-- **SDOC***********************************************************************
|
||
-- *****************************************************************************
|
||
--
|
||
-- Copyright(c) 2004-2005 Mediatrix Telecom, Inc.
|
||
-- Copyright(c) 2008 Media5 Corporation. ("Media5")
|
||
--
|
||
-- NOTICE:
|
||
-- This document contains information that is confidential and proprietary
|
||
-- to Media5.
|
||
--
|
||
-- Media5 reserves all rights to this document as well as to the Intellectual
|
||
-- Property of the document and the technology and know-how that it includes
|
||
-- and represents.
|
||
--
|
||
-- This publication cannot be reproduced, neither in whole nor in part, in
|
||
-- any form whatsoever without written prior approval by Media5.
|
||
--
|
||
-- Media5 reserves the right to revise this publication and make changes at
|
||
-- any time and without the obligation to notify any person and/or entity of
|
||
-- such revisions and/or changes.
|
||
--
|
||
-- *****************************************************************************
|
||
-- *****************************************************************************
|
||
--
|
||
-- Configuration of signaling and telephony attributes of a H.323 unit. Applies
|
||
-- to H.323 terminals and H.323 gateways.
|
||
--
|
||
-- A H.323 terminal is a unit with only FXS ports. A H.323 gateway is a unit
|
||
-- with only FXO ports.
|
||
--
|
||
-- *****************************************************************************
|
||
-- **EDOC***********************************************************************
|
||
|
||
MX-H323-ATTRIBUTES-MIB
|
||
DEFINITIONS ::= BEGIN
|
||
|
||
IMPORTS
|
||
OBJECT-TYPE,
|
||
MODULE-IDENTITY,
|
||
OBJECT-IDENTITY,
|
||
Unsigned32
|
||
FROM SNMPv2-SMI
|
||
OBJECT-GROUP,
|
||
NOTIFICATION-GROUP,
|
||
MODULE-COMPLIANCE
|
||
FROM SNMPv2-CONF
|
||
MxEnableState,
|
||
MxIpAddress,
|
||
MxIpPort,
|
||
MxIpDhcpSiteSpecificCode
|
||
FROM MX-TC
|
||
ifIndex
|
||
FROM RFC1213-MIB
|
||
h323,
|
||
ipAddressStatusH323,
|
||
ipAddressConfigH323Static,
|
||
ipAddressConfigH323Dhcp
|
||
FROM MX-H323-MIB;
|
||
|
||
h323AttributesMIB MODULE-IDENTITY
|
||
LAST-UPDATED "200803050000Z"
|
||
ORGANIZATION "Mediatrix Telecom, Inc."
|
||
CONTACT-INFO "Mediatrix Telecom, Inc.
|
||
4229, Garlock Street
|
||
Sherbrooke (Quebec)
|
||
Canada
|
||
Phone: (819) 829-8749
|
||
"
|
||
DESCRIPTION "This MIB contains H.323 configuration objects."
|
||
|
||
-- *************************************************************************
|
||
-- Revision history
|
||
-- *************************************************************************
|
||
REVISION "200808250000Z"
|
||
DESCRIPTION "Correction of h323AttributesCalledPartyNumberTypeOfNumber enum syntax"
|
||
|
||
REVISION "200803050000Z"
|
||
DESCRIPTION "Addition of privateNumber in h323AttributesCalledPartyNumberTypeOfNumber."
|
||
|
||
REVISION "200501180000Z"
|
||
DESCRIPTION "Addition of h323AttributesVoiceCapabilitySendingMethod."
|
||
|
||
REVISION "200410150000Z"
|
||
DESCRIPTION "Addition of h323AttributesParallelH245Enable."
|
||
|
||
REVISION "200407140000Z"
|
||
DESCRIPTION "Addition of Unsigned32 in IMPORTS list."
|
||
|
||
REVISION "200401210000Z"
|
||
DESCRIPTION "Addition of h323AttributesQ931CalledPartyNumberTable."
|
||
|
||
REVISION "200311050000Z"
|
||
DESCRIPTION "Addition of h323AttributesQ931,
|
||
h323AttributesQ931BearerCapability and
|
||
h323AttributesInformationTransferCapability."
