-- Copyright (C) 2012 by HUAWEI TECHNOLOGIES. All rights reserved.
--
-- Description: HUAWEI-DETECT-ENGINE-MIB.mib
-- Reference:
-- Version: ver 1.0
-- History: ver 1.0 lijing00201194 2012-08-30 publish
--
-- ============================================================================
HUAWEI-DETECT-ENGINE-MIB DEFINITIONS ::= BEGIN
IMPORTS
hwDatacomm
FROM HUAWEI-MIB
OBJECT-GROUP, MODULE-COMPLIANCE, NOTIFICATION-GROUP
FROM SNMPv2-CONF
EnabledStatus
FROM P-BRIDGE-MIB
InterfaceIndex
FROM IF-MIB
SnmpAdminString
FROM SNMP-FRAMEWORK-MIB
Integer32, Unsigned32, Counter64, BITS, OBJECT-TYPE, MODULE-IDENTITY, NOTIFICATION-TYPE
FROM SNMPv2-SMI
DateAndTime, DisplayString, RowStatus, TEXTUAL-CONVENTION, AutonomousType
FROM SNMPv2-TC;
hwDetectEngineMIB MODULE-IDENTITY
LAST-UPDATED "201208300936Z" -- Aug 30, 2012 at 09:36 GMT
ORGANIZATION
"Huawei Technologies Co.,Ltd."
CONTACT-INFO
"Huawei Industrial Base
Bantian, Longgang
Shenzhen 518129
People's Republic of China
Website: http://www.huawei.com
Email: support@huawei.com
"
DESCRIPTION
"The HUAWEI-DETECT-ENGINE-MIB contains objects to configure Logic module,
including switching logic startup file.
This MIB module objects can switch logic startup file for NQA-RTP module or OAM module.
"
REVISION "201208300936Z" -- Aug 30, 2012 at 09:36 GMT
DESCRIPTION
"ver 1.0"
::= { hwDatacomm 308 }
-- 1.3.6.1.4.1.2011.5.25.308.1
hwDetectEngineObject OBJECT IDENTIFIER ::= { hwDetectEngineMIB 1 }
-- 1.3.6.1.4.1.2011.5.25.308.1.1
hwDetectEngineGlobalObjects OBJECT IDENTIFIER ::= { hwDetectEngineObject 1 }
-- 1.3.6.1.4.1.2011.5.25.308.1.1.1
hwDetectEngineOAMEnable OBJECT-TYPE
SYNTAX EnabledStatus
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Globally enable or disable the detect-engine for oam. If the hwDetectEngineOAMEnable is 1,
detect-engine for oam is enabled. If the hwDetectEngineOAMEnable is 2, detect-engine for oam is disabled.
By default, detect-engine for oam is enabled."
::= { hwDetectEngineGlobalObjects 1 }
-- 1.3.6.1.4.1.2011.5.25.308.1.1.2
hwDetectEngineNQAEnable OBJECT-TYPE
SYNTAX EnabledStatus
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Globally enable or disable the detect-engine for nqa-rtp. If the hwDetectEngineNQAEnable
is 1, detect-engine for nqa-rtp is enabled. If the hwDetectEngineNQAEnable is 2, detect-engine for nqa-rtp is disabled.
By default, detect-engine for nqa-rtp is disabled."
::= { hwDetectEngineGlobalObjects 2 }
-- 1.3.6.1.4.1.2011.5.25.308.100
hwDetectEngineConformance OBJECT IDENTIFIER ::= { hwDetectEngineMIB 100 }
-- 1.3.6.1.4.1.2011.5.25.308.100.1
hwDetectEngineCompliances OBJECT IDENTIFIER ::= { hwDetectEngineConformance 1 }
-- 1.3.6.1.4.1.2011.5.25.308.100.1.1
hwDetectEngineCompliance MODULE-COMPLIANCE
STATUS current
DESCRIPTION
"Compliance statement for agents that provide full support for
hwDetectEngineMIB."
MODULE -- this module
MANDATORY-GROUPS { hwDetectEngineGlobalObjectGroup }
::= { hwDetectEngineCompliances 1 }
-- 1.3.6.1.4.1.2011.5.25.308.100.2
hwDetectEngineGroups OBJECT IDENTIFIER ::= { hwDetectEngineConformance 2 }
-- 1.3.6.1.4.1.2011.5.25.308.100.2.1
hwDetectEngineGlobalObjectGroup OBJECT-GROUP
OBJECTS { hwDetectEngineOAMEnable, hwDetectEngineNQAEnable}
STATUS current
DESCRIPTION
"Group for base trap objects."
::= { hwDetectEngineGroups 1 }
END