Observium_CE/mibs/paradyne/PDN-STACKABLE-MIB

438 lines
16 KiB
Plaintext

-- ====================================================================
-- == Copyright (C) 2004 Paradyne Corporation. ==
-- ====================================================================
PDN-STACKABLE-MIB DEFINITIONS ::= BEGIN
IMPORTS
MODULE-IDENTITY, OBJECT-TYPE, Unsigned32, NOTIFICATION-TYPE,
Integer32
FROM SNMPv2-SMI
OBJECT-GROUP, NOTIFICATION-GROUP, MODULE-COMPLIANCE
FROM SNMPv2-CONF
DisplayString, TruthValue
FROM SNMPv2-TC
pdn-common
FROM PDN-HEADER-MIB
SwitchState
FROM PDN-TC;
pdnStackable MODULE-IDENTITY
LAST-UPDATED "200409140000Z" -- September 14, 2003
ORGANIZATION "Paradyne Networks
MIB Working Group
Other information about group editing the MIB"
CONTACT-INFO "Paradyne Networks, Inc.
8545 126th Avenue North
Largo, FL 33733
www.paradyne.com
General Comments to: mibwg_team@paradyne.com
Editors
Clay Sikes"
DESCRIPTION
"This MIB contains objects that are used for configuration and
statistics reporting things that are unique to a stackable product."
REVISION "200409140000Z" -- September 14, 2004
DESCRIPTION "Added stack links for the Verdun ML PPP project. Also,
cleaned up errors flaged by libsmi. These changes were
radical, but only effected stuff that has not been
implemented in any agents."
REVISION "200303120000Z" -- March 12, 2003
DESCRIPTION "Added third stack link for the Verdun product."
REVISION "200207310000Z" -- June 31, 2002
DESCRIPTION "Added Single Management Entity objects"
REVISION "200205150000Z" -- May 15, 2002
DESCRIPTION "Initial Release."
::= { pdn-common 36 }
-- ====================================================================
-- == Define groups for Notifications, MIB Objects, Accessible for ==
-- == Notifications (AFNs), and Conformance. ==
-- == These may just be place holders. ==
-- ====================================================================
pdnStackableNotifications OBJECT IDENTIFIER ::= { pdnStackable 0 }
pdnStackableObjects OBJECT IDENTIFIER ::= { pdnStackable 1 }
pdnStackableAFNs OBJECT IDENTIFIER ::= { pdnStackable 2 }
pdnStackableConformance OBJECT IDENTIFIER ::= { pdnStackable 3 }
-- ====================================================================
-- == Textual Conventions ==
-- ====================================================================
-- None defined
-- ====================================================================
-- == MIB Objects ==
-- ====================================================================
-- The WAN Interface Group
wanInterface OBJECT-TYPE
SYNTAX BITS {
stackLink1(0),
stackLink2(1),
plugInModule(2),
stackLink3(3),
stackLink4(4),
stackLink5(5),
stackLink6(6),
stackLink7(7),
stackLink8(8),
stackLink9(9),
stackLink10(10),
stackLink11(11),
stackLink12(12),
stackLink13(13),
stackLink14(14),
stackLink15(15),
stackLink16(16),
stackLink17(17),
stackLink18(18)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION "This object allows the WAN interface to be selected. Given
that the syntax for this object is BITS, it is intented that
the implementation could support multiple-simulatneous
uplinks.
There is no default value suggested or specified with a
DEFVAL directive. The intent is that the particular
project using this MIB object will specify its own
default value. It seems like projects using this MIB object
may be different enough that it would not be a good idea to
specify a default here."
::= { pdnStackableObjects 1 }
pdnStackMethod OBJECT-TYPE
SYNTAX INTEGER {
daisyChain(1),
star(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION "This object identifies the method by which units are
interconnected."
::= { pdnStackableObjects 2 }
pdnStackConfigurationTable OBJECT-TYPE
SYNTAX SEQUENCE OF PdnStackConfigurationEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "This table is used to display the stack configuration.
Implementation details regarding units becoming attached to
or removed from the Stack should be covered in the
implementation's Operational Specification."
::= { pdnStackableObjects 3 }
pdnStackConfigurationEntry OBJECT-TYPE
SYNTAX PdnStackConfigurationEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "Each entry represents a unit in the stack."
