-- Copyright (C) 2000 Paradyne Corporation.
|
|
-- ATM M4 Extension Group
|
|
PDN-ATMM4EXT-MIB DEFINITIONS ::= BEGIN
|
|
|
|
IMPORTS
|
|
MODULE-IDENTITY , OBJECT-TYPE, OBJECT-IDENTITY,
|
|
Gauge32, TimeTicks
|
|
FROM SNMPv2-SMI
|
|
TEXTUAL-CONVENTION
|
|
FROM SNMPv2-TC
|
|
MODULE-COMPLIANCE, OBJECT-GROUP
|
|
FROM SNMPv2-CONF
|
|
pdnAtm
|
|
FROM PDN-HEADER-MIB
|
|
atmfM4VpTestEntry, atmfM4VcTestEntry, atmfM4TcProtoCurrEntry, atmfM4TcProtoHistEntry
|
|
FROM ATM-FORUM-SNMP-M4-MIB
|
|
ifIndex
|
|
FROM IF-MIB;
|
|
|
|
-- ===============================================================
|
|
--
|
|
-- Extentions to the ATM Forum M4 Mib
|
|
--
|
|
-- ===============================================================
|
|
|
|
pdnAtmfM4ExtMIB MODULE-IDENTITY
|
|
LAST-UPDATED "200103080000Z"
|
|
ORGANIZATION "Paradyne Corporation
|
|
MIB Working Group"
|
|
CONTACT-INFO
|
|
"Paradyne Corporation
|
|
8545 126th Avenue North
|
|
Largo, FL 33773
|
|
www.paradyne.com
|
|
|
|
General Comments to: mibwg_team@eng.paradyne.com"
|
|
|
|
DESCRIPTION
|
|
"This MIB Module extends the ATM-FORUM-SNMP-M4-MI defined
|
|
in the Atm Forums M4 Mib
|
|
"
|
|
REVISION "200208150000Z"
|
|
DESCRIPTION "P. Easwar
|
|
o Added New Table pdnAtmfM4VpLoopbackTestTable.
|
|
"
|
|
|
|
REVISION "200103080000Z"
|
|
DESCRIPTION "R.A.Bowhall
|
|
o Added error code of adminStatusDisabled(8).
|
|
"
|
|
|
|
REVISION "200009260000Z"
|
|
DESCRIPTION "R. Steinberger
|
|
o Added size to pdnAtmfM4Vc1CellLoopReportedLocation.
|
|
"
|
|
REVISION "200009220000Z"
|
|
DESCRIPTION "R. Steinberger
|
|
o Added error code of testTimeOut(7).
|
|
o Added description of use of pdnAtmfM4Vc1CellLoopTable
|
|
o Changed pdnAtmfM4Vc1CellLoopReportedLocation type to
|
|
meet actual M4 definition of OCTET STRING(SIZE(16))
|
|
o Added the pdnAtmfM4LoopbackLocationTable
|
|
"
|
|
REVISION "200009210000Z"
|
|
DESCRIPTION "J.Strain
|
|
o Added E2E and SEG as Multiple OAM Cell Tests
|
|
o documented mapping of atmfM4VcTestType to the corresponding
|
|
atmfM4VcTestCode results table
|
|
"
|
|
REVISION "200009080000Z"
|
|
DESCRIPTION "R. Steinberger
|
|
o Cleaned tabs throughout document.
|
|
o Fixed naming convention.
|
|
o Added pdnAtmfM4Vc1CellLoopTable for ATM OAM loopbacks
|
|
that send only single test cell.
|
|
o Added conformance section.
|
|
"
|
|
REVISION "200006290000Z"
|
|
DESCRIPTION "Z. Pan
|
|
o added augmented atmfM4VcTestTable for ATM OAM loopback test.
