Observium_CE/mibs/nokia/TN-IEEE8021-CFM-MIB

3012 lines
113 KiB
Plaintext

TN-IEEE8021-CFM-MIB DEFINITIONS ::= BEGIN
-- (c) Copyright 2021 Nokia Networks. All rights reserved.
-- This software is the confidential and proprietary property of
-- Nokia and may only be used in accordance with the terms of the
-- license agreement provided with this software.
IMPORTS
MODULE-IDENTITY, Unsigned32, OBJECT-TYPE,
NOTIFICATION-TYPE, Integer32, Counter32,
Gauge32 FROM SNMPv2-SMI
TEXTUAL-CONVENTION,
MacAddress, TruthValue FROM SNMPv2-TC
InterfaceIndex FROM IF-MIB
dot1agCfmMdIndex, dot1agCfmMaIndex,
dot1agCfmMepIdentifier,
Dot1agCfmMDLevel, Dot1agCfmMpDirection,
Dot1agCfmMepIdOrZero, dot1agCfmMepEntry,
Dot1agCfmMepId,
dot1agCfmMepTransmitLbmDestMacAddress,
dot1agCfmMepTransmitLtmSeqNumber,
Dot1agCfmCcmInterval,
dot1agCfmMaNetEntry,
dot1agCfmMaMepListEntry FROM IEEE8021-CFM-MIB
tnSRMIBModules, tnSRObjs,
tnSRNotifyPrefix FROM TROPIC-GLOBAL-REG
SdpId FROM TN-SERV-MIB
tnSysSwitchId FROM TROPIC-SYSTEM-MIB
TmnxServId, TmnxEnabledDisabled, TNamedItem FROM TN-TC-MIB;
tnIEEE8021CfmMIBModule MODULE-IDENTITY
LAST-UPDATED "202109171200Z"
ORGANIZATION "Nokia"
CONTACT-INFO
"Nokia 7x50 Support
Web: http://www.nokia.com/comps/pages/carrier_support.jhtml"
DESCRIPTION
"This document is the SNMP MIB module to manage and provision dot1ag
Connectivity Fault Management module functionality for the Nokia 7x50
products. This includes extensions to the IEEE8021-CFM MIB.
This SNMP MIB module (Specification) embodies Nokia's
proprietary intellectual property. Nokia retains
all title and ownership in the Specification, including any
revisions.
Nokia grants all interested parties a non-exclusive
license to use and distribute an unmodified copy of this
Specification in connection with management of Nokia
products, and without fee, provided this copyright notice and
license appear on all copies.
This Specification is supplied 'as is', and Nokia
makes no warranty, either express or implied, as to the use,
operation, condition, or performance of the Specification."
--
-- Revision History
--
REVISION "202109171200Z"
DESCRIPTION "Added the following to tnDot1agCfmMepOndemandLmTestRsltTable:
tnDot1agCfmMepOndemandLmRemoteMacAddr."
REVISION "202106041200Z"
DESCRIPTION "Added the following to tnDot1agCfmMepOndemandLmTestTable:
tnDot1agCfmMepOndemandLmTimeout."
REVISION "202005221200Z"
DESCRIPTION "Added the following to tnDot1agCfmStackMPType:
ethRing(3)
to
facInterface(5)."
REVISION "201911221200Z"
DESCRIPTION "1) Changed SYNTAX of the following from Unsigned32(1..90) to
Unsigned32(1..5000):
tnDot1agCfmMepSlmTWInterval.
2) Added the following to tnDot1agCfmMepSlmTWIntrvlUnits:
decimilliseconds(3)."
REVISION "201908031200Z"
DESCRIPTION "Added the following to tnDot1agCfmMepTable:
tnDot1agCfmMepAlmProfName."
REVISION "201905031200Z"
DESCRIPTION "Added the following to tnDot1agCfmMepDelayRsltTable:
tnDot1agCfmMepDelayNearEndTestDelay
tnDot1agCfmMepDelayNearEndVariation
tnDot1agCfmMepDelayFarEndTestDelay
tnDot1agCfmMepDelayFarEndVariation."
REVISION "201903291200Z"
DESCRIPTION "Added the following to tnDot1agCfmMepTable:
tnDot1agCfmMepOWDTDataSize."
REVISION "201710061200Z"
DESCRIPTION "1) Added the following to tnDot1agCfmMaMepListTable:
tnDot1agCfmMaMepListSapSubType.
2) Fixed MIB compile issues."
REVISION "201505081200Z"
DESCRIPTION "1) Added the following to tnDot1agCfmMepTable:
tnDot1agCfmMepType
2) Added the following to tnDot1agCfmMepTable:
tnDot1agCfmMepFaultPropagation"
REVISION "201409181200Z"
DESCRIPTION "Added the following to tnDot1agCfmMepTable:
tnDot1agCfmMepTransmitLbmDataTlvSize."
REVISION "201407241200Z"
DESCRIPTION "Changed range for tnDot1agCfmMepSlmTWDataSize to 9558 from 1500."
REVISION "201402100000Z"
DESCRIPTION "Added the following to tnDot1agCfmMepTable:
tnDot1agCfmMepTWDTDataSize."
REVISION "201308220000Z"
DESCRIPTION "1) Added the following tables:
tnDot1agCfmMaNetTable
tnDot1agCfmMaMepListTable
tnDot1agCfmComponentLimitTable.
2) Added the following to tnDot1agCfmMepSlmTWTestTable:
tnDot1agCfmMepSlmTWIntrvlUnits.
3) Updated upper range of tnDot1agCfmMepSlmTWInterval
from 10 to 90.
4) Updated upper range of tnDot1agCfmMepSlmTWSendCount
from 100 to 1000."
REVISION "201212130000Z"
DESCRIPTION "1) Added the following to tnDot1agCfmMepTable:
tnDot1agCfmMepMcLagInactive.
2) Added the following table:
tnDot1agCfmMcLagConfigTable."
REVISION "201212050000Z"
DESCRIPTION "Commented out unsupported MIB tables and
attributes for 1830."
REVISION "201209091200Z"
DESCRIPTION "1) Added the following to tnDot1agCfmMepSlmTWTestTable:
tnDot1agCfmMepSlmTWIntervalRedef.
2) Added the following tables:
tnDot1agCfmMepOndemandLmTestTable
tnDot1agCfmMepOndemandLmTestRsltTable
tnDot1agCfmMepOWDelayRsltExtTable.
3) Added the following notification:
tnDot1agCfmMepOndemandLmTestComplete."
REVISION "201203291200Z"
DESCRIPTION "Added tnDot1agCfmMepCsfTable."
REVISION "200902280000Z"
DESCRIPTION "Rev 7.0 28 Feb 2009 00:00
7.0 release of the TIMETRA-IEEE8021-CFM-MIB."
REVISION "200801010000Z"
DESCRIPTION "Rev 1.0 01 Jan 2008 00:00
Initial version of the TIMETRA-IEEE8021-CFM-MIB."
::= { tnSRMIBModules 52 }
--%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%
--
-- Nokia 7x50 product series IEEE8021-CFM extensions
--
tnDot1agMIBObjs OBJECT IDENTIFIER ::= { tnSRObjs 52 }
tnDot1agNotificationsPrefix OBJECT IDENTIFIER ::= { tnSRNotifyPrefix 52 }
tnDot1agNotifications OBJECT IDENTIFIER ::= { tnDot1agNotificationsPrefix 0 }
-- tnDot1agMIBConformance OBJECT IDENTIFIER ::= { tnSRConfs 52 }
-- Groups in the Nokia CFM MIB Module
tnDot1agCfmStack OBJECT IDENTIFIER ::= { tnDot1agMIBObjs 1 }
tnDot1agCfmGlobalObjs OBJECT IDENTIFIER ::= { tnDot1agMIBObjs 2 }
tnDot1agCfmMa OBJECT IDENTIFIER ::= { tnDot1agMIBObjs 6 }
tnDot1agCfmMep OBJECT IDENTIFIER ::= { tnDot1agMIBObjs 7 }
-- tnDot1agCfmMip OBJECT IDENTIFIER ::= { tnDot1agMIBObjs 8 }
-- tnDot1agCfmNotificationObjs OBJECT IDENTIFIER ::= { tnDot1agMIBObjs 9 }
NokiaPmonUnitType ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION "Statistics unit type for proactive and on-demand OAM PM."
SYNTAX INTEGER {
microseconds(1),
hundred-nano-seconds(2),
nano-seconds(3)
}
--
--
-- Nokia 7x50 product series dot1ag CFM SDP-Bind Stack Table
--
-- This table is a mirror of the dot1agCfmStackTable in IEEE8021-CFM-MIB.
--
-- The indexes of this table differ from that of the dot1agCfmStackTable
-- by the replacement of the dot1agCfmStackIfIndex and
-- dot1agCfmStackVlanIdOrNone indexes with that of the
-- tnDot1agCfmSdpBindStackSdpid and tnDot1agCfmSdpBindStackVcId indexes.
-- The CFM Sdp-Bind Stack Table
-- tnDot1agCfmSdpBindStackTable OBJECT-TYPE
-- SYNTAX SEQUENCE OF TnDot1agCfmSdpBindStackEntry
-- MAX-ACCESS not-accessible
-- STATUS current
-- DESCRIPTION
-- "There is one CFM Sdp-Bind Stack table per bridge. It permits
-- the retrieval of information about the Maintenance Points
-- configured on any given Sdp bindings."
-- REFERENCE
-- "802.1ag clauses 12.14.2"
-- ::= { tnDot1agCfmStack 1 }
--
-- tnDot1agCfmSdpBindStackEntry OBJECT-TYPE
-- SYNTAX TnDot1agCfmSdpBindStackEntry
-- MAX-ACCESS not-accessible
-- STATUS current
-- DESCRIPTION
-- "A conceptual row in the tnDot1agCfmSdpBindStackTable. This row behaves
-- exactly like the dot1agCfmStackEntry row."
-- INDEX { tnDot1agCfmSdpBindStackSdpId,
-- tnDot1agCfmSdpBindStackVcId,
-- tnDot1agCfmSdpBindStackMdLevel,
-- tnDot1agCfmSdpBindStackDirection
-- }
-- ::= { tnDot1agCfmSdpBindStackTable 1 }
--
-- TnDot1agCfmSdpBindStackEntry ::= SEQUENCE {
-- tnDot1agCfmSdpBindStackSdpId SdpId,
-- tnDot1agCfmSdpBindStackVcId Unsigned32,
-- tnDot1agCfmSdpBindStackMdLevel Dot1agCfmMDLevel,
-- tnDot1agCfmSdpBindStackDirection Dot1agCfmMpDirection,
-- tnDot1agCfmSdpBindStackMdIndex Unsigned32,
-- tnDot1agCfmSdpBindStackMaIndex Unsigned32,
-- tnDot1agCfmSdpBindStackMepId Dot1agCfmMepIdOrZero,
-- tnDot1agCfmSdpBindStackMacAddress MacAddress
-- }
--
-- tnDot1agCfmSdpBindStackSdpId OBJECT-TYPE
-- SYNTAX SdpId
-- MAX-ACCESS not-accessible
-- STATUS current
-- DESCRIPTION
-- "The value of tnDot1agCfmSdpBindStackSdpId specifies the
-- Bridge Port or aggregated port on which MEPs or MHFs
-- might be configured."
-- REFERENCE
-- "802.1ag clause 12.14.2.1.2:a"
-- ::= { tnDot1agCfmSdpBindStackEntry 1 }
--
-- tnDot1agCfmSdpBindStackVcId OBJECT-TYPE
-- SYNTAX Unsigned32
-- MAX-ACCESS not-accessible
-- STATUS current
-- DESCRIPTION
-- "The value of tnDot1agCfmSdpBindStackVcId specifies, along with
-- tnDot1agCfmSdpBindStackSdpId, the SDP Binding for the bridge."
-- REFERENCE
-- "802.1ag clause 12.14.2.1.2:d"
-- ::= { tnDot1agCfmSdpBindStackEntry 2 }
--
-- tnDot1agCfmSdpBindStackMdLevel OBJECT-TYPE
-- SYNTAX Dot1agCfmMDLevel
-- MAX-ACCESS not-accessible
-- STATUS current
-- DESCRIPTION
-- "The value of tnDot1agCfmSdpBindStackMdLevel specifies the MD Level of
-- the Maintenance Point."
-- REFERENCE
-- "802.1ag clause 12.14.2.1.2:b"
-- ::= { tnDot1agCfmSdpBindStackEntry 3 }
--
-- tnDot1agCfmSdpBindStackDirection OBJECT-TYPE
-- SYNTAX Dot1agCfmMpDirection
-- MAX-ACCESS not-accessible
-- STATUS current
-- DESCRIPTION
-- "The value of tnDot1agCfmSdpBindStackDirection specifies the
-- Direction in which the MP faces on the Bridge Port"
-- REFERENCE
-- "802.1ag clause 12.14.2.1.2:c"
-- ::= { tnDot1agCfmSdpBindStackEntry 4 }
--
-- tnDot1agCfmSdpBindStackMdIndex OBJECT-TYPE
-- SYNTAX Unsigned32
-- MAX-ACCESS read-only
-- STATUS current
-- DESCRIPTION
-- "The value of tnDot1agCfmSdpBindStackMdIndex indicates the index
-- of the Maintenance Domain in the dot1agCfmMdTable to which the
-- MP is associated, or 0, if none."
-- REFERENCE
-- "802.1ag clause 12.14.2.1.3:b"
-- ::= { tnDot1agCfmSdpBindStackEntry 5 }
--
-- tnDot1agCfmSdpBindStackMaIndex OBJECT-TYPE
-- SYNTAX Unsigned32
-- MAX-ACCESS read-only
-- STATUS current
-- DESCRIPTION
-- "The value of tnDot1agCfmSdpBindStackMaIndex indicates the index
-- of the MA in the dot1agCfmMaNetTable and dot1agCfmMaCompTable
-- to which the MP is associated, or 0, if none."
