RC-CB-SWITCH-FABRIC-MIB DEFINITIONS ::= BEGIN
|
|
|
|
IMPORTS
|
|
MODULE-IDENTITY, OBJECT-TYPE, Integer32, Counter32, Counter64, IpAddress, Unsigned32
|
|
FROM SNMPv2-SMI
|
|
TruthValue, RowStatus, TEXTUAL-CONVENTION, DisplayString
|
|
FROM SNMPv2-TC
|
|
InterfaceIndex
|
|
FROM IF-MIB
|
|
rcCobaltBlue
|
|
FROM RAPID-CITY
|
|
InetAddressType, InetAddress
|
|
FROM INET-ADDRESS-MIB;
|
|
|
|
rcCobaltBlueMib MODULE-IDENTITY
|
|
LAST-UPDATED "201910090000Z"
|
|
ORGANIZATION "Nortel Networks, Enterprise Data"
|
|
CONTACT-INFO "Yu-Ten Lee
|
|
Postal: Nortel Networks, Inc.
|
|
4655 Great America Parkway
|
|
Santa Clara, CA 95052-8185
|
|
|
|
Tel: 408-495-2560
|
|
Fax: 408-495-6680
|
|
E-mail: ylee@baynetworks.com"
|
|
|
|
DESCRIPTION "Enterprise Data MIB for the CB product family."
|
|
|
|
REVISION "201910090000Z" -- 09 October 2019
|
|
DESCRIPTION "Version 11: Add cpu(4)-unknown(24) under rc2kCardTemperatureZoneInfo
|
|
to cover temperature sensors on all VSP platforms
|
|
(Prem)"
|
|
|
|
REVISION "201901080000Z" -- 08 Jan 2019
|
|
DESCRIPTION "Version 10: Increased the range of rcFanTrayId from 1..2 to 1..6
|
|
VOSS 8.0 (Prem)"
|
|
|
|
REVISION "201706190000Z" -- 19 June 2017
|
|
DESCRIPTION "Version 9: Increased the range of rcCbQe2kSerdesLinkId
|
|
from 1..640 to 1..768.
|
|
Requested by Amjadkhan Pathan (submit 34992)
|
|
for VSP9000 (prempa)"
|
|
|
|
REVISION "201402140000Z" -- 14 February 2014
|
|
DESCRIPTION "Version 8: Added rc2kCardZoneTemperature and
|
|
rc2kCardTemperatureZoneInfo."
|
|
|
|
REVISION "201401130000Z" -- 13 January 2014
|
|
DESCRIPTION "Version 7: Added rc2kCardShutDownReason."
|
|
|
|
REVISION "201310110000Z" -- 11 October 2013
|
|
DESCRIPTION "Version 6: Added types to IMPORTS."
|
|
|
|
REVISION "201301180000Z" -- 18 January 2013
|
|
DESCRIPTION "Version 5: Added rcSlotPowerStatus."
|
|
|
|
REVISION "201102070000Z" -- 7 February 2011
|
|
DESCRIPTION "Version 4: Added rcLoginHostAddressType,
|
|
rcLoginHostInetAddress."
|
|
|
|
REVISION "201009160000Z" -- 16 September 2010
|
|
DESCRIPTION "Version 3: Replace most objects with VSP implementation."
|
|
|
|
REVISION "200912100000Z" -- 10 December 2009
|
|
DESCRIPTION "Version 2: Add rcCbProfileType to rcCbSwitchFabricScalars group"
|
|
|
|
REVISION "200804280000Z" -- 28 April 2008
|
|
DESCRIPTION "Version 1: Initial version"
|
|
|
|
::= { rcCobaltBlue 1 }
|
|
|
|
DeviceStatus ::= TEXTUAL-CONVENTION
|
|
STATUS current
|
|
DESCRIPTION "Standard card states for slotted chassis based products"
|
|
SYNTAX INTEGER {
|
|
invalid(1),
|
|
down(2),
|
|
up(3),
|
|
disabled(4)
|
|
}
|
|
|
|
SfDeviceMode ::= TEXTUAL-CONVENTION
|
|
STATUS current
|
|
DESCRIPTION "Mode of given Fast SE Device either BME or SE"
|
|
SYNTAX INTEGER {
|
|
other (1),
|
|
bme(2),
|
|
se(3)
|
|
}
|
|
|
|
--
|
|
-- Object groups within the Cobalt Blue MIB
|
|
--
|
|
|
|
rcCbNotifications OBJECT IDENTIFIER ::= { rcCobaltBlueMib 0 }
|
|
rcCbObjects OBJECT IDENTIFIER ::= { rcCobaltBlueMib 1 }
|
|
|
|
rcCbSwitchFabric OBJECT IDENTIFIER ::= { rcCbObjects 1 }
|
|
rcCbSwitchFabricScalars OBJECT IDENTIFIER ::= { rcCbSwitchFabric 1 }
|
|
|
|
rcCbSwitchFabricStats OBJECT IDENTIFIER ::= { rcCbSwitchFabricScalars 1 }
|
|
|
|
rcCbSwitchFabricDropPrec1AcceptedPackets OBJECT-TYPE
|
|
SYNTAX Counter64
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Accepted number of packets from drop precedence 1. The drop precedence is a function of the front end policer."
