7077 lines
256 KiB
Plaintext
7077 lines
256 KiB
Plaintext
-- ============================================================================
|
|
-- Copyright (C) 2011 by HUAWEI TECHNOLOGIES. All rights reserved.
|
|
-- Description: This mib is used for defining the voip test MIB objects.
|
|
-- Reference:
|
|
-- Version: V3.24
|
|
-- ============================================================================
|
|
HUAWEI-NTEST-MIB DEFINITIONS ::= BEGIN
|
|
IMPORTS
|
|
MODULE-IDENTITY, OBJECT-TYPE, NOTIFICATION-TYPE
|
|
FROM SNMPv2-SMI
|
|
huaweiUtility
|
|
FROM HUAWEI-MIB
|
|
ifIndex
|
|
FROM IF-MIB
|
|
hwFrameIndex
|
|
FROM HUAWEI-DEVICE-MIB
|
|
hwTestGroupNo
|
|
FROM HUAWEI-COMMTEST-MIB
|
|
RowStatus
|
|
FROM SNMPv2-TC
|
|
Integer32
|
|
FROM SNMPv2-SMI
|
|
Unsigned32
|
|
FROM SNMPv2-SMI
|
|
IpAddress
|
|
FROM SNMPv2-SMI
|
|
;
|
|
|
|
hwTest OBJECT IDENTIFIER ::= { huaweiUtility 21 }
|
|
|
|
hwNTest MODULE-IDENTITY
|
|
LAST-UPDATED "201105042000Z"
|
|
ORGANIZATION "Huawei Technologies Co.,Ltd."
|
|
CONTACT-INFO
|
|
"Huawei Industrial Base
|
|
Bantian, Longgang
|
|
Shenzhen 518129
|
|
People's Republic of China
|
|
Website: http://www.huawei.com
|
|
Email: support@huawei.com
|
|
"
|
|
DESCRIPTION "This mib is used for defining the voip test MIB objects."
|
|
|
|
-- Revision history
|
|
REVISION "201105042000Z"
|
|
DESCRIPTION "V3.24, change in this revision:
|
|
- Added the following leaf into hwPstnSignalToneTestOprTable
|
|
hwPstnSignalToneTestDTStop
|
|
|
|
- Added the following trap node into hwPstnSignalToneTestOperatorTrap:
|
|
hwPstnSignalToneTestDTStop
|
|
|
|
- Added the following enum into leaf hwPstnSignalToneTestMode:
|
|
invalidValue(-1)
|
|
|
|
- Modified the description of the following enums of leaf hwPstnSignalToneTestOprType:
|
|
invalidValue(-1)
|
|
|
|
- Modified the value range of the following leaves,including:
|
|
hwPstnSignalToneActualDeferTime
|
|
hwPotsSelfCircuitTestDeferredTime
|
|
|
|
- Modified the max access of the following leaf,including:
|
|
hwFrameLooplineAdjustBusyFlag
|
|
"
|
|
|
|
REVISION "201102152000Z"
|
|
DESCRIPTION "V3.23, change in this revision:
|
|
- Added the following leaves into hwPotsSelfCircuitTestOprTable
|
|
hwPotsSelfCircuitTestOnHookDetectResult
|
|
hwPotsSelfCircuitTestOffHookDetectResult
|
|
hwPotsSelfCircuitTestStopRingResult
|
|
hwPotsSelfCircuitTestVPoleResult
|
|
hwPotsSelfCircuitTestVBATLValue
|
|
hwPotsSelfCircuitTestVBATHValue
|
|
hwPotsSelfCircuitTestVBATRValue
|
|
hwPotsSelfCircuitTestRingFValue
|
|
hwPotsSelfCircuitTestVAGValue
|
|
hwPotsSelfCircuitTestVBGValue
|
|
hwPotsSelfCircuitTestVABPoleValue
|
|
hwPotsSelfCircuitTestABLCurrentValue
|
|
hwPotsSelfCircuitTestSLICTempValue
|
|
|
|
- Modified the following leaves in hwPotsSelfCircuitTestOprTable:
|
|
hwPotsSelfCircuitTestVDDResult
|
|
hwPotsSelfCircuitTestVBATLResult
|
|
hwPotsSelfCircuitTestVBATHResult
|
|
hwPotsSelfCircuitTestVBATRResult
|
|
hwPotsSelfCircuitTestLoopCurrentResult
|
|
hwPotsSelfCircuitTestFeedVResult
|
|
hwPotsSelfCircuitTestRingVResult
|
|
hwPotsSelfCircuitTestRingFResult
|
|
hwPotsSelfCircuitTestVAGResult
|
|
hwPotsSelfCircuitTestVBGResult
|
|
hwPotsSelfCircuitTestFeedVValue
|
|
hwPotsSelfCircuitTestRingVValue
|
|
hwPotsSelfCircuitTestLoopCurrentValue
|
|
|
|
- Added the following leaves into hwPstnSignalToneTestOprTable:
|
|
hwPstnSignalToneTestMode
|
|
hwPstnSignalToneTestRequestID
|
|
|
|
- Added the following enums into leaf hwPstnSignalToneTestOprType:
|
|
ringbacktone(5)
|
|
busytone(6)
|
|
|
|
- Modified the description of the following enums of leaf hwPstnSignalToneTestOprType:
|
|
invalidValue(-1)
|
|
|
|
- Modified the description of the following enums of leaf hwPstnSignalToneTestBusyFlag:
|
|
invalidValue(-1)
|
|
|
|
- Modified the value range of the leaves,including:
|
|
hwPstnSignalToneTestDTDelayTime
|
|
hwPstnSignalTonePlayTime
|
|
|
|
- Added the following leaf into hwFrameLooplineAdjustOprTable:
|
|
hwFrameLooplineAdjustBusyFlag
|
|
|
|
- Modified the note of the table hwPotsLooplineThresholdTable
|
|
|
|
- Modified the following leaves in the hwPotsLooplineThresholdTable:
|
|
hwTouchThePowerVolThreshold
|
|
hwLoopLineMixedVolThreshold
|
|
hwOffHookLoopMaxThreshold
|
|
|
|
- Added the following leaves into hwPotsLooplineThresholdTable:
|
|
hwLoopParamsCab
|
|
hwLoopParamsCagbg
|
|
hwLoopParamsRab
|
|
hwLrcThMaxsc
|
|
hwLrcThMaxLg
|
|
hwHdcvL
|
|
hwFacvL
|
|
hwMinetsiSc
|
|
hwMaxetsiSc
|
|
hwMinetsiPr
|
|
hwMaxetsiPr
|
|
hwMinZenerZv
|
|
hwMaxRcrTr
|
|
hwMinRcrTr
|
|
hwCpeCab
|
|
hwMinhrTr
|
|
hwFvcLim
|
|
hwMinOffhookR
|
|
hwLepPar
|
|
hwLooplineThresholdOprType
|
|
|
|
- Modified the definition of the trap node,including:
|
|
hwPstnSignalToneTestOperatorTrap
|
|
hwPotsSelfCircuitTestTrap
|
|
|
|
- Added the following leaves into hwPstnCallerEmulateOprTable:
|
|
hwPstnCallerEmulateTestRequestID
|
|
|
|
- Added the following leaves into hwPstnCalledEmulateOprTable:
|
|
hwPstnCalledEmulateTestRequestID
|
|
|
|
- Added the following trap node into hwPstnCallerEmulateOperatorTrap:
|
|
hwPstnCallerEmulateTestRequestID
|
|
hwPstnCallerEmulateTestResult
|
|
ifIndex
|
|
|
|
- Added the following trap node into hwPstnCalledEmulateOperatorTrap:
|
|
hwPstnCalledEmulateTestRequestID
|
|
hwPstnCalledEmulateTestResult
|
|
ifIndex
|
|
|
|
- Added the following trap node into hwPstnCallEmulateOperatorTrap:
|
|
hwPstnCallEmulateTestResult
|
|
|
|
- Created tables, include:
|
|
hwLineTestParaTable
|
|
hwMonitorTestOprTable
|
|
"
|
|
|
|
REVISION "201012061240Z"
|
|
DESCRIPTION "V3.22, change in this revision:
|
|
-Modified the definition of the leaves,including:
|
|
hwPstnSignalTonePlayTime
|
|
hwPstnSignalToneActualDeferTime
|
|
"
|
|
|
|
REVISION "201011172040Z"
|
|
DESCRIPTION "V3.21, change in this revision:
|
|
-Modified the description
|
|
"
|
|
|
|
REVISION "201008200000Z"
|
|
DESCRIPTION "V3.20, change in this revision:
|
|
- Modified the description of all tables
|
|
"
|
|
|
|
REVISION "201008200000Z"
|
|
DESCRIPTION "V3.19, change in this revision:
|
|
- Modified the definition of the leaves,including:
|
|
hwPstnCallerEmulateTestStatus
|
|
hwPstnCalledEmulateTestStatus
|
|
"
|
|
|
|
REVISION "201008100000Z"
|
|
DESCRIPTION "V3.18, change in this revision:
|
|
- Modified the definition of the leaves,including:
|
|
hwPstnCallEmulateTestSendDTMFPeriod
|
|
hhwPstnCallEmulateTestSendDTMFList
|
|
"
|
|
|
|
REVISION "201007300000Z"
|
|
DESCRIPTION "V3.17, change in this revision:
|
|
- Created tables, include:
|
|
hwPstnCallEmulateConfigTable
|
|
hwPstnCalledEmulateOprTable
|
|
hwPstnCallEmulateOprTable
|
|
"
|
|
|
|
REVISION "201007230000Z"
|
|
DESCRIPTION "V3.16, change in this revision:
|
|
- Modified the description of all tables
|
|
"
|
|
|
|
REVISION "201003240000Z"
|
|
DESCRIPTION "V3.15, change in this revision:
|
|
- Corrected the SYNTAX
|
|
- Modified the definition of the trap node,including:
|
|
hw112IsdnDiagnoseTrap
|
|
hw112IsdnDiagnoseTrap
|
|
hwPotsSelfCircuitTestTrap
|
|
hwPstnCallEmulateOperatorTrap
|
|
|
|
- Added the definition of the trap node,include:
|
|
hwISDNDiagnoseTestTrap
|
|
hwPstnLoopTestTrap
|
|
|
|
- Added the following leaves into hw112IsdnDiagnoseTestOprTable:
|
|
hw112IsdnDiagnoseTestIfIndex
|
|
hw112IsdnDiagnoseTestRequestID
|
|
|
|
- Added the following leaves into hwFrameLooplineAdjustOprTable:
|
|
hwFrameLooplineAdjustFrameIndex
|
|
hwFrameLooplineAdjustRequestID
|
|
|
|
- Added the following leaves into hwPotsSelfCircuitTestOprTable:
|
|
hwPotsSelfCircuitTestLoopIfIndex
|
|
hwPotsSelfCircuitTestLoopRequestID
|
|
|
|
- Added the following leaves into hwISDNDiagnoseTestTable:
|
|
hwISDNDiagnoseTestRequestID
|
|
|
|
- Added the following leaves into hwPstnCallEmulateOprTable:
|
|
hwPstnCallEmulateTestRequestID
|
|
|
|
- Added the following leaves into hwPstnLoopTestOprTable:
|
|
hwPstnLoopTestRequestID
|
|
"
|
|
|
|
::= { hwTest 2 }
|
|
|
|
hwNTestMib OBJECT IDENTIFIER ::= { hwNTest 1 }
|
|
|
|
hwNTestMIBObjects OBJECT IDENTIFIER ::= { hwNTestMib 1 }
|
|
|
|
hwNTestTraps OBJECT IDENTIFIER ::= { hwNTest 2 }
|
|
|
|
hwNTestTrapVbOids OBJECT IDENTIFIER ::= { hwNTestTraps 1 }
|
|
|
|
hwNTestVbOidsReason OBJECT IDENTIFIER ::= { hwNTestTrapVbOids 2 }
|
|
|
|
hwNTestGeneralTraps OBJECT IDENTIFIER ::= { hwNTestTraps 3 }
|
|
hwNTestGeneralTrapsOIDs OBJECT IDENTIFIER ::= { hwNTestGeneralTraps 0 }
|
|
|
|
|
|
hwPstnCircuitTestOprTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF HwPstnCircuitTestOprEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Operation table for the PSTN subscriber circuit test:
|
|
It realizes the function of the circuit test for analog subscribers in the system. The circuit test helps you to ensure that the service board can provide the functions such as ringing, feeder, and dial tone. The circuit test also helps you to ensure that the parameters such as the feeder voltage and ringing current voltage are normal.
|
|
This function facilitates the maintenance of the subscriber circuits, especially the internal circuits of the service boards.
|
|
The index of this table is ifIndex."
|
|
::= { hwNTestMIBObjects 1 }
|
|
|
|
hwPstnCircuitTestOprEntry OBJECT-TYPE
|
|
SYNTAX HwPstnCircuitTestOprEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Operation table for the PSTN subscriber circuit test:
|
|
It realizes the function of the circuit test for analog subscribers in the system. The circuit test helps you to ensure that the service board can provide the functions such as ringing, feeder, and dial tone. The circuit test also helps you to ensure that the parameters such as the feeder voltage and ringing current voltage are normal.
|
|
This function facilitates the maintenance of the subscriber circuits, especially the internal circuits of the service boards.
|
|
The index of this entry is ifIndex."
|
|
INDEX {
|
|
ifIndex
|
|
}
|
|
::= { hwPstnCircuitTestOprTable 1 }
|
|
|
|
HwPstnCircuitTestOprEntry ::=
|
|
SEQUENCE
|
|
{
|
|
hwPstnCircuitTestOprType INTEGER,
|
|
hwPstnCircuitTestOffHook INTEGER,
|
|
hwPstnCircuitTestOffHookCount Integer32,
|
|
hwPstnCircuitTestDialTone INTEGER,
|
|
hwPstnCircuitTestReceivePulse INTEGER,
|
|
hwPstnCircuitTestReceiveDTMF INTEGER,
|
|
hwPstnCircuitTestRingBackTone INTEGER,
|
|
hwPstnCircuitTestBusyTone INTEGER,
|
|
hwPstnCircuitTestBatteryFeed INTEGER,
|
|
hwPstnCircuitTestPoleDetect INTEGER,
|
|
hwPstnCircuitTestOnHook INTEGER,
|
|
hwPstnCircuitTestRing INTEGER,
|
|
hwPstnCircuitTestStopRing INTEGER,
|
|
hwPstnCircuitTestFeedV INTEGER,
|
|
hwPstnCircuitTestRingV INTEGER,
|
|
hwPstnCircuitTestBusyProcFlag INTEGER,
|
|
hwPstnCircuitTestStatus INTEGER,
|
|
hwPstnCircuitTestOffHookResult INTEGER,
|
|
hwPstnCircuitTestDialToneResult INTEGER,
|
|
hwPstnCircuitTestReceivePulseResult INTEGER,
|
|
hwPstnCircuitTestReceiveDTMFResult INTEGER,
|
|
hwPstnCircuitTestRingBackResult INTEGER,
|
|
hwPstnCircuitTestBusyToneResult INTEGER,
|
|
hwPstnCircuitTestBatteryFeedResult INTEGER,
|
|
hwPstnCircuitTestPoleDetectResult INTEGER,
|
|
hwPstnCircuitTestOnHookResult INTEGER,
|
|
hwPstnCircuitTestRingResult INTEGER,
|
|
hwPstnCircuitTestStopRingResult INTEGER,
|
|
hwPstnCircuitTestFeedVValue Integer32,
|
|
hwPstnCircuitTestFeedVResult INTEGER,
|
|
hwPstnCircuitTestRingVValue Integer32,
|
|
hwPstnCircuitTestRingVResult INTEGER,
|
|
hwPstnCircuitTestLoopCurrentValue Integer32,
|
|
hwPstnCircuitTestLoopCurrentResult INTEGER
|
|
}
|
|
|
|
hwPstnCircuitTestOprType OBJECT-TYPE
|
|
SYNTAX INTEGER{stop(1),start(2)}
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Describes the Circuit test-Operation Type.
|
|
Options:
|
|
1. stop(1) -stop the test
|
|
2. start(2) -start the test
|
|
"
|
|
::= { hwPstnCircuitTestOprEntry 1 }
|
|
|
|
hwPstnCircuitTestOffHook OBJECT-TYPE
|
|
SYNTAX INTEGER{notest(1),test(2)}
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Describes the Circuit test-Off hook.
|
|
Options:
|
|
1. notest(1) -no test is applied
|
|
2. test(2) -a test is applied
|
|
"
|
|
::= { hwPstnCircuitTestOprEntry 2 }
|
|
|
|
hwPstnCircuitTestOffHookCount OBJECT-TYPE
|
|
SYNTAX Integer32(1..255)
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Circuit test-Off hook count"
|
|
::= { hwPstnCircuitTestOprEntry 3 }
|
|
|
|
hwPstnCircuitTestDialTone OBJECT-TYPE
|
|
SYNTAX INTEGER{notest(1),test(2)}
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Describes the Circuit test-Dial tone.
|
|
Options:
|
|
1. notest(1) -no test is applied
|
|
2. test(2) -a test is applied
|
|
"
|
|
::= { hwPstnCircuitTestOprEntry 4 }
|
|
|
|
hwPstnCircuitTestReceivePulse OBJECT-TYPE
|
|
SYNTAX INTEGER{notest(1),test(2)}
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Describes the Circuit test-Receiving pulse.
|
|
Options:
|
|
1. notest(1) -no test is applied
|
|
2. test(2) -a test is applied
|
|
"
|
|
::= { hwPstnCircuitTestOprEntry 5 }
|
|
|
|
hwPstnCircuitTestReceiveDTMF OBJECT-TYPE
|
|
SYNTAX INTEGER{notest(1),test(2)}
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Describes the Circuit test-Receiving DTMF.
|
|
Options:
|
|
1. notest(1) -no test is applied
|
|
2. test(2) -a test is applied
|
|
"
|
|
::= { hwPstnCircuitTestOprEntry 6 }
|
|
|
|
hwPstnCircuitTestRingBackTone OBJECT-TYPE
|
|
SYNTAX INTEGER{notest(1),test(2)}
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Describes the Circuit test-Ring back tone.
|
|
Options:
|
|
1. notest(1) -no test is applied
|
|
2. test(2) -a test is applied
|
|
"
|
|
::= { hwPstnCircuitTestOprEntry 7 }
|
|
|
|
hwPstnCircuitTestBusyTone OBJECT-TYPE
|
|
SYNTAX INTEGER{notest(1),test(2)}
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Describes the Circuit test-Busy tone.
|
|
Options:
|
|
1. notest(1) -no test is applied
|
|
2. test(2) -a test is applied
|
|
"
|
|
::= { hwPstnCircuitTestOprEntry 8 }
|
|
|
|
hwPstnCircuitTestBatteryFeed OBJECT-TYPE
|
|
SYNTAX INTEGER{notest(1),test(2)}
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Describes the Circuit test-Feeder .
|
|
Options:
|
|
1. notest(1) -no test is applied
|
|
2. test(2) -a test is applied
|
|
"
|
|
::= { hwPstnCircuitTestOprEntry 9 }
|
|
|
|
hwPstnCircuitTestPoleDetect OBJECT-TYPE
|
|
SYNTAX INTEGER{notest(1),test(2)}
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Describes the Circuit test-Polarity reversal.
|
|
Options:
|
|
1. notest(1) -no test is applied
|
|
2. test(2) -a test is applied
|
|
"
|
|
::= { hwPstnCircuitTestOprEntry 10 }
|
|
|
|
hwPstnCircuitTestOnHook OBJECT-TYPE
|
|
SYNTAX INTEGER{notest(1),test(2)}
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Describes the Circuit test-On hook.
|
|
Options:
|
|
1. notest(1) -no test is applied
|
|
2. test(2) -a test is applied
|
|
"
|
|
::= { hwPstnCircuitTestOprEntry 11 }
|
|
|
|
hwPstnCircuitTestRing OBJECT-TYPE
|
|
SYNTAX INTEGER{notest(1),test(2)}
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Describes the Circuit test-Ringing.
|
|
Options:
|
|
1. notest(1) -no test is applied
|
|
2. test(2) -a test is applied
|
|
"
|
|
::= { hwPstnCircuitTestOprEntry 12 }
|
|
|
|
hwPstnCircuitTestStopRing OBJECT-TYPE
|
|
SYNTAX INTEGER{notest(1),test(2)}
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Describes the Circuit test-Stop ringing.
|
|
Options:
|
|
1. notest(1) -no test is applied
|
|
2. test(2) -a test is applied
|
|
"
|
|
::= { hwPstnCircuitTestOprEntry 13 }
|
|
|
|
hwPstnCircuitTestFeedV OBJECT-TYPE
|
|
SYNTAX INTEGER{notest(1),test(2)}
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Describes the Circuit test-Feeder voltage.
|
|
Options:
|
|
1. notest(1) -no test is applied
|
|
2. test(2) -a test is applied
|
|
"
|
|
::= { hwPstnCircuitTestOprEntry 14 }
|
|
|
|
hwPstnCircuitTestRingV OBJECT-TYPE
|
|
SYNTAX INTEGER{notest(1),test(2)}
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Describes the Circuit test-Ringing current voltage.
|
|
Options:
|
|
1. notest(1) -no test is applied
|
|
2. test(2) -a test is applied
|
|
"
|
|
::= { hwPstnCircuitTestOprEntry 15 }
|
|
|
|
hwPstnCircuitTestBusyProcFlag OBJECT-TYPE
|
|
SYNTAX INTEGER{busynotest(1),busytest(2),busystrentest(3)}
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Describes the Circuit test-Busy control.
|
|
Options:
|
|
1. busynotest(1) -indicates no test when busy
|
|
2. busytest(2) -indicates remedy test when busy
|
|
3. busystrentest(3) -indicates forced test on busy
|
|
"
|
|
::= { hwPstnCircuitTestOprEntry 16 }
|
|
|
|
hwPstnCircuitTestStatus OBJECT-TYPE
|
|
SYNTAX INTEGER{normal(1),testfail(2),portbusy(3),outoftime(4),testingAbnormal(5),broadbandtesting(6),capturefail(7),notratb(8)}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Describes the Circuit test-Inline Test Status.
|
|
Options:
|
|
1. normal(1) -indicates normal
|
|
2. testfail(2) -indicates abnormal
|
|
3. portbusy(3) -indicates busy port
|
|
4. outoftime(4) -indicates timed-out
|
|
5. testingAbnormal(5) -indicates test abnormal
|
|
6. broadbandtesting(6) -indicates broadband testing
|
|
7. capturefail(7) -indicates line capture failure
|
|
8. notratb(8) -indicates relay transfer board not exist
|
|
"
|
|
::= { hwPstnCircuitTestOprEntry 17 }
|
|
|
|
hwPstnCircuitTestOffHookResult OBJECT-TYPE
|
|
SYNTAX INTEGER{normal(1),abnormal(2),testouttime(3),nosupport(4)}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Describes the Circuit Test Result-Off hook.
|
|
Options:
|
|
1. normal(1) -indicates Normal
|
|
2. abnormal(2) -indicates Abnormal
|
|
3. testouttime(3) -indicates time out
|
|
4. nosupport(4) -not support the test
|
|
"
|
|
::= { hwPstnCircuitTestOprEntry 18 }
|
|
|
|
hwPstnCircuitTestDialToneResult OBJECT-TYPE
|
|
SYNTAX INTEGER{normal(1),abnormal(2),testouttime(3),nosupport(4)}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Describes the Circuit Test Result-dial tone.
|
|
Options:
|
|
1. normal(1) -indicates Normal
|
|
2. abnormal(2) -indicates Abnormal
|
|
3. testouttime(3) -indicates time out
|
|
4. nosupport(4) -not support the test
|
|
"
|
|
::= { hwPstnCircuitTestOprEntry 19 }
|
|
|
|
hwPstnCircuitTestReceivePulseResult OBJECT-TYPE
|
|
SYNTAX INTEGER{normal(1),abnormal(2),testouttime(3),nosupport(4)}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Describes the Circuit Test Result-Receiving pulse.
|
|
Options:
|
|
1. normal(1) -indicates Normal
|
|
2. abnormal(2) -indicates Abnormal
|
|
3. testouttime(3) -indicates time out
|
|
4. nosupport(4) -not support the test
|
|
"
|
|
::= { hwPstnCircuitTestOprEntry 20 }
|
|
|
|
hwPstnCircuitTestReceiveDTMFResult OBJECT-TYPE
|
|
SYNTAX INTEGER{normal(1),abnormal(2),testouttime(3),nosupport(4)}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Describes the Circuit Test Result-Receiving DTMF.
|
|
Options:
|
|
1. normal(1) -indicates Normal
|
|
2. abnormal(2) -indicates Abnormal
|
|
3. testouttime(3) -indicates time out
|
|
4. nosupport(4) -not support the test
|
|
"
|
|
::= { hwPstnCircuitTestOprEntry 21 }
|
|
|
|
hwPstnCircuitTestRingBackResult OBJECT-TYPE
|
|
SYNTAX INTEGER{normal(1),abnormal(2),testouttime(3),nosupport(4)}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Describes the Circuit Test Result-Ring back tone.
|
|
Options:
|
|
1. normal(1) -indicates Normal
|
|
2. abnormal(2) -indicates Abnormal
|
|
3. testouttime(3) -indicates time out
|
|
4. nosupport(4) -not support the test
|
|
"
|
|
::= { hwPstnCircuitTestOprEntry 22 }
|
|
|
|
hwPstnCircuitTestBusyToneResult OBJECT-TYPE
|
|
SYNTAX INTEGER{normal(1),abnormal(2),testouttime(3),nosupport(4)}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Describes the Circuit Test Result-Busy tone.
|
|
Options:
|
|
1. normal(1) -indicates Normal
|
|
2. abnormal(2) -indicates Abnormal
|
|
3. testouttime(3) -indicates time out
|
|
4. nosupport(4) -not support the test
|
|
"
|
|
::= { hwPstnCircuitTestOprEntry 23 }
|
|
|
|
hwPstnCircuitTestBatteryFeedResult OBJECT-TYPE
|
|
SYNTAX INTEGER{normal(1),abnormal(2),testouttime(3),nosupport(4)}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Describes the Circuit Test Result-Feeder.
|
|
Options:
|
|
1. normal(1) -indicates Normal
|
|
2. abnormal(2) -indicates Abnormal
|
|
3. testouttime(3) -indicates time out
|
|
4. nosupport(4) -not support the test
|
|
"
|
|
::= { hwPstnCircuitTestOprEntry 24 }
|
|
|
|
hwPstnCircuitTestPoleDetectResult OBJECT-TYPE
|
|
SYNTAX INTEGER{normal(1),abnormal(2),testouttime(3),nosupport(4)}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Describes the Circuit Test Result-Polarity reversal.
|
|
Options:
|
|
1. normal(1) -indicates Normal
|
|
2. abnormal(2) -indicates Abnormal
|
|
3. testouttime(3) -indicates time out
|
|
4. nosupport(4) -not support the test
|
|
"
|
|
::= { hwPstnCircuitTestOprEntry 25 }
|
|
|
|
hwPstnCircuitTestOnHookResult OBJECT-TYPE
|
|
SYNTAX INTEGER{normal(1),abnormal(2),testouttime(3),nosupport(4)}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Describes the Circuit Test Result-On hook.
|
|
Options:
|
|
1. normal(1) -indicates Normal
|
|
2. abnormal(2) -indicates Abnormal
|
|
3. testouttime(3) -indicates time out
|
|
4. nosupport(4) -not support the test
|
|
"
|
|
::= { hwPstnCircuitTestOprEntry 26 }
|
|
|
|
hwPstnCircuitTestRingResult OBJECT-TYPE
|
|
SYNTAX INTEGER{normal(1),abnormal(2),testouttime(3),nosupport(4)}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Describes the Circuit Test Result-Ringing.
|
|
Options:
|
|
1. normal(1) -indicates Normal
|
|
2. abnormal(2) -indicates Abnormal
|
|
3. testouttime(3) -indicates time out
|
|
4. nosupport(4) -not support the test
|
|
"
|
|
::= { hwPstnCircuitTestOprEntry 27 }
|
|
|
|
hwPstnCircuitTestStopRingResult OBJECT-TYPE
|
|
SYNTAX INTEGER{normal(1),abnormal(2),testouttime(3),nosupport(4)}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Describes the Circuit Test Result-Stop ringing.
|
|
Options:
|
|
1. normal(1) -indicates Normal
|
|
2. abnormal(2) -indicates Abnormal
|
|
3. testouttime(3) -indicates time out
|
|
4. nosupport(4) -not support the test
|
|
"
|
|
::= { hwPstnCircuitTestOprEntry 28 }
|
|
|
|
hwPstnCircuitTestFeedVValue OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Describes the Circuit Test Result-Feeder voltage."
|
|
::= { hwPstnCircuitTestOprEntry 29 }
|
|
|
|
hwPstnCircuitTestFeedVResult OBJECT-TYPE
|
|
SYNTAX INTEGER{normal(1),abnormal(2)}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Describes the Circuit Test Result-Feeder voltage Result.
|
|
Options:
|
|
1. normal(1) -indicates Normal
|
|
2. abnormal(2) -indicates Abnormal
|
|
"
|
|
::= { hwPstnCircuitTestOprEntry 30 }
|
|
|
|
hwPstnCircuitTestRingVValue OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Describes the Circuit Test Result-Ringing current voltage.
|
|
Unit: millivolt, ab. mV
|
|
"
|
|
::= { hwPstnCircuitTestOprEntry 31 }
|
|
|
|
hwPstnCircuitTestRingVResult OBJECT-TYPE
|
|
SYNTAX INTEGER{normal(1),abnormal(2)}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Describes the Circuit Test Result-Ringing current voltage Result.
|
|
Options:
|
|
1. normal(1) -indicates Normal
|
|
2. abnormal(2) -indicates Abnormal
|
|
"
|
|
::= { hwPstnCircuitTestOprEntry 32 }
|
|
|
|
hwPstnCircuitTestLoopCurrentValue OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Describes the Circuit Test Result-Loop current.
|
|
Unit: microampere, ab. uA
|
|
"
|
|
::= { hwPstnCircuitTestOprEntry 33 }
|
|
|
|
hwPstnCircuitTestLoopCurrentResult OBJECT-TYPE
|
|
SYNTAX INTEGER{normal(1),abnormal(2)}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Describes the Circuit Test Result-Loop current Result.
|
|
Options:
|
|
1. normal(1) -indicates Normal
|
|
2. abnormal(2) -indicates Abnormal
|
|
"
|
|
::= { hwPstnCircuitTestOprEntry 34 }
|
|
|
|
hwIsdnUserInTestOprTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF HwIsdnUserInTestOprEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Describes the Operation table for the ISDN subscriber circuit test:
|
|
It realizes the function of the circuit test for ISDN subscribers in the system. In the circuit test, the status (activated, deactivated) of the LT U port, LT power supply voltage, LT power supply overflow auto protection, manual switch-off line feeding voltage, and manual switch-on line feeding voltage are measured.
|
|
The test result shows whether the ISDN subscriber circuit works in the normal state.
|
|
The index of this table is ifIndex."
|
|
::= { hwNTestMIBObjects 2 }
|
|
|
|
hwIsdnUserInTestOprEntry OBJECT-TYPE
|
|
SYNTAX HwIsdnUserInTestOprEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Describes the Operation table for the ISDN subscriber circuit test:
|
|
It realizes the function of the circuit test for ISDN subscribers in the system. In the circuit test, the status (activated, deactivated) of the LT U port, LT power supply voltage, LT power supply overflow auto protection, manual switch-off line feeding voltage, and manual switch-on line feeding voltage are measured.
|
|
The test result shows whether the ISDN subscriber circuit works in the normal state.
|
|
The index of this entry is ifIndex."
