Observium_CE/mibs/paradyne/PDN-SPECTRUMMGMT-MIB

962 lines
31 KiB
Plaintext

PDN-SPECTRUMMGMT-MIB DEFINITIONS ::= BEGIN
----------------------------------------------------------------
-- Copyright (C) 2003, Paradyne. All rights reserved.
----------------------------------------------------------------
IMPORTS
Integer32, Unsigned32,
OBJECT-TYPE, MODULE-IDENTITY
FROM SNMPv2-SMI
MODULE-COMPLIANCE, OBJECT-GROUP
FROM SNMPv2-CONF
entPhysicalIndex
FROM ENTITY-MIB
ifIndex, ifType
FROM IF-MIB
pdn-interfaces
FROM PDN-HEADER-MIB;
pdnSpectrumMgmt MODULE-IDENTITY
LAST-UPDATED "200212091500Z"
ORGANIZATION "Paradyne Corp MIB Working Group"
CONTACT-INFO "Paradyne Networks, Inc.
8545 126th Ave North
Largo, FL 33733
www.paradyne.com
General Comments to:
mibwg_team@eng.paradyne.com
Editors: R.A.Bowhall,
Jesus Pinto"
DESCRIPTION "R.A.Bowhall
The Paradyne enterprise SPECTRUM MIB.
This MIB is written to facilitate spectrum
management of any xDSL interfaces. This mib
replaces older versions of the spectrum
management including the reachDSL.mib."
REVISION "200301151300Z"
DESCRIPTION "Jesus Pinto
1. Changed indexes on GeneralConfigTable.
2. Removed DSL Line Table.
3. Renamed newSpectrumMgmtAturMaxTxRate
4. Renamed newSpectrumMgmtAturMinTxRate
5. Renamed newSpectrumMgmtAturTxPower
6. Renamed newSpectrumMgmtAtucMinTxRate
7. Renamed newSpectrumMgmtAtucMaxTxRate
8. Renamed newSpectrumMgmtAtucTxPower
9. Added newSpectrumMgmtXturMax2TxRate
10.Added newSpectrumMgmtXturMin2TxRate
11.Added newSpectrumMgmtXtucMax2TxRate
12.Added newSpectrumMgmtXtucMax2TxRate"
REVISION "200301091500Z"
DESCRIPTION "Jesus Pinto
1. Deprecated spectrumMgmtTable and all its objects.
2. Added newSpectrumMgmtTable.
3. Added newSpectrumMgmtMode.
4. Added newSpectrumMgmtEWLUnits.
5. Added newSpectrumMgmtLoopMeasurementMethod.
6. Added newSpectrumMgmtLineInfoTable.
7. Added newSpectrumMgmtGeneralConfigTable."
REVISION "0105161530Z"
DESCRIPTION "R.A.Bowhall
Added DEFVAL caluse, Added the pdnSpecMgmtTraps,
and pdnSpecMgmtMIBConformance info.
Added an Informational Note at the Beginning of
this MIB."
REVISION "0105080550Z"
DESCRIPTION "R.A.Bowhall
Added the EWL Deployment Guidelines Table
and Changed spectrumMgmtAllowedSpeeds to
spectrumMgmtAllowedSpeedsMin1, spectrumMgmtAllowedSpeedsMax1,
spectrumMgmtAllowedSpeedsMin2, spectrumMgmtAllowedSpeedsMax2"
::= { pdn-interfaces 19 }
pdnSpecMgmtObjects OBJECT IDENTIFIER ::= { pdnSpectrumMgmt 1 }
pdnNewSpecMgmtObjects OBJECT IDENTIFIER ::= { pdnSpectrumMgmt 2 }
--
-- START OF Spectrum Management definitions
--
--
-- General options for spectrum management
--
newSpectrumMgmtGeneralConfigTable OBJECT-TYPE
SYNTAX SEQUENCE OF NewSpectrumMgmtGeneralConfigEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"General Configuration of the spectrum management.
