1769 lines
64 KiB
Plaintext
1769 lines
64 KiB
Plaintext
FRSLD-MIB DEFINITIONS ::= BEGIN
|
|
|
|
IMPORTS
|
|
MODULE-IDENTITY, OBJECT-TYPE,
|
|
Counter32, Gauge32, Integer32,
|
|
Counter64, TimeTicks, mib-2 FROM SNMPv2-SMI
|
|
CounterBasedGauge64 FROM HCNUM-TC
|
|
TEXTUAL-CONVENTION, RowStatus,
|
|
TimeStamp FROM SNMPv2-TC
|
|
MODULE-COMPLIANCE, OBJECT-GROUP FROM SNMPv2-CONF
|
|
ifIndex FROM IF-MIB
|
|
DLCI FROM FRAME-RELAY-DTE-MIB;
|
|
|
|
frsldMIB MODULE-IDENTITY
|
|
LAST-UPDATED "200201030000Z" -- January 3, 2002
|
|
ORGANIZATION "IETF Frame Relay Service MIB Working Group"
|
|
CONTACT-INFO
|
|
"IETF Frame Relay Service MIB (frnetmib) Working Group
|
|
|
|
WG Charter: http://www.ietf.org/html.charters/
|
|
frnetmib-charter.html
|
|
WG-email: frnetmib@sunroof.eng.sun.com
|
|
Subscribe: frnetmib-request@sunroof.eng.sun.com
|
|
Email Archive: ftp://ftp.ietf.org/ietf-mail-archive/frnetmib
|
|
|
|
Chair: Andy Malis
|
|
Vivace Networks
|
|
Email: Andy.Malis@vivacenetworks.com
|
|
|
|
WG editor: Robert Steinberger
|
|
Paradyne Networks and
|
|
Fujitsu Network Communications
|
|
Email: robert.steinberger@fnc.fujitsu.com
|
|
|
|
Co-author: Orly Nicklass
|
|
RAD Data Communications Ltd.
|
|
EMail: Orly_n@rad.co.il"
|
|
DESCRIPTION
|
|
"The MIB module to describe generic objects for
|
|
FRF.13 Frame Relay Service Level Definitions."
|
|
REVISION "200201030000Z" -- January 3, 2002
|
|
DESCRIPTION
|
|
"Initial version, published as RFC 3202"
|
|
::= { mib-2 95 }
|
|
|
|
--
|
|
-- Textual Conventions
|
|
--
|
|
FrsldTxRP ::= TEXTUAL-CONVENTION
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The reference point a PVC uses for calculation
|
|
of transmitter related statistics.
|
|
|
|
The valid values for this type of object are as follows:
|
|
- srcLocalRP(1) for the local source
|
|
- ingTxLocalRP(2) for the local ingress queue input
|
|
- tpTxLocalRP(3) for the local traffic policing
|
|
- eqiTxLocalRP(4) for the local egress queue input
|
|
- eqoTxLocalRP(5) for the local egress queue output
|
|
- otherTxLocalRP(6) for any other local transmit point
|
|
- srcRemoteRP(7) for the remote source
|
|
- ingTxLocalRP(8) for the remote ingress queue input
|
|
- tpTxLocalRP(9) for the remote traffic policing
|
|
- eqiTxRemoteRP(10) for the remote egress queue input
|
|
- eqoTxRemoteRP(11) for the remote egress queue output
|
|
- otherTxRemoteRP(12) for any other remote xmit point"
|
|
REFERENCE
|
|
"FRF.13: Section 2.3"
|
|
SYNTAX INTEGER {
|
|
srcLocalRP(1),
|
|
ingTxLocalRP(2),
|
|
tpTxLocalRP(3),
|
|
eqiTxLocalRP(4),
|
|
eqoTxLocalRP(5),
|
|
otherTxLocalRP(6),
|
|
srcRemoteRP(7),
|
|
ingTxRemoteRP(8),
|
|
tpTxRemoteRP(9),
|
|
eqiTxRemoteRP(10),
|
|
eqoTxRemoteRP(11),
|
|
otherTxRemoteRP(12)
|
|
}
|
|
|
|
FrsldRxRP ::= TEXTUAL-CONVENTION
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The reference point a PVC uses for calculation
|
|
of receiver related statistics.
|
|
|
|
The valid values for this object are as follows:
|
|
- desLocalRP(1) for the local destination
|
|
- ingRxLocalRP(2) for the local ingress queue input
|
|
- tpRxLocalRP(3) for the local traffic policing
|
|
- eqiRxLocalRP(4) for the local egress queue input
|
|
- eqoRxLocalRP(5) for the local egress queue output
|
|
- otherRxLocalRP(6) for any other local receive point
|
|
- desRemoteRP(7) for the remote destination
|
|
- ingRxRemoteRP(8) for the remote ingress input
|
|
- tpRxRemoteRP(9) for the remote traffic policing
|
|
- eqiRxRemoteRP(10) for the remote egress queue input
|
|
- eqoRxRemoteRP(11) for the remote egress queue output
|
|
- otherRxRemoteRP(12) for any other remote receive point"
|
|
REFERENCE
|
|
"FRF.13: Section 2.3"
|
|
SYNTAX INTEGER {
|
|
desLocalRP(1),
|
|
ingRxLocalRP(2),
|
|
tpRxLocalRP(3),
|
|
eqiRxLocalRP(4),
|
|
eqoRxLocalRP(5),
|
|
otherRxLocalRP(6),
|
|
desRemoteRP(7),
|
|
ingRxRemoteRP(8),
|
|
tpRxRemoteRP(9),
|
|
eqiRxRemoteRP(10),
|
|
eqoRxRemoteRP(11),
|
|
otherRxRemoteRP(12)
|
|
}
|
|
|
|
--
|
|
|
|
-- Base Objects
|
|
---
|
|
|
|
frsldObjects OBJECT IDENTIFIER ::= { frsldMIB 1 }
|
|
frsldCapabilities OBJECT IDENTIFIER ::= { frsldMIB 2 }
|
|
frsldConformance OBJECT IDENTIFIER ::= { frsldMIB 3 }
|
|
|
|
-- The Frame Relay Service Level Definitions PVC Control Table
|
|
--
|
|
-- This table is used to define and display the parameters of
|
|
-- service level definitions on individual PVCs.
|
|
|
|
frsldPvcCtrlTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF FrsldPvcCtrlEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The Frame Relay Service Level Definitions
|
|
PVC control table."
|
|
::= { frsldObjects 1 }
|
|
|
|
frsldPvcCtrlEntry OBJECT-TYPE
|
|
SYNTAX FrsldPvcCtrlEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry in the Frame Relay Service Level
|
|
Definitions PVC control table."
|
|
INDEX { ifIndex, frsldPvcCtrlDlci,
|
|
frsldPvcCtrlTransmitRP, frsldPvcCtrlReceiveRP}
|
|
::= { frsldPvcCtrlTable 1 }
|
|
|
|
FrsldPvcCtrlEntry ::=
|
|
SEQUENCE {
|
|
--
|
|
-- Index Control Variables
|
|
--
|
|
frsldPvcCtrlDlci DLCI,
|
|
frsldPvcCtrlTransmitRP FrsldTxRP,
|
|
frsldPvcCtrlReceiveRP FrsldRxRP,
|
|
frsldPvcCtrlStatus RowStatus,
|
|
--
|
|
-- Service Level Definitions Setup Variables
|
|
--
|
|
frsldPvcCtrlPacketFreq Integer32,
|
|
--
|
|
-- Delay Specific Setup Variables
|
|
--
|
|
|
|
frsldPvcCtrlDelayFrSize Integer32,
|
|
frsldPvcCtrlDelayType INTEGER,
|
|
frsldPvcCtrlDelayTimeOut Integer32,
|
|
--
|
|
-- Data Persistence Control Variables
|
|
--
|
|
frsldPvcCtrlPurge Integer32,
|
|
frsldPvcCtrlDeleteOnPurge INTEGER,
|
|
frsldPvcCtrlLastPurgeTime TimeStamp
|
|
}
|
|
|
|
frsldPvcCtrlDlci OBJECT-TYPE
|
|
SYNTAX DLCI
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of this object is equal to the DLCI
|
|
value for this PVC."
