998 lines
34 KiB
Plaintext
998 lines
34 KiB
Plaintext
-- =================================================================
|
|
-- Copyright (C) 2020 by HUAWEI TECHNOLOGIES. All rights reserved.
|
|
--
|
|
-- Description: Huawei Ethernet ND MIB
|
|
-- Reference: HUAWEI Enterprise MIB
|
|
-- Version: V1.16
|
|
-- History:
|
|
-- gaoning , 2014-06-27, add nodes for ND.
|
|
-- =================================================================
|
|
|
|
HUAWEI-ND-MIB DEFINITIONS ::= BEGIN
|
|
|
|
IMPORTS
|
|
hwDatacomm
|
|
FROM HUAWEI-MIB
|
|
OBJECT-TYPE, MODULE-IDENTITY, OBJECT-TYPE, IpAddress, Counter32, Integer32, Unsigned32, NOTIFICATION-TYPE
|
|
FROM SNMPv2-SMI
|
|
PhysAddress, DisplayString, RowStatus
|
|
FROM SNMPv2-TC
|
|
NOTIFICATION-GROUP, OBJECT-GROUP, MODULE-COMPLIANCE
|
|
FROM SNMPv2-CONF
|
|
ifIndex, ifName, InterfaceIndex,InterfaceIndexOrZero,ifAdminStatus,ifOperStatus,ifDescr
|
|
FROM IF-MIB
|
|
Ipv6Address
|
|
FROM IPV6-TC
|
|
PhysicalIndex, entPhysicalIndex, entPhysicalName
|
|
FROM ENTITY-MIB;
|
|
|
|
hwNDMIB MODULE-IDENTITY
|
|
LAST-UPDATED "202011191449Z"
|
|
ORGANIZATION
|
|
"Huawei Technologies Co.,Ltd."
|
|
CONTACT-INFO
|
|
"Huawei Industrial Base
|
|
Bantian, Longgang
|
|
Shenzhen 518129
|
|
People's Republic of China
|
|
Website: http://www.huawei.com
|
|
Email: support@huawei.com
|
|
"
|
|
|
|
DESCRIPTION
|
|
"V1.16, Add enum of hwNDLimitSuppressType at 2020-11-19."
|
|
|
|
REVISION "202011191449Z"
|
|
DESCRIPTION
|
|
"V1.15, Modify description of hwNDProxyDynThresholdExceedAlarm and hwNDProxyDynThresholdResumeAlarm at 2020-10-15"
|
|
|
|
REVISION "202010151512Z"
|
|
DESCRIPTION
|
|
"V1.14, Modify description of hwNDProxyThresholdExceedAlarm and hwNDProxyThresholdResumeAlarm at 2020-10-15"
|
|
|
|
REVISION "202010150936Z"
|
|
DESCRIPTION
|
|
"V1.13, Modify description of hwSlotProxyNDThresholdExceedAlarm and hwSlotProxyNDThresholdResumeAlarm at 2020-09-29"
|
|
|
|
REVISION "202009291600Z"
|
|
DESCRIPTION
|
|
"V1.12, modify English low-level mistakes."
|
|
REVISION "202008101643Z"
|
|
DESCRIPTION
|
|
"V1.11, modify the element description of HwNDRateEntryLimit."
|
|
REVISION "202005282000Z"
|
|
DESCRIPTION
|
|
"V1.10, modify the element type of HwNDRateEntryLimit."
|
|
REVISION "202004231000Z"
|
|
DESCRIPTION
|
|
"V1.09, add hwNDAntiAttackRateLimit."
|
|
REVISION "202003061000Z"
|
|
DESCRIPTION
|
|
"V1.08, add hwNDDADNotFinished."
|
|
REVISION "201907181600Z"
|
|
DESCRIPTION
|
|
"V1.07, MOD hwNDDulicateTgtIf, hwNDDulicateLocalIf OBJECT-TYPE."
|
|
REVISION "201906051426Z"
|
|
DESCRIPTION
|
|
"V1.06, add hwNDDuplicateIPv6, hwNDDuplicateIPv6Resume."
|
|
REVISION "201905271426Z"
|
|
DESCRIPTION
|
|
"V1.06, add hwNDDuplicateIPv6, hwNDDuplicateIPv6Resume."
|
|
REVISION "201905251426Z"
|
|
DESCRIPTION "V1.05, add hwNDSlotRemoteNumber and hwNDIntfRemoteNumber."
|
|
REVISION "201802081600Z"
|
|
DESCRIPTION "V1.04, add hwNDHostConflict and hwNDHostConflictResolved."
|
|
REVISION "201708171600Z"
|
|
DESCRIPTION "V1.02, Modify description of hwNDSlotThresholdExceedValue and hwNDIntfThresholdExceedValue at 2017-07-04"
|
|
|
|
REVISION "201707041600Z"
|
|
DESCRIPTION "V1.02, Modify description of hwSlotNDThresholdExceedAlarm at 2017-07-04."
