Observium_CE/mibs/huawei/HUAWEI-BTEST-MIB

1864 lines
83 KiB
Plaintext

-- ============================================================================
-- Copyright (C) 2012 by HUAWEI TECHNOLOGIES. All rights reserved.
-- Description: This MIB is used for defining Huawei's BTEST MIB objects, which
-- is used for Broad test.
-- Reference:
-- Version: V3.14
-- ============================================================================
HUAWEI-BTEST-MIB DEFINITIONS ::= BEGIN
IMPORTS
huaweiUtility
FROM HUAWEI-MIB
HWPortType
FROM HUAWEI-TC-MIB
ifIndex
FROM IF-MIB
hwFrameIndex,hwSlotIndex
FROM HUAWEI-DEVICE-MIB
Integer32, Unsigned32, OBJECT-TYPE, MODULE-IDENTITY, NOTIFICATION-TYPE
FROM SNMPv2-SMI
TEXTUAL-CONVENTION, RowStatus
FROM SNMPv2-TC
hwTestGroupNo
FROM HUAWEI-COMMTEST-MIB;
hwBTest MODULE-IDENTITY
LAST-UPDATED "201201090000Z"
ORGANIZATION "Huawei Technologies Co.,Ltd."
CONTACT-INFO
"Huawei Industrial Base
Bantian, Longgang
Shenzhen 518129
People's Republic of China
Website: http://www.huawei.com
Email: support@huawei.com
"
DESCRIPTION "This MIB is used for defining Huawei's BTEST MIB objects,which
is used for Broad test.
"
-- Revision history
REVISION "201201090000Z"
DESCRIPTION "V3.14, modify the description of the leaf hwBTSSAdslSeltTestParamUnCalibLineScale, hwBTSSAdslSeltTestParamUnCalibEchoRespReal,
hwBTSSAdslSeltTestParamUnCalibEchoRespImg, hwBTSSAdslSeltTestParamCalibEchoRespReal, hwBTSSAdslSeltTestParamCalibEchoRespImg,
hwBTSSAdslSeltTestParamVarUerC, hwBTSSAdslSeltTestParamQSPsdValue, hwBTSSAdslSeltTestParamUpShnCap, hwBTSSAdslSeltTestParamAttnAt180KHZ,
hwBTSSAdslSeltTestParamAttnAt300KHZ, hwBTSSAdslSeltTestParamUerMmdC, hwBTSSAdslSeltTestParamQlnMmdC.
"
REVISION "201105040000Z"
DESCRIPTION "V3.13, add leaf node hwBTSSAdslSeltTestParamCalcEnable of hwBTSSAdslSeltTestTable for setting selt test calculation switch.
Add hwBTSSAdslSeltCalibrationTable for describing calibration data of selt test.
"
REVISION "201102220000Z"
DESCRIPTION "V3.12, changes in this revision:
modify the description of the leaf hwBTSSTestedPortOperMode,hwBTSSAdslSeltTestParamUmeC,
hwBTSSAdslSeltTestParamCalibLineScale,hwBTSSAdslSeltTestParamQmeC,
hwBTSSAdslSeltTestParamUnCalibLineScale,hwBTSSTestedPortOperMode.
"
REVISION "201102120000Z"
DESCRIPTION "V3.11, changes in this revision:
Add value resumeport(5) for hwBTSSTestedPortOperType.
"
REVISION "201010290000Z"
DESCRIPTION "V3.10, changes in this revision:
Add value -1(invalid) for hwBTSSAdslSeltLevel and modify the description.
"
REVISION "201009290000Z"
DESCRIPTION "V3.09, changes in this revision:
Add leaf node for new standard, include:
hwBTSSAdslSeltTestParamVarUerC
hwBTSSAdslSeltTestParamUerMmdC
hwBTSSAdslSeltTestParamQlnMmdC
hwBTSSAdslSeltTestParamUmeC
hwBTSSAdslSeltTestParamQmeC
hwBTSSAdslSeltTestParamUerStatus
hwBTSSAdslSeltTestParamQlnStatus
Modify the range of leaf node, include:
hwBTSSAdslSeltTestParamUnCalibLineScale
hwBTSSAdslSeltTestParamUnCalibEchoRespReal
hwBTSSAdslSeltTestParamUnCalibEchoRespImg
hwBTSSAdslSeltTestParamCalibLineScale
hwBTSSAdslSeltTestParamCalibEchoRespReal
hwBTSSAdslSeltTestParamCalibEchoRespImg
hwBTSSAdslSeltTestParamQSPsdValue
"
REVISION "201009270900Z"
DESCRIPTION "V3.08, changes in this revision:
modify the description of the hwBTSSCaptureTrap.
"
REVISION "201007120900Z"
DESCRIPTION "V3.07, changes in this revision:
Add value -1(invalid) for hwBTSSTestedPortOperType and six enumerate values for hwBTSSTestedPortOperMode
to support get operation.
"
REVISION "201006220900Z"
DESCRIPTION "V3.06, changes in this revision:
Modify chinese character.
"
REVISION "201003220000Z"
DESCRIPTION "V3.05, changes in this revision:
Add leaf node hwBTSSAdslSeltTestOperType of hwBTSSAdslSeltTestTable for setting or obtaining selt test
operation type.
Add leaf node hwBTSSAdslSeltTestParamLoopTermin of hwBTSSAdslSeltTestTable for obtaining selt test
parameter Loop Termination.
Add leaf node hwBTSSAdslSeltTestParamLoopGauge of hwBTSSAdslSeltTestTable for setting or obtaining selt
test parameter Loop Gauge.
Add leaf node hwBTSSAdslDeltTestOperType of hwBTSSAdslDeltTestTable for setting or obtaining delt test
operation type.
Modify MAX-ACCESS ,include:
hwBTSSAdslSeltTestParamAttnAt180KHZ
hwBTSSAdslSeltTestParamAttnAt300KHZ
hwBTSSAdslSeltTestParamQSPsdValue
"
REVISION "201002080000Z"
DESCRIPTION "V3.04, changes in this revision:
Delete the definition of the trap node,include:
hwBTSSCaptureTrap
hwBTSSSeltStartReplyTrap
hwBTSSSeltTestResultFirstFrameTrap
hwBTSSSeltTestResultSecondFrameTrap
hwBTSSSeltTestResultThirdFrameTrap
hwBTSSSeltTestResultFourFrameTrap
hwBTSSSeltTestResultFifthsFrameTrap
hwBTSSSeltTestResultSixthFrameTrap
hwBTSSSeltTestResultSeventhFrameTrap
"
REVISION "201001120000Z"
DESCRIPTION "V3.03, changes in this revision:
Add the definition of hwBTSSDeltResultDataTrap node.
"
REVISION "200906040900Z"
DESCRIPTION "V3.02, changes in this revision:
Add the definition of SYNTAX HWBTSSxDslLineOverLap, and change the SYNTAX from INTEGER to HWBTSSxDslLineOverLap
for hwBTSSxDslLineOverlapType of table hwBTSSxDslLineCfgTable
Add leaf hwBTSSCoTestBusyFlag into table hwBTSSCoTestTable OBJECT-TYPE
Add hwBTSSAuxPortCfgTable for describing aux port used for BTSS.
Add hwBTSSTestedPortOperTable for describing operation for tested port.
Add hwBTSSCqtTransTestTable for describeing CQT test by transparent command.
Add hwBTSSMultiFrameMiscOperTable for describing test relatived operation for multi-frame.
Add hwBTSSAdslSeltTestTable for describing selt test for adsl2+.
Add hwBTSSAdslDeltTestTable for describing Delt test for adsl2+.
Add hwBTSSLoopLineToneOprTable for Loop Line Tone.
Add leaf node hwBTSSTestedPortOperTrap for sending trap when tested port operation.
Add leaf node hwBTSSCqtTransTestOperResultTrap for sending trap when starting or stoping Cqt transparent test.
Add leaf node hwBTSSCqtTransTestResultTrap for sending trap when reporting the result after Cqt transparent test.