|
|
::= { frsldPvcCtrlEntry 1 }
|
|
|
|
frsldPvcCtrlTransmitRP OBJECT-TYPE
|
|
SYNTAX FrsldTxRP
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The reference point this PVC uses for calculation
|
|
of transmitter related statistics. This object
|
|
together with frsldPvcCtrlReceiveRP define the
|
|
measurement domain."
|
|
REFERENCE
|
|
"FRF.13: Section 2.3"
|
|
::= { frsldPvcCtrlEntry 2 }
|
|
|
|
frsldPvcCtrlReceiveRP OBJECT-TYPE
|
|
SYNTAX FrsldRxRP
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The reference point this PVC uses for calculation
|
|
of receiver related statistics. This object
|
|
together with frsldPvcCtrlTransmitRP define the
|
|
measurement domain."
|
|
::= { frsldPvcCtrlEntry 3 }
|
|
|
|
frsldPvcCtrlStatus OBJECT-TYPE
|
|
SYNTAX RowStatus
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The status of the current row. This object is
|
|
used to add, delete, and disable rows in this
|
|
table. When the status changes to active(1) for the
|
|
first time, a row will also be added to the data
|
|
table below. This row SHOULD not be removed until
|
|
the status is changed to deleted.
|
|
|
|
When this object is set to destroy(6), all associated
|
|
sample and data table rows will also be deleted.
|
|
When this object is changed from active(1) to any
|
|
other valid value, the defined purge behavior will
|
|
affect the data and sample tables.
|
|
|
|
The rows added to this table MUST have a valid
|
|
ifIndex and an ifType related to frame relay. Further,
|
|
the reference points referred to by frsldPvcCtrlTransmitRP
|
|
and frsldPvcCtrlReceiveRP MUST be supported (see the
|
|
frsldRPCaps object).
|
|
|
|
If at any point the row is not in the active(1) state
|
|
and the DLCI no longer exists, the state SHOULD
|
|
report notReady(3).
|
|
|
|
The data in this table SHOULD persist through power
|
|
cycles. The symantics of readiness for the rows still
|
|
applies. This means that it is possible for a row to be
|
|
reprovisioned as notReady(3) if the underlying DLCI does
|
|
not persist."
|
|
::= { frsldPvcCtrlEntry 4 }
|
|
|
|
frsldPvcCtrlPacketFreq OBJECT-TYPE
|
|
SYNTAX Integer32 (0..3600)
|
|
UNITS "seconds"
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The frequency in seconds between initiation of
|
|
specialized packets used to collect delay and / or
|
|
delivery information as supported by the device.
|
|
A value of zero indicates that no packets will
|
|
be sent."
|
|
DEFVAL { 60 }
|
|
::= { frsldPvcCtrlEntry 5 }
|
|
|
|
frsldPvcCtrlDelayFrSize OBJECT-TYPE
|
|
SYNTAX Integer32 (1..8188)
|
|
UNITS "octets"
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The size of the payload in the frame used for
|
|
calculation of network delay."
|
|
DEFVAL { 128 }
|
|
::= { frsldPvcCtrlEntry 6 }
|
|
|
|
frsldPvcCtrlDelayType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
oneWay(1),
|
|
roundTrip(2)
|
|
}
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The type of delay measurement performed."
|
|
REFERENCE
|
|
"FRF.13: Section 3"
|
|
::= { frsldPvcCtrlEntry 7 }
|
|
|
|
frsldPvcCtrlDelayTimeOut OBJECT-TYPE
|
|
SYNTAX Integer32 (1..3600)
|
|
UNITS "seconds"
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A delay frame will count as a missed poll if
|
|
it is not updated in the time specified by
|
|
frsldPvcCtrlDelayTimeOut."
|
|
DEFVAL { 60 }
|
|
::= { frsldPvcCtrlEntry 8 }
|
|
|
|
frsldPvcCtrlPurge OBJECT-TYPE
|
|
SYNTAX Integer32 (0..172800) -- up to 48 hours
|
|
UNITS "seconds"
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object defines the amount of time the device
|
|
will wait, after discovering that a DLCI does not exist,
|
|
the DLCI was deleted or the value of frsldPvcCtrlStatus
|
|
changes from active(1) to either notInService(2) or
|
|
notReady(3), prior to automatically purging the history
|
|
in the sample tables and resetting the data in the data
|
|
tables to all zeroes. If frsldPvcCtrlStatus is manually
|
|
set to destroy(6), this object does not apply."
|
|
DEFVAL { 0 }
|
|
::= { frsldPvcCtrlEntry 9 }
|
|
|
|
frsldPvcCtrlDeleteOnPurge OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
none(1),
|
|
sampleContols(2),
|
|
all(3)
|
|
}
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object defines whether rows will
|
|
automatically be deleted from the tables
|
|
when the information is purged.
|
|
|
|
- A value of none(1) indicates that no rows
|
|
will deleted. The last known values will
|
|
be preserved.
|
|
- A value of sampleControls(2) indicates
|
|
that all associated sample control rows
|
|
will be deleted.
|
|
- A value of all(3) indicates that all
|
|
associated rows SHOULD be deleted."
|
|
DEFVAL { all }
|
|
::= { frsldPvcCtrlEntry 10 }
|
|
|
|
frsldPvcCtrlLastPurgeTime OBJECT-TYPE
|
|
SYNTAX TimeStamp
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object returns the value of sysUpTime
|
|
at the time the information was last purged.
|
|
This value SHOULD be set to the sysUpTime
|
|
upon setting frsldPvcCtrlStatus to active(1)
|
|
for the first time. Each time a
|
|
discontinuity in the counters occurs, this
|
|
value MUST be set to the sysUpTime.
|
|
|
|
If frsldPvcCtrlStatus has never been active(1),
|
|
this object SHOULD return 0.
|
|
|
|
This object SHOULD be used as the discontinuity
|
|
timer for the counters in frsldPvcDataTable."
|
|
::= { frsldPvcCtrlEntry 11 }
|
|
|
|
-- The Frame Relay Service Level Definitions Sampling Control
|
|
-- Table
|
|
|
|
--
|
|
-- This table is used to define the sample control parameters
|
|
-- of service level definitions on individual PVCs.
|
|
|
|
frsldSmplCtrlTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF FrsldSmplCtrlEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The Frame Relay Service Level Definitions
|
|
sampling control table."
|
|
::= { frsldObjects 2 }
|
|
|
|
frsldSmplCtrlEntry OBJECT-TYPE
|
|
SYNTAX FrsldSmplCtrlEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry in the Frame Relay Service Level
|
|
Definitions sample control table."
|
|
INDEX { ifIndex, frsldPvcCtrlDlci,
|
|
frsldPvcCtrlTransmitRP, frsldPvcCtrlReceiveRP,
|
|
frsldSmplCtrlIdx }
|
|
::= { frsldSmplCtrlTable 1 }
|
|
|
|
FrsldSmplCtrlEntry ::=
|
|
SEQUENCE {
|
|
--
|
|
-- Index Control Variables
|
|
--
|
|
frsldSmplCtrlIdx Integer32,
|
|
frsldSmplCtrlStatus RowStatus,
|
|
--
|
|
-- Collection Control Variables
|
|
--
|
|
frsldSmplCtrlColPeriod Integer32,
|
|
frsldSmplCtrlBuckets Integer32,
|
|
frsldSmplCtrlBucketsGranted Integer32
|
|
}
|
|
|
|
frsldSmplCtrlIdx OBJECT-TYPE
|
|
SYNTAX Integer32 (1..256)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The unique index for this row in the
|
|
sample control table."
