-- (C) COPYRIGHT HEWLETT-PACKARD COMPANY 1997.
--
-- LaserJet 5Si Mopier Printer Model Specific MIB.
--
-- Generated on August 4, 1997.
--
-- Company names and product names mentioned herein may be
-- trademarks, and/or registered trademarks of their respective
-- companies.
--
-- For interal and external use.
--
-- This MIB describes all the printer model specific
-- objects suppported by the LaserJet 5Si Mopier printer
-- when networked connected using a JetDirect print
-- server.
--
-- The following MIB also contain objects supported
-- by a JetDirect connected LaserJet 5Si Mopier printer:
--
-- rfc 1213 MIB II
--
-- This MIB complies with the following RFCs:
--
-- rfc 1157 Simple Network Management Protocol
-- rfc 1155 Structure of Management Information
--
-- Notes:
--
-- 1) At the time this MIB was published, a
-- defect existed where the printer would not correctly
-- handle an SNMP get next request. The printer
-- behavior is correct for tabular objects, but not
-- scalar objects. For example, energy-star, sleep-mode,
-- and on-off-line are all scalars with OIDS:
--
-- energy-star { dm 1 1 1 1 }
-- sleep-mode { dm 1 1 1 2 }
-- on-off-line { dm 1 2 2 5 }
--
-- These three objects are the first three objects supported
-- under the dm tree.
--
-- The printer operation (using OpenView tools as an
-- example) is:
--
-- snmpnext hpb18207 .1.3.6.1.4.1.11.2.3.9.4.2.1.1.1.2.0
--
-- with a reply of:
--
-- hp.nm.hpsystem.net-peripheral.netdm.dm.device.system.status-system.
-- on-off-line.0 : INTEGER: eOnline
--
-- which the printer handles correctly.
--
-- However, if the zero is left off the end, then the printer operation
-- is:
--
-- snmpnext hpb18207 .1.3.6.1.4.1.11.2.3.9.4.2.1.1.1.2
--
-- with a reply of:
--
-- hp.nm.hpsystem.net-peripheral.netdm.dm.device.system.status-system.
-- on-off-line.0 : INTEGER: eOnline
--
-- which is incorrect. The object that should have been returned is
-- the energy-star object, not the on-off-line object.
--
-- Since the OpenView MIB Browser uses the get next command in an
-- attempt to retrieve all the supported objects under the specified OID
-- =======================
-- (object identifier) and the printer returns an object that is not under
-- the specified OID, the MIB Browser assumes there are no objects
-- supported under the specified OID and reports "no value (s) returned for
-- query".
--
-- If you use an SNMP tool other than OpenView MIB Browser to do a get,
-- the printer properly responds.
--
-- Retrieving tables using the OpenView MIB Browser works fine. Only
-- retrieving scalar objects fails.
--
-- 2) Proprietary objects containing a string which are defined in this MIB use the
-- first two bytes to hold the symbol set used to encode the string.
-- The Roman-8 symbol set has a hex encoding of 0x0115. Other
-- symbol sets are listed in the PCL 5 Comparison Guide in table
-- C-1 Symbol Set Values. Standard Printer MIB (prt...objects) and Host
-- Resources MIB (hr...objects) strings do not contain symbol set
-- information.
--
-- 3) Some of the objects included are only supported if an accessory
-- is installed. These accessories include:
-- MIO/EIO based accessories
-- SIMM/DIMM based accessories
-- Mass storage devices
-- Paper handling accessories
-- Adobe PostScript accessory
--
LaserJet5Si-Mopier-MIB DEFINITIONS ::= BEGIN
IMPORTS
enterprises FROM SNMPv2-SMI,
DisplayString FROM SNMPv2-TC;
hp OBJECT IDENTIFIER ::= { enterprises 11 }
nm OBJECT IDENTIFIER ::= { hp 2 }
hpsystem OBJECT IDENTIFIER ::= { nm 3 }
net-peripheral OBJECT IDENTIFIER ::= { hpsystem 9 }
netdm OBJECT IDENTIFIER ::= { net-peripheral 4 }
dm OBJECT IDENTIFIER ::= { netdm 2}
device OBJECT IDENTIFIER ::= { dm 1 }
system OBJECT IDENTIFIER ::= { device 1 }
settings-system OBJECT IDENTIFIER ::= { system 1 }
status-system OBJECT IDENTIFIER ::= { system 2 }
background-message OBJECT IDENTIFIER ::= { status-system 37 }
background-message1 OBJECT IDENTIFIER ::= { background-message 1 }
background-message2 OBJECT IDENTIFIER ::= { background-message 2 }
id OBJECT IDENTIFIER ::= { system 3 }
interface OBJECT IDENTIFIER ::= { system 4 }
simm OBJECT IDENTIFIER ::= { interface 1 }
simm1 OBJECT IDENTIFIER ::= { simm 1 }
simm2 OBJECT IDENTIFIER ::= { simm 2 }
simm3 OBJECT IDENTIFIER ::= { simm 3 }
simm4 OBJECT IDENTIFIER ::= { simm 4 }
mio OBJECT IDENTIFIER ::= { interface 3 }
mio1 OBJECT IDENTIFIER ::= { mio 1 }
mio2 OBJECT IDENTIFIER ::= { mio 2 }
phd OBJECT IDENTIFIER ::= { interface 5 }
phd1 OBJECT IDENTIFIER ::= { phd 1 }
phd2 OBJECT IDENTIFIER ::= { phd 2 }
phd3 OBJECT IDENTIFIER ::= { phd 3 }
phd4 OBJECT IDENTIFIER ::= { phd 4 }
phd5 OBJECT IDENTIFIER ::= { phd 5 }
phd6 OBJECT IDENTIFIER ::= { phd 6 }
test OBJECT IDENTIFIER ::= { system 5 }
job OBJECT IDENTIFIER ::= { system 6 }
settings-job OBJECT IDENTIFIER ::= { job 1 }
active-print-jobs OBJECT IDENTIFIER ::= { job 2 }
job-being-parsed OBJECT IDENTIFIER ::= { active-print-jobs 1 }
job-info OBJECT IDENTIFIER ::= { job 5 }
job-info-attribute OBJECT IDENTIFIER ::= { job-info 23 }
errorlog OBJECT IDENTIFIER ::= { system 11 }
error1 OBJECT IDENTIFIER ::= { errorlog 1 }
error2 OBJECT IDENTIFIER ::= { errorlog 2 }
error3 OBJECT IDENTIFIER ::= { errorlog 3 }
error4 OBJECT IDENTIFIER ::= { errorlog 4 }
error5 OBJECT IDENTIFIER ::= { errorlog 5 }
error6 OBJECT IDENTIFIER ::= { errorlog 6 }
error7 OBJECT IDENTIFIER ::= { errorlog 7 }
error8 OBJECT IDENTIFIER ::= { errorlog 8 }
error9 OBJECT IDENTIFIER ::= { errorlog 9 }
error10 OBJECT IDENTIFIER ::= { errorlog 10 }
error11 OBJECT IDENTIFIER ::= { errorlog 11 }
error12 OBJECT IDENTIFIER ::= { errorlog 12 }
error13 OBJECT IDENTIFIER ::= { errorlog 13 }
error14 OBJECT IDENTIFIER ::= { errorlog 14 }
error15 OBJECT IDENTIFIER ::= { errorlog 15 }
error16 OBJECT IDENTIFIER ::= { errorlog 16 }
error17 OBJECT IDENTIFIER ::= { errorlog 17 }
error18 OBJECT IDENTIFIER ::= { errorlog 18 }
error19 OBJECT IDENTIFIER ::= { errorlog 19 }
error20 OBJECT IDENTIFIER ::= { errorlog 20 }
error21 OBJECT IDENTIFIER ::= { errorlog 21 }
error22 OBJECT IDENTIFIER ::= { errorlog 22 }
error23 OBJECT IDENTIFIER ::= { errorlog 23 }
error24 OBJECT IDENTIFIER ::= { errorlog 24 }
error25 OBJECT IDENTIFIER ::= { errorlog 25 }
error26 OBJECT IDENTIFIER ::= { errorlog 26 }
error27 OBJECT IDENTIFIER ::= { errorlog 27 }
error28 OBJECT IDENTIFIER ::= { errorlog 28 }
error29 OBJECT IDENTIFIER ::= { errorlog 29 }
error30 OBJECT IDENTIFIER ::= { errorlog 30 }
error31 OBJECT IDENTIFIER ::= { errorlog 31 }
error32 OBJECT IDENTIFIER ::= { errorlog 32 }
error33 OBJECT IDENTIFIER ::= { errorlog 33 }
error34 OBJECT IDENTIFIER ::= { errorlog 34 }
error35 OBJECT IDENTIFIER ::= { errorlog 35 }
error36 OBJECT IDENTIFIER ::= { errorlog 36 }
error37 OBJECT IDENTIFIER ::= { errorlog 37 }
error38 OBJECT IDENTIFIER ::= { errorlog 38 }
error39 OBJECT IDENTIFIER ::= { errorlog 39 }
error40 OBJECT IDENTIFIER ::= { errorlog 40 }
error41 OBJECT IDENTIFIER ::= { errorlog 41 }
error42 OBJECT IDENTIFIER ::= { errorlog 42 }
error43 OBJECT IDENTIFIER ::= { errorlog 43 }
error44 OBJECT IDENTIFIER ::= { errorlog 44 }
error45 OBJECT IDENTIFIER ::= { errorlog 45 }
error46 OBJECT IDENTIFIER ::= { errorlog 46 }
error47 OBJECT IDENTIFIER ::= { errorlog 47 }
error48 OBJECT IDENTIFIER ::= { errorlog 48 }
error49 OBJECT IDENTIFIER ::= { errorlog 49 }
error50 OBJECT IDENTIFIER ::= { errorlog 50 }
source-subsystem OBJECT IDENTIFIER ::= { device 2 }
io OBJECT IDENTIFIER ::= { source-subsystem 1 }
settings-io OBJECT IDENTIFIER ::= { io 1 }
ports OBJECT IDENTIFIER ::= { io 3 }
port1 OBJECT IDENTIFIER ::= { ports 1 }
processing-subsystem OBJECT IDENTIFIER ::= { device 3 }
pdl OBJECT IDENTIFIER ::= { processing-subsystem 3 }
settings-pdl OBJECT IDENTIFIER ::= { pdl 1 }
status-pdl OBJECT IDENTIFIER ::= { pdl 2 }
pdl-pcl OBJECT IDENTIFIER ::= { pdl 3 }
pdl-postscript OBJECT IDENTIFIER ::= { pdl 4 }
pjl OBJECT IDENTIFIER ::= { processing-subsystem 5 }
destination-subsystem OBJECT IDENTIFIER ::= { device 4 }
print-engine OBJECT IDENTIFIER ::= { destination-subsystem 1 }
settings-prt-eng OBJECT IDENTIFIER ::= { print-engine 1 }
status-prt-eng OBJECT IDENTIFIER ::= { print-engine 2 }
intray OBJECT IDENTIFIER ::= { print-engine 3 }
settings-intray OBJECT IDENTIFIER ::= { intray 1 }
intrays OBJECT IDENTIFIER ::= { intray 3 }