|
|
|
|
|
|
REVISION "201407011600Z"
|
|
DESCRIPTION "V1.01, initial version."
|
|
|
|
REVISION "201008111600Z"
|
|
DESCRIPTION "V1.00, initial version."
|
|
|
|
::= { hwDatacomm 332 }
|
|
|
|
hwNDObjects OBJECT IDENTIFIER ::= { hwNDMIB 1 }
|
|
|
|
-- =================================================================
|
|
-- 1th slot nd entries alarm
|
|
-- =================================================================
|
|
hwNDStatisticsPerSlotTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF HwNDStatisticsPerSlotEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates the threshold of the alarm generated in slot."
|
|
::= { hwNDObjects 1 }
|
|
|
|
hwNDStatisticsPerSlotEntry OBJECT-TYPE
|
|
SYNTAX HwNDStatisticsPerSlotEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates the threshold of the alarm generated in slot."
|
|
INDEX {hwNDSlotPhysicalIndex}
|
|
::= { hwNDStatisticsPerSlotTable 1 }
|
|
|
|
HwNDStatisticsPerSlotEntry ::=
|
|
SEQUENCE {
|
|
hwNDSlotPhysicalIndex Unsigned32 ,
|
|
hwNDSlotThresholdExceedValue Unsigned32 ,
|
|
hwNDSlotThresholdResumeValue Unsigned32 ,
|
|
hwNDSlotDynamicNumber Unsigned32 ,
|
|
hwNDSlotStaticNumber Unsigned32 ,
|
|
hwNDSlotTotalNumber Unsigned32 ,
|
|
hwNDSlotRemoteNumber Unsigned32
|
|
}
|
|
|
|
hwNDSlotPhysicalIndex OBJECT-TYPE
|
|
SYNTAX Unsigned32(0..4294967294)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The slot of alarm generated."
|
|
::= { hwNDStatisticsPerSlotEntry 1 }
|
|
|
|
hwNDSlotThresholdExceedValue OBJECT-TYPE
|
|
SYNTAX Unsigned32(1..100)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates an ND entry alarm threshold on a board. An ND entry threshold-exceeding alarm is generated when the ratio of the number of ND entries on a board to the maximum number allowed is greater than or equal to the alarm threshold."
|
|
::= { hwNDStatisticsPerSlotEntry 2 }
|
|
|
|
hwNDSlotThresholdResumeValue OBJECT-TYPE
|
|
SYNTAX Unsigned32(1..100)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates an ND entry clear alarm threshold on a board. An ND entry clear alarm is generated when the ratio of the number of ND entries on a board to the maximum number allowed is less than or equal to the clear alarm threshold."
|
|
::= { hwNDStatisticsPerSlotEntry 3 }
|
|
|
|
hwNDSlotDynamicNumber OBJECT-TYPE
|
|
SYNTAX Unsigned32(0..4294967294)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Current dynamic ND entries in slot."
|
|
::= { hwNDStatisticsPerSlotEntry 4 }
|
|
|
|
hwNDSlotStaticNumber OBJECT-TYPE
|
|
SYNTAX Unsigned32(0..4294967294)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Current static ND entries in slot."
|
|
::= { hwNDStatisticsPerSlotEntry 5 }
|
|
|
|
hwNDSlotTotalNumber OBJECT-TYPE
|
|
SYNTAX Unsigned32(0..4294967294)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Maximum ND entries number for slot."
|
|
::= { hwNDStatisticsPerSlotEntry 6 }
|
|
|
|
hwNDSlotRemoteNumber OBJECT-TYPE
|
|
SYNTAX Unsigned32(0..4294967294)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Current remote ND entries in slot."
|
|
::= { hwNDStatisticsPerSlotEntry 7 }
|
|
|
|
-- =================================================================
|
|
-- 2th interface nd entries alarm
|
|
-- =================================================================
|
|
hwNDStatisticsPerIfTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF HwNDStatisticsPerIfEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates the threshold of the alarm generated in interface."
|
|
::= { hwNDObjects 2 }
|
|
|
|
hwNDStatisticsPerIfEntry OBJECT-TYPE
|
|
SYNTAX HwNDStatisticsPerIfEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates the threshold of the alarm generated in interface."
|
|
INDEX {hwNDIntfIndex}
|
|
::= { hwNDStatisticsPerIfTable 1 }
|
|
|
|
HwNDStatisticsPerIfEntry ::=
|
|
SEQUENCE {
|
|
hwNDIntfIndex Unsigned32 ,
|
|
hwNDIntfThresholdExceedValue Unsigned32 ,
|
|
hwNDIntfThresholdResumeValue Unsigned32 ,
|
|
hwNDIntfDynamicNumber Unsigned32 ,
|
|
hwNDIntfStaticNumber Unsigned32 ,
|
|
hwNDIntfTotalNumber Unsigned32 ,
|
|
hwNDIntfRemoteNumber Unsigned32
|
|
}
|
|
|
|
hwNDIntfIndex OBJECT-TYPE
|
|
SYNTAX Unsigned32(0..4294967294)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The interface of alarm generated."