|
|
INDEX {
|
|
ifIndex
|
|
}
|
|
::= { hwIsdnUserInTestOprTable 1 }
|
|
|
|
HwIsdnUserInTestOprEntry ::=
|
|
SEQUENCE
|
|
{
|
|
hwIsdnUserInTestOprType INTEGER,
|
|
hwIsdnUserInTestActive INTEGER,
|
|
hwIsdnUserInTestDeactive INTEGER,
|
|
hwIsdnUserInTestLtSupplyPowerVol INTEGER,
|
|
hwIsdnUserInTestLtCurrentProctect INTEGER,
|
|
hwIsdnUserInTestCutLineVol INTEGER,
|
|
hwIsdnUserInTestSwitchOnVol INTEGER,
|
|
hwIsdnUserInTestBusyProcFlag INTEGER,
|
|
hwIsdnUserInTestStatus INTEGER,
|
|
hwIsdnUserInTestActiveResult INTEGER,
|
|
hwIsdnUserInTestDeactiveResult INTEGER,
|
|
hwIsdnUserInTestLtSupplyPowerCap Integer32,
|
|
hwIsdnUserInTestLtSupplyPowerCapResult INTEGER,
|
|
hwIsdnUserInTestLtCurrentProctectResult INTEGER,
|
|
hwIsdnUserInTestCutLineVolVal Integer32,
|
|
hwIsdnUserInTestCutLineVolResult INTEGER,
|
|
hwIsdnUserInTestSwitchOnVolVal Integer32,
|
|
hwIsdnUserInTestSwitchOnVolResult INTEGER
|
|
}
|
|
|
|
hwIsdnUserInTestOprType OBJECT-TYPE
|
|
SYNTAX INTEGER{stop(1),start(2)}
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Describes the Operation type.
|
|
Options:
|
|
1. stop(1) -stop the test
|
|
2. start(2) -start the test
|
|
"
|
|
::= { hwIsdnUserInTestOprEntry 1 }
|
|
|
|
hwIsdnUserInTestActive OBJECT-TYPE
|
|
SYNTAX INTEGER{notest(1),test(2)}
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Describes the ISDN subscriber circuit test-Active.
|
|
Options:
|
|
1. notest(1) -no test is applied
|
|
2. test(2) -a test is applied
|
|
"
|
|
::= { hwIsdnUserInTestOprEntry 2 }
|
|
|
|
hwIsdnUserInTestDeactive OBJECT-TYPE
|
|
SYNTAX INTEGER{notest(1),test(2)}
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Describes the ISDN circuit test-Deactive.
|
|
Options:
|
|
1. notest(1) -no test is applied
|
|
2. test(2) -a test is applied
|
|
"
|
|
::= { hwIsdnUserInTestOprEntry 3 }
|
|
|
|
hwIsdnUserInTestLtSupplyPowerVol OBJECT-TYPE
|
|
SYNTAX INTEGER{notest(1),test(2)}
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Describes the ISDN circuit test-LT supply power.
|
|
Options:
|
|
1. notest(1) -no test is applied
|
|
2. test(2) -a test is applied
|
|
"
|
|
::= { hwIsdnUserInTestOprEntry 4 }
|
|
|
|
hwIsdnUserInTestLtCurrentProctect OBJECT-TYPE
|
|
SYNTAX INTEGER{notest(1),test(2)}
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Describes the ISDN circuit test-LT power supply overflow auto protection .
|
|
Options:
|
|
1. notest(1) -no test is applied
|
|
2. test(2) -a test is applied
|
|
"
|
|
::= { hwIsdnUserInTestOprEntry 5 }
|
|
|
|
hwIsdnUserInTestCutLineVol OBJECT-TYPE
|
|
SYNTAX INTEGER{notest(1),test(2)}
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Describes the ISDN circuit test-Manual switch-off line feeding voltage.
|
|
Options:
|
|
1. notest(1) -no test is applied
|
|
2. test(2) -a test is applied
|
|
"
|
|
::= { hwIsdnUserInTestOprEntry 6 }
|
|
|
|
hwIsdnUserInTestSwitchOnVol OBJECT-TYPE
|
|
SYNTAX INTEGER{notest(1),test(2)}
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Describes the ISDN circuit test-Manual switch-on line feeding voltage .
|
|
Options:
|
|
1. notest(1) -no test is applied
|
|
2. test(2) -a test is applied
|
|
"
|
|
::= { hwIsdnUserInTestOprEntry 7 }
|
|
|
|
hwIsdnUserInTestBusyProcFlag OBJECT-TYPE
|
|
SYNTAX INTEGER{busynotest(1),busytest(2),busystrentest(3)}
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Describes the Busy control flag .
|
|
Options:
|
|
1. busynotest(1) -no test when busy
|
|
2. busytest(2) -remedy test when busy
|
|
3. busystrentest(3) -forced test on busy
|
|
"
|
|
::= { hwIsdnUserInTestOprEntry 8 }
|
|
|
|
hwIsdnUserInTestStatus OBJECT-TYPE
|
|
SYNTAX INTEGER{normal(1),abnormal(2),portbusy(3),outoftime(4),testingAbnormal(5)}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Describes the Test status .
|
|
Options:
|
|
1. normal(1) -indicates normal
|
|
2. abnormal(2) -indicates abnormal
|
|
3. portbusy(3) -indicates busy port
|
|
4. outoftime(4) -indicates timed-out
|
|
5. testingAbnormal(5) -indicates test abnormal
|
|
"
|
|
::= { hwIsdnUserInTestOprEntry 9 }
|
|
|
|
hwIsdnUserInTestActiveResult OBJECT-TYPE
|
|
SYNTAX INTEGER{normal(1),abnormal(2),outOfTime(3),notest(4)}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Describes the Activation result .
|
|
Options:
|
|
1. normal(1) -indicates normal
|
|
2. abnormal(2) -indicates abnormal
|
|
3. outOfTime(3) -indicates timed-out
|
|
4. notest(4) -indicates no test
|
|
"
|
|
::= { hwIsdnUserInTestOprEntry 10 }
|
|
|
|
hwIsdnUserInTestDeactiveResult OBJECT-TYPE
|
|
SYNTAX INTEGER{normal(1),abnormal(2),outoftime(3),notest(4)}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Describes the Deactivation result.
|
|
Options:
|
|
1. normal(1) -indicates normal
|
|
2. abnormal(2) -indicates abnormal
|
|
3. outoftime(3) -indicates timed-out
|
|
4. notest(4) -indicates no test
|
|
"
|
|
::= { hwIsdnUserInTestOprEntry 11 }
|
|
|
|
hwIsdnUserInTestLtSupplyPowerCap OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"LT power supply voltage
|
|
Unit: millivolt"
|
|
::= { hwIsdnUserInTestOprEntry 12 }
|
|
|
|
hwIsdnUserInTestLtSupplyPowerCapResult OBJECT-TYPE
|
|
SYNTAX INTEGER{normal(1),abnormal(2),outOfTime(3),notest(4),dslBoardNoSupport(5)}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Describes the Test result-LT power supply voltage.
|
|
Options:
|
|
1. normal(1) -indicates normal
|
|
2. abnormal(2) -indicates abnormal
|
|
3. outOfTime(3) -indicates timed-out
|
|
4. notest(4) -indicates no test
|
|
5. dslBoardNoSupport(5) -indicates not supported by the DSL02 board
|
|
"
|
|
::= { hwIsdnUserInTestOprEntry 13 }
|
|
|
|
hwIsdnUserInTestLtCurrentProctectResult OBJECT-TYPE
|
|
SYNTAX INTEGER{outOfTime(1),noProtect(2),protectNoRestore(3),protectAndRestore(4),dslBoardNoSupport(5)}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Describes the LT over current auto-protection capability .
|
|
Options:
|
|
1. outOfTime(1) -indicates timed-out
|
|
2. noProtect(2) -indicates not protected
|
|
3. protectNoRestore(3) -indicates protected but not restored automatically
|
|
4. protectAndRestore(4) -indicates protected and restored automatically
|
|
5. dslBoardNoSupport(5) -indicates not supported by the DSL02 board
|
|
"
|
|
::= { hwIsdnUserInTestOprEntry 14 }
|
|
|
|
hwIsdnUserInTestCutLineVolVal OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Describes the Manual switch-off line feeding voltage.
|
|
Unit: millivolt, ab. mV
|
|
"
|
|
::= { hwIsdnUserInTestOprEntry 15 }
|
|
|
|
hwIsdnUserInTestCutLineVolResult OBJECT-TYPE
|
|
SYNTAX INTEGER{normal(1),abnormal(2),outOfTime(3),notest(4),dslBoardNoSupport(5)}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Describes the Test result-Manual switch-off line feeding voltage.
|
|
Options:
|
|
1. normal(1) -indicates normal
|
|
2. abnormal(2) -indicates abnormal
|
|
3. outOfTime(3) -indicates timed-out
|
|
4. notest(4) -indicates no test
|
|
5. dslBoardNoSupport(5) -indicates not supported by the DSL02 board
|
|
"
|
|
::= { hwIsdnUserInTestOprEntry 16 }
|
|
|
|
hwIsdnUserInTestSwitchOnVolVal OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Describes the Switch on voltage.
|
|
Unit: millivolt, ab. mV
|
|
"
|
|
::= { hwIsdnUserInTestOprEntry 17 }
|
|
|
|
hwIsdnUserInTestSwitchOnVolResult OBJECT-TYPE
|
|
SYNTAX INTEGER{normal(1),abnormal(2),outOfTime(3),notest(4),dslBoardNoSupport(5)}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Describes the Test result-switch on voltage.
|
|
Options:
|
|
1. normal(1) -indicates normal
|
|
2. abnormal(2) -indicates abnormal
|
|
3. outOfTime(3) -indicates timed-out
|
|
4. notest(4) -indicates no test
|
|
5. dslBoardNoSupport(5) -indicates not supported by the DSL02 board
|
|
"
|
|
::= { hwIsdnUserInTestOprEntry 18 }
|
|
|
|
hwIsdnUserOutTestOprTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF HwIsdnUserOutTestOprEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Operation table for the ISDN subscriber loop-line test:
|
|
It realizes the function of the loop-line test for ISDN subscribers in the system. In the loop-line test, the Activate NT1, Deactivate NT1, and Transmission Bit Error Rate are tested.
|
|
The index of this table is ifIndex."
|
|
::= { hwNTestMIBObjects 3 }
|
|
|
|
hwIsdnUserOutTestOprEntry OBJECT-TYPE
|
|
SYNTAX HwIsdnUserOutTestOprEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Operation table for the ISDN subscriber loop-line test:
|
|
It realizes the function of the loop-line test for ISDN subscribers in the system. In the loop-line test, the Activate NT1, Deactivate NT1, and Transmission Bit Error Rate are tested.
|
|
The index of this entry is ifIndex."
|
|
INDEX {
|
|
ifIndex
|
|
}
|
|
::= { hwIsdnUserOutTestOprTable 1 }
|
|
|
|
HwIsdnUserOutTestOprEntry ::=
|
|
SEQUENCE
|
|
{
|
|
hwIsdnUserOutTestOprType INTEGER,
|
|
hwIsdnUserOutTestActiveNT1 INTEGER,
|
|
hwIsdnUserOutTestDeactiveNT1 INTEGER,
|
|
hwIsdnUserOutTestTransBitError INTEGER,
|
|
hwIsdnUserOutTestErrCodeTestTime Integer32,
|
|
hwIsdnUserOutTestBusyProcessFlag INTEGER,
|
|
hwIsdnUserOutTestStatus INTEGER,
|
|
hwIsdnUserOutTestActNT1Result INTEGER,
|
|
hwIsdnUserOutTestDeactNT1Result INTEGER,
|
|
hwIsdnUserOutTestTransBitErrorResult INTEGER,
|
|
hwIsdnUserOutTestTotalSend Integer32,
|
|
hwIsdnUserOutTestCodeErrorNumber Integer32,
|
|
hwIsdnUserOutTestCodeErrorRate Integer32
|
|
}
|
|
|
|
hwIsdnUserOutTestOprType OBJECT-TYPE
|
|
SYNTAX INTEGER{stop(1),start(2)}
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Describes the Operation type.
|
|
Options:
|
|
1. stop(1) -stop the test
|
|
2. start(2) -start the test
|
|
"
|
|
::= { hwIsdnUserOutTestOprEntry 1 }
|
|
|
|
hwIsdnUserOutTestActiveNT1 OBJECT-TYPE
|
|
SYNTAX INTEGER{notest(1),test(2)}
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Describes the ISDN loop line test-Activate NT1.
|
|
Options:
|
|
1. notest(1) -no test is applied
|
|
2. test(2) -a test is applied
|
|
"
|
|
::= { hwIsdnUserOutTestOprEntry 2 }
|
|
|
|
hwIsdnUserOutTestDeactiveNT1 OBJECT-TYPE
|
|
SYNTAX INTEGER{notest(1),test(2)}
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Describes the ISDN loop line test-Deactivate NT1.
|
|
Options:
|
|
1. notest(1) -no test is applied
|
|
2. test(2) -a test is applied
|
|
"
|
|
::= { hwIsdnUserOutTestOprEntry 3 }
|
|
|
|
hwIsdnUserOutTestTransBitError OBJECT-TYPE
|
|
SYNTAX INTEGER{notest(1),test(2)}
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Describes the ISDN loop line test-Transmission Bit Error Rate.
|
|
Options:
|
|
1. notest(1) -no test is applied
|
|
2. test(2) -a test is applied
|
|
"
|
|
::= { hwIsdnUserOutTestOprEntry 4 }
|
|
|
|
hwIsdnUserOutTestErrCodeTestTime OBJECT-TYPE
|
|
SYNTAX Integer32(1..255)
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Describes the Bit Error Rate Test Duration.
|
|
Unit: s.
|
|
Default: 120 s for the EMS
|
|
"
|
|
DEFVAL { 120 }
|
|
::= { hwIsdnUserOutTestOprEntry 5 }
|
|
|
|
hwIsdnUserOutTestBusyProcessFlag OBJECT-TYPE
|
|
SYNTAX INTEGER{busyNoTest(1),busyTest(2)}
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Describes the Busy control flag.
|
|
Options:
|
|
1. busyNoTest(1) -indicates no test when busy
|
|
2. busyTest(2) -indicates remedy test when busy
|
|
"
|
|
::= { hwIsdnUserOutTestOprEntry 6 }
|
|
|
|
hwIsdnUserOutTestStatus OBJECT-TYPE
|
|
SYNTAX INTEGER{normal(1),abnormal(2),portbusy(3),outoftime(4),testingAbnormal(5) }
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Describes the Test status.
|
|
Options:
|
|
1. normal(1) -indicates normal
|
|
2. abnormal(2) -indicates abnormal
|
|
3. portbusy(3) -indicates busy port
|
|
4. outoftime(4) -indicates timed-out
|
|
5. testingAbnormal(5) -indicates test abnormal
|
|
"
|
|
::= { hwIsdnUserOutTestOprEntry 7 }
|
|
|
|
hwIsdnUserOutTestActNT1Result OBJECT-TYPE
|
|
SYNTAX INTEGER{normal(1),activeFail(2),noNt1OrNt1NotUse(3),activeUifSuccess(4),activeUifAndSifSuccess(5),outOfTime(6),startTestFail(7)}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Describes the Activation NT1 result .
|
|
Options:
|
|
1. normal(1) -indicates Normal
|
|
2. activeFail(2) -indicates failure
|
|
3. noNt1OrNt1NotUse(3) -indicates no NT1 or NT1 is unavailable
|
|
4. activeUifSuccess(4) -indicates U port activated successfully
|
|
5. activeUifAndSifSuccess(5) -indicates U and S ports activated successfully
|
|
6. outOfTime(6) -indicates Timed-out
|
|
7. startTestFail(7) -indicates starting test fails
|
|
"
|
|
::= { hwIsdnUserOutTestOprEntry 8 }
|
|
|
|
hwIsdnUserOutTestDeactNT1Result OBJECT-TYPE
|
|
SYNTAX INTEGER{normal(1),abnormal(2),outoftime(3),notest(4)}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Describes the Test result-Deactivate NT1.
|
|
Options:
|
|
1. normal(1) -indicates normal
|
|
2. abnormal(2) -indicates abnormal
|
|
3. outoftime(3) -indicates timed-out
|
|
4. notest(4) -indicates not tested
|
|
"
|
|
::= { hwIsdnUserOutTestOprEntry 9 }
|
|
|
|
hwIsdnUserOutTestTransBitErrorResult OBJECT-TYPE
|
|
SYNTAX INTEGER{normal(1),nt1BadOrNoTexist(2),nt1ActiveFail(3),nt1LoopFail(4),syncFail(5),outOfTime(6),notest(7)}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Describes the Test result-Transmission bit error rate.
|
|
Options:
|
|
1. normal(1) -indicates normal
|
|
2. nt1BadOrNoTexist(2) -indicates NT1 is bad or no NT1
|
|
3. nt1ActiveFail(3) -indicates activating NT1 fails
|
|
4. nt1LoopFail(4) -indicates loopback on NT1 fails
|
|
5. syncFail(5) -indicates bit error rate is too high and synchronization fails
|
|
6. outOfTime(6) -indicates timed-out
|
|
7. notest(7) -indicates not tested)
|
|
"
|
|
::= { hwIsdnUserOutTestOprEntry 10 }
|
|
|
|
hwIsdnUserOutTestTotalSend OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Describes the Total number of sent bits"
|
|
::= { hwIsdnUserOutTestOprEntry 11 }
|
|
|
|
hwIsdnUserOutTestCodeErrorNumber OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Describes the Number of bit errors"
|
|
::= { hwIsdnUserOutTestOprEntry 12 }
|
|
|
|
hwIsdnUserOutTestCodeErrorRate OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Describes the Bit error rate"
|
|
::= { hwIsdnUserOutTestOprEntry 13 }
|
|
|
|
hwIsdnUserOutLineTestOprTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF HwIsdnUserOutLineTestOprEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Operation table for the ISDN subscriber loop-line test.
|
|
It realizes the function of the loop-line test for ISDN subscribers in the system. In the loop-line test, the voltage, resistance and capacitance of the loop line are tested to check for faults such as broken circuit, short circuit, grounding and cross-connected line.
|
|
The index of this table is ifIndex"
|
|
::= { hwNTestMIBObjects 4 }
|
|
|
|
hwIsdnUserOutLineTestOprEntry OBJECT-TYPE
|
|
SYNTAX HwIsdnUserOutLineTestOprEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Operation table for the ISDN subscriber loop-line test.
|
|
It realizes the function of the loop-line test for ISDN subscribers in the system. In the loop-line test, the voltage, resistance and capacitance of the loop line are tested to check for faults such as broken circuit, short circuit, grounding and cross-connected line.
|
|
The index of this entry is ifIndex"
|
|
INDEX {
|
|
ifIndex
|
|
}
|
|
::= { hwIsdnUserOutLineTestOprTable 1 }
|
|
|
|
HwIsdnUserOutLineTestOprEntry ::=
|
|
SEQUENCE
|
|
{
|
|
hwIsdnUserOutLineTestOprType INTEGER,
|
|
hwIsdnUserOutLineTestVoltage INTEGER,
|
|
hwIsdnUserOutLineTestResistance INTEGER,
|
|
hwIsdnUserOutLineTestCapacitance INTEGER,
|
|
hwIsdnUserOutLineTestBusyProcFlag INTEGER,
|
|
hwIsdnUserOutLineTestStatus INTEGER,
|
|
hwIsdnUserOutLineTestConclusion Integer32,
|
|
hwIsdnUserOutLineTestACAG Integer32,
|
|
hwIsdnUserOutLineTestACBG Integer32,
|
|
hwIsdnUserOutLineTestACAB Integer32,
|
|
hwIsdnUserOutLineTestDCAG Integer32,
|
|
hwIsdnUserOutLineTestDCBG Integer32,
|
|
hwIsdnUserOutLineTestDCAB Integer32,
|
|
hwIsdnUserOutLineTestRAG Integer32,
|
|
hwIsdnUserOutLineTestRBG Integer32,
|
|
hwIsdnUserOutLineTestRAB Integer32,
|
|
hwIsdnUserOutLineTestCapAG Integer32,
|
|
hwIsdnUserOutLineTestCapBG Integer32,
|
|
hwIsdnUserOutLineTestCapAB Integer32,
|
|
hwIsdnUserOutLineTestImpedance INTEGER,
|
|
hwIsdnUserOutLineTestImpedanceAB Integer32,
|
|
hwIsdnUserOutLineTestImpedanceBA Integer32,
|
|
hwIsdnUserOutLineTestImpedanceAG Integer32,
|
|
hwIsdnUserOutLineTestImpedanceBG Integer32,
|
|
hwIsdnUserOutLineTestCurrent INTEGER,
|
|
hwIsdnUserOutLineTestACCurrentAG Integer32,
|
|
hwIsdnUserOutLineTestACCurrentBG Integer32,
|
|
hwIsdnUserOutLineTestACCurrentAB Integer32,
|
|
hwIsdnUserOutLineTestDCCurrentAG Integer32,
|
|
hwIsdnUserOutLineTestDCCurrentBG Integer32,
|
|
hwIsdnUserOutLineTestDCCurrentAB Integer32,
|
|
hwIsdnUserOutLineTestLoopCurrent INTEGER,
|
|
hwIsdnUserOutLineTestLC Integer32,
|
|
hwIsdnUserOutLineTestNoise INTEGER,
|
|
hwIsdnUserOutLineTestN Integer32
|
|
}
|
|
|
|
hwIsdnUserOutLineTestOprType OBJECT-TYPE
|
|
SYNTAX INTEGER{stop(1),start(2)}
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Describes the Operation type.
|
|
Options:
|
|
1. stop(1) -stop the test
|
|
2. start(2) -start the test
|
|
"
|
|
::= { hwIsdnUserOutLineTestOprEntry 1 }
|
|
|
|
hwIsdnUserOutLineTestVoltage OBJECT-TYPE
|
|
SYNTAX INTEGER{notest(1),test(2)}
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"ISDN loop line test-Voltage.
|
|
Options:
|
|
1. notest(1) -no test is applied
|
|
2. test(2) -a test is applied
|
|
"
|
|
::= { hwIsdnUserOutLineTestOprEntry 2 }
|
|
|
|
hwIsdnUserOutLineTestResistance OBJECT-TYPE
|
|
SYNTAX INTEGER{notest(1),test(2)}
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"ISDN loop line test-Resistance.
|
|
Options:
|
|
1. notest(1) -no test is applied
|
|
2. test(2) -a test is applied
|
|
"
|
|
::= { hwIsdnUserOutLineTestOprEntry 3 }
|
|
|
|
hwIsdnUserOutLineTestCapacitance OBJECT-TYPE
|
|
SYNTAX INTEGER{notest(1),test(2)}
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"ISDN loop line test-Capacitance.
|
|
Options:
|
|
1. notest(1) -no test is applied
|
|
2. test(2) -a test is applied
|
|
"
|
|
::= { hwIsdnUserOutLineTestOprEntry 4 }
|
|
|
|
hwIsdnUserOutLineTestBusyProcFlag OBJECT-TYPE
|
|
SYNTAX INTEGER{busyNoTest(1),busyTest (2)}
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Busy control flag .
|
|
Options:
|
|
1. busyNoTest(1) -indicates no test when busy
|
|
2. busyTest(2) -indicates remedy test when busy
|
|
"
|
|
::= { hwIsdnUserOutLineTestOprEntry 5 }
|
|
|
|
hwIsdnUserOutLineTestStatus OBJECT-TYPE
|
|
SYNTAX INTEGER{normal(1),abnormal(2),portbusy(3),outoftime(4),testingAbnormal(5)}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Test status.
|
|
Options:
|
|
1. normal(1) -indicates normal
|
|
2. abnormal(2) -indicates abnormal
|
|
3. portbusy(3) -indicates busy port
|
|
4. outoftime(4) -indicates timed-out
|
|
5. testingAbnormal(5) -indicates test abnormal
|
|
"
|
|
::= { hwIsdnUserOutLineTestOprEntry 6 }
|
|
|
|
hwIsdnUserOutLineTestConclusion OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Conclusion
|
|
Range:1-89
|
|
(Enumerated type.
|
|
1: Normal 2: Contact with the power line 3: A line mixed with others 4: B line mixed with others
|
|
5: Mixed with others (two lines) 6: A line grounding 7: B line grounding 8: AB grounding
|
|
9: Self-mixed (small resistance, self-mixed) 10: A-B poor insulation 11: A-ground leakage
|
|
12: B-ground leakage 13: AB ground leakage 14: A-B leakage 15: NT1 not connected
|
|
16: not on-hook 17: unknown 18: self-Mixed(inMDF) 19: self-Mixed(outMDF) 20: cutLine(inMDF) 21: cutLine(outMDF)
|
|
22: A-B voltage abnormal 23:lines voltage abnormal 24:lines resistance abnormal 25: A-B resistance abnormal
|
|
26: self-mixed (small resistance, self-mixed) or not on-hook 27:lines abnormal
|
|
30: DC voltage(Power feed) 31: AC voltage(Ringing)
|
|
32: DC voltage(Offhook) 33: DC voltage 34: AC voltage
|
|
60: A->ground AC voltage abnormal 61: B->ground AC voltage abnormal 62: AB-ground AC voltage abnormal
|
|
63: AB->ground DC voltage abnormal 64: A->ground DC voltage abnormal 65: B->ground DC voltage abnormal
|
|
66: A-B DC voltage abnormal 67: A->ground insulation resistance abnormal 68: B->ground insulation resistance abnormal
|
|
69: AB->ground insulation resistance abnormal 70: A->ground poor insulation 71: B->ground poor insulation
|
|
72: AB->ground poor insulation 73: A->ground impedance abnormal 74: B->ground impedance abnormal
|
|
75: A->B impedance abnormal 76: B->A impedance abnormal 77: A->ground AC current abnormal
|
|
78: B->ground AC current abnormal 79: A-B AC current abnormal 80: A->ground DC current abnormal
|
|
81: B->ground DC current abnormal 82: A-B DC current abnormal 83: loop current abnormal
|
|
84: loop resistance abnormal 85: AB->ground capacitance abnormal 86: A->ground capacitance abnomal
|
|
87: B->ground capacitacne abnormal 88: A-B capacitance abnomal 89: noise abnomal"
|
|
::= { hwIsdnUserOutLineTestOprEntry 7 }
|
|
|
|
hwIsdnUserOutLineTestACAG OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A->ground AC voltage.
|
|
Unit: millivolt, ab. mV
|
|
"
|
|
::= { hwIsdnUserOutLineTestOprEntry 8 }
|
|
|
|
hwIsdnUserOutLineTestACBG OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"B->ground AC voltage.
|
|
Unit: millivolt, ab. mV
|
|
"
|
|
::= { hwIsdnUserOutLineTestOprEntry 9 }
|
|
|
|
hwIsdnUserOutLineTestACAB OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A->B AC voltage.
|
|
Unit: millivolt, ab. mV
|
|
"
|
|
::= { hwIsdnUserOutLineTestOprEntry 10 }
|
|
|
|
hwIsdnUserOutLineTestDCAG OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A->ground DC voltage.
|
|
Unit: millivolt, ab. mV
|
|
"
|
|
::= { hwIsdnUserOutLineTestOprEntry 11 }
|
|
|
|
hwIsdnUserOutLineTestDCBG OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"B->ground DC voltage.
|
|
Unit: millivolt, ab. mV
|
|
"
|
|
::= { hwIsdnUserOutLineTestOprEntry 12 }
|
|
|
|
hwIsdnUserOutLineTestDCAB OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A->B DC voltage.
|
|
Unit: millivolt, ab. mV
|
|
"
|
|
::= { hwIsdnUserOutLineTestOprEntry 13 }
|
|
|
|
hwIsdnUserOutLineTestRAG OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A->ground insulation resistance.
|
|
Unit: ohm
|
|
"
|
|
::= { hwIsdnUserOutLineTestOprEntry 14 }
|
|
|
|
hwIsdnUserOutLineTestRBG OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"B->ground insulation resistance.
|
|
Unit: ohm
|
|
"
|
|
::= { hwIsdnUserOutLineTestOprEntry 15 }
|
|
|
|
hwIsdnUserOutLineTestRAB OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A->B insulation resistance.
|
|
Unit: ohm
|
|
"
|
|
::= { hwIsdnUserOutLineTestOprEntry 16 }
|
|
|
|
hwIsdnUserOutLineTestCapAG OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A->ground capacitance.
|
|
Unit: nF
|
|
"
|
|
::= { hwIsdnUserOutLineTestOprEntry 17 }
|
|
|
|
hwIsdnUserOutLineTestCapBG OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"B->ground capacitance.
|
|
Unit: nF
|
|
"
|
|
::= { hwIsdnUserOutLineTestOprEntry 18 }
|
|
|
|
hwIsdnUserOutLineTestCapAB OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A->B capacitance.
|
|
Unit: nF
|
|
"
|
|
::= { hwIsdnUserOutLineTestOprEntry 19 }
|
|
|
|
hwIsdnUserOutLineTestImpedance OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
notest(1),
|
|
test(2)
|
|
}
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Loop-Line Test-Impedance.
|
|
Options:
|
|
1. notest(1) -no test is applied
|
|
2. test(2) -a test is applied
|
|
"
|
|
::= { hwIsdnUserOutLineTestOprEntry 20 }
|
|
|
|
hwIsdnUserOutLineTestImpedanceAB OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A->B impedance.
|
|
Unit: ohm
|
|
"
|
|
::= { hwIsdnUserOutLineTestOprEntry 21 }
|
|
|
|
hwIsdnUserOutLineTestImpedanceBA OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"B->A impedance.
|
|
Unit: ohm
|
|
"
|
|
::= { hwIsdnUserOutLineTestOprEntry 22 }
|
|
|
|
hwIsdnUserOutLineTestImpedanceAG OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A->ground impedance.
|
|
Unit: ohm
|
|
"
|
|
::= { hwIsdnUserOutLineTestOprEntry 23 }
|
|
|
|
hwIsdnUserOutLineTestImpedanceBG OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"B->ground impedance.
|
|
Unit: ohm
|
|
"
|
|
::= { hwIsdnUserOutLineTestOprEntry 24 }
|
|
|
|
|
|
hwIsdnUserOutLineTestCurrent OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
notest(1),
|
|
test(2)
|
|
}
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Loop line test-Current.
|
|
Options:
|
|
1. notest(1) -no test is applied
|
|
2. test(2) -a test is applied
|
|
"
|
|
::= { hwIsdnUserOutLineTestOprEntry 25 }
|
|
|
|
hwIsdnUserOutLineTestACCurrentAG OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A->ground AC current
|
|
Unit: mA
|
|
"
|
|
::= { hwIsdnUserOutLineTestOprEntry 26 }
|
|
|
|
hwIsdnUserOutLineTestACCurrentBG OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"B->ground AC current.
|
|
Unit: mA
|
|
"
|
|
::= { hwIsdnUserOutLineTestOprEntry 27 }
|
|
|
|
hwIsdnUserOutLineTestACCurrentAB OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"AB AC current.
|
|
Unit: mA
|
|
"
|
|
::= { hwIsdnUserOutLineTestOprEntry 28 }
|
|
|
|
hwIsdnUserOutLineTestDCCurrentAG OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A->ground DC current.
|
|
Unit: mA
|
|
"
|
|
::= { hwIsdnUserOutLineTestOprEntry 29 }
|
|
|
|
hwIsdnUserOutLineTestDCCurrentBG OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"B->ground DC current.
|
|
Unit: mA
|
|
"
|
|
::= { hwIsdnUserOutLineTestOprEntry 30 }
|
|
|
|
hwIsdnUserOutLineTestDCCurrentAB OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"AB DC current.
|
|
Unit: mA
|
|
"
|
|
::= { hwIsdnUserOutLineTestOprEntry 31 }
|
|
|
|
hwIsdnUserOutLineTestLoopCurrent OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
notest(1),
|
|
test(2)
|
|
}
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Loop-Line Test-Loop Current.
|
|
Options:
|
|
1. notest(1) -no test is applied
|
|
2. test(2) -a test is applied
|
|
"
|
|
::= { hwIsdnUserOutLineTestOprEntry 32 }
|
|
|
|
hwIsdnUserOutLineTestLC OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Loop Current.
|
|
Unit: mA
|
|
"
|
|
::= { hwIsdnUserOutLineTestOprEntry 33 }
|
|
|
|
hwIsdnUserOutLineTestNoise OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
notest(1),
|
|
test(2)
|
|
}
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Loop-Line Test-Noise .
|
|
Options:
|
|
1. notest(1) -no test is applied
|
|
2. test(2) -a test is applied
|
|
"
|
|
::= { hwIsdnUserOutLineTestOprEntry 34 }
|
|
|
|
hwIsdnUserOutLineTestN OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Noise.
|
|
Unit: dBm
|
|
"
|
|
::= { hwIsdnUserOutLineTestOprEntry 35 }
|
|
|
|
hwIsdnPortStateSwitchTestOprTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF HwIsdnPortStateSwitchTestOprEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Operation table for the test on ISDN port status switching:
|
|
It realizes the function of the test on ISDN port status switching in the system. In the test, the status of a port is switched between NT1 and LT to check whether the NT1 and LT functions of the port work.
