1864 lines
83 KiB
Plaintext
1864 lines
83 KiB
Plaintext
-- ============================================================================
|
|
-- Copyright (C) 2012 by HUAWEI TECHNOLOGIES. All rights reserved.
|
|
-- Description: This MIB is used for defining Huawei's BTEST MIB objects, which
|
|
-- is used for Broad test.
|
|
-- Reference:
|
|
-- Version: V3.14
|
|
-- ============================================================================
|
|
HUAWEI-BTEST-MIB DEFINITIONS ::= BEGIN
|
|
|
|
IMPORTS
|
|
huaweiUtility
|
|
FROM HUAWEI-MIB
|
|
HWPortType
|
|
FROM HUAWEI-TC-MIB
|
|
ifIndex
|
|
FROM IF-MIB
|
|
hwFrameIndex,hwSlotIndex
|
|
FROM HUAWEI-DEVICE-MIB
|
|
Integer32, Unsigned32, OBJECT-TYPE, MODULE-IDENTITY, NOTIFICATION-TYPE
|
|
FROM SNMPv2-SMI
|
|
TEXTUAL-CONVENTION, RowStatus
|
|
FROM SNMPv2-TC
|
|
hwTestGroupNo
|
|
FROM HUAWEI-COMMTEST-MIB;
|
|
|
|
hwBTest MODULE-IDENTITY
|
|
LAST-UPDATED "201201090000Z"
|
|
ORGANIZATION "Huawei Technologies Co.,Ltd."
|
|
CONTACT-INFO
|
|
"Huawei Industrial Base
|
|
Bantian, Longgang
|
|
Shenzhen 518129
|
|
People's Republic of China
|
|
Website: http://www.huawei.com
|
|
Email: support@huawei.com
|
|
"
|
|
DESCRIPTION "This MIB is used for defining Huawei's BTEST MIB objects,which
|
|
is used for Broad test.
|
|
"
|
|
|
|
-- Revision history
|
|
REVISION "201201090000Z"
|
|
DESCRIPTION "V3.14, modify the description of the leaf hwBTSSAdslSeltTestParamUnCalibLineScale, hwBTSSAdslSeltTestParamUnCalibEchoRespReal,
|
|
hwBTSSAdslSeltTestParamUnCalibEchoRespImg, hwBTSSAdslSeltTestParamCalibEchoRespReal, hwBTSSAdslSeltTestParamCalibEchoRespImg,
|
|
hwBTSSAdslSeltTestParamVarUerC, hwBTSSAdslSeltTestParamQSPsdValue, hwBTSSAdslSeltTestParamUpShnCap, hwBTSSAdslSeltTestParamAttnAt180KHZ,
|
|
hwBTSSAdslSeltTestParamAttnAt300KHZ, hwBTSSAdslSeltTestParamUerMmdC, hwBTSSAdslSeltTestParamQlnMmdC.
|
|
"
|
|
|
|
REVISION "201105040000Z"
|
|
DESCRIPTION "V3.13, add leaf node hwBTSSAdslSeltTestParamCalcEnable of hwBTSSAdslSeltTestTable for setting selt test calculation switch.
|
|
Add hwBTSSAdslSeltCalibrationTable for describing calibration data of selt test.
|
|
"
|
|
REVISION "201102220000Z"
|
|
DESCRIPTION "V3.12, changes in this revision:
|
|
modify the description of the leaf hwBTSSTestedPortOperMode,hwBTSSAdslSeltTestParamUmeC,
|
|
hwBTSSAdslSeltTestParamCalibLineScale,hwBTSSAdslSeltTestParamQmeC,
|
|
hwBTSSAdslSeltTestParamUnCalibLineScale,hwBTSSTestedPortOperMode.
|
|
"
|
|
|
|
REVISION "201102120000Z"
|
|
DESCRIPTION "V3.11, changes in this revision:
|
|
Add value resumeport(5) for hwBTSSTestedPortOperType.
|
|
"
|
|
|
|
REVISION "201010290000Z"
|
|
DESCRIPTION "V3.10, changes in this revision:
|
|
Add value -1(invalid) for hwBTSSAdslSeltLevel and modify the description.
|
|
"
|
|
|
|
REVISION "201009290000Z"
|
|
DESCRIPTION "V3.09, changes in this revision:
|
|
Add leaf node for new standard, include:
|
|
hwBTSSAdslSeltTestParamVarUerC
|
|
hwBTSSAdslSeltTestParamUerMmdC
|
|
hwBTSSAdslSeltTestParamQlnMmdC
|
|
hwBTSSAdslSeltTestParamUmeC
|
|
hwBTSSAdslSeltTestParamQmeC
|
|
hwBTSSAdslSeltTestParamUerStatus
|
|
hwBTSSAdslSeltTestParamQlnStatus
|
|
Modify the range of leaf node, include:
|
|
hwBTSSAdslSeltTestParamUnCalibLineScale
|
|
hwBTSSAdslSeltTestParamUnCalibEchoRespReal
|
|
hwBTSSAdslSeltTestParamUnCalibEchoRespImg
|
|
hwBTSSAdslSeltTestParamCalibLineScale
|
|
hwBTSSAdslSeltTestParamCalibEchoRespReal
|
|
hwBTSSAdslSeltTestParamCalibEchoRespImg
|
|
hwBTSSAdslSeltTestParamQSPsdValue
|
|
"
|
|
|
|
REVISION "201009270900Z"
|
|
DESCRIPTION "V3.08, changes in this revision:
|
|
modify the description of the hwBTSSCaptureTrap.
|
|
"
|
|
|
|
REVISION "201007120900Z"
|
|
DESCRIPTION "V3.07, changes in this revision:
|
|
Add value -1(invalid) for hwBTSSTestedPortOperType and six enumerate values for hwBTSSTestedPortOperMode
|
|
to support get operation.
|
|
"
|
|
|
|
REVISION "201006220900Z"
|
|
DESCRIPTION "V3.06, changes in this revision:
|
|
Modify chinese character.
|
|
"
|
|
|
|
REVISION "201003220000Z"
|
|
DESCRIPTION "V3.05, changes in this revision:
|
|
Add leaf node hwBTSSAdslSeltTestOperType of hwBTSSAdslSeltTestTable for setting or obtaining selt test
|
|
operation type.
|
|
Add leaf node hwBTSSAdslSeltTestParamLoopTermin of hwBTSSAdslSeltTestTable for obtaining selt test
|
|
parameter Loop Termination.
|
|
Add leaf node hwBTSSAdslSeltTestParamLoopGauge of hwBTSSAdslSeltTestTable for setting or obtaining selt
|
|
test parameter Loop Gauge.
|
|
Add leaf node hwBTSSAdslDeltTestOperType of hwBTSSAdslDeltTestTable for setting or obtaining delt test
|
|
operation type.
|
|
Modify MAX-ACCESS ,include:
|
|
hwBTSSAdslSeltTestParamAttnAt180KHZ
|
|
hwBTSSAdslSeltTestParamAttnAt300KHZ
|
|
hwBTSSAdslSeltTestParamQSPsdValue
|
|
"
|
|
|
|
REVISION "201002080000Z"
|
|
DESCRIPTION "V3.04, changes in this revision:
|
|
Delete the definition of the trap node,include:
|
|
hwBTSSCaptureTrap
|
|
hwBTSSSeltStartReplyTrap
|
|
hwBTSSSeltTestResultFirstFrameTrap
|
|
hwBTSSSeltTestResultSecondFrameTrap
|
|
hwBTSSSeltTestResultThirdFrameTrap
|
|
hwBTSSSeltTestResultFourFrameTrap
|
|
hwBTSSSeltTestResultFifthsFrameTrap
|
|
hwBTSSSeltTestResultSixthFrameTrap
|
|
hwBTSSSeltTestResultSeventhFrameTrap
|
|
"
|
|
|
|
REVISION "201001120000Z"
|
|
DESCRIPTION "V3.03, changes in this revision:
|
|
Add the definition of hwBTSSDeltResultDataTrap node.
|
|
"
|
|
|
|
REVISION "200906040900Z"
|
|
DESCRIPTION "V3.02, changes in this revision:
|
|
Add the definition of SYNTAX HWBTSSxDslLineOverLap, and change the SYNTAX from INTEGER to HWBTSSxDslLineOverLap
|
|
for hwBTSSxDslLineOverlapType of table hwBTSSxDslLineCfgTable
|
|
Add leaf hwBTSSCoTestBusyFlag into table hwBTSSCoTestTable OBJECT-TYPE
|
|
Add hwBTSSAuxPortCfgTable for describing aux port used for BTSS.
|
|
Add hwBTSSTestedPortOperTable for describing operation for tested port.
|
|
Add hwBTSSCqtTransTestTable for describeing CQT test by transparent command.
|
|
Add hwBTSSMultiFrameMiscOperTable for describing test relatived operation for multi-frame.
|
|
Add hwBTSSAdslSeltTestTable for describing selt test for adsl2+.
|
|
Add hwBTSSAdslDeltTestTable for describing Delt test for adsl2+.
|
|
Add hwBTSSLoopLineToneOprTable for Loop Line Tone.
|
|
Add leaf node hwBTSSTestedPortOperTrap for sending trap when tested port operation.
|
|
Add leaf node hwBTSSCqtTransTestOperResultTrap for sending trap when starting or stoping Cqt transparent test.
