Observium_CE/mibs/huawei/HUAWEI-CLK-MIB

5591 lines
270 KiB
Plaintext

-- ============================================================================
-- Copyright (C) 2018 by HUAWEI TECHNOLOGIES. All rights reserved.
-- Description: This MIB is used for defining clock management
-- MIB objects.
-- Reference:
-- Version: V1.55
-- =============================================================================
HUAWEI-CLK-MIB DEFINITIONS ::= BEGIN
IMPORTS
huaweiUtility
FROM HUAWEI-MIB
IpAddress, Integer32, OBJECT-TYPE, MODULE-IDENTITY,NOTIFICATION-TYPE
FROM SNMPv2-SMI
RowStatus, TruthValue,DisplayString, MacAddress
FROM SNMPv2-TC
ifIndex
FROM IF-MIB
hwFrameIndex,hwSlotIndex,hwSubslotIndex,hwPortIndex,hwConfigChangeIP
FROM HUAWEI-DEVICE-MIB;
hwClk MODULE-IDENTITY
LAST-UPDATED "201809210000Z"
ORGANIZATION "Huawei Technologies Co.,Ltd."
CONTACT-INFO
"Huawei Industrial Base
Bantian, Longgang
Shenzhen 518129
People's Republic of China
Website: http://www.huawei.com
Email: support@huawei.com
"
DESCRIPTION
"This MIB is used for defining clock management MIB objects."
-- Revision history
REVISION "201809210000Z"
DESCRIPTION "V1.55, Modify the ont clock manage table"
REVISION "201809050000Z"
DESCRIPTION "V1.54, Add the ont clock manage table"
REVISION "201803290000Z"
DESCRIPTION "V1.53, Modify the value of range of hwPtpBitsOffsetScaledLogVariance."
REVISION "201802260000Z"
DESCRIPTION "V1.52, Modify the type of hw1588ACRPdvState to string."
REVISION "201708210000Z"
DESCRIPTION "V1.51, Add hwClkPdvStateChangeTrap of hwClkAlarmTrapsPrefix.
Add hwClkPtpaTraceSourceChangeTrap of hwClkAlarmTrapsPrefix. "
REVISION "201702170000Z"
DESCRIPTION "V1.50, Add hwClkSysClockLockFailTrap of hwClkAlarmTrapsPrefix.
Add hwClkSysClockLockRecoverTrap of hwClkAlarmTrapsPrefix. "
REVISION "201609200000Z"
DESCRIPTION "V1.49, Modify the value of range of hwPtpLocalSourceLocalPriority."
REVISION "201602160000Z"
DESCRIPTION "V1.48, Added and modified the following nodes to comply with ITU-T G.8275.1.
Add:
hwPtpLocalSourceLocalPriority
hwPtpLocalSourcePriority2
hw1588ClkPtpPortNotSlave
hw1588ClkPtpPortLocalPriority
hwPtpBitsPortLocalPriority
hwPtpBitsOffsetScaledLogVariance
Modify:
hw1588ClkType
hwPtpDomain
hwPtpBMCEnable
hw1588ClkPtpPortAnnounceTimeout
hw1588ClkPtpPortMacDestinationMac
hw1588ClkPtpPortDelayMechanism
hw1588ClkPtpPortUdpDestinationMac
hw1588ClkPtpPortUdpEgressSourceIp
hw1588ClkPtpPortUdpEgressDestinationIp
hw1588ClkPtpPortUdpVlanPRI
hw1588ClkPtpPortMacVlanPRI
hw1588ClkPtpPortUdpEgressDscp
hw1588ClkPtpPortUdpVlan
hw1588ClkPtpPortMacVlan
hw1588ClkPtpPortAnnounceSendTimeInterval
hw1588ClkPtpPortSyncSendTimeInterval
hw1588ClkPtpPortReqSendTimeInterval
hwPtpBitsClockAccuracy
hwPtpBitsClockClass
hwPtpBitsPriority1
hw1588ClkPtpPortLineWarpValue
"
REVISION "201511110000Z"
DESCRIPTION "V1.47, Add hwClkFreqDeviation of HwClockInManageEntry."
REVISION "201510280000Z"
DESCRIPTION "V1.46, Add hwClkOutExternalClosedTrap of hwClkAlarmTrapsPrefix.
Add hwClkOutExternalOpenedTrap of hwClkAlarmTrapsPrefix.
Add hwExtClkOutputState for external clock output state."
REVISION "201504150000Z"
DESCRIPTION "V1.45, Correct the description of node hwClkOutType and hwClkOutTypeTrapSn."
REVISION "201412160000Z"
DESCRIPTION "V1.44, Correct the node hwClkRowStatus from read-write to read-create."
REVISION "201409120000Z"
DESCRIPTION "V1.43, Add hwClkQlFailTrap of hwClkAlarmTrapsPrefix.
Add hwClkQlRestoreTrap of hwClkAlarmTrapsPrefix."
REVISION "201408180000Z"
DESCRIPTION "V1.42, Modify the value range of the node.
hw1588ClkPtpPortUdpVlanPRI
hw1588ClkPtpPortMacVlanPRI
hw1588ClkPtpPortUdpEgressDscp
hw1588ClkPtpPortUdpVlan
hw1588ClkPtpPortMacVlan
hwPtpPortRingFiberLengthChangeValue."
REVISION "201406230000Z"
DESCRIPTION "V1.41, Modify the following not normative nodes to satisfy for the new OMSYS tool.
hwClock
hwClkInIndex
hwExtClkOutputMode
hw1588ClkInIndex
hwPtpBitsClockAccuracy
hw1588ClkPtpPortDelayMechanism
hw1588ClkPtpPortClockStep
hw1588ACRNegotiateState
hw1588ACRNegoMode
hw1588ACRServerSsm."
REVISION "201312100000Z"
DESCRIPTION "V1.40, Modify node hw1588ClkPtpPortUdpVlan and hw1588ClkPtpPortMacVlan 's sizelist."
REVISION "201309030000Z"
DESCRIPTION "V1.39, Add hw1588ACRServerTable of 1588ACR;
Add hw1588ACRDfx and hw1588ACRServerEntry of 1588ACR;
Add the following leaf nodes on hw1588ACRManage: hw1588ACRGlbEnable,
hw1588ACRDeviceType,
hw1588ACRVpnInstance,
hw1588ACRAnnounceInterval,
hw1588ACRSyncInterval,
hw1588ACRDelayRespInterval,
hw1588ACRAnnounceDuration,
hw1588ACRSyncDuration,
hw1588ACRDelayRespDuration,
hw1588ACRNegoMode,
hw1588ACRNegoEnable,
hw1588ACRTraceSourceId
"
REVISION "201308080000Z"
DESCRIPTION "V1.38, Added pvx2m for getting/setting clock source PVX-2M.
"
REVISION "201307310000Z"
DESCRIPTION "V1.37, Add obsolete tags for those abandoned nodes.
"
REVISION "201305300000Z"
DESCRIPTION "V1.36, Modify some mibs which aren't true according to the simpletester.
"
REVISION "201303180000Z"
DESCRIPTION "V1.35, Add hwPtpParentClockID for ptp parent clockID.
add hwPtpParentPortNumber for ptp parent portnumber.
add hw1588ClkInSelectStatus to indicate whether the time source is selected.
modify the parameter of hwClkGmcclockIdChangeTrap.
modify the parameter of hwClkTimeSourcePortIdentityTrap.
"
REVISION "201211060000Z"
DESCRIPTION "V1.34, Add hwPtpBitsClockAccuracy for clock accuracy.
add hwPtpBitsClockClass for clock class.
add hwPtpBitsPriority1 for clock priority 1.
add hwPtpBitsPriority2 for clock priority 2.
add hwPtpBitsTimeSource for time source.
add hwBits1ppsDelayDirection and hwBits1ppsDelayValue for clock warp.
add hwPtpDomain for PTP domain.
add hwPtpBMCEnable for PTP BMC switch.
add hwPtpLockState for PTP lock state.
add hwPtpFreqLockStatus for PTP frequency lock state.
add hwPtpTimeScale for the time scale of PTP.
add hwPtpFrequencyTraceable for PTP Frequency Traceable.
add hwPtpTimeTraceable for PTP Time Traceable.
add hwPtpGMClockID for Grand Master Clock ID.
add hwPtpGrandMasterClockPriority1 for Grand Master Clock Priority1.
add hwPtpGrandMasterClockPriority2 for Grand Master Clock Priority2.
add hwPtpGrandMasterClockAccuracy for Grand Master Clock Accuracy.
add hwPtpGrandMasterClockClass for Grand Master Clock Class.
add hwPtpGrandMasterClockTimeSource for PTP GrandMaster clock timesource attribute.
add hwPtpPhyPhaseSubCur for PTP physics phase current warp.
add hwPtpPhyPhaseSubMin for PTP physics phase min warp.
add hwPtpPhyPhaseSubMax for PTP physics phase max warp.
add hwPtpPhyPhaseSubMean for PTP physics phase mean warp.
add hwPtpTimeSyncOffsetCur for PTP current time offset.
add hwPtpTimeSyncOffsetMin for PTP min time offset.
add hwPtpTimeSyncOffsetMax for PTP max time offset.
add hwPtpTimeSyncOffsetMean for PTP average time offset.
add hwPtpTimeMeanpathdelayCur for PTP current path delay.
add hwPtpTimeMeanpathdelayMin for PTP min path delay.
add hwPtpTimeMeanpathdelayMax for PTP max path delay.
add hwPtpTimeMeanpathdelayMean for PTP average path delay.
add hwPtpDlyMeasureEnable for ptp asymmetry measure switch.
add hw1588ClkPtpPortDelayMechanism for delay mechanism.
add hw1588ClkPtpPortMacDestinationMac for PTP port MAC egress destination MAC address.
add hw1588ClkPtpPortUdpDestinationMac for PTP port UDP egress destination MAC address.
add hw1588ClkPtpPortUdpEgressSourceIp for PTP port UDP egress source IP address.
add hw1588ClkPtpPortUdpEgressDestinationIp for PTP port UDP egress destination IP address.
add hw1588ClkPtpPortUdpVlanPRI for PTP port UDP egress packet priority.
add hw1588ClkPtpPortMacVlanPRI for PTP port Mac egress packet priority.
add hw1588ClkPtpPortUdpEgressDscp for PTP port UDP egress dscp value.
add hw1588ClkPtpPortClockStep for clock step mode.
add hw1588ClkPtpPortUdpVlan for PTP port UDP egress vlan ID.
add hw1588ClkPtpPortMacVlan for PTP port MAC egress vlan ID.
Modified the encoding rule of hwClkInPostion's value .
"
REVISION "201205200000Z"
DESCRIPTION "V1.33,Added hwClkEsmcLoseTrap, hwClkEsmcRestoreTrap and hwClkQlChangeTrap."
REVISION "201201050000Z"
DESCRIPTION "V1.32,Modified hwExtClkOutputBitsType's enumerated value.
Modified hwClkInBitsImpedance's enumerated value.
Modified hwClkInBitsType's enumerated value."
REVISION "201111220000Z"
DESCRIPTION "V1.31, implemented DT requirements and changed the syntax and semantics of SIMPLETEST.
Modified hwSubslotIndex from hwSubSlotIndex for compiling problem.
Modified hwClkHoldoffTime's enumerated value.
Added hwQlInputLowerLimit"
REVISION "201010120000Z"
DESCRIPTION "V1.30, add the objects of hwClkNoTraceTrap and hwClkNoTraceRecoversTrap for standard traps.
Added hwClkOutTypeTrapSn to hwClkNoTraceTrap and hwClkNoTraceRecoversTrap.
"
REVISION "201007200000Z"
DESCRIPTION "V1.29, modified the objects of hwClkGmcclockIdChangeTrap and hwClkTimeSourcePortIdentityTrap for standard traps.
Added hw3rdClkOldSubBoardWorkMode to hwClkSubcardWorkmodeSwitchesTrap.
"
REVISION "201007030000Z"
DESCRIPTION "V1.28, added hwExtClkOutputBitsType for getting/setting output signals of the GPIO board."
REVISION "201005060000Z"
DESCRIPTION "V1.27, added hw1588ClkInWorkMode for getting/setting time source work mode.
Added enum ppsnmea(3) to hwBitsPortTimeWorkMode.
Modified pps(1) to ppsubx(1) in hwBitsPortTimeWorkMode.
Added hwClkLockState for getting clock source lock state.
Added hwPTPEnable for enabling current 1588v2 or 1588ACR function.
Added hw1588ClkDSCP for getting/setting clock source dscp.
Added hw1588ClkVlanPRI for getting/setting the clock source VLAN priority.
Added hw1588ACRReqSendTimeInterval for getting/setting the transmit interval of time source request packets.
Added hw1588ACRSourceIp for getting/setting time source IP address.
Added hw1588ACRDSCP for getting/setting time source dscp.
Added hw1588ACRVlan for getting/setting time source VLAN.
Added hw1588ACRVlanPRI for getting/setting time source VLAN priority.
"
REVISION "201004120000Z"
DESCRIPTION "V1.26, modified the MIB for clearing simple testing errors and warnings and added hwQlOutputUpperLimit."
REVISION "201003240000Z"
DESCRIPTION "V1.25, added hw1588ClkPtpPortMsgFormat, hw1588ClkPtpPortInfoMode, hw1588ClkPtpPortAnnounceSendTimeInterval,
hw1588ClkPtpPortSyncSendTimeInterval, hw1588ClkPtpPortReqSendTimeInterval, hw1588ClkPtpPortLineWarpMode,
hw1588ClkPtpPortLineWarpDirect, hw1588ClkPtpPortLineWarpValue, hw1588ClkPtpPortAnnounceTimeout, and
hw1588ClkPtpPortDomainNum for the 1588 clock.
"
REVISION "201002020000Z"
DESCRIPTION "V1.24,Modified description."
REVISION "201001070000Z"
DESCRIPTION "V1.23,Modified hwExtClkoutputThresholdSsmQl."
REVISION "200912010000Z"
DESCRIPTION "V1.22,Modified hwClkInQL's enumerated value."
REVISION "200911170000Z"
DESCRIPTION "V1.21,Added hwClkInQL, hwClkInFaultRecord, and hwClkInClearFaultRecord."
REVISION "200910160000Z"
DESCRIPTION "V1.20,Added hwBitsPortManageTable."
REVISION "200906150000Z"
DESCRIPTION "V1.19,Added hwACMClockIPTable."
REVISION "200906050000Z"
DESCRIPTION "V1.18,Added hwClockTransManageTable."
REVISION "200906040000Z"
DESCRIPTION "V1.17,Added pw(15) and copa(16) to hwClkInWorkMode."
REVISION "200906030000Z"
DESCRIPTION "V1.16,Added 11 new columns to hwClock1588ManageTable."
REVISION "200902180000Z"
DESCRIPTION "V1.15,Added bits_type_64K(3) to hwClkInBitsType and added bits_impedance_110ohm to hwClkInBitsImpedance."
REVISION "200812150000Z"
DESCRIPTION "V1.14,Added hwClock1588ManageTable."
REVISION "200705120000Z"
DESCRIPTION "V1.13,Added hwClkInBitsType."
REVISION "200704170000Z"
DESCRIPTION "V1.12,Added hwClkInBitsImpedance."
REVISION "200611200000Z"
DESCRIPTION "V1.11,Modified the MIB according to standard specification."
REVISION "200608100000Z"
DESCRIPTION "V1.10,Added hwClkOutputPostion and hwClkOutPortEnable."
REVISION "200411010000Z"
DESCRIPTION "V1.01,Added hwUASystemWorkMode and hw3rdClkSubBoardWorkMode."
REVISION "200305120000Z"
DESCRIPTION "V1.00, Initial version."
::= { huaweiUtility 25 }
--
-- Node definitions
--
-- 1.3.6.1.4.1.2011.6.25.1
hwClkMibObjects OBJECT IDENTIFIER ::= { hwClk 1 }
-- 1.3.6.1.4.1.2011.6.25.1.1
hwClockInManageTable OBJECT-TYPE
SYNTAX SEQUENCE OF HwClockInManageEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Clock Source Management Table.
This table is used to add or delete the clock source and query
the status of the clock source.
The index of this table is hwClkInIndex, which is the clock source ID.
"
::= { hwClkMibObjects 1 }
-- 1.3.6.1.4.1.2011.6.25.1.1.1
hwClockInManageEntry OBJECT-TYPE
SYNTAX HwClockInManageEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Clock Source Management Table.
This table is used to add or delete the clock source and query
the status of the clock source.
The index of this entry is hwClkInIndex, which is the clock source ID.
"
INDEX { hwClkInIndex }
::= { hwClockInManageTable 1 }
HwClockInManageEntry ::=
SEQUENCE {
hwClkInIndex
Integer32,
hwClkInPostion
Integer32,
hwClkInWorkMode
INTEGER,
hwClkInOperStatus
INTEGER,
hwClkInRowStatus
RowStatus,
hwClkInBitsImpedance
INTEGER,
hwClkInBitsType
INTEGER,
hwClkInQL
INTEGER,
hwClkInFaultRecord
INTEGER,
hwClkInClearFaultRecord
INTEGER,
hwClkLockState
INTEGER,
hwClkFreqDeviation
Integer32
}
-- 1.3.6.1.4.1.2011.6.25.1.1.1.1
hwClkInIndex OBJECT-TYPE
SYNTAX Integer32 (0..9 | 255)
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"Clock source index: ranging from 0 to 9. The value 255 indicates the local
clock source.
Range: 0-9 | 255
"
::= { hwClockInManageEntry 1 }
-- 1.3.6.1.4.1.2011.6.25.1.1.1.2
hwClkInPostion OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The ifIndex of physical position of clock source. If the clock source
isn't a sysline clock, the value will be 0xFFFFFFFFFFFFFF.
The first byte indicates the NO. of CESoP index.
The second byte indicates the NO. of frame,
the third byte indicates the NO. of slot and
the lowest byte indicates the port ID.
The following shows how to use parameter during the get or set operation:
0x 01, 00,00,00 Cesop ID; 0~1
0x 02, 00,00,00 System clock as an external clock
0x 03, 00,00,00 1588 clock as an system clock
0x 00, FF,00,00 Frame ID; 0~255
0x 00, 00,FF,00 Slot ID; 0~255
0x 00, 00,00,FF Port ID; 0~255
"
::= { hwClockInManageEntry 2 }
-- 1.3.6.1.4.1.2011.6.25.1.1.1.3
hwClkInWorkMode OBJECT-TYPE
SYNTAX INTEGER
{
none(1),
sysLine(2),
cesLine(3),
cesSrts(4),
e1Bits0(5),
e1Bits1(6),
f2mhzBits0(7),
f2mhzBits1(8),
msuSdh(9),
msuTdm(10),
localSurge(11),
xpm8k(12),
gPON(13),
pkt1588(14),
pw(15),
copa(16),
adaptClock(17),
aCMClock(18),
t1Bits0(19),
t1Bits1(20),
system(21),
acr1588(22),
syncEth(23),
pvx2m(24)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Clock source type.
Includes the line clock source, BITS clock source, and local surge source.
If it is line clock source of a CES port, the clock source type may be CES line or CES SRTS clock source.
If it is BITS clock source, the clock source type may be 2 MHZ or EL clock source of BITS0, or 2 MHZ or EL clock source of BITS1.
If the value is 1, it indicates that a clock source is not configured.
Options:
1.none(1) - indicates that clock source not configured
2.sysLine(2) - indicates that line clock source that needs to specify frame/slot/port
3.cesLine(3) - indicates that line_clk of a CES clock source
4.cesSrts(4) - indicates that srts_clk of a CES clock source
5.e1Bits0(5) - indicates that EL type of a BITS0 clock source
6.e1Bits1(6) - indicates that EL type of a BITS1 clock source
7.f2mhzBits0(7) - indicates that 2MHZ type of a BITS0 clock source
8.f2mhzBits1(8) - indicates that 2MHZ type of a BITS1 clock source
9.msuSdh(9) - indicates that sdh_clk of an MSU clock source
10.msuTdm(10) - indicates that tdm_clk of an MSU clock source
11.localSurge(11) - indicates that local surge clock
12.xpm8k(12) - indicates that xpm-8k type of a xpm-8k clock source
13.gPON(13) - indicates that 2MHZ type of a clock source at H601GP1A board
14.pkt1588(14) - indicates that frequency synchronization from 1588
15.pw(15) - indicates that Pseudo-Wire clock source
16.copa(16) - indicates that EL clock source of H601COPA board
17.adaptClock(17) - indicates that clock adapt from CESoP
18.aCMClock(18) - indicates that ACM clock
19.t1Bits0(19) - indicates that TL type of a BITS0 clock source
20.t1Bits1(20) - indicates that TL type of a BITS1 clock source
21.system(21) - indicates that system clock source
22.acr1588(22) - indicates that 1588ACR clock source
23.syncEth(23) - indicates that syncEth clock source
24.pvx2m(24) - indicates that PVX-2M clock source
"
::= { hwClockInManageEntry 3 }
-- 1.3.6.1.4.1.2011.6.25.1.1.1.4
hwClkInOperStatus OBJECT-TYPE
SYNTAX INTEGER
{
none(1),
normal(2),
failure(3),
failureLoss(4),
failureEFD(5)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Clock source state.