|
|
The index of this table is ifIndex"
|
|
::= { hwNTestMIBObjects 5 }
|
|
|
|
hwIsdnPortStateSwitchTestOprEntry OBJECT-TYPE
|
|
SYNTAX HwIsdnPortStateSwitchTestOprEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Operation table for the test on ISDN port status switching:
|
|
It realizes the function of the test on ISDN port status switching in the system. In the test, the status of a port is switched between NT1 and LT to check whether the NT1 and LT functions of the port work.
|
|
The index of this entry is ifIndex"
|
|
INDEX {
|
|
ifIndex
|
|
}
|
|
::= { hwIsdnPortStateSwitchTestOprTable 1 }
|
|
|
|
HwIsdnPortStateSwitchTestOprEntry ::=
|
|
SEQUENCE
|
|
{
|
|
hwIsdnPortStateSwitchTestOprType INTEGER,
|
|
hwIsdnPortStateSwitchTestStatus INTEGER
|
|
}
|
|
|
|
hwIsdnPortStateSwitchTestOprType OBJECT-TYPE
|
|
SYNTAX INTEGER{switchNT1(1),switchLT(2),switchnormal(3)}
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Operation type .
|
|
Options:
|
|
1. switchNT1(1) -indicates Switch to NT1
|
|
2. switchLT(2) -indicates Switch to LT
|
|
3. switchnormal(3) -indicates Switch to the normal state
|
|
"
|
|
::= { hwIsdnPortStateSwitchTestOprEntry 1 }
|
|
|
|
hwIsdnPortStateSwitchTestStatus OBJECT-TYPE
|
|
SYNTAX INTEGER{success(1),failure(2),portBusy(3),timeOut(4),testingAbnormal(5)}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Test status.
|
|
Options:
|
|
1. success(1) -indicates normal
|
|
2. failure(2) -indicates abnormal
|
|
3. portBusy(3) -indicates busy port
|
|
4. timeOut(4) -indicates timed-out
|
|
5. testingAbnormal(5) -indicates test abnormal
|
|
"
|
|
::= { hwIsdnPortStateSwitchTestOprEntry 2 }
|
|
|
|
hw112UserRingTestOprTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF Hw112UserRingTestOprEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Ringing test on the 112 analog subscriber phones:
|
|
It realizes the function of the ringing test on the phones of subscribers in the system. This test helps check whether a subscriber phone can ring normally.
|
|
The index of this table is ifIndex"
|
|
::= { hwNTestMIBObjects 6 }
|
|
|
|
hw112UserRingTestOprEntry OBJECT-TYPE
|
|
SYNTAX Hw112UserRingTestOprEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Ringing test on the 112 analog subscriber phones:
|
|
It realizes the function of the ringing test on the phones of subscribers in the system. This test helps check whether a subscriber phone can ring normally.
|
|
The index of this entry is ifIndex"
|
|
|
|
INDEX {
|
|
ifIndex
|
|
}
|
|
::= { hw112UserRingTestOprTable 1 }
|
|
|
|
Hw112UserRingTestOprEntry ::=
|
|
SEQUENCE
|
|
{
|
|
hw112UserRingTestOprType INTEGER,
|
|
hw112UserRingTestTime Integer32,
|
|
hw112UserRingTestResult INTEGER
|
|
}
|
|
|
|
hw112UserRingTestOprType OBJECT-TYPE
|
|
SYNTAX INTEGER{stop(1),start(2)}
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Operation type .
|
|
Options:
|
|
1. stop(1) -stop the test
|
|
2. start(2) -start the test
|
|
Note:The 112 protocol does not define the stop command.
|
|
"
|
|
::= { hw112UserRingTestOprEntry 1 }
|
|
|
|
hw112UserRingTestTime OBJECT-TYPE
|
|
SYNTAX Integer32(3..60)
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Ringing duration.
|
|
Unit: second
|
|
"
|
|
::= { hw112UserRingTestOprEntry 2 }
|
|
|
|
hw112UserRingTestResult OBJECT-TYPE
|
|
SYNTAX INTEGER{offhook(1),onhook(2)}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Test result.
|
|
Options:
|
|
1. offhook(1) -indicates off hook
|
|
2. onhook(2) -indicates on hook
|
|
The 112 protocol defines only two test results."
|
|
::= { hw112UserRingTestOprEntry 3 }
|
|
|
|
hw112UserDialTestOprTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF Hw112UserDialTestOprEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Operation table for the test on the DTMF or pulse feature of the 112 analog subscriber phones:
|
|
It realizes the test on the DTMF or pulse feature of the subscriber phones in the system. This test helps check whether a subscriber phone can make calls normally.
|
|
The index of this table is ifIndex"
|
|
::= { hwNTestMIBObjects 7 }
|
|
|
|
hw112UserDialTestOprEntry OBJECT-TYPE
|
|
SYNTAX Hw112UserDialTestOprEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Operation table for the test on the DTMF or pulse feature of the 112 analog subscriber phones:
|
|
It realizes the test on the DTMF or pulse feature of the subscriber phones in the system. This test helps check whether a subscriber phone can make calls normally.
|
|
The index of this entry is ifIndex"
|
|
INDEX {
|
|
ifIndex
|
|
}
|
|
::= { hw112UserDialTestOprTable 1 }
|
|
|
|
Hw112UserDialTestOprEntry ::=
|
|
SEQUENCE
|
|
{
|
|
hw112UserDialTestOprType INTEGER,
|
|
hw112UserDialTestReceiveNumber Integer32,
|
|
hw112UserDialTestResult INTEGER,
|
|
hw112UserDialTestDigit INTEGER,
|
|
hw112UserDialTestLowLevel Integer32,
|
|
hw112UserDialTestHighLevel Integer32,
|
|
hw112UserDialTestLowFreq Integer32,
|
|
hw112UserDialTestHighFreq Integer32,
|
|
hw112UserDialTestPulseLen Integer32,
|
|
hw112UserDialTestMakeDur Integer32,
|
|
hw112UserDialTestBreakDur Integer32
|
|
}
|
|
|
|
hw112UserDialTestOprType OBJECT-TYPE
|
|
SYNTAX INTEGER{stop(1),start(2)}
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Operation type .
|
|
Options:
|
|
1. stop(1) -stop the test
|
|
2. start(2) -start the test
|
|
Note:The 112 protocol does not define the stop command.
|
|
"
|
|
::= { hw112UserDialTestOprEntry 1 }
|
|
|
|
hw112UserDialTestReceiveNumber OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Number of received calls"
|
|
::= { hw112UserDialTestOprEntry 2 }
|
|
|
|
hw112UserDialTestResult OBJECT-TYPE
|
|
SYNTAX INTEGER{success(1),fail(2)}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Operation result.
|
|
Options:
|
|
1. success(1) -indicates the test is successful
|
|
2. fail(2) -indicates the test fail
|
|
"
|
|
::= { hw112UserDialTestOprEntry 3 }
|
|
|
|
hw112UserDialTestDigit OBJECT-TYPE
|
|
SYNTAX INTEGER{n1(1),n2(2),n3(3),n4(4),n5(5),n6(6),n7(7),n8(8),n9(9),n0(10),nStar(11),nWell(12),nOthers(13),onhook(14)}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Dialing numeral.
|
|
Options:
|
|
1. n1(1) -indicates 1
|
|
2. n2(2) -indicates 2
|
|
3. n3(3) -indicates 3
|
|
4. n4(4) -indicates 4
|
|
5. n5(5) -indicates 5
|
|
6. n6(6) -indicates 6
|
|
7. n7(7) -indicates 7
|
|
8. n8(8) -indicates 8
|
|
9. n9(9) -indicates 9
|
|
10. n0(10) -indicates 0
|
|
11. nStar(11) -indicates *
|
|
12. nWell(12) -indicates #
|
|
13. nOthers(13) -indicates others
|
|
14. onhook(14) -indicates on hook
|
|
"
|
|
::= { hw112UserDialTestOprEntry 4 }
|
|
|
|
hw112UserDialTestLowLevel OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Digital low power level.
|
|
Unit: dBm
|
|
"
|
|
::= { hw112UserDialTestOprEntry 5 }
|
|
|
|
hw112UserDialTestHighLevel OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Digital high power level.
|
|
Unit: dBm
|
|
"
|
|
::= { hw112UserDialTestOprEntry 6 }
|
|
|
|
hw112UserDialTestLowFreq OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Digital low frequency.
|
|
Unit: Hz
|
|
"
|
|
::= { hw112UserDialTestOprEntry 7 }
|
|
|
|
hw112UserDialTestHighFreq OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Digital high frequency.
|
|
Unit: Hz
|
|
"
|
|
::= { hw112UserDialTestOprEntry 8 }
|
|
|
|
hw112UserDialTestPulseLen OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Pulse length.
|
|
Unit: millisecond
|
|
"
|
|
::= { hw112UserDialTestOprEntry 9 }
|
|
|
|
hw112UserDialTestMakeDur OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Pulse duration.
|
|
Unit: millisecond
|
|
"
|
|
::= { hw112UserDialTestOprEntry 10 }
|
|
|
|
hw112UserDialTestBreakDur OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Pulse break length.
|
|
Unit: millisecond
|
|
"
|
|
::= { hw112UserDialTestOprEntry 11 }
|
|
|
|
hw112UserHowlerTestOprrTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF Hw112UserHowlerTestOprrEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Operation table for the howler tone test on 112 analog subscriber phones:
|
|
It realizes the function of the howler tone test on the subscriber phones in the system. This test helps check whether a subscriber phone can play the howler tone normally.
|
|
The index of this table is ifIndex"
|
|
::= { hwNTestMIBObjects 8 }
|
|
|
|
hw112UserHowlerTestOprrEntry OBJECT-TYPE
|
|
SYNTAX Hw112UserHowlerTestOprrEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Operation table for the howler tone test on 112 analog subscriber phones:
|
|
It realizes the function of the howler tone test on the subscriber phones in the system. This test helps check whether a subscriber phone can play the howler tone normally.
|
|
The index of this entry is ifIndex"
|
|
INDEX {
|
|
ifIndex
|
|
}
|
|
::= { hw112UserHowlerTestOprrTable 1 }
|
|
|
|
Hw112UserHowlerTestOprrEntry ::=
|
|
SEQUENCE
|
|
{
|
|
hw112UserHowlerTestOprType INTEGER,
|
|
hw112UserHowlerTestTime Integer32,
|
|
hw112UserHowlerTestResult INTEGER
|
|
}
|
|
|
|
hw112UserHowlerTestOprType OBJECT-TYPE
|
|
SYNTAX INTEGER{stop(1),start(2)}
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Operation type .
|
|
Options:
|
|
1. stop(1) -stop the test
|
|
2. start(2) -start the test
|
|
Note:The 112 protocol does not define the stop command.
|
|
"
|
|
::= { hw112UserHowlerTestOprrEntry 1 }
|
|
|
|
hw112UserHowlerTestTime OBJECT-TYPE
|
|
SYNTAX Integer32(3..180)
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Howler tone length.
|
|
Unit: second
|
|
"
|
|
::= { hw112UserHowlerTestOprrEntry 2 }
|
|
|
|
hw112UserHowlerTestResult OBJECT-TYPE
|
|
SYNTAX INTEGER{offhook(1),onhook(2)}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Operation result.
|
|
Options:
|
|
1. offhook(1) -indicates off hook
|
|
2. onhook(2) -indicates on hook
|
|
The 112 protocol defines only two test results."
|
|
::= { hw112UserHowlerTestOprrEntry 3 }
|
|
|
|
hw112IsdnDiagnoseTestOprTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF Hw112IsdnDiagnoseTestOprEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Operation table for the diagnosis test on the 112 ISDN subscribers:
|
|
It realizes the function of the diagnosis test on the 112 ISDN subscribers in the system. Its test items are the same as the test items of the circuit test on the PSTN subscribers.
|
|
The index of this table is ifIndex"
|
|
::= { hwNTestMIBObjects 9 }
|
|
|
|
hw112IsdnDiagnoseTestOprEntry OBJECT-TYPE
|
|
SYNTAX Hw112IsdnDiagnoseTestOprEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Operation table for the diagnosis test on the 112 ISDN subscribers:
|
|
It realizes the function of the diagnosis test on the 112 ISDN subscribers in the system. Its test items are the same as the test items of the circuit test on the PSTN subscribers.
|
|
The index of this entry is ifIndex"
|
|
INDEX {
|
|
ifIndex
|
|
}
|
|
::= { hw112IsdnDiagnoseTestOprTable 1 }
|
|
|
|
Hw112IsdnDiagnoseTestOprEntry ::=
|
|
SEQUENCE
|
|
{
|
|
hw112IsdnDiagnoseTestOprType INTEGER,
|
|
hw112IsdnDiagnoseTestLoopType INTEGER,
|
|
hw112IsdnDiagnoseTestLoopChannel INTEGER,
|
|
hw112IsdnDiagnoseTestResult INTEGER,
|
|
hw112IsdnDiagnoseTestLoopTime Integer32,
|
|
hw112IsdnDiagnoseTestLoopDirection INTEGER ,
|
|
hw112IsdnDiagnoseTestLoopTs Integer32,
|
|
hw112IsdnDiagnoseTestDeferredTestFlag INTEGER,
|
|
hw112IsdnDiagnoseTestDeferredTime Integer32,
|
|
hw112IsdnDiagnoseTestTimeoutProc INTEGER,
|
|
hw112IsdnDiagnoseTestIfIndex Integer32,
|
|
hw112IsdnDiagnoseTestRequestID Integer32
|
|
}
|
|
|
|
hw112IsdnDiagnoseTestOprType OBJECT-TYPE
|
|
SYNTAX INTEGER{start(1),stop(2)}
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Operation type .
|
|
Options:
|
|
1. start(1) -start the test
|
|
2. stop(2) -stop the test
|
|
Note:The 112 protocol does not define the stop command.
|
|
"
|
|
::= { hw112IsdnDiagnoseTestOprEntry 1 }
|
|
|
|
hw112IsdnDiagnoseTestLoopType OBJECT-TYPE
|
|
SYNTAX INTEGER{nt1(1),ltet(2)}
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Loopback type.
|
|
Options:
|
|
1. nt1(1) -indicates NT1
|
|
2. ltet(2) -indicates LT/ET
|
|
"
|
|
::= { hw112IsdnDiagnoseTestOprEntry 2 }
|
|
|
|
hw112IsdnDiagnoseTestLoopChannel OBJECT-TYPE
|
|
SYNTAX INTEGER{bOne(1),bTwo(2),twoBAndD(3),pra(4)}
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Loopback .
|
|
Options:
|
|
1. bOne(1) -indicates B1
|
|
2. bTwo(2) -indicates B2
|
|
3. twoBAndD(3) -indicates 2B+D
|
|
4. pra(4) -indicates PRA
|
|
"
|
|
::= { hw112IsdnDiagnoseTestOprEntry 3 }
|
|
|
|
hw112IsdnDiagnoseTestResult OBJECT-TYPE
|
|
SYNTAX INTEGER{success(1),failure(2),timeoutsuccess(3),exceptionstop(4),testcanceled(5)}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Operation result.
|
|
Options:
|
|
1. success(1) -indicates loopback success, and user stop the test manually;
|
|
2. failure(2) -indicates loopback failure;
|
|
3. timeoutsuccess(3) -indicates loopback success, and loop time out.
|
|
4. exceptionstop(4) -indicates exception occur;
|
|
5. testcanceled(5) -indicates loopback test is not performed, and test is canceled by user or deferred time out"
|
|
::= { hw112IsdnDiagnoseTestOprEntry 4 }
|
|
|
|
|
|
hw112IsdnDiagnoseTestLoopTime OBJECT-TYPE
|
|
SYNTAX Integer32(1..1440)
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
Loop time.
|
|
Unit: minute
|
|
"
|
|
DEFVAL { 15 }
|
|
::= { hw112IsdnDiagnoseTestOprEntry 5 }
|
|
|
|
hw112IsdnDiagnoseTestLoopDirection OBJECT-TYPE
|
|
SYNTAX INTEGER{nearloop(1),farloop(2)}
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
Loop direction.
|
|
Options:
|
|
1. nearloop(1) -indicates loop direction is near loop
|
|
2. farloop(2) -indicates loop direction is far loop
|
|
"
|
|
::= { hw112IsdnDiagnoseTestOprEntry 6 }
|
|
|
|
hw112IsdnDiagnoseTestLoopTs OBJECT-TYPE
|
|
SYNTAX Integer32(0..31)
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
Time slot to be looped back
|
|
"
|
|
::= { hw112IsdnDiagnoseTestOprEntry 7 }
|
|
|
|
|
|
hw112IsdnDiagnoseTestDeferredTestFlag OBJECT-TYPE
|
|
SYNTAX INTEGER{immediatetest(1),deferredtest(2)}
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
deferred test flag:
|
|
Options:
|
|
1. immediatetest(1) -immediate test;
|
|
2. deferredtest(2) -indicates deferred test: Initiated when the port is in service. If the port is busy, the test operation
|
|
will be deferred. If the port changes to idle state before time out, the test will be executed
|
|
immediately. If the port keeps busy by the time out, the system will excecute a corresponding
|
|
operation according to what the user specified: canceling the test or forcing to test.
|
|
If the value of this leaf node is deferredtest(2), both hw112IsdnDiagnoseTestDeferredTime and
|
|
hw112IsdnDiagnoseTestTimeoutProc must be set.
|
|
Default: immediatetest(1).
|
|
"
|
|
DEFVAL { 1 }
|
|
::= { hw112IsdnDiagnoseTestOprEntry 8 }
|
|
|
|
hw112IsdnDiagnoseTestDeferredTime OBJECT-TYPE
|
|
SYNTAX Integer32(1..1440)
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
Deferred time(unit: minute):
|
|
this leaf node is valid only when the value of hw112IsdnDiagnoseTestDeferredTestFlag is deferredtest(2).
|
|
Default: 30(minute).
|
|
"
|
|
DEFVAL { 30 }
|
|
::= { hw112IsdnDiagnoseTestOprEntry 9 }
|
|
|
|
hw112IsdnDiagnoseTestTimeoutProc OBJECT-TYPE
|
|
SYNTAX INTEGER{notest(1),test(2)}
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
Options:
|
|
1. notest(1) -no test is applied
|
|
2. test(2) -a test is applied
|
|
Timeout proc:
|
|
1-when deferred time out, if the port is still in service, test will be canceled;
|
|
2-when deferred time out, if the port is still in service, test will be preformed by force.
|
|
this leaf node is valid only when the value of hw112IsdnDiagnoseTestDeferredTestFlag is deferredtest(2).
|
|
Default: notest(1).
|
|
"
|
|
DEFVAL { 1 }
|
|
::= { hw112IsdnDiagnoseTestOprEntry 10 }
|
|
|
|
hw112IsdnDiagnoseTestIfIndex OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
Port IfIndex
|
|
"
|
|
::= { hw112IsdnDiagnoseTestOprEntry 11 }
|
|
|
|
hw112IsdnDiagnoseTestRequestID OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
Request ID
|
|
"
|
|
::= { hw112IsdnDiagnoseTestOprEntry 12 }
|
|
|
|
hwPstnCallerEmulateOprTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF HwPstnCallerEmulateOprEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Operation table for the PSTN call emulation test (calling party):
|
|
It realizes the function of the call emulation test (caller dial) in the system. This test helps check whether a subscriber port can make calls normally as a calling party.
|
|
The index of this table is ifIndex."
|
|
::= { hwNTestMIBObjects 10 }
|
|
|
|
hwPstnCallerEmulateOprEntry OBJECT-TYPE
|
|
SYNTAX HwPstnCallerEmulateOprEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Operation table for the PSTN call emulation test (calling party):
|
|
It realizes the function of the call emulation test (caller dial) in the system. This test helps check whether a subscriber port can make calls normally as a calling party.
|
|
The index of this entry is ifIndex."
|
|
INDEX {
|
|
ifIndex
|
|
}
|
|
::= { hwPstnCallerEmulateOprTable 1 }
|
|
|
|
HwPstnCallerEmulateOprEntry ::=
|
|
SEQUENCE
|
|
{
|
|
hwPstnCallerEmulateOprType INTEGER,
|
|
hwPstnCallerEmulateCalledTelNo OCTET STRING,
|
|
hwPstnCallerEmulateDialMode INTEGER,
|
|
hwPstnCallerEmulateTestStatus INTEGER,
|
|
hwPstnCallerEmulateTestResult INTEGER,
|
|
hwPstnCallerEmulateTestDTMFDetected OCTET STRING,
|
|
hwPstnCallerEmulateTestHoldTime Unsigned32,
|
|
hwPstnCallerEmulateReportNumber OCTET STRING,
|
|
hwPstnCallerEmulateLocalErrorCode Unsigned32,
|
|
hwPstnCallerEmulateRemoteErrorCode Unsigned32,
|
|
hwPstnCallerEmulateTestRequestID Unsigned32
|
|
}
|
|
|
|
hwPstnCallerEmulateOprType OBJECT-TYPE
|
|
SYNTAX INTEGER{stop(1),start(2),offHookConfirm(3), sendDTMF(4)}
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Operation type.
|
|
Options:
|
|
1: stop(1) -indicates Stop test
|
|
2: start(2) -indicates Start test
|
|
3: offHookConfirm(3) -indicates Off hook confirmation
|
|
4: sendDTMF(4) -indicates Send DTMF
|
|
"
|
|
::= { hwPstnCallerEmulateOprEntry 1 }
|
|
|
|
hwPstnCallerEmulateCalledTelNo OBJECT-TYPE
|
|
SYNTAX OCTET STRING(SIZE(32))
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Called telephone number (max length: 32)"
|
|
::= { hwPstnCallerEmulateOprEntry 2 }
|
|
|
|
hwPstnCallerEmulateDialMode OBJECT-TYPE
|
|
SYNTAX INTEGER{dtmf(1), pulse(2)}
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Dial type (Enumerated type.)
|
|
Options:
|
|
1. dtmf(1) -indicates the dial mode is DTMF
|
|
2. pulse(2) -indicates the dial mode is pulse
|
|
"
|
|
::= { hwPstnCallerEmulateOprEntry 3 }
|
|
|
|
hwPstnCallerEmulateTestStatus OBJECT-TYPE
|
|
SYNTAX INTEGER{startSuccessfully(1),stopSuccessfully(2), sendDTMFSuccessfully(3), testOuttime(4), noDialtone(5), callerDialNumberAlready(6), noRinging(7), noRingbackTone(8), waitingAgentMessageOuttime(9), testingFailure(10), agentMessageAck(11),calledoffhook(12),testingAbnormal(13),broadbandtesting(14),capturefail(15),notratb(16),configsuccessfully(17), ring(18), calleroffhook(19), playdialtone(20), receiving(21), dialnumbercomplete(22), ringingbacktone(23), talking(24), testfinished(28)}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Test Status.
|
|
Options:
|
|
1. startSuccessfully(1) -indicates start successfully
|
|
2. stopSuccessfully(2) -indicates stop successfully
|
|
3. sendDTMFSuccessfully(3) -indicates send DTMF successfully
|
|
4. testOuttime(4) -indicates timed-out;
|
|
5. noDialtone(5) -indicates no dial tone
|
|
6. callerDialNumberAlready(6) -indicates caller already dials a number
|
|
7. noRinging(7) -indicates no ringing
|
|
8. noRingbackTone(8) -indicates no ring-back tone
|
|
9. waitingAgentMessageOuttime(9) -indicates timed-out (waiting for EMS processing)
|
|
10.testingFailure(10) -indicates test failure
|
|
11.agentMessageAck(11) -indicates host responds to the EMS
|
|
12.calledoffhook(12) -indicates off hook (called party)
|
|
13.testingAbnormal(13) -indicates test abnormal;
|
|
14.broadbandtesting(14) -indicates broadband testing
|
|
15.capturefail(15) -indicates line capture failure
|
|
16.notratb(16) -indicates relay transfer board does not exist
|
|
17.configsuccessfully(17) -indicates configured successfully
|
|
18.ring(18) -indicates ringing
|
|
19.calleroffhook(19) -indicates off hook (calling party)
|
|
20.playdialtone(20) -indicates play the dial tone
|
|
21.receiving(21) -indicates receiving
|
|
22.dialnumbercomplete(22) -indicates dialup is finished
|
|
23.ringingbacktone(23) -indicates ringing back tone
|
|
24.talking(24) -indicates talking
|
|
25.testfinished(28) -indicates the test is over
|
|
"
|
|
::= { hwPstnCallerEmulateOprEntry 4 }
|
|
|
|
hwPstnCallerEmulateTestResult OBJECT-TYPE
|
|
SYNTAX INTEGER{callerNoDialTone(1), callerOffHookingBusy(2), callerDialingBusy(3), callerNoDial(4), callerDialedBusy(5), callerDialedNoTalk(6), callRelease(7), matchNoCompleted(8), sendNoCompleted(9), testSucceed(10), callerMatchFailed(11), callerPortAbnormal(12)}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Emulational Caller Test Result
|
|
Options:
|
|
1. callerNoDialTone(1) -indicates the caller does not have dial tone
|
|
2. callerOffHookingBusy(2) -indicates the caller is busy in off-hooking
|
|
3. callerDialingBusy(3) -indicates the caller is busy in dialing
|
|
4. callerNoDial(4) -indicates the caller does not dial
|
|
5. callerDialedBusy(5) -indicates the caller is busy in dialed
|
|
6. callerDialedNoTalk(6) -indicates the caller has already dialed but has not connected
|
|
7. callRelease(7) -indicates the call is released
|
|
8. matchNoCompleted(8) -indicates the match is not completed
|
|
9. sendNoCompleted(9) -indicates the sending is not completed
|
|
10.testSucceed(10) -indicates the test succeed
|
|
11.callerMatchFailed(11) -indicates the caller match failed
|
|
12.callerPortAbnormal(12) -indicates the caller's port is abnormal
|
|
"
|
|
::= { hwPstnCallerEmulateOprEntry 5 }
|
|
|
|
hwPstnCallerEmulateTestDTMFDetected OBJECT-TYPE
|
|
SYNTAX OCTET STRING(SIZE(64))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Detected Dtmf Num List"
|
|
::= { hwPstnCallerEmulateOprEntry 6 }
|
|
|
|
hwPstnCallerEmulateTestHoldTime OBJECT-TYPE
|
|
SYNTAX Unsigned32(5..600)
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
Caller Emulate test hold time, the test will auto ended when this time out.
|
|
"
|
|
DEFVAL {4294967295}
|
|
::= { hwPstnCallerEmulateOprEntry 7 }
|
|
|
|
hwPstnCallerEmulateReportNumber OBJECT-TYPE
|
|
SYNTAX OCTET STRING(SIZE(32))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The actual called number string checked and send to MGC or IMS."
|
|
::= { hwPstnCallerEmulateOprEntry 8 }
|
|
|
|
hwPstnCallerEmulateLocalErrorCode OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Error code send by Local side."
|
|
::= { hwPstnCallerEmulateOprEntry 9 }
|
|
|
|
hwPstnCallerEmulateRemoteErrorCode OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Error code received from remote side."
|
|
::= { hwPstnCallerEmulateOprEntry 10 }
|
|
|
|
hwPstnCallerEmulateTestRequestID OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Request ID"
|
|
::= { hwPstnCallerEmulateOprEntry 11 }
|
|
|
|
hwPstnCalledEmulateOprTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF HwPstnCalledEmulateOprEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The operation table of the caller test of the PSTN call emulation test. It is used to realize the caller
|
|
test of the PSTN call emulation test, which is used to test whether a user of a port functioned as the
|
|
caller can make a call.
|
|
Operation table for the PSTN call emulation test (called party):
|
|
It realizes the function of the call emulation test (called party) in the system. This test helps check whether a subscriber port can make calls normally as a called party.
|
|
The index of this table is ifIndex"
|
|
::= { hwNTestMIBObjects 11 }
|
|
|
|
hwPstnCalledEmulateOprEntry OBJECT-TYPE
|
|
SYNTAX HwPstnCalledEmulateOprEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The operation table of the caller test of the PSTN call emulation test. It is used to realize the caller
|
|
test of the PSTN call emulation test, which is used to test whether a user of a port functioned as the
|
|
caller can make a call.
|
|
Operation table for the PSTN call emulation test (called party):
|
|
It realizes the function of the call emulation test (called party) in the system. This test helps check whether a subscriber port can make calls normally as a called party.
|
|
The index of this entry is ifIndex"
|
|
INDEX {
|
|
ifIndex
|
|
}
|
|
::= { hwPstnCalledEmulateOprTable 1 }
|
|
|
|
HwPstnCalledEmulateOprEntry ::=
|
|
SEQUENCE
|
|
{
|
|
hwPstnCalledEmulateOprType INTEGER,
|
|
hwPstnCalledEmulateTestStatus INTEGER,
|
|
hwPstnCalledEmulateTestResult INTEGER,
|
|
hwPstnCalledEmulateTestDTMFDetected OCTET STRING,
|
|
hwPstnCalledEmulateTestWaitTime Unsigned32,
|
|
hwPstnCalledEmulateTestHoldTime Unsigned32,
|
|
hwPstnCalledEmulateLocalErrorCode Unsigned32,
|
|
hwPstnCalledEmulateRemoteErrorCode Unsigned32,
|
|
hwPstnCalledEmulateTestRequestID Unsigned32
|
|
}
|
|
|
|
hwPstnCalledEmulateOprType OBJECT-TYPE
|
|
SYNTAX INTEGER{stop(1),start(2), dialConfirm(3), sendDTMF(4), config(5)}
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Operation type.
|
|
Options:
|
|
1. stop(1) -indicates Stop test
|
|
2. start(2) -indicates Start test
|
|
3. dialConfirm(3) -indicates Dial number confirmation
|
|
4. sendDTMF(4) -indicates Send DTMF
|
|
5. config(5) -indicates Configuration test
|
|
"
|
|
::= { hwPstnCalledEmulateOprEntry 1 }
|
|
|
|
hwPstnCalledEmulateTestStatus OBJECT-TYPE
|
|
SYNTAX INTEGER{startSuccessfully(1),stopSuccessfully(2), sendDTMFSuccessfully(3), testOuttime(4), noDialtone(5), callerDialNumberAlready(6),noRinging(7), noRingbackTone(8), waitingAgentMessageOuttime(9), testingFailure(10), agentMessageAck(11),calledoffhook(12),testingAbnormal(13),broadbandtesting(14),capturefail(15),notratb(16),configsuccessfully(17),ring(18),calleroffhook(19),playdialtone(20),dialnumbercomplete(21), testfinished(23)}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Test Status.
|
|
Options:
|
|
1. startSuccessfully(1) -indicates start successfully
|
|
2. stopSuccessfully(2) -indicates stop successfully
|
|
3. sendDTMFSuccessfully(3) -indicates send DTMF successfully
|
|
4. testOuttime(4) -indicates timed-out;
|
|
5. noDialtone(5) -indicates no dial tone
|
|
6. callerDialNumberAlready(6) -indicates caller already dials a number
|
|
7. noRinging(7) -indicates no ringing
|
|
8. noRingbackTone(8) -indicates no ring-back tone;
|
|
9. waitingAgentMessageOuttime(9)-indicates timed-out (waiting for EMS processing)
|
|
10.testingFailure(10) -indicates test failure
|
|
11.agentMessageAck(11) -indicates host responds to the EMS
|
|
12.calledoffhook(12) -indicates off hook (called party)
|
|
13.testingAbnormal(13) -indicates test abnormal;
|
|
14.broadbandtesting(14) -indicates broadband testing
|
|
15.capturefail(15) -indicates line capture failure
|
|
16.notratb(16) -indicates transfer board does not exist
|
|
17.configsuccessfully(17) -indicates configured successfully
|
|
18.ring(18) -indicates ringing
|
|
19.calleroffhook(19) -indicates off hook (calling party)
|
|
20.playdialtone(20) -indicates play the dial tone
|
|
21.dialnumbercomplete(21) -indicates dialup is finished
|
|
22.testfinished(23) -indicates the test is over
|
|
"
|
|
::= { hwPstnCalledEmulateOprEntry 2 }
|
|
|
|
hwPstnCalledEmulateTestResult OBJECT-TYPE
|
|
SYNTAX INTEGER{calledNoRing(1), calledNoOffHook(2), calledOffHookingBusy(3), calledNoTalk(4), callRelease(5), matchNoCompleted(6), sendNoCompleted(7), testSucceed(8), calledMatchFailed(9), calledPortAbnormal(10)}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Emulational Called Test Result
|
|
Options:
|
|
1. calledNoRing(1) -indicates the called user dose not ring
|
|
2. calledNoOffHook(2) -indicates the called user dose not off hook
|
|
3. calledOffHookingBusy(3) -indicates the called user is busy in off-hooking
|
|
4. calledNoTalk(4) -indicates the called user does not connect
|
|
5. callRelease(5) -indicates the call is released
|
|
6. matchNoCompleted(6) -indicates the match is not completed
|
|
7. sendNoCompleted(7) -indicates the sending is not completed
|
|
8. testSucceed(8) -indicates the test succeed
|
|
9. calledMatchFailed(9) -indicates the called user match failed
|
|
10.calledPortAbnormal(10) -indicates the called port is abnormal
|
|
"
|
|
::= { hwPstnCalledEmulateOprEntry 3 }
|
|
|
|
hwPstnCalledEmulateTestDTMFDetected OBJECT-TYPE
|
|
SYNTAX OCTET STRING(SIZE(64))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Detected Dtmf Num List"
|
|
::= { hwPstnCalledEmulateOprEntry 4 }
|
|
|
|
hwPstnCalledEmulateTestWaitTime OBJECT-TYPE
|
|
SYNTAX Unsigned32(5..600)
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
Called Emulate test waiting time, the test will auto failed when this time out and called port not received ring.