|
||
|
||
REVISION "200305050000Z"
|
||
DESCRIPTION "Added h323AttributesDirectGatewayCallHost. Removed
|
||
h323DirectGatewayCallHost, h323DirectGatewayCallPort,
|
||
h323DirectGatewayCallDhcpSiteSpecificCode and
|
||
h323DirectGatewayCallStaticPort."
|
||
|
||
REVISION "200303040000Z"
|
||
DESCRIPTION "Creation"
|
||
::= { h323 5 }
|
||
|
||
-- *************************************************************************
|
||
-- General H323 signaling configuration
|
||
-- *************************************************************************
|
||
|
||
h323AttributesMIBObjects OBJECT IDENTIFIER ::= { h323AttributesMIB 1 }
|
||
h323AttributesConformance OBJECT IDENTIFIER ::= { h323AttributesMIB 2 }
|
||
|
||
|
||
-- *************************************************************************
|
||
-- H.323 Q.931 attributes
|
||
-- *************************************************************************
|
||
|
||
h323AttributesQ931 OBJECT IDENTIFIER ::= { h323AttributesMIBObjects 1 }
|
||
|
||
h323AttributesQ931BearerCapability OBJECT IDENTIFIER ::= { h323AttributesQ931 5 }
|
||
|
||
h323AttributesInformationTransferCapability OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
speech(0),
|
||
unrestrictedDigitalInformation(1),
|
||
restrictedDigitalInformation(2),
|
||
audio31kHz(3),
|
||
udita(4),
|
||
video(5)
|
||
}
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION "Indicates the type of calls made by the H.323 unit. This value is used to set the
|
||
information transfer capability field of the bearer capability element of the SETUP
|
||
message (Q.931 header).
|
||
|
||
This information may help the called endpoint to take actions based on the nature of the
|
||
media stream to be established (voice-only call or data call or video call). This
|
||
information may impact the called endpoint on its decision to accept the call. For
|
||
example, a SCN gateway may not have access to enough bandwidth in order to accept a new IP
|
||
to SCN data call.
|
||
|
||
For calls between endpoints that are both on the IP network, this information may be
|
||
ignored by the called endpoint. This information is mostly used by SCN gateways and ISDN
|
||
gateways. The value of this variable should be changed only when necessary, in order to
|
||
adapt to third-party systems.
|
||
|
||
When receiving a call, this H.323 unit ignores the value of the information transfer
|
||
capability field.
|
||
|
||
speech : Indicates a voice-only call.
|
||
|
||
unrestrictedDigitalInformation : Unrestricted Digital Information (64 kbps). Indicates an
|
||
audiovisual call.
|
||
|
||
restrictedDigitalInformation : Restricted Digital Information (56 kbps). Indicates an
|
||
audiovisual call.
|
||
|
||
audio31kHz : 3.1 kHz audio. Indicates a voice-only call.
|
||
|
||
udita : Unrestricted Digital Information with
|
||
Tones/Announcements. Indicates an audiovisual call.
|
||
|
||
video : Indicates an audiovisual call.
|
||
|
||
'speech' and 'audio31kHz' are the choices that best represent the capabilities of this
|
||
H.323 unit.
|
||
|
||
Even though this H.323 unit does not support any video capability,
|
||
'unrestrictedDigitalInformation', 'restrictedDigitalInformation', 'udita' and 'video'
|
||
are provided in order to increase interoperability with third-party systems.
|
||
|
||
'unrestrictedDigitalInformation' is the default value for backward compatibility issues.
|
||
|
||
Please refer to ITU-T Recommendation Q.931 and ITU-T Recommendation H.225.0 for more
|
||
information on bearer capabilities."
|
||
DEFVAL { unrestrictedDigitalInformation }
|
||
::= { h323AttributesQ931BearerCapability 5 }
|
||
|
||
|
||
-- *********************************************************************
|
||
-- H.323 Signaling attributes table
|
||
-- *********************************************************************
|
||
|
||
h323AttributesQ931CalledPartyNumberTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF H323AttributesQ931CalledPartyNumberEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION "This table holds the configuration for the 'called party number' information
|
||
element. This information element is used by H.323 units. This configuration
|
||
applies to both terminal and gateway lines."
