--MibName=rcNtp
|
|
-- *****************************************************************
|
|
-- RAISECOM-NTP-MIB.my: NTP MIB
|
|
--
|
|
-- Feb 2009, tangyoucan
|
|
--
|
|
-- Modi Report: 20110811£¬guohuiming, ROS00002217 Abandoned rcNtpSysVersion and add rcNtpPeersVersion
|
|
--
|
|
-- Copyright (c) 1996-2009 by Raisecom Technology Co., Ltd.
|
|
-- All rights reserved.
|
|
--
|
|
-- *****************************************************************
|
|
--
|
|
|
|
RAISECOM-NTP-MIB DEFINITIONS ::= BEGIN
|
|
|
|
IMPORTS
|
|
MODULE-IDENTITY, OBJECT-TYPE, Integer32,
|
|
IpAddress, Gauge32, Unsigned32
|
|
FROM SNMPv2-SMI
|
|
TEXTUAL-CONVENTION, TruthValue, RowStatus
|
|
FROM SNMPv2-TC
|
|
MODULE-COMPLIANCE, OBJECT-GROUP
|
|
FROM SNMPv2-CONF
|
|
iscomSwitch FROM RAISECOM-BASE-MIB;
|
|
|
|
rcNtp MODULE-IDENTITY
|
|
LAST-UPDATED "200902090000Z"
|
|
ORGANIZATION "Raisecom Technology Co., Ltd."
|
|
CONTACT-INFO
|
|
"Raisecom Science & Technology Co., ltd.
|
|
E-mail: support@raisecom.com"
|
|
DESCRIPTION "This MIB module defines a MIB which provides
|
|
mechanisms to monitor an NTP server.
|
|
|
|
The MIB is derived from the Technical Report
|
|
#Management of the NTP with SNMP# TR No. 98-09
|
|
authored by A.S. Sethi and Dave Mills in the
|
|
University of Delaware.
|
|
|
|
Below is a brief overview of NTP system architecture
|
|
and implementation model. This will help understand
|
|
the objects defined below and their relationships.
|
|
|
|
NTP Intro:
|
|
The Network Time Protocol (NTP) Version 3, is used to
|
|
synchronize timekeeping among a set of distributed
|
|
time servers and clients. The service model is based
|
|
on a returnable-time design which depends only on
|
|
measured clock offsets, but does not require reliable
|
|
message delivery. The synchronization subnet uses a
|
|
self-organizing, hierarchical master-slave
|
|
configuration, with synchronization paths determined
|
|
by a minimum-weight spanning tree. While multiple
|
|
masters (primary servers) may exist, there is no
|
|
requirement for an election protocol.
|
|
|
|
System Archiecture:
|
|
In the NTP model a number of primary reference
|
|
sources, synchronized by wire or radio to national
|
|
standards, are connected to widely accessible
|
|
resources, such as backbone gateways, and operated as
|
|
primary time servers. The purpose of NTP is to convey
|
|
timekeeping information from these servers to other
|
|
time servers via the Internet and also to cross-check
|
|
clocks and mitigate errors due to equipment or
|
|
propagation failures. Some number of local-net hosts
|
|
or gateways, acting as secondary time servers, run NTP
|
|
with one or more of the primary servers. In order to
|
|
reduce the protocol overhead, the secondary servers
|
|
distribute time via NTP to the remaining local-net
|
|
hosts. In the interest of reliability, selected hosts
|
|
can be equipped with less accurate but less expensive
|
|
radio clocks and used for backup in case of failure of
|
|
the primary and/or secondary servers or communication
|
|
paths between them.
|
|
|
|
NTP is designed to produce three products: clock
|
|
offset, round-trip delay and dispersion, all of which
|
|
are relative to a selected reference clock. Clock
|
|
offset represents the amount to adjust the local clock
|
|
to bring it into correspondence with the reference
|
|
clock. Roundtrip delay provides the capability to
|
|
launch a message to arrive at the reference clock at a
|
|
specified time. Dispersion represents the maximum
|
|
error of the local clock relative to the reference
|
|
clock. Since most host time servers will synchronize
|
|
via another peer time server, there are two components
|
|
in each of these three products, those determined by
|
|
the peer relative to the primary reference source of
|
|
standard time and those measured by the host relative
|
|
to the peer. Each of these components are maintained
|
|
separately in the protocol in order to facilitate
|
|
error control and management of the subnet itself.
|
|
They provide not only precision measurements of offset
|
|
and delay, but also definitive maximum error bounds,
|
|
so that the user interface can determine not only the
|
|
time, but the quality of the time as well.