This table contains an entry for each technology
managed by this device."
::= { pdnNewSpecMgmtObjects 1 }
newSpectrumMgmtGeneralConfigEntry OBJECT-TYPE
SYNTAX NewSpectrumMgmtGeneralConfigEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry with the general spectrum mgmt configuration
parameters for a specific DSL technology."
INDEX { entPhysicalIndex, ifType }
::= { newSpectrumMgmtGeneralConfigTable 1 }
NewSpectrumMgmtGeneralConfigEntry ::= SEQUENCE {
newSpectrumMgmtSelection INTEGER,
newSpectrumMgmtMode INTEGER,
newSpectrumMgmtLoopMeasurementMethod INTEGER,
newSpectrumMgmtEWLUnits INTEGER
}
newSpectrumMgmtSelection OBJECT-TYPE
SYNTAX INTEGER {
enabled(1),
disabled(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object is used to Enable or Disable
Spectrum Management on DSL interfaces
managed by this device. Enabling this object
limits the DSL speeds on each port based on
line length in order to meet ANSI T1.417
Spectrum Management requirements or BT Access
Network Spectrum requirements.
The values that this object can accept are
controlled by the -Mode- object."
::= { newSpectrumMgmtGeneralConfigEntry 1 }
newSpectrumMgmtMode OBJECT-TYPE
SYNTAX INTEGER {
enableOnly(1),
disableOnly(2),
both(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object restricts the MAX-ACCESS of the 'Selection'
object.
Following are the details of each of the values:
enableOnly(1) - Indicates that the 'Selection' object
IS always 'enabled' and cannot be set
to 'disabled'.
disableOnly(2) - Indicates that the 'Selection' object
IS always 'disabled' and cannot be set
to 'enabled'.
both(3) - Indicates that the 'Selection' object
will accept both the 'enabled' and
'disabled' values."
::= { newSpectrumMgmtGeneralConfigEntry 2 }
newSpectrumMgmtLoopMeasurementMethod OBJECT-TYPE
SYNTAX INTEGER {
none(1),
loopLength(2),
ewl(3),
quadMode(4)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object indicates the measurement method used in
describing the Loop Length of a circuit. Following are the
details of each of the options:
none(1) - Indicates that the Spectral Compliance
is NOT dependant on any Loop Length
measurements or configurations.
loopLength(2) - The 'ConfLoopLength' object is used to
determine spectral compliance. The
'ConfEWL' & 'ConfQuadMode' objects are
not used in this mode.
ewl(3) - The 'ConfEWL' object is used to
configure the estimated loop length,
which is used to determine spectral
compliance. In this mode the
'ConfLoopLength' & 'ConfQuadMode'
objects are not used.
quadMode(4) - The 'ConfQuadMode' object is used to
determine spectral compliance. The
'ConfEWL' & 'ConfLoopLength' objects
are not used in this mode.
This object determines which of the three objects :
'ConfEWL', 'ConfLoopLength' or 'ConfQuadMode' is used
(if any) to enforce spectrally compliant maximum
'Tx Rates' and the maximum allowed 'Tx Power' on a given
circuit."
::= { newSpectrumMgmtGeneralConfigEntry 3 }
newSpectrumMgmtEWLUnits OBJECT-TYPE
SYNTAX INTEGER {
none(1),
feet(2),
meters(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object indicates the units of measurement used in
describing the Estimated Working Length of a circuit.
Following are the details of each of the units:
none(1) - Indicates that the Spectral Compliance is
NOT dependant on the 'ConfEWL' object.
feet(2) - The 'ConfEWL' is measured and configured
in feet.
meters(3) - The 'ConfEWL' is measured and configured
in meters."
