974 lines
24 KiB
Plaintext
974 lines
24 KiB
Plaintext
-- =======================================================================
|
||
-- RAISECOM-OPTICAL-UDSFP-INTERFACE-MIB.my
|
||
--
|
||
-- Version info
|
||
--
|
||
-- Copyright(c) 2003-2005 by RAISECOM TECH, Ltd.
|
||
-- All rights reserved.
|
||
-- =======================================================================
|
||
|
||
|
||
RAISECOM-OPTICAL-UDSFP-INTERFACE-MIB DEFINITIONS ::= BEGIN
|
||
|
||
IMPORTS
|
||
MODULE-IDENTITY, OBJECT-TYPE, NOTIFICATION-TYPE, Integer32
|
||
FROM SNMPv2-SMI
|
||
TEXTUAL-CONVENTION, DisplayString, TruthValue, TimeStamp
|
||
FROM SNMPv2-TC
|
||
ifIndex
|
||
FROM IF-MIB
|
||
optUdSysMgmt
|
||
FROM RAISECOM-BASE-MIB
|
||
-- RcOptModuleType, RcOptIfModuleType
|
||
-- FROM RAISECOM-OPTICAL-MODULE-TYPE-MIB
|
||
rcNotifsTrapLocation
|
||
FROM RAISECOM-NOTIFICATION-MIB
|
||
rcEntPhysicalID
|
||
FROM RAISECOM-OPTICAL-ENTITY-MIB;
|
||
|
||
raisecomOptUdSfpInterfaceMib MODULE-IDENTITY
|
||
|
||
LAST-UPDATED "201206270000Z"
|
||
ORGANIZATION "OPCOM3500 Software Working Group"
|
||
CONTACT-INFO
|
||
" "
|
||
DESCRIPTION
|
||
"The MIB module to describe Sfp interface objects."
|
||
REVISION "0711290000Z"
|
||
DESCRIPTION
|
||
"
|
||
初始版本,由RAISECOM-OPTICAL-SFP-INTERFACE-MIB.my修改得来
|
||
增加rcEntPhysicalID作为索引
|
||
"
|
||
REVISION "0808110000Z"
|
||
DESCRIPTION
|
||
"
|
||
1、增加了数字诊断DDM表;
|
||
2、rcOptUdSfpOpticalInterface节点增加了枚举值
|
||
"
|
||
REVISION "1003030000Z"
|
||
DESCRIPTION
|
||
"
|
||
1、增加了当前15分钟数字诊断CurrentDDM表;
|
||
2、增加了96个15分钟数字诊断IntervalDDM表;
|
||
3、增加数字诊断告警10对;
|
||
4、修改编译错误;
|
||
by wuyanxiong
|
||
"
|
||
REVISION "1005070000Z"
|
||
DESCRIPTION
|
||
"
|
||
1、增加了rcOptUdSfpMediaType的fiber50uOM3(6)枚举值,from sfpif;
|
||
--by huxuehai
|
||
"
|
||
REVISION "201108110000Z"
|
||
DESCRIPTION
|
||
"
|
||
1、 修改rcOptUdSfpPortStatus bit表示范围为(1..4095),支持激光器背光功率告警
|
||
和激光器寿命告警,与sfp同步;
|
||
by yanghui
|
||
"
|
||
|
||
REVISION "201206270000Z"
|
||
DESCRIPTION
|
||
"
|
||
1、新增一个节点rcOptUdSfpAlsDisable,用来实现ALS功能
|
||
by yangchengming
|
||
"
|
||
|
||
::= { optUdSysMgmt 21 }
|
||
|
||
|
||
|
||
--对象定义
|
||
rcOptUdSfpInterfaceObjects OBJECT IDENTIFIER ::= { raisecomOptUdSfpInterfaceMib 1 }
|
||
rcOptUdSfpNotifications OBJECT IDENTIFIER ::= { raisecomOptUdSfpInterfaceMib 2 }
|
||
|
||
|
||
-- Sfp interface table
|
||
|
||
rcOptUdSfpInterfaceTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF RcOptUdSfpInterfaceEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Sfp接口的信息.