INDEX { pdnUnitExternalID }
::= { pdnStackConfigurationTable 1 }
PdnStackConfigurationEntry ::=
SEQUENCE {
pdnUnitExternalID Unsigned32,
pdnUnitEntPhysicalIndex INTEGER,
pdnUnitAssigned TruthValue,
pdnUnitGUID DisplayString,
pdnUnitPresent TruthValue
}
pdnUnitExternalID OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "This object is the External ID used to refer
to a particular unit. The value of this
External ID will typically be indicated on
the unit by some means such as a LED."
::= { pdnStackConfigurationEntry 1 }
pdnUnitEntPhysicalIndex OBJECT-TYPE
SYNTAX Integer32 (1..2147483647)
MAX-ACCESS read-only
STATUS current
DESCRIPTION "This object serves to map the table row to
an entry into the entPhysicalTable. This object
will contain the entPhysicalIndex associated with
the unit."
::= { pdnStackConfigurationEntry 2 }
pdnUnitAssigned OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION "This object indicates if the External ID has been
assigned to a particular Globally Unique Identifier (GUID).
Writing a false(2) is a mechanism to
delete a unit from a stack. When a unit is deleted from
a stack, all data that the Stack knows about the unit
is purged.
On read operations:
true(1) - indicates that the External ID has been
assigned to a unit
false(2) - indicates that the External ID has not
been assigned to a unit"
::= { pdnStackConfigurationEntry 3 }
pdnUnitGUID OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION "This object is the representation of the units'
Globally Unique Identifier (GUID). The requirement
for this identifier is that is something that makes
the unit uniquely identifiable. A MAC addresses is
an example of something that could be used as a GUID.
The particular implementation's Operational Specification
should clarify what is used as the implementation's
GUID."
::= { pdnStackConfigurationEntry 4 }
pdnUnitPresent OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION "This object identifies if the unit is present in the
stack. Note that when a unit is removed from a stack,
its stack and configuration information is retained.
true(1) - indicates that the unit is present
false(2) - indicates that the unit is no present"
::= { pdnStackConfigurationEntry 5 }
pdnMoveUnitCmdTable OBJECT-TYPE
SYNTAX SEQUENCE OF PdnMoveUnitCmdEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "This table contains the objects necessary to support a command
to move a unit in a stack. This command only applies when
singleManagementEntity is enabled."
::= { pdnStackableObjects 4 }
pdnMoveUnitCmdEntry OBJECT-TYPE
SYNTAX PdnMoveUnitCmdEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The table has a single row supporting a command to move a
unit in a stack."
INDEX { pdnMoveUnitSrcNumber, pdnMoveUnitDestNumber }
::= { pdnMoveUnitCmdTable 1 }
PdnMoveUnitCmdEntry ::=
SEQUENCE {
pdnMoveUnitSrcNumber Unsigned32,
pdnMoveUnitDestNumber Unsigned32,
pdnMoveUnitCmd INTEGER
}
pdnMoveUnitSrcNumber OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "This object is used as a table index and serves as the identifier for
the source unit in the move command. The implementation's Operational
Specification should clearly specify what this object represents.
For example, this object could be what is refered to as the
unit's External ID."
::= { pdnMoveUnitCmdEntry 1 }
pdnMoveUnitDestNumber OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "This object is used as a table index and serves as the identifier for
the destination unit in the move command.The implementation's Operational
Specification should clearly specify what this object represents.
For example, this object could be what is refered to as the
unit's External ID."
::= { pdnMoveUnitCmdEntry 2 }
pdnMoveUnitCmd OBJECT-TYPE
SYNTAX INTEGER {
noOp(1),
move(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Writing the value move(2) will cause the stack and configuration
related information for the source unit to be moved to the
destination unit. This object always returns a noOp(1) on a
read operation."