|
|
"
|
|
DEFVAL {4294967295}
|
|
::= { hwPstnCalledEmulateOprEntry 5 }
|
|
|
|
|
|
hwPstnCalledEmulateTestHoldTime OBJECT-TYPE
|
|
SYNTAX Unsigned32(5..600)
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
Called Emulate test hold time, the test will auto ended when this time out.
|
|
"
|
|
DEFVAL {4294967295}
|
|
::= { hwPstnCalledEmulateOprEntry 6 }
|
|
|
|
hwPstnCalledEmulateLocalErrorCode OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Error code send by Local side."
|
|
::= { hwPstnCalledEmulateOprEntry 7}
|
|
|
|
hwPstnCalledEmulateRemoteErrorCode OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
Error code received from remote side.
|
|
"
|
|
::= { hwPstnCalledEmulateOprEntry 8 }
|
|
|
|
hwPstnCalledEmulateTestRequestID OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Request ID"
|
|
::= { hwPstnCalledEmulateOprEntry 9 }
|
|
|
|
hwPstnTelephoneTestOprTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF HwPstnTelephoneTestOprEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
The operation table of the called test of the PSTN call emulation test. It is used to realize the called
|
|
test of the PSTN call emulation test, which is used to test whether a user of a port functioned as the
|
|
called party can make a call.
|
|
The index of this table is ifIndex.
|
|
Operation table for the PSTN telephone test:
|
|
It realizes the function of the test on subscriber phones in the system. This test helps test the features of the subscriber phone and check whether a subscriber phone works in the normal state."
|
|
::= { hwNTestMIBObjects 12 }
|
|
|
|
hwPstnTelephoneTestOprEntry OBJECT-TYPE
|
|
SYNTAX HwPstnTelephoneTestOprEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
The operation table of the called test of the PSTN call emulation test. It is used to realize the called
|
|
test of the PSTN call emulation test, which is used to test whether a user of a port functioned as the
|
|
called party can make a call.
|
|
The index of this entry is ifIndex.
|
|
Operation table for the PSTN telephone test:
|
|
It realizes the function of the test on subscriber phones in the system. This test helps test the features of the subscriber phone and check whether a subscriber phone works in the normal state."
|
|
INDEX {
|
|
ifIndex
|
|
}
|
|
::= { hwPstnTelephoneTestOprTable 1 }
|
|
|
|
HwPstnTelephoneTestOprEntry ::=
|
|
SEQUENCE
|
|
{
|
|
hwPstnTelephoneTestOprType INTEGER,
|
|
hwPstnTelephoneTestStatus INTEGER,
|
|
hwPstnTelephoneTestLoopResist Integer32,
|
|
hwPstnTelephoneTestHookingTime Integer32,
|
|
hwPstnTelephoneTestReverse INTEGER,
|
|
hwPstnTelephoneTestDialDigit INTEGER,
|
|
hwPstnTelephoneTestPulseLen Integer32,
|
|
hwPstnTelephoneTestMakeDur Integer32,
|
|
hwPstnTelephoneTestBreakDur Integer32,
|
|
hwPstnTelephoneTestAssisTelno OCTET STRING,
|
|
hwPstnTelephoneTestRingTime Integer32
|
|
}
|
|
|
|
hwPstnTelephoneTestOprType OBJECT-TYPE
|
|
SYNTAX INTEGER{stop(1), start(2), ringing(3), stopRinging(4), recieveNumber(5), stopRecievingNumber(6), poleTest(7), loopResistance(8),
|
|
busyTone(9), stopBusyTone(10), howlTone(11), stopHowlTone(12), flash(13), stopFlash(14)}
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Operation type.
|
|
Options:
|
|
1. stop(1) -indicates Stop test
|
|
2. start(2) -indicates Start test
|
|
3. ringing(3) -indicates Ring
|
|
4. stopRinging(4) -indicates Stop ringing
|
|
5. recieveNumber(5) -indicates Receive a number
|
|
6. stopRecievingNumber(6) -indicates Stop receiving a number
|
|
7. poleTest(7) -indicates Reverse polarity
|
|
8. loopResistance(8) -indicates Test the loop resistance
|
|
9. busyTone(9) -indicates Send the interrupted tone
|
|
10.stopBusyTone(10) -indicates Stop sending the interrupted tone
|
|
11.howlTone(11) -indicates Send the continuous tone
|
|
12.stopHowlTone(12) -indicates Stop sending the continuous tone
|
|
13.flash(13) -indicates Receive hookflash
|
|
14.stopFlash(14) -indicates Stop receiving hookflash
|
|
"
|
|
::= { hwPstnTelephoneTestOprEntry 1 }
|
|
|
|
hwPstnTelephoneTestStatus OBJECT-TYPE
|
|
SYNTAX INTEGER{startSuccessfully(1),stopSuccessfully(2), testOuttime(3), asisportringing(4),detectRingingOuttime(5),waitingOffHookouttime(6), waitingoffHook(7), testingFailure(8), onHook(9), offHook(10), ringingSuccessful(11), stopRingingSuccessfully(12),startToRecieveDigit(13),stopRevievingDigitSuccessfully(14),sendBusyToneSuccessfully(15),stopBusyToneSuccessfully(16),sendHowlToneSuccessfully(17),stopHowlToneSuccessfully(18),startToRecieveFlash(19),stopRevFlashSuccessfully(20),waitHTcmdTimeout(21),reporttestreport(22),testingAbnormal(23),broadbandtesting(29),capturefail(30),notratb(31),ringtimeout(32)}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Test status.
|
|
Options:
|
|
1. startSuccessfully(1) -indicates Start test successfully
|
|
2. stopSuccessfully(2) -indicates Stop test successfully
|
|
3. testOuttime(3) -indicates Timed-out (test)
|
|
4. asisportringing(4) -indicates Assistance port ringing
|
|
5. detectRingingOuttime(5) -indicates Timed-out (detecting the assistance port ringing)
|
|
6. waitingOffHookouttime(6) -indicates Timed-out (waiting for off-hook)
|
|
7. waitingoffHook(7) -indicates Waiting for off-hook
|
|
8. testingFailure(8) -indicates Test failure;
|
|
9. onHook(9) -indicates On hook
|
|
10. offHook(10) -indicates Off hook
|
|
11. ringingSuccessful(11) -indicates Ring successful
|
|
12. stopRingingSuccessfully(12) -indicates Stop ringing successfully
|
|
13. startToRecieveDigit(13) -indicates Receive a number
|
|
14. stopRevievingDigitSuccessfully(14) -indicates Stop receiving a number successfully
|
|
15. sendBusyToneSuccessfully(15) -indicates Send the interrupted tone successfully
|
|
16. stopBusyToneSuccessfully(16) -indicates Stop sending the interrupted tone successfully;
|
|
17. sendHowlToneSuccessfully(17) -indicates Send the continuous tone successfully
|
|
18. stopHowlToneSuccessfully(18) -indicates Stop sending the continuous tone successfully
|
|
19. startToRecieveFlash(19) -indicates Receive hookflash
|
|
20. stopRevFlashSuccessfully(20) -indicates Stop receiving hookflash
|
|
21. waitHTcmdTimeout(21) -indicates Timed-out (waiting for subscriber processing)
|
|
22. reporttestreport(22) -indicates Report the test result
|
|
23. testingAbnormal(23) -indicates Test abnormal;
|
|
24. broadbandtesting(29) -indicates Broadband testing
|
|
25. capturefail(30) -indicates Line capture failure
|
|
26. notratb(31) -indicates Relay transfer board does not exist
|
|
27. ringtimeout(32) -indicates Ring timeout
|
|
"
|
|
::= { hwPstnTelephoneTestOprEntry 2 }
|
|
|
|
hwPstnTelephoneTestLoopResist OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Loop resistance.
|
|
Unit: ohm
|
|
"
|
|
::= { hwPstnTelephoneTestOprEntry 3 }
|
|
|
|
hwPstnTelephoneTestHookingTime OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Hookflash time.
|
|
Unit: millisecond
|
|
"
|
|
::= { hwPstnTelephoneTestOprEntry 4 }
|
|
|
|
hwPstnTelephoneTestReverse OBJECT-TYPE
|
|
SYNTAX INTEGER{aPositiveAndbNegative(1),aNegativeAndbPositive(2), noFeedVoltage(3),reverseTestOver(4)}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Polarity reversal .
|
|
Options:
|
|
1: aPositiveAndbNegative(1) -indicates A+ B-
|
|
2: aNegativeAndbPositive(2) -indicates A- B+
|
|
3: noFeedVoltage(3) -indicates No feeding voltage
|
|
4: reverseTestOver(4) -indicates Polarity reversal test is finished
|
|
"
|
|
::= { hwPstnTelephoneTestOprEntry 5 }
|
|
|
|
hwPstnTelephoneTestDialDigit OBJECT-TYPE
|
|
SYNTAX INTEGER{n1(1),n2(2),n3(3),n4(4),n5(5),n6(6),n7(7),n8(8),n9(9),n0(10),nStar(11),nWell(12),nOthers(13)}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Dialing numeral
|
|
Options:
|
|
1. n1(1) -indicates 1
|
|
2. n2(2) -indicates 2
|
|
3. n3(3) -indicates 3
|
|
4. n4(4) -indicates 4
|
|
5. n5(5) -indicates 5
|
|
6. n6(6) -indicates 6
|
|
7. n7(7) -indicates 7
|
|
8. n8(8) -indicates 8
|
|
9. n9(9) -indicates 9
|
|
10.n0(10) -indicates 0
|
|
11.nStar(11) -indicates *
|
|
12.nWell(12) -indicates #
|
|
13.nOthers(13) -indicates others;
|
|
"
|
|
::= { hwPstnTelephoneTestOprEntry 6 }
|
|
|
|
hwPstnTelephoneTestPulseLen OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Pulse length.
|
|
Unit: millisecond
|
|
"
|
|
::= { hwPstnTelephoneTestOprEntry 7 }
|
|
|
|
hwPstnTelephoneTestMakeDur OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Pulse duration.
|
|
Unit: millisecond
|
|
"
|
|
::= { hwPstnTelephoneTestOprEntry 8 }
|
|
|
|
hwPstnTelephoneTestBreakDur OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Pulse break length.
|
|
Unit: millisecond
|
|
"
|
|
::= { hwPstnTelephoneTestOprEntry 9 }
|
|
|
|
hwPstnTelephoneTestAssisTelno OBJECT-TYPE
|
|
SYNTAX OCTET STRING(SIZE(16))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Telephone number of the assistant port (the host sends the number to the EMS when the telephone test starts)"
|
|
::= { hwPstnTelephoneTestOprEntry 10 }
|
|
|
|
hwPstnTelephoneTestRingTime OBJECT-TYPE
|
|
SYNTAX Integer32(0..360)
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Ring time.
|
|
Unit: second
|
|
"
|
|
::= { hwPstnTelephoneTestOprEntry 11 }
|
|
|
|
hwIsdnUserDiagnoseTestOprTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF HwIsdnUserDiagnoseTestOprEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Operation table for the diagnosis test on the ISDN subscribers:
|
|
It realizes the diagnosis test on the ISDN subscribers in the system. This test helps check the status and performance of the NT1 and transmission channel.
|
|
The index of this table is ifIndex"
|
|
::= { hwNTestMIBObjects 13 }
|
|
|
|
hwIsdnUserDiagnoseTestOprEntry OBJECT-TYPE
|
|
SYNTAX HwIsdnUserDiagnoseTestOprEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Operation table for the diagnosis test on the ISDN subscribers:
|
|
It realizes the diagnosis test on the ISDN subscribers in the system. This test helps check the status and performance of the NT1 and transmission channel.
|
|
The index of this entry is ifIndex"
|
|
INDEX {
|
|
ifIndex
|
|
}
|
|
::= { hwIsdnUserDiagnoseTestOprTable 1 }
|
|
|
|
HwIsdnUserDiagnoseTestOprEntry ::=
|
|
SEQUENCE
|
|
{
|
|
hwIsdnUserDiagnoseTestOprType INTEGER,
|
|
hwIsdnUserDiagnoseTestStatus INTEGER
|
|
}
|
|
|
|
hwIsdnUserDiagnoseTestOprType OBJECT-TYPE
|
|
SYNTAX INTEGER{activate(1), deactivate(2), bbdLoopbackFromNT1(3), b1LoopbackFromNT1(4), b2LoopbackFromNT1(5), depravingCRCRequest(6),
|
|
depravingCRCAck(7),holdingState(8), restore(9), nT1PowerState(10), loopback1(11), cancelLoopback1(12), stopTest(13),
|
|
loopback4(14), cancelloopback4(15), sendCCRC(16), stopSendCCRC(17), testingAbnormal(18)}
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Operation type.
|
|
Options:
|
|
1: activate(1) -indicates Activate
|
|
2: deactivate(2) -indicates Deactivate
|
|
3: bbdLoopbackFromNT1(3) -indicates 2B+D loopback on NT1
|
|
4: b1LoopbackFromNT1(4) -indicates B1 loopback on NT1
|
|
5: b2LoopbackFromNT1(5) -indicates B1 loopback on NT1
|
|
6: depravingCRCRequest(6) -indicates Bad CRC request
|
|
7: depravingCRCAck(7) -indicates Bad CRC notification
|
|
8: holdingState(8) -indicates State-retaining
|
|
9: restore(9) -indicates Return to normal
|
|
10: nT1PowerState(10) -indicates NT1 power status
|
|
11: loopback1(11) -indicates Loopback1
|
|
12: cancelLoopback1(12) -indicates Cancel loopback1
|
|
13: stopTest(13) -indicates Stop the diagnosis test
|
|
14: loopback4(14) -indicates Loopback4
|
|
15: cancelloopback4(15) -indicates Cancel loopback4
|
|
16: sendCCRC(16) -indicates Send CCRC
|
|
17: stopSendCCRC(17) -indicates Stop sending CCRC
|
|
18: testingAbnormal(18) -indicates Test abnormal
|
|
"
|
|
::= { hwIsdnUserDiagnoseTestOprEntry 1 }
|
|
|
|
hwIsdnUserDiagnoseTestStatus OBJECT-TYPE
|
|
SYNTAX INTEGER{startSuccessfully(1),stopSuccessfully(2),testingNormal(3),actUIfouttime(4),dslDeactOrCancelLoop(5),actUIfFailed(6),normalMasterPowerAbnormalStandbyPowerAbnormal(7),normalMasterPowerNormalStandbyPowerAbnormal(8),normalMasterPowerAbNormalStandbyPowerNormal(9),normalMasterPowerNormalStandbyPowerNormal(10),singleTestingOutTime(11),singleTestingFailure(12),outtime(13),dslReportFailure(14),notTesting(15),testingAbnormal(16)}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Test status.
|
|
Options:
|
|
1: startSuccessfully(1) -indicates Start test successfully (the EMS can activate or loop back a port without starting the test)
|
|
2: stopSuccessfully(2) -indicates Stop test successfully
|
|
3: testingNormal(3) -indicates Test normal
|
|
4: actUIfouttime(4) -indicates Timed-out (activating the U interface)
|
|
5: dslDeactOrCancelLoop(5) -indicates Deactivate the DSL report/cancel loopback1 (the EMS may receive this message when the EMS does not deliver the activate or loopback command)
|
|
6: actUIfFailed(6) -indicates Activating the U interface fails
|
|
7: normalMasterPowerAbnormalStandbyPowerAbnormal(7)-indicates Normal, the primary power does not work, and the standby power does not work
|
|
8: normalMasterPowerNormalStandbyPowerAbnormal(8) -indicates Normal, the primary power works, and the standby power does not work
|
|
9: normalMasterPowerAbNormalStandbyPowerNormal(9) -indicates Normal, the primary power does not work, and the standby power works
|
|
10: normalMasterPowerNormalStandbyPowerNormal(10) -indicates Normal, the primary power works, and the standby power works;
|
|
11: singleTestingOutTime(11) -indicates Timed-out (a single test)
|
|
12: singleTestingFailure(12) -indicates A single test fails
|
|
13: outtime(13) -indicates Timed-out (test)
|
|
14: dslReportFailure(14) -indicates DSL report fails;
|
|
15: notTesting(15) -indicates Not tested
|
|
16: testingAbnormal(16) -indicates Test abnormal
|
|
"
|
|
::= { hwIsdnUserDiagnoseTestOprEntry 2 }
|
|
|
|
hwPstnSignalToneTestOprTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF HwPstnSignalToneTestOprEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Operation table for the PSTN signal tone test:
|
|
It realizes the function of the PSTN signal tone test in the system. This test helps check whether the dial tone and the dial tone delay function.
|
|
The index of this table is ifIndex"
|
|
::= { hwNTestMIBObjects 14 }
|
|
|
|
hwPstnSignalToneTestOprEntry OBJECT-TYPE
|
|
SYNTAX HwPstnSignalToneTestOprEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Operation table for the PSTN signal tone test:
|
|
It realizes the function of the PSTN signal tone test in the system. This test helps check whether the dial tone and the dial tone delay function.
|
|
The index of this entry is ifIndex"
|
|
INDEX {
|
|
ifIndex
|
|
}
|
|
::= { hwPstnSignalToneTestOprTable 1 }
|
|
|
|
HwPstnSignalToneTestOprEntry ::=
|
|
SEQUENCE
|
|
{
|
|
hwPstnSignalToneTestOprType INTEGER,
|
|
hwPstnSignalToneTestBusyFlag INTEGER,
|
|
hwPstnSignalToneTestResult INTEGER,
|
|
hwPstnSignalToneTestDTDelayTime Integer32,
|
|
hwPstnSignalTonePlayTime Integer32,
|
|
hwPstnSignalToneActualDeferTime Integer32,
|
|
hwPstnSignalToneTestMode INTEGER,
|
|
hwPstnSignalToneTestRequestID Integer32,
|
|
hwPstnSignalToneTestDTStop INTEGER
|
|
}
|
|
|
|
hwPstnSignalToneTestOprType OBJECT-TYPE
|
|
SYNTAX INTEGER{dialtone(1), dailtoneDelay(2), specialdailtone(3), stopTest(4), ringbacktone(5), busytone(6), invalidValue(-1) }
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Operation type.
|
|
Options:
|
|
1. dialtone(1) -indicates Dial tone test
|
|
2. dailtoneDelay(2) -indicates Dial tone delay test
|
|
3. specialdailtone(3) -indicates Special Dial tone test
|
|
4. stopTest(4) -indicates Stop Dial tone test
|
|
5. ringbacktone(5) -indicates Ring back tone test
|
|
6. busytone(6) -indicates Busy tone test
|
|
7. invalidValue(-1) -indicates Invalid value
|
|
"
|
|
::= { hwPstnSignalToneTestOprEntry 1 }
|
|
|
|
hwPstnSignalToneTestBusyFlag OBJECT-TYPE
|
|
SYNTAX INTEGER{busynotest(1), busystrentest(2), invalidvalue(-1) }
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Signal tone test-Busy control.
|
|
Options:
|
|
1. busynotest(1) -indicates no test when busy
|
|
2. busystrentest(2) -indicates forced test when busy
|
|
3. invalidvalue(-1) -indicates Invalid value
|
|
"
|
|
::= { hwPstnSignalToneTestOprEntry 2 }
|
|
|
|
hwPstnSignalToneTestResult OBJECT-TYPE
|
|
SYNTAX INTEGER{signaltoneNormal(1), noSignaltone(2), signaltoneAbnormal(3), unknownError(4),testingAbnormal(5),broadbandtesting(6),capturefail(7),notratb(8),notone(9),testnotfinish(10)}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Operation result.
|
|
Options:
|
|
1. signaltoneNormal(1) -indicates Signal tone normal
|
|
2. noSignaltone(2) -indicates No signal tone
|
|
3. signaltoneAbnormal(3) -indicates Signal tone abnormal
|
|
4. unknownError(4) -indicates Unknown error
|
|
5. testingAbnormal(5) -indicates Test abnormal
|
|
6. broadbandtesting(6) -indicates Broadband testing
|
|
7. capturefail(7) -indicates Line capture failure
|
|
8. notratb(8) -indicates Relay transfer board does not exist
|
|
9. notone(9) -indicates No tone
|
|
10. testnotfinish(10) -indicates signal tone test not finish
|
|
"
|
|
::= { hwPstnSignalToneTestOprEntry 3 }
|
|
|
|
hwPstnSignalToneTestDTDelayTime OBJECT-TYPE
|
|
SYNTAX Integer32(-1 | 0..65535)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Dial tone delay.
|
|
Unit: millisecond
|
|
"
|
|
::= { hwPstnSignalToneTestOprEntry 4 }
|
|
|
|
|
|
hwPstnSignalTonePlayTime OBJECT-TYPE
|
|
SYNTAX Integer32(-1 | 5..30)
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Tone play time.
|
|
Default: 10
|
|
Unit: second
|
|
"
|
|
|
|
::= { hwPstnSignalToneTestOprEntry 5 }
|
|
|
|
hwPstnSignalToneActualDeferTime OBJECT-TYPE
|
|
SYNTAX Integer32(-1 | 0..65535)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Signal Actually Defer Timer.
|
|
Unit: millisecond
|
|
"
|
|
|
|
::= { hwPstnSignalToneTestOprEntry 6 }
|
|
|
|
hwPstnSignalToneTestMode OBJECT-TYPE
|
|
SYNTAX INTEGER{outOfService(1), inService(2), invalidValue(-1)}
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Test Mode.
|
|
Options:
|
|
1. outOfService(1) -Test port not need in service
|
|
2. inService(2) -Test port must be in servcie
|
|
3. invalidValue(-1) -Invalid value
|
|
"
|
|
::= { hwPstnSignalToneTestOprEntry 7 }
|
|
|
|
hwPstnSignalToneTestRequestID OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
Request ID
|
|
"
|
|
::= { hwPstnSignalToneTestOprEntry 8 }
|
|
|
|
hwPstnSignalToneTestDTStop OBJECT-TYPE
|
|
SYNTAX INTEGER{yes(1), no(2), invalidValue(-1)}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
Detect stop dial tone.
|
|
Options:
|
|
1.yes(1) -Detected stop dial tone
|
|
2.no(2) -Not detected stop dial tone
|
|
3.invalidValue(-1) -Invalid value
|
|
"
|
|
::= { hwPstnSignalToneTestOprEntry 9 }
|
|
|
|
hwIsdnMeterTestOprTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF HwIsdnMeterTestOprEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Operation table for the ISDN meter test:
|
|
It realizes the function of the ISDN meter test in the system. The test board provides, through the meter test function, the interface connected to the external test meter such as the multimeter.
|
|
The index of this table is ifIndex"
|
|
::= { hwNTestMIBObjects 15 }
|
|
|
|
|
|
|
|
hwIsdnMeterTestOprEntry OBJECT-TYPE
|
|
SYNTAX HwIsdnMeterTestOprEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Operation table for the ISDN meter test:
|
|
It realizes the function of the ISDN meter test in the system. The test board provides, through the meter test function, the interface connected to the external test meter such as the multimeter.
|
|
The index of this entry is ifIndex"
|
|
INDEX {
|
|
ifIndex
|
|
}
|
|
::= { hwIsdnMeterTestOprTable 1 }
|
|
|
|
HwIsdnMeterTestOprEntry ::=
|
|
SEQUENCE {
|
|
hwIsdnMeterTestOprType
|
|
INTEGER,
|
|
hwIsdnMeterTestItem
|
|
INTEGER,
|
|
hwIsdnMeterTestStatus
|
|
INTEGER
|
|
}
|
|
|
|
hwIsdnMeterTestOprType OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
stop(1),
|
|
start(2)
|
|
}
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Describes the Operation type.
|
|
Options:
|
|
1. stop(1) -stop the test
|
|
2. start(2) -start the test
|
|
"
|
|
::= { hwIsdnMeterTestOprEntry 1 }
|
|
|
|
hwIsdnMeterTestItem OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
inline(1),
|
|
outline(2)
|
|
}
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Test item.
|
|
Options:
|
|
1. inline(1) -indicates Circuit test
|
|
2. outline(2) -indicates Loop-line test
|
|
"
|
|
::= { hwIsdnMeterTestOprEntry 2 }
|
|
|
|
hwIsdnMeterTestStatus OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
success(1),
|
|
fail(2),
|
|
portbusy(3),
|
|
outoftime(4),
|
|
testingAbnormal(5)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Test status.
|
|
Options:
|
|
1. success(1) -indicates normal
|
|
2. fail(2) -indicates abnormal
|
|
3. portbusy(3) -indicates busy port
|
|
4. outoftime(4) -indicates timed-out
|
|
5. testingAbnormal(5) -indicates test abnormal
|
|
"
|
|
::= { hwIsdnMeterTestOprEntry 3 }
|
|
|
|
hwTestBusTestOprTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF HwTestBusTestOprEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Test on the circuit/loop-line test bus:
|
|
It realizes the function of the test on the circuit/loop-line test bus. This test helps check whether the circuit/loop-line test bus is normal.
|
|
The index of this table is hwTestGroupNo"
|
|
::= { hwNTestMIBObjects 16 }
|
|
|
|
hwTestBusTestOprEntry OBJECT-TYPE
|
|
SYNTAX HwTestBusTestOprEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Test on the circuit/loop-line test bus:
|
|
It realizes the function of the test on the circuit/loop-line test bus. This test helps check whether the circuit/loop-line test bus is normal.
|
|
The index of this entry is hwTestGroupNo"
|
|
INDEX {
|
|
hwTestGroupNo
|
|
}
|
|
::= { hwTestBusTestOprTable 1 }
|
|
|
|
HwTestBusTestOprEntry ::=
|
|
SEQUENCE
|
|
{
|
|
hwTestBusTestOprType INTEGER,
|
|
hwTestBusTestBusType INTEGER,
|
|
hwTestBusTestResult INTEGER,
|
|
hwTestBusTestVoltage Integer32,
|
|
hwTestBusTestResistance Integer32,
|
|
hwTestBusTestCapacitance Integer32
|
|
}
|
|
|
|
hwTestBusTestOprType OBJECT-TYPE
|
|
SYNTAX INTEGER{stop(1), start(2) }
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Describes the Operation type.
|
|
Options:
|
|
1. stop(1) -stop the test
|
|
2. start(2) -start the test
|
|
"
|
|
::= { hwTestBusTestOprEntry 1 }
|
|
|
|
hwTestBusTestBusType OBJECT-TYPE
|
|
SYNTAX INTEGER{inbus(1), outbus(2) }
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Operation type.
|
|
Options:
|
|
1. inbus(1) -indicates Circuit test bus
|
|
2. outbus(2) -indicates Loop-line test bus
|
|
"
|
|
::= { hwTestBusTestOprEntry 2 }
|
|
|
|
hwTestBusTestResult OBJECT-TYPE
|
|
SYNTAX INTEGER{testbusNormal(1), voltageAbnormal(2), resistanceAbnormal(3),capacitanceAbnormal(4), testOutoftime(5),
|
|
unknownError(6),testingAbnormal(7),broadbandtesting(8),capturefail(9),notratb(10)}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Operation result.
|
|
Options:
|
|
1. testbusNormal(1) -indicates Normal
|
|
2. voltageAbnormal(2) -indicates Voltage abnormal
|
|
3. resistanceAbnormal(3) -indicates Resistance abnormal
|
|
4. capacitanceAbnormal(4) -indicates Capacitance abnormal
|
|
5. testOutoftime(5) -indicates Timed-out
|
|
6. unknownError(6) -indicates Unknown error
|
|
7. testingAbnormal(7) -indicates Test abnormal
|
|
8. broadbandtesting(8) -indicates Broadband testing
|
|
9. capturefail(9) -indicates Line capture failure
|
|
10. notratb(10) -indicates Relay transfer board does not exist
|
|
"
|
|
::= { hwTestBusTestOprEntry 3 }
|
|
|
|
hwTestBusTestVoltage OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Voltage.
|
|
Unit: millivolt, ab. mV
|
|
"
|
|
::= { hwTestBusTestOprEntry 4 }
|
|
|
|
hwTestBusTestResistance OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Resistance.
|
|
Unit: ohm
|
|
"
|
|
::= { hwTestBusTestOprEntry 5 }
|
|
|
|
hwTestBusTestCapacitance OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Capacitance.
|
|
Unit: nF
|
|
"
|
|
::= { hwTestBusTestOprEntry 6 }
|
|
|
|
hwFrameLooplineAdjustOprTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF HwFrameLooplineAdjustOprEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The loop line test for get check value.
|
|
The index of this table is hwFrameIndex"
|
|
::= { hwNTestMIBObjects 17 }
|
|
|
|
hwFrameLooplineAdjustOprEntry OBJECT-TYPE
|
|
SYNTAX HwFrameLooplineAdjustOprEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The loop line test for get check value.
|
|
The index of this entry is hwFrameIndex"
|
|
INDEX {
|
|
hwFrameIndex
|
|
}
|
|
::= { hwFrameLooplineAdjustOprTable 1 }
|
|
|
|
HwFrameLooplineAdjustOprEntry ::=
|
|
SEQUENCE
|
|
{
|
|
hwFrameLooplineAdjustCutlineSlotID Integer32,
|
|
hwFrameLooplineAdjustCutlinePortID Integer32,
|
|
hwFrameLooplineAdjustSelfMixedSlotID Integer32,
|
|
hwFrameLooplineAdjustSelfMixedPortID Integer32,
|
|
hwFrameLooplineAdjustOprType INTEGER,
|
|
hwFrameLooplineAdjustResult INTEGER,
|
|
hwFrameLooplineAdjustOprCab Integer32,
|
|
hwFrameLooplineAdjustOprCag Integer32,
|
|
hwFrameLooplineAdjustOprCbg Integer32,
|
|
hwFrameLooplineAdjustOprRab Integer32,
|
|
hwFrameLooplineAdjustFrameIndex Integer32,
|
|
hwFrameLooplineAdjustRequestID Integer32,
|
|
hwFrameLooplineAdjustBusyFlag INTEGER
|
|
}
|
|
|
|
hwFrameLooplineAdjustCutlineSlotID OBJECT-TYPE
|
|
SYNTAX Integer32(0..63)
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Slot ID.
|
|
Range:0-63
|
|
"
|
|
::= { hwFrameLooplineAdjustOprEntry 1 }
|
|
|
|
hwFrameLooplineAdjustCutlinePortID OBJECT-TYPE
|
|
SYNTAX Integer32(0..63)
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Port ID.
|
|
Range:0-63
|
|
"
|
|
::= { hwFrameLooplineAdjustOprEntry 2 }
|
|
|
|
hwFrameLooplineAdjustSelfMixedSlotID OBJECT-TYPE
|
|
SYNTAX Integer32(0..63)
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Slot ID.
|
|
Range:0-63
|
|
"
|
|
::= { hwFrameLooplineAdjustOprEntry 3 }
|
|
|
|
hwFrameLooplineAdjustSelfMixedPortID OBJECT-TYPE
|
|
SYNTAX Integer32(0..63)
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Port ID.