Options:
1.none(1) - indicates that the clock source index isn't configured
2.normal(2) - indicates that the state of the clock source is active
3.failure(3) - indicates that the state of the clock source fails and this leaf is not used on the OLT
4.failureLoss(4) - indicates that the clock source fails due to signal loss
5.failureEFD(5) - indicates that the clock source fails due to frequency offset
"
::= { hwClockInManageEntry 4 }
-- 1.3.6.1.4.1.2011.6.25.1.1.1.5
hwClkInRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Clock Source operation:
A user can add a clock source or clear a clock source.
After a user adds a clock source,the clock works in trace mode.
After a user clears a clock source, the clock works in srystal mode.
To set the position(frame,slot,port) and oper(4), these two operations
must be set together.
Oper(6) can be set by itself. To set a BITS clock source,
the frame,slot,port parameters are useless.
Oper(6) is used to clear a clock source.
"
::= { hwClockInManageEntry 5 }
-- 1.3.6.1.4.1.2011.6.25.1.1.1.6
hwClkInBitsImpedance OBJECT-TYPE
SYNTAX INTEGER
{
bitsImpedance75ohm(1),
bitsImpedance120ohm(2),
bitsImpedance110ohm(3),
bitsImpedance100ohm(4),
bitsImpedanceNone(255)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"BITS clock impedance type.The impedance value must be set when the clock source is a bits clock.
Options:
1. bitsImpedance75ohm(1) - indicates that the impedance of this BITS clock source is 75 ohm
2. bitsImpedance120ohm(2) - indicates that the impedance of this BITS clock source is 120 ohm
3. bitsImpedance110ohm(3) - indicates that the impedance of this BITS clock source is 110 ohm
4. bitsImpedance100ohm(4) - indicates that the impedance of this BITS clock source is 100 ohm
5. bitsImpedanceNone(255) - indicates that this clock source is not a BITS clock
"
::= { hwClockInManageEntry 6 }
-- 1.3.6.1.4.1.2011.6.25.1.1.1.7
hwClkInBitsType OBJECT-TYPE
SYNTAX INTEGER
{
bitsType2MHz(1),
bitsType2Mbps(2),
bitsType64K(3),
bitsType1544bps(4),
bitsTypeNone(255)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"BITS clock type:
Options:
1.bitsType2MHz(1) - indicates that the BITS clock type is 2MHz
2.bitsType2Mbps(2) - indicates that the BITS clock type is 2bps
3.bitsType64K(3) - indicates that the BITS clock type is 64K
4.bitsType1544bps(4) - indicates that the BITS clock type is bitsType1.544Mbps
5.bitsTypeNone(255) - indicates that the clock source is not a BITS clock
The BITS clock type must be set when the clock source is a BITS clock.
"
::= { hwClockInManageEntry 7 }
-- 1.3.6.1.4.1.2011.6.25.1.1.1.8
hwClkInQL OBJECT-TYPE
SYNTAX INTEGER
{
qlPRC(2),
qlSsuA(4),
qlSsuB(8),
qlSEC(11),
qlDNU(15),
qlCLEAR(255)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Clock source quality level:
Options:
1. qlPRC(2) - indicates that primary reference clock
2. qlSsuA(4) - indicates that the clock signal comes from class I or class
V sub-clock prescribed on G.812 protocol
3. qlSsuB(8) - indicates that the clock signal comes from class VI sub-clock
prescribed on G.812 protocol
4. qlSEC(11) - indicates that the clock signal comes from SEC(SDH Equipment
Clock) prescribed on G.813 protocol
5. qlDNU(15) - indicates that the clock signal can't be used for synchronization
6. qlCLEAR(255) - indicates that it is a wrong clock quality level
"
::= { hwClockInManageEntry 8 }
-- 1.3.6.1.4.1.2011.6.25.1.1.1.9
hwClkInFaultRecord OBJECT-TYPE
SYNTAX INTEGER
{
noFaultRecord(1),
faultRecord(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Clock source fault record.
Options:
1.noFaultRecord(1) - indicates that there is no fault record
2.faultRecord(2) - indicates that the clock source had a fault record
"
::= { hwClockInManageEntry 9 }
-- 1.3.6.1.4.1.2011.6.25.1.1.1.10
hwClkInClearFaultRecord OBJECT-TYPE
SYNTAX INTEGER { clearFaultRecord(1) }
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Clear fault record of one clock source.
Options:
1.clearFaultRecord(1) -Clears fault records
"
::= { hwClockInManageEntry 10 }
-- 1.3.6.1.4.1.2011.6.25.1.1.1.11
hwClkLockState OBJECT-TYPE
SYNTAX INTEGER
{
locked(1),
unlocked(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Clock lock state.
Options:
1.locked(1) - indicates that the clock is locked
2.unlocked(2) - indicates that the clock is unlocked
"
::= { hwClockInManageEntry 11 }
-- 1.3.6.1.4.1.2011.6.25.1.1.1.12
hwClkFreqDeviation OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Clock source freq-deviation-value
The value is ten times of actual frequency deviation value
Unit: 0.1ppm
The invalid value is 0x7fffffff
"
::= { hwClockInManageEntry 12 }
-- 1.3.6.1.4.1.2011.6.25.1.2
hwClockOutManageTable OBJECT-TYPE
SYNTAX SEQUENCE OF HwClockOutManageEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Clock Out Management Table.
This table is used to configure and query the priority of the clock source,
and query the index of the currently-output clock source, and the working mode (the output mode)
of the current clock.The indexes of this table are hwClkInIndex and hwClkOutIndex.
hwClkInIndex comes from hwClockInManageTable and is the index of the input clock source.
hwClkOutIndex is the type of the output clock source.
The output clock source can be of the SDH, TDM, 8K, or 19M type.
"
::= { hwClkMibObjects 2 }
-- 1.3.6.1.4.1.2011.6.25.1.2.1
hwClockOutManageEntry OBJECT-TYPE
SYNTAX HwClockOutManageEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Clock Out Management Table.
This table is used to configure and query the priority of the clock source,
and query the index of the currently-output clock source, and the working mode (the output mode)
of the current clock.The indexes of this entry are hwClkInIndex and hwClkOutIndex.
hwClkInIndex comes from hwClockInManageTable and is the index of the input clock source.
hwClkOutIndex is the type of the output clock source.
The output clock source can be of the SDH, TDM, 8K, or 19M type.
"
INDEX { hwClkInIndex, hwClkOutIndex }
::= { hwClockOutManageTable 1 }
HwClockOutManageEntry ::=
SEQUENCE {
hwClkOutIndex
Integer32,
hwClkOutType
INTEGER,
hwClkOutPriority
Integer32,
hwClkOutWorkMode
INTEGER,
hwClkOutOperStatus
TruthValue
}
-- 1.3.6.1.4.1.2011.6.25.1.2.1.1
hwClkOutIndex OBJECT-TYPE
SYNTAX Integer32 (1..7)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Index of clock out table. Its meaning is the same as hwClkOutType.
The clock out index must be 8k in UA system and must be SDH or
TDM in MD/MA system during the setting of priority for a clock source.
Range: 1 - 7
"
::= { hwClockOutManageEntry 1 }
-- 1.3.6.1.4.1.2011.6.25.1.2.1.2
hwClkOutType OBJECT-TYPE
SYNTAX INTEGER
{
sdh(1),
tdm(2),
system(3),
clk19M(4),
systemObsolete(5),
external(6),
external1(7)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Clock out type.
Currently, there are seven types: SDH, TDM, system, 19 MHzm, systemObsolete, external and external1.
Options:
1.sdh(1) - indicates that output clock type is SDH
2.tdm(2) - indicates that output clock type is TDM
3.system(3) - indicates that output clock type is system
4.clk19M(4) - indicates that output clock type is clk19M
5.systemObsolete(5) - indicates that output clock type is systemObsolete
6.external(6) - indicates that output clock type is external
7.external1(7) - indicates that output clock type is external1
"
::= { hwClockOutManageEntry 2 }
-- 1.3.6.1.4.1.2011.6.25.1.2.1.3
hwClkOutPriority OBJECT-TYPE
SYNTAX Integer32 (0..9 | 255)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Clock source priority.
The priority ranges from 0 to 9 in a descending order. If the value is 255 in the get operation,
it indicates that the priority of the clock source isn't configured.
"
DEFVAL { 255 }
::= { hwClockOutManageEntry 3 }
-- 1.3.6.1.4.1.2011.6.25.1.2.1.4
hwClkOutWorkMode OBJECT-TYPE
SYNTAX INTEGER
{
trace(1),
surge(2),
keep(3),
snap(4),
thirdsurge(5)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Clock out working mode.
Options:
1.trace(1) - indicates that the clock is working in tracing mode
2.surge(2) - indicates that the clock is working in surge mode
3.keep(3) - indicates that the clock is working in keeping mode
4.snap(4) - indicates that the clock is working in snapping mode
5.thirdsurge(5) - indicates that the clock is working in thirdsurge mode
"
::= { hwClockOutManageEntry 4 }
-- 1.3.6.1.4.1.2011.6.25.1.2.1.5
hwClkOutOperStatus OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Clock source Out state. It indicates whether the clock source is
the output clock of the system: 1 indicates yes, and 2 indicates no.
Options:
1.yes(1) - indicates that the clock source is the output clock
2.no(2) - indicates that the clock source isn't the output clock
"
::= { hwClockOutManageEntry 5 }
-- 1.3.6.1.4.1.2011.6.25.1.3
hwSystemClockManagePara OBJECT IDENTIFIER ::= { hwClkMibObjects 3 }
-- 1.3.6.1.4.1.2011.6.25.1.3.1
hwUASystemWorkMode OBJECT-TYPE
SYNTAX INTEGER
{
olt(1),
onu(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"UA work mode.
Options:
1.olt(1) - indicates that the UA system works as an OLT in VPRING
2.onu(2) - indicates that the UA system works as an ONU in VPRING
"
::= { hwSystemClockManagePara 1 }
-- 1.3.6.1.4.1.2011.6.25.1.3.2
hw3rdClkSubBoardWorkMode OBJECT-TYPE
SYNTAX INTEGER
{
trace(1),
keep(2),
thirdsurge(3),
snap(4),
no3rdclksubboard(255)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Working mode of 3rd sub-board clock.
Options:
1. trace(1) - indicates that the clock is working in tracing mode
2. keep(2) - indicates that the clock is working in keeping mode
3. thirdsurge(3) - indicates that the clock is working in 3rd subboard crystal
4. snap(4) - indicates clock is working in snap mode
5. no3rdclksubboard(255) - indicates that there is no 3rd subboard
"
::= { hwSystemClockManagePara 2 }
-- 1.3.6.1.4.1.2011.6.25.1.3.3
hwSystemClockMode OBJECT-TYPE
SYNTAX INTEGER
{
clockClksubboard(1),
clockLocalboard(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"System clock mode.
Options:
1. clockClksubboard(1) - indicates the clock-subboard supply output clock
2. clockLocalboard(2) - indicates the local-board supply output clock
"
::= { hwSystemClockManagePara 3 }
-- 1.3.6.1.4.1.2011.6.25.1.3.4
hw3rdClkSubBoardInputStatus OBJECT-TYPE
SYNTAX INTEGER
{
none(1),
normal(2),
fault(3),
no3rdclksubboard(255)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Clock-subboard clock input status.
Options:
1.none(1) - indicates that the clock-subboard has no clock-signal input
2.normal(2) - indicates that the clock-signal input status of the clock-subboard is normal
3.fault(3) - indicates that the clock-signal input status of the clock-subboard is faulty
4.no3rdclksubboard(255) - indicates that there is no 3rd subboard
"
::= { hwSystemClockManagePara 4 }
-- 1.3.6.1.4.1.2011.6.25.1.3.5
hw3rdClkSubBoardOutputStatus OBJECT-TYPE
SYNTAX INTEGER
{
normal(1),
fault(2),
no3rdclksubboard(255)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Clock-subboard clock output status.
Options:
1.normal(1) - indicates that the clock-subboard output status is normal
2.fault(2) - indicates thaclock-subboard output status is faulty
3.no3rdclksubboard(255) - indicates that there is no 3rd subboard
"
::= { hwSystemClockManagePara 5 }
-- 1.3.6.1.4.1.2011.6.25.1.3.6
hwClockSelectionMode OBJECT-TYPE
SYNTAX INTEGER
{
qlDisable(1),
qlEnable(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Clock selection mode.
Options:
1.qlDisable(1) - indicates that a clock source is selected based on its priority
2.qlEnable(2) - indicates that a clock source is selected based on its quality
"
::= { hwSystemClockManagePara 6 }
-- 1.3.6.1.4.1.2011.6.25.1.3.8
hwClkRevertiveMode OBJECT-TYPE
SYNTAX INTEGER
{
revertive(1),
nonRevertive(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Clock revertive mode.
Options:
1.revertive(1) - Though a clock source had fault record,
it still can be selected as the system clock
2.nonRevertive(2)- If one clock source had fault record, it can't
be selected as system clock
"
::= { hwSystemClockManagePara 8 }
-- 1.3.6.1.4.1.2011.6.25.1.3.9
hw1588ClkType OBJECT-TYPE
SYNTAX INTEGER
{
oc(1),
bc(2),
tc(3),
tcoc(4),
tcbc(5),
tbc(6),
invalid(255)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The 1588 clock type of device.
Options:
1. oc(1) - indicates that 1588 clock type is Ordinary Clock
2. bc(2) - indicates that 1588 clock type is Boundary Clock
3. tc(3) - indicates that 1588 clock type is Transparent Clock
4. tcoc(4) - indicates that 1588 clock type is combination of
transparent clock and ordinary clock
5. tcbc(5) - indicates that 1588 clock type is combination of
transparent clock and boundary Clock
6. tbc(6) - indicates that 1588 clock type is Telecommunication Boundary Clock
7. invalid(255) - indicates that the 1588 clock type is not available
"
::= { hwSystemClockManagePara 9 }
-- 1.3.6.1.4.1.2011.6.25.1.3.10
hw1588ClkPEmode OBJECT-TYPE
SYNTAX INTEGER
{
p2p(1),
e2e(2),
invalid(255)
}
MAX-ACCESS read-write
STATUS obsolete
DESCRIPTION
"The 1588 clock PE-mode of device.
Options:
1. p2p(1) - indicates that the 1588 clock works in P2P mode
2. e2e(2) - indicates that the 1588 clock works at E2E mode
3. invalid(255) - indicates that the 1588 clock PE-mode is not available
"
::= { hwSystemClockManagePara 10 }
-- 1.3.6.1.4.1.2011.6.25.1.3.11
hw1588ClkID OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (16))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The 1588 clock identity of device.
The first 4 bytes must be 0x259e40 for an OLT.
The first 4 bytes must be 0x259e41 for a MxU."
::= { hwSystemClockManagePara 11 }
-- 1.3.6.1.4.1.2011.6.25.1.3.12
hwExtClkoutputThresholdSsmQl OBJECT-TYPE
SYNTAX INTEGER
{
qlPRC(2),
qlSsuA(4),
qlSsuB(8),
qlSEC(11),
qlDNU(15)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Clock source quality level.
Options:
1. qlPRC(2) - primary reference clock
2. qlSsuA(4) - indicates that the clock signal comes from class I or class V
sub-clock stipulated in G.812 protocol
3. qlSsuB(8) - indicates that the clock signal comes from class VI sub-clock
stipulated in G.812 protocol
4. qlSEC(11) - indicates that The clock signal comes from SEC(SDH Equipment Clock)
stipulated in G.813 protocol
5. qlDNU(15) - indicates that the clock signal can't be used for synchronization
"
::= { hwSystemClockManagePara 12 }
-- 1.3.6.1.4.1.2011.6.25.1.3.13
hwExtClkOutputMode OBJECT-TYPE
SYNTAX INTEGER
{
fixTrace(1),
autoTrace(2),
noTrace(3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The mode of external clock output.
Options:
1.fixTrace(1) -Output system clock
2.autoTrace(2) -indicates that external clock output automatically
3.noTrace(3) -indicates that that the external clock output is closed
"
::= { hwSystemClockManagePara 13 }
-- 1.3.6.1.4.1.2011.6.25.1.3.14
hwClkWaitRestoreTime OBJECT-TYPE
SYNTAX Integer32 (0..12)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"If the clock state changes from failed to normal, wait
the specified time to join clock source selection.
Defined in G.781: wait restore time.
Unit:minute
Default value: 5 minutes
Range: 0 - 12
"
::= { hwSystemClockManagePara 14 }
-- 1.3.6.1.4.1.2011.6.25.1.3.15
hwClkHoldoffTime OBJECT-TYPE
SYNTAX Integer32 (0..1)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"If the clock state changes from normal to failed, wait the specified time to mark the failed state.
Unit:second.
Default value: 0 second
Range: 0 - 1
0 - 0 second
1 - 1 second
"
::= { hwSystemClockManagePara 15 }
-- 1.3.6.1.4.1.2011.6.25.1.3.16
hwQlOutputUpperLimit OBJECT-TYPE
SYNTAX INTEGER
{
qlPRC(2),
qlSsuA(4),
qlSsuB(8),
qlSEC(11),
qlDNU(15)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"System output clock signal with a lower quality than the limited value.
Options:
1.qlPRC(2) - indicates that the quality of the system output clock signal is lower than qlPRC
2.qlSsuA(4) - indicates that the quality of the system output clock signal is lower than qlSsuA
3.qlSsuB(8) - indicates that the quality of the system output clock signal is lower than qlSsuB
4.qlSEC(11) - indicates that the quality of the system output clock signal is lower than qlSEC
5.qlDNU(15) - indicates that the quality of the system output clock signal is lower than qlDNU
"
::= { hwSystemClockManagePara 16 }
-- 1.3.6.1.4.1.2011.6.25.1.3.17
hwPTPEnable OBJECT-TYPE
SYNTAX INTEGER
{
enable(1),
disable(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enable or disable the 1588 function.
Options:
1.enable(1) - Enable the 1588 function
2.disable(2) - Disable the 1588 function
Default: disable(2)
"
::= { hwSystemClockManagePara 17 }
-- 1.3.6.1.4.1.2011.6.25.1.3.18
hwExtClkOutputBitsType OBJECT-TYPE
SYNTAX INTEGER
{
bitsType2MHz(1),
bitsType2Mbps(2),
bitsType1544bps(3),
bitsType1ppsInput(4),
bitsType1ppsOutput(5)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Get or set output signal of GPIO board. Default to bitsType2Mbps(2).
Options:
1. bitsType2MHz (1) - indicates that the output signal of the GPIO board is bitsType2MHz
2. bitsType2Mbps(2) - indicates that the output signal of the GPIO board is bitsType2Mbps
3. bitsType1544bps(3) - indicates that the output signal of the GPIO board is bitsType1.544Mbps
4. bitsType1ppsInput(4) - indicates that the input signal of the GPIO board is bitsType1ppsInput
5. bitsType1ppsOutput(5) - indicates that the output signal of the GPIO board is bitsType1ppsOutput
"
::= { hwSystemClockManagePara 18 }
-- 1.3.6.1.4.1.2011.6.25.1.3.19
hwQlInputLowerLimit OBJECT-TYPE
SYNTAX INTEGER
{
qlPRC(2),
qlSsuA(4),
qlSsuB(8),
qlSEC(11)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Clock source quality level:
Options:
1. qlPRC(2) - indicates that primary reference clock
2. qlSsuA(4) - indicates that the clock signal comes from class I or class
V sub-clock prescribed on G.812 protocol
3. qlSsuB(8) - indicates that the clock signal comes from class VI sub-clock
prescribed on G.812 protocol
4. qlSEC(11) - indicates that the clock signal comes from SEC(SDH Equipment
Clock) prescribed on G.813 protocol
"
::= { hwSystemClockManagePara 19 }
-- 1.3.6.1.4.1.2011.6.25.1.3.20
hwPtpDomain OBJECT-TYPE
SYNTAX Integer32 (0..255)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"PTP domain value.
