-- Copyright (C) 2010 by HUAWEI TECHNOLOGIES. All rights reserved.
|
|
-- Description: The MIB module defining objects for the management of a pair of ATM modems
|
|
-- at each end of the ATM line.
|
|
-- Reference:
|
|
-- Version: V3.07
|
|
-- ============================================================================
|
|
HUAWEI-ATM-OAM-MIB DEFINITIONS ::= BEGIN
|
|
|
|
IMPORTS
|
|
AtmVpIdentifier, AtmVcIdentifier
|
|
FROM ATM-TC-MIB
|
|
huaweiUtility
|
|
FROM HUAWEI-MIB
|
|
ifIndex
|
|
FROM IF-MIB
|
|
OBJECT-TYPE, MODULE-IDENTITY, NOTIFICATION-TYPE,Integer32
|
|
FROM SNMPv2-SMI
|
|
DateAndTime, RowStatus
|
|
FROM SNMPv2-TC;
|
|
|
|
hwAtmOam MODULE-IDENTITY
|
|
LAST-UPDATED "201011090000Z"
|
|
ORGANIZATION "Huawei Technologies Co.,Ltd."
|
|
CONTACT-INFO
|
|
"Huawei Industrial Base
|
|
Bantian, Longgang
|
|
Shenzhen 518129
|
|
People's Republic of China
|
|
Website: http://www.huawei.com
|
|
Email: support@huawei.com
|
|
"
|
|
DESCRIPTION
|
|
"The MIB module defining objects for the management of a pair of ATM modems
|
|
at each end of the ATM line.
|
|
"
|
|
|
|
-- Revision history
|
|
REVISION "201011090000Z"
|
|
DESCRIPTION "V3.07, modified the description of MIB."
|
|
|
|
REVISION "201007290000Z"
|
|
DESCRIPTION "V3.06, modified the description of MIB."
|
|
|
|
REVISION "201002080000Z"
|
|
DESCRIPTION "V3.05, added the definition of the trap node."
|
|
|
|
REVISION "201001100000Z"
|
|
DESCRIPTION "V3.04, added the definition of the trap node."
|
|
|
|
REVISION "200812240000Z"
|
|
DESCRIPTION "V3.03, changed the hwAtmOamLbNumber value range from 1-10 to 1-65535."
|
|
|
|
REVISION "200805310000Z"
|
|
DESCRIPTION "V3.02, deleted chinese character."
|
|
|
|
REVISION "200304280000Z"
|
|
DESCRIPTION "V3.00, added file head and modified MODULE-IDENTITY. "
|
|
|
|
REVISION "200209260000Z"
|
|
DESCRIPTION
|
|
"V1.00, initial version."
|
|
::= { huaweiUtility 11 }
|
|
|
|
hwAtmOamMibObjects OBJECT IDENTIFIER ::= { hwAtmOam 1 }
|
|
|
|
hwAtmOamPointTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF HwAtmOamPointEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Table of OAM point.
|
|
The indexes of this table are ifIndex,hwAtmOamPointVPI and hwAtmOamPointVCI.
|
|
"
|
|
::= { hwAtmOamMibObjects 1 }
|
|
|
|
hwAtmOamPointEntry OBJECT-TYPE
|
|
SYNTAX HwAtmOamPointEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Table of OAM point.
|
|
The indexes of this entry are ifIndex,hwAtmOamPointVPI and hwAtmOamPointVCI.
|
|
"
|
|
INDEX { ifIndex,hwAtmOamPointVPI, hwAtmOamPointVCI }
|
|
::= { hwAtmOamPointTable 1 }
|
|
|
|
HwAtmOamPointEntry ::=
|
|
SEQUENCE {
|
|
hwAtmOamPointVPI
|
|
AtmVpIdentifier,
|
|
hwAtmOamPointVCI
|
|
AtmVcIdentifier,
|
|
hwAtmOamPointType
|
|
INTEGER,
|
|
hwAtmOamPointAdminStatus
|
|
INTEGER,
|
|
hwAtmOamAlarmType
|
|
INTEGER,
|
|
hwAtmOamCfgFlag
|
|
INTEGER,
|
|
hwAtmOamFmStatus
|
|
INTEGER,
|
|
hwAtmOamFmStatusDateTime
|
|
DateAndTime,
|
|
hwAtmOamPointRowStatus
|
|
RowStatus
|
|
}
|
|
|
|
hwAtmOamPointVPI OBJECT-TYPE
|
|
SYNTAX AtmVpIdentifier
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"vpi."
