11483 lines
232 KiB
Plaintext
11483 lines
232 KiB
Plaintext
SNMPSERVER-MIB DEFINITIONS ::= BEGIN
|
|
|
|
|
|
IMPORTS
|
|
MODULE-IDENTITY, OBJECT-TYPE, NOTIFICATION-TYPE, TimeTicks, Counter32, Counter64, Unsigned32, dod, mib-2
|
|
FROM SNMPv2-SMI
|
|
DisplayString
|
|
FROM SNMPv2-TC;
|
|
|
|
internet OBJECT IDENTIFIER ::= { dod 1 }
|
|
|
|
mgmt OBJECT IDENTIFIER ::= { internet 2 }
|
|
|
|
mib-2 OBJECT IDENTIFIER ::= { mgmt 1 }
|
|
|
|
system OBJECT IDENTIFIER ::= { mib-2 1 }
|
|
|
|
sysDescr OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION ""
|
|
::= { system 1 }
|
|
|
|
sysObjectID OBJECT-TYPE
|
|
SYNTAX OBJECT IDENTIFIER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION ""
|
|
::= { system 2 }
|
|
|
|
sysUpTime OBJECT-TYPE
|
|
SYNTAX TimeTicks
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION ""
|
|
::= { system 3 }
|
|
|
|
sysContact OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION ""
|
|
::= { system 4 }
|
|
|
|
sysName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION ""
|
|
::= { system 5 }
|
|
|
|
sysLocation OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION ""
|
|
::= { system 6 }
|
|
|
|
private OBJECT IDENTIFIER ::= { internet 4 }
|
|
|
|
enterprises OBJECT IDENTIFIER ::= { private 1 }
|
|
|
|
tecnairlv OBJECT IDENTIFIER ::= { enterprises 53332 }
|
|
|
|
node1 OBJECT IDENTIFIER ::= { tecnairlv 1 }
|
|
|
|
traps1 OBJECT IDENTIFIER ::= { node1 0 }
|
|
|
|
generalAlTrap_1 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
generalAl_1
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "General alarams"
|
|
::= { traps1 1 }
|
|
|
|
notCriticalAlTrap_1 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
notCriticalAl_1
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Not critical alarms"
|
|
::= { traps1 2 }
|
|
|
|
criticalAlTrap_1 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
criticalAl_1
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Critical alarms"
|
|
::= { traps1 3 }
|
|
|
|
fansAlTrap_1 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
fansAl_1
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Fans alarms"
|
|
::= { traps1 4 }
|
|
|
|
compAlTrap_1 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
compAl_1
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Compressors alarms"
|
|
::= { traps1 5 }
|
|
|
|
temperatureAlTrap_1 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
temperatureAl_1
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Temperature alarms"
|
|
::= { traps1 6 }
|
|
|
|
humidityAlTrap_1 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
humidityAl_1
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Humidity alarms"
|
|
::= { traps1 7 }
|
|
|
|
damperAlTrap_1 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
damperAl_1
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Damper status alarm"
|
|
::= { traps1 8 }
|
|
|
|
fireSmokeAlTrap_1 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
fireSmokeAl_1
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Fire/Smoke alarm"
|
|
::= { traps1 9 }
|
|
|
|
genSeriousAlTrap_1 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
genSeriousAl_1
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Critical generic alarm"
|
|
::= { traps1 10 }
|
|
|
|
fansGenAlTrap_1 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
fansGenAl_1
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "General supply fans alarm"
|
|
::= { traps1 11 }
|
|
|
|
f1GeneralAlTrap_1 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
f1GeneralAl_1
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Fan general alarm 1"
|
|
::= { traps1 12 }
|
|
|
|
f1PowerAlTrap_1 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
f1PowerAl_1
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Phase failure/undervolt.1"
|
|
::= { traps1 13 }
|
|
|
|
f1CommAlTrap_1 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
f1CommAl_1
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Communication 1"
|
|
::= { traps1 14 }
|
|
|
|
f1HighTempAlTrap_1 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
f1HighTempAl_1
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Power mod overheated 1"
|
|
::= { traps1 15 }
|
|
|
|
f1NetComAlTrap_1 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
f1NetComAl_1
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Master/Slave com. 1"
|
|
::= { traps1 16 }
|
|
|
|
f1InvRegAlTrap_1 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
f1InvRegAl_1
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Regulation module 1"
|
|
::= { traps1 17 }
|
|
|
|
f1HighMotTempAlTrap_1 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
f1HighMotTempAl_1
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Motor overheated 1"
|
|
::= { traps1 18 }
|
|
|
|
f1HallSensAlTrap_1 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
f1HallSensAl_1
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Hall sensor error 1"
|
|
::= { traps1 19 }
|
|
|
|
f1OverloadAlTrap_1 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
f1OverloadAl_1
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Locked motor 1"
|
|
::= { traps1 20 }
|
|
|
|
f1LowDCAlTrap_1 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
f1LowDCAl_1
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Low DC 1"
|
|
::= { traps1 21 }
|
|
|
|
f2GeneralAlTrap_1 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
f2GeneralAl_1
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Fan general alarm 2"
|
|
::= { traps1 22 }
|
|
|
|
f2PowerAlTrap_1 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
f2PowerAl_1
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Phase failure/undervolt.2"
|
|
::= { traps1 23 }
|
|
|
|
f2CommAlTrap_1 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
f2CommAl_1
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Communication 2"
|
|
::= { traps1 24 }
|
|
|
|
f2HighTempAlTrap_1 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
f2HighTempAl_1
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Power mod overheated 2"
|
|
::= { traps1 25 }
|
|
|
|
f2NetComAlTrap_1 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
f2NetComAl_1
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Master/Slave com. 2"
|
|
::= { traps1 26 }
|
|
|
|
f2InvRegAlTrap_1 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
f2InvRegAl_1
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Regulation module 2"
|
|
::= { traps1 27 }
|
|
|
|
f2HighMotTempAlTrap_1 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
f2HighMotTempAl_1
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Motor overheated 2"
|
|
::= { traps1 28 }
|
|
|
|
f2HallSensAlTrap_1 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
f2HallSensAl_1
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Hall sensor error 2"
|
|
::= { traps1 29 }
|
|
|
|
f2OverloadAlTrap_1 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
f2OverloadAl_1
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Locked motor 2"
|
|
::= { traps1 30 }
|
|
|
|
f2LowDCAlTrap_1 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
f2LowDCAl_1
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Low DC 2"
|
|
::= { traps1 31 }
|
|
|
|
f3GeneralAlTrap_1 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
f3GeneralAl_1
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Fan general alarm 3"
|
|
::= { traps1 32 }
|
|
|
|
f3PowerAlTrap_1 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
f3PowerAl_1
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Phase failure/undervolt.3"
|
|
::= { traps1 33 }
|
|
|
|
f3CommAlTrap_1 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
f3CommAl_1
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Communication 3"
|
|
::= { traps1 34 }
|
|
|
|
f3HighTempAlTrap_1 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
f3HighTempAl_1
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Power mod overheated 3"
|
|
::= { traps1 35 }
|
|
|
|
f3NetComAlTrap_1 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
f3NetComAl_1
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Master/Slave com. 3"
|
|
::= { traps1 36 }
|
|
|
|
f3InvRegAlTrap_1 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
f3InvRegAl_1
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Regulation module 3"
|
|
::= { traps1 37 }
|
|
|
|
f3HighMotTempAlTrap_1 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
f3HighMotTempAl_1
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Motor overheated 3"
|
|
::= { traps1 38 }
|
|
|
|
f3HallSensAlTrap_1 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
f3HallSensAl_1
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Hall sensor error 3"
|
|
::= { traps1 39 }
|
|
|
|
f3OverloadAlTrap_1 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
f3OverloadAl_1
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Locked motor 3"
|
|
::= { traps1 40 }
|
|
|
|
f3LowDCAlTrap_1 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
f3LowDCAl_1
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Low DC 3"
|
|
::= { traps1 41 }
|
|
|
|
f4GeneralAlTrap_1 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
f4GeneralAl_1
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Fan general alarm 4"
|
|
::= { traps1 42 }
|
|
|
|
f4PowerAlTrap_1 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
f4PowerAl_1
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Phase failure/undervolt.4"
|
|
::= { traps1 43 }
|
|
|
|
f4CommAlTrap_1 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
f4CommAl_1
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Communication 4"
|
|
::= { traps1 44 }
|
|
|
|
f4HighTempAlTrap_1 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
f4HighTempAl_1
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Power mod overheated 4"
|
|
::= { traps1 45 }
|
|
|
|
f4NetComAlTrap_1 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
f4NetComAl_1
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Master/Slave com. 4"
|
|
::= { traps1 46 }
|
|
|
|
f4InvRegAlTrap_1 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
f4InvRegAl_1
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Regulation module 4"
|
|
::= { traps1 47 }
|
|
|
|
f4HighMotTempAlTrap_1 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
f4HighMotTempAl_1
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Motor overheated 4"
|
|
::= { traps1 48 }
|
|
|
|
f4HallSensAlTrap_1 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
f4HallSensAl_1
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Hall sensor error 4"
|
|
::= { traps1 49 }
|
|
|
|
f4OverloadAlTrap_1 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
f4OverloadAl_1
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Locked motor 4"
|
|
::= { traps1 50 }
|
|
|
|
f4LowDCAlTrap_1 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
f4LowDCAl_1
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Low DC 4"
|
|
::= { traps1 51 }
|
|
|
|
f5GeneralAlTrap_1 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
f5GeneralAl_1
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Fan general alarm 5"
|
|
::= { traps1 52 }
|
|
|
|
f5PowerAlTrap_1 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
f5PowerAl_1
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Phase failure/undervolt.5"
|
|
::= { traps1 53 }
|
|
|
|
f5CommAlTrap_1 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
f5CommAl_1
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Communication 5"
|
|
::= { traps1 54 }
|
|
|
|
f5HighTempAlTrap_1 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
f5HighTempAl_1
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Power mod overheated 5"
|
|
::= { traps1 55 }
|
|
|
|
f5NetComAlTrap_1 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
f5NetComAl_1
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Master/Slave com. 5"
|
|
::= { traps1 56 }
|
|
|
|
f5InvRegAlTrap_1 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
f5InvRegAl_1
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Regulation module 5"
|
|
::= { traps1 57 }
|
|
|
|
f5HighMotTempAlTrap_1 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
f5HighMotTempAl_1
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Motor overheated 5"
|
|
::= { traps1 58 }
|
|
|
|
f5HallSensAlTrap_1 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
f5HallSensAl_1
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Hall sensor error 5"
|
|
::= { traps1 59 }
|
|
|
|
f5OverloadAlTrap_1 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
f5OverloadAl_1
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Locked motor 5"
|
|
::= { traps1 60 }
|
|
|
|
f5LowDCAlTrap_1 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
f5LowDCAl_1
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Low DC 5"
|
|
::= { traps1 61 }
|
|
|
|
f6GeneralAlTrap_1 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
f6GeneralAl_1
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Fan general alarm 6"
|
|
::= { traps1 62 }
|
|
|
|
f6PowerAlTrap_1 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
f6PowerAl_1
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Phase failure/undervolt.6"
|
|
::= { traps1 63 }
|
|
|
|
f6CommAlTrap_1 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
f6CommAl_1
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Communication 6"
|
|
::= { traps1 64 }
|
|
|
|
f6HighTempAlTrap_1 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
f6HighTempAl_1
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Power mod overheated 6"
|
|
::= { traps1 65 }
|
|
|
|
f6NetComAlTrap_1 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
f6NetComAl_1
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Master/Slave com. 6"
|
|
::= { traps1 66 }
|
|
|
|
f6InvRegAlTrap_1 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
f6InvRegAl_1
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Regulation module 6"
|
|
::= { traps1 67 }
|
|
|
|
f6HighMotTempAlTrap_1 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
f6HighMotTempAl_1
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Motor overheated 6"
|
|
::= { traps1 68 }
|
|
|
|
f6HallSensAlTrap_1 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
f6HallSensAl_1
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Hall sensor error 6"
|
|
::= { traps1 69 }
|
|
|
|
f6OverloadAlTrap_1 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
f6OverloadAl_1
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Locked motor 6"
|
|
::= { traps1 70 }
|
|
|
|
f6LowDCAlTrap_1 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
f6LowDCAl_1
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Low DC 6"
|
|
::= { traps1 71 }
|
|
|
|
f7GeneralAlTrap_1 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
f7GeneralAl_1
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Fan general alarm 7"
|
|
::= { traps1 72 }
|
|
|
|
f7PowerAlTrap_1 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
f7PowerAl_1
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Phase failure/undervolt.7"
|
|
::= { traps1 73 }
|
|
|
|
f7CommAlTrap_1 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
f7CommAl_1
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Communication 7"
|
|
::= { traps1 74 }
|
|
|
|
f7HighTempAlTrap_1 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
f7HighTempAl_1
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Power mod overheated 7"
|
|
::= { traps1 75 }
|
|
|
|
f7NetComAlTrap_1 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
f7NetComAl_1
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Master/Slave com. 7"
|
|
::= { traps1 76 }
|
|
|
|
f7InvRegAlTrap_1 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
f7InvRegAl_1
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Regulation module 7"
|
|
::= { traps1 77 }
|
|
|
|
f7HighMotTempAlTrap_1 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
f7HighMotTempAl_1
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Motor overheated 7"
|
|
::= { traps1 78 }
|
|
|
|
f7HallSensAlTrap_1 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
f7HallSensAl_1
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Hall sensor error 7"
|
|
::= { traps1 79 }
|
|
|
|
f7OverloadAlTrap_1 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
f7OverloadAl_1
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Locked motor 7"
|
|
::= { traps1 80 }
|
|
|
|
f7LowDCAlTrap_1 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
f7LowDCAl_1
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Low DC 7"
|
|
::= { traps1 81 }
|
|
|
|
f8GeneralAlTrap_1 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
f8GeneralAl_1
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Fan general alarm 8"
|
|
::= { traps1 82 }
|
|
|
|
f8PowerAlTrap_1 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
f8PowerAl_1
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Phase failure/undervolt.8"
|
|
::= { traps1 83 }
|
|
|
|
f8CommAlTrap_1 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
f8CommAl_1
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Communication 8"
|
|
::= { traps1 84 }
|
|
|
|
f8HighTempAlTrap_1 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
f8HighTempAl_1
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Power mod overheated 8"
|
|
::= { traps1 85 }
|
|
|
|
f8NetComAlTrap_1 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
f8NetComAl_1
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Master/Slave com. 8"
|
|
::= { traps1 86 }
|
|
|
|
f8InvRegAlTrap_1 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
f8InvRegAl_1
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Regulation module 8"
|
|
::= { traps1 87 }
|
|
|
|
f8HighMotTempAlTrap_1 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
f8HighMotTempAl_1
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Motor overheated 8"
|
|
::= { traps1 88 }
|
|
|
|
f8HallSensAlTrap_1 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
f8HallSensAl_1
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Hall sensor error 8"
|
|
::= { traps1 89 }
|
|
|
|
f8OverloadAlTrap_1 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
f8OverloadAl_1
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Locked motor 8"
|
|
::= { traps1 90 }
|
|
|
|
f8LowDCAlTrap_1 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
f8LowDCAl_1
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Low DC 8"
|
|
::= { traps1 91 }
|
|
|
|
f9InverterAlTrap_1 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
f9InverterAl_1
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Fan general alarm 9"
|
|
::= { traps1 92 }
|
|
|
|
f9PowerAlTrap_1 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
f9PowerAl_1
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Phase failure/undervolt.9"
|
|
::= { traps1 93 }
|
|
|
|
f9CommAlTrap_1 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
f9CommAl_1
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Communication 9"
|
|
::= { traps1 94 }
|
|
|
|
f9HighTempAlTrap_1 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
f9HighTempAl_1
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Power mod overheated 9"
|
|
::= { traps1 95 }
|
|
|
|
f9NetComAlTrap_1 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
f9NetComAl_1
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Master/Slave com. 9"
|
|
::= { traps1 96 }
|
|
|
|
f9InvRegAlTrap_1 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
f9InvRegAl_1
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Regulation module 9"
|
|
::= { traps1 97 }
|
|
|
|
f9HighMotTempAlTrap_1 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
f9HighMotTempAl_1
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Motor overheated 9"
|
|
::= { traps1 98 }
|
|
|
|
f9HallSensAlTrap_1 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
f9HallSensAl_1
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Hall sensor error 9"
|
|
::= { traps1 99 }
|
|
|
|
f9OverloadAlTrap_1 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
f9OverloadAl_1
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Locked motor 9"
|
|
::= { traps1 100 }
|
|
|
|
f9LowDCAlTrap_1 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
f9LowDCAl_1
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Low DC 9"
|
|
::= { traps1 101 }
|
|
|
|
f10GeneralAlTrap_1 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
f10GeneralAl_1
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Fan general alarm 10"
|
|
::= { traps1 102 }
|
|
|
|
f10PowerAlTrap_1 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
f10PowerAl_1
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Phase failure/undervolt.10"
|
|
::= { traps1 103 }
|
|
|
|
f10CommAlTrap_1 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
f10CommAl_1
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Communication 10"
|
|
::= { traps1 104 }
|
|
|
|
f10HighTempAlTrap_1 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
f10HighTempAl_1
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Power mod overheated 10"
|
|
::= { traps1 105 }
|
|
|
|
f10NetComAlTrap_1 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
f10NetComAl_1
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Master/Slave com. 10"
|
|
::= { traps1 106 }
|
|
|
|
f10InvRegAlTrap_1 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
f10InvRegAl_1
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Regulation module 10"
|
|
::= { traps1 107 }
|
|
|
|
f10HighMotTAlTrap_1 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
f10HighMotTAl_1
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Motor overheated 10"
|
|
::= { traps1 108 }
|
|
|
|
f10HallSensAlTrap_1 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
f10HallSensAl_1
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Hall sensor error 10"
|
|
::= { traps1 109 }
|
|
|
|
f10OverloadAlTrap_1 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
f10OverloadAl_1
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Locked motor 10"
|
|
::= { traps1 110 }
|
|
|
|
f10LowDCAlTrap_1 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
f10LowDCAl_1
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Low DC 10"
|
|
::= { traps1 111 }
|
|
|
|
retTempProbAlTrap_1 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
retTempProbAl_1
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Return temperature probe"
|
|
::= { traps1 112 }
|
|
|
|
supTempProbAlTrap_1 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
supTempProbAl_1
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Supply temperature probe"
|
|
::= { traps1 113 }
|
|
|
|
retHumProbAlTrap_1 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
retHumProbAl_1
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Return humidity probe"
|
|
::= { traps1 114 }
|
|
|
|
supHumProbAlTrap_1 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
supHumProbAl_1
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Supply humidity probe"
|
|
::= { traps1 115 }
|
|
|
|
airPrSensorAlTrap_1 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
airPrSensorAl_1
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Air diff.pressure probe"
|
|
::= { traps1 116 }
|
|
|
|
watIN1ProbAlTrap_1 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
watIN1ProbAl_1
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Water temp. IN1 probe"
|
|
::= { traps1 117 }
|
|
|
|
watOUT1ProbAlTrap_1 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
watOUT1ProbAl_1
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Water temp. OUT1 probe"
|
|
::= { traps1 118 }
|
|
|
|
watIN2ProbAlTrap_1 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
watIN2ProbAl_1
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Water temp. IN2 probe"
|
|
::= { traps1 119 }
|
|
|
|
watOUT2ProbAlTrap_1 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
watOUT2ProbAl_1
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Water temp. OUT2 probe"
|
|
::= { traps1 120 }
|
|
|
|
watFlw1ProbAlTrap_1 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
watFlw1ProbAl_1
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Water flow1/T.liquid1 pr."
|
|
::= { traps1 121 }
|
|
|
|
watFlw2ProbAlTrap_1 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
watFlw2ProbAl_1
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Water flow2/T.liquid2 pr."