|
|
::= { hwNDStatisticsPerIfEntry 1 }
|
|
|
|
hwNDIntfThresholdExceedValue OBJECT-TYPE
|
|
SYNTAX Unsigned32(1..100)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates an ND entry alarm threshold on an interface. An ND entry threshold-exceeding alarm is generated when the ratio of the number of ND entries on an interface to the maximum number allowed is greater than or equal to the alarm threshold."
|
|
::= { hwNDStatisticsPerIfEntry 2 }
|
|
|
|
hwNDIntfThresholdResumeValue OBJECT-TYPE
|
|
SYNTAX Unsigned32(1..100)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates an ND entry clear alarm threshold on an interface. An ND entry clear alarm is generated when the ratio of the number of ND entries on an interface to the maximum number allowed is less than or equal to the clear alarm threshold."
|
|
::= { hwNDStatisticsPerIfEntry 3 }
|
|
|
|
hwNDIntfDynamicNumber OBJECT-TYPE
|
|
SYNTAX Unsigned32(0..4294967294)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Current dynamic ND entries in interface."
|
|
::= { hwNDStatisticsPerIfEntry 4 }
|
|
|
|
hwNDIntfStaticNumber OBJECT-TYPE
|
|
SYNTAX Unsigned32(0..4294967294)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Current static ND entries in interface."
|
|
::= { hwNDStatisticsPerIfEntry 5 }
|
|
|
|
hwNDIntfTotalNumber OBJECT-TYPE
|
|
SYNTAX Unsigned32(0..4294967294)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Maximum ND entries number for interface."
|
|
::= { hwNDStatisticsPerIfEntry 6 }
|
|
|
|
hwNDIntfRemoteNumber OBJECT-TYPE
|
|
SYNTAX Unsigned32(0..4294967294)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Current remote ND entries in interface."
|
|
::= { hwNDStatisticsPerIfEntry 7 }
|
|
|
|
-- =================================================================
|
|
-- 3th ND host IP address conflicted
|
|
-- =================================================================
|
|
hwNDHostInfoTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF HwNDHostInfoEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The table contains the information of local host and remote host.
|
|
The information includes host IP, host MAC, gateway VtepIP, gateway MAC."
|
|
::= { hwNDObjects 3 }
|
|
|
|
hwNDHostInfoEntry OBJECT-TYPE
|
|
SYNTAX HwNDHostInfoEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Entries of the host information table."
|
|
INDEX {hwNDHostBdId, hwNDHostIpv6Addr}
|
|
::= { hwNDHostInfoTable 1 }
|
|
|
|
HwNDHostInfoEntry ::=
|
|
SEQUENCE {
|
|
hwNDHostBdId Unsigned32 ,
|
|
hwNDHostIpv6Addr Ipv6Address ,
|
|
hwNDHostLocalMAC PhysAddress ,
|
|
hwNDHostLocalIf OCTET STRING ,
|
|
hwNDHostLocalPevid Unsigned32 ,
|
|
hwNDHostLocalCevid Unsigned32 ,
|
|
hwNDHostRemoteMAC PhysAddress ,
|
|
hwNDHostRemoteIf OCTET STRING ,
|
|
hwNDHostRemotePevid Unsigned32 ,
|
|
hwNDHostRemoteCevid Unsigned32
|
|
}
|
|
|
|
hwNDHostBdId OBJECT-TYPE
|
|
SYNTAX Unsigned32(0..4294967294)
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The bridge domain ID of alarm generated."
|
|
::= { hwNDHostInfoEntry 1 }
|
|
|
|
hwNDHostIpv6Addr OBJECT-TYPE
|
|
SYNTAX Ipv6Address
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The IPv6 address of alarm generated in BD."
|
|
::= { hwNDHostInfoEntry 2 }
|
|
|
|
hwNDHostLocalMAC OBJECT-TYPE
|
|
SYNTAX PhysAddress
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The MAC address of hwNDHostIpv6Addr."
|
|
::= { hwNDHostInfoEntry 3 }
|
|
|
|
hwNDHostLocalIf OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The interface of BD that generate alarm."
|
|
::= { hwNDHostInfoEntry 4 }
|
|
|
|
hwNDHostLocalPevid OBJECT-TYPE
|
|
SYNTAX Unsigned32(0..4094)
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The pevid of hwNDHostWorkIfIndex."
|
|
::= { hwNDHostInfoEntry 5 }
|
|
|
|
hwNDHostLocalCevid OBJECT-TYPE
|
|
SYNTAX Unsigned32(0..4094)
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The cevid of hwNDHostWorkIfIndex."
|
|
::= { hwNDHostInfoEntry 6 }
|
|
|
|
hwNDHostRemoteMAC OBJECT-TYPE
|
|
SYNTAX PhysAddress
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The MAC address of hwNDHostIpv6Addr."
