115 lines
4.2 KiB
Plaintext
115 lines
4.2 KiB
Plaintext
-- ============================================================================
|
|
-- Copyright (C) 2012 by HUAWEI TECHNOLOGIES. All rights reserved.
|
|
--
|
|
-- Description: HUAWEI-DETECT-ENGINE-MIB.mib
|
|
-- Reference:
|
|
-- Version: ver 1.0
|
|
-- History: ver 1.0 lijing00201194 2012-08-30 publish
|
|
--
|
|
-- ============================================================================
|
|
|
|
HUAWEI-DETECT-ENGINE-MIB DEFINITIONS ::= BEGIN
|
|
IMPORTS
|
|
hwDatacomm
|
|
FROM HUAWEI-MIB
|
|
OBJECT-GROUP, MODULE-COMPLIANCE, NOTIFICATION-GROUP
|
|
FROM SNMPv2-CONF
|
|
EnabledStatus
|
|
FROM P-BRIDGE-MIB
|
|
InterfaceIndex
|
|
FROM IF-MIB
|
|
SnmpAdminString
|
|
FROM SNMP-FRAMEWORK-MIB
|
|
Integer32, Unsigned32, Counter64, BITS, OBJECT-TYPE, MODULE-IDENTITY, NOTIFICATION-TYPE
|
|
FROM SNMPv2-SMI
|
|
DateAndTime, DisplayString, RowStatus, TEXTUAL-CONVENTION, AutonomousType
|
|
FROM SNMPv2-TC;
|
|
|
|
hwDetectEngineMIB MODULE-IDENTITY
|
|
LAST-UPDATED "201208300936Z" -- Aug 30, 2012 at 09:36 GMT
|
|
ORGANIZATION
|
|
"Huawei Technologies Co.,Ltd."
|
|
CONTACT-INFO
|
|
"Huawei Industrial Base
|
|
Bantian, Longgang
|
|
Shenzhen 518129
|
|
People's Republic of China
|
|
Website: http://www.huawei.com
|
|
Email: support@huawei.com
|
|
"
|
|
DESCRIPTION
|
|
"The HUAWEI-DETECT-ENGINE-MIB contains objects to configure Logic module,
|
|
including switching logic startup file.
|
|
This MIB module objects can switch logic startup file for NQA-RTP module or OAM module.
|
|
"
|
|
|
|
REVISION "201208300936Z" -- Aug 30, 2012 at 09:36 GMT
|
|
DESCRIPTION
|
|
"ver 1.0"
|
|
::= { hwDatacomm 308 }
|
|
|
|
|
|
-- 1.3.6.1.4.1.2011.5.25.308.1
|
|
hwDetectEngineObject OBJECT IDENTIFIER ::= { hwDetectEngineMIB 1 }
|
|
|
|
-- 1.3.6.1.4.1.2011.5.25.308.1.1
|
|
hwDetectEngineGlobalObjects OBJECT IDENTIFIER ::= { hwDetectEngineObject 1 }
|
|
|
|
-- 1.3.6.1.4.1.2011.5.25.308.1.1.1
|
|
hwDetectEngineOAMEnable OBJECT-TYPE
|
|
SYNTAX EnabledStatus
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Globally enable or disable the detect-engine for oam. If the hwDetectEngineOAMEnable is 1,
|
|
detect-engine for oam is enabled. If the hwDetectEngineOAMEnable is 2, detect-engine for oam is disabled.
|
|
By default, detect-engine for oam is enabled."
|
|
::= { hwDetectEngineGlobalObjects 1 }
|
|
|
|
-- 1.3.6.1.4.1.2011.5.25.308.1.1.2
|
|
hwDetectEngineNQAEnable OBJECT-TYPE
|
|
SYNTAX EnabledStatus
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Globally enable or disable the detect-engine for nqa-rtp. If the hwDetectEngineNQAEnable
|
|
is 1, detect-engine for nqa-rtp is enabled. If the hwDetectEngineNQAEnable is 2, detect-engine for nqa-rtp is disabled.
|
|
By default, detect-engine for nqa-rtp is disabled."
|
|
::= { hwDetectEngineGlobalObjects 2 }
|
|
|
|
|
|
-- 1.3.6.1.4.1.2011.5.25.308.100
|
|
hwDetectEngineConformance OBJECT IDENTIFIER ::= { hwDetectEngineMIB 100 }
|
|
|
|
|
|
-- 1.3.6.1.4.1.2011.5.25.308.100.1
|
|
hwDetectEngineCompliances OBJECT IDENTIFIER ::= { hwDetectEngineConformance 1 }
|
|
|
|
|
|
-- 1.3.6.1.4.1.2011.5.25.308.100.1.1
|
|
hwDetectEngineCompliance MODULE-COMPLIANCE
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Compliance statement for agents that provide full support for
|
|
hwDetectEngineMIB."
|
|
MODULE -- this module
|
|
MANDATORY-GROUPS { hwDetectEngineGlobalObjectGroup }
|
|
::= { hwDetectEngineCompliances 1 }
|
|
|
|
|
|
-- 1.3.6.1.4.1.2011.5.25.308.100.2
|
|
hwDetectEngineGroups OBJECT IDENTIFIER ::= { hwDetectEngineConformance 2 }
|
|
|
|
|
|
-- 1.3.6.1.4.1.2011.5.25.308.100.2.1
|
|
hwDetectEngineGlobalObjectGroup OBJECT-GROUP
|
|
OBJECTS { hwDetectEngineOAMEnable, hwDetectEngineNQAEnable}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Group for base trap objects."
|
|
::= { hwDetectEngineGroups 1 }
|
|
|
|
|
|
|
|
END
|