-- REFERENCE
-- "802.1ag clause 12.14.2.1.3:c"
-- ::= { tnDot1agCfmSdpBindStackEntry 6 }
--
-- tnDot1agCfmSdpBindStackMepId OBJECT-TYPE
-- SYNTAX Dot1agCfmMepIdOrZero
-- MAX-ACCESS read-only
-- STATUS current
-- DESCRIPTION
-- "The value of tnDot1agCfmSdpBindStackMepId indicates if an MEP
-- is configured, the MEPID, else 0"
-- REFERENCE
-- "802.1ag clause 12.14.2.1.3:d"
-- ::= { tnDot1agCfmSdpBindStackEntry 7 }
--
-- tnDot1agCfmSdpBindStackMacAddress OBJECT-TYPE
-- SYNTAX MacAddress
-- MAX-ACCESS read-only
-- STATUS current
-- DESCRIPTION
-- "The value of tnDot1agCfmSdpBindStackMacAddress indicates
-- the MAC address of the MP."
-- REFERENCE
-- "802.1ag clause 12.14.2.1.3:e"
-- ::= { tnDot1agCfmSdpBindStackEntry 8 }
-- Nokia 7x50 product series CFM MepEntry table
--
-- This table is an augmentation of the dot1agCfmMepTable in IEEE8021-CFM-MIB.
--
-- Use of AUGMENTS clause implies a one-to-one dependent relationship between
-- the base table, dot1agCfmMepTable, and the augmenting table,
-- tnDot1agCfmMepTable, with additional columns. Creation (or deletion) of a row
-- in the dot1agCfmMepTable results in the same fate for the row in the
-- tnDot1agCfmMepTable.
-- ******************************************************************
-- The MEP Table
-- ******************************************************************
tnDot1agCfmMepTable OBJECT-TYPE
SYNTAX SEQUENCE OF TnDot1agCfmMepEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table augments the Maintenance Association End Point (MEP) table
of the IEEE8021-CFM-MIB."
::= { tnDot1agCfmMep 1 }
tnDot1agCfmMepEntry OBJECT-TYPE
SYNTAX TnDot1agCfmMepEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A conceptual row in the tnDot1agCfmMepTable. This row exists only
if the association dot1agCfmMepEntry is active."
AUGMENTS { dot1agCfmMepEntry }
::= { tnDot1agCfmMepTable 1 }
TnDot1agCfmMepEntry ::= SEQUENCE {
tnDot1agCfmMepSdpId SdpId,
tnDot1agCfmMepVcId Unsigned32,
tnDot1agCfmMepMacAddress MacAddress,
tnDot1agCfmMepAisEnable TruthValue,
tnDot1agCfmMepAisMegLevel BITS,
tnDot1agCfmMepAisPriority Unsigned32,
tnDot1agCfmMepAisInterval Unsigned32,
tnDot1agCfmMepEthRxAisInterval Unsigned32,
tnDot1agCfmMepEthRxAis TruthValue,
tnDot1agCfmMepEthAisTxCount Counter32,
tnDot1agCfmMepEthTestEnable TruthValue,
tnDot1agCfmMepEthTestPattern INTEGER,
tnDot1agCfmMepEthTestMacAddr MacAddress,
tnDot1agCfmMepEthTestDataLen Unsigned32,
tnDot1agCfmMepEthTestPriority Unsigned32,
tnDot1agCfmMepOWDTMacAddress MacAddress,
tnDot1agCfmMepOWDTPriority Unsigned32,
tnDot1agCfmMepTWDTMacAddress MacAddress,
tnDot1agCfmMepTWDTPriority Unsigned32,
tnDot1agCfmMepSvcId TmnxServId,
tnDot1agCfmMepControlMep TruthValue,
tnDot1agCfmMepEthTestThreshold Unsigned32,
tnDot1agCfmMepOWDTThreshold Unsigned32,
tnDot1agCfmMepMcLagInactive INTEGER,
tnDot1agCfmMepTWDTDataSize Unsigned32,
tnDot1agCfmMepTransmitLbmDataTlvSize Unsigned32,
tnDot1agCfmMepType INTEGER,
tnDot1agCfmMepFaultPropagation INTEGER,
tnDot1agCfmMepOWDTDataSize Unsigned32,
tnDot1agCfmMepAlmProfName OCTET STRING
}
tnDot1agCfmMepSdpId OBJECT-TYPE
SYNTAX SdpId
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The value of tnDot1agCfmMepSdpId specifies, along with the
tnDot1agCfmMepVcId, the SDP-Binding within a bridge port,
to which the MEP is attached.
This object is applicable to SDP-Bindings only, and MUST be set
to the null ID (0) when dot1agCfmMepIfIndex or
dot1agCfmMepPrimaryVid, is non-zero. When this object is
applicable (non-zero), the dot1agCfmMepIfIndex and
dot1agCfmMepPrimaryVid MUST be set to zero (0)."
REFERENCE
"802.1ag clause 12.14.2.1.2:a"
::= { tnDot1agCfmMepEntry 1 }
tnDot1agCfmMepVcId OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The value of tnDot1agCfmMepVcId specifies, along with
tnDot1agCfmMepSdpId, the SDP Binding for the bridge.
tnDot1agCfmMepVcId is applicable to SDP-Bindings only, and MUST
be set to zero (0) when dot1agCfmMepIfIndex or
dot1agCfmMepPrimaryVid is non-zero. When this object is
applicable (non-zero), the dot1agCfmMepIfIndex and
dot1agCfmMepPrimaryVid MUST be set to zero (0)."
REFERENCE
"802.1ag clause 12.14.2.1.2:d"
::= { tnDot1agCfmMepEntry 2 }
tnDot1agCfmMepMacAddress OBJECT-TYPE
SYNTAX MacAddress
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The value of tnDot1agCfmMepMacAddress specifies the mac-address
that is assigned to dot1agCfmMepMacAddress."
REFERENCE
"802.1ag clause 12.14.7.1.3:i and 19.4"
::= { tnDot1agCfmMepEntry 3 }
tnDot1agCfmMepAisEnable OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The value of tnDot1agCfmMepAisEnable specifies whether AIS
frames are generated from the Maintenance Entity Group (MEG)."
DEFVAL { false }
::= { tnDot1agCfmMepEntry 4 }
tnDot1agCfmMepAisMegLevel OBJECT-TYPE
SYNTAX BITS {
level1 (0),
level2 (1),
level3 (2),
level4 (3),
level5 (4),
level6 (5),
level7 (6)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The value of tnDot1agCfmMepAisMegLevel specifies the levels
that should be notified to suppress alarms resulting from defect
conditions detected by the MEP."
DEFVAL { { } }
::= { tnDot1agCfmMepEntry 5 }
tnDot1agCfmMepAisPriority OBJECT-TYPE
SYNTAX Unsigned32 (0..7)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The value of tnDot1agCfmMepAisPriority specifies at what priority
the AIS frames should be transmitted."
DEFVAL { 7 }
::= { tnDot1agCfmMepEntry 6 }
tnDot1agCfmMepAisInterval OBJECT-TYPE
SYNTAX Unsigned32 (1 | 60)
UNITS "seconds"
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The value of tnDot1agCfmMepAisInterval specifies at what intervals
to transmit AIS frames."
DEFVAL { 1 }
::= { tnDot1agCfmMepEntry 7 }
tnDot1agCfmMepEthRxAisInterval OBJECT-TYPE
SYNTAX Unsigned32 (1 | 60)
UNITS "seconds"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of tnDot1agCfmMepEthRxAisInterval indicates the AIS Interval
received in the last AIS Frame."
DEFVAL { 1 }
::= { tnDot1agCfmMepEntry 8 }
tnDot1agCfmMepEthRxAis OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of tnDot1agCfmMepEthRxAis indicates the MEP is receiving
AIS test frames from one or more of its sub-layer MEPs."
DEFVAL { false }
::= { tnDot1agCfmMepEntry 9 }
tnDot1agCfmMepEthAisTxCount OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of tnDot1agCfmMepEthAisTxCount indicates number of
AIS frames transmitted on the MEP."
::= { tnDot1agCfmMepEntry 10 }
tnDot1agCfmMepEthTestEnable OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The value of tnDot1agCfmMepEthTestEnable specifies whether
ethernet test frames are to be generated on transmission or
processed on reception. If this object is set to 'false',
then tnDot1agCfmMepEthTestPattern is undefined.
When this object is set to 'true', tnDot1agCfmMepEthTestPattern
is reset to its default value, unless tnDot1agCfmMepEthTestPattern
is set to a specific value in the same SNMP PDU."
DEFVAL { false }
::= { tnDot1agCfmMepEntry 11 }
tnDot1agCfmMepEthTestPattern OBJECT-TYPE
SYNTAX INTEGER {
allZerosNoCrc (0),
allZerosCrc (1),
prbsNoCrc (2),
prbsCrc (3),
allOnesNoCrc (4),
allOnesCrc (5)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The value of tnDot1agCfmMepEthTestPattern specifies the data-content
of the AIS test frames. 'allZerosNoCrc (0)' and 'allZerosCrc (1)'
specifies the data content as all zero values (without and with CRC
calculations respectively). 'prbsNoCrc (3) and 'prbsCrc (4) specifies
the data content as pseudo random bit sequence (without and with CRC
calculations respectively). 'allOnesNoCrc (4)' and 'allOnesCrc (5)',
specifies the data content as all ones (without and with CRC
calculations respectively).
This object is only applicable if tnDot1agCfmMepEthTestEnable is set
to 'true'."
DEFVAL { allZerosNoCrc }
::= { tnDot1agCfmMepEntry 12 }
tnDot1agCfmMepEthTestMacAddr OBJECT-TYPE
SYNTAX MacAddress
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The value of tnDot1agCfmMepEthTestMacAddr specifies the MAC address
of the target to whom the Eth-test frames are sent.
Setting this object will trigger the test frame to be sent. Once the test
is complete, the object will revert to the default value, indicating that
another test is possible."
DEFVAL { '000000000000'H }
::= { tnDot1agCfmMepEntry 13 }
tnDot1agCfmMepEthTestDataLen OBJECT-TYPE
SYNTAX Unsigned32 (64..1500)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The value of tnDot1agCfmMepEthTestDataLen specifies the length of the data
sent in an Eth-test frame. The contents of the data is specified by the
tnDot1agCfmMepEthTestPattern object."
DEFVAL { 64 }
::= { tnDot1agCfmMepEntry 14 }
tnDot1agCfmMepEthTestPriority OBJECT-TYPE
SYNTAX Unsigned32 (0..7)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The value of tnDot1agCfmMepEthTestPriority specifies the priority used
in generating Eth-Test frames."
DEFVAL { 7 }
::= { tnDot1agCfmMepEntry 15 }
tnDot1agCfmMepOWDTMacAddress OBJECT-TYPE
SYNTAX MacAddress
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The value of tnDot1agCfmMepOWDTMacAddress specifies the MAC address used
as a target for the One-Way-Delay Test (OWDT).
Setting this object will trigger a One-Way-Delay test to the specified
MAC address.
Upon completion of the test, the MacAddress will revert to it's
default value, indicating that another test is possible."
DEFVAL { '000000000000'H }
::= { tnDot1agCfmMepEntry 16 }
tnDot1agCfmMepOWDTPriority OBJECT-TYPE
SYNTAX Unsigned32 (0..7)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The value of tnDot1agCfmMepOWDTPriority specifies the priority used in
the generated test frame for the One-Way-Delay test."
DEFVAL { 7 }
::= { tnDot1agCfmMepEntry 17 }
tnDot1agCfmMepTWDTMacAddress OBJECT-TYPE
SYNTAX MacAddress
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The value of tnDot1agCfmMepTWDTMacAddress specifies the MAC address used
as a target for the Two-Way-Delay Test (TWDT).
Setting this object will trigger a Two-Way-Delay test to the specified
MAC address.
Upon completion of the test, the MacAddress will revert to it's
default value, indicating that another test is possible."
DEFVAL { '000000000000'H }
::= { tnDot1agCfmMepEntry 18 }
tnDot1agCfmMepTWDTPriority OBJECT-TYPE
SYNTAX Unsigned32 (0..7)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The value of tnDot1agCfmMepTWDTPriority specifies the priority used in
the generated test frame for the Two-Way-Delay test."
DEFVAL { 7 }
::= { tnDot1agCfmMepEntry 19 }
tnDot1agCfmMepSvcId OBJECT-TYPE
SYNTAX TmnxServId
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The value of tnDot1agCfmMepSvcId specifies the service that the virtual
MEP is being created in.
tnDot1agCfmMepSvcId is applicable to virtual MEPs only, and MUST
be set to zero (0) when dot1agCfmMepIfIndex, dot1agCfmMepPrimaryVid,
tnDot1agCfmMepSdpId, or tnDot1agCfmMepVcId is non-zero. When this
object is applicable (non-zero), the above objects MUST be set to zero (0)."
::= { tnDot1agCfmMepEntry 20 }
tnDot1agCfmMepControlMep OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The value of tnDot1agCfmMepControlMep specifies whether or not the
operational state of the MEP is used by the management entity over which
this MEP is configured."
DEFVAL { false }
::= { tnDot1agCfmMepEntry 21 }
tnDot1agCfmMepEthTestThreshold OBJECT-TYPE
SYNTAX Unsigned32 (0..11840)
UNITS "bit-errors"
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The value of tnDot1agCfmMepEthTestThreshold specifies when a
tnDot1agCfmMepEthTestComplete notification is sent. If
tnDot1agCfmMepEthTestThreshold is set to zero (0), a notification is
sent on the completion of any test for this MEP. Otherwise the
threshold must be exceeded and/or CRC failures must be detected to
send the notification."
DEFVAL { 1 }
::= { tnDot1agCfmMepEntry 22 }
tnDot1agCfmMepOWDTThreshold OBJECT-TYPE
SYNTAX Unsigned32 (0..600)
UNITS "seconds"
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The value of tnDot1agCfmMepOWDTThreshold specifies when a
tnDot1agCfmMepDMTestComplete notification is sent for a one-way-delay
test. If tnDot1agCfmMepOWDTThreshold is set to zero (0), a
notification is sent on the completion of any one-way-delay-test for
this MEP. Otherwise the threshold must be exceeded to send the
notification."
DEFVAL { 3 }
::= { tnDot1agCfmMepEntry 23 }
tnDot1agCfmMepMcLagInactive OBJECT-TYPE
SYNTAX INTEGER {
notApplicable (0),
standby (1),
active (2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of tmnxDot1agCfmMepMcLagInactive indicates whether or not the
MEP is inactive, 'standby (2)', due to the MC-LAG standby state. The
value of tmnxDot1agCfmMcLagStdbyInactive must be set to 'true (1)' for
this object to have meaning and return anything other than
'notApplicable (0)'."
