1673 lines
60 KiB
Plaintext
1673 lines
60 KiB
Plaintext
IEEE8021-MSTP-MIB DEFINITIONS ::= BEGIN
|
|
|
|
-- =============================================================
|
|
-- MIB for IEEE 802.1Q Multiple Spanning Tree Bridge Devices
|
|
-- =============================================================
|
|
|
|
IMPORTS
|
|
MODULE-IDENTITY, OBJECT-TYPE, Integer32, Counter64,
|
|
Unsigned32, TimeTicks
|
|
FROM SNMPv2-SMI
|
|
TruthValue, RowStatus
|
|
FROM SNMPv2-TC
|
|
ieee802dot1mibs, IEEE8021PbbComponentIdentifier,
|
|
IEEE8021BridgePortNumber, IEEE8021VlanIndex,
|
|
IEEE8021MstIdentifier
|
|
FROM IEEE8021-TC-MIB
|
|
BridgeId
|
|
FROM BRIDGE-MIB
|
|
SnmpAdminString
|
|
FROM SNMP-FRAMEWORK-MIB
|
|
MODULE-COMPLIANCE, OBJECT-GROUP
|
|
FROM SNMPv2-CONF;
|
|
|
|
ieee8021MstpMib MODULE-IDENTITY
|
|
LAST-UPDATED "201806280000Z" -- June 28, 2018
|
|
ORGANIZATION "IEEE 802.1 Working Group"
|
|
CONTACT-INFO
|
|
" WG-URL: http://www.ieee802.org/1/
|
|
WG-EMail: stds-802-1-L@ieee.org
|
|
|
|
Contact: IEEE 802.1 Working Group Chair
|
|
Postal: C/O IEEE 802.1 Working Group
|
|
IEEE Standards Association
|
|
445 Hoes Lane
|
|
Piscataway
|
|
NJ 08854
|
|
USA
|
|
E-mail: STDS-802-1-L@IEEE.ORG"
|
|
DESCRIPTION
|
|
"The Bridge MIB modules for managing devices that support
|
|
IEEE Std 802.1Q multiple spanning tree groups.
|
|
|
|
Unless otherwise indicated, the references in this MIB
|
|
module are to IEEE Std 802.1Q.
|
|
|
|
Copyright (C) IEEE (2018).
|
|
This version of this MIB module is part of IEEE Std 802.1Q;
|
|
see the draft itself for full legal notices."
|
|
|
|
REVISION "201806280000Z" -- June 28, 2018
|
|
DESCRIPTION
|
|
"Published as part of IEEE Std 802.1Q-2018.
|
|
Cross references updated and corrected."
|
|
|
|
REVISION "201412150000Z" -- December 15, 2014
|
|
|
|
DESCRIPTION
|
|
"Published as part of IEEE Std 802.1Q 2014 revision.
|
|
Cross references updated and corrected.
|
|
Instances of ...value of mstp(2)... changed to
|
|
...value of mstp(3).
|
|
Defval for ieee8021MstpCistPortAdminEdgePort
|
|
changed to false.
|
|
ieee8021MstpVlanV2Table DESCRIPTION updated
|
|
(4094 not 4096).
|
|
Bug fixes to conformance section."
|
|
|
|
REVISION "201208100000Z" -- August 10, 2012
|
|
DESCRIPTION
|
|
"Updated cross references to other clauses, particularly
|
|
Clause 13, as part of IEEE 802.1Q Cor-2."
|
|
|
|
REVISION "201112120000Z" -- December 12, 2011
|
|
DESCRIPTION
|
|
"Deprecated ieee8021MstpFidToMstiTable for an identical
|
|
ieee8021MstpFidToMstiV2Table to add 4095 to the range
|
|
of ieee8021MstpFidToMstiV2Fid and to add 0 and 4095 to
|
|
the range of ieee8021MstpFidToMstiV2MstId for IEEE Std 802.1aq.
|
|
Deprecated ieee8021MstpVlanTable for an identical
|
|
ieee8021MstpVlanV2Table to add 0 & 4095 to the range
|
|
of ieee8021MstpVlanV2MstId for IEEE Std 802.1aq"
|
|
|
|
REVISION "201103230000Z" -- March 23, 2011
|
|
DESCRIPTION
|
|
"Minor edits to contact information, correction to range of
|
|
ieee8021MstpCistMaxHops and addition of fragile Bridge
|
|
as part of 2011 revision of IEEE Std 802.1Q."
|
|
|
|
REVISION "200810150000Z" -- October 15, 2008
|
|
DESCRIPTION
|
|
"Initial version."
|
|
::= { ieee802dot1mibs 6 }
|
|
|
|
ieee8021MstpNotifications OBJECT IDENTIFIER ::= { ieee8021MstpMib 0 }
|
|
ieee8021MstpObjects OBJECT IDENTIFIER ::= { ieee8021MstpMib 1 }
|
|
ieee8021MstpConformance OBJECT IDENTIFIER ::= { ieee8021MstpMib 2 }
|
|
|
|
-- =============================================================
|
|
-- MSTP CIST Table
|
|
-- =============================================================
|
|
|
|
ieee8021MstpCistTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF Ieee8021MstpCistEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The Common and Internal Spanning Tree (CIST) Table. Each row in
|
|
the table represents information regarding a Bridge's Bridge
|
|
Protocol Entity for the CIST.
|
|
|
|
Note that entries will exist in this table only for Bridge
|
|
components for which the corresponding instance of
|
|
ieee8021SpanningTreeVersion (from the IEEE8021-SPANNING-TREE-MIB)
|
|
has a value of mstp(3).
|
|
|
|
This table contains objects corresponding to the following items
|
|
from 12.8.1.1 and 12.8.1.3. Some of those items are provided
|
|
in the IEEE8021-SPANNING-TREE-MIB as noted below.
|
|
|
|
From 12.8.1.1:
|
|
Items a), c), o), p), and q) are defined in this table
|
|
The remaining items are covered in the
|
|
IEEE8021-SPANNING-TREE-MIB:
|
|
b) ieee8021SpanningTreeTimeSinceTopologyChange
|
|
c) ieee8021SpanningTreeTopChanges
|
|
e) ieee8021SpanningTreeDesignatedRoot
|
|
f) ieee8021SpanningTreeRootCost
|
|
g) ieee8021SpanningTreeRootPort
|
|
h) ieee8021SpanningTreeMaxAge
|
|
i) ieee8021SpanningTreeForwardDelay
|
|
j) ieee8021SpanningTreeBridgeMaxAge
|
|
k) ieee8021SpanningTreeBridgeHelloTime
|
|
l) ieee8021SpanningTreeBridgeForwardDelay
|
|
m) ieee8021SpanningTreeHoldTime
|
|
n) ieee8021SpanningTreeVersion
|
|
From 12.8.1.3:
|
|
Item g) is defined in this table
|
|
The remaining items are covered in the
|
|
IEEE8021-SPANNING-TREE-MIB:
|
|
a) ieee8021SpanningTreeBridgeMaxAge
|
|
b) ieee8021SpanningTreeBridgeHelloTime
|
|
c) ieee8021SpanningTreeBridgeForwardDelay
|
|
d) ieee8021SpanningTreePriority
|
|
e) ieee8021SpanningTreeVersion
|
|
f) ieee8021RstpStpExtTxHoldCount"
|
|
REFERENCE "12.8.1.1, 12.8.1.3"
|
|
::= { ieee8021MstpObjects 1 }
|
|
|
|
ieee8021MstpCistEntry OBJECT-TYPE
|
|
SYNTAX Ieee8021MstpCistEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A CIST Table entry."
|
|
INDEX { ieee8021MstpCistComponentId }
|
|
::= { ieee8021MstpCistTable 1 }
|
|
|
|
Ieee8021MstpCistEntry ::= SEQUENCE {
|
|
ieee8021MstpCistComponentId IEEE8021PbbComponentIdentifier,
|
|
ieee8021MstpCistBridgeIdentifier BridgeId,
|
|
ieee8021MstpCistTopologyChange TruthValue,
|
|
ieee8021MstpCistRegionalRootIdentifier BridgeId,
|
|
ieee8021MstpCistPathCost Unsigned32,
|
|
ieee8021MstpCistMaxHops Integer32
|
|
}
|
|
|
|
ieee8021MstpCistComponentId OBJECT-TYPE
|
|
SYNTAX IEEE8021PbbComponentIdentifier
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The component identifier is used to distinguish between the
|
|
multiple virtual Bridge instances within a PBB. In simple
|
|
situations where there is only a single component the default
|
|
value is 1."
