Observium_CE/mibs/nokia/TROPIC-AMPLIFIER-MIB

2879 lines
116 KiB
Plaintext

TROPIC-AMPLIFIER-MIB DEFINITIONS ::= BEGIN
-- (c) Copyright 2021 Nokia Networks. All rights reserved.
-- This software is the confidential and proprietary property of
-- Nokia and may only be used in accordance with the terms of the
-- license agreement provided with this software.
IMPORTS
SnmpAdminString FROM SNMP-FRAMEWORK-MIB
OBJECT-TYPE, MODULE-IDENTITY,
Unsigned32, Integer32 FROM SNMPv2-SMI
MODULE-COMPLIANCE, OBJECT-GROUP FROM SNMPv2-CONF
TruthValue FROM SNMPv2-TC
ifIndex, InterfaceIndexOrZero FROM IF-MIB
tnShelfIndex FROM TROPIC-SHELF-MIB
tnSlotIndex FROM TROPIC-SLOT-MIB
TnCommand,
NokiaAmpPortTargetPowerWidth FROM TROPIC-TC
tnCardModules, tnAmplifierMIB FROM TROPIC-GLOBAL-REG;
tnAmplifierMibModule MODULE-IDENTITY
LAST-UPDATED "202107231200Z"
ORGANIZATION "Nokia"
CONTACT-INFO "Nokia
Attn: Jeff Donnelly
600 Mountain Avenue
New Providence, NJ 07974
Phone: +1 732 221 6408
Email: jeff.donnelly@nokia.com"
DESCRIPTION "Amplifier MIB types."
REVISION "202107231200Z"
DESCRIPTION "Added the following to tnAmplifierPortInfoTable:
tnAmplifierPortAprEDFApulsePower."
REVISION "202106041200Z"
DESCRIPTION "Added the following to tnAmplifierPortConfigTable:
tnAmplifierPortAsellLinkL."
REVISION "202012181200Z"
DESCRIPTION "Added the following to tnAmplifierPortConfigTable:
tnAmplifierPortTargetPowerWidth
tnAmplifierPortTargetPowerWidthL."
REVISION "202011061200Z"
DESCRIPTION "Added the following to tnAmplifierPortConfigTable:
tnAmplifierPortAsellLink."
REVISION "202010301200Z"
DESCRIPTION "1) Added the following to tnAmplifierPortConfigTable:
tnAmplifierPortSpanLossTh.
2) Added the following to tnAmplifierPortInfoTable:
tnAmplifierPortSpanLoss."
REVISION "202003061200Z"
DESCRIPTION "Added the following to tnAmplifierPortConfigTable:
tnAmplifierPortAPREDFAPulseAttempt."
REVISION "202002141200Z"
DESCRIPTION "Added the following to tnAmplifierPortOperatingMode:
maxPower(3)."
REVISION "202001311200Z"
DESCRIPTION "Added the following to tnAmplifierPortOperatingModeL:
maxPower(3)."
REVISION "202001171200Z"
DESCRIPTION "Added the following to tnAmplifierPortConfigTable:
tnAmplifierPortLineDcmConnAddress."
REVISION "201810101200Z"
DESCRIPTION "Added the following to tnAmplifierPortConfigTable:
tnAmplifierPortAprEDFApulse."
REVISION "201805181200Z"
DESCRIPTION "Added the following to tnAmplifierPortInfoTable:
tnAmplifierPortPowerOutL."
REVISION "201803301200Z"
DESCRIPTION "1) Added the following to tnAmplifierPortConfigTable:
tnAmplifierPortBoosterTargetPowerIn.
2) Added the following to tnAmplifierPortInfoTable:
tnAmplifierPortInfoOSCRxPowerIn
tnAmplifierPortInfoOSCSfpTxPowerOut
tnAmplifierPortInfoOSCSfpRxPowerIn
tnAmplifierPortBoosterTargetPowerOut.
3) Added the following to tnAmplifierCardInfoTable:
tnAmplifierCardOAM3PumpTemperatures
tnAmplifierCardOAM3PumpBiases."
REVISION "201802231200Z"
DESCRIPTION "Updated the contact info."
REVISION "201802091200Z"
DESCRIPTION "Added the following to tnAmplifierPortConfigTable:
tnAmplifierPortLosModeL."
REVISION "201709291200Z"
DESCRIPTION "1) Added the following to tnAmplifierPortConfigTable:
tnAmplifierPortBandMode.
2) Added the following to tnAmplifierPortInfoTable:
tnAmplifierPortPowerInL."
REVISION "201709221200Z"
DESCRIPTION "Removed the range of the following in tnAmplifierPortInfoTable:
tnAmplifierActOutAtten
tnAmplifierActOutAttenL."
REVISION "201707071200Z"
DESCRIPTION "Fixed MIB compile issues."
REVISION "201706231200Z"
DESCRIPTION "Added the following to tnAmplifierCardInfoTable:
tnAmplifierCardOAM1PumpTemperatures
tnAmplifierCardOAM2PumpTemperatures
tnAmplifierCardOAM1PumpBiases
tnAmplifierCardOAM2PumpBiases."
REVISION "201705311200Z"
DESCRIPTION "Added the following to tnAmplifierPortConfigTable:
tnAmplifierPortOperatingModeL
tnAmplifierPortSignalPowerTargetL
tnAmplifierPortUserSelectedExteriorDcmPresentIn
tnAmplifierPortUserSelectedExteriorDcmPresentOut."
REVISION "201702241200Z"
DESCRIPTION "1) Added the following to tnAmplifierPortConfigTable:
tnAmplifierPortGainTiltL
tnAmplifierPortPowerGainBackoffL
tnAmplifierPortPowerSpanRepairMarginL.
2) Added the following to tnAmplifierPortInfoTable:
tnAmplifierPortActualTiltL
tnAmplifierPortSignalPowerOutL
tnAmplifierPortInputToOutputGainL
tnAmplifierPortOSCTxPowerOutL."
REVISION "201611161200Z"
DESCRIPTION "Updated the contact info."
REVISION "201611111200Z"
DESCRIPTION "Added the following to tnAmplifierPortInfoTable:
tnAmplifierCommonEgressOutputPowerL,
tnAmplifierActOutAttenL."
REVISION "201610131200Z"
DESCRIPTION "Added the following to tnAmplifierPortConfigTable:
tnAmplifierPortPowerGainL
tnAmplifierPortPowerGainMinL
tnAmplifierPortPowerGainMaxL
tnAmplifierPortPowerDeltaMaxL
tnAmplifierPortGainRangeL
tnAmplifierPortTargetTiltL
tnAmplifierPortVoaSetL."
REVISION "201605311200Z"
DESCRIPTION "Added the following to tnAmplifierCardInfoTable:
tnAmplifierCardOAMLPump[1-4]Temperature,
tnAmplifierCardOAMLPump[1-4]Bias."
REVISION "201605211200Z"
DESCRIPTION "Added the following to tnAmplifierPortInfoTable:
tnAmplifierCommonEgressOutputPower,
tnAmplifierActOutAtten."
REVISION "201407311200Z"
DESCRIPTION "Changed the syntax of tnAmplifierPortSignalPowerTarget
to Integer32 from Unsigned32."
REVISION "201406121200Z"
DESCRIPTION "1) Added the following to tnAmplifierPortConfigTable:
tnAmplifierPortOperatingMode
tnAmplifierPortSignalPowerTarget.
2) Added the following to tnAmplifierPortInfoTable:
tnAmplifierPortTestingActive."
REVISION "201403181200Z"
DESCRIPTION "Added the following to tnAmplifierHybridCardInfoTable:
tnAmplifierHybridCardOAMPump[3-4]Temperature
tnAmplifierHybridCardOAMPump[3-4]Bias."
REVISION "201403111200Z"
DESCRIPTION "Added the following to tnAmplifierPortConfigTable:
tnAmplifierPortGainRange
tnAmplifierPortAprMode."
REVISION "201402261200Z"
DESCRIPTION "Added ranges and DEFVAL to attributes."
REVISION "201309051200Z"
DESCRIPTION "Added the following to tnAmplifierCardConfigTable:
tnAmplifierCardAsonAddDropPlannedForOps."
REVISION "201305231200Z"
DESCRIPTION "1) Updated ranges and defaults for the following:
tnAmplifierPortPowerSpanRepairMargin.
2) Updated defaults for the following:
tnAmplifierPortGainTilt
tnAmplifierPortPowerOut."
REVISION "201305131200Z"
DESCRIPTION "1) Added the following to tnAmplifierPortInfoTable:
tnAmplifierPortOSCTxPowerIn
tnAmplifierPortOSCTxPowerOut.
2) Marked the following as obsolete:
tnAmplifierObjs
tnAmplifierEvents."
REVISION "201303161200Z"
DESCRIPTION "Added the following to tnAmplifierCardInfoTable:
tnAmplifierCardOAMPump[4-6]Temperature
tnAmplifierCardOAMPump[4-6]Bias."
REVISION "201211261200Z"
DESCRIPTION "Added the following to tnAmplifierPortInfoTable:
tnAmplifierPortWtOcmMonitorPortOut."
REVISION "201209271200Z"
DESCRIPTION "Added the following DEFVAL for tnAmplifierPortAprHoldOffTime:
time0ms."
REVISION "201207161200Z"
DESCRIPTION "Added the following tables:
tnAmplifierHybridPortConfigTable
tnAmplifierHybridPortInfoTable
tnAmplifierHybridCardInfoTable."
REVISION "201106151200Z"
DESCRIPTION "1) Changed range for tnAmplifierMeshCardCommonEgressPower
from (-3000, 1100) to (-1000, 1000), and the default
from 0 to 100.
2) Added DEFVAL for the following attributes:
tnAmplifierMeshPortPowerOut, -9900
tnAmplifierMeshPortSignalPowerOut, -9900."
REVISION "201105231200Z"
DESCRIPTION "Added DEFVAL for the following attributes:
tnAmplifierPortPowerDeltaMax, 0
tnAmplifierPortDCMInPower, -9900
tnAmplifierPortDCMOutPower, -9900."
REVISION "201104281200Z"
DESCRIPTION "Added the following tables:
tnAmplifierMeshPortInfoTable
tnAmplifierMeshCardConfigTable
tnAmplifierMeshCardInfoTable."
REVISION "201103071200Z"
DESCRIPTION "Updated range to (0,9900) and added default of
9900 for tnAmplifierCardOptIntSpanLoss."
REVISION "201011161200Z"
DESCRIPTION "1) Added the following to tnAmplifierCardInfoTable:
tnAmplifierCardOptIntSpanLoss
2) Added the following to a new MIB table,
tnAmplifierCardConfigTable:
tnAmplifierCardOptIntDetection
tnAmplifierCardOptIntBaseline
tnAmplifierCardOptIntLossThreshold
tnAmplifierCardOptIntPollPeriod
tnAmplifierCardOptIntClearAlarm."
REVISION "201010311200Z"
DESCRIPTION "Added ranges for AM2125A and AM2318A to the following:
tnAmplifierPortPowerGain
tnAmplifierPortPowerGainMin
tnAmplifierPortPowerGainMax."
REVISION "201010241200Z"
DESCRIPTION "1) Added the following to tnAmplifierPortConfigTable:
tnAmplifierPortVoaSet.
2) Added the following to tnAmplifierPortInfoTable:
tnAmplifierPortInputToOutputGain
tnAmplifierPortDCMInPower
tnAmplifierPortDCMOutPower
tnAmplifierPortActualTilt."
REVISION "201010181200Z"
DESCRIPTION "Marked the following as obsolete:
tnAmplifierPortAutoReEnableBackoffTime."
REVISION "201010141200Z"
DESCRIPTION "Added the following to tnAmplifierPortConfigTable:
tnAmplifierPortSignalFailThreshold
tnAmplifierPortSignalDegradeThreshold."
REVISION "201009101200Z"
DESCRIPTION "1) Marked the following in tnAmplifierPortAprHoldOffTime
as obsolete:
time50ms(2)
time100ms(3).
2) Added the following to tnAmplifierPortAprHoldOffTime:
time250ms(4)."
REVISION "201008151200Z"
DESCRIPTION "Changed losa(1) to auto(1) for tnAmplifierPortLosMode."