::= { tnDot1agCfmMepEntry 24 }
tnDot1agCfmMepTWDTDataSize OBJECT-TYPE
SYNTAX Unsigned32 (0..9542)
UNITS "bytes"
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The value of tnDot1agCfmMepTWDTDataSize specifies the data size,
in bytes, contained in the padding TLV for the Two-Way delay test.
A value of zero (0) specifies that no padding
TLV is inserted in the packet. Any non-zero value will increase
the packet size by the specified data size plus 3 bytes for the TLV
header."
DEFVAL { 0 }
::= { tnDot1agCfmMepEntry 25 }
tnDot1agCfmMepTransmitLbmDataTlvSize OBJECT-TYPE
SYNTAX Unsigned32 (0..9570)
UNITS "bytes"
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The value of tnDot1agCfmMepTransmitLbmDataTlvSize specifies
the data size, in bytes, contained in the padding TLV
for the LBM test. A value of zero (0) specifies that
no padding TLV is inserted in the packet. Any non-zero value
will increase the packet size by the specified data size."
DEFVAL { 0 }
::= { tnDot1agCfmMepEntry 26 }
tnDot1agCfmMepType OBJECT-TYPE
SYNTAX INTEGER {
default (0),
facilityPort (1),
facilityInterface (2),
sapPrimaryVlan (3)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The value of tmnxDot1agCfmMepType specifies the endpoint type that
this MEP facilitates.
default (0) -- implements a traditional MEP.
facilityPort (1) -- implements a facility port/LAG level MEP.
facilityInterface (2) -- implements a router interface level MEP.
sapPrimaryVlan (3) -- implements a SAP MEP using primary VLAN-ID
from the MA Comp Table. This is only
applicable if the MA primary VLAN ID is
set to a value other than zero (0).
This object must be specified during row creation."
DEFVAL { default }
::= { tnDot1agCfmMepEntry 27 }
tnDot1agCfmMepFaultPropagation OBJECT-TYPE
SYNTAX INTEGER {
disabled (0),
useIfStatusTLV (1),
suspendCCM (2)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The value of tnDot1agCfmMepFaultPropagation specifies what action
should be taken by the MEP if a fault is detected in the service
containing the MEP. It also specifies if the MEP should propagate
a fault that it has detected into the service.
When this object is set to 'disabled (0)', no additional fault
propagation will occur. When this object is set to 'useIfStatusTLV
(1)', the MEP will send an interface status TLV in the next CCM
indicating fault when fault is detected, even if the MEP itself has
not detected a fault. When this object is set to 'suspendCCM (2)',
faults will be propagated by stopping the regular CCM transmissions
entirely. Once the fault is cleared, the regular CCM transmissions
will resume. Additionally, when the value of
tnDot1agCfmMepFaultPropagation is different than 'disabled (0)', a
defect detected by the MEP will be propagated into the service."
DEFVAL { disabled }
::= { tnDot1agCfmMepEntry 28 }
tnDot1agCfmMepOWDTDataSize OBJECT-TYPE
SYNTAX Unsigned32 (0..9542)
UNITS "bytes"
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The value of tnDot1agCfmMepOWDTDataSize specifies the data size,
in bytes, contained in the padding TLV for the one-Way delay test.
A value of zero (0) specifies that no padding TLV is inserted in
the packet. Any non-zero value will increase the packet size by
the specified data size plus 3 bytes for the TLV header."
DEFVAL { 0 }
::= { tnDot1agCfmMepEntry 29 }
tnDot1agCfmMepAlmProfName OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(1..40))
MAX-ACCESS read-create
STATUS current
DESCRIPTION "."
::= { tnDot1agCfmMepEntry 30 }
--
-- This table AUGMENTS the dot1agCfmMaNetTable in IEEE8021-CFM-MIB.
--
-- ******************************************************************
-- The CFM Maintenance Association Table
-- ******************************************************************
tnDot1agCfmMaNetTable OBJECT-TYPE
SYNTAX SEQUENCE OF TDot1agCfmMaNetEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The tnDot1agCfmMaNetTable AUGMENTS the standard MIB table,
dot1agCfmMaNetTable. This table is used to enhance Maintenance
Association functionality for Ethernet Connectivity Fault Management
(ETH-CFM)."
::= { tnDot1agCfmMa 1 }
tnDot1agCfmMaNetEntry OBJECT-TYPE
SYNTAX TDot1agCfmMaNetEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The tnDot1agCfmMaNetEntry consists of the configuration objects
used to enhance the Maintenance Association functionality."
AUGMENTS { dot1agCfmMaNetEntry }
::= { tnDot1agCfmMaNetTable 1 }
TDot1agCfmMaNetEntry ::= SEQUENCE {
tnDot1agCfmMaNetTotalMEPCount Counter32
}
tnDot1agCfmMaNetTotalMEPCount OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of tnDot1agCfmMaNetTotalMEPCount indicates the number of
unique MEPs configured (both local and remote) that are associated with
this MA.
When the number of MEPs exceed the normal MA limits, the MA is
considered to be an extended MA and will use a resource from the
'Extended MA' resource entry in tnDot1agCfmComponentLimitTable."
::= { tnDot1agCfmMaNetEntry 1 }
--
-- The MEP list table augments the standard dot1agCfmMaMepListTable
--
-- ******************************************************************
-- The MEP List Table
-- ******************************************************************
tnDot1agCfmMaMepListTable OBJECT-TYPE
SYNTAX SEQUENCE OF TDot1agCfmMaMepListEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The tnDot1agCfmMaMepListTable extends the functionality of the
dot1agCfmMaMepListTable."
::= { tnDot1agCfmMa 3 }
tnDot1agCfmMaMepListEntry OBJECT-TYPE
SYNTAX TDot1agCfmMaMepListEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The tnDot1agCfmMaMepListEntry augments the standard MIB entry
for the purpose of extending functionality for Dot1ag CFM MEP Lists.
Rows are created and destroyed by the system through the row status
field in dot1agCfmMaMepListEntry."
AUGMENTS { dot1agCfmMaMepListEntry }
::= { tnDot1agCfmMaMepListTable 1 }
TDot1agCfmMaMepListEntry ::= SEQUENCE {
tnDot1agCfmMaMepListMacAddress MacAddress,
tnDot1agCfmMaMepListSapSubType INTEGER
}
tnDot1agCfmMaMepListMacAddress OBJECT-TYPE
SYNTAX MacAddress
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The value of tnDot1agCfmMaMepListMacAddress specifies the target
unicast MAC address used for transmitting CFM packets to the remote
MEPs for the specified MEPID.
Setting a unicast MAC address restricts the number of MEPIDs that can
be configured for an individual MA to a maximum of one (1). Setting the
address back to the default value will remove this restriction and will
result in the regular CCM multicast address being used. This value
cannot be set to any multicast or broadcast address."
DEFVAL { '000000000000'H }
::= { tnDot1agCfmMaMepListEntry 1 }
tnDot1agCfmMaMepListSapSubType OBJECT-TYPE
SYNTAX INTEGER {
regular (0),
etree-root (1),
etree-leaf (2)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The value of tnDot1agCfmMaMepListSapSubType specifies the SAP
sub type of the remote MEP for the specified MEPID.
This is used to ensure that LLF shutdown is based only on remote
etree-root SAP faults and to suppress unwanted CCM alarms
on etree-leaf SAPs."
DEFVAL { regular }
::= { tnDot1agCfmMaMepListEntry 2 }
-- ******************************************************************
-- The Stack Object. This group will contain all the MIBs objects
-- needed to access the Stack managed object. This group supersedes
-- the dot1agCfmStackTable due to the inclusion of Q-in-Q
-- encapsulation. the VlanIdOrNone object has been expanded to
-- support the full-range of Vlan/Q-in-Q encapsulation. Otherwise
-- this group behaves identically to that of the standard
-- dot1agCfmStackTable.
-- ******************************************************************
-- ******************************************************************
-- The CFM Stack Table
-- ******************************************************************
tnDot1agCfmStackTable OBJECT-TYPE
SYNTAX SEQUENCE OF TnDot1agCfmStackEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"There is one CFM Stack table per bridge. It permits
the retrieval of information about the Maintenance Points
configured on any given interface.
"
REFERENCE
"802.1ag clauses 12.14.2"
::= { tnDot1agCfmStack 2 }
tnDot1agCfmStackEntry OBJECT-TYPE
SYNTAX TnDot1agCfmStackEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The Stack table entry"
INDEX { tnDot1agCfmStackifIndex, tnDot1agCfmStackVlanIdOrNone,
tnDot1agCfmStackMdLevel, tnDot1agCfmStackDirection
}
::= { tnDot1agCfmStackTable 1 }
TnDot1agCfmStackEntry ::= SEQUENCE {
tnDot1agCfmStackifIndex InterfaceIndex,
tnDot1agCfmStackVlanIdOrNone Unsigned32,
tnDot1agCfmStackMdLevel Dot1agCfmMDLevel,
tnDot1agCfmStackDirection Dot1agCfmMpDirection,
tnDot1agCfmStackMdIndex Unsigned32,
tnDot1agCfmStackMaIndex Unsigned32,
tnDot1agCfmStackMepId Dot1agCfmMepIdOrZero,
tnDot1agCfmStackMacAddress MacAddress,
tnDot1agCfmStackMPType INTEGER
}
tnDot1agCfmStackifIndex OBJECT-TYPE
SYNTAX InterfaceIndex
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This object represents the Bridge Port or aggregated port
on which MEPs or MHFs might be configured.
Upon a restart of the system, the system SHALL, if necessary,
change the value of this variable, and rearrange the
dot1agCfmStackTable, so that it indexes the entry in the
interface table with the same value of ifAlias that it
indexed before the system restart. If no such entry exists,
then the system SHALL delete all entries in the
dot1agCfmStackTable with the interface index.
"
REFERENCE
"802.1ag clause 12.14.2.1.2:a"
::= { tnDot1agCfmStackEntry 1 }
tnDot1agCfmStackVlanIdOrNone OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"VLAN ID to which the MP is attached, or 0, if none."
REFERENCE
"802.1ag clauses 12.14.2.1.2:d, 22.1.7"
::= { tnDot1agCfmStackEntry 2 }
tnDot1agCfmStackMdLevel OBJECT-TYPE
SYNTAX Dot1agCfmMDLevel
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"MD Level of the Maintenance Point."
REFERENCE
"802.1ag clause 12.14.2.1.2:b"
::= { tnDot1agCfmStackEntry 3 }
tnDot1agCfmStackDirection OBJECT-TYPE
SYNTAX Dot1agCfmMpDirection
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Direction in which the MP faces on the Bridge Port"
REFERENCE
"802.1ag clause 12.14.2.1.2:c"
::= { tnDot1agCfmStackEntry 4 }
tnDot1agCfmStackMdIndex OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The index of the Maintenance Domain in the dot1agCfmMdTable
to which the MP is associated, or 0, if none."
REFERENCE
"802.1ag clause 12.14.2.1.3:b"
::= { tnDot1agCfmStackEntry 5 }
tnDot1agCfmStackMaIndex OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The index of the MA in the dot1agCfmMaNetTable and
dot1agCfmMaCompTable to which the MP is associated, or 0, if
none."
REFERENCE
"802.1ag clause 12.14.2.1.3:c"
::= { tnDot1agCfmStackEntry 6 }
tnDot1agCfmStackMepId OBJECT-TYPE
SYNTAX Dot1agCfmMepIdOrZero
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"If an MEP is configured, the MEPID, else 0"
REFERENCE
"802.1ag clause 12.14.2.1.3:d"
::= { tnDot1agCfmStackEntry 7 }
tnDot1agCfmStackMacAddress OBJECT-TYPE
SYNTAX MacAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"MAC address of the MP."
REFERENCE
"802.1ag clause 12.14.2.1.3:e"
::= { tnDot1agCfmStackEntry 8 }
tnDot1agCfmStackMPType OBJECT-TYPE
SYNTAX INTEGER {
sap (1),
ethTun (2),
ethRing(3),
facPort(4),
facInterface(5)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of tnDot1agCfmStackMPType indicates the entity that the
MP is configured on:
sap(1) MP is configured on a SAP
ethTun(2) MP is configured on an ethernet-tunnel"
::= { tnDot1agCfmStackEntry 9 }
--
-- Nokia 7x50 product series dot1ag CFM Virtual MEP Stack Table
--
-- This table is a mirror of the dot1agCfmStackTable in IEEE8021-CFM-MIB.
--
-- The indexes of this table differ from that of the dot1agCfmStackTable
-- by the replacement of the dot1agCfmStackIfIndex and
-- dot1agCfmStackVlanIdOrNone indexes with that of the
-- tnDot1agCfmVStackSvcId index.
-- The CFM Virtual Stack Table
-- tnDot1agCfmVStackTable OBJECT-TYPE
-- SYNTAX SEQUENCE OF TnDot1agCfmVStackEntry
-- MAX-ACCESS not-accessible
-- STATUS current
-- DESCRIPTION
-- "There is one CFM Virtual Stack entry per service. It permits
-- the retrieval of information about the Maintenance Points
-- configured on any given virtual Maintenance Association End
-- Point (MEP)."
-- REFERENCE
-- "802.1ag clauses 12.14.2"
-- ::= { tnDot1agCfmStack 3 }
--
-- tnDot1agCfmVStackEntry OBJECT-TYPE
-- SYNTAX TnDot1agCfmVStackEntry
-- MAX-ACCESS not-accessible
-- STATUS current
-- DESCRIPTION
-- "A conceptual row in the tnDot1agCfmVStackTable.
--
-- There exists one row for each configured virtual MEP in the system.
-- Rows are created and destroyed based on the existence of a virtual MEP."
-- INDEX { tnDot1agCfmVStackSvcId,
-- tnDot1agCfmVStackMdLevel,
-- tnDot1agCfmVStackDirection
-- }
-- ::= { tnDot1agCfmVStackTable 1 }
--
-- TnDot1agCfmVStackEntry ::= SEQUENCE {
-- tnDot1agCfmVStackSvcId TmnxServId,
-- tnDot1agCfmVStackMdLevel Dot1agCfmMDLevel,
-- tnDot1agCfmVStackDirection Dot1agCfmMpDirection,
-- tnDot1agCfmVStackMdIndex Unsigned32,
-- tnDot1agCfmVStackMaIndex Unsigned32,
-- tnDot1agCfmVStackMepId Dot1agCfmMepIdOrZero,
-- tnDot1agCfmVStackMacAddress MacAddress
-- }
--
-- tnDot1agCfmVStackSvcId OBJECT-TYPE
-- SYNTAX TmnxServId
-- MAX-ACCESS not-accessible
-- STATUS current
-- DESCRIPTION
-- "The value of tnDot1agCfmVStackSvcId specifies the
-- service on which MEPs might be configured."