Add leaf node hwBTSSLoopLineToneOperTrap for sending trap when reporting the test result of Loop Line Tone.
Delete leafs hwBTSSxDslLineExtCrossMatrixRauModuleNo and wBTSSxDslLineExtCrossMatrixRauPortNo from table
Delete tables, include:
hwBTSSxDslLineCfgTable
hwBTSSCqtTemplateTable
hwBTSSCqtMaintainTable
hwBTSSCqtFrTestTable
hwBTSSCqtTdrTestTable
hwBTSSCqtDmtTestTable
hwBTSSCqtNseTestTable
hwBTSSCqtLbTestTable
hwBTSSCqtLcTestTable
hwBTSSCqtFrTestResultTable
hwBTSSCqtTdrTestResultTable
hwBTSSCqtDmtTestResultTable
hwBTSSCqtNseTestResultTable
hwBTSSCqtLbTestResultTable
hwBTSSCqtLcTestResultTable
Delete traps, include:
hwBTSSCqtFrTestTrap
hwBTSSCqtTdrTestTrap
hwBTSSCqtDmtTestTrap
hwBTSSCqtNseTestTrap
hwBTSSCqtLbTestTrap
hwBTSSCqtLcTestTrap
hwBTSSCqtStopFrTestTrap
hwBTSSCqtStopTdrTestTrap
hwBTSSCqtStopDmtTestTrap
hwBTSSCqtStopNseTestTrap
hwBTSSCqtStopLbTestTrap
hwBTSSCqtStopLcTestTrap
"
REVISION "200308280900Z"
DESCRIPTION "V3.00, change in this revision:
Change the style of description.
"
REVISION "200306280900Z"
DESCRIPTION "V2.00, change in this revision:
Correct the SYNTAX.
"
REVISION "200304280900Z"
DESCRIPTION "V1.00, initial version, by FixNet Mib Group."
::= { hwTest 3 }
HWBTSSxDslLineOverLap ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"Set overlap mode of xDSL with PSTN line.
Options:
1. overLap(1) - xDSL overlap with POTS line
2. direct(2) - There is no pots line, no splitter, no phone
3. unknown(3) - The mode is unknown
"
SYNTAX INTEGER
{
overLap(1),
direct(2),
unknown(3)
}
CqtQualitativeResultString ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"This string to contain qualitative result."
SYNTAX OCTET STRING (SIZE (0..255))
hwTest OBJECT IDENTIFIER ::= { huaweiUtility 21 }
hwBTestMib OBJECT IDENTIFIER ::= { hwBTest 1 }
hwBTestMIBObjects OBJECT IDENTIFIER ::= { hwBTestMib 1 }
hwBTSSxDslLineCfgTable OBJECT-TYPE
SYNTAX SEQUENCE OF HwBTSSxDslLineCfgEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The hwBTSSxDslLineCfgTable table describes xDSL line configuration.
This table is used for bandwidth test.
The index of this table is ifIndex.
"
::= { hwBTestMIBObjects 1 }
hwBTSSxDslLineCfgEntry OBJECT-TYPE
SYNTAX HwBTSSxDslLineCfgEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The hwBTSSxDslLineCfgTable table describes xDSL line configuration.
This table is used for bandwidth test.
The index of this entry is ifIndex.
"
INDEX { ifIndex }
::= { hwBTSSxDslLineCfgTable 1 }
HwBTSSxDslLineCfgEntry ::=
SEQUENCE
{
hwBTSSxDslLineOverlapType HWBTSSxDslLineOverLap
}
hwBTSSxDslLineOverlapType OBJECT-TYPE
SYNTAX HWBTSSxDslLineOverLap
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Overlap mode of xDSL with PSTN line.
Options:
1. overLap(1) - xDSL overlap with POTS line
2. direct(2) - There is no pots line, no splitter, no phone
3. unknown(3) - The mode is unknown
Default: unknown(3)
"
DEFVAL { 3 }
::= { hwBTSSxDslLineCfgEntry 1 }
hwBTSSCoTestTable OBJECT-TYPE
SYNTAX SEQUENCE OF HwBTSSCoTestEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"xDSL central office emulational measurement table.The table is used for xDSL central emulational measurement.
The index of this table is ifIndex.
"
::= { hwBTestMIBObjects 2 }
hwBTSSCoTestEntry OBJECT-TYPE
SYNTAX HwBTSSCoTestEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"xDSL central office emulational measurement table.The table is used for xDSL central emulational measurement.
The index of this entry is ifIndex.
"
INDEX { ifIndex }
::= { hwBTSSCoTestTable 1 }
HwBTSSCoTestEntry ::=
SEQUENCE
{
hwBTSSCoOperType
INTEGER,
hwBTSSCoTestResult
INTEGER,
hwBTSSCoTestBusyFlag
INTEGER
}
hwBTSSCoOperType OBJECT-TYPE
SYNTAX INTEGER
{
stop(1),
start(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"CO emulational operation type.
Options:
1. stop(1) - Stop CO emulational
2. start(2) - Start CO emulational
"
::= { hwBTSSCoTestEntry 1 }
hwBTSSCoTestResult OBJECT-TYPE
SYNTAX INTEGER
{
normal(1),
testfail(2)
}
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"CO emulational test result.
Options:
1. normal(1) - The test of CO emulational is successful
2. testfail(2) - Fail in test of CO emulational
"
::= { hwBTSSCoTestEntry 2 }
hwBTSSCoTestBusyFlag OBJECT-TYPE
SYNTAX INTEGER
{
busyNoTest(1),
busyTest(2),
busystrenTest(3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"CO force test flag
Options:
1. busyNoTest(1) - No test on busy
2. busyTest(2) - Test on busy
3. busystrenTest(3) - Forced test on busy
"
::= { hwBTSSCoTestEntry 3 }
hwBTSSAuxPortCfgTable OBJECT-TYPE
SYNTAX SEQUENCE OF HwBTSSAuxPortCfgEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Configuration table of the broadband test auxiliary port
This table is used to configure a certain type of emulation port required in the CO emulation test.
The indexes of this table are hwTestGroupNo and hwBTSSAuxPortType.
"
::= { hwBTestMIBObjects 17 }
hwBTSSAuxPortCfgEntry OBJECT-TYPE
SYNTAX HwBTSSAuxPortCfgEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Configuration table of the broadband test auxiliary port
This table is used to configure a certain type of emulation port required in the CO emulation test.
The indexes of this entry are hwTestGroupNo and hwBTSSAuxPortType.
"
INDEX { hwTestGroupNo, hwBTSSAuxPortType }
::= { hwBTSSAuxPortCfgTable 1 }
HwBTSSAuxPortCfgEntry ::=
SEQUENCE
{
hwBTSSAuxPortType INTEGER,
hwBTSSAuxPortIfIndex Integer32,
hwBTSSAuxPortRowStatus RowStatus
}
hwBTSSAuxPortType OBJECT-TYPE
SYNTAX INTEGER
{
adsl(1),
vdsl(2),
gshdsl(3)
}
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Assistance port type of BTSS.
Options:
1. adsl(1) - Assistance port type of BTSS is adsl
2. vdsl(2) - Assistance port type of BTSS is vdsl
3. gshdsl(3) - Assistance port type of BTSS is gshdsl
"
::= { hwBTSSAuxPortCfgEntry 1 }
hwBTSSAuxPortIfIndex OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Assistance port ifIndex of BTSS."
::= { hwBTSSAuxPortCfgEntry 2 }
hwBTSSAuxPortRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Row status(add(4),delete(6))."
::= { hwBTSSAuxPortCfgEntry 3 }
hwBTSSTestedPortOperTable OBJECT-TYPE
SYNTAX SEQUENCE OF HwBTSSTestedPortOperEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table describes operation for tested port.
The index of this table is ifIndex.
"
::= { hwBTestMIBObjects 18 }
hwBTSSTestedPortOperEntry OBJECT-TYPE
SYNTAX HwBTSSTestedPortOperEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table describes operation for tested port.
The index of this entry is ifIndex.