|
||
"
|
||
::= { rcOptUdSfpInterfaceObjects 1 }
|
||
|
||
rcOptUdSfpInterfaceEntry OBJECT-TYPE
|
||
SYNTAX RcOptUdSfpInterfaceEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
"
|
||
INDEX {rcEntPhysicalID, ifIndex }
|
||
::= { rcOptUdSfpInterfaceTable 1 }
|
||
|
||
RcOptUdSfpInterfaceEntry ::= SEQUENCE {
|
||
rcOptUdSfpInterfaceId
|
||
INTEGER,
|
||
rcOptUdSfpExist
|
||
INTEGER,
|
||
rcOptUdSfpMediaType
|
||
INTEGER,
|
||
rcOptUdSfpRXLOS
|
||
INTEGER,
|
||
rcOptUdSfpTXFault
|
||
INTEGER,
|
||
rcOptUdSfpTXDisable
|
||
INTEGER,
|
||
rcOptUdSfpModuleType
|
||
INTEGER,
|
||
rcOptUdSfpOpticalInterface
|
||
INTEGER,
|
||
rcOptUdSfpSpeedStatus
|
||
INTEGER,
|
||
rcOptUdSfpTransportDistance
|
||
INTEGER,
|
||
rcOptUdSfpWaveLength
|
||
Integer32,
|
||
rcOptUdSfpManufactory
|
||
OCTET STRING,
|
||
rcOptUdSfpProductType
|
||
OCTET STRING,
|
||
rcOptUdSfpVersion
|
||
OCTET STRING,
|
||
rcOptUdSfpWaterMask
|
||
OCTET STRING,
|
||
rcOptUdSfpAlsDisable
|
||
INTEGER
|
||
}
|
||
|
||
rcOptUdSfpInterfaceId OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
端口ID, 第一个端口Id为1,依次类推
|
||
"
|
||
::={ rcOptUdSfpInterfaceEntry 1 }
|
||
|
||
|
||
rcOptUdSfpExist OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
exist(1),
|
||
notExist(2)
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
模块在位通知
|
||
"
|
||
::= { rcOptUdSfpInterfaceEntry 3 }
|
||
|
||
|
||
rcOptUdSfpMediaType OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
unknown(1),
|
||
fiber9u125u(2),
|
||
fiber50u125u(3),
|
||
fiber625u125u(4),
|
||
copper(5),
|
||
fiber50uOM3(6)
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
介质类型
|
||
"
|
||
::={ rcOptUdSfpInterfaceEntry 4 }
|
||
|
||
|
||
rcOptUdSfpRXLOS OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
normal(1),
|
||
alarm(2)
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
光模块LOS状态
|
||
"
|
||
::= { rcOptUdSfpInterfaceEntry 5 }
|
||
|
||
rcOptUdSfpTXFault OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
normal(1),
|
||
alarm(2)
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
激光器发送故障
|
||
"
|
||
::= { rcOptUdSfpInterfaceEntry 6 }
|
||
|
||
rcOptUdSfpTXDisable OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
enable(1),
|
||
disable(2)
|
||
}
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
光信号发送禁止.即关闭光口
|
||
"
|
||
::= { rcOptUdSfpInterfaceEntry 7 }
|
||
|
||
|
||
|
||
|
||
rcOptUdSfpModuleType OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
unknown(1),
|
||
gbic(2),
|
||
sff(3),
|
||
sfp(4)
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