-- REFERENCE
-- "802.1ag clause 12.14.2.1.2:a"
-- ::= { tnDot1agCfmVStackEntry 1 }
--
-- tnDot1agCfmVStackMdLevel OBJECT-TYPE
-- SYNTAX Dot1agCfmMDLevel
-- MAX-ACCESS not-accessible
-- STATUS current
-- DESCRIPTION
-- "The value of tnDot1agCfmVStackMdLevel specifies the Maintenance
-- Domain (MD) Level of the Maintenance Point."
-- REFERENCE
-- "802.1ag clause 12.14.2.1.2:b"
-- ::= { tnDot1agCfmVStackEntry 2 }
--
-- tnDot1agCfmVStackDirection OBJECT-TYPE
-- SYNTAX Dot1agCfmMpDirection
-- MAX-ACCESS not-accessible
-- STATUS current
-- DESCRIPTION
-- "The value of tnDot1agCfmVStackDirection specifies the
-- direction in which the Maintenance Point (MP) faces on the service."
-- REFERENCE
-- "802.1ag clause 12.14.2.1.2:c"
-- ::= { tnDot1agCfmVStackEntry 3 }
--
-- tnDot1agCfmVStackMdIndex OBJECT-TYPE
-- SYNTAX Unsigned32
-- MAX-ACCESS read-only
-- STATUS current
-- DESCRIPTION
-- "The value of tnDot1agCfmVStackMdIndex indicates the index
-- of the Maintenance Domain in the dot1agCfmMdTable to which the
-- Maintenance Point (MP) is associated, or 0, if none."
-- REFERENCE
-- "802.1ag clause 12.14.2.1.3:b"
-- ::= { tnDot1agCfmVStackEntry 4 }
--
-- tnDot1agCfmVStackMaIndex OBJECT-TYPE
-- SYNTAX Unsigned32
-- MAX-ACCESS read-only
-- STATUS current
-- DESCRIPTION
-- "The value of tnDot1agCfmVStackMaIndex indicates the index
-- of the Maintenance Association (MA) in the dot1agCfmMaNetTable
-- and dot1agCfmMaCompTable to which the Maintenance Point (MP) is
-- associated, or 0, if none."
-- REFERENCE
-- "802.1ag clause 12.14.2.1.3:c"
-- ::= { tnDot1agCfmVStackEntry 5 }
--
-- tnDot1agCfmVStackMepId OBJECT-TYPE
-- SYNTAX Dot1agCfmMepIdOrZero
-- MAX-ACCESS read-only
-- STATUS current
-- DESCRIPTION
-- "The value of tnDot1agCfmVStackMepId indicates if an MEP
-- is configured, the MEPID, else 0."
-- REFERENCE
-- "802.1ag clause 12.14.2.1.3:d"
-- ::= { tnDot1agCfmVStackEntry 6 }
--
-- tnDot1agCfmVStackMacAddress OBJECT-TYPE
-- SYNTAX MacAddress
-- MAX-ACCESS read-only
-- STATUS current
-- DESCRIPTION
-- "The value of tnDot1agCfmVStackMacAddress indicates
-- the MAC address of the MP."
-- REFERENCE
-- "802.1ag clause 12.14.2.1.3:e"
-- ::= { tnDot1agCfmVStackEntry 7 }
-- Nokia 7x50 product series CFM MIP table
--
-- The MIP tables (Sap and SDP) represent all the service endpoints
-- where Maintenance Domain Intermediate Point (MIP) creation can
-- occur. If a SAP or SDP-Binding does not have a correlating row
-- in these tables, then no MIP will be created for that endpoint.
-- tnDot1agCfmMcLagConfigGroup OBJECT IDENTIFIER ::= {tnDot1agCfmGlobalObjs 1}
-- ******************************************************************
-- The Multi-Chassis LAG Configuration Objects
-- ******************************************************************
tnDot1agCfmMcLagConfigTable OBJECT-TYPE
SYNTAX SEQUENCE OF TnDot1agCfmMcLagConfigEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A row in the tnDot1agCfmMcLagConfigTable indicates whether a Mc Lag
is in Active Standby or not and what the Hold Time will be."
::= { tnDot1agCfmGlobalObjs 1 }
tnDot1agCfmMcLagConfigEntry OBJECT-TYPE
SYNTAX TnDot1agCfmMcLagConfigEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The Cfm entry for MC LAG"
INDEX { tnSysSwitchId }
::= { tnDot1agCfmMcLagConfigTable 1 }
TnDot1agCfmMcLagConfigEntry ::= SEQUENCE {
tnDot1agCfmMcLagConfigStdbyInactive TruthValue,
tnDot1agCfmMcLagConfigPropHoldTime Unsigned32
}
tnDot1agCfmMcLagConfigStdbyInactive OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The value of tnDot1agCfmMcLagConfigStdbyInactive specifies whether or not
ETH-CFM MEPs configured on Multi-Chassis LAG ports are aware of MC-LAG
port active/standby states.
When this object is 'true (1)', MEPs configured on a Multi-Chassis
LAG port will act as if they are administratively shutdown if running
on a standby port, and will only be operational on an active MC-LAG
port.
When this object is 'false (2)', MEPs configured on a Multi-Chassis
LAG port will operate regardless of the MC-LAG port active and standby
states."
DEFVAL { false }
::= { tnDot1agCfmMcLagConfigEntry 1 }
tnDot1agCfmMcLagConfigPropHoldTime OBJECT-TYPE
SYNTAX Unsigned32 (0..60)
UNITS "seconds"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The value of tnDot1agCfmMcLagConfigPropHoldTime specifies the duration, in
seconds, of a timer that is activated when an MC-LAG port or protocol
changes state. While the timer is active, no fault set or clear is
propagated to the MC-LAG SAP's CFM MEP.
The outstanding hold time can be monitored by polling the value of
sapEthCfmMcLagPropHoldTimeRemain for a particular SAP. When set to
the value zero (0), no delay in response to a port or protocol change
will be observed.
This object is meaningful only when tnDot1agCfmMcLagConfigStdbyInactive is
set to the value 'enabled (1)', otherwise an SNMP Set operation will
result in an inconsistentValue error and the result of an SNMP Get
operation will be undefined."
DEFVAL { 1 }
::= { tnDot1agCfmMcLagConfigEntry 2 }
--
-- ******************************************************************
-- The MIP (SAP) Table
-- ******************************************************************
--
-- tnDot1agCfmSapMipTable
-- OBJECT-TYPE
-- SYNTAX SEQUENCE OF TnDot1agCfmSapMipEntry
-- MAX-ACCESS not-accessible
-- STATUS current
-- DESCRIPTION
-- "A row in the tnDot1agCfmSapMipTable indicates that the
-- specified SAP may have a MIP created on the endpoint."
-- ::= { tnDot1agCfmMip 1 }
--
-- tnDot1agCfmSapMipEntry OBJECT-TYPE
-- SYNTAX TnDot1agCfmSapMipEntry
-- MAX-ACCESS not-accessible
-- STATUS current
-- DESCRIPTION
-- "The MIP (SAP) entry"
-- INDEX { tnDot1agCfmSapMipIfIndex, tnDot1agCfmSapMipVlanIdOrNone }
-- ::= { tnDot1agCfmSapMipTable 1 }
--
-- TnDot1agCfmSapMipEntry ::= SEQUENCE {
-- tnDot1agCfmSapMipIfIndex InterfaceIndex,
-- tnDot1agCfmSapMipVlanIdOrNone Unsigned32,
-- tnDot1agCfmSapMipRowStatus RowStatus
-- }
--
-- tnDot1agCfmSapMipIfIndex OBJECT-TYPE
-- SYNTAX InterfaceIndex
-- MAX-ACCESS not-accessible
-- STATUS current
-- DESCRIPTION
-- "This object represents the Bridge Port or aggregated port
-- on which MEPs or MHFs might be configured."
-- ::= { tnDot1agCfmSapMipEntry 1 }
--
-- tnDot1agCfmSapMipVlanIdOrNone OBJECT-TYPE
-- SYNTAX Unsigned32
-- MAX-ACCESS not-accessible
-- STATUS current
-- DESCRIPTION
-- "VLAN ID to which the MIP is attached, or 0, if none."
-- ::= { tnDot1agCfmSapMipEntry 2 }
--
-- tnDot1agCfmSapMipRowStatus OBJECT-TYPE
-- SYNTAX RowStatus
-- MAX-ACCESS read-create
-- STATUS current
-- DESCRIPTION
-- "The tnDot1agCfmSapMipRowStatus specifies the ability to enable MIP
-- creation under a SAP. Existing MIPs associated with the SAP may be
-- viewed via the tnDot1agCfmStackTable"
-- ::= { tnDot1agCfmSapMipEntry 3 }
--
-- ******************************************************************
-- The MIP (SDP) Table
-- ******************************************************************
-- tnDot1agCfmSdpMipTable
-- OBJECT-TYPE
-- SYNTAX SEQUENCE OF TnDot1agCfmSdpMipEntry
-- MAX-ACCESS not-accessible
-- STATUS current
-- DESCRIPTION
-- "A row in the tnDot1agCfmSapMipTable indicates that the
-- specified SDP-Binding may have a MIP created on the endpoint."
-- ::= { tnDot1agCfmMip 2 }
--
-- tnDot1agCfmSdpMipEntry OBJECT-TYPE
-- SYNTAX TnDot1agCfmSdpMipEntry
-- MAX-ACCESS not-accessible
-- STATUS current
-- DESCRIPTION
-- "The MIP (SDP-Binding) entry"
-- INDEX { tnDot1agCfmSdpMipSvcId,
-- tnDot1agCfmSdpMipSdpId,
-- tnDot1agCfmSdpMipVcId
-- }
-- ::= { tnDot1agCfmSdpMipTable 1 }
--
-- TnDot1agCfmSdpMipEntry ::= SEQUENCE {
-- tnDot1agCfmSdpMipSvcId TmnxServId,
-- tnDot1agCfmSdpMipSdpId SdpId,
-- tnDot1agCfmSdpMipVcId Unsigned32,
-- tnDot1agCfmSdpMipRowStatus RowStatus
-- }
--
-- tnDot1agCfmSdpMipSvcId OBJECT-TYPE
-- SYNTAX TmnxServId
-- MAX-ACCESS not-accessible
-- STATUS current
-- DESCRIPTION
-- "The value of tnDot1agCfmSdpMipSvcId specifies the
-- service on which the Sdp-Binding MIP is configured."
-- ::= { tnDot1agCfmSdpMipEntry 1 }
--
-- tnDot1agCfmSdpMipSdpId OBJECT-TYPE
-- SYNTAX SdpId
-- MAX-ACCESS not-accessible
-- STATUS current
-- DESCRIPTION
-- "The value of tnDot1agCfmSdpMipSdpId specifies the
-- Bridge Port or aggregated port on which MEPs or MHFs
-- might be configured."
-- ::= { tnDot1agCfmSdpMipEntry 2 }
--
-- tnDot1agCfmSdpMipVcId OBJECT-TYPE
-- SYNTAX Unsigned32
-- MAX-ACCESS not-accessible
-- STATUS current
-- DESCRIPTION
-- "The value of tnDot1agCfmSdpMipVcId specifies, along with
-- tnDot1agCfmSdpMipSdpId, the SDP Binding for the bridge."
-- ::= { tnDot1agCfmSdpMipEntry 3 }
--
-- tnDot1agCfmSdpMipRowStatus OBJECT-TYPE
-- SYNTAX RowStatus
-- MAX-ACCESS read-create
-- STATUS current
-- DESCRIPTION
-- "The tnDot1agCfmSapMipRowStatus specifies the ability to enable MIP
-- creation under a SAP. Existing MIPs associated with the SAP may be
-- viewed via the tnDot1agCfmSdpBindStackTable"
-- ::= { tnDot1agCfmSdpMipEntry 4 }
--
-- MEP Eth-Test Result Table
--
-- tnDot1agCfmMepEthTestRsltTable OBJECT-TYPE
-- SYNTAX SEQUENCE OF TnDot1agCfmMepEthTestRsltEntry
-- MAX-ACCESS not-accessible
-- STATUS current
-- DESCRIPTION
-- "The tnDot1agCfmMepEthTestRsltTable indicates the results of
-- all eth-tests indexed by the originating MAC addresses.
--
-- This table is not persistent over reboots of the chassis."
-- ::= { tnDot1agCfmMep 2 }
--
-- tnDot1agCfmMepEthTestRsltEntry OBJECT-TYPE
-- SYNTAX TnDot1agCfmMepEthTestRsltEntry
-- MAX-ACCESS not-accessible
-- STATUS current
-- DESCRIPTION
-- "The MEG result table."
-- INDEX {
-- dot1agCfmMdIndex,
-- dot1agCfmMaIndex,
-- dot1agCfmMepIdentifier,
-- tnDot1agCfmMepSrcMacAddress
-- }
-- ::= { tnDot1agCfmMepEthTestRsltTable 1 }
--
-- TnDot1agCfmMepEthTestRsltEntry ::= SEQUENCE {
-- tnDot1agCfmMepSrcMacAddress MacAddress,
-- tnDot1agCfmMepFrameCount Counter32,
-- tnDot1agCfmMepByteCount Counter32,
-- tnDot1agCfmMepFailedBits Counter32,
-- tnDot1agCfmMepCrcFailures Counter32,
-- tnDot1agCfmMepCurrByteCount Gauge32,
-- tnDot1agCfmMepCurrFailedBits Gauge32,
-- tnDot1agCfmMepCurrCrcFailures TruthValue
-- }
--
-- tnDot1agCfmMepSrcMacAddress OBJECT-TYPE
-- SYNTAX MacAddress
-- MAX-ACCESS not-accessible
-- STATUS current
-- DESCRIPTION
-- "The value of tnDot1agCfmMepSrcMacAddress indicates the MAC address
-- of the issuer of the eth-test."
-- ::= { tnDot1agCfmMepEthTestRsltEntry 1 }
--
-- tnDot1agCfmMepFrameCount OBJECT-TYPE
-- SYNTAX Counter32
-- MAX-ACCESS read-only
-- STATUS current
-- DESCRIPTION
-- "The value of tnDot1agCfmMepFrameCount indicates the number of frames
-- received from the issuer of the eth-test."