BC:
Range: 0-255
Default: 0
T-BC:
Range: 24-43
Default: 24
"
::= { hwSystemClockManagePara 20 }
-- 1.3.6.1.4.1.2011.6.25.1.3.21
hwPtpBMCEnable OBJECT-TYPE
SYNTAX INTEGER
{
enable(1),
disable(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"PTP BMC switch.
BC:
Options:
1. enable(1) - indicates that ptp BMC is enabled
2. disable(2) - indicates that ptp BMC is disabled
Default: disable(2)
T-BC:
enable(1) - indicates that ptp BMC is enabled
"
::= { hwSystemClockManagePara 21 }
-- 1.3.6.1.4.1.2011.6.25.1.3.22
hwPtpLockState OBJECT-TYPE
SYNTAX INTEGER
{
locked(1),
unlocked(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"PTP lock state.
Options:
1. locked(1) - indicates that the clock is locked
2. unlocked(2) - indicates that the clock is unlocked
"
::= { hwSystemClockManagePara 22 }
-- 1.3.6.1.4.1.2011.6.25.1.3.23
hwPtpFreqLockStatus OBJECT-TYPE
SYNTAX INTEGER
{
locked(1),
unlocked(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"PTP frequency lock state.
Options:
1. locked(1) - indicates that the frequency is locked
2. unlocked(2) - indicates that the frequency is unlocked
"
::= { hwSystemClockManagePara 23 }
-- 1.3.6.1.4.1.2011.6.25.1.3.24
hwPtpTimeScale OBJECT-TYPE
SYNTAX INTEGER
{
ptp(1),
arb(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The time scale of the grandmaster clock.
"
::= { hwSystemClockManagePara 24 }
-- 1.3.6.1.4.1.2011.6.25.1.3.25
hwPtpFrequencyTraceable OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value is true if the frequency determinning the timescale is traceable to a primary reference, otherwise the value is false.
"
::= { hwSystemClockManagePara 25 }
-- 1.3.6.1.4.1.2011.6.25.1.3.26
hwPtpTimeTraceable OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value is ture if the time is traceable to a primary reference. otherwise the value is false.
"
::= { hwSystemClockManagePara 26 }
-- 1.3.6.1.4.1.2011.6.25.1.3.27
hwPtpGMClockID OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (16))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Grand master clock ID.
"
::= { hwSystemClockManagePara 27 }
-- 1.3.6.1.4.1.2011.6.25.1.3.28
hwPtpGrandMasterClockPriority1 OBJECT-TYPE
SYNTAX Integer32 (0..255)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Grand master clock priority1.
"
::= { hwSystemClockManagePara 28 }
-- 1.3.6.1.4.1.2011.6.25.1.3.29
hwPtpGrandMasterClockPriority2 OBJECT-TYPE
SYNTAX Integer32 (0..255)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Grand master clock priority2.
"
::= { hwSystemClockManagePara 29 }
-- 1.3.6.1.4.1.2011.6.25.1.3.30
hwPtpGrandMasterClockAccuracy OBJECT-TYPE
SYNTAX Integer32 (0..255)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Grand master clock accuracy.
"
::= { hwSystemClockManagePara 30 }
-- 1.3.6.1.4.1.2011.6.25.1.3.31
hwPtpGrandMasterClockClass OBJECT-TYPE
SYNTAX Integer32 (0..255)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Grand master clock class.
"
::= { hwSystemClockManagePara 31 }
-- 1.3.6.1.4.1.2011.6.25.1.3.32
hwPtpGrandMasterClockTimeSource OBJECT-TYPE
SYNTAX INTEGER
{
atomicclock(16),
gps(32),
terrestrialradio(48),
ptp(64),
ntp(80),
handset(96),
other(144),
internaloscillator(160)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the source of time used by the grandmaster clock.
"
::= { hwSystemClockManagePara 32 }
-- 1.3.6.1.4.1.2011.6.25.1.3.33
hwPtpPhyPhaseSubCur OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"PTP physics phase current warp.
"
::= { hwSystemClockManagePara 33 }
-- 1.3.6.1.4.1.2011.6.25.1.3.34
hwPtpPhyPhaseSubMin OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"PTP physics phase min warp.
"
::= { hwSystemClockManagePara 34 }
-- 1.3.6.1.4.1.2011.6.25.1.3.35
hwPtpPhyPhaseSubMax OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"PTP physics phase max warp.
"
::= { hwSystemClockManagePara 35 }
-- 1.3.6.1.4.1.2011.6.25.1.3.36
hwPtpPhyPhaseSubMean OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"PTP physics phase mean warp.
"
::= { hwSystemClockManagePara 36 }
-- 1.3.6.1.4.1.2011.6.25.1.3.37
hwPtpTimeSyncOffsetCur OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"PTP current time offset.
"
::= { hwSystemClockManagePara 37 }
-- 1.3.6.1.4.1.2011.6.25.1.3.38
hwPtpTimeSyncOffsetMin OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"PTP min time offset.
"
::= { hwSystemClockManagePara 38 }
-- 1.3.6.1.4.1.2011.6.25.1.3.39
hwPtpTimeSyncOffsetMax OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"PTP max time offset.
"
::= { hwSystemClockManagePara 39 }
-- 1.3.6.1.4.1.2011.6.25.1.3.40
hwPtpTimeSyncOffsetMean OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"PTP average time offset.
"
::= { hwSystemClockManagePara 40 }
-- 1.3.6.1.4.1.2011.6.25.1.3.41
hwPtpTimeMeanpathdelayCur OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"PTP current path delay.
"
::= { hwSystemClockManagePara 41 }
-- 1.3.6.1.4.1.2011.6.25.1.3.42
hwPtpTimeMeanpathdelayMin OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"PTP min path delay.
"
::= { hwSystemClockManagePara 42 }
-- 1.3.6.1.4.1.2011.6.25.1.3.43
hwPtpTimeMeanpathdelayMax OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"PTP max path delay.
"
::= { hwSystemClockManagePara 43 }
-- 1.3.6.1.4.1.2011.6.25.1.3.44
hwPtpTimeMeanpathdelayMean OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"PTP average path delay.
"
::= { hwSystemClockManagePara 44 }
-- 1.3.6.1.4.1.2011.6.25.1.3.45
hwPtpDlyMeasureEnable OBJECT-TYPE
SYNTAX INTEGER
{
enable(1),
disable(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"PTP asymmetry measure switch.
Options:
1. enable(1) - indicates that ptp asymmetry measure is enabled
2. disable(2) - indicates that ptp asymmetry measure is disabled
"
::= { hwSystemClockManagePara 45 }
-- 1.3.6.1.4.1.2011.6.25.1.3.46
hwPtpParentClockID OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (16))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"PTP parent clockID.
"
::= { hwSystemClockManagePara 46 }
-- 1.3.6.1.4.1.2011.6.25.1.3.47
hwPtpParentPortNumber OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"PTP parent portnumber."
::= { hwSystemClockManagePara 47 }
-- 1.3.6.1.4.1.2011.6.25.1.3.48
hwExtClkOutputState OBJECT-TYPE
SYNTAX INTEGER
{
on(1),
off(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"External clock output state.
Options:
1. on(1) - indicates that the output of external clock is opened
2. off(2) - indicates that the output of external clock is closed
"
::= { hwSystemClockManagePara 48 }
-- 1.3.6.1.4.1.2011.6.25.1.3.49
hwPtpLocalSourceLocalPriority OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"In T-BC mode, the local priority is configured to calculate the optimum master clock.
The smaller the value, the higher the priority.
Range: 1-255
Default: 128
This attribute is invalid in BC mode.
"
::= { hwSystemClockManagePara 49 }
-- 1.3.6.1.4.1.2011.6.25.1.3.50
hwPtpLocalSourcePriority2 OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"In T-BC mode, the priority2 is configured to calculate the optimum master clock.
The smaller the value, the higher the priority.
This attribute is invalid in BC mode.
Range: 0-255
Default: 128
"
::= { hwSystemClockManagePara 50 }
-- 1.3.6.1.4.1.2011.6.25.1.4
hwClockOutPortManageTable OBJECT-TYPE
SYNTAX SEQUENCE OF HwClockOutPortManageEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Clock output port management table.
This table is used to enable or disable the output
port and query the status of the output port. The index of this table is
hwClkOutputPostion, indicating the ifIndex of physical position of the clock source.
"
::= { hwClkMibObjects 4 }
-- 1.3.6.1.4.1.2011.6.25.1.4.1
hwClockOutPortManageEntry OBJECT-TYPE
SYNTAX HwClockOutPortManageEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Clock output port management table.
This table is used to enable or disable the output
port and query the status of the output port. The index of this entry is
hwClkOutputPostion, indicating the ifIndex of physical position of the clock source.
"
INDEX { hwClkOutputPostion }
::= { hwClockOutPortManageTable 1 }
HwClockOutPortManageEntry ::=
SEQUENCE {
hwClkOutputPostion
Integer32,
hwClkOutPortEnable
INTEGER,
hwSsmQlOutPortEnable
INTEGER
}
-- 1.3.6.1.4.1.2011.6.25.1.4.1.1
hwClkOutputPostion OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The index of physical position of the clock source.
The highest byte is useless.
The second byte describes the frame ID.
The third byte describes the slot ID.
The lowest byte describes the port ID.
The following shows how to use parameter during the get or set operation:
0x 00, FF,00,00 Frame ID; 0~255
0x 00, 00,FF,00 Slot ID; 0~255
0x 00, 00,00,FF Port ID; 0~255
"
::= { hwClockOutPortManageEntry 1 }
-- 1.3.6.1.4.1.2011.6.25.1.4.1.2
hwClkOutPortEnable OBJECT-TYPE
SYNTAX INTEGER
{
enable(0),
disable(1)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Clock output port switch.
Options:
1. enable(0) - indicates that clock source output of this BITS port is enabled
2. disable(1) - indicates that clock source output of this BITS port is disabled
"
::= { hwClockOutPortManageEntry 2 }
-- 1.3.6.1.4.1.2011.6.25.1.4.1.3
hwSsmQlOutPortEnable OBJECT-TYPE
SYNTAX INTEGER
{
enable(1),
disable(2)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"SSM QL output mode.
Options:
1.enable(1) - indicates that SSM QL output of the port is enabled
2.disable(2) - indicates that SSM QL output of the port is disabled
"
::= { hwClockOutPortManageEntry 3 }
-- 1.3.6.1.4.1.2011.6.25.1.5
hwClock1588ManageTable OBJECT-TYPE
SYNTAX SEQUENCE OF HwClock1588ManageEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Clock 1588 source management table. This table is used to manage
the 1588 clock source.
The index of this table is hw1588ClkInIndex, which is the ID of the 1588 clock source.
"
::= { hwClkMibObjects 5 }
-- 1.3.6.1.4.1.2011.6.25.1.5.1
hwClock1588ManageEntry OBJECT-TYPE
SYNTAX HwClock1588ManageEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Clock 1588 source management table. This table is used to manage
the 1588 clock source.
The index of this entry is hw1588ClkInIndex, which is the ID of the 1588 clock source.
"
INDEX { hw1588ClkInIndex }
::= { hwClock1588ManageTable 1 }
HwClock1588ManageEntry ::=
SEQUENCE {
hw1588ClkInIndex
Integer32,
hw1588ClkInPostion
Integer32,
hw1588ClkPriority
Integer32,
hw1588ClkInOperStatus
INTEGER,
hw1588ClkInRowStatus
RowStatus,
hw1588ClkReqSendTimeInterval
Integer32,
hw1588ClkDomainNumber
Integer32,
hw1588ClkPtpPEMode
INTEGER,
hw1588ClkPtpMsgFormat
INTEGER,
hw1588ClkPtpLineWarpMode
INTEGER,
hw1588ClkPtpLineWarpDirect
INTEGER,
hw1588ClkPtpLineWarpValue
Integer32,
hw1588ClkPtpTimeSourceID
OCTET STRING,
hw1588ClkPtpVlan
Integer32,
hw1588ClkPtpInfoMode
INTEGER,
hw1588ClkPtpAnnounceTimeout
Integer32,
hw1588ClkGMClockID
OCTET STRING,
hw1588ClkAnnounceSendTimeInterval
Integer32,
hw1588ClkSyncSendTimeInterval
Integer32,
hw1588ClkPtpLockState
INTEGER,
hw1588ClkInWorkMode
INTEGER,
hw1588ClkInSelectStatus
INTEGER
}
-- 1.3.6.1.4.1.2011.6.25.1.5.1.1
hw1588ClkInIndex OBJECT-TYPE
SYNTAX Integer32 (0..9)
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"Clock 1588 source index.
Range: 0-9"
::= { hwClock1588ManageEntry 1 }
-- 1.3.6.1.4.1.2011.6.25.1.5.1.2
hw1588ClkInPostion OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The index of physical position of clock 1588 source.
The highest byte is useless.
The second byte describes the frame ID.
The third byte describes the slot ID.
The lowest byte describes the port ID.
The following shows how to use parameters during the get or set operation:
0x00,FF,00,00 Frame ID; 0-255
0x00,00,FF,00 Slot ID; 0-255
0x00,00,00,FF Port ID; 0-255
"
::= { hwClock1588ManageEntry 2 }
-- 1.3.6.1.4.1.2011.6.25.1.5.1.3
hw1588ClkPriority OBJECT-TYPE
SYNTAX Integer32 (0..9 | 255)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Clock 1588 source priority.
The priority ranges from 0 to 9 in a descending order.If the value is 255 in the get operation,
it indicates that the priority of the ptp source isn't configured.
"
::= { hwClock1588ManageEntry 3 }
-- 1.3.6.1.4.1.2011.6.25.1.5.1.4
hw1588ClkInOperStatus OBJECT-TYPE
SYNTAX INTEGER
{
none(1),
normal(2),
failure(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Clock 1588 source status:
Options:
1.none(1) - indicates that the clock source index is not configured
2.normal(2) - indicates that the status of clock source is normal
3.failure(3)- indicates that the status of clock source is faulty
"
::= { hwClock1588ManageEntry 4 }
-- 1.3.6.1.4.1.2011.6.25.1.5.1.5
hw1588ClkInRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Clock 1588 source operation includes adding and deleting clock 1588 source.
If the value is set to 4, it indicates that a clock 1588 source is created.
If the value is set to 6, it indicates that an existing clock source is deleted.
"
::= { hwClock1588ManageEntry 5 }
-- 1.3.6.1.4.1.2011.6.25.1.5.1.6
hw1588ClkReqSendTimeInterval OBJECT-TYPE
SYNTAX Integer32 (1..21)
MAX-ACCESS read-create
STATUS obsolete
DESCRIPTION
"1588 Req send time interval.
Options:
1.1/1024s( 1) - indicates that the time interval is 1/1024s
2.1/512s( 2) - indicates that the time interval is 1/512s
3.1/256s( 3) - indicates that the time interval is 1/256s
4.1/128s( 4) - indicates that the time interval is 1/128s
5.1/64s( 5) - indicates that the time interval is 1/64s
6.1/32s( 6) - indicates that the time interval is 1/32s
7.1/16s( 7) - indicates that the time interval is 1/16s
8.1/8s( 8) - indicates that the time interval is 1/8s
9.1/4s( 9) - indicates that the time interval is 1/4s
10.1/2s(10) - indicates that the time interval is 1/2s
11.1s(11) - indicates that the time interval is 1s
12.2s(12) - indicates that the time interval is 2s
13.4s(13) - indicates that the time interval is 4s
14.8s(14) - indicates that the time interval is 8s
15.16s(15) - indicates that the time interval is 16s
16.32s(16) - indicates that the time interval is 32s
17.64s(17) - indicates that the time interval is 64s
18.128s(18) - indicates that the time interval is 128s
19.256s(19) - indicates that the time interval is 256s
20.512s(20) - indicates that the time interval is 512s
21.1024s(21) - indicates that the time interval is 1024s
"
::= { hwClock1588ManageEntry 6 }
-- 1.3.6.1.4.1.2011.6.25.1.5.1.7
hw1588ClkDomainNumber OBJECT-TYPE
SYNTAX Integer32 (0..255)
MAX-ACCESS read-create
STATUS obsolete
DESCRIPTION
"1588 clock domain number:
Range: 0-255
Default: 0
"
::= { hwClock1588ManageEntry 7 }
-- 1.3.6.1.4.1.2011.6.25.1.5.1.8
hw1588ClkPtpPEMode OBJECT-TYPE
SYNTAX INTEGER
{
p2p(1),
e2e(2)
}
MAX-ACCESS read-create
STATUS obsolete
DESCRIPTION
"PTP MODE,default value is e2e(2).
Options:
1. p2p(1) - indicates that the 1588 clock Ptp Pe Mode is p2p
2. e2e(2) - indicates that the 1588 clock Ptp Pe Mode is e2e
"
::= { hwClock1588ManageEntry 8 }
-- 1.3.6.1.4.1.2011.6.25.1.5.1.9
hw1588ClkPtpMsgFormat OBJECT-TYPE
SYNTAX INTEGER
{
ptpeth(1),
ptpip(2)
}
MAX-ACCESS read-create
STATUS obsolete
DESCRIPTION
"PTP message encapsulation format,the default value is PTPETH(1).
Options:
1. ptpeth(1) - indicates that the PTP message is encapsulated into an Ethernet packet
2. ptpip(2) - indicates that the PTP message is encapsulated into an IP packet
"
::= { hwClock1588ManageEntry 9 }
-- 1.3.6.1.4.1.2011.6.25.1.5.1.10
hw1588ClkPtpLineWarpMode OBJECT-TYPE
SYNTAX INTEGER
{
length(1),
time(2)
}
MAX-ACCESS read-create
STATUS obsolete
DESCRIPTION
"PTP line warp mode, the default value is length(1).
Options:
1. length(1) - indicates that the warp is represented by length
2. time(2) - indicates that the warp is represented by time
"
::= { hwClock1588ManageEntry 10 }
-- 1.3.6.1.4.1.2011.6.25.1.5.1.11
hw1588ClkPtpLineWarpDirect OBJECT-TYPE
SYNTAX INTEGER
{
positive(1),
negative(2)
}
MAX-ACCESS read-create
STATUS obsolete
DESCRIPTION
"PTP line warp direct, the default value is positive(1).
Options:
1. positive(1) - indicates that the warp is in the positive direction
2. negative(2) - indicates that the warp is in the negative direction
"
::= { hwClock1588ManageEntry 11 }
-- 1.3.6.1.4.1.2011.6.25.1.5.1.12
hw1588ClkPtpLineWarpValue OBJECT-TYPE
SYNTAX Integer32 (0..65529)
MAX-ACCESS read-create
STATUS obsolete
DESCRIPTION
"PTP Line Warp Value:
IF warp mode is length(1), the range is 0~14562m.
If warp mode is time(2), the range is 0~65529 ns.
"
::= { hwClock1588ManageEntry 12 }
-- 1.3.6.1.4.1.2011.6.25.1.5.1.13
hw1588ClkPtpTimeSourceID OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (20))
MAX-ACCESS read-create
STATUS obsolete
DESCRIPTION
"PTP source port ID:
It is 10 bytes in length and the default value is 0.
"
::= { hwClock1588ManageEntry 13 }
-- 1.3.6.1.4.1.2011.6.25.1.5.1.14
hw1588ClkPtpVlan OBJECT-TYPE
SYNTAX Integer32 (0..4094)
MAX-ACCESS read-create
STATUS obsolete
DESCRIPTION
"PTP Vlan:
Range: 0-4094.
Default: 1.
"
::= { hwClock1588ManageEntry 14 }
-- 1.3.6.1.4.1.2011.6.25.1.5.1.15
hw1588ClkPtpInfoMode OBJECT-TYPE
SYNTAX INTEGER
{
muticast(1),
unicast(2)
}
MAX-ACCESS read-create
STATUS obsolete
DESCRIPTION
"PTP info mode,default value is multicast(1).
Options:
1. multicast(1) - indicates that the PTP info mode is multicast.
2. unicast(2) - indicates that the PTP info mode is unicast.
"
::= { hwClock1588ManageEntry 15 }
-- 1.3.6.1.4.1.2011.6.25.1.5.1.16
hw1588ClkPtpAnnounceTimeout OBJECT-TYPE
SYNTAX Integer32 (2..1048576)
MAX-ACCESS read-create
STATUS obsolete
DESCRIPTION
"Announce timeout:
Range: 1-1048576 ms
Range: 1 - 1048576
Default: 128 ms
"
::= { hwClock1588ManageEntry 16 }
-- 1.3.6.1.4.1.2011.6.25.1.5.1.17
hw1588ClkGMClockID OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (16))
MAX-ACCESS read-only
STATUS obsolete
DESCRIPTION
"Grandmaster clock ID."