|
|
::= { traps1 122 }
|
|
|
|
dFPSGenAlTrap_1 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
dFPSGenAl_1
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Filter diff.press. probe"
|
|
::= { traps1 123 }
|
|
|
|
dFPSBrokenAlTrap_1 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
dFPSBrokenAl_1
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Breakdown alarm"
|
|
::= { traps1 124 }
|
|
|
|
dFPSCablingAlTrap_1 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
dFPSCablingAl_1
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Wiring alarm"
|
|
::= { traps1 125 }
|
|
|
|
dFPSRangeAlTrap_1 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
dFPSRangeAl_1
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Pressure range alarm"
|
|
::= { traps1 126 }
|
|
|
|
dFPSADCAlTrap_1 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
dFPSADCAl_1
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "ADC overload alarm"
|
|
::= { traps1 127 }
|
|
|
|
dFPSSettingAlTrap_1 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
dFPSSettingAl_1
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Calibration alarm"
|
|
::= { traps1 128 }
|
|
|
|
dFPSDCOAlTrap_1 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
dFPSDCOAl_1
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "DCO alarm"
|
|
::= { traps1 129 }
|
|
|
|
dFPSWatchdogAlTrap_1 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
dFPSWatchdogAl_1
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Watchdog alarm"
|
|
::= { traps1 130 }
|
|
|
|
dFPSCommAlTrap_1 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
dFPSCommAl_1
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Communication alarm"
|
|
::= { traps1 131 }
|
|
|
|
invCompGenAlTrap_1 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
invCompGenAl_1
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "DC inverter general alarm"
|
|
::= { traps1 132 }
|
|
|
|
invCompCommAlTrap_1 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
invCompCommAl_1
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Inverter communication"
|
|
::= { traps1 133 }
|
|
|
|
invCompAlCode1Trap_1 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
invCompAlCode1_1
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "DC Inverter alarm code 1"
|
|
::= { traps1 134 }
|
|
|
|
invCompAlCode2Trap_1 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
invCompAlCode2_1
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "DC Inverter alarm code 2"
|
|
::= { traps1 135 }
|
|
|
|
invCompAlCode3Trap_1 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
invCompAlCode3_1
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "DC Inverter alarm code 3"
|
|
::= { traps1 136 }
|
|
|
|
invCompAlCode4Trap_1 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
invCompAlCode4_1
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "DC Inverter alarm code 4"
|
|
::= { traps1 137 }
|
|
|
|
invCompAlCode5Trap_1 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
invCompAlCode5_1
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "DC Inverter alarm code 5"
|
|
::= { traps1 138 }
|
|
|
|
c1ThermAlTrap_1 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
c1ThermAl_1
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "C1 Thermal alarm"
|
|
::= { traps1 139 }
|
|
|
|
c1HighPresAlTrap_1 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
c1HighPresAl_1
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "C1 High pressure alarm"
|
|
::= { traps1 140 }
|
|
|
|
c1LowPresAlTrap_1 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
c1LowPresAl_1
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "C1 Low pressure alarm"
|
|
::= { traps1 141 }
|
|
|
|
c1HighDischAlTrap_1 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
c1HighDischAl_1
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "C1 High discharge alarm"
|
|
::= { traps1 142 }
|
|
|
|
c1LCompRatAlTrap_1 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
c1LCompRatAl_1
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "C1 low compresion alarm"
|
|
::= { traps1 143 }
|
|
|
|
condenser1AlTrap_1 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
condenser1Al_1
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Condenser 1 general alarm"
|
|
::= { traps1 144 }
|
|
|
|
c1WatFlowAlTrap_1 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
c1WatFlowAl_1
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Condenser 1 flow alarm"
|
|
::= { traps1 145 }
|
|
|
|
eEV1GenAlTrap_1 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
eEV1GenAl_1
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "EEV1 general alarm"
|
|
::= { traps1 146 }
|
|
|
|
eEV1CommAlTrap_1 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
eEV1CommAl_1
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "EEV1 communication alarm"
|
|
::= { traps1 147 }
|
|
|
|
eEV1SuctProbAlTrap_1 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
eEV1SuctProbAl_1
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "EEV1 suction temp. probe"
|
|
::= { traps1 148 }
|
|
|
|
eEV1EvapProbAlTrap_1 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
eEV1EvapProbAl_1
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "EEV1 evap. temp. probe"
|
|
::= { traps1 149 }
|
|
|
|
eEV1CondProbAlTrap_1 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
eEV1CondProbAl_1
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "EEV1 condens. temp. probe"
|
|
::= { traps1 150 }
|
|
|
|
eEV1DischProbAlTrap_1 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
eEV1DischProbAl_1
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "EEV1 disch. temp. probe"
|
|
::= { traps1 151 }
|
|
|
|
c2ThermAlTrap_1 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
c2ThermAl_1
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "C2 Thermal alarm"
|
|
::= { traps1 152 }
|
|
|
|
c2HighPresAlTrap_1 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
c2HighPresAl_1
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "C2 High pressure alarm"
|
|
::= { traps1 153 }
|
|
|
|
c2LowPresAlTrap_1 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
c2LowPresAl_1
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "C2 Low pressure alarm"
|
|
::= { traps1 154 }
|
|
|
|
c2HighDischAlTrap_1 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
c2HighDischAl_1
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "C2 High discharge alarm"
|
|
::= { traps1 155 }
|
|
|
|
c2LCompRatAlTrap_1 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
c2LCompRatAl_1
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "C2 low compresion alarm"
|
|
::= { traps1 156 }
|
|
|
|
condenser2AlTrap_1 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
condenser2Al_1
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Condenser 2 general alarm"
|
|
::= { traps1 157 }
|
|
|
|
c2WatFlowAlTrap_1 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
c2WatFlowAl_1
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Condenser 2 flow alarm"
|
|
::= { traps1 158 }
|
|
|
|
eEV2GenAlTrap_1 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
eEV2GenAl_1
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "EEV2 general alarm"
|
|
::= { traps1 159 }
|
|
|
|
eEV2CommAlTrap_1 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
eEV2CommAl_1
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "EEV2 communication alarm"
|
|
::= { traps1 160 }
|
|
|
|
eEV2SuctProbAlTrap_1 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
eEV2SuctProbAl_1
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "EEV2 suction temp. probe"
|
|
::= { traps1 161 }
|
|
|
|
eEV2EvapProbAlTrap_1 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
eEV2EvapProbAl_1
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "EEV2 evap. temp. probe"
|
|
::= { traps1 162 }
|
|
|
|
eEV2CondProbAlTrap_1 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
eEV2CondProbAl_1
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "EEV2 condens. temp. probe"
|
|
::= { traps1 163 }
|
|
|
|
eEV2DischProbAlTrap_1 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
eEV2DischProbAl_1
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "EEV2 disch. temp. probe"
|
|
::= { traps1 164 }
|
|
|
|
intHumidGenAlTrap_1 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
intHumidGenAl_1
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Internal humidifier alarm"
|
|
::= { traps1 165 }
|
|
|
|
cPYCommAlTrap_1 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
cPYCommAl_1
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Communication alarm"
|
|
::= { traps1 166 }
|
|
|
|
cPYMemoryAlTrap_1 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
cPYMemoryAl_1
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Memory error alarm"
|
|
::= { traps1 167 }
|
|
|
|
cPYParameterAlTrap_1 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
cPYParameterAl_1
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Parameters error alarm"
|
|
::= { traps1 168 }
|
|
|
|
cPYHighCurrAlTrap_1 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
cPYHighCurrAl_1
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Electrodes high current"
|
|
::= { traps1 169 }
|
|
|
|
cPYLowSteamAlTrap_1 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
cPYLowSteamAl_1
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Low steam product. alarm"
|
|
::= { traps1 170 }
|
|
|
|
cPYDrainAlTrap_1 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
cPYDrainAl_1
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Drain loss alarm"
|
|
::= { traps1 171 }
|
|
|
|
cPYMaintAlTrap_1 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
cPYMaintAl_1
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Maintenance hours alarm"
|
|
::= { traps1 172 }
|
|
|
|
cPYNoWaterAlTrap_1 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
cPYNoWaterAl_1
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Water loss alarm"
|
|
::= { traps1 173 }
|
|
|
|
cPYCylMaintAlTrap_1 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
cPYCylMaintAl_1
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Cylinder mainten. alarm"
|
|
::= { traps1 174 }
|
|
|
|
cPYDirtyCylAlTrap_1 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
cPYDirtyCylAl_1
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Exaust cylinder alarm"
|
|
::= { traps1 175 }
|
|
|
|
cPYFoamAlTrap_1 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
cPYFoamAl_1
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Foam presence alarm"
|
|
::= { traps1 176 }
|
|
|
|
cPYLifeTimeAlTrap_1 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
cPYLifeTimeAl_1
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Life time expired alarm"
|
|
::= { traps1 177 }
|
|
|
|
cPYHighWatLevAlTrap_1 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
cPYHighWatLevAl_1
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "High water level alarm"
|
|
::= { traps1 178 }
|
|
|
|
cPYHWatCondAlTrap_1 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
cPYHWatCondAl_1
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "High conductivity alarm"
|
|
::= { traps1 179 }
|
|
|
|
cPYConnectionAlTrap_1 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
cPYConnectionAl_1
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Connection error alarm"
|
|
::= { traps1 180 }
|
|
|
|
watPresAlTrap_1 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
watPresAl_1
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Water presence alarm"
|
|
::= { traps1 181 }
|
|
|
|
drainPumpAlTrap_1 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
drainPumpAl_1
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Drain pump alarm"
|
|
::= { traps1 182 }
|
|
|
|
elHeatAlTrap_1 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
elHeatAl_1
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Electric heater alarm"
|
|
::= { traps1 183 }
|
|
|
|
filterAlTrap_1 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
filterAl_1
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Dirty filter alarm"
|
|
::= { traps1 184 }
|
|
|
|
dryCoolerAlTrap_1 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
dryCoolerAl_1
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Dry cooler alarm"
|
|
::= { traps1 185 }
|
|
|
|
extHumidAlTrap_1 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
extHumidAl_1
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "External humidifier alarm"
|
|
::= { traps1 186 }
|
|
|
|
waterPumpAlTrap_1 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
waterPumpAl_1
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Water pump alarm"
|
|
::= { traps1 187 }
|
|
|
|
condUnitGenAlTrap_1 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
condUnitGenAl_1
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Motocondenser alarm"
|
|
::= { traps1 188 }
|
|
|
|
gasLeakAlTrap_1 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
gasLeakAl_1
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Refrigerant leak alarm"
|
|
::= { traps1 189 }
|
|
|
|
powerSupplyAlTrap_1 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
powerSupplyAl_1
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Power fault alarm"
|
|
::= { traps1 190 }
|
|
|
|
genericSoftAlTrap_1 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
genericSoftAl_1
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Not critical generic al."
|
|
::= { traps1 191 }
|
|
|
|
localNetworkAlTrap_1 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
localNetworkAl_1
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Local network alarm"
|
|
::= { traps1 192 }
|
|
|
|
regHighTempAlTrap_1 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
regHighTempAl_1
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "High regulation T.alarm"
|
|
::= { traps1 193 }
|
|
|
|
regLowTempAlTrap_1 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
regLowTempAl_1
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Low regulation T.alarm"
|
|
::= { traps1 194 }
|
|
|
|
highLimTempAlTrap_1 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
highLimTempAl_1
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "High limit temp. alarm"
|
|
::= { traps1 195 }
|
|
|
|
lowLimTempAlTrap_1 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
lowLimTempAl_1
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Low limit temp. alarm"
|
|
::= { traps1 196 }
|
|
|
|
retHighHumiAlTrap_1 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
retHighHumiAl_1
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "High room humidity alarm"
|
|
::= { traps1 197 }
|
|
|
|
retLowHumiAlTrap_1 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
retLowHumiAl_1
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Low room humidity alarm"
|
|
::= { traps1 198 }
|
|
|
|
supHighHumiAlTrap_1 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
supHighHumiAl_1
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "High supp.humidity alarm"
|
|
::= { traps1 199 }
|
|
|
|
supLowHumiAlTrap_1 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
supLowHumiAl_1
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Low supp.humidity alarm"
|
|
::= { traps1 200 }
|
|
|
|
probeMod1COMTrap_1 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
probeMod1COM_1
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Module 1 communication"
|
|
::= { traps1 201 }
|
|
|
|
probeMod1err1Trap_1 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
probeMod1err1_1
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Module 1 probe 1 alarm"
|
|
::= { traps1 202 }
|
|
|
|
probeMod1err2Trap_1 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
probeMod1err2_1
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Module 1 probe 2 alarm"
|
|
::= { traps1 203 }
|
|
|
|
probeMod1err3Trap_1 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
probeMod1err3_1
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Module 1 probe 3 alarm"
|
|
::= { traps1 204 }
|
|
|
|
probeMod1err4Trap_1 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
probeMod1err4_1
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Module 1 probe 4 alarm"
|
|
::= { traps1 205 }
|
|
|
|
probeMod1err5Trap_1 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
probeMod1err5_1
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Module 1 probe 5 alarm"
|
|
::= { traps1 206 }
|
|
|
|
probeMod1err6Trap_1 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
probeMod1err6_1
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Module 1 probe 6 alarm"
|
|
::= { traps1 207 }
|
|
|
|
probeMod2COMTrap_1 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
probeMod2COM_1
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Module 2 communication"
|
|
::= { traps1 208 }
|
|
|
|
probeMod2err1Trap_1 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
probeMod2err1_1
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Module 2 probe 1 alarm"
|
|
::= { traps1 209 }
|
|
|
|
probeMod2err2Trap_1 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
probeMod2err2_1
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Module 2 probe 2 alarm"
|
|
::= { traps1 210 }
|
|
|
|
probeMod2err3Trap_1 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
probeMod2err3_1
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Module 2 probe 3 alarm"
|
|
::= { traps1 211 }
|
|
|
|
probeMod2err4Trap_1 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
probeMod2err4_1
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Module 2 probe 4 alarm"
|
|
::= { traps1 212 }
|
|
|
|
probeMod2err5Trap_1 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
probeMod2err5_1
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Module 2 probe 5 alarm"
|
|
::= { traps1 213 }
|
|
|
|
probeMod2err6Trap_1 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
probeMod2err6_1
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Module 2 probe 6 alarm"
|
|
::= { traps1 214 }
|
|
|
|
probeMod3COMTrap_1 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
probeMod3COM_1
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Module 3 communication"
|
|
::= { traps1 215 }
|
|
|
|
probeMod3err1Trap_1 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
probeMod3err1_1
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Module 3 probe 1 alarm"
|
|
::= { traps1 216 }
|
|
|
|
probeMod3err2Trap_1 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
probeMod3err2_1
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Module 3 probe 2 alarm"
|
|
::= { traps1 217 }
|
|
|
|
probeMod3err3Trap_1 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
probeMod3err3_1
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Module 3 probe 3 alarm"
|
|
::= { traps1 218 }
|
|
|
|
probeMod3err4Trap_1 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
probeMod3err4_1
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Module 3 probe 4 alarm"
|
|
::= { traps1 219 }
|
|
|
|
probeMod3err5Trap_1 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
probeMod3err5_1
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Module 3 probe 5 alarm"
|
|
::= { traps1 220 }
|
|
|
|
probeMod3err6Trap_1 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
probeMod3err6_1
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Module 3 probe 6 alarm"
|
|
::= { traps1 221 }
|
|
|
|
binaryObjects1 OBJECT IDENTIFIER ::= { node1 1 }
|
|
|
|
damperStatusDI_1 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Motorised damper status"
|
|
::= { binaryObjects1 1 }
|
|
|
|
dirtyFilterDI_1 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Dirty filter alarm"
|
|
::= { binaryObjects1 2 }
|
|
|
|
remoteOffDI_1 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Remote OFF status"
|
|
::= { binaryObjects1 3 }
|
|
|
|
elHeaterAlarmDI_1 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Heater thermostat alarm"
|
|
::= { binaryObjects1 4 }
|
|
|
|
condPumpAlarmDI_1 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Condensate pump alarm"
|
|
::= { binaryObjects1 5 }
|
|
|
|
configurableDI1_1 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Configurable DI 1"
|
|
::= { binaryObjects1 6 }
|
|
|
|
configurableDI2_1 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Configurable DI 2"
|
|
::= { binaryObjects1 7 }
|
|
|
|
configurableDI3_1 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Configurable DI 3"
|
|
::= { binaryObjects1 8 }
|
|
|
|
configurableDI4_1 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Configurable DI 4"
|
|
::= { binaryObjects1 9 }
|
|
|
|
configurableDI5_1 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Configurable DI 5"
|
|
::= { binaryObjects1 10 }
|
|
|
|
c1ThermAlarmDI_1 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Comp1 thermal alarm"
|
|
::= { binaryObjects1 11 }
|
|
|
|
c1HPAlarmDI_1 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Comp1 high pressure alarm"
|
|
::= { binaryObjects1 12 }
|
|
|
|
c1LPAlarmDI_1 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Comp1 low pressure alarm"
|
|
::= { binaryObjects1 13 }
|
|
|
|
c2ThermAlarmDI_1 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Comp2 thermal alarm"
|
|
::= { binaryObjects1 14 }
|
|
|
|
c2HPAlarmDI_1 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Comp2 high pressure alarm"
|
|
::= { binaryObjects1 15 }
|
|
|
|
c2LPAlarmDI_1 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Comp2 low pressure alarm"
|
|
::= { binaryObjects1 16 }
|
|
|
|
fansDO_1 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Fan control"
|
|
::= { binaryObjects1 17 }
|
|
|
|
damperDO_1 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Motorised dampers control"
|
|
::= { binaryObjects1 18 }
|
|
|
|
configurableDO1_1 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Configurable DO 1"
|
|
::= { binaryObjects1 19 }
|
|
|
|
configurableDO2_1 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Configurable DO 2"
|
|
::= { binaryObjects1 20 }
|
|
|
|
configurableDO3_1 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Configurable DO 3"
|
|
::= { binaryObjects1 21 }
|
|
|
|
configurableDO4_1 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Configurable DO 4"
|
|
::= { binaryObjects1 22 }
|
|
|
|
configurableDO5_1 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Configurable DO 5"
|
|
::= { binaryObjects1 23 }
|
|
|
|
eHeaterStage1DO_1 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Electric heat stage 1"
|
|
::= { binaryObjects1 24 }
|
|
|
|
eHeaterStage2DO_1 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Electric heat stage 2"
|
|
::= { binaryObjects1 25 }
|
|
|
|
compressor1DO_1 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Compressor 1 control"
|
|
::= { binaryObjects1 26 }
|
|
|
|
compressor2DO_1 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Compressor 2 control"
|
|
::= { binaryObjects1 27 }
|
|
|
|
humPowerDO_1 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Humidifier control"
|
|
::= { binaryObjects1 28 }
|
|
|
|
humDrainValveDO_1 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Humidifier Discharge"
|
|
::= { binaryObjects1 29 }
|
|
|
|
humFillValveDO_1 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Humidifier Charging"
|
|
::= { binaryObjects1 30 }
|
|
|
|
humWaterLevel_1 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Humidifier high water"
|
|
::= { binaryObjects1 31 }
|
|
|
|
supervOFF_1 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "ON/OFF from supervisor"
|
|
::= { binaryObjects1 32 }
|
|
|
|
enableHumid_1 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Humidification enabling"
|
|
::= { binaryObjects1 33 }
|
|
|
|
humManualDrain_1 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Manual draining"
|
|
::= { binaryObjects1 34 }
|
|
|
|
humCylWashing_1 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Cylinder washing"
|
|
::= { binaryObjects1 35 }
|
|
|
|
tSManExchange_1 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "TS manual exchange"
|
|
::= { binaryObjects1 36 }
|
|
|
|
tSTempExchEnab_1 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Enable TS room temp. exc."
|
|
::= { binaryObjects1 37 }
|
|
|
|
damperAlRes_1 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Reset damper status AL"
|
|
::= { binaryObjects1 38 }
|
|
|
|
fireSmokeAlRes_1 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Reset smoke/fire AL"
|
|
::= { binaryObjects1 39 }
|
|
|
|
genSerAlRes_1 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Reset generic serious AL"
|
|
::= { binaryObjects1 40 }
|
|
|
|
fansGenAlRes_1 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Reset supply fan AL"
|
|
::= { binaryObjects1 41 }
|
|
|
|
f1InvAlRes_1 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Reset fan 1 alarm"
|
|
::= { binaryObjects1 42 }
|
|
|
|
f2InvAlRes_1 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Reset fan 2 alarm"
|
|
::= { binaryObjects1 43 }
|
|
|
|
f3InvAlRes_1 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Reset fan 3 alarm"
|
|
::= { binaryObjects1 44 }
|
|
|
|
f4InvAlRes_1 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Reset fan 4 alarm"
|
|
::= { binaryObjects1 45 }
|
|
|
|
f5InvAlRes_1 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Reset fan 5 alarm"
|
|
::= { binaryObjects1 46 }
|
|
|
|
f6InvAlRes_1 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Reset fan 6 alarm"
|
|
::= { binaryObjects1 47 }
|
|
|
|
f7InvAlRes_1 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Reset fan 7 alarm"
|
|
::= { binaryObjects1 48 }
|
|
|
|
f8InvAlRes_1 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Reset fan 8 alarm"
|
|
::= { binaryObjects1 49 }
|
|
|
|
f9InvAlRes_1 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Reset fan 9 alarm"
|
|
::= { binaryObjects1 50 }
|
|
|
|
f10InvAlRes_1 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Reset fan 10 alarm"
|
|
::= { binaryObjects1 51 }
|
|
|
|
invCompAlRes_1 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Reset inverter alarm"
|
|
::= { binaryObjects1 52 }
|
|
|
|
c1ThermAlRes_1 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Reset C1 thermal AL"
|
|
::= { binaryObjects1 53 }
|
|
|
|
c1HighPresAlRes_1 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Reset C1 high pressure AL"
|
|
::= { binaryObjects1 54 }
|
|
|
|
c1LowPresAlRes_1 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Reset C1 low pressure AL"
|
|
::= { binaryObjects1 55 }
|
|
|
|
c1HighDisTAlRes_1 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Reset C1 high disch. AL"
|
|
::= { binaryObjects1 56 }
|
|
|
|
c1LCompRatAlRes_1 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Reset C1 low compres. AL"
|
|
::= { binaryObjects1 57 }
|
|
|
|
condenser1AlRes_1 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Reset condenser 1 AL"
|
|
::= { binaryObjects1 58 }
|
|
|
|
eEV1AlRes_1 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Reset EEV1 alarm"
|
|
::= { binaryObjects1 59 }
|
|
|
|
c2ThermAlRes_1 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Reset C2 thermal AL"
|
|
::= { binaryObjects1 60 }
|
|
|
|
c2HighPresAlRes_1 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Reset C2 high pressure AL"
|
|
::= { binaryObjects1 61 }
|
|
|
|
c2LowPresAlRes_1 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Reset C2 low pressure AL"
|
|
::= { binaryObjects1 62 }
|
|
|
|
c2HighDisTAlRes_1 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Reset C2 high disch. AL"
|
|
::= { binaryObjects1 63 }
|
|
|
|
c2LComRatAlRes_1 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Reset C2 low compres. AL"
|
|
::= { binaryObjects1 64 }
|
|
|
|
condenser2AlRes_1 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Reset condenser 2 AL"
|
|
::= { binaryObjects1 65 }
|
|
|
|
eEV2AlRes_1 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Reset EEV2 alarm"
|
|
::= { binaryObjects1 66 }
|
|
|
|
intHumidifAlRes_1 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Reset int. humidifier AL"
|
|
::= { binaryObjects1 67 }
|
|
|
|
watPresAlRes_1 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Reset water presence AL"
|
|
::= { binaryObjects1 68 }
|
|
|
|
drainPumpAlRes_1 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Reset drain pump AL"
|
|
::= { binaryObjects1 69 }
|
|
|
|
elHeatAlRes_1 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Reset electric heater AL"
|
|
::= { binaryObjects1 70 }
|
|
|
|
filterAlRes_1 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Reset dirty filter AL"
|
|
::= { binaryObjects1 71 }
|
|
|
|
dryCoolerAlRes_1 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Reset dry cooler AL"
|
|
::= { binaryObjects1 72 }
|
|
|