|
|
|
|
Implementation Model:
|
|
In what may be the most common client/server model a
|
|
client sends an NTP message to one or more servers and
|
|
processes the replies as received. The server
|
|
interchanges addresses and ports, overwrites certain
|
|
fields in the message, recalculates the checksum and
|
|
returns the message immediately. Information included
|
|
in the NTP message allows the client to determine the
|
|
server time with respect to local time and adjust the
|
|
local clock accordingly. In addition, the message
|
|
includes information to calculate the expected
|
|
timekeeping accuracy and reliability, as well as
|
|
select the best from possibly several servers.
|
|
|
|
While the client/server model may suffice for use on
|
|
local nets involving a public server and perhaps many
|
|
workstation clients, the full generality of NTP
|
|
requires distributed participation of a number of
|
|
client/servers or peers arranged in a dynamically
|
|
reconfigurable, hierarchically distributed
|
|
configuration. It also requires sophisticated
|
|
algorithms for association management, data
|
|
manipulation and local-clock control.
|
|
|
|
Glossary:
|
|
1. Host: Refers to an instantiation of the NTP
|
|
protocol on a local processor.
|
|
2. Peer: Refers to an instantiation of the NTP
|
|
protocol on a remote processor connected by
|
|
a network path from the local host."
|
|
REVISION "200902090000Z"
|
|
DESCRIPTION
|
|
"version 1.0"
|
|
::= { iscomSwitch 44 }
|
|
|
|
--
|
|
-- The various groups defined within this MIB definition:
|
|
--
|
|
|
|
rcNtpMIBObjects OBJECT IDENTIFIER ::= { rcNtp 1 }
|
|
|
|
rcNtpSystem OBJECT IDENTIFIER ::= { rcNtpMIBObjects 1 }
|
|
rcNtpPeers OBJECT IDENTIFIER ::= { rcNtpMIBObjects 2 }
|
|
rcNtpFilter OBJECT IDENTIFIER ::= { rcNtpMIBObjects 3 }
|
|
|
|
--
|
|
-- Textual Conventions
|
|
--
|
|
|
|
NTPTimeStamp ::= TEXTUAL-CONVENTION
|
|
DISPLAY-HINT "4d.4d"
|
|
STATUS current
|
|
DESCRIPTION "NTP timestamps are represented as a 64-bit
|
|
unsigned fixed-point number, in seconds relative to
|
|
00:00 on 1 January 1900. The integer part is in the
|
|
first 32 bits and the fraction part is in the last
|
|
32 bits."
|
|
REFERENCE
|
|
"D.L. Mills, 'Network Time Protocol (Version 3)',
|
|
RFC-1305, March 1992, Section 3.1"
|
|
SYNTAX OCTET STRING (SIZE (8))
|
|
|
|
NTPLeapIndicator ::= TEXTUAL-CONVENTION
|
|
STATUS current
|
|
DESCRIPTION "This is a two-bit code warning of an impending leap
|
|
second to be inserted in the NTP timescale. The bits
|
|
are set before 23:59 on the day of insertion and reset
|
|
after 00:00 on the following day. This causes the
|
|
number of seconds (rollover interval) in the day of
|
|
insertion to be increased or decreased by one. The two
|
|
bits are coded as below,
|
|
00, no warning
|
|
01, last minute has 61 seconds
|
|
10, last minute has 59 seconds
|
|
11, alarm condition (clock not synchronized)"
|
|
REFERENCE
|
|
"D.L. Mills, 'Network Time Protocol(Version 3)',
|
|
RFC-1305, March 1992, Section 3.2.1"
|
|
SYNTAX INTEGER { noWarning(0), addSecond(1),
|
|
subtractSecond(2), alarm(3) }
|
|
|
|
NTPSignedTimeValue ::= TEXTUAL-CONVENTION
|
|
DISPLAY-HINT "2d.2d"
|
|
STATUS current
|
|
DESCRIPTION "The time in seconds that could represent signed
|
|
quantities like time delay with respect to some
|
|
source. This textual-convention is specific to Cisco
|
|
implementation of NTP where 32-bit integers are used
|
|
for such quantities. The signed integer part is in
|
|
the first 16 bits and the fraction part is in the
|
|
last 16 bits."
|
|
REFERENCE
|
|
"D.L. Mills, 'Network Time Protocol (Version 3)',
|
|
RFC-1305, March 1992, Sections 2, 3.2.1"
|
|
SYNTAX OCTET STRING (SIZE (4))
|
|
|
|
NTPUnsignedTimeValue ::= TEXTUAL-CONVENTION
|
|
DISPLAY-HINT "2d.2d"
|
|
STATUS current
|
|
DESCRIPTION "The time in seconds that could represent unsigned
|
|
quantities like maximum error of the local clock
|
|
with respect to some source. This textual-convention
|
|
is specific to Cisco implementation of NTP where
|
|
32-bit integers are used for such quantities. The
|
|
unsigned integer part is in the first 16 bits and the
|
|
fraction part is in the last 16 bits."