::= { hwClock1588ManageEntry 17 }
-- 1.3.6.1.4.1.2011.6.25.1.5.1.18
hw1588ClkAnnounceSendTimeInterval OBJECT-TYPE
SYNTAX Integer32 (1..21)
MAX-ACCESS read-create
STATUS obsolete
DESCRIPTION
"1588 announce send time interval,the default value is 1/8s(8).
Options:
1. 1/1024s(1) - indicates that the time interval is 1/1024s
2. 1/512s (2) - indicates that the time interval is 1/512s
3. 1/256s (3) - indicates that the time interval is 1/256s
4. 1/128s (4) - indicates that the time interval is 1/128s
5. 1/64s (5) - indicates that the time interval is 1/64s
6. 1/32s (6) - indicates that the time interval is 1/32s
7. 1/16s (7) - indicates that the time interval is 1/16s
8. 1/8s (8) - indicates that the time interval is 1/8s
9. 1/4s (9) - indicates that the time interval is 1/4s
10. 1/2s (10) - indicates that the time interval is 1/2s
11. 1s (11) - indicates that the time interval is 1s
12. 2s (12) - indicates that the time interval is 2s
13. 4s (13) - indicates that the time interval is 4s
14. 8s (14) - indicates that the time interval is 8s
15. 16s (15) - indicates that the time interval is 16s
16. 32s (16) - indicates that the time interval is 32s
17. 64s (17) - indicates that the time interval is 64s
18. 128s (18) - indicates that the time interval is 128s
19. 256s (19) - indicates that the time interval is 256s
20. 512s (20) - indicates that the time interval is 512s
21. 1024s (21) - indicates that the time interval is 1024s
"
::= { hwClock1588ManageEntry 18 }
-- 1.3.6.1.4.1.2011.6.25.1.5.1.19
hw1588ClkSyncSendTimeInterval OBJECT-TYPE
SYNTAX Integer32 (1..21)
MAX-ACCESS read-create
STATUS obsolete
DESCRIPTION
"1588 sync send time interval,the default value is 1/8s(8).
Options:
1. 1/1024s(1) - indicates that the time interval is 1/1024s
2. 1/512s (2) - indicates that the time interval is 1/512s
3. 1/256s (3) - indicates that the time interval is 1/256s
4. 1/128s (4) - indicates that the time interval is 1/128s
5. 1/64s (5) - indicates that the time interval is 1/64s
6. 1/32s (6) - indicates that the time interval is 1/32s
7. 1/16s (7) - indicates that the time interval is 1/16s
8. 1/8s (8) - indicates that the time interval is 1/8s
9. 1/4s (9) - indicates that the time interval is 1/4s
10. 1/2s (10) - indicates that the time interval is 1/2s
11. 1s (11) - indicates that the time interval is 1s
12. 2s (12) - indicates that the time interval is 2s
13. 4s (13) - indicates that the time interval is 4s
14. 8s (14) - indicates that the time interval is 8s
15. 16s (15) - indicates that the time interval is 16s
16. 32s (16) - indicates that the time interval is 32s
17. 64s (17) - indicates that the time interval is 64s
18. 128s (18) - indicates that the time interval is 128s
19. 256s (19) - indicates that the time interval is 256s
20. 512s (20) - indicates that the time interval is 512s
21. 1024s (21) - indicates that the time interval is 1024s
"
::= { hwClock1588ManageEntry 19 }
-- 1.3.6.1.4.1.2011.6.25.1.5.1.20
hw1588ClkPtpLockState OBJECT-TYPE
SYNTAX INTEGER
{
locked(1),
unlocked(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"1588 port lock state.
Options:
1. locked(1) - indicates that the clock is locked
2. unlocked(2) - indicates that the clock is unlocked
"
::= { hwClock1588ManageEntry 20 }
-- 1.3.6.1.4.1.2011.6.25.1.5.1.21
hw1588ClkInWorkMode OBJECT-TYPE
SYNTAX INTEGER
{
ptp(1),
bits(2)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Time source type.
Options:
1. ptp(1) - indicates that time source that need to specify frame/slot/port
2. bits(2) - indicates that time source of a BITS port
"
::= { hwClock1588ManageEntry 21 }
-- 1.3.6.1.4.1.2011.6.25.1.5.1.22
hw1588ClkInSelectStatus OBJECT-TYPE
SYNTAX INTEGER
{
yes(1),
no(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Time source select status.
Options:
1. yes(1) - indicates that the time source is selected as the current time source.
2. no(2) - indicates that the time source isn't selected as the current time source.
"
::= { hwClock1588ManageEntry 22 }
-- 1.3.6.1.4.1.2011.6.25.1.6
hwClockTransManageTable OBJECT-TYPE
SYNTAX SEQUENCE OF HwClockTransManageEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Clock transaction management table.
This table is used to configure and query the clock transmission.
The index of this table is hwClkTransID, which is also the ID of
the clock transmission.
"
::= { hwClkMibObjects 6 }
-- 1.3.6.1.4.1.2011.6.25.1.6.1
hwClockTransManageEntry OBJECT-TYPE
SYNTAX HwClockTransManageEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Clock transaction management table.
This table is used to configure and query the clock transmission.
The index of this entry is hwClkTransID, which is also the ID of
the clock transmission.
"
INDEX { hwClkTransID }
::= { hwClockTransManageTable 1 }
HwClockTransManageEntry ::=
SEQUENCE {
hwClkTransID
Integer32,
hwClkLocalIP
IpAddress,
hwClkVlanTag
Integer32,
hwClkRemoteIP
IpAddress,
hwClkRowStatus
RowStatus
}
-- 1.3.6.1.4.1.2011.6.25.1.6.1.1
hwClkTransID OBJECT-TYPE
SYNTAX Integer32 (1..32)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Clock transaction ID: The range is from 1 to 32.
Range: 1 - 32
"
::= { hwClockTransManageEntry 1 }
-- 1.3.6.1.4.1.2011.6.25.1.6.1.2
hwClkLocalIP OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"IP address of a local device"
::= { hwClockTransManageEntry 2 }
-- 1.3.6.1.4.1.2011.6.25.1.6.1.3
hwClkVlanTag OBJECT-TYPE
SYNTAX Integer32 (0..4095)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"VLAN tag.
If the value is 0, it indicates that there is no VLAN tag in clock packages.
Range: 0 - 4095
"
::= { hwClockTransManageEntry 3 }
-- 1.3.6.1.4.1.2011.6.25.1.6.1.4
hwClkRemoteIP OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"IP address of remote device"
::= { hwClockTransManageEntry 4 }
-- 1.3.6.1.4.1.2011.6.25.1.6.1.5
hwClkRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Clock transaction operation. If the value is set to 4, it indicates that
a clock transmission configuration is added. If the value is set to 6,
it indicates that an existing clock transmission configuration is deleted.
"
::= { hwClockTransManageEntry 5 }
-- 1.3.6.1.4.1.2011.6.25.1.7
hwClockTransIDNext OBJECT-TYPE
SYNTAX Integer32 (0..32)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
" Clock transaction index that host returns.
If the value is 0, it indicates that there is no free index.
Range: 0 - 32
"
::= { hwClkMibObjects 7 }
-- 1.3.6.1.4.1.2011.6.25.1.8
hwACMClockIPTable OBJECT-TYPE
SYNTAX SEQUENCE OF HwACMClockIPEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Clock ACM source IP table.
The index of this table is ifIndex which comes from
ifTable. The method for using ifIndex is provided in ifIndex's mib description.
"
::= { hwClkMibObjects 8 }
-- 1.3.6.1.4.1.2011.6.25.1.8.1
hwACMClockIPEntry OBJECT-TYPE
SYNTAX HwACMClockIPEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Clock ACM source IP table.
The index of this entry is ifIndex which comes from
ifTable. The method for using ifIndex is provided in ifIndex's mib description.
"
INDEX { hwACMClockIPIndex }
::= { hwACMClockIPTable 1 }
HwACMClockIPEntry ::=
SEQUENCE {
hwACMClockIPIndex
Integer32,
hwACMClockIP
Integer32,
hwACMClkPostion
Integer32,
hwACMClockIPRowStatus
INTEGER
}
-- 1.3.6.1.4.1.2011.6.25.1.8.1.1
hwACMClockIPIndex OBJECT-TYPE
SYNTAX Integer32 (0..2147483647)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Currently, it supports only ACM IP address but it can be extended in the future.
Range: 0 - 2147483647
"
::= { hwACMClockIPEntry 1 }
-- 1.3.6.1.4.1.2011.6.25.1.8.1.2
hwACMClockIP OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
" ACM cLOCK switch IP address at layer 3.
Range: 0.0.0.0-255.255.255.255
"
::= { hwACMClockIPEntry 2 }
-- 1.3.6.1.4.1.2011.6.25.1.8.1.3
hwACMClkPostion OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Physical position of clock source ACM IP address.
The highest byte is useless. The second byte describes the frame ID,
The third byte describes the slot ID.
The lowest byte is useless.
The following shows how to use parameter during the get or set operation.
0x 0000, FFFF,0000,0000 Frame ID; 0-255
0x 0000, 0000,FFFF,0000 Slot ID; 0-255.
"
::= { hwACMClockIPEntry 3 }
-- 1.3.6.1.4.1.2011.6.25.1.8.1.4
hwACMClockIPRowStatus OBJECT-TYPE
SYNTAX INTEGER
{
createAndGo(4),
destroy(6)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Rowstatus of the ACM clock IP address.
Options:
1. createAndGo(4) - Creates an ACM clock IP address
2. destroy(6) - Destroys an ACM clock IP address.
"
::= { hwACMClockIPEntry 4 }
-- 1.3.6.1.4.1.2011.6.25.1.9
hwBitsPortManageTable OBJECT-TYPE
SYNTAX SEQUENCE OF HwBitsPortManageEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Time management table.
The index of this table is ifIndex which comes from
ifTable. The method for using ifIndex is provided in ifIndex's mib description.
"
::= { hwClkMibObjects 9 }
-- 1.3.6.1.4.1.2011.6.25.1.9.1
hwBitsPortManageEntry OBJECT-TYPE
SYNTAX HwBitsPortManageEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Time management table.
The index of this entry is ifIndex which comes from
ifTable. The method for using ifIndex is provided in ifIndex's mib description.
"
INDEX { ifIndex }
::= { hwBitsPortManageTable 1 }
HwBitsPortManageEntry ::=
SEQUENCE {
hwBitsPortClkWorkMode
INTEGER,
hwBitsPortTimeWorkMode
INTEGER,
hwBitsPortIOStatus
INTEGER,
hwPtpBitsClockAccuracy
Integer32,
hwPtpBitsClockClass
Integer32,
hwPtpBitsPriority1
Integer32,
hwPtpBitsPriority2
Integer32,
hwPtpBitsTimeSource
INTEGER,
hwBits1ppsDelayDirection
INTEGER,
hwBits1ppsDelayValue
Integer32,
hwPtpBitsPortLocalPriority
Integer32,
hwPtpBitsOffsetScaledLogVariance
Integer32
}
-- 1.3.6.1.4.1.2011.6.25.1.9.1.1
hwBitsPortClkWorkMode OBJECT-TYPE
SYNTAX INTEGER
{
e1(1),
t1(2),
f2mhz(3),
invalid(255)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Port work mode of BITS clock.
Options:
1. e1(1) - indicates that E1 type of clock input/output.
2. t1(2) - indicates that T1 type of clock input/output
3. f2mhz(3) - indicates that 2MHz type of clock input/output
4. invalid(255) - indicates that it is not configured
"
::= { hwBitsPortManageEntry 1 }
-- 1.3.6.1.4.1.2011.6.25.1.9.1.2
hwBitsPortTimeWorkMode OBJECT-TYPE
SYNTAX INTEGER
{
ppsubx(1),
dcls(2),
invalid(255),
ppsnmea(3)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Time work mode of Bits clock.
Options:
1.ppsubx(1) - indicates that 1pps+ubx type of time input/output
2.dcls(2) - indicates that DCLS type of time input/output
3.invalid(255) - indicates that it is not configured
4.ppsnmea(3) - indicates that 1pps+nmea type of time input/output
"
::= { hwBitsPortManageEntry 2 }
-- 1.3.6.1.4.1.2011.6.25.1.9.1.3
hwBitsPortIOStatus OBJECT-TYPE
SYNTAX INTEGER
{
input(1),
output(2),
invalid(255)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Time interface direction mode.
Options:
1.input(1) - indicates that the mode of time interface is input
2.output(2) - indicates that the mode of time interface source is output
3.invalid(255) - indicates that time input/output isn't configured
"
::= { hwBitsPortManageEntry 3 }
-- 1.3.6.1.4.1.2011.6.25.1.9.1.4
hwPtpBitsClockAccuracy OBJECT-TYPE
SYNTAX Integer32 (0..255)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The clockAccuracy characterizes a clock for the purpose of the best master clock (BMC) algorithm. The value of
this attribute shall be estimated by the clock to a precision consistent with the value of the selected enumeration.
BC:
Range: 0x0-0xFF
01 0x20 - indicates that the time is accurate to within 25 ns
02 0x21 - indicates that the time is accurate to within 100 ns
03 0x22 - indicates that the time is accurate to within 250 ns
04 0x23 - indicates that the time is accurate to within 1 us
05 0x24 - indicates that the time is accurate to within 2.5 us
06 0x25 - indicates that the time is accurate to within 10 us
07 0x26 - indicates that the time is accurate to within 25 us
08 0x27 - indicates that the time is accurate to within 100 us
09 0x28 - indicates that the time is accurate to within 250 us
10 0x29 - indicates that the time is accurate to within 1 ms
11 0x2A - indicates that the time is accurate to within 2.5 ms
12 0x2B - indicates that the time is accurate to within 10 ms
13 0x2C - indicates that the time is accurate to within 25 ms
14 0x2D - indicates that the time is accurate to within 100 ms
15 0x2E - indicates that the time is accurate to within 250 ms
16 0x2F - indicates that the time is accurate to within 1 s
17 0x30 - indicates that the time is accurate to within 10 s
18 0x31 - indicates that the time is accurate to >10 s
19 0x80-0xFD - indicates that for use by alternate PTP profiles
Default: 0x20
T-BC:
Options:
01 0xFE - indicates that the time accuracy is unknown
02 0x21 - indicates that the time is accurate to within 100 ns
Default: 0xFE
"
::= { hwBitsPortManageEntry 4 }
-- 1.3.6.1.4.1.2011.6.25.1.9.1.5
hwPtpBitsClockClass OBJECT-TYPE
SYNTAX Integer32 (0..255)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The clockClass attribute of an ordinary or boundary clock denotes the traceability of the time or frequency
distributed by the grandmaster clock.
BC:
Range: 0-255
1. 6 - indicates that shall designate a clock that is synchronized to a primary reference time source. The timescale distributed shall
be PTP. A clockClass 6 clock shall not be a slave to another clock in the domain
2. 7 - indicates that shall designate a clock that has previously been designated as clockClass 6 but that has lost the ability to
synchronize to a primary reference time source and is in holdover mode and within holdover specifications. The timescale
distributed shall be PTP. A clockClass 7 clock shall not be a slave to another clock in the domain
3. 13 - indicates that shall designate a clock that is synchronized to an application-specific source of time. The timescale
distributed shall be ARB. A clockClass 13 clock shall not be a slave to another clock in the domain
4. 14 - indicates that shall designate a clock that has previously been designated as clockClass 13 but that has lost the ability to
synchronize to an application-specific source of time and is in holdover mode and within holdover specifications.
The timescale distributed shall be ARB. A clockClass 14 clock shall not be a slave to another clock in the domain
5. 52 - indicates that degradation alternative A for a clock of clockClass 7 that is not within holdover specification. A clock of
clockClass 52 shall not be a slave to another clock in the domain
6. 58 - indicates that degradation alternative A for a clock of clockClass 14 that is not within holdover specification. A clock of
clockClass 58 shall not be a slave to another clock in the domain
7. 187 - indicates that degradation alternative B for a clock of clockClass 7 that is not within holdover specification. A clock of
clockClass 187 may be a slave to another clock in the domain
8. 193 - indicates that degradation alternative B for a clock of clockClass 14 that is not within holdover specification. A clock of
clockClass 193 may be a slave to another clock in the domain
9. 248 - indicates that default. This clockClass shall be used if none of the other clockClass definitions apply
10. 255 - indicates that shall be the clockClass of a slave-only clock
Default: 6
T-BC:
Range: 0-255
1. 6 - T-GM connected to a PRTC in locked mode
2. 7 - T-GM in holdover, within holdover specification, traceable or non-traceable to Category 1 frequency source
3. 135 - T-BC in holdover, within holdover specification, traceable or non-traceable to Category 1 frequency source
4. 140 - T-GM in holdover, out of holdover specification, traceable to Category 1 frequency source
5. 150 - T-GM in holdover, out of holdover specification, traceable to Category 2 frequency source
6. 160 - T-GM in holdover, out of holdover specification, traceable to Category 3 frequency source
7. 165 - T-BC in holdover, out of holdover specification
8. 248 - T-GM or T-BC without time reference since start-up
9. 255 - Slave only OC(does not send Announce messages)
Default: 6
"
::= { hwBitsPortManageEntry 5 }
-- 1.3.6.1.4.1.2011.6.25.1.9.1.6
hwPtpBitsPriority1 OBJECT-TYPE
SYNTAX Integer32 (0..255)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The attribute priority1 is used in the execution of the best master clock algorithm. Lower values take precedence.
Range: 0-255
Default: 128
This attribute is invalid in T-BC mode.
"
::= { hwBitsPortManageEntry 6 }
-- 1.3.6.1.4.1.2011.6.25.1.9.1.7
hwPtpBitsPriority2 OBJECT-TYPE
SYNTAX Integer32 (0..255)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The attribute priority2 is used in the execution of the best master clock algorithm. Lower values take precedence.
Range: 0-255
Default: 128
"
::= { hwBitsPortManageEntry 7 }
-- 1.3.6.1.4.1.2011.6.25.1.9.1.8
hwPtpBitsTimeSource OBJECT-TYPE
SYNTAX INTEGER
{
atomicClock(16),
gPS(32),
terrestrialRadio(48),
ptp(64),
ntp(80),
handSet(96),
other(144),
internalOscillator(160)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This attribute indicates the source of time used by the grandmaster clock.
Options:
1.atomicClock(16) - indicates that any device, or device directly connected to such a device,
that is based on atomic resonance for frequency and that has been calibrated
against international standards for frequency and, if the PTP timescale is used.
2.gPS(32) - indicates that any device synchronized to a satellite system that distribute time
and frequency tied to international standards
3.terrestrialRadio(48) - indicates that any device synchronized via any of the radio distribution systems
that distribute time and frequency tied to international standards
4.ptp(64) - indicates that any device synchronized to a PTP-based source of time external to the domain
5.ntp(80) - indicates that any device synchronized via NTP or Simple Network Time Protocol (SNTP) to servers
that distribute time and frequency tied to international standards
6.handSet(96) - indicates that used for any device whose time has been set by means of a human interface
based on observation of an international standards source of time to within the claimed clock accuracy
7.other(144) - indicates that other source of time and/or frequency not covered by other values
8.internalOscillator(160)- indicates that any device whose frequency is not based on atomic resonance nor calibrated against international
standards for frequency, and whose time is based on a free-running oscillator with epoch determined in an
arbitrary or unknown manner
Default: gPS(32)
"
::= { hwBitsPortManageEntry 8 }
-- 1.3.6.1.4.1.2011.6.25.1.9.1.9
hwBits1ppsDelayDirection OBJECT-TYPE
SYNTAX INTEGER
{
receive(1),
send(2)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Delay mode of the time signal on the BITS port.
Options:
1.receive(1) - indicates that delay mode is receive
2.send(2) - indicates that delay mode is send
"
::= { hwBitsPortManageEntry 9 }
-- 1.3.6.1.4.1.2011.6.25.1.9.1.10
hwBits1ppsDelayValue OBJECT-TYPE
SYNTAX Integer32 (0..200000)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Adjusted delay of the time signal on the BITS port. In receive mode, it ranges from 0 to 200000.
In send mode, it ranges from 0 to 1600.
Unit:ns
Default: 0
"
::= { hwBitsPortManageEntry 10 }
-- 1.3.6.1.4.1.2011.6.25.1.9.1.11
hwPtpBitsPortLocalPriority OBJECT-TYPE
SYNTAX Integer32 (1..255)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"In T-BC mode, the local priority of the BITS port is configured to calculate the optimum master clock.
The smaller the value, the higher the priority.