|
|
::= { rcCbSwitchFabricStats 1 }
|
|
|
|
rcCbSwitchFabricDropPrec1AcceptedBytes OBJECT-TYPE
|
|
SYNTAX Counter64
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Accepted number of bytes from drop precedence 1"
|
|
::= { rcCbSwitchFabricStats 2 }
|
|
|
|
rcCbSwitchFabricDropPrec1CongestionMarkedPackets OBJECT-TYPE
|
|
SYNTAX Counter64
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Congestion marked number of packets from drop precedence 1."
|
|
::= { rcCbSwitchFabricStats 3 }
|
|
|
|
rcCbSwitchFabricDropPrec1CongestionMarkedBytes OBJECT-TYPE
|
|
SYNTAX Counter64
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Congestion marked number of bytes from drop precedence 1."
|
|
::= { rcCbSwitchFabricStats 4 }
|
|
|
|
rcCbSwitchFabricDropPrec1DiscardDroppedPackets OBJECT-TYPE
|
|
SYNTAX Counter64
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "WRED dropped number of packets from drop precedence 1."
|
|
::= { rcCbSwitchFabricStats 5 }
|
|
|
|
rcCbSwitchFabricDropPrec1DiscardDroppedBytes OBJECT-TYPE
|
|
SYNTAX Counter64
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "WRED dropped number of bytes from drop precedence 1."
|
|
::= { rcCbSwitchFabricStats 6 }
|
|
|
|
rcCbSwitchFabricDropPrec2AcceptedPackets OBJECT-TYPE
|
|
SYNTAX Counter64
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Accepted number of packets from drop precedence 2"
|
|
::= { rcCbSwitchFabricStats 7 }
|
|
|
|
rcCbSwitchFabricDropPrec2AcceptedBytes OBJECT-TYPE
|
|
SYNTAX Counter64
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Accepted number of bytes from drop precedence 2"
|
|
::= { rcCbSwitchFabricStats 8 }
|
|
|
|
rcCbSwitchFabricDropPrec2CongestionMarkedPackets OBJECT-TYPE
|
|
SYNTAX Counter64
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Congestion marked number of packets from drop precedence 2."
|
|
::= { rcCbSwitchFabricStats 9 }
|
|
|
|
rcCbSwitchFabricDropPrec2CongestionMarkedBytes OBJECT-TYPE
|
|
SYNTAX Counter64
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Congestion marked number of bytes from drop precedence 2."
|
|
::= { rcCbSwitchFabricStats 10 }
|
|
|
|
rcCbSwitchFabricDropPrec2DiscardDroppedPackets OBJECT-TYPE
|
|
SYNTAX Counter64
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "WRED dropped number of packets from drop precedence 2."
|
|
::= { rcCbSwitchFabricStats 11 }
|
|
|
|
rcCbSwitchFabricDropPrec2DiscardDroppedBytes OBJECT-TYPE
|
|
SYNTAX Counter64
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "WRED dropped number of bytes from drop precedence 2."
|
|
::= { rcCbSwitchFabricStats 12 }
|
|
|
|
rcCbSwitchFabricDropPrec3AcceptedPackets OBJECT-TYPE
|
|
SYNTAX Counter64
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Accepted number of packets from drop precedence 3"
|
|
::= { rcCbSwitchFabricStats 13 }
|
|
|
|
rcCbSwitchFabricDropPrec3AcceptedBytes OBJECT-TYPE
|
|
SYNTAX Counter64
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Accepted number of bytes from drop precedence 3"
|
|
::= { rcCbSwitchFabricStats 14 }
|
|
|
|
rcCbSwitchFabricDropPrec3CongestionMarkedPackets OBJECT-TYPE
|
|
SYNTAX Counter64
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Congestion marked number of packets from drop precedence 3."
|
|
::= { rcCbSwitchFabricStats 15 }
|
|
|
|
rcCbSwitchFabricDropPrec3CongestionMarkedBytes OBJECT-TYPE
|
|
SYNTAX Counter64
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Congestion marked number of bytes from drop precedence 3."
|
|
::= { rcCbSwitchFabricStats 16 }
|
|
|
|
rcCbSwitchFabricDropPrec3DiscardDroppedPackets OBJECT-TYPE
|
|
SYNTAX Counter64
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "WRED dropped number of packets from drop precedence 3."
|
|
::= { rcCbSwitchFabricStats 17 }
|
|
|
|
rcCbSwitchFabricDropPrec3DiscardDroppedBytes OBJECT-TYPE
|
|
SYNTAX Counter64
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "WRED dropped number of bytes from drop precedence 3."
