3871 lines
107 KiB
Plaintext

NATEKS-MIB DEFINITIONS ::= BEGIN
IMPORTS
MODULE-IDENTITY, OBJECT-TYPE, NOTIFICATION-TYPE, enterprises,
Gauge32, Integer32, IpAddress, TimeTicks
FROM SNMPv2-SMI
OBJECT-GROUP, NOTIFICATION-GROUP, MODULE-COMPLIANCE
FROM SNMPv2-CONF
TEXTUAL-CONVENTION, DisplayString, DateAndTime, MacAddress
FROM SNMPv2-TC
ifDescr
FROM RFC1213-MIB
InterfaceIndex
FROM IF-MIB;
nateks MODULE-IDENTITY
LAST-UPDATED "201611221200Z"
ORGANIZATION "Nateks Group"
CONTACT-INFO
" Vladimir Gudin
Postal: 10A, Vesyolaya str.
Moscow, 115516
Russian Federation
Tel: +7 499 704 32 32
E-mail: gudin@nateks.ru"
DESCRIPTION
"Added statReset to stats branch"
REVISION "201611221200Z"
DESCRIPTION
"Added sfpDDMIfIndex to SfpDDMEntry"
REVISION "201609151200Z"
DESCRIPTION
"This MIB module defines variables and variable groups common
to more than one type of equipment manufactured by Nateks Group."
REVISION "201601211200Z"
DESCRIPTION
"Added sfpDDMmediaType sfpDDMpresence fields to SfpDDMEntry"
REVISION "201601201200Z"
DESCRIPTION
"Added Digital IO traps and compliance statements"
REVISION "201503101200Z"
DESCRIPTION
"Added Digital IO support"
REVISION "201411171200Z"
DESCRIPTION
"Added SFP DDM support"
REVISION "201411131200Z"
DESCRIPTION
"Added support for FTP operations"
REVISION "201404161200Z"
DESCRIPTION
"Converted from SMIv1 version of NATEKS-MIB v1.2."
::= { enterprises 4249 }
nateksTraps OBJECT IDENTIFIER ::= { nateks 0 }
nateksProducts OBJECT IDENTIFIER ::= { nateks 1 }
megatrans3CLTU OBJECT IDENTIFIER ::= { nateksProducts 1 }
orion2LTU OBJECT IDENTIFIER ::= { nateksProducts 7 }
megatrans3CRGN OBJECT IDENTIFIER ::= { nateksProducts 8 }
megatrans4LTU OBJECT IDENTIFIER ::= { nateksProducts 11 }
megatrans4RGN OBJECT IDENTIFIER ::= { nateksProducts 12 }
orion3LTU OBJECT IDENTIFIER ::= { nateksProducts 22 }
orion3NTU OBJECT IDENTIFIER ::= { nateksProducts 23 }
orion3repeater OBJECT IDENTIFIER ::= { nateksProducts 24 }
miniFlex OBJECT IDENTIFIER ::= { nateksProducts 26 }
nateksMgmt OBJECT IDENTIFIER ::= { nateks 2 }
common OBJECT IDENTIFIER ::= { nateksMgmt 3 }
config OBJECT IDENTIFIER ::= { nateksMgmt 4 }
configSystem OBJECT IDENTIFIER ::= { config 100 }
stats OBJECT IDENTIFIER ::= { nateksMgmt 5 }
g826 OBJECT IDENTIFIER ::= { stats 1 }
alarms OBJECT IDENTIFIER ::= { stats 2 }
tlm OBJECT IDENTIFIER ::= { stats 3 }
dsl OBJECT IDENTIFIER ::= { stats 4 }
indication OBJECT IDENTIFIER ::= { stats 5 }
temperature OBJECT IDENTIFIER ::= { stats 6 }
time OBJECT IDENTIFIER ::= { stats 7 }
localPower OBJECT IDENTIFIER ::= { stats 8 }
sfpDDM OBJECT IDENTIFIER ::= { stats 9 }
io OBJECT IDENTIFIER ::= { stats 10 }
ioDIn OBJECT IDENTIFIER ::= { io 1}
ioDOut OBJECT IDENTIFIER ::= { io 2}
maintenance OBJECT IDENTIFIER ::= { nateksMgmt 6 }
tftp OBJECT IDENTIFIER ::= { maintenance 1 }
nateksSecurity OBJECT IDENTIFIER ::= { nateksMgmt 7 }
macFilter OBJECT IDENTIFIER ::= { nateksSecurity 1 }
nateksDev OBJECT IDENTIFIER ::= { nateksMgmt 8 }
nateksMibInfo OBJECT IDENTIFIER ::= { nateks 3 }
nateksMIBGroup OBJECT IDENTIFIER ::= { nateksMibInfo 1 }
nateksMIBCompliance OBJECT IDENTIFIER ::= { nateksMibInfo 2 }
IntegerNumber ::= TEXTUAL-CONVENTION
DISPLAY-HINT "d"
STATUS current
DESCRIPTION
"Number of some objects, for example, rows in the table. May
be zero, if there are no objects or higher if there are some."
SYNTAX Integer32 (0..2147483647)
IntegerIndex ::= TEXTUAL-CONVENTION
DISPLAY-HINT "d"
STATUS current
DESCRIPTION
"One-based index to the table."
SYNTAX Integer32 (1..2147483647)
IntegerWithDecimal ::= TEXTUAL-CONVENTION
DISPLAY-HINT "d-1"
STATUS current
DESCRIPTION "Fixed-point value with one decimal digit. For example, 250 = 25, -105 = -10.5."
SYNTAX Integer32
IntegerMillis ::= TEXTUAL-CONVENTION
DISPLAY-HINT "d-3"
STATUS current
DESCRIPTION "Fixed-point value with three decimal digits. For example, 25000 = 25, -10500 = -10.5."
SYNTAX Integer32
systemAlarm OBJECT-TYPE
SYNTAX INTEGER {
no(1),
nonurgent(2),
urgent(3),
urgentAndNonurgent(4)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Device alarm state"
::= { nateksMgmt 1 }
systemReset OBJECT-TYPE
SYNTAX INTEGER {
reset(1),
readValue(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Writing reset(1) to maintReset perform a restart of the device.
Read always returns readValue(2)."
::= { nateksMgmt 2 }
--- common group
model OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Model name, for example MGS-3C-RGN. It is mandatory
that this only contain printable ASCII characters."
::= { common 1 }
id OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Device ID, displayed in the main menu of the module. It is mandatory
that this only contain printable ASCII characters."
::= { common 2 }
hardwareVersion OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Version of the device's hardware. For examle: 1.0"
::= { common 3 }
softwareVersion OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Version of the device's main software and, optionally, versions
of firmware loaded in DSL chipsets, etc. (if present).
For examle: 3.5.0.5.9/5.0"
::= { common 4 }
softwareDate OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..10))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Build date of the device's main software in MM.DD.YYYY format.
Empty string, if build date is not maintained by devices software."
::= { common 5 }
moduleType OBJECT-TYPE
SYNTAX INTEGER {
subrack(1),
standalone(2),
standaloneSmall(3),
rackmount(4),
miniflex(5)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Module type"
::= { common 6 }
subrackAddress OBJECT-TYPE
SYNTAX Integer32 (0..128)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Address of the module in the FlexGain cassette. For modules that
do not have such an address, a value of 0 is returned."
::= { common 7 }
errorCode OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Device-dependent error code. Normal value for errorCode is 0,
i.e. device is fully operational. Any non-zero value indicates
device hardware fault to management software."
::= { common 8 }
serialNumber OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Device serial number."
::= { common 9 }
--- config group
configRW OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..65535))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Reading configRW results in reading the whole running config
(as DUMP R in Megatrans 3C does). Writing configRW results
in writing to startup config (as LOAD in Megatrans 3C does).
This variable may be also used by devices, that do not maintain
configValueTable and configGroupTable, to get/set their
configuration."
::= { config 1 }
configDefault OBJECT-TYPE
SYNTAX IntegerNumber
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Writing integer value to configDefault applies
default profile to the configuration. Values and contents
of default profiles are device-dependent."
::= { config 2 }
--- config-system group. Is used for configure and read configuration
--- of Megatrans-3C, 4, 4W, Orion2, Orion3 line of devices.
configNumberValues OBJECT-TYPE
SYNTAX IntegerNumber
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of configuration values in device's configuration."
::= { configSystem 1 }
configValueTable OBJECT-TYPE
SYNTAX SEQUENCE OF ConfigValueEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A list of configuration values. The number of
entries is given by the value of configSize."
::= { configSystem 2 }
configValueEntry OBJECT-TYPE
SYNTAX ConfigValueEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Configuration item."
INDEX { valueId }
::= { configValueTable 1 }
ConfigValueEntry ::=
SEQUENCE {
valueId
IntegerIndex,
valueGroup
IntegerIndex,
valueName
DisplayString,
valueGroupName
DisplayString,
valueType
INTEGER,
valueStatus
INTEGER,
valueStartup
OCTET STRING,
valueRunning
OCTET STRING,
valueNew
OCTET STRING,
valueBackup
OCTET STRING
}
valueId OBJECT-TYPE
SYNTAX IntegerIndex (1..2147483647)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A unique index of configuration value. It is constant
at least until main software of the module changes."
::= { configValueEntry 1 }
valueGroup OBJECT-TYPE
SYNTAX IntegerIndex
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Index of values' configuration group in the configGroupTable."
::= { configValueEntry 2 }
valueName OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A unique name of configuration value. It is constant
at least until main software of the module changes. Usually,
it remains constant through the lifecycle of the product."
::= { configValueEntry 3 }
valueGroupName OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Name of values' configuration group."
::= { configValueEntry 4 }
valueType OBJECT-TYPE
SYNTAX INTEGER {
setNow(1),
applyConfirm(2),
afterReset(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Value type."
::= { configValueEntry 5 }
valueStatus OBJECT-TYPE
SYNTAX INTEGER {
unchanged(1),
changed(2),
applied(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Change status for a value.
All values of valueType setNow(1) have unchanged(1) status.
Status for values of valueType applyConfirm(2):
Initially, all values have unchanged(1) status.
When value is changed in new configuration, valueStatus is
changed(2). When APPLY is made in respect of a value,
valueStatus is applied(3). When CONFIRM is made for a value,
valueStatus returns to unchanged(1).
Status for values of type afterReset:
If valueStartup is different from valueRunning, valueStatus
is changed(2), otherwise unchanged(1)."
::= { configValueEntry 6 }
valueStartup OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..65535))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Startup value of configuration variable. Write operation changes
valueStartup for values of valueType afterReset(3),
valueRunning for values of valueType setNow(1),
valueNew for values of valueType applyConfirm(2)."
::= { configValueEntry 7 }
valueRunning OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..65535))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Running value of configuration variable. Write operation changes
valueStartup for values of valueType afterReset(3),
valueRunning for values of valueType setNow(1),
valueNew for values of valueType applyConfirm(2)."
::= { configValueEntry 8 }
valueNew OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..65535))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"New value of configuration variable. Write operation changes
valueStartup for values of valueType afterReset(3),
valueRunning for values of valueType setNow(1),
valueNew for values of valueType applyConfirm(2)."
::= { configValueEntry 9 }
valueBackup OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..65535))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Backup value of configuration variable."
::= { configValueEntry 10 }
configNumberGroups OBJECT-TYPE
SYNTAX IntegerNumber
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of configuration groups in device's configuration."
::= { configSystem 3 }
configGroupTable OBJECT-TYPE
SYNTAX SEQUENCE OF ConfigGroupEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A list of configuration values. The number of
entries is given by the value of configSize."