Range: 1-255
Default value: 128
This attribute is invalid in BC mode.
"
::= { hwBitsPortManageEntry 11 }
-- 1.3.6.1.4.1.2011.6.25.1.9.1.12
hwPtpBitsOffsetScaledLogVariance OBJECT-TYPE
SYNTAX Integer32 (-1 | 0..65535)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Indicates estimate of the variations of the local clock from a linear timescale.
In T-BC mode, it can only be 0x4E5D (default) and 0xFFFF.
This attribute is invalid in BC mode.
"
::= { hwBitsPortManageEntry 12 }
-- 1.3.6.1.4.1.2011.6.25.1.10
hw1588ClkPtpPortManageTable OBJECT-TYPE
SYNTAX SEQUENCE OF Hw1588ClkPtpPortManageEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"1588 clock PTP port management table.
The index of this table is ifIndex which comes from ifTable.
The method for using ifIndex is provided in ifIndex's mib description.
"
::= { hwClkMibObjects 10 }
-- 1.3.6.1.4.1.2011.6.25.1.10.1
hw1588ClkPtpPortManageEntry OBJECT-TYPE
SYNTAX Hw1588ClkPtpPortManageEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"1588 clock PTP port management table.
The index of this entry is ifIndex which comes from ifTable.
The method for using ifIndex is provided in ifIndex's mib description.
"
INDEX { ifIndex }
::= { hw1588ClkPtpPortManageTable 1 }
Hw1588ClkPtpPortManageEntry ::=
SEQUENCE {
hw1588ClkPtpPortState
INTEGER,
hw1588ClkPtpPortEnable
INTEGER,
hw1588ClkPtpPortVlan
Integer32,
hw1588ClkPtpPortSourceIp
IpAddress,
hw1588ClkPtpPortMsgFormat
INTEGER,
hw1588ClkPtpPortInfoMode
INTEGER,
hw1588ClkPtpPortAnnounceSendTimeInterval
Integer32,
hw1588ClkPtpPortSyncSendTimeInterval
Integer32,
hw1588ClkPtpPortReqSendTimeInterval
Integer32,
hw1588ClkPtpPortLineWarpMode
INTEGER,
hw1588ClkPtpPortLineWarpDirect
INTEGER,
hw1588ClkPtpPortLineWarpValue
Integer32,
hw1588ClkPtpPortAnnounceTimeout
Integer32,
hw1588ClkPtpPortDomainNum
Integer32,
hw1588ClkDSCP
Integer32,
hw1588ClkVlanPRI
Integer32,
hw1588ClkPtpPortDelayMechanism
INTEGER,
hw1588ClkPtpPortMacDestinationMac
MacAddress,
hw1588ClkPtpPortUdpDestinationMac
MacAddress,
hw1588ClkPtpPortUdpEgressSourceIp
IpAddress,
hw1588ClkPtpPortUdpEgressDestinationIp
IpAddress,
hw1588ClkPtpPortUdpVlanPRI
Integer32,
hw1588ClkPtpPortMacVlanPRI
Integer32,
hw1588ClkPtpPortUdpEgressDscp
Integer32,
hw1588ClkPtpPortClockStep
INTEGER,
hw1588ClkPtpPortUdpVlan
Integer32,
hw1588ClkPtpPortMacVlan
Integer32,
hwPtpPortRingFiberLengthChangeValue
Integer32,
hwPtpPortRingFiberLengthChangeValueFlag
INTEGER,
hw1588ClkPtpPortNotSlave
INTEGER,
hw1588ClkPtpPortLocalPriority
Integer32
}
-- 1.3.6.1.4.1.2011.6.25.1.10.1.1
hw1588ClkPtpPortState OBJECT-TYPE
SYNTAX INTEGER
{
initializing(1),
faulty(2),
disabled(3),
listening(4),
premaster(5),
master(6),
passive(7),
uncalibrated(8),
slave(9),
invalid(255)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"1588 port status.
Options:
1.initializing(1) - indicates that the state of 1588 clock PTP port is initializing
2.faulty(2) - indicates that the state of 1588 clock PTP port is faulty
3.disabled(3) - indicates that the state of 1588 clock PTP port is disabled
4.listening(4) - indicates that the state of 1588 clock PTP port is listening
5.premaster(5) - indicates that the state of 1588 clock PTP port is premaster
6.master(6) - indicates that the state of 1588 clock PTP port is master
7.passive(7) - indicates that the state of 1588 clock PTP port is passive
8.uncalibrated(8) - indicates that the state of 1588 clock PTP port is uncalibrated
9.slave(9) - indicates that the state of 1588 clock PTP port is slave
10.invalid(255) - indicates that the state of 1588 clock PTP port is invalid
"
::= { hw1588ClkPtpPortManageEntry 1 }
-- 1.3.6.1.4.1.2011.6.25.1.10.1.2
hw1588ClkPtpPortEnable OBJECT-TYPE
SYNTAX INTEGER
{
enable(1),
disable(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enable or disable the 1588 function of PTP port.
Options:
1. enable(1) -Enable the 1588 function of this port
2. disable(2) -Disable the 1588 function of this port
Default: disable(2)
"
::= { hw1588ClkPtpPortManageEntry 2 }
-- 1.3.6.1.4.1.2011.6.25.1.10.1.3
hw1588ClkPtpPortVlan OBJECT-TYPE
SYNTAX Integer32 (0..4094)
MAX-ACCESS read-write
STATUS obsolete
DESCRIPTION
"PTP VLAN.
Range: 0 - 4094
"
::= { hw1588ClkPtpPortManageEntry 3 }
-- 1.3.6.1.4.1.2011.6.25.1.10.1.4
hw1588ClkPtpPortSourceIp OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS obsolete
DESCRIPTION
"PTP port source IP address"
::= { hw1588ClkPtpPortManageEntry 4 }
-- 1.3.6.1.4.1.2011.6.25.1.10.1.5
hw1588ClkPtpPortMsgFormat OBJECT-TYPE
SYNTAX INTEGER
{
ptpeth(1),
ptpip(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"PTP message encapsulation format,the default value is PTPETH(1).
Options:
1. ptpeth(1) - indicates that the PTP message is encapsulated into an Ethernet packet
2. ptpip(2) - indicates that the PTP message is encapsulated into an IP packet
"
::= { hw1588ClkPtpPortManageEntry 5 }
-- 1.3.6.1.4.1.2011.6.25.1.10.1.6
hw1588ClkPtpPortInfoMode OBJECT-TYPE
SYNTAX INTEGER
{
multicast(1),
unicast(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"PTP info mode.
Default: multicast(1)
Options:
1. multicast(1) - indicates that the Info mode of the 1588 clock PTP port is multicast
2. unicast(2) - indicates that the Info mode of the 1588 clock PTP port is unicast
"
::= { hw1588ClkPtpPortManageEntry 6 }
-- 1.3.6.1.4.1.2011.6.25.1.10.1.7
hw1588ClkPtpPortAnnounceSendTimeInterval OBJECT-TYPE
SYNTAX Integer32 (6..14)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Interval for sending announce packets.
BC:
Default: 1/8s(7)
Options:
1. 1/16s (6) - indicates that the time interval is 1/16s
2. 1/8s (7) - indicates that the time interval is 1/8s
3. 1/4s (8) - indicates that the time interval is 1/4s
4. 1/2s (9) - indicates that the time interval is 1/2s
5. 1s (10) - indicates that the time interval is 1s
6. 2s (11) - indicates that the time interval is 2s
7. 4s (12) - indicates that the time interval is 4s
8. 8s (13) - indicates that the time interval is 8s
9. 16s (14) - indicates that the time interval is 16s
T-BC:
1/8s (7) - indicates that the time interval is 1/8s
"
::= { hw1588ClkPtpPortManageEntry 7 }
-- 1.3.6.1.4.1.2011.6.25.1.10.1.8
hw1588ClkPtpPortSyncSendTimeInterval OBJECT-TYPE
SYNTAX Integer32 (2..11)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Interval for sending sync packets.
BC:
Default: 1/16s(6)
Options:
1. 1/256s (2) - indicates that the time interval is 1/256s
2. 1/128s (3) - indicates that the time interval is 1/128s
3. 1/64s (4) - indicates that the time interval is 1/64s
4. 1/32s (5) - indicates that the time interval is 1/32s
5. 1/16s (6) - indicates that the time interval is 1/16s
6. 1/8s (7) - indicates that the time interval is 1/8s
7. 1/4s (8) - indicates that the time interval is 1/4s
8. 1/2s (9) - indicates that the time interval is 1/24s
9. 1s (10) - indicates that the time interval is 1s
10.2s (11) - indicates that the time interval is 2s
T-BC:
1/16s (6) - indicates that the time interval is 1/16s
"
::= { hw1588ClkPtpPortManageEntry 8 }
-- 1.3.6.1.4.1.2011.6.25.1.10.1.9
hw1588ClkPtpPortReqSendTimeInterval OBJECT-TYPE
SYNTAX Integer32 (6..14)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Interval for sending req packets.
BC:
Default: 1/8s(7)
Options:
1. 1/16s (6) - indicates that the time interval is 1/16s
3. 1/8s (7) - indicates that the time interval is 1/8s
3. 1/4s (8) - indicates that the time interval is 1/4s
4. 1/2s (9) - indicates that the time interval is 1/2s
5. 1s (10) - indicates that the time interval is 1s
6. 2s (11) - indicates that the time interval is 2s
7. 4s (12) - indicates that the time interval is 4s
8. 8s (13) - indicates that the time interval is 8s
9. 16s (14) - indicates that the time interval is 16s
T-BC:
1/16s (6) - indicates that the time interval is 1/16s
"
::= { hw1588ClkPtpPortManageEntry 9 }
-- 1.3.6.1.4.1.2011.6.25.1.10.1.10
hw1588ClkPtpPortLineWarpMode OBJECT-TYPE
SYNTAX INTEGER
{
length(1),
time(2)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Type of the asymmetric transmission windage for optical
fibers, the default value is length(1).
Options:
1. length(1) - indicates that the warp is represented by length
2. time(2) - indicates that the warp is represented by time
"
::= { hw1588ClkPtpPortManageEntry 10 }
-- 1.3.6.1.4.1.2011.6.25.1.10.1.11
hw1588ClkPtpPortLineWarpDirect OBJECT-TYPE
SYNTAX INTEGER
{
positive(1),
negative(2)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Fiber windage direction, the default value is positive(1).
Options:
1. positive(1) - indicates that the warp is in the positive direction
2. negative(2) - indicates that the warp is in the negative direction
"
::= { hw1588ClkPtpPortManageEntry 11 }
-- 1.3.6.1.4.1.2011.6.25.1.10.1.12
hw1588ClkPtpPortLineWarpValue OBJECT-TYPE
SYNTAX Integer32 (0..65529)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"PTP line warp value.
If warp mode is length(1), the range is 0~14562m.
If warp mode is time(2) the range is 0~65529 ns.
"
::= { hw1588ClkPtpPortManageEntry 12 }
-- 1.3.6.1.4.1.2011.6.25.1.10.1.13
hw1588ClkPtpPortAnnounceTimeout OBJECT-TYPE
SYNTAX Integer32 (2..255)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Announce timeout specifies that the interval for receiving announce packets on the port.
BC:
Range: 2 - 255
Default value: 3
T-BC:
Range: 3 - 255
Default value: 3
"
::= { hw1588ClkPtpPortManageEntry 13 }
-- 1.3.6.1.4.1.2011.6.25.1.10.1.14
hw1588ClkPtpPortDomainNum OBJECT-TYPE
SYNTAX Integer32 (0..255)
MAX-ACCESS read-create
STATUS obsolete
DESCRIPTION
"1588 clock domain number.
Range: 0-255
Default value: 0
"
::= { hw1588ClkPtpPortManageEntry 14 }
-- 1.3.6.1.4.1.2011.6.25.1.10.1.15
hw1588ClkDSCP OBJECT-TYPE
SYNTAX Integer32 (0..63)
MAX-ACCESS read-create
STATUS obsolete
DESCRIPTION
"1588 clock DSCP:0-63."
::= { hw1588ClkPtpPortManageEntry 15 }
-- 1.3.6.1.4.1.2011.6.25.1.10.1.16
hw1588ClkVlanPRI OBJECT-TYPE
SYNTAX Integer32 (0..7)
MAX-ACCESS read-create
STATUS obsolete
DESCRIPTION
"1588 clock Vlan priority:0-7."
::= { hw1588ClkPtpPortManageEntry 16 }
-- 1.3.6.1.4.1.2011.6.25.1.10.1.17
hw1588ClkPtpPortDelayMechanism OBJECT-TYPE
SYNTAX INTEGER
{
delayMechanism(1),
pdelayMechanism(2)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Delay measurement mechanism.
BC:
Options:
1.delayMechanism(1) - indicates that delay mechanism is delay-mechanism.
2.pdelayMechanism(2) - indicates that delay mechanism is pdelay-mechanism.
Default: delayMechanism(1)
T-BC:
delayMechanism(1) - indicates that delay mechanism is delay-mechanism.
"
::= { hw1588ClkPtpPortManageEntry 17 }
-- 1.3.6.1.4.1.2011.6.25.1.10.1.18
hw1588ClkPtpPortMacDestinationMac OBJECT-TYPE
SYNTAX MacAddress
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Destination MAC address of MAC-encapsulated packets.
BC:
When the delay measurement mechanism is delay, the default destination MAC address is 011b-1900-0000.
When the delay measurement mechanism is pdelay, the default destination MAC address is 0180-c200-000e.
T-BC:
Supports only MAC-encapsulated packets and supports multicast MAC address configuration.
It can be 01-80-C2-00-00-0E and 01-1B-19-00-00-00 (default).
"
::= { hw1588ClkPtpPortManageEntry 18 }
-- 1.3.6.1.4.1.2011.6.25.1.10.1.19
hw1588ClkPtpPortUdpDestinationMac OBJECT-TYPE
SYNTAX MacAddress
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Destination MAC address of UDP-encapsulated packets.
When the delay measurement mechanism is delay, the default destination MAC address is 0100-5e00-0181.
When the delay measurement mechanism is pdelay, the default destination MAC address is 0100-5e00-006b.
This attribute is invalid in T-BC mode.
"
::= { hw1588ClkPtpPortManageEntry 19 }
-- 1.3.6.1.4.1.2011.6.25.1.10.1.20
hw1588ClkPtpPortUdpEgressSourceIp OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Source IP address of UDP-encapsulated packets.
Default:0.0.0.0
This attribute is invalid in T-BC mode.
"
::= { hw1588ClkPtpPortManageEntry 20 }
-- 1.3.6.1.4.1.2011.6.25.1.10.1.21
hw1588ClkPtpPortUdpEgressDestinationIp OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Destination IP address of UDP-encapsulated packets.
When the delay measurement mechanism is delay, the default destination IP address is 224.0.1.129.
When the delay measurement mechanism is pdelay, the default destination IP address is 224.0.0.107.
This attribute is invalid in T-BC mode.
"
::= { hw1588ClkPtpPortManageEntry 21 }
-- 1.3.6.1.4.1.2011.6.25.1.10.1.22
hw1588ClkPtpPortUdpVlanPRI OBJECT-TYPE
SYNTAX Integer32 ( -1 | 0..7)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"VLAN priority of UDP-encapsulated packets.
Default:7
Invalid(-1)
This attribute is invalid in T-BC mode.
"
::= { hw1588ClkPtpPortManageEntry 22 }
-- 1.3.6.1.4.1.2011.6.25.1.10.1.23
hw1588ClkPtpPortMacVlanPRI OBJECT-TYPE
SYNTAX Integer32 (-1 | 0..7)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"VLAN priority of MAC-encapsulated packets.
Default:7
Invalid(-1)
This attribute is invalid in T-BC mode.
"
::= { hw1588ClkPtpPortManageEntry 23 }
-- 1.3.6.1.4.1.2011.6.25.1.10.1.24
hw1588ClkPtpPortUdpEgressDscp OBJECT-TYPE
SYNTAX Integer32 (-1 | 0..63 )
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"DSCP of UDP-encapsulated packets.
Default:56
Invalid(-1)
This attribute is invalid in T-BC mode.
"
::= { hw1588ClkPtpPortManageEntry 24 }
-- 1.3.6.1.4.1.2011.6.25.1.10.1.25
hw1588ClkPtpPortClockStep OBJECT-TYPE
SYNTAX INTEGER
{
oneStep(1),
twoStep(2)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Clock step mode.
Options:
1.oneStep(1) - indicates that clock step mode is one-step.
2.twoStep(2) - indicates that clock step mode is two-step.
Default: oneStep(1)
"
::= { hw1588ClkPtpPortManageEntry 25 }
-- 1.3.6.1.4.1.2011.6.25.1.10.1.26
hw1588ClkPtpPortUdpVlan OBJECT-TYPE
SYNTAX Integer32 ( -1 | 0 |1..4094)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"VLAN of UDP-encapsulated packets.
Default: untag(0)
Invalid(-1)
This attribute is invalid in T-BC mode.
"
::= { hw1588ClkPtpPortManageEntry 26 }
-- 1.3.6.1.4.1.2011.6.25.1.10.1.27
hw1588ClkPtpPortMacVlan OBJECT-TYPE
SYNTAX Integer32 ( -1 | 0 | 1..4094)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"VLAN of MAC-encapsulated packets.
BC:
Default: untag(0)
Invalid(-1)
T-BC:
Supports only untag(0).
"
::= { hw1588ClkPtpPortManageEntry 27 }
-- 1.3.6.1.4.1.2011.6.25.1.10.1.28
hwPtpPortRingFiberLengthChangeValue OBJECT-TYPE
SYNTAX Integer32 ( -1 | 0..65529 )
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The change (unit: ns) of the fiber length in a ring network detection. It may be a positive or negative value, which depends on the next node.
If the value is -1, the ring network detection function does not take effect. "
::= { hw1588ClkPtpPortManageEntry 28 }
-- 1.3.6.1.4.1.2011.6.25.1.10.1.29
hwPtpPortRingFiberLengthChangeValueFlag OBJECT-TYPE
SYNTAX INTEGER
{
invalid(-1),
negative(1),
positive(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Flag of the change of the fiber length in a ring network detection.
Options:
1.invalid(-1) - indicates that the the ring network detection function does not take effect.
2.negative(1) - indicates that the change of the fiber length is a negative value.
3.positive(2) - indicates that the change of the fiber length is a positive value.
"
::= { hw1588ClkPtpPortManageEntry 29 }
-- 1.3.6.1.4.1.2011.6.25.1.10.1.30
hw1588ClkPtpPortNotSlave OBJECT-TYPE
SYNTAX INTEGER
{
enable(1),
disable(2),
invalid(255)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"In T-BC mode, this port cannot be the slave port when notSlave is enable;
this port can be the slave port when notSlave is disable.
By default, it is enable(1).
This attribute is invalid in BC mode.
"
::= { hw1588ClkPtpPortManageEntry 30 }
-- 1.3.6.1.4.1.2011.6.25.1.10.1.31
hw1588ClkPtpPortLocalPriority OBJECT-TYPE
SYNTAX Integer32 ( -1 | 1..255)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"In T-BC mode, the local priority of the port is configured to calculate the optimum master clock.
The smaller the value, the higher the priority.
Range: 1-255
Default value: 128
This attribute is invalid in BC mode.
Invalid value: -1
"
::= { hw1588ClkPtpPortManageEntry 31 }
-- 1.3.6.1.4.1.2011.6.25.1.11
hwClkTraps OBJECT IDENTIFIER ::= { hwClkMibObjects 11 }
-- 1.3.6.1.4.1.2011.6.25.1.11.1
hwClkTrapVbOids OBJECT IDENTIFIER ::= { hwClkTraps 1 }
-- 1.3.6.1.4.1.2011.6.25.1.11.1.1
hwClkGMClockIdChangeTrapSn OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"SN of traps for reporting that the 1588 GM clock identity changes."
::= { hwClkTrapVbOids 1 }
-- 1.3.6.1.4.1.2011.6.25.1.11.1.2
hwClkTimeSrcIdChangeTrapSn OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"SN of traps for reporting that the 1588 time source port identity changes."
::= { hwClkTrapVbOids 2 }
-- 1.3.6.1.4.1.2011.6.25.1.11.1.3
hw3rdClkOldSubBoardWorkMode OBJECT-TYPE
SYNTAX INTEGER
{
trace(1),
keep(2),
thirdsurge(3),
snap(4),
no3rdclksubboard(255)
}
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"The Out work mode of 3rd sub-board clock,the enumerative value is the same
with hw3rdClkSubBoardWorkMode.