REVISION "201007291200Z"
DESCRIPTION "Added the following to tnAmplifierPortConfigTable:
tnAmplifierPortAprHoldOffTime
tnAmplifierPortLosMode."
REVISION "201007051200Z"
DESCRIPTION "Added the following to tnAmplifierPortConfigTable:
tnAmplifierPortGainTilt."
REVISION "201006161200Z"
DESCRIPTION "Added the following to tnAmplifierPortConfigTable:
tnAmplifierPortSRSTiltACoeffDCM
tnAmplifierPortMaxFlatGainOffset."
REVISION "201006041200Z"
DESCRIPTION "Added ranges for AM2017B and AM2325B to the following:
tnAmplifierPortPowerGain
tnAmplifierPortPowerGainMin
tnAmplifierPortPowerGainMax."
REVISION "201002251200Z"
DESCRIPTION "Updated range for tnAmplifierPortPowerDeltaMax from
(0, 9999) to (0, 500)."
REVISION "201002171200Z"
DESCRIPTION "Added range for ALPFGT to the following:
tnAmplifierPortPowerGain,
tnAmplifierPortPowerGainMin
tnAmplifierPortPowerGainMax."
REVISION "201002091200Z"
DESCRIPTION "Updated range for A2325A to the following:
tnAmplifierPortPowerGain,
tnAmplifierPortPowerGainMin
tnAmplifierPortPowerGainMax."
REVISION "201001241200Z"
DESCRIPTION "1) Added the following MIB table:
tnAmplifierCardInfo.
2) Added the following to tnAmplifierCardInfoTable:
tnAmplifierCardOAMPump[1-3]Temperature
tnAmplifierCardOAMPump[1-3]Bias.
3) Added range for A2325A to the following:
tnAmplifierPortPowerGain
tnAmplifierPortPowerGainMin
tnAmplifierPortPowerGainMax."
REVISION "200912111200Z"
DESCRIPTION "Added tnAmplifierPortAprDisable."
REVISION "200912031200Z"
DESCRIPTION "Added range for ALPFGK to the following:
tnAmplifierPortPowerGain
tnAmplifierPortPowerGainMin
tnAmplifierPortPowerGainMax."
REVISION "200903181200Z"
DESCRIPTION "Added range for AHPLG to the following:
tnAmplifierPortPowerGain,
tnAmplifierPortPowerGainMin
tnAmplifierPortPowerGainMax."
REVISION "200811171200Z"
DESCRIPTION "Changed range of tnAmplifierPortTargetTilt to (-300, 0)."
REVISION "200810161200Z"
DESCRIPTION "Marked the following as deprecated:
tnAmplifierPortAutoReEnableBackoffTime."
REVISION "200805221200Z"
DESCRIPTION "tnAmplifierPortPowerGainBackoff will not be obsoleted."
REVISION "200804111200Z"
DESCRIPTION "1) Updated the amplifier gain attribute ranges to
AHPHG: 1300 to 3300 and ALPHG: 1000 to 3000.
2) Removed:
tnAmplifierPortDeviationIn
tnAmplifierPortDeviationOut."
REVISION "200803281200Z"
DESCRIPTION "Updated the amplifier gain attribute ranges."
REVISION "200802161200Z"
DESCRIPTION "1) Changed the attribute descriptions to include
1830 card types.
2) Added comments to attributes that will be obsoleted.
3) Added the following MIB attributes:
tnAmplifierPortPowerDeltaMax
tnAmplifierPortDeviationIn
tnAmplifierPortDeviationOut
tnAmplifierPortTargetTilt
tnAmplifierPortFunction."
::= { tnCardModules 4 }
tnAmplifierConf OBJECT IDENTIFIER ::= { tnAmplifierMIB 1 }
tnAmplifierGroups OBJECT IDENTIFIER ::= { tnAmplifierConf 1 }
tnAmplifierPortConfigGroups OBJECT IDENTIFIER ::= { tnAmplifierGroups 1 }
tnAmplifierPortInfoGroups OBJECT IDENTIFIER ::= { tnAmplifierGroups 2 }
tnAmplifierCardInfoGroups OBJECT IDENTIFIER ::= { tnAmplifierGroups 3 }
tnAmplifierCardConfigGroups OBJECT IDENTIFIER ::= { tnAmplifierGroups 4 }
tnAmplifierCompliances OBJECT IDENTIFIER ::= { tnAmplifierConf 2 }
tnAmplifierPortConfigCompliances OBJECT IDENTIFIER ::= { tnAmplifierCompliances 1 }
tnAmplifierPortInfoCompliances OBJECT IDENTIFIER ::= { tnAmplifierCompliances 2 }
tnAmplifierCardInfoCompliances OBJECT IDENTIFIER ::= { tnAmplifierCompliances 3 }
tnAmplifierCardConfigCompliances OBJECT IDENTIFIER ::= { tnAmplifierCompliances 4 }
-- obsolete
-- tnAmplifierObjs OBJECT IDENTIFIER ::= { tnAmplifierMIB 2 }
-- tnAmplifierEvents OBJECT IDENTIFIER ::= { tnAmplifierMIB 3 }
tnAmplifierPortConfig OBJECT IDENTIFIER ::= { tnAmplifierMIB 4 }
tnAmplifierPortInfo OBJECT IDENTIFIER ::= { tnAmplifierMIB 5 }
tnAmplifierCardInfo OBJECT IDENTIFIER ::= { tnAmplifierMIB 6 }
tnAmplifierCardConfig OBJECT IDENTIFIER ::= { tnAmplifierMIB 7 }
--------------------------------------------------------------------------------
-- Type Definitions
--------------------------------------------------------------------------------
--------------------------------------------------------------------------------
-- Amplifier Port Config Scalars
--------------------------------------------------------------------------------
tnAmplifierPortConfigAttributeTotal OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Total number of attributes in
tnAmplifierPortConfigTable."
::= { tnAmplifierPortConfig 1 }
--------------------------------------------------------------------------------
-- Amplifier Port Config Table
--------------------------------------------------------------------------------
tnAmplifierPortConfigTable OBJECT-TYPE
SYNTAX SEQUENCE OF TnAmplifierPortConfigEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The provisioned ports on an amplifier card."
::= { tnAmplifierPortConfig 2 }
tnAmplifierPortConfigEntry OBJECT-TYPE
SYNTAX TnAmplifierPortConfigEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "."
INDEX { ifIndex }
::= { tnAmplifierPortConfigTable 1 }
TnAmplifierPortConfigEntry ::= SEQUENCE {
tnAmplifierPortPowerGain Unsigned32,
tnAmplifierPortPowerGainMin Unsigned32,
tnAmplifierPortPowerGainMax Unsigned32,
tnAmplifierPortPowerGainBackoff Unsigned32,
tnAmplifierPortEnable TruthValue,
tnAmplifierPortAutoReEnableMode TruthValue,
-- obsolete
-- tnAmplifierPortAutoReEnableBackoffTime Unsigned32,
tnAmplifierPortPowerSpanRepairMargin Unsigned32,
tnAmplifierPortPowerDeltaMax Unsigned32,
tnAmplifierPortTargetTilt Integer32,
tnAmplifierPortFunction INTEGER,
tnAmplifierPortAprDisable TruthValue,
tnAmplifierPortSRSTiltACoeffDCM Integer32,
tnAmplifierPortMaxFlatGainOffset Integer32,
tnAmplifierPortGainTilt Integer32,
tnAmplifierPortAprHoldOffTime INTEGER,
tnAmplifierPortLosMode INTEGER,
tnAmplifierPortSignalFailThreshold Unsigned32,
tnAmplifierPortSignalDegradeThreshold Unsigned32,
tnAmplifierPortVoaSet Unsigned32,
tnAmplifierPortGainRange INTEGER,
tnAmplifierPortAprMode INTEGER,
tnAmplifierPortOperatingMode INTEGER,
tnAmplifierPortSignalPowerTarget Integer32,
tnAmplifierPortPowerGainL Unsigned32,
tnAmplifierPortPowerGainMinL Unsigned32,
tnAmplifierPortPowerGainMaxL Unsigned32,
tnAmplifierPortPowerDeltaMaxL Unsigned32,
tnAmplifierPortGainRangeL INTEGER,
tnAmplifierPortTargetTiltL Integer32,
tnAmplifierPortVoaSetL Unsigned32,
tnAmplifierPortGainTiltL Integer32,
tnAmplifierPortPowerGainBackoffL Unsigned32,
tnAmplifierPortPowerSpanRepairMarginL Unsigned32,
tnAmplifierPortOperatingModeL INTEGER,
tnAmplifierPortSignalPowerTargetL Integer32,
tnAmplifierPortUserSelectedExteriorDcmPresentIn TruthValue,
tnAmplifierPortUserSelectedExteriorDcmPresentOut TruthValue,
tnAmplifierPortBandMode INTEGER,
tnAmplifierPortLosModeL INTEGER,
tnAmplifierPortBoosterTargetPowerIn Integer32,
tnAmplifierPortAprEDFApulse INTEGER,
tnAmplifierPortLineDcmConnAddress InterfaceIndexOrZero,
tnAmplifierPortAPREDFAPulseAttempt TnCommand,
tnAmplifierPortSpanLossTh Integer32,
tnAmplifierPortAsellLink TruthValue,
tnAmplifierPortTargetPowerWidth NokiaAmpPortTargetPowerWidth,
tnAmplifierPortTargetPowerWidthL NokiaAmpPortTargetPowerWidth,
tnAmplifierPortAsellLinkL TruthValue
}
tnAmplifierPortPowerGain OBJECT-TYPE
SYNTAX Unsigned32
UNITS "mB"
MAX-ACCESS read-create
STATUS current
DESCRIPTION "The following description applies to the signal
port of the amplifier card:
Current configurable ranges and defaults:
A2325A: (1600..3200), 1600
A2P2125 (port 1): ( 200..2000), 1000
A2P2125 (port 4): (1500..3100), 1500
A4PSWG (port 1): ( 700..2900), 700
A4PSWG (port 4): ( 200..2000), 1000
AA2DONW: (1300..2300), 1300
AAR_8A: (1000..2000), 1500
AHPHG: (1300..3300), 1300
AHPLG: ( 600..2400), 600
ALPFGK: (1300..2300), 1800
ALPFGT: (1300..2300), 1800
ALPHG: (1000..3000), 1000
AM2017B: ( 600..2400), 600
AM2032A: (2600..4000), 2600
AM2125A: (1500..3100), 1500
AM2125B: (1500..3100), 1500
AM2318A: ( 700..2400), 700
AM2325B: (1600..3200), 1600
AM2625A: (1600..3000), 1600
ASWG: ( 700..2900), 700
MESH4: ( 700..2400), 700
RA2P: ( 200..2000), 1000."
::= { tnAmplifierPortConfigEntry 1 }
tnAmplifierPortPowerGainMin OBJECT-TYPE
SYNTAX Unsigned32
UNITS "mB"
MAX-ACCESS read-create
STATUS current
DESCRIPTION "The following description applies to the signal
port of the amplifier card:
This value is used by power management.
Current configurable ranges and defaults:
A2325A: (1600..3200), 1600
A2P2125 (port 1): ( 0..2500), 700
A2P2125 (port 4): (1500..3100), 1500
A4PSWG (port 1): ( 0..2500), 700
A4PSWG (port 4): ( 700..2900), 700
AA2DONW: (1300..2300), 1300
AHPHG: (1300..3300), 1300
AHPLG: ( 600..2400), 600
ALPFGK: (1300..2300), 1300
ALPFGT: (1300..2300), 1300
ALPHG: (1000..3000), 1000
AM2017B: ( 600..2400), 600
AM2032A: (2600..4000), 2600
AM2125A: (1500..3100), 1500
AM2125B: (1500..3100), 1500
AM2318A: ( 700..2400), 700
AM2325B: (1600..3200), 1600
AM2625A: (1600..3000), 1600
ASWG: ( 700..2900), 700
MESH4: ( 700..2400), 700
RA2P: ( 0..2500), 700."