::= { configSystem 4 }
configGroupEntry OBJECT-TYPE
SYNTAX ConfigGroupEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Configuration group."
INDEX { groupId }
::= { configGroupTable 1 }
ConfigGroupEntry ::=
SEQUENCE {
groupId
IntegerIndex,
groupName
DisplayString,
groupType
INTEGER,
groupStatus
INTEGER
}
groupId OBJECT-TYPE
SYNTAX IntegerIndex (1..2147483647)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A unique index of configuration group. It is constant
at least until main software of the module changes."
::= { configGroupEntry 1 }
groupName OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Name of configuration group. It is constant
at least until main software of the module changes. Usually,
it remains constant through the lifecycle of the product."
::= { configGroupEntry 2 }
groupType OBJECT-TYPE
SYNTAX INTEGER {
setNow(1),
applyConfirm(2),
afterReset(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Group type."
::= { configGroupEntry 3 }
groupStatus OBJECT-TYPE
SYNTAX INTEGER {
unchanged(1),
changed(2),
applied(3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Change status for a groupvalue.
All groups of groupType setNow(1) have unchanged(1) status.
Status for groups of groupType applyConfirm(2):
Initially, all values have unchanged(1) status.
When some of group values are changed in new configuration,
groupStatus is changed(2). When APPLY is made for a group,
groupStatus is applied(3). When CONFIRM is made for a group,
groupStatus returns to unchanged(1).
Status for groups of type afterReset:
If startup values in the group are different from running
values, groupStatus is changed(2), otherwise unchanged(1).
Writing applied(3) to the groupStatus makes APPLY operation
on a group. APPLY operation is allowed only for groups of
groupType applyConfirm(2).
Other write operations should report error."
::= { configGroupEntry 4 }
configApplyAll OBJECT-TYPE
SYNTAX INTEGER {
applyAll(1),
readValue(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Writing applyAll(1) to configApplyAll makes APPLY ALL operation.
Read always returns readValue(2)."
::= { configSystem 5 }
configConfirm OBJECT-TYPE
SYNTAX INTEGER {
confirm(1),
readValue(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Writing confirm(1) to configConfirm makes CONFIRM operation.
Read always returns readValue(2)."
::= { configSystem 6 }
configBackup OBJECT-TYPE
SYNTAX INTEGER {
backup(1),
readValue(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Writing backup(1) to configBackup performs BACKUP operation.
Read always returns readValue(2)."
::= { configSystem 7 }
configRestore OBJECT-TYPE
SYNTAX INTEGER {
restore(1),
readValue(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Writing restore(1) to configRestore performs RESTORE operation.
Read always returns readValue(2)."
::= { configSystem 8 }
--- stats group
--- g826 group
g826Number OBJECT-TYPE
SYNTAX IntegerNumber
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of g826 statistics."
::= { g826 1 }
g826Table OBJECT-TYPE
SYNTAX SEQUENCE OF G826Entry
MAX-ACCESS not-accessible
STATUS deprecated
DESCRIPTION
"A list of g826 statistics. Each consists of an interface index
in interfaces table, statistics name and g826 statistics valuess."
::= { g826 2 }
g826Entry OBJECT-TYPE
SYNTAX G826Entry
MAX-ACCESS not-accessible
STATUS deprecated
DESCRIPTION
"G826 statistics."
INDEX { g826Id }
::= { g826Table 1 }
G826Entry ::=
SEQUENCE {
g826Id
IntegerIndex,
g826IfIndex
InterfaceIndex,
g826Name
DisplayString,
g826EB
Gauge32,
g826ES
Gauge32,
g826SES
Gauge32,
g826BBE
Gauge32,
g826AvailableTime
Gauge32,
g826UnavailableTime
Gauge32,
g826StatReset
INTEGER
}
g826Id OBJECT-TYPE
SYNTAX IntegerIndex (1..2147483647)
MAX-ACCESS not-accessible
STATUS deprecated
DESCRIPTION
"A unique index of this g826 statistics. It is constant
at least between device reboots."
::= { g826Entry 1 }
g826IfIndex OBJECT-TYPE
SYNTAX InterfaceIndex
MAX-ACCESS read-only
STATUS deprecated
DESCRIPTION
"Index of interface in interfaces table, this g826
statistics is for."
::= { g826Entry 2 }
g826Name OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS deprecated
DESCRIPTION
"Name of the statistic, for example: E1-1-CRC4, E1-2-E-Bit."
::= { g826Entry 3 }
g826EB OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS deprecated
DESCRIPTION
"Number of errored blocks."
::= { g826Entry 4 }
g826ES OBJECT-TYPE
SYNTAX Gauge32
UNITS "s"
MAX-ACCESS read-only
STATUS deprecated
DESCRIPTION
"Number of errored seconds."
::= { g826Entry 5 }
g826SES OBJECT-TYPE
SYNTAX Gauge32
UNITS "s"
MAX-ACCESS read-only
STATUS deprecated
DESCRIPTION
"Number of severely errored seconds."
::= { g826Entry 6 }
g826BBE OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS deprecated
DESCRIPTION
"Number of background block errors."
::= { g826Entry 7 }
g826AvailableTime OBJECT-TYPE
SYNTAX Gauge32
UNITS "s"
MAX-ACCESS read-only
STATUS deprecated
DESCRIPTION
"Available time in seconds."
::= { g826Entry 8 }
g826UnavailableTime OBJECT-TYPE
SYNTAX Gauge32
UNITS "s"
MAX-ACCESS read-only
STATUS deprecated
DESCRIPTION
"Unavailable time in seconds."
::= { g826Entry 9 }
g826StatReset OBJECT-TYPE
SYNTAX INTEGER {
reset(1),
readValue(2)
}
MAX-ACCESS read-write
STATUS deprecated
DESCRIPTION
"Writing reset(1) to g826StatReset restarts this g826 statistic.
Read always returns readValue(2)."
::= { g826Entry 10 }
g826Reset OBJECT-TYPE
SYNTAX INTEGER {
reset(1),
readValue(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Writing reset(1) to g826Reset restarts all g826 statistics.
Read always returns readValue(2)."
::= { g826 3 }
-- NATEKS-MIB v0.9 and earlier versions contained a typo: g826Reset
-- was called g286Reset. This string maintains backward compatibility.
-- g286Reset OBJECT IDENTIFIER ::= { g826 3 }
ifG826Table OBJECT-TYPE
SYNTAX SEQUENCE OF IfG826Entry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A list of g826 statistics. Each consists of an interface index
in interfaces table, statistics name and g826 statistics valuess."
::= { g826 4 }
ifG826Entry OBJECT-TYPE
SYNTAX IfG826Entry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"G826 statistics grouped by interface."
INDEX { ifG826IfIndex, ifG826Id }
::= { ifG826Table 1 }
IfG826Entry ::=
SEQUENCE {
ifG826Id
IntegerIndex,
ifG826IfIndex
InterfaceIndex,
ifG826Name
DisplayString,
ifG826EB
Gauge32,
ifG826ES
Gauge32,
ifG826SES
Gauge32,
ifG826BBE
Gauge32,
ifG826AvailableTime
Gauge32,
ifG826UnavailableTime
Gauge32,
ifG826StatReset
INTEGER
}
ifG826Id OBJECT-TYPE
SYNTAX IntegerIndex (1..2147483647)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A unique index of this g826 statistics. It is constant
at least between device reboots."
::= { ifG826Entry 1 }
ifG826IfIndex OBJECT-TYPE
SYNTAX InterfaceIndex(1..2147483647)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Index of interface in interfaces table, this g826
statistics is for."
::= { ifG826Entry 2 }
ifG826Name OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Name of the statistic, for example: E1-1-CRC4, E1-2-E-Bit."
::= { ifG826Entry 3 }
ifG826EB OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of errored blocks."
::= { ifG826Entry 4 }
ifG826ES OBJECT-TYPE
SYNTAX Gauge32
UNITS "s"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of errored seconds."
::= { ifG826Entry 5 }
ifG826SES OBJECT-TYPE
SYNTAX Gauge32
UNITS "s"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of severely errored seconds."
::= { ifG826Entry 6 }
ifG826BBE OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of background block errors."
::= { ifG826Entry 7 }
ifG826AvailableTime OBJECT-TYPE
SYNTAX Gauge32
UNITS "s"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Available time in seconds."
::= { ifG826Entry 8 }
ifG826UnavailableTime OBJECT-TYPE
SYNTAX Gauge32
UNITS "s"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Unavailable time in seconds."
::= { ifG826Entry 9 }
ifG826StatReset OBJECT-TYPE
SYNTAX INTEGER {
reset(1),
readValue(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Writing reset(1) to ifG826StatReset restarts this g826 statistic.
Read always returns readValue(2)."
::= { ifG826Entry 10 }
--- alarm group
alarmNumber OBJECT-TYPE
SYNTAX IntegerNumber
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of alarms."
::= { alarms 1 }
alarmTable OBJECT-TYPE
SYNTAX SEQUENCE OF AlarmEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A list of alarms. Each consists of an interface index
in interfaces table, alarm name, value and cutoff information."
::= { alarms 2 }
alarmEntry OBJECT-TYPE
SYNTAX AlarmEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Alarms."
INDEX { alarmId }
::= { alarmTable 1 }
AlarmEntry ::=
SEQUENCE {
alarmId
IntegerIndex,
alarmIfIndex
InterfaceIndex,
alarmName
DisplayString,
alarmValue
INTEGER,
alarmCutoff
INTEGER,
alarmType
BITS,
alarmDisplayType
INTEGER
}
alarmId OBJECT-TYPE
SYNTAX IntegerIndex (1..2147483647)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A unique index of alarm. It is constant
at least between device reboots."
::= { alarmEntry 1 }
alarmIfIndex OBJECT-TYPE
SYNTAX InterfaceIndex
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Index of interface in interfaces table, which state this
alarm indicates. Alarms, that do not have associated interfaces
(for example, maintenance alarms), should have index
of management interface as alarmIfIndex."
::= { alarmEntry 2 }
alarmName OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Name of the alarm, for example: LOS-S, BER-H."
::= { alarmEntry 3 }
alarmValue OBJECT-TYPE
SYNTAX INTEGER {
on(1),
off(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Alarm status."
::= { alarmEntry 4 }
alarmCutoff OBJECT-TYPE
SYNTAX INTEGER {
on(1),
off(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Alarm cutoff status."
::= { alarmEntry 5 }
alarmType OBJECT-TYPE
SYNTAX BITS {
localMajor(0),
localMinor(1),
remoteMajor(2),
remoteMinor(3),
maintenance(4)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Alarm type. If none of alarm types is applicable to this
alarm, all bits are zero."
::= { alarmEntry 6 }
alarmDisplayType OBJECT-TYPE
SYNTAX INTEGER {
major(1),
minor(2),
maintenance(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Simplified alarm type to be used in trap filters"
::= { alarmEntry 7 }
alarmTrapEnable OBJECT-TYPE
SYNTAX INTEGER {
true(1),
false(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Alarm trap generation setup: changes in alarm state will cause trap
generation when the alarmTrapEnable is true."
::= { alarms 3 }
--- same alarms, but grouped by interface
ifAlarmTable OBJECT-TYPE
SYNTAX SEQUENCE OF IfAlarmEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A two-dimentional array of alarms. Alarms are grouped by interface number."
::= { alarms 4 }
ifAlarmEntry OBJECT-TYPE
SYNTAX IfAlarmEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Alarms grouped by interface."