|
|
"
|
|
::= { pdnAtm 6 }
|
|
|
|
pdnAtmfM4ExtObjects OBJECT IDENTIFIER ::= { pdnAtmfM4ExtMIB 1 }
|
|
pdnAtmfM4ExtTraps OBJECT IDENTIFIER ::= { pdnAtmfM4ExtMIB 2 }
|
|
pdnAtmfM4ExtConformance OBJECT IDENTIFIER ::= { pdnAtmfM4ExtMIB 3 }
|
|
pdnAtmfM4ExtTrapPrefix OBJECT IDENTIFIER ::= { pdnAtmfM4ExtTraps 0 }
|
|
--
|
|
-- Textual Conventions Specific to this MIB Module
|
|
--
|
|
PdnAtmfM4TestErrorCode ::= TEXTUAL-CONVENTION
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The specific error codes related to attempting to run a test. The
|
|
codes have the following meanings:
|
|
|
|
noError(0) -- No Error Occurred
|
|
badIfIndex(1) -- Specified interface does not exist
|
|
noVccFound(2) -- The Vcc does not exist on the interface
|
|
notOwner(3) -- Not the current owner of the test
|
|
noResourceAvailable(4) -- Device memory allocation failure
|
|
noLoopbackAllocated(5) -- Could not start the test
|
|
testCompleted(6) -- Test completed or stopped normally
|
|
testTimeOut(7) -- Test unsuccessfully due to timeout
|
|
adminStatusDisabled(8) -- ifAdminStatus is Disabled
|
|
"
|
|
SYNTAX INTEGER {
|
|
noError(0),
|
|
badIfIndex(1),
|
|
noVccFound(2),
|
|
notOwner(3),
|
|
noResourceAvailable(4),
|
|
noLoopbackAllocated(5),
|
|
testCompleted(6),
|
|
testTimeOut(7),
|
|
adminStatusDisabled(8)
|
|
}
|
|
|
|
--
|
|
-- ATM TC layer current and historical fifteen-minute interval statistics
|
|
-- pdnAtmfM4TcProtoCurrExtTable and pdnAtmfM4TcProtoHistExtTable
|
|
--
|
|
|
|
-- ATM TC layer current fifteen-minute interval data statistics
|
|
|
|
pdnAtmfM4TcProtoCurrExtTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF PdnAtmfM4TcProtoCurrExtEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The Paradyne Extension to the atmfM4TcProtoCurrTable of the
|
|
ATM-FORUM-SNMP-M4-MIB."
|
|
::= { pdnAtmfM4ExtObjects 1 }
|
|
|
|
pdnAtmfM4TcProtoCurrExtEntry OBJECT-TYPE
|
|
SYNTAX PdnAtmfM4TcProtoCurrExtEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The Paradyne Extension to the atmfM4TcProtoCurrTable of the
|
|
ATM-FORUM-SNMP-M4-MIB."