|
|
::= { rcCbSwitchFabricStats 18 }
|
|
|
|
rcCbSwitchFabricDropPrec4AcceptedPackets OBJECT-TYPE
|
|
SYNTAX Counter64
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Accepted number of packets from drop precedence 4"
|
|
::= { rcCbSwitchFabricStats 19 }
|
|
|
|
rcCbSwitchFabricDropPrec4AcceptedBytes OBJECT-TYPE
|
|
SYNTAX Counter64
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Accepted number of bytes from drop precedence 4"
|
|
::= { rcCbSwitchFabricStats 20 }
|
|
|
|
rcCbSwitchFabricNonWredDroppedPackets OBJECT-TYPE
|
|
SYNTAX Counter64
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Dropped packets due to non Random Early Detection"
|
|
::= { rcCbSwitchFabricStats 21 }
|
|
|
|
rcCbSwitchFabricNonWredDroppedBytes OBJECT-TYPE
|
|
SYNTAX Counter64
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Dropped packets bytes due to non Random Early Detection"
|
|
::= { rcCbSwitchFabricStats 22 }
|
|
|
|
rcCbSwitchFabricDequeuedPackets OBJECT-TYPE
|
|
SYNTAX Counter64
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Packets dequeued once inside the switch fabric"
|
|
::= { rcCbSwitchFabricStats 23 }
|
|
|
|
rcCbSwitchFabricDequeuedBytes OBJECT-TYPE
|
|
SYNTAX Counter64
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Packets bytes dequeued once inside the switch fabric"
|
|
::= { rcCbSwitchFabricStats 24 }
|
|
|
|
rcCbSwitchFabricDropPrec1DroppedPackets OBJECT-TYPE
|
|
SYNTAX Counter64
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "non-WRED dropped number of packets from drop precedence 1."
|
|
::= { rcCbSwitchFabricStats 25 }
|
|
|
|
rcCbSwitchFabricDropPrec1DroppedBytes OBJECT-TYPE
|
|
SYNTAX Counter64
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "non-WRED dropped number of bytes from drop precedence 1."
|
|
::= { rcCbSwitchFabricStats 26 }
|
|
|
|
rcCbSwitchFabricDropPrec2DroppedPackets OBJECT-TYPE
|
|
SYNTAX Counter64
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "non-WRED dropped number of packets from drop precedence 2."
|
|
::= { rcCbSwitchFabricStats 27 }
|
|
|
|
rcCbSwitchFabricDropPrec2DroppedBytes OBJECT-TYPE
|
|
SYNTAX Counter64
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "non-WRED dropped number of bytes from drop precedence 2."
|
|
::= { rcCbSwitchFabricStats 28 }
|
|
|
|
rcCbSwitchFabricDropPrec3DroppedPackets OBJECT-TYPE
|
|
SYNTAX Counter64
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "non-WRED dropped number of packets from drop precedence 3."
|
|
::= { rcCbSwitchFabricStats 29 }
|
|
|
|
rcCbSwitchFabricDropPrec3DroppedBytes OBJECT-TYPE
|
|
SYNTAX Counter64
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "non-WRED dropped number of bytes from drop precedence 3."
|
|
::= { rcCbSwitchFabricStats 30 }
|
|
|
|
rcCbSwitchFabricDropPrec4CongestionMarkedPackets OBJECT-TYPE
|
|
SYNTAX Counter64
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Congestion marked number of packets from drop precedence 4."
|
|
::= { rcCbSwitchFabricStats 31 }
|
|
|
|
rcCbSwitchFabricDropPrec4CongestionMarkedBytes OBJECT-TYPE
|
|
SYNTAX Counter64
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Congestion marked number of bytes from drop precedence 4."
|
|
::= { rcCbSwitchFabricStats 32 }
|
|
|
|
rcCbSwitchFabricDropPrec4DiscardDroppedPackets OBJECT-TYPE
|
|
SYNTAX Counter64
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "WRED dropped number of packets from drop precedence 4."
|
|
::= { rcCbSwitchFabricStats 33 }
|
|
|
|
rcCbSwitchFabricDropPrec4DiscardDroppedBytes OBJECT-TYPE
|
|
SYNTAX Counter64
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "WRED dropped number of bytes from drop precedence 4."
|
|
::= { rcCbSwitchFabricStats 34 }
|
|
|
|
rcCbSwitchFabricDropPrec4DroppedPackets OBJECT-TYPE
|
|
SYNTAX Counter64
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "non-WRED dropped number of packets from drop precedence 4."
|
|
::= { rcCbSwitchFabricStats 35 }
|
|
|
|
rcCbSwitchFabricDropPrec4DroppedBytes OBJECT-TYPE
|
|
SYNTAX Counter64
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "non-WRED dropped number of bytes from drop precedence 4."
|
|
::= { rcCbSwitchFabricStats 36 }
|
|
|
|
rcCbSwitchFabricOverSubscribeTotalDroppedPkts OBJECT-TYPE
|
|
SYNTAX Counter64
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Dropped number of packets due to free list underflow."