|
|
::= { hwAtmOamPointEntry 1 }
|
|
|
|
hwAtmOamPointVCI OBJECT-TYPE
|
|
SYNTAX AtmVcIdentifier
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"vci.
|
|
If vci = 0, it means that this is a F4 point"
|
|
::= { hwAtmOamPointEntry 2 }
|
|
|
|
hwAtmOamPointType OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
e2e(1),
|
|
segment(2),
|
|
e2eInter(3),
|
|
segmentInter(4)
|
|
}
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"OAM point type.
|
|
Options:
|
|
1. e2e(1) -e-t-e end point
|
|
2. segment(2) -segment end point
|
|
3. e2eInter(3) -connection point within two e-t-e points
|
|
4. segmentInter(4) -connection point within two segment points
|
|
"
|
|
DEFVAL { segment }
|
|
::= { hwAtmOamPointEntry 3 }
|
|
|
|
hwAtmOamPointAdminStatus OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
up(1),
|
|
down(2)
|
|
}
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"up(1) means enable; down(2) means disable.
|
|
Options:
|
|
1. up(1) -enable
|
|
2. down(2) -disable
|
|
"
|
|
DEFVAL { up }
|
|
::= { hwAtmOamPointEntry 4 }
|
|
|
|
hwAtmOamAlarmType OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
noAlarm(0),
|
|
receiveAisCell(1),
|
|
receiveRdiCell(2),
|
|
loc(4),
|
|
f4Ais(8),
|
|
portAlarm(16)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"OAM point alarm type.
|
|
Options:
|
|
1. noAlarm(0) -no alarm
|
|
2. receiveAisCell(1) -received AIS cell
|
|
3. receiveRdiCell(2) -received RDI cell
|
|
4.loc(4) -lost of continuity (CC failed)
|
|
5.f4Ais(8) -F4 layer AIS alarm. only for F5 point
|
|
6.portAlarm(16) -F1~F3 layer alarm
|
|
All Alarms can happen at same time which displayed as the relate bit.
|
|
"
|
|
::= { hwAtmOamPointEntry 5 }
|
|
|
|
hwAtmOamCfgFlag OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
running(1),
|
|
recovering(2)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"OAM point configure recovering flag.
|
|
Options:
|
|
1.running(1) -OAM point in running stage
|
|
2.recovering(2) -OAM point in recovering stage
|
|
"
|
|
::= { hwAtmOamPointEntry 6 }
|
|
|
|
hwAtmOamFmStatus OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
normal(1),
|
|
ais(2),
|
|
rdi(3)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"OAM point FM status.
|
|
Options:
|
|
1. normal(1) -FM status is normal
|
|
2. ais(2) -FM status is ais
|
|
3. rdi(3) -FM status is rdi
|
|
"
|
|
::= { hwAtmOamPointEntry 7 }
|
|
|
|
hwAtmOamFmStatusDateTime OBJECT-TYPE
|
|
SYNTAX DateAndTime
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The time when the OAM point entered this FM status."
|
|
::= { hwAtmOamPointEntry 8 }
|
|
|
|
hwAtmOamPointRowStatus OBJECT-TYPE
|
|
SYNTAX RowStatus
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"OAM point table row status."
|
|
::= { hwAtmOamPointEntry 9 }
|
|
|
|
hwAtmOamCcTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF HwAtmOamCcEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Table of CC end point.
|
|
Refer to the definition of the OAM point table.
|
|
The indexes of this table are ifIndex,hwAtmOamCcVPI and hwAtmOamCcVCI.
|
|
"
|
|
::= { hwAtmOamMibObjects 2 }
|
|
|
|
hwAtmOamCcEntry OBJECT-TYPE
|
|
SYNTAX HwAtmOamCcEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Table of CC end point.
|
|
Refer to the definition of the OAM point table.
|
|
The indexes of this entry are ifIndex,hwAtmOamCcVPI and hwAtmOamCcVCI.
|
|
"
|
|
INDEX { ifIndex,hwAtmOamCcVPI, hwAtmOamCcVCI }
|
|
::= { hwAtmOamCcTable 1 }
|
|
|
|
HwAtmOamCcEntry ::=
|
|
SEQUENCE {
|
|
hwAtmOamCcVPI
|
|
AtmVpIdentifier,
|
|
hwAtmOamCcVCI
|
|
AtmVcIdentifier,
|
|
hwAtmOamCcDirection
|
|
INTEGER,
|
|
hwAtmOamConfType
|
|
INTEGER,
|
|
hwAtmOamCcAdminStatus
|
|
INTEGER,
|
|
hwAtmOamCcRowStatus
|
|
RowStatus
|
|
}
|
|
|
|
hwAtmOamCcVPI OBJECT-TYPE
|
|
SYNTAX AtmVpIdentifier
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"vpi."
