218 lines
5.9 KiB
Plaintext
218 lines
5.9 KiB
Plaintext
NEWTEC-REDUNDANCY-MIB DEFINITIONS ::= BEGIN
|
|
|
|
IMPORTS
|
|
Unsigned32,
|
|
MODULE-IDENTITY,
|
|
OBJECT-IDENTITY,
|
|
OBJECT-TYPE
|
|
FROM SNMPv2-SMI
|
|
|
|
MODULE-COMPLIANCE,
|
|
OBJECT-GROUP
|
|
FROM SNMPv2-CONF
|
|
|
|
NtcEnable
|
|
FROM NEWTEC-TC-MIB
|
|
|
|
DisplayString
|
|
FROM SNMPv2-TC
|
|
|
|
ntcFunction
|
|
FROM NEWTEC-MAIN-MIB;
|
|
|
|
|
|
--
|
|
-- Module Identification
|
|
--
|
|
|
|
ntcRedundancy MODULE-IDENTITY
|
|
LAST-UPDATED "201801161000Z"
|
|
ORGANIZATION "Newtec Cy"
|
|
CONTACT-INFO
|
|
"Newtec Cy
|
|
Postal: Newtec Cy
|
|
Laarstraat 5
|
|
B-9100 Sint-Niklaas
|
|
Belgium
|
|
|
|
Tel: +32 3 780 65 00
|
|
Fax: +32 3 780 65 49
|
|
Web: www.newtec.be
|
|
E-mail: techsupport@newtec.be"
|
|
DESCRIPTION
|
|
"Newtec modular MIB containing definitions for redundancy functionality."
|
|
|
|
REVISION "201801161000Z"
|
|
DESCRIPTION
|
|
"ntcRedunMonitoring and ntcRedunType added"
|
|
REVISION "201301081200Z"
|
|
DESCRIPTION
|
|
"Release for MDM6000 and NOP1760 R1.0"
|
|
REVISION "201206281200Z"
|
|
DESCRIPTION
|
|
"Release for M6100 R1.2"
|
|
::= { ntcFunction 1800 }
|
|
|
|
|
|
--
|
|
-- Top-Level Structure
|
|
--
|
|
|
|
-- ntcRedundancy content
|
|
|
|
ntcRedunObjects OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION "Container holding ntcRedunObjects definitions."
|
|
::= { ntcRedundancy 1 }
|
|
|
|
ntcRedunConformance OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION "Conformance requirements."
|
|
::= { ntcRedundancy 2 }
|
|
|
|
-- ntcRedunConformance content
|
|
|
|
ntcRedunConfCompliance OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION "Device compliance statements."
|
|
::= { ntcRedunConformance 1 }
|
|
|
|
ntcRedunConfGroup OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION "Groups used by device compliance statements."
|
|
::= { ntcRedunConformance 2 }
|
|
|
|
|
|
--
|
|
-- Managed Objects
|
|
--
|
|
|
|
ntcRedunEnable OBJECT-TYPE
|
|
SYNTAX NtcEnable
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Enable or disable Device Redundancy."
|
|
DEFVAL { off }
|
|
::= { ntcRedunObjects 1 }
|
|
|
|
ntcRedunInitialState OBJECT-TYPE
|
|
SYNTAX INTEGER { standby(0), active(1) }
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Initial Device Redundancy State when Device Redundancy is enabled. In Standby
|
|
state the modulator output will be disabled."
|
|
DEFVAL { standby }
|
|
::= { ntcRedunObjects 2 }
|
|
|
|
ntcRedunOperationalState OBJECT-TYPE
|
|
SYNTAX INTEGER { active(0), standby(1), na(2) }
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Displays the operational device redundancy state. It is only relevant when
|
|
device redundancy is enabled."
|
|
::= { ntcRedunObjects 3 }
|
|
|
|
ntcRedunType OBJECT-TYPE
|
|
SYNTAX INTEGER { unit(0), carrier(1) }
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Defines the type of redundancy to support which can be either for the full
|
|
device (unit) or a partial part of the device (carrier)."
|
|
DEFVAL { unit }
|
|
::= { ntcRedunObjects 4 }
|
|
|
|
ntcRedunMonitoringTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF NtcRedunMonitoringEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Monitoring table"
|
|
::= { ntcRedunObjects 5 }
|
|
|
|
ntcRedunMonitoringEntry OBJECT-TYPE
|
|
SYNTAX NtcRedunMonitoringEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A conceptual row of the ntcRedunMonitoringTable."
|
|
INDEX { ntcRedunMonitoringName }
|
|
::= { ntcRedunMonitoringTable 1 }
|
|
|
|
NtcRedunMonitoringEntry ::= SEQUENCE {
|
|
ntcRedunMonitoringName Unsigned32,
|
|
ntcRedunCarrType DisplayString,
|
|
ntcRedunCarrName DisplayString,
|
|
ntcRedunOpState INTEGER
|
|
}
|
|
|
|
ntcRedunMonitoringName OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The index of the row"
|
|
::= { ntcRedunMonitoringEntry 1 }
|
|
|
|
ntcRedunCarrType OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..32))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This defines the type where the Carrier Id is derived from."
|
|
::= { ntcRedunMonitoringEntry 2 }
|
|
|
|
ntcRedunCarrName OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..32))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This defines the name where the Carrier Id is derived from."
|
|
::= { ntcRedunMonitoringEntry 3 }
|
|
|
|
ntcRedunOpState OBJECT-TYPE
|
|
SYNTAX INTEGER { active(0), standby(1), na(2) }
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Displays the operational device redundancy state. It is only relevant when
|
|
device redundancy is enabled."
|
|
::= { ntcRedunMonitoringEntry 4 }
|
|
|
|
|
|
--
|
|
-- Module Conformance
|
|
--
|
|
|
|
ntcRedunConfGrpV1Standard OBJECT-GROUP
|
|
OBJECTS {
|
|
ntcRedunEnable,
|
|
ntcRedunInitialState,
|
|
ntcRedunOperationalState,
|
|
ntcRedunType,
|
|
ntcRedunCarrType,
|
|
ntcRedunCarrName,
|
|
ntcRedunOpState
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Managed objects that constitute version 1 of a system device with standard capabilities."
|
|
::= { ntcRedunConfGroup 1}
|
|
|
|
ntcRedunConfCompV1Standard MODULE-COMPLIANCE
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Compliance statement for Newtec device MIB implementations."
|
|
MODULE -- this module
|
|
MANDATORY-GROUPS
|
|
{
|
|
ntcRedunConfGrpV1Standard
|
|
}
|
|
::= { ntcRedunConfCompliance 1 }
|
|
|
|
|
|
END
|