|
|
::= { frsldSmplCtrlEntry 1 }
|
|
|
|
frsldSmplCtrlStatus OBJECT-TYPE
|
|
SYNTAX RowStatus
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The status of the current row. This object is
|
|
used to add, delete, and disable rows in this
|
|
table. This row SHOULD NOT be removed until the
|
|
status is changed to destroy(6). When the status
|
|
changes to active(1), the collection in the sample
|
|
tables below will be activated.
|
|
|
|
The rows added to this table MUST have a valid
|
|
ifIndex, an ifType related to frame relay,
|
|
frsldPvcCtrlDlci MUST exist for the specified
|
|
ifIndex and frsldPvcCtrlStatus MUST have a
|
|
value of active(1).
|
|
|
|
The value of frsldPvcCtrlStatus MUST be active(1)
|
|
to transition this object to active(1). If
|
|
the value of frsldPvcCtrlStatus becomes anything
|
|
other than active(1) when the state of this object
|
|
is not active(1), this object SHOULD be set to
|
|
notReady(3).
|
|
|
|
The data in this table SHOULD persist through power
|
|
cycles. The symantics of readiness for the rows still
|
|
applies. This means that it is possible for a row to be
|
|
reprovisioned as notReady(3) if the underlying DLCI does
|
|
not persist."
|
|
::= { frsldSmplCtrlEntry 2 }
|
|
|
|
frsldSmplCtrlColPeriod OBJECT-TYPE
|
|
SYNTAX Integer32 (1..2147483647)
|
|
UNITS "seconds"
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The amount of time in seconds that defines a
|
|
period of collection for the statistics.
|
|
At the end of each period, the statistics will be
|
|
sampled and a row is added to the sample table."
|
|
::= { frsldSmplCtrlEntry 3 }
|
|
|
|
frsldSmplCtrlBuckets OBJECT-TYPE
|
|
SYNTAX Integer32 (1..65535)
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of discrete buckets over which the
|
|
data statistics are sampled.
|
|
|
|
When this object is created or modified, the device
|
|
SHOULD attempt to set the frsldSmplCtrlBuckets-
|
|
Granted to a value as close as is possible
|
|
depending upon the implementation and the available
|
|
resources."
|
|
DEFVAL { 60 }
|
|
::= { frsldSmplCtrlEntry 4 }
|
|
|
|
frsldSmplCtrlBucketsGranted OBJECT-TYPE
|
|
SYNTAX Integer32 (0..65535)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of discrete buckets granted. This
|
|
object will return 0 until frsldSmplCtrlStatus is
|
|
set to active(1). At that time the buckets will be
|
|
allocated depending upon implementation and
|
|
available resources."
|
|
::= { frsldSmplCtrlEntry 5 }
|
|
|
|
-- The Frame Relay Service Level Definitions PVC Data Table
|
|
--
|
|
-- This table contains the accumulated values of
|
|
-- the collected data. This table is the table that should
|
|
-- be referenced by external polling mechanisms if time
|
|
-- based polling be desired.
|
|
|
|
frsldPvcDataTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF FrsldPvcDataEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The Frame Relay Service Level Definitions
|
|
data table.
|
|
|
|
This table contains accumulated values of the
|
|
collected data. It is the table that should be
|
|
referenced by external polling mechanisms if
|
|
time based polling be desired."
|
|
::= { frsldObjects 3 }
|
|
|
|
frsldPvcDataEntry OBJECT-TYPE
|
|
SYNTAX FrsldPvcDataEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry in the Frame Relay Service Level
|
|
Definitions data table."
|
|
INDEX { ifIndex, frsldPvcCtrlDlci,
|
|
frsldPvcCtrlTransmitRP, frsldPvcCtrlReceiveRP}
|
|
::= { frsldPvcDataTable 1 }
|
|
|
|
FrsldPvcDataEntry ::=
|
|
SEQUENCE {
|
|
frsldPvcDataMissedPolls Counter32,
|
|
frsldPvcDataFrDeliveredC Counter32,
|
|
frsldPvcDataFrDeliveredE Counter32,
|
|
frsldPvcDataFrOfferedC Counter32,
|
|
frsldPvcDataFrOfferedE Counter32,
|
|
frsldPvcDataDataDeliveredC Counter32,
|
|
frsldPvcDataDataDeliveredE Counter32,
|
|
frsldPvcDataDataOfferedC Counter32,
|
|
frsldPvcDataDataOfferedE Counter32,
|
|
frsldPvcDataHCFrDeliveredC Counter64,
|
|
frsldPvcDataHCFrDeliveredE Counter64,
|
|
frsldPvcDataHCFrOfferedC Counter64,
|
|
frsldPvcDataHCFrOfferedE Counter64,
|
|
frsldPvcDataHCDataDeliveredC Counter64,
|
|
frsldPvcDataHCDataDeliveredE Counter64,
|
|
frsldPvcDataHCDataOfferedC Counter64,
|
|
frsldPvcDataHCDataOfferedE Counter64,
|
|
frsldPvcDataUnavailableTime TimeTicks,
|
|
frsldPvcDataUnavailables Counter32
|
|
}
|
|
|
|
frsldPvcDataMissedPolls OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The total number of polls that have been determined
|
|
to be missed. These polls are typically associated
|
|
with the calculation of delay but may also be
|
|
used for the calculation of other statistics. If an
|
|
anticipated poll is not received in a reasonable
|
|
amount of time, it should be counted as missed.
|
|
The value used to determine the reasonable amount
|
|
of time is contained in frsldPvcCtrlDelayTimeOut.
|
|
|
|
Discontinuities in the value of this counter can
|
|
occur at re-initialization of the management system
|
|
and at other times as indicated by
|
|
|
|
frsldPvcCtrlLastPurgeTime."
|
|
::= { frsldPvcDataEntry 1 }
|
|
|
|
frsldPvcDataFrDeliveredC OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of frames that were received at
|
|
frsldPvcCtrlReceiveRP and determined to have been
|
|
sent within CIR.
|
|
|
|
Discontinuities in the value of this counter can
|
|
occur at re-initialization of the management system
|
|
and at other times as indicated by
|
|
frsldPvcCtrlLastPurgeTime."
|
|
REFERENCE
|
|
"FRF.13: Section 4.1 (FramesDeliveredc)"
|
|
::= { frsldPvcDataEntry 2 }
|
|
|
|
frsldPvcDataFrDeliveredE OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of frames that were received at
|
|
frsldPvcCtrlReceiveRP and determined to have been
|
|
sent in excess of the CIR.
|
|
|
|
Discontinuities in the value of this counter can
|
|
occur at re-initialization of the management system
|
|
and at other times as indicated by
|
|
frsldPvcCtrlLastPurgeTime."
|
|
REFERENCE
|
|
"FRF.13: Section 4.1 (FramesDeliverede)"
|
|
::= { frsldPvcDataEntry 3 }
|
|
|
|
frsldPvcDataFrOfferedC OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of frames that were offered through
|
|
frsldPvcCtrlTransmitRP within CIR.
|
|
|
|
Discontinuities in the value of this counter can
|
|
occur at re-initialization of the management system
|
|
and at other times as indicated by
|
|
|
|
frsldPvcCtrlLastPurgeTime."
|
|
REFERENCE
|
|
"FRF.13: Section 4.1 (FramesOfferedc)"
|
|
::= { frsldPvcDataEntry 4 }
|
|
|
|
frsldPvcDataFrOfferedE OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of frames that were offered through
|
|
frsldPvcCtrlTransmitRP in excess of the CIR.
|
|
|
|
Discontinuities in the value of this counter can
|
|
occur at re-initialization of the management system
|
|
and at other times as indicated by
|
|
frsldPvcCtrlLastPurgeTime."
|
|
REFERENCE
|
|
"FRF.13: Section 4.1 (FramesOfferede)"
|
|
::= { frsldPvcDataEntry 5 }
|
|
|
|
frsldPvcDataDataDeliveredC OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of octets that were received at
|
|
frsldPvcCtrlReceiveRP and determined to have been
|
|
sent within CIR.