::= { newSpectrumMgmtGeneralConfigEntry 4 }
--
-- Spectrum Mgmt Configuration Table
--
newSpectrumMgmtConfTable OBJECT-TYPE
SYNTAX SEQUENCE OF NewSpectrumMgmtConfEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The new Spectrum Management Configuration Table
This table is used for configuring spectrum management
objects on any DSL interface."
::= { pdnNewSpecMgmtObjects 2 }
newSpectrumMgmtConfEntry OBJECT-TYPE
SYNTAX NewSpectrumMgmtConfEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the xDSL Spectrum Management
Configuration table.
Note: This entry can be accessed only for ifIndex
values that belong to a physical interface.
e.g. for ifType = 'shdsl' (IANAifType=169)."
INDEX { ifIndex }
::= { newSpectrumMgmtConfTable 1 }
NewSpectrumMgmtConfEntry ::=
SEQUENCE {
newSpectrumMgmtConfEWL Unsigned32,
newSpectrumMgmtConfLoopLength INTEGER,
newSpectrumMgmtConfQuadMode INTEGER
}
newSpectrumMgmtConfEWL OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The Equivalent Working Length (EWL). The value selected
corresponds to the estimated length of the line in
feet - if 'EWLUnits' object is 'feet'.
meters - if 'EWLUnits' object is 'meters'.
This value is usually specified by the carrier and MUST
be in integral multiples of
500 feet, if 'EWLUnits' is 'feet'.
200 meters, if 'EWLUnits' is 'meters'.
The range of values that this object can take is determined
by the 'MinEWL' and 'MaxEWL' objects.
Changing this object may limit the maximum transmit power
and the effective DSL speeds at which the ports train up.
Note: This object will be used only if Spectrum Management
is enabled and 'LoopMeasurementMethod' is 'ewl'.
This object shares a mutual exclusion relationship
with the 'ConfLoopLength' & 'ConfQuadMode' objects,
as only one of the two will be used for configuration
at any time."
::= { newSpectrumMgmtConfEntry 1 }
newSpectrumMgmtConfLoopLength OBJECT-TYPE
SYNTAX INTEGER {
short(1),
medium(2),
long(3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This entry specifies the loop length for the line. The
configurable values are short(1), medium(2) and long(3).
The 'Loop Length' feature can be used only if the
'shdslSpectrumMgmtSelection' object is Enabled and
the 'LoopMeasurementMethod' is 'loopLength'. Changing this
object may limit the maximum transmit power and the
effective DSL speeds at which ports train up.
Note: This object shares a mutual exclusion relationship
with the 'ConfEWL' objects. i.e. only one of the
three can be used for configuration at one time."
::= { newSpectrumMgmtConfEntry 2 }
newSpectrumMgmtConfQuadMode OBJECT-TYPE
SYNTAX INTEGER {
sameQuad(1),
segregatedQuadUpto3km(2),
segregatedQuadAbove3km(3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This entry specifies the quad cable configuration &
length for the line. The configurable values are
sameQuad(1), segregatedQuadUpto3km(2) and
segregatedQuadAbove3km(3). The 'Quad Mode' feature can be
used only if the 'reachDSLSpectrumMgmtSelection' object
is Enabled and the 'LoopMeasurementMethod' is 'quadMode'.
Changing this object may limit the maximum transmit power
and the effective DSL speeds at which ports train up.
Note: This object shares a mutual exclusion relationship
with the 'ConfEWL' & 'ConfLoopLength' objects.
i.e. only one of the three can be used for
configuration at one time."
::= { newSpectrumMgmtConfEntry 3 }
--
-- Spectrum Management Line Info Table
--
newSpectrumMgmtLineInfoTable OBJECT-TYPE
SYNTAX SEQUENCE OF NewSpectrumMgmtLineInfoEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The Spectrum Management Line Info Table.
This table gives information about the spectrum
management ranges that are applicable for each port,
based on the spectral requirements for the device."
::= { pdnNewSpecMgmtObjects 3 }
newSpectrumMgmtLineInfoEntry OBJECT-TYPE
SYNTAX NewSpectrumMgmtLineInfoEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the newSpectrumMgmtLineInfoTable table.