|
|
Range:0-63
|
|
"
|
|
::= { hwFrameLooplineAdjustOprEntry 4 }
|
|
|
|
|
|
hwFrameLooplineAdjustOprType OBJECT-TYPE
|
|
SYNTAX INTEGER{test(1), modify(2), restore(3)}
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Operation type.
|
|
Options:
|
|
1. test(1) -indicates test
|
|
2. modify(2) -indicates modify the test
|
|
3. restore(3) -indicates return to normal
|
|
"
|
|
::= { hwFrameLooplineAdjustOprEntry 5 }
|
|
|
|
hwFrameLooplineAdjustResult OBJECT-TYPE
|
|
SYNTAX INTEGER{normal(1), outoftime(2), unknownError(3),notgetselfmixedvalue(4),notgetcutlinevalue(5),notgetallvalue(6)}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Operation result.
|
|
Options:
|
|
1: normal(1) -indicates Normal
|
|
2: outoftime(2) -indicates Timed-out
|
|
3: unknownError(3) -indicates Unknown error
|
|
4: notgetselfmixedvalue(4) -indicates Failed to obtain the self-mixed calibration value
|
|
5: notgetcutlinevalue(5) -indicates Failed to obtain the cut-line calibration value
|
|
6: notgetallvalue(6) -indicates Failed to obtain the self-mixed and cut-line values
|
|
"
|
|
::= { hwFrameLooplineAdjustOprEntry 6 }
|
|
|
|
hwFrameLooplineAdjustOprCab OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A-B capacitance.
|
|
Unit: nF
|
|
"
|
|
::= { hwFrameLooplineAdjustOprEntry 7 }
|
|
|
|
hwFrameLooplineAdjustOprCag OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A-Ground capacitance.
|
|
Unit: nF
|
|
"
|
|
::= { hwFrameLooplineAdjustOprEntry 8 }
|
|
|
|
hwFrameLooplineAdjustOprCbg OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"B-Ground capacitance.
|
|
Unit: nF
|
|
"
|
|
::= { hwFrameLooplineAdjustOprEntry 9 }
|
|
|
|
|
|
hwFrameLooplineAdjustOprRab OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A-B resistance..
|
|
Unit: ohm
|
|
"
|
|
::= { hwFrameLooplineAdjustOprEntry 10 }
|
|
|
|
hwFrameLooplineAdjustFrameIndex OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Frame index"
|
|
::= { hwFrameLooplineAdjustOprEntry 11 }
|
|
|
|
hwFrameLooplineAdjustRequestID OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Request ID"
|
|
::= { hwFrameLooplineAdjustOprEntry 12 }
|
|
|
|
hwFrameLooplineAdjustBusyFlag OBJECT-TYPE
|
|
SYNTAX INTEGER{cancel(1), force(2), invalid(-1)}
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Whether test or not when port is busy.
|
|
Options:
|
|
1: cancel(1) -indicates notest
|
|
2: force(2) -indicates test
|
|
3: invalid(-1) -indicates invalid
|
|
"
|
|
::= { hwFrameLooplineAdjustOprEntry 13 }
|
|
|
|
hwFrameLooplineAdjustTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF HwFrameLooplineAdjustEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"GET table for the shelf calibration values:
|
|
It realizes the function of obtaining the shelf calibration values.
|
|
The index of this table is hwFrameIndex."
|
|
::= { hwNTestMIBObjects 18 }
|
|
|
|
hwFrameLooplineAdjustEntry OBJECT-TYPE
|
|
SYNTAX HwFrameLooplineAdjustEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"GET table for the shelf calibration values:
|
|
It realizes the function of obtaining the shelf calibration values.
|
|
The index of this entry is hwFrameIndex."
|
|
INDEX {
|
|
hwFrameIndex
|
|
}
|
|
::= { hwFrameLooplineAdjustTable 1 }
|
|
|
|
HwFrameLooplineAdjustEntry ::=
|
|
SEQUENCE
|
|
{
|
|
hwFrameLooplineAdjustFlag INTEGER,
|
|
hwFrameLooplineAdjustCab Integer32,
|
|
hwFrameLooplineAdjustCag Integer32,
|
|
hwFrameLooplineAdjustCbg Integer32,
|
|
hwFrameLooplineAdjustRab Integer32
|
|
}
|
|
|
|
hwFrameLooplineAdjustFlag OBJECT-TYPE
|
|
SYNTAX INTEGER{nosetflag(1), capacitanceflag(2), resistanceflag(3), allsetflag(4)}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Calibration value flag of the loop-line test.
|
|
Options:
|
|
1: nosetflag(1) -indicates No calibration value is set
|
|
2: capacitanceflag(2) -indicates The capacitance calibration value is set
|
|
3: resistanceflag(3) -indicates The resistance calibration value is set
|
|
4: allsetflag(4) -indicates All the calibration values are set
|
|
"
|
|
::= { hwFrameLooplineAdjustEntry 1 }
|
|
|
|
hwFrameLooplineAdjustCab OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A-B capacitance"
|
|
::= { hwFrameLooplineAdjustEntry 2 }
|
|
|
|
hwFrameLooplineAdjustCag OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A-Ground capacitance"
|
|
::= { hwFrameLooplineAdjustEntry 3 }
|
|
|
|
|
|
hwFrameLooplineAdjustCbg OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"B-Ground capacitance"
|
|
::= { hwFrameLooplineAdjustEntry 4 }
|
|
|
|
|
|
hwFrameLooplineAdjustRab OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A-B resistance"
|
|
::= { hwFrameLooplineAdjustEntry 5 }
|
|
|
|
hwQosTestIndexNext OBJECT-TYPE
|
|
SYNTAX Integer32 (0..16)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object contains an appropriate value to
|
|
be used for hwQosTestIndex when creating
|
|
entries in the hwQosTestTable. The value
|
|
0 indicates that no unassigned entries are
|
|
available. To obtain the hwQosTestIndex
|
|
value for a new entry, the manager issues a
|
|
management protocol retrieval operation to obtain
|
|
the current value of this object. After each
|
|
retrieval, the agent should modify the value to
|
|
the next unassigned index.
|
|
After a manager retrieves a value the agent will
|
|
determine through its local policy when this index
|
|
value will be made available for reuse."
|
|
::= { hwNTestMIBObjects 19 }
|
|
|
|
hwQosTestOprTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF HwQosTestOprEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Table for the QoS test.
|
|
The index of this table is hwQosTestIndex."
|
|
::= { hwNTestMIBObjects 20 }
|
|
|
|
hwQosTestOprEntry OBJECT-TYPE
|
|
SYNTAX HwQosTestOprEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Table for the QoS test.
|
|
The index of this entry is hwQosTestIndex."
|
|
INDEX {
|
|
hwQosTestIndex
|
|
}
|
|
::= { hwQosTestOprTable 1 }
|
|
|
|
HwQosTestOprEntry ::=
|
|
SEQUENCE
|
|
{
|
|
hwQosTestIndex Integer32,
|
|
hwQosTestGWAddr IpAddress,
|
|
hwQosTestPeerAddr IpAddress,
|
|
hwQosTestDuration Integer32,
|
|
hwQosTestTick Integer32,
|
|
hwQosTestRowStatus RowStatus,
|
|
hwQosTestInPkts Integer32,
|
|
hwQosTestOutPkts Integer32,
|
|
hwQosTestInOctets Integer32,
|
|
hwQosTestOutOctets Integer32,
|
|
hwQosTestInDropPkts Integer32,
|
|
hwQosTestStatsMaxDropPktsRate Integer32,
|
|
hwQosTestStatsMaxDropPktsPort OCTET STRING,
|
|
hwQosTestStatsMinDropPktsRate Integer32,
|
|
hwQosTestStatsMinDropPktsPort OCTET STRING,
|
|
hwQosTestStatsMaxDitherDelay Integer32,
|
|
hwQosTestStatsMaxDitherPort OCTET STRING,
|
|
hwQosTestStatsMinDitherDelay Integer32,
|
|
hwQosTestStatsMinDitherPort OCTET STRING,
|
|
hwQosTestStatsMaxLoopDelay Integer32,
|
|
hwQosTestStatsMaxLoopPort OCTET STRING,
|
|
hwQosTestStatsMinLoopDelay Integer32,
|
|
hwQosTestStatsMinLoopPort OCTET STRING
|
|
}
|
|
|
|
hwQosTestIndex OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Index of the a test"
|
|
::={ hwQosTestOprEntry 1 }
|
|
|
|
hwQosTestGWAddr OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"IP address of the local gateway"
|
|
::={ hwQosTestOprEntry 2 }
|
|
|
|
hwQosTestPeerAddr OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"IP address of the peer gateway (or NAT, SAN)"
|
|
::={ hwQosTestOprEntry 3 }
|
|
|
|
hwQosTestDuration OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Test duration. By default, the test duration is one hour.
|
|
Default:3600"
|
|
DEFVAL { 3600 }
|
|
::={ hwQosTestOprEntry 4 }
|
|
|
|
hwQosTestTick OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Report cycle. By default, the report cycle is 60s.
|
|
Default:60"
|
|
DEFVAL { 60 }
|
|
::={ hwQosTestOprEntry 5 }
|
|
|
|
hwQosTestRowStatus OBJECT-TYPE
|
|
SYNTAX RowStatus
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Row status"
|
|
::={ hwQosTestOprEntry 6 }
|
|
|
|
hwQosTestInPkts OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Test In Pkts"
|
|
::={ hwQosTestOprEntry 7 }
|
|
|
|
hwQosTestOutPkts OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Test Out Pkts"
|
|
::={ hwQosTestOprEntry 8 }
|
|
|
|
hwQosTestInOctets OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Test In Octets"
|
|
::={ hwQosTestOprEntry 9 }
|
|
|
|
hwQosTestOutOctets OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Test Out Octets"
|
|
::={ hwQosTestOprEntry 10 }
|
|
|
|
hwQosTestInDropPkts OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Test In Drop Pkts"
|
|
::={ hwQosTestOprEntry 11 }
|
|
|
|
hwQosTestStatsMaxDropPktsRate OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Test Stats Max Drop Pkts Rate"
|
|
::={ hwQosTestOprEntry 12 }
|
|
|
|
hwQosTestStatsMaxDropPktsPort OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Test Stats Max Drop Pkts Port"
|
|
::={ hwQosTestOprEntry 13 }
|
|
|
|
hwQosTestStatsMinDropPktsRate OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Test Stats Min Drop Pkts Rate"
|
|
::={ hwQosTestOprEntry 14 }
|
|
|
|
hwQosTestStatsMinDropPktsPort OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Test Stats Min Drop Pkts Port"
|
|
::={ hwQosTestOprEntry 15 }
|
|
|
|
hwQosTestStatsMaxDitherDelay OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Test Stats Max Dither Delay"
|
|
::={ hwQosTestOprEntry 16 }
|
|
|
|
hwQosTestStatsMaxDitherPort OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Test Stats Max Dither Port"
|
|
::={ hwQosTestOprEntry 17 }
|
|
|
|
hwQosTestStatsMinDitherDelay OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Test Stats Min Dither Delay"
|
|
::={ hwQosTestOprEntry 18 }
|
|
|
|
hwQosTestStatsMinDitherPort OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Test Stats Min Dither Port"
|
|
::={ hwQosTestOprEntry 19 }
|
|
|
|
hwQosTestStatsMaxLoopDelay OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Test Stats Max Loop Delay"
|
|
::={ hwQosTestOprEntry 20 }
|
|
|
|
hwQosTestStatsMaxLoopPort OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Test Stats Max Loop Port"
|
|
::={ hwQosTestOprEntry 21 }
|
|
|
|
hwQosTestStatsMinLoopDelay OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Test Stats Min Loop Delay"
|
|
::={ hwQosTestOprEntry 22 }
|
|
|
|
hwQosTestStatsMinLoopPort OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Test Stats Min Loop Port"
|
|
::={ hwQosTestOprEntry 23 }
|
|
|
|
|
|
|
|
|
|
hwPotsLooplineThresholdTable OBJECT IDENTIFIER ::= { hwNTestMIBObjects 21 }
|
|
|
|
-- Associated command lines
|
|
-- Name of the threshold for the line test Threshold
|
|
-- Hazardous AC voltage level (V) 50
|
|
-- Foreign EMF DC voltage level (V) 10
|
|
-- Loop line grounding Ground resistance threshold (ohm) 20000
|
|
-- Off hook: A-B resistance lower limit (ohm) 3000
|
|
-- Off hook: A-B resistance upper limit (ohm) 100000
|
|
-- Off hook: Loop resistance lower limit (ohm) 100
|
|
-- Off hook: Loop resistance upper limit (ohm) 3000
|
|
-- Loop-line mixed with others: A-B resistance threshold (ohm) 2000
|
|
-- A-B insulation difference: A-B resistance lower limit (ohm) 2000
|
|
-- A-B insulation difference: A-B resistance upper limit (ohm). 20000
|
|
-- Leakage: Ground capacitance threshold (nF) 700
|
|
-- Normal: Ground capacitance threshold 1 (nF) 200
|
|
-- Normal: Ground capacitance threshold 2 (nF) 350
|
|
-- Normal: Ground capacitance threshold 3 (nF) 50
|
|
-- A-B Impedance Abnormal: A-B impedance min. threshold(ohm) 10000
|
|
-- AC current Abnormal: AC current threshold(amp) 1000
|
|
-- DC current Abnormal: DC current threshold(amp) 1000
|
|
-- AC Voltage Abnormal: AC voltage threshold(volt) 10
|
|
-- DC Voltage Abnormal: DC voltage threshold 1(volt) 10
|
|
-- DC Voltage Abnormal: DC voltage threshold 2(volt) -55
|
|
-- On hook Loop-Electric Current Abnormal: on hook loop-Electric Current max. threshold(amp) 30
|
|
-- On hook Loop Resistance Abnormal: on hook Loop Resistance threshold(ohm) 250000
|
|
-- Off hook Loop Resistance Abnormal: off hook Loop Resistance threshold(ohm) 250000
|
|
-- Ground Insulation Resistance Abnormal: ground insulation Resistance threshold 1(ohm) 5000000
|
|
-- Ground Insulation Resistance Abnormal: ground insulation Resistance threshold 2(ohm) 2500000
|
|
-- Ground Capacitance Abnormal: ground capacitance threshold 1(nF) 200
|
|
-- A-B Capacitance Abnormal: A-B capacitance min. threshold(nF) 100
|
|
-- A-B Capacitance Abnormal: A-B capacitance max. threshold(nF) 600
|
|
-- Noise Abnormal: Noise threshold(dBm) 65
|
|
-- Cable characteristic capacitance per unit length between tip and ring (nf per km) 19
|
|
-- Cable characteristic capacitance per unit length between tip and GND and ring and GND (nf per km) 62
|
|
-- Cable loop DC resistance per unit length (sum of both wires).(ohm per km) 295
|
|
-- maximum resistance for tip or ring short-circuit to GND (ohm) 2000
|
|
-- maximum resistance for tip or ring leakage to GND (ohm) 200000
|
|
-- Hazardous DC voltage level (mV) 80000
|
|
-- Foreign EMF AC voltage level (mVrms) 10000
|
|
-- minimum ETSI signature capacitance (nf) 350
|
|
-- maximum ETSI signature capacitance(nf) 520
|
|
-- minimum PPA resisitance(ohm) 350000
|
|
-- maximum PPA resistance(ohm) 520000
|
|
-- minimum voltage to conduct current through the zener diode(mV) 1000
|
|
-- maximum RC network resistance between tip and ring(ohm) 1000000
|
|
-- minimum RC network resistance between tip and ring (ohm) 10000
|
|
-- minimum RC network capacitance between tip and ring(nf) 350
|
|
-- minimum high resistance between tip and ring(ohm) 1000000
|
|
-- minimum foreign voltage(mV) 8000
|
|
-- minimum equivalent resistance when off-hook on zero kilometres(ohm) 200
|
|
-- line length windage for open wire failure(m) 200
|
|
--threshold operation type
|
|
|
|
hwTouchThePowerVolThreshold OBJECT-TYPE
|
|
SYNTAX Integer32(0..2147483647)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
Hazardous AC voltage level
|
|
Unit: V
|
|
Default: 50
|
|
"
|
|
::= { hwPotsLooplineThresholdTable 1 }
|
|
|
|
hwLoopLineMixedVolThreshold OBJECT-TYPE
|
|
SYNTAX Integer32(0..2147483647)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
Foreign EMF DC voltage level.
|
|
Unit: V
|
|
Default: 10
|
|
"
|
|
::= { hwPotsLooplineThresholdTable 2 }
|
|
|
|
hwLoopLineGroundingVolThreshold OBJECT-TYPE
|
|
SYNTAX Integer32(0..2147483647)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
Loop line grounding: Ground resistance threshold.
|
|
Unit: ohm
|
|
Default: 20000
|
|
"
|
|
::= { hwPotsLooplineThresholdTable 3 }
|
|
|
|
hwOffHookABMinThreshold OBJECT-TYPE
|
|
SYNTAX Integer32(0..2147483647)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
Off-hook: A-B resistance lower limit.
|
|
Unit: ohm
|
|
Default: 3000
|
|
"
|
|
::= { hwPotsLooplineThresholdTable 4 }
|
|
|
|
hwOffHookABMaxThreshold OBJECT-TYPE
|
|
SYNTAX Integer32(0..2147483647)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
Off-hook: A-B resistance upper limit.
|
|
Unit: ohm
|
|
Default: 100000
|
|
"
|
|
::= { hwPotsLooplineThresholdTable 5 }
|
|
|
|
hwOffHookLoopMinThreshold OBJECT-TYPE
|
|
SYNTAX Integer32(0..2147483647)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
Off-hook: loop resistance lower limit.
|
|
Unit: ohm
|
|
Initial value: 100
|
|
"
|
|
::= { hwPotsLooplineThresholdTable 6 }
|
|
|
|
hwOffHookLoopMaxThreshold OBJECT-TYPE
|
|
SYNTAX Integer32(0..2147483647)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
Off-hook: loop resistance upper limit.
|
|
Unit: ohm
|
|
Initial value: 3000
|
|
"
|
|
::= { hwPotsLooplineThresholdTable 7 }
|
|
|
|
hwLoopLineMixedABThreshold OBJECT-TYPE
|
|
SYNTAX Integer32(0..2147483647)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
Loop line mixed with others: A-B resistance threshold.
|
|
Unit: ohm
|
|
Initial value: 2000
|
|
"
|
|
::= { hwPotsLooplineThresholdTable 8 }
|
|
|
|
hwABPoorLineInsulationMinThreshold OBJECT-TYPE
|
|
SYNTAX Integer32(0..2147483647)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
A-B insulation difference: A-B resistance lower limit.
|
|
Unit: ohm
|
|
Initial value: 2000
|
|
"
|
|
::= { hwPotsLooplineThresholdTable 9 }
|
|
|
|
hwABPoorLineInsulationMaxThreshold OBJECT-TYPE
|
|
SYNTAX Integer32(0..2147483647)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
A-B insulation difference: A-B resistance upper limit.
|
|
Unit: ohm
|
|
Default: 20000
|
|
"
|
|
::= { hwPotsLooplineThresholdTable 10 }
|
|
|
|
hwLeakageGroundCapThreshold OBJECT-TYPE
|
|
SYNTAX Integer32(0..2147483647)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
Leakage: ground capacitance threshold.
|
|
Unit: nF
|
|
Default: 700
|
|
"
|
|
::= { hwPotsLooplineThresholdTable 11 }
|
|
|
|
hwNormalGroundCap1Threshold OBJECT-TYPE
|
|
SYNTAX Integer32(0..2147483647)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
Normal: ground capacitance threshold 1.
|
|
Unit: nF
|
|
Default: 200
|
|
"
|
|
::= { hwPotsLooplineThresholdTable 12 }
|
|
|
|
hwNormalGroundCap2Threshold OBJECT-TYPE
|
|
SYNTAX Integer32(0..2147483647)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
Normal: ground capacitance threshold 2.
|
|
Unit: nF
|
|
Default: 350
|
|
"
|
|
::= { hwPotsLooplineThresholdTable 13 }
|
|
|
|
hwNormalGroundCap3Threshold OBJECT-TYPE
|
|
SYNTAX Integer32(0..2147483647)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
Normal: ground capacitance threshold 3.
|
|
Unit: nF
|
|
Default: 50
|
|
"
|
|
::= { hwPotsLooplineThresholdTable 14 }
|
|
|
|
hwAbnormalImpedanceABhreshold OBJECT-TYPE
|
|
SYNTAX Integer32(0..2147483647)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
On hook: lower limit of the A-B abnormal impedance (ohm)
|
|
Default: 10000
|
|
"
|
|
::= { hwPotsLooplineThresholdTable 15 }
|
|
|
|
hwAbnormalACElectricCurrentThreshold OBJECT-TYPE
|
|
SYNTAX Integer32(0..2147483647)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
Abnormal AC current: threshold of the abnormal AC current (mA)
|
|
Default: 1000
|
|
"
|
|
::= { hwPotsLooplineThresholdTable 16 }
|
|
|
|
hwAbnormalDCElectricCurrentThreshold OBJECT-TYPE
|
|
SYNTAX Integer32(0..2147483647)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
Abnormal DC current: threshold of the abnormal DC current (mA)
|
|
Default: 1000
|
|
"
|
|
::= { hwPotsLooplineThresholdTable 17 }
|
|
|
|
hwAbnormalACVoltageThreshold OBJECT-TYPE
|
|
SYNTAX Integer32(0..2147483647)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
Abnormal AC voltage: threshold 1 of the abnormal AC voltage (V)
|
|
Default: 10
|
|
"
|
|
::= { hwPotsLooplineThresholdTable 18 }
|
|
|
|
hwAbnormalDCVoltage1Threshold OBJECT-TYPE
|
|
SYNTAX Integer32(0..2147483647)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
Abnormal DC voltage: threshold 1 of the abnormal DC voltage (V)
|
|
Default: 10
|
|
"
|
|
::= { hwPotsLooplineThresholdTable 19 }
|
|
|
|
hwAbnormalDCVoltage2Threshold OBJECT-TYPE
|
|
SYNTAX Integer32(0..2147483647)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
Abnormal DC voltage: threshold 2 of the abnormal DC voltage (V)
|
|
Default: 55
|
|
"
|
|
::= { hwPotsLooplineThresholdTable 20 }
|
|
|
|
hwAbnormalOnhookLoopLineElectricCurrentMaxThreshold OBJECT-TYPE
|
|
SYNTAX Integer32(0..2147483647)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
Abnormal on-hook loop current: upper limit of the abnormal on-hook loop current (mA)
|
|
Default: 30
|
|
"
|
|
::= { hwPotsLooplineThresholdTable 21 }
|
|
|
|
hwAbnormalOnhookLoopResistanceThreshold OBJECT-TYPE
|
|
SYNTAX Integer32(0..2147483647)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
Abnormal on-hook loop resistance: threshold of the abnormal on-hook loop resistance (ohm)
|
|
Default: 250000
|
|
"
|
|
::= { hwPotsLooplineThresholdTable 22 }
|
|
|
|
hwAbnormalOffhookLoopResistanceThreshold OBJECT-TYPE
|
|
SYNTAX Integer32(0..2147483647)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
Abnormal off-hook loop resistance: threshold of the abnormal off-hook loop resistance (ohm)
|
|
Default: 250000
|
|
"
|
|
::= { hwPotsLooplineThresholdTable 23 }
|
|
|
|
hwAbnormalGroundInsulationResistance1Threshold OBJECT-TYPE
|
|
SYNTAX Integer32(0..2147483647)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
Abnormal ground insulation resistance: threshold 1 of the abnormal ground insulation resistance (ohm)
|
|
Default: 5000000
|
|
"
|
|
::= { hwPotsLooplineThresholdTable 24 }
|
|
|
|
hwAbnormalGroundPoorLineInsulation1Threshold OBJECT-TYPE
|
|
SYNTAX Integer32(0..2147483647)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
Abnormal ground insulation difference: threshold 1 of the abnormal ground insulation difference (ohm)
|
|
Default: 250000
|
|
"
|
|
::= { hwPotsLooplineThresholdTable 25 }
|
|
|
|
hwAbnormalGroundCapacitanceThreshold OBJECT-TYPE
|
|
SYNTAX Integer32(0..2147483647)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
Abnormal ground capacitance: threshold of the abnormal ground capacitance (nF)
|
|
Default: 200
|
|
"
|
|
::= { hwPotsLooplineThresholdTable 26 }
|
|
|
|
hwAbnormalCapacitanceABMinThreshold OBJECT-TYPE
|
|
SYNTAX Integer32(0..2147483647)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
Abnormal: lower limit of the abnormal A-B capacitance (nF)
|
|
Default: 0
|
|
"
|
|
::= { hwPotsLooplineThresholdTable 27 }
|
|
|
|
hwAbnormalCapacitanceABMaxThreshold OBJECT-TYPE
|
|
SYNTAX Integer32(0..2147483647)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
Abnormal: upper limit of the abnormal A-B capacitance (nF)
|
|
Default: 2000
|
|
"
|
|
::= { hwPotsLooplineThresholdTable 28 }
|
|
|
|
hwAbnormalNoiseThreshold OBJECT-TYPE
|
|
SYNTAX Integer32(0..2147483647)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
Abnormal noise: threshold 1 of the abnormal noise (dBm)
|
|
Default: 65
|
|
"
|
|
::= { hwPotsLooplineThresholdTable 29 }
|
|
|
|
hwLoopParamsCab OBJECT-TYPE
|
|
SYNTAX Integer32(0..2147483647)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
Cable characteristic capacitance per unit length between tip and ring
|
|
Unit : nf per km
|
|
Range: 0-100
|
|
Default: 19
|
|
"
|
|
::= { hwPotsLooplineThresholdTable 30 }
|
|
|
|
hwLoopParamsCagbg OBJECT-TYPE
|
|
SYNTAX Integer32(0..2147483647)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
Cable characteristic capacitance per unit length between tip and GND and ring and GND
|
|
Unit : nf per km
|
|
Range: 0-100
|
|
Default: 62
|
|
"
|
|
::= { hwPotsLooplineThresholdTable 31 }
|
|
|
|
hwLoopParamsRab OBJECT-TYPE
|
|
SYNTAX Integer32(0..2147483647)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
Cable loop DC resistance per unit length (sum of both wires)
|
|
Unit : ohm per km
|
|
Range: 50-600
|
|
Default: 295
|
|
"
|
|
::= { hwPotsLooplineThresholdTable 32 }
|
|
|
|
hwLrcThMaxsc OBJECT-TYPE
|
|
SYNTAX Integer32(0..2147483647)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
maximum resistance for tip or ring short-circuit to GND
|
|
Unit : ohm
|
|
Range: 0-1000000
|
|
Default: 2000
|
|
"
|
|
::= { hwPotsLooplineThresholdTable 33 }
|
|
|
|
hwLrcThMaxLg OBJECT-TYPE
|
|
SYNTAX Integer32(0..2147483647)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
maximum resistance for tip or ring leakage to GND
|
|
Unit : ohm
|
|
Range: 0-1000000
|
|
Default: 200000
|
|
"
|
|
::= { hwPotsLooplineThresholdTable 34}
|
|
|
|
hwHdcvL OBJECT-TYPE
|
|
SYNTAX Integer32(0..2147483647)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
Hazardous DC voltage level
|
|
Unit : mV
|
|
Range: 0-500000
|
|
Default: 80000
|
|
"
|
|
::= { hwPotsLooplineThresholdTable 35 }
|
|
|
|
hwFacvL OBJECT-TYPE
|
|
SYNTAX Integer32(0..2147483647)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
Foreign EMF AC voltage level
|
|
Unit : mVrms
|
|
Range: 0-200000
|
|
Default: 10000
|
|
"
|
|
::= { hwPotsLooplineThresholdTable 36 }
|
|
|
|
hwMinetsiSc OBJECT-TYPE
|
|
SYNTAX Integer32(0..2147483647)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
minimum ETSI signature capacitance
|
|
Unit : nf
|
|
Range: 100-500
|
|
Default: 350
|
|
"
|
|
::= { hwPotsLooplineThresholdTable 37}
|
|
|
|
hwMaxetsiSc OBJECT-TYPE
|
|
SYNTAX Integer32(0..2147483647)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
maximum ETSI signature capacitance
|
|
Unit : nf
|
|
Range: 500-1000
|
|
Default: 520
|
|
"
|
|
::= { hwPotsLooplineThresholdTable 38 }
|
|
|
|
hwMinetsiPr OBJECT-TYPE
|
|
SYNTAX Integer32(0..2147483647)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
minimum PPA resisitance
|
|
Unit : ohm
|
|
Range: 200000-400000
|
|
Default: 350000
|
|
"
|
|
::= { hwPotsLooplineThresholdTable 39 }
|
|
|
|
hwMaxetsiPr OBJECT-TYPE
|
|
SYNTAX Integer32(0..2147483647)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
maximum PPA resistance
|
|
Unit : ohm
|
|
Range: 400000-700000
|
|
Default: 520000
|
|
"
|
|
::= { hwPotsLooplineThresholdTable 40 }
|
|
|
|
hwMinZenerZv OBJECT-TYPE
|
|
SYNTAX Integer32(0..2147483647)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
minimum voltage to conduct current through the zener diode
|
|
Unit : mV
|
|
Range: 500-10000
|
|
Default: 1000
|
|
Step: 100
|
|
"
|
|
::= { hwPotsLooplineThresholdTable 41 }
|
|
|
|
hwMaxRcrTr OBJECT-TYPE
|
|
SYNTAX Integer32(0..2147483647)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
maximum RC network resistance between tip and ring
|
|
Unit : ohm
|
|
Range: 0-10000000
|
|
Default: 1000000
|
|
"
|
|
::= { hwPotsLooplineThresholdTable 42 }
|
|
|
|
hwMinRcrTr OBJECT-TYPE
|
|
SYNTAX Integer32(0..2147483647)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
minimum RC network resistance between tip and ring
|
|
Unit : ohm
|
|
Range: 0-10000000
|
|
Default: 10000
|
|
"
|
|
::= { hwPotsLooplineThresholdTable 43 }
|
|
|
|
hwCpeCab OBJECT-TYPE
|
|
SYNTAX Integer32(0..2147483647)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
minimum RC network capacitance between tip and ring
|
|
Unit : nf
|
|
Range: 0-5000
|
|
Default: 350
|
|
"
|
|
::= { hwPotsLooplineThresholdTable 44 }
|
|
|
|
hwMinhrTr OBJECT-TYPE
|
|
SYNTAX Integer32(0..2147483647)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
minimum high resistance between tip and ring
|
|
Unit : ohm
|
|
Range: 0-10000000
|
|
Default: 1000000
|
|
"
|
|
::= { hwPotsLooplineThresholdTable 45 }
|
|
|
|
|
|
hwFvcLim OBJECT-TYPE
|
|
SYNTAX Integer32(0..2147483647)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
minimum foreign voltage
|
|
Unit : mV
|
|
Range: 0-50000
|
|
Default: 8000
|
|
"
|
|
::= { hwPotsLooplineThresholdTable 46 }
|
|
|
|
hwMinOffhookR OBJECT-TYPE
|
|
SYNTAX Integer32(0..2147483647)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
minimum equivalent resistance when off-hook on zero kilometres
|
|
Unit : ohm
|
|
Range: 0-1000
|
|
Default: 200
|
|
"
|
|
::= { hwPotsLooplineThresholdTable 47 }
|
|
|
|
|
|
hwLepPar OBJECT-TYPE
|
|
SYNTAX Integer32(0..2147483647)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
line length windage for open wire failure
|
|
Unit : m
|
|
Range: 0-500
|
|
Default: 200
|
|
"
|
|
::= { hwPotsLooplineThresholdTable 48 }
|
|
|
|
hwLooplineThresholdOprType OBJECT-TYPE
|
|
SYNTAX INTEGER{restore(1), invalid(-1)}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Operation type.
|
|
Options:
|
|
1. restore(1) -restore default threshold value
|
|
2. invalid(-1) -invalid
|
|
"
|
|
::= { hwPotsLooplineThresholdTable 49 }
|
|
|
|
|
|
|
|
|
|
|
|
hwResistEmendationThresholdTable OBJECT IDENTIFIER ::= { hwNTestMIBObjects 22 }
|
|
|
|
-- Associated command lines
|
|
-- Name of the resistance calibration threshold for the line test Threshold
|
|
-- A-Ground resistance calibration value (ohm) 0
|
|
-- B-Ground resistance calibration value (ohm) 0
|
|
-- A-B resistance calibration value (ohm) 0
|
|
-- Loop resistance calibration value (ohm) 0
|
|
-- Polarity reversal resistance calibration value (ohm) 0
|
|
|
|
hwAGroundResistanceEmendation OBJECT-TYPE
|
|
SYNTAX Integer32(0..2147483647)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
A-Ground resistance calibration value .