|
|
REFERENCE
|
|
"D.L. Mills, 'Network Time Protocol (Version 3)',
|
|
RFC-1305, March 1992, Sections 2, 3.2.1"
|
|
SYNTAX OCTET STRING (SIZE (4))
|
|
|
|
NTPStratum ::= TEXTUAL-CONVENTION
|
|
STATUS current
|
|
DESCRIPTION "Indicates the stratum of the clock. The stratum
|
|
defines the accuracy of a time server. Higher the
|
|
stratum, lower the accuracy.
|
|
0, unspecified
|
|
1, primary reference (e.g., calibrated atomic clock,
|
|
radio clock)
|
|
2-255, secondary reference (via NTP)"
|
|
REFERENCE
|
|
"D.L. Mills, 'Network Time Protocol (Version 3)',
|
|
RFC-1305, March 1992, Section 2.2"
|
|
SYNTAX Integer32 (0..255)
|
|
|
|
NTPRefId ::= TEXTUAL-CONVENTION
|
|
STATUS current
|
|
DESCRIPTION "The reference clock identifier. In the case of
|
|
stratum 0 (unspecified) or stratum 1 (primary
|
|
reference source), this is a four-octet,
|
|
left-justified, zero-padded ASCII string as defined
|
|
in RFC-1305. In the case of stratum 2 and greater
|
|
(secondary reference) this is the four-octet Internet
|
|
address of the peer selected for synchronization.
|
|
|
|
Some examples of stratum 0 identifiers are,
|
|
DCN, DCN routing protocol
|
|
NIST, NIST public modem
|
|
TSP, TSP time protocol
|
|
DTS, Digital Time Service
|
|
|
|
Some examples of stratum 1 identifiers are,
|
|
ATOM, Atomic clock (calibrated)
|
|
VLF, VLF radio (OMEGA,, etc.)
|
|
LORC, LORAN-C radionavigation
|
|
GOES, GOES UHF environment satellite
|
|
GPS, GPS UHF satellite positioning"
|
|
REFERENCE
|
|
"D.L. Mills, Network Time Protocol (Version 3)',
|
|
RFC-1305, March 1992, Section 3.2.1"
|
|
SYNTAX OCTET STRING (SIZE (4))
|
|
|
|
NTPPollInterval ::= TEXTUAL-CONVENTION
|
|
STATUS current
|
|
DESCRIPTION "The minimum interval between transmitted NTP
|
|
messages, in seconds as a power of two. For
|
|
instance, a value of six indicates a minimum
|
|
interval of 64 seconds."
|
|
SYNTAX Integer32 (-20..20)
|
|
|
|
NTPAssocIdentifier ::= TEXTUAL-CONVENTION
|
|
STATUS current
|
|
DESCRIPTION "The association identifier of the peer. Every peer
|
|
with which an NTP server is associated with is
|
|
identified by an association identifier."
|
|
SYNTAX Integer32 (0..2147483647)
|
|
|
|
|
|
--
|
|
-- System Group
|
|
--
|
|
|
|
rcNtpSysLeap OBJECT-TYPE
|
|
SYNTAX NTPLeapIndicator
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Two-bit code warning of an impending leap second to
|
|
be inserted in the NTP timescale. This object can be
|
|
set only when the rcNtpSysStratum has a value of 1."
|
|
::= { rcNtpSystem 1 }
|
|
|
|
rcNtpSysStratum OBJECT-TYPE
|
|
SYNTAX NTPStratum
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "The stratum of the local clock. If the value is set
|
|
to 1, i.e., this is a primary reference, then the
|
|
Primary-Clock procedure described in Section 3.4.6,
|
|
in RFC-1305 is invoked."
|
|
::= { rcNtpSystem 2 }
|
|
|
|
rcNtpSysPrecision OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Signed integer indicating the precision
|
|
of the system clock, in seconds to the nearest
|
|
power of two. The value must be rounded to the
|
|
next larger power of two; for instance, a 50-Hz
|
|
(20 ms) or 60-Hz (16.67 ms) power-frequency clock
|
|
would be assigned the value -5 (31.25 ms), while a
|
|
1000-Hz (1 ms) crystal-controlled clock would be
|
|
assigned the value -9 (1.95 ms)."
|
|
::= { rcNtpSystem 3 }
|
|
|
|
rcNtpSysRootDelay OBJECT-TYPE
|
|
SYNTAX NTPSignedTimeValue
|
|
UNITS "seconds"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "A signed fixed-point number indicating the total
|
|
round-trip delay in seconds, to the primary reference
|
|
source at the root of the synchronization subnet."