模块类型
|
||
"
|
||
::= { rcOptUdSfpInterfaceEntry 9 }
|
||
|
||
|
||
rcOptUdSfpOpticalInterface OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
unknown(1),
|
||
sc(2),
|
||
lc(3),
|
||
rj45(4),
|
||
fiber-channel-style1-copper-connector(5),
|
||
fiber-channel-style2-copper-connector(6),
|
||
bnc-tnc(7),
|
||
fiber-channel-coaxial-headers(8),
|
||
fiber-jack(9),
|
||
mt-rj(10),
|
||
mu(11),
|
||
sg(12),
|
||
optical-pigtail(13),
|
||
hssdc-ii(22),
|
||
copper-pigtail(23)
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
光连接头形式
|
||
"
|
||
::= { rcOptUdSfpInterfaceEntry 10 }
|
||
|
||
rcOptUdSfpSpeedStatus OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
unknown(1),
|
||
speed125M(2),
|
||
speed155M(3),
|
||
speed1250M(4),
|
||
speed2500M(5),
|
||
speed622M(6)
|
||
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
额定速率
|
||
"
|
||
::= { rcOptUdSfpInterfaceEntry 11 }
|
||
|
||
rcOptUdSfpTransportDistance OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
传输距离.单位根据传输介质判断,对应关系如下 :
|
||
fiber9u125u(2)--单位 Km
|
||
fiber50u125u(3)--单位 10m
|
||
fiber625u125u(4)--单位 10m
|
||
copper(5)--单位 m
|
||
|
||
"
|
||
::= { rcOptUdSfpInterfaceEntry 12 }
|
||
|
||
rcOptUdSfpWaveLength OBJECT-TYPE
|
||
SYNTAX Integer32
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
波长.单位nm
|
||
"
|
||
::= { rcOptUdSfpInterfaceEntry 13 }
|
||
|
||
|
||
rcOptUdSfpManufactory OBJECT-TYPE
|
||
SYNTAX OCTET STRING(SIZE (0..16))
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
模块制造厂商
|
||
"
|
||
::= { rcOptUdSfpInterfaceEntry 14 }
|
||
|
||
rcOptUdSfpProductType OBJECT-TYPE
|
||
SYNTAX OCTET STRING(SIZE (0..16))
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
产品型号
|
||
"
|
||
::= { rcOptUdSfpInterfaceEntry 15 }
|
||
|
||
rcOptUdSfpVersion OBJECT-TYPE
|
||
SYNTAX OCTET STRING(SIZE (0..4))
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
模块版本号
|
||
"
|
||
::= { rcOptUdSfpInterfaceEntry 16 }
|
||
|
||
rcOptUdSfpWaterMask OBJECT-TYPE
|
||
SYNTAX OCTET STRING(SIZE (0..16))
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
模块流水号
|
||
"
|
||
::= { rcOptUdSfpInterfaceEntry 17 }
|
||
|
||
rcOptUdSfpAlsDisable OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
enable(1),
|
||
disable(2)
|
||
}
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
激光器自动关断
|
||
"
|
||
::= { rcOptUdSfpInterfaceEntry 18 }
|
||
|
||
-- Sfp interface DDM table
|
||
|
||
rcOptUdSfpDDMTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF RcOptUdSfpDDMEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Sfp接口的信息.