"
INDEX
{
ifIndex
}
::= { hwBTSSTestedPortOperTable 1 }
HwBTSSTestedPortOperEntry ::=
SEQUENCE
{
hwBTSSTestedPortOperType INTEGER,
hwBTSSTestedPortOperMode INTEGER,
hwBTSSTestedPortOperResult INTEGER,
hwBTSSTestedPortTestBusyFlag INTEGER,
hwBTSSTestedPortTestPOTSFlag INTEGER
}
hwBTSSTestedPortOperType OBJECT-TYPE
SYNTAX INTEGER
{
capture(1),
release(2),
startmonitor(3),
stopmonitor(4),
resumeport(5),
invalid(-1)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Operation type of BTSS tested port.
Options:
1. capture(1) - Capture
2. release(2) - Release
3. startmonitor(3) - Start monitor
4. stopmonitor(4) - Stop monitor
5. resumeport(5) - Resume port
6. invalid(-1) - Invalid value
"
::= { hwBTSSTestedPortOperEntry 1 }
hwBTSSTestedPortOperMode OBJECT-TYPE
SYNTAX INTEGER
{
inline(1),
outline(2),
monitor(3),
both(4),
meltNoCutxDSL(5),
meltForceCutxDSL(6),
testLineLoopback(7),
internalResistorLoopback(8),
passthroughmode(9)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Operation mode of BTSS tested port.
Options:
1. inline(1) - BTSS tested port in test
2. outline(2) - BTSS tested port out test
3. monitor(3) - Monitoring BTSS tested port
4. both(4) - Capture for circuit and loop-line test
5. meltNoCutxDSL(5) - Capture for melt chip test with co and cpe connecting
6. meltForceCutxDSL(6) - Capture for melt chip test with co and cpe disconnecting
7. testLineLoopback(7) - Capture for test line loopback
8. internalResistorLoopback(8) - Capture for internal resistor loopback
9. passthroughmode(9) - No capture
Default: passthroughmode(9)
"
::= { hwBTSSTestedPortOperEntry 2 }
hwBTSSTestedPortOperResult OBJECT-TYPE
SYNTAX INTEGER
{
normal(1),
fail(2),
timeout(4)
}
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"Test result of BTSS tested port.
Options:
1. normal(1) - The test of BTSS tested port is successful
2. fail(2) - Fail in test of BTSS tested port
3. timeout(4) - The test of BTSS tested port is timeout
"
::= { hwBTSSTestedPortOperEntry 3 }
hwBTSSTestedPortTestBusyFlag OBJECT-TYPE
SYNTAX INTEGER
{
busyNoTest(1),
busyTest(2),
busystrenTest(3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Tested port force test.
Options:
1. busyNoTest(1) - No test on busy
2. busyTest(2) - Test on busy
3. busystrenTest(3) - Forced test on busy
"
::= { hwBTSSTestedPortOperEntry 4 }
hwBTSSTestedPortTestPOTSFlag OBJECT-TYPE
SYNTAX INTEGER
{
noCutPOTS(1),
busyNoTest(2),
busyTest(3),
busystrenTest(4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Tested port POTS service flag
Options:
1. noCutPOTS(1) - No cut off POTS
2. busyNoTest(2) - No test on POTS busy (Cut off POTS)
3. busyTest(3) - Test on POTS busy (Cut off POTS)
4. busystrenTest(4) - Forced test on POTS busy (Cut off POTS)
"
::= { hwBTSSTestedPortOperEntry 5 }
hwBTSSCqtTransTestTable OBJECT-TYPE
SYNTAX SEQUENCE OF HwBTSSCqtTransTestEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table describes CQT test by transparent command.
The index of this table is ifIndex.
"
::= { hwBTestMIBObjects 19 }
hwBTSSCqtTransTestEntry OBJECT-TYPE
SYNTAX HwBTSSCqtTransTestEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table describes CQT test by transparent command.
The index of this entry is ifIndex.
"
INDEX { ifIndex }
::= { hwBTSSCqtTransTestTable 1 }
HwBTSSCqtTransTestEntry ::=
SEQUENCE
{
hwBTSSCqtTransTestOperType INTEGER,
hwBTSSCqtTransTestCRCMode INTEGER,
hwBTSSCqtTransTestOperResult INTEGER,
hwBTSSCqtTransTestTxCmd OCTET STRING,
hwBTSSCqtTransTestResultNo Integer32,
hwBTSSCqtTransTestResultLastFlag INTEGER,
hwBTSSCqtTransTestResult OCTET STRING
}
hwBTSSCqtTransTestOperType OBJECT-TYPE
SYNTAX INTEGER
{
stop(1),
start(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"CQT transparent Operation type
Options:
1. stop(1) - Stop CQT transparent test
2. start(2) - Start CQT transparent test
"
::= { hwBTSSCqtTransTestEntry 1 }
hwBTSSCqtTransTestCRCMode OBJECT-TYPE
SYNTAX INTEGER
{
disable(1),
enable(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"CRC Operation type of CQT transparent.
Options:
1. disable(1) - Disable CQT transparent
2. enable(2) - Enable CQT transparent
Default: disable(1)
"
DEFVAL { 1 }
::= { hwBTSSCqtTransTestEntry 2 }
hwBTSSCqtTransTestOperResult OBJECT-TYPE
SYNTAX INTEGER
{
normal(1),
fail(2),
abort(3),
powerfeed(4)
}
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"CQT transparent Operation result.
Options:
1. normal(1) - The CQT transparent test is successful
2. fail(2) - The CQT transparent test fails
3. abort(3) - The CQT transparent test aborts
4. powerfeed(4) - The CQT transparent test power feeds
"
::= { hwBTSSCqtTransTestEntry 3 }
hwBTSSCqtTransTestTxCmd OBJECT-TYPE
SYNTAX OCTET STRING(SIZE(0..251))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Sending command string in TL1 format."
::= { hwBTSSCqtTransTestEntry 4 }
hwBTSSCqtTransTestResultNo OBJECT-TYPE
SYNTAX Integer32(1..255)
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"Test result No.
Range: 1-255
"
::= { hwBTSSCqtTransTestEntry 5 }
hwBTSSCqtTransTestResultLastFlag OBJECT-TYPE
SYNTAX INTEGER{false(0), true(1)}
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"Last package flag for test result.
Options:
1. false(0) - This is not the last package
2. true(1) - The last package
"
::= { hwBTSSCqtTransTestEntry 6 }
hwBTSSCqtTransTestResult OBJECT-TYPE
SYNTAX OCTET STRING(SIZE(0..231))
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"CQT transparent Test result."
::= { hwBTSSCqtTransTestEntry 7 }
hwBTSSMultiFrameMiscOperTable OBJECT-TYPE
SYNTAX SEQUENCE OF HwBTSSMultiFrameMiscOperEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table describes test relatived operation for multi-frame.
The index of this table is ifIndex.
"
::= { hwBTestMIBObjects 20 }
hwBTSSMultiFrameMiscOperEntry OBJECT-TYPE
SYNTAX HwBTSSMultiFrameMiscOperEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table describes test relatived operation for multi-frame.
The index of this entry is ifIndex.
"
INDEX
{
ifIndex
}
::= { hwBTSSMultiFrameMiscOperTable 1 }
HwBTSSMultiFrameMiscOperEntry ::=
SEQUENCE
{
hwBTSSMultiFrameMiscCleanTest INTEGER,
hwBTSSMultiFrameMiscTestedFrame Integer32,
hwBTSSMultiFrameMiscTestedPortType HWPortType,
hwBTSSMultiFrameMiscTestedLineType HWBTSSxDslLineOverLap
}
hwBTSSMultiFrameMiscCleanTest OBJECT-TYPE
SYNTAX INTEGER{start(1)}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Clean current test on specified frame.
Options:
1. start(1) - Start clean current test
"
::= { hwBTSSMultiFrameMiscOperEntry 1 }
hwBTSSMultiFrameMiscTestedFrame OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Tested frame of BTSS multi-frame.