|
extHumidifAlRes_1 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Reset ext. humidifier AL"
|
|
::= { binaryObjects1 73 }
|
|
|
|
waterPumpAlRes_1 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Reset water pump AL"
|
|
::= { binaryObjects1 74 }
|
|
|
|
condUnitGAlRes_1 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Reset motocondenser AL"
|
|
::= { binaryObjects1 75 }
|
|
|
|
gasLeakAlRes_1 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Reset gas leak AL"
|
|
::= { binaryObjects1 76 }
|
|
|
|
powerSupAlRes_1 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Reset power fault AL"
|
|
::= { binaryObjects1 77 }
|
|
|
|
genSoftAlRes_1 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Reset generic soft AL"
|
|
::= { binaryObjects1 78 }
|
|
|
|
scalarsObjects1 OBJECT IDENTIFIER ::= { node1 2 }
|
|
|
|
confDI1Combo_1 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Configurable DI1 meaning"
|
|
::= { scalarsObjects1 1 }
|
|
|
|
confDI2Combo_1 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Configurable DI2 meaning"
|
|
::= { scalarsObjects1 2 }
|
|
|
|
confDI3Combo_1 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Configurable DI3 meaning"
|
|
::= { scalarsObjects1 3 }
|
|
|
|
confDI4Combo_1 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Configurable DI4 meaning"
|
|
::= { scalarsObjects1 4 }
|
|
|
|
confDI5Combo_1 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Configurable DI5 meaning"
|
|
::= { scalarsObjects1 5 }
|
|
|
|
confDO1Combo_1 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Configurable DO1 meaning"
|
|
::= { scalarsObjects1 6 }
|
|
|
|
confDO2Combo_1 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Configurable DO2 meaning"
|
|
::= { scalarsObjects1 7 }
|
|
|
|
confDO3Combo_1 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Configurable DO3 meaning"
|
|
::= { scalarsObjects1 8 }
|
|
|
|
confDO4Combo_1 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Configurable DO4 meaning"
|
|
::= { scalarsObjects1 9 }
|
|
|
|
confDO5Combo_1 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Configurable DO5 meaning"
|
|
::= { scalarsObjects1 10 }
|
|
|
|
returnTemp_1 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Return temperature"
|
|
::= { scalarsObjects1 11 }
|
|
|
|
returnTAvg_1 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Return temperature (AVG)"
|
|
::= { scalarsObjects1 12 }
|
|
|
|
supplyTemp_1 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Supply temperature"
|
|
::= { scalarsObjects1 13 }
|
|
|
|
supplyTAvg_1 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Supply temperature (AVG)"
|
|
::= { scalarsObjects1 14 }
|
|
|
|
tempDelta_1 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Temperature delta"
|
|
::= { scalarsObjects1 15 }
|
|
|
|
returnHumidity_1 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Return humidity"
|
|
::= { scalarsObjects1 16 }
|
|
|
|
returnHumAvg_1 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Return humidity (AVG)"
|
|
::= { scalarsObjects1 17 }
|
|
|
|
supplyHumidity_1 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Supply humidity"
|
|
::= { scalarsObjects1 18 }
|
|
|
|
supplyHumAvg_1 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Supply humidity (AVG)"
|
|
::= { scalarsObjects1 19 }
|
|
|
|
airFlow_1 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Air flow"
|
|
::= { scalarsObjects1 20 }
|
|
|
|
airPressure_1 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Air pressure"
|
|
::= { scalarsObjects1 22 }
|
|
|
|
airPressureAvg_1 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Air pressure (Average)"
|
|
::= { scalarsObjects1 23 }
|
|
|
|
netMod1Combo1_1 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Module 1 - Probe 1 status"
|
|
::= { scalarsObjects1 24 }
|
|
|
|
netMod1Probe1_1 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Module 1 - Probe 1 value"
|
|
::= { scalarsObjects1 25 }
|
|
|
|
netMod1Combo2_1 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Module 1 - Probe 2 status"
|
|
::= { scalarsObjects1 26 }
|
|
|
|
netMod1Probe2_1 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Module 1 - Probe 2 value"
|
|
::= { scalarsObjects1 27 }
|
|
|
|
netMod1Combo3_1 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Module 1 - Probe 3 status"
|
|
::= { scalarsObjects1 28 }
|
|
|
|
netMod1Probe3_1 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Module 1 - Probe 3 value"
|
|
::= { scalarsObjects1 29 }
|
|
|
|
netMod1Combo4_1 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Module 1 - Probe 4 status"
|
|
::= { scalarsObjects1 30 }
|
|
|
|
netMod1Probe4_1 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Module 1 - Probe 4 value"
|
|
::= { scalarsObjects1 31 }
|
|
|
|
netMod1Combo5_1 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Module 1 - Probe 5 status"
|
|
::= { scalarsObjects1 32 }
|
|
|
|
netMod1Probe5_1 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Module 1 - Probe 5 value"
|
|
::= { scalarsObjects1 33 }
|
|
|
|
netMod1Combo6_1 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Module 1 - Probe 6 status"
|
|
::= { scalarsObjects1 34 }
|
|
|
|
netMod1Probe6_1 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Module 1 - Probe 6 value"
|
|
::= { scalarsObjects1 35 }
|
|
|
|
netMod2Combo1_1 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Module 2 - Probe 1 status"
|
|
::= { scalarsObjects1 36 }
|
|
|
|
netMod2Probe1_1 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Module 2 - Probe 1 value"
|
|
::= { scalarsObjects1 37 }
|
|
|
|
netMod2Combo2_1 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Module 2 - Probe 2 status"
|
|
::= { scalarsObjects1 38 }
|
|
|
|
netMod2Probe2_1 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Module 2 - Probe 2 value"
|
|
::= { scalarsObjects1 39 }
|
|
|
|
netMod2Combo3_1 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Module 2 - Probe 3 status"
|
|
::= { scalarsObjects1 40 }
|
|
|
|
netMod2Probe3_1 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Module 2 - Probe 3 value"
|
|
::= { scalarsObjects1 41 }
|
|
|
|
netMod2Combo4_1 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Module 2 - Probe 4 status"
|
|
::= { scalarsObjects1 42 }
|
|
|
|
netMod2Probe4_1 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Module 2 - Probe 4 value"
|
|
::= { scalarsObjects1 43 }
|
|
|
|
netMod2Combo5_1 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Module 2 - Probe 5 status"
|
|
::= { scalarsObjects1 44 }
|
|
|
|
netMod2Probe5_1 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Module 2 - Probe 5 value"
|
|
::= { scalarsObjects1 45 }
|
|
|
|
netMod2Combo6_1 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Module 2 - Probe 6 status"
|
|
::= { scalarsObjects1 46 }
|
|
|
|
netMod2Probe6_1 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Module 2 - Probe 6 value"
|
|
::= { scalarsObjects1 47 }
|
|
|
|
netMod3Combo1_1 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Module 3 - Probe 1 status"
|
|
::= { scalarsObjects1 48 }
|
|
|
|
netMod3Probe1_1 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Module 3 - Probe 1 value"
|
|
::= { scalarsObjects1 49 }
|
|
|
|
netMod3Combo2_1 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Module 3 - Probe 2 status"
|
|
::= { scalarsObjects1 50 }
|
|
|
|
netMod3Probe2_1 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Module 3 - Probe 2 value"
|
|
::= { scalarsObjects1 51 }
|
|
|
|
netMod3Combo3_1 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Module 3 - Probe 3 status"
|
|
::= { scalarsObjects1 52 }
|
|
|
|
netMod3Probe3_1 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Module 3 - Probe 3 value"
|
|
::= { scalarsObjects1 53 }
|
|
|
|
netMod3Combo4_1 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Module 3 - Probe 4 status"
|
|
::= { scalarsObjects1 54 }
|
|
|
|
netMod3Probe4_1 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Module 3 - Probe 4 value"
|
|
::= { scalarsObjects1 55 }
|
|
|
|
netMod3Combo5_1 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Module 3 - Probe 5 status"
|
|
::= { scalarsObjects1 56 }
|
|
|
|
netMod3Probe5_1 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Module 3 - Probe 5 value"
|
|
::= { scalarsObjects1 57 }
|
|
|
|
netMod3Combo6_1 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Module 3 - Probe 6 status"
|
|
::= { scalarsObjects1 58 }
|
|
|
|
netMod3Probe6_1 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Module 3 - Probe 6 value"
|
|
::= { scalarsObjects1 59 }
|
|
|
|
avgModTemp_1 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Modules temperatures AVG"
|
|
::= { scalarsObjects1 60 }
|
|
|
|
avgModHumi_1 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Modules humidity AVG"
|
|
::= { scalarsObjects1 61 }
|
|
|
|
avgModPress_1 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Modules pressure AVG"
|
|
::= { scalarsObjects1 62 }
|
|
|
|
dryCoolerAO_1 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Supply Fan/Dry cooler"
|
|
::= { scalarsObjects1 63 }
|
|
|
|
coolingAO_1 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Cooling valve/FC/Inverter"
|
|
::= { scalarsObjects1 64 }
|
|
|
|
heatingAO_1 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Heating valve/Heater"
|
|
::= { scalarsObjects1 65 }
|
|
|
|
twoSources2AO_1 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "TS cooling valve 2"
|
|
::= { scalarsObjects1 66 }
|
|
|
|
condenser1AO_1 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Condenser 1"
|
|
::= { scalarsObjects1 67 }
|
|
|
|
cond2HumidifAO_1 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Condenser 2/Humidifier"
|
|
::= { scalarsObjects1 68 }
|
|
|
|
unitStatus_1 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Unit status"
|
|
::= { scalarsObjects1 69 }
|
|
|
|
fanSpeed_1 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Fan speed"
|
|
::= { scalarsObjects1 70 }
|
|
|
|
fan1Actspeed_1 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Fan 1 speed"
|
|
::= { scalarsObjects1 71 }
|
|
|
|
fan1ActRPM_1 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Fan 1 speed RPM"
|
|
::= { scalarsObjects1 72 }
|
|
|
|
fan1Cur_1 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Fan 1 current"
|
|
::= { scalarsObjects1 73 }
|
|
|
|
fan1Power_1 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Fan 1 power"
|
|
::= { scalarsObjects1 74 }
|
|
|
|
fan2Actspeed_1 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Fan 2 speed"
|
|
::= { scalarsObjects1 75 }
|
|
|
|
fan2ActRPM_1 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Fan 2 speed RPM"
|
|
::= { scalarsObjects1 76 }
|
|
|
|
fan2Cur_1 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Fan 2 current"
|
|
::= { scalarsObjects1 77 }
|
|
|
|
fan2Power_1 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Fan 2 power"
|
|
::= { scalarsObjects1 78 }
|
|
|
|
fan3Actspeed_1 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Fan 3 speed"
|
|
::= { scalarsObjects1 79 }
|
|
|
|
fan3ActRPM_1 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Fan 3 speed RPM"
|
|
::= { scalarsObjects1 80 }
|
|
|
|
fan3Cur_1 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Fan 3 current"
|
|
::= { scalarsObjects1 81 }
|
|
|
|
fan3Power_1 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Fan 3 power"
|
|
::= { scalarsObjects1 82 }
|
|
|
|
fan4Actspeed_1 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Fan 4 speed"
|
|
::= { scalarsObjects1 83 }
|
|
|
|
fan4ActRPM_1 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Fan 4 speed RPM"
|
|
::= { scalarsObjects1 84 }
|
|
|
|
fan4Cur_1 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Fan 4 current"
|
|
::= { scalarsObjects1 85 }
|
|
|
|
fan4Power_1 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Fan 4 power"
|
|
::= { scalarsObjects1 86 }
|
|
|
|
fan5Actspeed_1 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Fan 5 speed"
|
|
::= { scalarsObjects1 87 }
|
|
|
|
fan5ActRPM_1 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Fan 5 speed RPM"
|
|
::= { scalarsObjects1 88 }
|
|
|
|
fan5Cur_1 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Fan 5 current"
|
|
::= { scalarsObjects1 89 }
|
|
|
|
fan5Power_1 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Fan 5 power"
|
|
::= { scalarsObjects1 90 }
|
|
|
|
fan6Actspeed_1 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Fan 6 speed"
|
|
::= { scalarsObjects1 91 }
|
|
|
|
fan6ActRPM_1 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Fan 6 speed RPM"
|
|
::= { scalarsObjects1 92 }
|
|
|
|
fan6Cur_1 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Fan 6 current"
|
|
::= { scalarsObjects1 93 }
|
|
|
|
fan6Power_1 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Fan 6 power"
|
|
::= { scalarsObjects1 94 }
|
|
|
|
fan7Actspeed_1 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Fan 7 speed"
|
|
::= { scalarsObjects1 95 }
|
|
|
|
fan7ActRPM_1 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Fan 7 speed RPM"
|
|
::= { scalarsObjects1 96 }
|
|
|
|
fan7Cur_1 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Fan 7 current"
|
|
::= { scalarsObjects1 97 }
|
|
|
|
fan7Power_1 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Fan 7 power"
|
|
::= { scalarsObjects1 98 }
|
|
|
|
fan8Actspeed_1 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Fan 8 speed"
|
|
::= { scalarsObjects1 99 }
|
|
|
|
fan8ActRPM_1 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Fan 8 speed RPM"
|
|
::= { scalarsObjects1 100 }
|
|
|
|
fan8Cur_1 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Fan 8 current"
|
|
::= { scalarsObjects1 101 }
|
|
|
|
fan8Power_1 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Fan 8 power"
|
|
::= { scalarsObjects1 102 }
|
|
|
|
fan9Actspeed_1 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Fan 9 speed"
|
|
::= { scalarsObjects1 103 }
|
|
|
|
fan9ActRPM_1 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Fan 9 speed RPM"
|
|
::= { scalarsObjects1 104 }
|
|
|
|
fan9Cur_1 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Fan 9 current"
|
|
::= { scalarsObjects1 105 }
|
|
|
|
fan9Power_1 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Fan 9 power"
|
|
::= { scalarsObjects1 106 }
|
|
|
|
fan10Actspeed_1 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Fan 10 speed"
|
|
::= { scalarsObjects1 107 }
|
|
|
|
fan10ActRPM_1 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Fan 10 speed RPM"
|
|
::= { scalarsObjects1 108 }
|
|
|
|
fan10Cur_1 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Fan 10 current"
|
|
::= { scalarsObjects1 109 }
|
|
|
|
fan10Power_1 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Fan 10 power"
|
|
::= { scalarsObjects1 110 }
|
|
|
|
diffFilterPres_1 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Dirty filter pressure"
|
|
::= { scalarsObjects1 111 }
|
|
|
|
coolingRequest_1 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Cooling request"
|
|
::= { scalarsObjects1 112 }
|
|
|
|
heatingRequest_1 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Heating request"
|
|
::= { scalarsObjects1 113 }
|
|
|
|
dehumidRequest_1 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Dehumidification request"
|
|
::= { scalarsObjects1 114 }
|
|
|
|
humidifRequest_1 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Humidification request"
|
|
::= { scalarsObjects1 115 }
|
|
|
|
tempFcTs_1 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "FC/TS temperature"
|
|
::= { scalarsObjects1 116 }
|
|
|
|
fCTSStatus_1 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "FC/TS status"
|
|
::= { scalarsObjects1 117 }
|
|
|
|
fCRequest_1 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Free cooling request"
|
|
::= { scalarsObjects1 118 }
|
|
|
|
activeComp_1 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Active compressor"
|
|
::= { scalarsObjects1 119 }
|
|
|
|
comp1Sts_1 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Compressor 1 Status"
|
|
::= { scalarsObjects1 120 }
|
|
|
|
comp2Sts_1 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Compressor 2 Status"
|
|
::= { scalarsObjects1 121 }
|
|
|
|
invComprReq_1 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Inverter compressor request"
|
|
::= { scalarsObjects1 122 }
|
|
|
|
invCompHz_1 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Inverter frequency"
|
|
::= { scalarsObjects1 123 }
|
|
|
|
invCompPower_1 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Inverter power input"
|
|
::= { scalarsObjects1 124 }
|
|
|
|
invCompCurrent_1 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Inverter absorbed current"
|
|
::= { scalarsObjects1 125 }
|
|
|
|
c1EvapPres_1 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "C1 evaporation pressure"
|
|
::= { scalarsObjects1 126 }
|
|
|
|
c1EvapTemp_1 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "C1 evaporation temperature"
|
|
::= { scalarsObjects1 127 }
|
|
|
|
c1SuctionTemp_1 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "C1 suction temperature"
|
|
::= { scalarsObjects1 128 }
|
|
|
|
c1Superheat_1 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "C1 super-heating"
|
|
::= { scalarsObjects1 129 }
|
|
|
|
c1CompRatio_1 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "C1 compression ratio"
|
|
::= { scalarsObjects1 130 }
|
|
|
|
c1DischTemp_1 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "C1 discharge temperature"
|
|
::= { scalarsObjects1 131 }
|
|
|
|
c1CondPress_1 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "C1 condensation pressure"
|
|
::= { scalarsObjects1 132 }
|
|
|
|
c1CondTemp_1 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "C1 condensation temperature"
|
|
::= { scalarsObjects1 133 }
|
|
|
|
c1Desuperheat_1 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "C1 de-superheating"
|
|
::= { scalarsObjects1 134 }
|
|
|
|
c1LiquidTemp_1 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "C1 liquid temperature"
|
|
::= { scalarsObjects1 135 }
|
|
|
|
c1Subcooling_1 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "C1 sub-cooling"
|
|
::= { scalarsObjects1 136 }
|
|
|
|
eEV1SHSet_1 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "EEV1 super-heating set-point"
|
|
::= { scalarsObjects1 137 }
|
|
|
|
eEV1Position_1 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "EEV1 position"
|
|
::= { scalarsObjects1 138 }
|
|
|
|
eEV1Status_1 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "EEV1 working status"
|
|
::= { scalarsObjects1 139 }
|
|
|
|
cond1ActualSet_1 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Condenser 1 current set"
|
|
::= { scalarsObjects1 140 }
|
|
|
|
cond1Req_1 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Condenser 1 request"
|
|
::= { scalarsObjects1 141 }
|
|
|
|
c2EvapPres_1 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "C2 evaporation pressure"
|
|
::= { scalarsObjects1 142 }
|
|
|
|
c2EvapTemp_1 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "C2 evaporation temperature"
|
|
::= { scalarsObjects1 143 }
|
|
|
|
c2SuctionTemp_1 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "C2 suction temperature"
|
|
::= { scalarsObjects1 144 }
|
|
|
|
c2Superheat_1 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "C2 super-heating"
|
|
::= { scalarsObjects1 145 }
|
|
|
|
c2CompRatio_1 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "C2 compression ratio"
|
|
::= { scalarsObjects1 146 }
|
|
|
|
c2DischTemp_1 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "C2 discharge temperature"
|
|
::= { scalarsObjects1 147 }
|
|
|
|
c2CondPress_1 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "C2 condensation pressure"
|
|
::= { scalarsObjects1 148 }
|
|
|
|
c2CondTemp_1 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "C2 condensation temperature"
|
|
::= { scalarsObjects1 149 }
|
|
|
|
c2Desuperheat_1 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "C2 de-superheating"
|
|
::= { scalarsObjects1 150 }
|
|
|
|
c2LiquidTemp_1 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "C2 liquid temperature"
|
|
::= { scalarsObjects1 151 }
|
|
|
|
c2Subcooling_1 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "C2 sub-cooling"
|
|
::= { scalarsObjects1 152 }
|
|
|
|
eEV2SHSet_1 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "EEV2 superheat set-point"
|
|
::= { scalarsObjects1 153 }
|
|
|
|
eEV2Position_1 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "EEV2 position"
|
|
::= { scalarsObjects1 154 }
|
|
|
|
eEV2Status_1 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "EEV2 working status"
|
|
::= { scalarsObjects1 155 }
|
|
|
|
cond2ActualSet_1 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Condenser 2 current set"
|
|
::= { scalarsObjects1 156 }
|
|
|
|
cond2Req_1 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Condenser 2 request"
|
|
::= { scalarsObjects1 157 }
|
|
|
|
waterINTemp1_1 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Water IN temperature 1"
|
|
::= { scalarsObjects1 158 }
|
|
|
|
waterOUTTemp1_1 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Water OUT temperature 1"
|
|
::= { scalarsObjects1 159 }
|
|
|
|
waterDT1_1 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Water temperature delta 1"
|
|
::= { scalarsObjects1 160 }
|
|
|
|
waterFlow1_1 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Water flow rate 1"
|
|
::= { scalarsObjects1 161 }
|
|
|
|
actWatFlowSet1_1 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Actual water flow set 1"
|
|
::= { scalarsObjects1 162 }
|
|
|
|
waterCoolCap1_1 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Water cooling capacity 1"
|
|
::= { scalarsObjects1 163 }
|
|
|
|
eER1_1 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "EER 1"
|
|
::= { scalarsObjects1 164 }
|
|
|
|
valve1Position_1 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Water valve 1 position"
|
|
::= { scalarsObjects1 165 }
|
|
|
|
waterINTemp2_1 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Water IN temperature 2"
|
|
::= { scalarsObjects1 166 }
|
|
|
|
waterOUTTemp2_1 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Water OUT temperature 2"
|
|
::= { scalarsObjects1 167 }
|
|
|
|
waterDT2_1 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Water temperature delta 2"
|
|
::= { scalarsObjects1 168 }
|
|
|
|
waterFlow2_1 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Water flow rate 2"
|
|
::= { scalarsObjects1 169 }
|
|
|
|
actWatFlowSet2_1 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Actual water flow set 2"
|
|
::= { scalarsObjects1 170 }
|
|
|
|
waterCoolCap2_1 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Water cooling capacity 2"
|
|
::= { scalarsObjects1 171 }
|
|
|
|
eER2_1 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "EER 2"
|
|
::= { scalarsObjects1 172 }
|
|
|
|
valve2Position_1 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Water valve 2 position"
|
|
::= { scalarsObjects1 173 }
|
|
|
|
humSteamProd_1 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Current steam production"
|
|
::= { scalarsObjects1 174 }
|
|
|
|
humWaterConduct_1 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Humidifier conductivity"
|
|
::= { scalarsObjects1 175 }
|
|
|
|
humCurrent_1 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Humidifier abs. Current"
|
|
::= { scalarsObjects1 176 }
|
|
|
|
humWorkingMode_1 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Humidifier operating mode"
|
|
::= { scalarsObjects1 177 }
|
|
|
|
humWorkStatus_1 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Humidifier operating status"
|
|
::= { scalarsObjects1 178 }
|
|
|
|
heaterReq_1 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Electric heater request"
|
|
::= { scalarsObjects1 179 }
|
|
|
|
heaterActiveStg_1 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Number of active stages"
|
|
::= { scalarsObjects1 180 }
|
|
|
|
elHeaterPower_1 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Electric heater power"
|
|
::= { scalarsObjects1 181 }
|
|
|
|
heatValveReq_1 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Hot water valve request"
|
|
::= { scalarsObjects1 182 }
|
|
|
|
dryCoolerActSet_1 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Current dry cooler set"
|
|
::= { scalarsObjects1 183 }
|
|
|
|
dryCoolerReq_1 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Dry cooler request"
|
|
::= { scalarsObjects1 184 }
|
|
|
|
unitWH_1 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Unit working hours"
|
|
::= { scalarsObjects1 185 }
|
|
|
|
c1WH_1 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Compressor1 working hours"
|
|
::= { scalarsObjects1 186 }
|
|
|
|
c1Startup_1 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Compressor 1 startups"
|
|
::= { scalarsObjects1 187 }
|
|
|
|
c2WH_1 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Compressor2 working hours"
|
|
::= { scalarsObjects1 188 }
|
|
|
|
c2Startup_1 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Compressor 2 startups"
|
|
::= { scalarsObjects1 189 }
|
|
|
|
coolValveWH_1 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Cooling working hours"
|
|
::= { scalarsObjects1 190 }
|
|
|
|
heatingWH_1 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Heating working hours"
|
|
::= { scalarsObjects1 191 }
|
|
|
|
humidifWH_1 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Humidifier working hours"
|
|
::= { scalarsObjects1 192 }
|
|
|
|
freeCoolWH_1 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "FC working hours"
|
|
::= { scalarsObjects1 193 }
|
|
|
|
dryCoolerWH_1 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Dry cooler working hours"
|
|
::= { scalarsObjects1 194 }
|
|
|
|
cond1WH_1 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Condenser1 working hours"
|
|
::= { scalarsObjects1 195 }
|
|
|
|
cond2WH_1 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Condenser2 working hours"
|
|
::= { scalarsObjects1 196 }
|
|
|
|
tempSetpoint_1 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Temperature set-point"
|
|
::= { scalarsObjects1 197 }
|
|
|
|
humSetpoint_1 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Humidity set-point"
|
|
::= { scalarsObjects1 198 }
|
|
|
|
airFlowSetpoint_1 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Air flow set-point"
|
|
::= { scalarsObjects1 199 }
|
|
|
|
airPresSetpoint_1 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Air pressure set-point"
|
|
::= { scalarsObjects1 200 }
|
|
|
|
airDTSetpoint_1 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Air temperature delta set"
|
|
::= { scalarsObjects1 201 }
|
|
|
|
tempControlSel_1 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Regulation sensor"
|
|
::= { scalarsObjects1 202 }
|
|
|
|
tempControlType_1 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Regulation type"
|
|
::= { scalarsObjects1 203 }
|
|
|
|
tPropBand_1 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Proportional Band"
|
|
::= { scalarsObjects1 204 }
|
|
|
|
tIntegralTime_1 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Integration time"
|
|
::= { scalarsObjects1 205 }
|
|
|
|
tDerivativeTime_1 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Derivative time"
|
|
::= { scalarsObjects1 206 }
|
|
|
|
highTAlOffset_1 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "High temperature offset"
|
|
::= { scalarsObjects1 207 }
|
|
|
|
lowTAlOffset_1 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Low temperature offset"
|
|
::= { scalarsObjects1 208 }
|
|
|
|
highLimitTThr_1 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "High limit temp. thresh."
|
|
::= { scalarsObjects1 209 }
|
|
|
|
highLimitTMng_1 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "High limit temp. managem."
|
|
::= { scalarsObjects1 210 }
|
|
|
|
lowLimitTThr_1 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Low limit temp.thresh."
|
|
::= { scalarsObjects1 211 }
|
|
|
|
lowLimitTMng_1 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Low limit temp. managem."
|
|
::= { scalarsObjects1 212 }
|
|
|
|
dehumPropBand_1 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Dehumid. proportion. band"
|
|
::= { scalarsObjects1 213 }
|
|
|
|
humPropBand_1 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Humid. proportion. band"
|
|
::= { scalarsObjects1 214 }
|
|
|
|
hRetHAlOffset_1 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "High humidity offset"
|
|
::= { scalarsObjects1 215 }
|
|
|
|
lRetHAlOffset_1 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Low humidity offset"
|
|
::= { scalarsObjects1 216 }
|
|
|
|
highSupHumThr_1 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "High supp. humidity thr."
|
|
::= { scalarsObjects1 217 }
|
|
|
|
lowSupHumThr_1 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Low supp. humidity thr."