|
|
::= { hwNDHostInfoEntry 7 }
|
|
|
|
hwNDHostRemoteIf OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The interface of BD that generate alarm."
|
|
::= { hwNDHostInfoEntry 8 }
|
|
|
|
hwNDHostRemotePevid OBJECT-TYPE
|
|
SYNTAX Unsigned32(0..4094)
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The pevid of hwNDHostWorkIfIndex."
|
|
::= { hwNDHostInfoEntry 9 }
|
|
|
|
hwNDHostRemoteCevid OBJECT-TYPE
|
|
SYNTAX Unsigned32(0..4094)
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The cevid of hwNDHostWorkIfIndex."
|
|
::= { hwNDHostInfoEntry 10 }
|
|
|
|
|
|
-- =================================================================
|
|
-- ND Dupicate IPv6 address
|
|
-- =================================================================
|
|
hwNDDuplicateIPv6InfoTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF HwNDDuplicateIPv6InfoEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The table contains the information of duplicate ipv6 address and interface.
|
|
The information includes PktType,TgtIpv6Address,TgtInterfaceName,LocInterfaceName,SrcMacAddress,DstMacAddress,SrcIpv6Address,DstIpv6Address,PeVLAN,CeVLAN,SelfLoop and DadAttempts."
|
|
::= { hwNDObjects 4 }
|
|
|
|
hwNDDuplicateIPv6InfoEntry OBJECT-TYPE
|
|
SYNTAX HwNDDuplicateIPv6InfoEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Entries of the Dupicate IPv6 table."
|
|
INDEX {hwNDDulicatePktType, hwNDDulicateTgtIPv6Addr, hwNDDulicateTgtIf}
|
|
::= { hwNDDuplicateIPv6InfoTable 1 }
|
|
|
|
HwNDDuplicateIPv6InfoEntry ::=
|
|
SEQUENCE {
|
|
hwNDDulicatePktType OCTET STRING ,
|
|
hwNDDulicateTgtIPv6Addr Ipv6Address ,
|
|
hwNDDulicateTgtIf DisplayString,
|
|
hwNDDulicateLocalIf DisplayString,
|
|
hwNDDulicateSrcMAC PhysAddress ,
|
|
hwNDDulicateDstMAC PhysAddress ,
|
|
hwNDDulicateSrcIPv6Addr Ipv6Address ,
|
|
hwNDDulicateDstIPv6Addr Ipv6Address ,
|
|
hwNDDulicatePeVLAN Unsigned32 ,
|
|
hwNDDulicateCeVLAN Unsigned32 ,
|
|
hwNDDulicateSelfLoop OCTET STRING ,
|
|
hwNDDulicateDadAttempts Unsigned32
|
|
}
|
|
|
|
hwNDDulicatePktType OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (0..255))
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The packet type in the received ND message."
|
|
::= { hwNDDuplicateIPv6InfoEntry 1 }
|
|
|
|
hwNDDulicateTgtIPv6Addr OBJECT-TYPE
|
|
SYNTAX Ipv6Address
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The IPv6 address of alarm generated."
|
|
::= { hwNDDuplicateIPv6InfoEntry 2 }
|
|
|
|
hwNDDulicateTgtIf OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..255))
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The interface name receiving the alarm."
|
|
::= { hwNDDuplicateIPv6InfoEntry 3 }
|
|
|
|
hwNDDulicateLocalIf OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..255))
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The local interface name receiving the alarm."
|
|
::= { hwNDDuplicateIPv6InfoEntry 4 }
|
|
|
|
hwNDDulicateSrcMAC OBJECT-TYPE
|
|
SYNTAX PhysAddress
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The source MAC address in the received ND message."
|
|
::= { hwNDDuplicateIPv6InfoEntry 5 }
|
|
|
|
hwNDDulicateDstMAC OBJECT-TYPE
|
|
SYNTAX PhysAddress
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The destination MAC address in the received ND message."
|
|
::= { hwNDDuplicateIPv6InfoEntry 6 }
|
|
|
|
hwNDDulicateSrcIPv6Addr OBJECT-TYPE
|
|
SYNTAX Ipv6Address
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The source IPv6 address in the received ND message."
|
|
::= { hwNDDuplicateIPv6InfoEntry 7 }
|
|
|
|
hwNDDulicateDstIPv6Addr OBJECT-TYPE
|
|
SYNTAX Ipv6Address
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The destination IPv6 address in the received ND message."
|
|
::= { hwNDDuplicateIPv6InfoEntry 8 }
|
|
|
|
hwNDDulicatePeVLAN OBJECT-TYPE
|
|
SYNTAX Unsigned32(0..4094)
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The outer VLAN ID carried in the received ND message."
|
|
::= { hwNDDuplicateIPv6InfoEntry 9 }
|
|
|
|
hwNDDulicateCeVLAN OBJECT-TYPE
|
|
SYNTAX Unsigned32(0..4094)
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The inner VLAN ID carried in the received ND message."