|
||
::= { h323AttributesQ931 15 }
|
||
|
||
h323AttributesQ931CalledPartyNumberEntry OBJECT-TYPE
|
||
SYNTAX H323AttributesQ931CalledPartyNumberEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION "A row in the h323AttributesQ931CalledPartyNumberTable. It contains the
|
||
configuration for the 'called party number' information element."
|
||
INDEX {
|
||
h323AttributesCalledPartyNumberIndex
|
||
}
|
||
::= { h323AttributesQ931CalledPartyNumberTable 1 }
|
||
|
||
H323AttributesQ931CalledPartyNumberEntry ::= SEQUENCE
|
||
{
|
||
h323AttributesCalledPartyNumberIndex Unsigned32,
|
||
h323AttributesCalledPartyNumberEnable MxEnableState,
|
||
h323AttributesCalledPartyNumberDigitMap OCTET STRING,
|
||
h323AttributesCalledPartyNumberTypeOfNumber INTEGER
|
||
}
|
||
|
||
h323AttributesCalledPartyNumberIndex OBJECT-TYPE
|
||
SYNTAX Unsigned32
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "Index of the h323AttributesQ931CalledPartyNumberTable."
|
||
::= { h323AttributesQ931CalledPartyNumberEntry 1 }
|
||
|
||
h323AttributesCalledPartyNumberEnable OBJECT-TYPE
|
||
SYNTAX MxEnableState
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION "This variable is related to the 'called party number' information element
|
||
(Q.931 header of the SETUP message).
|
||
|
||
When all the digit maps are disabled, the 'type of number' field is set to
|
||
'National number' and the 'numbering plan identification' field is set to
|
||
'ISDN/telephony numbering plan'.
|
||
|
||
When one or more digit maps are enabled but there is no match between the
|
||
number dialed by the local user and the digit maps that are enabled, the
|
||
'type of number' and the 'numbering plan identification' fields are both set
|
||
to 'Unknown'.
|
||
|
||
disable : the digit map is not used to set the value of the 'type of number'
|
||
field.
|
||
|
||
enable : the digit map is used to set the value of the 'type of number'
|
||
field."
|
||
DEFVAL { disable }
|
||
::= { h323AttributesQ931CalledPartyNumberEntry 5 }
|
||
|
||
h323AttributesCalledPartyNumberDigitMap OBJECT-TYPE
|
||
SYNTAX OCTET STRING (SIZE(0..63))
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION "This variable is related to the 'called party number' information element
|
||
(Q.931 header of the SETUP message).
|
||
|
||
This digit map is associated with a 'type of number' value.
|
||
|
||
At the beginning of an outgoing call, the destination of the call is compared
|
||
with the digit maps from this table. The destination of the call is the number
|
||
dialed by the local user. If there is a match, the 'type of number' value
|
||
(associated with the matching digit map) is used to set the 'type of number'
|
||
field. Only the digit maps that are enabled are used in the comparison."
|
||
DEFVAL { "" }
|
||
::= { h323AttributesQ931CalledPartyNumberEntry 10 }
|
||
|
||
h323AttributesCalledPartyNumberTypeOfNumber OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
internationalNumber(0),
|
||
nationalNumber(1),
|
||
subscriberNumber(2),
|
||
privateNumber(3),
|
||
unknown(4)
|
||
}
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION "This variable is related to the 'called party number' information element
|
||
(Q.931 header of the SETUP message).
|
||
|
||
This variable indicates the 'type of number' value associated with a digit map.
|
||
|
||
internationalNumber : indicates that the call destination is an international
|
||
number. An international number consists of a Country Code
|
||
(CC), an optional National Destination Code (NDC) followed
|
||
by a Subscriber Number (SN). For this value, the
|
||
'type of number' field is set to 'International number' and
|
||
the 'numbering plan identification' field is set to
|
||
'ISDN/telephony numbering plan'.
|
||
|
||
nationalNumber : indicates that the call destination is a national number.
