Observium_CE/mibs/radlan/MARVELL-TIMEBASED-PORT-SHUTDOWN-MIB

108 lines
3.2 KiB
Plaintext

MARVELL-TIMEBASED-PORT-SHUTDOWN-MIB DEFINITIONS ::= BEGIN
-- Title: MARVELL TIME-BASED PORT OPERATION Configuration
-- Version: 7.50.00.00
-- Date: 06-Aug-2011
--
IMPORTS
TruthValue,TEXTUAL-CONVENTION,DisplayString,
RowStatus FROM SNMPv2-TC
MODULE-IDENTITY, OBJECT-TYPE FROM SNMPv2-SMI
ifIndex FROM IF-MIB
PortList FROM Q-BRIDGE-MIB
rnd FROM RADLAN-MIB;
rlTimeBasedPort MODULE-IDENTITY
LAST-UPDATED "201108060000Z"
ORGANIZATION "Marvell Semiconductor, Inc."
CONTACT-INFO
"www.marvell.com"
DESCRIPTION
"The private MIB module definition for Time Based Port Operation MIB."
REVISION "201108060000Z"
DESCRIPTION
"Initial version of this MIB."
::= { rnd 208 }
rlTimeBasedPortVersion OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This scalar keep current supported version for Time Based Port feature.Initial version value is 1"
::= { rlTimeBasedPort 1 }
rlTimeBasedPortTable OBJECT-TYPE
SYNTAX SEQUENCE OF RlTimeBasedPortEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The table is used to manage time based port operation schedules."
::= { rlTimeBasedPort 2 }
rlTimeBasedPortEntry OBJECT-TYPE
SYNTAX RlTimeBasedPortEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry (conceptual row) in the rlTimeBasedPortEntry."
INDEX { ifIndex,rlTimeBasedPortTimeRangeName }
::= { rlTimeBasedPortTable 1 }
RlTimeBasedPortEntry ::= SEQUENCE {
rlTimeBasedPortTimeRangeName DisplayString,
rlTimeBasedPortAction INTEGER,
rlTimeBasedPortActive TruthValue,
rlTimeBasedPortRowStatus RowStatus
}
rlTimeBasedPortTimeRangeName OBJECT-TYPE
SYNTAX DisplayString(SIZE(1..32))
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Name of time range."
::= { rlTimeBasedPortEntry 1 }
rlTimeBasedPortAction OBJECT-TYPE
SYNTAX INTEGER {
up (1),
down (2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This field constitutes what action must be applyed to port during the time range."
::= { rlTimeBasedPortEntry 2 }
rlTimeBasedPortActive OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This field indicates if the time-range is active or not ."
::= { rlTimeBasedPortEntry 3 }
rlTimeBasedPortRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The status of a table entry.
It is used to delete an entry from this table."
::= { rlTimeBasedPortEntry 4 }
END