|
|
::= { rcCbSwitchFabricStats 37 }
|
|
|
|
rcCbSwitchFabricOverSubscribeTotalDroppedBytes OBJECT-TYPE
|
|
SYNTAX Counter64
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Dropped number of bytes due to free list underflow."
|
|
::= { rcCbSwitchFabricStats 38 }
|
|
|
|
rcCbSwitchFabricOverSubscribeGuaranteeDroppedPkts OBJECT-TYPE
|
|
SYNTAX Counter64
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Dropped number of packets Gbl buf thres guarantee."
|
|
::= { rcCbSwitchFabricStats 39 }
|
|
|
|
rcCbSwitchFabricOverSubscribeGuaranteeDroppedBytes OBJECT-TYPE
|
|
SYNTAX Counter64
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Dropped number of bytes Gbl buf thres guarantee."
|
|
::= { rcCbSwitchFabricStats 40 }
|
|
|
|
rcCbSwitchFabricOutPkts OBJECT-TYPE
|
|
SYNTAX Counter64
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Number of packets out from egress interface."
|
|
::= { rcCbSwitchFabricStats 41 }
|
|
|
|
rcCbSwitchFabricOutBytes OBJECT-TYPE
|
|
SYNTAX Counter64
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Number of bytes out from egress interface."
|
|
::= { rcCbSwitchFabricStats 42 }
|
|
|
|
rcCbSwitchFabricStatsCapture OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Control to turn stats collection on or off"
|
|
::= { rcCbSwitchFabricScalars 2 }
|
|
|
|
rcCbSwitchFabricStatsPortId OBJECT-TYPE
|
|
SYNTAX InterfaceIndex
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "The port on which stats is to be collected on.
|
|
Must select a data port."
|
|
::= { rcCbSwitchFabricScalars 3 }
|
|
|
|
rcCbSwitchFabricStatsCosId OBJECT-TYPE
|
|
SYNTAX Integer32 (0..7)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "The CoS or VOQ to collect Stats on"
|
|
::= { rcCbSwitchFabricScalars 4 }
|
|
|
|
rcCbBmeActiveBme OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
activeArbitorId0(1), -- slot 24
|
|
activeArbitorId1(2) -- slot 21
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The location of the active BME in the system.
|
|
BME stands for Bandwidth Manager Engine."
|
|
::= { rcCbSwitchFabricScalars 5 }
|
|
|
|
rcCbBmeRedundancyMode OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
manual(1),
|
|
onePlusOneControlAndData(2),
|
|
onePlusOneControlOnly(3)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Redundancy mode for BMEs."
|
|
::= { rcCbSwitchFabricScalars 6 }
|
|
|
|
rcCbProfileType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
balanced(1),
|
|
unicastOptimized(2),
|
|
multicastOptimized(3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Switch fabric profile type."
|
|
DEFVAL { balanced }
|
|
::= { rcCbSwitchFabricScalars 7}
|
|
|
|
rcCbSwitchFabricDeviceRead OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "If turned on statistics for switch fabric counters
|
|
are collected directly from devices. Otherwise,
|
|
a cached copy is returned."
|
|
DEFVAL { true }
|
|
::= { rcCbSwitchFabricScalars 8}
|
|
|
|
rcCbQueuingEngine2kTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF RcCBQueuingEngine2kEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "Table containing the 2k based queuing engine
|
|
entries for the system."
|
|
::= { rcCbSwitchFabric 2 }
|
|
|
|
rcCbQueuingEngine2kEntry OBJECT-TYPE
|
|
SYNTAX RcCBQueuingEngine2kEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "Entry for the QE Table"
|
|
INDEX { rcCbQueuingEngine2kId }
|
|
::= { rcCbQueuingEngine2kTable 1 }
|
|
|
|
RcCBQueuingEngine2kEntry ::= SEQUENCE {
|
|
rcCbQueuingEngine2kId Integer32,
|
|
rcCbQueuingEngine2kStatus DeviceStatus
|
|
}
|
|
|
|
rcCbQueuingEngine2kId OBJECT-TYPE
|
|
SYNTAX Integer32 (1..32)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "Index for an entry in the QE Table. Here is the layout
|
|
of the IDs in relation to the system:
|
|
|
|
Location ID(s)
|
|
---------------------
|
|
IO on slot 3: 1..3
|
|
IO on slot 4: 4..6
|
|
CP on slot 1: 7
|
|
CP on slot 2: 8
|
|
IO on slot 5: 9..11
|
|
IO on slot 6: 12..14
|
|
...
|
|
IO on slot 12: 30..32
|
|
"
|
|
::= { rcCbQueuingEngine2kEntry 1 }
|
|
|
|
rcCbQueuingEngine2kStatus OBJECT-TYPE
|
|
SYNTAX DeviceStatus
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Status of a given QE interface."
|
|
::= { rcCbQueuingEngine2kEntry 2 }
|
|
|
|
rcCbSwitchingEngine4kTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF RcCBSwitchingEngine4kEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "Table containing the 4k based switching
|
|
engine entries for the system."