-- ::= { tnDot1agCfmMepEthTestRsltEntry 2 }
--
-- tnDot1agCfmMepByteCount OBJECT-TYPE
-- SYNTAX Counter32
-- MAX-ACCESS read-only
-- STATUS current
-- DESCRIPTION
-- "The value of tnDot1agCfmMepByteCount indicates the number of bytes
-- received from the issuer of the eth-test."
-- ::= { tnDot1agCfmMepEthTestRsltEntry 3 }
--
-- tnDot1agCfmMepFailedBits OBJECT-TYPE
-- SYNTAX Counter32
-- MAX-ACCESS read-only
-- STATUS current
-- DESCRIPTION
-- "The value of tnDot1agCfmMepFailedBits indicates the accumulated
-- number of bits that did not match the test-pattern in all received
-- Eth-Tst frames since tnDot1agCfmMepEthTestEnable is configured
-- from 'false' to 'true'."
-- ::= { tnDot1agCfmMepEthTestRsltEntry 4 }
--
-- tnDot1agCfmMepCrcFailures OBJECT-TYPE
-- SYNTAX Counter32
-- MAX-ACCESS read-only
-- STATUS current
-- DESCRIPTION
-- "The value of tnDot1agCfmMepCrcFailures indicates the accumulated number
-- of CRC checksum failures."
-- ::= { tnDot1agCfmMepEthTestRsltEntry 5 }
--
-- tnDot1agCfmMepCurrByteCount OBJECT-TYPE
-- SYNTAX Gauge32
-- MAX-ACCESS read-only
-- STATUS current
-- DESCRIPTION
-- "The value of tnDot1agCfmMepCurrByteCount indicates the number of bytes
-- contained in the most recently received Eth-Tst frame Test TLV."
-- ::= { tnDot1agCfmMepEthTestRsltEntry 6 }
--
-- tnDot1agCfmMepCurrFailedBits OBJECT-TYPE
-- SYNTAX Gauge32
-- MAX-ACCESS read-only
-- STATUS current
-- DESCRIPTION
-- "The value of tnDot1agCfmMepCurrFailedBits indicates the number of bits
-- that did not match the test-pattern in the most recently received
-- Eth-Tst frame."
-- ::= { tnDot1agCfmMepEthTestRsltEntry 7 }
--
-- tnDot1agCfmMepCurrCrcFailures OBJECT-TYPE
-- SYNTAX TruthValue
-- MAX-ACCESS read-only
-- STATUS current
-- DESCRIPTION
-- "The value of tnDot1agCfmMepCurrCrcFailures indicates that CRC errors
-- were detected in the most recently received Eth-Tst frame."
-- ::= { tnDot1agCfmMepEthTestRsltEntry 8 }
--
-- MEP Delay Result Table
--
tnDot1agCfmMepDelayRsltTable OBJECT-TYPE
SYNTAX SEQUENCE OF TnDot1agCfmMepDelayRsltEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The tnDot1agCfmMepDelayRsltTable indicates the results of
all the One-Way/Two-Way Delay Tests from the originating MAC
addresses.
This table is not persistent over reboots of the chassis."
::= { tnDot1agCfmMep 3 }
tnDot1agCfmMepDelayRsltEntry OBJECT-TYPE
SYNTAX TnDot1agCfmMepDelayRsltEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The MEG result table."
INDEX {
dot1agCfmMdIndex,
dot1agCfmMaIndex,
dot1agCfmMepIdentifier,
tnDot1agCfmMepDelaySrcMacAddr,
tnDot1agCfmMepDelayTestType
}
::= { tnDot1agCfmMepDelayRsltTable 1 }
TnDot1agCfmMepDelayRsltEntry ::= SEQUENCE {
tnDot1agCfmMepDelaySrcMacAddr MacAddress,
tnDot1agCfmMepDelayTestType INTEGER,
tnDot1agCfmMepDelayTestDelay Integer32,
tnDot1agCfmMepDelayVariation Unsigned32,
tnDot1agCfmMepDelayNearEndTestDelay Integer32,
tnDot1agCfmMepDelayNearEndVariation Unsigned32,
tnDot1agCfmMepDelayFarEndTestDelay Integer32,
tnDot1agCfmMepDelayFarEndVariation Unsigned32
}
tnDot1agCfmMepDelaySrcMacAddr OBJECT-TYPE
SYNTAX MacAddress
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The value of tnDot1agCfmMepDelaySrcMacAddr indicates the source
MAC address of the issuer of the test."
::= { tnDot1agCfmMepDelayRsltEntry 1 }
tnDot1agCfmMepDelayTestType OBJECT-TYPE
SYNTAX INTEGER {
oneWayTest (1),
twoWayTest (2)
}
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The value of tnDot1agCfmMepDelayTestType indicates the type
of test this row details."
::= { tnDot1agCfmMepDelayRsltEntry 2 }
tnDot1agCfmMepDelayTestDelay OBJECT-TYPE
SYNTAX Integer32
UNITS "microseconds"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of tnDot1agCfmMepDelayTestDelay indicates the amount
of time, measured in microseconds, from when the test-frame was
transmitted to the time it was received minus the local processing time
taken by the remote system.
Bi-direction test delay for twoWayTest or oneWayTest"
::= { tnDot1agCfmMepDelayRsltEntry 3 }
tnDot1agCfmMepDelayVariation OBJECT-TYPE
SYNTAX Unsigned32
UNITS "microseconds"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of tnDot1agCfmMepDelayVariation indicates the amount
of time delay variation, measured in microseconds, from the two
most recent time delay measurements.
Bi-direction test delay variation for twoWayTest or oneWayTest"
::= { tnDot1agCfmMepDelayRsltEntry 4 }
tnDot1agCfmMepDelayNearEndTestDelay OBJECT-TYPE
SYNTAX Integer32
UNITS "microseconds"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Near end test delay for oneWayTest."
::= { tnDot1agCfmMepDelayRsltEntry 5 }
tnDot1agCfmMepDelayNearEndVariation OBJECT-TYPE
SYNTAX Unsigned32
UNITS "microseconds"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Near end test delay variation for oneWayTest."
::= { tnDot1agCfmMepDelayRsltEntry 6 }
tnDot1agCfmMepDelayFarEndTestDelay OBJECT-TYPE
SYNTAX Integer32
UNITS "microseconds"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Far end test delay for oneWayTest"
::= { tnDot1agCfmMepDelayRsltEntry 7 }
tnDot1agCfmMepDelayFarEndVariation OBJECT-TYPE
SYNTAX Unsigned32
UNITS "microseconds"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Far end test delay variation for oneWayTest."
::= { tnDot1agCfmMepDelayRsltEntry 8 }
--************************************************************
--add for the MEP-CSF function
--************************************************************
tnDot1agCfmMepCsfTable OBJECT-TYPE
SYNTAX SEQUENCE OF TnDot1agCfmMepCsfEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table augments the Maintenance Association End Point (MEP) table
of the IEEE8021-CFM-MIB."
::= { tnDot1agCfmMep 4 }
tnDot1agCfmMepCsfEntry OBJECT-TYPE
SYNTAX TnDot1agCfmMepCsfEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A conceptual row in the tnDot1agCfmMepCsfTable. This row exists only
if the association dot1agCfmMepEntry is active."
AUGMENTS { dot1agCfmMepEntry }
::= { tnDot1agCfmMepCsfTable 1 }
TnDot1agCfmMepCsfEntry ::= SEQUENCE {
tnDot1agCfmMepCsfInterval Dot1agCfmCcmInterval,
tnDot1agCfmMepCsfDirection INTEGER,
tnDot1agCfmMepCsfPriority Integer32
}
tnDot1agCfmMepCsfInterval OBJECT-TYPE
SYNTAX Dot1agCfmCcmInterval
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Interval between CSF transmissions to be used in the MEP.
"
DEFVAL { interval1min }
::= { tnDot1agCfmMepCsfEntry 1 }
tnDot1agCfmMepCsfDirection OBJECT-TYPE
SYNTAX INTEGER {
disable (1),
unidirection (2),
bi-dirction (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"CSF transmissions direction in the MEP
"
DEFVAL { disable }
::= { tnDot1agCfmMepCsfEntry 2 }
tnDot1agCfmMepCsfPriority OBJECT-TYPE
SYNTAX Integer32 (0..7)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The priority value for CSFs transmitted by the MEP.
Default Value is the highest priority value allowed to pass
through the bridge port for any of this MEPs VIDs.
The management entity can obtain the default value for this
variable from the priority regeneration table by extracting the
highest priority value in this table on this MEPs bridge port.
"
DEFVAL { 7 }
::= { tnDot1agCfmMepCsfEntry 3 }
--
-- MEP Synthetic Loss Measurement two-way Test Config Table
--
tnDot1agCfmMepSlmTWTestTable OBJECT-TYPE
SYNTAX SEQUENCE OF TnDot1agCfmMepSlmTWTestEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"tnDot1agCfmMepSlmTWTestTable consists of the MEP configuration for
issuing individual Synthetic Loss Measurement tests."
REFERENCE "ITU-T Y.1731 Ethernet Synthetic Frame Loss Measurement (ETH-SLM)"
::= { tnDot1agCfmMep 5 }
tnDot1agCfmMepSlmTWTestEntry OBJECT-TYPE
SYNTAX TnDot1agCfmMepSlmTWTestEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"tnDot1agCfmMepSlmTWTestEntry contains the configuration for
generating Synthetic Loss Measurement (SLM) Tests for a particular MEP.
A row exists for each row in the dot1agCfmMepTable, and is destroyed
automatically with the removal of a row in the dot1agCfmMepTable.
Results from a two-way SLM test are reported in
tnDot1agCfmMepSlmTestRsltTable with the tnDot1agCfmMepSlmTestType
set to 'twoWayTest (2)'."
AUGMENTS { dot1agCfmMepEntry }
::= { tnDot1agCfmMepSlmTWTestTable 1 }
TnDot1agCfmMepSlmTWTestEntry ::= SEQUENCE {
tnDot1agCfmMepSlmTWTestStatus TmnxEnabledDisabled,
tnDot1agCfmMepSlmTWTestId Unsigned32,
tnDot1agCfmMepSlmTWMacAddress MacAddress,
tnDot1agCfmMepSlmTWPriority Unsigned32,
tnDot1agCfmMepSlmTWInterval Unsigned32,
tnDot1agCfmMepSlmTWTimeout Unsigned32,
tnDot1agCfmMepSlmTWDataSize Unsigned32,
tnDot1agCfmMepSlmTWSendCount Unsigned32,
tnDot1agCfmMepSlmTWIntervalRedef Unsigned32,
tnDot1agCfmMepSlmTWIntrvlUnits INTEGER
}
tnDot1agCfmMepSlmTWTestStatus OBJECT-TYPE
SYNTAX TmnxEnabledDisabled
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The value of tnDot1agCfmMepSlmTWTestStatus specifies the operational
state of the two-way Synthetic Loss Measurement (SLM) test.
To issue a two-way SLM test the user must issue an SNMP SET on this
object with a value 'enabled (1)'. To abort the two-way SLM test issue
an SNMP SET on this object with the value 'disabled (2)'.
A read on this object represents the current state of the two-way SLM
test:
enabled (1) - The test is actively running, and attempts at
modifying any two-way SLM object will be rejected
disabled (2) - The test is not running.
Once the test is complete this object will revert to the default value
'disabled (2)'."
DEFVAL { disabled }
::= { tnDot1agCfmMepSlmTWTestEntry 1 }
tnDot1agCfmMepSlmTWTestId OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of tnDot1agCfmMepSlmTWTestId indicates the test identifier
used to initiate the two-way Synthetic Loss Measurement (SLM) test."
::= { tnDot1agCfmMepSlmTWTestEntry 2 }
tnDot1agCfmMepSlmTWMacAddress OBJECT-TYPE
SYNTAX MacAddress
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The value of tnDot1agCfmMepSlmTWMacAddress specifies the MAC address
used as a target for the two-way Synthetic Loss Measurement (SLM) test.
This object MUST be set to a valid MAC Address for proper execution of
the two-way SLM test."
DEFVAL { '000000000000'H }
::= { tnDot1agCfmMepSlmTWTestEntry 3 }
tnDot1agCfmMepSlmTWPriority OBJECT-TYPE
SYNTAX Unsigned32 (0..7)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The value of tnDot1agCfmMepSlmTWPriority specifies the priority used
in the generated test frame for the two-way Synthetic Loss Measurement
(SLM) test."
DEFVAL { 7 }
::= { tnDot1agCfmMepSlmTWTestEntry 4 }
tnDot1agCfmMepSlmTWInterval OBJECT-TYPE
SYNTAX Unsigned32 (1..5000)
UNITS "seconds"
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The value of tnDot1agCfmMepSlmTWInterval specifies the delay, in
seconds, between Synthetic Loss Measurement (SLM) messages for the
two-way SLM test.
Following are the allowed value for 1830 TPS:
{33, 100, 1000} - all values in decimilliseconds
{1, 10, 60, 600} - all values in seconds"
DEFVAL { 5 }
::= { tnDot1agCfmMepSlmTWTestEntry 5 }
tnDot1agCfmMepSlmTWTimeout OBJECT-TYPE
SYNTAX Unsigned32 (1..10)
UNITS "seconds"
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The value of tnDot1agCfmMepSlmTWTimeout specifies the time-out value,
in seconds, to wait for a Synthetic Loss Measurement (SLM) message to
reply for the two-way SLM test. Upon expiration of the timeout period,
the agent assumes that the message response will not be received. Any
response received after the timeout period has expired is silently
discarded."
DEFVAL { 5 }
::= { tnDot1agCfmMepSlmTWTestEntry 6 }
tnDot1agCfmMepSlmTWDataSize OBJECT-TYPE
SYNTAX Unsigned32 (0..9558)
UNITS "bytes"
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The value of tnDot1agCfmMepSlmTWDataSize specifies the data size,
in bytes, contained in the padding TLV for the two-way Synthetic Loss
Measurement (SLM) test. A value of zero (0) specifies that no padding
TLV is inserted in the SLM packet. Any non-zero value will increase
the packet size by the specified data size plus 3 bytes for the TLV
header."