|
|
::= { ieee8021MstpCistEntry 1 }
|
|
|
|
ieee8021MstpCistBridgeIdentifier OBJECT-TYPE
|
|
SYNTAX BridgeId
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The Bridge Identifier for the CIST."
|
|
REFERENCE "12.8.1.1"
|
|
::= { ieee8021MstpCistEntry 2 }
|
|
|
|
ieee8021MstpCistTopologyChange OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"In an STP Bridge, the value of the Topology Change parameter
|
|
(14.8.1.1.3, item d of IEEE Std 802.1D, 2004 Edition), or in
|
|
an RSTP or MSTP Bridge, asserted if the tcWhile timer for any
|
|
Port for the CIST is non-zero."
|
|
REFERENCE "13.25.9, 14.8.1.1.3:d of IEEE Std 802.1D-2004"
|
|
::= { ieee8021MstpCistEntry 3 }
|
|
|
|
ieee8021MstpCistRegionalRootIdentifier OBJECT-TYPE
|
|
SYNTAX BridgeId
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"In an MSTP Bridge, the CIST Regional Root Identifier parameter,
|
|
i.e., the Bridge Identifier of the current CIST Regional Root."
|
|
REFERENCE "13.16.4, 13.26.3"
|
|
::= { ieee8021MstpCistEntry 4 }
|
|
|
|
ieee8021MstpCistPathCost OBJECT-TYPE
|
|
SYNTAX Unsigned32 (0..2147483647)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"In an MSTP Bridge, the CIST Path Cost parameter, i.e., the CIST
|
|
path cost from the transmitting Bridge to the CIST Regional Root.
|
|
The sum (about 20 possible out of the given range) of multiple
|
|
port path costs. Also, if the 'transmitting Bridge' is
|
|
the 'CIST Regional Root', then this value could be zero."
|
|
REFERENCE "13.9:d, 13.10"
|
|
::= { ieee8021MstpCistEntry 5 }
|
|
|
|
ieee8021MstpCistMaxHops OBJECT-TYPE
|
|
SYNTAX Integer32 (6..40)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"In an MSTP Bridge, the MaxHops parameter.
|
|
|
|
The value of this object MUST be retained across
|
|
reinitializations of the management system."
|
|
REFERENCE "13.26.4"
|
|
::= { ieee8021MstpCistEntry 6 }
|
|
|
|
-- =============================================================
|
|
-- ieee8021MstpTable:
|
|
-- =============================================================
|
|
|
|
ieee8021MstpTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF Ieee8021MstpEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"In an MSTP Bridge, the MSTP Table. Each row in the Table
|
|
represents information regarding a Bridge's Bridge Protocol
|
|
Entity for the specified Spanning Tree instance.
|
|
|
|
Entries in this table MUST be retained across
|
|
reinitializations of the management system.
|
|
|
|
Note that entries can be created in this table only for Bridge
|
|
components for which the corresponding instance of
|
|
ieee8021SpanningTreeVersion (from the IEEE8021-SPANNING-TREE-MIB)
|
|
has a value of mstp(3)."
|
|
REFERENCE "12.8.1.2, 12.8.1.4, 12.12.3.2, 12.12.1"
|
|
::= { ieee8021MstpObjects 2 }
|
|
|
|
ieee8021MstpEntry OBJECT-TYPE
|
|
SYNTAX Ieee8021MstpEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A MSTP Table entry."
|
|
INDEX { ieee8021MstpComponentId, ieee8021MstpId }
|
|
::= { ieee8021MstpTable 1 }
|
|
|
|
Ieee8021MstpEntry ::= SEQUENCE {
|
|
ieee8021MstpComponentId IEEE8021PbbComponentIdentifier,
|
|
ieee8021MstpId IEEE8021MstIdentifier,
|
|
ieee8021MstpBridgeId BridgeId,
|
|
ieee8021MstpTimeSinceTopologyChange TimeTicks,
|
|
ieee8021MstpTopologyChanges Counter64,
|
|
ieee8021MstpTopologyChange TruthValue,
|
|
ieee8021MstpDesignatedRoot BridgeId,
|
|
ieee8021MstpRootPathCost Integer32,
|
|
ieee8021MstpRootPort IEEE8021BridgePortNumber,
|
|
ieee8021MstpBridgePriority Integer32,
|
|
ieee8021MstpVids0 OCTET STRING,
|
|
ieee8021MstpVids1 OCTET STRING,
|
|
ieee8021MstpVids2 OCTET STRING,
|
|
ieee8021MstpVids3 OCTET STRING,
|
|
ieee8021MstpRowStatus RowStatus
|
|
}
|
|
|
|
ieee8021MstpComponentId OBJECT-TYPE
|
|
SYNTAX IEEE8021PbbComponentIdentifier
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The component identifier is used to distinguish between the
|
|
multiple virtual Bridge instances within a PBB. In simple
|
|
situations where there is only a single component the default
|
|
value is 1."
|
|
::= { ieee8021MstpEntry 1 }
|
|
|
|
ieee8021MstpId OBJECT-TYPE
|
|
SYNTAX IEEE8021MstIdentifier
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"In an MSTP Bridge, this parameter is the MSTID, i.e., the
|
|
identifier of a Spanning Tree (or MST) Instance."
|
|
::= { ieee8021MstpEntry 2 }
|
|
|
|
ieee8021MstpBridgeId OBJECT-TYPE
|
|
SYNTAX BridgeId
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"In an MSTP Bridge, the Bridge Identifier for the MSTI."
|
|
REFERENCE "13.26.2"
|
|
::= { ieee8021MstpEntry 3 }
|
|
|
|
ieee8021MstpTimeSinceTopologyChange OBJECT-TYPE
|
|
SYNTAX TimeTicks
|
|
UNITS "centi-seconds"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"In an MSTP Bridge, count in seconds of the time elapsed since
|
|
tcWhile was last non-zero for any Port for the MSTI."
|
|
REFERENCE "13.25.9"
|
|
::= { ieee8021MstpEntry 4 }
|
|
|
|
ieee8021MstpTopologyChanges OBJECT-TYPE
|
|
SYNTAX Counter64
|
|
UNITS "topology changes"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"In an MSTP Bridge, count of the times tcWhile has been
|
|
non-zero for any Port for the MSTI since the Bridge was powered
|
|
on or initialized."
|
|
REFERENCE "13.25.9"
|
|
::= { ieee8021MstpEntry 5 }
|
|
|
|
ieee8021MstpTopologyChange OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"In an MSTP Bridge, the Topology Change parameter value: true(1)
|
|
if tcWhile is non-zero for any Port for the MSTI."
|
|
REFERENCE "13.25.9"
|
|
::= { ieee8021MstpEntry 6 }
|
|
|
|
ieee8021MstpDesignatedRoot OBJECT-TYPE
|
|
SYNTAX BridgeId
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"In an MSTP Bridge, the Designated Root parameter value, i.e., the
|
|
Bridge Identifier of the Root Bridge for the MSTI."
|
|
REFERENCE "13.27.20"
|
|
::= { ieee8021MstpEntry 7 }
|
|
|
|
ieee8021MstpRootPathCost OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"In an MSTP Bridge, the Root Path Cost parameter value, i.e., the
|
|
path cost from the transmitting Bridge to the Root Bridge for
|
|
the MSTI."
|
|
REFERENCE "13.27.20"
|
|
::= { ieee8021MstpEntry 8 }
|
|
|
|
ieee8021MstpRootPort OBJECT-TYPE
|
|
SYNTAX IEEE8021BridgePortNumber
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"In an MSTP Bridge, the Root Port parameter value, i.e., the Root
|
|
Port for the MSTI."
|
|
REFERENCE "13.26.9"
|
|
::= { ieee8021MstpEntry 9 }
|
|
|
|
ieee8021MstpBridgePriority OBJECT-TYPE
|
|
SYNTAX Integer32 (0..61440)
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"In an MSTP Bridge, the Bridge Priority parameter value for the
|
|
MSTI, i.e., the most significant 4 bits of the Bridge Identifier
|
|
for the MSTI."