|
|
::= { rcCbSwitchFabric 3 }
|
|
|
|
rcCbSwitchingEngine4kEntry OBJECT-TYPE
|
|
SYNTAX RcCBSwitchingEngine4kEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "Entry for the SE Table."
|
|
INDEX { rcCbSwitchingEngine4kId }
|
|
::= { rcCbSwitchingEngine4kTable 1 }
|
|
|
|
RcCBSwitchingEngine4kEntry ::= SEQUENCE {
|
|
rcCbSwitchingEngine4kId Integer32,
|
|
rcCbSwitchingEngine4kStatus DeviceStatus
|
|
}
|
|
|
|
rcCbSwitchingEngine4kId OBJECT-TYPE
|
|
SYNTAX Integer32 (1..18)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "Index for the SE Table. Here is the layout
|
|
of the IDs in relation to the system:
|
|
|
|
Location ID(s)
|
|
---------------------
|
|
SF on slot 13: 1..3
|
|
SF on slot 14: 4..6
|
|
...
|
|
SF on slot 18: 16..18
|
|
"
|
|
::= { rcCbSwitchingEngine4kEntry 1 }
|
|
|
|
rcCbSwitchingEngine4kStatus OBJECT-TYPE
|
|
SYNTAX DeviceStatus
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Status of a given SE Device."
|
|
::= { rcCbSwitchingEngine4kEntry 2 }
|
|
|
|
rcCbSwitchingEngine9600Table OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF RcCBSwitchingEngine9600Entry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "Table containing the 9600 based switching
|
|
engine entries for the system."
|
|
::= { rcCbSwitchFabric 4 }
|
|
|
|
rcCbSwitchingEngine9600Entry OBJECT-TYPE
|
|
SYNTAX RcCBSwitchingEngine9600Entry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "Entry for the SE 9600 Table."
|
|
INDEX { rcCbSwitchingEngine9600Id }
|
|
::= { rcCbSwitchingEngine9600Table 1 }
|
|
|
|
RcCBSwitchingEngine9600Entry ::= SEQUENCE {
|
|
rcCbSwitchingEngine9600Id Integer32,
|
|
rcCbSwitchingEngine9600Status DeviceStatus,
|
|
rcCbSwitchingEngine9600Mode SfDeviceMode
|
|
}
|
|
|
|
rcCbSwitchingEngine9600Id OBJECT-TYPE
|
|
SYNTAX Integer32 (1..12)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "Index for the SE Table. Here is the layout
|
|
of the IDs in relation to the system:
|
|
|
|
Location ID(s)
|
|
---------------------
|
|
SF on slot 21: 1..2
|
|
SF on slot 22: 3..4
|
|
...
|
|
SF on slot 26: 11..12
|
|
"
|
|
::= { rcCbSwitchingEngine9600Entry 1 }
|
|
|
|
rcCbSwitchingEngine9600Status OBJECT-TYPE
|
|
SYNTAX DeviceStatus
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Status of a given Fast SE Device."
|
|
::= { rcCbSwitchingEngine9600Entry 2 }
|
|
|
|
rcCbSwitchingEngine9600Mode OBJECT-TYPE
|
|
SYNTAX SfDeviceMode
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Mode of given Fast SE Device either BME or SE."
|
|
::= { rcCbSwitchingEngine9600Entry 3 }
|
|
|
|
rcCbQe2kSerdesLinkTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF RcCbQe2kSerdesLinkEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "Table containing the Serdes Link Information
|
|
for the system."
|
|
::= { rcCbSwitchFabric 5 }
|
|
|
|
rcCbQe2kSerdesLinkEntry OBJECT-TYPE
|
|
SYNTAX RcCbQe2kSerdesLinkEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "Entry for a QE based Serdes Link Interface.
|
|
The combination of the QE ID and Serdes Link ID
|
|
uniquely identifies a link."
|
|
INDEX { rcCbQe2kSerdesLinkId}
|
|
::= { rcCbQe2kSerdesLinkTable 1 }
|
|
|
|
RcCbQe2kSerdesLinkEntry ::= SEQUENCE {
|
|
rcCbQe2kSerdesLinkId Integer32,
|
|
rcCbQe2kSerdesLinkType INTEGER,
|
|
rcCbQe2kSerdesLinkStatus DeviceStatus,
|
|
rcCbQe2kSerdesLinkConnectedToDevice Integer32,
|
|
rcCbQe2kSerdesLinkConnectedToSlot Integer32
|
|
}
|
|
|
|
rcCbQe2kSerdesLinkId OBJECT-TYPE
|
|
SYNTAX Integer32 (1..768)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "This ID maps to a particular serdes port number
|
|
for the identified device. Gen-2 IO modules in
|
|
VSP9000 has 24 serdes links per QE, where as Gen-1
|
|
modules will have 20 serdes links per QE. The last 4
|
|
SerdesLinkId will be unused for Gen-1 IO modules.