::= { tnAmplifierPortConfigEntry 2 }
tnAmplifierPortPowerGainMax OBJECT-TYPE
SYNTAX Unsigned32
UNITS "mB"
MAX-ACCESS read-create
STATUS current
DESCRIPTION "The following description applies to the signal
port of the amplifier card:
This value is used by power management.
Current configurable ranges and defaults:
A2325A: (1600..3200), 3200
A2P2125 (port 1): ( 0..2500), 2500
A2P2125 (port 4): (1500..3100), 3100
A4PSWG (port 1): ( 0..2500), 2500
A4PSWG (port 4): ( 700..2900), 2200
AA2DONW: (1300..2300), 2300
AHPHG: (1300..3300), 3300
AHPLG: ( 600..2400), 2400
ALPFGK: (1300..2300), 2300
ALPFGT: (1300..2300), 2300
ALPHG: (1000..3000), 3000
AM2017B: ( 600..2400), 2400
AM2032A: (2600..4000), 4000
AM2125A: (1500..3100), 3100
AM2125B: (1500..3100), 3100
AM2318A: ( 700..2400), 2400
AM2325B: (1600..3200), 3200
AM2625A: (1600..3000), 3000
ASWG: ( 700..2900), 2200
MESH4: ( 700..2400), 2400
RA2P: ( 0..2500), 2500."
::= { tnAmplifierPortConfigEntry 3 }
tnAmplifierPortPowerGainBackoff OBJECT-TYPE
SYNTAX Unsigned32
UNITS "mB"
MAX-ACCESS read-create
STATUS current
DESCRIPTION "The following description applies to the signal
port of the amplifier card:
The adjustment made to min/max gain by power
management when commissioning.
Current configurable range: 0 to 1000."
DEFVAL { 0 }
::= { tnAmplifierPortConfigEntry 4 }
tnAmplifierPortEnable OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-create
STATUS current
DESCRIPTION "The following description applies to the signal
port of the amplifier card:
This attribute allows a network operator to kick
start the laser. Setting a value of false is
restricted."
DEFVAL { true }
::= { tnAmplifierPortConfigEntry 5 }
tnAmplifierPortAutoReEnableMode OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-create
STATUS current
DESCRIPTION "The following description applies to the
ampOutThruIn port of the amplifier card:
Auto re-enable mode."
DEFVAL { true }
::= { tnAmplifierPortConfigEntry 6 }
-- obsolete
-- tnAmplifierPortAutoReEnableBackoffTime OBJECT-TYPE ::= { tnAmplifierPortConfigEntry 7 }
tnAmplifierPortPowerSpanRepairMargin OBJECT-TYPE
SYNTAX Unsigned32
UNITS "mB"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The following description applies to the signal
port of the amplifier card:
EPT - splice margin.
This is calculated as the absolute value of the
difference between tnAmplifierPortPowerGainMax
and tnAmplifierPortPowerGainBackoff.
Current ranges and defaults:
ASWG: (700..2900), 2200
A4PSWG: (700..2900), 2200."
::= { tnAmplifierPortConfigEntry 8 }
tnAmplifierPortPowerDeltaMax OBJECT-TYPE
SYNTAX Unsigned32
UNITS "mB"
MAX-ACCESS read-create
STATUS current
DESCRIPTION "The following description applies to the signal
port of the amplifier card:
EPT - delta max.
Current configurable range: 0 to 500."
DEFVAL { 0 }
::= { tnAmplifierPortConfigEntry 9 }
tnAmplifierPortTargetTilt OBJECT-TYPE
SYNTAX Integer32
UNITS "mB"
MAX-ACCESS read-create
STATUS current
DESCRIPTION "The following description applies to the signal
port of the amplifier card:
EPT - Tilt.
Configurable ranges and defaults:
A2325A: (-300.. 0), 0
A2P2125: (-300.. 300), 0
A2P2125: (-400.. 400), 0
AHPHG: (-300.. 0), 0
AHPLG: (-300.. 0), 0
ALPHG: (-300.. 0), 0
AM2017B: (-300.. 0), 0
AM2032A: (-300.. 0), 0
AM2125A: (-400.. 400), 0
AM2125B: (-400.. 400), 0
AM2318A: (-400.. 400), 0
AM2325B: (-300.. 0), 0
AM2625A: (-600..-100), -100
MESH4: (-400.. 400), 0
RA2P: (-300.. 300), 0
ASWG: (-400.. 400), 0
A4PSWG: (-400.. 400), 0."
::= { tnAmplifierPortConfigEntry 10 }
tnAmplifierPortFunction OBJECT-TYPE
SYNTAX INTEGER {
ingress(1),
egress(2),
other(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the functional type of the amplifier
card."
::= { tnAmplifierPortConfigEntry 11 }
tnAmplifierPortAprDisable OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-create
STATUS current
DESCRIPTION "The Auto Power Recovery Disable."
DEFVAL { false }
::= { tnAmplifierPortConfigEntry 12 }
tnAmplifierPortSRSTiltACoeffDCM OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-create
STATUS current
DESCRIPTION "Modeling coefficient for the
SRSTilt = A*Pout(mW) equation, for DCM.
Current configurable range: 0 to 10000."
DEFVAL { 0 }
::= { tnAmplifierPortConfigEntry 13 }
tnAmplifierPortMaxFlatGainOffset OBJECT-TYPE
SYNTAX Integer32
UNITS "mB"
MAX-ACCESS read-create
STATUS current
DESCRIPTION "Provides a correction to the assumed max flat
gain value.
Current configurable range: -500 to 500."
DEFVAL { 0 }
::= { tnAmplifierPortConfigEntry 14 }
tnAmplifierPortGainTilt OBJECT-TYPE
SYNTAX Integer32
UNITS "mB"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Current OA tilt setting for the signal port of
the amplifier card.
Current ranges:
AM2625A: -600 to -100
AM2032A: -300 to 0
ASWG: -400 to 400
A4PSWG: -400 to 400."
DEFVAL { 0 }
::= { tnAmplifierPortConfigEntry 15 }
tnAmplifierPortAprHoldOffTime OBJECT-TYPE
SYNTAX INTEGER {
time0ms(1),
-- obsolete
-- time50ms(2),
-- time100ms(3),
time250ms(4)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION "The auto power recovery hold off time."
DEFVAL { time0ms }
::= { tnAmplifierPortConfigEntry 16 }
tnAmplifierPortLosMode OBJECT-TYPE
SYNTAX INTEGER {
auto(1),
losn(2)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION "The Amplifier Port LOS Mode."
DEFVAL { auto }
::= { tnAmplifierPortConfigEntry 17 }
tnAmplifierPortSignalFailThreshold OBJECT-TYPE
SYNTAX Unsigned32 (0..12)
MAX-ACCESS read-create
STATUS current
DESCRIPTION "Integer range 4 to 5, representing 10**4 to 10**5.
Current configurable range: 4 to 5."
DEFVAL { 4 }
::= { tnAmplifierPortConfigEntry 18 }
tnAmplifierPortSignalDegradeThreshold OBJECT-TYPE
SYNTAX Unsigned32 (0..12)
MAX-ACCESS read-create
STATUS current
DESCRIPTION "Integer range 5 to 9, representing 10**5 to 10**9.
Current configurable range: 5 to 9."
DEFVAL { 6 }
::= { tnAmplifierPortConfigEntry 19 }
tnAmplifierPortVoaSet OBJECT-TYPE
SYNTAX Unsigned32
UNITS "mBm"
MAX-ACCESS read-create
STATUS current
DESCRIPTION "The following description applies to the
LINEOUT port of the uni-directionalamplifier
card:
Current configurable range: 0 to 1800."
DEFVAL { 0 }
::= { tnAmplifierPortConfigEntry 20 }
tnAmplifierPortGainRange OBJECT-TYPE
SYNTAX INTEGER {
low(1),
high(2)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION "Gain range for ASWG/A4PSWG cards."
DEFVAL { low }
::= { tnAmplifierPortConfigEntry 21 }
tnAmplifierPortAprMode OBJECT-TYPE
SYNTAX INTEGER {
auto(1),
force(2)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION "APR Mode for ASWG/A4PSWG cards."
DEFVAL { auto }
::= { tnAmplifierPortConfigEntry 22 }
tnAmplifierPortOperatingMode OBJECT-TYPE
SYNTAX INTEGER {
gain(1),
power(2),
maxPower(3)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION "ASE Mode for ASWG/A4PSWG cards.
Set to power (node sets LD to LOSN as well)
Set to gain (node sets LD to LOSA as well)."
DEFVAL { gain }
::= { tnAmplifierPortConfigEntry 23 }
tnAmplifierPortSignalPowerTarget OBJECT-TYPE
SYNTAX Integer32
UNITS "mBm"
MAX-ACCESS read-create
STATUS current
DESCRIPTION "Value used when tnAmplifierPortOperatingMode
is in power mode.
Current configurable range: -400 to 1000."
DEFVAL { 300 }
::= { tnAmplifierPortConfigEntry 24 }
tnAmplifierPortPowerGainL OBJECT-TYPE
SYNTAX Unsigned32
UNITS "mB"
MAX-ACCESS read-create
STATUS current
DESCRIPTION "Specifies the amplifier gain."
::= { tnAmplifierPortConfigEntry 25 }
tnAmplifierPortPowerGainMinL OBJECT-TYPE
SYNTAX Unsigned32
UNITS "mB"
MAX-ACCESS read-create
STATUS current
DESCRIPTION "Specifies the minimum EDFA gain."
::= { tnAmplifierPortConfigEntry 26 }
tnAmplifierPortPowerGainMaxL OBJECT-TYPE
SYNTAX Unsigned32
UNITS "mB"
MAX-ACCESS read-create
STATUS current
DESCRIPTION "Specifies the maximum EDFA gain."
::= { tnAmplifierPortConfigEntry 27}
tnAmplifierPortPowerDeltaMaxL OBJECT-TYPE
SYNTAX Unsigned32
UNITS "mB"
MAX-ACCESS read-create
STATUS current
DESCRIPTION "Specifies the maximum allowed difference between the
provisioned gain and the measured gain before an
alarm is raised."
DEFVAL { 0 }
::= { tnAmplifierPortConfigEntry 28 }
tnAmplifierPortGainRangeL OBJECT-TYPE
SYNTAX INTEGER {
low(1),
high(2)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION "Specifies the EDFA gain range.."
DEFVAL { low }
::= { tnAmplifierPortConfigEntry 29 }
tnAmplifierPortTargetTiltL OBJECT-TYPE
SYNTAX Integer32
UNITS "mB"
MAX-ACCESS read-create
STATUS current
DESCRIPTION "Specifies the amplifier tilt value used by the system."
::= { tnAmplifierPortConfigEntry 30 }
tnAmplifierPortVoaSetL OBJECT-TYPE
SYNTAX Unsigned32
UNITS "mBm"
MAX-ACCESS read-create
STATUS current
DESCRIPTION "Specifies the output VOA setting."
DEFVAL { 0 }
::= { tnAmplifierPortConfigEntry 31 }
tnAmplifierPortGainTiltL OBJECT-TYPE
SYNTAX Integer32
UNITS "mB"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Current OA tilt setting for the signal port of
the amplifier card for L band."
DEFVAL { 0 }
::= { tnAmplifierPortConfigEntry 32 }
tnAmplifierPortPowerGainBackoffL OBJECT-TYPE
SYNTAX Unsigned32
UNITS "mB"
MAX-ACCESS read-create
STATUS current
DESCRIPTION "The following description applies to the signal
port of the amplifier card for L band:
The adjustment made to min/max gain by power
management when commissioning.
Current configurable range: 0 to 1000."
DEFVAL { 0 }
::= { tnAmplifierPortConfigEntry 33 }
tnAmplifierPortPowerSpanRepairMarginL OBJECT-TYPE
SYNTAX Unsigned32
UNITS "mB"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The following description applies to the signal
port of the amplifier card for L Band:
EPT - splice margin.
This is calculated as the absolute value of the
difference between tnAmplifierPortPowerGainMaxL
and tnAmplifierPortPowerGainBackoffL."
::= { tnAmplifierPortConfigEntry 34 }
tnAmplifierPortOperatingModeL OBJECT-TYPE
SYNTAX INTEGER {
gain(1),
power(2),
maxPower(3)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION "ASE Mode for ASWG/A4PSWG cards for L-Band.