|
|
::= { hwNDDuplicateIPv6InfoEntry 10 }
|
|
|
|
hwNDDulicateSelfLoop OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (0..255))
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The self-loop flag in the received ND message."
|
|
::= { hwNDDuplicateIPv6InfoEntry 11 }
|
|
|
|
hwNDDulicateDadAttempts OBJECT-TYPE
|
|
SYNTAX Unsigned32(0..4294967294)
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The attempted times in the received message."
|
|
::= { hwNDDuplicateIPv6InfoEntry 12 }
|
|
|
|
-- =================================================================
|
|
-- 5th ND DAD Not Finished
|
|
-- =================================================================
|
|
hwNDDADInfoTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF HwNDDADInfoEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The table contains the information of DAD."
|
|
::= { hwNDObjects 5 }
|
|
|
|
hwNDDADInfoEntry OBJECT-TYPE
|
|
SYNTAX HwNDDADInfoEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Entries of the host information table."
|
|
INDEX {hwNDDADIf, hwNDDADAddr}
|
|
::= { hwNDDADInfoTable 1 }
|
|
|
|
HwNDDADInfoEntry ::=
|
|
SEQUENCE {
|
|
hwNDDADIf OCTET STRING ,
|
|
hwNDDADAddr Ipv6Address ,
|
|
hwNDDADTimeout Unsigned32
|
|
}
|
|
|
|
hwNDDADIf OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The interface of DAD."
|
|
::= { hwNDDADInfoEntry 1 }
|
|
|
|
hwNDDADAddr OBJECT-TYPE
|
|
SYNTAX Ipv6Address
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The IPv6 address of DAD."
|
|
::= { hwNDDADInfoEntry 2 }
|
|
|
|
hwNDDADTimeout OBJECT-TYPE
|
|
SYNTAX Unsigned32(1..60)
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The timeout of DAD."
|
|
::= { hwNDDADInfoEntry 3 }
|
|
|
|
-- =================================================================
|
|
-- 6th ND Anti-attack Rate Limit
|
|
-- =================================================================
|
|
hwNDRateLimitTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF HwNDRateLimitEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The table contains the information of rate limit."
|
|
::= { hwNDObjects 6 }
|
|
|
|
hwNDRateLimitEntry OBJECT-TYPE
|
|
SYNTAX HwNDRateLimitEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Entries of the rate limit table."
|
|
INDEX {hwNDLimitPacketType}
|
|
::= { hwNDRateLimitTable 1 }
|
|
|
|
HwNDRateLimitEntry ::=
|
|
SEQUENCE {
|
|
hwNDLimitPacketType INTEGER ,
|
|
hwNDLimitSuppressVal Unsigned32 ,
|
|
hwNDLimitCurrentVal Unsigned32 ,
|
|
hwNDLimitSuppressType INTEGER ,
|
|
hwNDLimitIf OCTET STRING ,
|
|
hwNDLimitWorkIf OCTET STRING ,
|
|
hwNDLimitSrcMAC PhysAddress ,
|
|
hwNDLimitDstMAC PhysAddress ,
|
|
hwNDLimitSrcIP Ipv6Address ,
|
|
hwNDLimitDstIP Ipv6Address ,
|
|
hwNDLimitTargetIP Ipv6Address ,
|
|
hwNDLimitPeVLAN Unsigned32 ,
|
|
hwNDLimitCeVLAN Unsigned32
|
|
}
|
|
|
|
hwNDLimitPacketType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
rs(1), -- router solicitation packet
|
|
ra(2), -- router advertisement packet
|
|
ns(3), -- neighbor solicitation packet
|
|
na(4), -- neighbor advertisement packet
|
|
ndmiss(5) -- neighbor discovery miss
|
|
}
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Type of packets that are suppressed."
|
|
::= { hwNDRateLimitEntry 1 }
|
|
|
|
hwNDLimitSuppressVal OBJECT-TYPE
|
|
SYNTAX Unsigned32(0..5000)
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Rate limit of ND packets or ND Miss messages."
|
|
::= { hwNDRateLimitEntry 2 }
|
|
|
|
hwNDLimitCurrentVal OBJECT-TYPE
|
|
SYNTAX Unsigned32(0..4294967294)
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Current rate of ND packets or ND Miss messages."
|
|
::= { hwNDRateLimitEntry 3 }
|
|
|
|
hwNDLimitSuppressType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
srcip(1), -- source ip
|
|
srcmac(2), -- source mac
|
|
interface(3), -- interface
|
|
interfacesrcip(4), -- interface source ip
|
|
vsglobal(5), -- virtual system
|
|
lsglobal(6), -- logic system
|
|
dstip(7), -- destination ip
|
|
tgtip(8) -- target ip
|
|
}
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Suppress type."
|
|
::= { hwNDRateLimitEntry 4 }
|
|
|
|
hwNDLimitIf OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Interface name."
|
|
::= { hwNDRateLimitEntry 5 }
|
|
|
|
hwNDLimitWorkIf OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Work interface name."