|
||
"
|
||
::= { rcOptUdSfpInterfaceObjects 2 }
|
||
|
||
rcOptUdSfpDDMEntry OBJECT-TYPE
|
||
SYNTAX RcOptUdSfpDDMEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
"
|
||
INDEX { rcEntPhysicalID, ifIndex }
|
||
::= { rcOptUdSfpDDMTable 1 }
|
||
|
||
RcOptUdSfpDDMEntry ::= SEQUENCE {
|
||
rcOptUdSfpPortTemperature
|
||
OCTET STRING,
|
||
rcOptUdSfpSupportDDM
|
||
INTEGER,
|
||
rcOptUdSfpPortVoltage
|
||
OCTET STRING,
|
||
rcOptUdSfpPortBiasCurrent
|
||
OCTET STRING,
|
||
rcOptUdSfpPortTxPower
|
||
OCTET STRING,
|
||
rcOptUdSfpPortRxPower
|
||
OCTET STRING,
|
||
rcOptUdSfpPortStatus
|
||
Integer32,
|
||
rcOptUdSfpPortWarning
|
||
Integer32,
|
||
rcOptUdSfpPortRegulator
|
||
INTEGER
|
||
}
|
||
|
||
rcOptUdSfpSupportDDM OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
support(1),
|
||
notsupport(2)
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
光模块是否支持数字诊断
|
||
"
|
||
::= { rcOptUdSfpDDMEntry 1 }
|
||
|
||
rcOptUdSfpPortTemperature OBJECT-TYPE
|
||
SYNTAX OCTET STRING(SIZE (0..16))
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
光模块温度 -128℃ ~ +128℃
|
||
"
|
||
::= { rcOptUdSfpDDMEntry 2 }
|
||
|
||
rcOptUdSfpPortVoltage OBJECT-TYPE
|
||
SYNTAX OCTET STRING(SIZE (0..16))
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
光模块电压 0 ~ 6.55V
|
||
"
|
||
::= { rcOptUdSfpDDMEntry 3 }
|
||
|
||
rcOptUdSfpPortBiasCurrent OBJECT-TYPE
|
||
SYNTAX OCTET STRING(SIZE (0..16))
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
光模块偏置电流 0 ~ 131mA
|
||
"
|
||
::= { rcOptUdSfpDDMEntry 4 }
|
||
|
||
rcOptUdSfpPortTxPower OBJECT-TYPE
|
||
SYNTAX OCTET STRING(SIZE (0..16))
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
光模块发送光功率 0 ~ 6.5535mW
|
||
"
|
||
::= { rcOptUdSfpDDMEntry 5 }
|
||
|
||
rcOptUdSfpPortRxPower OBJECT-TYPE
|
||
SYNTAX OCTET STRING(SIZE (0..16))
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
光模块接收光功率 0 ~ 6.5535mW
|
||
"
|
||
::= { rcOptUdSfpDDMEntry 6 }
|
||
|
||
rcOptUdSfpPortStatus OBJECT-TYPE
|
||
SYNTAX Integer32 (1..4095)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
模块性能超限警告,即alarm状态,bitmap表示,每个bit对应告警状态如下:
|
||
1 rcOptUdSfpTemperatureHighThreshold
|
||
2 rcOptUdSfpTemperatureLowThreshold
|
||
4 rcOptUdSfpVoltageHighThreshold
|
||
8 rcOptUdSfpVoltageLowThreshold
|
||
16 rcOptUdSfpBiasCurrentHighThreshold
|
||
32 rcOptUdSfpBiasCurrentLowThreshold
|
||
64 rcOptUdSfpTxPowerHighThreshold
|
||
128 rcOptUdSfpTxPowerLowThreshold
|
||
256 rcOptUdSfpRxPowerHighThreshold
|
||
512 rcOptUdSfpRxPowerLowThreshold
|
||
1024 rcOptUdSfpLDBackLightAlarm -- 激光器背光功率告警
|
||
2048 rcOptUdSfpLDLifeAlarm -- 激光器寿命告警
|
||
"
|
||
::= { rcOptUdSfpDDMEntry 7 }
|
||
|
||
rcOptUdSfpPortWarning OBJECT-TYPE
|
||
SYNTAX Integer32 (1..1023)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
模块性能超限告警,即warning状态,比alarm的告警级别低,
|
||
bitmap表示,每个bit对应告警状态如下:
|
||
1 rcOptUdSfpTemperatureHighThreshold
|
||
2 rcOptUdSfpTemperatureLowThreshold
|
||
4 rcOptUdSfpVoltageHighThreshold
|
||
8 rcOptUdSfpVoltageLowThreshold
|
||
16 rcOptUdSfpBiasCurrentHighThreshold
|
||
32 rcOptUdSfpBiasCurrentLowThreshold
|
||
64 rcOptUdSfpTxPowerHighThreshold
|
||
128 rcOptUdSfpTxPowerLowThreshold
|
||
256 rcOptUdSfpRxPowerHighThreshold
|
||
512 rcOptUdSfpRxPowerLowThreshold
|
||
"
|
||
::= { rcOptUdSfpDDMEntry 8 }
|
||
rcOptUdSfpPortRegulator OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
internally(1),
|
||
externally(0),
|
||
unknown(2)
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
" "
|
||
::= { rcOptUdSfpDDMEntry 9 }
|
||
|
||
|
||
-- 告警信息定义
|
||
|
||
rcOptUdSfpNotificationPrefix OBJECT IDENTIFIER ::= { rcOptUdSfpNotifications 0 }
|
||
|
||
rcOptUdSfpNotExistTrap NOTIFICATION-TYPE
|
||
OBJECTS { rcNotifsTrapLocation, rcEntPhysicalID, ifIndex }
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Sfp不在位通知信号.