|
|
|
|
Discontinuities in the value of this counter can
|
|
occur at re-initialization of the management system
|
|
and at other times as indicated by
|
|
frsldPvcCtrlLastPurgeTime."
|
|
REFERENCE
|
|
"FRF.13: Section 5.1 (DataDeliveredc)"
|
|
::= { frsldPvcDataEntry 6 }
|
|
|
|
frsldPvcDataDataDeliveredE OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of octets that were received at
|
|
frsldPvcCtrlReceiveRP and determined to have been
|
|
sent in excess of the CIR.
|
|
|
|
Discontinuities in the value of this counter can
|
|
|
|
occur at re-initialization of the management system
|
|
and at other times as indicated by
|
|
frsldPvcCtrlLastPurgeTime."
|
|
REFERENCE
|
|
"FRF.13: Section 5.1 (DataDeliverede)"
|
|
::= { frsldPvcDataEntry 7 }
|
|
|
|
frsldPvcDataDataOfferedC OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of octets that were offered through
|
|
frsldPvcCtrlTransmitRP within CIR.
|
|
|
|
Discontinuities in the value of this counter can
|
|
occur at re-initialization of the management system
|
|
and at other times as indicated by
|
|
frsldPvcCtrlLastPurgeTime."
|
|
REFERENCE
|
|
"FRF.13: Section 5.1 (DataOfferedc)"
|
|
::= { frsldPvcDataEntry 8 }
|
|
|
|
frsldPvcDataDataOfferedE OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of octets that were offered through
|
|
frsldPvcCtrlTransmitRP in excess of the CIR.
|
|
|
|
Discontinuities in the value of this counter can
|
|
occur at re-initialization of the management system
|
|
and at other times as indicated by
|
|
frsldPvcCtrlLastPurgeTime."
|
|
REFERENCE
|
|
"FRF.13: Section 5.1 (DataOfferede)"
|
|
::= { frsldPvcDataEntry 9 }
|
|
|
|
frsldPvcDataHCFrDeliveredC OBJECT-TYPE
|
|
SYNTAX Counter64
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of frames that were received at
|
|
frsldPvcCtrlReceiveRP and determined to have been
|
|
sent within CIR. This object is a 64-bit version
|
|
of frsldPvcDataFrDeliveredC.
|
|
|
|
Discontinuities in the value of this counter can
|
|
occur at re-initialization of the management system
|
|
and at other times as indicated by
|
|
frsldPvcCtrlLastPurgeTime."
|
|
REFERENCE
|
|
"FRF.13: Section 4.1 (FramesDeliveredc)"
|
|
::= { frsldPvcDataEntry 10 }
|
|
|
|
frsldPvcDataHCFrDeliveredE OBJECT-TYPE
|
|
SYNTAX Counter64
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of frames that were received at
|
|
frsldPvcCtrlReceiveRP and determined to have been
|
|
sent in excess of the CIR. This object is a 64-bit
|
|
version of frsldPvcDataFrDeliveredE.
|
|
|
|
Discontinuities in the value of this counter can
|
|
occur at re-initialization of the management system
|
|
and at other times as indicated by
|
|
frsldPvcCtrlLastPurgeTime."
|
|
REFERENCE
|
|
"FRF.13: Section 4.1 (FramesDeliverede)"
|
|
::= { frsldPvcDataEntry 11 }
|
|
|
|
frsldPvcDataHCFrOfferedC OBJECT-TYPE
|
|
SYNTAX Counter64
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of frames that were offered through
|
|
frsldPvcCtrlTransmitRP within CIR. This object is
|
|
a 64-bit version of frsldPvcDataFrOfferedC.
|
|
|
|
Discontinuities in the value of this counter can
|
|
occur at re-initialization of the management system
|
|
and at other times as indicated by
|
|
frsldPvcCtrlLastPurgeTime."
|
|
REFERENCE
|
|
"FRF.13: Section 4.1 (FramesOfferedc)"
|
|
::= { frsldPvcDataEntry 12 }
|
|
|
|
frsldPvcDataHCFrOfferedE OBJECT-TYPE
|
|
SYNTAX Counter64
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of frames that were offered through
|
|
frsldPvcCtrlTransmitRP in excess of the CIR. This
|
|
object is a 64-bit version of frsldPvcDataFrOfferedE.
|
|
|
|
Discontinuities in the value of this counter can
|
|
occur at re-initialization of the management system
|
|
and at other times as indicated by
|
|
frsldPvcCtrlLastPurgeTime."
|
|
REFERENCE
|
|
"FRF.13: Section 4.1 (FramesOfferede)"
|
|
::= { frsldPvcDataEntry 13 }
|
|
|
|
frsldPvcDataHCDataDeliveredC OBJECT-TYPE
|
|
SYNTAX Counter64
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of octets that were received at
|
|
frsldPvcCtrlReceiveRP and determined to have been
|
|
sent within CIR. This object is a 64-bit version of
|
|
frsldPvcDataDataDeliveredC.
|
|
|
|
Discontinuities in the value of this counter can
|
|
occur at re-initialization of the management system
|
|
and at other times as indicated by
|
|
frsldPvcCtrlLastPurgeTime."
|
|
REFERENCE
|
|
"FRF.13: Section 5.1 (DataDeliveredc)"
|
|
::= { frsldPvcDataEntry 14 }
|
|
|
|
frsldPvcDataHCDataDeliveredE OBJECT-TYPE
|
|
SYNTAX Counter64
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of octets that were received at
|
|
frsldPvcCtrlReceiveRP and determined to have been
|
|
sent in excess of the CIR. This object is a 64-bit
|
|
version of frsldPvcDataDataDeliveredE.
|
|
|
|
Discontinuities in the value of this counter can
|
|
occur at re-initialization of the management system
|
|
and at other times as indicated by
|
|
frsldPvcCtrlLastPurgeTime."
|
|
REFERENCE
|
|
"FRF.13: Section 5.1 (DataDeliverede)"
|
|
::= { frsldPvcDataEntry 15 }
|
|
|
|
frsldPvcDataHCDataOfferedC OBJECT-TYPE
|
|
SYNTAX Counter64
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of octets that were offered through
|
|
frsldPvcCtrlTransmitRP within CIR. This object is
|
|
a 64-bit version of frsldPvcDataDataOfferedC.
|
|
|
|
Discontinuities in the value of this counter can
|
|
occur at re-initialization of the management system
|
|
and at other times as indicated by
|
|
frsldPvcCtrlLastPurgeTime."
|
|
REFERENCE
|
|
"FRF.13: Section 5.1 (DataOfferedc)"
|
|
::= { frsldPvcDataEntry 16 }
|
|
|
|
frsldPvcDataHCDataOfferedE OBJECT-TYPE
|
|
SYNTAX Counter64
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of octets that were offered through
|
|
frsldPvcCtrlTransmitRP in excess of the CIR.
|
|
This object is a 64-bit version of
|
|
frsldPvcDataDataOfferedE.
|
|
|
|
Discontinuities in the value of this counter can
|
|
occur at re-initialization of the management system
|
|
and at other times as indicated by
|
|
frsldPvcCtrlLastPurgeTime."
|
|
REFERENCE
|
|
"FRF.13: Section 5.1 (DataOfferede)"
|
|
::= { frsldPvcDataEntry 17 }
|
|
|
|
frsldPvcDataUnavailableTime OBJECT-TYPE
|
|
SYNTAX TimeTicks
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The amount of time this PVC was declared unavailable
|
|
for any reason since this row was created."
|
|
REFERENCE
|
|
"FRF.13: Section 6.1 (OutageTime)"
|
|
::= { frsldPvcDataEntry 18 }
|
|
|
|
frsldPvcDataUnavailables OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of times this PVC was declared unavailable
|
|
for any reason since this row was created.
|
|
|
|
Discontinuities in the value of this counter can
|
|
occur at re-initialization of the management system
|
|
and at other times as indicated by
|
|
frsldPvcCtrlLastPurgeTime."