|
|
REFERENCE
|
|
"D.L. Mills, 'Network Time Protocol (Version 3)',
|
|
RFC-1305, March 1992, Sections 2.2, 3.2.1"
|
|
::= { rcNtpSystem 4 }
|
|
|
|
rcNtpSysRootDispersion OBJECT-TYPE
|
|
SYNTAX NTPUnsignedTimeValue
|
|
UNITS "seconds"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The maximum error in seconds, relative to the
|
|
primary reference source at the root of the
|
|
synchronization subnet. Only positive values greater
|
|
than zero are possible."
|
|
REFERENCE
|
|
"D.L. Mills, 'Network Time Protocol (Version 3)',
|
|
RFC-1305, March 1992, Sections 2, 2.2, 3.2.1"
|
|
::= { rcNtpSystem 5 }
|
|
|
|
rcNtpSysRefId OBJECT-TYPE
|
|
SYNTAX NTPRefId
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "The reference identifier of the local clock."
|
|
::= { rcNtpSystem 6 }
|
|
|
|
rcNtpSysRefTime OBJECT-TYPE
|
|
SYNTAX NTPTimeStamp
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The local time when the local clock was last
|
|
updated. If the local clock has never been
|
|
synchronized, the value is zero."
|
|
::= { rcNtpSystem 7 }
|
|
|
|
rcNtpSysPoll OBJECT-TYPE
|
|
SYNTAX NTPPollInterval (6..10)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "The interval at which the NTP server polls other NTP
|
|
servers to synchronize its clock."
|
|
::= { rcNtpSystem 8 }
|
|
|
|
rcNtpSysPeer OBJECT-TYPE
|
|
SYNTAX NTPAssocIdentifier
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The current synchronization source. This will
|
|
contain the unique association identifier
|
|
rcNtpPeersAssocId of the corresponding peer entry in
|
|
the rcNtpPeersVarTable of the peer acting as the
|
|
synchronization source. If there is no peer, the
|
|
value will be 0."
|
|
::= { rcNtpSystem 9 }
|
|
|
|
rcNtpSysClock OBJECT-TYPE
|
|
SYNTAX NTPTimeStamp
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The current local time. Local time is derived from
|
|
the hardware clock of the particular machine and
|
|
increments at intervals depending on the design used."
|
|
::= { rcNtpSystem 10 }
|
|
|
|
rcNtpSysClockStatus OBJECT-TYPE
|
|
SYNTAX INTEGER{setByNone(1), setByManual(2),setByTimeProtocol(3)}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Status or local clock,
|
|
setByNone: no set or unsynchronized,
|
|
setByManual: set by cmd or SNMP or other method,
|
|
setByTimeProtocol: set by time protocol"
|
|
DEFVAL { set-by-none }
|
|
::= { rcNtpSystem 11 }
|
|
|
|
rcNtpSysVersion OBJECT-TYPE
|
|
SYNTAX INTEGER{v1(1), v2(2),v3(3)}
|
|
MAX-ACCESS read-write
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"Version of ntp,
|
|
v1: version 1,
|
|
v2: version 2,
|
|
v3: version 3."
|
|
DEFVAL { v3 }
|
|
::= { rcNtpSystem 12 }
|
|
|
|
|
|
rcNtpSysMode OBJECT-TYPE
|
|
SYNTAX INTEGER { ntpMaster(1),ntpSlave(2)}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "The mode of host, with values coded as follows,
|
|
1, ntpMaster,switch as the NTP reference clock;
|
|
2, ntpSlave,switch as the NTP slave clock."
|
|
::= { rcNtpSystem 13 }
|
|
|
|
|
|
rcNtpSysValidServicerIndex OBJECT-TYPE
|
|
SYNTAX Integer32 (0..100)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Find the next valid servicer clock index"
|
|
::= { rcNtpSystem 14 }
|
|
--
|
|
-- Peers Group
|
|
--
|
|
|
|
--
|
|
-- Peer Variables Table
|
|
--
|
|
|
|
rcNtpPeersVarTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF RcNtpPeersVarEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "This table provides information on the peers with
|
|
which the local NTP server has associations. The
|
|
peers are also NTP servers but running on different
|
|
hosts."
|
|
::= { rcNtpPeers 1 }
|
|
|
|
rcNtpPeersVarEntry OBJECT-TYPE
|
|
SYNTAX RcNtpPeersVarEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "Each peers' entry provides NTP information retrieved
|
|
from a particular peer NTP server. Each peer is
|
|
identified by a unique association identifier.
|
|
|
|
Entries are automatically created when the user
|
|
configures the NTP server to be associated with remote
|
|
peers. Similarly entries are deleted when the user
|
|
removes the peer association from the NTP server.