Note: This entry can be accessed only for ifIndex values
that belong to a physical interface.
e.g. for ifType = 'adsl'."
INDEX { ifIndex }
::= { newSpectrumMgmtLineInfoTable 1 }
NewSpectrumMgmtLineInfoEntry ::=
SEQUENCE {
newSpectrumMgmtXtucMax1TxRate Unsigned32,
newSpectrumMgmtXtucMin1TxRate Unsigned32,
newSpectrumMgmtXtucMax2TxRate Unsigned32,
newSpectrumMgmtXtucMin2TxRate Unsigned32,
newSpectrumMgmtXtucMaxTxPower INTEGER,
newSpectrumMgmtXturMax1TxRate Unsigned32,
newSpectrumMgmtXturMin1TxRate Unsigned32,
newSpectrumMgmtXturMax2TxRate Unsigned32,
newSpectrumMgmtXturMin2TxRate Unsigned32,
newSpectrumMgmtXturMaxTxPower INTEGER,
newSpectrumMgmtMinEWL Unsigned32,
newSpectrumMgmtMaxEWL Unsigned32
}
newSpectrumMgmtXtucMax1TxRate OBJECT-TYPE
SYNTAX Unsigned32
UNITS "bps"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This rate will be the max allowed Tx Rate(in bps) for
the port based on the Spectrum Management requirements for
XTUC in a particular spectral compliance configuration.
Some measurement methods may have more than one range for
the TxRate. Min1TxRate and Max1TxRate will always have
the first range of values and the Min2TxRate and Max2TxRate
will have the second range if the method demands it."
::= { newSpectrumMgmtLineInfoEntry 1 }
newSpectrumMgmtXtucMin1TxRate OBJECT-TYPE
SYNTAX Unsigned32
UNITS "bps"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This rate will be the min allowed Tx Rate based on the
spectrum management requirements for the XTUC. The
MinTxRate will be upper bounded by
'newSpectrumMgmtXtucMax1TxRate' object.
Some measurement methods may have more than one range for
the TxRate. Min1TxRate and Max1TxRate will always have
the first range of values and the Min2TxRate and Max2TxRate
will have the second range if the method demands it."
::= { newSpectrumMgmtLineInfoEntry 2 }
newSpectrumMgmtXtucMax2TxRate OBJECT-TYPE
SYNTAX Unsigned32
UNITS "bps"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This rate will be the max allowed Tx Rate(in bps) for
the port based on the Spectrum Management requirements for
XTUC in a particular spectral compliance configuration.
This object is the
Some measurement methods may have more than one range for
the TxRate. Min1TxRate and Max1TxRate will always have
the first range of values and the Min2TxRate and Max2TxRate
will have the second range if the method demands it."
::= { newSpectrumMgmtLineInfoEntry 3 }
newSpectrumMgmtXtucMin2TxRate OBJECT-TYPE
SYNTAX Unsigned32
UNITS "bps"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This rate will be the min allowed Tx Rate based on the
spectrum management requirements for the XTUC. The
MinTxRate will be upper bounded by
'newSpectrumMgmtXtucMax1TxRate' object.
Some measurement methods may have more than one range for
the TxRate. Min1TxRate and Max1TxRate will always have
the first range of values and the Min2TxRate and Max2TxRate
will have the second range if the method demands it."
::= { newSpectrumMgmtLineInfoEntry 4 }
newSpectrumMgmtXtucMaxTxPower OBJECT-TYPE
SYNTAX INTEGER(-140..120)
UNITS "tenth dB"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The maximum transmit power at the ATUC (in tenth dB).
This value will be based on the spectrum management
selection."
::= { newSpectrumMgmtLineInfoEntry 5 }
newSpectrumMgmtXturMax1TxRate OBJECT-TYPE
SYNTAX Unsigned32
UNITS "bps"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This rate will be the max allowed Tx Rate(in bps) for
the port based on the Spectrum Management requirements for
XTUR in a particular spectral compliance configuration.