|
|
REFERENCE "13.26.3"
|
|
::= { ieee8021MstpEntry 10 }
|
|
|
|
ieee8021MstpVids0 OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(128))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object contains the first 1024 bits of the 4096 bit vector
|
|
indicating which VIDs are assigned to this MSTID. The high order
|
|
bit of the first octet corresponds to the first bit of the vector,
|
|
while the low order bit of the last octet corresponds to the last
|
|
bit of this portion of the vector. A bit that is on (equal to 1)
|
|
indicates that the corresponding VID is assigned to this MSTID."
|
|
::= { ieee8021MstpEntry 11 }
|
|
|
|
ieee8021MstpVids1 OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(128))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object contains the second 1024 bits of the 4096 bit vector
|
|
indicating which VIDs are assigned to this MSTID. The high order
|
|
bit of the first octet corresponds to the first bit of this
|
|
portion of the vector, while the low order bit of the last octet
|
|
corresponds to the last bit of this portion of the vector. A bit
|
|
that is on (equal to 1) indicates that the corresponding VID is
|
|
assigned to this MSTID."
|
|
::= { ieee8021MstpEntry 12 }
|
|
|
|
ieee8021MstpVids2 OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(128))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object contains the third 1024 bits of the 4096 bit vector
|
|
indicating which VIDs are assigned to this MSTID. The high order
|
|
bit of the first octet corresponds to the first bit of this
|
|
portion of the vector, while the low order bit of the last octet
|
|
corresponds to the last bit of this portion of the vector. A bit
|
|
that is on (equal to 1) indicates that the corresponding VID is
|
|
assigned to this MSTID."
|
|
::= { ieee8021MstpEntry 13 }
|
|
|
|
ieee8021MstpVids3 OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(128))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object contains the fourth 1024 bits of the 4096 bit vector
|
|
indicating which VIDs are assigned to this MSTID. The high order
|
|
bit of the first octet corresponds to the first bit of this
|
|
portion of the vector, while the low order bit of the last octet
|
|
corresponds to the last bit of this portion of the vector. A bit
|
|
that is on (equal to 1) indicates that the corresponding VID is
|
|
assigned to this MSTID."
|
|
::= { ieee8021MstpEntry 14 }
|
|
|
|
ieee8021MstpRowStatus OBJECT-TYPE
|
|
SYNTAX RowStatus
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The status of the row.
|
|
|
|
Read SNMPv2-TC (RFC2579) for an
|
|
explanation of the possible values this object can take.
|
|
|
|
The writable columns in a row cannot be changed if the row
|
|
is active. All columns must have a valid value before a row
|
|
can be activated."
|
|
::= { ieee8021MstpEntry 15 }
|
|
|
|
-- =============================================================
|
|
-- ieee8021MstpCistPortTable:
|
|
-- =============================================================
|
|
|
|
ieee8021MstpCistPortTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF Ieee8021MstpCistPortEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The CIST Port Table. Each row in the Table represents information
|
|
regarding a specific Port within the Bridge's Bridge Protocol
|
|
Entity, for the CIST.
|
|
|
|
The values of all writable objects in this table MUST be
|
|
retained across reinitializations of the management system.
|
|
|
|
Note that entries will exist in this table only for Bridge
|
|
components for which the corresponding instance of
|
|
ieee8021SpanningTreeVersion (from the IEEE8021-SPANNING-TREE-MIB)
|
|
has a value of mstp(3).
|
|
|
|
This table contains objects corresponding to the following items
|
|
from 12.8.2.1, 12.8.2.3, and 12.8.2.5. Some of those items are
|
|
provided in the IEEE8021-SPANNING-TREE-MIB as noted below.
|
|
|
|
From 12.8.2.1:
|
|
Items a), d), e), and i) through w) are defined in this table
|
|
The remaining items are covered in the
|
|
IEEE8021-SPANNING-TREE-MIB:
|
|
b) ieee8021SpanningTreePortState
|
|
c) ieee8021SpanningTreePortPriority
|
|
d) ieee8021SpanningTreePortPathCost
|
|
f) ieee8021SpanningTreePortDesignatedCost
|
|
g) ieee8021SpanningTreePortDesignatedBridge
|
|
h) ieee8021SpanningTreePortDesignatedPort
|
|
From 12.8.2.3:
|
|
Items a), b), and d) through h) are defined in this table
|
|
(item a is the index)
|
|
The remaining items are covered in the
|
|
IEEE8021-SPANNING-TREE-MIB:
|
|
b) ieee8021SpanningTreePortPathCost,
|
|
c) ieee8021SpanningTreePortPriority
|
|
From 12.8.2.5:
|
|
All items are defined in this table
|
|
Also from 12.8.2.1:
|
|
Items u), v), w), and x) are defined in this table
|
|
Also from 12.8.2.3:
|
|
Items i), j), k), and l) are defined in this table"
|
|
REFERENCE "12.8.2.1, 12.8.2.3, 12.8.2.5"
|
|
::= { ieee8021MstpObjects 3 }
|
|
|
|
ieee8021MstpCistPortEntry OBJECT-TYPE
|
|
SYNTAX Ieee8021MstpCistPortEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A CIST Port Table entry."
|
|
INDEX { ieee8021MstpCistPortComponentId, ieee8021MstpCistPortNum }
|
|
::= { ieee8021MstpCistPortTable 1 }
|
|
|
|
Ieee8021MstpCistPortEntry ::= SEQUENCE {
|
|
ieee8021MstpCistPortComponentId IEEE8021PbbComponentIdentifier,
|
|
ieee8021MstpCistPortNum IEEE8021BridgePortNumber,
|
|
ieee8021MstpCistPortUptime TimeTicks,
|
|
ieee8021MstpCistPortAdminPathCost Integer32,
|
|
ieee8021MstpCistPortDesignatedRoot BridgeId,
|
|
ieee8021MstpCistPortTopologyChangeAck TruthValue,
|
|
ieee8021MstpCistPortHelloTime Integer32,
|
|
ieee8021MstpCistPortAdminEdgePort TruthValue,
|
|
ieee8021MstpCistPortOperEdgePort TruthValue,
|
|
ieee8021MstpCistPortMacEnabled TruthValue,
|
|
ieee8021MstpCistPortMacOperational TruthValue,
|
|
ieee8021MstpCistPortRestrictedRole TruthValue,
|
|
ieee8021MstpCistPortRestrictedTcn TruthValue,
|
|
ieee8021MstpCistPortRole INTEGER,
|
|
ieee8021MstpCistPortDisputed TruthValue,
|
|
ieee8021MstpCistPortCistRegionalRootId BridgeId,
|
|
ieee8021MstpCistPortCistPathCost Unsigned32,
|
|
ieee8021MstpCistPortProtocolMigration TruthValue,
|
|
ieee8021MstpCistPortEnableBPDURx TruthValue,
|
|
ieee8021MstpCistPortEnableBPDUTx TruthValue,
|
|
ieee8021MstpCistPortPseudoRootId BridgeId,
|
|
ieee8021MstpCistPortIsL2Gp TruthValue
|
|
}
|
|
|
|
ieee8021MstpCistPortComponentId OBJECT-TYPE
|
|
SYNTAX IEEE8021PbbComponentIdentifier
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The component identifier is used to distinguish between the
|
|
multiple virtual Bridge instances within a PBB. In simple
|
|
situations where there is only a single component the default
|
|
value is 1."
|
|
::= { ieee8021MstpCistPortEntry 1 }
|
|
|
|
ieee8021MstpCistPortNum OBJECT-TYPE
|
|
SYNTAX IEEE8021BridgePortNumber
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The Port's Port Number parameter value for the CIST, i.e., the
|
|
number of the Bridge Port for the CIST."
|
|
::= { ieee8021MstpCistPortEntry 2 }
|
|
|
|
ieee8021MstpCistPortUptime OBJECT-TYPE
|
|
SYNTAX TimeTicks
|
|
UNITS "centi-seconds"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The Port's Uptime parameter value for the CIST, i.e., the count
|
|
in seconds of the time elapsed since the Port was last reset or
|
|
initialized (BEGIN, Annex E)."