intray4 OBJECT IDENTIFIER ::= { intrays 4 }
intray5 OBJECT IDENTIFIER ::= { intrays 5 }
outbin OBJECT IDENTIFIER ::= { print-engine 4 }
settings-outbin OBJECT IDENTIFIER ::= { outbin 1 }
outbins OBJECT IDENTIFIER ::= { outbin 3 }
outbin1 OBJECT IDENTIFIER ::= { outbins 1 }
outbin3 OBJECT IDENTIFIER ::= { outbins 3 }
outbin4 OBJECT IDENTIFIER ::= { outbins 4 }
outbin5 OBJECT IDENTIFIER ::= { outbins 5 }
outbin6 OBJECT IDENTIFIER ::= { outbins 6 }
outbin7 OBJECT IDENTIFIER ::= { outbins 7 }
outbin8 OBJECT IDENTIFIER ::= { outbins 8 }
outbin9 OBJECT IDENTIFIER ::= { outbins 9 }
outbin10 OBJECT IDENTIFIER ::= { outbins 10 }
outbin11 OBJECT IDENTIFIER ::= { outbins 11 }
marking-agent OBJECT IDENTIFIER ::= { print-engine 5 }
settings-marking-agent OBJECT IDENTIFIER ::= { marking-agent 1 }
imaging OBJECT IDENTIFIER ::= { print-engine 6 }
ph OBJECT IDENTIFIER ::= { print-engine 7 }
ph-devices OBJECT IDENTIFIER ::= { ph 3 }
ph2 OBJECT IDENTIFIER ::= { ph-devices 2 }
ph3 OBJECT IDENTIFIER ::= { ph-devices 3 }
ph4 OBJECT IDENTIFIER ::= { ph-devices 4 }
print-media OBJECT IDENTIFIER ::= { print-engine 8 }
settings-print-media OBJECT IDENTIFIER ::= { print-media 1 }
media-info OBJECT IDENTIFIER ::= { print-media 3 }
media1 OBJECT IDENTIFIER ::= { media-info 1 }
media2 OBJECT IDENTIFIER ::= { media-info 2 }
media3 OBJECT IDENTIFIER ::= { media-info 3 }
media4 OBJECT IDENTIFIER ::= { media-info 4 }
media5 OBJECT IDENTIFIER ::= { media-info 5 }
media6 OBJECT IDENTIFIER ::= { media-info 6 }
media7 OBJECT IDENTIFIER ::= { media-info 7 }
media8 OBJECT IDENTIFIER ::= { media-info 8 }
media9 OBJECT IDENTIFIER ::= { media-info 9 }
media10 OBJECT IDENTIFIER ::= { media-info 10 }
media11 OBJECT IDENTIFIER ::= { media-info 11 }
media12 OBJECT IDENTIFIER ::= { media-info 12 }
media13 OBJECT IDENTIFIER ::= { media-info 13 }
media14 OBJECT IDENTIFIER ::= { media-info 14 }
media15 OBJECT IDENTIFIER ::= { media-info 15 }
tables OBJECT IDENTIFIER ::= { device 7 }
channel-table OBJECT IDENTIFIER ::= { tables 2 }
channel-entry OBJECT IDENTIFIER ::= { channel-table 1 }
file-system OBJECT IDENTIFIER ::= { system 10 }
settings-file-system OBJECT IDENTIFIER ::= { file-system 1 }
status-file-system OBJECT IDENTIFIER ::= { file-system 2 }
file-systems OBJECT IDENTIFIER ::= { file-system 3 }
file-system2 OBJECT IDENTIFIER ::= { file-systems 2 }
resource-manager OBJECT IDENTIFIER ::= { system 12 }
mass-storage-resources OBJECT IDENTIFIER ::= { resource-manager 3 }
remote-procedure-call OBJECT IDENTIFIER ::= { system 13 }
settings-rpc OBJECT IDENTIFIER ::= { remote-procedure-call 1 }
status-rpc OBJECT IDENTIFIER ::= { remote-procedure-call 2 }
rpc-services OBJECT IDENTIFIER ::= { remote-procedure-call 3 }
mount OBJECT IDENTIFIER ::= { rpc-services 1 }
settings-mount OBJECT IDENTIFIER ::= { mount 1 }
nfs-server OBJECT IDENTIFIER ::= { rpc-services 2 }
settings-nfs-server OBJECT IDENTIFIER ::= { nfs-server 1 }
status-nfs-server OBJECT IDENTIFIER ::= { nfs-server 2 }
rpc-bind OBJECT IDENTIFIER ::= { rpc-services 3 }
settings-rpc-bind OBJECT IDENTIFIER ::= { rpc-bind 1 }
status-rpc-bind OBJECT IDENTIFIER ::= { rpc-bind 2 }
xport-interface OBJECT IDENTIFIER ::= { system 14 }
status-xip OBJECT IDENTIFIER ::= { xport-interface 2 }
mass-storage-block-driver OBJECT IDENTIFIER ::= { system 15 }
mass-storage-block-drivers OBJECT IDENTIFIER ::= { mass-storage-block-driver 3 }
mass-storage-bd2 OBJECT IDENTIFIER ::= { mass-storage-block-drivers 2 }
settings-msbd2 OBJECT IDENTIFIER ::= { mass-storage-bd2 1 }
hrm OBJECT IDENTIFIER ::= { dm 3 }
hrStorage OBJECT IDENTIFIER ::= { hrm 2 }
hrStorageTable OBJECT IDENTIFIER ::= { hrStorage 3 }
hrStorageEntry OBJECT IDENTIFIER ::= { hrStorageTable 1 }
hrDevice OBJECT IDENTIFIER ::= { hrm 3 }
hrDeviceTable OBJECT IDENTIFIER ::= { hrDevice 2 }
hrDeviceEntry OBJECT IDENTIFIER ::= { hrDeviceTable 1 }
hrPrinterTable OBJECT IDENTIFIER ::= { hrDevice 5 }
hrPrinterEntry OBJECT IDENTIFIER ::= { hrPrinterTable 1 }
printmib OBJECT IDENTIFIER ::= { dm 2 }
prtGeneral OBJECT IDENTIFIER ::= { printmib 5 }
prtGeneralTable OBJECT IDENTIFIER ::= { prtGeneral 1 }
prtGeneralEntry OBJECT IDENTIFIER ::= { prtGeneralTable 1 }
prtCover OBJECT IDENTIFIER ::= { printmib 6 }
prtCoverTable OBJECT IDENTIFIER ::= { prtCover 1 }
prtCoverEntry OBJECT IDENTIFIER ::= { prtCoverTable 1 }
prtLocalization OBJECT IDENTIFIER ::= { printmib 7 }
prtLocalizationTable OBJECT IDENTIFIER ::= { prtLocalization 1 }
prtLocalizationEntry OBJECT IDENTIFIER ::= { prtLocalizationTable 1 }
prtStorageRefTable OBJECT IDENTIFIER ::= { prtGeneral 2 }
prtStorageRefEntry OBJECT IDENTIFIER ::= { prtStorageRefTable 1 }
prtDeviceRefTable OBJECT IDENTIFIER ::= { prtGeneral 3 }
prtDeviceRefEntry OBJECT IDENTIFIER ::= { prtDeviceRefTable 1 }
prtInput OBJECT IDENTIFIER ::= { printmib 8 }
prtInputTable OBJECT IDENTIFIER ::= { prtInput 2 }
prtInputEntry OBJECT IDENTIFIER ::= { prtInputTable 1 }
prtOutput OBJECT IDENTIFIER ::= { printmib 9 }
prtOutputTable OBJECT IDENTIFIER ::= { prtOutput 2 }
prtOutputEntry OBJECT IDENTIFIER ::= { prtOutputTable 1 }
prtMarker OBJECT IDENTIFIER ::= { printmib 10 }
prtMarkerTable OBJECT IDENTIFIER ::= { prtMarker 2 }
prtMarkerEntry OBJECT IDENTIFIER ::= { prtMarkerTable 1 }
prtMarkerSupplies OBJECT IDENTIFIER ::= { printmib 11 }
prtMarkerSuppliesTable OBJECT IDENTIFIER ::= { prtMarkerSupplies 1 }
prtMarkerSuppliesEntry OBJECT IDENTIFIER ::= { prtMarkerSuppliesTable 1 }
prtMediaPath OBJECT IDENTIFIER ::= { printmib 13 }
prtMediaPathTable OBJECT IDENTIFIER ::= { prtMediaPath 4 }
prtMediaPathEntry OBJECT IDENTIFIER ::= { prtMediaPathTable 1 }
prtChannel OBJECT IDENTIFIER ::= { printmib 14 }
prtChannelTable OBJECT IDENTIFIER ::= { prtChannel 1 }
prtChannelEntry OBJECT IDENTIFIER ::= { prtChannelTable 1 }
prtInterpreter OBJECT IDENTIFIER ::= { printmib 15 }
prtInterpreterTable OBJECT IDENTIFIER ::= { prtInterpreter 1 }
prtInterpreterEntry OBJECT IDENTIFIER ::= { prtInterpreterTable 1 }
prtConsoleDisplayBuffer OBJECT IDENTIFIER ::= { printmib 16 }
prtConsoleDisplayBufferTable OBJECT IDENTIFIER ::= { prtConsoleDisplayBuffer 5 }
prtConsoleDisplayBufferEntry OBJECT IDENTIFIER ::= { prtConsoleDisplayBufferTable 1 }
prtConsoleLights OBJECT IDENTIFIER ::= { printmib 17 }
prtConsoleLightTable OBJECT IDENTIFIER ::= { prtConsoleLights 6 }
prtConsoleLightEntry OBJECT IDENTIFIER ::= { prtConsoleLightTable 1 }
prtAlert OBJECT IDENTIFIER ::= { printmib 18 }
prtAlertTable OBJECT IDENTIFIER ::= { prtAlert 1 }
prtAlertEntry OBJECT IDENTIFIER ::= { prtAlertTable 1 }
energy-star OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS optional
DESCRIPTION
"Returns or changes the Energy Star sleep value. If the
value is greater than zero, then the device will go into
energy saving sleep mode after the print engine has been
idle for the number of seconds specified by this object.
A value of zero means Energy Star is disabled and the
device will not go to sleep based on print engine idle
time. The value must be non-negative.
Additional information:
Returns or changes the Energy Star sleep value.
The device will go into energy saving sleep
mode after the print engine has been idle for
the number of seconds specified by this
object. LaserJet 5Si supports values of 0, 900, 1800,
3600, 7200, and 10800; additionally, a value of 10 is
supported in Service Mode. A value of 0 means
never go to sleep based on print engine idle
time. Setting to an unsupported value causes
the printer to substitute a value (listed
below) and to return <noError>
status.
The values for normal operation are as follow:
<=0 snap to 0
>= 1 and <= 1349 snap to 900 (15 minutes)
>= 1350 and <= 2699 snap to 1800 (30 minutes)
>= 2700 and <= 5399 snap to 3600 (60 minutes)
>= 5400 and <= 8999 snap to 7200 (120 minutes)
>= 9000 snap to 10800 (180 minutes)
The values for Service Mode operation are the same as
above except 10 is a legal value (no snapping). When
the printer exits Service Mode the default value is
restored."
::= { settings-system 1 }
sleep-mode OBJECT-TYPE
SYNTAX INTEGER {
eFalse(1),
eTrue(2)
}
ACCESS read-write
STATUS optional
DESCRIPTION
"Returns eTrue if the device is in energy saving sleep
mode, otherwise returns eFalse. Setting SLEEP-MODE to
eFalse causes the device to wake up, if it is in sleep
mode. Setting SLEEP-MODE to eTrue causes the device to
go into sleep mode.