|
||
"
|
||
::= { rcOptUdSfpNotificationPrefix 102301 }
|
||
|
||
rcOptUdSfpExistTrap NOTIFICATION-TYPE
|
||
OBJECTS { rcNotifsTrapLocation, rcEntPhysicalID, ifIndex }
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Sfp在位通知信号.
|
||
"
|
||
::= { rcOptUdSfpNotificationPrefix 102302 }
|
||
|
||
rcOptUdSfpTXFaultTrap NOTIFICATION-TYPE
|
||
OBJECTS { rcNotifsTrapLocation, rcEntPhysicalID, ifIndex }
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
激光器发送故障.
|
||
"
|
||
::= { rcOptUdSfpNotificationPrefix 102303 }
|
||
|
||
rcOptUdSfpTXFaultTrapOK NOTIFICATION-TYPE
|
||
OBJECTS { rcNotifsTrapLocation, rcEntPhysicalID, ifIndex }
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
激光器发送故障清除.
|
||
"
|
||
::= { rcOptUdSfpNotificationPrefix 102304 }
|
||
|
||
rcOptUdSfpRXLOSTrap NOTIFICATION-TYPE
|
||
OBJECTS { rcNotifsTrapLocation, rcEntPhysicalID, ifIndex }
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
接收LOS告警.
|
||
"
|
||
::= { rcOptUdSfpNotificationPrefix 102305 }
|
||
|
||
rcOptUdSfpRXLOSTrapOK NOTIFICATION-TYPE
|
||
OBJECTS { rcNotifsTrapLocation, rcEntPhysicalID, ifIndex }
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Sfp接收LOS清除.
|
||
"
|
||
::= { rcOptUdSfpNotificationPrefix 102306 }
|
||
|
||
rcOptUdSfpTempHighTrap NOTIFICATION-TYPE
|
||
OBJECTS { rcNotifsTrapLocation, rcEntPhysicalID, ifIndex }
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
温度超过上限alarm.
|
||
"
|
||
::= { rcOptUdSfpNotificationPrefix 102307 }
|
||
|
||
rcOptUdSfpTempHighTrapOK NOTIFICATION-TYPE
|
||
OBJECTS { rcNotifsTrapLocation, rcEntPhysicalID, ifIndex }
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
温度超过上限alarm恢复.
|
||
"
|
||
::= { rcOptUdSfpNotificationPrefix 102308 }
|
||
|
||
rcOptUdSfpTempLowTrap NOTIFICATION-TYPE
|
||
OBJECTS { rcNotifsTrapLocation, rcEntPhysicalID, ifIndex }
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
温度低于下限alarm
|
||
"
|
||
::= { rcOptUdSfpNotificationPrefix 102309 }
|
||
|
||
rcOptUdSfpTempLowTrapOK NOTIFICATION-TYPE
|
||
OBJECTS { rcNotifsTrapLocation, rcEntPhysicalID, ifIndex }
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
温度低于下限alarm恢复.