Set to power (node sets LD to LOSN as well)
Set to gain (node sets LD to LOSA as well)."
DEFVAL { gain }
::= { tnAmplifierPortConfigEntry 35 }
tnAmplifierPortSignalPowerTargetL OBJECT-TYPE
SYNTAX Integer32
UNITS "mBm"
MAX-ACCESS read-create
STATUS current
DESCRIPTION "Value used when tnAmplifierPortOperatingModeL
is in power mode for L-Band.
Current configurable range: -400 to 1000."
DEFVAL { 300 }
::= { tnAmplifierPortConfigEntry 36 }
tnAmplifierPortUserSelectedExteriorDcmPresentIn OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-create
STATUS current
DESCRIPTION "Manage external DCM."
DEFVAL { false }
::= { tnAmplifierPortConfigEntry 37 }
tnAmplifierPortUserSelectedExteriorDcmPresentOut OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-create
STATUS current
DESCRIPTION "Manage external DCM."
DEFVAL { false }
::= { tnAmplifierPortConfigEntry 38 }
tnAmplifierPortBandMode OBJECT-TYPE
SYNTAX INTEGER {
cBand(1),
lBand(2),
clBand(3)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION "This attribute determines if the LD is operating
in a single or dual band. If in a single band mode,
only the provisioned band attributes are made availabe
to provision and retrieve."
DEFVAL { clBand }
::= { tnAmplifierPortConfigEntry 39 }
tnAmplifierPortLosModeL OBJECT-TYPE
SYNTAX INTEGER {
auto(1),
losn(2)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION "The Amplifier Port LOS Mode in L band."
DEFVAL { auto }
::= { tnAmplifierPortConfigEntry 40 }
tnAmplifierPortBoosterTargetPowerIn OBJECT-TYPE
SYNTAX Integer32
UNITS "mBm"
MAX-ACCESS read-create
STATUS current
DESCRIPTION "Target Power Per Channel.
Current configurable range: -500 to 600."
DEFVAL { -100 }
::= { tnAmplifierPortConfigEntry 41 }
tnAmplifierPortAprEDFApulse OBJECT-TYPE
SYNTAX INTEGER {
on(1),
off(2)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION "APR EDFA Pulsing."
DEFVAL { on }
::= { tnAmplifierPortConfigEntry 42 }
tnAmplifierPortLineDcmConnAddress OBJECT-TYPE
SYNTAX InterfaceIndexOrZero
MAX-ACCESS read-create
STATUS current
DESCRIPTION "."
::= { tnAmplifierPortConfigEntry 43 }
tnAmplifierPortAPREDFAPulseAttempt OBJECT-TYPE
SYNTAX TnCommand
MAX-ACCESS read-create
STATUS current
DESCRIPTION "APR pulse attempt."
DEFVAL { noCmd }
::= { tnAmplifierPortConfigEntry 44 }
tnAmplifierPortSpanLossTh OBJECT-TYPE
SYNTAX Integer32
UNITS "mB"
MAX-ACCESS read-create
STATUS current
DESCRIPTION "Span loss threshold ."
DEFVAL { -9900 }
::= { tnAmplifierPortConfigEntry 45 }
tnAmplifierPortAsellLink OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-create
STATUS current
DESCRIPTION "."
DEFVAL { false }
::= { tnAmplifierPortConfigEntry 46 }
tnAmplifierPortTargetPowerWidth OBJECT-TYPE
SYNTAX NokiaAmpPortTargetPowerWidth
MAX-ACCESS read-create
STATUS current
DESCRIPTION "."
DEFVAL { channelWidth50GHz }
::= { tnAmplifierPortConfigEntry 47 }
tnAmplifierPortTargetPowerWidthL OBJECT-TYPE
SYNTAX NokiaAmpPortTargetPowerWidth
MAX-ACCESS read-create
STATUS current
DESCRIPTION "."
DEFVAL { channelWidth50GHz }
::= { tnAmplifierPortConfigEntry 48 }
tnAmplifierPortAsellLinkL OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-create
STATUS current
DESCRIPTION "."
DEFVAL { false }
::= { tnAmplifierPortConfigEntry 49 }
--------------------------------------------------------------------------------
-- Hybrid Amplifier Port Config Scalars
--------------------------------------------------------------------------------
tnAmplifierHybridPortConfigAttributeTotal OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Total number of attributes in
tnAmplifierHybridPortConfigTable."
::= { tnAmplifierPortConfig 3 }
--------------------------------------------------------------------------------
-- Hybrid Amplifier Port Config Table
--------------------------------------------------------------------------------
tnAmplifierHybridPortConfigTable OBJECT-TYPE
SYNTAX SEQUENCE OF TnAmplifierHybridPortConfigEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The provisioned ports on an hybrid amplifier
card."
::= { tnAmplifierPortConfig 4 }
tnAmplifierHybridPortConfigEntry OBJECT-TYPE
SYNTAX TnAmplifierHybridPortConfigEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "."
INDEX { ifIndex }
::= { tnAmplifierHybridPortConfigTable 1 }
TnAmplifierHybridPortConfigEntry ::= SEQUENCE {
tnAmplifierHybridPortVoaAttenuation Unsigned32,
tnAmplifierHybridPortInitialMidLoss Unsigned32,
tnAmplifierHybridPortInitialAgcTargetGain Unsigned32,
tnAmplifierHybridPortVoaMinAttenuation Unsigned32,
tnAmplifierHybridPortVoaMaxAttenuation Unsigned32
}
tnAmplifierHybridPortVoaAttenuation OBJECT-TYPE
SYNTAX Unsigned32
UNITS "mB"
MAX-ACCESS read-create
STATUS current
DESCRIPTION "Hybrid amplifier port VOA attenuation.
Current configurable range: 0 to 2000."
DEFVAL { 0 }
::= { tnAmplifierHybridPortConfigEntry 1 }
tnAmplifierHybridPortInitialMidLoss OBJECT-TYPE
SYNTAX Unsigned32
UNITS "mB"
MAX-ACCESS read-create
STATUS current
DESCRIPTION "Hybrid amplifier port initial VOA attenuation.
Current configurable range: 0 to 2000."
DEFVAL { 60 }
::= { tnAmplifierHybridPortConfigEntry 2 }
tnAmplifierHybridPortInitialAgcTargetGain OBJECT-TYPE
SYNTAX Unsigned32
UNITS "mB"
MAX-ACCESS read-create
STATUS current
DESCRIPTION "Hybrid amplifier port initial AGC target gain.
Current configurable range: 200 to 2000."
DEFVAL { 1000 }
::= { tnAmplifierHybridPortConfigEntry 3 }
tnAmplifierHybridPortVoaMinAttenuation OBJECT-TYPE
SYNTAX Unsigned32
UNITS "mB"
MAX-ACCESS read-create
STATUS current
DESCRIPTION "Hybrid amplifier port VOA minimum attenuation.
Current configurable range: 0 to 2000."
DEFVAL { 0 }
::= { tnAmplifierHybridPortConfigEntry 4 }
tnAmplifierHybridPortVoaMaxAttenuation OBJECT-TYPE
SYNTAX Unsigned32
UNITS "mB"
MAX-ACCESS read-create
STATUS current
DESCRIPTION "Hybrid amplifier port VOA maximum attenuation.
Current configurable range: 0 to 2000."
DEFVAL { 2000 }
::= { tnAmplifierHybridPortConfigEntry 5 }
--------------------------------------------------------------------------------
-- Amplifier Port Info Scalars
--------------------------------------------------------------------------------
tnAmplifierPortInfoAttributeTotal OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Total number of attributes in
tnAmplifierPortInfoTable."
::= { tnAmplifierPortInfo 1 }
--------------------------------------------------------------------------------
-- Amplifier Port Info Table
--------------------------------------------------------------------------------
tnAmplifierPortInfoTable OBJECT-TYPE
SYNTAX SEQUENCE OF TnAmplifierPortInfoEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The equipped ports on an amplifier card."
::= { tnAmplifierPortInfo 2 }
tnAmplifierPortInfoEntry OBJECT-TYPE
SYNTAX TnAmplifierPortInfoEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "."
INDEX { ifIndex }
::= { tnAmplifierPortInfoTable 1 }
TnAmplifierPortInfoEntry ::= SEQUENCE {
tnAmplifierPortInternalAmpModuleTemperature Integer32,
tnAmplifierPortPowerIn Integer32,
tnAmplifierPortPowerOut Integer32,
tnAmplifierPortSignalPowerOut Integer32,
tnAmplifierPortInputToOutputGain Integer32,
tnAmplifierPortDCMInPower Integer32,
tnAmplifierPortDCMOutPower Integer32,
tnAmplifierPortActualTilt Integer32,
tnAmplifierPortWtOcmMonitorPortOut Unsigned32,
tnAmplifierPortOSCTxPowerIn Integer32,
tnAmplifierPortOSCTxPowerOut Integer32,
tnAmplifierPortTestingActive TruthValue,
tnAmplifierCommonEgressOutputPower Integer32,
tnAmplifierActOutAtten Unsigned32,
tnAmplifierCommonEgressOutputPowerL Integer32,
tnAmplifierActOutAttenL Unsigned32,
tnAmplifierPortActualTiltL Integer32,
tnAmplifierPortSignalPowerOutL Integer32,
tnAmplifierPortInputToOutputGainL Integer32,
tnAmplifierPortOSCTxPowerOutL Integer32,
tnAmplifierPortPowerInL Integer32,
tnAmplifierPortInfoOSCRxPowerIn Integer32,
tnAmplifierPortInfoOSCSfpTxPowerOut Integer32,
tnAmplifierPortInfoOSCSfpRxPowerIn Integer32,
tnAmplifierPortBoosterTargetPowerOut Integer32,
tnAmplifierPortPowerOutL Integer32,
tnAmplifierPortSpanLoss Integer32,
tnAmplifierPortAprEDFApulsePower Unsigned32
}
tnAmplifierPortInternalAmpModuleTemperature OBJECT-TYPE
SYNTAX Integer32
UNITS "Celsius"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The following description applies to the
signal port of the amplifier card:
The temperature of the laser.
Current range: -5 to 35."
DEFVAL { 30 }
::= { tnAmplifierPortInfoEntry 1 }
tnAmplifierPortPowerIn OBJECT-TYPE
SYNTAX Integer32
UNITS "mBm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The following description applies to the
fromDcm and line ports of the amplifier card:
The total input power
Current ranges:
ASWG: -9900, -3600 to 1700
A4PSWG: -9900, -3600 to 1700."
::= { tnAmplifierPortInfoEntry 2 }
tnAmplifierPortPowerOut OBJECT-TYPE
SYNTAX Integer32
UNITS "mBm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The following description applies to the
signal and toDcm ports of the amplifier card:
The total output power.
Current ranges:
AM2625A: -9900, -900 to 2900
AM2032A: -9900, -300 to 2300
ASWG: -9900, -1100 to 2550
A4PSWG: -9900, -1100 to 2550."
::= { tnAmplifierPortInfoEntry 3 }
tnAmplifierPortSignalPowerOut OBJECT-TYPE
SYNTAX Integer32
UNITS "mBm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The following description applies to the
signal port of the amplifier card:
The total input power plus the programmed gain.
Current Ranges:
ASWG: -9900, -1100 to 2550
A4PSWG: -9900, -1100 to 2550."
::= { tnAmplifierPortInfoEntry 4 }
tnAmplifierPortInputToOutputGain OBJECT-TYPE
SYNTAX Integer32
UNITS "mB"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The following description applies to the
LINEOUT port of the uni-directional amplifier
card.
Current Ranges:
ASWG: -9900, -300 to 2900
A4PSWG: -9900, -300 to 2900."
::= { tnAmplifierPortInfoEntry 5 }
tnAmplifierPortDCMInPower OBJECT-TYPE
SYNTAX Integer32
UNITS "mBm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The following description applies to the DCM
In port of the amplifier card. -9900 indicates
no measured power.
Current range: -9900, -3000 to 2000."