|
|
Unit: ohm
|
|
Default: 0
|
|
"
|
|
::= { hwResistEmendationThresholdTable 1 }
|
|
|
|
hwBGroundResistanceEmendation OBJECT-TYPE
|
|
SYNTAX Integer32(0..2147483647)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
B-Ground resistance calibration value.
|
|
Unit: ohm
|
|
Default: 0
|
|
"
|
|
::= { hwResistEmendationThresholdTable 2 }
|
|
|
|
hwABResistanceEmendation OBJECT-TYPE
|
|
SYNTAX Integer32(0..2147483647)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
A-B resistance calibration value.
|
|
Unit: ohm
|
|
Default: 0
|
|
"
|
|
::= { hwResistEmendationThresholdTable 3 }
|
|
|
|
hwLoopResistanceEmendation OBJECT-TYPE
|
|
SYNTAX Integer32(0..2147483647)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
Loop resistance calibration value.
|
|
Unit: ohm
|
|
Default: 0
|
|
"
|
|
::= { hwResistEmendationThresholdTable 4 }
|
|
|
|
hwPolarityReversalResistanceEmendation OBJECT-TYPE
|
|
SYNTAX Integer32(0..2147483647)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
Polarity reversal resistance calibration value.
|
|
Unit: ohm
|
|
Default: 0
|
|
"
|
|
::= { hwResistEmendationThresholdTable 5 }
|
|
|
|
hwTestTimeLimitThresholdTable OBJECT IDENTIFIER ::= { hwNTestMIBObjects 23 }
|
|
|
|
--Associated command lines show the "test-time-limit"
|
|
|
|
-- Name of the threshold of the timeout control parameter for the line test Threshold
|
|
|
|
-- Timeout control parameter of the telephone test (minute) 15
|
|
-- Timeout control parameter of the call emulation test (minute) 15
|
|
-- Timeout control parameter of the digital subscriber diagnosis test 15
|
|
|
|
hwTelephoneTestWaitingAck OBJECT-TYPE
|
|
SYNTAX Integer32(1..60)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
Timeout control parameter of the telephone test.
|
|
Unit: minute
|
|
Default: 15
|
|
"
|
|
::= { hwTestTimeLimitThresholdTable 1 }
|
|
|
|
hwRemoteTestWaitingAck OBJECT-TYPE
|
|
SYNTAX Integer32(1..60)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
Timeout control parameter of the call emulation test.
|
|
Unit: minute
|
|
Default: 15
|
|
"
|
|
::= { hwTestTimeLimitThresholdTable 2 }
|
|
|
|
hwIsdnDiagnoseTestWaitingAck OBJECT-TYPE
|
|
SYNTAX Integer32(1..60)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
Timeout control parameter of the digital subscriber diagnosis test.
|
|
Unit: minute
|
|
Default: 15
|
|
"
|
|
::= { hwTestTimeLimitThresholdTable 3 }
|
|
|
|
hwSDLMeterTestOprTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF HwSDLMeterTestOprEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Operation table for the SDL meter test:
|
|
It realizes the function of the SDL meter test in the system. The test board provides, through the meter test function, the interface connected to the external test meter such as the multimeter.
|
|
The index of this table is ifIndex."
|
|
::= { hwNTestMIBObjects 24 }
|
|
|
|
|
|
|
|
hwSDLMeterTestOprEntry OBJECT-TYPE
|
|
SYNTAX HwSDLMeterTestOprEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Operation table for the SDL meter test:
|
|
It realizes the function of the SDL meter test in the system. The test board provides, through the meter test function, the interface connected to the external test meter such as the multimeter.
|
|
The index of this entry is ifIndex."
|
|
INDEX {
|
|
ifIndex
|
|
}
|
|
::= { hwSDLMeterTestOprTable 1 }
|
|
|
|
HwSDLMeterTestOprEntry ::=
|
|
SEQUENCE {
|
|
hwSDLMeterTestOprType
|
|
INTEGER,
|
|
hwSDLMeterTestStatus
|
|
INTEGER
|
|
}
|
|
|
|
hwSDLMeterTestOprType OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
stop(1),
|
|
start(2)
|
|
}
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Operation type.
|
|
Options:
|
|
1. stop(1) -stop the test
|
|
2. start(2) -start the test"
|
|
::= { hwSDLMeterTestOprEntry 1 }
|
|
|
|
hwSDLMeterTestStatus OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
success(1),
|
|
fail(2),
|
|
portbusy(3),
|
|
outoftime(4),
|
|
testingAbnormal(5)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Test status.
|
|
Options:
|
|
1. success(1) -indicates normal
|
|
2. fail(2) -indicates abnormal
|
|
3. portbusy(3) -indicates busy port
|
|
4. outoftime(4) -indicates timed-out
|
|
5. testingAbnormal(5) -indicates test abnormal"
|
|
::= { hwSDLMeterTestOprEntry 2 }
|
|
|
|
|
|
hwSDLDMMTestOprTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF HwSDLDMMTestOprEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Operation table for the SDL DMM test:
|
|
It realizes the function of the SDL DMM test in the system.
|
|
In the test, the voltage, resistance, and capacitance of the
|
|
loop line are tested to check for faults such as broken circuit,
|
|
short circuit, grounding and cross-connected line.
|
|
The index of this table is ifIndex"
|
|
::= { hwNTestMIBObjects 25 }
|
|
|
|
hwSDLDMMTestOprEntry OBJECT-TYPE
|
|
SYNTAX HwSDLDMMTestOprEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Operation table for the SDL DMM test:
|
|
It realizes the function of the SDL DMM test in the system.
|
|
In the test, the voltage, resistance, and capacitance of the
|
|
loop line are tested to check for faults such as broken circuit,
|
|
short circuit, grounding and cross-connected line.
|
|
The index of this entry is ifIndex"
|
|
INDEX {
|
|
ifIndex
|
|
}
|
|
::= { hwSDLDMMTestOprTable 1 }
|
|
|
|
HwSDLDMMTestOprEntry ::=
|
|
SEQUENCE
|
|
{
|
|
hwSDLDMMTestOprType INTEGER,
|
|
hwSDLDMMTestVoltage INTEGER,
|
|
hwSDLDMMTestResistance INTEGER,
|
|
hwSDLDMMTestCapacitance INTEGER,
|
|
hwSDLDMMTestStatus INTEGER,
|
|
hwSDLDMMTestConclusion INTEGER,
|
|
hwSDLDMMTestACAG Integer32,
|
|
hwSDLDMMTestACBG Integer32,
|
|
hwSDLDMMTestACAB Integer32,
|
|
hwSDLDMMTestDCAG Integer32,
|
|
hwSDLDMMTestDCBG Integer32,
|
|
hwSDLDMMTestDCAB Integer32,
|
|
hwSDLDMMTestRAG Integer32,
|
|
hwSDLDMMTestRBG Integer32,
|
|
hwSDLDMMTestRAB Integer32,
|
|
hwSDLDMMTestCapAG Integer32,
|
|
hwSDLDMMTestCapBG Integer32,
|
|
hwSDLDMMTestCapAB Integer32
|
|
}
|
|
|
|
hwSDLDMMTestOprType OBJECT-TYPE
|
|
SYNTAX INTEGER{stop(1),start(2)}
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Describes the Operation type.
|
|
Options:
|
|
1. stop(1) -stop the test
|
|
2. start(2) -start the test
|
|
"
|
|
::= { hwSDLDMMTestOprEntry 1 }
|
|
|
|
hwSDLDMMTestVoltage OBJECT-TYPE
|
|
SYNTAX INTEGER{notest(1),test(2)}
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"SDL DMM test-Voltage .
|
|
Options:
|
|
1. notest(1) -no test is applied
|
|
2. test(2) -a test is applied
|
|
"
|
|
::= { hwSDLDMMTestOprEntry 2 }
|
|
|
|
hwSDLDMMTestResistance OBJECT-TYPE
|
|
SYNTAX INTEGER{notest(1),test(2)}
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"SDL DMM test-Resistance.
|
|
Options:
|
|
1. notest(1) -no test is applied
|
|
2. test(2) -a test is applied
|
|
"
|
|
::= { hwSDLDMMTestOprEntry 3 }
|
|
|
|
hwSDLDMMTestCapacitance OBJECT-TYPE
|
|
SYNTAX INTEGER{notest(1),test(2)}
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"SDL DMM test-Capacitance.
|
|
Options:
|
|
1. notest(1) -no test is applied
|
|
2. test(2) -a test is applied
|
|
"
|
|
::= { hwSDLDMMTestOprEntry 4 }
|
|
|
|
hwSDLDMMTestStatus OBJECT-TYPE
|
|
SYNTAX INTEGER{normal(1),abnormal(2),portbusy(3),outoftime(4),testingAbnormal(5)}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Test status.
|
|
Options:
|
|
1. normal(1) -indicates Normal
|
|
2. abnormal(2) -indicates Abnormal
|
|
3. portbusy(3) -indicates Busy port
|
|
4. outoftime(4) -indicates Timed-out
|
|
5. testingAbnormal(5) -indicates Test abnormal
|
|
"
|
|
::= { hwSDLDMMTestOprEntry 5 }
|
|
|
|
hwSDLDMMTestConclusion OBJECT-TYPE
|
|
SYNTAX INTEGER{normal(1),powerline(2),amix(3),bmix(4),abmix(5),agrnd(6),bgrnd(7),abgrnd(8),selfmix(9),
|
|
abpoorinsulation(10),agleak(11),bgleak(12),abgleak(13),abgleak(14),nomodem(15),unknown(16),abgrndorshortlinenoonu(50),onunotexist(51),normalwithonu(52),abmixnoonu(53),singlegndnoonu(54),singlegndwithonu(55),singlecutoff(56)}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Conclusion.
|
|
Options:
|
|
1. normal(1) -indicates Normal
|
|
2. powerline(2) -indicates Contact of power lines
|
|
3. amix(3) -indicates A line mixed with others
|
|
4. bmix(4) -indicates B line mixed with others
|
|
5. abmix(5) -indicates Mixed with others (two lines)
|
|
6. agrnd(6) -indicates A line grounding
|
|
7. bgrnd(7) -indicates B line grounding
|
|
8. abgrnd(8) -indicates A and B grounding
|
|
9. selfmix(9) -indicates Self-mixed (small resistance, self-mixed)
|
|
10. abpoorinsulation(10) -indicates A-B poor insulation
|
|
11. agleak(11) -indicates A-ground leakage
|
|
12. bgleak(12) -indicates B-ground leakage
|
|
13. abgleak(13) -indicates A and B ground leakage
|
|
14. abgleak(14) -indicates A-B leakage
|
|
15. nomodem(15) -indicates Modem not connected
|
|
16. unknown(16) -indicates Unknown
|
|
17. abgrndorshortlinenoonu(50) -indicates A and B grounding or very short line without ONU
|
|
18. onunotexist(51) -indicates ONU not connected
|
|
19. normalwithonu(52) -indicates Normal, ONU04 connected
|
|
20. abmixnoonu(53) -indicates ONU04 not connected and A-B short circuit
|
|
21. singlegndnoonu(54) -indicatess ONU04 not connected, A or B line grounding
|
|
22. singlegndwithonu(55) -indicates ONU04 connected, A or B line grounding
|
|
23. singlecutoff(56) -indicates A or B line is cutoff
|
|
"
|
|
::= { hwSDLDMMTestOprEntry 6 }
|
|
|
|
hwSDLDMMTestACAG OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A->ground AC voltage.
|
|
Unit: millivolt, ab. mV
|
|
"
|
|
::= { hwSDLDMMTestOprEntry 7 }
|
|
|
|
hwSDLDMMTestACBG OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"B->ground AC voltage.
|
|
Unit: millivolt, ab. mV
|
|
"
|
|
::= { hwSDLDMMTestOprEntry 8 }
|
|
|
|
hwSDLDMMTestACAB OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A->B AC voltage.
|
|
Unit: millivolt, ab. mV
|
|
"
|
|
::= { hwSDLDMMTestOprEntry 9 }
|
|
|
|
hwSDLDMMTestDCAG OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A->ground DC voltage.
|
|
Unit: millivolt, ab. mV
|
|
"
|
|
::= { hwSDLDMMTestOprEntry 10 }
|
|
|
|
hwSDLDMMTestDCBG OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"B->ground DC voltage.
|
|
Unit: millivolt, ab. mV
|
|
"
|
|
::= { hwSDLDMMTestOprEntry 11 }
|
|
|
|
hwSDLDMMTestDCAB OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A->B DC voltage.
|
|
Unit: millivolt, ab. mV
|
|
"
|
|
::= { hwSDLDMMTestOprEntry 12 }
|
|
|
|
hwSDLDMMTestRAG OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A->ground insulation resistance.
|
|
Unit: ohm
|
|
"
|
|
::= { hwSDLDMMTestOprEntry 13 }
|
|
|
|
hwSDLDMMTestRBG OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"B->ground insulation resistance.
|
|
Unit: ohm
|
|
"
|
|
::= { hwSDLDMMTestOprEntry 14 }
|
|
|
|
hwSDLDMMTestRAB OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A->B insulation resistance.
|
|
Unit: ohm
|
|
"
|
|
::= { hwSDLDMMTestOprEntry 15 }
|
|
|
|
hwSDLDMMTestCapAG OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A->ground capacitance.
|
|
Unit: nF
|
|
"
|
|
::= { hwSDLDMMTestOprEntry 16 }
|
|
|
|
hwSDLDMMTestCapBG OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"B->ground capacitance.
|
|
Unit: nF
|
|
"
|
|
::= { hwSDLDMMTestOprEntry 17 }
|
|
|
|
hwSDLDMMTestCapAB OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A->B capacitance.
|
|
Unit: nF
|
|
"
|
|
::= { hwSDLDMMTestOprEntry 18 }
|
|
|
|
|
|
hwLoopLineToneOprTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF HwLoopLineToneOprEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Operation table for the loop-line tone test:
|
|
It realizes the function of the test on the circuit and loop-line signals.
|
|
The index of this table is ifIndex.
|
|
"
|
|
::= { hwNTestMIBObjects 26 }
|
|
|
|
|
|
|
|
hwLoopLineToneOprEntry OBJECT-TYPE
|
|
SYNTAX HwLoopLineToneOprEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Operation table for the loop-line tone test:
|
|
It realizes the function of the test on the circuit and loop-line signals.
|
|
The index of this entry is ifIndex.
|
|
"
|
|
INDEX {
|
|
ifIndex
|
|
}
|
|
::= { hwLoopLineToneOprTable 1 }
|
|
|
|
HwLoopLineToneOprEntry ::=
|
|
SEQUENCE {
|
|
hwLoopLineToneOprType
|
|
INTEGER,
|
|
hwLoopLineToneIntensity
|
|
INTEGER,
|
|
hwLoopLineToneBusyFlag
|
|
INTEGER,
|
|
hwLoopLineToneResult
|
|
INTEGER
|
|
}
|
|
|
|
hwLoopLineToneOprType OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
check(1),
|
|
send(2),
|
|
stopsend(3)
|
|
}
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Operation type.
|
|
Options:
|
|
1. check(1) -indicates Detect the signal tone
|
|
2. send(2) -indicates Send the signal tone
|
|
3. stopsend(3) -indicates Stop sending the signal tone)
|
|
"
|
|
::= { hwLoopLineToneOprEntry 1 }
|
|
|
|
hwLoopLineToneIntensity OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
fivedB(1),
|
|
tendB(2),
|
|
fifteendB(3)
|
|
}
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Signal tone intensity.
|
|
Options:
|
|
1. fivedB(1) -indicates 5 dB
|
|
2. tendB(2) -indicates 10 dB
|
|
3. fifteendB(3) -indicates 15 dB
|
|
"
|
|
::= { hwLoopLineToneOprEntry 2 }
|
|
|
|
hwLoopLineToneBusyFlag OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
busynotest(1),
|
|
busystrentest(2)
|
|
}
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Busy control flag.
|
|
Options:
|
|
1. busynotest(1) -indicates no test when busy
|
|
2. busystrentest(2) -indicates Forced test when busy
|
|
"
|
|
::= { hwLoopLineToneOprEntry 3 }
|
|
|
|
hwLoopLineToneResult OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
succeed(1),
|
|
failed(2)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Operation result.
|
|
Options:
|
|
1. succeed(1) -indicates successful
|
|
2. failed(2) -indicates failed
|
|
"
|
|
::= { hwLoopLineToneOprEntry 4 }
|
|
|
|
|
|
hwPotsSelfCircuitTestOprTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF HwPotsSelfCircuitTestOprEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Operation table for the PSTN subscriber circuit test.
|
|
The index of this table is ifIndex."
|
|
::= { hwNTestMIBObjects 27 }
|
|
|
|
hwPotsSelfCircuitTestOprEntry OBJECT-TYPE
|
|
SYNTAX HwPotsSelfCircuitTestOprEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Operation table for the PSTN subscriber circuit test.
|
|
The index of this entry is ifIndex."
|
|
INDEX {
|
|
ifIndex
|
|
}
|
|
::= { hwPotsSelfCircuitTestOprTable 1 }
|
|
|
|
HwPotsSelfCircuitTestOprEntry ::=
|
|
SEQUENCE
|
|
{
|
|
hwPotsSelfCircuitTestOprType INTEGER,
|
|
hwPotsSelfCircuitTestBusyProcFlag INTEGER,
|
|
hwPotsSelfCircuitTestStatus INTEGER,
|
|
hwPotsSelfCircuitTestVDDResult INTEGER,
|
|
hwPotsSelfCircuitTestVBATLResult INTEGER,
|
|
hwPotsSelfCircuitTestVBATHResult INTEGER,
|
|
hwPotsSelfCircuitTestVBATRResult INTEGER,
|
|
hwPotsSelfCircuitTestLoopCurrentResult INTEGER,
|
|
hwPotsSelfCircuitTestFeedVResult INTEGER,
|
|
hwPotsSelfCircuitTestRingVResult INTEGER,
|
|
hwPotsSelfCircuitTestRingFResult INTEGER,
|
|
hwPotsSelfCircuitTestVAGResult INTEGER,
|
|
hwPotsSelfCircuitTestVBGResult INTEGER,
|
|
hwPotsSelfCircuitTestDeferredTime Integer32,
|
|
hwPotsSelfCircuitTestTimeoutProc INTEGER,
|
|
hwPotsSelfCircuitTestFeedVValue Integer32,
|
|
hwPotsSelfCircuitTestRingVValue Integer32,
|
|
hwPotsSelfCircuitTestLoopCurrentValue Integer32,
|
|
hwPotsSelfCircuitTestLoopIfIndex Integer32,
|
|
hwPotsSelfCircuitTestLoopRequestID Integer32,
|
|
hwPotsSelfCircuitTestOnHookDetectResult INTEGER,
|
|
hwPotsSelfCircuitTestOffHookDetectResult INTEGER,
|
|
hwPotsSelfCircuitTestStopRingResult INTEGER,
|
|
hwPotsSelfCircuitTestVPoleResult INTEGER,
|
|
hwPotsSelfCircuitTestVBATLValue Integer32,
|
|
hwPotsSelfCircuitTestVBATHValue Integer32,
|
|
hwPotsSelfCircuitTestVBATRValue Integer32,
|
|
hwPotsSelfCircuitTestRingFValue Integer32,
|
|
hwPotsSelfCircuitTestVAGValue Integer32,
|
|
hwPotsSelfCircuitTestVBGValue Integer32,
|
|
hwPotsSelfCircuitTestVABPoleValue Integer32,
|
|
hwPotsSelfCircuitTestABLCurrentValue Integer32,
|
|
hwPotsSelfCircuitTestSLICTempValue Integer32
|
|
}
|
|
|
|
hwPotsSelfCircuitTestOprType OBJECT-TYPE
|
|
SYNTAX INTEGER{stop(1),start(2)}
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Circuit test-Operation type.
|
|
Options:
|
|
1. stop(1) -stop the test
|
|
2. start(2) -start the test
|
|
"
|
|
::= { hwPotsSelfCircuitTestOprEntry 1 }
|
|
|
|
hwPotsSelfCircuitTestBusyProcFlag OBJECT-TYPE
|
|
SYNTAX INTEGER{busynotest(1),busytest(2),busystrentest(3),deferredtest(4)}
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Circuit test-Busy control.
|
|
Options:
|
|
1. busynotest(1) -indicates no test when busy
|
|
2. busytest(2) -indicates remedy test when busy
|
|
3. busystrentest(3) -indicates force to test when busy
|
|
4. deferredtest(4) -indicates defer test when busy:
|
|
If the port is busy, the test operation will be deferred. If the port changes to idle state before
|
|
time out, circuit test will be executed immediately. If the port keeps busy by the time out,
|
|
the system will excecute a corresponding operation according to what the user specified: canceling
|
|
the test or forcing to test.
|
|
If the value of this leaf node is deferredtest(4), both hwPotsSelfCircuitTestDeferredTime and
|
|
hwPotsSelfCircuitTestTimeoutProc must be set."
|
|
::= { hwPotsSelfCircuitTestOprEntry 2 }
|
|
|
|
hwPotsSelfCircuitTestStatus OBJECT-TYPE
|
|
SYNTAX INTEGER{normal(1),testfail(2),portbusy(3),outoftime(4),testingAbnormal(5),testcanceled(6)}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Circuit test-Test status.
|
|
Options:
|
|
1. normal(1) -indicates Normal
|
|
2. testfail(2) -indicates Abnormal
|
|
3. portbusy(3) -indicates Busy port
|
|
4. outoftime(4) -indicates Timed-out
|
|
5. testingAbnormal(5) -indicates Test abnormal
|
|
6. testcanceled(6) -indicates Test is canceled
|
|
"
|
|
::= { hwPotsSelfCircuitTestOprEntry 3 }
|
|
|
|
hwPotsSelfCircuitTestVDDResult OBJECT-TYPE
|
|
SYNTAX INTEGER{normal(1),abnormal(2),notsupport(3)}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Circuit test result-VDD result.
|
|
Options:
|
|
1. normal(1) -indicates the test result is normal
|
|
2. abnormal(2) -indicates the test result is abnormal
|
|
3. notsupport(3) -indicates the test result is notsupport
|
|
"
|
|
::= { hwPotsSelfCircuitTestOprEntry 4 }
|
|
|
|
hwPotsSelfCircuitTestVBATLResult OBJECT-TYPE
|
|
SYNTAX INTEGER{normal(1),abnormal(2),notsupport(3)}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Circuit test result-VBATL result.
|
|
Options:
|
|
1. normal(1) -indicates the test result is normal
|
|
2. abnormal(2) -indicates the test result is abnormal
|
|
3. notsupport(3) -indicates the test result is notsupport
|
|
"
|
|
::= { hwPotsSelfCircuitTestOprEntry 5 }
|
|
|
|
hwPotsSelfCircuitTestVBATHResult OBJECT-TYPE
|
|
SYNTAX INTEGER{normal(1),abnormal(2),notsupport(3)}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Circuit test result-VBATH result.
|
|
Options:
|
|
1. normal(1) -indicates the test result is normal
|
|
2. abnormal(2) -indicates the test result is abnormal
|
|
3. notsupport(3) -indicates the test result is notsupport
|
|
"
|
|
::= { hwPotsSelfCircuitTestOprEntry 6 }
|
|
|
|
hwPotsSelfCircuitTestVBATRResult OBJECT-TYPE
|
|
SYNTAX INTEGER{normal(1),abnormal(2),notsupport(3)}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Circuit test result-VBATR result.
|
|
Options:
|
|
1. normal(1) -indicates the test result is normal
|
|
2. abnormal(2) -indicates the test result is abnormal
|
|
3. notsupport(3) -indicates the test result is notsupport
|
|
"
|
|
::= { hwPotsSelfCircuitTestOprEntry 7 }
|
|
|
|
hwPotsSelfCircuitTestLoopCurrentResult OBJECT-TYPE
|
|
SYNTAX INTEGER{normal(1),abnormal(2),notsupport(3)}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Circuit test result-Loop current result.
|
|
Options:
|
|
1. normal(1) -indicates the test result is normal
|
|
2. abnormal(2) -indicates the test result is abnormal
|
|
3. notsupport(3) -indicates the test result is notsupport
|
|
"
|
|
::= { hwPotsSelfCircuitTestOprEntry 8 }
|
|
|
|
hwPotsSelfCircuitTestFeedVResult OBJECT-TYPE
|
|
SYNTAX INTEGER{normal(1),abnormal(2),notsupport(3)}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Circuit test result-Feeder voltage result.
|
|
Options:
|
|
1. normal(1) -indicates the test result is normal
|
|
2. abnormal(2) -indicates the test result is abnormal
|
|
3. notsupport(3) -indicates the test result is notsupport
|
|
"
|
|
::= { hwPotsSelfCircuitTestOprEntry 9 }
|
|
|
|
hwPotsSelfCircuitTestRingVResult OBJECT-TYPE
|
|
SYNTAX INTEGER{normal(1),abnormal(2),notsupport(3)}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Circuit test result-Ring voltage result.
|
|
Options:
|
|
1. normal(1) -indicates the test result is normal
|
|
2. abnormal(2) -indicates the test result is abnormal
|
|
3. notsupport(3) -indicates the test result is notsupport
|
|
"
|
|
::= { hwPotsSelfCircuitTestOprEntry 10 }
|
|
|
|
hwPotsSelfCircuitTestRingFResult OBJECT-TYPE
|
|
SYNTAX INTEGER{normal(1),abnormal(2),notsupport(3)}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Circuit test result-Ring frequency result.
|
|
Options:
|
|
1. normal(1) -indicates the test result is normal
|
|
2. abnormal(2) -indicates the test result is abnormal
|
|
3. notsupport(3) -indicates the test result is notsupport
|
|
"
|
|
::= { hwPotsSelfCircuitTestOprEntry 11 }
|
|
|
|
hwPotsSelfCircuitTestVAGResult OBJECT-TYPE
|
|
SYNTAX INTEGER{normal(1),abnormal(2),notsupport(3)}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Circuit test result-A->ground voltage result.
|
|
Options:
|
|
1. normal(1) -indicates the test result is normal
|
|
2. abnormal(2) -indicates the test result is abnormal
|
|
3. notsupport(3) -indicates the test result is notsupport
|
|
"
|
|
::= { hwPotsSelfCircuitTestOprEntry 12 }
|
|
|
|
hwPotsSelfCircuitTestVBGResult OBJECT-TYPE
|
|
SYNTAX INTEGER{normal(1),abnormal(2),notsupport(3)}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Circuit test result-B->ground voltage result.
|
|
Options:
|
|
1. normal(1) -indicates the test result is normal
|
|
2. abnormal(2) -indicates the test result is abnormal
|
|
3. notsupport(3) -indicates the test result is notsupport
|
|
"
|
|
::= { hwPotsSelfCircuitTestOprEntry 13 }
|
|
|
|
hwPotsSelfCircuitTestDeferredTime OBJECT-TYPE
|
|
SYNTAX Integer32(-1 | 1..1440)
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"deferred time
|
|
Unit: minute
|
|
this leaf node is valid only when the value of hwPotsSelfCircuitTestBusyProcFlag is deferredtest(4).
|
|
Default: 30(minute).
|
|
"
|
|
DEFVAL { 30 }
|
|
::= { hwPotsSelfCircuitTestOprEntry 14 }
|
|
|
|
hwPotsSelfCircuitTestTimeoutProc OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
notest(1),
|
|
test(2)
|
|
}
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"timeout proc:
|
|
Options:
|
|
1. notest(1) -indicates when deferred time out, if the port is still busy, test will be canceled
|
|
2. test(2) -indicates when deferred time out, if the port is still busy, test will be preformed by force.
|
|
this leaf node is valid only when the value of hwPotsSelfCircuitTestBusyProcFlag is deferredtest(4).
|
|
Default: notest(1)."
|
|
DEFVAL { 1 }
|
|
::= { hwPotsSelfCircuitTestOprEntry 15 }
|
|
|
|
hwPotsSelfCircuitTestFeedVValue OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Circuit Test Result-Feeder voltage
|
|
Unit: millivolt, mV
|
|
"
|
|
::= { hwPotsSelfCircuitTestOprEntry 16 }
|
|
|
|
hwPotsSelfCircuitTestRingVValue OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Circuit Test Result-Ringing current voltage
|
|
Unit: millivolt, mV
|
|
"
|
|
::= { hwPotsSelfCircuitTestOprEntry 17 }
|
|
|
|
hwPotsSelfCircuitTestLoopCurrentValue OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Circuit Test Result-Loop current
|
|
Unit: millivolt, mV
|
|
"
|
|
::= { hwPotsSelfCircuitTestOprEntry 18 }
|
|
|
|
hwPotsSelfCircuitTestLoopIfIndex OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Port Index"
|
|
::= { hwPotsSelfCircuitTestOprEntry 19 }
|
|
|
|
hwPotsSelfCircuitTestLoopRequestID OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Request ID"
|
|
::= { hwPotsSelfCircuitTestOprEntry 20 }
|
|
|
|
hwPotsSelfCircuitTestOnHookDetectResult OBJECT-TYPE
|
|
SYNTAX INTEGER{normal(1),abnormal(2),notsupport(3)}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Circuit test OnHookDetect result.
|
|
Options:
|
|
1. normal(1) -indicates the test result is normal
|
|
2. abnormal(2) -indicates the test result is abnormal
|
|
3. notsupport(3) -indicates the test result is notsupport
|
|
"
|
|
::= { hwPotsSelfCircuitTestOprEntry 21 }
|
|
|
|
hwPotsSelfCircuitTestOffHookDetectResult OBJECT-TYPE
|
|
SYNTAX INTEGER{normal(1),abnormal(2),notsupport(3)}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Circuit test OffHookDetect result.
|
|
Options:
|
|
1. normal(1) -indicates the test result is normal
|
|
2. abnormal(2) -indicates the test result is abnormal
|
|
3. notsupport(3) -indicates the test result is notsupport
|
|
"
|
|
::= { hwPotsSelfCircuitTestOprEntry 22 }
|
|
|
|
hwPotsSelfCircuitTestStopRingResult OBJECT-TYPE
|
|
SYNTAX INTEGER{normal(1),abnormal(2),notsupport(3)}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Circuit test StopRing result.
|
|
Options:
|
|
1. normal(1) -indicates the test result is normal
|
|
2. abnormal(2) -indicates the test result is abnormal
|
|
3. notsupport(3) -indicates the test result is notsupport
|
|
"
|
|
::= { hwPotsSelfCircuitTestOprEntry 23 }
|
|
|
|
hwPotsSelfCircuitTestVPoleResult OBJECT-TYPE
|
|
SYNTAX INTEGER{normal(1),abnormal(2),notsupport(3)}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Circuit test VPole result.