|
||
"
|
||
::= { rcOptUdSfpNotificationPrefix 102310 }
|
||
|
||
rcOptUdSfpVccHighTrap NOTIFICATION-TYPE
|
||
OBJECTS { rcNotifsTrapLocation, rcEntPhysicalID, ifIndex }
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
电压超过上限alarm.
|
||
"
|
||
::= { rcOptUdSfpNotificationPrefix 102311 }
|
||
|
||
rcOptUdSfpVccHighTrapOK NOTIFICATION-TYPE
|
||
OBJECTS { rcNotifsTrapLocation, rcEntPhysicalID, ifIndex }
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
电压超过上限alarm恢复.
|
||
"
|
||
::= { rcOptUdSfpNotificationPrefix 102312 }
|
||
|
||
|
||
rcOptUdSfpVccLowTrap NOTIFICATION-TYPE
|
||
OBJECTS { rcNotifsTrapLocation, rcEntPhysicalID, ifIndex }
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
电压低于下限alarm.
|
||
"
|
||
::= { rcOptUdSfpNotificationPrefix 102313 }
|
||
|
||
rcOptUdSfpVccLowTrapOK NOTIFICATION-TYPE
|
||
OBJECTS { rcNotifsTrapLocation, rcEntPhysicalID, ifIndex }
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
电压低于下限alarm恢复.
|
||
"
|
||
::= { rcOptUdSfpNotificationPrefix 102314 }
|
||
|
||
rcOptUdSfpTxBiasHighTrap NOTIFICATION-TYPE
|
||
OBJECTS { rcNotifsTrapLocation, rcEntPhysicalID, ifIndex }
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
电流超过上限alarm.
|
||
"
|
||
::= { rcOptUdSfpNotificationPrefix 102315 }
|
||
|
||
rcOptUdSfpTxBiasHighTrapOK NOTIFICATION-TYPE
|
||
OBJECTS { rcNotifsTrapLocation, rcEntPhysicalID, ifIndex }
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
电流超过上限alarm恢复.
|
||
"
|
||
::= { rcOptUdSfpNotificationPrefix 102316 }
|
||
|
||
rcOptUdSfpTxBiasLowTrap NOTIFICATION-TYPE
|
||
OBJECTS { rcNotifsTrapLocation, rcEntPhysicalID, ifIndex }
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
电流低于下限alarm.
|
||
"
|
||
::= { rcOptUdSfpNotificationPrefix 102317 }
|
||
|
||
rcOptUdSfpTxBiasLowTrapOK NOTIFICATION-TYPE
|
||
OBJECTS { rcNotifsTrapLocation, rcEntPhysicalID, ifIndex }
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
电流低于下限alarm恢复.
|
||
"
|
||
::= { rcOptUdSfpNotificationPrefix 102318 }
|
||
|
||
rcOptUdSfpTxPowerHighTrap NOTIFICATION-TYPE
|
||
OBJECTS { rcNotifsTrapLocation, rcEntPhysicalID, ifIndex }
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
发光功率超过上限alarm.
|
||
"
|
||
::= { rcOptUdSfpNotificationPrefix 102319 }
|
||
|
||
rcOptUdSfpTxPowerHighTrapOK NOTIFICATION-TYPE
|
||
OBJECTS { rcNotifsTrapLocation, rcEntPhysicalID, ifIndex }
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
发光功率超过上限alarm恢复.
|
||
"
|
||
::= { rcOptUdSfpNotificationPrefix 102320 }
|
||
|
||
rcOptUdSfpTxPowerLowTrap NOTIFICATION-TYPE
|
||
OBJECTS { rcNotifsTrapLocation, rcEntPhysicalID, ifIndex }
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
发光功率低于下限alarm.
|
||
"
|
||
::= { rcOptUdSfpNotificationPrefix 102321 }
|
||
|
||
rcOptUdSfpTxPowerLowTrapOK NOTIFICATION-TYPE
|
||
OBJECTS { rcNotifsTrapLocation, rcEntPhysicalID, ifIndex }
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
发光功率低于下限alarm恢复.