This object is the
Some measurement methods may have more than one range for
the TxRate. Min1TxRate and Max1TxRate will always have
the first range of values and the Min2TxRate and Max2TxRate
will have the second range if the method demands it."
::= { newSpectrumMgmtLineInfoEntry 6 }
newSpectrumMgmtXturMin1TxRate OBJECT-TYPE
SYNTAX Unsigned32
UNITS "bps"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This rate will be the min allowed Tx Rate based on the
spectrum management requirements for the XTUR. The
MinTxRate will be upper bounded by
'newSpectrumMgmtXturMax1TxRate' object.
Some measurement methods may have more than one range for
the TxRate. Min1TxRate and Max1TxRate will always have
the first range of values and the Min2TxRate and Max2TxRate
will have the second range if the method demands it."
::= { newSpectrumMgmtLineInfoEntry 7 }
newSpectrumMgmtXturMax2TxRate OBJECT-TYPE
SYNTAX Unsigned32
UNITS "bps"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This rate will be the max allowed Tx Rate(in bps) for
the port based on the Spectrum Management requirements for
XTUR in a particular spectral compliance configuration.
Some measurement methods may have more than one range for
the TxRate. Min1TxRate and Max1TxRate will always have
the first range of values and the Min2TxRate and Max2TxRate
will have the second range if the method demands it."
::= { newSpectrumMgmtLineInfoEntry 8 }
newSpectrumMgmtXturMin2TxRate OBJECT-TYPE
SYNTAX Unsigned32
UNITS "bps"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This rate will be the min allowed Tx Rate based on the
spectrum management requirements for the XTUR. The
MinTxRate will be upper bounded by
'newSpectrumMgmtXtucMax1TxRate' object.
Some measurement methods may have more than one range for
the TxRate. Min1TxRate and Max1TxRate will always have
the first range of values and the Min2TxRate and Max2TxRate
will have the second range if the method demands it."
::= { newSpectrumMgmtLineInfoEntry 9 }
newSpectrumMgmtXturMaxTxPower OBJECT-TYPE
SYNTAX INTEGER(-140..120)
UNITS "tenth dB"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The maximum transmit power at the ATUR (in tenth dB). This
value will be based on the spectrum management selection."
::= { newSpectrumMgmtLineInfoEntry 10 }
newSpectrumMgmtMinEWL OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The minimum value (in feet, if 'EWLUnits' is 'feet, or in
meters, if 'EWLUnits' is 'meters') that the 'ConfEWL'
object can accept. Together with the 'MaxEWL' object,
this object indicates the range of EWL when 'EWLUnits' is
either 'feet' or 'meters'.
Note : This object is valid only if the
'LoopMeasurementMethod' object is 'ewl'."
::= { newSpectrumMgmtLineInfoEntry 11 }
newSpectrumMgmtMaxEWL OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The maximum value (in feet, if 'EWLUnits' is 'feet, or in
meters, if 'EWLUnits' is 'meters') that the 'ConfEWL'
object can accept. Together with the 'MinEWL' object,
this object indicates the range of EWL when 'EWLUnits' is
either 'feet' or 'meters'.
Note : This object is valid only if the
'LoopMeasurementMethod' object is 'ewl'."
::= { newSpectrumMgmtLineInfoEntry 12 }
--
-- D E P R E C A T E D
--
-- The following objects are supported for the first version
-- of the shdsl cards. They are now deprecated and should not
-- be used for future products.
--
spectrumMgmtCountryCode OBJECT-TYPE
SYNTAX INTEGER {
usa(1),
uk(2)
}
MAX-ACCESS read-write
STATUS deprecated
DESCRIPTION
"This object selects which Spectrum Management
standard will be used on this device to calculate the
'allowed speeds' to comply with Spectrum Management.