|
|
Add leaf node hwBTSSCqtTransTestResultTrap for sending trap when reporting the result after Cqt transparent test.
|
|
Add leaf node hwBTSSLoopLineToneOperTrap for sending trap when reporting the test result of Loop Line Tone.
|
|
|
|
Delete leafs hwBTSSxDslLineExtCrossMatrixRauModuleNo and wBTSSxDslLineExtCrossMatrixRauPortNo from table
|
|
Delete tables, include:
|
|
hwBTSSxDslLineCfgTable
|
|
hwBTSSCqtTemplateTable
|
|
hwBTSSCqtMaintainTable
|
|
hwBTSSCqtFrTestTable
|
|
hwBTSSCqtTdrTestTable
|
|
hwBTSSCqtDmtTestTable
|
|
hwBTSSCqtNseTestTable
|
|
hwBTSSCqtLbTestTable
|
|
hwBTSSCqtLcTestTable
|
|
hwBTSSCqtFrTestResultTable
|
|
hwBTSSCqtTdrTestResultTable
|
|
hwBTSSCqtDmtTestResultTable
|
|
hwBTSSCqtNseTestResultTable
|
|
hwBTSSCqtLbTestResultTable
|
|
hwBTSSCqtLcTestResultTable
|
|
Delete traps, include:
|
|
hwBTSSCqtFrTestTrap
|
|
hwBTSSCqtTdrTestTrap
|
|
hwBTSSCqtDmtTestTrap
|
|
hwBTSSCqtNseTestTrap
|
|
hwBTSSCqtLbTestTrap
|
|
hwBTSSCqtLcTestTrap
|
|
hwBTSSCqtStopFrTestTrap
|
|
hwBTSSCqtStopTdrTestTrap
|
|
hwBTSSCqtStopDmtTestTrap
|
|
hwBTSSCqtStopNseTestTrap
|
|
hwBTSSCqtStopLbTestTrap
|
|
hwBTSSCqtStopLcTestTrap
|
|
"
|
|
|
|
REVISION "200308280900Z"
|
|
DESCRIPTION "V3.00, change in this revision:
|
|
Change the style of description.
|
|
"
|
|
|
|
REVISION "200306280900Z"
|
|
DESCRIPTION "V2.00, change in this revision:
|
|
Correct the SYNTAX.
|
|
"
|
|
|
|
REVISION "200304280900Z"
|
|
DESCRIPTION "V1.00, initial version, by FixNet Mib Group."
|
|
::= { hwTest 3 }
|
|
|
|
HWBTSSxDslLineOverLap ::= TEXTUAL-CONVENTION
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Set overlap mode of xDSL with PSTN line.
|
|
Options:
|
|
1. overLap(1) - xDSL overlap with POTS line
|
|
2. direct(2) - There is no pots line, no splitter, no phone
|
|
3. unknown(3) - The mode is unknown
|
|
"
|
|
SYNTAX INTEGER
|
|
{
|
|
overLap(1),
|
|
direct(2),
|
|
unknown(3)
|
|
}
|
|
|
|
CqtQualitativeResultString ::= TEXTUAL-CONVENTION
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This string to contain qualitative result."
|
|
SYNTAX OCTET STRING (SIZE (0..255))
|
|
|
|
|
|
hwTest OBJECT IDENTIFIER ::= { huaweiUtility 21 }
|
|
|
|
hwBTestMib OBJECT IDENTIFIER ::= { hwBTest 1 }
|
|
|
|
hwBTestMIBObjects OBJECT IDENTIFIER ::= { hwBTestMib 1 }
|
|
|
|
hwBTSSxDslLineCfgTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF HwBTSSxDslLineCfgEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The hwBTSSxDslLineCfgTable table describes xDSL line configuration.
|
|
This table is used for bandwidth test.
|
|
The index of this table is ifIndex.
|
|
"
|
|
::= { hwBTestMIBObjects 1 }
|
|
|
|
hwBTSSxDslLineCfgEntry OBJECT-TYPE
|
|
SYNTAX HwBTSSxDslLineCfgEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The hwBTSSxDslLineCfgTable table describes xDSL line configuration.
|
|
This table is used for bandwidth test.
|
|
The index of this entry is ifIndex.
|
|
"
|
|
INDEX { ifIndex }
|
|
::= { hwBTSSxDslLineCfgTable 1 }
|
|
|
|
HwBTSSxDslLineCfgEntry ::=
|
|
SEQUENCE
|
|
{
|
|
hwBTSSxDslLineOverlapType HWBTSSxDslLineOverLap
|
|
}
|
|
|
|
hwBTSSxDslLineOverlapType OBJECT-TYPE
|
|
SYNTAX HWBTSSxDslLineOverLap
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Overlap mode of xDSL with PSTN line.
|
|
Options:
|
|
1. overLap(1) - xDSL overlap with POTS line
|
|
2. direct(2) - There is no pots line, no splitter, no phone
|
|
3. unknown(3) - The mode is unknown
|
|
Default: unknown(3)
|
|
"
|
|
DEFVAL { 3 }
|
|
::= { hwBTSSxDslLineCfgEntry 1 }
|
|
|
|
hwBTSSCoTestTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF HwBTSSCoTestEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"xDSL central office emulational measurement table.The table is used for xDSL central emulational measurement.
|
|
The index of this table is ifIndex.
|
|
"
|
|
::= { hwBTestMIBObjects 2 }
|
|
|
|
hwBTSSCoTestEntry OBJECT-TYPE
|
|
SYNTAX HwBTSSCoTestEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"xDSL central office emulational measurement table.The table is used for xDSL central emulational measurement.
|
|
The index of this entry is ifIndex.
|
|
"
|
|
INDEX { ifIndex }
|
|
::= { hwBTSSCoTestTable 1 }
|
|
|
|
HwBTSSCoTestEntry ::=
|
|
SEQUENCE
|
|
{
|
|
hwBTSSCoOperType
|
|
INTEGER,
|
|
hwBTSSCoTestResult
|
|
INTEGER,
|
|
hwBTSSCoTestBusyFlag
|
|
INTEGER
|
|
}
|
|
|
|
hwBTSSCoOperType OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
stop(1),
|
|
start(2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"CO emulational operation type.
|
|
Options:
|
|
1. stop(1) - Stop CO emulational
|
|
2. start(2) - Start CO emulational
|
|
"
|
|
::= { hwBTSSCoTestEntry 1 }
|
|
|
|
hwBTSSCoTestResult OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
normal(1),
|
|
testfail(2)
|
|
}
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"CO emulational test result.
|
|
Options:
|
|
1. normal(1) - The test of CO emulational is successful
|
|
2. testfail(2) - Fail in test of CO emulational
|
|
"
|
|
::= { hwBTSSCoTestEntry 2 }
|
|
|
|
hwBTSSCoTestBusyFlag OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
busyNoTest(1),
|
|
busyTest(2),
|
|
busystrenTest(3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"CO force test flag
|
|
Options:
|
|
1. busyNoTest(1) - No test on busy
|
|
2. busyTest(2) - Test on busy
|
|
3. busystrenTest(3) - Forced test on busy
|
|
"
|
|
::= { hwBTSSCoTestEntry 3 }
|
|
|
|
|
|
hwBTSSAuxPortCfgTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF HwBTSSAuxPortCfgEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Configuration table of the broadband test auxiliary port
|
|
This table is used to configure a certain type of emulation port required in the CO emulation test.
|
|
The indexes of this table are hwTestGroupNo and hwBTSSAuxPortType.
|
|
"
|
|
::= { hwBTestMIBObjects 17 }
|
|
|
|
hwBTSSAuxPortCfgEntry OBJECT-TYPE
|
|
SYNTAX HwBTSSAuxPortCfgEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Configuration table of the broadband test auxiliary port
|
|
This table is used to configure a certain type of emulation port required in the CO emulation test.
|
|
The indexes of this entry are hwTestGroupNo and hwBTSSAuxPortType.
|
|
"
|
|
INDEX { hwTestGroupNo, hwBTSSAuxPortType }
|
|
::= { hwBTSSAuxPortCfgTable 1 }
|
|
|
|
HwBTSSAuxPortCfgEntry ::=
|
|
SEQUENCE
|
|
{
|
|
hwBTSSAuxPortType INTEGER,
|
|
hwBTSSAuxPortIfIndex Integer32,
|
|
hwBTSSAuxPortRowStatus RowStatus
|
|
}
|
|
|
|
hwBTSSAuxPortType OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
adsl(1),
|
|
vdsl(2),
|
|
gshdsl(3)
|
|
}
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Assistance port type of BTSS.
|
|
Options:
|
|
1. adsl(1) - Assistance port type of BTSS is adsl
|
|
2. vdsl(2) - Assistance port type of BTSS is vdsl
|
|
3. gshdsl(3) - Assistance port type of BTSS is gshdsl
|
|
"
|
|
::= { hwBTSSAuxPortCfgEntry 1 }
|
|
|
|
hwBTSSAuxPortIfIndex OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Assistance port ifIndex of BTSS."
|
|
::= { hwBTSSAuxPortCfgEntry 2 }
|
|
|
|
hwBTSSAuxPortRowStatus OBJECT-TYPE
|
|
SYNTAX RowStatus
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Row status(add(4),delete(6))."