Default: 0
"
DEFVAL { 0 }
::= { hwBTSSMultiFrameMiscOperEntry 2 }
hwBTSSMultiFrameMiscTestedPortType OBJECT-TYPE
SYNTAX HWPortType
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Tested port type of BTSS multi-frame."
::= { hwBTSSMultiFrameMiscOperEntry 3 }
hwBTSSMultiFrameMiscTestedLineType OBJECT-TYPE
SYNTAX HWBTSSxDslLineOverLap
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Tested line type of BTSS multi-frame."
::= { hwBTSSMultiFrameMiscOperEntry 4 }
hwBTSSAdslSeltTestTable OBJECT-TYPE
SYNTAX SEQUENCE OF HWBTSSAdslSeltTestEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table describes selt test for adsl2+.
The index of this table is ifIndex.
"
::= { hwBTestMIBObjects 21 }
hwBTSSAdslSeltTestEntry OBJECT-TYPE
SYNTAX HWBTSSAdslSeltTestEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table describes selt test for adsl2+.
The index of this entry is ifIndex.
"
INDEX
{
ifIndex
}
::= { hwBTSSAdslSeltTestTable 1 }
HWBTSSAdslSeltTestEntry ::=
SEQUENCE
{
hwBTSSAdslSeltTestOperType INTEGER ,
hwBTSSAdslSeltTestOperResult INTEGER ,
hwBTSSAdslSeltTestResultNo Integer32 ,
hwBTSSAdslSeltTestResultLastFlag INTEGER ,
hwBTSSAdslSeltTestResult OCTET STRING ,
hwBTSSAdslSeltTestParamLoopLength Integer32 ,
hwBTSSAdslSeltTestParamLoopTermin INTEGER ,
hwBTSSAdslSeltTestParamLoopGauge INTEGER ,
hwBTSSAdslSeltTestParamUpShnCap Integer32 ,
hwBTSSAdslSeltTestParamDwnShnCap Integer32 ,
hwBTSSAdslSeltTestParamInbandNoise OCTET STRING ,
hwBTSSAdslSeltTestParamTerminResp OCTET STRING ,
hwBTSSAdslSeltTestParamUpMgnAtRate OCTET STRING ,
hwBTSSAdslSeltTestParamDwnMgnAtRate OCTET STRING ,
hwBTSSAdslSeltTestParamUpRateAtMgn OCTET STRING ,
hwBTSSAdslSeltTestParamDwnRateAtMgn OCTET STRING ,
hwBTSSAdslSeltTestParamLoopAttenAtFreq OCTET STRING,
hwBTSSAdslSeltTestParamUnCalibLineScale Unsigned32,
hwBTSSAdslSeltTestParamUnCalibEchoRespReal OCTET STRING,
hwBTSSAdslSeltTestParamUnCalibEchoRespImg OCTET STRING,
hwBTSSAdslSeltTestParamCalibLineScale Unsigned32,
hwBTSSAdslSeltTestParamCalibEchoRespReal OCTET STRING,
hwBTSSAdslSeltTestParamCalibEchoRespImg OCTET STRING,
hwBTSSAdslSeltTestParamVarUerC OCTET STRING,
hwBTSSAdslSeltTestParamUerMmdC Unsigned32,
hwBTSSAdslSeltTestParamQlnMmdC Unsigned32,
hwBTSSAdslSeltTestParamUmeC INTEGER,
hwBTSSAdslSeltTestParamQmeC INTEGER,
hwBTSSAdslSeltTestParamUerStatus INTEGER,
hwBTSSAdslSeltTestParamQlnStatus INTEGER,
hwBTSSAdslSeltTestParamCalcEnable INTEGER,
hwBTSSAdslSeltTestParamAttnAt180KHZ Integer32,
hwBTSSAdslSeltTestParamAttnAt300KHZ Integer32,
hwBTSSAdslSeltTestParamQSPsdValue OCTET STRING
}
hwBTSSAdslSeltTestOperType OBJECT-TYPE
SYNTAX INTEGER
{
stop(1),
start(2),
invalid(-1)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Selt test operation type.
Options:
1. stop(1) - Stop selt test of BTSS
2. start(2) - Start selt test of BTSS
3. invalid(-1) - No operation
"
::= { hwBTSSAdslSeltTestEntry 1 }
hwBTSSAdslSeltTestOperResult OBJECT-TYPE
SYNTAX INTEGER
{
normal(1),
fail(2),
abort(3)
}
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"Selt test operation result.
Options:
1. normal(1) - Selt test of BTSS is successful
2. fail(2) - Fail in selt test of BTSS
3. abort(3) - Selt test of BTSS aborts
"
::= { hwBTSSAdslSeltTestEntry 2 }
hwBTSSAdslSeltTestResultNo OBJECT-TYPE
SYNTAX Integer32(1..255)
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"Selt test result serial number.
Range: 1-255
"
::= { hwBTSSAdslSeltTestEntry 3 }
hwBTSSAdslSeltTestResultLastFlag OBJECT-TYPE
SYNTAX INTEGER{false(0), true(1)}
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"Last package flag of test.
Options:
1. false(0) - This is not the last package
2. true(1) - The last package
"
::= { hwBTSSAdslSeltTestEntry 4 }
hwBTSSAdslSeltTestResult OBJECT-TYPE
SYNTAX OCTET STRING(SIZE(0..1500))
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"Selt test result data."
::= { hwBTSSAdslSeltTestEntry 5 }
hwBTSSAdslSeltTestParamLoopLength OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Selt test parameter Loop Length.
The invalid value is -1. If no SELT is performed, no SELT data is
generated because the SELT is incomplete, or no SELT data can be
obtained from the port because the SELT data is aged and cleared,
the invalid value will be returned."
::= { hwBTSSAdslSeltTestEntry 6 }
hwBTSSAdslSeltTestParamLoopTermin OBJECT-TYPE
SYNTAX INTEGER
{
open(0),
short(1),
unknow(2),
terminated(3),
invalid(-1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Selt test parameter Loop Termination state.
Options:
1. open(0) - Indicates that the line terminal is started
2. short(1) - Indicates that the line terminal is short-circuited
3. unknow(2) - Indicates the unknown state
4. terminated(3) - Indicates that the line terminal is stopped
5. invalid(-1) - Indicates the invalid state
"
::= { hwBTSSAdslSeltTestEntry 7 }
hwBTSSAdslSeltTestParamLoopGauge OBJECT-TYPE
SYNTAX INTEGER
{
greater26awg(1),
equal26awg(2),
equal24awg(3),
less24awg(4),
unknowawg(5),
invalid(-1)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Selt test parameter Loop Gauge.
Options:
1. greater26awg(1) - Indicates that the line gauge is greater than 26
2. equal26awg(2) - Indicates that the line gauge is 26
3. equal24awg(3) - Indicates that the line gauge is 24
4. less24awg(4) - Indicates that the line gauge is smaller than 24
5. unknowawg(5) - Indicates an unknown line gauge.
6. invalid(-1) - Indicates an invalid value.
"
::= { hwBTSSAdslSeltTestEntry 8 }
hwBTSSAdslSeltTestParamUpShnCap OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Selt test parameter Upstream Shannon Capacity.
The invalid value is -1. If no SELT is performed, no SELT data is
generated because the SELT is incomplete, or no SELT data can be
obtained from the port because the SELT data is aged and cleared,
the invalid value will be returned."
::= { hwBTSSAdslSeltTestEntry 9 }
hwBTSSAdslSeltTestParamDwnShnCap OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Selt test parameter Downstream Shannon Capacity."
::= { hwBTSSAdslSeltTestEntry 10 }
hwBTSSAdslSeltTestParamInbandNoise OBJECT-TYPE
SYNTAX OCTET STRING(SIZE(0..1500))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Selt test parameter Inband Noise
512 values that indicate inband noise in dBm/Hz,
covering ADSL, ADSL2, and ADSL2+ bands, from 0 to 2.2 MHz.
"
::= { hwBTSSAdslSeltTestEntry 11 }
hwBTSSAdslSeltTestParamTerminResp OBJECT-TYPE
SYNTAX OCTET STRING(SIZE(0..1500))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Selt test parameter Termination Response
180 values that indicate termination response magnitude from 0 to 18 kft.