|
|
REFERENCE
|
|
"FRF.13: Section 6.1 (OutageCount)"
|
|
::= { frsldPvcDataEntry 19 }
|
|
|
|
-- The Frame Relay Service Level Definitions PVC Sample Table
|
|
--
|
|
-- This table contains the sampled delay, delivery and
|
|
-- availability information.
|
|
|
|
frsldPvcSampleTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF FrsldPvcSampleEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The Frame Relay Service Level Definitions
|
|
sample table."
|
|
::= { frsldObjects 4 }
|
|
|
|
frsldPvcSampleEntry OBJECT-TYPE
|
|
SYNTAX FrsldPvcSampleEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry in the Frame Relay Service Level
|
|
Definitions data sample table."
|
|
INDEX { ifIndex, frsldPvcCtrlDlci,
|
|
frsldPvcCtrlTransmitRP, frsldPvcCtrlReceiveRP,
|
|
frsldSmplCtrlIdx, frsldPvcSmplIdx }
|
|
::= { frsldPvcSampleTable 1 }
|
|
|
|
FrsldPvcSampleEntry ::=
|
|
SEQUENCE {
|
|
frsldPvcSmplIdx Integer32,
|
|
frsldPvcSmplDelayMin Gauge32,
|
|
frsldPvcSmplDelayMax Gauge32,
|
|
frsldPvcSmplDelayAvg Gauge32,
|
|
frsldPvcSmplMissedPolls Gauge32,
|
|
frsldPvcSmplFrDeliveredC Gauge32,
|
|
frsldPvcSmplFrDeliveredE Gauge32,
|
|
frsldPvcSmplFrOfferedC Gauge32,
|
|
frsldPvcSmplFrOfferedE Gauge32,
|
|
frsldPvcSmplDataDeliveredC Gauge32,
|
|
frsldPvcSmplDataDeliveredE Gauge32,
|
|
frsldPvcSmplDataOfferedC Gauge32,
|
|
frsldPvcSmplDataOfferedE Gauge32,
|
|
frsldPvcSmplHCFrDeliveredC CounterBasedGauge64,
|
|
frsldPvcSmplHCFrDeliveredE CounterBasedGauge64,
|
|
frsldPvcSmplHCFrOfferedC CounterBasedGauge64,
|
|
frsldPvcSmplHCFrOfferedE CounterBasedGauge64,
|
|
frsldPvcSmplHCDataDeliveredC CounterBasedGauge64,
|
|
frsldPvcSmplHCDataDeliveredE CounterBasedGauge64,
|
|
frsldPvcSmplHCDataOfferedC CounterBasedGauge64,
|
|
frsldPvcSmplHCDataOfferedE CounterBasedGauge64,
|
|
frsldPvcSmplUnavailableTime TimeTicks,
|
|
frsldPvcSmplUnavailables Gauge32,
|
|
frsldPvcSmplStartTime TimeStamp,
|
|
frsldPvcSmplEndTime TimeStamp
|
|
}
|
|
|
|
frsldPvcSmplIdx OBJECT-TYPE
|
|
SYNTAX Integer32 (1..2147483647)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The bucket index of the current sample. This
|
|
increments once for each new bucket in the
|
|
table."
|
|
::= { frsldPvcSampleEntry 1 }
|
|
|
|
frsldPvcSmplDelayMin OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
UNITS "microseconds"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The minimum delay reported in microseconds measured
|
|
for any information packet that arrived during this
|
|
interval.
|
|
|
|
A value of zero means that no data is available."
|
|
REFERENCE
|
|
"FRF.13: Section 3.1 (FTD)"
|
|
::= { frsldPvcSampleEntry 2 }
|
|
|
|
frsldPvcSmplDelayMax OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
UNITS "microseconds"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The largest delay reported in microseconds measured
|
|
for any information packet that arrived during this
|
|
interval.
|
|
|
|
A value of zero means that no data is available."
|
|
REFERENCE
|
|
"FRF.13: Section 3.1 (FTD)"
|
|
::= { frsldPvcSampleEntry 3 }
|
|
|
|
frsldPvcSmplDelayAvg OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
UNITS "microseconds"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The average delay reported in microseconds measured
|
|
for all delay packets that arrived during this
|
|
interval.
|
|
|
|
A value of zero means that no data is available."
|
|
REFERENCE
|
|
"FRF.13: Section 3.1 (FTD)"
|
|
::= { frsldPvcSampleEntry 4 }
|
|
|
|
frsldPvcSmplMissedPolls OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The total number of polls that were missed during
|
|
this interval."
|
|
::= { frsldPvcSampleEntry 5 }
|
|
|
|
frsldPvcSmplFrDeliveredC OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of frames that were received at
|
|
frsldPvcCtrlReceiveRP and determined to have been
|
|
sent within CIR during this interval.
|
|
|
|
If it is the case that the high capacity counters
|
|
are also used, this MUST report the value of the
|
|
|
|
lower 32 bits of the CounterBasedGauge64 value of
|
|
frsldPvcSmplHCFrDeliveredC."
|
|
REFERENCE
|
|
"FRF.13: Section 4.1 (FramesDeliveredc)"
|
|
::= { frsldPvcSampleEntry 6 }
|
|
|
|
frsldPvcSmplFrDeliveredE OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of frames that were received at
|
|
frsldPvcCtrlReceiveRP and determined to have been
|
|
sent in excess of the CIR during this interval.
|
|
|
|
If it is the case that the high capacity counters
|
|
are also used, this MUST report the value of the
|
|
lower 32 bits of the CounterBasedGauge64 value of
|
|
frsldPvcSmplHCFrDeliveredE."
|
|
REFERENCE
|
|
"FRF.13: Section 4.1 (FramesDeliverede))"
|
|
::= { frsldPvcSampleEntry 7 }
|
|
|
|
frsldPvcSmplFrOfferedC OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of frames that were offered through
|
|
frsldPvcCtrlTransmitRP within CIR during this
|
|
interval.
|
|
|
|
If it is the case that the high capacity counters
|
|
are also used, this MUST report the value of the
|
|
lower 32 bits of the CounterBasedGauge64 value of
|
|
frsldPvcSmplHCFrOfferedC."
|
|
REFERENCE
|
|
"FRF.13: Section 4.1 (FramesOfferedc)"
|
|
::= { frsldPvcSampleEntry 8 }
|
|
|
|
frsldPvcSmplFrOfferedE OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of frames that were offered through
|
|
frsldPvcCtrlTransmitRP in excess of the CIR
|
|
during this interval.
|
|
|
|
If it is the case that the high capacity counters
|
|
are also used, this MUST report the value of the
|
|
lower 32 bits of the CounterBasedGauge64 value of
|
|
frsldPvcSmplHCFrOfferedE."
|
|
REFERENCE
|
|
"FRF.13: Section 4.1 (FramesOfferede)"
|
|
::= { frsldPvcSampleEntry 9 }
|
|
|
|
frsldPvcSmplDataDeliveredC OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of octets that were received at
|
|
frsldPvcCtrlReceiveRP and determined to have been
|
|
sent within CIR during this interval.
|
|
|
|
If it is the case that the high capacity counters
|
|
are also used, this MUST report the value of the
|
|
lower 32 bits of the CounterBasedGauge64 value of
|
|
frsldPvcSmplHCDataDeliveredC."
|
|
REFERENCE
|
|
"FRF.13: Section 5.1 (DataDeliveredc)"
|
|
::= { frsldPvcSampleEntry 10 }
|
|
|
|
frsldPvcSmplDataDeliveredE OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of octets that were received at
|
|
frsldPvcCtrlDeliveredRP and determined to have been
|
|
sent in excess of the CIR during this interval.
|
|
|
|
If it is the case that the high capacity counters
|
|
are also used, this MUST report the value of the
|
|
lower 32 bits of the CounterBasedGauge64 value of
|
|
frsldPvcSmplHCDataDeliveredE."
|
|
REFERENCE
|
|
"FRF.13: Section 5.1 (DataDeliverede)"
|
|
::= { frsldPvcSampleEntry 11 }
|
|
|
|
frsldPvcSmplDataOfferedC OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of octets that were offered through
|
|
|
|
frsldPvcCtrlTransmitRP within CIR during this
|
|
interval.