|
|
::= { hwBTSSAuxPortCfgEntry 3 }
|
|
|
|
hwBTSSTestedPortOperTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF HwBTSSTestedPortOperEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This table describes operation for tested port.
|
|
The index of this table is ifIndex.
|
|
"
|
|
::= { hwBTestMIBObjects 18 }
|
|
|
|
hwBTSSTestedPortOperEntry OBJECT-TYPE
|
|
SYNTAX HwBTSSTestedPortOperEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This table describes operation for tested port.
|
|
The index of this entry is ifIndex.
|
|
"
|
|
INDEX
|
|
{
|
|
ifIndex
|
|
}
|
|
::= { hwBTSSTestedPortOperTable 1 }
|
|
|
|
HwBTSSTestedPortOperEntry ::=
|
|
SEQUENCE
|
|
{
|
|
hwBTSSTestedPortOperType INTEGER,
|
|
hwBTSSTestedPortOperMode INTEGER,
|
|
hwBTSSTestedPortOperResult INTEGER,
|
|
hwBTSSTestedPortTestBusyFlag INTEGER,
|
|
hwBTSSTestedPortTestPOTSFlag INTEGER
|
|
}
|
|
|
|
hwBTSSTestedPortOperType OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
capture(1),
|
|
release(2),
|
|
startmonitor(3),
|
|
stopmonitor(4),
|
|
resumeport(5),
|
|
invalid(-1)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Operation type of BTSS tested port.
|
|
Options:
|
|
1. capture(1) - Capture
|
|
2. release(2) - Release
|
|
3. startmonitor(3) - Start monitor
|
|
4. stopmonitor(4) - Stop monitor
|
|
5. resumeport(5) - Resume port
|
|
6. invalid(-1) - Invalid value
|
|
"
|
|
::= { hwBTSSTestedPortOperEntry 1 }
|
|
|
|
hwBTSSTestedPortOperMode OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
inline(1),
|
|
outline(2),
|
|
monitor(3),
|
|
both(4),
|
|
meltNoCutxDSL(5),
|
|
meltForceCutxDSL(6),
|
|
testLineLoopback(7),
|
|
internalResistorLoopback(8),
|
|
passthroughmode(9)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Operation mode of BTSS tested port.
|
|
Options:
|
|
1. inline(1) - BTSS tested port in test
|
|
2. outline(2) - BTSS tested port out test
|
|
3. monitor(3) - Monitoring BTSS tested port
|
|
4. both(4) - Capture for circuit and loop-line test
|
|
5. meltNoCutxDSL(5) - Capture for melt chip test with co and cpe connecting
|
|
6. meltForceCutxDSL(6) - Capture for melt chip test with co and cpe disconnecting
|
|
7. testLineLoopback(7) - Capture for test line loopback
|
|
8. internalResistorLoopback(8) - Capture for internal resistor loopback
|
|
9. passthroughmode(9) - No capture
|
|
Default: passthroughmode(9)
|
|
"
|
|
::= { hwBTSSTestedPortOperEntry 2 }
|
|
|
|
hwBTSSTestedPortOperResult OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
normal(1),
|
|
fail(2),
|
|
timeout(4)
|
|
}
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Test result of BTSS tested port.
|
|
Options:
|
|
1. normal(1) - The test of BTSS tested port is successful
|
|
2. fail(2) - Fail in test of BTSS tested port
|
|
3. timeout(4) - The test of BTSS tested port is timeout
|
|
"
|
|
::= { hwBTSSTestedPortOperEntry 3 }
|
|
|
|
hwBTSSTestedPortTestBusyFlag OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
busyNoTest(1),
|
|
busyTest(2),
|
|
busystrenTest(3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Tested port force test.
|
|
Options:
|
|
1. busyNoTest(1) - No test on busy
|
|
2. busyTest(2) - Test on busy
|
|
3. busystrenTest(3) - Forced test on busy
|
|
"
|
|
::= { hwBTSSTestedPortOperEntry 4 }
|
|
|
|
hwBTSSTestedPortTestPOTSFlag OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
noCutPOTS(1),
|
|
busyNoTest(2),
|
|
busyTest(3),
|
|
busystrenTest(4)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Tested port POTS service flag
|
|
Options:
|
|
1. noCutPOTS(1) - No cut off POTS
|
|
2. busyNoTest(2) - No test on POTS busy (Cut off POTS)
|
|
3. busyTest(3) - Test on POTS busy (Cut off POTS)
|
|
4. busystrenTest(4) - Forced test on POTS busy (Cut off POTS)
|
|
"
|
|
::= { hwBTSSTestedPortOperEntry 5 }
|
|
|
|
hwBTSSCqtTransTestTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF HwBTSSCqtTransTestEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This table describes CQT test by transparent command.
|
|
The index of this table is ifIndex.
|
|
"
|
|
::= { hwBTestMIBObjects 19 }
|
|
|
|
hwBTSSCqtTransTestEntry OBJECT-TYPE
|
|
SYNTAX HwBTSSCqtTransTestEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This table describes CQT test by transparent command.
|
|
The index of this entry is ifIndex.
|
|
"
|
|
INDEX { ifIndex }
|
|
::= { hwBTSSCqtTransTestTable 1 }
|
|
|
|
HwBTSSCqtTransTestEntry ::=
|
|
SEQUENCE
|
|
{
|
|
hwBTSSCqtTransTestOperType INTEGER,
|
|
hwBTSSCqtTransTestCRCMode INTEGER,
|
|
hwBTSSCqtTransTestOperResult INTEGER,
|
|
hwBTSSCqtTransTestTxCmd OCTET STRING,
|
|
hwBTSSCqtTransTestResultNo Integer32,
|
|
hwBTSSCqtTransTestResultLastFlag INTEGER,
|
|
hwBTSSCqtTransTestResult OCTET STRING
|
|
}
|
|
|
|
hwBTSSCqtTransTestOperType OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
stop(1),
|
|
start(2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"CQT transparent Operation type
|
|
Options:
|
|
1. stop(1) - Stop CQT transparent test
|
|
2. start(2) - Start CQT transparent test
|
|
"
|
|
::= { hwBTSSCqtTransTestEntry 1 }
|
|
|
|
hwBTSSCqtTransTestCRCMode OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
disable(1),
|
|
enable(2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"CRC Operation type of CQT transparent.
|
|
Options:
|
|
1. disable(1) - Disable CQT transparent
|
|
2. enable(2) - Enable CQT transparent
|
|
Default: disable(1)
|
|
"
|
|
DEFVAL { 1 }
|
|
::= { hwBTSSCqtTransTestEntry 2 }
|
|
|
|
hwBTSSCqtTransTestOperResult OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
normal(1),
|
|
fail(2),
|
|
abort(3),
|
|
powerfeed(4)
|
|
}
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"CQT transparent Operation result.
|
|
Options:
|
|
1. normal(1) - The CQT transparent test is successful
|
|
2. fail(2) - The CQT transparent test fails
|
|
3. abort(3) - The CQT transparent test aborts
|
|
4. powerfeed(4) - The CQT transparent test power feeds
|
|
"
|
|
::= { hwBTSSCqtTransTestEntry 3 }
|
|
|
|
hwBTSSCqtTransTestTxCmd OBJECT-TYPE
|
|
SYNTAX OCTET STRING(SIZE(0..251))
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Sending command string in TL1 format."
|
|
::= { hwBTSSCqtTransTestEntry 4 }
|
|
|
|
hwBTSSCqtTransTestResultNo OBJECT-TYPE
|
|
SYNTAX Integer32(1..255)
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Test result No.
|
|
Range: 1-255
|
|
"
|
|
::= { hwBTSSCqtTransTestEntry 5 }
|
|
|
|
hwBTSSCqtTransTestResultLastFlag OBJECT-TYPE
|
|
SYNTAX INTEGER{false(0), true(1)}
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Last package flag for test result.
|
|
Options:
|
|
1. false(0) - This is not the last package
|
|
2. true(1) - The last package
|
|
"
|
|
::= { hwBTSSCqtTransTestEntry 6 }
|
|
|
|
hwBTSSCqtTransTestResult OBJECT-TYPE
|
|
SYNTAX OCTET STRING(SIZE(0..231))
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"CQT transparent Test result."
|
|
::= { hwBTSSCqtTransTestEntry 7 }
|
|
|
|
|
|
hwBTSSMultiFrameMiscOperTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF HwBTSSMultiFrameMiscOperEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This table describes test relatived operation for multi-frame.
|
|
The index of this table is ifIndex.
|
|
"
|
|
::= { hwBTestMIBObjects 20 }
|
|
|
|
hwBTSSMultiFrameMiscOperEntry OBJECT-TYPE
|
|
SYNTAX HwBTSSMultiFrameMiscOperEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This table describes test relatived operation for multi-frame.
|
|
The index of this entry is ifIndex.
|
|
"
|
|
INDEX
|
|
{
|
|
ifIndex
|
|
}
|
|
::= { hwBTSSMultiFrameMiscOperTable 1 }
|
|
|
|
HwBTSSMultiFrameMiscOperEntry ::=
|
|
SEQUENCE
|
|
{
|
|
hwBTSSMultiFrameMiscCleanTest INTEGER,
|
|
hwBTSSMultiFrameMiscTestedFrame Integer32,
|
|
hwBTSSMultiFrameMiscTestedPortType HWPortType,
|
|
hwBTSSMultiFrameMiscTestedLineType HWBTSSxDslLineOverLap
|
|
}
|
|
|
|
hwBTSSMultiFrameMiscCleanTest OBJECT-TYPE
|
|
SYNTAX INTEGER{start(1)}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Clean current test on specified frame.