Additional information:
Setting to this object to eTrue while printer is
awake will not change the
printer's current state and will return
<genErr> status.
Setting to this object to eTrue while printer is
already in the Sleep Mode will not change the
printer's current state and will return <noError> status.
Setting to eFalse while printer is already awake
will not change the printer's
current state and will return <noError> status."
::= { settings-system 2 }
on-off-line OBJECT-TYPE
SYNTAX INTEGER {
eOnline(1),
eOffline(2),
eOfflineAtEndOfJob(3)
}
ACCESS read-write
STATUS optional
DESCRIPTION
"To bring the PDL processing sub-system on or off line.
If the device is a printer, then the printer does not
process print job data when the printer is off line.
PML communication persists.
Additional information:
When the printer is in the Offline state,
printing will stop as soon as possible (no more sheets
of media are pulled from input trays). All I/O
communication continues (no change from the Online
state).
Setting to eOnline has the following affect:
Printer will immediately go to or remain in the Online
state; <noError> status is returned.
If the printer's current state
is Offline with a pending error condition that
prevents the printer from going to the Online
state, the printer will remain in the Offline state;
<genErr> status is returned.
Setting to eOffline has the following affect:
Printer will immediately go to or remain in the
Offline state; <noError> status is returned.
If pages are being printed, those pages will complete
with the printer in the Offline state.
Setting to eOfflineAtEndOfJob has the following
affect:
If not in a job or already in the Offline state, the
printer will immediately go to or remain in the
Offline state; <noError> status is returned.
If in a job and the current state is Online, the
printer will remain in the Online state, with the
value of this object as eOfflineAtEndOfJob, until the
end of the job; <noError> status is returned. At the end of
the job, the printer goes to the Offline state and the
value of this object becomes eOffline.
Setting this object to eOffline or eOnline before the
end of the job causes the action for that value to be
taken immediately."
::= { status-system 5 }
continue OBJECT-TYPE
SYNTAX INTEGER {
eInitiateAction(1)
}
ACCESS write-only
STATUS optional
DESCRIPTION
"A device can support a class of errors called
continuable errors. When a continuable error is
encountered, the device requires a continue event to
occur before the device will continue operation. One
continue event is setting the CONTINUE object to
eInitiateAction. Devices can support other continue
events, like auto-continue. A continue event causes the
continuable error to be acknowledged, thus allowing the
device to continue. Each device needs to list the
continuable errors. If the device doesn't currently
have an unacknowledged continuable error, the response
will contain <genErr>.
Additional information:
If LaserJet 5Si doesn't currently
have an unacknowledged continuable error, the
response will contain <noError> status.
Since LaserJet 5Si does not have a CONTINUE key, the SELECT key is used to perform
the continue operation at the control panel. "
::= { status-system 6 }
auto-continue OBJECT-TYPE
SYNTAX INTEGER {
eOff(1),
eOn(2)
}
ACCESS read-write
STATUS optional
DESCRIPTION
"Indicates if the device will automatically continue
after encountering a continuable error. If AUTO-
CONTINUE is set to eOn, the device will automatically
generate continue event to acknowledge continuable
errors. If AUTO-CONTINUE is set to eOff, then some
other continue event will have to acknowledge the
continuable error."
::= { status-system 7 }
job-input-auto-continue-timeout OBJECT-TYPE
SYNTAX INTEGER(-1..3600)
ACCESS read-write
STATUS optional
DESCRIPTION
"The number of seconds the device waits after a job
related continuable error occurs before automatically
continuing. An example job related continuable error is
the job requesting a media size that is not available.
After the timeout expires, the device will continue
processing the job as if a continue event occurred, such
as the front panel continue key being pressed. If the
value is -1, the device does not automatically continue
after a job related continuable error occurs. If the
value is 0, the device immediately continues. If the
value is greater than 0, the value represents the
timeout value in seconds.
Additional information:
This object is used only for media requests
(size and/or name).
LaserJet 5Si supports any value in the range of -1 to 3600. Setting to a value
outside of that range causes
the printer to substitute a value (listed
below) and to return <noError>
status.
The values are as follow:
<-1 snaps to -1
>3600 snaps to 3600 (60 minutes)
The action that occurs when this timeout expires is explained by
JOB-INPUT-AUTO-CONTINUE-MODE. It is not the same as the CONTINUE
object being set to eInitiateAction or the Select key being pressed on
the control panel. "
::= { status-system 35 }
job-input-auto-continue-mode OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS optional
DESCRIPTION
"Returns or sets the device behavior when the desired
media is not currently available.
cCancelJob - The device cancels the job. The device
POS should explain what happens if this item is not the
only item in the collection.
cAutoMediaSizeOverride - The device is allowed to
substitute a different size media.
cAutoMediaNameOverride - The device is allowed to
substitute a different media name.
Additional information:
If cCancelJob is set, the current print job will
be canceled regardless of other item settings. At least one bit of the
collection must be set; setting this object to zero will cause a status of
<badValue> to be returned.
This object applies to all media requests, including Manual Feed Requests.
This object describes the action that is performed when the
JOB-INPUT-AUTO-CONTINUE-TIMEOUT expires. The action performed by the CONTINUE
object being set to eInitiateAction or the Select key being pressed on
the control panel may cause different actions. "
::= { status-system 36 }
background-status-msg-line1-part1 OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-write
STATUS optional
DESCRIPTION
"The string displayed on the device's front panel in
place of the printer's built-in background status
string. An example built-in background status string is
'00 READY'.
Additional information:
This object allows a message to be displayed when
it is the highest priority message. Setting this
objedct does not guarantee the message will be
displayed; and reading it returns the value last
written, not the currently displayed message (use
prtConsoleDisplayBufferText to read the
display).
The priority assigned for displaying this message
is one lower than the PJL RDYMSG.
To clear the message, write a null string to this
object.
While the object prtConsoleLocalization controls the
localization and symbol set usage of printer generated messages, this
object's message is displayed using the symbol set
specified with the string. The default symbol set is Roman-8; additional
legal symbol sets are ISOLatin5, ISOLatin2 and Windows31J.
When either BACKGROUND-STATUS-MSG-LINE1-PART1 or
BACKGROUND-STATUS-MSG-LINE2-PART1 contains a non-null value, both will be
displayed."
::= { background-message1 1 }
background-status-msg-line2-part1 OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-write
STATUS optional
DESCRIPTION
"The string displayed on the device's front panel in
place of the printer's built-in background status
string. An example built-in background status string is
'00 READY'.
Additional information:
See BACKGROUND-STATUS-MSG-LINE1-PART1"
::= { background-message2 1 }
error-log-clear OBJECT-TYPE
SYNTAX INTEGER {
eClearErrorLog(1)
}
ACCESS write-only
STATUS optional
DESCRIPTION
"Setting this object clears all the entries in the error
log sub-tree."
::= { status-system 38 }
job-output-auto-continue-timeout OBJECT-TYPE
SYNTAX INTEGER(-1..3600)
ACCESS read-write
STATUS optional
DESCRIPTION
"Returns or sets the time that the printer will wait
after an output bin becomes full and the printer is
trying to deliver a sheet of media to that output bin.
When the timeout expires, the job is processed according
to the OUTBINn-OVERRIDE-MODE. A value of -1 indicates
that the printer will wait for a continue event. A non-
negative value is the number of seconds to wait.
Additional information:
A value of zero means to continue immediately."
::= { status-system 40 }
model-number OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS optional
DESCRIPTION
"Identifies the device model number as listed in the HP
corporate price list (e.g. C2121A for DeskJet 500C).
The string is as specific as possible. Products should
note in POS if the model number on the CPL changes but
the device reports the previous model number. If the
model number changes based on the installed options, the
POS should indicate if only the base model number is
returned, or if the device senses the installed options
and returns the correct model number. If possible,
encode the model number in a symbol set (like Roman-8)
that matches the ASCII character set and limit the
characters used to ASCII characters.
Additional information:
The value of this object does not change based on
the installed options."
::= { id 1 }
model-name OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS optional
DESCRIPTION
"Identifies the device model name (e.g. ''DeskJet
1200C''). The string is as specific as possible.
Capitalization and spacing should match family naming
conventions. Products should note in POS if the model
name on the HP corporate price list changes but the
device reports the previous device name. If the model
name changes based on the installed options, the POS
should indicate if only the base model name is returned,
or if the device senses the installed options and
returns the correct model name. If possible, encode the
model name in a symbol set (like Roman-8) that matches
the ASCII character set and limit the characters used to
ASCII characters.
Additional information:
The value of this object does not change based on
the installed options.
Since the value of this object is frequently used in displaying a list of
printers, it is kept relatively short in case systems have limited width
for their display area."
::= { id 2 }
serial-number OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS optional
DESCRIPTION
"Identifies the serial number for the device. If the
SERIAL-NUMBER object is set by the user, then setting
the object does not need to be protected. If the
SERIAL-NUMBER object is set at the factory, then the
SERVICE-PASSWORD object must be set correctly before the
SERIAL-NUMBER object is writable. If this is a writable
object, the POS should indicate the maximum supported
string length. If possible, encode the serial number in
a symbol set (like Roman-8) that matches the ASCII
character set and limit the characters used to ASCII
characters.
Additional information:
The format of the LaserJet 5Si serial number is:
aaxxyynnnn
where: aa=A-Z, xx=A..Z & 0..9, yy=0..9 & A..Z, nn=0..9
This object is read-only so the SERVICE-PASSWORD object is not used."
::= { id 3 }
device-name OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-write
STATUS optional
DESCRIPTION
"User defined device name. The POS should indicate the
maximum supported string length. If the user entered
string is too long, the device will store as much as
possible and will return the <noError>.
Additional information:
This object is stored in NVRAM.
The maximum supported string length is 32
characters. If the user entered string is too long,
the device will store the first 32 characters and will
return the <noError> status."
::= { id 10 }
device-location OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-write
STATUS optional
DESCRIPTION
"User defined device location. The POS should indicate
the maximum supported string length. If the user
entered string is too long, the device will store as
much as possible and will return the <noError>.
Additional information:
The maximum supported string length is 16
characters. If the user entered string is too long,
the device will store the first 16 characters and will
return the <noError> status.
This object is saved in NVRAM."
::= { id 11 }
asset-number OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-write
STATUS optional
DESCRIPTION
"User defined asset number. The POS should indicate the
maximum supported string length. If the user entered
string is too long, the device will store as much as
possible and will return the <noError>.
Additional information:
The maximum supported string length is 8
characters. If the user entered string is too long,
the device will store the first 8 characters and will
return the <noError> status.
This object is saved in NVRAM."
::= { id 12 }
simm1-type OBJECT-TYPE
SYNTAX INTEGER {
eEmpty(1),
eUnknown(2),
eUnSupported(3),
eReadOnlyMemory(4),
eVolatileRandomAccessMemory(5)
}
ACCESS read-only
STATUS optional
DESCRIPTION
"Returns an indication of the type of option installed in
SIMM slot 1.
eEmpty means the device did not detect any option
installed in the interface slot.
eUnknown means the device doesn't recognize the
installed option.
eUnSupported means the device recognizes the installed
option, but does not support the option.
eReadOnlyMemory means the installed option contains
ROM Ics.
eVolatileRandomAccessMemory means the installed option
contains RAM ICs that loose data when the power is
turned off.
eNonVolatileRandomAccessMemory means that the
installed option contains RAM ICs that do not loose data
when the power is turned off.
eFlashMemory means that the installed option contains
a type of non-volatile RAM that needs to be erased
before it can be written.
eDiskDrive means the installed option contains a disk
drive. eRamRom means the installed option contains both
volatile random access memory and read only memory.
eInputPHD means the installed option is an input paper
handling device.
eOutputPHD means the installed option is an output
paper handling device.
eIOCard means the installed option is an I/O card."