"
::= { hwBTSSAdslSeltTestEntry 12 }
hwBTSSAdslSeltTestParamUpMgnAtRate OBJECT-TYPE
SYNTAX OCTET STRING(SIZE(0..1500))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Selt test parameter Upstream Ratevs. Margin.
This value is a measure of the quality of your upstream data
signal relative to the noise on the line. Hundreds of values that
indicate SNR margin in DB/Hz at a particular bit rate are provided,
at a certain increments, up to 30 Mbps. This information may be plotted
with the bit rate on the X-axis and the SNR margin on the Y-axis.
"
::= { hwBTSSAdslSeltTestEntry 13 }
hwBTSSAdslSeltTestParamDwnMgnAtRate OBJECT-TYPE
SYNTAX OCTET STRING(SIZE(0..1500))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Selt test parameter Downstream Rate vs. Margin.
This value is a measure of the quality of your downstream data
signal relative to the noise on the line. Hundreds of values that
indicate SNR margin in DB/Hz at a particular bit rate are provided,
at a certain increments, up to 30 Mbps. This information may be plotted
with the bit rate on the X-axis and the SNR margin on the Y-axis.
"
::= { hwBTSSAdslSeltTestEntry 14 }
hwBTSSAdslSeltTestParamUpRateAtMgn OBJECT-TYPE
SYNTAX OCTET STRING(SIZE(0..1500))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Selt test parameter Upstream Margin vs. Rate."
::= { hwBTSSAdslSeltTestEntry 15 }
hwBTSSAdslSeltTestParamDwnRateAtMgn OBJECT-TYPE
SYNTAX OCTET STRING(SIZE(0..1500))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Selt test parameter Downstream Margin vs. Rate."
::= { hwBTSSAdslSeltTestEntry 16 }
hwBTSSAdslSeltTestParamLoopAttenAtFreq OBJECT-TYPE
SYNTAX OCTET STRING(SIZE(0..2048))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Selt test parameter loop attenuation versus frequency.
Every four bytes constitute the result of a tone.
This information may be plotted with the bit frequency
on the X-axis and the loop attenuation on the Y-axis.
"
::= { hwBTSSAdslSeltTestEntry 17 }
hwBTSSAdslSeltTestParamUnCalibLineScale OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The uncalibrated echo response, UER(i* UER_G*Df), shall be represented in linear format by a
scale factor and a normalized complex number a(i)+j*b(i), where i is a frequency index i ranging
from 0 to NSC-1, the subcarrier spacing, Df = 4.3125 kHz, and (NSC-1) * UER_G * Df is the
highest frequency supported by the SELT-PMD functionality. The UER granularity parameter,
UER_G, has two valid values: 1 and 2, indicating whether the measurements were performed using
a tone spacing of 4.3125 kHz or of 8.625 kHz. If the uncalibrated echo response is being reported
over a frequency range of 17.664 MHz or lower, UER_G shall be set to 1. If the uncalibrated echo
response is being reported over a frequency range that is greater than 17.664 MHz, UER_G shall be
set to 2.
The scale factor shall be coded as a 32-bit unsigned integer. Both a(i) and b(i) shall be coded as
32-bit 2's complement signed integers. The value of UER(i* UER_G*Df) shall be defined as:
UER(i* UER_G*Df) = (scale/2^31)*(a(i)+j*b(i))/2^31. In order to maximize precision, the scale factor
shall be chosen such that max(|a(i)|, |b(i)|) over all i is equal to 2^31-1.
NOTE - This data format supports an UER(f) granularity of 2^-31 and an UER(f) dynamic range of
approximately +6 dB to -186 dB, however it does not imply any future accuracy requirements.
An UER(i*UER_G* Df) value indicated as a(i) = b(i) = -2^31 is a special value. It indicates that no
measurement could be done for this subcarrier either because it is not supported by the SELT-PMD
function, or that the value is out of range to be represented.
"
::= { hwBTSSAdslSeltTestEntry 18 }
hwBTSSAdslSeltTestParamUnCalibEchoRespReal OBJECT-TYPE
SYNTAX OCTET STRING(SIZE(0..2048))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The uncalibrated echo response, UER(i* UER_G*Df), shall be represented in linear format by a
scale factor and a normalized complex number a(i)+j*b(i), where i is a frequency index i ranging
from 0 to NSC-1, the subcarrier spacing, Df = 4.3125 kHz, and (NSC-1) * UER_G * Df is the
highest frequency supported by the SELT-PMD functionality. The UER granularity parameter,
UER_G, has two valid values: 1 and 2, indicating whether the measurements were performed using
a tone spacing of 4.3125 kHz or of 8.625 kHz. If the uncalibrated echo response is being reported
over a frequency range of 17.664 MHz or lower, UER_G shall be set to 1. If the uncalibrated echo
response is being reported over a frequency range that is greater than 17.664 MHz, UER_G shall be
set to 2.
The scale factor shall be coded as a 32-bit unsigned integer. Both a(i) and b(i) shall be coded as
32-bit 2's complement signed integers. The value of UER(i* UER_G*Df) shall be defined as:
UER(i* UER_G*Df) = (scale/2^31)*(a(i)+j*b(i))/2^31. In order to maximize precision, the scale factor
shall be chosen such that max(|a(i)|, |b(i)|) over all i is equal to 2^31-1.
NOTE - This data format supports an UER(f) granularity of 2^-31 and an UER(f) dynamic range of
approximately +6 dB to -186 dB, however it does not imply any future accuracy requirements.
An UER(i*UER_G* Df) value indicated as a(i) = b(i) = -2^31 is a special value. It indicates that no
measurement could be done for this subcarrier either because it is not supported by the SELT-PMD
function, or that the value is out of range to be represented.
"
::= { hwBTSSAdslSeltTestEntry 19 }
hwBTSSAdslSeltTestParamUnCalibEchoRespImg OBJECT-TYPE
SYNTAX OCTET STRING(SIZE(0..2048))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The uncalibrated echo response, UER(i* UER_G*Df), shall be represented in linear format by a
scale factor and a normalized complex number a(i)+j*b(i), where i is a frequency index i ranging
from 0 to NSC-1, the subcarrier spacing, Df = 4.3125 kHz, and (NSC-1) * UER_G * Df is the
highest frequency supported by the SELT-PMD functionality. The UER granularity parameter,
UER_G, has two valid values: 1 and 2, indicating whether the measurements were performed using
a tone spacing of 4.3125 kHz or of 8.625 kHz. If the uncalibrated echo response is being reported
over a frequency range of 17.664 MHz or lower, UER_G shall be set to 1. If the uncalibrated echo
response is being reported over a frequency range that is greater than 17.664 MHz, UER_G shall be
set to 2.
The scale factor shall be coded as a 32-bit unsigned integer. Both a(i) and b(i) shall be coded as
32-bit 2's complement signed integers. The value of UER(i* UER_G*Df) shall be defined as:
UER(i* UER_G*Df) = (scale/2^31)*(a(i)+j*b(i))/2^31. In order to maximize precision, the scale factor
shall be chosen such that max(|a(i)|, |b(i)|) over all i is equal to 2^31-1.
NOTE - This data format supports an UER(f) granularity of 2^-31 and an UER(f) dynamic range of
approximately +6 dB to -186 dB, however it does not imply any future accuracy requirements.
An UER(i*UER_G* Df) value indicated as a(i) = b(i) = -2^31 is a special value. It indicates that no
measurement could be done for this subcarrier either because it is not supported by the SELT-PMD
function, or that the value is out of range to be represented.
"
::= { hwBTSSAdslSeltTestEntry 20 }
hwBTSSAdslSeltTestParamCalibLineScale OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The scale factor of calibrated echo response shall be coded as a 16 bit
unsigned integer.