|
|
Here's the mapping for VSP9000:
|
|
slot 3 :
|
|
rcCbQe2kSerdesLinkId 1 = port 0; Slot 3; QE Device 1
|
|
...
|
|
rcCbQe2kSerdesLinkId 20 = port 19; Slot 3; QE Device 1; last port for Gen-1
|
|
rcCbQe2kSerdesLinkId 24 = port 23; Slot 3; QE Device 1; last port for Gen-2
|
|
rcCbQe2kSerdesLinkId 25 = port 0; Slot 3; QE Device 2
|
|
rcCbQe2kSerdesLinkId 47 = port 23; Slot 3; QE Device 2
|
|
rcCbQe2kSerdesLinkId 48 = port 0; Slot 3; QE Device 2
|
|
rcCbQe2kSerdesLinkId 72 = port 23; Slot 3; QE Device 3
|
|
slot-4 :
|
|
rcCbQe2kSerdesLinkId 73 = port 0; Slot 4; QE Device 1
|
|
...
|
|
rcCbQe2kSerdesLinkId 92 = port 19; Slot 4; QE Device 1; last port for Gen-1
|
|
rcCbQe2kSerdesLinkId 96 = port 23; Slot 4; QE Device 1; last port for Gen-2
|
|
rcCbQe2kSerdesLinkId 97 = port 0; Slot 4; QE Device 2
|
|
rcCbQe2kSerdesLinkId 120 = port 23; Slot 4; QE Device 2
|
|
rcCbQe2kSerdesLinkId 121 = port 0; Slot 4; QE Device 2
|
|
rcCbQe2kSerdesLinkId 144 = port 23; Slot 4; QE Device 3
|
|
... with slots 5 in order with serdes linkIds from 145 to 216
|
|
... with slots 6-12 in order with serdes linkIds from 265 to 768 ...
|
|
rcCbQe2kSerdesLinkId 768 = port 23; Slot 12; QE Device 3
|
|
Note link 15 & 17 are used when QE2k is connected to SF96."
|
|
::= { rcCbQe2kSerdesLinkEntry 1 }
|
|
|
|
rcCbQe2kSerdesLinkType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
sci(1),
|
|
sfi(2)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Link type of the serdes interface"
|
|
::= { rcCbQe2kSerdesLinkEntry 2 }
|
|
|
|
rcCbQe2kSerdesLinkStatus OBJECT-TYPE
|
|
SYNTAX DeviceStatus
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Interface Status"
|
|
::= { rcCbQe2kSerdesLinkEntry 3 }
|
|
|
|
rcCbQe2kSerdesLinkConnectedToDevice OBJECT-TYPE
|
|
SYNTAX Integer32 (1..20)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The SE/BME ID to which the QE2k ID is attached
|
|
to. Note that IDs 16 & 18 are unused."
|
|
::= { rcCbQe2kSerdesLinkEntry 4 }
|
|
|
|
rcCbQe2kSerdesLinkConnectedToSlot OBJECT-TYPE
|
|
SYNTAX Integer32 (21..26)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The slot number of the switch fabric card to which the QE2k ID is attached to."
|
|
::= { rcCbQe2kSerdesLinkEntry 5 }
|
|
|
|
rcCbSESerdesLinkTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF RcCBSESerdesLinkEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "Table containing the Serdes Link Information
|
|
for the system."
|
|
::= { rcCbSwitchFabric 6 }
|
|
|
|
rcCbSESerdesLinkEntry OBJECT-TYPE
|
|
SYNTAX RcCBSESerdesLinkEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "Entry for an SE based Serdes Link Interface.
|
|
The combination of the QE ID and Serdes Link ID
|
|
uniquely identifies a link."
|
|
INDEX { rcCbSESerdesLinkId}
|
|
::= { rcCbSESerdesLinkTable 1 }
|
|
|
|
RcCBSESerdesLinkEntry ::= SEQUENCE {
|
|
rcCbSESerdesLinkId Integer32,
|
|
rcCbSESerdesLinkType INTEGER,
|
|
rcCbSESerdesLinkStatus DeviceStatus,
|
|
rcCbSESerdesLinkConnectedToDevice Integer32,
|
|
rcCbSESerdesLinkConnectedToSlot Integer32
|
|
}
|
|
|
|
rcCbSESerdesLinkId OBJECT-TYPE
|
|
SYNTAX Integer32 (1..640)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "This ID maps to a particular serdes port number
|
|
for the identified device. Here's the mapping:
|
|
|
|
SESerdesLinkId 1 = port 0; Slot 21; Device 1
|
|
SESerdesLinkId 33 = port 0; Slot 21; Device 2
|
|
SESerdesLinkId 65 = port 0; Slot 21; Device 3
|
|
SESerdesLinkId 97 = port 0; Slot 22; Device 1
|
|
...
