NATEKS-MIB DEFINITIONS ::= BEGIN
|
|
|
|
IMPORTS
|
|
MODULE-IDENTITY, OBJECT-TYPE, NOTIFICATION-TYPE, enterprises,
|
|
Gauge32, Integer32, IpAddress, TimeTicks
|
|
FROM SNMPv2-SMI
|
|
OBJECT-GROUP, NOTIFICATION-GROUP, MODULE-COMPLIANCE
|
|
FROM SNMPv2-CONF
|
|
TEXTUAL-CONVENTION, DisplayString, DateAndTime, MacAddress
|
|
FROM SNMPv2-TC
|
|
ifDescr
|
|
FROM RFC1213-MIB
|
|
InterfaceIndex
|
|
FROM IF-MIB;
|
|
|
|
nateks MODULE-IDENTITY
|
|
LAST-UPDATED "201611221200Z"
|
|
ORGANIZATION "Nateks Group"
|
|
CONTACT-INFO
|
|
" Vladimir Gudin
|
|
|
|
Postal: 10A, Vesyolaya str.
|
|
Moscow, 115516
|
|
Russian Federation
|
|
|
|
Tel: +7 499 704 32 32
|
|
|
|
E-mail: gudin@nateks.ru"
|
|
|
|
DESCRIPTION
|
|
"Added statReset to stats branch"
|
|
REVISION "201611221200Z"
|
|
DESCRIPTION
|
|
"Added sfpDDMIfIndex to SfpDDMEntry"
|
|
REVISION "201609151200Z"
|
|
DESCRIPTION
|
|
"This MIB module defines variables and variable groups common
|
|
to more than one type of equipment manufactured by Nateks Group."
|
|
REVISION "201601211200Z"
|
|
DESCRIPTION
|
|
"Added sfpDDMmediaType sfpDDMpresence fields to SfpDDMEntry"
|
|
REVISION "201601201200Z"
|
|
DESCRIPTION
|
|
"Added Digital IO traps and compliance statements"
|
|
REVISION "201503101200Z"
|
|
DESCRIPTION
|
|
"Added Digital IO support"
|
|
REVISION "201411171200Z"
|
|
DESCRIPTION
|
|
"Added SFP DDM support"
|
|
REVISION "201411131200Z"
|
|
DESCRIPTION
|
|
"Added support for FTP operations"
|
|
REVISION "201404161200Z"
|
|
DESCRIPTION
|
|
"Converted from SMIv1 version of NATEKS-MIB v1.2."
|
|
::= { enterprises 4249 }
|
|
|
|
nateksTraps OBJECT IDENTIFIER ::= { nateks 0 }
|
|
nateksProducts OBJECT IDENTIFIER ::= { nateks 1 }
|
|
megatrans3CLTU OBJECT IDENTIFIER ::= { nateksProducts 1 }
|
|
orion2LTU OBJECT IDENTIFIER ::= { nateksProducts 7 }
|
|
megatrans3CRGN OBJECT IDENTIFIER ::= { nateksProducts 8 }
|
|
megatrans4LTU OBJECT IDENTIFIER ::= { nateksProducts 11 }
|
|
megatrans4RGN OBJECT IDENTIFIER ::= { nateksProducts 12 }
|
|
orion3LTU OBJECT IDENTIFIER ::= { nateksProducts 22 }
|
|
orion3NTU OBJECT IDENTIFIER ::= { nateksProducts 23 }
|
|
orion3repeater OBJECT IDENTIFIER ::= { nateksProducts 24 }
|
|
miniFlex OBJECT IDENTIFIER ::= { nateksProducts 26 }
|
|
nateksMgmt OBJECT IDENTIFIER ::= { nateks 2 }
|
|
common OBJECT IDENTIFIER ::= { nateksMgmt 3 }
|
|
config OBJECT IDENTIFIER ::= { nateksMgmt 4 }
|
|
configSystem OBJECT IDENTIFIER ::= { config 100 }
|
|
stats OBJECT IDENTIFIER ::= { nateksMgmt 5 }
|
|
g826 OBJECT IDENTIFIER ::= { stats 1 }
|
|
alarms OBJECT IDENTIFIER ::= { stats 2 }
|
|
tlm OBJECT IDENTIFIER ::= { stats 3 }
|
|
dsl OBJECT IDENTIFIER ::= { stats 4 }
|
|
indication OBJECT IDENTIFIER ::= { stats 5 }
|
|
temperature OBJECT IDENTIFIER ::= { stats 6 }
|
|
time OBJECT IDENTIFIER ::= { stats 7 }
|
|
localPower OBJECT IDENTIFIER ::= { stats 8 }
|
|
sfpDDM OBJECT IDENTIFIER ::= { stats 9 }
|
|
io OBJECT IDENTIFIER ::= { stats 10 }
|
|
ioDIn OBJECT IDENTIFIER ::= { io 1}
|
|
ioDOut OBJECT IDENTIFIER ::= { io 2}
|
|
maintenance OBJECT IDENTIFIER ::= { nateksMgmt 6 }
|
|
tftp OBJECT IDENTIFIER ::= { maintenance 1 }
|
|
nateksSecurity OBJECT IDENTIFIER ::= { nateksMgmt 7 }
|
|
macFilter OBJECT IDENTIFIER ::= { nateksSecurity 1 }
|
|
nateksDev OBJECT IDENTIFIER ::= { nateksMgmt 8 }
|
|
nateksMibInfo OBJECT IDENTIFIER ::= { nateks 3 }
|
|
nateksMIBGroup OBJECT IDENTIFIER ::= { nateksMibInfo 1 }
|
|
nateksMIBCompliance OBJECT IDENTIFIER ::= { nateksMibInfo 2 }
|
|
|
|
|
|
|
|
IntegerNumber ::= TEXTUAL-CONVENTION
|
|
DISPLAY-HINT "d"
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Number of some objects, for example, rows in the table. May
|
|
be zero, if there are no objects or higher if there are some."
|
|
SYNTAX Integer32 (0..2147483647)
|
|
|
|
IntegerIndex ::= TEXTUAL-CONVENTION
|
|
DISPLAY-HINT "d"
|
|
STATUS current
|
|
DESCRIPTION
|
|
"One-based index to the table."
|
|
SYNTAX Integer32 (1..2147483647)
|
|
|
|
IntegerWithDecimal ::= TEXTUAL-CONVENTION
|
|
DISPLAY-HINT "d-1"
|
|
STATUS current
|
|
DESCRIPTION "Fixed-point value with one decimal digit. For example, 250 = 25, -105 = -10.5."
|
|
SYNTAX Integer32
|
|
|
|
IntegerMillis ::= TEXTUAL-CONVENTION
|
|
DISPLAY-HINT "d-3"
|
|
STATUS current
|
|
DESCRIPTION "Fixed-point value with three decimal digits. For example, 25000 = 25, -10500 = -10.5."
|
|
SYNTAX Integer32
|
|
|
|
|
|
systemAlarm OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
no(1),
|
|
nonurgent(2),
|
|
urgent(3),
|
|
urgentAndNonurgent(4)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Device alarm state"
|
|
::= { nateksMgmt 1 }
|
|
|
|
systemReset OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
reset(1),
|
|
readValue(2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Writing reset(1) to maintReset perform a restart of the device.
|
|
Read always returns readValue(2)."
|
|
::= { nateksMgmt 2 }
|
|
|
|
--- common group
|
|
|
|
model OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..255))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Model name, for example MGS-3C-RGN. It is mandatory
|
|
that this only contain printable ASCII characters."
|
|
::= { common 1 }
|
|
|
|
id OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..255))
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Device ID, displayed in the main menu of the module. It is mandatory
|
|
that this only contain printable ASCII characters."
|
|
::= { common 2 }
|
|
|
|
hardwareVersion OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..255))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Version of the device's hardware. For examle: 1.0"
|
|
::= { common 3 }
|
|
|
|
softwareVersion OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..255))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Version of the device's main software and, optionally, versions
|
|
of firmware loaded in DSL chipsets, etc. (if present).
|
|
For examle: 3.5.0.5.9/5.0"
|
|
::= { common 4 }
|
|
|
|
softwareDate OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..10))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Build date of the device's main software in MM.DD.YYYY format.
|
|
Empty string, if build date is not maintained by devices software."
|
|
::= { common 5 }
|
|
|
|
moduleType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
subrack(1),
|
|
standalone(2),
|
|
standaloneSmall(3),
|
|
rackmount(4),
|
|
miniflex(5)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Module type"
|
|
::= { common 6 }
|
|
|
|
subrackAddress OBJECT-TYPE
|
|
SYNTAX Integer32 (0..128)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Address of the module in the FlexGain cassette. For modules that
|
|
do not have such an address, a value of 0 is returned."
|
|
::= { common 7 }
|
|
|
|
errorCode OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Device-dependent error code. Normal value for errorCode is 0,
|
|
i.e. device is fully operational. Any non-zero value indicates
|
|
device hardware fault to management software."
|
|
::= { common 8 }
|
|
|
|
serialNumber OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Device serial number."
|
|
::= { common 9 }
|
|
|
|
|
|
|
|
--- config group
|
|
|
|
configRW OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(0..65535))
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Reading configRW results in reading the whole running config
|
|
(as DUMP R in Megatrans 3C does). Writing configRW results
|
|
in writing to startup config (as LOAD in Megatrans 3C does).
|
|
This variable may be also used by devices, that do not maintain
|
|
configValueTable and configGroupTable, to get/set their
|
|
configuration."
|
|
::= { config 1 }
|
|
|
|
configDefault OBJECT-TYPE
|
|
SYNTAX IntegerNumber
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Writing integer value to configDefault applies
|
|
default profile to the configuration. Values and contents
|
|
of default profiles are device-dependent."
|
|
::= { config 2 }
|
|
|
|
--- config-system group. Is used for configure and read configuration
|
|
--- of Megatrans-3C, 4, 4W, Orion2, Orion3 line of devices.
|
|
|
|
configNumberValues OBJECT-TYPE
|
|
SYNTAX IntegerNumber
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Number of configuration values in device's configuration."
|
|
::= { configSystem 1 }
|
|
|
|
configValueTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF ConfigValueEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A list of configuration values. The number of
|
|
entries is given by the value of configSize."
|
|
::= { configSystem 2 }
|
|
|
|
configValueEntry OBJECT-TYPE
|
|
SYNTAX ConfigValueEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Configuration item."
|
|
INDEX { valueId }
|
|
::= { configValueTable 1 }
|
|
|
|
ConfigValueEntry ::=
|
|
SEQUENCE {
|
|
valueId
|
|
IntegerIndex,
|
|
valueGroup
|
|
IntegerIndex,
|
|
valueName
|
|
DisplayString,
|
|
valueGroupName
|
|
DisplayString,
|
|
valueType
|
|
INTEGER,
|
|
valueStatus
|
|
INTEGER,
|
|
valueStartup
|
|
OCTET STRING,
|
|
valueRunning
|
|
OCTET STRING,
|
|
valueNew
|
|
OCTET STRING,
|
|
valueBackup
|
|
OCTET STRING
|
|
}
|
|
|
|
valueId OBJECT-TYPE
|
|
SYNTAX IntegerIndex (1..2147483647)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A unique index of configuration value. It is constant
|
|
at least until main software of the module changes."
|
|
::= { configValueEntry 1 }
|
|
|
|
valueGroup OBJECT-TYPE
|
|
SYNTAX IntegerIndex
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Index of values' configuration group in the configGroupTable."
|
|
::= { configValueEntry 2 }
|
|
|
|
valueName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A unique name of configuration value. It is constant
|
|
at least until main software of the module changes. Usually,
|
|
it remains constant through the lifecycle of the product."
|
|
::= { configValueEntry 3 }
|
|
|
|
valueGroupName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Name of values' configuration group."
|
|
::= { configValueEntry 4 }
|
|
|
|
valueType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
setNow(1),
|
|
applyConfirm(2),
|
|
afterReset(3)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Value type."
|
|
::= { configValueEntry 5 }
|
|
|
|
valueStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
unchanged(1),
|
|
changed(2),
|
|
applied(3)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Change status for a value.
|
|
|
|
All values of valueType setNow(1) have unchanged(1) status.
|
|
|
|
Status for values of valueType applyConfirm(2):
|
|
Initially, all values have unchanged(1) status.
|
|
When value is changed in new configuration, valueStatus is
|
|
changed(2). When APPLY is made in respect of a value,
|
|
valueStatus is applied(3). When CONFIRM is made for a value,
|
|
valueStatus returns to unchanged(1).
|
|
|
|
Status for values of type afterReset:
|
|
If valueStartup is different from valueRunning, valueStatus
|
|
is changed(2), otherwise unchanged(1)."
|
|
::= { configValueEntry 6 }
|
|
|
|
valueStartup OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(0..65535))
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Startup value of configuration variable. Write operation changes
|
|
valueStartup for values of valueType afterReset(3),
|
|
valueRunning for values of valueType setNow(1),
|
|
valueNew for values of valueType applyConfirm(2)."
|
|
::= { configValueEntry 7 }
|
|
|
|
valueRunning OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(0..65535))
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Running value of configuration variable. Write operation changes
|
|
valueStartup for values of valueType afterReset(3),
|
|
valueRunning for values of valueType setNow(1),
|
|
valueNew for values of valueType applyConfirm(2)."
|
|
::= { configValueEntry 8 }
|
|
|
|
valueNew OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(0..65535))
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"New value of configuration variable. Write operation changes
|
|
valueStartup for values of valueType afterReset(3),
|
|
valueRunning for values of valueType setNow(1),
|
|
valueNew for values of valueType applyConfirm(2)."