"
::= { hwBTSSAdslSeltTestEntry 21 }
hwBTSSAdslSeltTestParamCalibEchoRespReal OBJECT-TYPE
SYNTAX OCTET STRING(SIZE(0..2048))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The calibrated echo response UER(i* f), shall be represented
in linear format by a scale factor and a normalized complex number a(i)+j*b(i),
where i is the subcarrier index i ranging from 0 to NSC-1 and Df = 4.3125kHz
and (NSC-1) * Df is the highest frequency supported by the SELT-PMD functionality.
The scale factor shall be coded as a 16 bit unsigned integer.
Both a(i) and b(i) shall be coded as a 16 bit 2's complement signed integer.
The value of UER(i* f) shall be defined as UER(i* f) = (scale/215)*(a(i)+j*b(i))/215.
In order to maximize precision, the scale factor shall be chosen such that max(|a(i)|, |b(i)|)
over all i is equal to 215-1. This data format supports an UER(f) granularity of 2-15
and an UER(f) dynamic range of approximately +6 dB to -90 dB.
An UER(i*Df) value indicated as a(i) = b(i) = -215 is a special value.
It indicates that no measurement could be done for this subcarrier because
it is out of the PSD mask passband or that the value is out of range to be represented.
"
::= { hwBTSSAdslSeltTestEntry 22 }
hwBTSSAdslSeltTestParamCalibEchoRespImg OBJECT-TYPE
SYNTAX OCTET STRING(SIZE(0..2048))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The calibrated echo response UER(i* f), shall be represented
in linear format by a scale factor and a normalized complex number a(i)+j*b(i),
where i is the subcarrier index i ranging from 0 to NSC-1 and Df = 4.3125kHz
and (NSC-1) * Df is the highest frequency supported by the SELT-PMD functionality.
The scale factor shall be coded as a 16 bit unsigned integer.
Both a(i) and b(i) shall be coded as a 16 bit 2's complement signed integer.
The value of UER(i* f) shall be defined as UER(i* f) = (scale/215)*(a(i)+j*b(i))/215.
In order to maximize precision, the scale factor shall be chosen such that max(|a(i)|, |b(i)|)
over all i is equal to 215-1. This data format supports an UER(f) granularity of 2-15
and an UER(f) dynamic range of approximately +6 dB to -90 dB.
An UER(i*Df) value indicated as a(i) = b(i) = -215 is a special value.
It indicates that no measurement could be done for this subcarrier because
it is out of the PSD mask passband or that the value is out of range to be represented.
"
::= { hwBTSSAdslSeltTestEntry 23 }
hwBTSSAdslSeltTestParamVarUerC OBJECT-TYPE
SYNTAX OCTET STRING(SIZE(0..2048))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The relative variance of the uncalibrated echo response REL_VAR_UER(i* UER_G *Df) shall be
represented as an 8-bit unsigned integer v(i), where i is the subcarrier index i = 0 to NSC-1. The
value of REL_VAR_UER(i* UER_G *Df) shall be defined as REL_VAR_UER(i* UER_G *Df) = 3 - v(i)/2 dB.
The number v(i) is an 8-bit unsigned integer in the range 0 to 254.
This data format supports a REL_VAR_UER(i) over a range from -124 dB to +3 dB for each carrier with a granularity from 0.5 dB.
Out of range values shall be clamped to the closest range bound.
The special value v(i) = 255 indicates that no measurement is available for that carrier.
Unit: 0.5dB
"
::= { hwBTSSAdslSeltTestEntry 24 }
hwBTSSAdslSeltTestParamUerMmdC OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This parameter is the maximum allowed time for SELT uncalibrated echo response measurement,
between the time of the start command written by the SELT-PMD-ME, and the time the result is
available for read operation by SELT-PMD-ME.
It is configurable between 5 seconds and 240 seconds, in steps of 1 second.
The invalid value is 255. If data on the port cannot be queried, the invalid value will be returned.
Unit: 1 second
"
::= { hwBTSSAdslSeltTestEntry 25 }
hwBTSSAdslSeltTestParamQlnMmdC OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This parameter is the maximum allowed time for SELT quiet line noise measurement, between the
time of the start command written by the SELT-PMD-ME, and the time the result is available for
read operation by SELT-PMD-ME.
It is configurable between 1 second and 240 seconds, in steps of 1 second.
The invalid value is 255. If data on the port cannot be queried, the invalid value will be returned.
Unit: 1 second
"
::= { hwBTSSAdslSeltTestEntry 26 }
hwBTSSAdslSeltTestParamUmeC OBJECT-TYPE
SYNTAX INTEGER{enable(1),disable(2),invalid(-1)}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This parameter is a binary variable.
Options:
1.enable(1) - Enable UER capture switch
2.disable(2) - Disable UER capture switch
3.invalid(-1) - Invalid value
"
::= { hwBTSSAdslSeltTestEntry 27 }
hwBTSSAdslSeltTestParamQmeC OBJECT-TYPE
SYNTAX INTEGER{enable(1),disable(2),invalid(-1)}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This parameter is a binary variable.
Options:
1.enable(1) - Enable QLN capture switch
2.disable(2) - Disable QLN capture switch
3.invalid(-1) - Invalid value
"
::= { hwBTSSAdslSeltTestEntry 28 }
hwBTSSAdslSeltTestParamUerStatus OBJECT-TYPE
SYNTAX INTEGER{off(1), running(2),completed(3),failed(4)}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"UerStatus.
Options:
1.off(1) - The status is off.
2.running(2) - The status is running.
3.completed(3) - The status is completed.
4.failed(4) - The status is failed.
"
::= { hwBTSSAdslSeltTestEntry 29 }
hwBTSSAdslSeltTestParamQlnStatus OBJECT-TYPE
SYNTAX INTEGER{off(1), running(2),completed(3),failed(4)}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"QlnStatus.
Options:
1.off(1) - The status is off.
2.running(2) - The status is running.
3.completed(3) - The status is completed.
4.failed(4) - The status is failed.
"
::= { hwBTSSAdslSeltTestEntry 30 }
hwBTSSAdslSeltTestParamCalcEnable OBJECT-TYPE
SYNTAX INTEGER
{
enable(1),
disable(2),
invalid(-1)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The status of calculation switch.
Options:
1. enable(1) - Enable calculation switch
2. disable(2) - Disable calculation switch
3. invalid(-1) - Invalid value
Default: enable(1)
"
DEFVAL { enable }
::= { hwBTSSAdslSeltTestEntry 31 }
hwBTSSAdslSeltTestParamAttnAt180KHZ OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1dB"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Selt test parameter attenuation at 180KHZ.
It ranges from -1100 to 0 units of 0.1dB(physical values
are -110 to 0 dB).
The invalid value is -1. If no SELT is performed, no SELT data is
generated because the SELT is incomplete, or no SELT data can be
obtained from the port because the SELT data is aged and cleared,
the invalid value will be returned.
Unit: 0.1dB
"
::= { hwBTSSAdslSeltTestEntry 65535 }
hwBTSSAdslSeltTestParamAttnAt300KHZ OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1dB"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Selt test parameter attenuation at 300KHZ.
It ranges from -1100 to 0 units of 0.1dB(physical values
are -110 to 0 dB).
The invalid value is -1. If no SELT is performed, no SELT data is
generated because the SELT is incomplete, or no SELT data can be
obtained from the port because the SELT data is aged and cleared,
the invalid value will be returned.
Unit: 0.1dB
"
::= { hwBTSSAdslSeltTestEntry 65536 }
hwBTSSAdslSeltTestParamQSPsdValue OBJECT-TYPE
SYNTAX OCTET STRING(SIZE(0..1024))
UNITS "0.5dBm/Hz"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The SELT quiet line noise provides the quiet line noise PSD as measured by the SELT-PMD
function (see clause A.1.1.2) for each sub-carrier frequency i * SELTQLN_G * Df where i ranges
from 0 to NSC-1, Df = 4.3125 kHz, and (NSC-1) * SELTQLN_G * Df is the highest frequency
supported by the SELT-PMD functionality. SELTQLN_G has two valid values: 1 and 2, indicating
whether the measurements were performed using a tone spacing of 4.3125 kHz or of 8.625 kHz. If
the SELT quiet line noise is being reported over a frequency range of 17.664 MHz or lower,
SELTQLN_G shall be set to 1. If the SELT quiet line noise is being reported over a frequency
range that is greater than 17.664 MHz, SELTQLN_G shall be set to 2.
