MBG-SNMP-NTP-DISPLAY-MIB DEFINITIONS ::= BEGIN
IMPORTS
OBJECT-TYPE FROM RFC-1212
TRAP-TYPE FROM RFC-1215
DisplayString FROM RFC1213-MIB
mbgSnmpRoot FROM MBG-SNMP-ROOT-MIB;
mbgNtpDisp OBJECT IDENTIFIER ::= { mbgSnmpRoot 20 }
--LAST-UPDATED "201211080621Z"
--ORGANIZATION "www.meinberg.de"
--CONTACT-INFO
-- "postal: Meinberg Funkuhren
-- Auf der Landwehr 22
-- 31812 Bad Pyrmont
-- Germany
-- email: info@meinberg.de"
--DESCRIPTION
--"Initial revision"
--REVISION "201211080621Z"
--DESCRIPTION
-- "Covering NTP display from Meinberg"
mbgNtpDispInfo OBJECT IDENTIFIER ::= {mbgNtpDisp 2}
mbgNtpDispTraps OBJECT IDENTIFIER ::= {mbgNtpDisp 3}
-- Display info
mbgNtpDispClockType OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Type of clock"
::= { mbgNtpDispInfo 1 }
mbgNtpDispClockTypeVal OBJECT-TYPE
SYNTAX Integer32
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Type of clock as integer"
::= { mbgNtpDispInfo 2 }
mbgNtpDispMode OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Display mode"
::= { mbgNtpDispInfo 3 }
mbgNtpDispModeVal OBJECT-TYPE
SYNTAX Integer32
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Display mode as integer"
::= { mbgNtpDispInfo 4 }
mbgNtpDispState OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Display's state"
::= { mbgNtpDispInfo 5 }
-- Traps
mbgNtpDispTrapBoot TRAP-TYPE
ENTERPRISE mbgNtpDispTraps
DESCRIPTION
"Trap to be sent when display reboots"
::= 1
mbgNtpDispTrapSync TRAP-TYPE
ENTERPRISE mbgNtpDispTraps
DESCRIPTION
"Trap to be sent when display is synchronized"
::= 2
mbgNtpDispTrapNotSync TRAP-TYPE
ENTERPRISE mbgNtpDispTraps
DESCRIPTION
"Trap to be sent when display is not synchronized"
::= 3
mbgNtpDispTrapTestNotification TRAP-TYPE
ENTERPRISE mbgNtpDispTraps
DESCRIPTION
"Testing notification"
::= 4
END