|
|
::= { configValueEntry 9 }
|
|
|
|
valueBackup OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(0..65535))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Backup value of configuration variable."
|
|
::= { configValueEntry 10 }
|
|
|
|
configNumberGroups OBJECT-TYPE
|
|
SYNTAX IntegerNumber
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Number of configuration groups in device's configuration."
|
|
::= { configSystem 3 }
|
|
|
|
configGroupTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF ConfigGroupEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A list of configuration values. The number of
|
|
entries is given by the value of configSize."
|
|
::= { configSystem 4 }
|
|
|
|
configGroupEntry OBJECT-TYPE
|
|
SYNTAX ConfigGroupEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Configuration group."
|
|
INDEX { groupId }
|
|
::= { configGroupTable 1 }
|
|
|
|
ConfigGroupEntry ::=
|
|
SEQUENCE {
|
|
groupId
|
|
IntegerIndex,
|
|
groupName
|
|
DisplayString,
|
|
groupType
|
|
INTEGER,
|
|
groupStatus
|
|
INTEGER
|
|
}
|
|
|
|
groupId OBJECT-TYPE
|
|
SYNTAX IntegerIndex (1..2147483647)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A unique index of configuration group. It is constant
|
|
at least until main software of the module changes."
|
|
::= { configGroupEntry 1 }
|
|
|
|
groupName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Name of configuration group. It is constant
|
|
at least until main software of the module changes. Usually,
|
|
it remains constant through the lifecycle of the product."
|
|
::= { configGroupEntry 2 }
|
|
|
|
groupType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
setNow(1),
|
|
applyConfirm(2),
|
|
afterReset(3)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Group type."
|
|
::= { configGroupEntry 3 }
|
|
|
|
groupStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
unchanged(1),
|
|
changed(2),
|
|
applied(3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Change status for a groupvalue.
|
|
|
|
All groups of groupType setNow(1) have unchanged(1) status.
|
|
|
|
Status for groups of groupType applyConfirm(2):
|
|
Initially, all values have unchanged(1) status.
|
|
When some of group values are changed in new configuration,
|
|
groupStatus is changed(2). When APPLY is made for a group,
|
|
groupStatus is applied(3). When CONFIRM is made for a group,
|
|
groupStatus returns to unchanged(1).
|
|
|
|
Status for groups of type afterReset:
|
|
If startup values in the group are different from running
|
|
values, groupStatus is changed(2), otherwise unchanged(1).
|
|
|
|
Writing applied(3) to the groupStatus makes APPLY operation
|
|
on a group. APPLY operation is allowed only for groups of
|
|
groupType applyConfirm(2).
|
|
|
|
Other write operations should report error."
|
|
::= { configGroupEntry 4 }
|
|
|
|
configApplyAll OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
applyAll(1),
|
|
readValue(2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Writing applyAll(1) to configApplyAll makes APPLY ALL operation.
|
|
Read always returns readValue(2)."
|
|
::= { configSystem 5 }
|
|
|
|
configConfirm OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
confirm(1),
|
|
readValue(2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Writing confirm(1) to configConfirm makes CONFIRM operation.
|
|
Read always returns readValue(2)."
|
|
::= { configSystem 6 }
|
|
|
|
configBackup OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
backup(1),
|
|
readValue(2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Writing backup(1) to configBackup performs BACKUP operation.
|
|
Read always returns readValue(2)."
|
|
::= { configSystem 7 }
|
|
|
|
configRestore OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
restore(1),
|
|
readValue(2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Writing restore(1) to configRestore performs RESTORE operation.
|
|
Read always returns readValue(2)."
|
|
::= { configSystem 8 }
|
|
|
|
|
|
|
|
--- stats group
|
|
|
|
--- g826 group
|
|
|
|
g826Number OBJECT-TYPE
|
|
SYNTAX IntegerNumber
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Number of g826 statistics."
|
|
::= { g826 1 }
|
|
|
|
g826Table OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF G826Entry
|
|
MAX-ACCESS not-accessible
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"A list of g826 statistics. Each consists of an interface index
|
|
in interfaces table, statistics name and g826 statistics valuess."
|
|
::= { g826 2 }
|
|
|
|
g826Entry OBJECT-TYPE
|
|
SYNTAX G826Entry
|
|
MAX-ACCESS not-accessible
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"G826 statistics."
|
|
INDEX { g826Id }
|
|
::= { g826Table 1 }
|
|
|
|
G826Entry ::=
|
|
SEQUENCE {
|
|
g826Id
|
|
IntegerIndex,
|
|
g826IfIndex
|
|
InterfaceIndex,
|
|
g826Name
|
|
DisplayString,
|
|
g826EB
|
|
Gauge32,
|
|
g826ES
|
|
Gauge32,
|
|
g826SES
|
|
Gauge32,
|
|
g826BBE
|
|
Gauge32,
|
|
g826AvailableTime
|
|
Gauge32,
|
|
g826UnavailableTime
|
|
Gauge32,
|
|
g826StatReset
|
|
INTEGER
|
|
}
|
|
|
|
g826Id OBJECT-TYPE
|
|
SYNTAX IntegerIndex (1..2147483647)
|
|
MAX-ACCESS not-accessible
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"A unique index of this g826 statistics. It is constant
|
|
at least between device reboots."
|
|
::= { g826Entry 1 }
|
|
|
|
g826IfIndex OBJECT-TYPE
|
|
SYNTAX InterfaceIndex
|
|
MAX-ACCESS read-only
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"Index of interface in interfaces table, this g826
|
|
statistics is for."
|
|
::= { g826Entry 2 }
|
|
|
|
g826Name OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"Name of the statistic, for example: E1-1-CRC4, E1-2-E-Bit."
|
|
::= { g826Entry 3 }
|
|
|
|
g826EB OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"Number of errored blocks."
|
|
::= { g826Entry 4 }
|
|
|
|
g826ES OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
UNITS "s"
|
|
MAX-ACCESS read-only
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"Number of errored seconds."
|
|
::= { g826Entry 5 }
|
|
|
|
g826SES OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
UNITS "s"
|
|
MAX-ACCESS read-only
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"Number of severely errored seconds."
|
|
::= { g826Entry 6 }
|
|
|
|
g826BBE OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"Number of background block errors."
|
|
::= { g826Entry 7 }
|
|
|
|
g826AvailableTime OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
UNITS "s"
|
|
MAX-ACCESS read-only
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"Available time in seconds."
|
|
::= { g826Entry 8 }
|
|
|
|
g826UnavailableTime OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
UNITS "s"
|
|
MAX-ACCESS read-only
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"Unavailable time in seconds."
|
|
::= { g826Entry 9 }
|
|
|
|
g826StatReset OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
reset(1),
|
|
readValue(2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"Writing reset(1) to g826StatReset restarts this g826 statistic.
|
|
Read always returns readValue(2)."
|
|
::= { g826Entry 10 }
|
|
|
|
g826Reset OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
reset(1),
|
|
readValue(2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Writing reset(1) to g826Reset restarts all g826 statistics.
|
|
Read always returns readValue(2)."
|
|
::= { g826 3 }
|
|
|
|
-- NATEKS-MIB v0.9 and earlier versions contained a typo: g826Reset
|
|
-- was called g286Reset. This string maintains backward compatibility.
|
|
-- g286Reset OBJECT IDENTIFIER ::= { g826 3 }
|
|
|
|
|
|
ifG826Table OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF IfG826Entry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A list of g826 statistics. Each consists of an interface index
|
|
in interfaces table, statistics name and g826 statistics valuess."
|
|
::= { g826 4 }
|
|
|
|
ifG826Entry OBJECT-TYPE
|
|
SYNTAX IfG826Entry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"G826 statistics grouped by interface."
|
|
INDEX { ifG826IfIndex, ifG826Id }
|
|
::= { ifG826Table 1 }
|
|
|
|
IfG826Entry ::=
|
|
SEQUENCE {
|
|
ifG826Id
|
|
IntegerIndex,
|
|
ifG826IfIndex
|
|
InterfaceIndex,
|
|
ifG826Name
|
|
DisplayString,
|
|
ifG826EB
|
|
Gauge32,
|
|
ifG826ES
|
|
Gauge32,
|
|
ifG826SES
|
|
Gauge32,
|
|
ifG826BBE
|
|
Gauge32,
|
|
ifG826AvailableTime
|
|
Gauge32,
|
|
ifG826UnavailableTime
|
|
Gauge32,
|
|
ifG826StatReset
|
|
INTEGER
|
|
}
|
|
|
|
ifG826Id OBJECT-TYPE
|
|
SYNTAX IntegerIndex (1..2147483647)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A unique index of this g826 statistics. It is constant
|
|
at least between device reboots."
|
|
::= { ifG826Entry 1 }
|
|
|
|
ifG826IfIndex OBJECT-TYPE
|
|
SYNTAX InterfaceIndex(1..2147483647)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Index of interface in interfaces table, this g826
|
|
statistics is for."
|
|
::= { ifG826Entry 2 }
|
|
|
|
ifG826Name OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Name of the statistic, for example: E1-1-CRC4, E1-2-E-Bit."
|
|
::= { ifG826Entry 3 }
|
|
|
|
ifG826EB OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Number of errored blocks."
|
|
::= { ifG826Entry 4 }
|
|
|
|
ifG826ES OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
UNITS "s"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Number of errored seconds."
|
|
::= { ifG826Entry 5 }
|
|
|
|
ifG826SES OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
UNITS "s"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Number of severely errored seconds."
|
|
::= { ifG826Entry 6 }
|
|
|
|
ifG826BBE OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Number of background block errors."
|
|
::= { ifG826Entry 7 }
|
|
|
|
ifG826AvailableTime OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
UNITS "s"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Available time in seconds."
|
|
::= { ifG826Entry 8 }
|
|
|
|
ifG826UnavailableTime OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
UNITS "s"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Unavailable time in seconds."
|
|
::= { ifG826Entry 9 }
|
|
|
|
ifG826StatReset OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
reset(1),
|
|
readValue(2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Writing reset(1) to ifG826StatReset restarts this g826 statistic.
|
|
Read always returns readValue(2)."
|
|
::= { ifG826Entry 10 }
|
|
|
|
|
|
|
|
--- alarm group
|
|
|
|
alarmNumber OBJECT-TYPE
|
|
SYNTAX IntegerNumber
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Number of alarms."
|
|
::= { alarms 1 }
|
|
|
|
alarmTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF AlarmEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A list of alarms. Each consists of an interface index
|
|
in interfaces table, alarm name, value and cutoff information."
|
|
::= { alarms 2 }
|
|
|
|
alarmEntry OBJECT-TYPE
|
|
SYNTAX AlarmEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Alarms."
|
|
INDEX { alarmId }
|
|
::= { alarmTable 1 }
|
|
|
|
AlarmEntry ::=
|
|
SEQUENCE {
|
|
alarmId
|
|
IntegerIndex,
|
|
alarmIfIndex
|
|
InterfaceIndex,
|
|
alarmName
|
|
DisplayString,
|
|
alarmValue
|
|
INTEGER,
|
|
alarmCutoff
|
|
INTEGER,
|
|
alarmType
|
|
BITS,
|
|
alarmDisplayType
|
|
INTEGER
|
|
}
|
|
|
|
alarmId OBJECT-TYPE
|
|
SYNTAX IntegerIndex (1..2147483647)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A unique index of alarm. It is constant
|
|
at least between device reboots."
|
|
::= { alarmEntry 1 }
|
|
|
|
alarmIfIndex OBJECT-TYPE
|
|
SYNTAX InterfaceIndex
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Index of interface in interfaces table, which state this
|
|
alarm indicates. Alarms, that do not have associated interfaces
|
|
(for example, maintenance alarms), should have index
|
|
of management interface as alarmIfIndex."
|
|
::= { alarmEntry 2 }
|
|
|
|
alarmName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Name of the alarm, for example: LOS-S, BER-H."
|
|
::= { alarmEntry 3 }
|
|
|
|
alarmValue OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
on(1),
|
|
off(2)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Alarm status."
|
|
::= { alarmEntry 4 }
|
|
|
|
alarmCutoff OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
on(1),
|
|
off(2)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Alarm cutoff status."
|
|
::= { alarmEntry 5 }
|
|
|
|
alarmType OBJECT-TYPE
|
|
SYNTAX BITS {
|
|
localMajor(0),
|
|
localMinor(1),
|
|
remoteMajor(2),
|
|
remoteMinor(3),
|
|
maintenance(4)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Alarm type. If none of alarm types is applicable to this
|
|
alarm, all bits are zero."
|
|
::= { alarmEntry 6 }
|
|
|
|
alarmDisplayType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
major(1),
|
|
minor(2),
|
|
maintenance(3)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Simplified alarm type to be used in trap filters"
|
|
::= { alarmEntry 7 }
|
|
|
|
alarmTrapEnable OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
true(1),
|
|
false(2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Alarm trap generation setup: changes in alarm state will cause trap
|
|
generation when the alarmTrapEnable is true."
|
|
::= { alarms 3 }
|
|
|
|
--- same alarms, but grouped by interface
|
|
|
|
ifAlarmTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF IfAlarmEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A two-dimentional array of alarms. Alarms are grouped by interface number."
|
|
::= { alarms 4 }
|
|
|
|
ifAlarmEntry OBJECT-TYPE
|
|
SYNTAX IfAlarmEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Alarms grouped by interface."
