-- IPT-NETFLOW-MIB.my
PEPXIM-IPT-NETFLOW-MIB DEFINITIONS ::= BEGIN
IMPORTS
MODULE-IDENTITY, OBJECT-TYPE, Counter64,
Gauge32, Integer32, Counter32, enterprises
FROM SNMPv2-SMI
OBJECT-GROUP, MODULE-COMPLIANCE
FROM SNMPv2-CONF
CounterBasedGauge64
FROM HCNUM-TC
TEXTUAL-CONVENTION, DisplayString, DateAndTime
FROM SNMPv2-TC;
--
-- Node definitions
--
-- ********************************************************************
-- * MODULE IDENTITY
-- ********************************************************************
-- The Enterprises Number
pepxim OBJECT IDENTIFIER ::= { enterprises 52467 }
productMib OBJECT IDENTIFIER ::= { pepxim 200 }
generalMib OBJECT IDENTIFIER ::= { productMib 1 }
iptNetflowMIB MODULE-IDENTITY
LAST-UPDATED "202011121200Z" -- 11 12, 2020 at 12:00 GMT
ORGANIZATION "PEPXIM"
CONTACT-INFO ""
DESCRIPTION "MIB module for IPT-NETFLOW."
::= { generalMib 15 }
-- Top Level --
iptNetflowObjects OBJECT IDENTIFIER ::= { iptNetflowMIB 1 }
iptNetflowStatistics OBJECT IDENTIFIER ::= { iptNetflowMIB 2 }
iptNetflowConformance OBJECT IDENTIFIER ::= { iptNetflowMIB 3 }
-- Objects --
-- modinfo
iptNetflowModule OBJECT IDENTIFIER ::= { iptNetflowObjects 1 }
-- sysctl net.netflow
iptNetflowSysctl OBJECT IDENTIFIER ::= { iptNetflowObjects 2 }
-- Modinfo Objects --
name OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Name of the module."
::= { iptNetflowModule 1 }
version OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Software version of the module."
::= { iptNetflowModule 2 }
srcversion OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Binary version of the module."
::= { iptNetflowModule 3 }
loadTime OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Load date time of the module."
::= { iptNetflowModule 4 }
refcnt OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Module usage by other kernel objects."
::= { iptNetflowModule 5 }
-- RW Sysctl objects --
protocol OBJECT-TYPE
SYNTAX INTEGER {
netflow5(5),
netflow9(9),
ipfix(10)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Protocol version (5, 9, 10=IPFIX)."
::= { iptNetflowSysctl 1 }
hashsize OBJECT-TYPE
SYNTAX Integer32
UNITS "buckets"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Hash table size of flows cache."
::= { iptNetflowSysctl 2 }
maxflows OBJECT-TYPE
SYNTAX Integer32
UNITS "flows"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Max flows limit. This limit is used for DoS protection."
::= { iptNetflowSysctl 3 }
active-timeout OBJECT-TYPE
SYNTAX Integer32
UNITS "minutes"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Active flows timeout value."
::= { iptNetflowSysctl 4 }
inactive-timeout OBJECT-TYPE
SYNTAX Integer32
UNITS "minutes"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Inactive flows timeout value."
::= { iptNetflowSysctl 5 }
sndbuf OBJECT-TYPE
SYNTAX Integer32
UNITS "bytes"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Sockets SNDBUF size."
::= { iptNetflowSysctl 6 }
destination OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Export destination parameter."
::= { iptNetflowSysctl 7 }
aggregation OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Aggregation parameters."
::= { iptNetflowSysctl 8 }
sampler OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Sampler parameters: sampling mode:sampling interval.
Where sampling modes: deterministic, random, hash."
::= { iptNetflowSysctl 9 }
natevents OBJECT-TYPE
SYNTAX INTEGER {
disabled(0),
enabled(1)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Natevents (NEL) controlling parameter."
::= { iptNetflowSysctl 10 }
promisc OBJECT-TYPE
SYNTAX INTEGER {
disabled(0),
enabled(1)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Promisc hack controlling parameter."
::= { iptNetflowSysctl 11 }
snmp-rules OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"SNMP-index translation rules."