|
|
|
|
If it is the case that the high capacity counters
|
|
are also used, this MUST report the value of the
|
|
lower 32 bits of the CounterBasedGauge64 value of
|
|
frsldPvcSmplHCDataOfferredC."
|
|
REFERENCE
|
|
"FRF.13: Section 5.1 (DataOfferedc)"
|
|
::= { frsldPvcSampleEntry 12 }
|
|
|
|
frsldPvcSmplDataOfferedE OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of octets that were offered through
|
|
frsldPvcCtrlTransmitRP in excess of the CIR
|
|
during this interval.
|
|
|
|
If it is the case that the high capacity counters
|
|
are also used, this MUST report the value of the
|
|
lower 32 bits of the CounterBasedGauge64 value of
|
|
frsldPvcSmplHCDataOfferedE."
|
|
REFERENCE
|
|
"FRF.13: Section 5.1 (DataOfferede)"
|
|
::= { frsldPvcSampleEntry 13 }
|
|
|
|
frsldPvcSmplHCFrDeliveredC OBJECT-TYPE
|
|
SYNTAX CounterBasedGauge64
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of frames that were received at
|
|
frsldPvcCtrlReceiveRP and determined to have been
|
|
sent within CIR during this interval. This object
|
|
is a 64-bit version of frsldPvcSmplFrDeliveredC."
|
|
REFERENCE
|
|
"FRF.13: Section 4.1 (FramesDeliveredc)"
|
|
::= { frsldPvcSampleEntry 14 }
|
|
|
|
frsldPvcSmplHCFrDeliveredE OBJECT-TYPE
|
|
SYNTAX CounterBasedGauge64
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of frames that were received at
|
|
frsldPvcCtrlReceiveRP and determined to have been
|
|
|
|
sent in excess of the CIR during this interval.
|
|
This object is a 64-bit version of frsldPvcSmpl-
|
|
FrDeliveredE."
|
|
REFERENCE
|
|
"FRF.13: Section 4.1 (FramesDeliverede)"
|
|
::= { frsldPvcSampleEntry 15 }
|
|
|
|
frsldPvcSmplHCFrOfferedC OBJECT-TYPE
|
|
SYNTAX CounterBasedGauge64
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of frames that were offered through
|
|
frsldPvcCtrlTransmitRP within CIR during this
|
|
interval. This object is a 64-bit version of
|
|
frsldPvcSmplFrOfferedC."
|
|
REFERENCE
|
|
"FRF.13: Section 4.1 (FramesOfferedc)"
|
|
::= { frsldPvcSampleEntry 16 }
|
|
|
|
frsldPvcSmplHCFrOfferedE OBJECT-TYPE
|
|
SYNTAX CounterBasedGauge64
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of frames that were offered through
|
|
frsldPvcCtrlTransmitRP in excess of the CIR
|
|
during this interval. This object is a 64-bit
|
|
version of frsldPvcSmplFrOfferedE."
|
|
REFERENCE
|
|
"FRF.13: Section 4.1 (FramesOfferede)"
|
|
::= { frsldPvcSampleEntry 17 }
|
|
|
|
frsldPvcSmplHCDataDeliveredC OBJECT-TYPE
|
|
SYNTAX CounterBasedGauge64
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of octets that were received at
|
|
frsldPvcCtrlReceiveRP and determined to have been
|
|
sent within CIR during this interval. This value
|
|
is a 64-bit version of frsldPvcSmplDataDeliveredC."
|
|
REFERENCE
|
|
"FRF.13: Section 5.1 (DataDeliveredc)"
|
|
::= { frsldPvcSampleEntry 18 }
|
|
|
|
frsldPvcSmplHCDataDeliveredE OBJECT-TYPE
|
|
SYNTAX CounterBasedGauge64
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of octets that were received at
|
|
frsldPvcCtrlReceiveRP and determined to have been
|
|
sent in excess of the CIR during this interval. This
|
|
value is a 64-bit version of frsldPvcSmplData-
|
|
DeliveredE."
|
|
REFERENCE
|
|
"FRF.13: Section 5.1 (DataDeliverede)"
|
|
::= { frsldPvcSampleEntry 19 }
|
|
|
|
frsldPvcSmplHCDataOfferedC OBJECT-TYPE
|
|
SYNTAX CounterBasedGauge64
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of octets that were offered through
|
|
frsldPvcCtrlTransmitRP within CIR during this
|
|
interval. This value is a 64-bit version of
|
|
frsldPvcSmplDataOfferedC."
|
|
REFERENCE
|
|
"FRF.13: Section 5.1 (DataOfferedc)"
|
|
::= { frsldPvcSampleEntry 20 }
|
|
|
|
frsldPvcSmplHCDataOfferedE OBJECT-TYPE
|
|
SYNTAX CounterBasedGauge64
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of octets that were offered through
|
|
frsldPvcCtrlTransmitRP in excess of the CIR
|
|
during this interval. This object is a 64-bit
|
|
version of frsldPvcSmplDataOfferedE."
|
|
REFERENCE
|
|
"FRF.13: Section 5.1 (DataOfferede)"
|
|
::= { frsldPvcSampleEntry 21 }
|
|
|
|
frsldPvcSmplUnavailableTime OBJECT-TYPE
|
|
SYNTAX TimeTicks
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The amount of time this PVC was declared
|
|
unavailable for any reason during this interval."
|
|
REFERENCE
|
|
"FRF.13: Section 6.1 (OutageTime)"
|
|
::= { frsldPvcSampleEntry 22 }
|
|
|
|
frsldPvcSmplUnavailables OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of times this PVC was declared
|
|
unavailable for any reason during this interval."
|
|
REFERENCE
|
|
"FRF.13: Section 6.1 (OutageCount)"
|
|
::= { frsldPvcSampleEntry 23 }
|
|
|
|
frsldPvcSmplStartTime OBJECT-TYPE
|
|
SYNTAX TimeStamp
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of sysUpTime when this sample interval
|
|
started."
|
|
::= { frsldPvcSampleEntry 24 }
|
|
|
|
frsldPvcSmplEndTime OBJECT-TYPE
|
|
SYNTAX TimeStamp
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of sysUpTime when this sample interval
|
|
ended. No data will be reported and the row will
|
|
not appear in the table until the sample has
|
|
been collected."
|
|
::= { frsldPvcSampleEntry 25 }
|
|
|
|
-- Capabilities Group
|
|
-- This group provides capabilities objects for the tables
|
|
-- that control configuration.
|
|
|
|
frsldPvcCtrlWriteCaps OBJECT-TYPE
|
|
SYNTAX BITS {
|
|
frsldPvcCtrlStatus(0),
|
|
frsldPvcCtrlPacketFreq(1),
|
|
frsldPvcCtrlDelayFrSize(2),
|
|
frsldPvcCtrlDelayType(3),
|
|
frsldPvcCtrlDelayTimeOut(4),
|
|
frsldPvcCtrlPurge(5),
|
|
frsldPvcCtrlDeleteOnPurge(6)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object specifies the write capabilities
|
|
for the read-create objects of the PVC Control
|
|
table. If the corresponding bit is enabled (1),
|
|
the agent supports writes to that object."
|
|
::= { frsldCapabilities 1 }
|
|
|
|
frsldSmplCtrlWriteCaps OBJECT-TYPE
|
|
SYNTAX BITS {
|
|
frsldSmplCtrlStatus(0),
|
|
frsldSmplCtrlBuckets(1)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object specifies the write capabilities
|
|
for the read-create objects of the Sample Control
|
|
table. If the corresponding bit is enabled (1),
|
|
the agent supports writes to that object."