|
|
INDEX { ifAlarmIfIndex, ifAlarmId }
|
|
::= { ifAlarmTable 1 }
|
|
|
|
IfAlarmEntry ::=
|
|
SEQUENCE {
|
|
ifAlarmId
|
|
IntegerIndex,
|
|
ifAlarmIfIndex
|
|
InterfaceIndex,
|
|
ifAlarmName
|
|
DisplayString,
|
|
ifAlarmValue
|
|
INTEGER,
|
|
ifAlarmCutoff
|
|
INTEGER,
|
|
ifAlarmType
|
|
BITS,
|
|
ifAlarmDisplayType
|
|
INTEGER
|
|
}
|
|
|
|
ifAlarmId OBJECT-TYPE
|
|
SYNTAX IntegerIndex (1..2147483647)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A unique index of alarm within interface. It is constant
|
|
at least between device reboots."
|
|
::= { ifAlarmEntry 1 }
|
|
|
|
ifAlarmIfIndex OBJECT-TYPE
|
|
SYNTAX InterfaceIndex (1..2147483647)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Index of interface in interfaces table, which state this
|
|
alarm indicates. Alarms, that do not have associated interfaces
|
|
(for example, maintenance alarms), should have index
|
|
of management interface as alarmIfIndex."
|
|
::= { ifAlarmEntry 2 }
|
|
|
|
ifAlarmName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Name of the alarm, for example: LOS-S, BER-H."
|
|
::= { ifAlarmEntry 3 }
|
|
|
|
ifAlarmValue OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
on(1),
|
|
off(2)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Alarm status."
|
|
::= { ifAlarmEntry 4 }
|
|
|
|
ifAlarmCutoff OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
on(1),
|
|
off(2)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Alarm cutoff status."
|
|
::= { ifAlarmEntry 5 }
|
|
|
|
ifAlarmType OBJECT-TYPE
|
|
SYNTAX BITS {
|
|
localMajor(0),
|
|
localMinor(1),
|
|
remoteMajor(2),
|
|
remoteMinor(3),
|
|
maintenance(4)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Alarm type. If none of alarm types is applicable to this
|
|
alarm, all bits are zero."
|
|
::= { ifAlarmEntry 6 }
|
|
|
|
ifAlarmDisplayType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
major(1),
|
|
minor(2),
|
|
maintenance(3)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Simplified alarm type to be used in trap filters"
|
|
::= { ifAlarmEntry 7 }
|
|
|
|
|
|
|
|
|
|
--- tlm group
|
|
|
|
tlmNumber OBJECT-TYPE
|
|
SYNTAX IntegerNumber
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Number of tlm contacts."
|
|
::= { tlm 1 }
|
|
|
|
tlmTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF TlmEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A list of tlms. Each consists of tlm name, setup and status
|
|
information, and trap generation setup."
|
|
::= { tlm 2 }
|
|
|
|
tlmEntry OBJECT-TYPE
|
|
SYNTAX TlmEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"TLM"
|
|
INDEX { tlmId }
|
|
::= { tlmTable 1 }
|
|
|
|
TlmEntry ::=
|
|
SEQUENCE {
|
|
tlmId
|
|
IntegerIndex,
|
|
tlmName
|
|
DisplayString,
|
|
tlmStatus
|
|
INTEGER,
|
|
tlmLastStatusChange
|
|
TimeTicks,
|
|
tlmSetup
|
|
INTEGER,
|
|
tlmTrapEnable
|
|
INTEGER
|
|
}
|
|
|
|
tlmId OBJECT-TYPE
|
|
SYNTAX IntegerIndex (1..2147483647)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A unique index of TLM. It is constant
|
|
at least between device reboots."
|
|
::= { tlmEntry 1 }
|
|
|
|
tlmName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Name of the TLM."
|
|
::= { tlmEntry 2 }
|
|
|
|
tlmStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
on(1),
|
|
off(2),
|
|
det(3)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The status of the TLM: on, off or detected."
|
|
::= { tlmEntry 3 }
|
|
|
|
tlmLastStatusChange OBJECT-TYPE
|
|
SYNTAX TimeTicks
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The time of last TLM status change, counted from system start."
|
|
::= { tlmEntry 4 }
|
|
|
|
tlmSetup OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
normalOpen(1),
|
|
normalClosed(2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"TLM setup: normally open or normally closed.
|
|
Writing to this variable will configure this TLM, if the device
|
|
does support the write access to this variable."
|
|
::= { tlmEntry 5 }
|
|
|
|
tlmTrapEnable OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
true(1),
|
|
false(2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"TLM trap generation setup: changes in TLM status will cause trap
|
|
generation when the tlmTrapEnable is true."
|
|
::= { tlmEntry 6 }
|
|
|
|
tlmClear OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
reset(1),
|
|
readValue(2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Writing reset(1) to tlmClear will clear the TLM history,
|
|
and det state of all TLM indicators will become off state.
|
|
Read always returns readValue(2)."
|
|
::= { tlm 3 }
|
|
|
|
|
|
--- dsl group
|
|
|
|
dslChannelNumber OBJECT-TYPE
|
|
SYNTAX IntegerNumber
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Number of dsl channels."
|
|
::= { dsl 1 }
|
|
|
|
dslUnitType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
modem(1),
|
|
regenerator(2)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The type of the unit: line termination units (LTU) and
|
|
network termination units (NTU) will have the modem(1) value.
|
|
All types of regenerators have regenerator(2) value."
|
|
::= { dsl 2 }
|
|
|
|
dslChannelTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF DslChannelEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A list of DSL channels present on this device. Each consists of DSL index, ifIndex, setup and status
|
|
information."
|
|
::= { dsl 3 }
|
|
|
|
dslChannelEntry OBJECT-TYPE
|
|
SYNTAX DslChannelEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"DSL channel"
|
|
INDEX { dslChannelId }
|
|
::= { dslChannelTable 1 }
|
|
|
|
DslChannelEntry ::=
|
|
SEQUENCE {
|
|
dslChannelId
|
|
IntegerIndex,
|
|
dslChannelIfIndex
|
|
InterfaceIndex,
|
|
dslChannelMode --- Master/Slave
|
|
INTEGER,
|
|
dslChannelStandard --- G.shdsl, G.shdsl.bis, etc.
|
|
INTEGER,
|
|
dslChannelClockReference --- 1, 2, 3a, 3b
|
|
INTEGER,
|
|
dslChannelLineCodeConfig --- PAM configuration
|
|
INTEGER,
|
|
dslChannelPSDConfig --- Annex configuration
|
|
INTEGER,
|
|
dslChannelBaserateConfig --- Baserate configuration
|
|
Integer32,
|
|
dslChannelStatus --- Link up, link down, training
|
|
INTEGER,
|
|
dslChannelLineCode --- PAM status
|
|
INTEGER,
|
|
dslChannelPSD --- Annex status
|
|
INTEGER,
|
|
dslChannelBaserate --- Baserate status
|
|
Integer32,
|
|
dslChannelLineRate --- Line rate = Baserate*64k + 8k
|
|
Integer32,
|
|
dslChannelPayloadRate --- Payload rate = Baserate*64k
|
|
Integer32,
|
|
dslChannelNMR
|
|
Integer32,
|
|
dslChannelPowerBackoff
|
|
Integer32,
|
|
dslChannelFarEndPowerBackoff
|
|
Integer32,
|
|
dslChannelLoopAttenuation
|
|
Integer32,
|
|
dslChannelEOCNumber
|
|
IntegerIndex,
|
|
--- For NTU/LTU only
|
|
dslChannelRegeneratorNumber
|
|
IntegerNumber,
|
|
dslChannelRemotePower --- Remote power supply status
|
|
INTEGER,
|
|
dslChannelRemotePowerVoltage --- Remote power voltage
|
|
Integer32
|
|
}
|
|
|
|
dslChannelId OBJECT-TYPE
|
|
SYNTAX IntegerIndex (1..2147483647)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A unique index of the DSL channel. It is constant for a given model."
|
|
::= { dslChannelEntry 1 }
|
|
|
|
dslChannelIfIndex OBJECT-TYPE
|
|
SYNTAX InterfaceIndex
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Index in interfaces table of this DSL channel."
|
|
::= { dslChannelEntry 2 }
|
|
|
|
dslChannelMode OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
master(1),
|
|
slave(2)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The activation mode of this channel: either it is Master (xU-C) or Slave (xU-R)."
|
|
::= { dslChannelEntry 3 }
|
|
|
|
dslChannelStandard OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
gshdsl(1),
|
|
gshdslBis(2),
|
|
gshdslExt(3)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The G.Shdsl mode this channel is working in."
|
|
::= { dslChannelEntry 4 }
|
|
|
|
dslChannelClockReference OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
clockMode1(1),
|
|
clockMode2(2),
|
|
clockMode3a(3),
|
|
clockMode3b(4)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The G.Shdsl clock mode this channel is working in."
|
|
::= { dslChannelEntry 5 }
|
|
|
|
dslChannelLineCodeConfig OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
auto(1),
|
|
pam4(2),
|
|
pam8(3),
|
|
pam16(4),
|
|
pam32(5),
|
|
pam64(6),
|
|
pam128(7)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The configured line code of this channel."
|
|
::= { dslChannelEntry 6 }
|
|
|
|
dslChannelPSDConfig OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
annexA(1),
|
|
annexB(2),
|
|
annexAB(3)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The configured PSD mask (annex) of this channel."
|
|
::= { dslChannelEntry 7 }
|
|
|
|
dslChannelBaserateConfig OBJECT-TYPE
|
|
SYNTAX Integer32 (0..1024)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The configured base data rate (in 64kbit/s units) of this channel. 0 means auto."
|
|
::= { dslChannelEntry 8 }
|
|
|
|
dslChannelStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
down(1),
|
|
preactivation(2),
|
|
activation(3),
|
|
up(4)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The activation status of this DSL channel."
|
|
::= { dslChannelEntry 9 }
|
|
|
|
dslChannelLineCode OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
notAvailable(0),
|
|
pam4(2),
|
|
pam8(3),
|
|
pam16(4),
|
|
pam32(5),
|
|
pam64(6),
|
|
pam128(7)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Current working line code of this channel. If the link is down, this item
|
|
has notAvailable(0) value."
|
|
::= { dslChannelEntry 10 }
|
|
|
|
dslChannelPSD OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
notAvailable(0),
|
|
annexA(1),
|
|
annexB(2),
|
|
annexAB(3)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Current working PSD mask (annex) of this channel. If the link is down, this item
|
|
has notAvailable(0) value."
|
|
::= { dslChannelEntry 11 }
|
|
|
|
dslChannelBaserate OBJECT-TYPE
|
|
SYNTAX Integer32(0..1024)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Current working base data rate (in 64kbit/s units) of this channel. If the link is down, this item has 0 value."
|
|
::= { dslChannelEntry 12 }
|
|
|
|
dslChannelLineRate OBJECT-TYPE
|
|
SYNTAX Integer32(0..65536)
|
|
UNITS "kbps"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Current working line rate in kbit/s of this channel. If the link is down, this item has 0 value."
|
|
::= { dslChannelEntry 13 }
|
|
|
|
dslChannelPayloadRate OBJECT-TYPE
|
|
SYNTAX Integer32(0..65536)
|
|
UNITS "kbps"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Current working payload rate in kbit/s of this channel. If the link is down, this item has 0 value."
|
|
::= { dslChannelEntry 14 }
|
|
|
|
dslChannelNMR OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "dB"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Current noise margin rate for the DSL channel in dB."
|
|
::= { dslChannelEntry 15 }
|
|
|
|
dslChannelPowerBackoff OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "dB"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Current power backoff of the local side of the DSL channel in dB."
|
|
::= { dslChannelEntry 16 }
|
|
|
|
dslChannelFarEndPowerBackoff OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "dB"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Current far end power backoff of the DSL channel in dB."
|
|
::= { dslChannelEntry 17 }
|
|
|
|
dslChannelLoopAttenuation OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "dB"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Current loop attenuation of the DSL channel in dB."
|
|
::= { dslChannelEntry 18 }
|
|
|
|
dslChannelEOCNumber OBJECT-TYPE
|
|
SYNTAX IntegerIndex (1..2147483647)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The EOC number of the unit in this DSL link.
|
|
xtuC 1
|
|
xtuR 2
|
|
repeater N=1..max N+2"
|
|
::= { dslChannelEntry 19 }
|
|
|
|
dslChannelRegeneratorNumber OBJECT-TYPE
|
|
SYNTAX IntegerNumber
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of regenerators in the link.
|
|
This unit is not present on regenerators."
|
|
::= { dslChannelEntry 20 }
|
|
|
|
dslChannelRemotePower OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
on(1),
|
|
off(2),
|
|
alarm(3)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The remote power status of the channel.
|
|
This item is not present on regenerators. On devices without remote powering capability it
|
|
is present and always shows off(2).
|
|
|
|
on(1) means the remote power is turned on in configuration and remote power in turned on.
|
|
|
|
off(2) means the remote power is turned off in configuration or remote power capability is
|
|
not present in the device.
|
|
|
|
alarm(3) means remote power is turned off for a certain amount of time because overcurrent
|
|
protection has triggered or AC/DC leakage threshold was met."
|
|
::= { dslChannelEntry 21 }
|
|
|
|
dslChannelRemotePowerVoltage OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Remote power voltage configuration for the channel.
|
|
This item is not present on regenerators.
|
|
On devices without remote powering capability it is present and always shows 0.
|
|
If remote power is turned off for this channel in configuration, 0 is read from this item.
|
|
If remote power is turned on for this channel in configuration, remote power nominal voltage
|
|
is read from this item regardless of error status (it may be off due to overcurrent etc).
|
|
|
|
This item appeared in MIB v0.9 and some devices may not support it."
|
|
::= { dslChannelEntry 22 }
|
|
|
|
dslGroupNumber OBJECT-TYPE
|
|
SYNTAX IntegerNumber
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of multiwire groups."