::= { simm1 4 }
simm1-capacity OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION
"Returns an indication of the capacity of the SIMM
installed in SIMM slot 1. The capacity is dependent on
the type of option, as indicated by the SIMM1-TYPE
object. This object has no meaning if the installed
option type is eUnknown or eReadOnlyMemory. This object
contains the size, in bytes, if the installed option
type is eVolatileRandomAccessMemory,
eNonVolatileRandomAccessMemory, eFlashMemory, or
eDiskDrive. If the type of the installed option is
eRamRom, this object contains the size, in bytes, of the
random access memory. If the type of the installed
option is eInputPHD, the capacity indicates the number
of input trays supported by the installed option. If
the type of the installed option is eOutputPHD, the
capacity indicates the number of output bins supported
by the installed option. If the type of the installed
option is eIOCard, the capacity indicates the number of
logical I/O ports supported by the I/O card.
Additional information:
Returns an indication of the capacity of the
installed option in bytes. This object is not
supported unless the SIMM1-TYPE type is
eVolatileRandomAccessMemory."
::= { simm1 5 }
simm2-type OBJECT-TYPE
SYNTAX INTEGER {
eEmpty(1),
eUnknown(2),
eUnSupported(3),
eReadOnlyMemory(4),
eVolatileRandomAccessMemory(5)
}
ACCESS read-only
STATUS optional
DESCRIPTION
"Returns an indication of the type of option installed in
SIMM slot 2. See SIMM1-TYPE for a description."
::= { simm2 4 }
simm2-capacity OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION
"Returns an indication of the capacity of the SIMM
installed in SIMM slot 2. See SIMM1-CAPACITY for a
description.
Additional information:
Returns an indication of the capacity of the
installed option in bytes. This object is not
supported unless the SIMM2-TYPE type is
eVolatileRandomAccessMemory."
::= { simm2 5 }
simm3-type OBJECT-TYPE
SYNTAX INTEGER {
eEmpty(1),
eUnknown(2),
eUnSupported(3),
eReadOnlyMemory(4),
eVolatileRandomAccessMemory(5)
}
ACCESS read-only
STATUS optional
DESCRIPTION
"Returns an indication of the type of option installed in
SIMM slot 3. See SIMM1-TYPE for a description."
::= { simm3 4 }
simm3-capacity OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION
"Returns an indication of the capacity of the SIMM
installed in SIMM slot 3. See SIMM1-CAPACITY for a
description.
Additional information:
Returns an indication of the capacity of the
installed option in bytes. This object is not
supported unless the SIMM3-TYPE type is
eVolatileRandomAccessMemory."
::= { simm3 5 }
simm4-type OBJECT-TYPE
SYNTAX INTEGER {
eEmpty(1),
eUnknown(2),
eUnSupported(3),
eReadOnlyMemory(4),
eVolatileRandomAccessMemory(5)
}
ACCESS read-only
STATUS optional
DESCRIPTION
"Returns an indication of the type of option installed in
SIMM slot 4. See SIMM1-TYPE for a description."
::= { simm4 4 }
simm4-capacity OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION
"Returns an indication of the capacity of the SIMM
installed in SIMM slot 4. See SIMM1-CAPACITY for a
description.
Additional information:
Returns an indication of the capacity of the
installed option in bytes. This object is not
supported unless the SIMM4-TYPE type is
eVolatileRandomAccessMemory."
::= { simm4 5 }
mio1-manufacturing-info OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS optional
DESCRIPTION
"Returns information describing the manufacture of the
I/O card installed in MIO interface 1. May include
serial number and firmware revision.
Additional information:
The format of the string returned is determined by
the manufacturer of the MIO card. There is no standard for content of the
string. If no card is installed, a null string is returned."
::= { mio1 3 }
mio1-type OBJECT-TYPE
SYNTAX INTEGER {
eEmpty(1),
eIOCard(12)
}
ACCESS read-only
STATUS optional
DESCRIPTION
"Returns an indication of the type of option installed in
MIO interface 1. See SIMM1-TYPE for an explanation of
the enumerations."
::= { mio1 4 }
mio2-manufacturing-info OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS optional
DESCRIPTION
"Returns information describing the manufacture of the
I/O card installed in MIO interface 2. May include
serial number and firmware revision.
Additional information:
The format of the string returned is determined by
the manufacturer of the MIO card. There is no standard for content of the
string. If no card is installed, a null string is returned."
::= { mio2 3 }
mio2-type OBJECT-TYPE
SYNTAX INTEGER {
eEmpty(1),
eIOCard(12)
}
ACCESS read-only
STATUS optional
DESCRIPTION
"Returns an indication of the type of option installed in
MIO interface 2. See SIMM1-TYPE for an explanation of
the enumerations."
::= { mio2 4 }
phd1-model OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS optional
DESCRIPTION
"Returns product information identifying the PHD device.
Example: XXXX"
::= { phd1 1 }
phd1-manufacturing-info OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS optional
DESCRIPTION
"Returns information describing the manufacture of this
particular PHD. May include serial number and firmware
revision."
::= { phd1 2 }
phd1-type OBJECT-TYPE
SYNTAX INTEGER {
eEmpty(1),
eInputPHD(10)
}
ACCESS read-only
STATUS optional
DESCRIPTION
"Returns an indication of the type of option installed in
this particular SIMM interface See SIMM1-TYPE for an
explanation of the enumerations.
Additional information:
Returns an indication of whether or not the high
capacity envelope feeder is installed on the printer. A value of eEmpty means
that the envelope feeder is not installed."
::= { phd1 3 }
phd1-capacity OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION
"Returns an indication of the capacity of the installed
option. See SIMM1-CAPACITY for an explanation of the
meaning of the value of this object.
Additional information:
The LaserJet 5Si high capacity envelope feeder has a
single tray."
::= { phd1 4 }
phd2-model OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS optional
DESCRIPTION
"Returns product information identifying PHD device 2.
Example: XXXX"
::= { phd2 1 }
phd2-manufacturing-info OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS optional
DESCRIPTION
"Returns information describing the manufacture of PHD 2.
May include serial number and firmware revision."
::= { phd2 2 }
phd2-type OBJECT-TYPE
SYNTAX INTEGER {
eEmpty(1),
eInputPHD(10),
eOutputPHD(11)
}
ACCESS read-only
STATUS optional
DESCRIPTION
"Returns an indication of the type of option installed in
PHD interface 2. See SIMM1-TYPE for an explanation of
the enumerations.
Additional information:
External paper handling devices are connected to
the printer in a daisy-chained fashion. PHD2 refers to the first device that
is connected. Returns eEmpty if no paper handling devices are
installed.
If the HCI is attached, the value will be eInputPHD. If the HCO is the first
connected device, the value will be
eOutputPHD."
::= { phd2 3 }
phd2-capacity OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION
"Returns an indication of the capacity of the installed
option. See SIMM1-CAPACITY for an explanation of the
meaning of the value of this object.
Additional information:
The LaserJet 5Si high capacity input device has a
single tray."
::= { phd2 4 }
phd3-model OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS optional
DESCRIPTION
"Returns product information identifying PHD device 3.
Additional information:
The value returned by Tlatoani depends on the current
mode of the device. The possible values are as follows:
MULTIBIN MAILBOX C3764A [BNPxxxx.x]
MULTIBIN STACKER C3764A [BNPxxxx.x]
MULTIBIN SEPARATOR C3764A[BNPxxxx.x]."
::= { phd3 1 }
phd3-manufacturing-info OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS optional
DESCRIPTION
"Returns information describing the manufacture of PHD 3.
May include serial number and firmware revision."
::= { phd3 2 }
phd3-type OBJECT-TYPE
SYNTAX INTEGER {
eEmpty(1),
eInputPHD(10),
eOutputPHD(11)
}
ACCESS read-only
STATUS optional
DESCRIPTION
"Returns an indication of the type of option installed in
PHD interface 3. See SIMM1-TYPE for an explanation of
the enumerations.
Additional information:
External paper handling devices are connected to
the printer in a daisy-chained fashion. PHD3 refers to the second device that
is connected. Returns eEmpty if only one paper handling device
is installed.
If the HCO is attached (second on the chain), the value will be eOutputPHD.
If the HCI is the second connected device, the
value will be eInputPHD."
::= { phd3 3 }
phd3-capacity OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION
"Returns an indication of the capacity of the installed
option. See SIMM1-CAPACITY for an explanation of the
meaning of the value of this object.
Additional information:
This is the number of logical bins provided by the device."
::= { phd3 4 }
phd4-model OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS optional
DESCRIPTION
"Returns product information identifying PHD device 4.
Additional information:
Returns product information identifying the PHD4 device.
Example: OUTBIN STAPLER CXXXXA."
::= { phd4 1 }
phd4-manufacturing-info OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS optional
DESCRIPTION
"Returns information describing the manufacture of PHD 4.
May include serial number and firmware revision.
Additional information:
Returns information describing the manufacturer of PHD 4.
May include serial number and firmware revision."
::= { phd4 2 }
phd4-type OBJECT-TYPE
SYNTAX INTEGER {
eEmpty(1),
eInputPHD(10),
eOutputPHD(11),
eBindingPHD(13)
}
ACCESS read-only
STATUS optional
DESCRIPTION
"Returns an indication of the type of option installed in
PHD interface 4. See SIMM1-TYPE for an explanation of
the enumerations.
Additional information:
The envelope feeder is PHD1. The remaining
external paper handling devices are connected to
the printer in a daisy-chained fashion. PHD4
refers to the third device that is connected.
Returns the type of the 3 rd party device in this
chain, otherwise, eEmpty if only two paper
handling devices are installed."
::= { phd4 3 }
phd4-capacity OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION
"Returns an indication of the capacity of the installed
option. See SIMM1-CAPACITY for an explanation of the
meaning of the value of this object.
Additional information:
Returns an indication of the capacity of the installed
option. See SIMM1-CAPACITY for an explanation of the
meaning of the value of this object."
::= { phd4 4 }
phd5-type OBJECT-TYPE
SYNTAX INTEGER {
eEmpty(1),
eInputPHD(10),
eOutputPHD(11)
}
ACCESS read-only
STATUS optional
DESCRIPTION
"Returns an indication of the type of option installed in
PHD interface 5. See SIMM1-TYPE for an explanation of
the enumerations.
Additional information:
External paper handling devices are connected to
the printer in a daisy-chained fashion. PHD5 refers to the fourth device that
is connected. Returns eEmpty if only three paper handling devices
are installed.
At introduction, there is no planned configuration that would cause the value
of this object to be anything other than eEmpty."
::= { phd5 3 }
phd6-type OBJECT-TYPE
SYNTAX INTEGER {
eEmpty(1),
eInputPHD(10),
eOutputPHD(11)
}
ACCESS read-only
STATUS optional
DESCRIPTION
"Returns an indication of the type of option installed in
PHD interface 6. See SIMM1-TYPE for an explanation of
the enumerations.