DEFVAL { -9900 }
::= { tnAmplifierPortInfoEntry 6 }
tnAmplifierPortDCMOutPower OBJECT-TYPE
SYNTAX Integer32
UNITS "mBm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The following description applies to the DCM
Out port of the amplifier card. -9900 indicates
no measured power.
Current range: -9900, -3000 to 2000."
DEFVAL { -9900 }
::= { tnAmplifierPortInfoEntry 7 }
tnAmplifierPortActualTilt OBJECT-TYPE
SYNTAX Integer32
UNITS "mB"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The following description applies to the
signal port of the amplifier card:
Current range: -1000 to 500."
::= { tnAmplifierPortInfoEntry 8 }
tnAmplifierPortWtOcmMonitorPortOut OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The associated WTOCM In port associated to the LD.
Current range: 0 to 0xFFFFFFFF."
DEFVAL { 0 }
::= { tnAmplifierPortInfoEntry 9 }
tnAmplifierPortOSCTxPowerIn OBJECT-TYPE
SYNTAX Integer32
UNITS "mBm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The EDFA module OSC transmitted input power of
the amplifier card. -9900 indicates no measured
power.
Current ranges:
A2P2125: -1500 to 1100
AM2032A: -1500 to 1100
AM2125A: -1500 to 1100
AM2125B: -1500 to 1100
AM2318A: -1500 to 1100
AM2625A: -2000 to 1100
ASWG: -1500 to 1100
A4PSWG: -1500 to 1100."
DEFVAL { -9900 }
::= { tnAmplifierPortInfoEntry 10 }
tnAmplifierPortOSCTxPowerOut OBJECT-TYPE
SYNTAX Integer32
UNITS "mBm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The EDFA module OSC transmitted output power of
the amplifier card. -9900 indicates no measured
power.
Current ranges:
A2P2125: -1500 to 1100
AA2DONW: -1500 to 1500
AM2032A: -1500 to 1100
AM2125A: -1500 to 1100
AM2125B: -1500 to 1100
AM2318A: -1500 to 1100
AM2625A: 0 to 1500
ASWG: -1500 to 1100
A4PSWG: -1500 to 1100."
DEFVAL { -9900 }
::= { tnAmplifierPortInfoEntry 11 }
tnAmplifierPortTestingActive OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Node sets to true when testing in progress
on port (logic)."
DEFVAL { false }
::= { tnAmplifierPortInfoEntry 12 }
tnAmplifierCommonEgressOutputPower OBJECT-TYPE
SYNTAX Integer32
UNITS "mBm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Calculated in scot when tiltadj is triggered.Referes to the
Target output power per channel,adjusted for the C+L Interaction."
::= { tnAmplifierPortInfoEntry 13 }
tnAmplifierActOutAtten OBJECT-TYPE
SYNTAX Unsigned32
UNITS "mB"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Actual amplifier attenuation available on the AWBxx packs only."
DEFVAL { 0 }
::= { tnAmplifierPortInfoEntry 14 }
tnAmplifierCommonEgressOutputPowerL OBJECT-TYPE
SYNTAX Integer32
UNITS "mBm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Calculated in scot when tiltadj is triggered.Referes to the
Target output power per channel,adjusted for the C+L Interaction."
::= { tnAmplifierPortInfoEntry 15 }
tnAmplifierActOutAttenL OBJECT-TYPE
SYNTAX Unsigned32
UNITS "mB"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Actual amplifier attenuation available on the AWBxx packs only
for L Band."
DEFVAL { 0 }
::= { tnAmplifierPortInfoEntry 16 }
tnAmplifierPortActualTiltL OBJECT-TYPE
SYNTAX Integer32
UNITS "mB"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The following description applies to the
signal port of the amplifier card for L band:
Current range: -1000 to 500."
::= { tnAmplifierPortInfoEntry 17 }
tnAmplifierPortSignalPowerOutL OBJECT-TYPE
SYNTAX Integer32
UNITS "mBm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The following description applies to the
signal port of the amplifier card for L band:
The total input power plus the programmed gain."
::= { tnAmplifierPortInfoEntry 18 }
tnAmplifierPortInputToOutputGainL OBJECT-TYPE
SYNTAX Integer32
UNITS "mB"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The following description applies to the
LINEOUT port of the uni-directional amplifier
card for L band."
::= { tnAmplifierPortInfoEntry 19 }
tnAmplifierPortOSCTxPowerOutL OBJECT-TYPE
SYNTAX Integer32
UNITS "mBm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The EDFA module OSC transmitted output power of
the amplifier card. -9900 indicates no measured
power."
DEFVAL { -9900 }
::= { tnAmplifierPortInfoEntry 20 }
tnAmplifierPortPowerInL OBJECT-TYPE
SYNTAX Integer32
UNITS "mBm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "EDFA module total input power L band."
::= { tnAmplifierPortInfoEntry 21 }
tnAmplifierPortInfoOSCRxPowerIn OBJECT-TYPE
SYNTAX Integer32
UNITS "mBm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The EDFA module OSC received input power to the card.
-9900 indicates no measured power."
::= { tnAmplifierPortInfoEntry 22 }
tnAmplifierPortInfoOSCSfpTxPowerOut OBJECT-TYPE
SYNTAX Integer32
UNITS "mBm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The OSCSFP transceiver output power -9900 indicates
no measured power."
::= { tnAmplifierPortInfoEntry 23 }
tnAmplifierPortInfoOSCSfpRxPowerIn OBJECT-TYPE
SYNTAX Integer32
UNITS "mBm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The OSCSFP transceiver input power -9900 indicates no
measured power."
::= { tnAmplifierPortInfoEntry 24 }
tnAmplifierPortBoosterTargetPowerOut OBJECT-TYPE
SYNTAX Integer32
UNITS "mBm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Target Power Per Channel."
::= { tnAmplifierPortInfoEntry 25 }
tnAmplifierPortPowerOutL OBJECT-TYPE
SYNTAX Integer32
UNITS "mBm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Total output power for L Band."
::= { tnAmplifierPortInfoEntry 26 }
tnAmplifierPortSpanLoss OBJECT-TYPE
SYNTAX Integer32
UNITS "mB"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Span loss."
DEFVAL { 9900 }
::= { tnAmplifierPortInfoEntry 27 }
tnAmplifierPortAprEDFApulsePower OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Apr EDFA pulse Power."
::= { tnAmplifierPortInfoEntry 28 }
--------------------------------------------------------------------------------
-- Amplifier MESH Port Info Scalars
--------------------------------------------------------------------------------
tnAmplifierMeshPortInfoAttributeTotal OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Total number of attributes in
tnAmplifierMeshPortInfoTable."
::= { tnAmplifierPortInfo 3 }
--------------------------------------------------------------------------------
-- Amplifier Mesh Port Info Table
--------------------------------------------------------------------------------
tnAmplifierMeshPortInfoTable OBJECT-TYPE
SYNTAX SEQUENCE OF TnAmplifierMeshPortInfoEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The equipped ports on a mesh card."
::= { tnAmplifierPortInfo 4 }
tnAmplifierMeshPortInfoEntry OBJECT-TYPE
SYNTAX TnAmplifierMeshPortInfoEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "."
INDEX { ifIndex }
::= { tnAmplifierMeshPortInfoTable 1 }
TnAmplifierMeshPortInfoEntry ::=
SEQUENCE {
tnAmplifierMeshPortPowerOut Integer32,
tnAmplifierMeshPortSignalPowerOut Integer32,
tnAmplifierMeshPortInputToOutputGain Integer32
}
tnAmplifierMeshPortPowerOut OBJECT-TYPE
SYNTAX Integer32
UNITS "mBm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The following description applies to the output
port of the mesh card:
The total output power.
-9900 indicates no measured power."
DEFVAL { -9900 }
::= { tnAmplifierMeshPortInfoEntry 1 }
tnAmplifierMeshPortSignalPowerOut OBJECT-TYPE
SYNTAX Integer32
UNITS "mBm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The following description applies to the
output port of the mesh card:
The total input power plus the programmed gain.
-9900 indicates no measured power."
DEFVAL { -9900 }
::= { tnAmplifierMeshPortInfoEntry 2 }
tnAmplifierMeshPortInputToOutputGain OBJECT-TYPE
SYNTAX Integer32
UNITS "mB"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The following description reports the gain from
sigIn to sigOut ports of the MESH4 card:
OA module gain - EVOA loss - SEEPROM loss of
splitter.
Current range:
MESH4: -1100 to 2400."
DEFVAL { 700 }
::= { tnAmplifierMeshPortInfoEntry 3 }
--------------------------------------------------------------------------------
-- Hybrid Amplifier Port Info Scalars
--------------------------------------------------------------------------------
tnAmplifierHybridPortInfoAttributeTotal OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Total number of attributes in
tnAmplifierHybridPortInfoTable."
::= { tnAmplifierPortInfo 5 }
--------------------------------------------------------------------------------
-- Hybrid Amplifier Port Info Table
--------------------------------------------------------------------------------
tnAmplifierHybridPortInfoTable OBJECT-TYPE
SYNTAX SEQUENCE OF TnAmplifierHybridPortInfoEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The equipped ports on an hybrid amplifier card."
::= { tnAmplifierPortInfo 6 }
tnAmplifierHybridPortInfoEntry OBJECT-TYPE
SYNTAX TnAmplifierHybridPortInfoEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "."
INDEX { ifIndex }
::= { tnAmplifierHybridPortInfoTable 1 }
TnAmplifierHybridPortInfoEntry ::= SEQUENCE {
tnAmplifierHybridPortInternalAmpModuleTemperature Unsigned32
}
tnAmplifierHybridPortInternalAmpModuleTemperature OBJECT-TYPE
SYNTAX Unsigned32
UNITS "Celsius"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Hybrid Amplifier Port Internal Module Temperature."
::= { tnAmplifierHybridPortInfoEntry 1 }
--------------------------------------------------------------------------------
-- Amplifier Card Info Scalars
--------------------------------------------------------------------------------
tnAmplifierCardInfoAttributeTotal OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Total number of attributes in
tnAmplifierCardInfoTable."
::= { tnAmplifierCardInfo 1 }
--------------------------------------------------------------------------------
-- Amplifier Card Info Table
--------------------------------------------------------------------------------
tnAmplifierCardInfoTable OBJECT-TYPE
SYNTAX SEQUENCE OF TnAmplifierCardInfoEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The equipped pumps and other values on an
amplifier card."
::= { tnAmplifierCardInfo 2 }
tnAmplifierCardInfoEntry OBJECT-TYPE
SYNTAX TnAmplifierCardInfoEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "."
INDEX { tnShelfIndex,
tnSlotIndex }
::= { tnAmplifierCardInfoTable 1 }
TnAmplifierCardInfoEntry ::= SEQUENCE {
tnAmplifierCardOAMPump1Temperature Integer32,
tnAmplifierCardOAMPump2Temperature Integer32,
tnAmplifierCardOAMPump3Temperature Integer32,
tnAmplifierCardOAMPump1Bias Integer32,
tnAmplifierCardOAMPump2Bias Integer32,
tnAmplifierCardOAMPump3Bias Integer32,
tnAmplifierCardOptIntSpanLoss Integer32,
tnAmplifierCardOAMPump4Temperature Integer32,
tnAmplifierCardOAMPump5Temperature Integer32,
tnAmplifierCardOAMPump6Temperature Integer32,
tnAmplifierCardOAMPump4Bias Integer32,
tnAmplifierCardOAMPump5Bias Integer32,
tnAmplifierCardOAMPump6Bias Integer32,
tnAmplifierCardOAMLPump1Temperature Integer32,
tnAmplifierCardOAMLPump2Temperature Integer32,
tnAmplifierCardOAMLPump3Temperature Integer32,
tnAmplifierCardOAMLPump4Temperature Integer32,
tnAmplifierCardOAMLPump1Bias Integer32,
tnAmplifierCardOAMLPump2Bias Integer32,
tnAmplifierCardOAMLPump3Bias Integer32,
tnAmplifierCardOAMLPump4Bias Integer32,
tnAmplifierCardOAM1PumpTemperatures SnmpAdminString,
tnAmplifierCardOAM2PumpTemperatures SnmpAdminString,
tnAmplifierCardOAM1PumpBiases SnmpAdminString,
tnAmplifierCardOAM2PumpBiases SnmpAdminString,
tnAmplifierCardOAM3PumpTemperatures SnmpAdminString,
tnAmplifierCardOAM3PumpBiases SnmpAdminString
}
tnAmplifierCardOAMPump1Temperature OBJECT-TYPE
SYNTAX Integer32
UNITS "Celsius"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The current temperature of the OA Laser Pump 1."