|
|
AUGMENTS { atmfM4TcProtoCurrEntry }
|
|
::= { pdnAtmfM4TcProtoCurrExtTable 1 }
|
|
|
|
PdnAtmfM4TcProtoCurrExtEntry ::= SEQUENCE {
|
|
pdnAtmfM4TcProtoCurrCellIns Gauge32,
|
|
pdnAtmfM4TcProtoCurrCellOuts Gauge32,
|
|
pdnAtmfM4TcProtoCurrInDiscards Gauge32,
|
|
pdnAtmfM4TcProtoCurrOutDiscards Gauge32,
|
|
pdnAtmfM4TcProtoCurrLCDEvents Gauge32,
|
|
pdnAtmfM4TcProtoCurrUnknownCells Gauge32,
|
|
pdnAtmfM4TcProtoCurrCorrectedHEC Gauge32
|
|
}
|
|
|
|
pdnAtmfM4TcProtoCurrCellIns OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of ATM cells received on this interface since the
|
|
start of this interval"
|
|
::= { pdnAtmfM4TcProtoCurrExtEntry 1 }
|
|
|
|
pdnAtmfM4TcProtoCurrCellOuts OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of ATM cells sent on this interface since the
|
|
start of this interval"
|
|
::= { pdnAtmfM4TcProtoCurrExtEntry 2 }
|
|
|
|
pdnAtmfM4TcProtoCurrInDiscards OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of RX ATM cells dropped on this interface since the
|
|
start of this interval"
|
|
::= { pdnAtmfM4TcProtoCurrExtEntry 3 }
|
|
|
|
pdnAtmfM4TcProtoCurrOutDiscards OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of TX ATM cells dropped on this interface since the
|
|
start of this interval"
|
|
::= { pdnAtmfM4TcProtoCurrExtEntry 4 }
|
|
|
|
pdnAtmfM4TcProtoCurrLCDEvents OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of Loss of Cell Delineation (LCD) event occurred
|
|
on this interface since the start of this interval"
|
|
::= { pdnAtmfM4TcProtoCurrExtEntry 5 }
|
|
|
|
pdnAtmfM4TcProtoCurrUnknownCells OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of unknown Cells received on this interface since
|
|
the start of this interval"
|
|
::= { pdnAtmfM4TcProtoCurrExtEntry 6 }
|
|
|
|
pdnAtmfM4TcProtoCurrCorrectedHEC OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of Cell with corrected HEC received on this interface
|
|
since the start of this interval"
|
|
::= { pdnAtmfM4TcProtoCurrExtEntry 7 }
|
|
|
|
--
|
|
-- ATM TC layer historical fifteen-minute interval statistics
|
|
-- (per interface and time interval)
|
|
--
|
|
|
|
pdnAtmfM4TcProtoHistExtTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF PdnAtmfM4TcProtoHistExtEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The Paradyne Extension to the atmfM4TcProtoHistTable of the
|
|
ATM-FORUM-SNMP-M4-MIB."
|
|
::= { pdnAtmfM4ExtObjects 2 }
|
|
|
|
pdnAtmfM4TcProtoHistExtEntry OBJECT-TYPE
|
|
SYNTAX PdnAtmfM4TcProtoHistExtEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The Paradyne Extension to the atmfM4TcProtoHistTable of the
|
|
ATM-FORUM-SNMP-M4-MIB."
|
|
AUGMENTS { atmfM4TcProtoHistEntry }
|
|
::= { pdnAtmfM4TcProtoHistExtTable 1 }
|
|
|
|
PdnAtmfM4TcProtoHistExtEntry ::= SEQUENCE {
|
|
pdnAtmfM4TcProtoHistCellIns Gauge32,
|
|
pdnAtmfM4TcProtoHistCellOuts Gauge32,
|
|
pdnAtmfM4TcProtoHistInDiscards Gauge32,
|
|
pdnAtmfM4TcProtoHistOutDiscards Gauge32,
|
|
pdnAtmfM4TcProtoHistLCDEvents Gauge32,
|
|
pdnAtmfM4TcProtoHistUnknownCells Gauge32,
|
|
pdnAtmfM4TcProtoHistCorrectedHEC Gauge32
|
|
}
|
|
|
|
pdnAtmfM4TcProtoHistCellIns OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of ATM cells received on this interface
|
|
during this interval"
|
|
::= { pdnAtmfM4TcProtoHistExtEntry 1 }
|
|
|
|
pdnAtmfM4TcProtoHistCellOuts OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of ATM cells sent on this interface during
|
|
this interval"
|
|
::= { pdnAtmfM4TcProtoHistExtEntry 2 }
|
|
|
|
pdnAtmfM4TcProtoHistInDiscards OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of RX ATM cells dropped on this interface
|
|
during this interval"
|
|
::= { pdnAtmfM4TcProtoHistExtEntry 3 }
|
|
|
|
pdnAtmfM4TcProtoHistOutDiscards OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of TX ATM cells dropped on this interface
|
|
during this interval"
|
|
::= { pdnAtmfM4TcProtoHistExtEntry 4 }
|
|
|
|
pdnAtmfM4TcProtoHistLCDEvents OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of Loss of Cell Delineation (LCD) event occurred
|
|
on this interface during this interval"
|
|
::= { pdnAtmfM4TcProtoHistExtEntry 5 }
|
|
|
|
pdnAtmfM4TcProtoHistUnknownCells OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of unknown Cells received on this interface since
|
|
the start of this interval"
|
|
::= { pdnAtmfM4TcProtoHistExtEntry 6 }
|
|
|
|
pdnAtmfM4TcProtoHistCorrectedHEC OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of Cell with corrected HEC received on this interface
|
|
during this interval"
|
|
::= { pdnAtmfM4TcProtoHistExtEntry 7 }
|
|
|
|
|
|
--
|
|
-- The following object defines a group of OAM test types.