SELT quiet line noise SELTQLN(i * SELTQLN_G * Df) shall be represented as an 8-bit unsigned
integer n(i), where i is the subcarrier index i = 0 to NSC-1. The value of
SELTQLN(i * SELTQLN_G * Df) shall be defined as SELTQLN(i * SELTQLN_G * Df ) =
-23 - (n(i)/2) dBm/Hz. This data format supports a SELTQLN(f) granularity of 0.5 dB and an
SELTQLN(f) dynamic range of -150 to -23 dBm/Hz.
Unit: 0.5dBm/Hz
"
::= { hwBTSSAdslSeltTestEntry 65537 }
hwBTSSAdslDeltTestTable OBJECT-TYPE
SYNTAX SEQUENCE OF HWBTSSAdslDeltTestEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table describes Delt test for adsl2+.
The index of this table is ifIndex.
"
::= { hwBTestMIBObjects 22 }
hwBTSSAdslDeltTestEntry OBJECT-TYPE
SYNTAX HWBTSSAdslDeltTestEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table describes Delt test for adsl2+.
The index of this entry is ifIndex.
"
INDEX
{
ifIndex
}
::= { hwBTSSAdslDeltTestTable 1 }
HWBTSSAdslDeltTestEntry ::=
SEQUENCE
{
hwBTSSAdslDeltTestOperType INTEGER ,
hwBTSSAdslDeltTestOperResult INTEGER ,
hwBTSSAdslDeltTestResultNo Integer32 ,
hwBTSSAdslDeltTestResultLastFlag INTEGER ,
hwBTSSAdslDeltTestResult OCTET STRING
}
hwBTSSAdslDeltTestOperType OBJECT-TYPE
SYNTAX INTEGER
{
stop(1),
start(2),
invalid(-1)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Delt test operation type.
Options:
1. stop(1) - Delt test stop
2. start(2) - Start delt test
3. invalid(-1) - No operation
"
::= { hwBTSSAdslDeltTestEntry 1 }
hwBTSSAdslDeltTestOperResult OBJECT-TYPE
SYNTAX INTEGER
{
normal(1),
fail(2),
abort(3)
}
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"Delt test operation result.
Options:
1. normal(1) - Delt test is normal
2. fail(2) - Fail in delt test
3. abort(3) - Delt test aborts
"
::= { hwBTSSAdslDeltTestEntry 2 }
hwBTSSAdslDeltTestResultNo OBJECT-TYPE
SYNTAX Integer32(1..255)
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"Delt test result serial number.
Range: 1-255
"
::= { hwBTSSAdslDeltTestEntry 3 }
hwBTSSAdslDeltTestResultLastFlag OBJECT-TYPE
SYNTAX INTEGER{false(0), true(1)}
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"Last package flag for test result.
Options:
1. false(0) - This is not the last package
2. true(1) - The last package
"
::= { hwBTSSAdslDeltTestEntry 4 }
hwBTSSAdslDeltTestResult OBJECT-TYPE
SYNTAX OCTET STRING(SIZE(0..1500))
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"Delt test result data."
::= { hwBTSSAdslDeltTestEntry 5 }
-- Loop line tone Begin
hwBTSSLoopLineToneOprTable OBJECT-TYPE
SYNTAX SEQUENCE OF HwBTSSLoopLineToneOprEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The table hwBTSSLoopLineToneOprTable is used to Loop Line Tone.
The index of this table is ifIndex.
"
::= { hwBTestMIBObjects 23 }
hwBTSSLoopLineToneOprEntry OBJECT-TYPE
SYNTAX HwBTSSLoopLineToneOprEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The table hwBTSSLoopLineToneOprTable is used to Loop Line Tone.
The index of this entry is ifIndex.
"
INDEX
{
ifIndex
}
::= { hwBTSSLoopLineToneOprTable 1 }
HwBTSSLoopLineToneOprEntry ::=
SEQUENCE
{
hwBTSSLoopLineToneOprType
INTEGER,
hwBTSSLoopLineToneIntensity
INTEGER,
hwBTSSLoopLineToneBusyFlag
INTEGER,
hwBTSSLoopLineToneResult
INTEGER
}
hwBTSSLoopLineToneOprType OBJECT-TYPE
SYNTAX INTEGER
{
check(1),
send(2),
stopsend(3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Operation type of BTSS loop line tone
Options:
1. check(1) - Indicates that checking the signal tone is started
2. send(2) - Indicates that sending the signal tone is started
3. stopsend(3) - Indicates that stopping sending the signal tone is started
"
::= { hwBTSSLoopLineToneOprEntry 1 }
hwBTSSLoopLineToneIntensity OBJECT-TYPE
SYNTAX INTEGER
{
fivedB(1),
tendB(2),
fifteendB(3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Tone intensity of BTSS loop line tone.
Options:
1. fivedB(1) - Tone intensity of BTSS is five dB
2. tendB(2) - Tone intensity of BTSS is ten dB
3. fifteendB(3) - Tone intensity of BTSS is fifteen dB
"
::= { hwBTSSLoopLineToneOprEntry 2 }
hwBTSSLoopLineToneBusyFlag OBJECT-TYPE
SYNTAX INTEGER
{
busyNoTest(1),
busyTest(2),
busystrenTest(3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Tested port force test of BTSS loop line tone.
Options:
1. busyNoTest(1) - No test on busy
2. busyTest(2) - Test on busy
3. busystrenTest(3) - Forced test on busy
"
::= { hwBTSSLoopLineToneOprEntry 3 }
hwBTSSLoopLineToneResult OBJECT-TYPE
SYNTAX INTEGER
{
succeed(1),
failed(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Operate result of BTSS loop line tone.
Options:
1. succeed(1) - The test of BTSS loop line tone is successful
2. failed(2) - Failed in BTSS loop line tone test
"
::= { hwBTSSLoopLineToneOprEntry 4 }
--loop line tone End
hwBTSSSeltAuxPortCfgTable OBJECT-TYPE
SYNTAX SEQUENCE OF HwBTSSSeltAuxPortCfgEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table sets assistance port for SELT.
The index of this table is hwBTSSSeltAuxedPortIfIndex.
"
::= { hwBTestMIBObjects 24 }
hwBTSSSeltAuxPortCfgEntry OBJECT-TYPE
SYNTAX HwBTSSSeltAuxPortCfgEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table sets assistance port for SELT.
The index of this entry is hwBTSSSeltAuxedPortIfIndex.
"
INDEX
{
hwBTSSSeltAuxedPortIfIndex
}
::= { hwBTSSSeltAuxPortCfgTable 1 }
HwBTSSSeltAuxPortCfgEntry ::=
SEQUENCE
{
hwBTSSSeltAuxedPortIfIndex
Integer32,
hwBTSSSeltAuxPortIfIndex
Integer32,
hwBTSSSeltAuxPortRowStatus
RowStatus
}
hwBTSSSeltAuxedPortIfIndex OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The ifindex of the Auxed port. If there is only one global Auxed port,
the value is 65535.
"
::= { hwBTSSSeltAuxPortCfgEntry 1 }
hwBTSSSeltAuxPortIfIndex OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Assistance port ifIndex"
::= { hwBTSSSeltAuxPortCfgEntry 2 }
hwBTSSSeltAuxPortRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Row status(add(4), delete(6)) of the Aux port."
::= { hwBTSSSeltAuxPortCfgEntry 3 }
-- 1.3.6.1.4.1.2011.6.21.3.1.1.25
hwBTSSAdslSeltLevelTable OBJECT-TYPE
SYNTAX SEQUENCE OF HwBTSSAdslSeltLevelEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table supports the configuration of adsl selt level.
The indexes of this table are hwFrameIndex and hwSlotIndex.