Note:Spectrum Management must be Enabled for 'Country
Code' to take effect.
'USA' is the only valid selection for Region Setting
'Annex A', 'UK' will not be selectable.
'UK' for is the only valid selecton for Region Setting
'Annex B', 'USA' will not be selectable."
DEFVAL { usa }
::= { pdnSpecMgmtObjects 2 }
spectrumMgmtTable OBJECT-TYPE
SYNTAX SEQUENCE OF SpectrumMgmtEntry
MAX-ACCESS not-accessible
STATUS deprecated
DESCRIPTION
"The Spectrum Management Table."
::= { pdnSpecMgmtObjects 3 }
spectrumMgmtEntry OBJECT-TYPE
SYNTAX SpectrumMgmtEntry
MAX-ACCESS not-accessible
STATUS deprecated
DESCRIPTION
"An entry in the Spectrum Management table."
INDEX { ifIndex }
::= { spectrumMgmtTable 1 }
SpectrumMgmtEntry ::= SEQUENCE {
spectrumMgmtEWL Integer32,
spectrumMgmtLineLength INTEGER,
spectrumMgmtAllowedSpeedsMin1 Integer32,
spectrumMgmtAllowedSpeedsMax1 Integer32,
spectrumMgmtAllowedSpeedsMin2 Integer32,
spectrumMgmtAllowedSpeedsMax2 Integer32
}
spectrumMgmtEWL OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS deprecated
DESCRIPTION
"The Estimated Working Length [EWL(ft)]. The value
selected is the estimated length of the line in ft.
See the Deployment guideline Table below.
This value is usually specified by the carrier. This
value is only required if spectrumMgmt is Enabled and
the spectrumMgmtCountryCode selected is 'USA'."
::= { spectrumMgmtEntry 1 }
-- Estimated Working Length Deployment guidelines for G.shdsl
-- ---------------------------------------------------------
-- | Line Bit Rate(kbps) | Deployment guideline,EWL (ft) |
-- ---------------------------------------------------------
-- | LBR <= 592 | 15500 |
-- ---------------------------------------------------------
-- | 600 <= LBR <= 616 | 15000 |
-- | 624 <= LBR <= 648 | 14500 |
-- |---------------------------------------------------------|
-- | 656 <= LBR <= 688 | 14000 |
-- | 696 <= LBR <= 800 | 13500 |
-- |---------------------------------------------------------|
-- | 808 <= LBR <= 832 | 12500 |
-- | 840 <= LBR <= 896 | 12000 |
-- |---------------------------------------------------------|
-- | 904 <= LBR <= 952 | 13000 |
-- | 960 <= LBR <= 1000 | 12500 |
-- |---------------------------------------------------------|
-- | 1008 <= LBR <= 1088 | 12000 |
-- | 1096 <= LBR <= 1160 | 11500 |
-- |---------------------------------------------------------|
-- | 1168 <= LBR <= 1320 | 11000 |
-- | 1328 <= LBR <= 1472 | 10500 |
-- |---------------------------------------------------------|
-- | 1480 <= LBR <= 1536 | 10000 |
-- | 1544 <= LBR <= 1552 | 10500 |
-- |---------------------------------------------------------|
-- | 1560 <= LBR <= 1664 | 10000 |
-- | 1672 <= LBR <= 1880 | 9500 |
-- |---------------------------------------------------------|
-- | 1888 <= LBR <= 2008 | 9000 |
-- | 2016 <= LBR <= 2320 | 8500 |
-- ---------------------------------------------------------
-- Where LBR = Line Bit Rate
--
-- Note:Equivalent Working Length(EWL):EWL=L26+3(L24)/4,
-- where L26 is the total length of 26-gauge cable
-- in the loop excluding any bridged tap and L24 is
-- the total length of 19,22 or 24-gauge cable in
-- the loop excluding any bridged tap. All lengths
-- are in kilofeet (ft). This formula is suitable for
-- use with systems operating below 1.1MHz.