|
|
::= { ieee8021MstpCistPortEntry 3 }
|
|
|
|
ieee8021MstpCistPortAdminPathCost OBJECT-TYPE
|
|
SYNTAX Integer32 (0..200000000)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The administratively assigned value for the contribution
|
|
of this port to the path cost of paths toward the spanning
|
|
tree root.
|
|
|
|
Writing a value of '0' assigns the automatically calculated
|
|
default Path Cost value to the port. If the default Path
|
|
Cost is being used, this object returns '0' when read.
|
|
|
|
This complements the object ieee8021MstpCistPortCistPathCost,
|
|
which returns the operational value of the port path cost.
|
|
|
|
The value of this object MUST be retained across
|
|
reinitializations of the management system."
|
|
REFERENCE "13.27.25, 17.13.11 of IEEE Std 802.1D"
|
|
::= { ieee8021MstpCistPortEntry 4 }
|
|
|
|
ieee8021MstpCistPortDesignatedRoot OBJECT-TYPE
|
|
SYNTAX BridgeId
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The CIST Regional Root Identifier component of the Port's port
|
|
priority vector, as defined in 13.10, for the CIST."
|
|
REFERENCE "13.27.47"
|
|
::= { ieee8021MstpCistPortEntry 5 }
|
|
|
|
ieee8021MstpCistPortTopologyChangeAck OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The Port's Topology Change Acknowledge parameter value.
|
|
True(1) if a Configuration Message with a topology change
|
|
acknowledge flag set is to be transmitted. "
|
|
REFERENCE "13.27.72, 17.19.41 of IEEE Std 802.1D"
|
|
::= { ieee8021MstpCistPortEntry 6 }
|
|
|
|
ieee8021MstpCistPortHelloTime OBJECT-TYPE
|
|
SYNTAX Integer32 (100..1000)
|
|
UNITS "centi-seconds"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The Port's Hello Time timer parameter value, for the CIST.
|
|
In centi-seconds"
|
|
REFERENCE "13.27.48"
|
|
::= { ieee8021MstpCistPortEntry 7 }
|
|
|
|
ieee8021MstpCistPortAdminEdgePort OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"In a Bridge that supports the identification of edge ports, the
|
|
Port's Admin Edge Port parameter value, for the CIST."
|
|
REFERENCE "13.27.1"
|
|
DEFVAL { false }
|
|
::= { ieee8021MstpCistPortEntry 8 }
|
|
|
|
ieee8021MstpCistPortOperEdgePort OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"In a Bridge that supports the identification of edge ports, the
|
|
Port's operational Edge Port parameter value, for the CIST.
|
|
True(1) if it is an Oper Edge Port."
|
|
REFERENCE "13.27.44"
|
|
::= { ieee8021MstpCistPortEntry 9 }
|
|
|
|
ieee8021MstpCistPortMacEnabled OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"In a Bridge that supports the MAC Enabled parameter, the current
|
|
state of the MAC Enabled parameter.
|
|
True(1) indicates that adminstratively the MAC is set as if it
|
|
was connected to a point-to-point LAN."
|
|
REFERENCE "12.8.2.1.3 p)"
|
|
::= { ieee8021MstpCistPortEntry 10 }
|
|
|
|
ieee8021MstpCistPortMacOperational OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"In a Bridge that supports the MAC Operational parameter, the
|
|
current state of the MAC Operational parameter.
|
|
True(1) indicates the MAC is operational."
|
|
REFERENCE "12.8.2.1.3 q)"
|
|
::= { ieee8021MstpCistPortEntry 11 }
|
|
|
|
ieee8021MstpCistPortRestrictedRole OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The current state of the restrictedRole parameter for the Port.
|
|
True(1) causes the Port not to be selected as Root Port for the
|
|
CIST or any MSTI. "
|
|
REFERENCE "13.27.64"
|
|
::= { ieee8021MstpCistPortEntry 12 }
|
|
|
|
ieee8021MstpCistPortRestrictedTcn OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The current state of the restrictedTcn parameter for the Port.
|
|
True(1) causes the Port not to propagate topology changes to
|
|
other Ports."
|
|
REFERENCE "13.27.65"
|
|
::= { ieee8021MstpCistPortEntry 13 }
|
|
|
|
ieee8021MstpCistPortRole OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
root(1),
|
|
alternate(2),
|
|
designated(3),
|
|
backup(4)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The current Port Role for the Port (i.e., Root, Alternate,
|
|
Designated, or Backup), for the CIST."
|
|
REFERENCE "12.8.2.1.3 v)"
|
|
::= { ieee8021MstpCistPortEntry 14 }
|
|
|
|
ieee8021MstpCistPortDisputed OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The current value of the disputed variable for the CIST for
|
|
the Port. A value of true(1) indicates that the disputed
|
|
variable is set. A value of false(2) indicates that the
|
|
agreed variable is cleared."
|
|
REFERENCE "13.27.22"
|
|
::= { ieee8021MstpCistPortEntry 15 }
|
|
|
|
ieee8021MstpCistPortCistRegionalRootId OBJECT-TYPE
|
|
SYNTAX BridgeId
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"In an MSTP Bridge, the CIST Regional Root Identifier, i.e., the
|
|
Bridge Identifier of the current CIST Regional Root, for the CIST."
|
|
REFERENCE "13.9:c, 13.10, 13.27.47"
|
|
::= { ieee8021MstpCistPortEntry 16 }
|
|
|
|
ieee8021MstpCistPortCistPathCost OBJECT-TYPE
|
|
SYNTAX Unsigned32 (0..2147483647)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"In an MSTP Bridge, the Port's Port Path Cost
|
|
parameter value for the CIST."
|
|
REFERENCE "13.27.25, 17.13.11 of IEEE Std 802.1D"
|
|
::= { ieee8021MstpCistPortEntry 17 }
|
|
|
|
ieee8021MstpCistPortProtocolMigration OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"In an MSTP Bridge, the current value of the mcheck variable for
|
|
the Port. A value of true(1) forces the state machine to
|
|
perform functions as per 13.27.38."
|
|
REFERENCE "13.27.38"
|
|
::= { ieee8021MstpCistPortEntry 18 }
|
|
|
|
ieee8021MstpCistPortEnableBPDURx OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"In an MSTP Bridge, the enableBPDUrx parameter value. A value
|
|
of false(2) indicates that BPDUs are ignored."
|
|
REFERENCE "13.27.38"
|
|
DEFVAL { true }
|
|
::= { ieee8021MstpCistPortEntry 19 }
|
|
|
|
ieee8021MstpCistPortEnableBPDUTx OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"In an MSTP Bridge, the enableBPDUtx parameter value. A value
|
|
of false(2) indicates that BPDUs are not transmitted."
|
|
REFERENCE "13.27.24"
|
|
DEFVAL { true }
|
|
::= { ieee8021MstpCistPortEntry 20 }
|
|
|
|
ieee8021MstpCistPortPseudoRootId OBJECT-TYPE
|
|
SYNTAX BridgeId
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"In an MSTP Bridge, the pseudoRootId parameter value."
|
|
REFERENCE "13.27.51"
|
|
::= { ieee8021MstpCistPortEntry 21 }
|
|
|
|
ieee8021MstpCistPortIsL2Gp OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"In an MSTP Bridge, the isL2gp parameter value. A value of
|
|
true(1) indicates this is an L2GP port."
|
|
REFERENCE "13.27.26"
|
|
DEFVAL { false }
|
|
::= { ieee8021MstpCistPortEntry 22 }
|
|
|
|
-- =============================================================
|
|
-- ieee8021MstpPortTable:
|
|
-- =============================================================
|
|
|
|
ieee8021MstpPortTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF Ieee8021MstpPortEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The MSTP Port Table. Each row in the Table represents information
|
|
regarding a specific Port within the Bridge's Bridge Protocol
|
|
Entity, for a given MSTI.
|
|
|
|
The values of all writable objects in this table MUST be
|
|
retained across reinitializations of the management system.
|
|
|
|
Note that entries will exist in this table only for Bridge
|
|
components for which the corresponding instance of
|
|
ieee8021SpanningTreeVersion (from the IEEE8021-SPANNING-TREE-MIB)
|
|
has a value of mstp(3)."
|
|
REFERENCE "12.8.2.2, 12.8.2.4"
|
|
::= { ieee8021MstpObjects 4 }
|
|
|
|
ieee8021MstpPortEntry OBJECT-TYPE
|
|
SYNTAX Ieee8021MstpPortEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A MSTP Port Table entry."