|
|
|
|
Entries can also be created by the management station
|
|
by setting values for the following objects:
|
|
rcNtpPeersPeerAddress, rcNtpPeersHostAddress and
|
|
rcNtpPeersMode and making the rcNtpPeersEntryStatus as
|
|
active(1). At the least, the management station has
|
|
to set a value for rcNtpPeersPeerAddress to make the
|
|
row active."
|
|
INDEX { rcNtpPeersAssocId }
|
|
::= { rcNtpPeersVarTable 1 }
|
|
|
|
RcNtpPeersVarEntry ::= SEQUENCE {
|
|
rcNtpPeersAssocId NTPAssocIdentifier,
|
|
rcNtpPeersConfigured TruthValue,
|
|
rcNtpPeersPeerAddress IpAddress,
|
|
rcNtpPeersPeerPort Integer32,
|
|
rcNtpPeersHostAddress IpAddress,
|
|
rcNtpPeersHostPort Integer32,
|
|
rcNtpPeersLeap NTPLeapIndicator,
|
|
rcNtpPeersMode INTEGER,
|
|
rcNtpPeersStratum NTPStratum,
|
|
rcNtpPeersPeerPoll NTPPollInterval,
|
|
rcNtpPeersHostPoll NTPPollInterval,
|
|
rcNtpPeersPrecision Integer32,
|
|
rcNtpPeersRootDelay NTPSignedTimeValue,
|
|
rcNtpPeersRootDispersion NTPUnsignedTimeValue,
|
|
rcNtpPeersRefId NTPRefId,
|
|
rcNtpPeersRefTime NTPTimeStamp,
|
|
rcNtpPeersOrgTime NTPTimeStamp,
|
|
rcNtpPeersReceiveTime NTPTimeStamp,
|
|
rcNtpPeersTransmitTime NTPTimeStamp,
|
|
rcNtpPeersUpdateTime Unsigned32,
|
|
rcNtpPeersReach Integer32,
|
|
rcNtpPeersTimer Integer32,
|
|
rcNtpPeersOffset NTPSignedTimeValue,
|
|
rcNtpPeersDelay NTPSignedTimeValue,
|
|
rcNtpPeersDispersion NTPUnsignedTimeValue,
|
|
rcNtpPeersFilterValidEntries Gauge32,
|
|
rcNtpPeersEntryStatus RowStatus,
|
|
rcNtpPeersVersion INTEGER
|
|
}
|
|
|
|
rcNtpPeersAssocId OBJECT-TYPE
|
|
SYNTAX NTPAssocIdentifier
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "An integer value greater than 0 that uniquely
|
|
identifies a peer with which the local NTP server
|
|
is associated."
|
|
::= { rcNtpPeersVarEntry 1 }
|
|
|
|
rcNtpPeersConfigured OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "This is a bit indicating that the association
|
|
was created from configuration information and
|
|
should not be de-associated even if the peer
|
|
becomes unreachable."
|
|
::= { rcNtpPeersVarEntry 2 }
|
|
|
|
rcNtpPeersPeerAddress OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION "The IP address of the peer. When creating a new
|
|
association, a value for this object should be set
|
|
before the row is made active."
|
|
::= { rcNtpPeersVarEntry 3 }
|
|
|
|
rcNtpPeersPeerPort OBJECT-TYPE
|
|
SYNTAX Integer32 (1..65535)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The UDP port number on which the peer receives NTP
|
|
messages."
|
|
::= { rcNtpPeersVarEntry 4 }
|
|
|
|
rcNtpPeersHostAddress OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION "The IP address of the local host. Multi-homing can
|
|
be supported using this object."
|
|
::= { rcNtpPeersVarEntry 5 }
|
|
|
|
rcNtpPeersHostPort OBJECT-TYPE
|
|
SYNTAX Integer32 (1..65535)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The UDP port number on which the local host receives
|
|
NTP messages."
|
|
::= { rcNtpPeersVarEntry 6 }
|
|
|
|
rcNtpPeersLeap OBJECT-TYPE
|
|
SYNTAX NTPLeapIndicator
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Two-bit code warning of an impending leap
|
|
second to be inserted in the NTP timescale of
|
|
the peer."