|
|
-- This group is to contain any Paradyne Specific OAM test
|
|
--
|
|
|
|
pdnAtmfM4TestTypes OBJECT IDENTIFIER ::= { pdnAtmfM4ExtObjects 3 }
|
|
|
|
--
|
|
-- The following OID is defined to initiate continuous Segment OAM Cells
|
|
--
|
|
|
|
pdnAtmfM4TestOAMLoopbackSegMultiCell OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This identifies an OAM Loopback Test on a VPL, VPC,
|
|
VCL, or VCC termination point, using a segment OAM
|
|
cell.
|
|
|
|
The test type must have appended to it a code that uniquely
|
|
identifies an intermediate point responsible for looping
|
|
back the cell. If this is absent, the loopback is performed
|
|
at the end of the segment or connection.
|
|
|
|
E.g., the OID { pdnAtmfM4TestOAMLoopbackSegMultiCell 5 } identifies
|
|
that the loopback should be performed at the intermediate
|
|
point labeled 5."
|
|
::= { pdnAtmfM4TestTypes 1 }
|
|
|
|
--
|
|
-- The following OID is defined to initiate continuous End to End OAM cells
|
|
--
|
|
|
|
pdnAtmfM4TestOAMLoopbackE2EMultiCell OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This identifies an OAM Loopback Test on a VPL, VPC,
|
|
VCL, or VCC termination point, using an end-to-end OAM
|
|
cell."
|
|
::= { pdnAtmfM4TestTypes 2 }
|
|
|
|
--
|
|
-- Test Code to Test Results Matrix
|
|
--
|
|
-- atmfM4VcTestType atmfM4VcTestCode Result Table
|
|
-- ________________ _____________________________
|
|
--
|
|
-- atmfM4TestOAMLoopbackSeg(standard is a single cell test)
|
|
-- pdnAtmfM4Vc1CellLoopTable
|
|
-- atmfM4TestOAMLoopbackE2E(standard is a single cell test)
|
|
-- pdnAtmfM4Vc1CellLoopTable
|
|
--
|
|
-- pdnAtmfM4TestOAMLoopbackSegMultiCell
|
|
-- pdnAtmfM4VcLoopbackTestTable
|
|
-- pdnAtmfM4TestOAMLoopbackE2EMultiCell
|
|
-- pdnAtmfM4VcLoopbackTestTable
|
|
--
|
|
|
|
--
|
|
-- OAM Loopback test (multiple cell) detailed results table
|
|
--
|
|
|
|
pdnAtmfM4VcLoopbackTestTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF PdnAtmfM4VcLoopbackTestEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This table contains input and results for OAM loopback
|
|
tests. There can be only one test running per ATM VCC
|
|
This table should be used in conjunction with atmfM4VcTestTable
|
|
with all the semantics of atmfM4VcTestTable."