|
|
INDEX { ieee8021MstpPortComponentId,
|
|
ieee8021MstpPortMstId,
|
|
ieee8021MstpPortNum }
|
|
::= { ieee8021MstpPortTable 1 }
|
|
|
|
Ieee8021MstpPortEntry ::= SEQUENCE {
|
|
ieee8021MstpPortComponentId IEEE8021PbbComponentIdentifier,
|
|
ieee8021MstpPortMstId IEEE8021MstIdentifier,
|
|
ieee8021MstpPortNum IEEE8021BridgePortNumber,
|
|
ieee8021MstpPortUptime TimeTicks,
|
|
ieee8021MstpPortState INTEGER,
|
|
ieee8021MstpPortPriority Integer32,
|
|
ieee8021MstpPortPathCost Integer32,
|
|
ieee8021MstpPortDesignatedRoot BridgeId,
|
|
ieee8021MstpPortDesignatedCost Integer32,
|
|
ieee8021MstpPortDesignatedBridge BridgeId,
|
|
ieee8021MstpPortDesignatedPort IEEE8021BridgePortNumber,
|
|
ieee8021MstpPortRole INTEGER,
|
|
ieee8021MstpPortDisputed TruthValue,
|
|
ieee8021MstpPortAdminPathCost Integer32
|
|
}
|
|
|
|
ieee8021MstpPortComponentId OBJECT-TYPE
|
|
SYNTAX IEEE8021PbbComponentIdentifier
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The component identifier is used to distinguish between the
|
|
multiple virtual Bridge instances within a PBB. In simple
|
|
situations where there is only a single component the default
|
|
value is 1."
|
|
::= { ieee8021MstpPortEntry 1 }
|
|
|
|
ieee8021MstpPortMstId OBJECT-TYPE
|
|
SYNTAX IEEE8021MstIdentifier
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"In an MSTP Bridge, this parameter is the MSTID, i.e., the
|
|
identifier of a Spanning Tree (or MST) Instance."
|
|
::= { ieee8021MstpPortEntry 2 }
|
|
|
|
ieee8021MstpPortNum OBJECT-TYPE
|
|
SYNTAX IEEE8021BridgePortNumber
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"In an MSTP Bridge, the Port's Port Number parameter value for
|
|
the MSTI, i.e., the number of the Bridge Port for the MSTI."
|
|
::= { ieee8021MstpPortEntry 3 }
|
|
|
|
ieee8021MstpPortUptime OBJECT-TYPE
|
|
SYNTAX TimeTicks
|
|
UNITS "centi-seconds"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"In an MSTP Bridge, the Port's Uptime parameter value for the
|
|
MSTI, i.e., the count in seconds of the time elapsed since the
|
|
Port was last reset or initialized (BEGIN, Annex E)."
|
|
::= { ieee8021MstpPortEntry 4 }
|
|
|
|
ieee8021MstpPortState OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled(1),
|
|
listening(2),
|
|
learning(3),
|
|
forwarding(4),
|
|
blocking(5)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"In an MSTP Bridge, the current state of the Port (i.e., Disabled,
|
|
Listening, Learning, Forwarding, or Blocking), for the MSTI."
|
|
REFERENCE "13.38"
|
|
::= { ieee8021MstpPortEntry 5 }
|
|
|
|
ieee8021MstpPortPriority OBJECT-TYPE
|
|
SYNTAX Integer32 (0..240)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"In an MSTP Bridge, the Port's Port Priority parameter value for
|
|
the MSTI, i.e., the priority field for the Port Identifier for the
|
|
Port for the MSTI."
|
|
REFERENCE "13.27.47"
|
|
::= { ieee8021MstpPortEntry 6 }
|
|
|
|
ieee8021MstpPortPathCost OBJECT-TYPE
|
|
SYNTAX Integer32 (1..200000000)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"In an MSTP Bridge, the Port's Port Path Cost parameter value for
|
|
the MSTI."
|
|
REFERENCE "13.27.33"
|
|
::= { ieee8021MstpPortEntry 7 }
|
|
|
|
ieee8021MstpPortDesignatedRoot OBJECT-TYPE
|
|
SYNTAX BridgeId
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"In an MSTP Bridge, the Regional Root Identifier component of the
|
|
Port's MSTI port priority vector, as defined in 13.11, for the MSTI."
|
|
REFERENCE "13.27.47"
|
|
::= { ieee8021MstpPortEntry 8 }
|
|
|
|
ieee8021MstpPortDesignatedCost OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"In an MSTP Bridge, the Internal Root Path Cost component of the
|
|
Port's MSTI port priority vector, as defined in 13.11, for the MSTI."
|
|
REFERENCE "13.27.47"
|
|
::= { ieee8021MstpPortEntry 9 }
|
|
|
|
ieee8021MstpPortDesignatedBridge OBJECT-TYPE
|
|
SYNTAX BridgeId
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"In an MSTP Bridge, the Designated Bridge Identifier component of
|
|
the Port's MSTI port priority vector, as defined in 13.11, for
|
|
the MSTI."
|
|
REFERENCE "13.27.47"
|
|
::= { ieee8021MstpPortEntry 10 }
|
|
|
|
ieee8021MstpPortDesignatedPort OBJECT-TYPE
|
|
SYNTAX IEEE8021BridgePortNumber
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"In an MSTP Bridge, the Designated Port Identifier component of the
|
|
Port's MSTI port priority vector, as defined in 13.11, for the MSTI."
|
|
REFERENCE "13.27.47"
|
|
::= { ieee8021MstpPortEntry 11 }
|
|
|
|
ieee8021MstpPortRole OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
root(1),
|
|
alternate(2),
|
|
designated(3),
|
|
backup(4)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"In an MSTP Bridge, the current Port Role for the Port (i.e., Root,
|
|
Alternate, Designated, or Backup), for the MSTI."
|
|
::= { ieee8021MstpPortEntry 12 }
|
|
|
|
ieee8021MstpPortDisputed OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"In an MSTP Bridge, the current value of the disputed variable for
|
|
the MSTI for the Port."
|
|
REFERENCE "13.27.22"
|
|
::= { ieee8021MstpPortEntry 13 }
|
|
|
|
|
|
ieee8021MstpPortAdminPathCost OBJECT-TYPE
|
|
SYNTAX Integer32 (1..200000000)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"In an MSTP Bridge, the administrative value of the Port's
|
|
Port Path Cost parameter value for the MSTI.
|
|
|
|
Writing a value of '0' assigns the automatically calculated
|
|
default Path Cost value to the Port. If the default Path
|
|
Cost is being used, this object returns '0' when read.
|
|
|
|
This complements the object ieee8021MstpPortPathCost,
|
|
which returns the operational value of the path cost.
|
|
|
|
The value of this object MUST be retained across
|
|
reinitializations of the management system."
|
|
REFERENCE "13.27.33"
|
|
::= { ieee8021MstpPortEntry 14 }
|
|
|
|
-- =============================================================
|
|
-- ieee8021MstpFidToMstiTable deprecated
|
|
-- see ieee8021MstpFidToMstiV2Table below
|
|
-- =============================================================
|
|
|
|
ieee8021MstpFidToMstiTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF Ieee8021MstpFidToMstiEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"In an MSTP Bridge, the fixed-length FID to MSTID Allocation Table
|
|
entry. Each entry in the Table corresponds to a FID, and the value
|
|
of the entry specifies the MSTID of the spanning tree to which the
|
|
set of VLANs supported by that FID are assigned. A value of zero
|
|
in an entry specifies that the set of VLANs supported by that FID
|
|
are assigned to the CST.
|
|
|
|
The values of all writable objects in this table MUST be
|
|
retained across reinitializations of the management system.
|
|
|
|
Note that entries will exist in this table only for Bridge
|
|
components for which the corresponding instance of
|
|
ieee8021SpanningTreeVersion (from the IEEE8021-SPANNING-TREE-MIB)
|
|
has a value of mstp(3)."
|
|
REFERENCE "12.12.2"
|
|
::= { ieee8021MstpObjects 5 }
|
|
|
|
ieee8021MstpFidToMstiEntry OBJECT-TYPE
|
|
SYNTAX Ieee8021MstpFidToMstiEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"In an MSTP Bridge, a FID to MSTID Allocation Table entry."