|
||
A national number consists of a National Destination Code
|
||
(NDC) followed by a Subscriber Number (SN). For this value,
|
||
the 'type of number' field is set to 'National number' and
|
||
the 'numbering plan identification' field is set to
|
||
'ISDN/telephony numbering plan'.
|
||
|
||
subscriberNumber : indicates that the call destination is a local number. A
|
||
subscriber number identifies a unique subscriber in a
|
||
network or a numbering area. For this value, the
|
||
'type of number' field is set to 'Subscriber number' and
|
||
the 'numbering plan identification' field is set to
|
||
'ISDN/telephony numbering plan'.
|
||
|
||
privateNumber : indicates that the call destination is a private number.
|
||
For this value, the 'type of number' field is set to
|
||
'Unknown' and the 'numbering plan identification' field
|
||
is set to 'Private numbering plan'.
|
||
|
||
unknown : indicates that the call destination is a number specific to
|
||
a network. The number is part of a dialing plan specific to
|
||
some network. For this value, the 'type of number' and the
|
||
'numbering plan identification' fields are set to 'Unknown'.
|
||
|
||
Please refer to ITU-T Recommendation E.164 for more information on
|
||
international, national and subscriber numbers.
|
||
|
||
Please refer to ITU-T Recommendation Q.931 for more information on the
|
||
'called party number' information element."
|
||
DEFVAL { nationalNumber }
|
||
::= { h323AttributesQ931CalledPartyNumberEntry 15 }
|
||
|
||
|
||
-- *************************************************************************
|
||
-- H.323 Signaling attributes table
|
||
-- *************************************************************************
|
||
|
||
h323IfSignalingAttributesTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF H323IfSignalingAttributesEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION "This table holds signaling attributes of a H.323 unit. This configuration
|
||
applies to both terminal and gateway lines.
|
||
|
||
Each row is used to configure the signaling attributes of one line."
|
||
::= { h323AttributesMIBObjects 5 }
|
||
|
||
h323IfSignalingAttributesEntry OBJECT-TYPE
|
||
SYNTAX H323IfSignalingAttributesEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION "Each row is used to configure the signaling attributes of one line."
|
||
INDEX { ifIndex }
|
||
::= { h323IfSignalingAttributesTable 1 }
|
||
|
||
H323IfSignalingAttributesEntry ::= SEQUENCE
|
||
{
|
||
h323AttributesEarlyH245Enable MxEnableState,
|
||
h323AttributesH245TunnelingEnable MxEnableState,
|
||
h323AttributesFastConnectEnable MxEnableState,
|
||
h323AttributesParallelH245Enable MxEnableState,
|
||
h323AttributesVoiceCapabilitySendingMethod INTEGER
|
||
}
|
||
|
||
h323AttributesEarlyH245Enable OBJECT-TYPE
|
||
SYNTAX MxEnableState
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION "With the early H.245 procedure, the line includes its H.245 address in the SETUP
|
||
message (when making a call) or in the CONNECT message (when receiving a call).
|
||
This H.245 address may be used by the remote endpoint to open a H.245
|
||
connection. The H.245 connection may be opened before the call is connected,
|
||
thus the qualification of 'early' H.245.
|
||
|
||
disable : the line does not use the early H.245 procedure.
|
||
|
||
enable : the line uses the early H.245 procedure."
|
||
DEFVAL { enable }
|
||
::= { h323IfSignalingAttributesEntry 5 }
|
||
|
||
h323AttributesH245TunnelingEnable OBJECT-TYPE
|
||
SYNTAX MxEnableState
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION "When tunneling is enabled, the line sends H.245 messages within Q.931 messages.
|
||
|
||
When H.245 is enabled and the line is the calling endpoint:
|
||
|
||
- The line offers the use of H.245 tunneling by setting the h245Tunneling
|
||
field to true in the SETUP message.
|
||
|
||
- If the called endpoint accepts the use of H.245 tunneling, the line sets
|
||
the h245Tunneling field to true in every subsequent Q.931 messages.
|
||
|
||
- If the called endpoint refuses the use of H.245 tunneling, the line stops
|
||
using H.245 tunneling. The line considers the H.245 messages sent in the
|
||
SETUP message as ignored by the called endpoint.