|
|
::= { scalarsObjects1 218 }
|
|
|
|
fCDelta_1 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Free cooling delta"
|
|
::= { scalarsObjects1 219 }
|
|
|
|
tSWaterSet_1 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Two sources set-point"
|
|
::= { scalarsObjects1 220 }
|
|
|
|
tSWaterPropBand_1 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Two sources band"
|
|
::= { scalarsObjects1 221 }
|
|
|
|
tSAirTempSet_1 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "TS room temp. Exch. set"
|
|
::= { scalarsObjects1 222 }
|
|
|
|
condSetpoint_1 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Condensation set-point"
|
|
::= { scalarsObjects1 223 }
|
|
|
|
condPropoBand_1 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Condensation band"
|
|
::= { scalarsObjects1 224 }
|
|
|
|
condSetIncrease_1 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Condensation set increase"
|
|
::= { scalarsObjects1 225 }
|
|
|
|
maxCondSetpoint_1 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Maximum condensation set"
|
|
::= { scalarsObjects1 226 }
|
|
|
|
dryCoolerSet_1 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Dry cooler set-point"
|
|
::= { scalarsObjects1 227 }
|
|
|
|
dryCoolPropBand_1 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Dry cooler band"
|
|
::= { scalarsObjects1 228 }
|
|
|
|
dryCoolSetIncr_1 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Dry Cooler set increase"
|
|
::= { scalarsObjects1 229 }
|
|
|
|
maxDryCoolerSet_1 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Maximum dry Cooler set"
|
|
::= { scalarsObjects1 230 }
|
|
|
|
dirtyFiltSet_1 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Dirty filter set-point"
|
|
::= { scalarsObjects1 231 }
|
|
|
|
dirtyFiltDiff_1 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Dirty filter differential"
|
|
::= { scalarsObjects1 232 }
|
|
|
|
invCompAlCode1_1 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "DC Inverter alarm code 1"
|
|
::= { scalarsObjects1 233 }
|
|
|
|
invCompAlCode2_1 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "DC Inverter alarm code 2"
|
|
::= { scalarsObjects1 234 }
|
|
|
|
invCompAlCode3_1 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "DC Inverter alarm code 3"
|
|
::= { scalarsObjects1 235 }
|
|
|
|
invCompAlCode4_1 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "DC Inverter alarm code 4"
|
|
::= { scalarsObjects1 236 }
|
|
|
|
invCompAlCode5_1 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "DC Inverter alarm code 5"
|
|
::= { scalarsObjects1 237 }
|
|
|
|
alarms1 OBJECT IDENTIFIER ::= { node1 3 }
|
|
|
|
generalAl_1 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "General alarams"
|
|
::= { alarms1 1 }
|
|
|
|
notCriticAl_1 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Not critical alarms"
|
|
::= { alarms1 2 }
|
|
|
|
criticalAl_1 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Critical alarms"
|
|
::= { alarms1 3 }
|
|
|
|
fansAl_1 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Fans alarms"
|
|
::= { alarms1 4 }
|
|
|
|
compAl_1 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Compressors alarms"
|
|
::= { alarms1 5 }
|
|
|
|
tempAl_1 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Temperature alarms"
|
|
::= { alarms1 6 }
|
|
|
|
humidityAl_1 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Humidity alarms"
|
|
::= { alarms1 7 }
|
|
|
|
damperAl_1 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Damper status alarm"
|
|
::= { alarms1 8 }
|
|
|
|
fireSmokeAl_1 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Fire/Smoke alarm"
|
|
::= { alarms1 9 }
|
|
|
|
gSeriousAl_1 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Critical generic alarm"
|
|
::= { alarms1 10 }
|
|
|
|
fansGenAl_1 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "General supply fans alarm"
|
|
::= { alarms1 11 }
|
|
|
|
f1GeneralAl_1 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Fan general alarm 1"
|
|
::= { alarms1 12 }
|
|
|
|
f1PowerAl_1 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Phase failure/undervolt.1"
|
|
::= { alarms1 13 }
|
|
|
|
f1CommAl_1 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Communication 1"
|
|
::= { alarms1 14 }
|
|
|
|
f1HiTempAl_1 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Power mod overheated 1"
|
|
::= { alarms1 15 }
|
|
|
|
f1NetComAl_1 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Master/Slave com. 1"
|
|
::= { alarms1 16 }
|
|
|
|
f1InvRegAl_1 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Regulation module 1"
|
|
::= { alarms1 17 }
|
|
|
|
f1HiMotTAl_1 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Motor overheated 1"
|
|
::= { alarms1 18 }
|
|
|
|
f1HallSenAl_1 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Hall sensor error 1"
|
|
::= { alarms1 19 }
|
|
|
|
f1OverlAl_1 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Locked motor 1"
|
|
::= { alarms1 20 }
|
|
|
|
f1LowDCAl_1 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Low DC 1"
|
|
::= { alarms1 21 }
|
|
|
|
f2GeneralAl_1 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Fan general alarm 2"
|
|
::= { alarms1 22 }
|
|
|
|
f2PowerAl_1 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Phase failure/undervolt.2"
|
|
::= { alarms1 23 }
|
|
|
|
f2CommAl_1 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Communication 2"
|
|
::= { alarms1 24 }
|
|
|
|
f2HiTempAl_1 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Power mod overheated 2"
|
|
::= { alarms1 25 }
|
|
|
|
f2NetComAl_1 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Master/Slave com. 2"
|
|
::= { alarms1 26 }
|
|
|
|
f2InvRegAl_1 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Regulation module 2"
|
|
::= { alarms1 27 }
|
|
|
|
f2HiMotTAl_1 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Motor overheated 2"
|
|
::= { alarms1 28 }
|
|
|
|
f2HallSenAl_1 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Hall sensor error 2"
|
|
::= { alarms1 29 }
|
|
|
|
f2OverlAl_1 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Locked motor 2"
|
|
::= { alarms1 30 }
|
|
|
|
f2LowDCAl_1 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Low DC 2"
|
|
::= { alarms1 31 }
|
|
|
|
f3GeneralAl_1 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Fan general alarm 3"
|
|
::= { alarms1 32 }
|
|
|
|
f3PowerAl_1 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Phase failure/undervolt.3"
|
|
::= { alarms1 33 }
|
|
|
|
f3CommAl_1 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Communication 3"
|
|
::= { alarms1 34 }
|
|
|
|
f3HiTempAl_1 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Power mod overheated 3"
|
|
::= { alarms1 35 }
|
|
|
|
f3NetComAl_1 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Master/Slave com. 3"
|
|
::= { alarms1 36 }
|
|
|
|
f3InvRegAl_1 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Regulation module 3"
|
|
::= { alarms1 37 }
|
|
|
|
f3HiMotTAl_1 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Motor overheated 3"
|
|
::= { alarms1 38 }
|
|
|
|
f3HallSenAl_1 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Hall sensor error 3"
|
|
::= { alarms1 39 }
|
|
|
|
f3OverlAl_1 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Locked motor 3"
|
|
::= { alarms1 40 }
|
|
|
|
f3LowDCAl_1 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Low DC 3"
|
|
::= { alarms1 41 }
|
|
|
|
f4GeneralAl_1 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Fan general alarm 4"
|
|
::= { alarms1 42 }
|
|
|
|
f4PowerAl_1 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Phase failure/undervolt.4"
|
|
::= { alarms1 43 }
|
|
|
|
f4CommAl_1 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Communication 4"
|
|
::= { alarms1 44 }
|
|
|
|
f4HiTempAl_1 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Power mod overheated 4"
|
|
::= { alarms1 45 }
|
|
|
|
f4NetComAl_1 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Master/Slave com. 4"
|
|
::= { alarms1 46 }
|
|
|
|
f4InvRegAl_1 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Regulation module 4"
|
|
::= { alarms1 47 }
|
|
|
|
f4HiMotTAl_1 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Motor overheated 4"
|
|
::= { alarms1 48 }
|
|
|
|
f4HallSenAl_1 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Hall sensor error 4"
|
|
::= { alarms1 49 }
|
|
|
|
f4OverlAl_1 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Locked motor 4"
|
|
::= { alarms1 50 }
|
|
|
|
f4LowDCAl_1 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Low DC 4"
|
|
::= { alarms1 51 }
|
|
|
|
f5GeneralAl_1 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Fan general alarm 5"
|
|
::= { alarms1 52 }
|
|
|
|
f5PowerAl_1 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Phase failure/undervolt.5"
|
|
::= { alarms1 53 }
|
|
|
|
f5CommAl_1 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Communication 5"
|
|
::= { alarms1 54 }
|
|
|
|
f5HiTempAl_1 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Power mod overheated 5"
|
|
::= { alarms1 55 }
|
|
|
|
f5NetComAl_1 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Master/Slave com. 5"
|
|
::= { alarms1 56 }
|
|
|
|
f5InvRegAl_1 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Regulation module 5"
|
|
::= { alarms1 57 }
|
|
|
|
f5HiMotTAl_1 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Motor overheated 5"
|
|
::= { alarms1 58 }
|
|
|
|
f5HallSenAl_1 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Hall sensor error 5"
|
|
::= { alarms1 59 }
|
|
|
|
f5OverlAl_1 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Locked motor 5"
|
|
::= { alarms1 60 }
|
|
|
|
f5LowDCAl_1 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Low DC 5"
|
|
::= { alarms1 61 }
|
|
|
|
f6GeneralAl_1 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Fan general alarm 6"
|
|
::= { alarms1 62 }
|
|
|
|
f6PowerAl_1 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Phase failure/undervolt.6"
|
|
::= { alarms1 63 }
|
|
|
|
f6CommAl_1 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Communication 6"
|
|
::= { alarms1 64 }
|
|
|
|
f6HiTempAl_1 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Power mod overheated 6"
|
|
::= { alarms1 65 }
|
|
|
|
f6NetComAl_1 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Master/Slave com. 6"
|
|
::= { alarms1 66 }
|
|
|
|
f6InvRegAl_1 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Regulation module 6"
|
|
::= { alarms1 67 }
|
|
|
|
f6HiMotTAl_1 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Motor overheated 6"
|
|
::= { alarms1 68 }
|
|
|
|
f6HallSenAl_1 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Hall sensor error 6"
|
|
::= { alarms1 69 }
|
|
|
|
f6OverlAl_1 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Locked motor 6"
|
|
::= { alarms1 70 }
|
|
|
|
f6LowDCAl_1 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Low DC 6"
|
|
::= { alarms1 71 }
|
|
|
|
f7GeneralAl_1 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Fan general alarm 7"
|
|
::= { alarms1 72 }
|
|
|
|
f7PowerAl_1 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Phase failure/undervolt.7"
|
|
::= { alarms1 73 }
|
|
|
|
f7CommAl_1 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Communication 7"
|
|
::= { alarms1 74 }
|
|
|
|
f7HiTempAl_1 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Power mod overheated 7"
|
|
::= { alarms1 75 }
|
|
|
|
f7NetComAl_1 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Master/Slave com. 7"
|
|
::= { alarms1 76 }
|
|
|
|
f7InvRegAl_1 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Regulation module 7"
|
|
::= { alarms1 77 }
|
|
|
|
f7HiMotTAl_1 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Motor overheated 7"
|
|
::= { alarms1 78 }
|
|
|
|
f7HallSenAl_1 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Hall sensor error 7"
|
|
::= { alarms1 79 }
|
|
|
|
f7OverlAl_1 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Locked motor 7"
|
|
::= { alarms1 80 }
|
|
|
|
f7LowDCAl_1 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Low DC 7"
|
|
::= { alarms1 81 }
|
|
|
|
f8GeneralAl_1 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Fan general alarm 8"
|
|
::= { alarms1 82 }
|
|
|
|
f8PowerAl_1 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Phase failure/undervolt.8"
|
|
::= { alarms1 83 }
|
|
|
|
f8CommAl_1 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Communication 8"
|
|
::= { alarms1 84 }
|
|
|
|
f8HiTempAl_1 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Power mod overheated 8"
|
|
::= { alarms1 85 }
|
|
|
|
f8NetComAl_1 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Master/Slave com. 8"
|
|
::= { alarms1 86 }
|
|
|
|
f8InvRegAl_1 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Regulation module 8"
|
|
::= { alarms1 87 }
|
|
|
|
f8HiMotTAl_1 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Motor overheated 8"
|
|
::= { alarms1 88 }
|
|
|
|
f8HallSenAl_1 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Hall sensor error 8"
|
|
::= { alarms1 89 }
|
|
|
|
f8OverlAl_1 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Locked motor 8"
|
|
::= { alarms1 90 }
|
|
|
|
f8LowDCAl_1 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Low DC 8"
|
|
::= { alarms1 91 }
|
|
|
|
f9GeneralAl_1 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Fan general alarm 9"
|
|
::= { alarms1 92 }
|
|
|
|
f9PowerAl_1 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Phase failure/undervolt.9"
|
|
::= { alarms1 93 }
|
|
|
|
f9CommAl_1 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Communication 9"
|
|
::= { alarms1 94 }
|
|
|
|
f9HiTempAl_1 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Power mod overheated 9"
|
|
::= { alarms1 95 }
|
|
|
|
f9NetComAl_1 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Master/Slave com. 9"
|
|
::= { alarms1 96 }
|
|
|
|
f9InvRegAl_1 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Regulation module 9"
|
|
::= { alarms1 97 }
|
|
|
|
f9HiMotTAl_1 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Motor overheated 9"
|
|
::= { alarms1 98 }
|
|
|
|
f9HallSenAl_1 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Hall sensor error 9"
|
|
::= { alarms1 99 }
|
|
|
|
f9OverlAl_1 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Locked motor 9"
|
|
::= { alarms1 100 }
|
|
|
|
f9LowDCAl_1 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Low DC 9"
|
|
::= { alarms1 101 }
|
|
|
|
f10GenlAl_1 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Fan general alarm 10"
|
|
::= { alarms1 102 }
|
|
|
|
f10PowerAl_1 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Phase failure/undervolt.10"
|
|
::= { alarms1 103 }
|
|
|
|
f10CommAl_1 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Communication 10"
|
|
::= { alarms1 104 }
|
|
|
|
f10HiTempAl_1 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Power mod overheated 10"
|
|
::= { alarms1 105 }
|
|
|
|
f10NetComAl_1 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Master/Slave com. 10"
|
|
::= { alarms1 106 }
|
|
|
|
f10InvRegAl_1 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Regulation module 10"
|
|
::= { alarms1 107 }
|
|
|
|
f10HiMotTAl_1 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Motor overheated 10"
|
|
::= { alarms1 108 }
|
|
|
|
f10HallSAl_1 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Hall sensor error 10"
|
|
::= { alarms1 109 }
|
|
|
|
f10OverlAl_1 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Locked motor 10"
|
|
::= { alarms1 110 }
|
|
|
|
f10LowDCAl_1 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Low DC 10"
|
|
::= { alarms1 111 }
|
|
|
|
retTempPbAl_1 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Return temperature probe"
|
|
::= { alarms1 112 }
|
|
|
|
supTempPrAl_1 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Supply temperature probe"
|
|
::= { alarms1 113 }
|
|
|
|
retHumPrAl_1 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Return humidity probe"
|
|
::= { alarms1 114 }
|
|
|
|
supHumPrAl_1 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Supply humidity probe"
|
|
::= { alarms1 115 }
|
|
|
|
airPrSensAl_1 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Air diff.pressure probe"
|
|
::= { alarms1 116 }
|
|
|
|
watIN1PrAl_1 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Water temp. IN1 probe"
|
|
::= { alarms1 117 }
|
|
|
|
watOUT1PrAl_1 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Water temp. OUT1 probe"
|
|
::= { alarms1 118 }
|
|
|
|
watIN2PrAl_1 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Water temp. IN2 probe"
|
|
::= { alarms1 119 }
|
|
|
|
watOUT2PrAl_1 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Water temp. OUT2 probe"
|
|
::= { alarms1 120 }
|
|
|
|
watFlw1PrAl_1 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Water flow1/T.liquid1 pr."
|
|
::= { alarms1 121 }
|
|
|
|
watFlw2PrAl_1 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Water flow2/T.liquid2 pr."
|
|
::= { alarms1 122 }
|
|
|
|
dFPSGenAl_1 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Filter diff.press. probe"
|
|
::= { alarms1 123 }
|
|
|
|
dFPSBrokAl_1 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Breakdown alarm"
|
|
::= { alarms1 124 }
|
|
|
|
dFPSCablAl_1 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Wiring alarm"
|
|
::= { alarms1 125 }
|
|
|
|
dFPSRangeAl_1 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Pressure range alarm"
|
|
::= { alarms1 126 }
|
|
|
|
dFPSADCAl_1 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "ADC overload alarm"
|
|
::= { alarms1 127 }
|
|
|
|
dFPSSetAl_1 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Calibration alarm"
|
|
::= { alarms1 128 }
|
|
|
|
dFPSDCOAl_1 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "DCO alarm"
|
|
::= { alarms1 129 }
|
|
|
|
dFPSWatdAl_1 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Watchdog alarm"
|
|
::= { alarms1 130 }
|
|
|
|
dFPSCommAl_1 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Communication alarm"
|
|
::= { alarms1 131 }
|
|
|
|
invC1GenAl_1 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "DC inverter general alarm"
|
|
::= { alarms1 132 }
|
|
|
|
invC1CommAl_1 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Inverter communication"
|
|
::= { alarms1 133 }
|
|
|
|
c1ThermAl_1 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "C1 Thermal alarm"
|
|
::= { alarms1 134 }
|
|
|
|
c1HighPresAl_1 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "C1 High pressure alarm"
|
|
::= { alarms1 135 }
|
|
|
|
c1LowPresAl_1 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "C1 Low pressure alarm"
|
|
::= { alarms1 136 }
|
|
|
|
c1HighDiscAl_1 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "C1 High discharge alarm"
|
|
::= { alarms1 137 }
|
|
|
|
c1LCompRatAl_1 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "C1 low compresion alarm"
|
|
::= { alarms1 138 }
|
|
|
|
condenser1Al_1 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Condenser 1 general alarm"
|
|
::= { alarms1 139 }
|
|
|
|
c1WatFlowAl_1 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Condenser 1 flow alarm"
|
|
::= { alarms1 140 }
|
|
|
|
eEV1GenAl_1 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "EEV1 general alarm"
|
|
::= { alarms1 141 }
|
|
|
|
eEV1CommAl_1 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "EEV1 communication alarm"
|
|
::= { alarms1 142 }
|
|
|
|
eEV1SuctPrAl_1 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "EEV1 suction temp. probe"
|
|
::= { alarms1 143 }
|
|
|
|
eEV1EvapPrAl_1 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "EEV1 evap. temp. probe"
|
|
::= { alarms1 144 }
|
|
|
|
eEV1CondPrAl_1 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "EEV1 condens. temp. probe"
|
|
::= { alarms1 145 }
|
|
|
|
eEV1DiscPrAl_1 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "EEV1 disch. temp. probe"
|
|
::= { alarms1 146 }
|
|
|
|
c2ThermAl_1 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "C2 Thermal alarm"
|
|
::= { alarms1 147 }
|
|
|
|
c2HighPresAl_1 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "C2 High pressure alarm"
|
|
::= { alarms1 148 }
|
|
|
|
c2LowPresAl_1 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "C2 Low pressure alarm"
|
|
::= { alarms1 149 }
|
|
|
|
c2HighDiscAl_1 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "C2 High discharge alarm"
|
|
::= { alarms1 150 }
|
|
|
|
c2LCompRatAl_1 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "C2 low compresion alarm"
|
|
::= { alarms1 151 }
|
|
|
|
condenser2Al_1 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Condenser 2 general alarm"
|
|
::= { alarms1 152 }
|
|
|
|
c2WatFlowAl_1 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Condenser 2 flow alarm"
|
|
::= { alarms1 153 }
|
|
|
|
eEV2GenAl_1 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "EEV2 general alarm"
|
|
::= { alarms1 154 }
|
|
|
|
eEV2CommAl_1 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "EEV2 communication alarm"
|
|
::= { alarms1 155 }
|
|
|
|
eEV2SuctPrAl_1 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "EEV2 suction temp. probe"
|
|
::= { alarms1 156 }
|
|
|
|
eEV2EvapPrAl_1 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "EEV2 evap. temp. probe"
|
|
::= { alarms1 157 }
|
|
|
|
eEV2CondPrAl_1 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "EEV2 condens. temp. probe"
|
|
::= { alarms1 158 }
|
|
|
|
eEV2DiscPrAl_1 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "EEV2 disch. temp. probe"
|
|
::= { alarms1 159 }
|
|
|
|
intHumGenAl_1 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Internal humidifier alarm"
|
|
::= { alarms1 160 }
|
|
|
|
cPYCommAl_1 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Communication alarm"
|
|
::= { alarms1 161 }
|
|
|
|
cPYMemoryAl_1 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Memory error alarm"
|
|
::= { alarms1 162 }
|
|
|
|
cPYParamAl_1 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Parameters error alarm"
|
|
::= { alarms1 163 }
|
|
|
|
cPYHighCurAl_1 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Electrodes high current"
|
|
::= { alarms1 164 }
|
|
|
|
cPYLoSteamAl_1 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Low steam product. alarm"
|
|
::= { alarms1 165 }
|
|
|
|
cPYDrainAl_1 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Drain loss alarm"
|
|
::= { alarms1 166 }
|
|
|
|
cPYMaintAl_1 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Maintenance hours alarm"
|
|
::= { alarms1 167 }
|
|
|
|
cPYNoWaterAl_1 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Water loss alarm"
|
|
::= { alarms1 168 }
|
|
|
|
cPYCylMainAl_1 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Cylinder mainten. alarm"
|
|
::= { alarms1 169 }
|
|
|
|
cPYDirtCylAl_1 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Exaust cylinder alarm"
|
|
::= { alarms1 170 }
|
|
|
|
cPYFoamAl_1 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Foam presence alarm"
|
|
::= { alarms1 171 }
|
|
|
|
cPYLifeTimAl_1 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Life time expired alarm"
|
|
::= { alarms1 172 }
|
|
|
|
cPYHiWLevAl_1 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "High water level alarm"
|
|
::= { alarms1 173 }
|
|
|
|
cPYHWatConAl_1 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "High conductivity alarm"
|
|
::= { alarms1 174 }
|
|
|
|
cPYConnAl_1 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Connection error alarm"
|
|
::= { alarms1 175 }
|
|
|
|
watPresAl_1 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Water presence alarm"
|
|
::= { alarms1 176 }
|
|
|
|
drainPumpAl_1 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Drain pump alarm"
|
|
::= { alarms1 177 }
|
|
|
|
elHeatAl_1 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Electric heater alarm"
|
|
::= { alarms1 178 }
|
|
|
|
filterAl_1 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Dirty filter alarm"
|
|
::= { alarms1 179 }
|
|
|
|
dryCoolerAl_1 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Dry cooler alarm"
|
|
::= { alarms1 180 }
|
|
|
|
extHumidAl_1 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "External humidifier alarm"
|
|
::= { alarms1 181 }
|
|
|
|
waterPumpAl_1 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Water pump alarm"
|
|
::= { alarms1 182 }
|
|
|
|
condUnitGAl_1 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Motocondenser alarm"
|
|
::= { alarms1 183 }
|
|
|
|
gasLeakAl_1 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Refrigerant leak alarm"
|
|
::= { alarms1 184 }
|
|
|
|
powerSuppAl_1 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Power fault alarm"
|
|
::= { alarms1 185 }
|
|
|
|
genSoftAl_1 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Not critical generic al."