|
|
::= { dsl 4 }
|
|
|
|
dslGroupTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF DslGroupEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This table contains information on multipair and 4-wire goups of DSL channels."
|
|
::= { dsl 5 }
|
|
|
|
dslGroupEntry OBJECT-TYPE
|
|
SYNTAX DslGroupEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"DSL multipair of 4-wire group"
|
|
INDEX { dslGroupId }
|
|
::= { dslGroupTable 1 }
|
|
|
|
DslGroupEntry ::=
|
|
SEQUENCE {
|
|
dslGroupId
|
|
IntegerIndex,
|
|
dslGroupType
|
|
INTEGER,
|
|
dslGroupMainChannel
|
|
IntegerIndex,
|
|
dslGroupChannel1
|
|
IntegerIndex,
|
|
dslGroupChannel2
|
|
IntegerIndex,
|
|
dslGroupChannel3
|
|
IntegerIndex,
|
|
dslGroupChannel4
|
|
IntegerIndex
|
|
}
|
|
|
|
dslGroupId OBJECT-TYPE
|
|
SYNTAX IntegerIndex (1..2147483647)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A unique index of the DSL channel group. It is constant between changes of unit configuration."
|
|
::= { dslGroupEntry 1 }
|
|
|
|
dslGroupType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
type4wire(1),
|
|
type2pair(2),
|
|
type3pair(3),
|
|
type4pair(4)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The type of channel grouping.
|
|
type4wire(1) represent 4-wire method of channel aggregation.
|
|
type2pair(2)-type4pair(4) represent the M-pair method of channel aggregation."
|
|
::= { dslGroupEntry 2 }
|
|
|
|
dslGroupMainChannel OBJECT-TYPE
|
|
SYNTAX IntegerIndex
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This is the dslChannelId of the main channel in the multipair or 4-wire group.
|
|
The configuration for all channels in the group is taken from the main channel.
|
|
Only the main channel is mentioned in regenerator pairs when regenerator is
|
|
working in multipair mode."
|
|
::= { dslGroupEntry 3 }
|
|
|
|
dslGroupChannel1 OBJECT-TYPE
|
|
SYNTAX IntegerIndex
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The first channel in the sequence of dslChannelId's of the channels in the
|
|
multipair or 4-wire group. The main channel is mentioned amongst others."
|
|
::= { dslGroupEntry 4 }
|
|
|
|
dslGroupChannel2 OBJECT-TYPE
|
|
SYNTAX IntegerIndex
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The second channel in the sequence of dslChannelId's of the channels in the
|
|
multipair or 4-wire group. The main channel is mentioned amongst others."
|
|
::= { dslGroupEntry 5 }
|
|
|
|
dslGroupChannel3 OBJECT-TYPE
|
|
SYNTAX IntegerIndex
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The third channel in the sequence of dslChannelId's of the channels in the
|
|
multipair or 4-wire group. The main channel is mentioned amongst others.
|
|
Only present for 3-pair and 4-pair groups."
|
|
::= { dslGroupEntry 6 }
|
|
|
|
dslGroupChannel4 OBJECT-TYPE
|
|
SYNTAX IntegerIndex
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The fourth channel in the sequence of dslChannelId's of the channels in the
|
|
multipair or 4-wire group. The main channel is mentioned amongst others.
|
|
Only present for 4-pair groups."
|
|
::= { dslGroupEntry 7 }
|
|
|
|
dslRegenerationChannels OBJECT-TYPE
|
|
SYNTAX IntegerNumber
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of regenerator channels working in this device."
|
|
::= { dsl 6 }
|
|
|
|
dslRegenerationTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF DslRegenerationEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This table is a list of regenerator channels working in this device.
|
|
Devices that do not have regenerator functions do not need to implement this table."
|
|
::= { dsl 7 }
|
|
|
|
dslRegenerationEntry OBJECT-TYPE
|
|
SYNTAX DslRegenerationEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Regeneration channel"
|
|
INDEX { dslRegenerationId }
|
|
::= { dslRegenerationTable 1 }
|
|
|
|
DslRegenerationEntry ::=
|
|
SEQUENCE {
|
|
dslRegenerationId
|
|
IntegerIndex,
|
|
dslRegenerationSide1
|
|
IntegerIndex,
|
|
dslRegenerationSide2
|
|
IntegerIndex
|
|
}
|
|
|
|
dslRegenerationId OBJECT-TYPE
|
|
SYNTAX IntegerIndex (1..2147483647)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A unique index of the DSL regeneration channel. It is constant between configuration changes."
|
|
::= { dslRegenerationEntry 1 }
|
|
|
|
dslRegenerationSide1 OBJECT-TYPE
|
|
SYNTAX IntegerIndex
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This is the dslChannelId of side 1 of the regeneration channel."
|
|
::= { dslRegenerationEntry 2 }
|
|
|
|
dslRegenerationSide2 OBJECT-TYPE
|
|
SYNTAX IntegerIndex
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This is the dslChannelId of side 2 of the regeneration channel."
|
|
::= { dslRegenerationEntry 3 }
|
|
|
|
|
|
--- indication group
|
|
|
|
indicationLedNumber OBJECT-TYPE
|
|
SYNTAX IntegerNumber
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Number of LED indicators the device has."
|
|
::= { indication 1 }
|
|
|
|
indicationLedTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF IndicationLedEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A list LED indicators. Each consists of an LED index, textual description,
|
|
populated/not populated status, current color and blinking rate."
|
|
::= { indication 2 }
|
|
|
|
indicationLedEntry OBJECT-TYPE
|
|
SYNTAX IndicationLedEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"LED inidicators."
|
|
INDEX { indicationLedId }
|
|
::= { indicationLedTable 1 }
|
|
|
|
IndicationLedEntry ::=
|
|
SEQUENCE {
|
|
indicationLedId
|
|
IntegerIndex,
|
|
indicationLedDescription
|
|
DisplayString,
|
|
indicationLedState
|
|
INTEGER,
|
|
indicationLedFlash
|
|
INTEGER
|
|
}
|
|
|
|
indicationLedId OBJECT-TYPE
|
|
SYNTAX IntegerIndex (1..2147483647)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A unique index of the LED indicator. It is constant between
|
|
different models of one device family."
|
|
::= { indicationLedEntry 1 }
|
|
|
|
|
|
indicationLedDescription OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Description of LED indicator. May include name on the front/back panel
|
|
of the device and/or place of the LED."
|
|
::= { indicationLedEntry 2 }
|
|
|
|
indicationLedState OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
notPopulated(0),
|
|
off(1),
|
|
red(2),
|
|
yellow(3),
|
|
green(4),
|
|
cyan(5),
|
|
blue(6),
|
|
magenta(7),
|
|
white(8)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The state of a LED. If the LED is not present, it's state is not-populated.
|
|
If it is not lit, it's state is OFF. If it is lit, then a color is reported."
|
|
::= { indicationLedEntry 3 }
|
|
|
|
indicationLedFlash OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
notPopulated(0),
|
|
blink1000(1),
|
|
blink0100(2),
|
|
blink1100(3),
|
|
blink0010(4),
|
|
blink1010(5),
|
|
blink0110(6),
|
|
blink1110(7),
|
|
blink0001(8),
|
|
blink1001(9),
|
|
blink0101(10),
|
|
blink1101(11),
|
|
blink0011(12),
|
|
blink1011(13),
|
|
blink0111(14),
|
|
constant(15)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"If the LED is switching on and off at a constant rate, shows how is it blinking.
|
|
Values from 1 to 14 represent a bit mask, where each bit shows, if the LED is lit during
|
|
corresponding quarter of second: bit 0 - first quarter, bit 1 - second etc.
|
|
If the LED is lit constantly, returns 'constant(15)'."
|
|
::= { indicationLedEntry 4 }
|
|
|
|
|
|
--- temperature group
|
|
|
|
temperatureSensorNumber OBJECT-TYPE
|
|
SYNTAX IntegerNumber
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Number of the temperature sensors the device has."
|
|
::= { temperature 1 }
|
|
|
|
temperatureSensorTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF TemperatureSensorEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A list temperature sensors. First sensor in the list should always
|
|
be the sensor that can be considered as 'Board temperature' sensor.
|
|
For each sensor there is an identifier, description and the temperature
|
|
value in 1/1000 of the Celcium degree."
|
|
::= { temperature 2 }
|
|
|
|
temperatureSensorEntry OBJECT-TYPE
|
|
SYNTAX TemperatureSensorEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Temperature sensors."
|
|
INDEX { temperatureSensorId }
|
|
::= { temperatureSensorTable 1 }
|
|
|
|
TemperatureSensorEntry ::=
|
|
SEQUENCE {
|
|
temperatureSensorId
|
|
IntegerIndex,
|
|
temperatureSensorDescription
|
|
DisplayString,
|
|
temperatureSensorValue
|
|
IntegerMillis
|
|
}
|
|
|
|
temperatureSensorId OBJECT-TYPE
|
|
SYNTAX IntegerIndex (1..2147483647)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A unique index of the temperature sensor. It is constant between
|
|
different models of one device family."
|
|
::= { temperatureSensorEntry 1 }
|
|
|
|
temperatureSensorDescription OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Description of the temperature sensor. Should describe, where temperature is measured."
|
|
::= { temperatureSensorEntry 2 }
|
|
|
|
temperatureSensorValue OBJECT-TYPE
|
|
SYNTAX IntegerMillis
|
|
UNITS "C"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The temperature value in 1/1000 of the Celcium degree. For example, 25000 = 25C, -10500 = -10.5C."
|
|
::= { temperatureSensorEntry 3 }
|
|
|
|
|
|
|
|
--- time group
|
|
|
|
timeSourceNumber OBJECT-TYPE
|
|
SYNTAX IntegerNumber
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Number of device's UTC time sources."
|
|
::= { time 1 }
|
|
|
|
timeSourceTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF TimeSourceEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Table of UTC time sources present on device. Examples are UTC,
|
|
satellite (GNSS) etc."
|
|
::= { time 2 }
|
|
|
|
timeSourceEntry OBJECT-TYPE
|
|
SYNTAX TimeSourceEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Time source."
|
|
INDEX { timeSourceId }
|
|
::= { timeSourceTable 1 }
|
|
|
|
TimeSourceEntry ::=
|
|
SEQUENCE {
|
|
timeSourceId
|
|
IntegerIndex,
|
|
timeSourceName
|
|
DisplayString,
|
|
timeSourceStratum
|
|
Integer32,
|
|
timeSourceValue
|
|
DateAndTime
|
|
}
|
|
|
|
timeSourceId OBJECT-TYPE
|
|
SYNTAX IntegerIndex (1..2147483647)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A unique index of the time source. It is constant between
|
|
reconfigurations of a device."
|
|
::= { timeSourceEntry 1 }
|
|
|
|
|
|
timeSourceName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Name of the time source. For example: NTP."
|
|
::= { timeSourceEntry 2 }
|
|
|
|
timeSourceStratum OBJECT-TYPE
|
|
SYNTAX Integer32 (1..16)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Clock source stratum as it is defined in NTP."
|
|
::= { timeSourceEntry 3 }
|
|
|
|
timeSourceValue OBJECT-TYPE
|
|
SYNTAX DateAndTime
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"UTC time as reported by this source. If source is not ready
|
|
(no connection to server or no signal), zero-length octet string
|
|
is returned."
|
|
::= { timeSourceEntry 4 }
|
|
|
|
timeZone OBJECT-TYPE
|
|
SYNTAX Integer32 (-1440..1440)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Displacement, in minutes, of local time relative to UTC.
|
|
For example, 240 is UTC+04:00 (Moscow Time),
|
|
-480 is UTC-08:00 (Pacific Standard Time)."
|
|
::= { time 3 }
|
|
|
|
|
|
-- local power sources group
|
|
|
|
powerSourceNumber OBJECT-TYPE
|
|
SYNTAX IntegerNumber
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Number of device's local power sources."
|
|
::= { localPower 1 }
|
|
|
|
powerSourceTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF PowerSourceEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Table of local power sources available to the device, listed in
|
|
priority order."
|
|
::= { localPower 2 }
|
|
|
|
powerSourceEntry OBJECT-TYPE
|
|
SYNTAX PowerSourceEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Power source."
|
|
INDEX { powerSourceId }
|
|
::= { powerSourceTable 1 }
|
|
|
|
PowerSourceEntry ::=
|
|
SEQUENCE {
|
|
powerSourceId
|
|
IntegerIndex,
|
|
powerSourceName
|
|
DisplayString,
|
|
powerSourceNominalVoltage
|
|
Integer32,
|
|
powerSourceStatus
|
|
INTEGER
|
|
}
|
|
|
|
powerSourceId OBJECT-TYPE
|
|
SYNTAX IntegerIndex (1..2147483647)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A unique index of the power source."
|
|
::= { powerSourceEntry 1 }
|
|
|
|
|
|
powerSourceName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Name of the power source. For example: 48V-a."
|
|
::= { powerSourceEntry 2 }
|
|
|
|
powerSourceNominalVoltage OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "V"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Nominal voltage of the power source."
|
|
::= { powerSourceEntry 3 }
|
|
|
|
powerSourceStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
available(1),
|
|
unavailable(2)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Availability status of this power source."
|
|
::= { powerSourceEntry 4 }
|
|
|
|
--- SFP DDM group
|
|
|
|
SfpPowerMilliWatt ::= TEXTUAL-CONVENTION
|
|
DISPLAY-HINT "d-4"
|
|
STATUS current
|
|
DESCRIPTION "SFP optical power from 0 to 6.5535 mW, in 1E-4 mW units."