INDEX { ifAlarmIfIndex, ifAlarmId }
::= { ifAlarmTable 1 }
IfAlarmEntry ::=
SEQUENCE {
ifAlarmId
IntegerIndex,
ifAlarmIfIndex
InterfaceIndex,
ifAlarmName
DisplayString,
ifAlarmValue
INTEGER,
ifAlarmCutoff
INTEGER,
ifAlarmType
BITS,
ifAlarmDisplayType
INTEGER
}
ifAlarmId OBJECT-TYPE
SYNTAX IntegerIndex (1..2147483647)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A unique index of alarm within interface. It is constant
at least between device reboots."
::= { ifAlarmEntry 1 }
ifAlarmIfIndex OBJECT-TYPE
SYNTAX InterfaceIndex (1..2147483647)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Index of interface in interfaces table, which state this
alarm indicates. Alarms, that do not have associated interfaces
(for example, maintenance alarms), should have index
of management interface as alarmIfIndex."
::= { ifAlarmEntry 2 }
ifAlarmName OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Name of the alarm, for example: LOS-S, BER-H."
::= { ifAlarmEntry 3 }
ifAlarmValue OBJECT-TYPE
SYNTAX INTEGER {
on(1),
off(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Alarm status."
::= { ifAlarmEntry 4 }
ifAlarmCutoff OBJECT-TYPE
SYNTAX INTEGER {
on(1),
off(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Alarm cutoff status."
::= { ifAlarmEntry 5 }
ifAlarmType OBJECT-TYPE
SYNTAX BITS {
localMajor(0),
localMinor(1),
remoteMajor(2),
remoteMinor(3),
maintenance(4)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Alarm type. If none of alarm types is applicable to this
alarm, all bits are zero."
::= { ifAlarmEntry 6 }
ifAlarmDisplayType OBJECT-TYPE
SYNTAX INTEGER {
major(1),
minor(2),
maintenance(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Simplified alarm type to be used in trap filters"
::= { ifAlarmEntry 7 }
--- tlm group
tlmNumber OBJECT-TYPE
SYNTAX IntegerNumber
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of tlm contacts."
::= { tlm 1 }
tlmTable OBJECT-TYPE
SYNTAX SEQUENCE OF TlmEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A list of tlms. Each consists of tlm name, setup and status
information, and trap generation setup."
::= { tlm 2 }
tlmEntry OBJECT-TYPE
SYNTAX TlmEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"TLM"
INDEX { tlmId }
::= { tlmTable 1 }
TlmEntry ::=
SEQUENCE {
tlmId
IntegerIndex,
tlmName
DisplayString,
tlmStatus
INTEGER,
tlmLastStatusChange
TimeTicks,
tlmSetup
INTEGER,
tlmTrapEnable
INTEGER
}
tlmId OBJECT-TYPE
SYNTAX IntegerIndex (1..2147483647)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A unique index of TLM. It is constant
at least between device reboots."
::= { tlmEntry 1 }
tlmName OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Name of the TLM."
::= { tlmEntry 2 }
tlmStatus OBJECT-TYPE
SYNTAX INTEGER {
on(1),
off(2),
det(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The status of the TLM: on, off or detected."
::= { tlmEntry 3 }
tlmLastStatusChange OBJECT-TYPE
SYNTAX TimeTicks
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The time of last TLM status change, counted from system start."
::= { tlmEntry 4 }
tlmSetup OBJECT-TYPE
SYNTAX INTEGER {
normalOpen(1),
normalClosed(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"TLM setup: normally open or normally closed.
Writing to this variable will configure this TLM, if the device
does support the write access to this variable."
::= { tlmEntry 5 }
tlmTrapEnable OBJECT-TYPE
SYNTAX INTEGER {
true(1),
false(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"TLM trap generation setup: changes in TLM status will cause trap
generation when the tlmTrapEnable is true."
::= { tlmEntry 6 }
tlmClear OBJECT-TYPE
SYNTAX INTEGER {
reset(1),
readValue(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Writing reset(1) to tlmClear will clear the TLM history,
and det state of all TLM indicators will become off state.
Read always returns readValue(2)."
::= { tlm 3 }
--- dsl group
dslChannelNumber OBJECT-TYPE
SYNTAX IntegerNumber
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of dsl channels."
::= { dsl 1 }
dslUnitType OBJECT-TYPE
SYNTAX INTEGER {
modem(1),
regenerator(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The type of the unit: line termination units (LTU) and
network termination units (NTU) will have the modem(1) value.
All types of regenerators have regenerator(2) value."
::= { dsl 2 }
dslChannelTable OBJECT-TYPE
SYNTAX SEQUENCE OF DslChannelEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A list of DSL channels present on this device. Each consists of DSL index, ifIndex, setup and status
information."
::= { dsl 3 }
dslChannelEntry OBJECT-TYPE
SYNTAX DslChannelEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"DSL channel"
INDEX { dslChannelId }
::= { dslChannelTable 1 }
DslChannelEntry ::=
SEQUENCE {
dslChannelId
IntegerIndex,
dslChannelIfIndex
InterfaceIndex,
dslChannelMode --- Master/Slave
INTEGER,
dslChannelStandard --- G.shdsl, G.shdsl.bis, etc.
INTEGER,
dslChannelClockReference --- 1, 2, 3a, 3b
INTEGER,
dslChannelLineCodeConfig --- PAM configuration
INTEGER,
dslChannelPSDConfig --- Annex configuration
INTEGER,
dslChannelBaserateConfig --- Baserate configuration
Integer32,
dslChannelStatus --- Link up, link down, training
INTEGER,
dslChannelLineCode --- PAM status
INTEGER,
dslChannelPSD --- Annex status
INTEGER,
dslChannelBaserate --- Baserate status
Integer32,
dslChannelLineRate --- Line rate = Baserate*64k + 8k
Integer32,
dslChannelPayloadRate --- Payload rate = Baserate*64k
Integer32,
dslChannelNMR
Integer32,
dslChannelPowerBackoff
Integer32,
dslChannelFarEndPowerBackoff
Integer32,
dslChannelLoopAttenuation
Integer32,
dslChannelEOCNumber
IntegerIndex,
--- For NTU/LTU only
dslChannelRegeneratorNumber
IntegerNumber,
dslChannelRemotePower --- Remote power supply status
INTEGER,
dslChannelRemotePowerVoltage --- Remote power voltage
Integer32
}
dslChannelId OBJECT-TYPE
SYNTAX IntegerIndex (1..2147483647)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A unique index of the DSL channel. It is constant for a given model."
::= { dslChannelEntry 1 }
dslChannelIfIndex OBJECT-TYPE
SYNTAX InterfaceIndex
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Index in interfaces table of this DSL channel."
::= { dslChannelEntry 2 }
dslChannelMode OBJECT-TYPE
SYNTAX INTEGER {
master(1),
slave(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The activation mode of this channel: either it is Master (xU-C) or Slave (xU-R)."
::= { dslChannelEntry 3 }
dslChannelStandard OBJECT-TYPE
SYNTAX INTEGER {
gshdsl(1),
gshdslBis(2),
gshdslExt(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The G.Shdsl mode this channel is working in."
::= { dslChannelEntry 4 }
dslChannelClockReference OBJECT-TYPE
SYNTAX INTEGER {
clockMode1(1),
clockMode2(2),
clockMode3a(3),
clockMode3b(4)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The G.Shdsl clock mode this channel is working in."
::= { dslChannelEntry 5 }
dslChannelLineCodeConfig OBJECT-TYPE
SYNTAX INTEGER {
auto(1),
pam4(2),
pam8(3),
pam16(4),
pam32(5),
pam64(6),
pam128(7)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The configured line code of this channel."
::= { dslChannelEntry 6 }
dslChannelPSDConfig OBJECT-TYPE
SYNTAX INTEGER {
annexA(1),
annexB(2),
annexAB(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The configured PSD mask (annex) of this channel."
::= { dslChannelEntry 7 }
dslChannelBaserateConfig OBJECT-TYPE
SYNTAX Integer32 (0..1024)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The configured base data rate (in 64kbit/s units) of this channel. 0 means auto."
::= { dslChannelEntry 8 }
dslChannelStatus OBJECT-TYPE
SYNTAX INTEGER {
down(1),
preactivation(2),
activation(3),
up(4)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The activation status of this DSL channel."
::= { dslChannelEntry 9 }
dslChannelLineCode OBJECT-TYPE
SYNTAX INTEGER {
notAvailable(0),
pam4(2),
pam8(3),
pam16(4),
pam32(5),
pam64(6),
pam128(7)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Current working line code of this channel. If the link is down, this item
has notAvailable(0) value."
::= { dslChannelEntry 10 }
dslChannelPSD OBJECT-TYPE
SYNTAX INTEGER {
notAvailable(0),
annexA(1),
annexB(2),
annexAB(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Current working PSD mask (annex) of this channel. If the link is down, this item
has notAvailable(0) value."
::= { dslChannelEntry 11 }
dslChannelBaserate OBJECT-TYPE
SYNTAX Integer32(0..1024)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Current working base data rate (in 64kbit/s units) of this channel. If the link is down, this item has 0 value."
::= { dslChannelEntry 12 }
dslChannelLineRate OBJECT-TYPE
SYNTAX Integer32(0..65536)
UNITS "kbps"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Current working line rate in kbit/s of this channel. If the link is down, this item has 0 value."
::= { dslChannelEntry 13 }
dslChannelPayloadRate OBJECT-TYPE
SYNTAX Integer32(0..65536)
UNITS "kbps"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Current working payload rate in kbit/s of this channel. If the link is down, this item has 0 value."
::= { dslChannelEntry 14 }
dslChannelNMR OBJECT-TYPE
SYNTAX Integer32
UNITS "dB"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Current noise margin rate for the DSL channel in dB."
::= { dslChannelEntry 15 }
dslChannelPowerBackoff OBJECT-TYPE
SYNTAX Integer32
UNITS "dB"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Current power backoff of the local side of the DSL channel in dB."
::= { dslChannelEntry 16 }
dslChannelFarEndPowerBackoff OBJECT-TYPE
SYNTAX Integer32
UNITS "dB"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Current far end power backoff of the DSL channel in dB."
::= { dslChannelEntry 17 }
dslChannelLoopAttenuation OBJECT-TYPE
SYNTAX Integer32
UNITS "dB"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Current loop attenuation of the DSL channel in dB."
::= { dslChannelEntry 18 }
dslChannelEOCNumber OBJECT-TYPE
SYNTAX IntegerIndex (1..2147483647)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The EOC number of the unit in this DSL link.
xtuC 1
xtuR 2
repeater N=1..max N+2"
::= { dslChannelEntry 19 }
dslChannelRegeneratorNumber OBJECT-TYPE
SYNTAX IntegerNumber
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of regenerators in the link.
This unit is not present on regenerators."
::= { dslChannelEntry 20 }
dslChannelRemotePower OBJECT-TYPE
SYNTAX INTEGER {
on(1),
off(2),
alarm(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The remote power status of the channel.
This item is not present on regenerators. On devices without remote powering capability it
is present and always shows off(2).
on(1) means the remote power is turned on in configuration and remote power in turned on.
off(2) means the remote power is turned off in configuration or remote power capability is
not present in the device.
alarm(3) means remote power is turned off for a certain amount of time because overcurrent
protection has triggered or AC/DC leakage threshold was met."
::= { dslChannelEntry 21 }
dslChannelRemotePowerVoltage OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Remote power voltage configuration for the channel.
This item is not present on regenerators.
On devices without remote powering capability it is present and always shows 0.
If remote power is turned off for this channel in configuration, 0 is read from this item.
If remote power is turned on for this channel in configuration, remote power nominal voltage
is read from this item regardless of error status (it may be off due to overcurrent etc).
This item appeared in MIB v0.9 and some devices may not support it."