::= { iptNetflowSysctl 12 }
scan-min OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"scan-min parameter."
::= { iptNetflowSysctl 13 }
-- Statistics Objects --
iptNetflowTotals OBJECT IDENTIFIER ::= { iptNetflowStatistics 1 }
inBitRate OBJECT-TYPE
SYNTAX CounterBasedGauge64
UNITS "bits/second"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Total incoming bits per second."
::= { iptNetflowTotals 1 }
inPacketRate OBJECT-TYPE
SYNTAX Gauge32
UNITS "packets/second"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Total incoming packets per second."
::= { iptNetflowTotals 2 }
inFlows OBJECT-TYPE
SYNTAX Counter64
UNITS "flows"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Total observed (metered) flows."
::= { iptNetflowTotals 3 }
inPackets OBJECT-TYPE
SYNTAX Counter64
UNITS "packets"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Total metered packets(Not including dropped packets)."
::= { iptNetflowTotals 4 }
inBytes OBJECT-TYPE
SYNTAX Counter64
UNITS "bytes"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Total metered bytes of in packets."
::= { iptNetflowTotals 5 }
FixedDiv100 ::= TEXTUAL-CONVENTION
DISPLAY-HINT "d-2"
STATUS current
DESCRIPTION "Fixed point, two decimals."
SYNTAX Gauge32
hashMetric OBJECT-TYPE
SYNTAX FixedDiv100
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Measure of performance of hash table.
When optimal will be attract to 1.0.
When non-optimal will be highly above of 1."
::= { iptNetflowTotals 6 }
hashMemory OBJECT-TYPE
SYNTAX Gauge32
UNITS "bytes"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"System memory used by the hash table."
::= { iptNetflowTotals 7 }
hashFlows OBJECT-TYPE
SYNTAX Gauge32
UNITS "flows"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Flows currently residing in the hash table and not
exported yet."
::= { iptNetflowTotals 8 }
hashPackets OBJECT-TYPE
SYNTAX Gauge32
UNITS "packets"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Packets in flows currently residing in the hash table."
::= { iptNetflowTotals 9 }
hashBytes OBJECT-TYPE
SYNTAX CounterBasedGauge64
UNITS "bytes"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Bytes in flows currently residing in the hash table."
::= { iptNetflowTotals 10 }
dropPackets OBJECT-TYPE
SYNTAX Counter64
UNITS "packets"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Total packets dropped by metering process."
::= { iptNetflowTotals 11 }
dropBytes OBJECT-TYPE
SYNTAX Counter64
UNITS "bytes"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Total bytes in packets dropped by metering process."
::= { iptNetflowTotals 12 }
outByteRate OBJECT-TYPE
SYNTAX Gauge32
UNITS "bytes/second"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Total exporter output bytes per second."
::= { iptNetflowTotals 13 }
outFlows OBJECT-TYPE
SYNTAX Counter64
UNITS "flows"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Total exported flow data records."
::= { iptNetflowTotals 14 }
outPackets OBJECT-TYPE
SYNTAX Counter64
UNITS "packets"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Total exported packets of netflow stream itself."
::= { iptNetflowTotals 15 }
outBytes OBJECT-TYPE
SYNTAX Counter64
UNITS "bytes"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Total exported bytes of netflow stream itself."
::= { iptNetflowTotals 16 }
lostFlows OBJECT-TYPE
SYNTAX Counter64
UNITS "flows"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Total of accounted flows that are lost by exporting process
due to socket errors. This value will not include asynchronous
errors (cberr), these will be counted in errTotal."
::= { iptNetflowTotals 17 }
lostPackets OBJECT-TYPE
SYNTAX Counter64
UNITS "packets"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Total metered packets lost by exporting process.
See lostFlows for details."
::= { iptNetflowTotals 18 }
lostBytes OBJECT-TYPE
SYNTAX Counter64
UNITS "bytes"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Total bytes in packets lost by exporting process.
See lostFlows for details."
::= { iptNetflowTotals 19 }
errTotal OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Total exporting sockets errors (including cberr)."
::= { iptNetflowTotals 20 }
sndbufPeak OBJECT-TYPE
SYNTAX Counter32
UNITS "bytes"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Global maximum value of socket sndbuf. Sort of output
queue length."