|
|
::= { rcNtpPeersVarEntry 7 }
|
|
|
|
rcNtpPeersMode OBJECT-TYPE
|
|
SYNTAX INTEGER { unspecified (0), symmetricActive (1),
|
|
symmetricPassive (2), client (3),
|
|
server(4), broadcast (5),
|
|
reservedControl (6),
|
|
reservedPrivate (7) }
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION "The association mode of the NTP server, with values
|
|
coded as follows,
|
|
0, unspecified
|
|
1, symmetric active - A host operating in this mode
|
|
sends periodic messages regardless of the
|
|
reachability state or stratum of its peer. By
|
|
operating in this mode the host announces its
|
|
willingness to synchronize and be synchronized
|
|
by the peer
|
|
2, symmetric passive - This type of association is
|
|
ordinarily created upon arrival of a message
|
|
from a peer operating in the symmetric active
|
|
mode and persists only as long as the peer is
|
|
reachable and operating at a stratum level
|
|
less than or equal to the host; otherwise, the
|
|
association is dissolved. However, the
|
|
association will always persist until at least
|
|
one message has been sent in reply. By
|
|
operating in this mode the host announces its
|
|
willingness to synchronize and be synchronized
|
|
by the peer
|
|
3, client - A host operating in this mode sends
|
|
periodic messages regardless of the
|
|
reachability state or stratum of its peer. By
|
|
operating in this mode the host, usually a LAN
|
|
workstation, announces its willingness to be
|
|
synchronized by, but not to synchronize the peer
|
|
4, server - This type of association is ordinarily
|
|
created upon arrival of a client request message
|
|
and exists only in order to reply to that
|
|
request, after which the association is
|
|
dissolved. By operating in this mode the host,
|
|
usually a LAN time server, announces its
|
|
willingness to synchronize, but not to be
|
|
synchronized by the peer
|
|
5, broadcast - A host operating in this mode sends
|
|
periodic messages regardless of the
|
|
reachability state or stratum of the peers.
|
|
By operating in this mode the host, usually a
|
|
LAN time server operating on a high-speed
|
|
broadcast medium, announces its willingness to
|
|
synchronize all of the peers, but not to be
|
|
synchronized by any of them
|
|
6, reserved for NTP control messages
|
|
7, reserved for private use.
|
|
|
|
When creating a new peer association, if no value
|
|
is specified for this object, it defaults to
|
|
symmetricActive(1)."
|
|
REFERENCE
|
|
"D.L. Mills, 'Network Time Protocol (Version 3)',
|
|
RFC-1305, March 1992, Section 3.3"
|
|
::= { rcNtpPeersVarEntry 8 }
|
|
|
|
rcNtpPeersStratum OBJECT-TYPE
|
|
SYNTAX NTPStratum
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The stratum of the peer clock."
|
|
::= { rcNtpPeersVarEntry 9 }
|
|
|
|
rcNtpPeersPeerPoll OBJECT-TYPE
|
|
SYNTAX NTPPollInterval
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The interval at which the peer polls the local host."
|
|
::= { rcNtpPeersVarEntry 10 }
|
|
|
|
rcNtpPeersHostPoll OBJECT-TYPE
|
|
SYNTAX NTPPollInterval
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The interval at which the local host polls the peer."
|
|
::= { rcNtpPeersVarEntry 11 }
|
|
|
|
rcNtpPeersPrecision OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Signed integer indicating the precision of the peer
|
|
clock, in seconds to the nearest power of two. The
|
|
value must be rounded to the next larger power of
|
|
two; for instance, a 50-Hz (20 ms) or 60-Hz
|
|
(16.67 ms) power-frequency clock would be assigned
|
|
the value -5 (31.25 ms), while a 1000-Hz (1 ms)
|
|
crystal-controlled clock would be assigned the value
|
|
-9 (1.95 ms)."
|
|
::= { rcNtpPeersVarEntry 12 }
|
|
|
|
rcNtpPeersRootDelay OBJECT-TYPE
|
|
SYNTAX NTPSignedTimeValue
|
|
UNITS "seconds"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "A signed fixed-point number indicating the total
|
|
round-trip delay in seconds, from the peer to the
|
|
primary reference source at the root of the
|
|
synchronization subnet."
|
|
::= { rcNtpPeersVarEntry 13 }
|
|
|
|
rcNtpPeersRootDispersion OBJECT-TYPE
|
|
SYNTAX NTPUnsignedTimeValue
|
|
UNITS "seconds"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The maximum error in seconds, of the peer clock
|
|
relative to the primary reference source at the root
|
|
of the synchronization subnet. Only positive values
|
|
greater than zero are possible."
|
|
::= { rcNtpPeersVarEntry 14 }
|
|
|
|
rcNtpPeersRefId OBJECT-TYPE
|
|
SYNTAX NTPRefId
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The reference identifier of the peer."
|
|
::= { rcNtpPeersVarEntry 15 }
|
|
|
|
rcNtpPeersRefTime OBJECT-TYPE
|
|
SYNTAX NTPTimeStamp
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The local time at the peer when its clock was last
|
|
updated. If the peer clock has never been
|
|
synchronized, the value is zero."