DEFVAL { 0 }
::= { tnDot1agCfmMepSlmTWTestEntry 7 }
tnDot1agCfmMepSlmTWSendCount OBJECT-TYPE
SYNTAX Unsigned32(1..1000)
UNITS "packets"
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The value of tnDot1agCfmMepSlmTWSendCount specifies the number of
Synthetic Loss Measurement (SLM) packets to send during the two-way
SLM test."
DEFVAL { 1 }
::= { tnDot1agCfmMepSlmTWTestEntry 8 }
tnDot1agCfmMepSlmTWIntervalRedef OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The value of tnDot1agCfmMepSlmTWIntervalRedef specifies the interval
of SLM frames transmitted.
The permitted values are 100ms(0),1s (1),10s(2),1m(3),10(4)."
DEFVAL { 1 }
::= { tnDot1agCfmMepSlmTWTestEntry 9 }
tnDot1agCfmMepSlmTWIntrvlUnits OBJECT-TYPE
SYNTAX INTEGER {
seconds(1),
centiseconds(2),
decimilliseconds(3)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The value of tnDot1agCfmMepSlmTWIntrvlUnits, in conjuction with
tnDot1agCfmMepSlmTWInterval, specifies the interval between Synthetic
Loss Measurement (SLM) messages sent by the two-way SLM test. For
example, if tnDot1agCfmMepSlmTWInterval has the value 90, and
tnDot1agCfmMepSlmTWIntrvlUnits has the value 'centiseconds(2)', the
interval between SLM messages is 0.9 seconds.
For example, if tnDot1agCfmMepSlmTWInterval has the value 33, and
tnDot1agCfmMepSlmTWIntrvlUnits has the value 'decimilliseconds (3)',
the interval between SLM messages is 3.3 milliseconds.
The intervals supported are shown in the tnDot1agCfmMepSlmTWInterval
DESCRIPTION clause.
"
DEFVAL { seconds }
::= { tnDot1agCfmMepSlmTWTestEntry 10 }
tnDot1agCfmStatisticsGroup OBJECT IDENTIFIER ::= {tnDot1agCfmGlobalObjs 3}
tnDot1agCfmComponentLimitTable OBJECT-TYPE
SYNTAX SEQUENCE OF TnDot1agCfmComponentLimitEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The tnDot1agCfmComponentLimitTable stores the current resource counts
as well as their resource limits for Ethernet Connectivity Fault
Management (ETH-CFM) components in the SROS series system."
::= { tnDot1agCfmStatisticsGroup 1 }
tnDot1agCfmComponentLimitEntry OBJECT-TYPE
SYNTAX TnDot1agCfmComponentLimitEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The tnDot1agCfmComponentLimitEntry consists of the resource limits
for a particular component of ETH-CFM.
Rows are managed by the system and can not be created or destroyed using
SNMP set requests."
INDEX { tnSysSwitchId,
tnDot1agCfmCompMajorIndex,
tnDot1agCfmCompMinorIndex
}
::= { tnDot1agCfmComponentLimitTable 1 }
TnDot1agCfmComponentLimitEntry ::= SEQUENCE {
tnDot1agCfmCompMajorIndex Unsigned32,
tnDot1agCfmCompMinorIndex Unsigned32,
tnDot1agCfmCompName TNamedItem,
tnDot1agCfmCompResourceUsage Unsigned32,
tnDot1agCfmCompResourceLimit Unsigned32
}
tnDot1agCfmCompMajorIndex OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The value of tnDot1agCfmCompMajorIndex specifies the major identifier
of the ETH-CFM component."
::= { tnDot1agCfmComponentLimitEntry 1 }
tnDot1agCfmCompMinorIndex OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The value of tnDot1agCfmCompMinorIndex specifies the minor identifier
of the ETH-CFM component."
::= { tnDot1agCfmComponentLimitEntry 2 }
tnDot1agCfmCompName OBJECT-TYPE
SYNTAX TNamedItem
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of tnDot1agCfmCompName indicates the name of the ETH-CFM
component."
::= { tnDot1agCfmComponentLimitEntry 3 }
tnDot1agCfmCompResourceUsage OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of tnDot1agCfmCompResourceUsage indicates the current
resource usage for the ETH-CFM component."
::= { tnDot1agCfmComponentLimitEntry 4 }
tnDot1agCfmCompResourceLimit OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of tnDot1agCfmCompResourceLimit indicates the maximum
resource usage limit for the ETH-CFM component for the
SROS series system."
::= { tnDot1agCfmComponentLimitEntry 5 }
--
-- MEP Synthetic Loss Measurement one-way Test Config Table
--
tnDot1agCfmMepSlmOWTestTable OBJECT-TYPE
SYNTAX SEQUENCE OF TnDot1agCfmMepSlmOWTestEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"tnDot1agCfmMepSlmOWTestTable consists of the MEP configuration for
issuing individual Synthetic Loss Measurement one-way tests."
REFERENCE "ITU-T Y.1731 Ethernet Synthetic Frame Loss Measurement (ETH-SLM)"
::= { tnDot1agCfmMep 6 }
tnDot1agCfmMepSlmOWTestEntry OBJECT-TYPE
SYNTAX TnDot1agCfmMepSlmOWTestEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"tnDot1agCfmMepSlmOWTestEntry contains the configuration for
generating Synthetic Loss Measurement (SLM) Tests for a particular MEP.
A row exists for each row in the dot1agCfmMepTable, and is destroyed
automatically with the removal of a row in the dot1agCfmMepTable.
Results from a one-way SLM test are reported in
tnDot1agCfmMepSlmTestRsltTable with tnDot1agCfmMepSlmTestType set
to 'oneWayTest (1)'."
AUGMENTS { dot1agCfmMepEntry }
::= { tnDot1agCfmMepSlmOWTestTable 1 }
TnDot1agCfmMepSlmOWTestEntry ::= SEQUENCE {
tnDot1agCfmMepSlmOWTestStatus TmnxEnabledDisabled,
tnDot1agCfmMepSlmOWTestId Unsigned32,
tnDot1agCfmMepSlmOWMacAddress MacAddress,
tnDot1agCfmMepSlmOWPriority Unsigned32,
tnDot1agCfmMepSlmOWInterval Unsigned32,
tnDot1agCfmMepSlmOWDataSize Unsigned32,
tnDot1agCfmMepSlmOWSendCount Unsigned32
}
tnDot1agCfmMepSlmOWTestStatus OBJECT-TYPE
SYNTAX TmnxEnabledDisabled
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The value of tnDot1agCfmMepSlmOWTestStatus specifies the operational
state of the one-way Synthetic Loss Measurement (SLM) test.
To issue a one-way SLM test the user must issue an SNMP SET on this
object with a value 'enabled (1)'. To abort the one-way SLM test issue
an SNMP SET on this object with the value 'disabled (2)'.
A read on this object represents the current state of the one-way SLM
test:
enabled (1) - The test is actively running, and attempts at
modifying any one-way SLM object will be rejected
disabled (2) - The test is not running.
Once the test is complete this object will revert to the default value
'disabled (2)'."
DEFVAL { disabled }
::= { tnDot1agCfmMepSlmOWTestEntry 1 }
tnDot1agCfmMepSlmOWTestId OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of tnDot1agCfmMepSlmOWTestId indicates the test identifier
used to initiate the one-way Synthetic Loss Measurement (SLM) test."
::= { tnDot1agCfmMepSlmOWTestEntry 2 }
tnDot1agCfmMepSlmOWMacAddress OBJECT-TYPE
SYNTAX MacAddress
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The value of tnDot1agCfmMepSlmOWMacAddress specifies the MAC address
used as a target for the one-way Synthetic Loss Measurement (SLM) Test.
This object MUST be set to a valid MAC Address for proper execution of
the one-way SLM test."
DEFVAL { '000000000000'H }
::= { tnDot1agCfmMepSlmOWTestEntry 3 }
tnDot1agCfmMepSlmOWPriority OBJECT-TYPE
SYNTAX Unsigned32 (0..7)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The value of tnDot1agCfmMepSlmOWPriority specifies the priority used
in the generated test frame for the one-way Synthetic Loss Measurement
(SLM) test."
DEFVAL { 7 }
::= { tnDot1agCfmMepSlmOWTestEntry 4 }
tnDot1agCfmMepSlmOWInterval OBJECT-TYPE
SYNTAX Unsigned32 (1..10)
UNITS "seconds"
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The value of tnDot1agCfmMepSlmOWInterval specifies the delay, in
seconds, between Synthetic Loss Measurement (SLM) messages for the
one-way SLM test."
DEFVAL { 5 }
::= { tnDot1agCfmMepSlmOWTestEntry 5 }
tnDot1agCfmMepSlmOWDataSize OBJECT-TYPE
SYNTAX Unsigned32 (0..1500)
UNITS "bytes"
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The value of tnDot1agCfmMepSlmOWDataSize specifies the data size,
in bytes, contained in the padding TLV for the one-way Synthetic Loss
Measurement (SLM) test. A value of zero (0) specifies that no padding
TLV is inserted in the SLM packet. Any non-zero value will increase
the packet size by the specified data size plus 3 bytes for the TLV
header."
DEFVAL { 0 }
::= { tnDot1agCfmMepSlmOWTestEntry 6 }
tnDot1agCfmMepSlmOWSendCount OBJECT-TYPE
SYNTAX Unsigned32(1..100)
UNITS "packets"
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The value of tnDot1agCfmMepSlmOWSendCount specifies the number of
Synthetic Loss Measurement (SLM) packets to send consecutively during
the one-way SLM test."
DEFVAL { 1 }
::= { tnDot1agCfmMepSlmOWTestEntry 7 }
--
-- MEP Synthetic Loss Measurement Test Results Table
--
tnDot1agCfmMepSlmTestRsltTable OBJECT-TYPE
SYNTAX SEQUENCE OF TnDot1agCfmMepSlmTestRsltEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"tnDot1agCfmMepSlmTestRsltTable consists of the results of manually
triggered Synthetic Loss Measurement tests."
::= { tnDot1agCfmMep 7 }
tnDot1agCfmMepSlmTestRsltEntry OBJECT-TYPE
SYNTAX TnDot1agCfmMepSlmTestRsltEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"tnDot1agCfmMepSlmTestRsltEntry contains the results of a
manually triggered Synthetic Loss Measurement (SLM) test for a
particular MEP. Rows are auto-generated by the system based on the
issuing of a SLM test."
INDEX {
dot1agCfmMdIndex,
dot1agCfmMaIndex,
dot1agCfmMepIdentifier,
tnDot1agCfmMepSlmTestType,
tnDot1agCfmMepSlmRemoteMacAddr
}
::= { tnDot1agCfmMepSlmTestRsltTable 1 }
TnDot1agCfmMepSlmTestRsltEntry ::= SEQUENCE {
tnDot1agCfmMepSlmTestType INTEGER,
tnDot1agCfmMepSlmRemoteMacAddr MacAddress,
tnDot1agCfmMepSlmTestId Unsigned32,
tnDot1agCfmMepSlmRemoteMepId Dot1agCfmMepId,
tnDot1agCfmMepSlmLastTxSeqF Unsigned32,
tnDot1agCfmMepSlmPacketIn Counter32,
tnDot1agCfmMepSlmPacketLossIn Integer32,
tnDot1agCfmMepSlmPacketLossOut Integer32,
tnDot1agCfmMepSlmPacketUnack Gauge32
}
tnDot1agCfmMepSlmTestType OBJECT-TYPE
SYNTAX INTEGER {
oneWayTest (1),
twoWayTest (2)
}
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The value of tnDot1agCfmMepSlmTestType specifies whether the
row for this Synthetic Loss Measurement (SLM) test refers to a two-way
SLM test."
::= { tnDot1agCfmMepSlmTestRsltEntry 1 }
tnDot1agCfmMepSlmRemoteMacAddr OBJECT-TYPE
SYNTAX MacAddress
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The value of tnDot1agCfmMepSlmRemoteMacAddr specifies the source MAC
address of the remote node involved in the test."
::= { tnDot1agCfmMepSlmTestRsltEntry 2 }
tnDot1agCfmMepSlmTestId OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of tnDot1agCfmMepSlmTestId indicates the test identifier
that was used to initiate the Synthetic Loss Measurement (SLM) test."
::= { tnDot1agCfmMepSlmTestRsltEntry 3 }
tnDot1agCfmMepSlmRemoteMepId OBJECT-TYPE
SYNTAX Dot1agCfmMepId
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of tnDot1agCfmMepSlmRemoteMepId indicates the MEP
Identifier of the remote node involved in the test."
::= { tnDot1agCfmMepSlmTestRsltEntry 4 }
tnDot1agCfmMepSlmLastTxSeqF OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of tnDot1agCfmMepSlmLastTxSeqF indicates the last
received sequence number on the local node, transmitted by the
remote node."
REFERENCE "ITU-T Y.1731 Ethernet Synthetic Frame Loss Measurement (ETH-SLM)"
::= { tnDot1agCfmMepSlmTestRsltEntry 5 }
tnDot1agCfmMepSlmPacketIn OBJECT-TYPE
SYNTAX Counter32
UNITS "packets"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of tnDot1agCfmMepSlmPacketIn indicates the number of
packets received during the execution of the test."
REFERENCE "ITU-T Y.1731 Ethernet Synthetic Frame Loss Measurement (ETH-SLM)"
::= { tnDot1agCfmMepSlmTestRsltEntry 6 }
tnDot1agCfmMepSlmPacketLossIn OBJECT-TYPE
SYNTAX Integer32
UNITS "packets"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of tnDot1agCfmMepSlmPacketLossIn indicates the number of
packets transmitted from the remote node but not received on the local
node during the execution of the test."
REFERENCE "ITU-T Y.1731 Ethernet Synthetic Frame Loss Measurement (ETH-SLM)"
::= { tnDot1agCfmMepSlmTestRsltEntry 7 }
tnDot1agCfmMepSlmPacketLossOut OBJECT-TYPE
SYNTAX Integer32
UNITS "packets"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of tnDot1agCfmMepSlmPacketLossOut indicates the number of
packets transmitted from the local node but not received on the remote
node during the execution of the test."
REFERENCE "ITU-T Y.1731 Ethernet Synthetic Frame Loss Measurement (ETH-SLM)"
::= { tnDot1agCfmMepSlmTestRsltEntry 8 }
tnDot1agCfmMepSlmPacketUnack OBJECT-TYPE
SYNTAX Gauge32
UNITS "packets"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of tnDot1agCfmMepSlmPacketUnack indicates the number of
unacknowledged lost packets during the execution of the test."