Additional information:
External paper handling devices are connected to
the printer in a daisy-chained fashion. PHD6 refers to the fifth device that
is connected. Returns eEmpty if only three paper handling devices
are installed.
At introduction, there is no planned configuration that would cause the value
of this object to be anything other than eEmpty."
::= { phd6 3 }
self-test OBJECT-TYPE
SYNTAX INTEGER {
eNotInASelfTest(1),
eNonDestructiveSelfTest(4)
}
ACCESS read-write
STATUS optional
DESCRIPTION
"Writing this object allows a device self test to be
started. Reading this object provides an indication
what self-test is currently executing, if any. Actual
self-test operation is device specific. A self test may
not be allowed at any arbitrary time. If the device
supports the requested self test, but can not start the
execution of the self test when requested, the device
will respond with <genErr>.
If a non-destructive self test is being started, the device
will generate a response before the self test is
completed.
RECOMMENDATION: If the device is ready (i.e. the NOT-
READY-PRINTER object does not contain any items, except
maybe being off-line) and is idle (i.e. the NOT-IDLE
object does not contain any items), this request should
always succeed. This provides a mechanism for driver
writers to always determine if the action will succeed
or not.
Additional information:
The eNonDestructiveSelfTest performs limited
testing on the printer and its attached paper handling
devices. After the self-test is complete a
configuration page is printed. The recommended
way to cause a configuration page to be printed is to
use the PRINT-INTERNAL-PAGE object.
A continuous self test cannot be started
or terminated using this OID.
The printer must be idle before it can execute a
self test. The best method to assure that the
printer is idle is to set the object ON-OFF-LINE to
eOfflineAtEndOfJob, wait for the printer to be
offline and then execute the self test. The printer
will put itself online to print the page.
When the printer is idle, setting this object to
eNonDestructiveSelfTest results in a status of <noError>
and a value of eNonDestructiveSelfTest being returned.
If the printer is not idle (whether printing an
external job, printing an internal page or running
self test), a status of
<genErr> status will be
returned with a value of eNotInASelfTest.
When the printer is idle, setting this object to
eNonDestructiveSelfTestcauses some internal testing,
the page to be formatted and put in the printer's
print queue. Before the page is in the print queue, a
get on this object will return eNonDestructiveSelfTest
(it is currently estimated that the time to format the
page is one millisecond).
Attempting to set this object before the page has
completed being formatted and printed will cause
<genErr> status to be
returned with a value of eNotInASelfTest.
After the page is in the queue, a get on this object
will return a value of eNotInASelfTest.
Setting this object to eNonDestructiveSelfTest
before the first page has completed results in
a status of <genErr> status
with a value of eNotInASelfTest.
Likewise, if the PRINT-INTERNAL-PAGE object is set to
a valid value and that page has not printed
when this object is set to eNonDestructiveSelfTest, a
status of <genErr> status
with a value of eNotInASelfTest will be
returned until the internal page has printed."
::= { test 1 }
print-internal-page OBJECT-TYPE
SYNTAX INTEGER {
eNotPrintingAnInternalPage(1),
ePrintingAnUnknownInternalPage(2),
eDeviceDemoPage2(4),
eDeviceDemoPage5ErrorLog(7),
eDeviceDemoPage6FileSystemDirectoryListing(8),
ePCLDemoPage1ConfigurationPage(300),
ePCLFontList1(350),
ePostScriptDemoPage1ConfigurationPage(400),
ePostScriptFontList1(450)
}
ACCESS read-write
STATUS optional
DESCRIPTION
"Writing this object to a value other than
eNotPrintingAnInternalPage causes the device to attempt
to print an internally generated page. Reading this
object provides an indication what internally generated
page is currently being printed, if any. The actual
page is device specific. Some devices may support
continuously printing an internally generated page.
Setting this object to eNotPrintingAnInternalPage
terminates continuously printing internally generated
pages. An internally generated page may not be allowed
to be printed at any arbitrary time; under what
conditions it will succeed or fail is device specific.
If the device supports the requested page, but can not
start printing the page when requested, the device will
respond with <genErr>.
RECOMMENDATION: If the device is ready (i.e. the NOT-
READY-PRINTER object does not contain any items, except
maybe being off-line) and is idle (i.e. the NOT-IDLE
object does not contain any items), this request should
always succeed. This provides a mechanism for driver
writers to always determine if the action will succeed
or not.
Additional information:
eDeviceDemoPage2 is the printer demo page.
ePCLFontList1 is the PCL typeface list.
eDeviceDemoPage5ErrorLog is the printer's error log.
LaserJet 5Si does not support continuously printing a demo
page.
The value eDeviceDemoPage6FileSystemDirectoryListing
can only be set when the disk option is installed;
values ePostScriptDemoPage1ConfigurationPage and
ePostScriptFontList1 can be set only when PostScript
is installed. Attempting to set these values without
the proper option installed will result in a status of
<badValue> being returned.
The printer must be idle before it will print an
internal page. The best method to assure that the
printer is idle is to set the object ON-OFF-LINE to
eOfflineAtEndOfJob, wait for the printer to be
offline and then print the internal page. The printer
will put itself online to print the page.
When this object is set to a valid value and the
printer is idle, the status returned is <noError> and the
value returned is ePrintingAnUnknownInternalPage. If
the printer is not idle (whether printing an external
job, printing an internal page or executing a self
test), a status of <genErr>
status will be returned with a value of
eNotPrintingAnInternalPage.
Setting this object to a valid value causes the
desired page to be formatted and put in the printer's
print queue. While the page is being formatted a get
on this object will return the value
ePrintingAnUnknownInternalPage, if
the time to format the page is long enough (it is
currently estimated that the time to format some pages
is as short as one millisecond).
Attempting to set this object before the page has
completed being formatted and printed will cause
<genErr> status to be
returned with a value of
eNotPrintingAnInternalPage.
After the page is in the queue, a get on this object
will return a value of eNotPrintingAnInternalPage.
Setting this object to cause another page to be
printed before the first page has completed results in
a status of <genErr> status
with a value of eNotPrintingAnInternalPage.
Likewise, if the SELF-TEST object is set to
eNonDestructiveSelfTest and that page has not printed
when this object is set to print a page, a status of
<genErr> status
with a value of eNotPrintingAnInternalPage will be
returned until the self test page has printed."
::= { test 2 }
cancel-job OBJECT-TYPE
SYNTAX INTEGER(0..32767)
ACCESS write-only
STATUS optional
DESCRIPTION
"Cancels the print job whose ID matches the value written
to the CANCEL-JOB object. The host first learns the job
ID using the CURRENT-JOB-PARSING-ID command. If the
printer has completely processed the job, the printer
responds with <badValue>. If the
value of the CURRENT-JOB-PARSING-ID is smaller than the
value written to the CANCEL-JOB object, then the printer
responds with <badValue>. When
read, returns the value of the last job ID what was
canceled, or -1 to indicate no job has been canceled.
Additional information:
If the value written matches the ID of a job that is
currently being canceled (for any reason), the printer responds with <noError>.
LaserJet 5Si uses job ID's in the range of 0..32767.
Because the ID number can wrap to zero,
CURRENT-JOB-PARSING-ID may be smaller than the value
written to this object; when this occurs, no error
will result as long as the ID is for a currently
processing job."
::= { settings-job 2 }
job-info-change-id OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(16))
ACCESS read-only
STATUS optional
DESCRIPTION
"Returns the current value of an object in the job-info
sub-tree whose value has changed. Define the object
identifier for the object whose value has changed as
job-info.required-field.optional-field.job-id. job-info
represents the OID prefix of all objects in the job-info
sub-tree. Required-field represents the OID field value
that follows the job-info prefix. Since some objects in
the job-info sub-tree have two OID fields between the
job-info prefix and the job-id, the optional-field
represents the OID field between the required-field and
the job-id field, if present. Using this definition,
the format for the JOB-INFO-CHANGE-ID binary value can
be described as follows:
Bytes 0-3 : required-field
Bytes 4-7 : optional-field, or all zeros if there
is no optional field
Bytes 8-11: Job ID.
Bytes 12-n : The value of the object job-info.
required-field.optional-field.job-id.
All multi-byte values stored in Motorola (big-endian)
format, where the most significant byte occurs first.
Additional information:
LaserJet 5Si will use this object to report changes of the
job-info-pages-printed and job-info-state objects.
Therefore, the optional-field will always be zeroes
and, because both of these are integers, the value
portion of the data will always be four bytes."
::= { settings-job 3 }
current-job-parsing-id OBJECT-TYPE
SYNTAX INTEGER(-1..32767)
ACCESS read-only
STATUS optional
DESCRIPTION
"Contains the printer assigned job identification for the
job currently being processed by the processing PDL sub-
system. The job ID is a monotonically increasing
number. The job ID may be reset to zero at power-up and
may roll over to zero after reaching some maximum
value.
Additional information:
A value of -1 is returned when the printer is
not parsing a job.
When data for a new job is detected, this object is updated (the job may or
may not turn out to be a Null Job); however, the trap does not occur until the
printer determines that it is not a Null Job (a trapped value will differ from
the previous value by one or more).
Some JOB-INFO- objects are created when the first data bytes are received. If
the printer determines that the job is a Null Job, the JOB-INFO- objects
related to the Null Job are deleted. LaserJet 5Si retains the JOB-INFO- objects for
the 32 most recent jobs that are not Null Jobs.
LaserJet 5Si resets the job ID to zero at power-up and will increment it to 32767
before rolling it to zero. To distinguish whether a power cycle or a rollover
caused an id of zero, the object prtGeneralConfigChanges can be watched and if
it increments at the same time as CURRENT-JOB-PARSING-ID goes to zero, then a
power cycle is the most likely cause."
::= { job-being-parsed 1 }
job-info-name1 OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS optional
DESCRIPTION
"Contains the first part of this print job's name. The
last OID field for this dynamic object contains the job
ID.
Additional information:
The job name is the string specified by the
NAME= parameter of the @PJL JOB command which
allows a maximum of 80 characters. The first 40 characters are in this object
and the second 40 are in JOB-INFO-NAME2. The symbol set is Roman-8.
When jobs are nested, the value assigned to this object is the name provided
by the most recent @PJL JOB NAME= command. If no name is is provided, a null
string is returned. Whenever a @PJL JOB NAME= command is received, the trap
occurs even if the name is the same."
::= { job-info 1 }
job-info-name2 OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS optional
DESCRIPTION
"Contains the second part of this print job's name. The
last OID field for this dynamic object contains the job
ID.
Additional information:
See JOB-INFO-NAME1."
::= { job-info 2 }
job-info-stage OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-only
STATUS optional
DESCRIPTION
"Indicates what printer sub-systems are currently
processing this print job. The last OID field for this
dynamic object contains the job ID.
cSourceSubsystem - some of the job is in the printer
I/O subsystem.
cProcessingSubsystem - some of the job is in the
printer imaging processing subsystem.
cDestinationSubsystem - some of the job is being
printed.
Additional information:
For LaserJet 5Si cSourceSubsystem and cProcessingSubsystem
will always be set and cleared together.
A non-printing job will never set cDestinationSubsystem.