|
|
::= { hwNDRateLimitEntry 6 }
|
|
|
|
hwNDLimitSrcMAC OBJECT-TYPE
|
|
SYNTAX PhysAddress
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Source MAC address, if the address is an all-zero address, it is invalid."
|
|
::= { hwNDRateLimitEntry 7 }
|
|
|
|
hwNDLimitDstMAC OBJECT-TYPE
|
|
SYNTAX PhysAddress
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Destination MAC address, if the address is an all-zero address, it is invalid."
|
|
::= { hwNDRateLimitEntry 8 }
|
|
|
|
hwNDLimitSrcIP OBJECT-TYPE
|
|
SYNTAX Ipv6Address
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Source IPv6 address, when the packet type is not NS or RS, the source address is invalid if it is an unspecified address."
|
|
::= { hwNDRateLimitEntry 9 }
|
|
|
|
hwNDLimitDstIP OBJECT-TYPE
|
|
SYNTAX Ipv6Address
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Destination IPv6 address, if the address is an unspecified address, it is invalid."
|
|
::= { hwNDRateLimitEntry 10 }
|
|
|
|
hwNDLimitTargetIP OBJECT-TYPE
|
|
SYNTAX Ipv6Address
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Target IPv6 address, if the address is an unspecified address, it is invalid."
|
|
::= { hwNDRateLimitEntry 11 }
|
|
|
|
hwNDLimitPeVLAN OBJECT-TYPE
|
|
SYNTAX Unsigned32(0..4094)
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Outer VLAN ID."
|
|
::= { hwNDRateLimitEntry 12 }
|
|
|
|
hwNDLimitCeVLAN OBJECT-TYPE
|
|
SYNTAX Unsigned32(0..4094)
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Inner VLAN ID."
|
|
::= { hwNDRateLimitEntry 13 }
|
|
|
|
-- =================================================================
|
|
-- 7th slot nd proxy entries alarm
|
|
-- =================================================================
|
|
hwNDProxyObject OBJECT IDENTIFIER ::= { hwNDObjects 7 }
|
|
|
|
|
|
hwNDProxyThresholdExceedValue OBJECT-TYPE
|
|
SYNTAX Unsigned32(1..100)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates an ND entry alarm threshold on a board. An ND entry threshold-exceeding alarm is generated when the ratio of the number of ND proxy entries on a board to the maximum number allowed is greater than or equal to the alarm threshold."
|
|
::= { hwNDProxyObject 1 }
|
|
|
|
hwNDProxyThresholdResumeValue OBJECT-TYPE
|
|
SYNTAX Unsigned32(1..100)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates an ND entry clear alarm threshold on a board. An ND entry clear alarm is generated when the ratio of the number of ND proxy entries on a board to the maximum number allowed is less than or equal to the clear alarm threshold."
|
|
::= { hwNDProxyObject 2 }
|
|
|
|
hwNDProxyDynamicNumber OBJECT-TYPE
|
|
SYNTAX Unsigned32(0..4294967294)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Current dynamic ND entries in slot."
|
|
::= { hwNDProxyObject 3 }
|
|
|
|
|
|
|
|
-- Notifications(trap) Definitions
|
|
|
|
hwNDNotifications OBJECT IDENTIFIER ::= { hwNDMIB 2 }
|
|
|
|
hwSlotNDThresholdExceedAlarm NOTIFICATION-TYPE
|
|
OBJECTS { entPhysicalName, hwNDSlotThresholdExceedValue,hwNDSlotDynamicNumber,hwNDSlotStaticNumber,hwNDSlotRemoteNumber }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates that an alarm is generated when the ratio of the number of ND entries on a board to the maximum number of ND entries supported on the board is greater than or equal to the 80% threshold."
|
|
::= { hwNDNotifications 1 }
|
|
|
|
hwSlotNDThresholdResumeAlarm NOTIFICATION-TYPE
|
|
OBJECTS { entPhysicalName,hwNDSlotThresholdResumeValue,hwNDSlotDynamicNumber,hwNDSlotStaticNumber,hwNDSlotRemoteNumber }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates that a clear alarm is generated when the ratio of the number of ND entries on a board to the maximum number of ND entries supported on the board is less than or equal to the 70% threshold."
|
|
::= { hwNDNotifications 2 }
|
|
|
|
hwInterfaceNDThresholdExceedAlarm NOTIFICATION-TYPE
|
|
OBJECTS { entPhysicalName,ifDescr,hwNDIntfThresholdExceedValue,hwNDIntfDynamicNumber,hwNDIntfStaticNumber,hwNDIntfRemoteNumber }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates that an alarm is generated when the ratio of the number of ND entries on an interface to the maximum number of ND entries supported on the interface is greater than or equal to the 80% threshold."
|
|
::= { hwNDNotifications 3 }
|
|
|
|
hwInterfaceNDThresholdResumeAlarm NOTIFICATION-TYPE
|
|
OBJECTS { entPhysicalName,ifDescr,hwNDIntfThresholdResumeValue,hwNDIntfDynamicNumber,hwNDIntfStaticNumber,hwNDIntfRemoteNumber }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates that a clear alarm is generated when the ratio of the number of ND entries on an interface to the maximum number of ND entries supported on the interface is less than or equal to the 70% threshold."