Options:
1. trace(1) - indicates that the clock is working in tracing mode
2. keep(2) - indicates that the clock is working in keeping mode
3. thirdsurge(3) - indicates that the clock is working in 3rd subboard crystal
4. snap(4) - indicates clock is working in snap mode
5. no3rdclksubboard(255) - indicates that there is no 3rd subboard
"
::= { hwClkTrapVbOids 3 }
-- 1.3.6.1.4.1.2011.6.25.1.11.1.4
hwClkOutTypeTrapSn OBJECT-TYPE
SYNTAX INTEGER
{
sdh(1),
tdm(2),
system(3),
clk19M(4),
systemObsolete(5),
external(6),
external1(7)
}
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"Clock out type.
Currently, there are seven types: SDH, TDM, system, 19 MHzm, systemObsolete, external and external1.
Options:
1.sdh(1) - indicates that output clock type is SDH
2.tdm(2) - indicates that output clock type is TDM
3.system(3) - indicates that output clock type is system
4.clk19M(4) - indicates that output clock type is clk19M
5.systemObsolete(5) - indicates that output clock type is systemObsolete
6.external(6) - indicates that output clock type is external
7.external1(7) - indicates that output clock type is external1
"
::= { hwClkTrapVbOids 4 }
-- 1.3.6.1.4.1.2011.6.25.1.11.1.5
hw1588ACRPdvState OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (16))
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"1588ACR PDV state.
Options:
1.Normal - indicates that the 1588ACR PDV state is normal
2.LimitExceeded - indicates that the 1588ACR PDV state is limit exceeded
"
::= { hwClkTrapVbOids 5 }
-- 1.3.6.1.4.1.2011.6.25.1.11.1.6
hwPtpaServerID OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"1588ACR server ID."
::= { hwClkTrapVbOids 6 }
-- 1.3.6.1.4.1.2011.6.25.1.11.2
hwClkCommonTraps OBJECT IDENTIFIER ::= { hwClkTraps 2 }
-- 1.3.6.1.4.1.2011.6.25.1.11.2.1
hwClkCommonTrapsPrefix OBJECT IDENTIFIER ::= { hwClkCommonTraps 1 }
-- 1.3.6.1.4.1.2011.6.25.1.11.2.1.1
hwClkGmcclockIdChangeTrap NOTIFICATION-TYPE
OBJECTS { hwConfigChangeIP, hw1588ClkInIndex, hwPtpGMClockID }
STATUS current
DESCRIPTION
"This trap generates when the identity of the 1588 GM clock changes."
::= { hwClkCommonTrapsPrefix 1 }
-- 1.3.6.1.4.1.2011.6.25.1.11.2.1.2
hwClkTimeSourcePortIdentityTrap NOTIFICATION-TYPE
OBJECTS { hwConfigChangeIP, hw1588ClkInIndex, hwPtpParentClockID, hwPtpParentPortNumber }
STATUS current
DESCRIPTION
"This trap generates when the identity of the 1588 time source port changes."
::= { hwClkCommonTrapsPrefix 2 }
-- 1.3.6.1.4.1.2011.6.25.1.11.3
hwClkAlarmTraps OBJECT IDENTIFIER ::= { hwClkTraps 3 }
-- 1.3.6.1.4.1.2011.6.25.1.11.3.0
hwClkAlarmTrapsPrefix OBJECT IDENTIFIER ::= { hwClkAlarmTraps 0 }
-- 1.3.6.1.4.1.2011.6.25.1.11.3.0.1
hwClksystemclocksourceswitchesTrap NOTIFICATION-TYPE
OBJECTS { hwFrameIndex, hwSlotIndex, hwClkInIndex, hwClkInIndex }
STATUS current
DESCRIPTION
"This trap generates when the system clock source switches to a new one."
::= { hwClkAlarmTrapsPrefix 1 }
-- 1.3.6.1.4.1.2011.6.25.1.11.3.0.2
hwClkExternalInputSignalLoseTrap NOTIFICATION-TYPE
OBJECTS { hwFrameIndex, hwSlotIndex, hwClkInIndex }
STATUS current
DESCRIPTION
"This trap generates when the input signal of the external clock source was lost."
::= { hwClkAlarmTrapsPrefix 2 }
-- 1.3.6.1.4.1.2011.6.25.1.11.3.0.3
hwClkExternalInputSignalRecoversTrap NOTIFICATION-TYPE
OBJECTS { hwFrameIndex, hwSlotIndex, hwClkInIndex }
STATUS current
DESCRIPTION
"This trap generates when the input signal of the external clock source recovers."
::= { hwClkAlarmTrapsPrefix 3 }
-- 1.3.6.1.4.1.2011.6.25.1.11.3.0.4
hwClk1588ClockSrcSwitchTrap NOTIFICATION-TYPE
OBJECTS { hwFrameIndex, hwSlotIndex, hwClkInIndex, hwClkInIndex }
STATUS current
DESCRIPTION
"This trap generates when the 1588 clock source switches to a new one."
::= { hwClkAlarmTrapsPrefix 4 }
-- 1.3.6.1.4.1.2011.6.25.1.11.3.0.5
hwClk1588ClockSrcLostTrap NOTIFICATION-TYPE
OBJECTS { hwFrameIndex, hwSlotIndex, hwClkInIndex }
STATUS current
DESCRIPTION
"This trap generates when the 1588 clock source was lost."
::= { hwClkAlarmTrapsPrefix 5 }
-- 1.3.6.1.4.1.2011.6.25.1.11.3.0.6
hwClk1588ClockSrcRecoversTrap NOTIFICATION-TYPE
OBJECTS { hwFrameIndex, hwSlotIndex, hwClkInIndex }
STATUS current
DESCRIPTION
"This trap generates when the 1588 clock source recovers."
::= { hwClkAlarmTrapsPrefix 6 }
-- 1.3.6.1.4.1.2011.6.25.1.11.3.0.7
hwClkSubcardWorkmodeSwitchesTrap NOTIFICATION-TYPE
OBJECTS { hwFrameIndex, hwSlotIndex, hwSubslotIndex, hw3rdClkOldSubBoardWorkMode, hw3rdClkSubBoardWorkMode
}
STATUS current
DESCRIPTION
"This trap generates when the working mode of the clock sub-board has changed."
::= { hwClkAlarmTrapsPrefix 7 }
-- 1.3.6.1.4.1.2011.6.25.1.11.3.0.8
hwClkNoTraceTrap NOTIFICATION-TYPE
OBJECTS { hwClkOutTypeTrapSn }
STATUS current
DESCRIPTION
"This trap generates when the working mode of the clock sub-board has changed to non-tracing mode."
::= { hwClkAlarmTrapsPrefix 8 }
-- 1.3.6.1.4.1.2011.6.25.1.11.3.0.9
hwClkNoTraceRecoversTrap NOTIFICATION-TYPE
OBJECTS { hwClkOutTypeTrapSn }
STATUS current
DESCRIPTION
"This trap generates when the working mode of the clock sub-board has changed to tracing mode."
::= { hwClkAlarmTrapsPrefix 9 }
-- 1.3.6.1.4.1.2011.6.25.1.11.3.0.10
hwClkEsmcLoseTrap NOTIFICATION-TYPE
OBJECTS { hwFrameIndex, hwSlotIndex, hwClkInIndex }
STATUS current
DESCRIPTION
"This trap generates when ESMC is lost."
::= { hwClkAlarmTrapsPrefix 10 }
-- 1.3.6.1.4.1.2011.6.25.1.11.3.0.11
hwClkEsmcRestoreTrap NOTIFICATION-TYPE
OBJECTS { hwFrameIndex, hwSlotIndex, hwClkInIndex }
STATUS current
DESCRIPTION
"This trap generates when loss of ESMC recovers."
::= { hwClkAlarmTrapsPrefix 11 }
-- 1.3.6.1.4.1.2011.6.25.1.11.3.0.12
hwClkQlChangeTrap NOTIFICATION-TYPE
OBJECTS { hwFrameIndex, hwSlotIndex, hwClkInIndex, hwClkInQL, hwClkInQL,
hwClkInQL }
STATUS current
DESCRIPTION
"This trap generates when the input QL of clock source changes."
::= { hwClkAlarmTrapsPrefix 12 }
-- 1.3.6.1.4.1.2011.6.25.1.11.3.0.13
hwClkPtpLockFailTrap NOTIFICATION-TYPE
OBJECTS { hw1588ClkInIndex }
STATUS current
DESCRIPTION
"This trap generates when the lock state of ptp fail."
::= { hwClkAlarmTrapsPrefix 13 }
-- 1.3.6.1.4.1.2011.6.25.1.11.3.0.14
hwClkPtpLockRecoverTrap NOTIFICATION-TYPE
OBJECTS { hw1588ClkInIndex }
STATUS current
DESCRIPTION
"This trap generates when the lock state of ptp recover."
::= { hwClkAlarmTrapsPrefix 14 }
-- 1.3.6.1.4.1.2011.6.25.1.11.3.0.15
hwClkPtpAsymMeasureFailTrap NOTIFICATION-TYPE
OBJECTS { hwFrameIndex, hwSlotIndex, hwPortIndex, hwPtpTimeMeanpathdelayCur }
STATUS current
DESCRIPTION
"This trap generates when the result of asymmetry measure time offset is large than 55 ns."
::= { hwClkAlarmTrapsPrefix 15 }
-- 1.3.6.1.4.1.2011.6.25.1.11.3.0.16
hwClkPtpAsymMeasureRestoreTrap NOTIFICATION-TYPE
OBJECTS { hwFrameIndex, hwSlotIndex, hwPortIndex, hwPtpTimeMeanpathdelayCur }
STATUS current
DESCRIPTION
"This trap generates when the asymmetry measure time offset is small than 55 ns."
::= { hwClkAlarmTrapsPrefix 16 }
-- 1.3.6.1.4.1.2011.6.25.1.11.3.0.17
hwClkQlFailTrap NOTIFICATION-TYPE
OBJECTS { hwFrameIndex, hwSlotIndex, hwPortIndex, hwClkInQL, hwClkInQL }
STATUS current
DESCRIPTION
"This trap generates when the input QL of clock source less than the lower-limit."
::= { hwClkAlarmTrapsPrefix 17 }
-- 1.3.6.1.4.1.2011.6.25.1.11.3.0.18
hwClkQlRestoreTrap NOTIFICATION-TYPE
OBJECTS { hwFrameIndex, hwSlotIndex, hwPortIndex, hwClkInQL, hwClkInQL }
STATUS current
DESCRIPTION
"This trap generates when the input QL of clock source recovers."
::= { hwClkAlarmTrapsPrefix 18 }
-- 1.3.6.1.4.1.2011.6.25.1.11.3.0.19
hwClkOutExternalClosedTrap NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"This trap generates when the output of external clock is closed"
::= { hwClkAlarmTrapsPrefix 19 }
-- 1.3.6.1.4.1.2011.6.25.1.11.3.0.20
hwClkOutExternalOpenedTrap NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"This trap generates when the output of external clock is opened."
::= { hwClkAlarmTrapsPrefix 20 }
-- 1.3.6.1.4.1.2011.6.25.1.11.3.0.21
hwClkSysClockLockFailTrap NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"This trap generates when the lock state of system clock fail."
::= { hwClkAlarmTrapsPrefix 21 }
-- 1.3.6.1.4.1.2011.6.25.1.11.3.0.22
hwClkSysClockLockRecoverTrap NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"This trap generates when the lock state of system clock recover."
::= { hwClkAlarmTrapsPrefix 22 }
-- 1.3.6.1.4.1.2011.6.25.1.11.3.0.23
hwClkPdvStateChangeTrap NOTIFICATION-TYPE
OBJECTS { hw1588ACRPdvState }
STATUS current
DESCRIPTION
"The 1588ACR PDV state is changed."
::= { hwClkAlarmTrapsPrefix 23 }
-- 1.3.6.1.4.1.2011.6.25.1.11.3.0.24
hwClkPtpaTraceSourceChangeTrap NOTIFICATION-TYPE
OBJECTS { hwPtpaServerID, hwPtpaServerID }
STATUS current
DESCRIPTION
"The server source synchronized by the client is changed."
::= { hwClkAlarmTrapsPrefix 24 }
-- 1.3.6.1.4.1.2011.6.25.1.12
hw1588ACR OBJECT IDENTIFIER ::= { hwClkMibObjects 12 }
-- 1.3.6.1.4.1.2011.6.25.1.12.1
hw1588ACRMasterTable OBJECT-TYPE
SYNTAX SEQUENCE OF Hw1588ACRMasterEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"1588 ACR clock manage table.
The index of this table is master index.
"
::= { hw1588ACR 1 }
-- 1.3.6.1.4.1.2011.6.25.1.12.1.1
hw1588ACRMasterEntry OBJECT-TYPE
SYNTAX Hw1588ACRMasterEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"1588 ACR clock manage table.
The index of this entry is master index.
"
INDEX { hw1588ACRMasterIndex }
::= { hw1588ACRMasterTable 1 }
Hw1588ACRMasterEntry ::=
SEQUENCE {
hw1588ACRMasterIndex
Integer32,
hw1588ACRMasterIPAddr
IpAddress,
hw1588ACRMasterNegotiate
INTEGER,
hw1588ACRRowStatus
RowStatus
}
-- 1.3.6.1.4.1.2011.6.25.1.12.1.1.1
hw1588ACRMasterIndex OBJECT-TYPE
SYNTAX Integer32 (1..2)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Index of 1588 ACR master.
Range: 1 - 2
"
::= { hw1588ACRMasterEntry 1 }
-- 1.3.6.1.4.1.2011.6.25.1.12.1.1.2
hw1588ACRMasterIPAddr OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"1588 ACR master IP address"
::= { hw1588ACRMasterEntry 2 }
-- 1.3.6.1.4.1.2011.6.25.1.12.1.1.3
hw1588ACRMasterNegotiate OBJECT-TYPE
SYNTAX INTEGER
{
idle(1),
negotiate(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Port enabled type.
Options:
1. idle(1) - the negotiate state is idle
2. negotiate(2)- the negotiate state is negotiate
"
::= { hw1588ACRMasterEntry 3 }
-- 1.3.6.1.4.1.2011.6.25.1.12.1.1.4
hw1588ACRRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Row status"
::= { hw1588ACRMasterEntry 4 }
-- 1.3.6.1.4.1.2011.6.25.1.12.2
hw1588ACRManage OBJECT IDENTIFIER ::= { hw1588ACR 2 }
-- 1.3.6.1.4.1.2011.6.25.1.12.2.1
hw1588ACRNegotiateState OBJECT-TYPE
SYNTAX INTEGER
{
negotiateOn(1),
negotiateOff(2)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The 1588 ACR negotiate state.
Options:
1. negotiateOn(1) - start negotiate
2. negotiateOff(2) - stop negotiating
"
::= { hw1588ACRManage 1 }
-- 1.3.6.1.4.1.2011.6.25.1.12.2.2
hw1588ACRDomain OBJECT-TYPE
SYNTAX Integer32 (0..255)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The domain.
Range: 0-255
Default: 0
"
::= { hw1588ACRManage 2 }
-- 1.3.6.1.4.1.2011.6.25.1.12.2.3
hw1588ACRAnnounceTimeout OBJECT-TYPE
SYNTAX Integer32 (2..255)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The timeout times of rx announce packet.
Range: 2-255
Default: 3
"
::= { hw1588ACRManage 3 }
-- 1.3.6.1.4.1.2011.6.25.1.12.2.4
hw1588ACRMsgFormat OBJECT-TYPE
SYNTAX INTEGER
{
ptpeth(1),
ptpip(2)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"PTPACR message encapsulation format,the default value is ptpeth(1).
Options:
1. ptpeth(1) - indicates that the PTPACR message is encapsulated into an Ethernet packet
2. ptpip(2) - indicates that the PTPACR message is encapsulated into an IP packet
"
::= { hw1588ACRManage 4 }
-- 1.3.6.1.4.1.2011.6.25.1.12.2.5
hw1588ACRInfoMode OBJECT-TYPE
SYNTAX INTEGER
{
multicast(1),
unicast(2)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"PTPACR Info Mode,the default value is multicast(1).
Options:
1. multicast(1) - the 1588 ACR info mode is multicast.
2. unicast(2) - the 1588 ACR info mode is unicast.
"
::= { hw1588ACRManage 5 }
-- 1.3.6.1.4.1.2011.6.25.1.12.2.6
hw1588ACRReqSendTimeInterval OBJECT-TYPE
SYNTAX Integer32 (1..21)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"PTPACR req send time interval.
Options:
1. 1/1024s(1) - indicates that the time interval is 1/1024s
2. 1/512s (2) - indicates that the time interval is 1/512s
3. 1/256s (3) - indicates that the time interval is 1/256s .
4. 1/128s (4) - indicates that the time interval is 1/128s .
5. 1/64s (5) - indicates that the time interval is 1/64s
6. 1/32s (6) - indicates that the time interval is 1/32s
7. 1/16s (7) - indicates that the time interval is 1/16s
8. 1/8s (8) - indicates that the time interval is 1/8s
9. 1/4s (9) - indicates that the time interval is 1/4s
10.1/2s (10) - indicates that the time interval is 1/2s
11.1s (11) - indicates that the time interval is 1s
12.2s (12) - indicates that the time interval is 2s
13.4s (13) - indicates that the time interval is 4s
14.8s (14) - indicates that the time interval is 8s
15.16s (15) - indicates that the time interval is 16s
16.32s (16) - indicates that the time interval is 32s
17.64s (17) - indicates that the time interval is 64s
18.128s (18) - indicates that the time interval is 128s
19.256s (19) - indicates that the time interval is 256s
20.512s (20) - indicates that the time interval is 512s
21.1024s (21) - indicates that the time interval is 1024s
"
::= { hw1588ACRManage 6 }
-- 1.3.6.1.4.1.2011.6.25.1.12.2.7
hw1588ACRSourceIp OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The IP address of local.
Default:0.0.0.0
"
::= { hw1588ACRManage 7 }
-- 1.3.6.1.4.1.2011.6.25.1.12.2.8
hw1588ACRDSCP OBJECT-TYPE
SYNTAX Integer32 (0..63)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The dscp of ip head.
Range: 0-63
Default: 56"
::= { hw1588ACRManage 8 }
-- 1.3.6.1.4.1.2011.6.25.1.12.2.9
hw1588ACRVlan OBJECT-TYPE
SYNTAX Integer32 (0..4094)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"PTPACR VLAN: 0-4094"
::= { hw1588ACRManage 9 }
-- 1.3.6.1.4.1.2011.6.25.1.12.2.10
hw1588ACRVlanPRI OBJECT-TYPE
SYNTAX Integer32 (0..7)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"PTPACR VLAN priority: 0-7"
::= { hw1588ACRManage 10 }
-- 1.3.6.1.4.1.2011.6.25.1.12.2.11
hw1588ACRGlbEnable OBJECT-TYPE
SYNTAX INTEGER
{
disable(1),
enable(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The switch of 1588ACR.
Options:
1.disable(1) - disable 1588ACR function
2.enable(2) - enable 1588ACR function
Default: disable(1)
"
::= { hw1588ACRManage 11 }
-- 1.3.6.1.4.1.2011.6.25.1.12.2.12
hw1588ACRDeviceType OBJECT-TYPE
SYNTAX INTEGER
{
client(1),
server(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The running device type.
Options:
1.client(1) - running as client
2.server(2) - running as server
Default: client(1)
"
::= { hw1588ACRManage 12 }
-- 1.3.6.1.4.1.2011.6.25.1.12.2.13
hw1588ACRVpnInstance OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (1..31))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"VPN instance of 1588ACR using."
::= { hw1588ACRManage 13 }
-- 1.3.6.1.4.1.2011.6.25.1.12.2.14
hw1588ACRAnnounceInterval OBJECT-TYPE
SYNTAX Integer32 (7..14)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The interval of request for server tx announce packet.
Options:
1. 1/8s (7) - indicates that the time interval is 1/8s
2. 1/4s (8) - indicates that the time interval is 1/4s
3. 1/2s (9) - indicates that the time interval is 1/2s
4. 1s (10) - indicates that the time interval is 1s
5. 2s (11) - indicates that the time interval is 2s
6. 4s (12) - indicates that the time interval is 4s
7. 8s (13) - indicates that the time interval is 8s
8. 16s (14) - indicates that the time interval is 16s
Default: 11
"
::= { hw1588ACRManage 14 }
-- 1.3.6.1.4.1.2011.6.25.1.12.2.15
hw1588ACRSyncInterval OBJECT-TYPE
SYNTAX Integer32 (3..14)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The interval of request for server tx sync packet.