|
|
INDEX { ieee8021MstpFidToMstiComponentId, ieee8021MstpFidToMstiFid }
|
|
::= { ieee8021MstpFidToMstiTable 1 }
|
|
|
|
Ieee8021MstpFidToMstiEntry ::= SEQUENCE {
|
|
ieee8021MstpFidToMstiComponentId IEEE8021PbbComponentIdentifier,
|
|
ieee8021MstpFidToMstiFid Unsigned32,
|
|
ieee8021MstpFidToMstiMstId IEEE8021MstIdentifier
|
|
}
|
|
|
|
ieee8021MstpFidToMstiComponentId OBJECT-TYPE
|
|
SYNTAX IEEE8021PbbComponentIdentifier
|
|
MAX-ACCESS not-accessible
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"The component identifier is used to distinguish between the
|
|
multiple virtual Bridge instances within a PBB. In simple
|
|
situations where there is only a single component the default
|
|
value is 1."
|
|
::= { ieee8021MstpFidToMstiEntry 1 }
|
|
|
|
ieee8021MstpFidToMstiFid OBJECT-TYPE
|
|
SYNTAX Unsigned32 (1..4094)
|
|
MAX-ACCESS not-accessible
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"In an MSTP Bridge, the FID of the entry in the FID to MSTID
|
|
Allocation Table."
|
|
::= { ieee8021MstpFidToMstiEntry 2 }
|
|
|
|
ieee8021MstpFidToMstiMstId OBJECT-TYPE
|
|
SYNTAX IEEE8021MstIdentifier
|
|
MAX-ACCESS read-write
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"In an MSTP Bridge, the MSTID to which the FID (of the entry in
|
|
the FID to MSTID Allocation Table) is to be allocated."
|
|
::= { ieee8021MstpFidToMstiEntry 3 }
|
|
|
|
-- =============================================================
|
|
-- ieee8021MstpFidToMstiV2Table
|
|
-- =============================================================
|
|
|
|
ieee8021MstpFidToMstiV2Table OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF Ieee8021MstpFidToMstiV2Entry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"In an MSTP Bridge, the fixed-length FID to MSTID Allocation Table
|
|
entry. Each entry in the Table corresponds to a FID, and the value
|
|
of the entry specifies the MSTID of the spanning tree to which the
|
|
set of VLANs supported by that FID are assigned. A value of zero
|
|
in an entry specifies that the set of VLANs supported by that FID
|
|
are assigned to the CST.
|
|
|
|
The values of all writable objects in this table MUST be
|
|
retained across reinitializations of the management system.
|
|
|
|
Note that entries will exist in this table only for Bridge
|
|
components for which the corresponding instance of
|
|
ieee8021SpanningTreeVersion (from the IEEE8021-SPANNING-TREE-MIB)
|
|
has a value of mstp(3)."
|
|
REFERENCE "12.12.2"
|
|
::= { ieee8021MstpObjects 9 }
|
|
|
|
ieee8021MstpFidToMstiV2Entry OBJECT-TYPE
|
|
SYNTAX Ieee8021MstpFidToMstiV2Entry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"In an MSTP Bridge, a FID to MSTID Allocation Table entry."
|
|
INDEX { ieee8021MstpFidToMstiV2ComponentId, ieee8021MstpFidToMstiV2Fid }
|
|
::= { ieee8021MstpFidToMstiV2Table 1 }
|
|
|
|
Ieee8021MstpFidToMstiV2Entry ::= SEQUENCE {
|
|
ieee8021MstpFidToMstiV2ComponentId IEEE8021PbbComponentIdentifier,
|
|
ieee8021MstpFidToMstiV2Fid Unsigned32,
|
|
ieee8021MstpFidToMstiV2MstId Unsigned32
|
|
}
|
|
|
|
ieee8021MstpFidToMstiV2ComponentId OBJECT-TYPE
|
|
SYNTAX IEEE8021PbbComponentIdentifier
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The component identifier is used to distinguish between the
|
|
multiple virtual Bridge instances within a PBB. In simple
|
|
situations where there is only a single component the default
|
|
value is 1."
|
|
::= { ieee8021MstpFidToMstiV2Entry 1 }
|
|
|
|
ieee8021MstpFidToMstiV2Fid OBJECT-TYPE
|
|
SYNTAX Unsigned32 (1..4095)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"In an MSTP Bridge, the FID of the entry in the FID to MSTID
|
|
Allocation Table."
|
|
::= { ieee8021MstpFidToMstiV2Entry 2 }
|
|
|
|
ieee8021MstpFidToMstiV2MstId OBJECT-TYPE
|
|
SYNTAX Unsigned32 (0..4095)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"In an MSTP Bridge, the MSTID to which the FID (of the entry in
|
|
the FID to MSTID Allocation Table) is to be allocated.
|
|
In an SPT Bridge, the value 4095 is used to indicate unused
|
|
(non-filtering) FIDs."
|
|
::= { ieee8021MstpFidToMstiV2Entry 3 }
|
|
|
|
-- =============================================================
|
|
-- ieee8021MstpVlanTable deprecated
|
|
-- see ieee8021MstpVlanV2Table below
|
|
-- =============================================================
|
|
|
|
ieee8021MstpVlanTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF Ieee8021MstpVlanEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"In an MSTP Bridge, the fixed-length (4094 elements), read-only,
|
|
MST Configuration Table. Its elements are derived from other
|
|
configuration information held by the Bridge; specifically, the
|
|
current state of the VID to FID Allocation Table (8.8.8,
|
|
12.10.1),and the FID to MSTID Allocation Table (8.9.3, 12.12.2).
|
|
Hence, changes made to either of these Tables can in turn affect
|
|
the contents of the MST Configuration Table, and also affect the
|
|
value of the digest element of the MST Configuration Identifier.
|
|
|
|
The values of all writable objects in this table MUST be
|
|
retained across reinitializations of the management system.
|
|
|
|
Note that entries will exist in this table only for Bridge
|
|
components for which the corresponding instance of
|
|
ieee8021SpanningTreeVersion (from the IEEE8021-SPANNING-TREE-MIB)
|
|
has a value of mstp(3)."
|
|
REFERENCE "12.12.3.1"
|
|
::= { ieee8021MstpObjects 6 }
|
|
|
|
ieee8021MstpVlanEntry OBJECT-TYPE
|
|
SYNTAX Ieee8021MstpVlanEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"In an MSTP Bridge, a MST Configuration Table entry."
|
|
INDEX { ieee8021MstpVlanComponentId, ieee8021MstpVlanId }
|
|
::= { ieee8021MstpVlanTable 1 }
|
|
|
|
Ieee8021MstpVlanEntry ::= SEQUENCE {
|
|
ieee8021MstpVlanComponentId IEEE8021PbbComponentIdentifier,
|
|
ieee8021MstpVlanId IEEE8021VlanIndex,
|
|
ieee8021MstpVlanMstId IEEE8021MstIdentifier
|
|
}
|
|
|
|
ieee8021MstpVlanComponentId OBJECT-TYPE
|
|
SYNTAX IEEE8021PbbComponentIdentifier
|
|
MAX-ACCESS not-accessible
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"The component identifier is used to distinguish between the
|
|
multiple virtual Bridge instances within a PBB. In simple
|
|
situations where there is only a single component the default
|
|
value is 1."
|
|
::= { ieee8021MstpVlanEntry 1 }
|
|
|
|
ieee8021MstpVlanId OBJECT-TYPE
|
|
SYNTAX IEEE8021VlanIndex
|
|
MAX-ACCESS not-accessible
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"In an MSTP Bridge, the VID of the entry in the MST
|
|
Configuration Table."
|
|
::= { ieee8021MstpVlanEntry 2 }
|
|
|
|
ieee8021MstpVlanMstId OBJECT-TYPE
|
|
SYNTAX IEEE8021MstIdentifier
|
|
MAX-ACCESS read-only
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"In an MSTP Bridge, the MSTID value corresponding to the VID
|
|
of the entry in the MST Configuration Table."