::= { dslChannelEntry 22 }
dslGroupNumber OBJECT-TYPE
SYNTAX IntegerNumber
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of multiwire groups."
::= { dsl 4 }
dslGroupTable OBJECT-TYPE
SYNTAX SEQUENCE OF DslGroupEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table contains information on multipair and 4-wire goups of DSL channels."
::= { dsl 5 }
dslGroupEntry OBJECT-TYPE
SYNTAX DslGroupEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"DSL multipair of 4-wire group"
INDEX { dslGroupId }
::= { dslGroupTable 1 }
DslGroupEntry ::=
SEQUENCE {
dslGroupId
IntegerIndex,
dslGroupType
INTEGER,
dslGroupMainChannel
IntegerIndex,
dslGroupChannel1
IntegerIndex,
dslGroupChannel2
IntegerIndex,
dslGroupChannel3
IntegerIndex,
dslGroupChannel4
IntegerIndex
}
dslGroupId OBJECT-TYPE
SYNTAX IntegerIndex (1..2147483647)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A unique index of the DSL channel group. It is constant between changes of unit configuration."
::= { dslGroupEntry 1 }
dslGroupType OBJECT-TYPE
SYNTAX INTEGER {
type4wire(1),
type2pair(2),
type3pair(3),
type4pair(4)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The type of channel grouping.
type4wire(1) represent 4-wire method of channel aggregation.
type2pair(2)-type4pair(4) represent the M-pair method of channel aggregation."
::= { dslGroupEntry 2 }
dslGroupMainChannel OBJECT-TYPE
SYNTAX IntegerIndex
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This is the dslChannelId of the main channel in the multipair or 4-wire group.
The configuration for all channels in the group is taken from the main channel.
Only the main channel is mentioned in regenerator pairs when regenerator is
working in multipair mode."
::= { dslGroupEntry 3 }
dslGroupChannel1 OBJECT-TYPE
SYNTAX IntegerIndex
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The first channel in the sequence of dslChannelId's of the channels in the
multipair or 4-wire group. The main channel is mentioned amongst others."
::= { dslGroupEntry 4 }
dslGroupChannel2 OBJECT-TYPE
SYNTAX IntegerIndex
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The second channel in the sequence of dslChannelId's of the channels in the
multipair or 4-wire group. The main channel is mentioned amongst others."
::= { dslGroupEntry 5 }
dslGroupChannel3 OBJECT-TYPE
SYNTAX IntegerIndex
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The third channel in the sequence of dslChannelId's of the channels in the
multipair or 4-wire group. The main channel is mentioned amongst others.
Only present for 3-pair and 4-pair groups."
::= { dslGroupEntry 6 }
dslGroupChannel4 OBJECT-TYPE
SYNTAX IntegerIndex
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The fourth channel in the sequence of dslChannelId's of the channels in the
multipair or 4-wire group. The main channel is mentioned amongst others.
Only present for 4-pair groups."
::= { dslGroupEntry 7 }
dslRegenerationChannels OBJECT-TYPE
SYNTAX IntegerNumber
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of regenerator channels working in this device."
::= { dsl 6 }
dslRegenerationTable OBJECT-TYPE
SYNTAX SEQUENCE OF DslRegenerationEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table is a list of regenerator channels working in this device.
Devices that do not have regenerator functions do not need to implement this table."
::= { dsl 7 }
dslRegenerationEntry OBJECT-TYPE
SYNTAX DslRegenerationEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Regeneration channel"
INDEX { dslRegenerationId }
::= { dslRegenerationTable 1 }
DslRegenerationEntry ::=
SEQUENCE {
dslRegenerationId
IntegerIndex,
dslRegenerationSide1
IntegerIndex,
dslRegenerationSide2
IntegerIndex
}
dslRegenerationId OBJECT-TYPE
SYNTAX IntegerIndex (1..2147483647)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A unique index of the DSL regeneration channel. It is constant between configuration changes."
::= { dslRegenerationEntry 1 }
dslRegenerationSide1 OBJECT-TYPE
SYNTAX IntegerIndex
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This is the dslChannelId of side 1 of the regeneration channel."
::= { dslRegenerationEntry 2 }
dslRegenerationSide2 OBJECT-TYPE
SYNTAX IntegerIndex
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This is the dslChannelId of side 2 of the regeneration channel."
::= { dslRegenerationEntry 3 }
--- indication group
indicationLedNumber OBJECT-TYPE
SYNTAX IntegerNumber
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of LED indicators the device has."
::= { indication 1 }
indicationLedTable OBJECT-TYPE
SYNTAX SEQUENCE OF IndicationLedEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A list LED indicators. Each consists of an LED index, textual description,
populated/not populated status, current color and blinking rate."
::= { indication 2 }
indicationLedEntry OBJECT-TYPE
SYNTAX IndicationLedEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"LED inidicators."
INDEX { indicationLedId }
::= { indicationLedTable 1 }
IndicationLedEntry ::=
SEQUENCE {
indicationLedId
IntegerIndex,
indicationLedDescription
DisplayString,
indicationLedState
INTEGER,
indicationLedFlash
INTEGER
}
indicationLedId OBJECT-TYPE
SYNTAX IntegerIndex (1..2147483647)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A unique index of the LED indicator. It is constant between
different models of one device family."
::= { indicationLedEntry 1 }
indicationLedDescription OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Description of LED indicator. May include name on the front/back panel
of the device and/or place of the LED."
::= { indicationLedEntry 2 }
indicationLedState OBJECT-TYPE
SYNTAX INTEGER {
notPopulated(0),
off(1),
red(2),
yellow(3),
green(4),
cyan(5),
blue(6),
magenta(7),
white(8)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The state of a LED. If the LED is not present, it's state is not-populated.
If it is not lit, it's state is OFF. If it is lit, then a color is reported."
::= { indicationLedEntry 3 }
indicationLedFlash OBJECT-TYPE
SYNTAX INTEGER {
notPopulated(0),
blink1000(1),
blink0100(2),
blink1100(3),
blink0010(4),
blink1010(5),
blink0110(6),
blink1110(7),
blink0001(8),
blink1001(9),
blink0101(10),
blink1101(11),
blink0011(12),
blink1011(13),
blink0111(14),
constant(15)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"If the LED is switching on and off at a constant rate, shows how is it blinking.
Values from 1 to 14 represent a bit mask, where each bit shows, if the LED is lit during
corresponding quarter of second: bit 0 - first quarter, bit 1 - second etc.
If the LED is lit constantly, returns 'constant(15)'."
::= { indicationLedEntry 4 }
--- temperature group
temperatureSensorNumber OBJECT-TYPE
SYNTAX IntegerNumber
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of the temperature sensors the device has."
::= { temperature 1 }
temperatureSensorTable OBJECT-TYPE
SYNTAX SEQUENCE OF TemperatureSensorEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A list temperature sensors. First sensor in the list should always
be the sensor that can be considered as 'Board temperature' sensor.
For each sensor there is an identifier, description and the temperature
value in 1/1000 of the Celcium degree."
::= { temperature 2 }
temperatureSensorEntry OBJECT-TYPE
SYNTAX TemperatureSensorEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Temperature sensors."
INDEX { temperatureSensorId }
::= { temperatureSensorTable 1 }
TemperatureSensorEntry ::=
SEQUENCE {
temperatureSensorId
IntegerIndex,
temperatureSensorDescription
DisplayString,
temperatureSensorValue
IntegerMillis
}
temperatureSensorId OBJECT-TYPE
SYNTAX IntegerIndex (1..2147483647)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A unique index of the temperature sensor. It is constant between
different models of one device family."
::= { temperatureSensorEntry 1 }
temperatureSensorDescription OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Description of the temperature sensor. Should describe, where temperature is measured."
::= { temperatureSensorEntry 2 }
temperatureSensorValue OBJECT-TYPE
SYNTAX IntegerMillis
UNITS "C"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The temperature value in 1/1000 of the Celcium degree. For example, 25000 = 25C, -10500 = -10.5C."
::= { temperatureSensorEntry 3 }
--- time group
timeSourceNumber OBJECT-TYPE
SYNTAX IntegerNumber
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of device's UTC time sources."
::= { time 1 }
timeSourceTable OBJECT-TYPE
SYNTAX SEQUENCE OF TimeSourceEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Table of UTC time sources present on device. Examples are UTC,
satellite (GNSS) etc."
::= { time 2 }
timeSourceEntry OBJECT-TYPE
SYNTAX TimeSourceEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Time source."
INDEX { timeSourceId }
::= { timeSourceTable 1 }
TimeSourceEntry ::=
SEQUENCE {
timeSourceId
IntegerIndex,
timeSourceName
DisplayString,
timeSourceStratum
Integer32,
timeSourceValue
DateAndTime
}
timeSourceId OBJECT-TYPE
SYNTAX IntegerIndex (1..2147483647)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A unique index of the time source. It is constant between
reconfigurations of a device."
::= { timeSourceEntry 1 }
timeSourceName OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Name of the time source. For example: NTP."
::= { timeSourceEntry 2 }
timeSourceStratum OBJECT-TYPE
SYNTAX Integer32 (1..16)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Clock source stratum as it is defined in NTP."
::= { timeSourceEntry 3 }
timeSourceValue OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"UTC time as reported by this source. If source is not ready
(no connection to server or no signal), zero-length octet string
is returned."
::= { timeSourceEntry 4 }
timeZone OBJECT-TYPE
SYNTAX Integer32 (-1440..1440)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Displacement, in minutes, of local time relative to UTC.
For example, 240 is UTC+04:00 (Moscow Time),
-480 is UTC-08:00 (Pacific Standard Time)."
::= { time 3 }
-- local power sources group
powerSourceNumber OBJECT-TYPE
SYNTAX IntegerNumber
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of device's local power sources."
::= { localPower 1 }
powerSourceTable OBJECT-TYPE
SYNTAX SEQUENCE OF PowerSourceEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Table of local power sources available to the device, listed in
priority order."
::= { localPower 2 }
powerSourceEntry OBJECT-TYPE
SYNTAX PowerSourceEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Power source."
INDEX { powerSourceId }
::= { powerSourceTable 1 }
PowerSourceEntry ::=
SEQUENCE {
powerSourceId
IntegerIndex,
powerSourceName
DisplayString,
powerSourceNominalVoltage
Integer32,
powerSourceStatus
INTEGER
}
powerSourceId OBJECT-TYPE
SYNTAX IntegerIndex (1..2147483647)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A unique index of the power source."
::= { powerSourceEntry 1 }
powerSourceName OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Name of the power source. For example: 48V-a."
::= { powerSourceEntry 2 }
powerSourceNominalVoltage OBJECT-TYPE
SYNTAX Integer32
UNITS "V"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Nominal voltage of the power source."
::= { powerSourceEntry 3 }
powerSourceStatus OBJECT-TYPE
SYNTAX INTEGER {
available(1),
unavailable(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Availability status of this power source."
::= { powerSourceEntry 4 }
--- SFP DDM group
SfpPowerMilliWatt ::= TEXTUAL-CONVENTION
DISPLAY-HINT "d-4"
STATUS current
DESCRIPTION "SFP optical power from 0 to 6.5535 mW, in 1E-4 mW units."
SYNTAX Integer32
sfpDDMNumber OBJECT-TYPE
SYNTAX IntegerNumber
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of the sfp modules the device has."