|
|
::= { frsldCapabilities 2 }
|
|
|
|
frsldRPCaps OBJECT-TYPE
|
|
SYNTAX BITS {
|
|
srcLocalRP(0),
|
|
ingTxLocalRP(1),
|
|
tpTxLocalRP(2),
|
|
eqiTxLocalRP(3),
|
|
eqoTxLocalRP(4),
|
|
otherTxLocalRP(5),
|
|
srcRemoteRP(6),
|
|
ingTxRemoteRP(7),
|
|
tpTxRemoteRP(8),
|
|
eqiTxRemoteRP(9),
|
|
eqoTxRemoteRP(10),
|
|
otherTxRemoteRP(11),
|
|
desLocalRP(12),
|
|
ingRxLocalRP(13),
|
|
tpRxLocalRP(14),
|
|
eqiRxLocalRP(15),
|
|
eqoRxLocalRP(16),
|
|
otherRxLocalRP(17),
|
|
desRemoteRP(18),
|
|
ingRxRemoteRP(19),
|
|
tpRxRemoteRP(20),
|
|
eqiRxRemoteRP(21),
|
|
eqoRxRemoteRP(22),
|
|
otherRxRemoteRP(23)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object specifies the reference points that
|
|
the agent supports. This object allows the management
|
|
application to discover which rows can be created on
|
|
a specific device."
|
|
::= { frsldCapabilities 3 }
|
|
|
|
frsldMaxPvcCtrls OBJECT-TYPE
|
|
SYNTAX Integer32 (0..2147483647)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The maximum number of control rows that can be created
|
|
in frsldPvcCtrlTable. Sets to this object lower than
|
|
the current value of frsldNumPvcCtrls should result in
|
|
inconsistentValue."
|
|
::= { frsldCapabilities 4 }
|
|
|
|
frsldNumPvcCtrls OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The current number of rows in frsldPvcCtrlTable."
|
|
::= { frsldCapabilities 5 }
|
|
|
|
frsldMaxSmplCtrls OBJECT-TYPE
|
|
SYNTAX Integer32 (0..2147483647)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The maximum number of control rows that can be created
|
|
in frsldSmplCtrlTable. Sets to this object lower than
|
|
the current value of frsldNumSmplCtrls should result in
|
|
inconsistentValue."
|
|
::= { frsldCapabilities 6 }
|
|
|
|
frsldNumSmplCtrls OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The current number of rows in frsldSmplCtrlTable."
|
|
::= { frsldCapabilities 7 }
|
|
|
|
-- Conformance Information
|
|
|
|
frsldMIBGroups OBJECT IDENTIFIER ::= { frsldConformance 1 }
|
|
frsldMIBCompliances OBJECT IDENTIFIER ::= { frsldConformance 2 }
|
|
|
|
--
|
|
-- Compliance Statements
|
|
--
|
|
|
|
frsldCompliance MODULE-COMPLIANCE
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The compliance statement for SNMP entities
|
|
which support with Frame Relay Service Level
|
|
Definitions. This group defines the minimum
|
|
level of support required for compliance."
|
|
MODULE -- this module
|
|
MANDATORY-GROUPS { frsldPvcReqCtrlGroup,
|
|
frsldPvcReqDataGroup,
|
|
frsldCapabilitiesGroup}
|
|
|
|
GROUP frsldPvcHCFrameDataGroup
|
|
DESCRIPTION
|
|
"This group is mandatory only for those network
|
|
interfaces with corresponding instance of ifSpeed
|
|
greater than 650,000,000 bits/second."
|
|
|
|
GROUP frsldPvcHCOctetDataGroup
|
|
DESCRIPTION
|
|
"This group is mandatory only for those network
|
|
interfaces with corresponding instance of ifSpeed
|
|
greater than 650,000,000 bits/second."
|
|
|
|
GROUP frsldPvcPacketGroup
|
|
DESCRIPTION
|
|
"This group is optional. Network interfaces that
|
|
allow control of the packets used to collect
|
|
information are encouraged to implement this
|
|
group."
|
|
|
|
GROUP frsldPvcDelayCtrlGroup
|
|
DESCRIPTION
|
|
"This group is optional. Network interfaces that
|
|
offer control of the delay measurement are
|
|
strongly encouraged to implement this group."
|
|
|
|
GROUP frsldPvcSampleCtrlGroup
|
|
DESCRIPTION
|
|
"This group is mandatory only for those network
|
|
|
|
interfaces that allow data sampling."
|
|
|
|
GROUP frsldPvcDelayDataGroup
|
|
DESCRIPTION
|
|
"This group is only mandatory when
|
|
frsldPvcDelayCtrlGroup is implemented. It is
|
|
strongly encouraged that any device capable
|
|
of measuring delay implement this group."
|
|
|
|
GROUP frsldPvcSampleDelayGroup
|
|
DESCRIPTION
|
|
"This group is only mandatory when both
|
|
frsldPvcSampleCtrlGroup and frsldPvcDelayDataGroup
|
|
are supported."
|
|
|
|
GROUP frsldPvcSampleDataGroup
|
|
DESCRIPTION
|
|
"This group is mandatory whenever
|
|
frsldPvcSampleCtrlGroup is supported."
|
|
|
|
GROUP frsldPvcSampleHCFrameGroup
|
|
DESCRIPTION
|
|
"This group is mandatory whenever both
|
|
frsldPvcSampleCtrlGroup and frsldPvcHCFrameDataGroup
|
|
are supported."
|
|
|
|
GROUP frsldPvcSampleHCDataGroup
|
|
DESCRIPTION
|
|
"This group is mandatory whenever both
|
|
frsldPvcSampleCtrlGroup and frsldPvcHCOctetDataGroup
|
|
are supported."
|
|
|
|
GROUP frsldPvcSampleAvailGroup
|
|
DESCRIPTION
|
|
"This group is mandatory whenever
|
|
frsldPvcSampleCtrlGroup is supported."
|
|
|
|
GROUP frsldPvcSampleGeneralGroup
|
|
DESCRIPTION
|
|
"This group is mandatory whenever
|
|
frsldPvcSampleCtrlGroup is supported."
|
|
|
|
OBJECT frsldPvcCtrlStatus
|
|
SYNTAX RowStatus { active(1) } -- subset of RowStatus
|
|
MIN-ACCESS read-only
|
|
DESCRIPTION
|
|
"Row creation can be done outside of the scope of
|
|
the SNMP protocol. If this object is implemented
|
|
|
|
with max-access of read-only, then the only value
|
|
that MUST be returned is active(1) and
|
|
frsldPvcCtrlWriteCaps MUST return 0 for the
|
|
frsldPvcCtrlStatus(0) bit."
|
|
|
|
OBJECT frsldPvcCtrlPurge
|
|
MIN-ACCESS read-only
|
|
DESCRIPTION
|
|
"Write access is not required. If this object is
|
|
implemented with a max-access of read-only, then
|
|
the frsldPvcCtrlPurge(5) bit must return 0."
|
|
|
|
OBJECT frsldPvcCtrlDeleteOnPurge
|
|
MIN-ACCESS read-only
|
|
DESCRIPTION
|
|
"Write access is not required. If this object is
|
|
implemented with a max-access of read-only, then
|
|
the frsldPvcCtrlDeleteOnPurge(6) bit must return
|
|
0."
|
|
|
|
OBJECT frsldMaxPvcCtrls
|
|
MIN-ACCESS read-only
|
|
DESCRIPTION
|
|
"Write access is not required if the device either
|
|
dynamically allocates memory or statically allocates
|
|
a fixed number of entries. In the case of static
|
|
allocation, the device should always report the
|
|
correct maximum number of controls. In the case
|
|
of dynamic allocation, the device SHOULD always
|
|
report a number greater than frsldNumPvcCtrls
|
|
when allocation is possible and a number equal to
|
|
frsldNumPvcCtrls when allocation is not possible."
|
|
OBJECT frsldMaxSmplCtrls
|
|
MIN-ACCESS read-only
|
|
DESCRIPTION
|
|
"Write access is not required if the device either
|
|
dynamically allocates memory or statically allocates
|
|
a fixed number of entries. In the case of static
|
|
allocation, the device should always report the
|
|
correct maximum number of controls. In the case
|
|
of dynamic allocation, the device SHOULD always
|
|
report a number greater than frsldNumSmplCtrls
|
|
when allocation is possible and a number equal to
|
|
frsldNumSmplCtrls when allocation is not possible."