|
|
::= { hwNDNotifications 4 }
|
|
|
|
hwNDHostIPConflict NOTIFICATION-TYPE
|
|
OBJECTS { hwNDHostBdId, hwNDHostIpv6Addr, hwNDHostLocalMAC,hwNDHostLocalIf,hwNDHostLocalPevid,hwNDHostLocalCevid,hwNDHostRemoteMAC,hwNDHostRemoteIf,hwNDHostRemotePevid,hwNDHostRemoteCevid }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates that an alarm is generated when there may be two host have the same IPv6 address."
|
|
::= { hwNDNotifications 5 }
|
|
|
|
hwNDHostIPConflictResume NOTIFICATION-TYPE
|
|
OBJECTS { hwNDHostBdId, hwNDHostIpv6Addr, hwNDHostLocalMAC,hwNDHostLocalIf,hwNDHostLocalPevid,hwNDHostLocalCevid,hwNDHostRemoteMAC,hwNDHostRemoteIf,hwNDHostRemotePevid,hwNDHostRemoteCevid }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates the clear alarm of the alarm generated when there may be two host have the same IPv6 address."
|
|
::= { hwNDNotifications 6 }
|
|
|
|
hwNDDuplicateIPv6 NOTIFICATION-TYPE
|
|
OBJECTS { hwNDDulicatePktType,hwNDDulicateTgtIPv6Addr,hwNDDulicateTgtIf,hwNDDulicateLocalIf,hwNDDulicateSrcMAC,hwNDDulicateDstMAC,hwNDDulicateSrcIPv6Addr,hwNDDulicateDstIPv6Addr,hwNDDulicatePeVLAN,hwNDDulicateCeVLAN,hwNDDulicateSelfLoop,hwNDDulicateDadAttempts }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates that an alarm is generated when customer config interface IPv6 address with the same as the current IPv6 address on the network."
|
|
::= { hwNDNotifications 7 }
|
|
|
|
hwNDDuplicateIPv6Resume NOTIFICATION-TYPE
|
|
OBJECTS { hwNDDulicatePktType,hwNDDulicateTgtIPv6Addr,hwNDDulicateTgtIf,hwNDDulicateLocalIf,hwNDDulicateSrcMAC,hwNDDulicateDstMAC,hwNDDulicateSrcIPv6Addr,hwNDDulicateDstIPv6Addr,hwNDDulicatePeVLAN,hwNDDulicateCeVLAN,hwNDDulicateSelfLoop,hwNDDulicateDadAttempts }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates the clear alarm of the alarm generated when there may not be an IPv6 address that has been used by any node to the interface"
|
|
::= { hwNDNotifications 8 }
|
|
|
|
hwNDDADNotFinished NOTIFICATION-TYPE
|
|
OBJECTS { hwNDDADIf, hwNDDADAddr, hwNDDADTimeout }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates that an alarm is generated when DAD is not finished."
|
|
::= { hwNDNotifications 9 }
|
|
|
|
hwNDAntiAttackRateLimit NOTIFICATION-TYPE
|
|
OBJECTS { hwNDLimitPacketType, hwNDLimitSuppressVal, hwNDLimitCurrentVal, hwNDLimitSuppressType, hwNDLimitIf, hwNDLimitWorkIf, hwNDLimitSrcMAC, hwNDLimitDstMAC, hwNDLimitSrcIP, hwNDLimitDstIP, hwNDLimitTargetIP, hwNDLimitPeVLAN, hwNDLimitCeVLAN }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates that an alarm is generated when ND packet or ND Miss message speed exceeds the rate limit."
|
|
::= { hwNDNotifications 10 }
|
|
|
|
hwNDProxyDynThresholdExceedAlarm NOTIFICATION-TYPE
|
|
OBJECTS { hwNDProxyThresholdExceedValue, hwNDProxyDynamicNumber }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates that an alarm is generated when the ratio of the number of proxy ND dynamic entries on a board to the maximum number of proxy ND entries supported on the board is greater than or equal to the 80% threshold."
|
|
::= { hwNDNotifications 11 }
|
|
|
|
hwNDProxyDynThresholdResumeAlarm NOTIFICATION-TYPE
|
|
OBJECTS { hwNDProxyThresholdResumeValue, hwNDProxyDynamicNumber }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates that a clear alarm is generated when the ratio of the number of proxy ND dynmic entries on a board to the maximum number of proxy ND entries supported on the board is less than or equal to the 70% threshold."