|
|
SYNTAX Integer32
|
|
|
|
|
|
sfpDDMNumber OBJECT-TYPE
|
|
SYNTAX IntegerNumber
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Number of the sfp modules the device has."
|
|
::= { sfpDDM 1 }
|
|
|
|
sfpDDMTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF SfpDDMEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Table of DDM values read from SFP"
|
|
::= { sfpDDM 2 }
|
|
|
|
sfpDDMEntry OBJECT-TYPE
|
|
SYNTAX SfpDDMEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"SFP Digital diagnostics monitoring"
|
|
INDEX { sfpDDMId }
|
|
::= { sfpDDMTable 1}
|
|
|
|
SfpDDMEntry ::=
|
|
SEQUENCE {
|
|
sfpDDMId
|
|
IntegerIndex,
|
|
sfpDDMTemperature
|
|
IntegerMillis,
|
|
sfpDDMSupplyVoltage
|
|
IntegerMillis,
|
|
sfpDDMTxBiasCurrent
|
|
IntegerWithDecimal,
|
|
sfpDDMTxOutputmW
|
|
SfpPowerMilliWatt,
|
|
sfpDDMTxOutputdBm
|
|
IntegerWithDecimal,
|
|
sfpDDMRxInputmW
|
|
SfpPowerMilliWatt,
|
|
sfpDDMRxInputdBm
|
|
IntegerWithDecimal,
|
|
sfpDDMMediaType
|
|
INTEGER,
|
|
sfpDDMPresence
|
|
INTEGER,
|
|
sfpDDMIfIndex
|
|
InterfaceIndex
|
|
}
|
|
|
|
sfpDDMId OBJECT-TYPE
|
|
SYNTAX IntegerIndex (1..2147483647)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An Index of DDM value"
|
|
::= { sfpDDMEntry 1 }
|
|
|
|
sfpDDMTemperature OBJECT-TYPE
|
|
SYNTAX IntegerMillis(-128000..128000)
|
|
UNITS "C"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Internally measured transceiver temperature in range from -128C to +128C. "
|
|
::= { sfpDDMEntry 2 }
|
|
|
|
sfpDDMSupplyVoltage OBJECT-TYPE
|
|
SYNTAX IntegerMillis(0..65535)
|
|
UNITS "V"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Internally measured transceiver supply voltage in range from 0 to +6.5535 Volts."
|
|
::= { sfpDDMEntry 3 }
|
|
|
|
sfpDDMTxBiasCurrent OBJECT-TYPE
|
|
SYNTAX IntegerWithDecimal(0..1310)
|
|
UNITS "mA"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Measured TX bias current in range from 0 to 131.0 mA"
|
|
::= { sfpDDMEntry 4 }
|
|
|
|
sfpDDMTxOutputmW OBJECT-TYPE
|
|
SYNTAX SfpPowerMilliWatt(0..65535)
|
|
UNITS "mW"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Measured TX output power in range from 0 to 6.5535 mW"
|
|
::= { sfpDDMEntry 5 }
|
|
|
|
sfpDDMTxOutputdBm OBJECT-TYPE
|
|
SYNTAX IntegerWithDecimal(-400..82)
|
|
UNITS "dBm"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Measured TX output power in range from -40 to +8.2 dBm"
|
|
::= { sfpDDMEntry 6 }
|
|
|
|
sfpDDMRxInputmW OBJECT-TYPE
|
|
SYNTAX SfpPowerMilliWatt(0..65535)
|
|
UNITS "mW"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Measured RX received optical power from 0 to 6.5535 mW."
|
|
::= { sfpDDMEntry 7 }
|
|
|
|
sfpDDMRxInputdBm OBJECT-TYPE
|
|
SYNTAX IntegerWithDecimal(-400..82)
|
|
UNITS "dBm"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Measured RX received optical power from -40 to +8.2 dBm."
|
|
::= { sfpDDMEntry 8 }
|
|
|
|
sfpDDMMediaType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
fiber (1),
|
|
copper (2),
|
|
other (3),
|
|
unknown (4)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object returns sfpMedia type.
|
|
when module is not mounted return value is unknown (3)"
|
|
::= { sfpDDMEntry 9 }
|
|
|
|
sfpDDMPresence OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
present (1),
|
|
absent (2)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates if specified SFP interface plugged or not
|
|
present (1) indicates that SFP interface is plugged.
|
|
absent (2) indicates that SFP interface is unplugged."
|
|
::= { sfpDDMEntry 10 }
|
|
|
|
sfpDDMIfIndex OBJECT-TYPE
|
|
SYNTAX InterfaceIndex
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Index of interface in interfaces table, which state this
|
|
SFP interface represents."
|
|
::= { sfpDDMEntry 11 }
|
|
|
|
--- IO group
|
|
|
|
-- io.DIn group
|
|
|
|
ioDInNumber OBJECT-TYPE
|
|
SYNTAX IntegerNumber
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Number of digital inputs the device has"
|
|
::= { ioDIn 1}
|
|
|
|
ioDInTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF IoDInEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Discrete input table represents all discrete (digital) inputs present and
|
|
configured in the device, including voltage inputs, dry contact inputs and
|
|
any other."
|
|
::= { ioDIn 2 }
|
|
|
|
ioDInEntry OBJECT-TYPE
|
|
SYNTAX IoDInEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Discrete (digital) input"
|
|
INDEX { dInId }
|
|
::= { ioDInTable 1 }
|
|
|
|
IoDInEntry ::=
|
|
SEQUENCE {
|
|
dInId
|
|
IntegerIndex,
|
|
dInName
|
|
DisplayString,
|
|
dInState
|
|
INTEGER,
|
|
dInNormalState
|
|
INTEGER,
|
|
dInAlarmSeverity
|
|
INTEGER,
|
|
dInDescription
|
|
DisplayString,
|
|
dInTrapEnable
|
|
INTEGER
|
|
}
|
|
|
|
dInId OBJECT-TYPE
|
|
SYNTAX IntegerIndex (1..2147483647)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A unique index of discrete input. It should remain constant through
|
|
any reconfiguration and reboot of the device."
|
|
::= { ioDInEntry 1 }
|
|
|
|
dInName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Discrete input name, typically - connector marking."
|
|
::= { ioDInEntry 2 }
|
|
|
|
dInState OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
open(1),
|
|
closed(2),
|
|
high(3),
|
|
low(4)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Discrete input state. For voltage input values are high(3) or low(4).
|
|
For npn or dry contact input it is open(1) or closed(2)."
|
|
::= { ioDInEntry 3 }
|
|
|
|
dInNormalState OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
open(1),
|
|
closed(2),
|
|
high(3),
|
|
low(4),
|
|
any(5)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Normal discrete input state. If it is any(5), then input is considered
|
|
informative, else it is has normal (normally open or normally closed) and
|
|
alarm state."
|
|
::= { ioDInEntry 4 }
|
|
|
|
dInAlarmSeverity OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
no(1),
|
|
nonurgent(2),
|
|
urgent(3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"dInAlarmSeverity allows systemAlarm variable to be triggered by the state
|
|
of the input. Setting its to no(1) means that systemAlarm is not triggered;
|
|
setting its to nonurgent(2) or urgent(3) will trigger the systemAlarm if
|
|
dInState is not equal to dInNormalState."
|
|
::= { ioDInEntry 5 }
|
|
|
|
dInDescription OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"User configurable description: input purpose, meaning, net."
|
|
::= { ioDInEntry 6 }
|
|
|
|
dInTrapEnable OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
true(1),
|
|
false(2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"If true(1), trap will be sent on each change of dInState.
|
|
If false(2), no traps will be sent"
|
|
::= { ioDInEntry 7 }
|
|
|
|
-- io.Out group
|
|
|
|
ioDOutNumber OBJECT-TYPE
|
|
SYNTAX IntegerNumber
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Number of digital outputs the device has"
|
|
::= { ioDOut 1}
|
|
|
|
|
|
ioDOutTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF IoDOutEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Discrete output table represents all discrete outputs present and
|
|
configured in the device, including relay outputs, voltage outputs,
|
|
and any other."
|
|
::= { ioDOut 2 }
|
|
|
|
ioDOutEntry OBJECT-TYPE
|
|
SYNTAX IoDOutEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Discrete output"
|
|
INDEX { dOutId }
|
|
::= { ioDOutTable 1 }
|
|
|
|
IoDOutEntry ::=
|
|
SEQUENCE {
|
|
dOutId
|
|
IntegerIndex,
|
|
dOutName
|
|
DisplayString,
|
|
dOutState
|
|
INTEGER,
|
|
dOutNormalState
|
|
INTEGER,
|
|
dOutAlarmSeverity
|
|
INTEGER,
|
|
dOutDescription
|
|
DisplayString,
|
|
dOutTrapEnable
|
|
INTEGER
|
|
}
|
|
|
|
dOutId OBJECT-TYPE
|
|
SYNTAX IntegerIndex (1..2147483647)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A unique index of discrete output. It should remain constant through
|
|
any reconfiguration and reboot of the device."
|
|
::= { ioDOutEntry 1 }
|
|
|
|
dOutName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Discrete output name, typically - connector marking."
|
|
::= { ioDOutEntry 2 }
|
|
|
|
dOutState OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
active(1),
|
|
inactive(2),
|
|
high(3),
|
|
low(4)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Discrete output state. For voltage output values are high(3) or low(4).
|
|
For open-drain, npn, relay coil output (and other) it is active(1) or inactive(2).
|
|
active(1) : coil energized, open-drain or npn output conducting current.
|
|
inactive(2): coil de-energized, open-drain or npn output not conducting."
|
|
::= { ioDOutEntry 3 }
|
|
|
|
dOutNormalState OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
open(1),
|
|
closed(2),
|
|
high(3),
|
|
low(4),
|
|
any(5)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Normal discrete output state. If it is any(5), then input is considered
|
|
informative, else it is has normal (normally open or normally closed) and
|
|
alarm state."
|
|
::= { ioDOutEntry 4 }
|
|
|
|
dOutAlarmSeverity OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
no(1),
|
|
nonurgent(2),
|
|
urgent(3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"dOutAlarmSeverity allows systemAlarm variable to trigger the state
|
|
of the output. Setting its to no(1) means that systemAlarm will not trigger;
|
|
setting its to nonurgent(2) or urgent(3) will trigger the output by changing
|
|
the dOutState to the opposite of dOutNormalState."
|
|
::= { ioDOutEntry 5 }
|
|
|
|
|
|
dOutDescription OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"User configurable description: output purpose, connected load, net."
|
|
::= { ioDOutEntry 6 }
|
|
|
|
dOutTrapEnable OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
true(1),
|
|
false(2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"If true(1), trap will be sent on each change of dOutState.
|
|
If false(2), no traps will be sent"
|
|
::= { ioDOutEntry 7 }
|
|
|
|
--- statReset entity
|
|
|
|
statReset OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
reset(1),
|
|
readValue(2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Writing reset(1) perform a device statistics reset.
|
|
All device statistics should be re-initialized.
|
|
Read always returns readValue(2)."
|
|
::= { stats 11 }
|
|
|
|
--- maintenance.tftp group
|
|
|
|
tftpServerIP OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The IP address of the server from which the file is loaded.
|
|
This value is not stored between device reboots and should
|
|
be set before each TFTP operation."
|
|
::= { tftp 1 }
|
|
|
|
tftpSoftFileName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The remote filename for firmware upgrade.
|
|
This value is not stored between device reboots and should
|
|
be set before each TFTP operation."
|
|
::= { tftp 2 }
|
|
|
|
tftpConfFileName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The remote filename for the up and download the startup-config.
|
|
This value is not stored between device reboots and should
|
|
be set before each TFTP operation."
|
|
::= { tftp 3 }
|
|
|
|
tftpConnectionTimeout OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Time the device will wait for reply from TFTP server,
|
|
during connection and while transferring a block of data.
|
|
While waiting, the device will retransmit it's request
|
|
each 8 seconds (typically). Thus it is reasonable to set
|
|
the timeout to a multiple of 8 seconds.
|
|
If during tftpConnectionTimeout device will not get a responce
|
|
from the server, current TFTP operation will be retried several
|
|
times (set by tftpNumRetries) before ending with and error."
|
|
::= { tftp 4 }
|
|
|
|
tftpNumRetries OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Number of times the device will retry to connect and perform
|
|
requested operation (firmware download, configuration up/download)
|
|
before stopping with error status."
|
|
::= { tftp 5 }
|
|
|
|
|
|
tftpTransCmd OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
noOp (1),
|
|
readValue (2),
|
|
swDownload (3),
|
|
configDownload (4),
|
|
configUpload (5),
|
|
allDownload (6),
|
|
sdSwUpload (9),
|
|
sdSwDownload (10),
|
|
sdConfigUpload (11),
|
|
sdConfigDownload (12),
|
|
sdLoaderUpload (13),
|
|
sdLoaderDownload (14),
|
|
sdCreateSnapshot (15)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object, when read, always returns readValue(2).
|
|
|
|
Setting this object will initiate following actions:
|
|
swDownload(3)
|
|
Download the firmware from TFTP server, filename on the server
|
|
is specified by tftpSoftFileName.
|
|
configDownload(4)
|
|
Download the startup-config from the TFTP server, filename on
|
|
the server is specified by tftpConfFileName.
|
|
configUpLoad(5)
|
|
Download the startup-config to the TFTP-Server, filename on the
|
|
server is specified by tftpConfFileName.
|
|
allDownload(6)
|
|
Download the startup-config and firmware from the TFTP server.