REFERENCE "ITU-T Y.1731 Ethernet Synthetic Frame Loss Measurement (ETH-SLM)"
::= { tnDot1agCfmMepSlmTestRsltEntry 9 }
--************************************************************
-- MEP regular LM function
--************************************************************
tnDot1agCfmMepOndemandLmTestTable OBJECT-TYPE
SYNTAX SEQUENCE OF TnDot1agCfmMepOndemandLmTestEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"tnDot1agCfmMepOndemandLmTestTable consists of the MEP configuration for
issuing individual on-demand Regular Loss Measurement tests."
REFERENCE "ITU-T Y.1731 Ethernet Frame Loss Measurement (ETH-LM)"
::= { tnDot1agCfmMep 8 }
tnDot1agCfmMepOndemandLmTestEntry OBJECT-TYPE
SYNTAX TnDot1agCfmMepOndemandLmTestEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"tnDot1agCfmMepOndemandLmTestEntry contains the configuration for
generating regular Loss Measurement (LM) Tests for a particular MEP.
A row exists for each row in the dot1agCfmMepTable, and is destroyed
automatically with the removal of a row in the dot1agCfmMepTable.
Results from a on-demand regualar LM test are reported in
tnDot1agCfmMepOndemandLmTestRsltTable."
AUGMENTS { dot1agCfmMepEntry }
::= { tnDot1agCfmMepOndemandLmTestTable 1 }
TnDot1agCfmMepOndemandLmTestEntry ::= SEQUENCE {
tnDot1agCfmMepOndemandLmTestStatus TmnxEnabledDisabled,
tnDot1agCfmMepOndemandLmDestMacAddress MacAddress,
tnDot1agCfmMepOndemandLmPriority Unsigned32,
tnDot1agCfmMepOndemandLmInterval Dot1agCfmCcmInterval,
tnDot1agCfmMepOndemandLmSendCount Unsigned32,
tnDot1agCfmMepOndemandLmTimeout Unsigned32
}
tnDot1agCfmMepOndemandLmTestStatus OBJECT-TYPE
SYNTAX TmnxEnabledDisabled
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The value of tnDot1agCfmMepOndemandLmTestStatus specifies the operational
state of the on-demand regular Loss Measurement (LM) test.
To issue a on-demand regular LM test the user must issue an SNMP SET on this
object with a value 'enabled (1)'. To abort the on-demand regular LM test issue
an SNMP SET on this object with the value 'disabled (2)'.
A read on this object represents the current state of the two-way SLM
test:
enabled (1) - The test is actively running, and attempts at
modifying any on-demand regular LM object will be rejected
disabled (2) - The test is not running.
Once the test is complete this object will revert to the default value
'disabled (2)'."
DEFVAL { disabled }
::= { tnDot1agCfmMepOndemandLmTestEntry 1 }
tnDot1agCfmMepOndemandLmDestMacAddress OBJECT-TYPE
SYNTAX MacAddress
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The value of tnDot1agCfmMepOndemandLmMacAddress specifies the MAC address
used as a target for the on-demand regular Loss Measurement (LM) test.
This object MUST be set to a valid MAC Address for proper execution of
the on-demand regular LM test."
DEFVAL { '000000000000'H }
::= { tnDot1agCfmMepOndemandLmTestEntry 2 }
tnDot1agCfmMepOndemandLmPriority OBJECT-TYPE
SYNTAX Unsigned32 (0..7)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The value of tnDot1agCfmMepOndemandLmPriority specifies the priority used
in the generated test frame for the on-demand regular Loss Measurement
(LM) test."
DEFVAL { 7 }
::= { tnDot1agCfmMepOndemandLmTestEntry 3 }
tnDot1agCfmMepOndemandLmInterval OBJECT-TYPE
SYNTAX Dot1agCfmCcmInterval
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The value of tnDot1agCfmMepOndemandLmInterval specifies the delay, in
seconds, between on-demand regular Loss Measurement (LM) messages for the
on-demand regular LM test.
allowed values: 100ms, 1s(default), 10s, 1m, 10m."
DEFVAL { interval1s }
::= { tnDot1agCfmMepOndemandLmTestEntry 4 }
tnDot1agCfmMepOndemandLmSendCount OBJECT-TYPE
SYNTAX Unsigned32(2..101)
UNITS "packets"
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The value of tnDot1agCfmMepOndemandLmSendCount specifies the number of
LMM packets to send during the on-demand regular
LM test."
DEFVAL { 2 }
::= { tnDot1agCfmMepOndemandLmTestEntry 5 }
tnDot1agCfmMepOndemandLmTimeout OBJECT-TYPE
SYNTAX Unsigned32 (1000..10000)
UNITS "milliseconds"
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The value of tnDot1agCfmMepOndemandLmTimeout specifies the time-out value,
in milliseconds, to wait for a response message for the two-way LM test.
Upon expiration of the timeout period, the agent assumes that the response
message will not be received. Any response received after the timeout period
has expired is silently discarded."
DEFVAL { 1000 }
::= { tnDot1agCfmMepOndemandLmTestEntry 6 }
--
-- MEP On-demand regular Loss Measurement Test Results Table
--
tnDot1agCfmMepOndemandLmTestRsltTable OBJECT-TYPE
SYNTAX SEQUENCE OF TnDot1agCfmMepOndemandLmTestRsltEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"tnDot1agCfmMepOndemandLmTestRsltTable consists of the results of manually
triggered on-demand regular Loss Measurement tests."
::= { tnDot1agCfmMep 9 }
tnDot1agCfmMepOndemandLmTestRsltEntry OBJECT-TYPE
SYNTAX TnDot1agCfmMepOndemandLmTestRsltEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"tnDot1agCfmMepOndemandLmTestRsltEntry contains the results of a
manually triggered on-demand regular Loss Measurement (LM) test.
Rows are auto-generated by the system based on the
issuing of a on-demand regular LM test."
INDEX {
dot1agCfmMdIndex,
dot1agCfmMaIndex,
dot1agCfmMepIdentifier
}
::= { tnDot1agCfmMepOndemandLmTestRsltTable 1 }
TnDot1agCfmMepOndemandLmTestRsltEntry ::= SEQUENCE {
tnDot1agCfmMepOndemandLmTnTF Counter32,
tnDot1agCfmMepOndemandLmTnLF Counter32,
tnDot1agCfmMepOndemandLmTfTF Counter32,
tnDot1agCfmMepOndemandLmTfLF Counter32,
tnDot1agCfmMepOndemandLmUnack Gauge32,
tnDot1agCfmMepOndemandLmRemoteMacAddr MacAddress
}
tnDot1agCfmMepOndemandLmTnTF OBJECT-TYPE
SYNTAX Counter32
UNITS "packets"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of tnDot1agCfmMepOndemandLmTnTF indicates the total number of
near-end transmitted service frames from the remote node during the
execution of the test."
REFERENCE "ITU-T Y.1731 Ethernet Frame Single-ended Loss Measurement (ETH-LM)"
::= { tnDot1agCfmMepOndemandLmTestRsltEntry 1 }
tnDot1agCfmMepOndemandLmTnLF OBJECT-TYPE
SYNTAX Counter32
UNITS "packets"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of tnDot1agCfmMepOndemandLmTnLF indicates the total number of
near-end lost service frames on the local node during the execution of
the test."
REFERENCE "ITU-T Y.1731 Ethernet Frame Single-ended Loss Measurement (ETH-LM)"
::= { tnDot1agCfmMepOndemandLmTestRsltEntry 2 }
tnDot1agCfmMepOndemandLmTfTF OBJECT-TYPE
SYNTAX Counter32
UNITS "packets"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of tnDot1agCfmMepOndemandLmTfTF indicates the total number of
far-end transmitted service frames from the local node during the
execution of the test."
REFERENCE "ITU-T Y.1731 Ethernet Frame Single-ended Loss Measurement (ETH-LM)"
::= { tnDot1agCfmMepOndemandLmTestRsltEntry 3 }
tnDot1agCfmMepOndemandLmTfLF OBJECT-TYPE
SYNTAX Counter32
UNITS "packets"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of tnDot1agCfmMepOndemandLmTfLF indicates the total number of
far-end lost service frames on the remote node during the execution of
the test."
REFERENCE "ITU-T Y.1731 Ethernet Frame Single-ended Loss Measurement (ETH-LM)"
::= { tnDot1agCfmMepOndemandLmTestRsltEntry 4 }
tnDot1agCfmMepOndemandLmUnack OBJECT-TYPE
SYNTAX Gauge32
UNITS "packets"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of tnDot1agCfmMepOndemandLmUnack indicates the number of
unacknowledged lost LM packets during the execution of the test."
REFERENCE "ITU-T Y.1731 Ethernet Frame Single-ended Loss Measurement (ETH-LM)"
::= { tnDot1agCfmMepOndemandLmTestRsltEntry 5 }
tnDot1agCfmMepOndemandLmRemoteMacAddr OBJECT-TYPE
SYNTAX MacAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The MAC address of the remote node involved in the test."
::= { tnDot1agCfmMepOndemandLmTestRsltEntry 6 }
--
-- MEP one-way Delay Result extension Table
--
tnDot1agCfmMepOWDelayRsltExtTable OBJECT-TYPE
SYNTAX SEQUENCE OF TnDot1agCfmMepOWDelayRsltExtEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The tnDot1agCfmMepOWDelayRsltExtTable indicates the near-end One-way
Delay result.
This table is not persistent over reboots of the chassis."
::= { tnDot1agCfmMep 10 }
tnDot1agCfmMepOWDelayRsltExtEntry OBJECT-TYPE
SYNTAX TnDot1agCfmMepOWDelayRsltExtEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The near-end one-way delay test result table."
INDEX {
dot1agCfmMdIndex,
dot1agCfmMaIndex,
dot1agCfmMepIdentifier
}
::= { tnDot1agCfmMepOWDelayRsltExtTable 1 }
TnDot1agCfmMepOWDelayRsltExtEntry ::= SEQUENCE {
tnDot1agCfmMepOWDelayRsltExtTnFD Integer32,
tnDot1agCfmMepOWDelayRsltExtTnFDV Integer32
}
tnDot1agCfmMepOWDelayRsltExtTnFD OBJECT-TYPE
SYNTAX Integer32
UNITS "microseconds"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of tnDot1agCfmMepOWDelayRsltExtTnFD indicates one-way
near-end frame delay from remote MEP to local MEP. It is the amount
of time, measured in microseconds, from when the test-frame was
transmitted by the remote MEP to the time it was received local MEP."
::= { tnDot1agCfmMepOWDelayRsltExtEntry 1 }
tnDot1agCfmMepOWDelayRsltExtTnFDV OBJECT-TYPE
SYNTAX Integer32
UNITS "microseconds"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of tnDot1agCfmMepDelayVariation indicates the amount of
near-end one-way time delay variation, measured in microseconds,
from the two most recent near-end one-way time delay measurements"
::= { tnDot1agCfmMepOWDelayRsltExtEntry 2 }
--
-- Dummy Scalars
--
tnDot1agCfmMepScalar1 OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A dummy scalar that satisfies a SNMP get request quickly when
there is no 11QPE24 card provisioned. Otherwise, it has to
traverse the remaining 11QPE24 MIB to get to the next applicable
item."
::= { tnDot1agCfmMep 101 }
tnDot1agCfmMepScalar2 OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"."
::= { tnDot1agCfmMep 102 }
--
-- Notification Objects
--
-- tnDot1agCfmNotifySvcId OBJECT-TYPE
-- SYNTAX TmnxServId
-- MAX-ACCESS accessible-for-notify
-- STATUS current
-- DESCRIPTION
-- "The tnDot1agCfmNotifySvcId is used in notifications when a row
-- consisting of the service identifier may not exist when the trap
-- is issued."
-- ::= { tnDot1agCfmNotificationObjs 1 }
-- ******************************************************************
-- The Synthetic Loss Measurement Configuration Objects
-- ******************************************************************
-- tnDot1agCfmSLMConfigGroup OBJECT IDENTIFIER ::= {tnDot1agCfmGlobalObjs 2}
--
-- Dummy Scalars
--
tnDot1agCfmGlobalScalar1 OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A dummy scalar that satisfies a SNMP get request quickly when
there is no 11QPE24 card provisioned. Otherwise, it has to
traverse the remaining 11QPE24 MIB to get to the next applicable
item."
::= { tnDot1agCfmGlobalObjs 101 }
tnDot1agCfmGlobalScalar2 OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"."
::= { tnDot1agCfmGlobalObjs 102 }
-- tnDot1agCfmSLMInactivityTimer OBJECT-TYPE
-- SYNTAX Unsigned32 (10..100)
-- UNITS "seconds"
-- MAX-ACCESS read-write
-- STATUS current
-- DESCRIPTION
-- "The value of tnDot1agCfmSLMInactivityTimer specifies the duration,
-- in seconds, that the system will maintain Synthetic Loss Measurement
-- (SLM) reply (SLR) data for individual two-way tests in the absence of
-- receiving SLM frames.
--
-- The system may be blocked in responding to new two-way SLM tests due to
-- an excessive inactive timer duration. In this case, reducing this
-- object's value, thus reducing the retention time for existing latent
-- SLR test data, will help free test resources allowing the system to
-- respond to new two-way SLM tests."
-- REFERENCE "ITU-T Y.1731 Ethernet Synthetic Frame Loss Measurement (ETH-SLM)
-- Section 8.2 Note 2."
-- DEFVAL { 100 }
-- ::= { tnDot1agCfmSLMConfigGroup 1 }
--
-- Notifications
--
tnDot1agCfmMepLbmTestComplete NOTIFICATION-TYPE
OBJECTS {
dot1agCfmMepTransmitLbmDestMacAddress
}
STATUS current
DESCRIPTION
"The tnDot1agCfmMepLbmTestComplete notification indicates that
a loopback test has been issued and results are ready."
::= { tnDot1agNotifications 1 }
tnDot1agCfmMepLtmTestComplete NOTIFICATION-TYPE
OBJECTS {
dot1agCfmMepTransmitLtmSeqNumber
}
STATUS current
DESCRIPTION
"The tnDot1agCfmMepLtmTestComplete notification indicates that
a linktrace test has been issued and results are ready. The
dot1agCfmMepTransmitLtmSeqNumber indicates the Transaction
Identifier to use to retrieve the Link-trace results."