|
|
Options:
|
|
1. start(1) - Start clean current test
|
|
"
|
|
::= { hwBTSSMultiFrameMiscOperEntry 1 }
|
|
|
|
hwBTSSMultiFrameMiscTestedFrame OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Tested frame of BTSS multi-frame.
|
|
Default: 0
|
|
"
|
|
DEFVAL { 0 }
|
|
::= { hwBTSSMultiFrameMiscOperEntry 2 }
|
|
|
|
hwBTSSMultiFrameMiscTestedPortType OBJECT-TYPE
|
|
SYNTAX HWPortType
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Tested port type of BTSS multi-frame."
|
|
::= { hwBTSSMultiFrameMiscOperEntry 3 }
|
|
|
|
hwBTSSMultiFrameMiscTestedLineType OBJECT-TYPE
|
|
SYNTAX HWBTSSxDslLineOverLap
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Tested line type of BTSS multi-frame."
|
|
::= { hwBTSSMultiFrameMiscOperEntry 4 }
|
|
|
|
hwBTSSAdslSeltTestTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF HWBTSSAdslSeltTestEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This table describes selt test for adsl2+.
|
|
The index of this table is ifIndex.
|
|
"
|
|
::= { hwBTestMIBObjects 21 }
|
|
hwBTSSAdslSeltTestEntry OBJECT-TYPE
|
|
SYNTAX HWBTSSAdslSeltTestEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This table describes selt test for adsl2+.
|
|
The index of this entry is ifIndex.
|
|
"
|
|
INDEX
|
|
{
|
|
ifIndex
|
|
}
|
|
::= { hwBTSSAdslSeltTestTable 1 }
|
|
|
|
HWBTSSAdslSeltTestEntry ::=
|
|
SEQUENCE
|
|
{
|
|
hwBTSSAdslSeltTestOperType INTEGER ,
|
|
hwBTSSAdslSeltTestOperResult INTEGER ,
|
|
hwBTSSAdslSeltTestResultNo Integer32 ,
|
|
hwBTSSAdslSeltTestResultLastFlag INTEGER ,
|
|
hwBTSSAdslSeltTestResult OCTET STRING ,
|
|
hwBTSSAdslSeltTestParamLoopLength Integer32 ,
|
|
hwBTSSAdslSeltTestParamLoopTermin INTEGER ,
|
|
hwBTSSAdslSeltTestParamLoopGauge INTEGER ,
|
|
hwBTSSAdslSeltTestParamUpShnCap Integer32 ,
|
|
hwBTSSAdslSeltTestParamDwnShnCap Integer32 ,
|
|
hwBTSSAdslSeltTestParamInbandNoise OCTET STRING ,
|
|
hwBTSSAdslSeltTestParamTerminResp OCTET STRING ,
|
|
hwBTSSAdslSeltTestParamUpMgnAtRate OCTET STRING ,
|
|
hwBTSSAdslSeltTestParamDwnMgnAtRate OCTET STRING ,
|
|
hwBTSSAdslSeltTestParamUpRateAtMgn OCTET STRING ,
|
|
hwBTSSAdslSeltTestParamDwnRateAtMgn OCTET STRING ,
|
|
hwBTSSAdslSeltTestParamLoopAttenAtFreq OCTET STRING,
|
|
hwBTSSAdslSeltTestParamUnCalibLineScale Unsigned32,
|
|
hwBTSSAdslSeltTestParamUnCalibEchoRespReal OCTET STRING,
|
|
hwBTSSAdslSeltTestParamUnCalibEchoRespImg OCTET STRING,
|
|
hwBTSSAdslSeltTestParamCalibLineScale Unsigned32,
|
|
hwBTSSAdslSeltTestParamCalibEchoRespReal OCTET STRING,
|
|
hwBTSSAdslSeltTestParamCalibEchoRespImg OCTET STRING,
|
|
hwBTSSAdslSeltTestParamVarUerC OCTET STRING,
|
|
hwBTSSAdslSeltTestParamUerMmdC Unsigned32,
|
|
hwBTSSAdslSeltTestParamQlnMmdC Unsigned32,
|
|
hwBTSSAdslSeltTestParamUmeC INTEGER,
|
|
hwBTSSAdslSeltTestParamQmeC INTEGER,
|
|
hwBTSSAdslSeltTestParamUerStatus INTEGER,
|
|
hwBTSSAdslSeltTestParamQlnStatus INTEGER,
|
|
hwBTSSAdslSeltTestParamCalcEnable INTEGER,
|
|
hwBTSSAdslSeltTestParamAttnAt180KHZ Integer32,
|
|
hwBTSSAdslSeltTestParamAttnAt300KHZ Integer32,
|
|
hwBTSSAdslSeltTestParamQSPsdValue OCTET STRING
|
|
}
|
|
|
|
hwBTSSAdslSeltTestOperType OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
stop(1),
|
|
start(2),
|
|
invalid(-1)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Selt test operation type.
|
|
Options:
|
|
1. stop(1) - Stop selt test of BTSS
|
|
2. start(2) - Start selt test of BTSS
|
|
3. invalid(-1) - No operation
|
|
"
|
|
::= { hwBTSSAdslSeltTestEntry 1 }
|
|
hwBTSSAdslSeltTestOperResult OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
normal(1),
|
|
fail(2),
|
|
abort(3)
|
|
}
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Selt test operation result.
|
|
Options:
|
|
1. normal(1) - Selt test of BTSS is successful
|
|
2. fail(2) - Fail in selt test of BTSS
|
|
3. abort(3) - Selt test of BTSS aborts
|
|
"
|
|
::= { hwBTSSAdslSeltTestEntry 2 }
|
|
hwBTSSAdslSeltTestResultNo OBJECT-TYPE
|
|
SYNTAX Integer32(1..255)
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Selt test result serial number.
|
|
Range: 1-255
|
|
"
|
|
::= { hwBTSSAdslSeltTestEntry 3 }
|
|
hwBTSSAdslSeltTestResultLastFlag OBJECT-TYPE
|
|
SYNTAX INTEGER{false(0), true(1)}
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Last package flag of test.
|
|
Options:
|
|
1. false(0) - This is not the last package
|
|
2. true(1) - The last package
|
|
"
|
|
::= { hwBTSSAdslSeltTestEntry 4 }
|
|
hwBTSSAdslSeltTestResult OBJECT-TYPE
|
|
SYNTAX OCTET STRING(SIZE(0..1500))
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Selt test result data."
|
|
::= { hwBTSSAdslSeltTestEntry 5 }
|
|
hwBTSSAdslSeltTestParamLoopLength OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Selt test parameter Loop Length.
|
|
The invalid value is -1. If no SELT is performed, no SELT data is
|
|
generated because the SELT is incomplete, or no SELT data can be
|
|
obtained from the port because the SELT data is aged and cleared,
|
|
the invalid value will be returned."
|
|
::= { hwBTSSAdslSeltTestEntry 6 }
|
|
hwBTSSAdslSeltTestParamLoopTermin OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
open(0),
|
|
short(1),
|
|
unknow(2),
|
|
terminated(3),
|
|
invalid(-1)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Selt test parameter Loop Termination state.
|
|
Options:
|
|
1. open(0) - Indicates that the line terminal is started
|
|
2. short(1) - Indicates that the line terminal is short-circuited
|
|
3. unknow(2) - Indicates the unknown state
|
|
4. terminated(3) - Indicates that the line terminal is stopped
|
|
5. invalid(-1) - Indicates the invalid state
|
|
"
|
|
::= { hwBTSSAdslSeltTestEntry 7 }
|
|
hwBTSSAdslSeltTestParamLoopGauge OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
greater26awg(1),
|
|
equal26awg(2),
|
|
equal24awg(3),
|
|
less24awg(4),
|
|
unknowawg(5),
|
|
invalid(-1)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Selt test parameter Loop Gauge.
|
|
Options:
|
|
1. greater26awg(1) - Indicates that the line gauge is greater than 26
|
|
2. equal26awg(2) - Indicates that the line gauge is 26
|
|
3. equal24awg(3) - Indicates that the line gauge is 24
|
|
4. less24awg(4) - Indicates that the line gauge is smaller than 24
|
|
5. unknowawg(5) - Indicates an unknown line gauge.
|
|
6. invalid(-1) - Indicates an invalid value.
|
|
"
|
|
::= { hwBTSSAdslSeltTestEntry 8 }
|
|
hwBTSSAdslSeltTestParamUpShnCap OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Selt test parameter Upstream Shannon Capacity.
|
|
The invalid value is -1. If no SELT is performed, no SELT data is
|
|
generated because the SELT is incomplete, or no SELT data can be
|
|
obtained from the port because the SELT data is aged and cleared,
|
|
the invalid value will be returned."
|
|
::= { hwBTSSAdslSeltTestEntry 9 }
|
|
hwBTSSAdslSeltTestParamDwnShnCap OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Selt test parameter Downstream Shannon Capacity."