::= { sfpDDM 1 }
sfpDDMTable OBJECT-TYPE
SYNTAX SEQUENCE OF SfpDDMEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Table of DDM values read from SFP"
::= { sfpDDM 2 }
sfpDDMEntry OBJECT-TYPE
SYNTAX SfpDDMEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"SFP Digital diagnostics monitoring"
INDEX { sfpDDMId }
::= { sfpDDMTable 1}
SfpDDMEntry ::=
SEQUENCE {
sfpDDMId
IntegerIndex,
sfpDDMTemperature
IntegerMillis,
sfpDDMSupplyVoltage
IntegerMillis,
sfpDDMTxBiasCurrent
IntegerWithDecimal,
sfpDDMTxOutputmW
SfpPowerMilliWatt,
sfpDDMTxOutputdBm
IntegerWithDecimal,
sfpDDMRxInputmW
SfpPowerMilliWatt,
sfpDDMRxInputdBm
IntegerWithDecimal,
sfpDDMMediaType
INTEGER,
sfpDDMPresence
INTEGER,
sfpDDMIfIndex
InterfaceIndex
}
sfpDDMId OBJECT-TYPE
SYNTAX IntegerIndex (1..2147483647)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An Index of DDM value"
::= { sfpDDMEntry 1 }
sfpDDMTemperature OBJECT-TYPE
SYNTAX IntegerMillis(-128000..128000)
UNITS "C"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Internally measured transceiver temperature in range from -128C to +128C. "
::= { sfpDDMEntry 2 }
sfpDDMSupplyVoltage OBJECT-TYPE
SYNTAX IntegerMillis(0..65535)
UNITS "V"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Internally measured transceiver supply voltage in range from 0 to +6.5535 Volts."
::= { sfpDDMEntry 3 }
sfpDDMTxBiasCurrent OBJECT-TYPE
SYNTAX IntegerWithDecimal(0..1310)
UNITS "mA"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Measured TX bias current in range from 0 to 131.0 mA"
::= { sfpDDMEntry 4 }
sfpDDMTxOutputmW OBJECT-TYPE
SYNTAX SfpPowerMilliWatt(0..65535)
UNITS "mW"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Measured TX output power in range from 0 to 6.5535 mW"
::= { sfpDDMEntry 5 }
sfpDDMTxOutputdBm OBJECT-TYPE
SYNTAX IntegerWithDecimal(-400..82)
UNITS "dBm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Measured TX output power in range from -40 to +8.2 dBm"
::= { sfpDDMEntry 6 }
sfpDDMRxInputmW OBJECT-TYPE
SYNTAX SfpPowerMilliWatt(0..65535)
UNITS "mW"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Measured RX received optical power from 0 to 6.5535 mW."
::= { sfpDDMEntry 7 }
sfpDDMRxInputdBm OBJECT-TYPE
SYNTAX IntegerWithDecimal(-400..82)
UNITS "dBm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Measured RX received optical power from -40 to +8.2 dBm."
::= { sfpDDMEntry 8 }
sfpDDMMediaType OBJECT-TYPE
SYNTAX INTEGER {
fiber (1),
copper (2),
other (3),
unknown (4)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object returns sfpMedia type.
when module is not mounted return value is unknown (3)"
::= { sfpDDMEntry 9 }
sfpDDMPresence OBJECT-TYPE
SYNTAX INTEGER {
present (1),
absent (2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object indicates if specified SFP interface plugged or not
present (1) indicates that SFP interface is plugged.
absent (2) indicates that SFP interface is unplugged."
::= { sfpDDMEntry 10 }
sfpDDMIfIndex OBJECT-TYPE
SYNTAX InterfaceIndex
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Index of interface in interfaces table, which state this
SFP interface represents."
::= { sfpDDMEntry 11 }
--- IO group
-- io.DIn group
ioDInNumber OBJECT-TYPE
SYNTAX IntegerNumber
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of digital inputs the device has"
::= { ioDIn 1}
ioDInTable OBJECT-TYPE
SYNTAX SEQUENCE OF IoDInEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Discrete input table represents all discrete (digital) inputs present and
configured in the device, including voltage inputs, dry contact inputs and
any other."
::= { ioDIn 2 }
ioDInEntry OBJECT-TYPE
SYNTAX IoDInEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Discrete (digital) input"
INDEX { dInId }
::= { ioDInTable 1 }
IoDInEntry ::=
SEQUENCE {
dInId
IntegerIndex,
dInName
DisplayString,
dInState
INTEGER,
dInNormalState
INTEGER,
dInAlarmSeverity
INTEGER,
dInDescription
DisplayString,
dInTrapEnable
INTEGER
}
dInId OBJECT-TYPE
SYNTAX IntegerIndex (1..2147483647)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A unique index of discrete input. It should remain constant through
any reconfiguration and reboot of the device."
::= { ioDInEntry 1 }
dInName OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Discrete input name, typically - connector marking."
::= { ioDInEntry 2 }
dInState OBJECT-TYPE
SYNTAX INTEGER {
open(1),
closed(2),
high(3),
low(4)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Discrete input state. For voltage input values are high(3) or low(4).
For npn or dry contact input it is open(1) or closed(2)."
::= { ioDInEntry 3 }
dInNormalState OBJECT-TYPE
SYNTAX INTEGER {
open(1),
closed(2),
high(3),
low(4),
any(5)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Normal discrete input state. If it is any(5), then input is considered
informative, else it is has normal (normally open or normally closed) and
alarm state."
::= { ioDInEntry 4 }
dInAlarmSeverity OBJECT-TYPE
SYNTAX INTEGER {
no(1),
nonurgent(2),
urgent(3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"dInAlarmSeverity allows systemAlarm variable to be triggered by the state
of the input. Setting its to no(1) means that systemAlarm is not triggered;
setting its to nonurgent(2) or urgent(3) will trigger the systemAlarm if
dInState is not equal to dInNormalState."
::= { ioDInEntry 5 }
dInDescription OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"User configurable description: input purpose, meaning, net."
::= { ioDInEntry 6 }
dInTrapEnable OBJECT-TYPE
SYNTAX INTEGER {
true(1),
false(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"If true(1), trap will be sent on each change of dInState.
If false(2), no traps will be sent"
::= { ioDInEntry 7 }
-- io.Out group
ioDOutNumber OBJECT-TYPE
SYNTAX IntegerNumber
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of digital outputs the device has"
::= { ioDOut 1}
ioDOutTable OBJECT-TYPE
SYNTAX SEQUENCE OF IoDOutEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Discrete output table represents all discrete outputs present and
configured in the device, including relay outputs, voltage outputs,
and any other."
::= { ioDOut 2 }
ioDOutEntry OBJECT-TYPE
SYNTAX IoDOutEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Discrete output"
INDEX { dOutId }
::= { ioDOutTable 1 }
IoDOutEntry ::=
SEQUENCE {
dOutId
IntegerIndex,
dOutName
DisplayString,
dOutState
INTEGER,
dOutNormalState
INTEGER,
dOutAlarmSeverity
INTEGER,
dOutDescription
DisplayString,
dOutTrapEnable
INTEGER
}
dOutId OBJECT-TYPE
SYNTAX IntegerIndex (1..2147483647)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A unique index of discrete output. It should remain constant through
any reconfiguration and reboot of the device."
::= { ioDOutEntry 1 }
dOutName OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Discrete output name, typically - connector marking."
::= { ioDOutEntry 2 }
dOutState OBJECT-TYPE
SYNTAX INTEGER {
active(1),
inactive(2),
high(3),
low(4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Discrete output state. For voltage output values are high(3) or low(4).
For open-drain, npn, relay coil output (and other) it is active(1) or inactive(2).
active(1) : coil energized, open-drain or npn output conducting current.
inactive(2): coil de-energized, open-drain or npn output not conducting."
::= { ioDOutEntry 3 }
dOutNormalState OBJECT-TYPE
SYNTAX INTEGER {
open(1),
closed(2),
high(3),
low(4),
any(5)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Normal discrete output state. If it is any(5), then input is considered
informative, else it is has normal (normally open or normally closed) and
alarm state."
::= { ioDOutEntry 4 }
dOutAlarmSeverity OBJECT-TYPE
SYNTAX INTEGER {
no(1),
nonurgent(2),
urgent(3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"dOutAlarmSeverity allows systemAlarm variable to trigger the state
of the output. Setting its to no(1) means that systemAlarm will not trigger;
setting its to nonurgent(2) or urgent(3) will trigger the output by changing
the dOutState to the opposite of dOutNormalState."
::= { ioDOutEntry 5 }
dOutDescription OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"User configurable description: output purpose, connected load, net."
::= { ioDOutEntry 6 }
dOutTrapEnable OBJECT-TYPE
SYNTAX INTEGER {
true(1),
false(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"If true(1), trap will be sent on each change of dOutState.
If false(2), no traps will be sent"
::= { ioDOutEntry 7 }
--- statReset entity
statReset OBJECT-TYPE
SYNTAX INTEGER {
reset(1),
readValue(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Writing reset(1) perform a device statistics reset.
All device statistics should be re-initialized.
Read always returns readValue(2)."
::= { stats 11 }
--- maintenance.tftp group
tftpServerIP OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The IP address of the server from which the file is loaded.
This value is not stored between device reboots and should
be set before each TFTP operation."
::= { tftp 1 }
tftpSoftFileName OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The remote filename for firmware upgrade.
This value is not stored between device reboots and should
be set before each TFTP operation."
::= { tftp 2 }
tftpConfFileName OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The remote filename for the up and download the startup-config.
This value is not stored between device reboots and should
be set before each TFTP operation."
::= { tftp 3 }
tftpConnectionTimeout OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Time the device will wait for reply from TFTP server,
during connection and while transferring a block of data.
While waiting, the device will retransmit it's request
each 8 seconds (typically). Thus it is reasonable to set
the timeout to a multiple of 8 seconds.
If during tftpConnectionTimeout device will not get a responce
from the server, current TFTP operation will be retried several
times (set by tftpNumRetries) before ending with and error."
::= { tftp 4 }
tftpNumRetries OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Number of times the device will retry to connect and perform
requested operation (firmware download, configuration up/download)
before stopping with error status."
::= { tftp 5 }
tftpTransCmd OBJECT-TYPE
SYNTAX INTEGER {
noOp (1),
readValue (2),
swDownload (3),
configDownload (4),
configUpload (5),
allDownload (6),
sdSwUpload (9),
sdSwDownload (10),
sdConfigUpload (11),
sdConfigDownload (12),
sdLoaderUpload (13),
sdLoaderDownload (14),
sdCreateSnapshot (15)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object, when read, always returns readValue(2).
Setting this object will initiate following actions:
swDownload(3)
Download the firmware from TFTP server, filename on the server
is specified by tftpSoftFileName.
configDownload(4)
Download the startup-config from the TFTP server, filename on
the server is specified by tftpConfFileName.
configUpLoad(5)
Download the startup-config to the TFTP-Server, filename on the
server is specified by tftpConfFileName.
allDownload(6)
Download the startup-config and firmware from the TFTP server.
sdSwUpload(9)
Upload software from main flash to SD card
sdSwDownload(10)
Download software from SD card
sdConfigUpload(11)
Upload the startup-config from main flash to SD card
sdConfigDownload(12)
Download the startup-config from SD card
sdLoaderUpload(13)
Upload bootloader from main flash to SD card
sdLoaderDownload(14)
Download bootloader from SD card
sdCreateSnapshot(15)
Upload Software, Loader and startup-config to SD card.
Create filesystem if necesary
noOp(1)
Cancel all running SNMP-initiated TFTP operations.
TFTP server IP address is configured by tftpServerIP variable.
If device does not perform any other maintenance operations, the
command will be executed, otherwise it will be denied.
In case of command execution:
The value of tftpLastOp will change to the value of the command.
tftpTransferStatus will reflect transfer progress (connecting-
transferringData-endedOk/error).