|
|
::= { alarms1 186 }
|
|
|
|
localNetAl_1 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Local network alarm"
|
|
::= { alarms1 187 }
|
|
|
|
regHiTempAl_1 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "High regulation T.alarm"
|
|
::= { alarms1 188 }
|
|
|
|
regLowTempAl_1 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Low regulation T.alarm"
|
|
::= { alarms1 189 }
|
|
|
|
hiLimTempAl_1 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "High limit temp. alarm"
|
|
::= { alarms1 190 }
|
|
|
|
lowLimTempAl_1 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Low limit temp. alarm"
|
|
::= { alarms1 191 }
|
|
|
|
retHiHumiAl_1 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "High room humidity alarm"
|
|
::= { alarms1 192 }
|
|
|
|
retLowHumiAl_1 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Low room humidity alarm"
|
|
::= { alarms1 193 }
|
|
|
|
supHiHumiAl_1 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "High supp.humidity alarm"
|
|
::= { alarms1 194 }
|
|
|
|
supLowHumiAl_1 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Low supp.humidity alarm"
|
|
::= { alarms1 195 }
|
|
|
|
probeMod1COM_1 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Module 1 communication"
|
|
::= { alarms1 196 }
|
|
|
|
prMod1err1_1 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Module 1 probe 1 alarm"
|
|
::= { alarms1 197 }
|
|
|
|
prMod1err2_1 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Module 1 probe 2 alarm"
|
|
::= { alarms1 198 }
|
|
|
|
prMod1err3_1 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Module 1 probe 3 alarm"
|
|
::= { alarms1 199 }
|
|
|
|
prMod1err4_1 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Module 1 probe 4 alarm"
|
|
::= { alarms1 200 }
|
|
|
|
prMod1err5_1 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Module 1 probe 5 alarm"
|
|
::= { alarms1 201 }
|
|
|
|
prMod1err6_1 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Module 1 probe 6 alarm"
|
|
::= { alarms1 202 }
|
|
|
|
probeMod2COM_1 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Module 2 communication"
|
|
::= { alarms1 203 }
|
|
|
|
prMod2err1_1 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Module 2 probe 1 alarm"
|
|
::= { alarms1 204 }
|
|
|
|
prMod2err2_1 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Module 2 probe 2 alarm"
|
|
::= { alarms1 205 }
|
|
|
|
prMod2err3_1 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Module 2 probe 3 alarm"
|
|
::= { alarms1 206 }
|
|
|
|
prMod2err4_1 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Module 2 probe 4 alarm"
|
|
::= { alarms1 207 }
|
|
|
|
prMod2err5_1 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Module 2 probe 5 alarm"
|
|
::= { alarms1 208 }
|
|
|
|
prMod2err6_1 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Module 2 probe 6 alarm"
|
|
::= { alarms1 209 }
|
|
|
|
probeMod3COM_1 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Module 3 communication"
|
|
::= { alarms1 210 }
|
|
|
|
prMod3err1_1 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Module 3 probe 1 alarm"
|
|
::= { alarms1 211 }
|
|
|
|
prMod3err2_1 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Module 3 probe 2 alarm"
|
|
::= { alarms1 212 }
|
|
|
|
prMod3err3_1 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Module 3 probe 3 alarm"
|
|
::= { alarms1 213 }
|
|
|
|
prMod3err4_1 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Module 3 probe 4 alarm"
|
|
::= { alarms1 214 }
|
|
|
|
prMod3err5_1 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Module 3 probe 5 alarm"
|
|
::= { alarms1 215 }
|
|
|
|
prMod3err6_1 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Module 3 probe 6 alarm"
|
|
::= { alarms1 216 }
|
|
|
|
node2 OBJECT IDENTIFIER ::= { tecnairlv 2 }
|
|
|
|
traps2 OBJECT IDENTIFIER ::= { node2 0 }
|
|
|
|
generalAlTrap_2 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
generalAl_2
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "General alarams"
|
|
::= { traps2 1 }
|
|
|
|
notCriticalAlTrap_2 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
notCriticalAl_2
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Not critical alarms"
|
|
::= { traps2 2 }
|
|
|
|
criticalAlTrap_2 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
criticalAl_2
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Critical alarms"
|
|
::= { traps2 3 }
|
|
|
|
fansAlTrap_2 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
fansAl_2
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Fans alarms"
|
|
::= { traps2 4 }
|
|
|
|
compAlTrap_2 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
compAl_2
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Compressors alarms"
|
|
::= { traps2 5 }
|
|
|
|
temperatureAlTrap_2 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
temperatureAl_2
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Temperature alarms"
|
|
::= { traps2 6 }
|
|
|
|
humidityAlTrap_2 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
humidityAl_2
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Humidity alarms"
|
|
::= { traps2 7 }
|
|
|
|
damperAlTrap_2 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
damperAl_2
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Damper status alarm"
|
|
::= { traps2 8 }
|
|
|
|
fireSmokeAlTrap_2 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
fireSmokeAl_2
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Fire/Smoke alarm"
|
|
::= { traps2 9 }
|
|
|
|
genSeriousAlTrap_2 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
genSeriousAl_2
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Critical generic alarm"
|
|
::= { traps2 10 }
|
|
|
|
fansGenAlTrap_2 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
fansGenAl_2
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "General supply fans alarm"
|
|
::= { traps2 11 }
|
|
|
|
f1GeneralAlTrap_2 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
f1GeneralAl_2
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Fan general alarm 1"
|
|
::= { traps2 12 }
|
|
|
|
f1PowerAlTrap_2 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
f1PowerAl_2
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Phase failure/undervolt.1"
|
|
::= { traps2 13 }
|
|
|
|
f1CommAlTrap_2 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
f1CommAl_2
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Communication 1"
|
|
::= { traps2 14 }
|
|
|
|
f1HighTempAlTrap_2 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
f1HighTempAl_2
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Power mod overheated 1"
|
|
::= { traps2 15 }
|
|
|
|
f1NetComAlTrap_2 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
f1NetComAl_2
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Master/Slave com. 1"
|
|
::= { traps2 16 }
|
|
|
|
f1InvRegAlTrap_2 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
f1InvRegAl_2
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Regulation module 1"
|
|
::= { traps2 17 }
|
|
|
|
f1HighMotTempAlTrap_2 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
f1HighMotTempAl_2
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Motor overheated 1"
|
|
::= { traps2 18 }
|
|
|
|
f1HallSensAlTrap_2 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
f1HallSensAl_2
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Hall sensor error 1"
|
|
::= { traps2 19 }
|
|
|
|
f1OverloadAlTrap_2 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
f1OverloadAl_2
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Locked motor 1"
|
|
::= { traps2 20 }
|
|
|
|
f1LowDCAlTrap_2 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
f1LowDCAl_2
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Low DC 1"
|
|
::= { traps2 21 }
|
|
|
|
f2GeneralAlTrap_2 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
f2GeneralAl_2
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Fan general alarm 2"
|
|
::= { traps2 22 }
|
|
|
|
f2PowerAlTrap_2 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
f2PowerAl_2
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Phase failure/undervolt.2"
|
|
::= { traps2 23 }
|
|
|
|
f2CommAlTrap_2 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
f2CommAl_2
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Communication 2"
|
|
::= { traps2 24 }
|
|
|
|
f2HighTempAlTrap_2 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
f2HighTempAl_2
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Power mod overheated 2"
|
|
::= { traps2 25 }
|
|
|
|
f2NetComAlTrap_2 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
f2NetComAl_2
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Master/Slave com. 2"
|
|
::= { traps2 26 }
|
|
|
|
f2InvRegAlTrap_2 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
f2InvRegAl_2
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Regulation module 2"
|
|
::= { traps2 27 }
|
|
|
|
f2HighMotTempAlTrap_2 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
f2HighMotTempAl_2
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Motor overheated 2"
|
|
::= { traps2 28 }
|
|
|
|
f2HallSensAlTrap_2 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
f2HallSensAl_2
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Hall sensor error 2"
|
|
::= { traps2 29 }
|
|
|
|
f2OverloadAlTrap_2 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
f2OverloadAl_2
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Locked motor 2"
|
|
::= { traps2 30 }
|
|
|
|
f2LowDCAlTrap_2 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
f2LowDCAl_2
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Low DC 2"
|
|
::= { traps2 31 }
|
|
|
|
f3GeneralAlTrap_2 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
f3GeneralAl_2
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Fan general alarm 3"
|
|
::= { traps2 32 }
|
|
|
|
f3PowerAlTrap_2 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
f3PowerAl_2
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Phase failure/undervolt.3"
|
|
::= { traps2 33 }
|
|
|
|
f3CommAlTrap_2 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
f3CommAl_2
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Communication 3"
|
|
::= { traps2 34 }
|
|
|
|
f3HighTempAlTrap_2 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
f3HighTempAl_2
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Power mod overheated 3"
|
|
::= { traps2 35 }
|
|
|
|
f3NetComAlTrap_2 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
f3NetComAl_2
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Master/Slave com. 3"
|
|
::= { traps2 36 }
|
|
|
|
f3InvRegAlTrap_2 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
f3InvRegAl_2
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Regulation module 3"
|
|
::= { traps2 37 }
|
|
|
|
f3HighMotTempAlTrap_2 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
f3HighMotTempAl_2
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Motor overheated 3"
|
|
::= { traps2 38 }
|
|
|
|
f3HallSensAlTrap_2 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
f3HallSensAl_2
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Hall sensor error 3"
|
|
::= { traps2 39 }
|
|
|
|
f3OverloadAlTrap_2 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
f3OverloadAl_2
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Locked motor 3"
|
|
::= { traps2 40 }
|
|
|
|
f3LowDCAlTrap_2 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
f3LowDCAl_2
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Low DC 3"
|
|
::= { traps2 41 }
|
|
|
|
f4GeneralAlTrap_2 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
f4GeneralAl_2
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Fan general alarm 4"
|
|
::= { traps2 42 }
|
|
|
|
f4PowerAlTrap_2 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
f4PowerAl_2
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Phase failure/undervolt.4"
|
|
::= { traps2 43 }
|
|
|
|
f4CommAlTrap_2 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
f4CommAl_2
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Communication 4"
|
|
::= { traps2 44 }
|
|
|
|
f4HighTempAlTrap_2 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
f4HighTempAl_2
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Power mod overheated 4"
|
|
::= { traps2 45 }
|
|
|
|
f4NetComAlTrap_2 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
f4NetComAl_2
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Master/Slave com. 4"
|
|
::= { traps2 46 }
|
|
|
|
f4InvRegAlTrap_2 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
f4InvRegAl_2
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Regulation module 4"
|
|
::= { traps2 47 }
|
|
|
|
f4HighMotTempAlTrap_2 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
f4HighMotTempAl_2
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Motor overheated 4"
|
|
::= { traps2 48 }
|
|
|
|
f4HallSensAlTrap_2 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
f4HallSensAl_2
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Hall sensor error 4"
|
|
::= { traps2 49 }
|
|
|
|
f4OverloadAlTrap_2 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
f4OverloadAl_2
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Locked motor 4"
|
|
::= { traps2 50 }
|
|
|
|
f4LowDCAlTrap_2 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
f4LowDCAl_2
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Low DC 4"
|
|
::= { traps2 51 }
|
|
|
|
f5GeneralAlTrap_2 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
f5GeneralAl_2
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Fan general alarm 5"
|
|
::= { traps2 52 }
|
|
|
|
f5PowerAlTrap_2 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
f5PowerAl_2
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Phase failure/undervolt.5"
|
|
::= { traps2 53 }
|
|
|
|
f5CommAlTrap_2 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
f5CommAl_2
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Communication 5"
|
|
::= { traps2 54 }
|
|
|
|
f5HighTempAlTrap_2 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
f5HighTempAl_2
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Power mod overheated 5"
|
|
::= { traps2 55 }
|
|
|
|
f5NetComAlTrap_2 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
f5NetComAl_2
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Master/Slave com. 5"
|
|
::= { traps2 56 }
|
|
|
|
f5InvRegAlTrap_2 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
f5InvRegAl_2
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Regulation module 5"
|
|
::= { traps2 57 }
|
|
|
|
f5HighMotTempAlTrap_2 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
f5HighMotTempAl_2
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Motor overheated 5"
|
|
::= { traps2 58 }
|
|
|
|
f5HallSensAlTrap_2 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
f5HallSensAl_2
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Hall sensor error 5"
|
|
::= { traps2 59 }
|
|
|
|
f5OverloadAlTrap_2 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
f5OverloadAl_2
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Locked motor 5"
|
|
::= { traps2 60 }
|
|
|
|
f5LowDCAlTrap_2 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
f5LowDCAl_2
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Low DC 5"
|
|
::= { traps2 61 }
|
|
|
|
f6GeneralAlTrap_2 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
f6GeneralAl_2
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Fan general alarm 6"
|
|
::= { traps2 62 }
|
|
|
|
f6PowerAlTrap_2 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
f6PowerAl_2
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Phase failure/undervolt.6"
|
|
::= { traps2 63 }
|
|
|
|
f6CommAlTrap_2 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
f6CommAl_2
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Communication 6"
|
|
::= { traps2 64 }
|
|
|
|
f6HighTempAlTrap_2 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
f6HighTempAl_2
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Power mod overheated 6"
|
|
::= { traps2 65 }
|
|
|
|
f6NetComAlTrap_2 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
f6NetComAl_2
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Master/Slave com. 6"
|
|
::= { traps2 66 }
|
|
|
|
f6InvRegAlTrap_2 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
f6InvRegAl_2
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Regulation module 6"
|
|
::= { traps2 67 }
|
|
|
|
f6HighMotTempAlTrap_2 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
f6HighMotTempAl_2
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Motor overheated 6"
|
|
::= { traps2 68 }
|
|
|
|
f6HallSensAlTrap_2 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
f6HallSensAl_2
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Hall sensor error 6"
|
|
::= { traps2 69 }
|
|
|
|
f6OverloadAlTrap_2 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
f6OverloadAl_2
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Locked motor 6"
|
|
::= { traps2 70 }
|
|
|
|
f6LowDCAlTrap_2 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
f6LowDCAl_2
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Low DC 6"
|
|
::= { traps2 71 }
|
|
|
|
f7GeneralAlTrap_2 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
f7GeneralAl_2
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Fan general alarm 7"
|
|
::= { traps2 72 }
|
|
|
|
f7PowerAlTrap_2 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
f7PowerAl_2
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Phase failure/undervolt.7"
|
|
::= { traps2 73 }
|
|
|
|
f7CommAlTrap_2 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
f7CommAl_2
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Communication 7"
|
|
::= { traps2 74 }
|
|
|
|
f7HighTempAlTrap_2 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
f7HighTempAl_2
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Power mod overheated 7"
|
|
::= { traps2 75 }
|
|
|
|
f7NetComAlTrap_2 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
f7NetComAl_2
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Master/Slave com. 7"
|
|
::= { traps2 76 }
|
|
|
|
f7InvRegAlTrap_2 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
f7InvRegAl_2
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Regulation module 7"
|
|
::= { traps2 77 }
|
|
|
|
f7HighMotTempAlTrap_2 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
f7HighMotTempAl_2
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Motor overheated 7"
|
|
::= { traps2 78 }
|
|
|
|
f7HallSensAlTrap_2 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
f7HallSensAl_2
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Hall sensor error 7"
|
|
::= { traps2 79 }
|
|
|
|
f7OverloadAlTrap_2 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
f7OverloadAl_2
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Locked motor 7"
|
|
::= { traps2 80 }
|
|
|
|
f7LowDCAlTrap_2 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
f7LowDCAl_2
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Low DC 7"
|
|
::= { traps2 81 }
|
|
|
|
f8GeneralAlTrap_2 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
f8GeneralAl_2
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Fan general alarm 8"
|
|
::= { traps2 82 }
|
|
|
|
f8PowerAlTrap_2 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
f8PowerAl_2
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Phase failure/undervolt.8"
|
|
::= { traps2 83 }
|
|
|
|
f8CommAlTrap_2 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
f8CommAl_2
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Communication 8"
|
|
::= { traps2 84 }
|
|
|
|
f8HighTempAlTrap_2 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
f8HighTempAl_2
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Power mod overheated 8"
|
|
::= { traps2 85 }
|
|
|
|
f8NetComAlTrap_2 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
f8NetComAl_2
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Master/Slave com. 8"
|
|
::= { traps2 86 }
|
|
|
|
f8InvRegAlTrap_2 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
f8InvRegAl_2
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Regulation module 8"
|
|
::= { traps2 87 }
|
|
|
|
f8HighMotTempAlTrap_2 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
f8HighMotTempAl_2
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Motor overheated 8"
|
|
::= { traps2 88 }
|
|
|
|
f8HallSensAlTrap_2 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
f8HallSensAl_2
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Hall sensor error 8"
|
|
::= { traps2 89 }
|
|
|
|
f8OverloadAlTrap_2 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
f8OverloadAl_2
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Locked motor 8"
|
|
::= { traps2 90 }
|
|
|
|
f8LowDCAlTrap_2 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
f8LowDCAl_2
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Low DC 8"
|
|
::= { traps2 91 }
|
|
|
|
f9InverterAlTrap_2 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
f9InverterAl_2
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Fan general alarm 9"
|
|
::= { traps2 92 }
|
|
|
|
f9PowerAlTrap_2 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
f9PowerAl_2
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Phase failure/undervolt.9"
|
|
::= { traps2 93 }
|
|
|
|
f9CommAlTrap_2 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
f9CommAl_2
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Communication 9"
|
|
::= { traps2 94 }
|
|
|
|
f9HighTempAlTrap_2 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
f9HighTempAl_2
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Power mod overheated 9"
|
|
::= { traps2 95 }
|
|
|
|
f9NetComAlTrap_2 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
f9NetComAl_2
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Master/Slave com. 9"
|
|
::= { traps2 96 }
|
|
|
|
f9InvRegAlTrap_2 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
f9InvRegAl_2
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Regulation module 9"
|
|
::= { traps2 97 }
|
|
|
|
f9HighMotTempAlTrap_2 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
f9HighMotTempAl_2
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Motor overheated 9"
|
|
::= { traps2 98 }
|
|
|
|
f9HallSensAlTrap_2 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
f9HallSensAl_2
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Hall sensor error 9"
|
|
::= { traps2 99 }
|
|
|
|
f9OverloadAlTrap_2 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
f9OverloadAl_2
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Locked motor 9"
|
|
::= { traps2 100 }
|
|
|
|
f9LowDCAlTrap_2 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
f9LowDCAl_2
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Low DC 9"
|
|
::= { traps2 101 }
|
|
|
|
f10GeneralAlTrap_2 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
f10GeneralAl_2
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Fan general alarm 10"
|
|
::= { traps2 102 }
|
|
|
|
f10PowerAlTrap_2 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
f10PowerAl_2
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Phase failure/undervolt.10"
|
|
::= { traps2 103 }
|
|
|
|
f10CommAlTrap_2 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
f10CommAl_2
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Communication 10"
|
|
::= { traps2 104 }
|
|
|
|
f10HighTempAlTrap_2 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
f10HighTempAl_2
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Power mod overheated 10"
|
|
::= { traps2 105 }
|
|
|
|
f10NetComAlTrap_2 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
f10NetComAl_2
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Master/Slave com. 10"
|
|
::= { traps2 106 }
|
|
|
|
f10InvRegAlTrap_2 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
f10InvRegAl_2
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Regulation module 10"
|
|
::= { traps2 107 }
|
|
|
|
f10HighMotTAlTrap_2 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
f10HighMotTAl_2
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Motor overheated 10"
|
|
::= { traps2 108 }
|
|
|
|
f10HallSensAlTrap_2 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
f10HallSensAl_2
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Hall sensor error 10"
|
|
::= { traps2 109 }
|
|
|
|
f10OverloadAlTrap_2 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
f10OverloadAl_2
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Locked motor 10"
|
|
::= { traps2 110 }
|
|
|
|
f10LowDCAlTrap_2 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
f10LowDCAl_2
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Low DC 10"
|
|
::= { traps2 111 }
|
|
|
|
retTempProbAlTrap_2 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
retTempProbAl_2
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Return temperature probe"
|
|
::= { traps2 112 }
|
|
|
|
supTempProbAlTrap_2 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
supTempProbAl_2
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Supply temperature probe"
|
|
::= { traps2 113 }
|
|
|
|
retHumProbAlTrap_2 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
retHumProbAl_2
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Return humidity probe"
|
|
::= { traps2 114 }
|
|
|
|
supHumProbAlTrap_2 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
supHumProbAl_2
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Supply humidity probe"
|
|
::= { traps2 115 }
|
|
|
|
airPrSensorAlTrap_2 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
airPrSensorAl_2
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Air diff.pressure probe"
|
|
::= { traps2 116 }
|
|
|
|
watIN1ProbAlTrap_2 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
watIN1ProbAl_2
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Water temp. IN1 probe"
|
|
::= { traps2 117 }
|
|
|
|
watOUT1ProbAlTrap_2 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
watOUT1ProbAl_2
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Water temp. OUT1 probe"
|
|
::= { traps2 118 }
|
|
|
|
watIN2ProbAlTrap_2 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
watIN2ProbAl_2
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Water temp. IN2 probe"
|
|
::= { traps2 119 }
|
|
|
|
watOUT2ProbAlTrap_2 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
watOUT2ProbAl_2
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Water temp. OUT2 probe"
|
|
::= { traps2 120 }
|
|
|
|
watFlw1ProbAlTrap_2 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
watFlw1ProbAl_2
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Water flow1/T.liquid1 pr."
|
|
::= { traps2 121 }
|
|
|
|
watFlw2ProbAlTrap_2 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
watFlw2ProbAl_2
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Water flow2/T.liquid2 pr."
|
|
::= { traps2 122 }
|
|
|
|
dFPSGenAlTrap_2 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
dFPSGenAl_2
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Filter diff.press. probe"
|
|
::= { traps2 123 }
|
|
|
|
dFPSBrokenAlTrap_2 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
dFPSBrokenAl_2
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Breakdown alarm"
|
|
::= { traps2 124 }
|
|
|
|
dFPSCablingAlTrap_2 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
dFPSCablingAl_2
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Wiring alarm"
|
|
::= { traps2 125 }
|
|
|
|
dFPSRangeAlTrap_2 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
dFPSRangeAl_2
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Pressure range alarm"
|
|
::= { traps2 126 }
|
|
|
|
dFPSADCAlTrap_2 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
dFPSADCAl_2
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "ADC overload alarm"
|
|
::= { traps2 127 }
|
|
|
|
dFPSSettingAlTrap_2 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
dFPSSettingAl_2
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Calibration alarm"
|
|
::= { traps2 128 }
|
|
|
|
dFPSDCOAlTrap_2 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
dFPSDCOAl_2
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "DCO alarm"
|
|
::= { traps2 129 }
|
|
|
|
dFPSWatchdogAlTrap_2 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
dFPSWatchdogAl_2
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Watchdog alarm"
|
|
::= { traps2 130 }
|
|
|
|
dFPSCommAlTrap_2 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
dFPSCommAl_2
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Communication alarm"
|
|
::= { traps2 131 }
|
|
|
|
invCompGenAlTrap_2 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
invCompGenAl_2
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "DC inverter general alarm"
|
|
::= { traps2 132 }
|
|
|
|
invCompCommAlTrap_2 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
invCompCommAl_2
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Inverter communication"
|
|
::= { traps2 133 }
|
|
|
|
invCompAlCode1Trap_2 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
invCompAlCode1_2
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "DC Inverter alarm code 1"
|
|
::= { traps2 134 }
|
|
|
|
invCompAlCode2Trap_2 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
invCompAlCode2_2
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "DC Inverter alarm code 2"
|
|
::= { traps2 135 }
|
|
|
|
invCompAlCode3Trap_2 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
invCompAlCode3_2
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "DC Inverter alarm code 3"
|
|
::= { traps2 136 }
|
|
|
|
invCompAlCode4Trap_2 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
invCompAlCode4_2
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "DC Inverter alarm code 4"
|
|
::= { traps2 137 }
|
|
|
|
invCompAlCode5Trap_2 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
invCompAlCode5_2
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "DC Inverter alarm code 5"
|
|
::= { traps2 138 }
|
|
|
|
c1ThermAlTrap_2 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
c1ThermAl_2
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "C1 Thermal alarm"
|
|
::= { traps2 139 }
|
|
|
|
c1HighPresAlTrap_2 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
c1HighPresAl_2
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "C1 High pressure alarm"
|
|
::= { traps2 140 }
|
|
|
|
c1LowPresAlTrap_2 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
c1LowPresAl_2
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "C1 Low pressure alarm"
|
|
::= { traps2 141 }
|
|
|
|
c1HighDischAlTrap_2 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
c1HighDischAl_2
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "C1 High discharge alarm"
|
|
::= { traps2 142 }
|
|
|
|
c1LCompRatAlTrap_2 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
c1LCompRatAl_2
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "C1 low compresion alarm"
|
|
::= { traps2 143 }
|
|
|
|
condenser1AlTrap_2 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
condenser1Al_2
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Condenser 1 general alarm"
|
|
::= { traps2 144 }
|
|
|
|
c1WatFlowAlTrap_2 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
c1WatFlowAl_2
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Condenser 1 flow alarm"
|
|
::= { traps2 145 }
|
|
|
|
eEV1GenAlTrap_2 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
eEV1GenAl_2
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "EEV1 general alarm"
|
|
::= { traps2 146 }
|
|
|
|
eEV1CommAlTrap_2 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
eEV1CommAl_2
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "EEV1 communication alarm"
|
|
::= { traps2 147 }
|
|
|
|
eEV1SuctProbAlTrap_2 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
eEV1SuctProbAl_2
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "EEV1 suction temp. probe"
|
|
::= { traps2 148 }
|
|
|
|
eEV1EvapProbAlTrap_2 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
eEV1EvapProbAl_2
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "EEV1 evap. temp. probe"
|
|
::= { traps2 149 }
|
|
|
|
eEV1CondProbAlTrap_2 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
eEV1CondProbAl_2
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "EEV1 condens. temp. probe"
|
|
::= { traps2 150 }
|
|
|
|
eEV1DischProbAlTrap_2 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
eEV1DischProbAl_2
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "EEV1 disch. temp. probe"
|
|
::= { traps2 151 }
|
|
|
|
c2ThermAlTrap_2 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
c2ThermAl_2
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "C2 Thermal alarm"
|
|
::= { traps2 152 }
|
|
|
|
c2HighPresAlTrap_2 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
c2HighPresAl_2
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "C2 High pressure alarm"
|
|
::= { traps2 153 }
|
|
|
|
c2LowPresAlTrap_2 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
c2LowPresAl_2
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "C2 Low pressure alarm"
|
|
::= { traps2 154 }
|
|
|
|
c2HighDischAlTrap_2 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
c2HighDischAl_2
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "C2 High discharge alarm"
|
|
::= { traps2 155 }
|
|
|
|
c2LCompRatAlTrap_2 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
c2LCompRatAl_2
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "C2 low compresion alarm"
|
|
::= { traps2 156 }
|
|
|
|
condenser2AlTrap_2 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
condenser2Al_2
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Condenser 2 general alarm"
|
|
::= { traps2 157 }
|
|
|
|
c2WatFlowAlTrap_2 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
c2WatFlowAl_2
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Condenser 2 flow alarm"
|
|
::= { traps2 158 }
|
|
|
|
eEV2GenAlTrap_2 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
eEV2GenAl_2
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "EEV2 general alarm"
|
|
::= { traps2 159 }
|
|
|
|
eEV2CommAlTrap_2 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
eEV2CommAl_2
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "EEV2 communication alarm"
|
|
::= { traps2 160 }
|
|
|
|
eEV2SuctProbAlTrap_2 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
eEV2SuctProbAl_2
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "EEV2 suction temp. probe"
|
|
::= { traps2 161 }
|
|
|
|
eEV2EvapProbAlTrap_2 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
eEV2EvapProbAl_2
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "EEV2 evap. temp. probe"
|
|
::= { traps2 162 }
|
|
|
|
eEV2CondProbAlTrap_2 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
eEV2CondProbAl_2
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "EEV2 condens. temp. probe"
|
|
::= { traps2 163 }
|
|
|
|
eEV2DischProbAlTrap_2 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
eEV2DischProbAl_2
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "EEV2 disch. temp. probe"
|
|
::= { traps2 164 }
|
|
|
|
intHumidGenAlTrap_2 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
intHumidGenAl_2
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Internal humidifier alarm"
|
|
::= { traps2 165 }
|
|
|
|
cPYCommAlTrap_2 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
cPYCommAl_2
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Communication alarm"
|
|
::= { traps2 166 }
|
|
|
|
cPYMemoryAlTrap_2 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
cPYMemoryAl_2
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Memory error alarm"
|
|
::= { traps2 167 }
|
|
|
|
cPYParameterAlTrap_2 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
cPYParameterAl_2
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Parameters error alarm"
|
|
::= { traps2 168 }
|
|
|
|
cPYHighCurrAlTrap_2 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
cPYHighCurrAl_2
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Electrodes high current"
|
|
::= { traps2 169 }
|
|
|
|
cPYLowSteamAlTrap_2 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
cPYLowSteamAl_2
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Low steam product. alarm"
|
|
::= { traps2 170 }
|
|
|
|
cPYDrainAlTrap_2 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
cPYDrainAl_2
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Drain loss alarm"
|
|
::= { traps2 171 }
|
|
|
|
cPYMaintAlTrap_2 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
cPYMaintAl_2
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Maintenance hours alarm"
|
|
::= { traps2 172 }
|
|
|
|
cPYNoWaterAlTrap_2 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
cPYNoWaterAl_2
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Water loss alarm"
|
|
::= { traps2 173 }
|
|
|
|
cPYCylMaintAlTrap_2 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
cPYCylMaintAl_2
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Cylinder mainten. alarm"
|
|
::= { traps2 174 }
|
|
|
|
cPYDirtyCylAlTrap_2 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
cPYDirtyCylAl_2
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Exaust cylinder alarm"
|
|
::= { traps2 175 }
|
|
|
|
cPYFoamAlTrap_2 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
cPYFoamAl_2
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Foam presence alarm"
|
|
::= { traps2 176 }
|
|
|
|
cPYLifeTimeAlTrap_2 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
cPYLifeTimeAl_2
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Life time expired alarm"
|
|
::= { traps2 177 }
|
|
|
|
cPYHighWatLevAlTrap_2 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
cPYHighWatLevAl_2
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "High water level alarm"
|
|
::= { traps2 178 }
|
|
|
|
cPYHWatCondAlTrap_2 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
cPYHWatCondAl_2
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "High conductivity alarm"
|
|
::= { traps2 179 }
|
|
|
|
cPYConnectionAlTrap_2 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
cPYConnectionAl_2
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Connection error alarm"
|
|
::= { traps2 180 }
|
|
|
|
watPresAlTrap_2 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
watPresAl_2
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Water presence alarm"
|
|
::= { traps2 181 }
|
|
|
|
drainPumpAlTrap_2 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
drainPumpAl_2
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Drain pump alarm"
|
|
::= { traps2 182 }
|
|
|
|
elHeatAlTrap_2 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
elHeatAl_2
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Electric heater alarm"
|
|
::= { traps2 183 }
|
|
|
|
filterAlTrap_2 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
filterAl_2
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Dirty filter alarm"
|
|
::= { traps2 184 }
|
|
|
|
dryCoolerAlTrap_2 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
dryCoolerAl_2
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Dry cooler alarm"
|
|
::= { traps2 185 }
|
|
|
|
extHumidAlTrap_2 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
extHumidAl_2
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "External humidifier alarm"
|
|
::= { traps2 186 }
|
|
|
|
waterPumpAlTrap_2 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
waterPumpAl_2
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Water pump alarm"
|
|
::= { traps2 187 }
|
|
|
|
condUnitGenAlTrap_2 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
condUnitGenAl_2
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Motocondenser alarm"
|
|
::= { traps2 188 }
|
|
|
|
gasLeakAlTrap_2 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
gasLeakAl_2
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Refrigerant leak alarm"
|
|
::= { traps2 189 }
|
|
|
|
powerSupplyAlTrap_2 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
powerSupplyAl_2
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Power fault alarm"
|
|
::= { traps2 190 }
|
|
|
|
genericSoftAlTrap_2 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
genericSoftAl_2
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Not critical generic al."