|
|
::= { hwBTSSAdslSeltTestEntry 10 }
|
|
hwBTSSAdslSeltTestParamInbandNoise OBJECT-TYPE
|
|
SYNTAX OCTET STRING(SIZE(0..1500))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Selt test parameter Inband Noise
|
|
512 values that indicate inband noise in dBm/Hz,
|
|
covering ADSL, ADSL2, and ADSL2+ bands, from 0 to 2.2 MHz.
|
|
"
|
|
::= { hwBTSSAdslSeltTestEntry 11 }
|
|
hwBTSSAdslSeltTestParamTerminResp OBJECT-TYPE
|
|
SYNTAX OCTET STRING(SIZE(0..1500))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Selt test parameter Termination Response
|
|
180 values that indicate termination response magnitude from 0 to 18 kft.
|
|
"
|
|
::= { hwBTSSAdslSeltTestEntry 12 }
|
|
hwBTSSAdslSeltTestParamUpMgnAtRate OBJECT-TYPE
|
|
SYNTAX OCTET STRING(SIZE(0..1500))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Selt test parameter Upstream Ratevs. Margin.
|
|
This value is a measure of the quality of your upstream data
|
|
signal relative to the noise on the line. Hundreds of values that
|
|
indicate SNR margin in DB/Hz at a particular bit rate are provided,
|
|
at a certain increments, up to 30 Mbps. This information may be plotted
|
|
with the bit rate on the X-axis and the SNR margin on the Y-axis.
|
|
"
|
|
::= { hwBTSSAdslSeltTestEntry 13 }
|
|
|
|
hwBTSSAdslSeltTestParamDwnMgnAtRate OBJECT-TYPE
|
|
SYNTAX OCTET STRING(SIZE(0..1500))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Selt test parameter Downstream Rate vs. Margin.
|
|
This value is a measure of the quality of your downstream data
|
|
signal relative to the noise on the line. Hundreds of values that
|
|
indicate SNR margin in DB/Hz at a particular bit rate are provided,
|
|
at a certain increments, up to 30 Mbps. This information may be plotted
|
|
with the bit rate on the X-axis and the SNR margin on the Y-axis.
|
|
"
|
|
::= { hwBTSSAdslSeltTestEntry 14 }
|
|
|
|
hwBTSSAdslSeltTestParamUpRateAtMgn OBJECT-TYPE
|
|
SYNTAX OCTET STRING(SIZE(0..1500))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Selt test parameter Upstream Margin vs. Rate."
|
|
::= { hwBTSSAdslSeltTestEntry 15 }
|
|
|
|
hwBTSSAdslSeltTestParamDwnRateAtMgn OBJECT-TYPE
|
|
SYNTAX OCTET STRING(SIZE(0..1500))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Selt test parameter Downstream Margin vs. Rate."
|
|
::= { hwBTSSAdslSeltTestEntry 16 }
|
|
|
|
hwBTSSAdslSeltTestParamLoopAttenAtFreq OBJECT-TYPE
|
|
SYNTAX OCTET STRING(SIZE(0..2048))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Selt test parameter loop attenuation versus frequency.
|
|
Every four bytes constitute the result of a tone.
|
|
This information may be plotted with the bit frequency
|
|
on the X-axis and the loop attenuation on the Y-axis.
|
|
"
|
|
::= { hwBTSSAdslSeltTestEntry 17 }
|
|
|
|
hwBTSSAdslSeltTestParamUnCalibLineScale OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The uncalibrated echo response, UER(i* UER_G*Df), shall be represented in linear format by a
|
|
scale factor and a normalized complex number a(i)+j*b(i), where i is a frequency index i ranging
|
|
from 0 to NSC-1, the subcarrier spacing, Df = 4.3125 kHz, and (NSC-1) * UER_G * Df is the
|
|
highest frequency supported by the SELT-PMD functionality. The UER granularity parameter,
|
|
UER_G, has two valid values: 1 and 2, indicating whether the measurements were performed using
|
|
a tone spacing of 4.3125 kHz or of 8.625 kHz. If the uncalibrated echo response is being reported
|
|
over a frequency range of 17.664 MHz or lower, UER_G shall be set to 1. If the uncalibrated echo
|
|
response is being reported over a frequency range that is greater than 17.664 MHz, UER_G shall be
|
|
set to 2.
|
|
The scale factor shall be coded as a 32-bit unsigned integer. Both a(i) and b(i) shall be coded as
|
|
32-bit 2's complement signed integers. The value of UER(i* UER_G*Df) shall be defined as:
|
|
UER(i* UER_G*Df) = (scale/2^31)*(a(i)+j*b(i))/2^31. In order to maximize precision, the scale factor
|
|
shall be chosen such that max(|a(i)|, |b(i)|) over all i is equal to 2^31-1.
|
|
NOTE - This data format supports an UER(f) granularity of 2^-31 and an UER(f) dynamic range of
|
|
approximately +6 dB to -186 dB, however it does not imply any future accuracy requirements.
|
|
An UER(i*UER_G* Df) value indicated as a(i) = b(i) = -2^31 is a special value. It indicates that no
|
|
measurement could be done for this subcarrier either because it is not supported by the SELT-PMD
|
|
function, or that the value is out of range to be represented.
|
|
"
|
|
::= { hwBTSSAdslSeltTestEntry 18 }
|
|
|
|
hwBTSSAdslSeltTestParamUnCalibEchoRespReal OBJECT-TYPE
|
|
SYNTAX OCTET STRING(SIZE(0..2048))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The uncalibrated echo response, UER(i* UER_G*Df), shall be represented in linear format by a
|
|
scale factor and a normalized complex number a(i)+j*b(i), where i is a frequency index i ranging
|
|
from 0 to NSC-1, the subcarrier spacing, Df = 4.3125 kHz, and (NSC-1) * UER_G * Df is the
|
|
highest frequency supported by the SELT-PMD functionality. The UER granularity parameter,
|
|
UER_G, has two valid values: 1 and 2, indicating whether the measurements were performed using
|
|
a tone spacing of 4.3125 kHz or of 8.625 kHz. If the uncalibrated echo response is being reported
|
|
over a frequency range of 17.664 MHz or lower, UER_G shall be set to 1. If the uncalibrated echo
|
|
response is being reported over a frequency range that is greater than 17.664 MHz, UER_G shall be
|
|
set to 2.
|
|
The scale factor shall be coded as a 32-bit unsigned integer. Both a(i) and b(i) shall be coded as
|
|
32-bit 2's complement signed integers. The value of UER(i* UER_G*Df) shall be defined as:
|
|
UER(i* UER_G*Df) = (scale/2^31)*(a(i)+j*b(i))/2^31. In order to maximize precision, the scale factor
|
|
shall be chosen such that max(|a(i)|, |b(i)|) over all i is equal to 2^31-1.
|
|
NOTE - This data format supports an UER(f) granularity of 2^-31 and an UER(f) dynamic range of
|
|
approximately +6 dB to -186 dB, however it does not imply any future accuracy requirements.
|
|
An UER(i*UER_G* Df) value indicated as a(i) = b(i) = -2^31 is a special value. It indicates that no
|
|
measurement could be done for this subcarrier either because it is not supported by the SELT-PMD
|
|
function, or that the value is out of range to be represented.
|
|
"
|
|
::= { hwBTSSAdslSeltTestEntry 19 }
|
|
|
|
hwBTSSAdslSeltTestParamUnCalibEchoRespImg OBJECT-TYPE
|
|
SYNTAX OCTET STRING(SIZE(0..2048))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The uncalibrated echo response, UER(i* UER_G*Df), shall be represented in linear format by a
|
|
scale factor and a normalized complex number a(i)+j*b(i), where i is a frequency index i ranging
|
|
from 0 to NSC-1, the subcarrier spacing, Df = 4.3125 kHz, and (NSC-1) * UER_G * Df is the
|
|
highest frequency supported by the SELT-PMD functionality. The UER granularity parameter,
|
|
UER_G, has two valid values: 1 and 2, indicating whether the measurements were performed using
|
|
a tone spacing of 4.3125 kHz or of 8.625 kHz. If the uncalibrated echo response is being reported
|
|
over a frequency range of 17.664 MHz or lower, UER_G shall be set to 1. If the uncalibrated echo
|
|
response is being reported over a frequency range that is greater than 17.664 MHz, UER_G shall be
|
|
set to 2.
|
|
The scale factor shall be coded as a 32-bit unsigned integer. Both a(i) and b(i) shall be coded as
|
|
32-bit 2's complement signed integers. The value of UER(i* UER_G*Df) shall be defined as:
|
|
UER(i* UER_G*Df) = (scale/2^31)*(a(i)+j*b(i))/2^31. In order to maximize precision, the scale factor
|
|
shall be chosen such that max(|a(i)|, |b(i)|) over all i is equal to 2^31-1.
|
|
NOTE - This data format supports an UER(f) granularity of 2^-31 and an UER(f) dynamic range of
|
|
approximately +6 dB to -186 dB, however it does not imply any future accuracy requirements.
|
|
An UER(i*UER_G* Df) value indicated as a(i) = b(i) = -2^31 is a special value. It indicates that no
|
|
measurement could be done for this subcarrier either because it is not supported by the SELT-PMD
|
|
function, or that the value is out of range to be represented.
|
|
"
|
|
::= { hwBTSSAdslSeltTestEntry 20 }
|
|
|
|
hwBTSSAdslSeltTestParamCalibLineScale OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The scale factor of calibrated echo response shall be coded as a 16 bit
|
|
unsigned integer.