|
|
::= { hwAtmOamCcEntry 1 }
|
|
|
|
hwAtmOamCcVCI OBJECT-TYPE
|
|
SYNTAX AtmVcIdentifier
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"vci.
|
|
If vci = 0, it means that this is a F4 point"
|
|
::= { hwAtmOamCcEntry 2 }
|
|
|
|
hwAtmOamCcDirection OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
sink(1),
|
|
source(2),
|
|
both(3)
|
|
}
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"OAM CC direction.
|
|
Options:
|
|
1. sink(1) -OAM CC direction is sink
|
|
2. source(2) -OAM CC direction is source
|
|
3. both(3) -OAM CC direction is both
|
|
"
|
|
DEFVAL { both }
|
|
::= { hwAtmOamCcEntry 3 }
|
|
|
|
hwAtmOamConfType OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
autoConfig(1),
|
|
manualConfig(2)
|
|
}
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"OAM CC configure type,only valid for up or down operating.
|
|
Options:
|
|
1. autoConfig(1) -active/deactive CC by A/D protocol
|
|
2. manualConfig(2) -active/deactive CC by TMN entirely. see I.610
|
|
"
|
|
DEFVAL { manualConfig }
|
|
::= { hwAtmOamCcEntry 4 }
|
|
|
|
hwAtmOamCcAdminStatus OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
up(1),
|
|
down(2)
|
|
}
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"up(1) means enable; down(2) means disable.
|
|
Options:
|
|
1. up(1) -enable
|
|
2. down(2) -disable
|
|
"
|
|
DEFVAL { up }
|
|
::= { hwAtmOamCcEntry 5 }
|
|
|
|
hwAtmOamCcRowStatus OBJECT-TYPE
|
|
SYNTAX RowStatus
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"OAM CC end point table row status."
|
|
::= { hwAtmOamCcEntry 6 }
|
|
|
|
hwAtmOamLbTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF HwAtmOamLbEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Table of ATM OAM loopback, it is used for setting flow loopback.
|
|
The indexes of this table are ifIndex,hwAtmOamLbVPI and hwAtmOamLbVCI.
|
|
"
|
|
::= { hwAtmOamMibObjects 3 }
|
|
|
|
hwAtmOamLbEntry OBJECT-TYPE
|
|
SYNTAX HwAtmOamLbEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Table of ATM OAM loopback, it is used for setting flow loopback.
|
|
The indexes of this entry are ifIndex,hwAtmOamLbVPI and hwAtmOamLbVCI.
|
|
"
|
|
INDEX { ifIndex,hwAtmOamLbVPI, hwAtmOamLbVCI }
|
|
::= { hwAtmOamLbTable 1 }
|
|
|
|
HwAtmOamLbEntry ::=
|
|
SEQUENCE {
|
|
hwAtmOamLbVPI
|
|
AtmVpIdentifier,
|
|
hwAtmOamLbVCI
|
|
AtmVcIdentifier,
|
|
hwAtmOamLbType
|
|
INTEGER,
|
|
hwAtmOamLbPointLLID
|
|
OCTET STRING,
|
|
hwAtmOamLbNumber
|
|
Integer32,
|
|
hwAtmOamLbInterval
|
|
Integer32
|
|
}
|
|
|
|
hwAtmOamLbVPI OBJECT-TYPE
|
|
SYNTAX AtmVpIdentifier
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Vpi of the OAM loopback flow."
|
|
::= { hwAtmOamLbEntry 1 }
|
|
|
|
hwAtmOamLbVCI OBJECT-TYPE
|
|
SYNTAX AtmVcIdentifier
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Vci of the OAM loopback flow.
|
|
If vci = 0, means that this is a F4 point.
|
|
"
|
|
::= { hwAtmOamLbEntry 2 }
|
|
|
|
hwAtmOamLbType OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
e2e(1),
|
|
segment(2),
|
|
llid(3),
|
|
noloopback(4)
|
|
}
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"OAM loopback type.
|
|
Options:
|
|
1. e2e(1) -end to end loopback
|
|
2. segment(2) -segment loopback
|
|
3. llid(3) -specified llid loopback
|
|
4. noloopback(4) -stopping loopback
|
|
"
|
|
DEFVAL { segment }
|
|
::= { hwAtmOamLbEntry 3 }
|
|
|
|
hwAtmOamLbPointLLID OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (0..16))
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Specify loopback destination LLID.