::= { tnAmplifierCardInfoEntry 1 }
tnAmplifierCardOAMPump2Temperature OBJECT-TYPE
SYNTAX Integer32
UNITS "Celsius"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The current temperature of the OA Laser Pump 2."
::= { tnAmplifierCardInfoEntry 2 }
tnAmplifierCardOAMPump3Temperature OBJECT-TYPE
SYNTAX Integer32
UNITS "Celsius"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The current temperature of the OA Laser Pump 3."
::= { tnAmplifierCardInfoEntry 3 }
tnAmplifierCardOAMPump1Bias OBJECT-TYPE
SYNTAX Integer32
UNITS "mA"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The current bias of the OA Laser Pump 1."
::= { tnAmplifierCardInfoEntry 4 }
tnAmplifierCardOAMPump2Bias OBJECT-TYPE
SYNTAX Integer32
UNITS "mA"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The current bias of the OA Laser Pump 2."
::= { tnAmplifierCardInfoEntry 5 }
tnAmplifierCardOAMPump3Bias OBJECT-TYPE
SYNTAX Integer32
UNITS "mA"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The current bias of the OA Laser Pump 3."
::= { tnAmplifierCardInfoEntry 6 }
tnAmplifierCardOptIntSpanLoss OBJECT-TYPE
SYNTAX Integer32
UNITS "mB"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The span loss value.
Current range: 0 to 9900."
DEFVAL { 9900 }
::= { tnAmplifierCardInfoEntry 7 }
tnAmplifierCardOAMPump4Temperature OBJECT-TYPE
SYNTAX Integer32
UNITS "Celsius"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The current temperature of the OA Laser Pump 4."
::= { tnAmplifierCardInfoEntry 8 }
tnAmplifierCardOAMPump5Temperature OBJECT-TYPE
SYNTAX Integer32
UNITS "Celsius"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The current temperature of the OA Laser Pump 5."
::= { tnAmplifierCardInfoEntry 9 }
tnAmplifierCardOAMPump6Temperature OBJECT-TYPE
SYNTAX Integer32
UNITS "Celsius"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The current temperature of the OA Laser Pump 6."
::= { tnAmplifierCardInfoEntry 10 }
tnAmplifierCardOAMPump4Bias OBJECT-TYPE
SYNTAX Integer32
UNITS "mA"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The current bias of the OA Laser Pump 4."
::= { tnAmplifierCardInfoEntry 11 }
tnAmplifierCardOAMPump5Bias OBJECT-TYPE
SYNTAX Integer32
UNITS "mA"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The current bias of the OA Laser Pump 5."
::= { tnAmplifierCardInfoEntry 12 }
tnAmplifierCardOAMPump6Bias OBJECT-TYPE
SYNTAX Integer32
UNITS "mA"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The current bias of the OA Laser Pump 6."
::= { tnAmplifierCardInfoEntry 13 }
tnAmplifierCardOAMLPump1Temperature OBJECT-TYPE
SYNTAX Integer32
UNITS "Celsius"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The current temperature of the OA Laser Pump 1 for L Band."
::= { tnAmplifierCardInfoEntry 14 }
tnAmplifierCardOAMLPump2Temperature OBJECT-TYPE
SYNTAX Integer32
UNITS "Celsius"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The current temperature of the OA Laser Pump 2 for L Band."
::= { tnAmplifierCardInfoEntry 15 }
tnAmplifierCardOAMLPump3Temperature OBJECT-TYPE
SYNTAX Integer32
UNITS "Celsius"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The current temperature of the OA Laser Pump 3 for L Band."
::= { tnAmplifierCardInfoEntry 16 }
tnAmplifierCardOAMLPump4Temperature OBJECT-TYPE
SYNTAX Integer32
UNITS "Celsius"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The current temperature of the OA Laser Pump 4 for L Band."
::= { tnAmplifierCardInfoEntry 17 }
tnAmplifierCardOAMLPump1Bias OBJECT-TYPE
SYNTAX Integer32
UNITS "mA"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The current bias of the OA Laser Pump 1 for L Band."
::= { tnAmplifierCardInfoEntry 18 }
tnAmplifierCardOAMLPump2Bias OBJECT-TYPE
SYNTAX Integer32
UNITS "mA"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The current bias of the OA Laser Pump 2 for L Band."
::= { tnAmplifierCardInfoEntry 19 }
tnAmplifierCardOAMLPump3Bias OBJECT-TYPE
SYNTAX Integer32
UNITS "mA"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The current bias of the OA Laser Pump 3 for L Band."
::= { tnAmplifierCardInfoEntry 20 }
tnAmplifierCardOAMLPump4Bias OBJECT-TYPE
SYNTAX Integer32
UNITS "mA"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The current bias of the OA Laser Pump 4 for L Band."
::= { tnAmplifierCardInfoEntry 21 }
tnAmplifierCardOAM1PumpTemperatures OBJECT-TYPE
SYNTAX SnmpAdminString (SIZE(0..512))
MAX-ACCESS read-only
STATUS current
DESCRIPTION "String containing number of pumps for the 1st optical
amplifier on the card, followed by the pump temperature
for each pump. For IROADM9R OAM1 is the ingress OA module."
::= { tnAmplifierCardInfoEntry 22 }
tnAmplifierCardOAM2PumpTemperatures OBJECT-TYPE
SYNTAX SnmpAdminString (SIZE(0..512))
MAX-ACCESS read-only
STATUS current
DESCRIPTION "String containing number of pumps for the 2nd OA module
on the card, followed by the pump temperature for each
pump. For IROADM9R OAM2 is the egress OA module."
::= { tnAmplifierCardInfoEntry 23 }
tnAmplifierCardOAM1PumpBiases OBJECT-TYPE
SYNTAX SnmpAdminString (SIZE(0..512))
MAX-ACCESS read-only
STATUS current
DESCRIPTION "String containing number of pumps for the 1st optical
amplifier on the card, followed by the pump bias current
for each pump. For IROADM9R OAM1 is the ingress OA module."
::= { tnAmplifierCardInfoEntry 24 }
tnAmplifierCardOAM2PumpBiases OBJECT-TYPE
SYNTAX SnmpAdminString (SIZE(0..512))
MAX-ACCESS read-only
STATUS current
DESCRIPTION "String containing number of pumps for the 2nd optical
amplifier on the card, followed by the pump bias current
for each pump. For IROADM9R OAM2 is the egress OA module."
::= { tnAmplifierCardInfoEntry 25 }
tnAmplifierCardOAM3PumpTemperatures OBJECT-TYPE
SYNTAX SnmpAdminString (SIZE(0..512))
MAX-ACCESS read-only
STATUS current
DESCRIPTION "String containing number of pumps for the 3rd OA module
on the card, followed by the pump temperature for each
pump."
::= { tnAmplifierCardInfoEntry 26 }
tnAmplifierCardOAM3PumpBiases OBJECT-TYPE
SYNTAX SnmpAdminString (SIZE(0..512))
MAX-ACCESS read-only
STATUS current
DESCRIPTION "String containing number of pumps for the 3rd optical
amplifier on the card, followed by the pump bias current
for each pump."
::= { tnAmplifierCardInfoEntry 27 }
--------------------------------------------------------------------------------
-- Mesh Amplifier Card Info Scalars
--------------------------------------------------------------------------------
tnAmplifierMeshCardInfoAttributeTotal OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Total number of attributes in
tnAmplifierMeshCardInfoTable."
::= { tnAmplifierCardInfo 3 }
--------------------------------------------------------------------------------
-- Mesh Amplifier Card Info Table
--------------------------------------------------------------------------------
tnAmplifierMeshCardInfoTable OBJECT-TYPE
SYNTAX SEQUENCE OF TnAmplifierMeshCardInfoEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The measured values on an amplifier module in
a mesh card."
::= { tnAmplifierCardInfo 4 }
tnAmplifierMeshCardInfoEntry OBJECT-TYPE
SYNTAX TnAmplifierMeshCardInfoEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "."
INDEX { tnShelfIndex,
tnSlotIndex }
::= { tnAmplifierMeshCardInfoTable 1 }
TnAmplifierMeshCardInfoEntry ::= SEQUENCE {
tnAmplifierMeshCardInternalTemperature Integer32,
tnAmplifierMeshCardPowerIn Integer32,
tnAmplifierMeshCardPowerOut Integer32,
tnAmplifierMeshCardSignalPowerOut Integer32,
tnAmplifierMeshCardInputToOutputGain Integer32,
tnAmplifierMeshCardGainTilt Integer32,
tnAmplifierMeshCardActualTilt Integer32
}
tnAmplifierMeshCardInternalTemperature OBJECT-TYPE
SYNTAX Integer32
UNITS "Celsius"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The following description applies to the
amplifier module in the mesh card:
The temperature of the laser.
Current range:
MESH4: -5 to 35."
DEFVAL { 30 }
::= { tnAmplifierMeshCardInfoEntry 1 }
tnAmplifierMeshCardPowerIn OBJECT-TYPE
SYNTAX Integer32
UNITS "mBm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The following description applies to the input
port of the amplifier module in the mesh card:
The total input power.
-9900 indicates no measured power."
::= { tnAmplifierMeshCardInfoEntry 2 }
tnAmplifierMeshCardPowerOut OBJECT-TYPE
SYNTAX Integer32
UNITS "mBm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The following description applies to the output
port of the amplifier module in the mesh card:
The total output power.
-9900 indicates no measured power."
::= { tnAmplifierMeshCardInfoEntry 3 }
tnAmplifierMeshCardSignalPowerOut OBJECT-TYPE
SYNTAX Integer32
UNITS "mBm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The following description applies to the output
port of the amplifier module in the mesh card:
The total input power plus the programmed gain.
-9900 indicates no measured power."
::= { tnAmplifierMeshCardInfoEntry 4 }
tnAmplifierMeshCardInputToOutputGain OBJECT-TYPE
SYNTAX Integer32
UNITS "mB"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The following description applies to the output
port of the amplifier module in the mesh card:
Current range:
MESH4: -1100 to 2400."
DEFVAL { 700 }
::= { tnAmplifierMeshCardInfoEntry 5 }
tnAmplifierMeshCardGainTilt OBJECT-TYPE
SYNTAX Integer32
UNITS "mB"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Current OA tilt setting for the output port of
the amplifier module in the mesh card."
::= { tnAmplifierMeshCardInfoEntry 6 }
tnAmplifierMeshCardActualTilt OBJECT-TYPE
SYNTAX Integer32
UNITS "mB"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The following description applies to the output
port of the amplifier module in the mesh card:
Current range:
MESH4: -1000 to 500."
::= { tnAmplifierMeshCardInfoEntry 7 }
--------------------------------------------------------------------------------
-- Hybrid Amplifier Card Info Scalars
--------------------------------------------------------------------------------
tnAmplifierHybridCardInfoAttributeTotal OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Total number of attributes in
tnAmplifierHybridCardInfoTable."
::= { tnAmplifierCardInfo 5 }
--------------------------------------------------------------------------------
-- Hybrid Amplifier Card Info Table
--------------------------------------------------------------------------------
tnAmplifierHybridCardInfoTable OBJECT-TYPE
SYNTAX SEQUENCE OF TnAmplifierHybridCardInfoEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The measured values on an amplifier module in
a mesh card."
::= { tnAmplifierCardInfo 6 }
tnAmplifierHybridCardInfoEntry OBJECT-TYPE
SYNTAX TnAmplifierHybridCardInfoEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "."