|
|
::= { pdnAtmfM4ExtObjects 4 }
|
|
|
|
pdnAtmfM4VcLoopbackTestEntry OBJECT-TYPE
|
|
SYNTAX PdnAtmfM4VcLoopbackTestEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry containing objects for test results
|
|
for ATM OAM loopback test"
|
|
AUGMENTS { atmfM4VcTestEntry }
|
|
::= { pdnAtmfM4VcLoopbackTestTable 1 }
|
|
|
|
PdnAtmfM4VcLoopbackTestEntry ::=
|
|
SEQUENCE {
|
|
pdnAtmfM4VcLoopbackTestElpsTime TimeTicks,
|
|
pdnAtmfM4VcLoopbackTestCellsSent Gauge32,
|
|
pdnAtmfM4VcLoopbackTestCellsRcvd Gauge32,
|
|
pdnAtmfM4VcLoopbackTestMinRTDelay Gauge32,
|
|
pdnAtmfM4VcLoopbackTestMaxRTDelay Gauge32,
|
|
pdnAtmfM4VcLoopbackTestAvgRTDelay Gauge32,
|
|
pdnAtmfM4VcLoopbackTestErrorCode PdnAtmfM4TestErrorCode
|
|
}
|
|
|
|
pdnAtmfM4VcLoopbackTestElpsTime OBJECT-TYPE
|
|
SYNTAX TimeTicks
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object contains the time that has elapsed since the test started."
|
|
::= { pdnAtmfM4VcLoopbackTestEntry 1 }
|
|
|
|
pdnAtmfM4VcLoopbackTestCellsSent OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object specifies a count of the number of test cells that
|
|
have been sent. The value of this object stops increasing
|
|
when it reaches its maximum value."
|
|
::= { pdnAtmfM4VcLoopbackTestEntry 2 }
|
|
|
|
pdnAtmfM4VcLoopbackTestCellsRcvd OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object specifies a count of the number of test cells that
|
|
have been received. The value of this object stops increasing
|
|
when it reaches its maximum value."
|
|
::= { pdnAtmfM4VcLoopbackTestEntry 3 }
|
|
|
|
pdnAtmfM4VcLoopbackTestMinRTDelay OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
UNITS "milliseconds"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object contains the value of the shortest round trip delay
|
|
since the test has been started. It is calculated only on the cells
|
|
that have been received. Cells that were dropped are not counted."
|
|
::= { pdnAtmfM4VcLoopbackTestEntry 4 }
|
|
|
|
pdnAtmfM4VcLoopbackTestMaxRTDelay OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
UNITS "milliseconds"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object contains the value of the longest round trip delay
|
|
since the test has been started. It is calculated only on the cells
|
|
that have been received. Cells that were dropped are not counted."
|
|
::= { pdnAtmfM4VcLoopbackTestEntry 5 }
|
|
|
|
pdnAtmfM4VcLoopbackTestAvgRTDelay OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
UNITS "milliseconds"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object contains the value of the average round trip delay
|
|
since the test has been started. It is calculated only on the cells
|
|
that have been received. Cells that were dropped are not counted."
|
|
::= { pdnAtmfM4VcLoopbackTestEntry 6 }
|
|
|
|
pdnAtmfM4VcLoopbackTestErrorCode OBJECT-TYPE
|
|
SYNTAX PdnAtmfM4TestErrorCode
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object contains the specific error code on the test result."
|
|
::= { pdnAtmfM4VcLoopbackTestEntry 7 }
|
|
|
|
--
|
|
-- Single Cell OAM Loopback test detailed results
|
|
--
|
|
-- This table contains results for single cell OAM tests that are not
|
|
-- of a broadcast variety.
|
|
--
|
|
-- Recommended Use:
|
|
--
|
|
-- 1) The NMS will start a test using the M4 MIB's atmfM4VcTestTable.
|
|
-- 2) Upon starting the test, the agent will put the corresponding OID
|
|
-- of a row in this table into the atmfM4VcTestCode object.
|
|
-- 3) When the value of atmfM4VcTestResult is not equal to inProgress(3),
|
|
-- the values contained in this table should be read.