Current timestamp will be saved into tftpLastOpTime variable.
During the execution a series of tftpStatusChange is sent.
In case of denial:
tftpLastOp and tftpTransferStatus will not be affected.
Current timestamp is also not saved into tftpLastOpTime variable.
By quering tftpLastOpTime before and after setting the tftpTransCmd
one can find out if the command was denied.
Current operation that caused the denial can be queried by tftpLastOp.
tftpStatusChange with tftpTransferStatus value of busyByOther is sent."
::= { tftp 6 }
tftpLastOp OBJECT-TYPE
SYNTAX INTEGER {
noOp (1),
tftpSwDownload (3),
tftpConfigDownload (4),
tftpConfigUpload (5),
otherSwDownload (6),
otherConfigDownLoad (7),
otherConfigUpload (8),
sdSwUpload (9),
sdSwDownload (10),
sdConfigUpload (11),
sdConfigDownload (12),
sdLoaderUpload (13),
sdLoaderDownload (14),
sdCreateSnapshot (15)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object returns the last executed maintenance operation,
regardless was it successful or not. It reports following actions:
noOp(1)
No maintenance operations were requested since last restart of the device.
tftpSwDownload(3)
Software download initiated from SNMP.
tftpConfigDownload(4)
Startup-config download initiated from SNMP.
tftpConfigUpload(5)
Startup-config upload initiated from SNMP.
otherSwDownload(6)
Software download, either TFTP or any other way, not initiated from SNMP.
otherConfigDownload(7)
Startup-config download, either TFTP or any other way, not initiated from SNMP.
otherConfigUpload(8)
Startup-config upload, either TFTP or any other way, not initiated from SNMP.
sdSwUpload(9)
Upload software from main flash to SD card
sdSwDownload(10)
Download software from SD card
sdConfigUpload(11)
Upload the startup-config from main flash to SD card
sdConfigDownload(12)
Download the startup-config from SD card
sdLoaderUpload(13)
Upload bootloader from main flash to SD card
sdLoaderDownload(14)
Download bootloader from SD card
sdCreateSnapshot(15)
Upload Software, Loader and startup-config to SD card.
Create filesystem if necesary"
::= { tftp 7 }
tftpTransferStatus OBJECT-TYPE
SYNTAX INTEGER {
noOp(1),
connecting(2),
transferringData(3),
endedOk(4),
error(5),
busyByOther(6)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Status of SNMP-initiated TFTP transfer. Results:
noOp(1)
Default, no TFTP operation was in progress.
connecting(2)
Device is connecting to the server specified by tftpServerIP.
transferringData(3)
TFTP data transfer is in progress.
endedOk(4)
TFTP transfer ended with success.
error(5)
TFTP data transfer ended with an Error, (e.g. server timeout or
remote filename not found). Check TFTP server log file for details.
busyByOther(6)
This value can never be read directly from the MIB tree. It is
used only in tftpStatusChange to notify that device is bysy with
other maintenance operation and the request for another operation
was denied.
If tftpLastOp is tftpSwDownload(3), tftpConfigDownload(4) or tftpConfigUpload(5),
this variable shows the status of exactly that operation. Transfers initiated by
other means (for example CLI command TFTP operation or normal software download),
do not change this variable. This way one can get full status of SNMP-initiated
up/download without interference."
::= { tftp 8 }
tftpLastOpTime OBJECT-TYPE
SYNTAX TimeTicks
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The time in timeticks when last maintenance operation (TFTP software download or
configuration up/download) was executed from SNMP by setting tftpTransCmd.
If operation execution was denied, this variable is not affected.
By comparing tftpLastOpTime before and after tftpTransCmd setting one can
find out if the command was successful or denied."
::= { tftp 9 }
tftpSoftConfirm OBJECT-TYPE
SYNTAX INTEGER {
softConfirm(1),
readValue(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Writing softConfirm(1) to tftpSoftConfirm will confirm previously uploaded firmware.
Read always returns readValue(2)."
::= { tftp 10 }
tftpProtocolVersion OBJECT-TYPE
SYNTAX INTEGER {
tftp(1),
ftp(2),
sftp(3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Allows protocol selection between tftp(1), ftp(2) and sftp(3) for up/download.
This value is not stored between device reboots and should
be set before each operation."
::= { tftp 11 }
tftpServerUserName OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The Username for Server access.
This value is not stored between device reboots and should
be set before each operation."
::= { tftp 12 }
tftpServerUserPass OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The User Password for Server access.
This value is not stored between device reboots and should
be set before each operation."
::= { tftp 13 }
tftpServerPortNumber OBJECT-TYPE
SYNTAX Integer32 (0..65535)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The port number for accessing FTP or SFTP server.
This value is not stored between device reboots and should
be set before each operation."
::= { tftp 14 }
macFilterConfigTable OBJECT-TYPE
SYNTAX SEQUENCE OF MacFilterConfigEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Table representing MAC-based filter configuration of network interfaces."
::= { macFilter 1 }
macFilterConfigEntry OBJECT-TYPE
SYNTAX MacFilterConfigEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"MAC-based filter configuration of one interface"
INDEX { macFilterConfigIfIndex }
::= { macFilterConfigTable 1 }
MacFilterConfigEntry ::=
SEQUENCE {
macFilterConfigIfIndex
IntegerIndex,
macFilterConfigStatus --- On/Off
INTEGER,
macFilterConfigAction --- Filter/Indicate/Block
INTEGER
}
macFilterConfigIfIndex OBJECT-TYPE
SYNTAX IntegerIndex(1..2147483647)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Index in interfaces table of the configured interface."
::= { macFilterConfigEntry 1 }
macFilterConfigStatus OBJECT-TYPE
SYNTAX INTEGER {
on(1),
off(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates, whether filtering is on(1) or off(2)."
::= { macFilterConfigEntry 2 }
macFilterConfigAction OBJECT-TYPE
SYNTAX INTEGER {
filter(1),
indicate(2),
block(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Security action when non-permitted frame is received:
filter - just drop the frame;
indicate - drop the frame and send trap;
block - drop the frame, send trap and permanently block the interface."
::= { macFilterConfigEntry 3 }
macFilterWhitelistTable OBJECT-TYPE
SYNTAX SEQUENCE OF MacFilterWhitelistEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"White list of allowed MAC addresses."
::= { macFilter 2 }
macFilterWhitelistEntry OBJECT-TYPE
SYNTAX MacFilterWhitelistEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"White list"
INDEX { macFilterWhitelistIfIndex, macFilterWhitelistIndex }
::= { macFilterWhitelistTable 1 }
MacFilterWhitelistEntry ::=
SEQUENCE {
macFilterWhitelistIndex
IntegerIndex,
macFilterWhitelistIfIndex
IntegerIndex,
macFilterWhitelistMAC
MacAddress
}
macFilterWhitelistIndex OBJECT-TYPE
SYNTAX IntegerIndex(1..2147483647)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Index in whitelist table."
::= { macFilterWhitelistEntry 1 }
macFilterWhitelistIfIndex OBJECT-TYPE
SYNTAX IntegerIndex(1..2147483647)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"IfIndex of the related interface."
::= { macFilterWhitelistEntry 2 }
macFilterWhitelistMAC OBJECT-TYPE
SYNTAX MacAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Permitted MAC address"
::= { macFilterWhitelistEntry 3 }
macFilterViolationsTable OBJECT-TYPE
SYNTAX SEQUENCE OF MacFilterViolationsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"List of several last MAC address security violations."
::= { macFilter 3 }
macFilterViolationsEntry OBJECT-TYPE
SYNTAX MacFilterViolationsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Violations list"
INDEX { macFilterViolationsIndex }
::= { macFilterViolationsTable 1 }
MacFilterViolationsEntry ::=
SEQUENCE {
macFilterViolationsIndex
IntegerIndex,
macFilterViolationsIfIndex
IntegerIndex,
macFilterViolationsMAC
MacAddress,
macFilterViolationsTimestamp
TimeTicks
}
macFilterViolationsIndex OBJECT-TYPE
SYNTAX IntegerIndex(1..2147483647)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Index in violations table."
::= { macFilterViolationsEntry 1 }
macFilterViolationsIfIndex OBJECT-TYPE
SYNTAX IntegerIndex
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"IfIndex of the related interface."
::= { macFilterViolationsEntry 2 }
macFilterViolationsMAC OBJECT-TYPE
SYNTAX MacAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Violating MAC address"
::= { macFilterViolationsEntry 3 }
macFilterViolationsTimestamp OBJECT-TYPE
SYNTAX TimeTicks
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Timestamp of last time an action was taken against security
violation performed by this MAC address on this interface.
Measured in 1/100s of second from the last start of the unit -
same as sysUpTime."
::= { macFilterViolationsEntry 4 }
--- Notifications (Traps)
tlmStatusChange NOTIFICATION-TYPE
OBJECTS { tlmStatus, tlmLastStatusChange }
STATUS current
DESCRIPTION
"A tlmStatusChange trap is sent when the
value of an instance tlmStatus changes. It
can be utilized by an NMS to trigger polls."
::= { nateksTraps 1 }
alarmValueChange NOTIFICATION-TYPE
OBJECTS { alarmId, alarmIfIndex, alarmName, alarmValue, alarmDisplayType, alarmCutoff, ifDescr }
STATUS current
--&FILTNAME "MAJOR ALARM ON"
--&ACTIONS {log, critical}
--&CLEARS {"ALARM OFF", "ALARM CUTOFF"}
--&MATCH {alarmIfIndex, alarmName, alarmValue "on", alarmCutoff "off", alarmDisplayType "major"}
--&MESG "$7 alarm $3 ON"
--&FILTNAME "MINOR ALARM ON"
--&ACTIONS {log, major}
--&CLEARS {"ALARM OFF", "ALARM CUTOFF"}
--&MATCH {alarmIfIndex, alarmName, alarmValue "on", alarmCutoff "off", alarmDisplayType "minor"}
--&MESG "$7 alarm $3 ON"
--&FILTNAME "MAINTENANCE ALARM ON"
--&ACTIONS {log, minor}
--&CLEARS {"ALARM OFF", "ALARM CUTOFF"}
--&MATCH {alarmIfIndex, alarmName, alarmValue "on", alarmCutoff "off", alarmDisplayType "maintenance"}
--&MESG "$7 alarm $3 ON"
--&FILTNAME "ALARM OFF"
--&ACTIONS {log, normal}
--&CLEARS {"MAJOR ALARM ON", "MINOR ALARM ON", "MAINTENANCE ALARM ON", "ALARM CUTOFF"}
--&MATCH {alarmIfIndex, alarmName, alarmValue "off", alarmCutoff "off"}
--&MESG "$7 alarm $3 OFF"
--&FILTNAME "ALARM CUTOFF"
--&ACTIONS {log, normal}
--&CLEARS {"MAJOR ALARM ON", "MINOR ALARM ON", "MAINTENANCE ALARM ON", "ALARM OFF"}
--&MATCH {alarmIfIndex, alarmName, alarmCutoff "on"}
--&MESG "$7 alarm $3 OFF"
DESCRIPTION
"A alarmValueChange trap is sent when alarm value changes.
It can be utilized by an NMS to trigger polls."
::= { nateksTraps 2 }
tftpStatusChange NOTIFICATION-TYPE
OBJECTS { tftpLastOp, tftpTransferStatus, tftpLastOpTime }
STATUS current
--&FILTNAME "TFTP denied"
--&ACTIONS {log, minor}
--&MATCH {tftpTransferStatus "busyByOther"}
--&MESG "TFTP transfer was denied because operation $'1 is still in progress"
--&FILTNAME "TFTP connecting"
--&ACTIONS {log, warning}
--&MATCH {tftpLastOp, tftpLastOpTime, tftpTransferStatus "connecting"}
--&MESG "TFTP operation $'1 status: connecting..."