|
|
::= { hwNDNotifications 12 }
|
|
|
|
-- Conformance information
|
|
|
|
hwNDConformance OBJECT IDENTIFIER ::= { hwNDMIB 3 }
|
|
|
|
hwNDGroups OBJECT IDENTIFIER ::= { hwNDConformance 1 }
|
|
|
|
hwNDCompliances OBJECT IDENTIFIER ::= { hwNDConformance 2 }
|
|
|
|
hwNDSlotGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
hwNDSlotPhysicalIndex,
|
|
hwNDSlotThresholdExceedValue,
|
|
hwNDSlotThresholdResumeValue,
|
|
hwNDSlotDynamicNumber,
|
|
hwNDSlotStaticNumber,
|
|
hwNDSlotTotalNumber,
|
|
hwNDSlotRemoteNumber
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A collection of objects for ND threshold alarm in slot."
|
|
::= { hwNDGroups 1 }
|
|
|
|
hwNDIntfGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
hwNDIntfIndex,
|
|
hwNDIntfThresholdExceedValue,
|
|
hwNDIntfThresholdResumeValue,
|
|
hwNDIntfDynamicNumber,
|
|
hwNDIntfStaticNumber,
|
|
hwNDIntfTotalNumber,
|
|
hwNDIntfRemoteNumber
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A collection of objects for ND threshold alarm in interface."
|
|
::= { hwNDGroups 2 }
|
|
|
|
hwNDNotificationsGroup NOTIFICATION-GROUP
|
|
NOTIFICATIONS{ hwSlotNDThresholdExceedAlarm, hwSlotNDThresholdResumeAlarm, hwInterfaceNDThresholdExceedAlarm, hwInterfaceNDThresholdResumeAlarm, hwNDHostIPConflict, hwNDHostIPConflictResume, hwNDDuplicateIPv6, hwNDDuplicateIPv6Resume, hwNDDADNotFinished, hwNDAntiAttackRateLimit, hwNDProxyDynThresholdExceedAlarm , hwNDProxyDynThresholdResumeAlarm}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"notification Group."
|
|
::= { hwNDGroups 3 }
|
|
|
|
hwNDHostInfoGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
hwNDHostBdId,
|
|
hwNDHostIpv6Addr,
|
|
hwNDHostLocalMAC,
|
|
hwNDHostLocalIf,
|
|
hwNDHostLocalPevid,
|
|
hwNDHostLocalCevid,
|
|
hwNDHostRemoteMAC,
|
|
hwNDHostRemoteIf,
|
|
hwNDHostRemotePevid,
|
|
hwNDHostRemoteCevid
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A collection of objects for host IPv6 address conflict."
|
|
::= { hwNDGroups 4 }
|
|
|
|
hwNDDuplicateIPv6InfoGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
hwNDDulicatePktType,
|
|
hwNDDulicateTgtIPv6Addr,
|
|
hwNDDulicateTgtIf,
|
|
hwNDDulicateLocalIf,
|
|
hwNDDulicateSrcMAC,
|
|
hwNDDulicateDstMAC,
|
|
hwNDDulicateSrcIPv6Addr,
|
|
hwNDDulicateDstIPv6Addr,
|
|
hwNDDulicatePeVLAN,
|
|
hwNDDulicateCeVLAN,
|
|
hwNDDulicateSelfLoop,
|
|
hwNDDulicateDadAttempts
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A collection of objects for duplicate IPv6 address."
|
|
::= { hwNDGroups 5 }
|
|
|
|
hwNDDADInfoGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
hwNDDADIf,
|
|
hwNDDADAddr,
|
|
hwNDDADTimeout
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A collection of objects for DAD not finished."
|
|
::= { hwNDGroups 6 }
|
|
|
|
hwNDRateLimitGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
hwNDLimitPacketType,
|
|
hwNDLimitSuppressVal,
|
|
hwNDLimitCurrentVal,
|
|
hwNDLimitSuppressType,
|
|
hwNDLimitIf,
|
|
hwNDLimitWorkIf,
|
|
hwNDLimitSrcMAC,
|
|
hwNDLimitDstMAC,
|
|
hwNDLimitSrcIP,
|
|
hwNDLimitDstIP,
|
|
hwNDLimitTargetIP,
|
|
hwNDLimitPeVLAN,
|
|
hwNDLimitCeVLAN
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A collection of objects for ND packet or ND Miss message speed exceeding the rate limit."
|
|
::= { hwNDGroups 7 }
|
|
|
|
hwNDProxyGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
hwNDProxyThresholdExceedValue,
|
|
hwNDProxyThresholdResumeValue,
|
|
hwNDProxyDynamicNumber
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A collection of objects for ND proxy threshold alarm in slot."
|
|
::= { hwNDGroups 8 }
|
|
|
|
hwNDCompliance MODULE-COMPLIANCE
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The compliance statement for ND thre."
|
|
MODULE
|
|
MANDATORY-GROUPS {
|
|
hwNDSlotGroup,
|
|
hwNDIntfGroup,
|
|
hwNDProxyGroup
|
|
}
|
|
|
|
::= { hwNDCompliances 1 }
|
|
|
|
-- =================================================================
|
|
-- units of conformance
|
|
-- =================================================================
|
|
|
|
|
|
|
|
END
|