|
|
--
|
|
pdnAtmfM4Vc1CellLoopTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF PdnAtmfM4Vc1CellLoopEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This table contains input and results for single cell OAM
|
|
loopback tests. There can be only one test running per ATM VCC
|
|
This table should be used in conjunction with atmfM4VcTestTable
|
|
with all the semantics of atmfM4VcTestTable."
|
|
::= { pdnAtmfM4ExtObjects 5 }
|
|
|
|
pdnAtmfM4Vc1CellLoopEntry OBJECT-TYPE
|
|
SYNTAX PdnAtmfM4Vc1CellLoopEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry containing objects for test results
|
|
for a single cell ATM OAM loopback test"
|
|
AUGMENTS { atmfM4VcTestEntry }
|
|
::= { pdnAtmfM4Vc1CellLoopTable 1 }
|
|
|
|
PdnAtmfM4Vc1CellLoopEntry ::=
|
|
SEQUENCE {
|
|
pdnAtmfM4Vc1CellLoopRTDelay Gauge32,
|
|
pdnAtmfM4Vc1CellLoopReportedLocation OCTET STRING,
|
|
pdnAtmfM4Vc1CellLoopErrorCode PdnAtmfM4TestErrorCode
|
|
}
|
|
|
|
pdnAtmfM4Vc1CellLoopRTDelay OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
UNITS "milliseconds"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object contains the value of the round trip delay of the
|
|
the test cell. A value of zero indicates that no cell has been
|
|
received."
|
|
::= { pdnAtmfM4Vc1CellLoopEntry 1 }
|
|
|
|
pdnAtmfM4Vc1CellLoopReportedLocation OBJECT-TYPE
|
|
SYNTAX OCTET STRING(SIZE(16))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object contains the value of the location identifier
|
|
reported by the received cell."
|
|
::= { pdnAtmfM4Vc1CellLoopEntry 2 }
|
|
|
|
pdnAtmfM4Vc1CellLoopErrorCode OBJECT-TYPE
|
|
SYNTAX PdnAtmfM4TestErrorCode
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object contains the specific error code on the test result."
|
|
::= { pdnAtmfM4Vc1CellLoopEntry 3 }
|
|
|
|
--
|
|
-- OAM Segment Loopback Location Code
|
|
--
|
|
pdnAtmfM4LoopbackLocationTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF PdnAtmfM4LoopbackLocationEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This table contains the ATM OAM loopback location codes
|
|
for ATM cell layer interfaces."
|
|
::= { pdnAtmfM4ExtObjects 6 }
|
|
|
|
pdnAtmfM4LoopbackLocationEntry OBJECT-TYPE
|
|
SYNTAX PdnAtmfM4LoopbackLocationEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry containing objects for ATM OAM loopback locations."
|
|
INDEX { ifIndex }
|
|
::= { pdnAtmfM4LoopbackLocationTable 1 }
|
|
|
|
PdnAtmfM4LoopbackLocationEntry ::=
|
|
SEQUENCE {
|
|
pdnAtmfM4LoopbackLocationCode OCTET STRING
|
|
}
|
|
|
|
pdnAtmfM4LoopbackLocationCode OBJECT-TYPE
|
|
SYNTAX OCTET STRING(SIZE(16))
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object contains the value of ATM OAM Loopback Location Code"
|
|
::= { pdnAtmfM4LoopbackLocationEntry 1 }
|
|
|
|
pdnAtmfM4VpLoopbackTestTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF PdnAtmfM4VpLoopbackTestEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This table contains input and results for OAM loopback
|
|
tests. There can be only one test running per ATM VPC
|
|
This table should be used in conjunction with atmfM4VpTestTable
|
|
with all the semantics of atmfM4VpTestTable."
