160 lines
5.2 KiB
Plaintext
160 lines
5.2 KiB
Plaintext
--End - JUNIPER-WX-STATS-MIB Module
|
|
|
|
-- ========================================================================
|
|
-- Start - JUNIPER-WX-EVENT-MIB Module
|
|
|
|
JUNIPER-WX-EVENT-MIB DEFINITIONS ::= BEGIN
|
|
|
|
IMPORTS
|
|
OBJECT-IDENTITY,
|
|
OBJECT-TYPE,
|
|
NOTIFICATION-TYPE
|
|
FROM SNMPv2-SMI
|
|
DisplayString
|
|
FROM SNMPv2-TC
|
|
jnxWxGrpEvents
|
|
FROM JUNIPER-WX-GLOBAL-MIB;
|
|
|
|
------------------------------
|
|
-- Events Group --
|
|
------------------------------
|
|
|
|
jnxWxGrpEventV2 OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
Branch for SNMPv2 events. The OIDs for SNMPv2 events should
|
|
have a zero as the next-to-last sub-identifier (as specified
|
|
in RFC1902).
|
|
"
|
|
::= { jnxWxGrpEvents 0 }
|
|
|
|
-- Objects sent only in events
|
|
|
|
jnxWxGrpEventDescr OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
String that provides a textual description of the event.
|
|
"
|
|
::= { jnxWxGrpEvents 1 }
|
|
|
|
-- Event descriptions
|
|
|
|
jnxWxGrpEventPowerSupplyFailure NOTIFICATION-TYPE
|
|
STATUS current
|
|
DESCRIPTION
|
|
"One or more sources of power to the system have failed.
|
|
A redundant power-supply has presumably taken over.
|
|
"
|
|
::= { jnxWxGrpEventV2 1 }
|
|
|
|
jnxWxGrpEventPowerSupplyOk NOTIFICATION-TYPE
|
|
STATUS current
|
|
DESCRIPTION
|
|
"One or more previously failed sources of power is now
|
|
working normally. The transition to normal condition happened
|
|
without the system having to be restarted.
|
|
"
|
|
::= { jnxWxGrpEventV2 2 }
|
|
|
|
jnxWxGrpEventLicenseWillExpire NOTIFICATION-TYPE
|
|
OBJECTS { jnxWxGrpEventDescr }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The license for the system is about to
|
|
expire shortly. When it eventually does
|
|
expire, the system will switch over to
|
|
and stay in pass-through mode."
|
|
::= { jnxWxGrpEventV2 3 }
|
|
|
|
jnxWxGrpEventThruputLimitExceeded NOTIFICATION-TYPE
|
|
OBJECTS { jnxWxGrpEventDescr }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The throughput of traffic through the device
|
|
has exceeded the limit for which it has
|
|
been licensed."
|
|
::= { jnxWxGrpEventV2 4 }
|
|
|
|
jnxWxGrpEventLicenseExpired NOTIFICATION-TYPE
|
|
OBJECTS { jnxWxGrpEventDescr }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The license for the system expired.
|
|
As a result, the system will switch over to
|
|
and stay in pass-through mode."
|
|
::= { jnxWxGrpEventV2 5 }
|
|
|
|
jnxWxGrpEventClientLimitExceeded NOTIFICATION-TYPE
|
|
OBJECTS { jnxWxGrpEventDescr }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Exceeded licensed maximum concurrent client connections.
|
|
Please contact Juniper Networks to obtain a new license
|
|
with higher number of concurrent client connections."
|
|
::= { jnxWxGrpEventV2 6 }
|
|
|
|
jnxWxGrpEventInFailSafeMode NOTIFICATION-TYPE
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This trap is sent when the device boots up in fail-safe mode.
|
|
This can happen for one of the following reasons:
|
|
Fail-safe reboot was explicitly initiated by the user.
|
|
The device rebooted automatically too many times because of
|
|
the failure of internal consistency checks or the failure of
|
|
tests that verify proper operation of the device."
|
|
::= { jnxWxGrpEventV2 7 }
|
|
|
|
jnxWxGrpEventInterfaceSpeedMismatch NOTIFICATION-TYPE
|
|
OBJECTS { jnxWxGrpEventDescr }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A mismatch is detected between the local and remote
|
|
interface settings. This can happen due to a mismatch
|
|
in the local and remote interface speed or mode. "
|
|
::= { jnxWxGrpEventV2 8 }
|
|
|
|
jnxWxGrpEventInterfaceSpeedOk NOTIFICATION-TYPE
|
|
OBJECTS { jnxWxGrpEventDescr }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A mismatch previously detected between the local and remote
|
|
interface settings is now resolved. The local and remote
|
|
interface speed and mode are matched. "
|
|
::= { jnxWxGrpEventV2 9 }
|
|
|
|
jnxWxGrpEventInterfaceDuplexMismatch NOTIFICATION-TYPE
|
|
OBJECTS { jnxWxGrpEventDescr }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A possible mismatch was detected between the duplex settings
|
|
of either the local or remote interface and that of the
|
|
device attached to that interface. The interface (local
|
|
or remote) is identified by the 'ifIndex' object.
|
|
|
|
Note that this notification is quite different from
|
|
jnxWxGrpEventInterfaceSpeedMismatch, which compares the
|
|
local and remote interfaces on the same WX device."
|
|
::= { jnxWxGrpEventV2 10 }
|
|
|
|
jnxWxGrpEventLoginFailure NOTIFICATION-TYPE
|
|
OBJECTS { jnxWxGrpEventDescr }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A user's login attempt via the console/ssh/web server
|
|
failed due to incorrect username or password."
|
|
::= { jnxWxGrpEventV2 11 }
|
|
|
|
jnxWxGrpEventDiskFailure NOTIFICATION-TYPE
|
|
OBJECTS { jnxWxGrpEventDescr }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A hard disk failed on the system. The system was rebooted,
|
|
and will now operate without the downed disk, at a degraded
|
|
performance. Dictionary accumulated until this point was lost."
|
|
::= { jnxWxGrpEventV2 12 }
|
|
END
|