--
-- Note: Some EWL may have more then one range i.e., EWL
-- =12.5 Kft - ranges 192 Kbit/s to 832Kbits and 960 kbits
-- to 1000 kbits
--
spectrumMgmtAllowedSpeedsMin1 OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS deprecated
DESCRIPTION
"This rate will be the Minimum Line Bit Rate based
on the Line Length selected.
See the Deployment guideline Table above.
Example: EWL=12.5 this value may be 808kbps"
::= { spectrumMgmtEntry 2 }
spectrumMgmtAllowedSpeedsMax1 OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS deprecated
DESCRIPTION
"This rate will be the Maximum Line Bit Rate based
on the Line Length selected
See the Deployment guideline Table above.
Example: EWL=12.5 this value may be 832kbps"
::= { spectrumMgmtEntry 3 }
spectrumMgmtAllowedSpeedsMin2 OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS deprecated
DESCRIPTION
"This rate will be the Minimum Line Bit Rate based
on the Line Length selected.
See the Deployment guideline Table above.
Example: EWL=12.5 this value may be 960kbps"
::= { spectrumMgmtEntry 4 }
spectrumMgmtAllowedSpeedsMax2 OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS deprecated
DESCRIPTION
"This rate will be the Maximum Line Bit Rate based
on the Line Length selected.
See the Deployment guideline Table above.
Example: EWL=12.5 this value may be 1000kbps"
::= { spectrumMgmtEntry 5 }
spectrumMgmtLineLength OBJECT-TYPE
SYNTAX INTEGER {
short(1),
medium(2),
long(3)
}
MAX-ACCESS read-write
STATUS deprecated
DESCRIPTION
"This 'Line Length' feature is only required if the
SpectrumMgmt is Enabled and the spectrumMgmtCountryCode
selected is 'UK'.
'Short' Line Length from the exchange can support speeds
up to 2056 Kbps.
'Medium' Line Length can support speeds up to 1496 Kbps.
'Long' Line Length can suppport speeds up to 872 Kbps."
DEFVAL { short }
::= { spectrumMgmtEntry 6 }
--
-- C O N F O R M A N C E S T A T E M E N T S
--
pdnSpecMgmtConformance OBJECT IDENTIFIER
::= { pdnSpectrumMgmt 3 }
pdnSpecMgmtGroups OBJECT IDENTIFIER
::= { pdnSpecMgmtConformance 1 }
pdnSpecMgmtCompliances OBJECT IDENTIFIER
::= { pdnSpecMgmtConformance 2 }
--
-- C O M P L I A N C E S T A T E M E N T S
--
pdnSpecMgmtCompliance MODULE-COMPLIANCE
STATUS current
DESCRIPTION
"The compliance statement for SNMP entities that control
spectrum management on interfaces."
MODULE -- this module
MANDATORY-GROUPS {
pdnGeneralConfigGroup,
pdnLineInfoGroup
}
--
-- Groups
--
-- pdnEWLModeGroup,
-- pdnLoopLengthModeGroup,
-- pdnQuadModeGroup
--
-- are mutually exclusive; that is, at most one of these groups
-- is implemented for a particular DSL interface. If the
-- Loop Measurement Method is 'none', then none of these groups
-- should be implemented.
--
GROUP pdnEWLModeGroup
DESCRIPTION
"This group is mandatory for DSL interfaces whose
loop/line length measurement method is EWL.
i.e.the newSpectrumMgmtLoopMeasurementMethod object
is 'ewl'."
GROUP pdnLoopLengthModeGroup
DESCRIPTION
"This group is mandatory for DSL interfaces whose
loop/line length measurement method is LoopLength.
i.e.the newSpectrumMgmtLoopMeasurementMethod object
is 'loopLength'."