INDEX { tnShelfIndex,
tnSlotIndex }
::= { tnAmplifierHybridCardInfoTable 1 }
TnAmplifierHybridCardInfoEntry ::= SEQUENCE {
tnAmplifierHybridCardOAMPump1Temperature Integer32,
tnAmplifierHybridCardOAMPump2Temperature Integer32,
tnAmplifierHybridCardOAMPump1Bias Integer32,
tnAmplifierHybridCardOAMPump2Bias Integer32,
tnAmplifierHybridCardOAMPump3Temperature Integer32,
tnAmplifierHybridCardOAMPump4Temperature Integer32,
tnAmplifierHybridCardOAMPump3Bias Integer32,
tnAmplifierHybridCardOAMPump4Bias Integer32
}
tnAmplifierHybridCardOAMPump1Temperature OBJECT-TYPE
SYNTAX Integer32
UNITS "Celsius"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The current temperature of the OA Laser Pump 1."
::= { tnAmplifierHybridCardInfoEntry 1 }
tnAmplifierHybridCardOAMPump2Temperature OBJECT-TYPE
SYNTAX Integer32
UNITS "Celsius"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The current temperature of the OA Laser Pump 2."
::= { tnAmplifierHybridCardInfoEntry 2 }
tnAmplifierHybridCardOAMPump1Bias OBJECT-TYPE
SYNTAX Integer32
UNITS "mA"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The current bias of the OA Laser Pump 1."
DEFVAL { 0 }
::= { tnAmplifierHybridCardInfoEntry 3 }
tnAmplifierHybridCardOAMPump2Bias OBJECT-TYPE
SYNTAX Integer32
UNITS "mA"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The current bias of the OA Laser Pump 2."
DEFVAL { 0 }
::= { tnAmplifierHybridCardInfoEntry 4 }
tnAmplifierHybridCardOAMPump3Temperature OBJECT-TYPE
SYNTAX Integer32
UNITS "Celsius"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The current temperature of the OA Laser Pump 3."
::= { tnAmplifierHybridCardInfoEntry 5 }
tnAmplifierHybridCardOAMPump4Temperature OBJECT-TYPE
SYNTAX Integer32
UNITS "Celsius"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The current temperature of the OA Laser Pump 4."
::= { tnAmplifierHybridCardInfoEntry 6 }
tnAmplifierHybridCardOAMPump3Bias OBJECT-TYPE
SYNTAX Integer32
UNITS "mA"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The current bias of the OA Laser Pump 3."
DEFVAL { 0 }
::= { tnAmplifierHybridCardInfoEntry 7 }
tnAmplifierHybridCardOAMPump4Bias OBJECT-TYPE
SYNTAX Integer32
UNITS "mA"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The current bias of the OA Laser Pump 4."
DEFVAL { 0 }
::= { tnAmplifierHybridCardInfoEntry 8 }
--------------------------------------------------------------------------------
-- Amplifier Card Config Scalars
--------------------------------------------------------------------------------
tnAmplifierCardConfigAttributeTotal OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Total number of attributes in
tnAmplifierCardConfigTable."
::= { tnAmplifierCardConfig 1 }
--------------------------------------------------------------------------------
-- Amplifier Card Config Table
--------------------------------------------------------------------------------
tnAmplifierCardConfigTable OBJECT-TYPE
SYNTAX SEQUENCE OF TnAmplifierCardConfigEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The configurable values on an amplifier card."
::= { tnAmplifierCardConfig 2 }
tnAmplifierCardConfigEntry OBJECT-TYPE
SYNTAX TnAmplifierCardConfigEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "."
INDEX { tnShelfIndex,
tnSlotIndex }
::= { tnAmplifierCardConfigTable 1 }
TnAmplifierCardConfigEntry ::= SEQUENCE {
tnAmplifierCardOptIntDetection INTEGER,
tnAmplifierCardOptIntBaseline Integer32,
tnAmplifierCardOptIntLossThreshold Integer32,
tnAmplifierCardOptIntPollPeriod Integer32,
tnAmplifierCardOptIntClearAlarm TnCommand,
tnAmplifierCardAsonAddDropPlannedForOps TruthValue
}
tnAmplifierCardOptIntDetection OBJECT-TYPE
SYNTAX INTEGER {
on(1),
off(2)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION "The status of the Optical Intrusion detection
feature."
DEFVAL { off }
::= { tnAmplifierCardConfigEntry 1 }
tnAmplifierCardOptIntBaseline OBJECT-TYPE
SYNTAX Integer32
UNITS "mBm"
MAX-ACCESS read-create
STATUS current
DESCRIPTION "The optical intrusion baseline value, with -100
means no value has been set.
Current configurable range: -100, 100 to 5000."
DEFVAL { -100 }
::= { tnAmplifierCardConfigEntry 2 }
tnAmplifierCardOptIntLossThreshold OBJECT-TYPE
SYNTAX Integer32
UNITS "mBm"
MAX-ACCESS read-create
STATUS current
DESCRIPTION "The optical intrusion loss threshold value.
Current configurable range: 100 to 500."
DEFVAL { 150 }
::= { tnAmplifierCardConfigEntry 3 }
tnAmplifierCardOptIntPollPeriod OBJECT-TYPE
SYNTAX Integer32
UNITS "seconds"
MAX-ACCESS read-create
STATUS current
DESCRIPTION "The optical intrusion poll period.
Current configurable range: 20 to 120."
DEFVAL { 30 }
::= { tnAmplifierCardConfigEntry 4 }
tnAmplifierCardOptIntClearAlarm OBJECT-TYPE
SYNTAX TnCommand
MAX-ACCESS read-create
STATUS current
DESCRIPTION "Clears optical intrusion alarm."
DEFVAL { noCmd }
::= { tnAmplifierCardConfigEntry 5 }
tnAmplifierCardAsonAddDropPlannedForOps OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-create
STATUS current
DESCRIPTION "Used for ASON nodes running GMRE. The value
indicates if an LD defining the add/drop block
has been planned to accept OPSA OCH protected
services."
DEFVAL { false }
::= { tnAmplifierCardConfigEntry 6 }
--------------------------------------------------------------------------------
-- Mesh Amplifier Card Config Scalars
--------------------------------------------------------------------------------
tnAmplifierMeshCardConfigAttributeTotal OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Total number of attributes in
tnAmplifierMeshCardConfigTable."
::= { tnAmplifierCardConfig 3 }
--------------------------------------------------------------------------------
-- Mesh Amplifier Card Config Table
--------------------------------------------------------------------------------
tnAmplifierMeshCardConfigTable OBJECT-TYPE
SYNTAX SEQUENCE OF TnAmplifierMeshCardConfigEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The provisioned parameters on an amplifier
module in a mesh card."
::= { tnAmplifierCardConfig 4 }
tnAmplifierMeshCardConfigEntry OBJECT-TYPE
SYNTAX TnAmplifierMeshCardConfigEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "."
INDEX { tnShelfIndex,
tnSlotIndex }
::= { tnAmplifierMeshCardConfigTable 1 }
TnAmplifierMeshCardConfigEntry ::= SEQUENCE {
tnAmplifierMeshCardPowerGain Unsigned32,
tnAmplifierMeshCardPowerGainMin Unsigned32,
tnAmplifierMeshCardPowerGainMax Unsigned32,
tnAmplifierMeshCardTargetTilt Integer32,
tnAmplifierMeshCardVoaSet Unsigned32,
tnAmplifierMeshCardCommonEgressPower Integer32
}
tnAmplifierMeshCardPowerGain OBJECT-TYPE
SYNTAX Unsigned32 (700..2400)
UNITS "mB"
MAX-ACCESS read-create
STATUS current
DESCRIPTION "The following description applies to the output
port of the amplifier module in the mesh card:
Current configurable range:
MESH4: 700 to 2400."
DEFVAL { 700 }
::= { tnAmplifierMeshCardConfigEntry 1 }
tnAmplifierMeshCardPowerGainMin OBJECT-TYPE
SYNTAX Unsigned32 (700..2400)
UNITS "mB"
MAX-ACCESS read-create
STATUS current
DESCRIPTION "The following description applies to the output
port of the amplifier module in the mesh card:
This value is used by power management.
Current configurable range:
MESH4: 700 to 2400."
DEFVAL { 700 }
::= { tnAmplifierMeshCardConfigEntry 2 }
tnAmplifierMeshCardPowerGainMax OBJECT-TYPE
SYNTAX Unsigned32 (700..2400)
UNITS "mB"
MAX-ACCESS read-create
STATUS current
DESCRIPTION "The following description applies to the output
port of the amplifier module in the mesh card:
This value is used by power management.
Current configurable range:
MESH4: 700 to 2400."
DEFVAL { 2400 }
::= { tnAmplifierMeshCardConfigEntry 3 }
tnAmplifierMeshCardTargetTilt OBJECT-TYPE
SYNTAX Integer32 (-400..400)
UNITS "mB"
MAX-ACCESS read-create
STATUS current
DESCRIPTION "The following description applies to the output
port of the amplifier module in the mesh card:
EPT - Tilt.
Current configurable range:
MESH4: -400 to 400."
DEFVAL { 0 }
::= { tnAmplifierMeshCardConfigEntry 4 }
tnAmplifierMeshCardVoaSet OBJECT-TYPE
SYNTAX Unsigned32 (0..1800)
UNITS "mBm"
MAX-ACCESS read-create
STATUS current
DESCRIPTION "The following description applies to the output
port of the amplifier module in the mesh card:
Current configurable range:
MESH4: 0 to 1800."
DEFVAL { 0 }
::= { tnAmplifierMeshCardConfigEntry 5 }
tnAmplifierMeshCardCommonEgressPower OBJECT-TYPE
SYNTAX Integer32 (-1000..1000)
UNITS "mBm"
MAX-ACCESS read-create
STATUS current
DESCRIPTION "Common Egress Power. This is the per channel
default egress power
Current configurable range:
MESH4: -1000 to 1000."
DEFVAL { 100 }
::= { tnAmplifierMeshCardConfigEntry 6 }
--------------------------------------------------------------------------------
-- Conformance Group Definitions
--------------------------------------------------------------------------------
--------------------------------------------------------------------------------
-- Conformance Amplifier Port Config Group Definitions
--------------------------------------------------------------------------------
tnAmplifierPortConfigScalarsGroup OBJECT-GROUP
OBJECTS {
tnAmplifierPortConfigAttributeTotal
}
STATUS current
DESCRIPTION "."
::= { tnAmplifierPortConfigGroups 1 }
tnAmplifierPortConfigGroup OBJECT-GROUP
OBJECTS {
tnAmplifierPortPowerGain,
tnAmplifierPortPowerGainMin,
tnAmplifierPortPowerGainMax,
tnAmplifierPortPowerGainBackoff,
tnAmplifierPortEnable,
tnAmplifierPortAutoReEnableMode,
-- obsolete
-- tnAmplifierPortAutoReEnableBackoffTime,
tnAmplifierPortPowerSpanRepairMargin,
tnAmplifierPortPowerDeltaMax,
tnAmplifierPortTargetTilt,
tnAmplifierPortFunction,
tnAmplifierPortAprDisable,
tnAmplifierPortSRSTiltACoeffDCM,
tnAmplifierPortMaxFlatGainOffset,
tnAmplifierPortGainTilt,
tnAmplifierPortAprHoldOffTime,
tnAmplifierPortLosMode,
tnAmplifierPortSignalFailThreshold,
tnAmplifierPortSignalDegradeThreshold,
tnAmplifierPortVoaSet,
tnAmplifierPortGainRange,
tnAmplifierPortAprMode,
tnAmplifierPortOperatingMode,
tnAmplifierPortSignalPowerTarget,
tnAmplifierPortPowerGainL,
tnAmplifierPortPowerGainMinL,
tnAmplifierPortPowerGainMaxL,
tnAmplifierPortPowerDeltaMaxL,
tnAmplifierPortGainRangeL,
tnAmplifierPortTargetTiltL,
tnAmplifierPortVoaSetL,
tnAmplifierPortGainTiltL,
tnAmplifierPortPowerGainBackoffL,
tnAmplifierPortPowerSpanRepairMarginL,
tnAmplifierPortOperatingModeL,
tnAmplifierPortSignalPowerTargetL,
tnAmplifierPortUserSelectedExteriorDcmPresentIn,
tnAmplifierPortUserSelectedExteriorDcmPresentOut,
tnAmplifierPortBandMode,
tnAmplifierPortLosModeL,
tnAmplifierPortBoosterTargetPowerIn,
tnAmplifierPortAprEDFApulse,
tnAmplifierPortLineDcmConnAddress,
tnAmplifierPortAPREDFAPulseAttempt,
tnAmplifierPortSpanLossTh,
tnAmplifierPortAsellLink,
tnAmplifierPortTargetPowerWidth,
tnAmplifierPortTargetPowerWidthL,
tnAmplifierPortAsellLinkL
}
STATUS current
DESCRIPTION "."