--&FILTNAME "TFTP transfer"
--&ACTIONS {log, warning}
--&CLEARS {"TFTP connecting"}
--&MATCH {tftpLastOp, tftpLastOpTime, tftpTransferStatus "transferringData"}
--&MESG "TFTP operation $'1 status: transferring..."
--&FILTNAME "TFTP ended OK"
--&ACTIONS {log, normal}
--&CLEARS {"TFTP connecting", "TFTP transfer"}
--&MATCH {tftpLastOp, tftpLastOpTime, tftpTransferStatus "endedOk"}
--&MESG "TFTP operation $'1 status: OK"
--&FILTNAME "TFTP error"
--&ACTIONS {log, minor}
--&CLEARS {"TFTP connecting", "TFTP transfer"}
--&MATCH {tftpLastOp, tftpLastOpTime, tftpTransferStatus "error"}
--&MESG "TFTP operation $'1 status: error"
DESCRIPTION
"This trap is sent during the process of SNMP-initiated TFTP maintenance
command (TFTP software download or configuration up/download) to report
current execution status. In this case tftpLastOp shows the current
operation, tftpLastOpTime indicates starting time of current operation,
tftpTransferStatus indicates status of the transfer.
If the command is denied, this trap is also sent with tftpTransferStatus
value of busyByOther. In this case tftpLastOp indicates the operation that
conflicted with the command."
::= { nateksTraps 3 }
macFilterViolation NOTIFICATION-TYPE
OBJECTS { macFilterViolationsIfIndex, ifDescr, macFilterViolationsMAC, macFilterConfigAction }
STATUS current
--&FILTNAME "MAC violation: filtered"
--&ACTIONS {log, warning}
--&MATCH { macFilterConfigAction "indicate"}
--&MESG "$2 access violation, MAC $3"
--&FILTNAME "MAC violation: blocked"
--&ACTIONS {log, major}
--&MATCH { macFilterConfigAction "block"}
--&MESG "$2 blocked due to access violation by MAC $3"
DESCRIPTION
"This trap is sent to indicate that MAC filter access violation
has happened and specific security action will be performed.
Variables:
macFilterViolationsIfIndex, ifDescr - index and name of interface;
macFilterViolationsMAC - violating MAC;
macFilterConfigAction - action to be performed.
"
::= { nateksTraps 4 }
dInStateChange NOTIFICATION-TYPE
OBJECTS { dInName, dInState, dInNormalState, dInDescription }
STATUS current
--&FILTNAME "Normally-open Closed"
--&ACTIONS {log, warning}
--&MATCH { dInNormalState "open", dInState "closed" }
--&MESG "Input: $1 with description: $4 Closed"
--&FILTNAME "Normally-closed Open"
--&ACTIONS {log, warning}
--&MATCH { dInNormalState "closed", dInState "open" }
--&MESG "Input: $1 with description: $4 Opened"
--&FILTNAME "Normally-open Open"
--&ACTIONS {log, normal}
--&CLEARS {"Normally-open Closed"}
--&MATCH { dInNormalState "open", dInState "open" }
--&MESG "Input: $1 with description: $4 Opened"
--&FILTNAME "Normally-closed Closed"
--&CLEARS {"Input trigger: Normally-closed Open"}
--&ACTIONS {log, normal}
--&MATCH { dInNormalState "closed", dInState "closed" }
--&MESG "Input: $1 with description: $4 Closed"
DESCRIPTION
"This trap is sent to indicate that input state has changed."
::= { nateksTraps 5 }
dOutStateChange NOTIFICATION-TYPE
OBJECTS { dOutName, dOutState, dOutNormalState, dOutDescription }
STATUS current
--&FILTNAME "Output Active"
--&ACTIONS {log, warning}
--&MATCH { dOutName, dOutState "active", dOutDescription }
--&MESG "Output $1 with description: $4 Active"
--&FILTNAME "Output Inactive"
--&ACTIONS {log, warning}
--&MATCH { dOutName, dOutState "inactive", dOutDescription }
--&MESG "Output $1 with description: $4 Inactive"
DESCRIPTION
"This trap is sent to indicate that output state has changed."
::= { nateksTraps 6 }
nateksMinimalGroup OBJECT-GROUP
OBJECTS {
systemAlarm,
systemReset
}
STATUS current
DESCRIPTION
"A minimal collection of objects requred from any supporting device."
::= { nateksMIBGroup 1 }
nateksCommonInfoGroup OBJECT-GROUP
OBJECTS {
model,
softwareVersion
}
STATUS current
DESCRIPTION
"Basic unit information regarding model and software of a unit."
::= { nateksMIBGroup 2 }
nateksCommonExtGroup OBJECT-GROUP
OBJECTS {
model,
id,
hardwareVersion,
softwareVersion,
softwareDate,
moduleType,
subrackAddress,
errorCode,
serialNumber
}
STATUS current
DESCRIPTION
"Extended unit information regarding hardware and software of a unit."
::= { nateksMIBGroup 3 }
nateksConfigBasicGroup OBJECT-GROUP
OBJECTS {
configDefault,
configNumberValues,
valueName,
valueRunning
}
STATUS current
DESCRIPTION
"Basic configuration management interface."
::= { nateksMIBGroup 4 }
nateksConfigConfirmedGroup OBJECT-GROUP
OBJECTS {
configDefault,
configNumberValues,
valueName,
valueType,
valueStatus,
valueStartup,
valueRunning,
valueNew,
configApplyAll,
configConfirm
}
STATUS current
DESCRIPTION
"Minimal configuration management interface with support
for Apply-Confirm configuration behaviour."
::= { nateksMIBGroup 5 }
nateksConfigBackupGroup OBJECT-GROUP
OBJECTS {
valueBackup,
configBackup,
configRestore
}
STATUS current
DESCRIPTION
"Local configuration backup management interface."
::= { nateksMIBGroup 6 }
nateksConfigGroupsGroup OBJECT-GROUP
OBJECTS {
valueGroup,
valueGroupName,
configNumberGroups,
groupName,
groupType,
groupStatus
}
STATUS current
DESCRIPTION
"Management interface for variable groups."
::= { nateksMIBGroup 7 }
nateksConfigRWGroup OBJECT-GROUP
OBJECTS { configRW }
STATUS current
DESCRIPTION
"Management interface for full configuration profile read/write."
::= { nateksMIBGroup 8 }
nateksG826Group OBJECT-GROUP
OBJECTS {
g826Number,
g826Reset,
g826IfIndex,
g826Name,
g826EB,
g826ES,
g826SES,
g826BBE,
g826AvailableTime,
g826UnavailableTime,
g826StatReset
}
STATUS deprecated
DESCRIPTION
"Use of g826Table is deprecated in favor of ifG826Table."
::= { nateksMIBGroup 9 }
nateksIfG826Group OBJECT-GROUP
OBJECTS {
g826Number,
g826Reset,
ifG826Name,
ifG826EB,
ifG826ES,
ifG826SES,
ifG826BBE,
ifG826AvailableTime,
ifG826UnavailableTime,
ifG826StatReset
}
STATUS current
DESCRIPTION
"G.826 statistics information and management."
::= { nateksMIBGroup 10 }
nateksAlarmGroup OBJECT-GROUP
OBJECTS {
alarmNumber,
alarmTrapEnable,
alarmId,
alarmIfIndex,
alarmName,
alarmValue,
alarmCutoff,
alarmType,
alarmDisplayType
}
STATUS current
DESCRIPTION
"Old style alarm table. Using ifAlarmTable is more convenient than alarmTable.
Members of this group are included into alarmValueChange notification."
::= { nateksMIBGroup 11 }
nateksIfAlarmGroup OBJECT-GROUP
OBJECTS {
alarmNumber,
alarmTrapEnable,
ifAlarmId,
ifAlarmIfIndex,
ifAlarmName,
ifAlarmValue,
ifAlarmCutoff,
ifAlarmType,
ifAlarmDisplayType
}
STATUS current
DESCRIPTION
"Alarm information and management."
::= { nateksMIBGroup 12 }
nateksTlmGroup OBJECT-GROUP
OBJECTS {
tlmNumber,
tlmClear,
tlmName,
tlmStatus,
tlmLastStatusChange,
tlmSetup,
tlmTrapEnable
}
STATUS current
DESCRIPTION
"TLM information and management."
::= { nateksMIBGroup 13 }
nateksDSLGroup OBJECT-GROUP
OBJECTS {
dslChannelNumber,
dslUnitType,
dslChannelIfIndex,
dslChannelMode,
dslChannelStandard,
dslChannelClockReference,
dslChannelLineCodeConfig,
dslChannelPSDConfig,
dslChannelBaserateConfig,
dslChannelLineCode,
dslChannelPSD,
dslChannelBaserate,
dslChannelLineRate,
dslChannelPayloadRate,
dslChannelStatus,
dslChannelNMR,
dslChannelPowerBackoff,
dslChannelFarEndPowerBackoff,
dslChannelLoopAttenuation,
dslChannelEOCNumber
}
STATUS current
DESCRIPTION
"DSL channel information."
::= { nateksMIBGroup 14 }
nateksDSLMultipairGroup OBJECT-GROUP
OBJECTS {
dslGroupNumber,
dslGroupType,
dslGroupMainChannel,
dslGroupChannel1,
dslGroupChannel2,
dslGroupChannel3,
dslGroupChannel4
}
STATUS current
DESCRIPTION
"DSL multi-pair bonding information."
::= { nateksMIBGroup 15 }
nateksDSLLTUGroup OBJECT-GROUP
OBJECTS {
dslChannelRegeneratorNumber,
dslChannelRemotePower,
dslChannelRemotePowerVoltage
}
STATUS current
DESCRIPTION
"Information aout remote power and regenerators present only on LTU/NTU DSL units."
::= { nateksMIBGroup 16 }
nateksDSLRegenerationGroup OBJECT-GROUP
OBJECTS {
dslRegenerationChannels,
dslRegenerationSide1,
dslRegenerationSide2
}
STATUS current
DESCRIPTION
"DSL regeneration channels information."
::= { nateksMIBGroup 17 }
nateksIndicationGroup OBJECT-GROUP
OBJECTS {
indicationLedNumber,
indicationLedDescription,
indicationLedState,
indicationLedFlash
}
STATUS current
DESCRIPTION
"LED indication status."
::= { nateksMIBGroup 18 }
nateksTemperatureGroup OBJECT-GROUP
OBJECTS {
temperatureSensorNumber,
temperatureSensorDescription,
temperatureSensorValue
}
STATUS current
DESCRIPTION
"Temperature sensors data."
::= { nateksMIBGroup 19 }
nateksTimeGroup OBJECT-GROUP
OBJECTS {
timeSourceNumber,
timeSourceName,
timeSourceStratum,
timeSourceValue,
timeZone
}
STATUS current
DESCRIPTION
"Data from time reference sources."
::= { nateksMIBGroup 20 }
nateksLocalPowerGroup OBJECT-GROUP
OBJECTS {
powerSourceNumber,
powerSourceName,
powerSourceNominalVoltage,
powerSourceStatus
}
STATUS current
DESCRIPTION
"Local power sources status."
::= { nateksMIBGroup 21 }
nateksTFTPManagementGroup OBJECT-GROUP
OBJECTS {
tftpServerIP,
tftpSoftFileName,
tftpConfFileName,
tftpConnectionTimeout,
tftpNumRetries,
tftpTransCmd,
tftpLastOp,
tftpTransferStatus,
tftpLastOpTime,
tftpSoftConfirm,
tftpProtocolVersion,
tftpServerUserName,
tftpServerUserPass,
tftpServerPortNumber
}
STATUS current
DESCRIPTION
"Software upload and configuration upload/download via TFTP protocol."