|
|
::= { pdnAtmfM4ExtObjects 7 }
|
|
|
|
pdnAtmfM4VpLoopbackTestEntry OBJECT-TYPE
|
|
SYNTAX PdnAtmfM4VpLoopbackTestEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry containing objects for test results
|
|
for ATM OAM loopback test"
|
|
AUGMENTS { atmfM4VpTestEntry }
|
|
::= { pdnAtmfM4VpLoopbackTestTable 1 }
|
|
|
|
PdnAtmfM4VpLoopbackTestEntry ::=
|
|
SEQUENCE {
|
|
pdnAtmfM4VpLoopbackTestElpsTime TimeTicks,
|
|
pdnAtmfM4VpLoopbackTestCellsSent Gauge32,
|
|
pdnAtmfM4VpLoopbackTestCellsRcvd Gauge32,
|
|
pdnAtmfM4VpLoopbackTestMinRTDelay Gauge32,
|
|
pdnAtmfM4VpLoopbackTestMaxRTDelay Gauge32,
|
|
pdnAtmfM4VpLoopbackTestAvgRTDelay Gauge32,
|
|
pdnAtmfM4VpLoopbackTestErrorCode PdnAtmfM4TestErrorCode
|
|
}
|
|
|
|
pdnAtmfM4VpLoopbackTestElpsTime OBJECT-TYPE
|
|
SYNTAX TimeTicks
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object contains the time that has elapsed since the test started."
|
|
::= { pdnAtmfM4VpLoopbackTestEntry 1 }
|
|
|
|
pdnAtmfM4VpLoopbackTestCellsSent OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object specifies a count of the number of test cells that
|
|
have been sent. The value of this object stops increasing
|
|
when it reaches its maximum value."
|
|
::= { pdnAtmfM4VpLoopbackTestEntry 2 }
|
|
|
|
pdnAtmfM4VpLoopbackTestCellsRcvd OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object specifies a count of the number of test cells that
|
|
have been received. The value of this object stops increasing
|
|
when it reaches its maximum value."
|
|
::= { pdnAtmfM4VpLoopbackTestEntry 3 }
|
|
|
|
pdnAtmfM4VpLoopbackTestMinRTDelay OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
UNITS "milliseconds"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object contains the value of the shortest round trip delay
|
|
since the test has been started. It is calculated only on the cells
|
|
that have been received. Cells that were dropped are not counted."
|
|
::= { pdnAtmfM4VpLoopbackTestEntry 4 }
|
|
|
|
pdnAtmfM4VpLoopbackTestMaxRTDelay OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
UNITS "milliseconds"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object contains the value of the longest round trip delay
|
|
since the test has been started. It is calculated only on the cells
|
|
that have been received. Cells that were dropped are not counted."
|
|
::= { pdnAtmfM4VpLoopbackTestEntry 5 }
|
|
|
|
pdnAtmfM4VpLoopbackTestAvgRTDelay OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
UNITS "milliseconds"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object contains the value of the average round trip delay
|
|
since the test has been started. It is calculated only on the cells
|
|
that have been received. Cells that were dropped are not counted."
|
|
::= { pdnAtmfM4VpLoopbackTestEntry 6 }
|
|
|
|
pdnAtmfM4VpLoopbackTestErrorCode OBJECT-TYPE
|
|
SYNTAX PdnAtmfM4TestErrorCode
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object contains the specific error code on the test result."
|
|
::= { pdnAtmfM4VpLoopbackTestEntry 7 }
|
|
|
|
-- Conformance Information
|
|
|
|
pdnAtmfM4Groups OBJECT IDENTIFIER ::= { pdnAtmfM4ExtConformance 1 }
|
|
pdnAtmfM4Compliances OBJECT IDENTIFIER ::= { pdnAtmfM4ExtConformance 2 }
|
|
|
|
pdnAtmfM4Compliance MODULE-COMPLIANCE
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The compliance statement for SNMP entities which support
|
|
the ATM M4 extensions."