|
|
SESerdesLinkId 640 = port 31; Slot 26; Device 3"
|
|
::= { rcCbSESerdesLinkEntry 1 }
|
|
|
|
rcCbSESerdesLinkType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
sci(1),
|
|
sfi(2)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Link Type of the Serdes interface. Switch control
|
|
interface is sci. Switch forwarding interface is sfi."
|
|
::= { rcCbSESerdesLinkEntry 2 }
|
|
|
|
rcCbSESerdesLinkStatus OBJECT-TYPE
|
|
SYNTAX DeviceStatus
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Interface Status"
|
|
::= { rcCbSESerdesLinkEntry 3 }
|
|
|
|
rcCbSESerdesLinkConnectedToDevice OBJECT-TYPE
|
|
SYNTAX Integer32 (1..32)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The QE2k ID to which the SE/BME ID is attached to."
|
|
::= { rcCbSESerdesLinkEntry 4 }
|
|
|
|
rcCbSESerdesLinkConnectedToSlot OBJECT-TYPE
|
|
SYNTAX Integer32 (1..32)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The slot number of the switch fabric card to which the QE2k ID is attached to."
|
|
::= { rcCbSESerdesLinkEntry 5 }
|
|
|
|
rcCbSE9600SerdesLinkTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF RcCBSE9600SerdesLinkEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "Table containing the Fast Serdes Link Information
|
|
for the system."
|
|
::= { rcCbSwitchFabric 7 }
|
|
|
|
rcCbSE9600SerdesLinkEntry OBJECT-TYPE
|
|
SYNTAX RcCBSE9600SerdesLinkEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "Entry for an SE based Serdes Link Interface.
|
|
The combination of the QE ID and Serdes Link ID
|
|
uniquely identifies a link."
|
|
INDEX { rcCbSE9600SerdesLinkId}
|
|
::= { rcCbSE9600SerdesLinkTable 1 }
|
|
|
|
RcCBSE9600SerdesLinkEntry ::= SEQUENCE {
|
|
rcCbSE9600SerdesLinkId Integer32,
|
|
rcCbSE9600SerdesLinkType INTEGER,
|
|
rcCbSE9600SerdesLinkStatus DeviceStatus,
|
|
rcCbSE9600SerdesLinkConnectedToDevice Integer32,
|
|
rcCbSE9600SerdesLinkConnectedToSlot Integer32
|
|
}
|
|
|
|
rcCbSE9600SerdesLinkId OBJECT-TYPE
|
|
SYNTAX Integer32 (1..1152)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "This ID maps to a particular serdes port number
|
|
for the identified device. Here's the mapping:
|
|
|
|
SESerdesLinkId 1 = port 0; Slot 21; Device 1
|
|
SESerdesLinkId 97 = port 0; Slot 21; Device 2
|
|
SESerdesLinkId 193 = port 0; Slot 22; Device 1
|
|
SESerdesLinkId 289 = port 0; Slot 22; Device 2
|
|
...
|
|
SESerdesLinkId 1152 = port 96; Slot 26; Device 2"
|
|
::= { rcCbSE9600SerdesLinkEntry 1 }
|
|
|
|
rcCbSE9600SerdesLinkType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
sci(1),
|
|
sfi(2)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Link Type of the Serdes interface. Switch control
|
|
interface is sci. Switch forwarding interface is sfi."
|
|
::= { rcCbSE9600SerdesLinkEntry 2 }
|
|
|
|
rcCbSE9600SerdesLinkStatus OBJECT-TYPE
|
|
SYNTAX DeviceStatus
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Interface Status"
|
|
::= { rcCbSE9600SerdesLinkEntry 3 }
|
|
|
|
rcCbSE9600SerdesLinkConnectedToDevice OBJECT-TYPE
|
|
SYNTAX Integer32 (1..32)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The QE2k ID to which the SE/BME ID is attached to."
|
|
::= { rcCbSE9600SerdesLinkEntry 4 }
|
|
|
|
rcCbSE9600SerdesLinkConnectedToSlot OBJECT-TYPE
|
|
SYNTAX Integer32 (1..12)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The slot number of the switch fabric card to which the QE2k ID is attached to."
|
|
::= { rcCbSE9600SerdesLinkEntry 5 }
|
|
|
|
rcCbSPITable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF RcCBSPIEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "Table containing the system peripheral interface info."
|
|
::= { rcCbSwitchFabric 8 }
|
|
|
|
rcCbSPIEntry OBJECT-TYPE
|
|
SYNTAX RcCBSPIEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "SPI table entry"
|
|
INDEX { rcCbSPIId }
|
|
::= { rcCbSPITable 1 }
|
|
|
|
RcCBSPIEntry ::= SEQUENCE {
|
|
rcCbSPIId Integer32,
|
|
rcCbSPIStatus DeviceStatus
|
|
}
|
|
|
|
rcCbSPIId OBJECT-TYPE
|
|
SYNTAX Integer32 (1..72)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "The Index for the SPI Table. Here is the layout
|
|
of the IDs in relation to the system:
|
|
|
|
Location ID(s)
|
|
---------------------
|
|
Slot 1: 1..6
|
|
Slot 2: 7..12
|
|
...