|
|
::= { traps2 191 }
|
|
|
|
localNetworkAlTrap_2 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
localNetworkAl_2
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Local network alarm"
|
|
::= { traps2 192 }
|
|
|
|
regHighTempAlTrap_2 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
regHighTempAl_2
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "High regulation T.alarm"
|
|
::= { traps2 193 }
|
|
|
|
regLowTempAlTrap_2 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
regLowTempAl_2
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Low regulation T.alarm"
|
|
::= { traps2 194 }
|
|
|
|
highLimTempAlTrap_2 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
highLimTempAl_2
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "High limit temp. alarm"
|
|
::= { traps2 195 }
|
|
|
|
lowLimTempAlTrap_2 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
lowLimTempAl_2
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Low limit temp. alarm"
|
|
::= { traps2 196 }
|
|
|
|
retHighHumiAlTrap_2 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
retHighHumiAl_2
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "High room humidity alarm"
|
|
::= { traps2 197 }
|
|
|
|
retLowHumiAlTrap_2 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
retLowHumiAl_2
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Low room humidity alarm"
|
|
::= { traps2 198 }
|
|
|
|
supHighHumiAlTrap_2 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
supHighHumiAl_2
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "High supp.humidity alarm"
|
|
::= { traps2 199 }
|
|
|
|
supLowHumiAlTrap_2 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
supLowHumiAl_2
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Low supp.humidity alarm"
|
|
::= { traps2 200 }
|
|
|
|
probeMod1COMTrap_2 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
probeMod1COM_2
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Module 1 communication"
|
|
::= { traps2 201 }
|
|
|
|
probeMod1err1Trap_2 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
probeMod1err1_2
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Module 1 probe 1 alarm"
|
|
::= { traps2 202 }
|
|
|
|
probeMod1err2Trap_2 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
probeMod1err2_2
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Module 1 probe 2 alarm"
|
|
::= { traps2 203 }
|
|
|
|
probeMod1err3Trap_2 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
probeMod1err3_2
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Module 1 probe 3 alarm"
|
|
::= { traps2 204 }
|
|
|
|
probeMod1err4Trap_2 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
probeMod1err4_2
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Module 1 probe 4 alarm"
|
|
::= { traps2 205 }
|
|
|
|
probeMod1err5Trap_2 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
probeMod1err5_2
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Module 1 probe 5 alarm"
|
|
::= { traps2 206 }
|
|
|
|
probeMod1err6Trap_2 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
probeMod1err6_2
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Module 1 probe 6 alarm"
|
|
::= { traps2 207 }
|
|
|
|
probeMod2COMTrap_2 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
probeMod2COM_2
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Module 2 communication"
|
|
::= { traps2 208 }
|
|
|
|
probeMod2err1Trap_2 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
probeMod2err1_2
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Module 2 probe 1 alarm"
|
|
::= { traps2 209 }
|
|
|
|
probeMod2err2Trap_2 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
probeMod2err2_2
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Module 2 probe 2 alarm"
|
|
::= { traps2 210 }
|
|
|
|
probeMod2err3Trap_2 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
probeMod2err3_2
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Module 2 probe 3 alarm"
|
|
::= { traps2 211 }
|
|
|
|
probeMod2err4Trap_2 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
probeMod2err4_2
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Module 2 probe 4 alarm"
|
|
::= { traps2 212 }
|
|
|
|
probeMod2err5Trap_2 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
probeMod2err5_2
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Module 2 probe 5 alarm"
|
|
::= { traps2 213 }
|
|
|
|
probeMod2err6Trap_2 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
probeMod2err6_2
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Module 2 probe 6 alarm"
|
|
::= { traps2 214 }
|
|
|
|
probeMod3COMTrap_2 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
probeMod3COM_2
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Module 3 communication"
|
|
::= { traps2 215 }
|
|
|
|
probeMod3err1Trap_2 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
probeMod3err1_2
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Module 3 probe 1 alarm"
|
|
::= { traps2 216 }
|
|
|
|
probeMod3err2Trap_2 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
probeMod3err2_2
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Module 3 probe 2 alarm"
|
|
::= { traps2 217 }
|
|
|
|
probeMod3err3Trap_2 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
probeMod3err3_2
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Module 3 probe 3 alarm"
|
|
::= { traps2 218 }
|
|
|
|
probeMod3err4Trap_2 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
probeMod3err4_2
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Module 3 probe 4 alarm"
|
|
::= { traps2 219 }
|
|
|
|
probeMod3err5Trap_2 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
probeMod3err5_2
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Module 3 probe 5 alarm"
|
|
::= { traps2 220 }
|
|
|
|
probeMod3err6Trap_2 NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
probeMod3err6_2
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Module 3 probe 6 alarm"
|
|
::= { traps2 221 }
|
|
|
|
binaryObjects2 OBJECT IDENTIFIER ::= { node2 1 }
|
|
|
|
damperStatusDI_2 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Motorised damper status"
|
|
::= { binaryObjects2 1 }
|
|
|
|
dirtyFilterDI_2 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Dirty filter alarm"
|
|
::= { binaryObjects2 2 }
|
|
|
|
remoteOffDI_2 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Remote OFF status"
|
|
::= { binaryObjects2 3 }
|
|
|
|
elHeaterAlarmDI_2 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Heater thermostat alarm"
|
|
::= { binaryObjects2 4 }
|
|
|
|
condPumpAlarmDI_2 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Condensate pump alarm"
|
|
::= { binaryObjects2 5 }
|
|
|
|
configurableDI1_2 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Configurable DI 1"
|
|
::= { binaryObjects2 6 }
|
|
|
|
configurableDI2_2 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Configurable DI 2"
|
|
::= { binaryObjects2 7 }
|
|
|
|
configurableDI3_2 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Configurable DI 3"
|
|
::= { binaryObjects2 8 }
|
|
|
|
configurableDI4_2 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Configurable DI 4"
|
|
::= { binaryObjects2 9 }
|
|
|
|
configurableDI5_2 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Configurable DI 5"
|
|
::= { binaryObjects2 10 }
|
|
|
|
c1ThermAlarmDI_2 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Comp1 thermal alarm"
|
|
::= { binaryObjects2 11 }
|
|
|
|
c1HPAlarmDI_2 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Comp1 high pressure alarm"
|
|
::= { binaryObjects2 12 }
|
|
|
|
c1LPAlarmDI_2 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Comp1 low pressure alarm"
|
|
::= { binaryObjects2 13 }
|
|
|
|
c2ThermAlarmDI_2 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Comp2 thermal alarm"
|
|
::= { binaryObjects2 14 }
|
|
|
|
c2HPAlarmDI_2 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Comp2 high pressure alarm"
|
|
::= { binaryObjects2 15 }
|
|
|
|
c2LPAlarmDI_2 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Comp2 low pressure alarm"
|
|
::= { binaryObjects2 16 }
|
|
|
|
fansDO_2 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Fan control"
|
|
::= { binaryObjects2 17 }
|
|
|
|
damperDO_2 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Motorised dampers control"
|
|
::= { binaryObjects2 18 }
|
|
|
|
configurableDO1_2 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Configurable DO 1"
|
|
::= { binaryObjects2 19 }
|
|
|
|
configurableDO2_2 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Configurable DO 2"
|
|
::= { binaryObjects2 20 }
|
|
|
|
configurableDO3_2 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Configurable DO 3"
|
|
::= { binaryObjects2 21 }
|
|
|
|
configurableDO4_2 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Configurable DO 4"
|
|
::= { binaryObjects2 22 }
|
|
|
|
configurableDO5_2 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Configurable DO 5"
|
|
::= { binaryObjects2 23 }
|
|
|
|
eHeaterStage1DO_2 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Electric heat stage 1"
|
|
::= { binaryObjects2 24 }
|
|
|
|
eHeaterStage2DO_2 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Electric heat stage 2"
|
|
::= { binaryObjects2 25 }
|
|
|
|
compressor1DO_2 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Compressor 1 control"
|
|
::= { binaryObjects2 26 }
|
|
|
|
compressor2DO_2 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Compressor 2 control"
|
|
::= { binaryObjects2 27 }
|
|
|
|
humPowerDO_2 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Humidifier control"
|
|
::= { binaryObjects2 28 }
|
|
|
|
humDrainValveDO_2 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Humidifier Discharge"
|
|
::= { binaryObjects2 29 }
|
|
|
|
humFillValveDO_2 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Humidifier Charging"
|
|
::= { binaryObjects2 30 }
|
|
|
|
humWaterLevel_2 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Humidifier high water"
|
|
::= { binaryObjects2 31 }
|
|
|
|
supervOFF_2 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "ON/OFF from supervisor"
|
|
::= { binaryObjects2 32 }
|
|
|
|
enableHumid_2 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Humidification enabling"
|
|
::= { binaryObjects2 33 }
|
|
|
|
humManualDrain_2 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Manual draining"
|
|
::= { binaryObjects2 34 }
|
|
|
|
humCylWashing_2 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Cylinder washing"
|
|
::= { binaryObjects2 35 }
|
|
|
|
tSManExchange_2 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "TS manual exchange"
|
|
::= { binaryObjects2 36 }
|
|
|
|
tSTempExchEnab_2 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Enable TS room temp. exc."
|
|
::= { binaryObjects2 37 }
|
|
|
|
damperAlRes_2 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Reset damper status AL"
|
|
::= { binaryObjects2 38 }
|
|
|
|
fireSmokeAlRes_2 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Reset smoke/fire AL"
|
|
::= { binaryObjects2 39 }
|
|
|
|
genSerAlRes_2 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Reset generic serious AL"
|
|
::= { binaryObjects2 40 }
|
|
|
|
fansGenAlRes_2 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Reset supply fan AL"
|
|
::= { binaryObjects2 41 }
|
|
|
|
f1InvAlRes_2 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Reset fan 1 alarm"
|
|
::= { binaryObjects2 42 }
|
|
|
|
f2InvAlRes_2 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Reset fan 2 alarm"
|
|
::= { binaryObjects2 43 }
|
|
|
|
f3InvAlRes_2 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Reset fan 3 alarm"
|
|
::= { binaryObjects2 44 }
|
|
|
|
f4InvAlRes_2 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Reset fan 4 alarm"
|
|
::= { binaryObjects2 45 }
|
|
|
|
f5InvAlRes_2 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Reset fan 5 alarm"
|
|
::= { binaryObjects2 46 }
|
|
|
|
f6InvAlRes_2 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Reset fan 6 alarm"
|
|
::= { binaryObjects2 47 }
|
|
|
|
f7InvAlRes_2 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Reset fan 7 alarm"
|
|
::= { binaryObjects2 48 }
|
|
|
|
f8InvAlRes_2 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Reset fan 8 alarm"
|
|
::= { binaryObjects2 49 }
|
|
|
|
f9InvAlRes_2 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Reset fan 9 alarm"
|
|
::= { binaryObjects2 50 }
|
|
|
|
f10InvAlRes_2 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Reset fan 10 alarm"
|
|
::= { binaryObjects2 51 }
|
|
|
|
invCompAlRes_2 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Reset inverter alarm"
|
|
::= { binaryObjects2 52 }
|
|
|
|
c1ThermAlRes_2 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Reset C1 thermal AL"
|
|
::= { binaryObjects2 53 }
|
|
|
|
c1HighPresAlRes_2 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Reset C1 high pressure AL"
|
|
::= { binaryObjects2 54 }
|
|
|
|
c1LowPresAlRes_2 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Reset C1 low pressure AL"
|
|
::= { binaryObjects2 55 }
|
|
|
|
c1HighDisTAlRes_2 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Reset C1 high disch. AL"
|
|
::= { binaryObjects2 56 }
|
|
|
|
c1LCompRatAlRes_2 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Reset C1 low compres. AL"
|
|
::= { binaryObjects2 57 }
|
|
|
|
condenser1AlRes_2 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Reset condenser 1 AL"
|
|
::= { binaryObjects2 58 }
|
|
|
|
eEV1AlRes_2 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Reset EEV1 alarm"
|
|
::= { binaryObjects2 59 }
|
|
|
|
c2ThermAlRes_2 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Reset C2 thermal AL"
|
|
::= { binaryObjects2 60 }
|
|
|
|
c2HighPresAlRes_2 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Reset C2 high pressure AL"
|
|
::= { binaryObjects2 61 }
|
|
|
|
c2LowPresAlRes_2 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Reset C2 low pressure AL"
|
|
::= { binaryObjects2 62 }
|
|
|
|
c2HighDisTAlRes_2 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Reset C2 high disch. AL"
|
|
::= { binaryObjects2 63 }
|
|
|
|
c2LComRatAlRes_2 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Reset C2 low compres. AL"
|
|
::= { binaryObjects2 64 }
|
|
|
|
condenser2AlRes_2 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Reset condenser 2 AL"
|
|
::= { binaryObjects2 65 }
|
|
|
|
eEV2AlRes_2 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Reset EEV2 alarm"
|
|
::= { binaryObjects2 66 }
|
|
|
|
intHumidifAlRes_2 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Reset int. humidifier AL"
|
|
::= { binaryObjects2 67 }
|
|
|
|
watPresAlRes_2 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Reset water presence AL"
|
|
::= { binaryObjects2 68 }
|
|
|
|
drainPumpAlRes_2 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Reset drain pump AL"
|
|
::= { binaryObjects2 69 }
|
|
|
|
elHeatAlRes_2 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Reset electric heater AL"
|
|
::= { binaryObjects2 70 }
|
|
|
|
filterAlRes_2 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Reset dirty filter AL"
|
|
::= { binaryObjects2 71 }
|
|
|
|
dryCoolerAlRes_2 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Reset dry cooler AL"
|
|
::= { binaryObjects2 72 }
|
|
|
|
extHumidifAlRes_2 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Reset ext. humidifier AL"
|
|
::= { binaryObjects2 73 }
|
|
|
|
waterPumpAlRes_2 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Reset water pump AL"
|
|
::= { binaryObjects2 74 }
|
|
|
|
condUnitGAlRes_2 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Reset motocondenser AL"
|
|
::= { binaryObjects2 75 }
|
|
|
|
gasLeakAlRes_2 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Reset gas leak AL"
|
|
::= { binaryObjects2 76 }
|
|
|
|
powerSupAlRes_2 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Reset power fault AL"
|
|
::= { binaryObjects2 77 }
|
|
|
|
genSoftAlRes_2 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Reset generic soft AL"
|
|
::= { binaryObjects2 78 }
|
|
|
|
scalarsObjects2 OBJECT IDENTIFIER ::= { node2 2 }
|
|
|
|
confDI1Combo_2 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Configurable DI1 meaning"
|
|
::= { scalarsObjects2 1 }
|
|
|
|
confDI2Combo_2 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Configurable DI2 meaning"
|
|
::= { scalarsObjects2 2 }
|
|
|
|
confDI3Combo_2 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Configurable DI3 meaning"
|
|
::= { scalarsObjects2 3 }
|
|
|
|
confDI4Combo_2 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Configurable DI4 meaning"
|
|
::= { scalarsObjects2 4 }
|
|
|
|
confDI5Combo_2 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Configurable DI5 meaning"
|
|
::= { scalarsObjects2 5 }
|
|
|
|
confDO1Combo_2 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Configurable DO1 meaning"
|
|
::= { scalarsObjects2 6 }
|
|
|
|
confDO2Combo_2 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Configurable DO2 meaning"
|
|
::= { scalarsObjects2 7 }
|
|
|
|
confDO3Combo_2 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Configurable DO3 meaning"
|
|
::= { scalarsObjects2 8 }
|
|
|
|
confDO4Combo_2 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Configurable DO4 meaning"
|
|
::= { scalarsObjects2 9 }
|
|
|
|
confDO5Combo_2 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Configurable DO5 meaning"
|
|
::= { scalarsObjects2 10 }
|
|
|
|
returnTemp_2 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Return temperature"
|
|
::= { scalarsObjects2 11 }
|
|
|
|
returnTAvg_2 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Return temperature (AVG)"
|
|
::= { scalarsObjects2 12 }
|
|
|
|
supplyTemp_2 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Supply temperature"
|
|
::= { scalarsObjects2 13 }
|
|
|
|
supplyTAvg_2 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Supply temperature (AVG)"
|
|
::= { scalarsObjects2 14 }
|
|
|
|
tempDelta_2 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Temperature delta"
|
|
::= { scalarsObjects2 15 }
|
|
|
|
returnHumidity_2 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Return humidity"
|
|
::= { scalarsObjects2 16 }
|
|
|
|
returnHumAvg_2 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Return humidity (AVG)"
|
|
::= { scalarsObjects2 17 }
|
|
|
|
supplyHumidity_2 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Supply humidity"
|
|
::= { scalarsObjects2 18 }
|
|
|
|
supplyHumAvg_2 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Supply humidity (AVG)"
|
|
::= { scalarsObjects2 19 }
|
|
|
|
airFlow_2 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Air flow"
|
|
::= { scalarsObjects2 20 }
|
|
|
|
airPressure_2 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Air pressure"
|
|
::= { scalarsObjects2 22 }
|
|
|
|
airPressureAvg_2 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Air pressure (Average)"
|
|
::= { scalarsObjects2 23 }
|
|
|
|
netMod1Combo1_2 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Module 1 - Probe 1 status"
|
|
::= { scalarsObjects2 24 }
|
|
|
|
netMod1Probe1_2 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Module 1 - Probe 1 value"
|
|
::= { scalarsObjects2 25 }
|
|
|
|
netMod1Combo2_2 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Module 1 - Probe 2 status"
|
|
::= { scalarsObjects2 26 }
|
|
|
|
netMod1Probe2_2 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Module 1 - Probe 2 value"
|
|
::= { scalarsObjects2 27 }
|
|
|
|
netMod1Combo3_2 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Module 1 - Probe 3 status"
|
|
::= { scalarsObjects2 28 }
|
|
|
|
netMod1Probe3_2 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Module 1 - Probe 3 value"
|
|
::= { scalarsObjects2 29 }
|
|
|
|
netMod1Combo4_2 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Module 1 - Probe 4 status"
|
|
::= { scalarsObjects2 30 }
|
|
|
|
netMod1Probe4_2 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Module 1 - Probe 4 value"
|
|
::= { scalarsObjects2 31 }
|
|
|
|
netMod1Combo5_2 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Module 1 - Probe 5 status"
|
|
::= { scalarsObjects2 32 }
|
|
|
|
netMod1Probe5_2 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Module 1 - Probe 5 value"
|
|
::= { scalarsObjects2 33 }
|
|
|
|
netMod1Combo6_2 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Module 1 - Probe 6 status"
|
|
::= { scalarsObjects2 34 }
|
|
|
|
netMod1Probe6_2 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Module 1 - Probe 6 value"
|
|
::= { scalarsObjects2 35 }
|
|
|
|
netMod2Combo1_2 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Module 2 - Probe 1 status"
|
|
::= { scalarsObjects2 36 }
|
|
|
|
netMod2Probe1_2 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Module 2 - Probe 1 value"
|
|
::= { scalarsObjects2 37 }
|
|
|
|
netMod2Combo2_2 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Module 2 - Probe 2 status"
|
|
::= { scalarsObjects2 38 }
|
|
|
|
netMod2Probe2_2 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Module 2 - Probe 2 value"
|
|
::= { scalarsObjects2 39 }
|
|
|
|
netMod2Combo3_2 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Module 2 - Probe 3 status"
|
|
::= { scalarsObjects2 40 }
|
|
|
|
netMod2Probe3_2 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Module 2 - Probe 3 value"
|
|
::= { scalarsObjects2 41 }
|
|
|
|
netMod2Combo4_2 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Module 2 - Probe 4 status"
|
|
::= { scalarsObjects2 42 }
|
|
|
|
netMod2Probe4_2 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Module 2 - Probe 4 value"
|
|
::= { scalarsObjects2 43 }
|
|
|
|
netMod2Combo5_2 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Module 2 - Probe 5 status"
|
|
::= { scalarsObjects2 44 }
|
|
|
|
netMod2Probe5_2 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Module 2 - Probe 5 value"
|
|
::= { scalarsObjects2 45 }
|
|
|
|
netMod2Combo6_2 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Module 2 - Probe 6 status"
|
|