Options:
1. 1/128s (3) - indicates that the time interval is 1/128s
2. 1/64s (4) - indicates that the time interval is 1/64s
3. 1/32s (5) - indicates that the time interval is 1/32s
4. 1/16s (6) - indicates that the time interval is 1/16s
5. 1/8s (7) - indicates that the time interval is 1/8s
6. 1/4s (8) - indicates that the time interval is 1/4s
7. 1/2s (9) - indicates that the time interval is 1/2s
8. 1s (10) - indicates that the time interval is 1s
9. 2s (11) - indicates that the time interval is 2s
10. 4s (12) - indicates that the time interval is 4s
11. 8s (13) - indicates that the time interval is 8s
12. 16s (14) - indicates that the time interval is 16s
Default: 3
"
::= { hw1588ACRManage 15 }
-- 1.3.6.1.4.1.2011.6.25.1.12.2.16
hw1588ACRDelayRespInterval OBJECT-TYPE
SYNTAX Integer32 (3..14)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The interval of request for server tx delay response packet.
Options:
1. 1/128s (3) - indicates that the time interval is 1/128s
2. 1/64s (4) - indicates that the time interval is 1/64s
3. 1/32s (5) - indicates that the time interval is 1/32s
4. 1/16s (6) - indicates that the time interval is 1/16s
5. 1/8s (7) - indicates that the time interval is 1/8s
6. 1/4s (8) - indicates that the time interval is 1/4s
7. 1/2s (9) - indicates that the time interval is 1/2s
8. 1s (10) - indicates that the time interval is 1s
9. 2s (11) - indicates that the time interval is 2s
10. 4s (12) - indicates that the time interval is 4s
11. 8s (13) - indicates that the time interval is 8s
12. 16s (14) - indicates that the time interval is 16s
Default: 3
"
::= { hw1588ACRManage 16 }
-- 1.3.6.1.4.1.2011.6.25.1.12.2.17
hw1588ACRAnnounceDuration OBJECT-TYPE
SYNTAX Integer32 (60..1000)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The timeout time of announce renegotiation.
Range: 60-1000 -- 60s-1000s
Default: 300 -- 300s
"
::= { hw1588ACRManage 17 }
-- 1.3.6.1.4.1.2011.6.25.1.12.2.18
hw1588ACRSyncDuration OBJECT-TYPE
SYNTAX Integer32 (60..1000)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The timeout time of sync renegotiation.
Range: 60-1000 -- 60s-1000s
Default: 300 -- 300s
"
::= { hw1588ACRManage 18 }
-- 1.3.6.1.4.1.2011.6.25.1.12.2.19
hw1588ACRDelayRespDuration OBJECT-TYPE
SYNTAX Integer32 (60..1000)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The timeout time of delay response renegotiation.
Range: 60-1000 -- 60s-1000s
Default: 300 -- 300s
"
::= { hw1588ACRManage 19 }
-- 1.3.6.1.4.1.2011.6.25.1.12.2.20
hw1588ACRNegoMode OBJECT-TYPE
SYNTAX INTEGER
{
oneWay(1),
twoWay(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The negotiation mode.
Options:
1.oneWay(1) - one way
2.twoWay(2) - two way
Default: oneWay(1)
"
::= { hw1588ACRManage 20 }
-- 1.3.6.1.4.1.2011.6.25.1.12.2.21
hw1588ACRNegoEnable OBJECT-TYPE
SYNTAX INTEGER
{
disable(1),
enable(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The switch of 1588ACR negotiation.
Options:
1.disable(1) - disable 1588ACR negotiation
2.enable(2) - enable 1588ACR negotiation
Default: disable(1)
"
::= { hw1588ACRManage 21 }
-- 1.3.6.1.4.1.2011.6.25.1.12.2.22
hw1588ACRTraceSourceId OBJECT-TYPE
SYNTAX INTEGER
{
local(1),
server1(2),
server2(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The trace source server ID.
Options:
1.local(1) - no trace source
2.server1(2) - server1
3.server2(3) - server2
"
::= { hw1588ACRManage 22 }
-- 1.3.6.1.4.1.2011.6.25.1.12.3
hw1588ACRDfx OBJECT IDENTIFIER ::= { hw1588ACR 3 }
-- 1.3.6.1.4.1.2011.6.25.1.12.3.1
hw1588ACRDfxPosMinPdCur OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The current positive min packet delay.
"
::= { hw1588ACRDfx 1 }
-- 1.3.6.1.4.1.2011.6.25.1.12.3.2
hw1588ACRDfxPosMinPdMin OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The min positive min packet delay.
"
::= { hw1588ACRDfx 2 }
-- 1.3.6.1.4.1.2011.6.25.1.12.3.3
hw1588ACRDfxPosMinPdMax OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The max positive min packet delay.
"
::= { hw1588ACRDfx 3 }
-- 1.3.6.1.4.1.2011.6.25.1.12.3.4
hw1588ACRDfxPosMinPdMean OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The mean positive min packet delay.
"
::= { hw1588ACRDfx 4 }
-- 1.3.6.1.4.1.2011.6.25.1.12.3.5
hw1588ACRDfxPosMinPdv OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The positive min packet delay variation.
"
::= { hw1588ACRDfx 5 }
-- 1.3.6.1.4.1.2011.6.25.1.12.3.6
hw1588ACRDfxPosMaxPdCur OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The current positive max packet delay.
"
::= { hw1588ACRDfx 6 }
-- 1.3.6.1.4.1.2011.6.25.1.12.3.7
hw1588ACRDfxPosMaxPdMin OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The min positive max packet delay.
"
::= { hw1588ACRDfx 7 }
-- 1.3.6.1.4.1.2011.6.25.1.12.3.8
hw1588ACRDfxPosMaxPdMax OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The max positive max packet delay.
"
::= { hw1588ACRDfx 8 }
-- 1.3.6.1.4.1.2011.6.25.1.12.3.9
hw1588ACRDfxPosMaxPdMean OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The mean positive max packet delay.
"
::= { hw1588ACRDfx 9 }
-- 1.3.6.1.4.1.2011.6.25.1.12.3.10
hw1588ACRDfxPosMaxPdv OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The positive max packet delay variation.
"
::= { hw1588ACRDfx 10 }
-- 1.3.6.1.4.1.2011.6.25.1.12.3.11
hw1588ACRDfxNegMinPdCur OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The current negative min packet delay.
"
::= { hw1588ACRDfx 11 }
-- 1.3.6.1.4.1.2011.6.25.1.12.3.12
hw1588ACRDfxNegMinPdMin OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The min negative min packet delay.
"
::= { hw1588ACRDfx 12 }
-- 1.3.6.1.4.1.2011.6.25.1.12.3.13
hw1588ACRDfxNegMinPdMax OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The max negative min packet delay.
"
::= { hw1588ACRDfx 13 }
-- 1.3.6.1.4.1.2011.6.25.1.12.3.14
hw1588ACRDfxNegMinPdMean OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The mean negative min packet delay.
"
::= { hw1588ACRDfx 14 }
-- 1.3.6.1.4.1.2011.6.25.1.12.3.15
hw1588ACRDfxNegMinPdv OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The negative min packet delay variation.
"
::= { hw1588ACRDfx 15 }
-- 1.3.6.1.4.1.2011.6.25.1.12.3.16
hw1588ACRDfxNegMaxPdCur OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The current negative max packet delay.
"
::= { hw1588ACRDfx 16 }
-- 1.3.6.1.4.1.2011.6.25.1.12.3.17
hw1588ACRDfxNegMaxPdMin OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The min negative max packet delay.
"
::= { hw1588ACRDfx 17 }
-- 1.3.6.1.4.1.2011.6.25.1.12.3.18
hw1588ACRDfxNegMaxPdMax OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The max negative max packet delay.
"
::= { hw1588ACRDfx 18 }
-- 1.3.6.1.4.1.2011.6.25.1.12.3.19
hw1588ACRDfxNegMaxPdMean OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The mean negative max packet delay.
"
::= { hw1588ACRDfx 19 }
-- 1.3.6.1.4.1.2011.6.25.1.12.3.20
hw1588ACRDfxNegMaxPdv OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The negative max packet delay variation.
"
::= { hw1588ACRDfx 20 }
-- 1.3.6.1.4.1.2011.6.25.1.12.4
hw1588ACRServerTable OBJECT-TYPE
SYNTAX SEQUENCE OF Hw1588ACRServerEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"1588ACR server management table.
The index of this table is server index.
"
::= { hw1588ACR 4 }
-- 1.3.6.1.4.1.2011.6.25.1.12.4.1
hw1588ACRServerEntry OBJECT-TYPE
SYNTAX Hw1588ACRServerEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"1588ACR server management table.
The index of this entry is server index.
"
INDEX { hw1588ACRServerIndex }
::= { hw1588ACRServerTable 1 }
Hw1588ACRServerEntry ::=
SEQUENCE {
hw1588ACRServerIndex
Integer32,
hw1588ACRServerIpAddr
IpAddress,
hw1588ACRServerNegoStatus
INTEGER,
hw1588ACRServerSsm
INTEGER,
hw1588ACRServerPriority
Integer32,
hw1588ACRServerPTSFLossAnnounce
INTEGER,
hw1588ACRServerPTSFLossSync
INTEGER,
hw1588ACRServerPTSFLossDelayResp
INTEGER
}
-- 1.3.6.1.4.1.2011.6.25.1.12.4.1.1
hw1588ACRServerIndex OBJECT-TYPE
SYNTAX Integer32 (1..2)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The server index.
Range: 1-2
"
::= { hw1588ACRServerEntry 1 }
-- 1.3.6.1.4.1.2011.6.25.1.12.4.1.2
hw1588ACRServerIpAddr OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The IP address of server."
::= { hw1588ACRServerEntry 2 }
-- 1.3.6.1.4.1.2011.6.25.1.12.4.1.3
hw1588ACRServerNegoStatus OBJECT-TYPE
SYNTAX INTEGER
{
init(1),
success(2),
failed(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The status of negotiation.
Options:
1. init(1) - no enable negotiation
2. success(2) - negotiate succesfully
3. failed(3) - negotiate failed
"
::= { hw1588ACRServerEntry 3 }
-- 1.3.6.1.4.1.2011.6.25.1.12.4.1.4
hw1588ACRServerSsm OBJECT-TYPE
SYNTAX INTEGER
{
prc(2),
ssua(4),
ssub(8),
sec(11),
dnu(15)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The quality level.
Options:
1. prc(2) - prc
2. ssua(4) - ssua
3. ssub(8) - ssub
4. sec(11) - sec
5. dnu(15) - dnu
"
::= { hw1588ACRServerEntry 4 }
-- 1.3.6.1.4.1.2011.6.25.1.12.4.1.5
hw1588ACRServerPriority OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The priority.
"
::= { hw1588ACRServerEntry 5 }
-- 1.3.6.1.4.1.2011.6.25.1.12.4.1.6
hw1588ACRServerPTSFLossAnnounce OBJECT-TYPE
SYNTAX INTEGER
{
normal(1),
failed(2),
none(255)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The announce PTSF status.
Options:
1. normal(1) - status is normal
2. failed(2) - status is abnormal
3. none(255) - not referenced"
::= { hw1588ACRServerEntry 6 }
-- 1.3.6.1.4.1.2011.6.25.1.12.4.1.7
hw1588ACRServerPTSFLossSync OBJECT-TYPE
SYNTAX INTEGER
{
normal(1),
failed(2),
none(255)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The sync PTSF status.
Options:
1. normal(1) - status is normal
2. failed(2) - status is abnormal
3. none(255) - not referenced"
::= { hw1588ACRServerEntry 7 }
-- 1.3.6.1.4.1.2011.6.25.1.12.4.1.8
hw1588ACRServerPTSFLossDelayResp OBJECT-TYPE
SYNTAX INTEGER
{
normal(1),
failed(2),
none(255)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The delay response PTSF status.
Options:
1. normal(1) - status is normal
2. failed(2) - status is abnormal
3. none(255) - not referenced"
::= { hw1588ACRServerEntry 8 }
-- 1.3.6.1.4.1.2011.6.25.2
hwOntClkMibObjects OBJECT IDENTIFIER ::= { hwClk 2 }
-- 1.3.6.1.4.1.2011.6.25.2.1
hwOntClkProfileGlobalInfoTable OBJECT-TYPE
SYNTAX SEQUENCE OF HwOntClkProfileGlobalInfoEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"ont clk profile global management table.
"
::= { hwOntClkMibObjects 1 }
-- 1.3.6.1.4.1.2011.6.25.2.1.1
hwOntClkProfileGlobalInfoEntry OBJECT-TYPE
SYNTAX HwOntClkProfileGlobalInfoEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table manage ont clk profile global setting."
INDEX { IMPLIED hwOntClkProfileInfoNameIndex}
::= { hwOntClkProfileGlobalInfoTable 1 }
HwOntClkProfileGlobalInfoEntry ::=
SEQUENCE {
hwOntClkProfileInfoNameIndex
OCTET STRING,
hwOntClkProfileRowStatus
RowStatus,
hwOntClkProfileType
INTEGER,
hwOntClkProfileQlMode
INTEGER,
hwOntClkProfilePtpSwitch
INTEGER,
hwOntClkProfilePtpBmcSwitch
INTEGER,
hwOntClkProfilePtpDomain
Integer32
}
-- 1.3.6.1.4.1.2011.6.25.2.1.1.1
hwOntClkProfileInfoNameIndex OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (1..32))
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Ont clk Profile name Index.
"
::= { hwOntClkProfileGlobalInfoEntry 1 }
-- 1.3.6.1.4.1.2011.6.25.2.1.1.2
hwOntClkProfileRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Rowstatus of the Ont clk profile.
Options:
1. createAndGo(4) - Creates an Ont clk profile
2. destroy(6) - Destroys Ont clk profile.
"
::= { hwOntClkProfileGlobalInfoEntry 2 }
-- 1.3.6.1.4.1.2011.6.25.2.1.1.3
hwOntClkProfileType OBJECT-TYPE
SYNTAX INTEGER
{
bc(1),
tbc(2)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The Ont Clk Profile device type.
Options:
1.bc - general
2.tbc - g.8273.1
Default: bc
"
::= { hwOntClkProfileGlobalInfoEntry 3 }
-- 1.3.6.1.4.1.2011.6.25.2.1.1.4
hwOntClkProfileQlMode OBJECT-TYPE
SYNTAX INTEGER
{
enable(1),
disable(2)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The switch of Ont Clk QL-MODE.
Options:
1.enable(1) - enable QL-MODE
2.disable(2) - disable QL-MODE
Default: disable(2)
"
::= { hwOntClkProfileGlobalInfoEntry 4 }
-- 1.3.6.1.4.1.2011.6.25.2.1.1.5
hwOntClkProfilePtpSwitch OBJECT-TYPE
SYNTAX INTEGER
{
enable(1),
disable(2)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The switch of Ont PTP Switch.
Options:
1.enable(1) - enable ont clk profile ptp
2.disable(2) - disable ont clk profile ptp
Default: disable(2)
"
::= { hwOntClkProfileGlobalInfoEntry 5 }
-- 1.3.6.1.4.1.2011.6.25.2.1.1.6
hwOntClkProfilePtpBmcSwitch OBJECT-TYPE
SYNTAX INTEGER
{
enable(1),
disable(2)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The switch of Ont PTP BMC Switch.
Options:
1.enable(1) - enable ont ptp BMC
2.disable(2) - disable ptp BMC
Default: disable(2)
"
::= { hwOntClkProfileGlobalInfoEntry 6 }
-- 1.3.6.1.4.1.2011.6.25.2.1.1.7
hwOntClkProfilePtpDomain OBJECT-TYPE
SYNTAX Integer32 (0..255)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"PTP domain value.
BC:
Range: 0-255
Default: 0
T-BC:
Range: 24-43
Default: 24
"
::= { hwOntClkProfileGlobalInfoEntry 7 }
-- 1.3.6.1.4.1.2011.6.25.2.2
hwOntClkProfilePortInfoTable OBJECT-TYPE
SYNTAX SEQUENCE OF HwOntClkProfilePortInfoEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"ont clk profile global port management table.
"
::= { hwOntClkMibObjects 2 }
-- 1.3.6.1.4.1.2011.6.25.2.2.1
hwOntClkProfilePortInfoEntry OBJECT-TYPE
SYNTAX HwOntClkProfilePortInfoEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table manage ont clk profile port setting."
INDEX { hwOntClkProfileInfoNameIndex, hwOntClkProfOntPortCfgOntPhyType, hwOntClkProfOntPortCfgOntPhyIndex }
::= { hwOntClkProfilePortInfoTable 1 }
HwOntClkProfilePortInfoEntry ::=
SEQUENCE {
hwOntClkProfOntPortCfgOntPhyType
INTEGER,
hwOntClkProfOntPortCfgOntPhyIndex
Integer32,
hwOntClkProfOntPortPtpSwtich
INTEGER,
hwOntClkProfOntPortPtpStep
INTEGER,
hwOntClkProfOntPortPtpDelayMode
INTEGER,
hwOntClkProfOntPortPtpAnnInterval
Integer32,
hwOntClkProfOntPortPtpSyncInterval
Integer32,
hwOntClkProfOntPortPtpReqInterval
Integer32,
hwOntClkProfOntPortPtpMsgFormat
INTEGER,
hwOntClkProfOntPortPtpTransportType
INTEGER,
hwOntClkProfOntPortPtpVlan
Integer32,
hwOntClkProfOntPortPtpVlanPri
Integer32,
hwOntClkProfOntPortPtpUdpDscp
Integer32,
hwOntClkProfOntPortPtpDestMac
MacAddress
}
-- 1.3.6.1.4.1.2011.6.25.2.2.1.1
hwOntClkProfOntPortCfgOntPhyType OBJECT-TYPE
SYNTAX INTEGER
{
t1(13),
e1(14),
fe(24),
ge(34),
vdsl(37),
moca(46),
eth(47),
iphost(50)
}
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This object indicates the port type of the ONT.
"
::= { hwOntClkProfilePortInfoEntry 1 }
-- 1.3.6.1.4.1.2011.6.25.2.2.1.2
hwOntClkProfOntPortCfgOntPhyIndex OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This object indicates the port index of the ONT.
"
::= { hwOntClkProfilePortInfoEntry 2 }
-- 1.3.6.1.4.1.2011.6.25.2.2.1.3
hwOntClkProfOntPortPtpSwtich OBJECT-TYPE
SYNTAX INTEGER
{
enable(1),
disable(2)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
" Enable or disable the 1588 function of PTP port.
Options:
1. enable(1) -Enable the 1588 function of this port
2. disable(2) -Disable the 1588 function of this port
Default: disable(2)
"
::= { hwOntClkProfilePortInfoEntry 3 }
-- 1.3.6.1.4.1.2011.6.25.2.2.1.4
hwOntClkProfOntPortPtpStep OBJECT-TYPE
SYNTAX INTEGER
{
oneStep(1),
twoStep(2)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
" Clock step mode.
Options:
1.oneStep(1) - indicates that clock step mode is one-step.
2.twoStep(2) - indicates that clock step mode is two-step.
Default: oneStep(1)
"
::= { hwOntClkProfilePortInfoEntry 4 }
-- 1.3.6.1.4.1.2011.6.25.2.2.1.5
hwOntClkProfOntPortPtpDelayMode OBJECT-TYPE
SYNTAX INTEGER
{
delayMechanism(1),
pdelayMechanism(2)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
" Delay measurement mechanism.
Options:
1.delayMechanism(1) - indicates that delay mechanism is delay-mechanism.
2.pdelayMechanism(2) - indicates that delay mechanism is pdelay-mechanism.
Default: delayMechanism(1)
"
::= { hwOntClkProfilePortInfoEntry 5 }
-- 1.3.6.1.4.1.2011.6.25.2.2.1.6
hwOntClkProfOntPortPtpAnnInterval OBJECT-TYPE
SYNTAX Integer32 (6..14)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Interval for sending announce packets.
BC:
Default: 1/8s(7)
Options:
1. 1/16s (6) - indicates that the time interval is 1/16s
2. 1/8s (7) - indicates that the time interval is 1/8s
3. 1/4s (8) - indicates that the time interval is 1/4s
4. 1/2s (9) - indicates that the time interval is 1/2s
5. 1s (10) - indicates that the time interval is 1s
6. 2s (11) - indicates that the time interval is 2s
7. 4s (12) - indicates that the time interval is 4s
8. 8s (13) - indicates that the time interval is 8s
9. 16s (14) - indicates that the time interval is 16s
T-BC:
1/8s (7) - indicates that the time interval is 1/8s
"
::= { hwOntClkProfilePortInfoEntry 6 }
-- 1.3.6.1.4.1.2011.6.25.2.2.1.7
hwOntClkProfOntPortPtpSyncInterval OBJECT-TYPE
SYNTAX Integer32 (2..11)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Interval for sending sync packets.