|
|
sdSwUpload(9)
|
|
Upload software from main flash to SD card
|
|
sdSwDownload(10)
|
|
Download software from SD card
|
|
sdConfigUpload(11)
|
|
Upload the startup-config from main flash to SD card
|
|
sdConfigDownload(12)
|
|
Download the startup-config from SD card
|
|
sdLoaderUpload(13)
|
|
Upload bootloader from main flash to SD card
|
|
sdLoaderDownload(14)
|
|
Download bootloader from SD card
|
|
sdCreateSnapshot(15)
|
|
Upload Software, Loader and startup-config to SD card.
|
|
Create filesystem if necesary
|
|
noOp(1)
|
|
Cancel all running SNMP-initiated TFTP operations.
|
|
|
|
TFTP server IP address is configured by tftpServerIP variable.
|
|
|
|
If device does not perform any other maintenance operations, the
|
|
command will be executed, otherwise it will be denied.
|
|
|
|
In case of command execution:
|
|
The value of tftpLastOp will change to the value of the command.
|
|
tftpTransferStatus will reflect transfer progress (connecting-
|
|
transferringData-endedOk/error).
|
|
Current timestamp will be saved into tftpLastOpTime variable.
|
|
During the execution a series of tftpStatusChange is sent.
|
|
|
|
In case of denial:
|
|
tftpLastOp and tftpTransferStatus will not be affected.
|
|
Current timestamp is also not saved into tftpLastOpTime variable.
|
|
By quering tftpLastOpTime before and after setting the tftpTransCmd
|
|
one can find out if the command was denied.
|
|
Current operation that caused the denial can be queried by tftpLastOp.
|
|
tftpStatusChange with tftpTransferStatus value of busyByOther is sent."
|
|
::= { tftp 6 }
|
|
|
|
tftpLastOp OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
noOp (1),
|
|
tftpSwDownload (3),
|
|
tftpConfigDownload (4),
|
|
tftpConfigUpload (5),
|
|
otherSwDownload (6),
|
|
otherConfigDownLoad (7),
|
|
otherConfigUpload (8),
|
|
sdSwUpload (9),
|
|
sdSwDownload (10),
|
|
sdConfigUpload (11),
|
|
sdConfigDownload (12),
|
|
sdLoaderUpload (13),
|
|
sdLoaderDownload (14),
|
|
sdCreateSnapshot (15)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object returns the last executed maintenance operation,
|
|
regardless was it successful or not. It reports following actions:
|
|
noOp(1)
|
|
No maintenance operations were requested since last restart of the device.
|
|
tftpSwDownload(3)
|
|
Software download initiated from SNMP.
|
|
tftpConfigDownload(4)
|
|
Startup-config download initiated from SNMP.
|
|
tftpConfigUpload(5)
|
|
Startup-config upload initiated from SNMP.
|
|
otherSwDownload(6)
|
|
Software download, either TFTP or any other way, not initiated from SNMP.
|
|
otherConfigDownload(7)
|
|
Startup-config download, either TFTP or any other way, not initiated from SNMP.
|
|
otherConfigUpload(8)
|
|
Startup-config upload, either TFTP or any other way, not initiated from SNMP.
|
|
sdSwUpload(9)
|
|
Upload software from main flash to SD card
|
|
sdSwDownload(10)
|
|
Download software from SD card
|
|
sdConfigUpload(11)
|
|
Upload the startup-config from main flash to SD card
|
|
sdConfigDownload(12)
|
|
Download the startup-config from SD card
|
|
sdLoaderUpload(13)
|
|
Upload bootloader from main flash to SD card
|
|
sdLoaderDownload(14)
|
|
Download bootloader from SD card
|
|
sdCreateSnapshot(15)
|
|
Upload Software, Loader and startup-config to SD card.
|
|
Create filesystem if necesary"
|
|
::= { tftp 7 }
|
|
|
|
tftpTransferStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
noOp(1),
|
|
connecting(2),
|
|
transferringData(3),
|
|
endedOk(4),
|
|
error(5),
|
|
busyByOther(6)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Status of SNMP-initiated TFTP transfer. Results:
|
|
noOp(1)
|
|
Default, no TFTP operation was in progress.
|
|
connecting(2)
|
|
Device is connecting to the server specified by tftpServerIP.
|
|
transferringData(3)
|
|
TFTP data transfer is in progress.
|
|
endedOk(4)
|
|
TFTP transfer ended with success.
|
|
error(5)
|
|
TFTP data transfer ended with an Error, (e.g. server timeout or
|
|
remote filename not found). Check TFTP server log file for details.
|
|
busyByOther(6)
|
|
This value can never be read directly from the MIB tree. It is
|
|
used only in tftpStatusChange to notify that device is bysy with
|
|
other maintenance operation and the request for another operation
|
|
was denied.
|
|
|
|
If tftpLastOp is tftpSwDownload(3), tftpConfigDownload(4) or tftpConfigUpload(5),
|
|
this variable shows the status of exactly that operation. Transfers initiated by
|
|
other means (for example CLI command TFTP operation or normal software download),
|
|
do not change this variable. This way one can get full status of SNMP-initiated
|
|
up/download without interference."
|
|
::= { tftp 8 }
|
|
|
|
tftpLastOpTime OBJECT-TYPE
|
|
SYNTAX TimeTicks
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The time in timeticks when last maintenance operation (TFTP software download or
|
|
configuration up/download) was executed from SNMP by setting tftpTransCmd.
|
|
If operation execution was denied, this variable is not affected.
|
|
By comparing tftpLastOpTime before and after tftpTransCmd setting one can
|
|
find out if the command was successful or denied."
|
|
::= { tftp 9 }
|
|
|
|
tftpSoftConfirm OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
softConfirm(1),
|
|
readValue(2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Writing softConfirm(1) to tftpSoftConfirm will confirm previously uploaded firmware.
|
|
Read always returns readValue(2)."
|
|
::= { tftp 10 }
|
|
|
|
tftpProtocolVersion OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
tftp(1),
|
|
ftp(2),
|
|
sftp(3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Allows protocol selection between tftp(1), ftp(2) and sftp(3) for up/download.
|
|
This value is not stored between device reboots and should
|
|
be set before each operation."
|
|
::= { tftp 11 }
|
|
|
|
tftpServerUserName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The Username for Server access.
|
|
This value is not stored between device reboots and should
|
|
be set before each operation."
|
|
::= { tftp 12 }
|
|
|
|
tftpServerUserPass OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The User Password for Server access.
|
|
This value is not stored between device reboots and should
|
|
be set before each operation."
|
|
::= { tftp 13 }
|
|
|
|
tftpServerPortNumber OBJECT-TYPE
|
|
SYNTAX Integer32 (0..65535)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The port number for accessing FTP or SFTP server.
|
|
This value is not stored between device reboots and should
|
|
be set before each operation."
|
|
::= { tftp 14 }
|
|
|
|
macFilterConfigTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF MacFilterConfigEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Table representing MAC-based filter configuration of network interfaces."
|
|
::= { macFilter 1 }
|
|
|
|
macFilterConfigEntry OBJECT-TYPE
|
|
SYNTAX MacFilterConfigEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"MAC-based filter configuration of one interface"
|
|
INDEX { macFilterConfigIfIndex }
|
|
::= { macFilterConfigTable 1 }
|
|
|
|
MacFilterConfigEntry ::=
|
|
SEQUENCE {
|
|
macFilterConfigIfIndex
|
|
IntegerIndex,
|
|
macFilterConfigStatus --- On/Off
|
|
INTEGER,
|
|
macFilterConfigAction --- Filter/Indicate/Block
|
|
INTEGER
|
|
}
|
|
|
|
macFilterConfigIfIndex OBJECT-TYPE
|
|
SYNTAX IntegerIndex(1..2147483647)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Index in interfaces table of the configured interface."
|
|
::= { macFilterConfigEntry 1 }
|
|
|
|
macFilterConfigStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
on(1),
|
|
off(2)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates, whether filtering is on(1) or off(2)."
|
|
::= { macFilterConfigEntry 2 }
|
|
|
|
macFilterConfigAction OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
filter(1),
|
|
indicate(2),
|
|
block(3)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Security action when non-permitted frame is received:
|
|
filter - just drop the frame;
|
|
indicate - drop the frame and send trap;
|
|
block - drop the frame, send trap and permanently block the interface."
|
|
::= { macFilterConfigEntry 3 }
|
|
|
|
|
|
macFilterWhitelistTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF MacFilterWhitelistEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"White list of allowed MAC addresses."
|
|
::= { macFilter 2 }
|
|
|
|
macFilterWhitelistEntry OBJECT-TYPE
|
|
SYNTAX MacFilterWhitelistEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"White list"
|
|
INDEX { macFilterWhitelistIfIndex, macFilterWhitelistIndex }
|
|
::= { macFilterWhitelistTable 1 }
|
|
|
|
MacFilterWhitelistEntry ::=
|
|
SEQUENCE {
|
|
macFilterWhitelistIndex
|
|
IntegerIndex,
|
|
macFilterWhitelistIfIndex
|
|
IntegerIndex,
|
|
macFilterWhitelistMAC
|
|
MacAddress
|
|
}
|
|
|
|
macFilterWhitelistIndex OBJECT-TYPE
|
|
SYNTAX IntegerIndex(1..2147483647)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Index in whitelist table."
|
|
::= { macFilterWhitelistEntry 1 }
|
|
|
|
macFilterWhitelistIfIndex OBJECT-TYPE
|
|
SYNTAX IntegerIndex(1..2147483647)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"IfIndex of the related interface."
|
|
::= { macFilterWhitelistEntry 2 }
|
|
|
|
macFilterWhitelistMAC OBJECT-TYPE
|
|
SYNTAX MacAddress
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Permitted MAC address"
|
|
::= { macFilterWhitelistEntry 3 }
|
|
|
|
|
|
macFilterViolationsTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF MacFilterViolationsEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"List of several last MAC address security violations."
|
|
::= { macFilter 3 }
|
|
|
|
macFilterViolationsEntry OBJECT-TYPE
|
|
SYNTAX MacFilterViolationsEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Violations list"
|
|
INDEX { macFilterViolationsIndex }
|
|
::= { macFilterViolationsTable 1 }
|
|
|
|
MacFilterViolationsEntry ::=
|
|
SEQUENCE {
|
|
macFilterViolationsIndex
|
|
IntegerIndex,
|
|
macFilterViolationsIfIndex
|
|
IntegerIndex,
|
|
macFilterViolationsMAC
|
|
MacAddress,
|
|
macFilterViolationsTimestamp
|
|
TimeTicks
|
|
}
|
|
|
|
macFilterViolationsIndex OBJECT-TYPE
|
|
SYNTAX IntegerIndex(1..2147483647)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Index in violations table."
|
|
::= { macFilterViolationsEntry 1 }
|
|
|
|
macFilterViolationsIfIndex OBJECT-TYPE
|
|
SYNTAX IntegerIndex
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"IfIndex of the related interface."
|
|
::= { macFilterViolationsEntry 2 }
|
|
|
|
macFilterViolationsMAC OBJECT-TYPE
|
|
SYNTAX MacAddress
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Violating MAC address"
|
|
::= { macFilterViolationsEntry 3 }
|
|
|
|
macFilterViolationsTimestamp OBJECT-TYPE
|
|
SYNTAX TimeTicks
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Timestamp of last time an action was taken against security
|
|
violation performed by this MAC address on this interface.
|
|
Measured in 1/100s of second from the last start of the unit -
|
|
same as sysUpTime."
|
|
::= { macFilterViolationsEntry 4 }
|
|
|
|
|
|
|
|
--- Notifications (Traps)
|
|
|
|
|
|
tlmStatusChange NOTIFICATION-TYPE
|
|
OBJECTS { tlmStatus, tlmLastStatusChange }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A tlmStatusChange trap is sent when the
|
|
value of an instance tlmStatus changes. It
|
|
can be utilized by an NMS to trigger polls."
|
|
::= { nateksTraps 1 }
|
|
|
|
|
|
alarmValueChange NOTIFICATION-TYPE
|
|
OBJECTS { alarmId, alarmIfIndex, alarmName, alarmValue, alarmDisplayType, alarmCutoff, ifDescr }
|
|
STATUS current
|
|
|
|
--&FILTNAME "MAJOR ALARM ON"
|
|
--&ACTIONS {log, critical}
|
|
--&CLEARS {"ALARM OFF", "ALARM CUTOFF"}
|
|
--&MATCH {alarmIfIndex, alarmName, alarmValue "on", alarmCutoff "off", alarmDisplayType "major"}
|
|
--&MESG "$7 alarm $3 ON"
|
|
|
|
--&FILTNAME "MINOR ALARM ON"
|
|
--&ACTIONS {log, major}
|
|
--&CLEARS {"ALARM OFF", "ALARM CUTOFF"}
|
|
--&MATCH {alarmIfIndex, alarmName, alarmValue "on", alarmCutoff "off", alarmDisplayType "minor"}
|
|
--&MESG "$7 alarm $3 ON"
|
|
|
|
--&FILTNAME "MAINTENANCE ALARM ON"
|
|
--&ACTIONS {log, minor}
|
|
--&CLEARS {"ALARM OFF", "ALARM CUTOFF"}
|
|
--&MATCH {alarmIfIndex, alarmName, alarmValue "on", alarmCutoff "off", alarmDisplayType "maintenance"}
|
|
--&MESG "$7 alarm $3 ON"
|
|
|
|
--&FILTNAME "ALARM OFF"
|
|
--&ACTIONS {log, normal}
|
|
--&CLEARS {"MAJOR ALARM ON", "MINOR ALARM ON", "MAINTENANCE ALARM ON", "ALARM CUTOFF"}
|
|
--&MATCH {alarmIfIndex, alarmName, alarmValue "off", alarmCutoff "off"}
|
|
--&MESG "$7 alarm $3 OFF"
|
|
|
|
--&FILTNAME "ALARM CUTOFF"
|
|
--&ACTIONS {log, normal}
|
|
--&CLEARS {"MAJOR ALARM ON", "MINOR ALARM ON", "MAINTENANCE ALARM ON", "ALARM OFF"}
|
|
--&MATCH {alarmIfIndex, alarmName, alarmCutoff "on"}
|
|
--&MESG "$7 alarm $3 OFF"
|
|
|
|
DESCRIPTION
|
|
"A alarmValueChange trap is sent when alarm value changes.