|
|
Options:
|
|
1. normal(1) -indicates the test result is normal
|
|
2. abnormal(2) -indicates the test result is abnormal
|
|
3. notsupport(3) -indicates the test result is notsupport
|
|
"
|
|
::= { hwPotsSelfCircuitTestOprEntry 24 }
|
|
|
|
hwPotsSelfCircuitTestVBATLValue OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Circuit Test VBATL Value
|
|
Unit: mV
|
|
"
|
|
::= { hwPotsSelfCircuitTestOprEntry 25 }
|
|
|
|
hwPotsSelfCircuitTestVBATHValue OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Circuit Test VBATH Value
|
|
Unit: mV
|
|
"
|
|
::= { hwPotsSelfCircuitTestOprEntry 26 }
|
|
|
|
hwPotsSelfCircuitTestVBATRValue OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Circuit Test VBATR Value
|
|
Unit: mV
|
|
"
|
|
::= { hwPotsSelfCircuitTestOprEntry 27 }
|
|
|
|
hwPotsSelfCircuitTestRingFValue OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Circuit Test Ring Frequency Value
|
|
Unit: HZ
|
|
"
|
|
::= { hwPotsSelfCircuitTestOprEntry 28 }
|
|
|
|
hwPotsSelfCircuitTestVAGValue OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Circuit Test A->Ground Value
|
|
Unit: mV
|
|
"
|
|
::= { hwPotsSelfCircuitTestOprEntry 29 }
|
|
|
|
hwPotsSelfCircuitTestVBGValue OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Circuit Test B->Ground Value
|
|
Unit: mV
|
|
"
|
|
::= { hwPotsSelfCircuitTestOprEntry 30 }
|
|
|
|
hwPotsSelfCircuitTestVABPoleValue OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Circuit Test A->B Pole Voltage Value
|
|
Unit: mV
|
|
"
|
|
::= { hwPotsSelfCircuitTestOprEntry 31 }
|
|
|
|
hwPotsSelfCircuitTestABLCurrentValue OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Circuit Test A->B Current Value
|
|
Unit: uA
|
|
"
|
|
::= { hwPotsSelfCircuitTestOprEntry 32 }
|
|
|
|
hwPotsSelfCircuitTestSLICTempValue OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Circuit SLIC Temp Value
|
|
Unit: oC
|
|
"
|
|
::= { hwPotsSelfCircuitTestOprEntry 33 }
|
|
|
|
|
|
hwPstnCircuitTestTrap NOTIFICATION-TYPE
|
|
OBJECTS { hwPstnCircuitTestStatus,
|
|
hwPstnCircuitTestOffHookResult,
|
|
hwPstnCircuitTestDialToneResult,
|
|
hwPstnCircuitTestReceivePulseResult,
|
|
hwPstnCircuitTestReceiveDTMFResult,
|
|
hwPstnCircuitTestRingBackResult,
|
|
hwPstnCircuitTestBusyToneResult,
|
|
hwPstnCircuitTestBatteryFeedResult,
|
|
hwPstnCircuitTestPoleDetectResult,
|
|
hwPstnCircuitTestOnHookResult,
|
|
hwPstnCircuitTestRingResult,
|
|
hwPstnCircuitTestStopRingResult,
|
|
hwPstnCircuitTestFeedVValue,
|
|
hwPstnCircuitTestFeedVResult,
|
|
hwPstnCircuitTestRingVValue,
|
|
hwPstnCircuitTestRingVResult,
|
|
hwPstnCircuitTestLoopCurrentValue,
|
|
hwPstnCircuitTestLoopCurrentResult }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"PSTN subscriber circuit test result trap:
|
|
1. hwPstnCircuitTestStatus
|
|
2. hwPstnCircuitTestOffHookResult
|
|
3. hwPstnCircuitTestDialToneResult
|
|
4. hwPstnCircuitTestReceivePulseResult
|
|
5. hwPstnCircuitTestReceiveDTMFResult
|
|
6. hwPstnCircuitTestRingBackResult
|
|
7. hwPstnCircuitTestBusyToneResult
|
|
8. hwPstnCircuitTestBatteryFeedResult
|
|
9. hwPstnCircuitTestPoleDetectResult
|
|
10. hwPstnCircuitTestOnHookResult
|
|
11. hwPstnCircuitTestRingResult
|
|
12. hwPstnCircuitTestStopRingResult
|
|
13. hwPstnCircuitTestFeedVValue
|
|
14. hwPstnCircuitTestFeedVResult
|
|
15. hwPstnCircuitTestRingVValue
|
|
16. hwPstnCircuitTestRingVResult
|
|
17. hwPstnCircuitTestLoopCurrentValue
|
|
18. hwPstnCircuitTestLoopCurrentResult"
|
|
::= { hwNTestGeneralTrapsOIDs 50 }
|
|
|
|
hw112UserRingTestTrap NOTIFICATION-TYPE
|
|
OBJECTS { hw112UserRingTestResult }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This notification indicates that the 112 PSTN subscriber ring test result trap: 1: hw112UserRingTestResult"
|
|
::= { hwNTestGeneralTrapsOIDs 51 }
|
|
|
|
hw112UserDialTestTrap NOTIFICATION-TYPE
|
|
OBJECTS { hw112UserDialTestResult,hw112UserDialTestDigit,hw112UserDialTestLowLevel,hw112UserDialTestHighLevel,hw112UserDialTestLowFreq,hw112UserDialTestHighFreq,hw112UserDialTestPulseLen,hw112UserDialTestMakeDur,hw112UserDialTestBreakDur }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This notification indicates the 112 PSTN subscriber dial test result trap:
|
|
1: hw112UserDialTestResult;
|
|
2: hw112UserDialTestDigit;
|
|
3: hw112UserDialTestLowLevel;
|
|
4: hw112UserDialTestHighLevel;
|
|
5: hw112UserDialTestLowFreq;
|
|
6: hw112UserDialTestHighFreq;
|
|
7: hw112UserDialTestPulseLen;
|
|
8: hw112UserDialTestMakeDur;
|
|
9: hw112UserDialTestBreakDur"
|
|
::= { hwNTestGeneralTrapsOIDs 52 }
|
|
|
|
hw112UserHowlerTestTrap NOTIFICATION-TYPE
|
|
OBJECTS { hw112UserHowlerTestResult }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This notification indicates that the 112 PSTN subscriber howler test result trap: 1:hw112UserHowlerTestResult"
|
|
::= { hwNTestGeneralTrapsOIDs 53 }
|
|
|
|
|
|
hwIsdnUserInTestTrap NOTIFICATION-TYPE
|
|
OBJECTS { hwIsdnUserInTestStatus,hwIsdnUserInTestActiveResult,hwIsdnUserInTestDeactiveResult,hwIsdnUserInTestLtSupplyPowerCap,hwIsdnUserInTestLtSupplyPowerCapResult,hwIsdnUserInTestLtCurrentProctectResult,hwIsdnUserInTestCutLineVolVal,hwIsdnUserInTestCutLineVolResult,hwIsdnUserInTestSwitchOnVolVal,hwIsdnUserInTestSwitchOnVolResult }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This notification indicates the ISDN subscriber circuit test result trap:
|
|
1: hwIsdnUserInTestStatus;
|
|
2: hwIsdnUserInTestActiveResult;
|
|
3: hwIsdnUserInTestDeactiveResult;
|
|
4: hwIsdnUserInTestLtSupplyPowerCap;
|
|
5: hwIsdnUserInTestLtSupplyPowerCapResult;
|
|
6: hwIsdnUserInTestLtCurrentProctectResult;
|
|
7: hwIsdnUserInTestCutLineVolVal;
|
|
8: hwIsdnUserInTestCutLineVolResult;
|
|
9: hwIsdnUserInTestSwitchOnVolVal;
|
|
10: hwIsdnUserInTestSwitchOnVolResult
|
|
"
|
|
::= { hwNTestGeneralTrapsOIDs 54 }
|
|
|
|
hwIsdnUserOutTestTrap NOTIFICATION-TYPE
|
|
OBJECTS { hwIsdnUserOutTestStatus,hwIsdnUserOutTestActNT1Result,hwIsdnUserOutTestDeactNT1Result,hwIsdnUserOutTestTransBitErrorResult,hwIsdnUserOutTestTotalSend,hwIsdnUserOutTestCodeErrorNumber,hwIsdnUserOutTestCodeErrorRate }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This notification indicates that the ISDN subscriber loop-line test result trap:
|
|
1: hwIsdnUserOutTestStatus;
|
|
2: hwIsdnUserOutTestActNT1Result;
|
|
3: hwIsdnUserOutTestDeactNT1Result;
|
|
4: hwIsdnUserOutTestTransBitErrorResult;
|
|
5: hwIsdnUserOutTestTotalSend;
|
|
6: hwIsdnUserOutTestCodeErrorNumber;
|
|
7: hwIsdnUserOutTestCodeErrorRate"
|
|
::= { hwNTestGeneralTrapsOIDs 55 }
|
|
|
|
hwIsdnUserOutLineTestTrap NOTIFICATION-TYPE
|
|
OBJECTS { hwIsdnUserOutLineTestStatus,hwIsdnUserOutLineTestConclusion,hwIsdnUserOutLineTestACAG,hwIsdnUserOutLineTestACBG,hwIsdnUserOutLineTestACAB,hwIsdnUserOutLineTestDCAG,hwIsdnUserOutLineTestDCBG,hwIsdnUserOutLineTestDCAB,hwIsdnUserOutLineTestRAG,hwIsdnUserOutLineTestRBG,hwIsdnUserOutLineTestRAB,hwIsdnUserOutLineTestCapAG,hwIsdnUserOutLineTestCapBG,hwIsdnUserOutLineTestCapAB,hwIsdnUserOutLineTestImpedanceAB,hwIsdnUserOutLineTestImpedanceBA,hwIsdnUserOutLineTestImpedanceAG,hwIsdnUserOutLineTestImpedanceBG,hwIsdnUserOutLineTestACCurrentAG,hwIsdnUserOutLineTestACCurrentBG,hwIsdnUserOutLineTestACCurrentAB,hwIsdnUserOutLineTestDCCurrentAG,hwIsdnUserOutLineTestDCCurrentBG,hwIsdnUserOutLineTestDCCurrentAB,hwIsdnUserOutLineTestLC,hwIsdnUserOutLineTestN }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This notification indicates that the ISDN subscriber loop-line test result trap:
|
|
1: hwIsdnUserOutLineTestStatus;
|
|
2: hwIsdnUserOutLineTestConclusion;
|
|
3: hwIsdnUserOutLineTestACAG;
|
|
4: hwIsdnUserOutLineTestACBG;
|
|
5: hwIsdnUserOutLineTestACAB;
|
|
6: hwIsdnUserOutLineTestDCAG;
|
|
7: hwIsdnUserOutLineTestDCBG;
|
|
8: hwIsdnUserOutLineTestDCAB;
|
|
9: hwIsdnUserOutLineTestRAG;
|
|
10: hwIsdnUserOutLineTestRBG;
|
|
11: hwIsdnUserOutLineTestRAB;
|
|
12: hwIsdnUserOutLineTestCapAG;
|
|
13: hwIsdnUserOutLineTestCapBG;
|
|
14: hwIsdnUserOutLineTestCapAB;
|
|
15: hwIsdnUserOutLineTestImpedanceAB;
|
|
16: hwIsdnUserOutLineTestImpedanceBA;
|
|
17: hwIsdnUserOutLineTestImpedanceAG;
|
|
18: hwIsdnUserOutLineTestImpedanceBG;
|
|
19: hwIsdnUserOutLineTestACCurrentAG;
|
|
20: hwIsdnUserOutLineTestACCurrentBG;
|
|
21: hwIsdnUserOutLineTestACCurrentAB;
|
|
22: hwIsdnUserOutLineTestDCCurrentAG;
|
|
23: hwIsdnUserOutLineTestDCCurrentBG;
|
|
24: hwIsdnUserOutLineTestDCCurrentAB;
|
|
25: hwIsdnUserOutLineTestLC;
|
|
26: hwIsdnUserOutLineTestN"
|
|
::= { hwNTestGeneralTrapsOIDs 56 }
|
|
|
|
hwIsdnPortStateSwitchTestTrap NOTIFICATION-TYPE
|
|
OBJECTS { hwIsdnPortStateSwitchTestStatus }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This notification indicates that the trap for the result of switching the ISDN subscriber port: 1: hwIsdnPortStateSwitchTestStatus"
|
|
::= { hwNTestGeneralTrapsOIDs 57 }
|
|
|
|
hw112IsdnDiagnoseTrap NOTIFICATION-TYPE
|
|
OBJECTS { hw112IsdnDiagnoseTestRequestID, hw112IsdnDiagnoseTestResult, hw112IsdnDiagnoseTestIfIndex }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This notification indicates that the trap for the result of 112 ISDN subscriber diagnosis test:
|
|
1: hw112IsdnDiagnoseTestRequestID;
|
|
2: hw112IsdnDiagnoseTestResult;
|
|
3: hw112IsdnDiagnoseTestIfIndex"
|
|
::= { hwNTestGeneralTrapsOIDs 58 }
|
|
|
|
hwPstnCallerEmulateOperatorTrap NOTIFICATION-TYPE
|
|
OBJECTS { hwPstnCallerEmulateTestRequestID,hwPstnCallerEmulateTestStatus,hwPstnCallerEmulateTestResult,ifIndex }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This notification indicates that the trap for the result of the PSTN call emulation test (calling party):
|
|
1: hwPstnCallerEmulateTestRequestID
|
|
2: hwPstnCallerEmulateTestStatus
|
|
3: hwPstnCallerEmulateTestResult
|
|
4: ifIndex"
|
|
::= { hwNTestGeneralTrapsOIDs 59 }
|
|
|
|
hwPstnCalledEmulateOperatorTrap NOTIFICATION-TYPE
|
|
OBJECTS { hwPstnCalledEmulateTestRequestID,hwPstnCalledEmulateTestStatus,hwPstnCalledEmulateTestResult,ifIndex }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This notification indicates that the trap for the result of the PSTN call emulation test (called party):
|
|
1: hwPstnCalledEmulateTestRequestID
|
|
2: hwPstnCalledEmulateTestStatus
|
|
3: hwPstnCalledEmulateTestResult
|
|
4: ifIndex"
|
|
::= { hwNTestGeneralTrapsOIDs 60 }
|
|
|
|
hwPstnTelephoneTestOperatorTrap NOTIFICATION-TYPE
|
|
OBJECTS { hwPstnTelephoneTestStatus,hwPstnTelephoneTestLoopResist,hwPstnTelephoneTestHookingTime,hwPstnTelephoneTestReverse,hwPstnTelephoneTestDialDigit,hwPstnTelephoneTestPulseLen,hwPstnTelephoneTestMakeDur,hwPstnTelephoneTestBreakDur,hwPstnTelephoneTestAssisTelno }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This notification indicates that the trap for the result of the PSTN telephone test:
|
|
1: hwPstnTelephoneTestStatus;
|
|
2: hwPstnTelephoneTestLoopResist;
|
|
3: hwPstnTelephoneTestHookingTime;
|
|
4: hwPstnTelephoneTestReverse;
|
|
5: hwPstnTelephoneTestDialDigit;
|
|
6: hwPstnTelephoneTestPulseLen;
|
|
7: hwPstnTelephoneTestMakeDur;
|
|
8: hwPstnTelephoneTestBreakDur;
|
|
9: hwPstnTelephoneTestAssisTelno"
|
|
::= { hwNTestGeneralTrapsOIDs 61 }
|
|
|
|
hwIsdnUserDiagnoseTestOperatorTrap NOTIFICATION-TYPE
|
|
OBJECTS { hwIsdnUserDiagnoseTestStatus }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This notification indicates that the trap for the ISDN subscriber diagnosis test:
|
|
1: hwIsdnUserDiagnoseTestStatus"
|
|
::= { hwNTestGeneralTrapsOIDs 62 }
|
|
|
|
hwPstnSignalToneTestOperatorTrap NOTIFICATION-TYPE
|
|
OBJECTS { hwPstnSignalToneTestRequestID, hwPstnSignalToneTestResult, hwPstnSignalToneTestDTDelayTime, ifIndex, hwPstnSignalToneActualDeferTime, hwPstnSignalToneTestDTStop }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This notification indicates that the trap for the result of the PSTN signal tone test:
|
|
1: hwPstnSignalToneTestRequestID;
|
|
2: hwPstnSignalToneTestResult;
|
|
3: hwPstnSignalToneTestDTDelayTime;
|
|
4: ifIndex;
|
|
5: hwPstnSignalToneActualDeferTime;
|
|
6: hwPstnSignalToneTestDTStop"
|
|
::= { hwNTestGeneralTrapsOIDs 63 }
|
|
|
|
hwIsdnMeterTestOperatorTrap NOTIFICATION-TYPE
|
|
OBJECTS { hwIsdnMeterTestStatus }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This notification indicates that the trap for the result of the ISDN meter test:
|
|
1: hwIsdnMeterTestStatus"
|
|
::= { hwNTestGeneralTrapsOIDs 64 }
|
|
|
|
|
|
hwTestBusTestTrap NOTIFICATION-TYPE
|
|
OBJECTS { hwTestBusTestResult, hwTestBusTestVoltage, hwTestBusTestResistance, hwTestBusTestCapacitance }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This notification indicates that the trap for the result of the bus test:
|
|
1: hwTestBusTestResult;
|
|
2: hwTestBusTestVoltage;
|
|
3: hwTestBusTestResistance;
|
|
4: hwTestBusTestCapacitance"
|
|
::= { hwNTestGeneralTrapsOIDs 65 }
|
|
|
|
hwFrameLooplineAdjustTrap NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
hwFrameLooplineAdjustRequestID,
|
|
hwFrameLooplineAdjustResult,
|
|
hwFrameLooplineAdjustOprCab,
|
|
hwFrameLooplineAdjustOprCag,
|
|
hwFrameLooplineAdjustOprCbg,
|
|
hwFrameLooplineAdjustOprRab,
|
|
hwFrameLooplineAdjustFrameIndex
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This notification indicates that the trap for the result of the loop-line test calibration value:
|
|
1: hwFrameLooplineAdjustRequestID;
|
|
2: hwFrameLooplineAdjustResult;
|
|
3: hwFrameLooplineAdjustOprCab;
|
|
4: hwFrameLooplineAdjustOprCag;
|
|
5: hwFrameLooplineAdjustOprCbg;
|
|
6: hwFrameLooplineAdjustOprRab;
|
|
7: hwFrameLooplineAdjustFrameIndex"
|
|
::= { hwNTestGeneralTrapsOIDs 66 }
|
|
|
|
hwSDLMeterTestOperatorTrap NOTIFICATION-TYPE
|
|
OBJECTS { hwSDLMeterTestStatus }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This notification indicates that the trap for the result of the SDL meter test: 1: hwSDLMeterTestStatus"
|
|
::= { hwNTestGeneralTrapsOIDs 67 }
|
|
|
|
hwSDLDMMTestTrap NOTIFICATION-TYPE
|
|
OBJECTS { hwSDLDMMTestStatus,hwSDLDMMTestConclusion,hwSDLDMMTestACAG,hwSDLDMMTestACBG,hwSDLDMMTestACAB,hwSDLDMMTestDCAG,hwSDLDMMTestDCBG,hwSDLDMMTestDCAB,hwSDLDMMTestRAG,hwSDLDMMTestRBG,hwSDLDMMTestRAB,hwSDLDMMTestCapAG,hwSDLDMMTestCapBG,hwSDLDMMTestCapAB }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This notification indicates that the trap for the result of the SDL DMM test:
|
|
1:hwSDLDMMTestStatus;
|
|
2: hwSDLDMMTestConclusion;
|
|
3: hwSDLDMMTestACAG;
|
|
4: hwSDLDMMTestACBG;
|
|
5: hwSDLDMMTestACAB;
|
|
6: hwSDLDMMTestDCAG;
|
|
7: hwSDLDMMTestDCBG;
|
|
8: hwSDLDMMTestDCAB;
|
|
9: hwSDLDMMTestRAG;
|
|
10: hwSDLDMMTestRBG;
|
|
11: hwSDLDMMTestRAB;
|
|
12: hwSDLDMMTestCapAG;
|
|
13: hwSDLDMMTestCapBG;
|
|
14: hwSDLDMMTestCapAB"
|
|
::= { hwNTestGeneralTrapsOIDs 68 }
|
|
|
|
hwQosTestOperatorTrap NOTIFICATION-TYPE
|
|
OBJECTS { hwQosTestIndex, hwQosTestGWAddr, hwQosTestPeerAddr,
|
|
hwQosTestInPkts, hwQosTestOutPkts, hwQosTestInOctets, hwQosTestOutOctets, hwQosTestInDropPkts,
|
|
hwQosTestStatsMaxDropPktsRate, hwQosTestStatsMaxDropPktsPort,
|
|
hwQosTestStatsMinDropPktsRate, hwQosTestStatsMinDropPktsPort,
|
|
hwQosTestStatsMaxDitherDelay, hwQosTestStatsMaxDitherPort,
|
|
hwQosTestStatsMinDitherDelay, hwQosTestStatsMinDitherPort,
|
|
hwQosTestStatsMaxLoopDelay, hwQosTestStatsMaxLoopPort,
|
|
hwQosTestStatsMinLoopDelay, hwQosTestStatsMinLoopPort
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This notification indicates that the trap for the QoS test result"
|
|
::= { hwNTestGeneralTrapsOIDs 69 }
|
|
|
|
hwLoopLineToneOperatorTrap NOTIFICATION-TYPE
|
|
OBJECTS { hwLoopLineToneResult }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This notification indicates that the trap for the result of the signal tone test: 1: hwLoopLineToneResult"
|
|
::= { hwNTestGeneralTrapsOIDs 70 }
|
|
|
|
hwPotsSelfCircuitTestTrap NOTIFICATION-TYPE
|
|
OBJECTS { hwPotsSelfCircuitTestLoopRequestID,
|
|
hwPotsSelfCircuitTestStatus,
|
|
hwPotsSelfCircuitTestVDDResult,
|
|
hwPotsSelfCircuitTestVBATLResult,
|
|
hwPotsSelfCircuitTestVBATHResult,
|
|
hwPotsSelfCircuitTestVBATRResult,
|
|
hwPotsSelfCircuitTestLoopCurrentResult,
|
|
hwPotsSelfCircuitTestFeedVResult,
|
|
hwPotsSelfCircuitTestRingVResult,
|
|
hwPotsSelfCircuitTestRingFResult,
|
|
hwPotsSelfCircuitTestVAGResult,
|
|
hwPotsSelfCircuitTestVBGResult,
|
|
hwPotsSelfCircuitTestFeedVValue,
|
|
hwPotsSelfCircuitTestRingVValue,
|
|
hwPotsSelfCircuitTestLoopCurrentValue,
|
|
hwPotsSelfCircuitTestLoopIfIndex ,
|
|
hwPotsSelfCircuitTestOnHookDetectResult ,
|
|
hwPotsSelfCircuitTestOffHookDetectResult ,
|
|
hwPotsSelfCircuitTestStopRingResult ,
|
|
hwPotsSelfCircuitTestVPoleResult ,
|
|
hwPotsSelfCircuitTestVBATLValue ,
|
|
hwPotsSelfCircuitTestVBATHValue ,
|
|
hwPotsSelfCircuitTestVBATRValue ,
|
|
hwPotsSelfCircuitTestRingFValue ,
|
|
hwPotsSelfCircuitTestVAGValue ,
|
|
hwPotsSelfCircuitTestVBGValue ,
|
|
hwPotsSelfCircuitTestVABPoleValue ,
|
|
hwPotsSelfCircuitTestABLCurrentValue ,
|
|
hwPotsSelfCircuitTestSLICTempValue
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Trap for the result of the PSTN circuit test:
|
|
1: hwPotsSelfCircuitTestLoopRequestID;
|
|
2: hwPotsSelfCircuitTestStatus;
|
|
3: hwPotsSelfCircuitTestVDDResult;
|
|
4: hwPotsSelfCircuitTestVBATLResult;
|
|
5: hwPotsSelfCircuitTestVBATHResult;
|
|
6: hwPotsSelfCircuitTestVBATRResult;
|
|
7: hwPotsSelfCircuitTestLoopCurrentResult;
|
|
8: hwPotsSelfCircuitTestFeedVResult;
|
|
9: hwPotsSelfCircuitTestRingVResult;
|
|
10: hwPotsSelfCircuitTestRingFResult;
|
|
11: hwPotsSelfCircuitTestVAGResult;
|
|
12: hwPotsSelfCircuitTestVBGResult;
|
|
13: hwPotsSelfCircuitTestFeedVValue;
|
|
14: hwPotsSelfCircuitTestRingVValue;
|
|
15: hwPotsSelfCircuitTestLoopCurrentValue;
|
|
16: hwPotsSelfCircuitTestLoopIfIndex;
|
|
17:hwPotsSelfCircuitTestOnHookDetectResult ;
|
|
18:hwPotsSelfCircuitTestOffHookDetectResult ;
|
|
19:hwPotsSelfCircuitTestStopRingResult ;
|
|
20:hwPotsSelfCircuitTestVPoleResult ;
|
|
21:hwPotsSelfCircuitTestVBATLValue ;
|
|
22:hwPotsSelfCircuitTestVBATHValue ;
|
|
23:hwPotsSelfCircuitTestVBATRValue ;
|
|
24:hwPotsSelfCircuitTestRingFValue ;
|
|
25:hwPotsSelfCircuitTestVAGValue ;
|
|
26:hwPotsSelfCircuitTestVBGValue ;
|
|
27:hwPotsSelfCircuitTestVABPoleValue ;
|
|
28:hwPotsSelfCircuitTestABLCurrentValue ;
|
|
29:hwPotsSelfCircuitTestSLICTempValue ;
|
|
"
|
|
::= { hwNTestGeneralTrapsOIDs 71 }
|
|
|
|
hwPstnCallEmulateOperatorTrap NOTIFICATION-TYPE
|
|
OBJECTS { hwPstnCallEmulateTestRequestID, hwPstnCallEmulateTestStatus, hwPstnCallEmulateTestResult, hwPstnCallEmulateIndex }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"PSTN call emulation test:
|
|
1: hwPstnCallEmulateTestRequestID;
|
|
2: Test status (Enumerated type. 1: No dial tone; 2: Dialup fails; 3: The called number does not match; 4: The called party does not take the phone off the hook; 5: Communication is normal; 6: Test fails);
|
|
3: Test result (Enumerated type. 1: No dial tone; 2: Caller not dialed; 3: Tel-num not matched; 4: Caller released;5: Test succeeds; 6: Call released;
|
|
7: Callee released; 8: Caller matching not completed; 9: Caller sending not completed; 10: Callee matching not completed; 11: Callee sending not completed; 12: Caller offHook busy;
|
|
13: Caller dialoging busy; 14: Caller match failed; 15: Callee match failed; 16: Caller port abnormal; 17: Callee port abnormal );
|
|
4: hwPstnCallEmulateIndex"
|
|
::= { hwNTestGeneralTrapsOIDs 72 }
|
|
|
|
hwISDNDiagnoseTestTrap NOTIFICATION-TYPE
|
|
OBJECTS { hwISDNDiagnoseTestRequestID, hwISDNDiagnoseTestResult, hwISDNDiagnoseTestCRCErrNum, hwISDNDiagnoseTestPortIndex }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This notification indicates that the trap for the result of the ISDN diagnose test:
|
|
1: hwISDNDiagnoseTestRequestID;
|
|
2: hwISDNDiagnoseTestResult;
|
|
3: hwISDNDiagnoseTestCRCErrNum;
|
|
4: hwISDNDiagnoseTestPortIndex"
|
|
::= { hwNTestGeneralTrapsOIDs 73 }
|
|
|
|
hwPstnLoopTestTrap NOTIFICATION-TYPE
|
|
OBJECTS { hwPstnLoopTestRequestID, hwPstnLoopTestResult, hwPstnLoopTestAssistIfIndex, hwPstnLoopTestSerialNo }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This notification indicates that the trap for the result of the PSTN loop test:
|
|
1: hwPstnLoopTestRequestID;
|
|
2: hwPstnLoopTestResult;
|
|
3: hwPstnLoopTestAssistIfIndex;
|
|
4: hwPstnLoopTestSerialNo"
|
|
::= { hwNTestGeneralTrapsOIDs 74 }
|
|
|
|
|
|
|
|
hwPstnCallTestOprTable OBJECT IDENTIFIER ::= { hwNTestMIBObjects 28 }
|
|
|
|
|
|
hwPstnCallTestSerialNo OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Serial number of the test"
|
|
::= { hwPstnCallTestOprTable 1 }
|
|
|
|
hwPstnCallTestCommand OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
start(1),
|
|
stop(2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Test command.
|
|
Options:
|
|
1. start(1) -start the test
|
|
2. stop(2) -stop the test
|
|
"
|
|
::= { hwPstnCallTestOprTable 2 }
|
|
|
|
hwPstnCallTestCmdType OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
fsp(1),
|
|
telno(2),
|
|
mgif(3),
|
|
v5if(4),
|
|
result(5)
|
|
}
|
|
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Specifying the test range.
|
|
Options:
|
|
1. fsp(1) -indicates By the shelf/slot/port
|
|
2. telno(2) -indicates By the telephone number
|
|
3. mgif(3) -indicates By the MG interface
|
|
4. v5if(4) -indicates By the V5 interface
|
|
5. result(5) -indicates Result of the last test
|
|
"
|
|
::= { hwPstnCallTestOprTable 3 }
|
|
|
|
hwPstnCallTestStartFsp OBJECT-TYPE
|
|
SYNTAX Integer32(0..65536)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Start shelf number/slot number/port number
|
|
Range:0-65536"
|
|
::= { hwPstnCallTestOprTable 4 }
|
|
|
|
hwPstnCallTestEndFsp OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"End shelf number/slot number/port number"
|
|
::= { hwPstnCallTestOprTable 5 }
|
|
|
|
hwPstnCallTestStartTelNo OBJECT-TYPE
|
|
SYNTAX OCTET STRING(SIZE(16))
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Start telephone number"
|
|
::= { hwPstnCallTestOprTable 6 }
|
|
|
|
hwPstnCallTestEndTelNo OBJECT-TYPE
|
|
SYNTAX OCTET STRING(SIZE(16))
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"End telephone number"
|
|
::= { hwPstnCallTestOprTable 7 }
|
|
|
|
hwPstnCallTestIfId OBJECT-TYPE
|
|
SYNTAX Integer32(0..7)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Interface ID
|
|
Range: 0-7"
|
|
::= { hwPstnCallTestOprTable 8 }
|
|
|
|
hwPstnCallTestDualCallFlag OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{dualcall(1),
|
|
notdualcall(2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Bi-directional call test flag.
|
|
Options:
|
|
1. dualcall(1) -indicates Start the bi-directional call
|
|
2. notdualcall(2) -indicates Disable the bi-directional call"
|
|
::= { hwPstnCallTestOprTable 9 }
|
|
|
|
hwPstnCallTestCalledTelNo OBJECT-TYPE
|
|
SYNTAX OCTET STRING(SIZE(16))
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Telephone number of the called party"
|
|
::= { hwPstnCallTestOprTable 10 }
|
|
|
|
hwPstnCallTestCallerId OBJECT-TYPE
|
|
SYNTAX Integer32(0..32767)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"ID of the subscriber under an interface. The subscriber under the MG interface uses the TID as its ID and the subscriber under the V5 interface uses the L3 address as its ID."
|
|
|
|
::= { hwPstnCallTestOprTable 11 }
|
|
|
|
hwPstnCallTestResultTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF HwPstnCallTestResultEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Table for the result of the query test
|
|
The index of this table is hwPstnCallTestResultIndex"
|
|
::= { hwNTestMIBObjects 29 }
|
|
|
|
|
|
|
|
hwPstnCallTestResultEntry OBJECT-TYPE
|
|
SYNTAX HwPstnCallTestResultEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Table for the result of the query test
|
|
The index of this entry is hwPstnCallTestResultIndex"
|
|
INDEX{
|
|
hwPstnCallTestResultIndex
|
|
}
|
|
::= { hwPstnCallTestResultTable 1 }
|
|
|
|
HwPstnCallTestResultEntry ::=
|
|
SEQUENCE {
|
|
hwPstnCallTestResultIndex Integer32,
|
|
hwPstnCallTestResultSerialNo Integer32,
|
|
hwPstnCallTestResultFrameid Integer32,
|
|
hwPstnCallTestResultSlotid Integer32,
|
|
hwPstnCallTestResultPortid Integer32,
|
|
hwPstnCallTestResult Integer32,
|
|
hwPstnCallTestResultIfId Integer32,
|
|
hwPstnCallTestResultCallerId Integer32,
|
|
hwPstnCallTestResultTelNo OCTET STRING
|
|
}
|
|
|
|
hwPstnCallTestResultIndex OBJECT-TYPE
|
|
SYNTAX Integer32(0..8000)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Index.