::= { iptNetflowTotals 21 }
-- Per CPU statistics --
iptNetflowCpuTable OBJECT-TYPE
SYNTAX SEQUENCE OF IptNetflowCpuEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Per-CPU statistics."
::= { iptNetflowStatistics 2 }
iptNetflowCpuEntry OBJECT-TYPE
SYNTAX IptNetflowCpuEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Defines an entry in the iptNetflowCpuTable."
INDEX { cpuIndex }
::= { iptNetflowCpuTable 1 }
IptNetflowCpuEntry ::=
SEQUENCE {
cpuIndex Integer32,
cpuInPacketRate Gauge32,
cpuInFlows Counter64,
cpuInPackets Counter64,
cpuInBytes Counter64,
cpuHashMetric FixedDiv100,
cpuDropPackets Counter64,
cpuDropBytes Counter64,
cpuErrTrunc Counter32,
cpuErrFrag Counter32,
cpuErrAlloc Counter32,
cpuErrMaxflows Counter32
}
cpuIndex OBJECT-TYPE
SYNTAX Integer32 (0..4096)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Index of this CPU."
::= { iptNetflowCpuEntry 1 }
cpuInPacketRate OBJECT-TYPE
SYNTAX Gauge32
UNITS "packets/second"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Incoming packets per second for this CPU."
::= { iptNetflowCpuEntry 2 }
cpuInFlows OBJECT-TYPE
SYNTAX Counter64
UNITS "flows"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Flows metered on this CPU."
::= { iptNetflowCpuEntry 3 }
cpuInPackets OBJECT-TYPE
SYNTAX Counter64
UNITS "packets"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Packets metered for cpuIndex."
::= { iptNetflowCpuEntry 4 }
cpuInBytes OBJECT-TYPE
SYNTAX Counter64
UNITS "bytes"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Bytes metered on this CPU."
::= { iptNetflowCpuEntry 5 }
cpuHashMetric OBJECT-TYPE
SYNTAX FixedDiv100
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Measure of performance of hash table on this CPU."
::= { iptNetflowCpuEntry 6 }
cpuDropPackets OBJECT-TYPE
SYNTAX Counter64
UNITS "packets"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Packets dropped by metering process on this CPU."
::= { iptNetflowCpuEntry 7 }
cpuDropBytes OBJECT-TYPE
SYNTAX Counter64
UNITS "bytes"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Bytes in cpuDropPackets for this CPU."
::= { iptNetflowCpuEntry 8 }
cpuErrTrunc OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Truncated packets dropped for this CPU."
::= { iptNetflowCpuEntry 9 }
cpuErrFrag OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Fragmented packets dropped for this CPU."
::= { iptNetflowCpuEntry 10 }
cpuErrAlloc OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Packets dropped due to memory allocation errors."
::= { iptNetflowCpuEntry 11 }
cpuErrMaxflows OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Packets dropped due to maxflows limit being reached."
::= { iptNetflowCpuEntry 12 }
-- Per Socket statistics --
iptNetflowSockTable OBJECT-TYPE
SYNTAX SEQUENCE OF IptNetflowSockEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Per socket statistics."
::= { iptNetflowStatistics 3 }
iptNetflowSockEntry OBJECT-TYPE
SYNTAX IptNetflowSockEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Defines an entry in the iptNetflowSockTable."
INDEX { sockIndex }
::= { iptNetflowSockTable 1 }
IptNetflowSockEntry ::=
SEQUENCE {
sockIndex Integer32,
sockDestination DisplayString,
sockActive INTEGER,
sockErrConnect Counter32,
sockErrFull Counter32,
sockErrCberr Counter32,
sockErrOther Counter32,
sockSndbuf Gauge32,
sockSndbufFill Gauge32,
sockSndbufPeak Gauge32
}
sockIndex OBJECT-TYPE
SYNTAX Integer32 (0..4096)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Exporting socket index."
::= { iptNetflowSockEntry 1 }
sockDestination OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Exporting connection destination of socket."
::= { iptNetflowSockEntry 2 }
sockActive OBJECT-TYPE
SYNTAX INTEGER {
inactive(0),
active(1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Connection state of socket."