|
|
"
|
|
::= { hwBTSSAdslSeltTestEntry 21 }
|
|
|
|
hwBTSSAdslSeltTestParamCalibEchoRespReal OBJECT-TYPE
|
|
SYNTAX OCTET STRING(SIZE(0..2048))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The calibrated echo response UER(i* f), shall be represented
|
|
in linear format by a scale factor and a normalized complex number a(i)+j*b(i),
|
|
where i is the subcarrier index i ranging from 0 to NSC-1 and Df = 4.3125kHz
|
|
and (NSC-1) * Df is the highest frequency supported by the SELT-PMD functionality.
|
|
The scale factor shall be coded as a 16 bit unsigned integer.
|
|
Both a(i) and b(i) shall be coded as a 16 bit 2's complement signed integer.
|
|
The value of UER(i* f) shall be defined as UER(i* f) = (scale/215)*(a(i)+j*b(i))/215.
|
|
In order to maximize precision, the scale factor shall be chosen such that max(|a(i)|, |b(i)|)
|
|
over all i is equal to 215-1. This data format supports an UER(f) granularity of 2-15
|
|
and an UER(f) dynamic range of approximately +6 dB to -90 dB.
|
|
An UER(i*Df) value indicated as a(i) = b(i) = -215 is a special value.
|
|
It indicates that no measurement could be done for this subcarrier because
|
|
it is out of the PSD mask passband or that the value is out of range to be represented.
|
|
"
|
|
::= { hwBTSSAdslSeltTestEntry 22 }
|
|
|
|
hwBTSSAdslSeltTestParamCalibEchoRespImg OBJECT-TYPE
|
|
SYNTAX OCTET STRING(SIZE(0..2048))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The calibrated echo response UER(i* f), shall be represented
|
|
in linear format by a scale factor and a normalized complex number a(i)+j*b(i),
|
|
where i is the subcarrier index i ranging from 0 to NSC-1 and Df = 4.3125kHz
|
|
and (NSC-1) * Df is the highest frequency supported by the SELT-PMD functionality.
|
|
The scale factor shall be coded as a 16 bit unsigned integer.
|
|
Both a(i) and b(i) shall be coded as a 16 bit 2's complement signed integer.
|
|
The value of UER(i* f) shall be defined as UER(i* f) = (scale/215)*(a(i)+j*b(i))/215.
|
|
In order to maximize precision, the scale factor shall be chosen such that max(|a(i)|, |b(i)|)
|
|
over all i is equal to 215-1. This data format supports an UER(f) granularity of 2-15
|
|
and an UER(f) dynamic range of approximately +6 dB to -90 dB.
|
|
An UER(i*Df) value indicated as a(i) = b(i) = -215 is a special value.
|
|
It indicates that no measurement could be done for this subcarrier because
|
|
it is out of the PSD mask passband or that the value is out of range to be represented.
|
|
"
|
|
::= { hwBTSSAdslSeltTestEntry 23 }
|
|
|
|
hwBTSSAdslSeltTestParamVarUerC OBJECT-TYPE
|
|
SYNTAX OCTET STRING(SIZE(0..2048))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The relative variance of the uncalibrated echo response REL_VAR_UER(i* UER_G *Df) shall be
|
|
represented as an 8-bit unsigned integer v(i), where i is the subcarrier index i = 0 to NSC-1. The
|
|
value of REL_VAR_UER(i* UER_G *Df) shall be defined as REL_VAR_UER(i* UER_G *Df) = 3 - v(i)/2 dB.
|
|
The number v(i) is an 8-bit unsigned integer in the range 0 to 254.
|
|
This data format supports a REL_VAR_UER(i) over a range from -124 dB to +3 dB for each carrier with a granularity from 0.5 dB.
|
|
Out of range values shall be clamped to the closest range bound.
|
|
The special value v(i) = 255 indicates that no measurement is available for that carrier.
|
|
Unit: 0.5dB
|
|
"
|
|
::= { hwBTSSAdslSeltTestEntry 24 }
|
|
|
|
hwBTSSAdslSeltTestParamUerMmdC OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This parameter is the maximum allowed time for SELT uncalibrated echo response measurement,
|
|
between the time of the start command written by the SELT-PMD-ME, and the time the result is
|
|
available for read operation by SELT-PMD-ME.
|
|
It is configurable between 5 seconds and 240 seconds, in steps of 1 second.
|
|
The invalid value is 255. If data on the port cannot be queried, the invalid value will be returned.
|
|
Unit: 1 second
|
|
"
|
|
::= { hwBTSSAdslSeltTestEntry 25 }
|
|
|
|
hwBTSSAdslSeltTestParamQlnMmdC OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This parameter is the maximum allowed time for SELT quiet line noise measurement, between the
|
|
time of the start command written by the SELT-PMD-ME, and the time the result is available for
|
|
read operation by SELT-PMD-ME.
|
|
It is configurable between 1 second and 240 seconds, in steps of 1 second.
|
|
The invalid value is 255. If data on the port cannot be queried, the invalid value will be returned.
|
|
Unit: 1 second
|
|
"
|
|
::= { hwBTSSAdslSeltTestEntry 26 }
|
|
|
|
hwBTSSAdslSeltTestParamUmeC OBJECT-TYPE
|
|
SYNTAX INTEGER{enable(1),disable(2),invalid(-1)}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This parameter is a binary variable.
|
|
Options:
|
|
1.enable(1) - Enable UER capture switch
|
|
2.disable(2) - Disable UER capture switch
|
|
3.invalid(-1) - Invalid value
|
|
"
|
|
::= { hwBTSSAdslSeltTestEntry 27 }
|
|
|
|
hwBTSSAdslSeltTestParamQmeC OBJECT-TYPE
|
|
SYNTAX INTEGER{enable(1),disable(2),invalid(-1)}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This parameter is a binary variable.
|
|
Options:
|
|
1.enable(1) - Enable QLN capture switch
|
|
2.disable(2) - Disable QLN capture switch
|
|
3.invalid(-1) - Invalid value
|
|
"
|
|
::= { hwBTSSAdslSeltTestEntry 28 }
|
|
|
|
hwBTSSAdslSeltTestParamUerStatus OBJECT-TYPE
|
|
SYNTAX INTEGER{off(1), running(2),completed(3),failed(4)}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"UerStatus.
|
|
Options:
|
|
1.off(1) - The status is off.
|
|
2.running(2) - The status is running.
|
|
3.completed(3) - The status is completed.
|
|
4.failed(4) - The status is failed.
|
|
"
|
|
::= { hwBTSSAdslSeltTestEntry 29 }
|
|
|
|
hwBTSSAdslSeltTestParamQlnStatus OBJECT-TYPE
|
|
SYNTAX INTEGER{off(1), running(2),completed(3),failed(4)}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"QlnStatus.
|
|
Options:
|
|
1.off(1) - The status is off.
|
|
2.running(2) - The status is running.
|
|
3.completed(3) - The status is completed.
|
|
4.failed(4) - The status is failed.
|
|
"
|
|
::= { hwBTSSAdslSeltTestEntry 30 }
|
|
|
|
hwBTSSAdslSeltTestParamCalcEnable OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
enable(1),
|
|
disable(2),
|
|
invalid(-1)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The status of calculation switch.
|
|
Options:
|
|
1. enable(1) - Enable calculation switch
|
|
2. disable(2) - Disable calculation switch
|
|
3. invalid(-1) - Invalid value
|
|
Default: enable(1)
|
|
"
|
|
DEFVAL { enable }
|
|
::= { hwBTSSAdslSeltTestEntry 31 }
|
|
|
|
hwBTSSAdslSeltTestParamAttnAt180KHZ OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1dB"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Selt test parameter attenuation at 180KHZ.
|
|
It ranges from -1100 to 0 units of 0.1dB(physical values
|
|
are -110 to 0 dB).
|
|
The invalid value is -1. If no SELT is performed, no SELT data is
|
|
generated because the SELT is incomplete, or no SELT data can be
|
|
obtained from the port because the SELT data is aged and cleared,
|
|
the invalid value will be returned.
|
|
Unit: 0.1dB
|
|
"
|
|
::= { hwBTSSAdslSeltTestEntry 65535 }
|
|
|
|
hwBTSSAdslSeltTestParamAttnAt300KHZ OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1dB"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Selt test parameter attenuation at 300KHZ.
|
|
It ranges from -1100 to 0 units of 0.1dB(physical values
|
|
are -110 to 0 dB).
|
|
The invalid value is -1. If no SELT is performed, no SELT data is
|
|
generated because the SELT is incomplete, or no SELT data can be
|
|
obtained from the port because the SELT data is aged and cleared,
|
|
the invalid value will be returned.
|
|
Unit: 0.1dB
|
|
"
|
|
::= { hwBTSSAdslSeltTestEntry 65536 }
|
|
|
|
hwBTSSAdslSeltTestParamQSPsdValue OBJECT-TYPE
|
|
SYNTAX OCTET STRING(SIZE(0..1024))
|
|
UNITS "0.5dBm/Hz"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The SELT quiet line noise provides the quiet line noise PSD as measured by the SELT-PMD
|
|
function (see clause A.1.1.2) for each sub-carrier frequency i * SELTQLN_G * Df where i ranges
|
|
from 0 to NSC-1, Df = 4.3125 kHz, and (NSC-1) * SELTQLN_G * Df is the highest frequency
|
|
supported by the SELT-PMD functionality. SELTQLN_G has two valid values: 1 and 2, indicating
|
|
whether the measurements were performed using a tone spacing of 4.3125 kHz or of 8.625 kHz. If
|
|
the SELT quiet line noise is being reported over a frequency range of 17.664 MHz or lower,
|
|
SELTQLN_G shall be set to 1. If the SELT quiet line noise is being reported over a frequency
|
|
range that is greater than 17.664 MHz, SELTQLN_G shall be set to 2.
