make Spare CMTS become the
active CMTS in a BSR 64000 chassis."
::= { rdnEvtNotifications 2473920313 }
rdnEvtDrmFailedAutoGiveback NOTIFICATION-TYPE
OBJECTS { docsDevEvLevel,
docsDevEvId,
docsDevEvText,
docsIfDocsisBaseCapability,
ifPhysAddress }
STATUS current
DESCRIPTION
"This is reported when a active Spare CMTS goes down, and
an auto-giveback fails to make Primary CMTS become the
active CMTS in a BSR 64000 chassis."
::= { rdnEvtNotifications 2473920314 }
rdnEvtDrmSpareXmittersRcvrsMismatch NOTIFICATION-TYPE
OBJECTS { docsDevEvLevel,
docsDevEvId,
docsDevEvText,
docsIfDocsisBaseCapability,
ifPhysAddress }
STATUS current
DESCRIPTION
"This is reported when Spare CMTS has fewer transmitters or
receivers than a Primary CMTS. The Spare CMTS must have at
least as many transmitters and receivers as each Primary CMTS
in order to have successful CMTS switchovers in a
BSR 64000 chassis."
::= { rdnEvtNotifications 2473920315 }
rdnEvtDrmSpareDtxActive NOTIFICATION-TYPE
OBJECTS { docsDevEvLevel,
docsDevEvId,
docsDevEvText,
docsIfDocsisBaseCapability,
ifPhysAddress }
STATUS current
DESCRIPTION
"This is reported when a Spare DTX becomes active
for a redundant primary DTX in a BSR 64000 chassis."
::= { rdnEvtNotifications 2473920431}
rdnEvtDrmFailedDtxAutoTakeover NOTIFICATION-TYPE
OBJECTS { docsDevEvLevel,
docsDevEvId,
docsDevEvText,
docsIfDocsisBaseCapability,
ifPhysAddress }
STATUS current
DESCRIPTION
"This is reported when a Primary DTX goes down, and
an auto-takeover fails to make Spare DTX become the
active DTX in a BSR 64000 chassis."
::= { rdnEvtNotifications 2473920432}
rdnEvtDrmFailedDtxAutoGiveback NOTIFICATION-TYPE
OBJECTS { docsDevEvLevel,
docsDevEvId,
docsDevEvText,
docsIfDocsisBaseCapability,
ifPhysAddress }
STATUS current
DESCRIPTION
"This is reported when a active Spare DTX goes down, and
an auto-giveback fails to make Primary DTX become the
active DTX in a BSR 64000 chassis."
::= { rdnEvtNotifications 2473920433}
rdnEvtDrmSpareDrxActive NOTIFICATION-TYPE
OBJECTS { docsDevEvLevel,
docsDevEvId,
docsDevEvText,
docsIfDocsisBaseCapability,
ifPhysAddress }
STATUS current
DESCRIPTION
"This is reported when a Spare DRX becomes active
for a redundant primary DRX in a BSR 64000 chassis."
::= { rdnEvtNotifications 2473920441}
rdnEvtDrmFailedDrxAutoTakeover NOTIFICATION-TYPE
OBJECTS { docsDevEvLevel,
docsDevEvId,
docsDevEvText,
docsIfDocsisBaseCapability,
ifPhysAddress }
STATUS current
DESCRIPTION
"This is reported when a Primary DRX goes down, and
an auto-takeover fails to make Spare DRX become the
active DRX in a BSR 64000 chassis."
::= { rdnEvtNotifications 2473920442}
rdnEvtDrmFailedDrxAutoGiveback NOTIFICATION-TYPE
OBJECTS { docsDevEvLevel,
docsDevEvId,
docsDevEvText,
docsIfDocsisBaseCapability,
ifPhysAddress }
STATUS current
DESCRIPTION
"This is reported when a active Spare DRX goes down, and
an auto-giveback fails to make Primary DRX become the
active DRX in a BSR 64000 chassis."
::= { rdnEvtNotifications 2473920443}
rdnEvtAccrtrRdbDefineTableFailure NOTIFICATION-TYPE
OBJECTS { docsDevEvLevel,
docsDevEvId,
docsDevEvText,
docsIfDocsisBaseCapability,
ifPhysAddress }
STATUS current
DESCRIPTION
"This is an internal software error. The Accrtr task was unable
to register a table with the Redundancy Runtime Record
Database(RDB) for CMTS Redundancy."
::= { rdnEvtNotifications 2473920769 }
rdnEvtAccrtrRdbNextFailure NOTIFICATION-TYPE
OBJECTS { docsDevEvLevel,
docsDevEvId,
docsDevEvText,
docsIfDocsisBaseCapability,
ifPhysAddress }
STATUS current
DESCRIPTION
"This is an internal software error. The Accrtr task was unable
retrieve the next runtime record from Redundancy Runtime Record
Database(RDB) for CMTS Redundancy."