When a page is ready to be printed,
cDestinationSubsystem will be set even if
a page of a previous job is currently being printed. cDestinationSubsystem
remains set until the last page of the job has reached an output bin.
If a
page requires extensive processing and allows all the previous pages of a
job to complete printing cDestinationSubsystem will remain set
until the last page of the job is closed."
::= { job-info 10 }
job-info-io-source OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION
"Indicates which I/O source, the print job was received
over. The value maps to port numbering scheme supported
in the DEVICE/SOURCE-SUBSYSTEM/IO/PORTS sub-tree."
::= { job-info 11 }
job-info-pages-processed OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION
"Indicates the number of pages processed by the
processing subsystem. If neither the cSourceSubsystem
or the cProcessingSubsystem items are in the associated
JOB-INFO-STAGE object, then this object contains the
total number of pages processed for this job. The last
OID field for this dynamic object contains the job ID.
Additional information:
This object is incremented by one when a page is
processed, regardless of the number of pages that are printed as a result of
the single page processed. In other words, it does not matter how many
identical copies of a page are printed, or no pages may be printed if
operating in silent run mode, this count is incremented only once.
A page is considered processed when all of the input data has been processed
for a page; the image of the page is not
necessarily completely formed."
::= { job-info 12 }
job-info-pages-printed OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION
"Indicates the number of pages printed by the destination
subsystem. If non of the cSourceSubsystem,
cProcessingSubsystem or cDestinationSubsystem items are
in the associated JOB-INFO-STAGE object, then this
object contains the total number of pages printed for
this job. This value may increase by two each time for
duplex jobs. The last OID field for this dynamic object
contains the job ID.
Additional information:
If multiple copies of a page are printed, each copy
is counted individually."
::= { job-info 13 }
job-info-size OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION
"Indicates the number of bytes of data processed by the
processing subsystem. If neither of the
cSourceSubsystem or cProcessingSubsystem items are in
the associated JOB-INFO-STAGE object, then this object
contains the size of this job, in bytes. The last OID
field for this dynamic object contains the job ID.
Additional information:
This count may be incremented by values other than one
as blocks of data are processed; blocks of data (which may be as large as 2K
bytes) will be processed in a varying amount of time.
When a job completes, this count may not be the same as the
total number of bytes sent to the printer since some data before or after the
job may be considered to be outside the job. Also, for ill-formed PostScript
jobs (ones that do not use the ENTER LANGUAGE command) will be reported as
having approximately 256 extra bytes due to the way the language switching
is accomplished."
::= { job-info 14 }
job-info-state OBJECT-TYPE
SYNTAX INTEGER {
eAborted(3),
eWaitingForResources(4),
ePrinted(5),
eTerminating(7),
eCancelled(10),
eProcessing(11)
}
ACCESS read-only
STATUS optional
DESCRIPTION
"Indicates the state of the job. The last OID field for
this dynamic object contains the job ID.
eAborted - the print job was aborted.
eWaitingForResources - the print job requires
resources that are not currently available.
ePrinted - the job has printed. The related JOB-INFO-
OUTCOME object indicates if any problems were
encountered while the job was processed.
eRetained - the job can be reprinted.
eTerminating - the job was aborted or cancelled and is
currently is terminating.
eInterrupted - the job has been interrupted. The job
can be continued.
ePaused - the job has been paused. The job can be
continuted.
eCancelled - the job has been cancelled.
eProcessing - the job is currently being printed
normally.
Additional information:
"
::= { job-info 15 }
job-info-outcome OBJECT-TYPE
SYNTAX INTEGER {
eOk(3),
eWarningsEncountered(4),
eErrorsEncountered(5)
}
ACCESS read-only
STATUS optional
DESCRIPTION
"Indicates if any warning or error conditions were
encountered while processing the assoicated job. The
last OID field for this dynamic object contains the job
ID."
::= { job-info 19 }
job-info-outbins-used OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-only
STATUS optional
DESCRIPTION
"Indicates which output bins this job has delivered
printed pages to. The last OID field for this dynamic
object contains the job ID.
Additional information:
This is the logical bin. If a bin is used as an
overflow bin, then its bit will be set as well.
cOutbin1 is the top/face-down bin.
cOutbin2 is the left/face-up bin."
::= { job-info 20 }
job-info-physical-outbins-used OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-only
STATUS optional
DESCRIPTION
"Indicates which physical output bins this job has
delivered printed pages to. The last OID field for this
dynamic object contains the job ID.
Additional information:
Bits in this object are set only if printed pages were
delivered to an external paper handling device. This object is supported
regardless of whether or not an external device is installed. The bits set map
to the
device's bins in a device specific manner. If the device does not report to
the formatter which bins are used, then no bits will be set.
For the HCO, the bins map to the bits as follows:
cOutbin1--Face-up bin
cOutbin2--Bin1
cOutbin3--Bin2
cOutbin4--Bin3
cOutbin5--Bin4
cOutbin6--Bin5
cOutbin7--Bin6
cOutbin8--Bin7
cOutbin9--Bin8"
::= { job-info 22 }
job-info-attr-1 OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(1..80))
ACCESS read-only
STATUS optional
DESCRIPTION
"Returns the value that was set in PJL via the SET
JOBATTR= command. Attribute objects are saved
sequentially, starting with 1, after the start of a job.
If more attributes are set than there are objects to
store them, the excess JOBATTR values are ignored. If
the corresponding SET JOBATTR= command has not been
received when a get is done for this object, a status of
<noSuchName> will be returned."
::= { job-info-attribute 1 }
job-info-attr-2 OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(1..80))
ACCESS read-only
STATUS optional
DESCRIPTION
"Returns the value that was set in PJL via the SET
JOBATTR= command. See JOB-INFO-ATTR-1 for details."
::= { job-info-attribute 2 }
job-info-attr-3 OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(1..80))
ACCESS read-only
STATUS optional
DESCRIPTION
"Returns the value that was set in PJL via the SET
JOBATTR= command. See JOB-INFO-ATTR-1 for details."
::= { job-info-attribute 3 }
job-info-attr-4 OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(1..80))
ACCESS read-only
STATUS optional
DESCRIPTION
"Returns the value that was set in PJL via the SET
JOBATTR= command. See JOB-INFO-ATTR-1 for details."
::= { job-info-attribute 4 }
job-info-attr-5 OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(1..80))
ACCESS read-only
STATUS optional
DESCRIPTION
"Returns the value that was set in PJL via the SET
JOBATTR= command. See JOB-INFO-ATTR-1 for details."
::= { job-info-attribute 5 }
job-info-attr-6 OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(1..80))
ACCESS read-only
STATUS optional
DESCRIPTION
"Returns the value that was set in PJL via the SET
JOBATTR= command. See JOB-INFO-ATTR-1 for details."
::= { job-info-attribute 6 }
job-info-attr-7 OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(1..80))
ACCESS read-only
STATUS optional
DESCRIPTION
"Returns the value that was set in PJL via the SET
JOBATTR= command. See JOB-INFO-ATTR-1 for details."
::= { job-info-attribute 7 }
job-info-attr-8 OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(1..80))
ACCESS read-only
STATUS optional
DESCRIPTION
"Returns the value that was set in PJL via the SET
JOBATTR= command. See JOB-INFO-ATTR-1 for details."
::= { job-info-attribute 8 }
job-info-attr-9 OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(1..80))
ACCESS read-only
STATUS optional
DESCRIPTION
"Returns the value that was set in PJL via the SET
JOBATTR= command. See JOB-INFO-ATTR-1 for details."
::= { job-info-attribute 9 }
job-info-attr-10 OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(1..80))
ACCESS read-only
STATUS optional
DESCRIPTION
"Returns the value that was set in PJL via the SET
JOBATTR= command. See JOB-INFO-ATTR-1 for details."
::= { job-info-attribute 10 }
job-info-attr-11 OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(1..80))
ACCESS read-only
STATUS optional
DESCRIPTION
"Returns the value that was set in PJL via the SET
JOBATTR= command. See JOB-INFO-ATTR-1 for details."
::= { job-info-attribute 11 }
job-info-attr-12 OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(1..80))
ACCESS read-only
STATUS optional
DESCRIPTION
"Returns the value that was set in PJL via the SET
JOBATTR= command. See JOB-INFO-ATTR-1 for details."
::= { job-info-attribute 12 }
job-info-attr-13 OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(1..80))
ACCESS read-only
STATUS optional
DESCRIPTION
"Returns the value that was set in PJL via the SET
JOBATTR= command. See JOB-INFO-ATTR-1 for details."
::= { job-info-attribute 13 }
job-info-attr-14 OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(1..80))
ACCESS read-only
STATUS optional
DESCRIPTION
"Returns the value that was set in PJL via the SET
JOBATTR= command. See JOB-INFO-ATTR-1 for details."
::= { job-info-attribute 14 }
job-info-attr-15 OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(1..80))
ACCESS read-only
STATUS optional
DESCRIPTION
"Returns the value that was set in PJL via the SET
JOBATTR= command. See JOB-INFO-ATTR-1 for details."
::= { job-info-attribute 15 }
job-info-attr-16 OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(1..80))
ACCESS read-only
STATUS optional
DESCRIPTION
"Returns the value that was set in PJL via the SET
JOBATTR= command. See JOB-INFO-ATTR-1 for details."
::= { job-info-attribute 16 }
job-info-attr-17 OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(1..80))
ACCESS read-only
STATUS optional
DESCRIPTION
"Returns the value that was set in PJL via the SET
JOBATTR= command. See JOB-INFO-ATTR-1 for details."
::= { job-info-attribute 17 }
job-info-attr-18 OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(1..80))
ACCESS read-only
STATUS optional
DESCRIPTION
"Returns the value that was set in PJL via the SET
JOBATTR= command. See JOB-INFO-ATTR-1 for details."
::= { job-info-attribute 18 }
job-info-attr-19 OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(1..80))
ACCESS read-only
STATUS optional
DESCRIPTION
"Returns the value that was set in PJL via the SET
JOBATTR= command. See JOB-INFO-ATTR-1 for details."
::= { job-info-attribute 19 }
job-info-attr-20 OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(1..80))
ACCESS read-only
STATUS optional
DESCRIPTION
"Returns the value that was set in PJL via the SET
JOBATTR= command. See JOB-INFO-ATTR-1 for details."
::= { job-info-attribute 20 }
job-info-attr-21 OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(1..80))
ACCESS read-only
STATUS optional
DESCRIPTION
"Returns the value that was set in PJL via the SET
JOBATTR= command. See JOB-INFO-ATTR-1 for details."
::= { job-info-attribute 21 }
job-info-attr-22 OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(1..80))
ACCESS read-only
STATUS optional
DESCRIPTION
"Returns the value that was set in PJL via the SET
JOBATTR= command. See JOB-INFO-ATTR-1 for details."
::= { job-info-attribute 22 }
job-info-attr-23 OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(1..80))
ACCESS read-only
STATUS optional
DESCRIPTION
"Returns the value that was set in PJL via the SET
JOBATTR= command. See JOB-INFO-ATTR-1 for details."
::= { job-info-attribute 23 }
job-info-attr-24 OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(1..80))
ACCESS read-only
STATUS optional
DESCRIPTION
"Returns the value that was set in PJL via the SET
JOBATTR= command. See JOB-INFO-ATTR-1 for details."
::= { job-info-attribute 24 }
job-info-attr-25 OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(1..80))
ACCESS read-only
STATUS optional
DESCRIPTION
"Returns the value that was set in PJL via the SET
JOBATTR= command. See JOB-INFO-ATTR-1 for details."