|
|
SELT quiet line noise SELTQLN(i * SELTQLN_G * Df) shall be represented as an 8-bit unsigned
|
|
integer n(i), where i is the subcarrier index i = 0 to NSC-1. The value of
|
|
SELTQLN(i * SELTQLN_G * Df) shall be defined as SELTQLN(i * SELTQLN_G * Df ) =
|
|
-23 - (n(i)/2) dBm/Hz. This data format supports a SELTQLN(f) granularity of 0.5 dB and an
|
|
SELTQLN(f) dynamic range of -150 to -23 dBm/Hz.
|
|
Unit: 0.5dBm/Hz
|
|
"
|
|
::= { hwBTSSAdslSeltTestEntry 65537 }
|
|
|
|
hwBTSSAdslDeltTestTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF HWBTSSAdslDeltTestEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This table describes Delt test for adsl2+.
|
|
The index of this table is ifIndex.
|
|
"
|
|
::= { hwBTestMIBObjects 22 }
|
|
hwBTSSAdslDeltTestEntry OBJECT-TYPE
|
|
SYNTAX HWBTSSAdslDeltTestEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This table describes Delt test for adsl2+.
|
|
The index of this entry is ifIndex.
|
|
"
|
|
INDEX
|
|
{
|
|
ifIndex
|
|
}
|
|
::= { hwBTSSAdslDeltTestTable 1 }
|
|
|
|
HWBTSSAdslDeltTestEntry ::=
|
|
SEQUENCE
|
|
{
|
|
hwBTSSAdslDeltTestOperType INTEGER ,
|
|
hwBTSSAdslDeltTestOperResult INTEGER ,
|
|
hwBTSSAdslDeltTestResultNo Integer32 ,
|
|
hwBTSSAdslDeltTestResultLastFlag INTEGER ,
|
|
hwBTSSAdslDeltTestResult OCTET STRING
|
|
}
|
|
|
|
hwBTSSAdslDeltTestOperType OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
stop(1),
|
|
start(2),
|
|
invalid(-1)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Delt test operation type.
|
|
Options:
|
|
1. stop(1) - Delt test stop
|
|
2. start(2) - Start delt test
|
|
3. invalid(-1) - No operation
|
|
"
|
|
::= { hwBTSSAdslDeltTestEntry 1 }
|
|
hwBTSSAdslDeltTestOperResult OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
normal(1),
|
|
fail(2),
|
|
abort(3)
|
|
}
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Delt test operation result.
|
|
Options:
|
|
1. normal(1) - Delt test is normal
|
|
2. fail(2) - Fail in delt test
|
|
3. abort(3) - Delt test aborts
|
|
"
|
|
::= { hwBTSSAdslDeltTestEntry 2 }
|
|
hwBTSSAdslDeltTestResultNo OBJECT-TYPE
|
|
SYNTAX Integer32(1..255)
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Delt test result serial number.
|
|
Range: 1-255
|
|
"
|
|
::= { hwBTSSAdslDeltTestEntry 3 }
|
|
hwBTSSAdslDeltTestResultLastFlag OBJECT-TYPE
|
|
SYNTAX INTEGER{false(0), true(1)}
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Last package flag for test result.
|
|
Options:
|
|
1. false(0) - This is not the last package
|
|
2. true(1) - The last package
|
|
"
|
|
::= { hwBTSSAdslDeltTestEntry 4 }
|
|
hwBTSSAdslDeltTestResult OBJECT-TYPE
|
|
SYNTAX OCTET STRING(SIZE(0..1500))
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Delt test result data."
|
|
::= { hwBTSSAdslDeltTestEntry 5 }
|
|
|
|
-- Loop line tone Begin
|
|
hwBTSSLoopLineToneOprTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF HwBTSSLoopLineToneOprEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The table hwBTSSLoopLineToneOprTable is used to Loop Line Tone.
|
|
The index of this table is ifIndex.
|
|
"
|
|
::= { hwBTestMIBObjects 23 }
|
|
|
|
hwBTSSLoopLineToneOprEntry OBJECT-TYPE
|
|
SYNTAX HwBTSSLoopLineToneOprEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The table hwBTSSLoopLineToneOprTable is used to Loop Line Tone.
|
|
The index of this entry is ifIndex.
|
|
"
|
|
INDEX
|
|
{
|
|
ifIndex
|
|
}
|
|
::= { hwBTSSLoopLineToneOprTable 1 }
|
|
|
|
HwBTSSLoopLineToneOprEntry ::=
|
|
SEQUENCE
|
|
{
|
|
hwBTSSLoopLineToneOprType
|
|
INTEGER,
|
|
hwBTSSLoopLineToneIntensity
|
|
INTEGER,
|
|
hwBTSSLoopLineToneBusyFlag
|
|
INTEGER,
|
|
hwBTSSLoopLineToneResult
|
|
INTEGER
|
|
}
|
|
|
|
hwBTSSLoopLineToneOprType OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
check(1),
|
|
send(2),
|
|
stopsend(3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Operation type of BTSS loop line tone
|
|
Options:
|
|
1. check(1) - Indicates that checking the signal tone is started
|
|
2. send(2) - Indicates that sending the signal tone is started
|
|
3. stopsend(3) - Indicates that stopping sending the signal tone is started
|
|
"
|
|
::= { hwBTSSLoopLineToneOprEntry 1 }
|
|
|
|
hwBTSSLoopLineToneIntensity OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
fivedB(1),
|
|
tendB(2),
|
|
fifteendB(3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Tone intensity of BTSS loop line tone.
|
|
Options:
|
|
1. fivedB(1) - Tone intensity of BTSS is five dB
|
|
2. tendB(2) - Tone intensity of BTSS is ten dB
|
|
3. fifteendB(3) - Tone intensity of BTSS is fifteen dB
|
|
"
|
|
::= { hwBTSSLoopLineToneOprEntry 2 }
|
|
|
|
hwBTSSLoopLineToneBusyFlag OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
busyNoTest(1),
|
|
busyTest(2),
|
|
busystrenTest(3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Tested port force test of BTSS loop line tone.
|
|
Options:
|
|
1. busyNoTest(1) - No test on busy
|
|
2. busyTest(2) - Test on busy
|
|
3. busystrenTest(3) - Forced test on busy
|
|
"
|
|
::= { hwBTSSLoopLineToneOprEntry 3 }
|
|
|
|
hwBTSSLoopLineToneResult OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
succeed(1),
|
|
failed(2)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Operate result of BTSS loop line tone.
|
|
Options:
|
|
1. succeed(1) - The test of BTSS loop line tone is successful
|
|
2. failed(2) - Failed in BTSS loop line tone test
|
|
"
|
|
::= { hwBTSSLoopLineToneOprEntry 4 }
|
|
|
|
--loop line tone End
|
|
hwBTSSSeltAuxPortCfgTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF HwBTSSSeltAuxPortCfgEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This table sets assistance port for SELT.
|
|
The index of this table is hwBTSSSeltAuxedPortIfIndex.
|
|
"
|
|
::= { hwBTestMIBObjects 24 }
|
|
|
|
hwBTSSSeltAuxPortCfgEntry OBJECT-TYPE
|
|
SYNTAX HwBTSSSeltAuxPortCfgEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This table sets assistance port for SELT.
|
|
The index of this entry is hwBTSSSeltAuxedPortIfIndex.
|
|
"
|
|
INDEX
|
|
{
|
|
hwBTSSSeltAuxedPortIfIndex
|
|
}
|
|
::= { hwBTSSSeltAuxPortCfgTable 1 }
|
|
|
|
HwBTSSSeltAuxPortCfgEntry ::=
|
|
SEQUENCE
|
|
{
|
|
hwBTSSSeltAuxedPortIfIndex
|
|
Integer32,
|
|
hwBTSSSeltAuxPortIfIndex
|
|
Integer32,
|
|
hwBTSSSeltAuxPortRowStatus
|
|
RowStatus
|
|
}
|
|
|
|
hwBTSSSeltAuxedPortIfIndex OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ifindex of the Auxed port. If there is only one global Auxed port,
|
|
the value is 65535.
|
|
"
|
|
::= { hwBTSSSeltAuxPortCfgEntry 1 }
|
|
|
|
hwBTSSSeltAuxPortIfIndex OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Assistance port ifIndex"
|
|
::= { hwBTSSSeltAuxPortCfgEntry 2 }
|
|
|
|
hwBTSSSeltAuxPortRowStatus OBJECT-TYPE
|
|
SYNTAX RowStatus
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Row status(add(4), delete(6)) of the Aux port."
|
|
::= { hwBTSSSeltAuxPortCfgEntry 3 }
|
|
|
|
-- 1.3.6.1.4.1.2011.6.21.3.1.1.25
|
|
hwBTSSAdslSeltLevelTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF HwBTSSAdslSeltLevelEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This table supports the configuration of adsl selt level.