|
|
Range: 0-8000"
|
|
::= { hwPstnCallTestResultEntry 1 }
|
|
|
|
hwPstnCallTestResultSerialNo OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Serial number of the test"
|
|
::= { hwPstnCallTestResultEntry 2 }
|
|
|
|
hwPstnCallTestResultFrameid OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"ID of the shelf where the tested port is located"
|
|
::= { hwPstnCallTestResultEntry 3 }
|
|
|
|
hwPstnCallTestResultSlotid OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"ID of the slot where the tested port is located"
|
|
::= { hwPstnCallTestResultEntry 4 }
|
|
|
|
hwPstnCallTestResultPortid OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"ID of the tested port"
|
|
::= { hwPstnCallTestResultEntry 5 }
|
|
|
|
hwPstnCallTestResult OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Test result:
|
|
1. Normal
|
|
2. No dial tone
|
|
3. The called telephone does not ring
|
|
4. The voice circuit cannot get through
|
|
5. TSS is abnormal
|
|
6. The tested port is not correctly configured
|
|
7. The port is faulty
|
|
8. Skip the test
|
|
9. Other unknown cases"
|
|
::= { hwPstnCallTestResultEntry 6 }
|
|
|
|
hwPstnCallTestResultIfId OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Interface ID"
|
|
::= { hwPstnCallTestResultEntry 7 }
|
|
|
|
hwPstnCallTestResultCallerId OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Caller ID"
|
|
::= { hwPstnCallTestResultEntry 8 }
|
|
|
|
hwPstnCallTestResultTelNo OBJECT-TYPE
|
|
SYNTAX OCTET STRING(SIZE(16))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Telephone number of the tested port"
|
|
::= { hwPstnCallTestResultEntry 9 }
|
|
|
|
hw112UserInDialTestOprTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF Hw112UserInDialTestOprEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
This table is used to check whether a subscriber telephone can work in the normal state. The method is that the operator emulates a tested port to make calls.
|
|
The index of this table is ifIndex."
|
|
::= { hwNTestMIBObjects 30 }
|
|
|
|
hw112UserInDialTestOprEntry OBJECT-TYPE
|
|
SYNTAX Hw112UserInDialTestOprEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
This table is used to check whether a subscriber telephone can work in the normal state. The method is that the operator emulates a tested port to make calls.
|
|
The index of this entry is ifIndex."
|
|
|
|
INDEX {
|
|
ifIndex
|
|
}
|
|
::= { hw112UserInDialTestOprTable 1 }
|
|
|
|
Hw112UserInDialTestOprEntry ::=
|
|
SEQUENCE
|
|
{
|
|
hw112UserInDialTestOprType INTEGER,
|
|
hw112UserInDialTestTime Integer32,
|
|
hw112UserInDialTestResult INTEGER
|
|
}
|
|
|
|
hw112UserInDialTestOprType OBJECT-TYPE
|
|
SYNTAX INTEGER{stop(1),start(2)}
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Operation type.
|
|
Options:
|
|
1. stop(1) -stop the test
|
|
2. start(2) -start the test
|
|
The 112 protocol does not define the stop command."
|
|
::= { hw112UserInDialTestOprEntry 1 }
|
|
|
|
hw112UserInDialTestTime OBJECT-TYPE
|
|
SYNTAX Integer32(1..5)
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Test duration
|
|
Unit: second"
|
|
DEFVAL { 5 }
|
|
::= { hw112UserInDialTestOprEntry 2 }
|
|
|
|
hw112UserInDialTestResult OBJECT-TYPE
|
|
SYNTAX INTEGER{over(1)}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Operation result.
|
|
Options:
|
|
1. over(1) -indicates Success"
|
|
::= { hw112UserInDialTestOprEntry 3 }
|
|
|
|
hwISDNDiagnoseTestTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF HwISDNDiagnoseTestEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
User fault test table.
|
|
The index of this table is ifIndex.
|
|
"
|
|
::= { hwNTestMIBObjects 31 }
|
|
|
|
hwISDNDiagnoseTestEntry OBJECT-TYPE
|
|
SYNTAX HwISDNDiagnoseTestEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
User fault test table.
|
|
The index of this entry is ifIndex.
|
|
"
|
|
INDEX {
|
|
hwISDNDiagnoseTestPortIndex
|
|
}
|
|
::= { hwISDNDiagnoseTestTable 1 }
|
|
|
|
HwISDNDiagnoseTestEntry ::=
|
|
SEQUENCE
|
|
{
|
|
hwISDNDiagnoseTestPortIndex Integer32,
|
|
hwISDNDiagnoseTestOprType INTEGER,
|
|
hwISDNDiagnoseTestType INTEGER,
|
|
hwISDNDiagnoseTestItemType INTEGER,
|
|
hwISDNDiagnoseTestResult INTEGER,
|
|
hwISDNDiagnoseTestCRCErrNum Integer32,
|
|
hwISDNDiagnoseTestDeferredTestFlag INTEGER,
|
|
hwISDNDiagnoseTestDeferredTime Integer32,
|
|
hwISDNDiagnoseTestTimeoutProc INTEGER,
|
|
hwISDNDiagnoseTestCrcDetectPeriod Integer32,
|
|
hwISDNDiagnoseTestRequestID Integer32
|
|
}
|
|
|
|
hwISDNDiagnoseTestPortIndex OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
Port index
|
|
"
|
|
::= { hwISDNDiagnoseTestEntry 1 }
|
|
|
|
hwISDNDiagnoseTestOprType OBJECT-TYPE
|
|
SYNTAX INTEGER{start(1),stop(2)}
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
Test operation .
|
|
Options:
|
|
1. start(1) -indicates start the test
|
|
2. stop(2) -indicates stop the test
|
|
"
|
|
::= { hwISDNDiagnoseTestEntry 2 }
|
|
|
|
hwISDNDiagnoseTestType OBJECT-TYPE
|
|
SYNTAX INTEGER{routinetest(1),diagnosestest(2)}
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
Test type.
|
|
Options:
|
|
1. routinetest(1) -indicates routine test needs the port must be IS state, it only supports immediate test mode;
|
|
2. diagnosestest(2) -indicates diagnoses test needs the port must be OOS state, and Diagnose test supports deferred test mode.
|
|
"
|
|
::= { hwISDNDiagnoseTestEntry 3 }
|
|
|
|
hwISDNDiagnoseTestItemType OBJECT-TYPE
|
|
SYNTAX INTEGER{lineActiveTest(1),lineActiveAndCRCSendTest(2)}
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
Test item.
|
|
Options:
|
|
1. lineActiveTest(1) -indicates line active test
|
|
2. lineActiveAndCRCSendTest(2) -indicates line active test and CRC send test
|
|
"
|
|
::= { hwISDNDiagnoseTestEntry 4 }
|
|
|
|
hwISDNDiagnoseTestResult OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
activeok(1),
|
|
selfcheckfault(2),
|
|
loopback1operfault(3),
|
|
loopback1cancelfault(4),
|
|
loopback1crccheckfault(5),
|
|
activent1fault(6),
|
|
nt1crccheckfault(7),
|
|
ufaultloopback0succ(8),
|
|
loopback2operfault(9),
|
|
loopbackcancelfault(10),
|
|
loopback2crccheckfault(11),
|
|
noterminal(12),
|
|
timeout(13),
|
|
userstopsucc(14),
|
|
exceptstop(15),
|
|
nt1fault(16),
|
|
testcanceled(17)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
Test Result.
|
|
Options:
|
|
1. activeok(1) -indicates line active ok
|
|
2. selfcheckfault(2) -indicates board selfcheck fault
|
|
3. loopback1operfault(3) -indicates loopback1 operation fault
|
|
4. loopback1cancelfault(4) -indicates loopback1 cancel fault
|
|
5. loopback1crccheckfault(5) -indicates loopback1 crc check fault
|
|
6. activent1fault(6) -indicates active nt1 fault
|
|
7. nt1crccheckfault(7) -indicates nt1 crc check fault
|
|
8. ufaultloopback0succ(8) -indicates u fault loopback0 success
|
|
9. loopback2operfault(9) -indicates loopback2 operation fault
|
|
10. loopbackcancelfault(10) -indicates loopback2 cancel fault
|
|
11. loopback2crccheckfault(11) -indicates loopback2 crc check fault
|
|
12. noterminal(12) -indicates no terminal
|
|
13. timeout(13) -indicates time out
|
|
14. userstopsucc(14) -indicates user stop test success
|
|
15. exceptstop(15) -indicates except stop
|
|
16. nt1fault(16) -indicates nt1 fault
|
|
17. testcanceled(17) -indicates test is canceled;
|
|
"
|
|
::= { hwISDNDiagnoseTestEntry 5 }
|
|
|
|
hwISDNDiagnoseTestCRCErrNum OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
Indicates the CRC error's number.
|
|
"
|
|
::= { hwISDNDiagnoseTestEntry 6 }
|
|
|
|
hwISDNDiagnoseTestDeferredTestFlag OBJECT-TYPE
|
|
SYNTAX INTEGER{immediatetest(1),deferredtest(2)}
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
deferred test flag.
|
|
Options:
|
|
1. immediatetest(1) -indicates immediate test;
|
|
2. deferredtest(2) -indicates deferred test: Initiated when the port is in service. If the port is busy, the test operation
|
|
will be deferred. If the port changes to idle state before time out, the test will be executed
|
|
immediately. If the port keeps busy by the time out, the system will excecute a corresponding
|
|
operation according to what the user specified: canceling the test or forcing to test.
|
|
If the value of this leaf node is deferredtest(2), both hwISDNDiagnoseTestDeferredTime and
|
|
hwISDNDiagnoseTestTimeoutProc must be set. Only line diagnose test supports deferred test.
|
|
default test flag: immediatetest(1).
|
|
Default: immediatetest(1)
|
|
"
|
|
DEFVAL { 1 }
|
|
::= { hwISDNDiagnoseTestEntry 7 }
|
|
|
|
hwISDNDiagnoseTestDeferredTime OBJECT-TYPE
|
|
SYNTAX Integer32(1..1440)
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
Deferred time(Unit: minute):
|
|
this leaf node is valid only when the value of hwISDNDiagnoseTestDeferredTestFlag is deferredtest(2).
|
|
Range: 1-1440
|
|
Default: 30(minute)
|
|
"
|
|
DEFVAL { 30 }
|
|
::= { hwISDNDiagnoseTestEntry 8 }
|
|
|
|
hwISDNDiagnoseTestTimeoutProc OBJECT-TYPE
|
|
SYNTAX INTEGER{notest(1),test(2)}
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
timeout proc:
|
|
Options:
|
|
1. notest(1) -when deferred time out, if the port is still in service, line diagnose test will be canceled;
|
|
2. test(2) -when deferred time out, if the port is still in service, line diagnose test will be preformed by force.
|
|
this leaf node is valid only when the value of hwISDNDiagnoseTestDeferredTestFlag is deferredtest(2).
|
|
Default: notest(1).
|
|
"
|
|
DEFVAL { 1 }
|
|
::= { hwISDNDiagnoseTestEntry 9 }
|
|
|
|
hwISDNDiagnoseTestCrcDetectPeriod OBJECT-TYPE
|
|
SYNTAX Integer32(10..86400)
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
The CRC Check Period in Test.
|
|
Unit:second
|
|
Range:10-86400
|
|
"
|
|
DEFVAL { 10 }
|
|
|
|
::= { hwISDNDiagnoseTestEntry 10 }
|
|
|
|
hwISDNDiagnoseTestRequestID OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
Request ID
|
|
"
|
|
::= { hwISDNDiagnoseTestEntry 11 }
|
|
|
|
hwPstnCallEmulateOprTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF HwPstnCallEmulateOprEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
Operation table for the PSTN call emulation test (called party). It realizes the
|
|
function of the PSTN call emulation test (called party). This test helps check whether a subscriber port can
|
|
make calls normally as a called party.
|
|
The index of this table is hwPstnCallEmulateIndex"
|
|
::= { hwNTestMIBObjects 32 }
|
|
|
|
hwPstnCallEmulateOprEntry OBJECT-TYPE
|
|
SYNTAX HwPstnCallEmulateOprEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
Operation table for the PSTN call emulation test (called party). It realizes the
|
|
function of the PSTN call emulation test (called party). This test helps check whether a subscriber port can
|
|
make calls normally as a called party.
|
|
The index of this entry is hwPstnCallEmulateIndex"
|
|
INDEX {
|
|
hwPstnCallEmulateIndex
|
|
}
|
|
::= { hwPstnCallEmulateOprTable 1 }
|
|
|
|
|
|
HwPstnCallEmulateOprEntry ::=
|
|
SEQUENCE
|
|
{
|
|
hwPstnCallEmulateIndex Integer32,
|
|
hwPstnCallEmulateOprType INTEGER,
|
|
hwPstnCallEmulateCallerIfindex Integer32,
|
|
hwPstnCallEmulateCalledIfindex Integer32,
|
|
hwPstnCallEmulateCalledTelNo OCTET STRING,
|
|
hwPstnCallEmulateTestStatus INTEGER,
|
|
hwPstnCallEmulateTestResult INTEGER,
|
|
hwPstnCallEmulateTestCallerDTMFDetected OCTET STRING,
|
|
hwPstnCallEmulateTestCalleeDTMFDetected OCTET STRING,
|
|
hwPstnCallEmulateTestRequestID Integer32
|
|
}
|
|
|
|
hwPstnCallEmulateIndex OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Call emulation index"
|
|
::= { hwPstnCallEmulateOprEntry 1 }
|
|
|
|
|
|
hwPstnCallEmulateOprType OBJECT-TYPE
|
|
SYNTAX INTEGER{stop(1),start(2)}
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Operation type.
|
|
Options:
|
|
1. stop(1) -stop the test
|
|
2. start(2) -start the test"
|
|
::= { hwPstnCallEmulateOprEntry 2 }
|
|
|
|
hwPstnCallEmulateCallerIfindex OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Calling port of the call emulation test"
|
|
::= { hwPstnCallEmulateOprEntry 3 }
|
|
|
|
hwPstnCallEmulateCalledIfindex OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Called port of the call emulation test"
|
|
::= { hwPstnCallEmulateOprEntry 4 }
|
|
|
|
hwPstnCallEmulateCalledTelNo OBJECT-TYPE
|
|
SYNTAX OCTET STRING(SIZE(32))
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Called telephone number (max length: 32)"
|
|
::= { hwPstnCallEmulateOprEntry 5 }
|
|
|
|
hwPstnCallEmulateTestStatus OBJECT-TYPE
|
|
SYNTAX INTEGER{nodialtone(1), dialfailed(2), callednumbernotmatch(3), callednotpickupphone(4), testOK(5), testfailed(6)}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Test Status.
|
|
Options:
|
|
1. nodialtone(1) -indicates No dial tone
|
|
2. dialfailed(2) -indicates Dialup fails
|
|
3. callednumbernotmatch(3) -indicates The called number does not match
|
|
4. callednotpickupphone(4) -indicates The called party does not take the phone off the hook
|
|
5. testOK(5) -indicates Communication is normal
|
|
6. testfailed(6) -indicates Test fails
|
|
"
|
|
::= { hwPstnCallEmulateOprEntry 6 }
|
|
|
|
hwPstnCallEmulateTestResult OBJECT-TYPE
|
|
SYNTAX INTEGER{callerNoDialTone(1), callerNoDial(2), telNumNoMatch(3), callerRelease(4), testSucceed(5), callRelease(6), calledRelease(7), callerMatchNoCompleted(8), callerSendNoCompleted(9), calledMatchNoCompleted(10), calledSendNoCompleted(11), callerOffHookingBusy(12), callerDialogingBusy(13), callerMatchFailed(14), calledMatchFailed(15), callerPortAbnormal(16), calledPortAbnormal(17)}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Emulational Call Test Result
|
|
Options:
|
|
1. callerNoDialTone(1) -indicates the caller does not have dial tone
|
|
2. callerNoDial(2) -indicates the caller does not dial
|
|
3. telNumNoMatch(3) -indicates the telephone numbers are not matched
|
|
4. callerRelease(4) -indicates the caller release
|
|
5. testSucceed(5) -indicates the test succeed
|
|
6. callRelease(6) -indicates the call is released
|
|
7. calledRelease(7) -indicates the called is released
|
|
8. callerMatchNoCompleted(8) -indicates the caller's match is not completed
|
|
9. callerSendNoCompleted(9) -indicates the caller's sending is not completed
|
|
10.calledMatchNoCompleted(10) -indicates the called's match is not completed
|
|
11.calledSendNoCompleted(11) -indicates the called's sending is not completed
|
|
12.callerOffHookingBusy(12) -indicates the caller is busy in off-hooking
|
|
13.callerDialogingBusy(13) -indicates the caller is busy in dialogging
|
|
14.callerMatchFailed(14) -indicates the caller match failed
|
|
15.calledMatchFailed(15) -indicates the called match failed
|
|
16.callerPortAbnormal(16) -indicates the caller's port is abnormal
|
|
17.calledPortAbnormal(17) -indicates the called's port is abnormal
|
|
"
|
|
::= { hwPstnCallEmulateOprEntry 7 }
|
|
|
|
hwPstnCallEmulateTestCallerDTMFDetected OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(64))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Emulational Call Test Caller Detected Dtmf Num List"
|
|
::= { hwPstnCallEmulateOprEntry 8 }
|
|
|
|
hwPstnCallEmulateTestCalleeDTMFDetected OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(64))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Emulational Call Test Callee Detected Dtmf Num List"
|
|
::= { hwPstnCallEmulateOprEntry 9 }
|
|
|
|
hwPstnCallEmulateTestRequestID OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Request ID"
|
|
::= { hwPstnCallEmulateOprEntry 10 }
|
|
|
|
hwPstnLoopTestOprTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF HwPstnLoopTestOprEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
Loop test table
|
|
The index of this table is hwPstnLoopTestSerialNo"
|
|
::= { hwNTestMIBObjects 33 }
|
|
|
|
hwPstnLoopTestOprEntry OBJECT-TYPE
|
|
SYNTAX HwPstnLoopTestOprEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
Loop test table
|
|
The index of this entry is hwPstnLoopTestSerialNo"
|
|
|
|
INDEX {hwPstnLoopTestSerialNo}
|
|
::= { hwPstnLoopTestOprTable 1 }
|
|
|
|
HwPstnLoopTestOprEntry ::=
|
|
SEQUENCE
|
|
{
|
|
hwPstnLoopTestSerialNo Integer32,
|
|
hwPstnLoopTestDestIfIndex Integer32,
|
|
hwPstnLoopTestAssistIfIndex Integer32,
|
|
hwPstnLoopTestOprType INTEGER,
|
|
hwPstnLoopTestResult Integer32,
|
|
hwPstnLoopTestMode INTEGER,
|
|
hwPstnLoopTestDestTelNo OCTET STRING,
|
|
hwPstnLoopTestRequestID Integer32
|
|
}
|
|
|
|
hwPstnLoopTestSerialNo OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
Test serial number
|
|
"
|
|
|
|
::= { hwPstnLoopTestOprEntry 1 }
|
|
|
|
hwPstnLoopTestDestIfIndex OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
Target port ID"
|
|
|
|
::= { hwPstnLoopTestOprEntry 2 }
|
|
|
|
hwPstnLoopTestAssistIfIndex OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
Assistant port ID"
|
|
|
|
::= { hwPstnLoopTestOprEntry 3 }
|
|
|
|
hwPstnLoopTestOprType OBJECT-TYPE
|
|
SYNTAX INTEGER{start(1),stop(2)}
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
Operation type.
|
|
Options:
|
|
1. start(1) -indicates start the test
|
|
2. stop(2) -indicates stop the test
|
|
"
|
|
::= { hwPstnLoopTestOprEntry 4 }
|
|
|
|
hwPstnLoopTestResult OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
|
|
"
|
|
Test status:
|
|
1. Succeed; 2. Offhook on the target subscriber port fails; 3. Offhook on the assistant subscriber port fails; 4. Onhook on the target subscriber port fails; 5. Onhook on the assistant subscriber port fails;
|
|
6. Ringing on the target subscriber port fails; 7. Stopping ringing on the target subscriber port fails; 8. Channel test 1 fails. The target subscriber port transmits the DTMF signal to the TDM side. The assistant subscriber port does not detect any corresponding DTMF signal;
|
|
9. Channel test 2 fails. The assistant subscriber port transmits the DTMF signal to the TDM side. The target subscriber port does not detect any corresponding DTMF signal; 10. Channel test 3 fails. The target subscriber port transmits the DTMF signal to the IP side. The target subscriber port does not detect any corresponding DTMF signal on the TDM side; 11. Channel 4 test 4 fails. The assistant subscriber port transmits the DTMF signal to the IP side. The assistant subscriber port does not detect any corresponding DTMF signal on the TDM side;
|
|
12. Waiting for the dialing tone on the assistant subscriber port fails; 13. Waiting for the ringing on the target subscriber port fails; 14. The system fails due to abnormity; 15. The test stops because the tested subscriber port is busy;
|
|
16. The test stops because the user of the tested subscriber port hooks off; 17. The voice channel test fails because of insufficient DSP resources; 18. The DSP network function test fails (the turn around function is enabled); 19. The DSP network function test fails; 20. The codec loopback is successful, the SLIC loopback fails, and the SLIC chip is faulty; 21. The TDM loopback is successful, the codec loopback and SLIC loopback fail, and the codec chip, the SLIC chip, or the HighWay bus is faulty;
|
|
22. The DSP is faulty and the DSP TDM loopback fails; 23. The codec loopback fails and the codec chip is faulty.
|
|
"
|
|
|
|
|
|
::= { hwPstnLoopTestOprEntry 5 }
|
|
|
|
hwPstnLoopTestMode OBJECT-TYPE
|
|
SYNTAX INTEGER{hardwaretest(1),systemtest(2)}
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
Test mode
|
|
Options:
|
|
1. hardwaretest(1) -indicates it is a hardware test
|
|
2. systemtest(2) -indicates it is a systen test
|
|
"
|
|
::= { hwPstnLoopTestOprEntry 6 }
|
|
|
|
hwPstnLoopTestDestTelNo OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(16))
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
Telephone number of the target port (the maximum length is 16)
|
|
"
|
|
|
|
|
|
::= { hwPstnLoopTestOprEntry 7 }
|
|
|
|
hwPstnLoopTestRequestID OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
Request ID
|
|
"
|
|
|
|
::= { hwPstnLoopTestOprEntry 8 }
|
|
|
|
hwPstnCallEmulateConfigTable OBJECT IDENTIFIER ::= { hwNTestMIBObjects 34 }
|
|
|
|
hwPstnCallEmulateTestIndicationTone OBJECT-TYPE
|
|
SYNTAX INTEGER{enable(1),disable(2)}
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
The enable flag of playing the indication tone.
|
|
Options:
|
|
1. enable(1) -indicates that enable the indication tone
|
|
1. disable(2) -indicates that disable the indication tone
|
|
Default:disable(2)
|
|
"
|
|
::= { hwPstnCallEmulateConfigTable 1 }
|
|
|
|
hwPstnCallEmulateTestSendDTMF OBJECT-TYPE
|
|
SYNTAX INTEGER{enable(1),disable(2)}
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
Enable the function of sending DTMF numbers.
|
|
Options:
|
|
1. enable(1) -indicates that enable sending DTMF numbers
|
|
2. disable(2) -indicates that disable sending DTMF numbers
|
|
Default:enable(1)
|
|
"
|
|
::= { hwPstnCallEmulateConfigTable 2 }
|
|
|
|
hwPstnCallEmulateTestSendDTMFDelay OBJECT-TYPE
|
|
SYNTAX Integer32(1..60)
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
The delay between the time when the user starts testing and the time when the user sends the first DTMF number.
|
|
Default: 5
|
|
Unit: second
|
|
"
|
|
::= { hwPstnCallEmulateConfigTable 3 }
|
|
|
|
hwPstnCallEmulateTestSendDTMFPeriod OBJECT-TYPE
|
|
SYNTAX Integer32(200..8000)
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
The interval of sending DTMF numbers. It is used to set how often the system sends a DTMF number, in the unit of ms. It must be an integer multiple of 10.
|
|
Default: 1000
|
|
Unit: millisecond
|
|
"
|
|
::= { hwPstnCallEmulateConfigTable 4 }
|
|
|
|
hwPstnCallEmulateTestSendDTMFList OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(64))
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
The list of sending DTMF numbers.
|
|
Default: ****************
|
|
"
|
|
::= { hwPstnCallEmulateConfigTable 5 }
|
|
|
|
hwPstnCallEmulateTestDetectDTMF OBJECT-TYPE
|
|
SYNTAX INTEGER{enable(1),disable(2)}
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
Enable the function of detecting DTMF numbers.
|
|
Options:
|
|
1. enable(1) -indicates that enable the function of detecting DTMF numbers
|
|
2. disable(2) -indicates that disable the function of detecting DTMF numbers
|
|
Default:disable(2)
|
|
"
|
|
::= { hwPstnCallEmulateConfigTable 6 }
|
|
|
|
hwPstnCallEmulateTestMatchDTMF OBJECT-TYPE
|
|
SYNTAX INTEGER{enable(1),disable(2)}
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
Enable the function of matching DTMF numbers.
|
|
Options:
|
|
1. enable(1) -indicates that enable the function of matching DTMF numbers
|
|
2. disable(2) -indicates that disable the function of matching DTMF numbers
|
|
Default:disable(2)
|
|
"
|
|
::= { hwPstnCallEmulateConfigTable 7 }
|
|
|
|
hwPstnCallEmulateTestMatchDTMFList OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(64))
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
The list of matched DTMF numbers.
|
|
Default: *
|
|
"
|
|
::= { hwPstnCallEmulateConfigTable 8 }
|
|
|
|
hwPstnCallEmulateTestMatchDTMFResultTone OBJECT-TYPE
|
|
SYNTAX INTEGER{enable(1),disable(2)}
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
Enable flag of playing the result tone after DTMF number detection.
|
|
Options:
|
|
1. enable(1) -indicates that enable
|
|
2. disable(2) -indicates that disable
|
|
Default:disable(2)
|
|
"
|
|
::= { hwPstnCallEmulateConfigTable 9 }
|
|
|
|
hwPstnCallEmulateTestWaitTime OBJECT-TYPE
|
|
SYNTAX Integer32(5..600)
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
The time of call waiting in a called emulation test. The test is considered to be failed, if the system does not receive any call during this period.
|
|
Unit: second
|
|
Default: 600
|
|
"
|
|
::= { hwPstnCallEmulateConfigTable 10 }
|
|
|
|
hwPstnCallEmulateTestHoldTime OBJECT-TYPE
|
|
SYNTAX Integer32(5..600)
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
The time of call holding in an emulation test. The test is considered to be failed, if the system does not receive any call during this period.
|
|
Unit: second
|
|
Default: 600
|
|
"
|
|
::= { hwPstnCallEmulateConfigTable 11 }
|
|
|
|
hwLineTestParaTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF HwLineTestParaEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
pots test para config table
|
|
The index of this table is hwLineTestParaFrameIndex and hwLineTestParaSlotIndex"
|
|
::= { hwNTestMIBObjects 35 }
|
|
|
|
hwLineTestParaEntry OBJECT-TYPE
|
|
SYNTAX HwLineTestParaEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
pots test para config table
|
|
The index of this entry is hwLineTestParaFrameIndex and hwLineTestParaSlotIndex"
|
|
|
|
INDEX {hwLineTestParaFrameIndex,hwLineTestParaSlotIndex}
|
|
::= { hwLineTestParaTable 1 }
|
|
|
|
HwLineTestParaEntry ::=
|
|
SEQUENCE
|
|
{
|
|
hwLineTestParaOprType INTEGER,
|
|
hwLineTestParaFrameIndex Integer32,
|
|
hwLineTestParaSlotIndex Integer32,
|
|
hwLineTestParaPv Integer32,
|
|
hwLineTestParaAcF Integer32,
|
|
hwLineTestParaPitF Integer32,
|
|
hwLineTestParaMaxfeScv Integer32,
|
|
hwLineTestParaMinfeScv Integer32
|
|
}
|
|
|
|
hwLineTestParaOprType OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
configure(1),
|
|
restore(2),
|
|
invalid(-1)
|
|
}
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
The operation type of Test para config.
|
|
Options:
|
|
1. configure(1) -configure the value of physical layer test para
|
|
2. restore(2) -restore the value of physical layer test para
|
|
3. invalid(-1) -invalid value
|
|
"
|
|
::= { hwLineTestParaEntry 1 }
|
|
|
|
hwLineTestParaFrameIndex OBJECT-TYPE
|
|
SYNTAX Integer32 (-1 | 0..255)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates the frameID of configuring test para.
|
|
Range: 0-255|-1
|
|
"
|
|
::= { hwLineTestParaEntry 2 }
|
|
|
|
hwLineTestParaSlotIndex OBJECT-TYPE
|
|
SYNTAX Integer32 (-1 | 0..255)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates the slotID of configuring test para.
|
|
Range: 0-255|-1
|
|
"
|
|
::= { hwLineTestParaEntry 3 }
|
|
|
|
hwLineTestParaPv OBJECT-TYPE
|
|
SYNTAX Integer32 (-1 | 0..100000)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates the peak line test voltage of permitted sending.
|
|
Range: 0-100000|-1
|
|
Default: 50000
|
|
Unit: mV
|
|
"
|
|
DEFVAL { 50000 }
|
|
::= { hwLineTestParaEntry 4 }
|
|
|
|
hwLineTestParaAcF OBJECT-TYPE
|
|
SYNTAX Integer32 (-1 | 10..1000)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates the AC signal frequency when testing the capacitance and catheter.
|
|
Range: 10-1000|-1
|
|
Default: 25
|
|
Unit: Hz
|
|
"
|
|
DEFVAL { 25 }
|
|
::= { hwLineTestParaEntry 5 }
|
|
|
|
hwLineTestParaPitF OBJECT-TYPE
|
|
SYNTAX Integer32 (-1 | 300..3400)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates the frequency of line test voice.
|
|
Range: 300-3400|-1
|
|
Default: 800
|
|
Unit: Hz
|
|
"
|
|
DEFVAL { 800 }
|
|
::= { hwLineTestParaEntry 6 }
|
|
|
|
hwLineTestParaMaxfeScv OBJECT-TYPE
|
|
SYNTAX Integer32 (-1 | 0..50000)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates the max voltage of Signature test.
|
|
Range: 0-50000|-1
|
|
Default: 50000
|
|
Unit: mV
|
|
Step: 1000
|
|
"
|
|
DEFVAL { 50000 }
|
|
::= { hwLineTestParaEntry 7 }
|
|
|
|
hwLineTestParaMinfeScv OBJECT-TYPE
|
|
SYNTAX Integer32 (-1 | 0..50000)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates the min voltage of Signature test.
|
|
Range: 0-50000|-1
|
|
Default: 3000
|
|
Unit: mV
|
|
Step: 1000
|
|
"
|
|
DEFVAL { 3000 }
|
|
::= { hwLineTestParaEntry 8 }
|
|
|
|
hwMonitorTestOprTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF HwMonitorTestOprEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
monitor test table
|
|
The index of this table is ifIndex"
|
|
::= { hwNTestMIBObjects 36 }
|
|
|
|
hwMonitorTestOprEntry OBJECT-TYPE
|
|
SYNTAX HwMonitorTestOprEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
monitor test table
|
|
The index of this entry is ifIndex"
|
|
|
|
INDEX {
|
|
ifIndex
|
|
}
|
|
::= { hwMonitorTestOprTable 1 }
|
|
|
|
HwMonitorTestOprEntry ::=
|
|
SEQUENCE
|
|
{
|
|
hwMonitorTestAGV Integer32,
|
|
hwMonitorTestBGV Integer32,
|
|
hwMonitorTestLongitudinalCurrent Integer32,
|
|
hwMonitorTestTransversalCurrent Integer32,
|
|
hwMonitorTestBatteryVoltage Integer32,
|
|
hwMonitorTestSLICTemperature Integer32
|
|
}
|
|
|
|
hwMonitorTestAGV OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
Monitor test A->ground voltage.
|
|
Unit: millivolt, mV
|
|
"
|
|
::= { hwMonitorTestOprEntry 1 }
|
|
|
|
hwMonitorTestBGV OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
Monitor test B->ground voltage.
|
|
Unit: millivolt, mV
|
|
"
|
|
::= { hwMonitorTestOprEntry 2 }
|
|
|
|
hwMonitorTestLongitudinalCurrent OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
Monitor test Longitudinal Current.
|
|
Unit: uA
|
|
"
|
|
::= { hwMonitorTestOprEntry 3 }
|
|
|
|
hwMonitorTestTransversalCurrent OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
Monitor test Transversal Current.
|
|
Unit: uA
|
|
"
|
|
::= { hwMonitorTestOprEntry 4 }
|
|
|
|
hwMonitorTestBatteryVoltage OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
Monitor test Battery Voltage.
|
|
Unit: millivolt, mV
|
|
"
|
|
::= { hwMonitorTestOprEntry 5 }
|
|
|
|
hwMonitorTestSLICTemperature OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
Monitor test SLIC Temperature.
|
|
Unit: oC
|
|
"
|
|
::= { hwMonitorTestOprEntry 6 }
|
|
|
|