::= { rdnEvtNotifications 2473920775 }
rdnEvtAccrtrNotFrozenLoad NOTIFICATION-TYPE
OBJECTS { docsDevEvLevel,
docsDevEvId,
docsDevEvText,
docsIfDocsisBaseCapability,
ifPhysAddress }
STATUS current
DESCRIPTION
"This is an internal software error. The Accrtr task was not frozen
when trying to load the runtime records for a particular cable
modem during a CMTS Switchover."
::= { rdnEvtNotifications 2473920781 }
rdnEvtArdrtrRdbDefineTableFailure NOTIFICATION-TYPE
OBJECTS { docsDevEvLevel,
docsDevEvId,
docsDevEvText,
docsIfDocsisBaseCapability,
ifPhysAddress }
STATUS current
DESCRIPTION
"This is an internal software error. The Address Resolution
Database Run Time Records(Ardrtr) task was unable
to register a table with the Redundancy Runtime Record
Database(RDB) for CMTS Redundancy."
::= { rdnEvtNotifications 2473921025 }
rdnEvtArdrtrRdbNextFailure NOTIFICATION-TYPE
OBJECTS { docsDevEvLevel,
docsDevEvId,
docsDevEvText,
docsIfDocsisBaseCapability,
ifPhysAddress }
STATUS current
DESCRIPTION
"This is an internal software error. The Address Resolution
Database Run Time Records(Ardrtr) task was unable
retrieve the next runtime record from Redundancy Runtime Record
Database(RDB) for CMTS Redundancy."
::= { rdnEvtNotifications 2473921031 }
rdnEvtArdrtrNotFrozenLoad NOTIFICATION-TYPE
OBJECTS { docsDevEvLevel,
docsDevEvId,
docsDevEvText,
docsIfDocsisBaseCapability,
ifPhysAddress }
STATUS current
DESCRIPTION
"This is an internal software error. The Address Resolution
Database Run Time Records(Ardrtr) task was not frozen
when trying to load the runtime records for a particular cable
modem during a CMTS Switchover."
::= { rdnEvtNotifications 2473921035 }
rdnEvtArdrtrLoadFailure NOTIFICATION-TYPE
OBJECTS { docsDevEvLevel,
docsDevEvId,
docsDevEvText,
docsIfDocsisBaseCapability,
ifPhysAddress }
STATUS current
DESCRIPTION
"This is an internal software error. The Address Resolution
Database Run Time Records(Ardrtr) task was unable to load
the runtime records do to an invalid cable modem Id during a
CMTS Switchover."
::= { rdnEvtNotifications 2473921039 }
rdnEvtMacmgrValidateCmError NOTIFICATION-TYPE
OBJECTS { docsDevEvLevel,
docsDevEvId,
docsDevEvText,
docsIfDocsisBaseCapability,
ifPhysAddress }
STATUS current
DESCRIPTION
"This is an internal software error. The Macmgr task received
a 'Validate Cable Modem' message from BPI, which contained an
invalid cable modem index."
::= { rdnEvtNotifications 2473921541 }
rdnEvtMacmgrInvalidateCmError NOTIFICATION-TYPE
OBJECTS { docsDevEvLevel,
docsDevEvId,
docsDevEvText,
docsIfDocsisBaseCapability,
ifPhysAddress }
STATUS current
DESCRIPTION
"This is an internal software error. The Macmgr task received
a 'Invalidate Cable Modem' message from BPI, which contained an
invalid cable modem index."
::= { rdnEvtNotifications 2473921568 }
rdnEvtMacmgrNullPtr NOTIFICATION-TYPE
OBJECTS { docsDevEvLevel,
docsDevEvId,
docsDevEvText,
docsIfDocsisBaseCapability,
ifPhysAddress }
STATUS current
DESCRIPTION
"This is an internal software error. The Macmgr task called a
function with a null pointer."
::= { rdnEvtNotifications 2473921577 }
rdnEvtDocsifCmtsCmIndexAddFreeListFailure NOTIFICATION-TYPE
OBJECTS { docsDevEvLevel,
docsDevEvId,
docsDevEvText,
docsIfDocsisBaseCapability,
ifPhysAddress }
STATUS current
DESCRIPTION
"This is an internal software error. Unable to add
the docsIfCmtsCmStatusIndex to a list of indexes available to use."
::= { rdnEvtNotifications 2473924360 }
rdnEvtDocsifCmtsCmIndexDelFreeListFailure NOTIFICATION-TYPE
OBJECTS { docsDevEvLevel,
docsDevEvId,
docsDevEvText,
docsIfDocsisBaseCapability,
ifPhysAddress }
STATUS current
DESCRIPTION
"This is an internal software error. Unable to remove
the docsIfCmtsCmStatusIndex from a list of indexes available to use."
::= { rdnEvtNotifications 2473924362 }
rdnEvtDocsifCmtsCmIndexReloadFreeListFailure NOTIFICATION-TYPE
OBJECTS { docsDevEvLevel,
docsDevEvId,
docsDevEvText,
docsIfDocsisBaseCapability,
ifPhysAddress }
STATUS current
DESCRIPTION
"This is an internal software error. Unable to reload
the docsIfCmtsCmStatusIndex from a list of indexes available to use."