|
|
It can be utilized by an NMS to trigger polls."
|
|
::= { nateksTraps 2 }
|
|
|
|
|
|
tftpStatusChange NOTIFICATION-TYPE
|
|
OBJECTS { tftpLastOp, tftpTransferStatus, tftpLastOpTime }
|
|
STATUS current
|
|
|
|
--&FILTNAME "TFTP denied"
|
|
--&ACTIONS {log, minor}
|
|
--&MATCH {tftpTransferStatus "busyByOther"}
|
|
--&MESG "TFTP transfer was denied because operation $'1 is still in progress"
|
|
|
|
--&FILTNAME "TFTP connecting"
|
|
--&ACTIONS {log, warning}
|
|
--&MATCH {tftpLastOp, tftpLastOpTime, tftpTransferStatus "connecting"}
|
|
--&MESG "TFTP operation $'1 status: connecting..."
|
|
|
|
--&FILTNAME "TFTP transfer"
|
|
--&ACTIONS {log, warning}
|
|
--&CLEARS {"TFTP connecting"}
|
|
--&MATCH {tftpLastOp, tftpLastOpTime, tftpTransferStatus "transferringData"}
|
|
--&MESG "TFTP operation $'1 status: transferring..."
|
|
|
|
--&FILTNAME "TFTP ended OK"
|
|
--&ACTIONS {log, normal}
|
|
--&CLEARS {"TFTP connecting", "TFTP transfer"}
|
|
--&MATCH {tftpLastOp, tftpLastOpTime, tftpTransferStatus "endedOk"}
|
|
--&MESG "TFTP operation $'1 status: OK"
|
|
|
|
--&FILTNAME "TFTP error"
|
|
--&ACTIONS {log, minor}
|
|
--&CLEARS {"TFTP connecting", "TFTP transfer"}
|
|
--&MATCH {tftpLastOp, tftpLastOpTime, tftpTransferStatus "error"}
|
|
--&MESG "TFTP operation $'1 status: error"
|
|
|
|
DESCRIPTION
|
|
"This trap is sent during the process of SNMP-initiated TFTP maintenance
|
|
command (TFTP software download or configuration up/download) to report
|
|
current execution status. In this case tftpLastOp shows the current
|
|
operation, tftpLastOpTime indicates starting time of current operation,
|
|
tftpTransferStatus indicates status of the transfer.
|
|
|
|
If the command is denied, this trap is also sent with tftpTransferStatus
|
|
value of busyByOther. In this case tftpLastOp indicates the operation that
|
|
conflicted with the command."
|
|
::= { nateksTraps 3 }
|
|
|
|
|
|
macFilterViolation NOTIFICATION-TYPE
|
|
OBJECTS { macFilterViolationsIfIndex, ifDescr, macFilterViolationsMAC, macFilterConfigAction }
|
|
STATUS current
|
|
|
|
--&FILTNAME "MAC violation: filtered"
|
|
--&ACTIONS {log, warning}
|
|
--&MATCH { macFilterConfigAction "indicate"}
|
|
--&MESG "$2 access violation, MAC $3"
|
|
|
|
--&FILTNAME "MAC violation: blocked"
|
|
--&ACTIONS {log, major}
|
|
--&MATCH { macFilterConfigAction "block"}
|
|
--&MESG "$2 blocked due to access violation by MAC $3"
|
|
|
|
DESCRIPTION
|
|
"This trap is sent to indicate that MAC filter access violation
|
|
has happened and specific security action will be performed.
|
|
Variables:
|
|
macFilterViolationsIfIndex, ifDescr - index and name of interface;
|
|
macFilterViolationsMAC - violating MAC;
|
|
macFilterConfigAction - action to be performed.
|
|
"
|
|
::= { nateksTraps 4 }
|
|
|
|
|
|
dInStateChange NOTIFICATION-TYPE
|
|
OBJECTS { dInName, dInState, dInNormalState, dInDescription }
|
|
STATUS current
|
|
|
|
--&FILTNAME "Normally-open Closed"
|
|
--&ACTIONS {log, warning}
|
|
--&MATCH { dInNormalState "open", dInState "closed" }
|
|
--&MESG "Input: $1 with description: $4 Closed"
|
|
|
|
--&FILTNAME "Normally-closed Open"
|
|
--&ACTIONS {log, warning}
|
|
--&MATCH { dInNormalState "closed", dInState "open" }
|
|
--&MESG "Input: $1 with description: $4 Opened"
|
|
|
|
--&FILTNAME "Normally-open Open"
|
|
--&ACTIONS {log, normal}
|
|
--&CLEARS {"Normally-open Closed"}
|
|
--&MATCH { dInNormalState "open", dInState "open" }
|
|
--&MESG "Input: $1 with description: $4 Opened"
|
|
|
|
--&FILTNAME "Normally-closed Closed"
|
|
--&CLEARS {"Input trigger: Normally-closed Open"}
|
|
--&ACTIONS {log, normal}
|
|
--&MATCH { dInNormalState "closed", dInState "closed" }
|
|
--&MESG "Input: $1 with description: $4 Closed"
|
|
|
|
|
|
DESCRIPTION
|
|
"This trap is sent to indicate that input state has changed."
|
|
::= { nateksTraps 5 }
|
|
|
|
dOutStateChange NOTIFICATION-TYPE
|
|
OBJECTS { dOutName, dOutState, dOutNormalState, dOutDescription }
|
|
STATUS current
|
|
|
|
--&FILTNAME "Output Active"
|
|
--&ACTIONS {log, warning}
|
|
--&MATCH { dOutName, dOutState "active", dOutDescription }
|
|
--&MESG "Output $1 with description: $4 Active"
|
|
|
|
--&FILTNAME "Output Inactive"
|
|
--&ACTIONS {log, warning}
|
|
--&MATCH { dOutName, dOutState "inactive", dOutDescription }
|
|
--&MESG "Output $1 with description: $4 Inactive"
|
|
|
|
DESCRIPTION
|
|
"This trap is sent to indicate that output state has changed."
|
|
::= { nateksTraps 6 }
|
|
|
|
|
|
nateksMinimalGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
systemAlarm,
|
|
systemReset
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A minimal collection of objects requred from any supporting device."
|
|
::= { nateksMIBGroup 1 }
|
|
|
|
nateksCommonInfoGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
model,
|
|
softwareVersion
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Basic unit information regarding model and software of a unit."
|
|
::= { nateksMIBGroup 2 }
|
|
|
|
nateksCommonExtGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
model,
|
|
id,
|
|
hardwareVersion,
|
|
softwareVersion,
|
|
softwareDate,
|
|
moduleType,
|
|
subrackAddress,
|
|
errorCode,
|
|
serialNumber
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Extended unit information regarding hardware and software of a unit."
|
|
::= { nateksMIBGroup 3 }
|
|
|
|
nateksConfigBasicGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
configDefault,
|
|
configNumberValues,
|
|
valueName,
|
|
valueRunning
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Basic configuration management interface."
|
|
::= { nateksMIBGroup 4 }
|
|
|
|
nateksConfigConfirmedGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
configDefault,
|
|
configNumberValues,
|
|
valueName,
|
|
valueType,
|
|
valueStatus,
|
|
valueStartup,
|
|
valueRunning,
|
|
valueNew,
|
|
configApplyAll,
|
|
configConfirm
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Minimal configuration management interface with support
|
|
for Apply-Confirm configuration behaviour."
|
|
::= { nateksMIBGroup 5 }
|
|
|
|
nateksConfigBackupGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
valueBackup,
|
|
configBackup,
|
|
configRestore
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Local configuration backup management interface."
|
|
::= { nateksMIBGroup 6 }
|
|
|
|
|
|
nateksConfigGroupsGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
valueGroup,
|
|
valueGroupName,
|
|
configNumberGroups,
|
|
groupName,
|
|
groupType,
|
|
groupStatus
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Management interface for variable groups."
|
|
::= { nateksMIBGroup 7 }
|
|
|
|
|
|
nateksConfigRWGroup OBJECT-GROUP
|
|
OBJECTS { configRW }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Management interface for full configuration profile read/write."
|
|
::= { nateksMIBGroup 8 }
|
|
|
|
|
|
nateksG826Group OBJECT-GROUP
|
|
OBJECTS {
|
|
g826Number,
|
|
g826Reset,
|
|
g826IfIndex,
|
|
g826Name,
|
|
g826EB,
|
|
g826ES,
|
|
g826SES,
|
|
g826BBE,
|
|
g826AvailableTime,
|
|
g826UnavailableTime,
|
|
g826StatReset
|
|
}
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"Use of g826Table is deprecated in favor of ifG826Table."
|
|
::= { nateksMIBGroup 9 }
|
|
|
|
nateksIfG826Group OBJECT-GROUP
|
|
OBJECTS {
|
|
g826Number,
|
|
g826Reset,
|
|
ifG826Name,
|
|
ifG826EB,
|
|
ifG826ES,
|
|
ifG826SES,
|
|
ifG826BBE,
|
|
ifG826AvailableTime,
|
|
ifG826UnavailableTime,
|
|
ifG826StatReset
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"G.826 statistics information and management."
|
|
::= { nateksMIBGroup 10 }
|
|
|
|
|
|
nateksAlarmGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
alarmNumber,
|
|
alarmTrapEnable,
|
|
alarmId,
|
|
alarmIfIndex,
|
|
alarmName,
|
|
alarmValue,
|
|
alarmCutoff,
|
|
alarmType,
|
|
alarmDisplayType
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Old style alarm table. Using ifAlarmTable is more convenient than alarmTable.
|
|
Members of this group are included into alarmValueChange notification."
|
|
::= { nateksMIBGroup 11 }
|
|
|
|
nateksIfAlarmGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
alarmNumber,
|
|
alarmTrapEnable,
|
|
ifAlarmId,
|
|
ifAlarmIfIndex,
|
|
ifAlarmName,
|
|
ifAlarmValue,
|
|
ifAlarmCutoff,
|
|
ifAlarmType,
|
|
ifAlarmDisplayType
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Alarm information and management."
|
|
::= { nateksMIBGroup 12 }
|
|
|
|
nateksTlmGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
tlmNumber,
|
|
tlmClear,
|
|
tlmName,
|
|
tlmStatus,
|
|
tlmLastStatusChange,
|
|
tlmSetup,
|
|
tlmTrapEnable
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"TLM information and management."
|
|
::= { nateksMIBGroup 13 }
|
|
|
|
nateksDSLGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
dslChannelNumber,
|
|
dslUnitType,
|
|
dslChannelIfIndex,
|
|
dslChannelMode,
|
|
dslChannelStandard,
|
|
dslChannelClockReference,
|
|
dslChannelLineCodeConfig,
|
|
dslChannelPSDConfig,
|
|
dslChannelBaserateConfig,
|
|
dslChannelLineCode,
|
|
dslChannelPSD,
|
|
dslChannelBaserate,
|
|
dslChannelLineRate,
|
|
dslChannelPayloadRate,
|
|
dslChannelStatus,
|
|
dslChannelNMR,
|
|
dslChannelPowerBackoff,
|
|
dslChannelFarEndPowerBackoff,
|
|
dslChannelLoopAttenuation,
|
|
dslChannelEOCNumber
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"DSL channel information."
|
|
::= { nateksMIBGroup 14 }
|
|
|
|
nateksDSLMultipairGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
dslGroupNumber,
|
|
dslGroupType,
|
|
dslGroupMainChannel,
|
|
dslGroupChannel1,
|
|
dslGroupChannel2,
|
|
dslGroupChannel3,
|
|
dslGroupChannel4
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"DSL multi-pair bonding information."
|
|
::= { nateksMIBGroup 15 }
|
|
|
|
nateksDSLLTUGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
dslChannelRegeneratorNumber,
|
|
dslChannelRemotePower,
|
|
dslChannelRemotePowerVoltage
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Information aout remote power and regenerators present only on LTU/NTU DSL units."
|
|
::= { nateksMIBGroup 16 }
|
|
|
|
nateksDSLRegenerationGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
dslRegenerationChannels,
|
|
dslRegenerationSide1,
|
|
dslRegenerationSide2
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"DSL regeneration channels information."
|
|
::= { nateksMIBGroup 17 }
|
|
|
|
nateksIndicationGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
indicationLedNumber,
|
|
indicationLedDescription,
|
|
indicationLedState,
|
|
indicationLedFlash
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"LED indication status."
|
|
::= { nateksMIBGroup 18 }
|
|
|
|
|
|
nateksTemperatureGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
temperatureSensorNumber,
|
|
temperatureSensorDescription,
|
|
temperatureSensorValue
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Temperature sensors data."
|
|
::= { nateksMIBGroup 19 }
|
|
|
|
nateksTimeGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
timeSourceNumber,
|
|
timeSourceName,
|
|
timeSourceStratum,
|
|
timeSourceValue,
|
|
timeZone
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Data from time reference sources."
|
|
::= { nateksMIBGroup 20 }
|
|
|
|
|
|
nateksLocalPowerGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
powerSourceNumber,
|
|
powerSourceName,
|
|
powerSourceNominalVoltage,
|
|
powerSourceStatus
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Local power sources status."