::= { nateksMIBGroup 22 }
nateksMacFilterGroup OBJECT-GROUP
OBJECTS {
macFilterConfigStatus,
macFilterConfigAction,
macFilterWhitelistMAC,
macFilterViolationsIfIndex,
macFilterViolationsMAC,
macFilterViolationsTimestamp
}
STATUS current
DESCRIPTION
"MAC-based Ethernet port access control group."
::= { nateksMIBGroup 23 }
nateksSfpDDMGroup OBJECT-GROUP
OBJECTS {
sfpDDMNumber,
sfpDDMTemperature,
sfpDDMSupplyVoltage,
sfpDDMTxBiasCurrent,
sfpDDMTxOutputmW,
sfpDDMTxOutputdBm,
sfpDDMRxInputmW,
sfpDDMRxInputdBm,
sfpDDMMediaType,
sfpDDMPresence,
sfpDDMIfIndex
}
STATUS current
DESCRIPTION
"SFP DDM parameters group"
::= { nateksMIBGroup 24 }
nateksDigitalIoGroup OBJECT-GROUP
OBJECTS {
ioDInNumber,
dInName,
dInState,
dInNormalState,
dInAlarmSeverity,
dInDescription,
dInTrapEnable,
ioDOutNumber,
dOutName,
dOutState,
dOutNormalState,
dOutAlarmSeverity,
dOutDescription,
dOutTrapEnable
}
STATUS current
DESCRIPTION
"Digital Input/Output managementgroup"
::= { nateksMIBGroup 25 }
nateksStatResetGroup OBJECT-GROUP
OBJECTS {
statReset
}
STATUS current
DESCRIPTION
"Statistics reset group"
::= { nateksMIBGroup 26 }
nateksTlmNotificationGroup NOTIFICATION-GROUP
NOTIFICATIONS { tlmStatusChange }
STATUS current
DESCRIPTION
"TLM status change notification is required if an agent implements TLM table."
::= { nateksMIBGroup 1001 }
nateksAlarmNotificationGroup NOTIFICATION-GROUP
NOTIFICATIONS { alarmValueChange }
STATUS current
DESCRIPTION
"Alarm value change notification is required if an agent implements Alarm table."
::= { nateksMIBGroup 1002 }
nateksTFTPNotificationGroup NOTIFICATION-GROUP
NOTIFICATIONS { tftpStatusChange }
STATUS current
DESCRIPTION
"TFTP software or configuration management requires implementation of this
notification to communicate the status of operation to the management station."
::= { nateksMIBGroup 1003 }
nateksMacFilterNotificationGroup NOTIFICATION-GROUP
NOTIFICATIONS { macFilterViolation }
STATUS current
DESCRIPTION
"Notification about security violations are required if an agent implements MAC filtering."
::= { nateksMIBGroup 1004 }
nateksDigitalIoNotificationGroup NOTIFICATION-GROUP
NOTIFICATIONS { dInStateChange, dOutStateChange }
STATUS current
DESCRIPTION
"Notification about input/output state changes are required if an agent implements digital IO."
::= { nateksMIBGroup 1005 }
nateksMinCompliance MODULE-COMPLIANCE
STATUS current
DESCRIPTION
"Minimal variable set to claim compiance with NATEKS-MIB."
MODULE
MANDATORY-GROUPS { nateksMinimalGroup,
nateksCommonInfoGroup
}
OBJECT systemReset
MIN-ACCESS read-only
DESCRIPTION
"System reset action may be unavailable due to security restrictions."
::= { nateksMIBCompliance 1 }
nateksBasicCompliance MODULE-COMPLIANCE
STATUS current
DESCRIPTION
"Basic variable set to claim compiance with NATEKS-MIB."
MODULE
MANDATORY-GROUPS { nateksMinimalGroup,
nateksCommonExtGroup
}
OBJECT systemReset
MIN-ACCESS read-only
DESCRIPTION
"System reset action may be unavailable due to security restrictions."
OBJECT serialNumber
MIN-ACCESS not-accessible
DESCRIPTION
"serialNumber variable is required by all new agent implementations
but not necessary for legacy agents and for those, where this information
is not available to the agent."
::= { nateksMIBCompliance 2 }
nateksConfigBasicCompliance MODULE-COMPLIANCE
STATUS current
DESCRIPTION
"Basic capabilities of configuration management."
MODULE
MANDATORY-GROUPS { nateksConfigBasicGroup }
::= { nateksMIBCompliance 3 }
nateksConfigConfirmedCompliance MODULE-COMPLIANCE
STATUS current
DESCRIPTION
"Capabilities of configuration management with Apply and Confirm behaviour."
MODULE
MANDATORY-GROUPS { nateksConfigConfirmedGroup }
::= { nateksMIBCompliance 4 }
nateksConfigBackupCompliance MODULE-COMPLIANCE
STATUS current
DESCRIPTION
"Capabilities of local configuration backup management."
MODULE
MANDATORY-GROUPS { nateksConfigBackupGroup }
::= { nateksMIBCompliance 5 }
nateksConfigFullCompliance MODULE-COMPLIANCE
STATUS current
DESCRIPTION
"Basic capabilities of configuration management."
MODULE
MANDATORY-GROUPS { nateksConfigConfirmedGroup,
nateksConfigBackupGroup,
nateksConfigGroupsGroup
}
GROUP nateksConfigRWGroup
DESCRIPTION
"The configRW variable may be not accessible if implementation of
configuration management subsystem of a device can not serialize
configuration to a string of bytes.
The configRW variable may be read-only if writing device configuration
this way can not be supported.
The configRW variable may be not accessible if device configuration
size exceeds internal SNMP PDU size limitations of device's SNMP agent."
::= { nateksMIBCompliance 6 }
nateksG826Compliance MODULE-COMPLIANCE
STATUS current
DESCRIPTION
"G.826 statistics representation and management"
MODULE
MANDATORY-GROUPS { nateksIfG826Group }
OBJECT ifG826EB
MIN-ACCESS not-accessible
DESCRIPTION
"For interfaces, where errors are not reported per block of data received
(like transparent E1), errored blocks counters should be unavailable."
OBJECT ifG826ES
MIN-ACCESS not-accessible
DESCRIPTION
"For interfaces, where errors are not reported per block of data received
(like transparent E1),errored seconds counters should be unavailable."
OBJECT ifG826SES
MIN-ACCESS not-accessible
DESCRIPTION
"For interfaces, where errors are not reported per block of data received
(like transparent E1), severely errored seconds counters should be unavailable."
OBJECT ifG826BBE
MIN-ACCESS not-accessible
DESCRIPTION
"For interfaces, where errors are not reported per block of data received
(like transparent E1), background block errors counters should be unavailable."
::= { nateksMIBCompliance 7 }
nateksIfAlarmCompliance MODULE-COMPLIANCE
STATUS current
DESCRIPTION
"Alarm representation and management"
MODULE
MANDATORY-GROUPS { nateksIfAlarmGroup, nateksAlarmNotificationGroup }
GROUP nateksAlarmGroup
DESCRIPTION
"Implementation for alarmTable is not absolutely required, but members of
it should be included into alarmValueChange notification."
OBJECT alarmId
MIN-ACCESS accessible-for-notify
DESCRIPTION
"In SMIv1 version of MIB alarmId was accessible as read-only. Implementations
can now not implement this variable in table and use it only in notifications."
OBJECT ifAlarmId
MIN-ACCESS accessible-for-notify
DESCRIPTION
"In SMIv1 version of MIB alarmId was accessible as read-only. Implementations
can now not implement this variable in table and use it only in notifications."
OBJECT ifAlarmIfIndex
MIN-ACCESS not-accessible
DESCRIPTION
"In SMIv1 version of MIB alarmId was accessible as read-only. Implementations
can now not implement this variable"
OBJECT alarmTrapEnable
MIN-ACCESS read-only
DESCRIPTION
"If device can not send alarm traps, alarmTrapEnable may be read-only and
indicate 'false'."
::= { nateksMIBCompliance 8 }
nateksTLMCompliance MODULE-COMPLIANCE
STATUS current
DESCRIPTION
"TLM (dry contact inputs) representation and management"
MODULE
MANDATORY-GROUPS { nateksTlmGroup, nateksTlmNotificationGroup }
::= { nateksMIBCompliance 9 }
nateksDSLLTUCompliance MODULE-COMPLIANCE
STATUS current
DESCRIPTION
"DSL information for LTU and NTU DSL units"
MODULE
MANDATORY-GROUPS { nateksDSLGroup,
nateksDSLMultipairGroup,
nateksDSLLTUGroup
}
::= { nateksMIBCompliance 10 }
nateksDSLRegeneratorCompliance MODULE-COMPLIANCE
STATUS current
DESCRIPTION
"DSL information for DSL regenerator/repeater units"
MODULE
MANDATORY-GROUPS { nateksDSLGroup,
nateksDSLMultipairGroup,
nateksDSLRegenerationGroup
}
::= { nateksMIBCompliance 11 }
nateksIndicationCompliance MODULE-COMPLIANCE
STATUS current
DESCRIPTION
"LED status information."
MODULE
MANDATORY-GROUPS { nateksIndicationGroup }
::= { nateksMIBCompliance 12 }
nateksTemperatureCompliance MODULE-COMPLIANCE
STATUS current
DESCRIPTION
"Temperature sensors data."
MODULE
MANDATORY-GROUPS { nateksTemperatureGroup }
::= { nateksMIBCompliance 13 }
nateksTimeCompliance MODULE-COMPLIANCE
STATUS current
DESCRIPTION
"Data from time reference sources."
MODULE
MANDATORY-GROUPS { nateksTimeGroup }
::= { nateksMIBCompliance 14 }
nateksLocalPowerCompliance MODULE-COMPLIANCE
STATUS current
DESCRIPTION
"Local power sources status."
MODULE
MANDATORY-GROUPS { nateksLocalPowerGroup }
::= { nateksMIBCompliance 15 }
nateksTFTPManagementCompliance MODULE-COMPLIANCE
STATUS current
DESCRIPTION
"Software upload and configuration upload/download via TFTP protocol."
MODULE
MANDATORY-GROUPS { nateksTFTPManagementGroup, nateksTFTPNotificationGroup }
::= { nateksMIBCompliance 16 }
nateksMacFilterCompliance MODULE-COMPLIANCE
STATUS current
DESCRIPTION
"MAC-based Ethernet port access control group."
MODULE
MANDATORY-GROUPS { nateksMacFilterGroup, nateksMacFilterNotificationGroup }
::= { nateksMIBCompliance 17 }
nateksSfpDDMGroupCompliance MODULE-COMPLIANCE
STATUS current
DESCRIPTION
"SFP DDM information support."
MODULE
MANDATORY-GROUPS { nateksSfpDDMGroup }
::= { nateksMIBCompliance 18 }
nateksDigitalIoCompliance MODULE-COMPLIANCE
STATUS current
DESCRIPTION
"Digital input/output management support."
MODULE
MANDATORY-GROUPS { nateksDigitalIoGroup, nateksDigitalIoNotificationGroup }
::= { nateksMIBCompliance 19 }
nateksStatResetCompliance MODULE-COMPLIANCE
STATUS current
DESCRIPTION
"Statistics reset support."
MODULE
MANDATORY-GROUPS { nateksStatResetGroup }
::= {nateksMIBCompliance 20 }