::= { tnDot1agNotifications 2 }
-- tnDot1agCfmMepEthTestComplete NOTIFICATION-TYPE
-- OBJECTS {
-- tnDot1agCfmMepCurrByteCount,
-- tnDot1agCfmMepCurrFailedBits,
-- tnDot1agCfmMepCurrCrcFailures
-- }
-- STATUS current
-- DESCRIPTION
-- "The tnDot1agCfmMepEthTestComplete notification indicates that
-- an eth-test has been issued and results are ready. The
-- tnDot1agCfmMepCurrByteCount indicates the number of bytes contained in
-- the frame's Test TLV, and the tnDot1agCfmMepCurrFailedBits and
-- tnDot1agCfmMepCurrCrcFailures indicate the failure state of the
-- test. A value of Zero (0) for tnDot1agCfmMepCurrFailedBits and a
-- value of 'false (2)' for tnDot1agCfmMepCurrCrcFailures indicates
-- a successful test."
-- ::= { tnDot1agNotifications 3 }
tnDot1agCfmMepDMTestComplete NOTIFICATION-TYPE
OBJECTS {
tnDot1agCfmMepDelayTestDelay
}
STATUS current
DESCRIPTION
"The tnDot1agCfmMepDMTestComplete notification indicates that a
One-Way-Delay-Test (OWDT) frame, or a Two-Way-Delay-Test (TWDT) response
was received. For an OWDT frame, traps are raised only when a delay
threshold of three (3) seconds is exceeded."
::= { tnDot1agNotifications 4 }
tnDot1agCfmMepAisStateChanged NOTIFICATION-TYPE
OBJECTS {
tnDot1agCfmMepEthRxAis
}
STATUS current
DESCRIPTION
"The tnDot1agCfmMepAisStateChanged notification is generated when
a MEP enters or exits an AIS state."
::= { tnDot1agNotifications 5 }
-- tnDot1agCfmMipEvaluation NOTIFICATION-TYPE
-- OBJECTS {
-- tnDot1agCfmNotifySvcId
-- }
-- STATUS current
-- DESCRIPTION
-- "The tnDot1agCfmMipEvaluation notification is generated when a
-- virtual MEP is created or deleted causing MIP reevaluation on the
-- service. On virtual MEP creation, any MIPs in the service will be
-- removed. On virtual MEP deletion, the MIPs are reevaluated."
-- ::= { tnDot1agNotifications 6 }
tnDot1agCfmMepSLMTestComplete NOTIFICATION-TYPE
OBJECTS {
tnDot1agCfmMepSlmTestId,
tnDot1agCfmMepSlmRemoteMepId,
tnDot1agCfmMepSlmLastTxSeqF,
tnDot1agCfmMepSlmPacketIn,
tnDot1agCfmMepSlmPacketLossIn,
tnDot1agCfmMepSlmPacketLossOut,
tnDot1agCfmMepSlmPacketUnack
}
STATUS current
DESCRIPTION
"The tnDot1agCfmMepSLMTestComplete notification is generated when
a two-way Synthetic Loss Measurement (SLM) test is completed."
::= { tnDot1agNotifications 7 }
tnDot1agCfmMepOndemandLmTestComplete NOTIFICATION-TYPE
OBJECTS {
tnDot1agCfmMepOndemandLmTnTF,
tnDot1agCfmMepOndemandLmTnLF,
tnDot1agCfmMepOndemandLmTfTF,
tnDot1agCfmMepOndemandLmTfLF,
tnDot1agCfmMepOndemandLmUnack
}
STATUS current
DESCRIPTION
"The tnDot1agCfmMepOndemandLmTestComplete notification is generated when
a on-demand regular Loss Measurement (LM) test is completed."
::= { tnDot1agNotifications 8 }
--
-- Conformance Information
--
-- tnDot1agCfmCompliances OBJECT IDENTIFIER ::= { tnDot1agMIBConformance 1 }
-- tnDot1agCfmGroups OBJECT IDENTIFIER ::= { tnDot1agMIBConformance 2 }
-- Compliance statements
-- tnDot1agCfmCompliance MODULE-COMPLIANCE
-- STATUS obsolete
-- DESCRIPTION
-- "The compliance statement for revision 1.0 of TIMETRA-IEEE8021-CFM-MIB."
-- MODULE this module
-- MANDATORY-GROUPS {
-- tnDot1agCfmSdpBindStackGroup,
-- tnDot1agCfmMepGroup,
-- tnDot1agCfmSapStackGroup
-- }
-- ::= { tnDot1agCfmCompliances 1 }
-- tnDot1agCfmComplianceV7v0 MODULE-COMPLIANCE
-- STATUS current
-- DESCRIPTION
-- "The compliance statement for revision 7.0 of the 7x50 system"
-- MODULE this module
-- MANDATORY-GROUPS {
-- tnDot1agCfmSdpBindStackGroup,
-- tnDot1agCfmSapStackGroup,
-- tnDot1agCfmNotificationGroup,
-- tmnxY1731CfmNotificationGroup,
-- tnDot1agCfmMipGroup,
-- tnDot1agCfmMipNotifyGroup,
-- tnDot1agCfmMepGroupV7v0
-- }
-- ::= { tnDot1agCfmCompliances 2 }
-- tnDot1agCfmSdpBindStackGroup OBJECT-GROUP
-- OBJECTS {
-- tnDot1agCfmSdpBindStackMdIndex,
-- tnDot1agCfmSdpBindStackMaIndex,
-- tnDot1agCfmSdpBindStackMepId,
-- tnDot1agCfmSdpBindStackMacAddress
-- }
-- STATUS current
-- DESCRIPTION
-- "The group of objects for management of dot1ag Stack Table applicable
-- to implementing SDP-Bindings."
-- ::= { tnDot1agCfmGroups 1 }
-- tnDot1agCfmMepGroup OBJECT-GROUP
-- OBJECTS {
-- tnDot1agCfmMepSdpId,
-- tnDot1agCfmMepVcId,
-- tnDot1agCfmMepMacAddress
-- }
-- STATUS obsolete
-- DESCRIPTION
-- "The group of objects for management of dot1ag MEP Table applicable
-- to implementing SDP-Bindings."
-- ::= { tnDot1agCfmGroups 2 }
-- tnDot1agCfmSapStackGroup OBJECT-GROUP
-- OBJECTS {
-- tnDot1agCfmStackMdIndex,
-- tnDot1agCfmStackMaIndex,
-- tnDot1agCfmStackMepId,
-- tnDot1agCfmStackMacAddress
-- }
-- STATUS current
-- DESCRIPTION
-- "The group of objects for management of dot1ag Stack Table applicable
-- to implementing SAP on the 7x50."
-- ::= { tnDot1agCfmGroups 3 }
-- tnDot1agCfmNotificationGroup NOTIFICATION-GROUP
-- NOTIFICATIONS {
-- tnDot1agCfmMepLbmTestComplete,
-- tnDot1agCfmMepLtmTestComplete
-- }
-- STATUS current
-- DESCRIPTION
-- "The group of objects for management of dot1ag Notifications applicable
-- to implementing CFM on the 7x50."
-- ::= {tnDot1agCfmGroups 4 }
-- tnDot1agCfmMipGroup OBJECT-GROUP
-- OBJECTS {
-- tnDot1agCfmSapMipRowStatus,
-- tnDot1agCfmSdpMipRowStatus
-- }
-- STATUS current
-- DESCRIPTION
-- "The group of objects for management of dot1ag MIP Tables applicable
-- to implementing MIPs."
-- ::= { tnDot1agCfmGroups 5 }
-- tnDot1agCfmMepGroupV7v0 OBJECT-GROUP
-- OBJECTS {
-- tnDot1agCfmMaNetTotalMEPCount,
-- tnDot1agCfmMaMepListMacAddress,
-- tnDot1agCfmMepSdpId,
-- tnDot1agCfmMepVcId,
-- tnDot1agCfmMepMacAddress,
-- tnDot1agCfmMepAisEnable,
-- tnDot1agCfmMepAisMegLevel,
-- tnDot1agCfmMepAisPriority,
-- tnDot1agCfmMepAisInterval,
-- tnDot1agCfmMepEthTestEnable,
-- tnDot1agCfmMepEthTestPattern,
-- tnDot1agCfmMepEthRxAisInterval,
-- tnDot1agCfmMepEthRxAis,
-- tnDot1agCfmMepEthAisTxCount,
-- tnDot1agCfmMepEthTestMacAddr,
-- tnDot1agCfmMepEthTestDataLen,
-- tnDot1agCfmMepEthTestPriority,
-- tnDot1agCfmMepOWDTMacAddress,
-- tnDot1agCfmMepOWDTPriority,
-- tnDot1agCfmMepTWDTMacAddress,
-- tnDot1agCfmMepTWDTPriority,
-- tnDot1agCfmMepFrameCount,
-- tnDot1agCfmMepByteCount,
-- tnDot1agCfmMepFailedBits,
-- tnDot1agCfmMepCrcFailures,
-- tnDot1agCfmMepCurrByteCount,
-- tnDot1agCfmMepCurrFailedBits,
-- tnDot1agCfmMepCurrCrcFailures,
-- tnDot1agCfmMepDelayTestDelay,
-- tnDot1agCfmMepDelayVariation,
-- tnDot1agCfmMepDelayNearEndTestDelay,
-- tnDot1agCfmMepDelayNearEndVariation,
-- tnDot1agCfmMepDelayFarEndTestDelay,
-- tnDot1agCfmMepDelayFarEndVariation,
-- tnDot1agCfmMepCsfInterval
-- tnDot1agCfmMepCsfDirection
-- tnDot1agCfmMepCsfPriority
-- tnDot1agCfmMepSvcId,
-- tnDot1agCfmMepControlMep,
-- tnDot1agCfmMepEthTestThreshold,
-- tnDot1agCfmMepOWDTThreshold,
-- tnDot1agCfmVStackMdIndex,
-- tnDot1agCfmVStackMaIndex,
-- tnDot1agCfmVStackMepId,
-- tnDot1agCfmVStackMacAddress,
-- tnDot1agCfmStackMPType,
-- tnDot1agCfmMepType,
-- tnDot1agCfmMepFaultPropagation,
-- tnDot1agCfmMepOWDTDataSize
-- }
-- STATUS current
-- DESCRIPTION
-- "The group of objects for management dot1ag and Y.1731 tables applicable
-- to implementing Virtual MEPs and MEGs on the 7x50, and enabling APS
-- support."
-- ::= { tnDot1agCfmGroups 6 }
-- tmnxY1731CfmNotificationGroup NOTIFICATION-GROUP
-- NOTIFICATIONS {
-- tnDot1agCfmMepEthTestComplete,
-- tnDot1agCfmMepDMTestComplete,
-- tnDot1agCfmMepAisStateChanged
-- }
-- STATUS current
-- DESCRIPTION
-- "The group of objects for management of Y.1731 Notifications applicable
-- to implementing CFM on the 7x50."
-- ::= {tnDot1agCfmGroups 7 }
-- tnDot1agCfmNotifyObjsGroup OBJECT-GROUP
-- OBJECTS {
-- tnDot1agCfmNotifySvcId
-- }
-- STATUS current
-- DESCRIPTION
-- "The group of objects supporting notifications for revision 7.0 on
-- Nokia 7x50 SR series systems."
-- ::= { tnDot1agCfmGroups 8 }
-- tnDot1agCfmMipNotifyGroup NOTIFICATION-GROUP
-- NOTIFICATIONS {
-- tnDot1agCfmMipEvaluation
-- }
-- STATUS current
-- DESCRIPTION
-- "The group of notification objects for management of dot1ag MIPs."
-- ::= { tnDot1agCfmGroups 9 }
--tnDot1agCfmV9v0Groups OBJECT IDENTIFIER ::= { tnDot1agCfmGroups 13 }
--tnDot1agCfmMepSlmGroupV9v0 OBJECT-GROUP
-- OBJECTS {
-- tnDot1agCfmSLMInactivityTimer,
-- tnDot1agCfmMepSlmTWTestStatus,
-- tnDot1agCfmMepSlmTWTestId,
-- tnDot1agCfmMepSlmTWMacAddress,
-- tnDot1agCfmMepSlmTWPriority,
-- tnDot1agCfmMepSlmTWInterval,
-- tnDot1agCfmMepSlmTWTimeout,
-- tnDot1agCfmMepSlmTWDataSize,
-- tnDot1agCfmMepSlmTWSendCount,
-- tnDot1agCfmMepSlmTWIntervalRedef,
-- tnDot1agCfmMepSlmTWIntrvlUnits,
-- tnDot1agCfmMepSlmOWTestStatus,
-- tnDot1agCfmCompName,
-- tnDot1agCfmCompResourceUsage,
-- tnDot1agCfmCompResourceLimit,
-- tnDot1agCfmMepSlmOWTestId,
-- tnDot1agCfmMepSlmOWMacAddress,
-- tnDot1agCfmMepSlmOWPriority,
-- tnDot1agCfmMepSlmOWInterval,
-- tnDot1agCfmMepSlmOWDataSize,
-- tnDot1agCfmMepSlmOWSendCount,
-- tnDot1agCfmMepSlmTestId,
-- tnDot1agCfmMepSlmRemoteMepId,
-- tnDot1agCfmMepSlmLastTxSeqF,
-- tnDot1agCfmMepSlmPacketIn,
-- tnDot1agCfmMepSlmPacketLossIn,
-- tnDot1agCfmMepSlmPacketLossOut,
-- tnDot1agCfmMepSlmPacketUnack,
-- tnDot1agCfmMepOndemandLmTestStatus,
-- tnDot1agCfmMepOndemandLmDestMacAddress,
-- tnDot1agCfmMepOndemandLmPriority,
-- tnDot1agCfmMepOndemandLmInterval,
-- tnDot1agCfmMepOndemandLmSendCount,
-- tnDot1agCfmMepOndemandLmTnTF,
-- tnDot1agCfmMepOndemandLmTnLF,
-- tnDot1agCfmMepOndemandLmTfTF,
-- tnDot1agCfmMepOndemandLmTfLF,
-- tnDot1agCfmMepOndemandLmUnack,
-- tnDot1agCfmMepOWDelayRsltExtTnFD,
-- tnDot1agCfmMepOWDelayRsltExtTnFDV
-- }
-- STATUS current
-- DESCRIPTION
-- "The group of objects for management of Synthetic Loss Measurement Tests
-- for the SROS release 9.0."
-- ::= { tnDot1agCfmV9v0Groups 4 }
END