|
|
::= { ieee8021MstpVlanEntry 3 }
|
|
|
|
-- =============================================================
|
|
-- ieee8021MstpVlanV2Table
|
|
-- =============================================================
|
|
|
|
ieee8021MstpVlanV2Table OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF Ieee8021MstpVlanV2Entry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"In an MSTP Bridge, the fixed-length (4094 elements), read-only,
|
|
MST Configuration Table. Its elements are derived from other
|
|
configuration information held by the Bridge; specifically, the
|
|
current state of the VID to FID Allocation Table (8.8.8,
|
|
12.10.1),and the FID to MSTID Allocation Table (8.9.3, 12.12.2).
|
|
Hence, changes made to either of these Tables can in turn affect
|
|
the contents of the MST Configuration Table, and also affect the
|
|
value of the digest element of the MST Configuration Identifier.
|
|
|
|
The values of all writable objects in this table MUST be
|
|
retained across reinitializations of the management system.
|
|
|
|
Note that entries will exist in this table only for Bridge
|
|
components for which the corresponding instance of
|
|
ieee8021SpanningTreeVersion (from the IEEE8021-SPANNING-TREE-MIB)
|
|
has a value of mstp(3)."
|
|
REFERENCE "12.12.3.1"
|
|
::= { ieee8021MstpObjects 10 }
|
|
|
|
ieee8021MstpVlanV2Entry OBJECT-TYPE
|
|
SYNTAX Ieee8021MstpVlanV2Entry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"In an MSTP Bridge, a MST Configuration Table entry."
|
|
INDEX { ieee8021MstpVlanV2ComponentId, ieee8021MstpVlanV2Id }
|
|
::= { ieee8021MstpVlanV2Table 1 }
|
|
|
|
Ieee8021MstpVlanV2Entry ::= SEQUENCE {
|
|
ieee8021MstpVlanV2ComponentId IEEE8021PbbComponentIdentifier,
|
|
ieee8021MstpVlanV2Id IEEE8021VlanIndex,
|
|
ieee8021MstpVlanV2MstId Unsigned32
|
|
}
|
|
|
|
ieee8021MstpVlanV2ComponentId OBJECT-TYPE
|
|
SYNTAX IEEE8021PbbComponentIdentifier
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The component identifier is used to distinguish between the
|
|
multiple virtual Bridge instances within a PBB. In simple
|
|
situations where there is only a single component the default
|
|
value is 1."
|
|
::= { ieee8021MstpVlanV2Entry 1 }
|
|
|
|
ieee8021MstpVlanV2Id OBJECT-TYPE
|
|
SYNTAX IEEE8021VlanIndex
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"In an MSTP Bridge, the VID of the entry in the MST
|
|
Configuration Table."
|
|
::= { ieee8021MstpVlanV2Entry 2 }
|
|
|
|
ieee8021MstpVlanV2MstId OBJECT-TYPE
|
|
SYNTAX Unsigned32 (0..4095)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"In an MSTP Bridge, the MSTID value corresponding to the VID
|
|
of the entry in the MST Configuration Table.
|
|
In an SPT Bridge, a value of 4095 is used to indicate
|
|
SPVIDs."
|
|
::= { ieee8021MstpVlanV2Entry 3 }
|
|
|
|
-- =============================================================
|
|
-- MST Configuration Identifier Table
|
|
-- =============================================================
|
|
|
|
ieee8021MstpConfigIdTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF Ieee8021MstpConfigIdEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A table containing the MST Configuration Identifier for each
|
|
virtual Bridge. In simple situations where there is only
|
|
a single component, there will only be a single entry in
|
|
this table (i.e., only a single MST Configuration Identifier).
|
|
|
|
The values of all writable objects in this table MUST be
|
|
retained across reinitializations of the management system.
|
|
|
|
Note that entries will exist in this table only for Bridge
|
|
components for which the corresponding instance of
|
|
ieee8021SpanningTreeVersion (from the IEEE8021-SPANNING-TREE-MIB)
|
|
has a value of mstp(3)."
|
|
REFERENCE "12.12.3.3, 12.12.3.4"
|
|
::= { ieee8021MstpObjects 7 }
|
|
|
|
ieee8021MstpConfigIdEntry OBJECT-TYPE
|
|
SYNTAX Ieee8021MstpConfigIdEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry contining the MST Configuration Identifier of a Bridge."
|
|
INDEX { ieee8021MstpConfigIdComponentId }
|
|
::= { ieee8021MstpConfigIdTable 1 }
|
|
|
|
Ieee8021MstpConfigIdEntry ::= SEQUENCE {
|
|
ieee8021MstpConfigIdComponentId IEEE8021PbbComponentIdentifier,
|
|
ieee8021MstpConfigIdFormatSelector Integer32,
|
|
ieee8021MstpConfigurationName SnmpAdminString,
|
|
ieee8021MstpRevisionLevel Unsigned32,
|
|
ieee8021MstpConfigurationDigest OCTET STRING
|
|
}
|
|
|
|
ieee8021MstpConfigIdComponentId OBJECT-TYPE
|
|
SYNTAX IEEE8021PbbComponentIdentifier
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The component identifier is used to distinguish between the
|
|
multiple virtual Bridge instances within a PBB. In simple
|
|
situations where there is only a single component the default
|
|
value is 1."
|
|
::= { ieee8021MstpConfigIdEntry 1 }
|
|
|
|
ieee8021MstpConfigIdFormatSelector OBJECT-TYPE
|
|
SYNTAX Integer32 (0..0)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"In an MSTP Bridge, the Configuration Identifier Format Selector
|
|
in use by the Bridge, in the MST Configuration Identifier. This
|
|
has a value of 0 to indicate the format specified in IEEE Std 802.1Q."
|
|
REFERENCE "13.8:1"
|
|
::= { ieee8021MstpConfigIdEntry 2 }
|
|
|
|
ieee8021MstpConfigurationName OBJECT-TYPE
|
|
SYNTAX SnmpAdminString (SIZE(32))
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"In an MSTP Bridge, the Configuration Name in the MST
|
|
Configuration Identifier."
|
|
REFERENCE "13.8:2"
|
|
::= { ieee8021MstpConfigIdEntry 3 }
|
|
|
|
ieee8021MstpRevisionLevel OBJECT-TYPE
|
|
SYNTAX Unsigned32 (0..65535)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"In an MSTP Bridge, the Revision Level in the MST
|
|
Configuration Identifier."
|
|
REFERENCE "13.8:3"
|
|
::= { ieee8021MstpConfigIdEntry 4 }
|
|
|
|
ieee8021MstpConfigurationDigest OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(16))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"In an MSTP Bridge, the Configuration Digest in the MST
|
|
Configuration Identifier."
|
|
REFERENCE "13.8:4"
|
|
::= { ieee8021MstpConfigIdEntry 5 }
|
|
|
|
|
|
-- =============================================================
|
|
-- Ieee8021MstpCistPortExtensionTable:
|
|
-- =============================================================
|
|
|
|
ieee8021MstpCistPortExtensionTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF Ieee8021MstpCistPortExtensionEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The CIST Port Extensions Table. Each row in the Table represents information
|
|
regarding a specific Port within the Bridge's Bridge Protocol
|
|
Entity, for the CIST."
|
|
REFERENCE "12.8.2"
|
|
::= { ieee8021MstpObjects 8 }
|
|
|
|
ieee8021MstpCistPortExtensionEntry OBJECT-TYPE
|
|
SYNTAX Ieee8021MstpCistPortExtensionEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A list of additional objects containing information
|
|
maintained by every port about the CIST
|
|
state for that port."
|
|
AUGMENTS { ieee8021MstpCistPortEntry}
|
|
::= { ieee8021MstpCistPortExtensionTable 1 }
|
|
|
|
Ieee8021MstpCistPortExtensionEntry ::=
|
|
SEQUENCE {
|
|
ieee8021MstpCistPortAutoEdgePort
|
|
TruthValue,
|
|
ieee8021MstpCistPortAutoIsolatePort
|
|
TruthValue
|
|
}
|
|
|
|
ieee8021MstpCistPortAutoEdgePort OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The administrative value of the Auto Edge Port parameter.
|
|
A value of true(1) indicates if the Bridge detection state
|
|
machine (BDM, 13.31) is to detect other Bridges
|
|
attached to the LAN, and set
|
|
ieee8021SpanningTreeRstpPortOperEdgePort automatically.
|
|
The default value is true(1)
|
|
|
|
This is optional and provided only by implementations
|
|
that support the automatic identification of edge ports.