BC:
Default: 1/16s(6)
Options:
1. 1/256s (2) - indicates that the time interval is 1/256s
2. 1/128s (3) - indicates that the time interval is 1/128s
3. 1/64s (4) - indicates that the time interval is 1/64s
4. 1/32s (5) - indicates that the time interval is 1/32s
5. 1/16s (6) - indicates that the time interval is 1/16s
6. 1/8s (7) - indicates that the time interval is 1/8s
7. 1/4s (8) - indicates that the time interval is 1/4s
8. 1/2s (9) - indicates that the time interval is 1/24s
9. 1s (10) - indicates that the time interval is 1s
10.2s (11) - indicates that the time interval is 2s
T-BC:
1/16s (6) - indicates that the time interval is 1/16s
"
::= { hwOntClkProfilePortInfoEntry 7 }
-- 1.3.6.1.4.1.2011.6.25.2.2.1.8
hwOntClkProfOntPortPtpReqInterval OBJECT-TYPE
SYNTAX Integer32 (6..14)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Interval for sending req packets.
BC:
Default: 1/8s(7)
Options:
1. 1/16s (6) - indicates that the time interval is 1/16s
3. 1/8s (7) - indicates that the time interval is 1/8s
3. 1/4s (8) - indicates that the time interval is 1/4s
4. 1/2s (9) - indicates that the time interval is 1/2s
5. 1s (10) - indicates that the time interval is 1s
6. 2s (11) - indicates that the time interval is 2s
7. 4s (12) - indicates that the time interval is 4s
8. 8s (13) - indicates that the time interval is 8s
9. 16s (14) - indicates that the time interval is 16s
T-BC:
1/16s (6) - indicates that the time interval is 1/16s
"
::= { hwOntClkProfilePortInfoEntry 8 }
-- 1.3.6.1.4.1.2011.6.25.2.2.1.9
hwOntClkProfOntPortPtpMsgFormat OBJECT-TYPE
SYNTAX INTEGER
{
ptpeth(1),
ptpip(2)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
" PTP message encapsulation format,the default value is PTPETH(1).
Options:
1. ptpeth(1) - indicates that the PTP message is encapsulated into an Ethernet packet
2. ptpip(2) - indicates that the PTP message is encapsulated into an IP packet
"
::= { hwOntClkProfilePortInfoEntry 9 }
-- 1.3.6.1.4.1.2011.6.25.2.2.1.10
hwOntClkProfOntPortPtpTransportType OBJECT-TYPE
SYNTAX INTEGER
{
multicast(1),
unicast(2)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
" PTP info mode.
Default: multicast(1)
Options:
1. multicast(1) - indicates that the Info mode of the 1588 clock PTP port is multicast
2. unicast(2) - indicates that the Info mode of the 1588 clock PTP port is unicast
"
::= { hwOntClkProfilePortInfoEntry 10 }
-- 1.3.6.1.4.1.2011.6.25.2.2.1.11
hwOntClkProfOntPortPtpVlan OBJECT-TYPE
SYNTAX Integer32 (-1 | 0 | 1..4094)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"VLAN of UDP-encapsulated or MAC-encapsulated packets.
Default: untag(0)
Invalid(-1)
"
::= { hwOntClkProfilePortInfoEntry 11 }
-- 1.3.6.1.4.1.2011.6.25.2.2.1.12
hwOntClkProfOntPortPtpVlanPri OBJECT-TYPE
SYNTAX Integer32 (-1 | 0..7)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"VLAN priority of UDP-encapsulated or MAC-encapsulated packets.
Default:7
Invalid(-1)"
::= { hwOntClkProfilePortInfoEntry 12 }
-- 1.3.6.1.4.1.2011.6.25.2.2.1.13
hwOntClkProfOntPortPtpUdpDscp OBJECT-TYPE
SYNTAX Integer32 (-1 | 0..63)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"DSCP of UDP-encapsulated packets.
Default:56
Invalid(-1)
"
::= { hwOntClkProfilePortInfoEntry 13 }
-- 1.3.6.1.4.1.2011.6.25.2.2.1.14
hwOntClkProfOntPortPtpDestMac OBJECT-TYPE
SYNTAX MacAddress
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Destination MAC address of MAC-encapsulated packets.
T-BC:Supports only MAC-encapsulated packets and supports multicast MAC address configuration.
It can be 01-80-C2-00-00-0E (default) and 01-1B-19-00-00-00.
This attribute is invalid in BC mode.
"
::= { hwOntClkProfilePortInfoEntry 14 }
-- 1.3.6.1.4.1.2011.6.25.2.3
hwOntClkGlobalInfoTable OBJECT-TYPE
SYNTAX SEQUENCE OF HwOntClkGlobalInfoEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"ont clk global management table.
"
::= { hwOntClkMibObjects 3 }
-- 1.3.6.1.4.1.2011.6.25.2.3.1
hwOntClkGlobalInfoEntry OBJECT-TYPE
SYNTAX HwOntClkGlobalInfoEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table manage ont clk global configuration table."
INDEX { ifIndex, hwOntClkObjectIndex }
::= { hwOntClkGlobalInfoTable 1 }
HwOntClkGlobalInfoEntry ::=
SEQUENCE {
hwOntClkObjectIndex
Integer32,
hwOntObjectClockProfileName
OCTET STRING,
hwOntObjectPtpClockId
OCTET STRING,
hwOntObjectClkWorkMode
INTEGER,
hwOntObjectClkLockState
INTEGER,
hwOntObjectClkSrcState
INTEGER,
hwOntObjectClkSrcQL
INTEGER,
hwOntObjectPtpLockState
INTEGER,
hwOntObjectPtpSrcState
INTEGER,
hwOntObjectPtpGmClockID
OCTET STRING,
hwOntObjectPtpParentClockID
OCTET STRING,
hwOntObjectPtpParentPortID
Integer32,
hwOntObjectPtpGmPriority1
Integer32,
hwOntObjectPtpGmPriority2
Integer32,
hwOntObjectPtpGmAccuracy
Integer32,
hwOntObjectPtpGmClockClass
Integer32,
hwOntObjectPtpGmTimeSource
INTEGER,
hwOntObjectPtpGmTimeScale
INTEGER,
hwOntObjectPtpFrequencyTraceable
INTEGER,
hwOntObjectPtpTimeTraceable
INTEGER,
hwOntObjectPtpStepRemoved
Integer32
}
-- 1.3.6.1.4.1.2011.6.25.2.3.1.1
hwOntClkObjectIndex OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"ONT ID.
"
::= { hwOntClkGlobalInfoEntry 1 }
-- 1.3.6.1.4.1.2011.6.25.2.3.1.2
hwOntObjectClockProfileName OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (0..32))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The name of ONT's clock profile.
When the string length is 0, it means the unbinding operation."
::= { hwOntClkGlobalInfoEntry 2 }
-- 1.3.6.1.4.1.2011.6.25.2.3.1.3
hwOntObjectPtpClockId OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (8))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The 1588 clock identity of device.
The first 4 bytes are OUI and product ID and do not need to be configured."
::= { hwOntClkGlobalInfoEntry 3 }
-- 1.3.6.1.4.1.2011.6.25.2.3.1.4
hwOntObjectClkWorkMode OBJECT-TYPE
SYNTAX INTEGER
{
trace(1),
surge(2),
keep(3),
snap(4),
thirdsurge(5),
invalid(-1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Clock out working mode.
Options:
1.trace(1) - indicates that the clock is working in tracing mode.
2.surge(2) - indicates that the clock is working in surge mode.
3.keep(3) - indicates that the clock is working in keeping mode.
4.snap(4) - indicates that the clock is working in snapping mode.
5.thirdsurge(5) - indicates that the clock is working in thirdsurge mode.
6.invalid(-1) - indicates that it is not be queried.
"
::= { hwOntClkGlobalInfoEntry 4 }
-- 1.3.6.1.4.1.2011.6.25.2.3.1.5
hwOntObjectClkLockState OBJECT-TYPE
SYNTAX INTEGER
{
locked(1),
unlocked(2),
invalid(-1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Clock lock state.
Options:
1.locked(1) - indicates that the clock is locked.
2.unlocked(2) - indicates that the clock is unlocked.
3.invalid(-1) - indicates that it is not be queried.
"
::= { hwOntClkGlobalInfoEntry 5 }
-- 1.3.6.1.4.1.2011.6.25.2.3.1.6
hwOntObjectClkSrcState OBJECT-TYPE
SYNTAX INTEGER
{
none(1),
normal(2),
failure(3),
failureLoss(4),
failureEFD(5),
invalid(-1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Clock source state.
Options:
1.none(1) - indicates that the clock source index isn't configured.
2.normal(2) - indicates that the state of the clock source is active.
3.failure(3) - indicates that the state of the clock source fails and this leaf is not used on the OLT.
4.failureLoss(4) - indicates that the clock source fails due to signal loss.
5.failureEFD(5) - indicates that the clock source fails due to frequency offset.
6.invalid(-1) - indicates that it is not be queried.
"
::= { hwOntClkGlobalInfoEntry 6 }
-- 1.3.6.1.4.1.2011.6.25.2.3.1.7
hwOntObjectClkSrcQL OBJECT-TYPE
SYNTAX INTEGER
{
qlPRC(2),
qlSsuA(4),
qlSsuB(8),
qlSEC(11),
qlDNU(15),
qlCLEAR(255),
invalid(-1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Clock source quality level:
Options:
1. qlPRC(2) - indicates that primary reference clock.
2. qlSsuA(4) - indicates that the clock signal comes from class I or class.
V sub-clock prescribed on G.812 protocol.
3. qlSsuB(8) - indicates that the clock signal comes from class VI sub-clock.
prescribed on G.812 protocol.
4. qlSEC(11) - indicates that the clock signal comes from SEC(SDH Equipment.
Clock) prescribed on G.813 protocol.
5. qlDNU(15) - indicates that the clock signal can't be used for synchronization.
6. qlCLEAR(255) - indicates that it is a wrong clock quality level.
7. invalid(-1) - indicates that it is not be queried.
"
::= { hwOntClkGlobalInfoEntry 7 }
-- 1.3.6.1.4.1.2011.6.25.2.3.1.8
hwOntObjectPtpLockState OBJECT-TYPE
SYNTAX INTEGER
{
locked(1),
unlocked(2),
invalid(-1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"PTP lock state.
Options:
1.locked(1) - indicates that the PTP is locked.
2.unlocked(2) - indicates that the PTP is unlocked.
3.invalid(-1) - indicates that it is not be queried.
"
::= { hwOntClkGlobalInfoEntry 8 }
-- 1.3.6.1.4.1.2011.6.25.2.3.1.9
hwOntObjectPtpSrcState OBJECT-TYPE
SYNTAX INTEGER
{
none(1),
normal(2),
failure(3),
invalid(-1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
" 1588 source status:
Options:
1.none(1) - indicates that the 1588 source index is not configured.
2.normal(2) - indicates that the status of 1588 source is normal.
3.failure(3) - indicates that the status of 1588 source is faulty.
4.invalid(-1) - indicates that it is not be queried.
"
::= { hwOntClkGlobalInfoEntry 9 }
-- 1.3.6.1.4.1.2011.6.25.2.3.1.10
hwOntObjectPtpGmClockID OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (16))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Grand master clock ID."
::= { hwOntClkGlobalInfoEntry 10 }
-- 1.3.6.1.4.1.2011.6.25.2.3.1.11
hwOntObjectPtpParentClockID OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (16))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"PTP parent clockID."
::= { hwOntClkGlobalInfoEntry 11 }
-- 1.3.6.1.4.1.2011.6.25.2.3.1.12
hwOntObjectPtpParentPortID OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"PTP parent portnumber.
Invalid(-1)"
::= { hwOntClkGlobalInfoEntry 12 }
-- 1.3.6.1.4.1.2011.6.25.2.3.1.13
hwOntObjectPtpGmPriority1 OBJECT-TYPE
SYNTAX Integer32 (-1 | 0..255)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Grand master clock priority1.
Invalid(-1)"
::= { hwOntClkGlobalInfoEntry 13 }
-- 1.3.6.1.4.1.2011.6.25.2.3.1.14
hwOntObjectPtpGmPriority2 OBJECT-TYPE
SYNTAX Integer32 (-1 | 0..255)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Grand master clock priority2.
Invalid(-1)"
::= { hwOntClkGlobalInfoEntry 14 }
-- 1.3.6.1.4.1.2011.6.25.2.3.1.15
hwOntObjectPtpGmAccuracy OBJECT-TYPE
SYNTAX Integer32 (-1 | 0..255)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Grand master clock accuracy.
Invalid(-1)"
::= { hwOntClkGlobalInfoEntry 15 }
-- 1.3.6.1.4.1.2011.6.25.2.3.1.16
hwOntObjectPtpGmClockClass OBJECT-TYPE
SYNTAX Integer32 (-1 | 0..255)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Grand master clock class.
Invalid(-1)"
::= { hwOntClkGlobalInfoEntry 16}
-- 1.3.6.1.4.1.2011.6.25.2.3.1.17
hwOntObjectPtpGmTimeSource OBJECT-TYPE
SYNTAX INTEGER
{
atomicclock(16),
gps(32),
terrestrialradio(48),
ptp(64),
ntp(80),
handset(96),
other(144),
internaloscillator(160),
invalid(-1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
" Indicates the source of time used by the grandmaster clock.
Invalid(-1)"
::= { hwOntClkGlobalInfoEntry 17}
-- 1.3.6.1.4.1.2011.6.25.2.3.1.18
hwOntObjectPtpGmTimeScale OBJECT-TYPE
SYNTAX INTEGER
{
ptp(1),
arb(2),
invalid(-1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
" The time scale of the grandmaster clock.
Invalid(-1)"
::= { hwOntClkGlobalInfoEntry 18}
-- 1.3.6.1.4.1.2011.6.25.2.3.1.19
hwOntObjectPtpFrequencyTraceable OBJECT-TYPE
SYNTAX INTEGER
{
false(1),
true(2),
invalid(-1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"If not invalid, the value is true if the frequency determinning the timescale is traceable to a primary reference, otherwise the value is false.
Options:
1.false(1) - indicates that the frequency determinning the timescale isn't traceable to a primary reference.
2.true(2) - indicates that the frequency determinning the timescale is traceable to a primary reference.
3.invalid(-1) - indicates that it is not be queried."
::= { hwOntClkGlobalInfoEntry 19 }
-- 1.3.6.1.4.1.2011.6.25.2.3.1.20
hwOntObjectPtpTimeTraceable OBJECT-TYPE
SYNTAX INTEGER
{
false(1),
true(2),
invalid(-1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"If not invalid, the value is ture if the time is traceable to a primary reference, otherwise the value is false.
Options:
1.false(1) - indicates that the time isn't traceable to a primary reference.
2.true(2) - indicates that the time is traceable to a primary reference.
3.invalid(-1) - indicates that it is not be queried."
::= { hwOntClkGlobalInfoEntry 20 }
-- 1.3.6.1.4.1.2011.6.25.2.3.1.21
hwOntObjectPtpStepRemoved OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value is the number of paths (number of BCs) between the local clock and the grand master clock.
Invalid(-1)
"
::= { hwOntClkGlobalInfoEntry 21 }
-- 1.3.6.1.4.1.2011.6.25.2.4
hwOntClkPortInfoTable OBJECT-TYPE
SYNTAX SEQUENCE OF HwOntClkPortInfoEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"ont clk global discrete management table.
"
::= { hwOntClkMibObjects 4 }
-- 1.3.6.1.4.1.2011.6.25.2.4.1
hwOntClkPortInfoEntry OBJECT-TYPE
SYNTAX HwOntClkPortInfoEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table manage ont clk discrete configuration table."
INDEX { ifIndex, hwOntClkObjectIndex, hwOntClkObjectPortType, hwOntClkObjectPortId }
::= { hwOntClkPortInfoTable 1 }
HwOntClkPortInfoEntry ::=
SEQUENCE {
hwOntClkObjectPortType
INTEGER,
hwOntClkObjectPortId
Integer32,
hwOntClkObjectPortPtpMsgFormat
INTEGER,
hwOntClkObjectPortPtpTransportType
INTEGER,
hwOntClkObjectPortPtpVlan
Integer32,
hwOntClkObjectPortPtpVlanPri
Integer32,
hwOntClkObjectPortPtpUdpDscp
Integer32,
hwOntClkObjectPortPtpDestMac
MacAddress,
hwOntClkObjectPortPtpSrcIp
IpAddress,
hwOntClkObjectPortPtpDstIp
IpAddress
}
-- 1.3.6.1.4.1.2011.6.25.2.4.1.1
hwOntClkObjectPortType OBJECT-TYPE
SYNTAX INTEGER
{
t1(13),
e1(14),
fe(24),
ge(34),
vdsl(37),
moca(46),
eth(47),
iphost(50)
}
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This object indicates the port type of the ONT."
::= { hwOntClkPortInfoEntry 1 }
-- 1.3.6.1.4.1.2011.6.25.2.4.1.2
hwOntClkObjectPortId OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This object indicates the port index of the ONT."
::= { hwOntClkPortInfoEntry 2 }
-- 1.3.6.1.4.1.2011.6.25.2.4.1.3
hwOntClkObjectPortPtpMsgFormat OBJECT-TYPE
SYNTAX INTEGER
{
ptpeth(1),
ptpip(2),
default(5),
invalid(-1)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"PTP message encapsulation format,the default value is PTPETH(1).
Options:
1. ptpeth(1) - indicates that the PTP message is encapsulated into an Ethernet packet.
2. ptpip(2) - indicates that the PTP message is encapsulated into an IP packet.
3. default(5) - indicates that the ont clk discrete configurations revert back to default.
4. invalid(-1)- indicates that it is not be queried."
::= { hwOntClkPortInfoEntry 3 }
-- 1.3.6.1.4.1.2011.6.25.2.4.1.4
hwOntClkObjectPortPtpTransportType OBJECT-TYPE
SYNTAX INTEGER
{
multicast(1),
unicast(2),
invalid(-1)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"PTP info mode.
Default: multicast(1)
Options:
1. multicast(1) - indicates that the Info mode of the PTP port is multicast.
2. unicast(2) - indicates that the PTP info mode of the PTP port is unicast.
3. invalid(-1) - indicates that it is not be queried.
"
::= { hwOntClkPortInfoEntry 4 }
-- 1.3.6.1.4.1.2011.6.25.2.4.1.5
hwOntClkObjectPortPtpVlan OBJECT-TYPE
SYNTAX Integer32 (-1 | 0 | 1..4094)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"VLAN of UDP-encapsulated or MAC-encapsulated packets.
Default: untag(0)
Invalid(-1)"
::= { hwOntClkPortInfoEntry 5 }
-- 1.3.6.1.4.1.2011.6.25.2.4.1.6
hwOntClkObjectPortPtpVlanPri OBJECT-TYPE
SYNTAX Integer32 (-1 | 0..7)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"VLAN priority of UDP-encapsulated or MAC-encapsulated packets.
Default:7
Invalid(-1)"
::= { hwOntClkPortInfoEntry 6 }
-- 1.3.6.1.4.1.2011.6.25.2.4.1.7
hwOntClkObjectPortPtpUdpDscp OBJECT-TYPE
SYNTAX Integer32 (-1 | 0..63)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"DSCP of UDP-encapsulated packets.
Default:56
Invalid(-1)
"
::= { hwOntClkPortInfoEntry 7 }
-- 1.3.6.1.4.1.2011.6.25.2.4.1.8
hwOntClkObjectPortPtpDestMac OBJECT-TYPE
SYNTAX MacAddress
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Destination MAC address of UDP-encapsulated or MAC-encapsulated packets.
Invalid(ff-ff-ff-ff-ff-ff)
"
::= { hwOntClkPortInfoEntry 8 }
-- 1.3.6.1.4.1.2011.6.25.2.4.1.9
hwOntClkObjectPortPtpSrcIp OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Source IP address of UDP-encapsulated packets.
Default:0.0.0.0"
::= { hwOntClkPortInfoEntry 9 }
-- 1.3.6.1.4.1.2011.6.25.2.4.1.10
hwOntClkObjectPortPtpDstIp OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"
BC:This attribute cannot be configured and can only be set to the default value in multicast mode.
It can be configured only in unicast mode.
This attribute is invalid in T-BC mode.
"
::= { hwOntClkPortInfoEntry 10 }
END
--
-- HUAWEI-CLK-MIB.MIB
--