|
|
It is valid to be set llid(3) for hwAtmOamLbType only.
|
|
"
|
|
::= { hwAtmOamLbEntry 4 }
|
|
|
|
hwAtmOamLbNumber OBJECT-TYPE
|
|
SYNTAX Integer32 (1..65535)
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Specify the number of the cells loopbacked.
|
|
"
|
|
::= { hwAtmOamLbEntry 5 }
|
|
|
|
hwAtmOamLbInterval OBJECT-TYPE
|
|
SYNTAX Integer32 (1..5)
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Specify the interval between two insert operation. "
|
|
::= { hwAtmOamLbEntry 6 }
|
|
|
|
hwAtmOamLlidTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF HwAtmOamLlidEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Table of OAM LLID.
|
|
The index of this table is ifIndex.
|
|
"
|
|
::= { hwAtmOamMibObjects 4 }
|
|
|
|
hwAtmOamLlidEntry OBJECT-TYPE
|
|
SYNTAX HwAtmOamLlidEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Table of OAM LLID.
|
|
The index of this entry is ifIndex.
|
|
"
|
|
INDEX { ifIndex }
|
|
::= { hwAtmOamLlidTable 1 }
|
|
|
|
HwAtmOamLlidEntry ::=
|
|
SEQUENCE {
|
|
hwAtmOamLlidPointLLID
|
|
OCTET STRING
|
|
}
|
|
|
|
hwAtmOamLlidPointLLID OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (0..16))
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"local interface LLID. "
|
|
::= { hwAtmOamLlidEntry 1 }
|
|
|
|
hwAtmOamInsertTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF HwAtmOamInsertEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Table of OAM Insert.
|
|
This table only support 'set' operation.
|
|
The indexes of this table are ifIndex,hwAtmOamInsertVPI and hwAtmOamInsertVCI.
|
|
"
|
|
::= { hwAtmOamMibObjects 5 }
|
|
|
|
hwAtmOamInsertEntry OBJECT-TYPE
|
|
SYNTAX HwAtmOamInsertEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Table of OAM Insert.
|
|
This table only support 'set' operation.
|
|
The indexes of this entry are ifIndex,hwAtmOamInsertVPI and hwAtmOamInsertVCI.
|
|
"
|
|
INDEX { ifIndex,hwAtmOamInsertVPI, hwAtmOamInsertVCI }
|
|
::= { hwAtmOamInsertTable 1 }
|
|
|
|
HwAtmOamInsertEntry ::=
|
|
SEQUENCE {
|
|
hwAtmOamInsertVPI
|
|
AtmVpIdentifier,
|
|
hwAtmOamInsertVCI
|
|
AtmVcIdentifier,
|
|
hwAtmOamInsertOperation
|
|
INTEGER,
|
|
hwAtmOamInsertSegment
|
|
INTEGER,
|
|
hwAtmOamInsertCellType
|
|
INTEGER
|
|
}
|
|
|
|
hwAtmOamInsertVPI OBJECT-TYPE
|
|
SYNTAX AtmVpIdentifier
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"vpi."
|
|
::= { hwAtmOamInsertEntry 1 }
|
|
|
|
hwAtmOamInsertVCI OBJECT-TYPE
|
|
SYNTAX AtmVcIdentifier
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"vci.
|
|
if vci = 0, means that this is a F4 point."
|
|
::= { hwAtmOamInsertEntry 2 }
|
|
|
|
hwAtmOamInsertOperation OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
start(1),
|
|
stop(2)
|
|
}
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"specify the operation(begin or stop) of the insertion.
|
|
Options:
|
|
1. start(1) -the operation of the insertion is begin
|
|
2. stop(2) -the operation of the insertion is stop
|
|
"
|
|
::= { hwAtmOamInsertEntry 3 }
|
|
|
|
hwAtmOamInsertSegment OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
segment(1),
|
|
end(2)
|
|
}
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"specify the segment type.
|
|
Options:
|
|
1. segment(1) -specify the segment type is segment
|
|
2. end(2) -specify the segment type is end
|
|
"
|
|
::= { hwAtmOamInsertEntry 4 }
|
|
|
|
hwAtmOamInsertCellType OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
ais(1),
|
|
rdi(2),
|
|
cc(3)
|
|
}
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"specify the type of the inserted cell.