|
||
|
||
When H.245 is disabled and the line is the calling endpoint:
|
||
|
||
- The line does not offer the use of H.245 tunneling. The line sets the
|
||
h245Tunneling field to false in every Q.931 messages.
|
||
|
||
When H.245 is enabled and the line is the called endpoint:
|
||
|
||
- When offered, the line accepts the use of H.245 tunneling. The line sets
|
||
the h245Tunneling field to true in the first Q.931 message sent as
|
||
response to the SETUP message. The line sets the h245Tunneling field to
|
||
true in every subsequent Q.931 messages.
|
||
|
||
When H.245 is disabled and the line is the called endpoint:
|
||
|
||
- When offered, the line refuses the use of H.245 tunneling. The line sets
|
||
the h245Tunneling field to false in every Q.931 messages.
|
||
|
||
When the line is the called endpoint, it does not use H.245 tunneling if it was
|
||
not offered by the calling endpoint.
|
||
|
||
disable : the line does not use H.245 tunneling.
|
||
|
||
enable : the line uses H.245 tunneling."
|
||
DEFVAL { disable }
|
||
::= { h323IfSignalingAttributesEntry 10 }
|
||
|
||
h323AttributesFastConnectEnable OBJECT-TYPE
|
||
SYNTAX MxEnableState
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION "The Fast Connect procedure allows two H.323 endpoints to establish a call with
|
||
as few as one round-trip message exchange, enabling immediate media stream
|
||
delivery upon call connection.
|
||
|
||
When making a call, the line includes the fastStart element in the SETUP
|
||
message.
|
||
|
||
When receiving a call, the line includes the fastStart element in the ALERTING
|
||
message.
|
||
|
||
The fastStart element contains the voice and data capabilities supported by the
|
||
line.
|
||
|
||
disable : the line does not use the Fast Connect procedure.
|
||
|
||
enable : the line uses the Fast Connect procedure."
|
||
DEFVAL { enable }
|
||
::= { h323IfSignalingAttributesEntry 15 }
|
||
|
||
h323AttributesParallelH245Enable OBJECT-TYPE
|
||
SYNTAX MxEnableState
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION "The parallel H.245 procedure allows a line to include all the following elements
|
||
in the SETUP message:
|
||
|
||
- fastStart channels
|
||
|
||
- terminalCapabilitySet message
|
||
|
||
- masterSlaveDetermination message
|
||
|
||
The terminalCapabilitySet and masterSlaveDetermination messages are included in
|
||
the parallelH245Control field of the SETUP message.
|
||
|
||
At the same time as sending fastStart channels, the parallel H.245 procedure is
|
||
useful to send capabilities that can<61>t be described in a fastStart channel.
|
||
Examples of such capabilities are the UserInputIndication capability and the RTP
|
||
payload types. Also, the parallel H.245 procedure accelerates the call
|
||
establishment when the called endpoint doesn<73>t support the Fast Connect
|
||
procedure.
|
||
|
||
In order to include a parallelH245Control field in the SETUP message, the
|
||
Fast Connect procedure must be enabled. See the h323AttributesFastConnectEnable
|
||
variable.
|
||
|
||
disable : the line does not use the parallel H.245 procedure.
|
||
|
||
enable : the line uses the parallel H.245 procedure."
|
||
DEFVAL { disable }
|
||
::= { h323IfSignalingAttributesEntry 20 }
|
||
|
||
h323AttributesVoiceCapabilitySendingMethod OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
abbreviated(0),
|
||
detailed(1)
|
||
}
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION "Indicates how the line constructs the fastStart element and the
|
||
terminalCapabilitySet message. This variable applies only to the fastStart
|
||
element of the SETUP message. This applies to all the terminalCapabilitySet
|
||
messages. This variable applies only to voice capabilities.
|
||
|
||
abbreviated : In the fastStart element, for each voice capability enabled, the
|
||
line sends a forward OpenLogicalChannel structure with the minimum
|
||
packetization period and a reverse OpenLogicalChannel structure
|
||
with the maximum packetization period.