|
|
Slot 12: 57..72
|
|
|
|
Current implementation uses the first 6 IDs for each slot. "
|
|
::= { rcCbSPIEntry 1 }
|
|
|
|
rcCbSPIStatus OBJECT-TYPE
|
|
SYNTAX DeviceStatus
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "SPI Status"
|
|
::= { rcCbSPIEntry 2 }
|
|
|
|
-- Notification
|
|
|
|
rcLoginUserName OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (1..20))
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION "Used to inidcation the login user name for notification"
|
|
::= { rcCbNotifications 1 }
|
|
|
|
rcLoginHostIpAddress OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION "Used to inidcation the login host ip address for
|
|
notification"
|
|
::= {rcCbNotifications 2 }
|
|
|
|
rcSlotType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
slot1(1),
|
|
slot2(2),
|
|
slot3(3),
|
|
slot4(4),
|
|
slot5(5),
|
|
slot6(6),
|
|
slot7(7),
|
|
slot8(8),
|
|
slot9(9),
|
|
slot10(10),
|
|
slot11(11),
|
|
slot12(12),
|
|
ps1(13),
|
|
ps2(14),
|
|
ps3(15),
|
|
ps4(16),
|
|
ps5(17),
|
|
ps6(18),
|
|
mid1(19),
|
|
mid2(20),
|
|
sf1(21),
|
|
sf2(22),
|
|
sf3(23),
|
|
sf4(24),
|
|
sf5(25),
|
|
sf6(26),
|
|
aux1(27),
|
|
aux2(28),
|
|
iofan1(29),
|
|
iofan2(30),
|
|
sffan1(31),
|
|
sffan2(32)
|
|
}
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION "Used to inidcate the slot type"
|
|
::= { rcCbNotifications 3 }
|
|
|
|
rcFanZoneType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
front(1),
|
|
rear(2)
|
|
}
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION "Type of the fan zone."
|
|
::= { rcCbNotifications 4 }
|
|
|
|
rcFanTrayId OBJECT-TYPE
|
|
SYNTAX INTEGER (1..6)
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION "Fan tray number in the fan zone"
|
|
::= { rcCbNotifications 5 }
|
|
|
|
rcFanUnitId OBJECT-TYPE
|
|
SYNTAX INTEGER (1..8)
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION "Fan unit number in the fan tray"
|
|
::= { rcCbNotifications 6 }
|
|
|
|
rcCardTemp OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION "Used to inidcate the card temperature"
|
|
::= { rcCbNotifications 7 }
|
|
|
|
rcCpuUtilization OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION "Used to inidcate the CPU utilization"
|
|
::= { rcCbNotifications 8 }
|
|
|
|
rcLoginHostAddressType OBJECT-TYPE
|
|
SYNTAX InetAddressType
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION "Used to inidcation the login host address type for
|
|
notification"
|
|
::= {rcCbNotifications 9 }
|
|
|
|
rcLoginHostInetAddress OBJECT-TYPE
|
|
SYNTAX InetAddress
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION "Used to inidcation the login host inet address for
|
|
notification"
|
|
::= {rcCbNotifications 10 }
|
|
|
|
rcSlotPowerStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
notAvailable(1),
|
|
available(2)
|
|
}
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION "Whethere power is available to boot up
|
|
the card in the slot."
|
|
::= {rcCbNotifications 11 }
|
|
|
|
rc2kCardShutDownReason OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
highSpeedFanNeeded(1)
|
|
}
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION "The reason can not boot up the card in the slot."
|
|
::= { rcCbNotifications 12 }
|
|
|
|
rc2kCardZoneTemperature OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION "Used to indicate the card zone temperature"
|
|
::= { rcCbNotifications 13 }
|
|
|
|
rc2kCardTemperatureZoneInfo OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
inletOutletZone(1),
|
|
fpgaZone(2),
|
|
faZone(3),
|
|
cpu(4),
|
|
cpu1(5),
|
|
cpuCore(6),
|
|
mac(7),
|
|
mac1(8),
|
|
mac2(9),
|
|
phy(10),
|
|
phy1(11),
|
|
phy2(12),
|
|
phy3(13),
|
|
phy4(14),
|
|
phy5(15),
|
|
phy6(16),
|
|
pressFitConnector(17),
|
|
mgmtBrd(18),
|
|
mb(19),
|
|
mainBoard1(20),
|
|
mainBoard2(21),
|
|
vim(22),
|
|
vimPhy(23),
|
|
unknown(24)
|
|
}
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION "rc2kCardTemperatureZoneInfo indicates the zone for which the
|
|
card temperature trap (rcn2kCardZoneOverheat, rcn2kCardZoneNormalTemp
|
|
and rcn2kCardOverheatShutDown) is raised."
|
|
::= { rcCbNotifications 14 }
|
|
|
|
END
|