|
|
|
|
The value of this object MUST be retained across
|
|
reinitializations of the management system."
|
|
REFERENCE "12.8.2.1.3 )"
|
|
::= { ieee8021MstpCistPortExtensionEntry 1 }
|
|
|
|
ieee8021MstpCistPortAutoIsolatePort OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The operational value of the Isolate Port parameter.
|
|
|
|
A value of true(1) indicates a Designated Port will
|
|
transition to discarding if both
|
|
ieee8021SpanningTreeRstpPortAdminEdgePort and
|
|
ieee8021SpanningTreeRstpPortAutoEdgePort are FALSE and
|
|
the other Bridge presumed to be attached to the same
|
|
point-to-point LAN does not transmit periodic BPDUs.
|
|
|
|
This is optional and provided only by implementations
|
|
that support the automatic identification of fragile
|
|
Bridges."
|
|
REFERENCE "12.8.2.1.3"
|
|
::= { ieee8021MstpCistPortExtensionEntry 2 }
|
|
|
|
|
|
-- =============================================================
|
|
-- Conformance Information
|
|
-- =============================================================
|
|
|
|
ieee8021MstpGroups
|
|
OBJECT IDENTIFIER ::= { ieee8021MstpConformance 1 }
|
|
ieee8021MstpCompliances
|
|
OBJECT IDENTIFIER ::= { ieee8021MstpConformance 2 }
|
|
|
|
-- =============================================================
|
|
-- Units of conformance
|
|
-- =============================================================
|
|
|
|
ieee8021MstpCistGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
ieee8021MstpCistBridgeIdentifier,
|
|
ieee8021MstpCistTopologyChange,
|
|
ieee8021MstpCistRegionalRootIdentifier,
|
|
ieee8021MstpCistPathCost,
|
|
ieee8021MstpCistMaxHops
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Objects for the CIST group"
|
|
::= { ieee8021MstpGroups 1 }
|
|
|
|
ieee8021MstpGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
ieee8021MstpBridgeId,
|
|
ieee8021MstpTimeSinceTopologyChange,
|
|
ieee8021MstpTopologyChanges,
|
|
ieee8021MstpTopologyChange,
|
|
ieee8021MstpDesignatedRoot,
|
|
ieee8021MstpRootPathCost,
|
|
ieee8021MstpRootPort,
|
|
ieee8021MstpBridgePriority,
|
|
ieee8021MstpVids0,
|
|
ieee8021MstpVids1,
|
|
ieee8021MstpVids2,
|
|
ieee8021MstpVids3,
|
|
ieee8021MstpRowStatus
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Objects for the MST group"
|
|
::= { ieee8021MstpGroups 2 }
|
|
|
|
ieee8021MstpCistPortGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
ieee8021MstpCistPortUptime,
|
|
ieee8021MstpCistPortAdminPathCost,
|
|
ieee8021MstpCistPortDesignatedRoot,
|
|
ieee8021MstpCistPortTopologyChangeAck,
|
|
ieee8021MstpCistPortHelloTime,
|
|
ieee8021MstpCistPortAdminEdgePort,
|
|
ieee8021MstpCistPortOperEdgePort,
|
|
ieee8021MstpCistPortMacEnabled,
|
|
ieee8021MstpCistPortMacOperational,
|
|
ieee8021MstpCistPortRestrictedRole,
|
|
ieee8021MstpCistPortRestrictedTcn,
|
|
ieee8021MstpCistPortRole,
|
|
ieee8021MstpCistPortDisputed,
|
|
ieee8021MstpCistPortCistRegionalRootId,
|
|
ieee8021MstpCistPortCistPathCost,
|
|
ieee8021MstpCistPortProtocolMigration,
|
|
ieee8021MstpCistPortEnableBPDURx,
|
|
ieee8021MstpCistPortEnableBPDUTx,
|
|
ieee8021MstpCistPortPseudoRootId,
|
|
ieee8021MstpCistPortIsL2Gp
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Objects for the CIST Port group"
|
|
::= { ieee8021MstpGroups 3 }
|
|
|
|
ieee8021MstpPortGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
ieee8021MstpPortUptime,
|
|
ieee8021MstpPortState,
|
|
ieee8021MstpPortPriority,
|
|
ieee8021MstpPortPathCost,
|
|
ieee8021MstpPortDesignatedRoot,
|
|
ieee8021MstpPortDesignatedCost,
|
|
ieee8021MstpPortDesignatedBridge,
|
|
ieee8021MstpPortDesignatedPort,
|
|
ieee8021MstpPortRole,
|
|
ieee8021MstpPortDisputed,
|
|
ieee8021MstpPortAdminPathCost
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Objects for the MST Port group"
|
|
::= { ieee8021MstpGroups 4 }
|
|
|
|
ieee8021MstpFidToMstiGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
ieee8021MstpFidToMstiMstId
|
|
}
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"Objects for the MST FID to MSTID Allocation Table group"
|
|
::= { ieee8021MstpGroups 5 }
|
|
|
|
ieee8021MstpVlanGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
ieee8021MstpVlanMstId
|
|
}
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"Objects for the MST Configuration Table group"
|
|
::= { ieee8021MstpGroups 6 }
|
|
|
|
|
|
ieee8021MstpConfigIdGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
ieee8021MstpConfigIdFormatSelector,
|
|
ieee8021MstpConfigurationName,
|
|
ieee8021MstpRevisionLevel,
|
|
ieee8021MstpConfigurationDigest
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Objects for the MST Configuration Identifier group"
|
|
::= { ieee8021MstpGroups 7 }
|
|
|
|
|
|
ieee8021MstpCistPortExtensionGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
ieee8021MstpCistPortAutoEdgePort,
|
|
ieee8021MstpCistPortAutoIsolatePort
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Objects for the CIST Port Extension group
|
|
for fragile Bridges"
|
|
::= { ieee8021MstpGroups 8 }
|
|
|
|
ieee8021MstpFidToMstiV2Group OBJECT-GROUP
|
|
OBJECTS {
|
|
ieee8021MstpFidToMstiV2MstId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Objects for the MST FID to MSTID Allocation Table group
|
|
for SPB"
|
|
::= { ieee8021MstpGroups 9 }
|
|
|
|
ieee8021MstpVlanV2Group OBJECT-GROUP
|
|
OBJECTS {
|
|
ieee8021MstpVlanV2MstId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Objects for the MST Configuration Table group for SPB"
|
|
::= { ieee8021MstpGroups 10 }
|
|
|
|
-- =============================================================
|
|
-- Compliance statements
|
|
-- =============================================================
|
|
|
|
ieee8021MstpCompliance MODULE-COMPLIANCE
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"The compliance statement for devices supporting Multiple
|
|
Spanning Tree as defined in 13 of IEEE Std 802.1Q."
|
|
|
|
MODULE
|
|
MANDATORY-GROUPS {
|
|
ieee8021MstpCistGroup,
|
|
ieee8021MstpGroup,
|
|
ieee8021MstpCistPortGroup,
|
|
ieee8021MstpPortGroup,
|
|
ieee8021MstpFidToMstiGroup,
|
|
ieee8021MstpVlanGroup,
|
|
ieee8021MstpConfigIdGroup
|
|
}
|
|
|
|
GROUP ieee8021MstpCistPortExtensionGroup
|
|
DESCRIPTION
|
|
"Implementation of this group is optional."
|
|
|
|
::= { ieee8021MstpCompliances 1 }
|
|
|
|
ieee8021MstpComplianceV2 MODULE-COMPLIANCE
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The compliance statement for devices supporting Multiple
|
|
Spanning Tree as defined in 13 of IEEE Std 802.1Q."
|
|
|
|
MODULE
|
|
MANDATORY-GROUPS {
|
|
ieee8021MstpCistGroup,
|
|
ieee8021MstpGroup,
|
|
ieee8021MstpCistPortGroup,
|
|
ieee8021MstpPortGroup,
|
|
ieee8021MstpFidToMstiV2Group,
|
|
ieee8021MstpVlanV2Group,
|
|
ieee8021MstpConfigIdGroup
|
|
}
|
|
|
|
GROUP ieee8021MstpCistPortExtensionGroup
|
|
DESCRIPTION
|
|
"Implementation of this group is optional."
|
|
|
|
::= { ieee8021MstpCompliances 2 }
|
|
|
|
END |