|
||
|
||
In the terminalCapabilitySet message, for each voice capability
|
||
enabled, the line sends a 'transmit and receive' AudioCapability
|
||
structure with the maximum packetization period.
|
||
|
||
detailed : In the fastStart element, for each voice capability enabled, the
|
||
line sends a forward and a reverse OpenLogicalChannel structure
|
||
for each packetization period step.
|
||
|
||
In the terminalCapabilitySet message, for each voice capability
|
||
enabled, the line sends a 'transmit and receive' AudioCapability
|
||
structure for each packetization period step.
|
||
|
||
Each voice capability is configured with a minimum packetization period and a
|
||
maximum packetization period. The following table explains the concept of
|
||
packetization period step.
|
||
|
||
Voice capability family Packetization period step
|
||
======================= =========================
|
||
G.711 One packetization period step at every 10 ms between
|
||
the minimum and the maximum packetization periods. For
|
||
example, if the minimum packetization period is 10 ms
|
||
and the maximum packetization period is 30 ms, the
|
||
steps are 10, 20 and 30.
|
||
|
||
G.729 One packetization period step at every 10 ms between
|
||
the minimum and the maximum packetization periods. For
|
||
example, if the minimum packetization period is 40 ms
|
||
and the maximum packetization period is 50 ms, the
|
||
steps are 40 and 50.
|
||
|
||
G.723 One packetization period step at every 30 ms between
|
||
the minimum and the maximum packetization periods. For
|
||
example, if the minimum packetization period is 60 ms
|
||
and the maximum packetization period is 120 ms, the
|
||
steps are 60, 90 and 120.
|
||
|
||
The line can send a maximum of 20 voice capabilities:
|
||
|
||
- fastStart element: a maximum of 40 openLogicalChannel structures can be
|
||
sent in the fastStart element (20 forward openLogicalChannel structures
|
||
and 20 reverse openLogicalChannel structures). Each voice capability is
|
||
described by one forward and one reverse openLogicalChannel structure.
|
||
|
||
- terminalCapabilitySet message: a maximum of 20 AudioCapability structures
|
||
can be sent in the terminalCapabilitySet message. Each voice capability is
|
||
described by one AudioCapability structure.
|
||
|
||
If more than 20 voice capabilities are enabled by the configuration, only the
|
||
first 20 voice capabilities are sent. This restriction only applies to voice
|
||
capabilities and it has no impact on the non-voice capabilities."
|
||
DEFVAL { detailed }
|
||
::= { h323IfSignalingAttributesEntry 25 }
|
||
|
||
|
||
-- *************************************************************************
|
||
-- H.323 telephony attributes table
|
||
-- *************************************************************************
|
||
|
||
h323IfTelephonyAttributesTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF H323IfTelephonyAttributesEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION "This table holds telephony attributes of a H.323 unit. This configuration
|
||
applies to both terminal and gateway lines.
|
||
|
||
Each row is used to configure the telephony attributes of one line."
|
||
::= { h323AttributesMIBObjects 10 }
|
||
|
||
h323IfTelephonyAttributesEntry OBJECT-TYPE
|
||
SYNTAX H323IfTelephonyAttributesEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION "Each row is used to configure the telephony attributes of one line."
|
||
INDEX { ifIndex }
|
||
::= { h323IfTelephonyAttributesTable 1 }
|
||
|
||
H323IfTelephonyAttributesEntry ::= SEQUENCE
|
||
{
|
||
h323AttributesDirectGatewayCallEnable MxEnableState,
|
||
h323AttributesDirectGatewayCallHost MxIpAddress
|
||
}
|
||
|
||
h323AttributesDirectGatewayCallEnable OBJECT-TYPE
|
||
SYNTAX MxEnableState
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION "The 'Direct Gateway Call' is a Mediatrix proprietary procedure. The line is
|
||
configured with the IP address of a gateway.
|
||
|
||
This procedure applies only to lines that are not configured to register:
|
||
|
||
- The unit is configured with the multiple registration method and the
|
||
registration for the line is disabled.
|
||
|
||
OR
|
||
|
||
- The unit is configured with the none registration method.