::= { tnAmplifierPortConfigGroups 2 }
tnAmplifierHybridPortConfigScalarsGroup OBJECT-GROUP
OBJECTS {
tnAmplifierHybridPortConfigAttributeTotal
}
STATUS current
DESCRIPTION "."
::= { tnAmplifierPortConfigGroups 3 }
tnAmplifierHybridPortConfigGroup OBJECT-GROUP
OBJECTS {
tnAmplifierHybridPortVoaAttenuation,
tnAmplifierHybridPortInitialMidLoss,
tnAmplifierHybridPortInitialAgcTargetGain,
tnAmplifierHybridPortVoaMinAttenuation,
tnAmplifierHybridPortVoaMaxAttenuation
}
STATUS current
DESCRIPTION "."
::= { tnAmplifierPortConfigGroups 4 }
--------------------------------------------------------------------------------
-- Conformance Amplifier Port Info Group Definitions
--------------------------------------------------------------------------------
tnAmplifierPortInfoScalarsGroup OBJECT-GROUP
OBJECTS {
tnAmplifierPortInfoAttributeTotal
}
STATUS current
DESCRIPTION "."
::= { tnAmplifierPortInfoGroups 1 }
tnAmplifierPortInfoGroup OBJECT-GROUP
OBJECTS {
tnAmplifierPortInternalAmpModuleTemperature,
tnAmplifierPortPowerIn,
tnAmplifierPortPowerOut,
tnAmplifierPortSignalPowerOut,
tnAmplifierPortInputToOutputGain,
tnAmplifierPortDCMInPower,
tnAmplifierPortDCMOutPower,
tnAmplifierPortActualTilt,
tnAmplifierPortWtOcmMonitorPortOut,
tnAmplifierPortOSCTxPowerIn,
tnAmplifierPortOSCTxPowerOut,
tnAmplifierPortTestingActive,
tnAmplifierCommonEgressOutputPower,
tnAmplifierActOutAtten,
tnAmplifierCommonEgressOutputPowerL,
tnAmplifierActOutAttenL,
tnAmplifierPortActualTiltL,
tnAmplifierPortSignalPowerOutL,
tnAmplifierPortInputToOutputGainL,
tnAmplifierPortOSCTxPowerOutL,
tnAmplifierPortPowerInL,
tnAmplifierPortInfoOSCRxPowerIn,
tnAmplifierPortInfoOSCSfpTxPowerOut,
tnAmplifierPortInfoOSCSfpRxPowerIn,
tnAmplifierPortBoosterTargetPowerOut,
tnAmplifierPortPowerOutL,
tnAmplifierPortSpanLoss,
tnAmplifierPortAprEDFApulsePower
}
STATUS current
DESCRIPTION "."
::= { tnAmplifierPortInfoGroups 2 }
tnAmplifierMeshPortInfoScalarsGroup OBJECT-GROUP
OBJECTS {
tnAmplifierMeshPortInfoAttributeTotal
}
STATUS current
DESCRIPTION "."
::= { tnAmplifierPortInfoGroups 3 }
tnAmplifierMeshPortInfoGroup OBJECT-GROUP
OBJECTS {
tnAmplifierMeshPortPowerOut,
tnAmplifierMeshPortSignalPowerOut,
tnAmplifierMeshPortInputToOutputGain
}
STATUS current
DESCRIPTION "."
::= { tnAmplifierPortInfoGroups 4 }
tnAmplifierHybridPortInfoScalarsGroup OBJECT-GROUP
OBJECTS {
tnAmplifierHybridPortInfoAttributeTotal
}
STATUS current
DESCRIPTION "."
::= { tnAmplifierPortInfoGroups 5 }
tnAmplifierHybridPortInfoGroup OBJECT-GROUP
OBJECTS {
tnAmplifierHybridPortInternalAmpModuleTemperature
}
STATUS current
DESCRIPTION "."
::= { tnAmplifierPortInfoGroups 6 }
--------------------------------------------------------------------------------
-- Conformance Amplifier Card Info Group Definitions
--------------------------------------------------------------------------------
tnAmplifierCardInfoScalarsGroup OBJECT-GROUP
OBJECTS {
tnAmplifierCardInfoAttributeTotal
}
STATUS current
DESCRIPTION "."
::= { tnAmplifierCardInfoGroups 1 }
tnAmplifierCardInfoGroup OBJECT-GROUP
OBJECTS {
tnAmplifierCardOAMPump1Temperature,
tnAmplifierCardOAMPump2Temperature,
tnAmplifierCardOAMPump3Temperature,
tnAmplifierCardOAMPump1Bias,
tnAmplifierCardOAMPump2Bias,
tnAmplifierCardOAMPump3Bias,
tnAmplifierCardOptIntSpanLoss,
tnAmplifierCardOAMPump4Temperature,
tnAmplifierCardOAMPump5Temperature,
tnAmplifierCardOAMPump6Temperature,
tnAmplifierCardOAMPump4Bias,
tnAmplifierCardOAMPump5Bias,
tnAmplifierCardOAMPump6Bias,
tnAmplifierCardOAMLPump1Temperature,
tnAmplifierCardOAMLPump2Temperature,
tnAmplifierCardOAMLPump3Temperature,
tnAmplifierCardOAMLPump4Temperature,
tnAmplifierCardOAMLPump1Bias,
tnAmplifierCardOAMLPump2Bias,
tnAmplifierCardOAMLPump3Bias,
tnAmplifierCardOAMLPump4Bias,
tnAmplifierCardOAM1PumpTemperatures,
tnAmplifierCardOAM2PumpTemperatures,
tnAmplifierCardOAM1PumpBiases,
tnAmplifierCardOAM2PumpBiases,
tnAmplifierCardOAM3PumpTemperatures,
tnAmplifierCardOAM3PumpBiases
}
STATUS current
DESCRIPTION "."
::= { tnAmplifierCardInfoGroups 2 }
tnAmplifierMeshCardInfoScalarsGroup OBJECT-GROUP
OBJECTS {
tnAmplifierMeshCardInfoAttributeTotal
}
STATUS current
DESCRIPTION "."
::= { tnAmplifierCardInfoGroups 3 }
tnAmplifierMeshCardInfoGroup OBJECT-GROUP
OBJECTS {
tnAmplifierMeshCardInternalTemperature,
tnAmplifierMeshCardPowerIn,
tnAmplifierMeshCardPowerOut,
tnAmplifierMeshCardSignalPowerOut,
tnAmplifierMeshCardInputToOutputGain,
tnAmplifierMeshCardGainTilt,
tnAmplifierMeshCardActualTilt
}
STATUS current
DESCRIPTION "."
::= { tnAmplifierCardInfoGroups 4 }
tnAmplifierHybridCardInfoScalarsGroup OBJECT-GROUP
OBJECTS {
tnAmplifierHybridCardInfoAttributeTotal
}
STATUS current
DESCRIPTION "."
::= { tnAmplifierCardInfoGroups 5 }
tnAmplifierHybridCardInfoGroup OBJECT-GROUP
OBJECTS {
tnAmplifierHybridCardOAMPump1Temperature,
tnAmplifierHybridCardOAMPump2Temperature,
tnAmplifierHybridCardOAMPump1Bias,
tnAmplifierHybridCardOAMPump2Bias,
tnAmplifierHybridCardOAMPump3Temperature,
tnAmplifierHybridCardOAMPump4Temperature,
tnAmplifierHybridCardOAMPump3Bias,
tnAmplifierHybridCardOAMPump4Bias
}
STATUS current
DESCRIPTION "."
::= { tnAmplifierCardInfoGroups 6 }
--------------------------------------------------------------------------------
-- Conformance Amplifier Card Config Group Definitions
--------------------------------------------------------------------------------
tnAmplifierCardConfigScalarsGroup OBJECT-GROUP
OBJECTS {
tnAmplifierCardConfigAttributeTotal
}
STATUS current
DESCRIPTION "."
::= { tnAmplifierCardConfigGroups 1 }
tnAmplifierCardConfigGroup OBJECT-GROUP
OBJECTS {
tnAmplifierCardOptIntDetection,
tnAmplifierCardOptIntBaseline,
tnAmplifierCardOptIntLossThreshold,
tnAmplifierCardOptIntPollPeriod,
tnAmplifierCardOptIntClearAlarm,
tnAmplifierCardAsonAddDropPlannedForOps
}
STATUS current
DESCRIPTION "."
::= { tnAmplifierCardConfigGroups 2 }
tnAmplifierMeshCardConfigScalarsGroup OBJECT-GROUP
OBJECTS {
tnAmplifierMeshCardConfigAttributeTotal
}
STATUS current
DESCRIPTION "."
::= { tnAmplifierCardConfigGroups 3 }
tnAmplifierMeshCardConfigGroup OBJECT-GROUP
OBJECTS {
tnAmplifierMeshCardPowerGain,
tnAmplifierMeshCardPowerGainMin,
tnAmplifierMeshCardPowerGainMax,
tnAmplifierMeshCardTargetTilt,
tnAmplifierMeshCardVoaSet,
tnAmplifierMeshCardCommonEgressPower
}
STATUS current
DESCRIPTION "."
::= { tnAmplifierCardConfigGroups 4 }
--------------------------------------------------------------------------------
-- Compliance Statements (mandatory)
--------------------------------------------------------------------------------
--------------------------------------------------------------------------------
-- Compliance Port Config Statements (mandatory)
--------------------------------------------------------------------------------
tnAmplifierPortConfigCompliance MODULE-COMPLIANCE
STATUS current
DESCRIPTION "."
MODULE
MANDATORY-GROUPS {
tnAmplifierPortConfigScalarsGroup,
tnAmplifierPortConfigGroup,
tnAmplifierHybridPortConfigScalarsGroup,
tnAmplifierHybridPortConfigGroup
}
::= { tnAmplifierPortConfigCompliances 1 }
--------------------------------------------------------------------------------
-- Compliance Port Info Statements (mandatory)
--------------------------------------------------------------------------------
tnAmplifierPortInfoCompliance MODULE-COMPLIANCE
STATUS current
DESCRIPTION "."
MODULE
MANDATORY-GROUPS {
tnAmplifierPortInfoScalarsGroup,
tnAmplifierPortInfoGroup,
tnAmplifierMeshPortInfoScalarsGroup,
tnAmplifierMeshPortInfoGroup,
tnAmplifierHybridPortInfoScalarsGroup,
tnAmplifierHybridPortInfoGroup
}
::= { tnAmplifierPortInfoCompliances 1 }
--------------------------------------------------------------------------------
-- Compliance Card Info Statements (mandatory)
--------------------------------------------------------------------------------
tnAmplifierCardInfoCompliance MODULE-COMPLIANCE
STATUS current
DESCRIPTION "."
MODULE
MANDATORY-GROUPS {
tnAmplifierCardInfoScalarsGroup,
tnAmplifierCardInfoGroup,
tnAmplifierMeshCardInfoScalarsGroup,
tnAmplifierMeshCardInfoGroup,
tnAmplifierHybridCardInfoScalarsGroup,
tnAmplifierHybridCardInfoGroup
}
::= { tnAmplifierCardInfoCompliances 1 }
--------------------------------------------------------------------------------
-- Compliance Card Config Statements (mandatory)
--------------------------------------------------------------------------------
tnAmplifierCardConfigCompliance MODULE-COMPLIANCE
STATUS current
DESCRIPTION "."
MODULE
MANDATORY-GROUPS {
tnAmplifierCardConfigScalarsGroup,
tnAmplifierCardConfigGroup,
tnAmplifierMeshCardConfigScalarsGroup,
tnAmplifierMeshCardConfigGroup
}
::= { tnAmplifierCardConfigCompliances 1 }
END -- DEFINITION OF TROPIC-AMPLIFIER-MIB