"
::= { hwBTestMIBObjects 25 }
-- 1.3.6.1.4.1.2011.6.21.3.1.1.25.1
hwBTSSAdslSeltLevelEntry OBJECT-TYPE
SYNTAX HwBTSSAdslSeltLevelEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table supports the configuration of adsl selt level.
The indexes of this entry are hwFrameIndex and hwSlotIndex.
"
INDEX { hwFrameIndex, hwSlotIndex }
::= { hwBTSSAdslSeltLevelTable 1 }
HwBTSSAdslSeltLevelEntry ::=
SEQUENCE
{
hwBTSSAdslSeltLevel
Integer32
}
-- 1.3.6.1.4.1.2011.6.21.3.1.1.25.1.1
hwBTSSAdslSeltLevel OBJECT-TYPE
SYNTAX Integer32 (-1 | 1..4)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The level of adsl SELT:
1 Level0;
2 Level1;
3 Level2;
4 Level3.
A special value of -1 indicates the level of adsl SELT is invalid.
"
::= { hwBTSSAdslSeltLevelEntry 1 }
-- 1.3.6.1.4.1.2011.6.21.3.1.1.26
hwBTSSAdslSeltCalibrationTable OBJECT-TYPE
SYNTAX SEQUENCE OF HWBTSSAdslSeltCalibrationtEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table describes calibration data of selt test.
The index of this table is ifIndex.
"
::= { hwBTestMIBObjects 26 }
hwBTSSAdslSeltCalibrationEntry OBJECT-TYPE
SYNTAX HWBTSSAdslSeltCalibrationtEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table describes calibration data of selt test.
The index of this entry is ifIndex.
"
INDEX
{
ifIndex
}
::= { hwBTSSAdslSeltCalibrationTable 1 }
HWBTSSAdslSeltCalibrationtEntry ::=
SEQUENCE
{
hwBTSSAdslSeltCalibrationInvVendorId OCTET STRING,
hwBTSSAdslSeltCalibrationDataSegment1 OCTET STRING,
hwBTSSAdslSeltCalibrationDataSegment2 OCTET STRING
}
-- 1.3.6.1.4.1.2011.6.21.3.1.1.26.1.1
hwBTSSAdslSeltCalibrationInvVendorId OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(8))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"It consists of 8 binary octets, including a
provider code.
"
::= { hwBTSSAdslSeltCalibrationEntry 1 }
hwBTSSAdslSeltCalibrationDataSegment1 OBJECT-TYPE
SYNTAX OCTET STRING(SIZE(0..8192))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The part 1 of selt calibration data.
The unit of selt calibration data is 0.00001.
"
::= { hwBTSSAdslSeltCalibrationEntry 2 }
hwBTSSAdslSeltCalibrationDataSegment2 OBJECT-TYPE
SYNTAX OCTET STRING(SIZE(0..8192))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The part 2 of selt calibration data.
The unit of selt calibration data is 0.00001.
"
::= { hwBTSSAdslSeltCalibrationEntry 3 }
hwBTestTraps OBJECT IDENTIFIER ::= { hwBTest 2 }
hwBTestTrapVbOids OBJECT IDENTIFIER ::= { hwBTestTraps 1 }
hwBTestVbOidsReason OBJECT IDENTIFIER ::= { hwBTestTrapVbOids 2 }
hwBTSSCqtOfflineReason OBJECT-TYPE
SYNTAX INTEGER
{
commFail(1),
userReset(2)
}
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"Cqt module offline reason.
Options:
1. commFail(1) - CQT module communication fail. Resolving method:Check CQT module running normal
2. userReset(2) - User reset command
"
::= { hwBTestVbOidsReason 1 }
hwBTSSRequestID OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"NMS request ID."
::= { hwBTestVbOidsReason 2 }
hwBTestAlarmTraps OBJECT IDENTIFIER ::= { hwBTestTraps 2 }
hwBTestAlarmTrapsOIDs OBJECT IDENTIFIER ::= { hwBTestAlarmTraps 0 }
hwBTSSCqtOnlineTrap NOTIFICATION-TYPE
OBJECTS { ifIndex }
STATUS current
DESCRIPTION
"CQT unit online status trap.
This notification indicates alarm when CQT unit online.
enumFirst:
explain: CQT module communication OK
resolving method:NA.
"
::= { hwBTestAlarmTrapsOIDs 1 }
hwBTSSCqtOfflineTrap NOTIFICATION-TYPE
OBJECTS { ifIndex, hwBTSSCqtOfflineReason }
STATUS current
DESCRIPTION
"CQT unit offline status trap.
This notification indicates alarm when CQT unit offline.
"
::= { hwBTestAlarmTrapsOIDs 2 }
hwBTestGeneralTraps OBJECT IDENTIFIER ::= { hwBTestTraps 3 }
hwBTestGeneralTrapsOIDs OBJECT IDENTIFIER ::= { hwBTestGeneralTraps 0 }
hwBTSSCoStartTrap NOTIFICATION-TYPE
OBJECTS { ifIndex, hwBTSSCoOperType, hwBTSSCoTestResult }
STATUS current
DESCRIPTION
"Start Co test trap.
This notification indicates alarm when starting Co test.
"
::= { hwBTestGeneralTrapsOIDs 1 }
hwBTSSCoStopTrap NOTIFICATION-TYPE
OBJECTS { ifIndex, hwBTSSCoOperType, hwBTSSCoTestResult }
STATUS current
DESCRIPTION
"Stop Co test trap.
This notification indicates alarm when stopping Co test.
"
::= { hwBTestGeneralTrapsOIDs 2 }
hwBTSSTestedPortOperTrap NOTIFICATION-TYPE
OBJECTS { ifIndex,hwBTSSTestedPortOperType,hwBTSSTestedPortOperMode,hwBTSSTestedPortOperResult }
STATUS current
DESCRIPTION
"Tested port operation trap.
This notification indicates alarm when tested port operation.
"
::= { hwBTestGeneralTrapsOIDs 3 }
hwBTSSCqtTransTestOperResultTrap NOTIFICATION-TYPE
OBJECTS { ifIndex,hwBTSSCqtTransTestOperType,hwBTSSCqtTransTestOperResult }
STATUS current
DESCRIPTION
"Cqt transparent test trap.
This notification indicates alarm when starting or stoping Cqt transparent test.
"
::= { hwBTestGeneralTrapsOIDs 4 }
hwBTSSCqtTransTestResultTrap NOTIFICATION-TYPE
OBJECTS { ifIndex,hwBTSSCqtTransTestResultLastFlag,hwBTSSCqtTransTestResultNo,hwBTSSCqtTransTestResult }
STATUS current
DESCRIPTION
"Cqt transparent test trap.
This notification indicates alarm when reporting the result after Cqt transparent test.
"
::= { hwBTestGeneralTrapsOIDs 5 }
hwBTSSLoopLineToneOperTrap NOTIFICATION-TYPE
OBJECTS { hwBTSSLoopLineToneResult }
STATUS current
DESCRIPTION
"loop line tone test result trap: 1:hwBTSSLoopLineToneResult.
This notification indicates alarm when reporting the test result of Loop Line Tone.
"
::= { hwBTestGeneralTrapsOIDs 6 }
hwBTSSCaptureTrap NOTIFICATION-TYPE
OBJECTS
{
hwBTSSRequestID,
ifIndex,
hwBTSSTestedPortOperType,
hwBTSSTestedPortOperMode,
hwBTSSTestedPortOperResult
}
STATUS current
DESCRIPTION
"BTSS capture trap.
This trap is sent when BTSS capture result reported.
"
::= { hwBTestGeneralTrapsOIDs 7 }
hwBTSSDeltResultDataTrap NOTIFICATION-TYPE
OBJECTS
{
hwBTSSAdslDeltTestResultNo,
hwBTSSRequestID,
ifIndex,
hwBTSSAdslDeltTestResultLastFlag,
hwBTSSAdslDeltTestResult
}
STATUS current
DESCRIPTION
"BTSS delt result trap.
This notification indicates alarm when captures result data of BTSS delt test.
"
::= { hwBTestGeneralTrapsOIDs 8 }
END