::= { rdnEvtNotifications 2473924371 }
rdnEvtUpcTaskSpawnFailure NOTIFICATION-TYPE
OBJECTS { docsDevEvLevel,
docsDevEvId,
docsDevEvText,
docsIfDocsisBaseCapability,
ifPhysAddress }
STATUS current
DESCRIPTION
"This is an internal software error. Unable to create the
Up Converter(UPC) task."
::= { rdnEvtNotifications 2473925121 }
rdnEvtUpcMsgQCreateFailure NOTIFICATION-TYPE
OBJECTS { docsDevEvLevel,
docsDevEvId,
docsDevEvText,
docsIfDocsisBaseCapability,
ifPhysAddress }
STATUS current
DESCRIPTION
"This is an internal software error. Unable to create the UPC task's
message queue."
::= { rdnEvtNotifications 2473925122 }
rdnEvtUpcMsgQReceiveFailure NOTIFICATION-TYPE
OBJECTS { docsDevEvLevel,
docsDevEvId,
docsDevEvText,
docsIfDocsisBaseCapability,
ifPhysAddress }
STATUS current
DESCRIPTION
"This is an internal software error. UPC task's caught an error
when it was receiving a message."
::= { rdnEvtNotifications 2473925123 }
rdnEvtUpcRegTaskMonFailure NOTIFICATION-TYPE
OBJECTS { docsDevEvLevel,
docsDevEvId,
docsDevEvText,
docsIfDocsisBaseCapability,
ifPhysAddress }
STATUS current
DESCRIPTION
"This is an internal software error. UPC task was unable to register
with the task monitor."
::= { rdnEvtNotifications 2473925124 }
rdnEvtUpcRxUnexpectedMsgType NOTIFICATION-TYPE
OBJECTS { docsDevEvLevel,
docsDevEvId,
docsDevEvText,
docsIfDocsisBaseCapability,
ifPhysAddress }
STATUS current
DESCRIPTION
"This is an internal software error. UPC task received an unexpected
message type."
::= { rdnEvtNotifications 2473925126 }
rdnEvtUpcRxUnexpectedMsgSubType NOTIFICATION-TYPE
OBJECTS { docsDevEvLevel,
docsDevEvId,
docsDevEvText,
docsIfDocsisBaseCapability,
ifPhysAddress }
STATUS current
DESCRIPTION
"This is an internal software error. UPC task received an unexpected
message sub-type."
::= { rdnEvtNotifications 2473925127 }
rdnEvtUpcSemCreateFailure NOTIFICATION-TYPE
OBJECTS { docsDevEvLevel,
docsDevEvId,
docsDevEvText,
docsIfDocsisBaseCapability,
ifPhysAddress }
STATUS current
DESCRIPTION
"This is an internal software error. UPC task was unable to create a
semaphore for mutual exclusion."
::= { rdnEvtNotifications 2473925142 }
rdnEvtSvcfloNullPtr NOTIFICATION-TYPE
OBJECTS { docsDevEvLevel,
docsDevEvId,
docsDevEvText,
docsIfDocsisBaseCapability,
ifPhysAddress }
STATUS current
DESCRIPTION
"This is an internal software error. The SVCFLO task called a
function will a null pointer."
::= { rdnEvtNotifications 2473925891 }
rdnEvtSvcfloWriteNextFlowTlvError NOTIFICATION-TYPE
OBJECTS { docsDevEvLevel,
docsDevEvId,
docsDevEvText,
docsIfDocsisBaseCapability,
ifPhysAddress }
STATUS current
DESCRIPTION
"This is an internal software error. The SVCFLO task
detected an error when trying to backup a Service Flow TLV for
CMTS Redundancy. This TLV is not replicated to the peer CMTS,
and could cause this modem to de-register on a CMTS switchover."
::= { rdnEvtNotifications 2473925895 }
rdnEvtSvcfloSidInsertFailure NOTIFICATION-TYPE
OBJECTS { docsDevEvLevel,
docsDevEvId,
docsDevEvText,
docsIfDocsisBaseCapability,
ifPhysAddress }
STATUS current
DESCRIPTION
"This is an internal software error. The SVCFLO task
was unable to store the cable modems Service Id (SID)."
::= { rdnEvtNotifications 2473925899 }
rdnEvtUbshaCollectionRspMallocError NOTIFICATION-TYPE
OBJECTS { docsDevEvLevel,
docsDevEvId,
docsDevEvText,
docsIfDocsisBaseCapability,
ifPhysAddress }
STATUS current
DESCRIPTION
"This is an internal software error. Failed to allocate memory during
upstream channel sampling response."
::= { rdnEvtNotifications 2473927699 }
rdnEvtUbshaTaskSuspended NOTIFICATION-TYPE
OBJECTS { docsDevEvLevel,
docsDevEvId,
docsDevEvText,
docsIfDocsisBaseCapability,
ifPhysAddress }
STATUS current
DESCRIPTION
"This is an internal software error. The Upstream Bandwidth
Scheduler(UBS) task suspended itself. Reset CMTS to clear the
error."
::= { rdnEvtNotifications 2473927709 }
END