::= { iptNetflowSockEntry 3 }
sockErrConnect OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Connections attempt count.
High value usually mean that network is not set up properly,
or module is loaded before network is up."
::= { iptNetflowSockEntry 4 }
sockErrFull OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Socket full errors on this socket. Usually mean sndbuf
value is too small."
::= { iptNetflowSockEntry 5 }
sockErrCberr OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Asynchronous callback errors on this socket. Usually mean
that there is 'connection refused' errors on UDP socket
reported via ICMP messages."
::= { iptNetflowSockEntry 6 }
sockErrOther OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"All other possible errors on this socket."
::= { iptNetflowSockEntry 7 }
sockSndbuf OBJECT-TYPE
SYNTAX Gauge32
UNITS "bytes"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Sndbuf value for this socket.
Higher value allows accommodate (exporting) traffic bursts."
::= { iptNetflowSockEntry 8 }
sockSndbufFill OBJECT-TYPE
SYNTAX Gauge32
UNITS "bytes"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Amount of data currently in socket buffers.
When this value will reach size sndbuf, packet loss will occur."
::= { iptNetflowSockEntry 9 }
sockSndbufPeak OBJECT-TYPE
SYNTAX Gauge32
UNITS "bytes"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Historical peak amount of data in socket buffers.
Useful to evaluate sndbuf size, due to sockSndbufFill is transient."
::= { iptNetflowSockEntry 10 }
-- Conformance Information --
iptNetflowCompliances OBJECT IDENTIFIER ::= { iptNetflowConformance 1 }
iptNetflowGroups OBJECT IDENTIFIER ::= { iptNetflowConformance 2 }
iptNetflowCompliance MODULE-COMPLIANCE
STATUS current
DESCRIPTION "iptNetflowCompliance"
MODULE
MANDATORY-GROUPS {
iptNetflowModuleGroup,
iptNetflowSysctlGroup,
iptNetflowTotalsGroup,
iptNetflowCpuGroup,
iptNetflowSockGroup
}
::= { iptNetflowCompliances 1 }
iptNetflowModuleGroup OBJECT-GROUP
OBJECTS {
name,
version,
srcversion,
loadTime,
refcnt
}
STATUS current
DESCRIPTION "Module info."
::= { iptNetflowGroups 1 }
iptNetflowSysctlGroup OBJECT-GROUP
OBJECTS {
hashsize,
maxflows,
protocol,
active-timeout,
inactive-timeout,
sndbuf,
destination,
aggregation,
sampler,
natevents,
promisc,
snmp-rules,
scan-min
}
STATUS current
DESCRIPTION "Read-write objects accessed via sysctl"
::= { iptNetflowGroups 2 }
iptNetflowTotalsGroup OBJECT-GROUP
OBJECTS {
inBitRate,
inPacketRate,
inFlows,
inPackets,
inBytes,
hashMetric,
hashMemory,
hashFlows,
hashPackets,
hashBytes,
dropPackets,
dropBytes,
outByteRate,
outFlows,
outPackets,
outBytes,
lostFlows,
lostPackets,
lostBytes,
errTotal,
sndbufPeak
}
STATUS current
DESCRIPTION "Statistics totals."
::= { iptNetflowGroups 3 }
iptNetflowCpuGroup OBJECT-GROUP
OBJECTS {
cpuIndex,
cpuInPacketRate,
cpuInFlows,
cpuInPackets,
cpuInBytes,
cpuHashMetric,
cpuDropPackets,
cpuDropBytes,
cpuErrTrunc,
cpuErrFrag,
cpuErrAlloc,
cpuErrMaxflows
}
STATUS current
DESCRIPTION "Per CPU statistics."
::= { iptNetflowGroups 4 }
iptNetflowSockGroup OBJECT-GROUP
OBJECTS {
sockDestination,
sockActive,
sockErrConnect,
sockErrFull,
sockErrCberr,
sockErrOther,
sockSndbuf,
sockSndbufFill,
sockSndbufPeak
}
STATUS current
DESCRIPTION "Per socket statistics."
::= { iptNetflowGroups 5 }
END