|
|
::= { rcNtpPeersVarEntry 16 }
|
|
|
|
rcNtpPeersOrgTime OBJECT-TYPE
|
|
SYNTAX NTPTimeStamp
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The local time at the peer, when its latest
|
|
NTP message was sent. If the peer becomes unreachable
|
|
the value is set to zero."
|
|
::= { rcNtpPeersVarEntry 17 }
|
|
|
|
rcNtpPeersReceiveTime OBJECT-TYPE
|
|
SYNTAX NTPTimeStamp
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The local time, when the latest NTP message from
|
|
the peer arrived. If the peer becomes unreachable
|
|
the value is set to zero."
|
|
::= { rcNtpPeersVarEntry 18 }
|
|
|
|
rcNtpPeersTransmitTime OBJECT-TYPE
|
|
SYNTAX NTPTimeStamp
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The local time at which the NTP message departed the
|
|
sender."
|
|
::= { rcNtpPeersVarEntry 19 }
|
|
|
|
rcNtpPeersUpdateTime OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The local time, when the most recent NTP message was
|
|
received from the peer that was used to calculate the
|
|
skew dispersion. This represents only the 32-bit
|
|
integer part of the NTPTimestamp."
|
|
::= { rcNtpPeersVarEntry 20 }
|
|
|
|
rcNtpPeersReach OBJECT-TYPE
|
|
SYNTAX Integer32 (0..255)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "A shift register of used to determine the
|
|
reachability status of the peer, with bits entering
|
|
from the least significant (rightmost) end. A peer is
|
|
considered reachable if at least one bit in this
|
|
register is set to one i.e, if the value of this
|
|
object is non-zero.
|
|
The data in the shift register would be populated by
|
|
the NTP protocol procedures."
|
|
REFERENCE
|
|
"D.L. Mills, 'Network Time Protocol (Version 3)',
|
|
RFC-1305, March 1992, Section 3.2.3"
|
|
::= { rcNtpPeersVarEntry 21 }
|
|
|
|
rcNtpPeersTimer OBJECT-TYPE
|
|
SYNTAX Integer32 (0..2147483647)
|
|
UNITS "seconds"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The interval in seconds, between transmitted NTP
|
|
messages from the local host to the peer."
|
|
REFERENCE
|
|
"D.L. Mills, 'Network Time Protocol (Version 3)',
|
|
RFC-1305, March 1992, Section 3.2.3"
|
|
::= { rcNtpPeersVarEntry 22 }
|
|
|
|
rcNtpPeersOffset OBJECT-TYPE
|
|
SYNTAX NTPSignedTimeValue
|
|
UNITS "seconds"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The estimated offset of the peer clock relative to
|
|
the local clock, in seconds. The host determines the
|
|
value of this object using the NTP clock-filter
|
|
algorithm."
|
|
REFERENCE
|
|
"D.L. Mills, 'Network Time Protocol (Version 3)',
|
|
RFC-1305, March 1992, Section 3.2.5"
|
|
::= { rcNtpPeersVarEntry 23 }
|
|
|
|
rcNtpPeersDelay OBJECT-TYPE
|
|
SYNTAX NTPSignedTimeValue
|
|
UNITS "seconds"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The estimated round-trip delay of the peer clock
|
|
relative to the local clock over the network path
|
|
between them, in seconds. The host determines the
|
|
value of this object using the NTP clock-filter
|
|
algorithm."
|
|
REFERENCE
|
|
"D.L. Mills, 'Network Time Protocol (Version 3)',
|
|
RFC-1305, March 1992, Section 3.2.5"
|
|
::= { rcNtpPeersVarEntry 24 }
|
|
|
|
rcNtpPeersDispersion OBJECT-TYPE
|
|
SYNTAX NTPUnsignedTimeValue
|
|
UNITS "seconds"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The estimated maximum error of the peer clock
|
|
relative to the local clock over the network path
|
|
between them, in seconds. The host determines the
|
|
value of this object using the NTP clock-filter
|
|
algorithm."
|
|
REFERENCE
|
|
"D.L. Mills, 'Network Time Protocol (Version 3)',
|
|
RFC-1305, March 1992, Section 3.2.5"
|
|
::= { rcNtpPeersVarEntry 25 }
|
|
|
|
rcNtpPeersFilterValidEntries OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The number of valid entries for a peer in the
|
|
Filter Register Table. Since, the Filter Register
|
|
Table is optional, this object will have a value 0
|
|
if the Filter Register Table is not implemented."
|
|
::= { rcNtpPeersVarEntry 26 }
|
|
|
|
|
|
rcNtpPeersEntryStatus OBJECT-TYPE
|
|
SYNTAX RowStatus
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION "The status object for this row. When a management
|
|
station is creating a new row, it should set the
|
|
value for rcNtpPeersPeerAddress at least, before the
|
|
row can be made active(1)."