|
||
"
|
||
::= { rcOptUdSfpNotificationPrefix 102322 }
|
||
|
||
rcOptUdSfpRxPowerHighTrap NOTIFICATION-TYPE
|
||
OBJECTS { rcNotifsTrapLocation, rcEntPhysicalID, ifIndex }
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
收光功率超过上限alarm.
|
||
"
|
||
::= { rcOptUdSfpNotificationPrefix 102323 }
|
||
|
||
rcOptUdSfpRxPowerHighTrapOK NOTIFICATION-TYPE
|
||
OBJECTS { rcNotifsTrapLocation, rcEntPhysicalID, ifIndex }
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
收光功率超过上限alarm恢复.
|
||
"
|
||
::= { rcOptUdSfpNotificationPrefix 102324 }
|
||
|
||
rcOptUdSfpRxPowerLowTrap NOTIFICATION-TYPE
|
||
OBJECTS { rcNotifsTrapLocation, rcEntPhysicalID, ifIndex }
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
收光功率低于下限alarm.
|
||
"
|
||
::= { rcOptUdSfpNotificationPrefix 102325 }
|
||
|
||
rcOptUdSfpRxPowerLowTrapOK NOTIFICATION-TYPE
|
||
OBJECTS { rcNotifsTrapLocation, rcEntPhysicalID, ifIndex }
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
收光功率低于下限alarm恢复.
|
||
"
|
||
::= { rcOptUdSfpNotificationPrefix 102326 }
|
||
|
||
|
||
-- Sfp interface Current DDM table
|
||
|
||
rcOptUdSfpCurrentDDMTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF rcOptUdSfpCurrentDDMEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Sfp当前15分钟数字诊断信息.
|
||
"
|
||
::= { rcOptUdSfpInterfaceObjects 3 }
|
||
|
||
rcOptUdSfpCurrentDDMEntry OBJECT-TYPE
|
||
SYNTAX rcOptUdSfpCurrentDDMEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
"
|
||
INDEX { rcEntPhysicalID, ifIndex }
|
||
::= { rcOptUdSfpCurrentDDMTable 1 }
|
||
|
||
rcOptUdSfpCurrentDDMEntry ::= SEQUENCE {
|
||
rcOptUdSfpPortCurrentTemperature
|
||
OCTET STRING,
|
||
rcOptUdSfpPortCurrentVoltage
|
||
OCTET STRING,
|
||
rcOptUdSfpPortCurrentBiasCurrent
|
||
OCTET STRING,
|
||
rcOptUdSfpPortCurrentTxPower
|
||
OCTET STRING,
|
||
rcOptUdSfpPortCurrentRxPower
|
||
OCTET STRING
|
||
|
||
}
|
||
|
||
rcOptUdSfpPortCurrentTemperature OBJECT-TYPE
|
||
SYNTAX OCTET STRING(SIZE (0..16))
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
当前15分钟内光模块温度 -128℃ ~ +128℃
|
||
"
|
||
::= { rcOptUdSfpCurrentDDMEntry 1 }
|
||
|
||
rcOptUdSfpPortCurrentVoltage OBJECT-TYPE
|
||
SYNTAX OCTET STRING(SIZE (0..16))
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
当前15分钟内光模块电压 0 ~ 6.55V
|
||
"
|
||
::= { rcOptUdSfpCurrentDDMEntry 2 }
|
||
|
||
rcOptUdSfpPortCurrentBiasCurrent OBJECT-TYPE
|
||
SYNTAX OCTET STRING(SIZE (0..16))
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
当前15分钟内光模块偏置电流 0 ~ 131mA
|
||
"
|
||
::= { rcOptUdSfpCurrentDDMEntry 3 }
|
||
|
||
rcOptUdSfpPortCurrentTxPower OBJECT-TYPE
|
||
SYNTAX OCTET STRING(SIZE (0..16))
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
当前15分钟内光模块发送光功率 0 ~ 6.5535mW
|
||
"
|
||
::= { rcOptUdSfpCurrentDDMEntry 4 }
|
||
|