|
|
::= { frsldMIBCompliances 1 }
|
|
|
|
--
|
|
|
|
-- Units of Conformance
|
|
--
|
|
frsldPvcReqCtrlGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
frsldPvcCtrlStatus,
|
|
frsldPvcCtrlPurge,
|
|
frsldPvcCtrlDeleteOnPurge,
|
|
frsldPvcCtrlLastPurgeTime
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A collection of required objects providing
|
|
control information applicable to a PVC which
|
|
implements Service Level Definitions."
|
|
::= { frsldMIBGroups 1 }
|
|
|
|
frsldPvcPacketGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
frsldPvcCtrlPacketFreq
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A collection of optional objects providing packet
|
|
level control information applicable to a PVC which
|
|
implements Service Level Definitions."
|
|
::= { frsldMIBGroups 2 }
|
|
|
|
frsldPvcDelayCtrlGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
frsldPvcCtrlDelayFrSize,
|
|
frsldPvcCtrlDelayType,
|
|
frsldPvcCtrlDelayTimeOut
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A collection of optional objects providing delay
|
|
control information applicable to a PVC which
|
|
implements Service Level Definitions.
|
|
|
|
If this group is implemented, frsldPvcPacketGroup
|
|
and frsldPvcDelayDataGroup MUST also be implemented."
|
|
::= { frsldMIBGroups 3 }
|
|
|
|
frsldPvcSampleCtrlGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
frsldSmplCtrlStatus,
|
|
frsldSmplCtrlColPeriod,
|
|
frsldSmplCtrlBuckets,
|
|
frsldSmplCtrlBucketsGranted
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A collection of optional objects providing sample
|
|
control information applicable to a PVC which
|
|
implements Service Level Definitions.
|
|
|
|
If this group is implemented, frsldPvcReqDataGroup
|
|
and frsldPvcSampleGeneralGroup MUST also be
|
|
implemented."
|
|
::= { frsldMIBGroups 4 }
|
|
|
|
frsldPvcReqDataGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
frsldPvcDataFrDeliveredC,
|
|
frsldPvcDataFrDeliveredE,
|
|
frsldPvcDataFrOfferedC,
|
|
frsldPvcDataFrOfferedE,
|
|
frsldPvcDataDataDeliveredC,
|
|
frsldPvcDataDataDeliveredE,
|
|
frsldPvcDataDataOfferedC,
|
|
frsldPvcDataDataOfferedE,
|
|
frsldPvcDataUnavailableTime,
|
|
frsldPvcDataUnavailables
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A collection of required objects providing data
|
|
collected on a PVC which implements Service
|
|
Level Definitions."
|
|
::= { frsldMIBGroups 5 }
|
|
|
|
frsldPvcDelayDataGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
frsldPvcDataMissedPolls
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A collection of optional objects providing delay
|
|
data collected on a PVC which implements Service
|
|
Level Definitions.
|
|
|
|
If this group is implemented, frsldPvcDelayCtrlGroup
|
|
MUST also be implemented."
|
|
::= { frsldMIBGroups 6 }
|
|
|
|
frsldPvcHCFrameDataGroup OBJECT-GROUP
|
|
|
|
OBJECTS {
|
|
frsldPvcDataHCFrDeliveredC,
|
|
frsldPvcDataHCFrDeliveredE,
|
|
frsldPvcDataHCFrOfferedC,
|
|
frsldPvcDataHCFrOfferedE
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A collection of optional objects providing high
|
|
capacity frame data collected on a PVC which
|
|
implements Service Level Definitions."
|
|
::= { frsldMIBGroups 7 }
|
|
|
|
frsldPvcHCOctetDataGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
frsldPvcDataHCDataDeliveredC,
|
|
frsldPvcDataHCDataDeliveredE,
|
|
frsldPvcDataHCDataOfferedC,
|
|
frsldPvcDataHCDataOfferedE
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A collection of optional objects providing high
|
|
capacity octet data collected on a PVC which
|
|
implements Service Level Definitions."
|
|
::= { frsldMIBGroups 8 }
|
|
|
|
frsldPvcSampleDelayGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
frsldPvcSmplDelayMin,
|
|
frsldPvcSmplDelayMax,
|
|
frsldPvcSmplDelayAvg,
|
|
frsldPvcSmplMissedPolls
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A collection of optional objects providing delay
|
|
sample data collected on a PVC which implements
|
|
Service Level Definitions.
|
|
|
|
If this group is implemented, frsldPvcDelayCtrlGroup
|
|
MUST also be implemented."
|
|
::= { frsldMIBGroups 9 }
|
|
|
|
frsldPvcSampleDataGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
frsldPvcSmplFrDeliveredC,
|
|
frsldPvcSmplFrDeliveredE,
|
|
frsldPvcSmplFrOfferedC,
|
|
frsldPvcSmplFrOfferedE,
|
|
frsldPvcSmplDataDeliveredC,
|
|
frsldPvcSmplDataDeliveredE,
|
|
frsldPvcSmplDataOfferedC,
|
|
frsldPvcSmplDataOfferedE
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A collection of optional objects providing data
|
|
and frame delivery sample data collected on a PVC
|
|
which implements Service Level Definitions.
|
|
|
|
If this group is implemented, frsldPvcReqDataGroup
|
|
MUST also be implemented."
|
|
::= { frsldMIBGroups 10 }
|
|
|
|
frsldPvcSampleHCFrameGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
frsldPvcSmplHCFrDeliveredC,
|
|
frsldPvcSmplHCFrDeliveredE,
|
|
frsldPvcSmplHCFrOfferedC,
|
|
frsldPvcSmplHCFrOfferedE
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A collection of optional objects providing high
|
|
capacity frame delivery sample data collected on a PVC
|
|
which implements Service Level Definitions.
|
|
|
|
If this group is implemented, frsldPvcHCFrameDataGroup
|
|
MUST also be implemented."
|
|
::= { frsldMIBGroups 11 }
|
|
|
|
frsldPvcSampleHCDataGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
frsldPvcSmplHCDataDeliveredC,
|
|
frsldPvcSmplHCDataDeliveredE,
|
|
frsldPvcSmplHCDataOfferedC,
|
|
frsldPvcSmplHCDataOfferedE
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A collection of optional objects providing high
|
|
capacity data delivery sample data collected on a PVC
|
|
which implements Service Level Definitions.
|
|
|
|
If this group is implemented, frsldPvcHCOctetDataGroup
|
|
|
|
MUST also be implemented."
|
|
::= { frsldMIBGroups 12 }
|
|
|
|
frsldPvcSampleAvailGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
frsldPvcSmplUnavailableTime,
|
|
frsldPvcSmplUnavailables
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A collection of optional objects providing
|
|
availability sample data collected on a PVC which
|
|
implements Service Level Definitions.
|
|
|
|
If this group is implemented, frsldPvcReqDataGroup
|
|
MUST also be implemented."
|
|
::= { frsldMIBGroups 13 }
|
|
|
|
frsldPvcSampleGeneralGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
frsldPvcSmplStartTime,
|
|
frsldPvcSmplEndTime
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A collection of optional objects providing
|
|
general sample data collected on a PVC which
|
|
implements Service Level Definitions."
|
|
::= { frsldMIBGroups 14 }
|
|
|
|
frsldCapabilitiesGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
frsldPvcCtrlWriteCaps,
|
|
frsldSmplCtrlWriteCaps,
|
|
frsldRPCaps,
|
|
frsldMaxPvcCtrls,
|
|
frsldNumPvcCtrls,
|
|
frsldMaxSmplCtrls,
|
|
frsldNumSmplCtrls
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A collection of required objects providing
|
|
capability information and control for this
|
|
MIB module."
|
|
::= { frsldMIBGroups 15 }
|
|
END
|