GROUP pdnQuadModeGroup
DESCRIPTION
"This group is mandatory for DSL interfaces whose
loop/line length measurement method is based on Quads.
i.e.the newSpectrumMgmtLoopMeasurementMethod object
is 'quadMode'."
OBJECT newSpectrumMgmtSelection
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
::= { pdnSpecMgmtCompliances 1 }
--
-- U N I T S O F C O N F O R M A N C E
--
-- Mandatory group
pdnGeneralConfigGroup OBJECT-GROUP
OBJECTS {
newSpectrumMgmtSelection,
newSpectrumMgmtMode,
newSpectrumMgmtLoopMeasurementMethod,
newSpectrumMgmtEWLUnits
}
STATUS current
DESCRIPTION
"A collection of general configuration objects
required for the spectrum management of
interfaces."
::= { pdnSpecMgmtGroups 1 }
-- Mandatory group
pdnLineInfoGroup OBJECT-GROUP
OBJECTS {
newSpectrumMgmtXtucMax1TxRate,
newSpectrumMgmtXtucMin1TxRate,
newSpectrumMgmtXtucMax2TxRate,
newSpectrumMgmtXtucMin2TxRate,
newSpectrumMgmtXtucMaxTxPower,
newSpectrumMgmtXturMax1TxRate,
newSpectrumMgmtXturMin1TxRate,
newSpectrumMgmtXturMax2TxRate,
newSpectrumMgmtXturMin2TxRate,
newSpectrumMgmtXturMaxTxPower,
newSpectrumMgmtMinEWL,
newSpectrumMgmtMaxEWL
}
STATUS current
DESCRIPTION
"A collection of objects providing information
regarding spectrum management of interfaces."
::= { pdnSpecMgmtGroups 2 }
--
-- Optional group
-- (pdnEWLModeGroup, pdnLineLoopModeGroup or pdnQuadModeGroup
-- should be implemented)
--
pdnEWLModeGroup OBJECT-GROUP
OBJECTS {
newSpectrumMgmtConfEWL,
newSpectrumMgmtMinEWL,
newSpectrumMgmtMaxEWL
}
STATUS current
DESCRIPTION
" A collection of configuration objects used to
control spectrum management of DSL intfs when
the measurement method is 'EWL'."
::= { pdnSpecMgmtGroups 3 }
--
-- Optional group
-- (pdnEWLModeGroup, pdnLineLoopModeGroup or pdnQuadModeGroup
-- should be implemented)
--
pdnLoopLengthModeGroup OBJECT-GROUP
OBJECTS {
newSpectrumMgmtConfLoopLength
}
STATUS current
DESCRIPTION
" A collection of configuration objects used to
control spectrum management of DSL intfs when
the measurement method is 'LoopLength' "
::= { pdnSpecMgmtGroups 4 }
--
-- Optional group
-- (pdnEWLModeGroup, pdnLineLoopModeGroup or pdnQuadModeGroup
-- should be implemented)
--
pdnQuadModeGroup OBJECT-GROUP
OBJECTS {
newSpectrumMgmtConfQuadMode
}
STATUS current
DESCRIPTION
"A collection of object(s) providing configuration
access and information specific to DSL interfaces
whose loop/line length measurement method is based on the
Quad configuration.
i.e.the newSpectrumMgmtLoopMeasurementMethod object
is 'quadMode'."
::= { pdnSpecMgmtGroups 5 }
--
-- D E P R E C A T E D G R O U P S
--
pdnSpectrumMgmtDeprecatedGroup OBJECT-GROUP
OBJECTS {
spectrumMgmtCountryCode,
spectrumMgmtEWL,
spectrumMgmtLineLength,
spectrumMgmtAllowedSpeedsMin1,
spectrumMgmtAllowedSpeedsMax1,
spectrumMgmtAllowedSpeedsMin2,
spectrumMgmtAllowedSpeedsMax2
}
STATUS deprecated
DESCRIPTION
" Deprecated objects "
::= { pdnSpecMgmtGroups 7 }
END