TFO-MIB DEFINITIONS ::= BEGIN
|
|
|
|
IMPORTS
|
|
|
|
MODULE-IDENTITY, OBJECT-TYPE, Integer32, enterprises
|
|
FROM SNMPv2-SMI,
|
|
ipi FROM OCNOS-IPI-MODULE-MIB;
|
|
|
|
tfoMIB MODULE-IDENTITY
|
|
LAST-UPDATED "201511300000Z" -- November 30, 2015
|
|
ORGANIZATION "IP Infusion"
|
|
CONTACT-INFO
|
|
"Email: support@ipinfusion.com"
|
|
|
|
DESCRIPTION
|
|
"The MIB module describes the objects to configure
|
|
Trigger FailOver(TFO)."
|
|
|
|
REVISION "201511300000Z"
|
|
DESCRIPTION
|
|
"1st version of TFO MIB"
|
|
::= { ipi 762 }
|
|
|
|
tfoCreate OBJECT IDENTIFIER ::= { tfoMIB 1 }
|
|
|
|
tfoFeature OBJECT-TYPE
|
|
SYNTAX INTEGER { disable(0), enable(1) }
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Global administrative status of TFO.
|
|
TFO is globally disabled by default"
|
|
DEFVAL { disable }
|
|
::= { tfoCreate 1 }
|
|
|
|
|
|
--
|
|
-- TFO If Table
|
|
--
|
|
|
|
tfoIfTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF TfoIfEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A table for all interface which can be mapped to FOG."
|
|
::= { tfoCreate 2 }
|
|
|
|
tfoIfEntry OBJECT-TYPE
|
|
SYNTAX TfoIfEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Attributes of interface link type."
|
|
INDEX { tfoIfIndex }
|
|
::= { tfoIfTable 1 }
|
|
|
|
TfoIfEntry ::= SEQUENCE {
|
|
tfoIfIndex Integer32,
|
|
tfoIfLinkType Integer32
|
|
}
|
|
|
|
tfoIfIndex OBJECT-TYPE
|
|
SYNTAX Integer32 (1..65535)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Index into tfoIfTable."
|
|
::= { tfoIfEntry 1 }
|
|
|
|
tfoIfLinkType OBJECT-TYPE
|
|
SYNTAX INTEGER { unmapped(0), uplink(1), downlink(2) }
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object can be used to configure port as uplink or downlink
|
|
only uplink port can be mapped as MPG and only downlink port
|
|
can be mapped as CPG."
|
|
::= { tfoIfEntry 2 }
|
|
|
|
|
|
--
|
|
-- Fog Table
|
|
--
|
|
|
|
tfoFogTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF TfoFogEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A table for all FailOver Group(FOG) and its information."
|
|
::= { tfoCreate 3 }
|
|
|
|
tfoFogEntry OBJECT-TYPE
|
|
SYNTAX TfoFogEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Attributes of FOG."
|
|
INDEX { tfoFogIndex }
|
|
::= { tfoFogTable 1 }
|
|
|
|
TfoFogEntry ::= SEQUENCE {
|
|
tfoFogIndex Integer32,
|
|
tfoFogCreate Integer32,
|
|
tfoFOGEnable Integer32,
|
|
tfoFogTfcCount Integer32,
|
|
tfoFogMpgLinkFailure Integer32,
|
|
tfoFogMpgLinkRecover Integer32,
|
|
tfoFogCpgAutoEnabled Integer32,
|
|
tfoFogCpgAutoDisabled Integer32
|
|
}
|
|
|
|
tfoFogIndex OBJECT-TYPE
|
|
SYNTAX Integer32 (1..64)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Index into tfoFogTable."
|
|
::= { tfoFogEntry 1 }
|
|
|
|
tfoFogCreate OBJECT-TYPE
|
|
SYNTAX INTEGER { delete(0), add(1) }
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This Object can be used to Create or Delete a FOG
|
|
by specifing the fog index. Fog Index can vary from 1 to 64"
|
|
::= { tfoFogEntry 2 }
|
|
|
|
tfoFOGEnable OBJECT-TYPE
|
|
SYNTAX INTEGER { disable(0), enable(1) }
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This Object can be used to Disable or Enable a FOG
|
|
by specifing the fog index. Fog Index can vary from 1 to 64"
|
|
::= { tfoFogEntry 3 }
|
|
|
|
tfoFogTfcCount OBJECT-TYPE
|
|
SYNTAX Integer32 (0..63)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The Trigger Failover Count to be configured for a FOG.
|
|
Trigger Failover Count can range from 0 to 63."
|
|
DEFVAL { 0 }
|
|
::= { tfoFogEntry 4 }
|
|
|
|
tfoFogMpgLinkFailure OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object specifies number of times MPG's link has failed."
|
|
DEFVAL { 0 }
|
|
::= { tfoFogEntry 5 }
|
|
|
|
tfoFogMpgLinkRecover OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object specifies number of times MPG's link has recovered."
|
|
DEFVAL { 0 }
|
|
::= { tfoFogEntry 6 }
|
|
|
|
tfoFogCpgAutoEnabled OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object specifies number of times CPG's link has been auto-enabled."
|
|
DEFVAL { 0 }
|
|
::= { tfoFogEntry 7 }
|
|
|
|
tfoFogCpgAutoDisabled OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object specifies number of times CPG's link has been auto-disabled."
|
|
DEFVAL { 0 }
|
|
::= { tfoFogEntry 8 }
|
|
|
|
--
|
|
-- Fog Interface Table
|
|
--
|
|
|
|
tfoFogIfTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF TfoFogIfEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A table for Interface mapped to FOG."
|
|
::= { tfoCreate 4 }
|
|
|
|
tfoFogIfEntry OBJECT-TYPE
|
|
SYNTAX TfoFogIfEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Attributes of an FOG interface table."
|
|
INDEX { tfoFogIndex, tfoFogIfIndex }
|
|
::= { tfoFogIfTable 1 }
|
|
|
|
TfoFogIfEntry ::= SEQUENCE {
|
|
tfoFogIfIndex Integer32,
|
|
tfoFogMpgIfConfigure Integer32,
|
|
tfoFogCpgIfConfigure Integer32
|
|
}
|
|
|
|
tfoFogIfIndex OBJECT-TYPE
|
|
SYNTAX Integer32 (1..2147483647)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Index into TfoFogIfTable. Only Physical and LAG interface can be mapped"
|
|
::= { tfoFogIfEntry 1 }
|
|
|
|
tfoFogMpgIfConfigure OBJECT-TYPE
|
|
SYNTAX INTEGER { delete(0), add(1) }
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Uplink Port which can be mapped to Monitor Port Group"
|
|
::= { tfoFogIfEntry 2 }
|
|
tfoFogCpgIfConfigure OBJECT-TYPE
|
|
SYNTAX INTEGER { delete(0), add(1) }
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Downlink Port which can be mapped to Control Port Group"
|
|
::= { tfoFogIfEntry 3 }
|
|
|
|
END
|