::= { scalarsObjects2 46 }
|
|
|
|
netMod2Probe6_2 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Module 2 - Probe 6 value"
|
|
::= { scalarsObjects2 47 }
|
|
|
|
netMod3Combo1_2 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Module 3 - Probe 1 status"
|
|
::= { scalarsObjects2 48 }
|
|
|
|
netMod3Probe1_2 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Module 3 - Probe 1 value"
|
|
::= { scalarsObjects2 49 }
|
|
|
|
netMod3Combo2_2 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Module 3 - Probe 2 status"
|
|
::= { scalarsObjects2 50 }
|
|
|
|
netMod3Probe2_2 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Module 3 - Probe 2 value"
|
|
::= { scalarsObjects2 51 }
|
|
|
|
netMod3Combo3_2 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Module 3 - Probe 3 status"
|
|
::= { scalarsObjects2 52 }
|
|
|
|
netMod3Probe3_2 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Module 3 - Probe 3 value"
|
|
::= { scalarsObjects2 53 }
|
|
|
|
netMod3Combo4_2 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Module 3 - Probe 4 status"
|
|
::= { scalarsObjects2 54 }
|
|
|
|
netMod3Probe4_2 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Module 3 - Probe 4 value"
|
|
::= { scalarsObjects2 55 }
|
|
|
|
netMod3Combo5_2 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Module 3 - Probe 5 status"
|
|
::= { scalarsObjects2 56 }
|
|
|
|
netMod3Probe5_2 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Module 3 - Probe 5 value"
|
|
::= { scalarsObjects2 57 }
|
|
|
|
netMod3Combo6_2 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Module 3 - Probe 6 status"
|
|
::= { scalarsObjects2 58 }
|
|
|
|
netMod3Probe6_2 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Module 3 - Probe 6 value"
|
|
::= { scalarsObjects2 59 }
|
|
|
|
avgModTemp_2 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Modules temperatures AVG"
|
|
::= { scalarsObjects2 60 }
|
|
|
|
avgModHumi_2 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Modules humidity AVG"
|
|
::= { scalarsObjects2 61 }
|
|
|
|
avgModPress_2 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Modules pressure AVG"
|
|
::= { scalarsObjects2 62 }
|
|
|
|
dryCoolerAO_2 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Supply Fan/Dry cooler"
|
|
::= { scalarsObjects2 63 }
|
|
|
|
coolingAO_2 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Cooling valve/FC/Inverter"
|
|
::= { scalarsObjects2 64 }
|
|
|
|
heatingAO_2 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Heating valve/Heater"
|
|
::= { scalarsObjects2 65 }
|
|
|
|
twoSources2AO_2 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "TS cooling valve 2"
|
|
::= { scalarsObjects2 66 }
|
|
|
|
condenser1AO_2 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Condenser 1"
|
|
::= { scalarsObjects2 67 }
|
|
|
|
cond2HumidifAO_2 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Condenser 2/Humidifier"
|
|
::= { scalarsObjects2 68 }
|
|
|
|
unitStatus_2 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Unit status"
|
|
::= { scalarsObjects2 69 }
|
|
|
|
fanSpeed_2 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Fan speed"
|
|
::= { scalarsObjects2 70 }
|
|
|
|
fan1Actspeed_2 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Fan 1 speed"
|
|
::= { scalarsObjects2 71 }
|
|
|
|
fan1ActRPM_2 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Fan 1 speed RPM"
|
|
::= { scalarsObjects2 72 }
|
|
|
|
fan1Cur_2 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Fan 1 current"
|
|
::= { scalarsObjects2 73 }
|
|
|
|
fan1Power_2 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Fan 1 power"
|
|
::= { scalarsObjects2 74 }
|
|
|
|
fan2Actspeed_2 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Fan 2 speed"
|
|
::= { scalarsObjects2 75 }
|
|
|
|
fan2ActRPM_2 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Fan 2 speed RPM"
|
|
::= { scalarsObjects2 76 }
|
|
|
|
fan2Cur_2 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Fan 2 current"
|
|
::= { scalarsObjects2 77 }
|
|
|
|
fan2Power_2 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Fan 2 power"
|
|
::= { scalarsObjects2 78 }
|
|
|
|
fan3Actspeed_2 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Fan 3 speed"
|
|
::= { scalarsObjects2 79 }
|
|
|
|
fan3ActRPM_2 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Fan 3 speed RPM"
|
|
::= { scalarsObjects2 80 }
|
|
|
|
fan3Cur_2 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Fan 3 current"
|
|
::= { scalarsObjects2 81 }
|
|
|
|
fan3Power_2 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Fan 3 power"
|
|
::= { scalarsObjects2 82 }
|
|
|
|
fan4Actspeed_2 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Fan 4 speed"
|
|
::= { scalarsObjects2 83 }
|
|
|
|
fan4ActRPM_2 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Fan 4 speed RPM"
|
|
::= { scalarsObjects2 84 }
|
|
|
|
fan4Cur_2 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Fan 4 current"
|
|
::= { scalarsObjects2 85 }
|
|
|
|
fan4Power_2 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Fan 4 power"
|
|
::= { scalarsObjects2 86 }
|
|
|
|
fan5Actspeed_2 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Fan 5 speed"
|
|
::= { scalarsObjects2 87 }
|
|
|
|
fan5ActRPM_2 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Fan 5 speed RPM"
|
|
::= { scalarsObjects2 88 }
|
|
|
|
fan5Cur_2 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Fan 5 current"
|
|
::= { scalarsObjects2 89 }
|
|
|
|
fan5Power_2 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Fan 5 power"
|
|
::= { scalarsObjects2 90 }
|
|
|
|
fan6Actspeed_2 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Fan 6 speed"
|
|
::= { scalarsObjects2 91 }
|
|
|
|
fan6ActRPM_2 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Fan 6 speed RPM"
|
|
::= { scalarsObjects2 92 }
|
|
|
|
fan6Cur_2 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Fan 6 current"
|
|
::= { scalarsObjects2 93 }
|
|
|
|
fan6Power_2 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Fan 6 power"
|
|
::= { scalarsObjects2 94 }
|
|
|
|
fan7Actspeed_2 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Fan 7 speed"
|
|
::= { scalarsObjects2 95 }
|
|
|
|
fan7ActRPM_2 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Fan 7 speed RPM"
|
|
::= { scalarsObjects2 96 }
|
|
|
|
fan7Cur_2 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Fan 7 current"
|
|
::= { scalarsObjects2 97 }
|
|
|
|
fan7Power_2 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Fan 7 power"
|
|
::= { scalarsObjects2 98 }
|
|
|
|
fan8Actspeed_2 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Fan 8 speed"
|
|
::= { scalarsObjects2 99 }
|
|
|
|
fan8ActRPM_2 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Fan 8 speed RPM"
|
|
::= { scalarsObjects2 100 }
|
|
|
|
fan8Cur_2 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Fan 8 current"
|
|
::= { scalarsObjects2 101 }
|
|
|
|
fan8Power_2 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Fan 8 power"
|
|
::= { scalarsObjects2 102 }
|
|
|
|
fan9Actspeed_2 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Fan 9 speed"
|
|
::= { scalarsObjects2 103 }
|
|
|
|
fan9ActRPM_2 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Fan 9 speed RPM"
|
|
::= { scalarsObjects2 104 }
|
|
|
|
fan9Cur_2 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Fan 9 current"
|
|
::= { scalarsObjects2 105 }
|
|
|
|
fan9Power_2 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Fan 9 power"
|
|
::= { scalarsObjects2 106 }
|
|
|
|
fan10Actspeed_2 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Fan 10 speed"
|
|
::= { scalarsObjects2 107 }
|
|
|
|
fan10ActRPM_2 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Fan 10 speed RPM"
|
|
::= { scalarsObjects2 108 }
|
|
|
|
fan10Cur_2 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Fan 10 current"
|
|
::= { scalarsObjects2 109 }
|
|
|
|
fan10Power_2 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Fan 10 power"
|
|
::= { scalarsObjects2 110 }
|
|
|
|
diffFilterPres_2 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Dirty filter pressure"
|
|
::= { scalarsObjects2 111 }
|
|
|
|
coolingRequest_2 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Cooling request"
|
|
::= { scalarsObjects2 112 }
|
|
|
|
heatingRequest_2 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Heating request"
|
|
::= { scalarsObjects2 113 }
|
|
|
|
dehumidRequest_2 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Dehumidification request"
|
|
::= { scalarsObjects2 114 }
|
|
|
|
humidifRequest_2 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Humidification request"
|
|
::= { scalarsObjects2 115 }
|
|
|
|
tempFcTs_2 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "FC/TS temperature"
|
|
::= { scalarsObjects2 116 }
|
|
|
|
fCTSStatus_2 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "FC/TS status"
|
|
::= { scalarsObjects2 117 }
|
|
|
|
fCRequest_2 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Free cooling request"
|
|
::= { scalarsObjects2 118 }
|
|
|
|
activeComp_2 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Active compressor"
|
|
::= { scalarsObjects2 119 }
|
|
|
|
comp1Sts_2 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Compressor 1 Status"
|
|
::= { scalarsObjects2 120 }
|
|
|
|
comp2Sts_2 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Compressor 2 Status"
|
|
::= { scalarsObjects2 121 }
|
|
|
|
invComprReq_2 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Inverter compressor request"
|
|
::= { scalarsObjects2 122 }
|
|
|
|
invCompHz_2 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Inverter frequency"
|
|
::= { scalarsObjects2 123 }
|
|
|
|
invCompPower_2 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Inverter power input"
|
|
::= { scalarsObjects2 124 }
|
|
|
|
invCompCurrent_2 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Inverter absorbed current"
|
|
::= { scalarsObjects2 125 }
|
|
|
|
c1EvapPres_2 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "C1 evaporation pressure"
|
|
::= { scalarsObjects2 126 }
|
|
|
|
c1EvapTemp_2 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "C1 evaporation temperature"
|
|
::= { scalarsObjects2 127 }
|
|
|
|
c1SuctionTemp_2 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "C1 suction temperature"
|
|
::= { scalarsObjects2 128 }
|
|
|
|
c1Superheat_2 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "C1 super-heating"
|
|
::= { scalarsObjects2 129 }
|
|
|
|
c1CompRatio_2 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "C1 compression ratio"
|
|
::= { scalarsObjects2 130 }
|
|
|
|
c1DischTemp_2 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "C1 discharge temperature"
|
|
::= { scalarsObjects2 131 }
|
|
|
|
c1CondPress_2 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "C1 condensation pressure"
|
|
::= { scalarsObjects2 132 }
|
|
|
|
c1CondTemp_2 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "C1 condensation temperature"
|
|
::= { scalarsObjects2 133 }
|
|
|
|
c1Desuperheat_2 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "C1 de-superheating"
|
|
::= { scalarsObjects2 134 }
|
|
|
|
c1LiquidTemp_2 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "C1 liquid temperature"
|
|
::= { scalarsObjects2 135 }
|
|
|
|
c1Subcooling_2 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "C1 sub-cooling"
|
|
::= { scalarsObjects2 136 }
|
|
|
|
eEV1SHSet_2 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "EEV1 super-heating set-point"
|
|
::= { scalarsObjects2 137 }
|
|
|
|
eEV1Position_2 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "EEV1 position"
|
|
::= { scalarsObjects2 138 }
|
|
|
|
eEV1Status_2 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "EEV1 working status"
|
|
::= { scalarsObjects2 139 }
|
|
|
|
cond1ActualSet_2 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Condenser 1 current set"
|
|
::= { scalarsObjects2 140 }
|
|
|
|
cond1Req_2 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Condenser 1 request"
|
|
::= { scalarsObjects2 141 }
|
|
|
|
c2EvapPres_2 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "C2 evaporation pressure"
|
|
::= { scalarsObjects2 142 }
|
|
|
|
c2EvapTemp_2 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "C2 evaporation temperature"
|
|
::= { scalarsObjects2 143 }
|
|
|
|
c2SuctionTemp_2 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "C2 suction temperature"
|
|
::= { scalarsObjects2 144 }
|
|
|
|
c2Superheat_2 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "C2 super-heating"
|
|
::= { scalarsObjects2 145 }
|
|
|
|
c2CompRatio_2 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "C2 compression ratio"
|
|
::= { scalarsObjects2 146 }
|
|
|
|
c2DischTemp_2 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "C2 discharge temperature"
|
|
::= { scalarsObjects2 147 }
|
|
|
|
c2CondPress_2 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "C2 condensation pressure"
|
|
::= { scalarsObjects2 148 }
|
|
|
|
c2CondTemp_2 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "C2 condensation temperature"
|
|
::= { scalarsObjects2 149 }
|
|
|
|
c2Desuperheat_2 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "C2 de-superheating"
|
|
::= { scalarsObjects2 150 }
|
|
|
|
c2LiquidTemp_2 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "C2 liquid temperature"
|
|
::= { scalarsObjects2 151 }
|
|
|
|
c2Subcooling_2 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "C2 sub-cooling"
|
|
::= { scalarsObjects2 152 }
|
|
|
|
eEV2SHSet_2 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "EEV2 superheat set-point"
|
|
::= { scalarsObjects2 153 }
|
|
|
|
eEV2Position_2 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "EEV2 position"
|
|
::= { scalarsObjects2 154 }
|
|
|
|
eEV2Status_2 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "EEV2 working status"
|
|
::= { scalarsObjects2 155 }
|
|
|
|
cond2ActualSet_2 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Condenser 2 current set"
|
|
::= { scalarsObjects2 156 }
|
|
|
|
cond2Req_2 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Condenser 2 request"
|
|
::= { scalarsObjects2 157 }
|
|
|
|
waterINTemp1_2 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Water IN temperature 1"
|
|
::= { scalarsObjects2 158 }
|
|
|
|
waterOUTTemp1_2 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Water OUT temperature 1"
|
|
::= { scalarsObjects2 159 }
|
|
|
|
waterDT1_2 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Water temperature delta 1"
|
|
::= { scalarsObjects2 160 }
|
|
|
|
waterFlow1_2 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Water flow rate 1"
|
|
::= { scalarsObjects2 161 }
|
|
|
|
actWatFlowSet1_2 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Actual water flow set 1"
|
|
::= { scalarsObjects2 162 }
|
|
|
|
waterCoolCap1_2 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Water cooling capacity 1"
|
|
::= { scalarsObjects2 163 }
|
|
|
|
eER1_2 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "EER 1"
|
|
::= { scalarsObjects2 164 }
|
|
|
|
valve1Position_2 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Water valve 1 position"
|
|
::= { scalarsObjects2 165 }
|
|
|
|
waterINTemp2_2 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Water IN temperature 2"
|
|
::= { scalarsObjects2 166 }
|
|
|
|
waterOUTTemp2_2 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Water OUT temperature 2"
|
|
::= { scalarsObjects2 167 }
|
|
|
|
waterDT2_2 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Water temperature delta 2"
|
|
::= { scalarsObjects2 168 }
|
|
|
|
waterFlow2_2 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Water flow rate 2"
|
|
::= { scalarsObjects2 169 }
|
|
|
|
actWatFlowSet2_2 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Actual water flow set 2"
|
|
::= { scalarsObjects2 170 }
|
|
|
|
waterCoolCap2_2 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Water cooling capacity 2"
|
|
::= { scalarsObjects2 171 }
|
|
|
|
eER2_2 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "EER 2"
|
|
::= { scalarsObjects2 172 }
|
|
|
|
valve2Position_2 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Water valve 2 position"
|
|
::= { scalarsObjects2 173 }
|
|
|
|
humSteamProd_2 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Current steam production"
|
|
::= { scalarsObjects2 174 }
|
|
|
|
humWaterConduct_2 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Humidifier conductivity"
|
|
::= { scalarsObjects2 175 }
|
|
|
|
humCurrent_2 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Humidifier abs. Current"
|
|
::= { scalarsObjects2 176 }
|
|
|
|
humWorkingMode_2 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Humidifier operating mode"
|
|
::= { scalarsObjects2 177 }
|
|
|
|
humWorkStatus_2 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Humidifier operating status"
|
|
::= { scalarsObjects2 178 }
|
|
|
|
heaterReq_2 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Electric heater request"
|
|
::= { scalarsObjects2 179 }
|
|
|
|
heaterActiveStg_2 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Number of active stages"
|
|
::= { scalarsObjects2 180 }
|
|
|
|
elHeaterPower_2 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Electric heater power"
|
|
::= { scalarsObjects2 181 }
|
|
|
|
heatValveReq_2 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Hot water valve request"
|
|
::= { scalarsObjects2 182 }
|
|
|
|
dryCoolerActSet_2 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Current dry cooler set"
|
|
::= { scalarsObjects2 183 }
|
|
|
|
dryCoolerReq_2 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Dry cooler request"
|
|
::= { scalarsObjects2 184 }
|
|
|
|
unitWH_2 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Unit working hours"
|
|
::= { scalarsObjects2 185 }
|
|
|
|
c1WH_2 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Compressor1 working hours"
|
|
::= { scalarsObjects2 186 }
|
|
|
|
c1Startup_2 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Compressor 1 startups"
|
|
::= { scalarsObjects2 187 }
|
|
|
|
c2WH_2 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Compressor2 working hours"
|
|
::= { scalarsObjects2 188 }
|
|
|
|
c2Startup_2 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Compressor 2 startups"
|
|
::= { scalarsObjects2 189 }
|
|
|
|
coolValveWH_2 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Cooling working hours"
|
|
::= { scalarsObjects2 190 }
|
|
|
|
heatingWH_2 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Heating working hours"
|
|
::= { scalarsObjects2 191 }
|
|
|
|
humidifWH_2 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Humidifier working hours"
|
|
::= { scalarsObjects2 192 }
|
|
|
|
freeCoolWH_2 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "FC working hours"
|
|
::= { scalarsObjects2 193 }
|
|
|
|
dryCoolerWH_2 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Dry cooler working hours"
|
|
::= { scalarsObjects2 194 }
|
|
|
|
cond1WH_2 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Condenser1 working hours"
|
|
::= { scalarsObjects2 195 }
|
|
|
|
cond2WH_2 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Condenser2 working hours"
|
|
::= { scalarsObjects2 196 }
|
|
|
|
tempSetpoint_2 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Temperature set-point"
|
|
::= { scalarsObjects2 197 }
|
|
|
|
humSetpoint_2 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Humidity set-point"
|
|
::= { scalarsObjects2 198 }
|
|
|
|
airFlowSetpoint_2 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Air flow set-point"
|
|
::= { scalarsObjects2 199 }
|
|
|
|
airPresSetpoint_2 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Air pressure set-point"
|
|
::= { scalarsObjects2 200 }
|
|
|
|
airDTSetpoint_2 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Air temperature delta set"
|
|
::= { scalarsObjects2 201 }
|
|
|
|
tempControlSel_2 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Regulation sensor"
|
|
::= { scalarsObjects2 202 }
|
|
|
|
tempControlType_2 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Regulation type"
|
|
::= { scalarsObjects2 203 }
|
|
|
|
tPropBand_2 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Proportional Band"
|
|
::= { scalarsObjects2 204 }
|
|
|
|
tIntegralTime_2 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Integration time"
|
|
::= { scalarsObjects2 205 }
|
|
|
|
tDerivativeTime_2 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Derivative time"
|
|
::= { scalarsObjects2 206 }
|
|
|
|
highTAlOffset_2 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "High temperature offset"
|
|
::= { scalarsObjects2 207 }
|
|
|
|
lowTAlOffset_2 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Low temperature offset"
|
|
::= { scalarsObjects2 208 }
|
|
|
|
highLimitTThr_2 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "High limit temp. thresh."
|
|
::= { scalarsObjects2 209 }
|
|
|
|
highLimitTMng_2 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "High limit temp. managem."
|
|
::= { scalarsObjects2 210 }
|
|
|
|
lowLimitTThr_2 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Low limit temp.thresh."
|
|
::= { scalarsObjects2 211 }
|
|
|
|
lowLimitTMng_2 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Low limit temp. managem."
|
|
::= { scalarsObjects2 212 }
|
|
|
|
dehumPropBand_2 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Dehumid. proportion. band"
|
|
::= { scalarsObjects2 213 }
|
|
|
|
humPropBand_2 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Humid. proportion. band"
|
|
::= { scalarsObjects2 214 }
|
|
|
|
hRetHAlOffset_2 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "High humidity offset"
|
|
::= { scalarsObjects2 215 }
|
|
|
|
lRetHAlOffset_2 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Low humidity offset"
|
|
::= { scalarsObjects2 216 }
|
|
|
|
highSupHumThr_2 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "High supp. humidity thr."
|
|
::= { scalarsObjects2 217 }
|
|
|
|
lowSupHumThr_2 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Low supp. humidity thr."