|
|
MODULE
|
|
GROUP pdnAtmfM4LoopbackLocationGroup
|
|
DESCRIPTION
|
|
"The conditional objects in the Loopback Location Group."
|
|
OBJECT pdnAtmfM4LoopbackLocationCode
|
|
MIN-ACCESS read-only
|
|
DESCRIPTION
|
|
"Write access is not required"
|
|
::= { pdnAtmfM4Compliances 1 }
|
|
|
|
--
|
|
-- Units of Conformance
|
|
--
|
|
|
|
pdnAtmfM4TcCurrGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
pdnAtmfM4TcProtoCurrCellIns,
|
|
pdnAtmfM4TcProtoCurrCellOuts,
|
|
pdnAtmfM4TcProtoCurrInDiscards,
|
|
pdnAtmfM4TcProtoCurrOutDiscards,
|
|
pdnAtmfM4TcProtoCurrLCDEvents,
|
|
pdnAtmfM4TcProtoCurrUnknownCells,
|
|
pdnAtmfM4TcProtoCurrCorrectedHEC
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The objects in the ATM TC layer current table."
|
|
::= { pdnAtmfM4Groups 1 }
|
|
|
|
pdnAtmfM4TcHistGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
pdnAtmfM4TcProtoHistCellIns,
|
|
pdnAtmfM4TcProtoHistCellOuts,
|
|
pdnAtmfM4TcProtoHistInDiscards,
|
|
pdnAtmfM4TcProtoHistOutDiscards,
|
|
pdnAtmfM4TcProtoHistLCDEvents,
|
|
pdnAtmfM4TcProtoHistUnknownCells,
|
|
pdnAtmfM4TcProtoHistCorrectedHEC
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The objects in the ATM TC layer history table."
|
|
::= { pdnAtmfM4Groups 2 }
|
|
|
|
pdnAtmfM4VcLoopbackTestGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
pdnAtmfM4VcLoopbackTestElpsTime,
|
|
pdnAtmfM4VcLoopbackTestCellsSent,
|
|
pdnAtmfM4VcLoopbackTestCellsRcvd,
|
|
pdnAtmfM4VcLoopbackTestMinRTDelay,
|
|
pdnAtmfM4VcLoopbackTestMaxRTDelay,
|
|
pdnAtmfM4VcLoopbackTestAvgRTDelay,
|
|
pdnAtmfM4VcLoopbackTestErrorCode
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The objects in the ATM OAM Loopback Test (multiple cell) table for ATM VCC."
|
|
::= { pdnAtmfM4Groups 3 }
|
|
|
|
pdnAtmfM4Vc1CellLoopGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
pdnAtmfM4Vc1CellLoopRTDelay,
|
|
pdnAtmfM4Vc1CellLoopReportedLocation,
|
|
pdnAtmfM4Vc1CellLoopErrorCode
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The objects in the ATM Single Cell OAM Loopback Test table."
|
|
::= { pdnAtmfM4Groups 4 }
|
|
|
|
pdnAtmfM4LoopbackLocationGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
pdnAtmfM4LoopbackLocationCode
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The objects in the ATM Loopback Location table."
|
|
::= { pdnAtmfM4Groups 5 }
|
|
|
|
pdnAtmfM4VpLoopbackTestGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
pdnAtmfM4VpLoopbackTestElpsTime,
|
|
pdnAtmfM4VpLoopbackTestCellsSent,
|
|
pdnAtmfM4VpLoopbackTestCellsRcvd,
|
|
pdnAtmfM4VpLoopbackTestMinRTDelay,
|
|
pdnAtmfM4VpLoopbackTestMaxRTDelay,
|
|
pdnAtmfM4VpLoopbackTestAvgRTDelay,
|
|
pdnAtmfM4VpLoopbackTestErrorCode
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The objects in the ATM OAM Loopback Test (multiple cell) table for ATM VPC."
|
|
::= { pdnAtmfM4Groups 6 }
|
|
END |