||
rcOptUdSfpPortCurrentRxPower OBJECT-TYPE
|
||
SYNTAX OCTET STRING(SIZE (0..16))
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
当前15分钟内光模块接收光功率 0 ~ 6.5535mW
|
||
"
|
||
::= { rcOptUdSfpCurrentDDMEntry 5 }
|
||
|
||
-- Sfp interface 15min *96 DDM table
|
||
|
||
rcOptUdSfpIntervalDDMTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF rcOptUdSfpIntervalDDMEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
sfp diagnoinfo during the interval
|
||
"
|
||
::= { rcOptUdSfpInterfaceObjects 4 }
|
||
|
||
rcOptUdSfpIntervalDDMEntry OBJECT-TYPE
|
||
SYNTAX rcOptUdSfpIntervalDDMEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
"
|
||
INDEX { rcEntPhysicalID, ifIndex, rcOptUdSfpPortIntervalNumber}
|
||
::= { rcOptUdSfpIntervalDDMTable 1 }
|
||
|
||
rcOptUdSfpIntervalDDMEntry ::= SEQUENCE {
|
||
rcOptUdSfpPortIntervalNumber
|
||
INTEGER,
|
||
rcOptUdSfpPortIntervalTemperature
|
||
OCTET STRING,
|
||
rcOptUdSfpPortIntervalVoltage
|
||
OCTET STRING,
|
||
rcOptUdSfpPortIntervalBiasCurrent
|
||
OCTET STRING,
|
||
rcOptUdSfpPortIntervalTxPower
|
||
OCTET STRING,
|
||
rcOptUdSfpPortIntervalRxPower
|
||
OCTET STRING
|
||
|
||
}
|
||
|
||
rcOptUdSfpPortIntervalNumber OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Ud sfp PORT 第几个十五分钟
|
||
"
|
||
::= { rcOptUdSfpIntervalDDMEntry 1 }
|
||
|
||
rcOptUdSfpPortIntervalTemperature OBJECT-TYPE
|
||
SYNTAX OCTET STRING(SIZE (0..16))
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
this OBJECT indicates the average temperature in the interval 15 minute interval.
|
||
-128℃ ~ +128℃
|
||
"
|
||
::= { rcOptUdSfpIntervalDDMEntry 2 }
|
||
|
||
rcOptUdSfpPortIntervalVoltage OBJECT-TYPE
|
||
SYNTAX OCTET STRING(SIZE (0..16))
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
This OBJECT indicates the averaget voltage in the interval 15 minute interval.
|
||
0 ~ 6.55V
|
||
"
|
||
::= { rcOptUdSfpIntervalDDMEntry 3 }
|
||
|
||
rcOptUdSfpPortIntervalBiasCurrent OBJECT-TYPE
|
||
SYNTAX OCTET STRING(SIZE (0..16))
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
The object indicates the average offset interval in the interval
|
||
0 ~ 131mA
|
||
"
|
||
::= { rcOptUdSfpIntervalDDMEntry 4 }
|
||
|
||
rcOptUdSfpPortIntervalTxPower OBJECT-TYPE
|
||
SYNTAX OCTET STRING(SIZE (0..16))
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
This object indicates the average receive power in the interval
|
||
0 ~ 6.5535mW
|
||
"
|
||
::= { rcOptUdSfpIntervalDDMEntry 5 }
|
||
|
||
rcOptUdSfpPortIntervalRxPower OBJECT-TYPE
|
||
SYNTAX OCTET STRING(SIZE (0..16))
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
This object indicates the average send power in the interval
|
||
0 ~ 6.5535mW
|
||
"
|
||
::= { rcOptUdSfpIntervalDDMEntry 6 }
|
||
|
||
END
|
||
|
||
|
||
|