Observium_CE/mibs/raisecom/SWITCH-CLKMGMT-MIB

104 lines
3.2 KiB
Plaintext

--MibName=raisecomClkmgmt
-- *****************************************************************
-- Version 1.0 Created 2010.10.14 by zengliang
-- This version of MIB is created just for the Management of ES-SUB-CLK.
--
-- Copyright(c) 2002-2012 by RAISECOM TECH, Ltd.
-- All rights reserved.
--
-- modify history
--
-- *****************************************************************
SWITCH-CLKMGMT-MIB DEFINITIONS ::= BEGIN
IMPORTS
raisecomAgent
FROM RAISECOM-BASE-MIB
EnableVar
FROM SWITCH-TC
Integer32, Unsigned32,IpAddress
FROM SNMPv2-SMI;
raisecomClkmgmt MODULE-IDENTITY
LAST-UPDATED "201010140000Z"
ORGANIZATION "Raisecom, Inc."
CONTACT-INFO
" Raise Systems
Postal: Beijing,
China
Tel: 86-010-82884499
E-mail: support@raisecom.com"
DESCRIPTION
"Configuration of clkmgmt object."
-- -------------------------------------------------------------
-- modify history
-- -------------------------------------------------------------
REVISION "201010140000Z"
DESCRIPTION "The initial revision of this MIB."
::= { raisecomAgent 21}
-- -------------------------------------------------------------
-- groups in the SWITCH-CLKMGMT MIB
-- -------------------------------------------------------------
-- -------------------------------------------------------------
-- raisecomClkmgmt2mPortTable
-- -------------------------------------------------------------
raisecomClkmgmt2mPortTable OBJECT-TYPE
SYNTAX SEQUENCE OF raisecomClkmgmt2mPortEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Clock-management 2m port table."
::= { raisecomClkmgmt 1 }
raisecomClkmgmt2mPortEntry OBJECT-TYPE
SYNTAX raisecomClkmgmt2mPortEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Clock-management 2m port table entry."
INDEX { raisecomClkmgmt2mPortIndex }
::= { raisecomClkmgmt2mPortTable 1 }
raisecomClkmgmt2mPortEntry ::= SEQUENCE {
raisecomClkmgmt2mPortIndex Unsigned32,
raisecomClkmgmt2mPortMode INTEGER,
raisecomClkmgmt2mPortE1SaBit INTEGER,
}
raisecomClkmgmt2mPortIndex OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Clock management 2m port index."
::= { raisecomClkmgmt2mPortEntry 1 }
raisecomClkmgmt2mPortMode OBJECT-TYPE
SYNTAX INTEGER
{
clk-2mHz(1),
clk-E1(2),
clk-E1-CRC(3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Mode of 2m port."
::= { raisecomClkmgmt2mPortEntry 2 }
raisecomClkmgmt2mPortE1SaBit OBJECT-TYPE
SYNTAX INTEGER(4..8)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Sa bit"
::= { raisecomClkmgmt2mPortEntry 3 }
END