::= { job-info-attribute 25 }
job-info-attr-26 OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(1..80))
ACCESS read-only
STATUS optional
DESCRIPTION
"Returns the value that was set in PJL via the SET
JOBATTR= command. See JOB-INFO-ATTR-1 for details."
::= { job-info-attribute 26 }
job-info-attr-27 OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(1..80))
ACCESS read-only
STATUS optional
DESCRIPTION
"Returns the value that was set in PJL via the SET
JOBATTR= command. See JOB-INFO-ATTR-1 for details."
::= { job-info-attribute 27 }
job-info-attr-28 OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(1..80))
ACCESS read-only
STATUS optional
DESCRIPTION
"Returns the value that was set in PJL via the SET
JOBATTR= command. See JOB-INFO-ATTR-1 for details."
::= { job-info-attribute 28 }
job-info-attr-29 OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(1..80))
ACCESS read-only
STATUS optional
DESCRIPTION
"Returns the value that was set in PJL via the SET
JOBATTR= command. See JOB-INFO-ATTR-1 for details."
::= { job-info-attribute 29 }
job-info-attr-30 OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(1..80))
ACCESS read-only
STATUS optional
DESCRIPTION
"Returns the value that was set in PJL via the SET
JOBATTR= command. See JOB-INFO-ATTR-1 for details."
::= { job-info-attribute 30 }
job-info-attr-31 OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(1..80))
ACCESS read-only
STATUS optional
DESCRIPTION
"Returns the value that was set in PJL via the SET
JOBATTR= command. See JOB-INFO-ATTR-1 for details."
::= { job-info-attribute 31 }
job-info-attr-32 OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(1..80))
ACCESS read-only
STATUS optional
DESCRIPTION
"Returns the value that was set in PJL via the SET
JOBATTR= command. See JOB-INFO-ATTR-1 for details."
::= { job-info-attribute 32 }
error1-time-stamp OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION
"Contains a time stamp indicating when error 1
occurred. Example time stamps include the actual time
the error occurred (in seconds since Jan. 1, 1970), and
the total engine page count. The device POS documents
the meaning of the time stamp.
Additional information:
In LaserJet 5Si this item contains the engine
page count when the error occurred. A value of zero
means 'no error'.
See ERROR1-CODE for an explanation of the order used
for storing errors."
::= { error1 1 }
error1-code OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION
"Contains a device specific error code. Each device POS
should list what errors are logged to the error log and
the meaning of each supported error code value.
Additional information:
Contains a device specific error code. A value
of zero means 'no error'.
The error number is returned in the upper 16 bits.
If it is 68,69,79,
or 80, then the sub code is returned in the lower 16 bits (eg. 68 0019, where
the subcode is already a hexadecimal value).
If the error number is any other number, then the 1st sub code (XX)
will be in bits 15-8 and the 2nd sub code (YY) will be in bits 7-0 (eg.
55.04.02) where XX=04 and YY=02).
Example: If the error is 68 001A, then the value returned will be 4456474.
To break it down: 4456474 = 0x0044001A
The upper 16 bits: 0x0044 = 68
The lower 16 bits: 0x001A = 001A
Which is the error: 68 001A
Example: If the error is 55.04.241, then the error code will be 3605745.
To break it down: 3605745 = 0x003704F1
The upper 16 bits: 0x0037 = 55
The upper byte of the lower 16 bits: 0x04 = 04
The lower byte of the lower 16 bits: 0xF1 = 241
Which is the error: 55.04.241
ERROR1- is the oldest error in the log. Errors are added until ERROR50- is
reached. If more errors occur, ERROR1- is replaced by moving all error entries
down one position and adding the newest error as ERROR50-"
::= { error1 2 }
error2-time-stamp OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION
"Contains a time stamp indicating when error 2
occurred. Example time stamps include the actual time
the error occurred (in seconds since Jan. 1, 1970), and
the total engine page count. The device POS documents
the meaning of the time stamp.
Additional information:
See ERROR1-TIME-STAMP."
::= { error2 1 }
error2-code OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION
"Contains a device specific error code. Each device POS
should list what errors are logged to the error log and
the meaning of each supported error code value.
Additional information:
See ERROR1-CODE."
::= { error2 2 }
error3-time-stamp OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION
"Contains a time stamp indicating when error 3
occurred. Example time stamps include the actual time
the error occurred (in seconds since Jan. 1, 1970), and
the total engine page count. The device POS documents
the meaning of the time stamp.
Additional information:
See ERROR1-TIME-STAMP."
::= { error3 1 }
error3-code OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION
"Contains a device specific error code. Each device POS
should list what errors are logged to the error log and
the meaning of each supported error code value.
Additional information:
See ERROR1-CODE."
::= { error3 2 }
error4-time-stamp OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION
"Contains a time stamp indicating when error 4
occurred. Example time stamps include the actual time
the error occurred (in seconds since Jan. 1, 1970), and
the total engine page count. The device POS documents
the meaning of the time stamp.
Additional information:
See ERROR1-TIME-STAMP."
::= { error4 1 }
error4-code OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION
"Contains a device specific error code. Each device POS
should list what errors are logged to the error log and
the meaning of each supported error code value.
Additional information:
See ERROR1-CODE."
::= { error4 2 }
error5-time-stamp OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION
"Contains a time stamp indicating when error 5
occurred. Example time stamps include the actual time
the error occurred (in seconds since Jan. 1, 1970), and
the total engine page count. The device POS documents
the meaning of the time stamp.
Additional information:
See ERROR1-TIME-STAMP."
::= { error5 1 }
error5-code OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION
"Contains a device specific error code. Each device POS
should list what errors are logged to the error log and
the meaning of each supported error code value.
Additional information:
See ERROR1-CODE."
::= { error5 2 }
error6-time-stamp OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION
"Contains a time stamp indicating when error 6
occurred. Example time stamps include the actual time
the error occurred (in seconds since Jan. 1, 1970), and
the total engine page count. The device POS documents
the meaning of the time stamp.
Additional information:
See ERROR1-TIME-STAMP."
::= { error6 1 }
error6-code OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION
"Contains a device specific error code. Each device POS
should list what errors are logged to the error log and
the meaning of each supported error code value.
Additional information:
See ERROR1-CODE."
::= { error6 2 }
error7-time-stamp OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION
"Contains a time stamp indicating when error 7
occurred. Example time stamps include the actual time
the error occurred (in seconds since Jan. 1, 1970), and
the total engine page count. The device POS documents
the meaning of the time stamp.
Additional information:
See ERROR1-TIME-STAMP."
::= { error7 1 }
error7-code OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION
"Contains a device specific error code. Each device POS
should list what errors are logged to the error log and
the meaning of each supported error code value.
Additional information:
See ERROR1-CODE."
::= { error7 2 }
error8-time-stamp OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION
"Contains a time stamp indicating when error 8
occurred. Example time stamps include the actual time
the error occurred (in seconds since Jan. 1, 1970), and
the total engine page count. The device POS documents
the meaning of the time stamp.
Additional information:
See ERROR1-TIME-STAMP."
::= { error8 1 }
error8-code OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION
"Contains a device specific error code. Each device POS
should list what errors are logged to the error log and
the meaning of each supported error code value.
Additional information:
See ERROR1-CODE."
::= { error8 2 }
error9-time-stamp OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION
"Contains a time stamp indicating when error 9
occurred. Example time stamps include the actual time
the error occurred (in seconds since Jan. 1, 1970), and
the total engine page count. The device POS documents
the meaning of the time stamp.
Additional information:
See ERROR1-TIME-STAMP."
::= { error9 1 }
error9-code OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION
"Contains a device specific error code. Each device POS
should list what errors are logged to the error log and
the meaning of each supported error code value.
Additional information:
See ERROR1-CODE."
::= { error9 2 }
error10-time-stamp OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION
"Contains a time stamp indicating when error
10 occurred. Example time stamps include the actual
time the error occurred (in seconds since Jan. 1, 1970),
and the total engine page count. The device POS
documents the meaning of the time stamp.
Additional information:
See ERROR1-TIME-STAMP."
::= { error10 1 }
error10-code OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION
"Contains a device specific error code. Each device POS
should list what errors are logged to the error log and
the meaning of each supported error code value.
Additional information:
See ERROR1-CODE."
::= { error10 2 }
error11-time-stamp OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION
"Contains a time stamp indicating when error
11 occurred. Example time stamps include the actual
time the error occurred (in seconds since Jan. 1, 1970),
and the total engine page count. The device POS
documents the meaning of the time stamp.
Additional information:
See ERROR1-TIME-STAMP."
::= { error11 1 }
error11-code OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION
"Contains a device specific error code. Each device POS
should list what errors are logged to the error log and
the meaning of each supported error code value.
Additional information:
See ERROR1-CODE."
::= { error11 2 }
error12-time-stamp OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION
"Contains a time stamp indicating when error
12 occurred. Example time stamps include the actual
time the error occurred (in seconds since Jan. 1, 1970),
and the total engine page count. The device POS
documents the meaning of the time stamp.
Additional information:
See ERROR1-TIME-STAMP."
::= { error12 1 }
error12-code OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION
"Contains a device specific error code. Each device POS
should list what errors are logged to the error log and
the meaning of each supported error code value.
Additional information:
See ERROR1-CODE."
::= { error12 2 }
error13-time-stamp OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION
"Contains a time stamp indicating when error
13 occurred. Example time stamps include the actual
time the error occurred (in seconds since Jan. 1, 1970),
and the total engine page count. The device POS
documents the meaning of the time stamp.
Additional information:
See ERROR1-TIME-STAMP."
::= { error13 1 }
error13-code OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION
"Contains a device specific error code. Each device POS
should list what errors are logged to the error log and
the meaning of each supported error code value.
Additional information:
See ERROR1-CODE."
::= { error13 2 }
error14-time-stamp OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION
"Contains a time stamp indicating when error
14 occurred. Example time stamps include the actual
time the error occurred (in seconds since Jan. 1, 1970),
and the total engine page count. The device POS
documents the meaning of the time stamp.
Additional information:
See ERROR1-TIME-STAMP."
::= { error14 1 }
error14-code OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION
"Contains a device specific error code. Each device POS
should list what errors are logged to the error log and
the meaning of each supported error code value.
Additional information:
See ERROR1-CODE."
::= { error14 2 }
error15-time-stamp OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION
"Contains a time stamp indicating when error
15 occurred. Example time stamps include the actual
time the error occurred (in seconds since Jan. 1, 1970),
and the total engine page count. The device POS
documents the meaning of the time stamp.
Additional information:
See ERROR1-TIME-STAMP."
::= { error15 1 }
error15-code OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION
"Contains a device specific error code. Each device POS
should list what errors are logged to the error log and
the meaning of each supported error code value.
Additional information:
See ERROR1-CODE."
::= { error15 2 }
error16-time-stamp OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION
"Contains a time stamp indicating when error
16 occurred. Example time stamps include the actual
time the error occurred (in seconds since Jan. 1, 1970),
and the total engine page count. The device POS
documents the meaning of the time stamp.
Additional information:
See ERROR1-TIME-STAMP."
::= { error16 1 }
error16-code OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION
"Contains a device specific error code. Each device POS
should list what errors are logged to the error log and
the meaning of each supported error code value.