|
|
::= { rcNtpPeersVarEntry 27 }
|
|
|
|
|
|
rcNtpPeersVersion OBJECT-TYPE
|
|
SYNTAX INTEGER{v1(1), v2(2),v3(3)}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Version of ntp,
|
|
v1: version 1,
|
|
v2: version 2,
|
|
v3: version 3."
|
|
DEFVAL { v3 }
|
|
::= { rcNtpPeersVarEntry 28 }
|
|
|
|
|
|
--
|
|
-- Filter Group
|
|
--
|
|
-- Implementation of this group is optional. It must be implemented
|
|
-- when the filter and selection algorithms described in Section 4
|
|
-- of RFC 1305 are used.
|
|
--
|
|
|
|
--
|
|
-- Filter Register Table
|
|
--
|
|
|
|
rcNtpFilterRegisterTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF RcNtpFilterRegisterEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "The following table contains NTP state variables
|
|
used by the NTP clock filter and selection algorithms.
|
|
This table depicts a shift register. Each stage in
|
|
the shift register is a 3-tuple consisting of the
|
|
measured clock offset, measured clock delay and
|
|
measured clock dispersion associated with a single
|
|
observation.
|
|
|
|
An important factor affecting the accuracy and
|
|
reliability of time distribution is the complex of
|
|
algorithms used to reduce the effect of statistical
|
|
errors and falsetickers due to failure of various
|
|
subnet components, reference sources or propagation
|
|
media. The NTP clock-filter and selection algorithms
|
|
are designed to do exactly this. The objects in the
|
|
filter register table below are used by these
|
|
algorthims to minimize the error in the calculated
|
|
time."
|
|
REFERENCE
|
|
"D.L. Mills, 'Network Time Protocol (Version 3)',
|
|
RFC-1305, March 1992, Section 3.2.5"
|
|
::= { rcNtpFilter 1 }
|
|
|
|
rcNtpFilterRegisterEntry OBJECT-TYPE
|
|
SYNTAX RcNtpFilterRegisterEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "Each entry corresponds to one stage of the shift
|
|
register, i.e., one reading of the variables clock
|
|
delay, clock offset and clock dispersion.
|
|
|
|
Entries are automatically created whenever a peer is
|
|
configured and deleted when the peer is removed."
|
|
INDEX { rcNtpPeersAssocId, rcNtpFilterIndex }
|
|
::= { rcNtpFilterRegisterTable 1 }
|
|
|
|
RcNtpFilterRegisterEntry ::= SEQUENCE {
|
|
rcNtpFilterIndex Integer32,
|
|
rcNtpFilterPeersOffset NTPSignedTimeValue,
|
|
rcNtpFilterPeersDelay NTPSignedTimeValue,
|
|
rcNtpFilterPeersDispersion NTPUnsignedTimeValue
|
|
}
|
|
|
|
rcNtpFilterIndex OBJECT-TYPE
|
|
SYNTAX Integer32 (1..8)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "An integer value in the specified range that is used
|
|
to index into the table. The size of the table is
|
|
fixed at 8. Each entry identifies a particular
|
|
reading of the clock filter variables in the shift
|
|
register.
|
|
|
|
Entries are added starting at index 1. The index
|
|
wraps back to 1 when it reaches 8. When the index
|
|
wraps back, the new entries will overwrite the old
|
|
entries effectively deleting the old entry."
|
|
::= { rcNtpFilterRegisterEntry 1 }
|
|
|
|
rcNtpFilterPeersOffset OBJECT-TYPE
|
|
SYNTAX NTPSignedTimeValue
|
|
UNITS "seconds"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The offset of the peer clock relative to the
|
|
local clock in seconds."
|
|
::= { rcNtpFilterRegisterEntry 2 }
|
|
|
|
rcNtpFilterPeersDelay OBJECT-TYPE
|
|
SYNTAX NTPSignedTimeValue
|
|
UNITS "seconds"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Round-trip delay of the peer clock relative to the
|
|
local clock over the network path between them, in
|
|
seconds. This variable can take on both positive and
|
|
negative values, depending on clock precision and
|
|
skew-error accumulation."
|
|
::= { rcNtpFilterRegisterEntry 3 }
|
|
|
|
rcNtpFilterPeersDispersion OBJECT-TYPE
|
|
SYNTAX NTPUnsignedTimeValue
|
|
UNITS "seconds"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The maximum error of the peer clock relative to the
|
|
local clock over the network path between them, in
|
|
seconds. Only positive values greater than zero are
|
|
possible."
|
|
::= { rcNtpFilterRegisterEntry 4 }
|
|
|
|
END
|
|
|