::= { pdnMoveUnitCmdEntry 3 }
pdnStackUnitAddedTrapEnable OBJECT-TYPE
SYNTAX SwitchState
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Indicates whether the pdnStackUnitAdded trap should be
generated. The following values are defined for this object:
enabled(1) - Generates the trap
disabled(2) - Does not generate the trap"
::= { pdnStackableObjects 5 }
pdnStackUnitComFailureTrapEnable OBJECT-TYPE
SYNTAX SwitchState
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Indicates whether the pdnStackUnitComFailure trap should be
generated. The following values are defined for this object:
enabled(1) - Generates the trap
disabled(2) - Does not generate the trap"
::= { pdnStackableObjects 6 }
pdnStackUnitComRestoredTrapEnable OBJECT-TYPE
SYNTAX SwitchState
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Indicates whether the pdnStackUnitComRestored trap should be
generated. The following values are defined for this object:
enabled(1) - Generates the trap
disabled(2) - Does not generate the trap"
::= { pdnStackableObjects 7 }
-- ====================================================================
-- == Traps ==
-- ====================================================================
pdnStackUnitAdded NOTIFICATION-TYPE
OBJECTS { pdnUnitGUID }
STATUS current
DESCRIPTION "This trap signifies that a new unit has been added to a
stack."
::= { pdnStackableNotifications 1 }
pdnStackUnitComFailure NOTIFICATION-TYPE
OBJECTS { pdnUnitGUID }
STATUS current
DESCRIPTION "This trap signifies that a loss of communication has occured
with a unit that was part of a stack."
::= { pdnStackableNotifications 2 }
pdnStackUnitComRestored NOTIFICATION-TYPE
OBJECTS { pdnUnitGUID }
STATUS current
DESCRIPTION "This trap signifies that communication to a unit that was
part of the stack has occured."
::= { pdnStackableNotifications 3 }
-- ====================================================================
-- == Conformance Information ==
-- ====================================================================
pdnStackableCompliances OBJECT IDENTIFIER ::= { pdnStackableConformance 1 }
pdnStackableGroups OBJECT IDENTIFIER ::= { pdnStackableConformance 2 }
-- ===========================
-- == Compliance Statements ==
-- ===========================
pdnStackableConmpliance MODULE-COMPLIANCE
STATUS current
DESCRIPTION "The compliance statement for elements implementing
stackable units."
MODULE -- this module
-- No mandatory groups are specified.
GROUP wanInterfaceGroup
DESCRIPTION "This group is only required for implementations that
need to select the WAN interface(s)."
GROUP singleManagementEntityGroup
DESCRIPTION "This group is only required for implementations that
implement a `single logical management entity'. "
GROUP singleManagementEntityNotificationGroup
DESCRIPTION "This group is only required for implementations that
generate notification related to the `single logical
management entity`."
::= { pdnStackableCompliances 1 }
-- ==========================
-- == Units of Conformance ==
-- ==========================
pdnStackableObjGroups OBJECT IDENTIFIER ::= { pdnStackableGroups 1 }
pdnStackableAfnGroups OBJECT IDENTIFIER ::= { pdnStackableGroups 2 }
pdnStackableNtfyGroups OBJECT IDENTIFIER ::= { pdnStackableGroups 3 }
-- ============================
-- == pdnStackableObjGroups ==
-- ============================
wanInterfaceGroup OBJECT-GROUP
OBJECTS {
wanInterface
}
STATUS current
DESCRIPTION "Objects related to the WAN."
::= { pdnStackableObjGroups 1 }
singleManagementEntityGroup OBJECT-GROUP
OBJECTS {
pdnStackMethod,
pdnUnitEntPhysicalIndex,
pdnUnitAssigned,
pdnUnitGUID,
pdnUnitPresent,
pdnMoveUnitCmd,
pdnStackUnitAddedTrapEnable,
pdnStackUnitComFailureTrapEnable,
pdnStackUnitComRestoredTrapEnable
}
STATUS current
DESCRIPTION "Objects related to the Single Management Entity."
::= { pdnStackableObjGroups 2 }
-- ============================
-- == pdnStackableAfnGroups ==
-- ============================
-- None.
-- =============================
-- == pdnStackableNtfyGroups ==
-- =============================
singleManagementEntityNotificationGroup NOTIFICATION-GROUP
NOTIFICATIONS {
pdnStackUnitAdded,
pdnStackUnitComFailure,
pdnStackUnitComRestored
}
STATUS current
DESCRIPTION "Notifications that must be implemented for Single
Management Entity implementations."
::= { pdnStackableNtfyGroups 1 }
END