|
||
|
||
This procedure allows the use of a gateway without the presence of a
|
||
gatekeeper. The user simply dials a telephone number. The new outgoing call
|
||
goes directly to the gateway. The telephone number is the call destination on
|
||
the SCN side. This procedure is not used if the user dials an IP address before
|
||
dialing a telephone number.
|
||
|
||
disable : the line does not use the 'Direct Gateway Call' procedure.
|
||
|
||
enable : the line uses the 'Direct Gateway Call' procedure."
|
||
DEFVAL { disable }
|
||
::= { h323IfTelephonyAttributesEntry 5 }
|
||
|
||
h323AttributesDirectGatewayCallHost OBJECT-TYPE
|
||
SYNTAX MxIpAddress
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION "The IP address of the gateway used in the 'Direct Gateway Call' procedure.
|
||
|
||
The 'Direct Gateway Call' is a Mediatrix proprietary procedure. It allows the
|
||
use of a gateway without the presence of a gatekeeper. The user simply dials a
|
||
telephone number. The new outgoing call goes directly to the gateway. The
|
||
telephone number is the call destination on the SCN side. This procedure is not
|
||
used if the user dials an IP address before dialing a telephone number.
|
||
|
||
This procedure applies only to lines with the following configuration:
|
||
|
||
- Multiple registration method
|
||
|
||
- Registration disabled"
|
||
DEFVAL { "" }
|
||
::= { h323IfTelephonyAttributesEntry 10 }
|
||
|
||
-- *************************************************************************
|
||
-- Conformance information
|
||
-- *************************************************************************
|
||
|
||
h323AttributesCompliances OBJECT IDENTIFIER ::= { h323AttributesConformance 1 }
|
||
|
||
h323AttributesBasicComplVer1 MODULE-COMPLIANCE
|
||
STATUS current
|
||
DESCRIPTION "This is a list of conformance groups. These conformance groups contain the name
|
||
of objects necessary to adequately configure a H.323 unit."
|
||
MODULE -- MX-H323-ATTRIBUTES-MIB
|
||
MANDATORY-GROUPS {
|
||
h323AttributesSignalingGroupVer1,
|
||
h323AttributesTelephonyGroupVer1,
|
||
h323AttributesQ931GroupVer1
|
||
}
|
||
::= { h323AttributesCompliances 5 }
|
||
|
||
-- *************************************************************************
|
||
-- MIB variable grouping
|
||
-- *************************************************************************
|
||
|
||
h323AttributesGroups OBJECT IDENTIFIER ::= { h323AttributesConformance 2 }
|
||
|
||
h323AttributesSignalingGroupVer1 OBJECT-GROUP
|
||
OBJECTS {
|
||
h323AttributesEarlyH245Enable,
|
||
h323AttributesH245TunnelingEnable,
|
||
h323AttributesFastConnectEnable,
|
||
h323AttributesParallelH245Enable,
|
||
h323AttributesVoiceCapabilitySendingMethod
|
||
}
|
||
STATUS current
|
||
DESCRIPTION "A list of objects used to configure some call signaling features of a H.323
|
||
unit."
|
||
::= { h323AttributesGroups 5 }
|
||
|
||
h323AttributesTelephonyGroupVer1 OBJECT-GROUP
|
||
OBJECTS {
|
||
h323AttributesDirectGatewayCallEnable,
|
||
h323AttributesDirectGatewayCallHost
|
||
}
|
||
STATUS current
|
||
DESCRIPTION "A list of objects used to configure the 'Direct Gateway Call' procedure for a
|
||
H.323 unit."
|
||
::= { h323AttributesGroups 10 }
|
||
|
||
h323AttributesQ931GroupVer1 OBJECT-GROUP
|
||
OBJECTS {
|
||
h323AttributesInformationTransferCapability,
|
||
h323AttributesCalledPartyNumberIndex,
|
||
h323AttributesCalledPartyNumberEnable,
|
||
h323AttributesCalledPartyNumberDigitMap,
|
||
h323AttributesCalledPartyNumberTypeOfNumber
|
||
}
|
||
STATUS current
|
||
DESCRIPTION "A list of objects used to configure some Q.931 features of a H.323 unit."
|
||
::= { h323AttributesGroups 15 }
|
||
|
||