|
|
::= { scalarsObjects2 218 }
|
|
|
|
fCDelta_2 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Free cooling delta"
|
|
::= { scalarsObjects2 219 }
|
|
|
|
tSWaterSet_2 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Two sources set-point"
|
|
::= { scalarsObjects2 220 }
|
|
|
|
tSWaterPropBand_2 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Two sources band"
|
|
::= { scalarsObjects2 221 }
|
|
|
|
tSAirTempSet_2 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "TS room temp. Exch. set"
|
|
::= { scalarsObjects2 222 }
|
|
|
|
condSetpoint_2 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Condensation set-point"
|
|
::= { scalarsObjects2 223 }
|
|
|
|
condPropoBand_2 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Condensation band"
|
|
::= { scalarsObjects2 224 }
|
|
|
|
condSetIncrease_2 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Condensation set increase"
|
|
::= { scalarsObjects2 225 }
|
|
|
|
maxCondSetpoint_2 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Maximum condensation set"
|
|
::= { scalarsObjects2 226 }
|
|
|
|
dryCoolerSet_2 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Dry cooler set-point"
|
|
::= { scalarsObjects2 227 }
|
|
|
|
dryCoolPropBand_2 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Dry cooler band"
|
|
::= { scalarsObjects2 228 }
|
|
|
|
dryCoolSetIncr_2 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Dry Cooler set increase"
|
|
::= { scalarsObjects2 229 }
|
|
|
|
maxDryCoolerSet_2 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Maximum dry Cooler set"
|
|
::= { scalarsObjects2 230 }
|
|
|
|
dirtyFiltSet_2 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Dirty filter set-point"
|
|
::= { scalarsObjects2 231 }
|
|
|
|
dirtyFiltDiff_2 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Dirty filter differential"
|
|
::= { scalarsObjects2 232 }
|
|
|
|
invCompAlCode1_2 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "DC Inverter alarm code 1"
|
|
::= { scalarsObjects2 233 }
|
|
|
|
invCompAlCode2_2 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "DC Inverter alarm code 2"
|
|
::= { scalarsObjects2 234 }
|
|
|
|
invCompAlCode3_2 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "DC Inverter alarm code 3"
|
|
::= { scalarsObjects2 235 }
|
|
|
|
invCompAlCode4_2 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "DC Inverter alarm code 4"
|
|
::= { scalarsObjects2 236 }
|
|
|
|
invCompAlCode5_2 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "DC Inverter alarm code 5"
|
|
::= { scalarsObjects2 237 }
|
|
|
|
alarms2 OBJECT IDENTIFIER ::= { node2 3 }
|
|
|
|
generalAl_2 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "General alarams"
|
|
::= { alarms2 1 }
|
|
|
|
notCriticAl_2 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Not critical alarms"
|
|
::= { alarms2 2 }
|
|
|
|
criticalAl_2 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Critical alarms"
|
|
::= { alarms2 3 }
|
|
|
|
fansAl_2 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Fans alarms"
|
|
::= { alarms2 4 }
|
|
|
|
compAl_2 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Compressors alarms"
|
|
::= { alarms2 5 }
|
|
|
|
tempAl_2 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Temperature alarms"
|
|
::= { alarms2 6 }
|
|
|
|
humidityAl_2 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Humidity alarms"
|
|
::= { alarms2 7 }
|
|
|
|
damperAl_2 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Damper status alarm"
|
|
::= { alarms2 8 }
|
|
|
|
fireSmokeAl_2 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Fire/Smoke alarm"
|
|
::= { alarms2 9 }
|
|
|
|
gSeriousAl_2 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Critical generic alarm"
|
|
::= { alarms2 10 }
|
|
|
|
fansGenAl_2 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "General supply fans alarm"
|
|
::= { alarms2 11 }
|
|
|
|
f1GeneralAl_2 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Fan general alarm 1"
|
|
::= { alarms2 12 }
|
|
|
|
f1PowerAl_2 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Phase failure/undervolt.1"
|
|
::= { alarms2 13 }
|
|
|
|
f1CommAl_2 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Communication 1"
|
|
::= { alarms2 14 }
|
|
|
|
f1HiTempAl_2 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Power mod overheated 1"
|
|
::= { alarms2 15 }
|
|
|
|
f1NetComAl_2 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Master/Slave com. 1"
|
|
::= { alarms2 16 }
|
|
|
|
f1InvRegAl_2 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Regulation module 1"
|
|
::= { alarms2 17 }
|
|
|
|
f1HiMotTAl_2 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Motor overheated 1"
|
|
::= { alarms2 18 }
|
|
|
|
f1HallSenAl_2 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Hall sensor error 1"
|
|
::= { alarms2 19 }
|
|
|
|
f1OverlAl_2 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Locked motor 1"
|
|
::= { alarms2 20 }
|
|
|
|
f1LowDCAl_2 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Low DC 1"
|
|
::= { alarms2 21 }
|
|
|
|
f2GeneralAl_2 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Fan general alarm 2"
|
|
::= { alarms2 22 }
|
|
|
|
f2PowerAl_2 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Phase failure/undervolt.2"
|
|
::= { alarms2 23 }
|
|
|
|
f2CommAl_2 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Communication 2"
|
|
::= { alarms2 24 }
|
|
|
|
f2HiTempAl_2 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Power mod overheated 2"
|
|
::= { alarms2 25 }
|
|
|
|
f2NetComAl_2 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Master/Slave com. 2"
|
|
::= { alarms2 26 }
|
|
|
|
f2InvRegAl_2 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Regulation module 2"
|
|
::= { alarms2 27 }
|
|
|
|
f2HiMotTAl_2 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Motor overheated 2"
|
|
::= { alarms2 28 }
|
|
|
|
f2HallSenAl_2 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Hall sensor error 2"
|
|
::= { alarms2 29 }
|
|
|
|
f2OverlAl_2 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Locked motor 2"
|
|
::= { alarms2 30 }
|
|
|
|
f2LowDCAl_2 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Low DC 2"
|
|
::= { alarms2 31 }
|
|
|
|
f3GeneralAl_2 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Fan general alarm 3"
|
|
::= { alarms2 32 }
|
|
|
|
f3PowerAl_2 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Phase failure/undervolt.3"
|
|
::= { alarms2 33 }
|
|
|
|
f3CommAl_2 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Communication 3"
|
|
::= { alarms2 34 }
|
|
|
|
f3HiTempAl_2 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Power mod overheated 3"
|
|
::= { alarms2 35 }
|
|
|
|
f3NetComAl_2 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Master/Slave com. 3"
|
|
::= { alarms2 36 }
|
|
|
|
f3InvRegAl_2 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Regulation module 3"
|
|
::= { alarms2 37 }
|
|
|
|
f3HiMotTAl_2 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Motor overheated 3"
|
|
::= { alarms2 38 }
|
|
|
|
f3HallSenAl_2 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Hall sensor error 3"
|
|
::= { alarms2 39 }
|
|
|
|
f3OverlAl_2 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Locked motor 3"
|
|
::= { alarms2 40 }
|
|
|
|
f3LowDCAl_2 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Low DC 3"
|
|
::= { alarms2 41 }
|
|
|
|
f4GeneralAl_2 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Fan general alarm 4"
|
|
::= { alarms2 42 }
|
|
|
|
f4PowerAl_2 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Phase failure/undervolt.4"
|
|
::= { alarms2 43 }
|
|
|
|
f4CommAl_2 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Communication 4"
|
|
::= { alarms2 44 }
|
|
|
|
f4HiTempAl_2 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Power mod overheated 4"
|
|
::= { alarms2 45 }
|
|
|
|
f4NetComAl_2 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Master/Slave com. 4"
|
|
::= { alarms2 46 }
|
|
|
|
f4InvRegAl_2 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Regulation module 4"
|
|
::= { alarms2 47 }
|
|
|
|
f4HiMotTAl_2 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Motor overheated 4"
|
|
::= { alarms2 48 }
|
|
|
|
f4HallSenAl_2 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Hall sensor error 4"
|
|
::= { alarms2 49 }
|
|
|
|
f4OverlAl_2 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Locked motor 4"
|
|
::= { alarms2 50 }
|
|
|
|
f4LowDCAl_2 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Low DC 4"
|
|
::= { alarms2 51 }
|
|
|
|
f5GeneralAl_2 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Fan general alarm 5"
|
|
::= { alarms2 52 }
|
|
|
|
f5PowerAl_2 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Phase failure/undervolt.5"
|
|
::= { alarms2 53 }
|
|
|
|
f5CommAl_2 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Communication 5"
|
|
::= { alarms2 54 }
|
|
|
|
f5HiTempAl_2 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Power mod overheated 5"
|
|
::= { alarms2 55 }
|
|
|
|
f5NetComAl_2 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Master/Slave com. 5"
|
|
::= { alarms2 56 }
|
|
|
|
f5InvRegAl_2 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Regulation module 5"
|
|
::= { alarms2 57 }
|
|
|
|
f5HiMotTAl_2 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Motor overheated 5"
|
|
::= { alarms2 58 }
|
|
|
|
f5HallSenAl_2 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Hall sensor error 5"
|
|
::= { alarms2 59 }
|
|
|
|
f5OverlAl_2 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Locked motor 5"
|
|
::= { alarms2 60 }
|
|
|
|
f5LowDCAl_2 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Low DC 5"
|
|
::= { alarms2 61 }
|
|
|
|
f6GeneralAl_2 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Fan general alarm 6"
|
|
::= { alarms2 62 }
|
|
|
|
f6PowerAl_2 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Phase failure/undervolt.6"
|
|
::= { alarms2 63 }
|
|
|
|
f6CommAl_2 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Communication 6"
|
|
::= { alarms2 64 }
|
|
|
|
f6HiTempAl_2 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Power mod overheated 6"
|
|
::= { alarms2 65 }
|
|
|
|
f6NetComAl_2 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Master/Slave com. 6"
|
|
::= { alarms2 66 }
|
|
|
|
f6InvRegAl_2 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Regulation module 6"
|
|
::= { alarms2 67 }
|
|
|
|
f6HiMotTAl_2 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Motor overheated 6"
|
|
::= { alarms2 68 }
|
|
|
|
f6HallSenAl_2 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Hall sensor error 6"
|
|
::= { alarms2 69 }
|
|
|
|
f6OverlAl_2 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Locked motor 6"
|
|
::= { alarms2 70 }
|
|
|
|
f6LowDCAl_2 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Low DC 6"
|
|
::= { alarms2 71 }
|
|
|
|
f7GeneralAl_2 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Fan general alarm 7"
|
|
::= { alarms2 72 }
|
|
|
|
f7PowerAl_2 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Phase failure/undervolt.7"
|
|
::= { alarms2 73 }
|
|
|
|
f7CommAl_2 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Communication 7"
|
|
::= { alarms2 74 }
|
|
|
|
f7HiTempAl_2 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Power mod overheated 7"
|
|
::= { alarms2 75 }
|
|
|
|
f7NetComAl_2 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Master/Slave com. 7"
|
|
::= { alarms2 76 }
|
|
|
|
f7InvRegAl_2 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Regulation module 7"
|
|
::= { alarms2 77 }
|
|
|
|
f7HiMotTAl_2 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Motor overheated 7"
|
|
::= { alarms2 78 }
|
|
|
|
f7HallSenAl_2 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Hall sensor error 7"
|
|
::= { alarms2 79 }
|
|
|
|
f7OverlAl_2 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Locked motor 7"
|
|
::= { alarms2 80 }
|
|
|
|
f7LowDCAl_2 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Low DC 7"
|
|
::= { alarms2 81 }
|
|
|
|
f8GeneralAl_2 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Fan general alarm 8"
|
|
::= { alarms2 82 }
|
|
|
|
f8PowerAl_2 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Phase failure/undervolt.8"
|
|
::= { alarms2 83 }
|
|
|
|
f8CommAl_2 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Communication 8"
|
|
::= { alarms2 84 }
|
|
|
|
f8HiTempAl_2 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Power mod overheated 8"
|
|
::= { alarms2 85 }
|
|
|
|
f8NetComAl_2 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Master/Slave com. 8"
|
|
::= { alarms2 86 }
|
|
|
|
f8InvRegAl_2 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Regulation module 8"
|
|
::= { alarms2 87 }
|
|
|
|
f8HiMotTAl_2 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Motor overheated 8"
|
|
::= { alarms2 88 }
|
|
|
|
f8HallSenAl_2 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Hall sensor error 8"
|
|
::= { alarms2 89 }
|
|
|
|
f8OverlAl_2 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Locked motor 8"
|
|
::= { alarms2 90 }
|
|
|
|
f8LowDCAl_2 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Low DC 8"
|
|
::= { alarms2 91 }
|
|
|
|
f9GeneralAl_2 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Fan general alarm 9"
|
|
::= { alarms2 92 }
|
|
|
|
f9PowerAl_2 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Phase failure/undervolt.9"
|
|
::= { alarms2 93 }
|
|
|
|
f9CommAl_2 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Communication 9"
|
|
::= { alarms2 94 }
|
|
|
|
f9HiTempAl_2 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Power mod overheated 9"
|
|
::= { alarms2 95 }
|
|
|
|
f9NetComAl_2 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Master/Slave com. 9"
|
|
::= { alarms2 96 }
|
|
|
|
f9InvRegAl_2 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Regulation module 9"
|
|
::= { alarms2 97 }
|
|
|
|
f9HiMotTAl_2 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Motor overheated 9"
|
|
::= { alarms2 98 }
|
|
|
|
f9HallSenAl_2 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Hall sensor error 9"
|
|
::= { alarms2 99 }
|
|
|
|
f9OverlAl_2 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Locked motor 9"
|
|
::= { alarms2 100 }
|
|
|
|
f9LowDCAl_2 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Low DC 9"
|
|
::= { alarms2 101 }
|
|
|
|
f10GenlAl_2 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Fan general alarm 10"
|
|
::= { alarms2 102 }
|
|
|
|
f10PowerAl_2 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Phase failure/undervolt.10"
|
|
::= { alarms2 103 }
|
|
|
|
f10CommAl_2 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Communication 10"
|
|
::= { alarms2 104 }
|
|
|
|
f10HiTempAl_2 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Power mod overheated 10"
|
|
::= { alarms2 105 }
|
|
|
|
f10NetComAl_2 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Master/Slave com. 10"
|
|
::= { alarms2 106 }
|
|
|
|
f10InvRegAl_2 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Regulation module 10"
|
|
::= { alarms2 107 }
|
|
|
|
f10HiMotTAl_2 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Motor overheated 10"
|
|
::= { alarms2 108 }
|
|
|
|
f10HallSAl_2 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Hall sensor error 10"
|
|
::= { alarms2 109 }
|
|
|
|
f10OverlAl_2 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Locked motor 10"
|
|
::= { alarms2 110 }
|
|
|
|
f10LowDCAl_2 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Low DC 10"
|
|
::= { alarms2 111 }
|
|
|
|
retTempPbAl_2 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Return temperature probe"
|
|
::= { alarms2 112 }
|
|
|
|
supTempPrAl_2 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Supply temperature probe"
|
|
::= { alarms2 113 }
|
|
|
|
retHumPrAl_2 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Return humidity probe"
|
|
::= { alarms2 114 }
|
|
|
|
supHumPrAl_2 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Supply humidity probe"
|
|
::= { alarms2 115 }
|
|
|
|
airPrSensAl_2 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Air diff.pressure probe"
|
|
::= { alarms2 116 }
|
|
|
|
watIN1PrAl_2 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Water temp. IN1 probe"
|
|
::= { alarms2 117 }
|
|
|
|
watOUT1PrAl_2 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Water temp. OUT1 probe"
|
|
::= { alarms2 118 }
|
|
|
|
watIN2PrAl_2 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Water temp. IN2 probe"
|
|
::= { alarms2 119 }
|
|
|
|
watOUT2PrAl_2 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Water temp. OUT2 probe"
|
|
::= { alarms2 120 }
|
|
|
|
watFlw1PrAl_2 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Water flow1/T.liquid1 pr."
|
|
::= { alarms2 121 }
|
|
|
|
watFlw2PrAl_2 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Water flow2/T.liquid2 pr."
|
|
::= { alarms2 122 }
|
|
|
|
dFPSGenAl_2 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Filter diff.press. probe"
|
|
::= { alarms2 123 }
|
|
|
|
dFPSBrokAl_2 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Breakdown alarm"
|
|
::= { alarms2 124 }
|
|
|
|
dFPSCablAl_2 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Wiring alarm"
|
|
::= { alarms2 125 }
|
|
|
|
dFPSRangeAl_2 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Pressure range alarm"
|
|
::= { alarms2 126 }
|
|
|
|
dFPSADCAl_2 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "ADC overload alarm"
|
|
::= { alarms2 127 }
|
|
|
|
dFPSSetAl_2 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Calibration alarm"
|
|
::= { alarms2 128 }
|
|
|
|
dFPSDCOAl_2 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "DCO alarm"
|
|
::= { alarms2 129 }
|
|
|
|
dFPSWatdAl_2 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Watchdog alarm"
|
|
::= { alarms2 130 }
|
|
|
|
dFPSCommAl_2 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Communication alarm"
|
|
::= { alarms2 131 }
|
|
|
|
invC1GenAl_2 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "DC inverter general alarm"
|
|
::= { alarms2 132 }
|
|
|
|
invC1CommAl_2 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Inverter communication"
|
|
::= { alarms2 133 }
|
|
|
|
c1ThermAl_2 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "C1 Thermal alarm"
|
|
::= { alarms2 134 }
|
|
|
|
c1HighPresAl_2 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "C1 High pressure alarm"
|
|
::= { alarms2 135 }
|
|
|
|
c1LowPresAl_2 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "C1 Low pressure alarm"
|
|
::= { alarms2 136 }
|
|
|
|
c1HighDiscAl_2 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "C1 High discharge alarm"
|
|
::= { alarms2 137 }
|
|
|
|
c1LCompRatAl_2 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "C1 low compresion alarm"
|
|
::= { alarms2 138 }
|
|
|
|
condenser1Al_2 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Condenser 1 general alarm"
|
|
::= { alarms2 139 }
|
|
|
|
c1WatFlowAl_2 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Condenser 1 flow alarm"
|
|
::= { alarms2 140 }
|
|
|
|
eEV1GenAl_2 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "EEV1 general alarm"
|
|
::= { alarms2 141 }
|
|
|
|
eEV1CommAl_2 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "EEV1 communication alarm"
|
|
::= { alarms2 142 }
|
|
|
|
eEV1SuctPrAl_2 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "EEV1 suction temp. probe"
|
|
::= { alarms2 143 }
|
|
|
|
eEV1EvapPrAl_2 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "EEV1 evap. temp. probe"
|
|
::= { alarms2 144 }
|
|
|
|
eEV1CondPrAl_2 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "EEV1 condens. temp. probe"
|
|
::= { alarms2 145 }
|
|
|
|
eEV1DiscPrAl_2 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "EEV1 disch. temp. probe"
|
|
::= { alarms2 146 }
|
|
|
|
c2ThermAl_2 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "C2 Thermal alarm"
|
|
::= { alarms2 147 }
|
|
|
|
c2HighPresAl_2 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "C2 High pressure alarm"
|
|
::= { alarms2 148 }
|
|
|
|
c2LowPresAl_2 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "C2 Low pressure alarm"
|
|
::= { alarms2 149 }
|
|
|
|
c2HighDiscAl_2 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "C2 High discharge alarm"
|
|
::= { alarms2 150 }
|
|
|
|
c2LCompRatAl_2 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "C2 low compresion alarm"
|
|
::= { alarms2 151 }
|
|
|
|
condenser2Al_2 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Condenser 2 general alarm"
|
|
::= { alarms2 152 }
|
|
|
|
c2WatFlowAl_2 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Condenser 2 flow alarm"
|
|
::= { alarms2 153 }
|
|
|
|
eEV2GenAl_2 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "EEV2 general alarm"
|
|
::= { alarms2 154 }
|
|
|
|
eEV2CommAl_2 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "EEV2 communication alarm"
|
|
::= { alarms2 155 }
|
|
|
|
eEV2SuctPrAl_2 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "EEV2 suction temp. probe"
|
|
::= { alarms2 156 }
|
|
|
|
eEV2EvapPrAl_2 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "EEV2 evap. temp. probe"
|
|
::= { alarms2 157 }
|
|
|
|
eEV2CondPrAl_2 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "EEV2 condens. temp. probe"
|
|
::= { alarms2 158 }
|
|
|
|
eEV2DiscPrAl_2 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "EEV2 disch. temp. probe"
|
|
::= { alarms2 159 }
|
|
|
|
intHumGenAl_2 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Internal humidifier alarm"
|
|
::= { alarms2 160 }
|
|
|
|
cPYCommAl_2 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Communication alarm"
|
|
::= { alarms2 161 }
|
|
|
|
cPYMemoryAl_2 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Memory error alarm"
|
|
::= { alarms2 162 }
|
|
|
|
cPYParamAl_2 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Parameters error alarm"
|
|
::= { alarms2 163 }
|
|
|
|
cPYHighCurAl_2 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Electrodes high current"
|
|
::= { alarms2 164 }
|
|
|
|
cPYLoSteamAl_2 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Low steam product. alarm"
|
|
::= { alarms2 165 }
|
|
|
|
cPYDrainAl_2 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Drain loss alarm"
|
|
::= { alarms2 166 }
|
|
|
|
cPYMaintAl_2 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Maintenance hours alarm"
|
|
::= { alarms2 167 }
|
|
|
|
cPYNoWaterAl_2 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Water loss alarm"
|
|
::= { alarms2 168 }
|
|
|
|
cPYCylMainAl_2 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Cylinder mainten. alarm"
|
|
::= { alarms2 169 }
|
|
|
|
cPYDirtCylAl_2 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Exaust cylinder alarm"
|
|
::= { alarms2 170 }
|
|
|
|
cPYFoamAl_2 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Foam presence alarm"
|
|
::= { alarms2 171 }
|
|
|
|
cPYLifeTimAl_2 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Life time expired alarm"
|
|
::= { alarms2 172 }
|
|
|
|
cPYHiWLevAl_2 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "High water level alarm"
|
|
::= { alarms2 173 }
|
|
|
|
cPYHWatConAl_2 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "High conductivity alarm"
|
|
::= { alarms2 174 }
|
|
|
|
cPYConnAl_2 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Connection error alarm"
|
|
::= { alarms2 175 }
|
|
|
|
watPresAl_2 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Water presence alarm"
|
|
::= { alarms2 176 }
|
|
|
|
drainPumpAl_2 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Drain pump alarm"
|
|
::= { alarms2 177 }
|
|
|
|
elHeatAl_2 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Electric heater alarm"
|
|
::= { alarms2 178 }
|
|
|
|
filterAl_2 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Dirty filter alarm"
|
|
::= { alarms2 179 }
|
|
|
|
dryCoolerAl_2 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Dry cooler alarm"
|
|
::= { alarms2 180 }
|
|
|
|
extHumidAl_2 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "External humidifier alarm"
|
|
::= { alarms2 181 }
|
|
|
|
waterPumpAl_2 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Water pump alarm"
|
|
::= { alarms2 182 }
|
|
|
|
condUnitGAl_2 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Motocondenser alarm"
|
|
::= { alarms2 183 }
|
|
|
|
gasLeakAl_2 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Refrigerant leak alarm"
|
|
::= { alarms2 184 }
|
|
|
|
powerSuppAl_2 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Power fault alarm"
|
|
::= { alarms2 185 }
|
|
|
|
genSoftAl_2 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Not critical generic al."
|
|
::= { alarms2 186 }
|
|
|
|
localNetAl_2 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Local network alarm"
|
|
::= { alarms2 187 }
|
|
|
|
regHiTempAl_2 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "High regulation T.alarm"
|
|
::= { alarms2 188 }
|
|
|
|
regLowTempAl_2 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Low regulation T.alarm"
|
|
::= { alarms2 189 }
|
|
|
|
hiLimTempAl_2 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "High limit temp. alarm"
|
|
::= { alarms2 190 }
|
|
|
|
lowLimTempAl_2 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Low limit temp. alarm"
|
|
::= { alarms2 191 }
|
|
|
|
retHiHumiAl_2 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "High room humidity alarm"
|
|
::= { alarms2 192 }
|
|
|
|
retLowHumiAl_2 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Low room humidity alarm"
|
|
::= { alarms2 193 }
|
|
|
|
supHiHumiAl_2 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "High supp.humidity alarm"
|
|
::= { alarms2 194 }
|
|
|
|
supLowHumiAl_2 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Low supp.humidity alarm"
|
|
::= { alarms2 195 }
|
|
|
|
probeMod1COM_2 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Module 1 communication"
|
|
::= { alarms2 196 }
|
|
|
|
prMod1err1_2 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Module 1 probe 1 alarm"
|
|
::= { alarms2 197 }
|
|
|
|
prMod1err2_2 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Module 1 probe 2 alarm"
|
|
::= { alarms2 198 }
|
|
|
|
prMod1err3_2 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Module 1 probe 3 alarm"
|
|
::= { alarms2 199 }
|
|
|
|
prMod1err4_2 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Module 1 probe 4 alarm"
|
|
::= { alarms2 200 }
|
|
|
|
prMod1err5_2 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Module 1 probe 5 alarm"
|
|
::= { alarms2 201 }
|
|
|
|
prMod1err6_2 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Module 1 probe 6 alarm"
|
|
::= { alarms2 202 }
|
|
|
|
probeMod2COM_2 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Module 2 communication"
|
|
::= { alarms2 203 }
|
|
|
|
prMod2err1_2 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Module 2 probe 1 alarm"
|
|
::= { alarms2 204 }
|
|
|
|
prMod2err2_2 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Module 2 probe 2 alarm"
|
|
::= { alarms2 205 }
|
|
|
|
prMod2err3_2 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Module 2 probe 3 alarm"
|
|
::= { alarms2 206 }
|
|
|
|
prMod2err4_2 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Module 2 probe 4 alarm"
|
|
::= { alarms2 207 }
|
|
|
|
prMod2err5_2 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Module 2 probe 5 alarm"
|
|
::= { alarms2 208 }
|
|
|
|
prMod2err6_2 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Module 2 probe 6 alarm"
|
|
::= { alarms2 209 }
|
|
|
|
probeMod3COM_2 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Module 3 communication"
|
|
::= { alarms2 210 }
|
|
|
|
prMod3err1_2 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Module 3 probe 1 alarm"
|
|
::= { alarms2 211 }
|
|
|
|
prMod3err2_2 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Module 3 probe 2 alarm"
|
|
::= { alarms2 212 }
|
|
|
|
prMod3err3_2 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Module 3 probe 3 alarm"
|
|
::= { alarms2 213 }
|
|
|
|
prMod3err4_2 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Module 3 probe 4 alarm"
|
|
::= { alarms2 214 }
|
|
|
|
prMod3err5_2 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Module 3 probe 5 alarm"
|
|
::= { alarms2 215 }
|
|
|
|
prMod3err6_2 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Module 3 probe 6 alarm"
|
|
::= { alarms2 216 }
|
|
END |