|
|
Options:
|
|
1. ais(1) -specify the type of the inserted cell is ais
|
|
2. rdi(2) -specify the type of the inserted cell is rdi
|
|
3. cc(3) -specify the type of the inserted cell is cc
|
|
"
|
|
::= { hwAtmOamInsertEntry 5 }
|
|
|
|
hwAtmOamTraps OBJECT IDENTIFIER ::= { hwAtmOam 2 }
|
|
|
|
hwAtmOamTrapVarBindOids OBJECT IDENTIFIER ::= { hwAtmOamTraps 1 }
|
|
|
|
hwAtmOamGeneralVarBindOids OBJECT IDENTIFIER ::= { hwAtmOamTrapVarBindOids 1 }
|
|
|
|
hwAtmOamVarBindLoopbackResult OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
success(1),
|
|
timeout(2)
|
|
}
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Loopback result.
|
|
Options:
|
|
1. success(1) -loopback success
|
|
2. timeout(2) -not received loopback cell for 5 seconds after sent
|
|
"
|
|
::= { hwAtmOamGeneralVarBindOids 1 }
|
|
|
|
hwAtmOamVarBindOidsReason OBJECT IDENTIFIER ::= { hwAtmOamTrapVarBindOids 2 }
|
|
|
|
hwAtmOamAisReason OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
connDelete(1),
|
|
boardFail(2)
|
|
}
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"OAM operation terminate reason.
|
|
Options:
|
|
1. connDelete(1) -ATM connection be deleted
|
|
2. boardFail(2) -Board fail
|
|
"
|
|
::= { hwAtmOamVarBindOidsReason 1 }
|
|
|
|
hwAtmOamOperTerminateReason OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
connDelete(1),
|
|
boardFail(2)
|
|
}
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"OAM operation terminate reason:
|
|
Options:
|
|
1. connDelete(1) -ATM connection be deleted
|
|
2. boardFail(2) -Board fail
|
|
"
|
|
::= { hwAtmOamVarBindOidsReason 2 }
|
|
|
|
hwAtmOamAlarmTraps OBJECT IDENTIFIER ::= { hwAtmOamTraps 2 }
|
|
|
|
hwAtmOamAlarmTrapsOids OBJECT IDENTIFIER ::= { hwAtmOamAlarmTraps 0 }
|
|
|
|
hwAtmOamAlarmAis NOTIFICATION-TYPE
|
|
OBJECTS { ifIndex, hwAtmOamPointVPI, hwAtmOamPointVCI }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This trap will send when there is some defect in the upstream.
|
|
alarm description:AIS alarm.
|
|
explain: AIS cell received from upstream.
|
|
resolving method:Check if there is some defect in the upstream.
|
|
"
|
|
::= { hwAtmOamAlarmTrapsOids 1 }
|
|
|
|
hwAtmOamAlarmAisRestore NOTIFICATION-TYPE
|
|
OBJECTS { ifIndex, hwAtmOamPointVPI, hwAtmOamPointVCI }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This trap will send when there is no AIS cell received from upstream within a time interval of 2.5 seconds, with a margin of 0.5 seconds.
|
|
alarm description: AIS alarm restore.
|
|
explain: There is no AIS cell received from upstream within a time interval of 2.5 seconds, with a margin of 0.5 seconds.
|
|
resolving method:NA.
|
|
"
|
|
::= { hwAtmOamAlarmTrapsOids 2 }
|
|
|
|
hwAtmOamAlarmRdi NOTIFICATION-TYPE
|
|
OBJECTS { ifIndex, hwAtmOamPointVPI, hwAtmOamPointVCI }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This trap will send when there is some defect in the downstream.
|
|
alarm description:RDI alarm.
|
|
explain: RDI cell received from downstream.
|
|
resolving method:Check if there is some defect in the downstream.
|
|
"
|
|
::= { hwAtmOamAlarmTrapsOids 3 }
|
|
|
|
hwAtmOamAlarmRdiRestore NOTIFICATION-TYPE
|
|
OBJECTS { ifIndex, hwAtmOamPointVPI, hwAtmOamPointVCI }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This trap will send when there is no RDI cell received from downstream within a time interval of 2.5 seconds, with a margin of 0.5 seconds.
|
|
alarm description:RDI alarm restore
|
|
explain: There is no RDI cell received from downstream within a time interval of 2.5 seconds, with a margin of 0.5 seconds.
|
|
resolving method:NA.