|
|
::= { nateksMIBGroup 21 }
|
|
|
|
|
|
nateksTFTPManagementGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
tftpServerIP,
|
|
tftpSoftFileName,
|
|
tftpConfFileName,
|
|
tftpConnectionTimeout,
|
|
tftpNumRetries,
|
|
tftpTransCmd,
|
|
tftpLastOp,
|
|
tftpTransferStatus,
|
|
tftpLastOpTime,
|
|
tftpSoftConfirm,
|
|
tftpProtocolVersion,
|
|
tftpServerUserName,
|
|
tftpServerUserPass,
|
|
tftpServerPortNumber
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Software upload and configuration upload/download via TFTP protocol."
|
|
::= { nateksMIBGroup 22 }
|
|
|
|
|
|
nateksMacFilterGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
macFilterConfigStatus,
|
|
macFilterConfigAction,
|
|
macFilterWhitelistMAC,
|
|
macFilterViolationsIfIndex,
|
|
macFilterViolationsMAC,
|
|
macFilterViolationsTimestamp
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"MAC-based Ethernet port access control group."
|
|
::= { nateksMIBGroup 23 }
|
|
|
|
nateksSfpDDMGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
sfpDDMNumber,
|
|
sfpDDMTemperature,
|
|
sfpDDMSupplyVoltage,
|
|
sfpDDMTxBiasCurrent,
|
|
sfpDDMTxOutputmW,
|
|
sfpDDMTxOutputdBm,
|
|
sfpDDMRxInputmW,
|
|
sfpDDMRxInputdBm,
|
|
sfpDDMMediaType,
|
|
sfpDDMPresence,
|
|
sfpDDMIfIndex
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"SFP DDM parameters group"
|
|
::= { nateksMIBGroup 24 }
|
|
|
|
nateksDigitalIoGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
ioDInNumber,
|
|
dInName,
|
|
dInState,
|
|
dInNormalState,
|
|
dInAlarmSeverity,
|
|
dInDescription,
|
|
dInTrapEnable,
|
|
ioDOutNumber,
|
|
dOutName,
|
|
dOutState,
|
|
dOutNormalState,
|
|
dOutAlarmSeverity,
|
|
dOutDescription,
|
|
dOutTrapEnable
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Digital Input/Output managementgroup"
|
|
::= { nateksMIBGroup 25 }
|
|
|
|
nateksStatResetGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
statReset
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Statistics reset group"
|
|
::= { nateksMIBGroup 26 }
|
|
|
|
nateksTlmNotificationGroup NOTIFICATION-GROUP
|
|
NOTIFICATIONS { tlmStatusChange }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"TLM status change notification is required if an agent implements TLM table."
|
|
::= { nateksMIBGroup 1001 }
|
|
|
|
nateksAlarmNotificationGroup NOTIFICATION-GROUP
|
|
NOTIFICATIONS { alarmValueChange }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Alarm value change notification is required if an agent implements Alarm table."
|
|
::= { nateksMIBGroup 1002 }
|
|
|
|
nateksTFTPNotificationGroup NOTIFICATION-GROUP
|
|
NOTIFICATIONS { tftpStatusChange }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"TFTP software or configuration management requires implementation of this
|
|
notification to communicate the status of operation to the management station."
|
|
::= { nateksMIBGroup 1003 }
|
|
|
|
nateksMacFilterNotificationGroup NOTIFICATION-GROUP
|
|
NOTIFICATIONS { macFilterViolation }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Notification about security violations are required if an agent implements MAC filtering."
|
|
::= { nateksMIBGroup 1004 }
|
|
|
|
nateksDigitalIoNotificationGroup NOTIFICATION-GROUP
|
|
NOTIFICATIONS { dInStateChange, dOutStateChange }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Notification about input/output state changes are required if an agent implements digital IO."
|
|
::= { nateksMIBGroup 1005 }
|
|
|
|
|
|
nateksMinCompliance MODULE-COMPLIANCE
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Minimal variable set to claim compiance with NATEKS-MIB."
|
|
MODULE
|
|
MANDATORY-GROUPS { nateksMinimalGroup,
|
|
nateksCommonInfoGroup
|
|
}
|
|
OBJECT systemReset
|
|
MIN-ACCESS read-only
|
|
DESCRIPTION
|
|
"System reset action may be unavailable due to security restrictions."
|
|
::= { nateksMIBCompliance 1 }
|
|
|
|
nateksBasicCompliance MODULE-COMPLIANCE
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Basic variable set to claim compiance with NATEKS-MIB."
|
|
MODULE
|
|
MANDATORY-GROUPS { nateksMinimalGroup,
|
|
nateksCommonExtGroup
|
|
}
|
|
OBJECT systemReset
|
|
MIN-ACCESS read-only
|
|
DESCRIPTION
|
|
"System reset action may be unavailable due to security restrictions."
|
|
OBJECT serialNumber
|
|
MIN-ACCESS not-accessible
|
|
DESCRIPTION
|
|
"serialNumber variable is required by all new agent implementations
|
|
but not necessary for legacy agents and for those, where this information
|
|
is not available to the agent."
|
|
::= { nateksMIBCompliance 2 }
|
|
|
|
nateksConfigBasicCompliance MODULE-COMPLIANCE
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Basic capabilities of configuration management."
|
|
MODULE
|
|
MANDATORY-GROUPS { nateksConfigBasicGroup }
|
|
::= { nateksMIBCompliance 3 }
|
|
|
|
nateksConfigConfirmedCompliance MODULE-COMPLIANCE
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Capabilities of configuration management with Apply and Confirm behaviour."
|
|
MODULE
|
|
MANDATORY-GROUPS { nateksConfigConfirmedGroup }
|
|
::= { nateksMIBCompliance 4 }
|
|
|
|
nateksConfigBackupCompliance MODULE-COMPLIANCE
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Capabilities of local configuration backup management."
|
|
MODULE
|
|
MANDATORY-GROUPS { nateksConfigBackupGroup }
|
|
::= { nateksMIBCompliance 5 }
|
|
|
|
nateksConfigFullCompliance MODULE-COMPLIANCE
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Basic capabilities of configuration management."
|
|
MODULE
|
|
MANDATORY-GROUPS { nateksConfigConfirmedGroup,
|
|
nateksConfigBackupGroup,
|
|
nateksConfigGroupsGroup
|
|
}
|
|
GROUP nateksConfigRWGroup
|
|
DESCRIPTION
|
|
"The configRW variable may be not accessible if implementation of
|
|
configuration management subsystem of a device can not serialize
|
|
configuration to a string of bytes.
|
|
The configRW variable may be read-only if writing device configuration
|
|
this way can not be supported.
|
|
The configRW variable may be not accessible if device configuration
|
|
size exceeds internal SNMP PDU size limitations of device's SNMP agent."
|
|
::= { nateksMIBCompliance 6 }
|
|
|
|
nateksG826Compliance MODULE-COMPLIANCE
|
|
STATUS current
|
|
DESCRIPTION
|
|
"G.826 statistics representation and management"
|
|
MODULE
|
|
MANDATORY-GROUPS { nateksIfG826Group }
|
|
|
|
OBJECT ifG826EB
|
|
MIN-ACCESS not-accessible
|
|
DESCRIPTION
|
|
"For interfaces, where errors are not reported per block of data received
|
|
(like transparent E1), errored blocks counters should be unavailable."
|
|
|
|
OBJECT ifG826ES
|
|
MIN-ACCESS not-accessible
|
|
DESCRIPTION
|
|
"For interfaces, where errors are not reported per block of data received
|
|
(like transparent E1),errored seconds counters should be unavailable."
|
|
|
|
OBJECT ifG826SES
|
|
MIN-ACCESS not-accessible
|
|
DESCRIPTION
|
|
"For interfaces, where errors are not reported per block of data received
|
|
(like transparent E1), severely errored seconds counters should be unavailable."
|
|
|
|
OBJECT ifG826BBE
|
|
MIN-ACCESS not-accessible
|
|
DESCRIPTION
|
|
"For interfaces, where errors are not reported per block of data received
|
|
(like transparent E1), background block errors counters should be unavailable."
|
|
::= { nateksMIBCompliance 7 }
|
|
|
|
|
|
nateksIfAlarmCompliance MODULE-COMPLIANCE
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Alarm representation and management"
|
|
MODULE
|
|
MANDATORY-GROUPS { nateksIfAlarmGroup, nateksAlarmNotificationGroup }
|
|
GROUP nateksAlarmGroup
|
|
DESCRIPTION
|
|
"Implementation for alarmTable is not absolutely required, but members of
|
|
it should be included into alarmValueChange notification."
|
|
OBJECT alarmId
|
|
MIN-ACCESS accessible-for-notify
|
|
DESCRIPTION
|
|
"In SMIv1 version of MIB alarmId was accessible as read-only. Implementations
|
|
can now not implement this variable in table and use it only in notifications."
|
|
OBJECT ifAlarmId
|
|
MIN-ACCESS accessible-for-notify
|
|
DESCRIPTION
|
|
"In SMIv1 version of MIB alarmId was accessible as read-only. Implementations
|
|
can now not implement this variable in table and use it only in notifications."
|
|
OBJECT ifAlarmIfIndex
|
|
MIN-ACCESS not-accessible
|
|
DESCRIPTION
|
|
"In SMIv1 version of MIB alarmId was accessible as read-only. Implementations
|
|
can now not implement this variable"
|
|
OBJECT alarmTrapEnable
|
|
MIN-ACCESS read-only
|
|
DESCRIPTION
|
|
"If device can not send alarm traps, alarmTrapEnable may be read-only and
|
|
indicate 'false'."
|
|
::= { nateksMIBCompliance 8 }
|
|
|
|
nateksTLMCompliance MODULE-COMPLIANCE
|
|
STATUS current
|
|
DESCRIPTION
|
|
"TLM (dry contact inputs) representation and management"
|
|
MODULE
|
|
MANDATORY-GROUPS { nateksTlmGroup, nateksTlmNotificationGroup }
|
|
::= { nateksMIBCompliance 9 }
|
|
|
|
nateksDSLLTUCompliance MODULE-COMPLIANCE
|
|
STATUS current
|
|
DESCRIPTION
|
|
"DSL information for LTU and NTU DSL units"
|
|
MODULE
|
|
MANDATORY-GROUPS { nateksDSLGroup,
|
|
nateksDSLMultipairGroup,
|
|
nateksDSLLTUGroup
|
|
}
|
|
::= { nateksMIBCompliance 10 }
|
|
|
|
nateksDSLRegeneratorCompliance MODULE-COMPLIANCE
|
|
STATUS current
|
|
DESCRIPTION
|
|
"DSL information for DSL regenerator/repeater units"
|
|
MODULE
|
|
MANDATORY-GROUPS { nateksDSLGroup,
|
|
nateksDSLMultipairGroup,
|
|
nateksDSLRegenerationGroup
|
|
}
|
|
::= { nateksMIBCompliance 11 }
|
|
|
|
nateksIndicationCompliance MODULE-COMPLIANCE
|
|
STATUS current
|
|
DESCRIPTION
|
|
"LED status information."
|
|
MODULE
|
|
MANDATORY-GROUPS { nateksIndicationGroup }
|
|
::= { nateksMIBCompliance 12 }
|
|
|
|
nateksTemperatureCompliance MODULE-COMPLIANCE
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Temperature sensors data."
|
|
MODULE
|
|
MANDATORY-GROUPS { nateksTemperatureGroup }
|
|
::= { nateksMIBCompliance 13 }
|
|
|
|
nateksTimeCompliance MODULE-COMPLIANCE
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Data from time reference sources."
|
|
MODULE
|
|
MANDATORY-GROUPS { nateksTimeGroup }
|
|
::= { nateksMIBCompliance 14 }
|
|
|
|
nateksLocalPowerCompliance MODULE-COMPLIANCE
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Local power sources status."
|
|
MODULE
|
|
MANDATORY-GROUPS { nateksLocalPowerGroup }
|
|
::= { nateksMIBCompliance 15 }
|
|
|
|
nateksTFTPManagementCompliance MODULE-COMPLIANCE
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Software upload and configuration upload/download via TFTP protocol."
|
|
MODULE
|
|
MANDATORY-GROUPS { nateksTFTPManagementGroup, nateksTFTPNotificationGroup }
|
|
::= { nateksMIBCompliance 16 }
|
|
|
|
nateksMacFilterCompliance MODULE-COMPLIANCE
|
|
STATUS current
|
|
DESCRIPTION
|
|
"MAC-based Ethernet port access control group."
|
|
MODULE
|
|
MANDATORY-GROUPS { nateksMacFilterGroup, nateksMacFilterNotificationGroup }
|
|
::= { nateksMIBCompliance 17 }
|
|
|
|
nateksSfpDDMGroupCompliance MODULE-COMPLIANCE
|
|
STATUS current
|
|
DESCRIPTION
|
|
"SFP DDM information support."
|
|
MODULE
|
|
MANDATORY-GROUPS { nateksSfpDDMGroup }
|
|
::= { nateksMIBCompliance 18 }
|
|
|
|
nateksDigitalIoCompliance MODULE-COMPLIANCE
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Digital input/output management support."
|
|
MODULE
|
|
MANDATORY-GROUPS { nateksDigitalIoGroup, nateksDigitalIoNotificationGroup }
|
|
::= { nateksMIBCompliance 19 }
|
|
|
|
nateksStatResetCompliance MODULE-COMPLIANCE
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Statistics reset support."
|
|
MODULE
|
|
MANDATORY-GROUPS { nateksStatResetGroup }
|
|
|
|
::= {nateksMIBCompliance 20 }
|
|
|
|
|
|
END
|