|
|
The indexes of this table are hwFrameIndex and hwSlotIndex.
|
|
"
|
|
::= { hwBTestMIBObjects 25 }
|
|
|
|
-- 1.3.6.1.4.1.2011.6.21.3.1.1.25.1
|
|
hwBTSSAdslSeltLevelEntry OBJECT-TYPE
|
|
SYNTAX HwBTSSAdslSeltLevelEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This table supports the configuration of adsl selt level.
|
|
The indexes of this entry are hwFrameIndex and hwSlotIndex.
|
|
"
|
|
INDEX { hwFrameIndex, hwSlotIndex }
|
|
::= { hwBTSSAdslSeltLevelTable 1 }
|
|
|
|
HwBTSSAdslSeltLevelEntry ::=
|
|
SEQUENCE
|
|
{
|
|
hwBTSSAdslSeltLevel
|
|
Integer32
|
|
}
|
|
|
|
-- 1.3.6.1.4.1.2011.6.21.3.1.1.25.1.1
|
|
hwBTSSAdslSeltLevel OBJECT-TYPE
|
|
SYNTAX Integer32 (-1 | 1..4)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The level of adsl SELT:
|
|
1 Level0;
|
|
2 Level1;
|
|
3 Level2;
|
|
4 Level3.
|
|
A special value of -1 indicates the level of adsl SELT is invalid.
|
|
"
|
|
::= { hwBTSSAdslSeltLevelEntry 1 }
|
|
|
|
-- 1.3.6.1.4.1.2011.6.21.3.1.1.26
|
|
hwBTSSAdslSeltCalibrationTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF HWBTSSAdslSeltCalibrationtEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This table describes calibration data of selt test.
|
|
The index of this table is ifIndex.
|
|
"
|
|
::= { hwBTestMIBObjects 26 }
|
|
|
|
hwBTSSAdslSeltCalibrationEntry OBJECT-TYPE
|
|
SYNTAX HWBTSSAdslSeltCalibrationtEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This table describes calibration data of selt test.
|
|
The index of this entry is ifIndex.
|
|
"
|
|
INDEX
|
|
{
|
|
ifIndex
|
|
}
|
|
::= { hwBTSSAdslSeltCalibrationTable 1 }
|
|
|
|
HWBTSSAdslSeltCalibrationtEntry ::=
|
|
SEQUENCE
|
|
{
|
|
hwBTSSAdslSeltCalibrationInvVendorId OCTET STRING,
|
|
hwBTSSAdslSeltCalibrationDataSegment1 OCTET STRING,
|
|
hwBTSSAdslSeltCalibrationDataSegment2 OCTET STRING
|
|
}
|
|
|
|
-- 1.3.6.1.4.1.2011.6.21.3.1.1.26.1.1
|
|
hwBTSSAdslSeltCalibrationInvVendorId OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(8))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"It consists of 8 binary octets, including a
|
|
provider code.
|
|
"
|
|
::= { hwBTSSAdslSeltCalibrationEntry 1 }
|
|
|
|
hwBTSSAdslSeltCalibrationDataSegment1 OBJECT-TYPE
|
|
SYNTAX OCTET STRING(SIZE(0..8192))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The part 1 of selt calibration data.
|
|
The unit of selt calibration data is 0.00001.
|
|
"
|
|
::= { hwBTSSAdslSeltCalibrationEntry 2 }
|
|
|
|
hwBTSSAdslSeltCalibrationDataSegment2 OBJECT-TYPE
|
|
SYNTAX OCTET STRING(SIZE(0..8192))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The part 2 of selt calibration data.
|
|
The unit of selt calibration data is 0.00001.
|
|
"
|
|
::= { hwBTSSAdslSeltCalibrationEntry 3 }
|
|
|
|
hwBTestTraps OBJECT IDENTIFIER ::= { hwBTest 2 }
|
|
|
|
hwBTestTrapVbOids OBJECT IDENTIFIER ::= { hwBTestTraps 1 }
|
|
|
|
hwBTestVbOidsReason OBJECT IDENTIFIER ::= { hwBTestTrapVbOids 2 }
|
|
|
|
hwBTSSCqtOfflineReason OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
commFail(1),
|
|
userReset(2)
|
|
}
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Cqt module offline reason.
|
|
Options:
|
|
1. commFail(1) - CQT module communication fail. Resolving method:Check CQT module running normal
|
|
2. userReset(2) - User reset command
|
|
"
|
|
::= { hwBTestVbOidsReason 1 }
|
|
|
|
hwBTSSRequestID OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"NMS request ID."
|
|
::= { hwBTestVbOidsReason 2 }
|
|
|
|
hwBTestAlarmTraps OBJECT IDENTIFIER ::= { hwBTestTraps 2 }
|
|
|
|
hwBTestAlarmTrapsOIDs OBJECT IDENTIFIER ::= { hwBTestAlarmTraps 0 }
|
|
|
|
hwBTSSCqtOnlineTrap NOTIFICATION-TYPE
|
|
OBJECTS { ifIndex }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"CQT unit online status trap.
|
|
This notification indicates alarm when CQT unit online.
|
|
enumFirst:
|
|
explain: CQT module communication OK
|
|
resolving method:NA.
|
|
"
|
|
::= { hwBTestAlarmTrapsOIDs 1 }
|
|
|
|
hwBTSSCqtOfflineTrap NOTIFICATION-TYPE
|
|
OBJECTS { ifIndex, hwBTSSCqtOfflineReason }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"CQT unit offline status trap.
|
|
This notification indicates alarm when CQT unit offline.
|
|
"
|
|
::= { hwBTestAlarmTrapsOIDs 2 }
|
|
|
|
hwBTestGeneralTraps OBJECT IDENTIFIER ::= { hwBTestTraps 3 }
|
|
|
|
hwBTestGeneralTrapsOIDs OBJECT IDENTIFIER ::= { hwBTestGeneralTraps 0 }
|
|
|
|
hwBTSSCoStartTrap NOTIFICATION-TYPE
|
|
OBJECTS { ifIndex, hwBTSSCoOperType, hwBTSSCoTestResult }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Start Co test trap.
|
|
This notification indicates alarm when starting Co test.
|
|
"
|
|
::= { hwBTestGeneralTrapsOIDs 1 }
|
|
|
|
hwBTSSCoStopTrap NOTIFICATION-TYPE
|
|
OBJECTS { ifIndex, hwBTSSCoOperType, hwBTSSCoTestResult }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Stop Co test trap.
|
|
This notification indicates alarm when stopping Co test.
|
|
"
|
|
::= { hwBTestGeneralTrapsOIDs 2 }
|
|
|
|
hwBTSSTestedPortOperTrap NOTIFICATION-TYPE
|
|
OBJECTS { ifIndex,hwBTSSTestedPortOperType,hwBTSSTestedPortOperMode,hwBTSSTestedPortOperResult }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Tested port operation trap.
|
|
This notification indicates alarm when tested port operation.
|
|
"
|
|
::= { hwBTestGeneralTrapsOIDs 3 }
|
|
|
|
hwBTSSCqtTransTestOperResultTrap NOTIFICATION-TYPE
|
|
OBJECTS { ifIndex,hwBTSSCqtTransTestOperType,hwBTSSCqtTransTestOperResult }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Cqt transparent test trap.
|
|
This notification indicates alarm when starting or stoping Cqt transparent test.
|
|
"
|
|
::= { hwBTestGeneralTrapsOIDs 4 }
|
|
|
|
hwBTSSCqtTransTestResultTrap NOTIFICATION-TYPE
|
|
OBJECTS { ifIndex,hwBTSSCqtTransTestResultLastFlag,hwBTSSCqtTransTestResultNo,hwBTSSCqtTransTestResult }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Cqt transparent test trap.
|
|
This notification indicates alarm when reporting the result after Cqt transparent test.
|
|
"
|
|
::= { hwBTestGeneralTrapsOIDs 5 }
|
|
|
|
hwBTSSLoopLineToneOperTrap NOTIFICATION-TYPE
|
|
OBJECTS { hwBTSSLoopLineToneResult }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"loop line tone test result trap: 1:hwBTSSLoopLineToneResult.
|
|
This notification indicates alarm when reporting the test result of Loop Line Tone.
|
|
"
|
|
::= { hwBTestGeneralTrapsOIDs 6 }
|
|
|
|
hwBTSSCaptureTrap NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
hwBTSSRequestID,
|
|
ifIndex,
|
|
hwBTSSTestedPortOperType,
|
|
hwBTSSTestedPortOperMode,
|
|
hwBTSSTestedPortOperResult
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"BTSS capture trap.
|
|
This trap is sent when BTSS capture result reported.
|
|
"
|
|
::= { hwBTestGeneralTrapsOIDs 7 }
|
|
|
|
hwBTSSDeltResultDataTrap NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
hwBTSSAdslDeltTestResultNo,
|
|
hwBTSSRequestID,
|
|
ifIndex,
|
|
hwBTSSAdslDeltTestResultLastFlag,
|
|
hwBTSSAdslDeltTestResult
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"BTSS delt result trap.
|
|
This notification indicates alarm when captures result data of BTSS delt test.
|
|
"
|
|
::= { hwBTestGeneralTrapsOIDs 8 }
|
|
|
|
END
|
|
|