|
|
"
|
|
::= { hwAtmOamAlarmTrapsOids 4 }
|
|
|
|
hwAtmOamAlarmLoc NOTIFICATION-TYPE
|
|
OBJECTS { ifIndex, hwAtmOamPointVPI, hwAtmOamPointVCI }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This trap will send when CC sink can not receive CC cells from source within a time interval of 3.5 seconds,with a margin of 0.5 seconds;Or physical fault is detected.
|
|
alarm description:LOC alarm.
|
|
explain: CC sink can not receive CC cells from source within a time interval of 3.5 seconds,with a margin of 0.5 seconds;Or physical fault is detected.
|
|
resolving method:Check if there is some physical fault.check if there is some defect between CC source and CC sink.check if CC source is configured correctly.
|
|
"
|
|
::= { hwAtmOamAlarmTrapsOids 5 }
|
|
|
|
hwAtmOamAlarmLocRestore NOTIFICATION-TYPE
|
|
OBJECTS { ifIndex, hwAtmOamPointVPI, hwAtmOamPointVCI }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This trap will send when CC cells can be received from CC source.Or physical fault is restored.
|
|
alarm description:LOC alarm restore.
|
|
explain: CC cells can be received from CC source.Or physical fault is restored.
|
|
resolving method:NA.
|
|
"
|
|
::= { hwAtmOamAlarmTrapsOids 6 }
|
|
|
|
hwAtmOamAlarmLbTerminate NOTIFICATION-TYPE
|
|
OBJECTS { ifIndex, hwAtmOamPointVPI, hwAtmOamPointVCI, hwAtmOamOperTerminateReason }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This trap will send when the corresponding connection is deleted or there is some fault in the corresponding board.
|
|
alarm description:LB abort alarm.
|
|
explain: 1.The corresponding connection is deleted.
|
|
2.There is some fault in the corresponding board.
|
|
resolving method:Until the board changes normal, and renew configuring if necessary.
|
|
|
|
"
|
|
::= { hwAtmOamAlarmTrapsOids 7 }
|
|
|
|
hwAtmOamAlarmInsTerminate NOTIFICATION-TYPE
|
|
OBJECTS { ifIndex, hwAtmOamPointVPI, hwAtmOamPointVCI, hwAtmOamOperTerminateReason }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This trap will send when the corresponding connection is deleted or there is some fault in the corresponding board.
|
|
alarm description:Insertion abort alarm.
|
|
explain: 1.The corresponding connection is deleted.
|
|
2.There is some fault in the corresponding board.
|
|
resolving method:Until the board changes normal, and renew configuring if necessary.
|
|
"
|
|
::= { hwAtmOamAlarmTrapsOids 8 }
|
|
|
|
hwAtmOamGeneralTraps OBJECT IDENTIFIER ::= { hwAtmOamTraps 3 }
|
|
|
|
hwAtmOamGeneralTrapsOids OBJECT IDENTIFIER ::= { hwAtmOamGeneralTraps 0 }
|
|
|
|
hwAtmOamTrapLoopbackReport NOTIFICATION-TYPE
|
|
OBJECTS { hwAtmOamLbPointLLID, hwAtmOamVarBindLoopbackResult, hwAtmOamLbVPI, hwAtmOamLbVCI, ifIndex
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This trap will send when the loopback result of LB cell return.
|
|
General trap description:
|
|
Used to send loopback result of LB cell, success(1) or timeout(2).
|
|
"
|
|
::= { hwAtmOamGeneralTrapsOids 1 }
|
|
|
|
hwAtmOamPingLoopTestTrap NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
ifIndex,
|
|
hwAtmOamLbVPI ,
|
|
hwAtmOamLbVCI,
|
|
hwAtmOamLbCurrentNumber,
|
|
hwAtmOamLbCurrentResult
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The trap whill send when the ATM ping loop test finished."
|
|
::= { hwAtmOamGeneralTrapsOids 2 }
|
|
|
|
|
|
hwAtmOamTrapsVbOids OBJECT IDENTIFIER ::= { hwAtmOam 3 }
|
|
|
|
hwAtmOamLbCurrentNumber OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The current atmping number."
|
|
::= { hwAtmOamTrapsVbOids 1 }
|
|
|
|
hwAtmOamLbCurrentResult OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The current atmping result.
|
|
Options:
|
|
1. successful(0) -the current atmping successful
|
|
2. timeout(1) -the current atmping timeout
|
|
3. boardfailed(2) -the board failed
|
|
"
|
|
::= { hwAtmOamTrapsVbOids 2 }
|
|
|
|
END
|
|
|
|
|