Additional information:
See ERROR1-CODE."
::= { error16 2 }
error17-time-stamp OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION
"Contains a time stamp indicating when error
17 occurred. Example time stamps include the actual
time the error occurred (in seconds since Jan. 1, 1970),
and the total engine page count. The device POS
documents the meaning of the time stamp.
Additional information:
See ERROR1-TIME-STAMP."
::= { error17 1 }
error17-code OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION
"Contains a device specific error code. Each device POS
should list what errors are logged to the error log and
the meaning of each supported error code value.
Additional information:
See ERROR1-CODE."
::= { error17 2 }
error18-time-stamp OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION
"Contains a time stamp indicating when error
18 occurred. Example time stamps include the actual
time the error occurred (in seconds since Jan. 1, 1970),
and the total engine page count. The device POS
documents the meaning of the time stamp.
Additional information:
See ERROR1-TIME-STAMP."
::= { error18 1 }
error18-code OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION
"Contains a device specific error code. Each device POS
should list what errors are logged to the error log and
the meaning of each supported error code value.
Additional information:
See ERROR1-CODE."
::= { error18 2 }
error19-time-stamp OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION
"Contains a time stamp indicating when error
19 occurred. Example time stamps include the actual
time the error occurred (in seconds since Jan. 1, 1970),
and the total engine page count. The device POS
documents the meaning of the time stamp.
Additional information:
See ERROR1-TIME-STAMP."
::= { error19 1 }
error19-code OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION
"Contains a device specific error code. Each device POS
should list what errors are logged to the error log and
the meaning of each supported error code value.
Additional information:
See ERROR1-CODE."
::= { error19 2 }
error20-time-stamp OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION
"Contains a time stamp indicating when error
20 occurred. Example time stamps include the actual
time the error occurred (in seconds since Jan. 1, 1970),
and the total engine page count. The device POS
documents the meaning of the time stamp.
Additional information:
See ERROR1-TIME-STAMP."
::= { error20 1 }
error20-code OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION
"Contains a device specific error code. Each device POS
should list what errors are logged to the error log and
the meaning of each supported error code value.
Additional information:
See ERROR1-CODE."
::= { error20 2 }
error21-time-stamp OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION
"Contains a time stamp indicating when error
21 occurred. Example time stamps include the actual
time the error occurred (in seconds since Jan. 1, 1970),
and the total engine page count. The device POS
documents the meaning of the time stamp.
Additional information:
See ERROR1-TIME-STAMP."
::= { error21 1 }
error21-code OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION
"Contains a device specific error code. Each device POS
should list what errors are logged to the error log and
the meaning of each supported error code value.
Additional information:
See ERROR1-CODE."
::= { error21 2 }
error22-time-stamp OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION
"Contains a time stamp indicating when error
22 occurred. Example time stamps include the actual
time the error occurred (in seconds since Jan. 1, 1970),
and the total engine page count. The device POS
documents the meaning of the time stamp.
Additional information:
See ERROR1-TIME-STAMP."
::= { error22 1 }
error22-code OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION
"Contains a device specific error code. Each device POS
should list what errors are logged to the error log and
the meaning of each supported error code value.
Additional information:
See ERROR1-CODE."
::= { error22 2 }
error23-time-stamp OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION
"Contains a time stamp indicating when error
23 occurred. Example time stamps include the actual
time the error occurred (in seconds since Jan. 1, 1970),
and the total engine page count. The device POS
documents the meaning of the time stamp.
Additional information:
See ERROR1-TIME-STAMP."
::= { error23 1 }
error23-code OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION
"Contains a device specific error code. Each device POS
should list what errors are logged to the error log and
the meaning of each supported error code value.
Additional information:
See ERROR1-CODE."
::= { error23 2 }
error24-time-stamp OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION
"Contains a time stamp indicating when error
24 occurred. Example time stamps include the actual
time the error occurred (in seconds since Jan. 1, 1970),
and the total engine page count. The device POS
documents the meaning of the time stamp.
Additional information:
See ERROR1-TIME-STAMP."
::= { error24 1 }
error24-code OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION
"Contains a device specific error code. Each device POS
should list what errors are logged to the error log and
the meaning of each supported error code value.
Additional information:
See ERROR1-CODE."
::= { error24 2 }
error25-time-stamp OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION
"Contains a time stamp indicating when error
25 occurred. Example time stamps include the actual
time the error occurred (in seconds since Jan. 1, 1970),
and the total engine page count. The device POS
documents the meaning of the time stamp.
Additional information:
See ERROR1-TIME-STAMP."
::= { error25 1 }
error25-code OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION
"Contains a device specific error code. Each device POS
should list what errors are logged to the error log and
the meaning of each supported error code value.
Additional information:
See ERROR1-CODE."
::= { error25 2 }
error26-time-stamp OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION
"Contains a time stamp indicating when error
26 occurred. Example time stamps include the actual
time the error occurred (in seconds since Jan. 1, 1970),
and the total engine page count. The device POS
documents the meaning of the time stamp.
Additional information:
See ERROR1-TIME-STAMP."
::= { error26 1 }
error26-code OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION
"Contains a device specific error code. Each device POS
should list what errors are logged to the error log and
the meaning of each supported error code value.
Additional information:
See ERROR1-CODE."
::= { error26 2 }
error27-time-stamp OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION
"Contains a time stamp indicating when error
27 occurred. Example time stamps include the actual
time the error occurred (in seconds since Jan. 1, 1970),
and the total engine page count. The device POS
documents the meaning of the time stamp.
Additional information:
See ERROR1-TIME-STAMP."
::= { error27 1 }
error27-code OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION
"Contains a device specific error code. Each device POS
should list what errors are logged to the error log and
the meaning of each supported error code value.
Additional information:
See ERROR1-CODE."
::= { error27 2 }
error28-time-stamp OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION
"Contains a time stamp indicating when error
28 occurred. Example time stamps include the actual
time the error occurred (in seconds since Jan. 1, 1970),
and the total engine page count. The device POS
documents the meaning of the time stamp.
Additional information:
See ERROR1-TIME-STAMP."
::= { error28 1 }
error28-code OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION
"Contains a device specific error code. Each device POS
should list what errors are logged to the error log and
the meaning of each supported error code value.
Additional information:
See ERROR1-CODE."
::= { error28 2 }
error29-time-stamp OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION
"Contains a time stamp indicating when error
29 occurred. Example time stamps include the actual
time the error occurred (in seconds since Jan. 1, 1970),
and the total engine page count. The device POS
documents the meaning of the time stamp.
Additional information:
See ERROR1-TIME-STAMP."
::= { error29 1 }
error29-code OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION
"Contains a device specific error code. Each device POS
should list what errors are logged to the error log and
the meaning of each supported error code value.
Additional information:
See ERROR1-CODE."
::= { error29 2 }
error30-time-stamp OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION
"Contains a time stamp indicating when error
30 occurred. Example time stamps include the actual
time the error occurred (in seconds since Jan. 1, 1970),
and the total engine page count. The device POS
documents the meaning of the time stamp.
Additional information:
See ERROR1-TIME-STAMP."
::= { error30 1 }
error30-code OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION
"Contains a device specific error code. Each device POS
should list what errors are logged to the error log and
the meaning of each supported error code value.
Additional information:
See ERROR1-CODE."
::= { error30 2 }
error31-time-stamp OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION
"Contains a time stamp indicating when error
31 occurred. Example time stamps include the actual
time the error occurred (in seconds since Jan. 1, 1970),
and the total engine page count. The device POS
documents the meaning of the time stamp.
Additional information:
See ERROR1-TIME-STAMP."
::= { error31 1 }
error31-code OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION
"Contains a device specific error code. Each device POS
should list what errors are logged to the error log and
the meaning of each supported error code value.
Additional information:
See ERROR1-CODE."
::= { error31 2 }
error32-time-stamp OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION
"Contains a time stamp indicating when error
32 occurred. Example time stamps include the actual
time the error occurred (in seconds since Jan. 1, 1970),
and the total engine page count. The device POS
documents the meaning of the time stamp.
Additional information:
See ERROR1-TIME-STAMP."
::= { error32 1 }
error32-code OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION
"Contains a device specific error code. Each device POS
should list what errors are logged to the error log and
the meaning of each supported error code value.
Additional information:
See ERROR1-CODE."
::= { error32 2 }
error33-time-stamp OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION
"Contains a time stamp indicating when error
33 occurred. Example time stamps include the actual
time the error occurred (in seconds since Jan. 1, 1970),
and the total engine page count. The device POS
documents the meaning of the time stamp.
Additional information:
See ERROR1-TIME-STAMP."
::= { error33 1 }
error33-code OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION
"Contains a device specific error code. Each device POS
should list what errors are logged to the error log and
the meaning of each supported error code value.
Additional information:
See ERROR1-CODE."
::= { error33 2 }
error34-time-stamp OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION
"Contains a time stamp indicating when error
34 occurred. Example time stamps include the actual
time the error occurred (in seconds since Jan. 1, 1970),
and the total engine page count. The device POS
documents the meaning of the time stamp.
Additional information:
See ERROR1-TIME-STAMP."
::= { error34 1 }
error34-code OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION
"Contains a device specific error code. Each device POS
should list what errors are logged to the error log and
the meaning of each supported error code value.
Additional information:
See ERROR1-CODE."
::= { error34 2 }
error35-time-stamp OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION
"Contains a time stamp indicating when error
35 occurred. Example time stamps include the actual
time the error occurred (in seconds since Jan. 1, 1970),
and the total engine page count. The device POS
documents the meaning of the time stamp.
Additional information:
See ERROR1-TIME-STAMP."
::= { error35 1 }
error35-code OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION
"Contains a device specific error code. Each device POS
should list what errors are logged to the error log and
the meaning of each supported error code value.
Additional information:
See ERROR1-CODE."
::= { error35 2 }
error36-time-stamp OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION
"Contains a time stamp indicating when error
36 occurred. Example time stamps include the actual
time the error occurred (in seconds since Jan. 1, 1970),
and the total engine page count. The device POS
documents the meaning of the time stamp.
Additional information:
See ERROR1-TIME-STAMP."
::= { error36 1 }
error36-code OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION
"Contains a device specific error code. Each device POS
should list what errors are logged to the error log and
the meaning of each supported error code value.
Additional information:
See ERROR1-CODE."
::= { error36 2 }
error37-time-stamp OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION
"Contains a time stamp indicating when error
37 occurred. Example time stamps include the actual
time the error occurred (in seconds since Jan. 1, 1970),
and the total engine page count. The device POS
documents the meaning of the time stamp.
Additional information:
See ERROR1-TIME-STAMP."
::= { error37 1 }
error37-code OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION
"Contains a device specific error code. Each device POS
should list what errors are logged to the error log and
the meaning of each supported error code value.
Additional information:
See ERROR1-CODE."
::= { error37 2 }
error38-time-stamp OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION
"Contains a time stamp indicating when error
38 occurred. Example time stamps include the actual
time the error occurred (in seconds since Jan. 1, 1970),
and the total engine page count. The device POS
documents the meaning of the time stamp.
Additional information:
See ERROR1-TIME-STAMP."
::= { error38 1 }
error38-code OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION
"Contains a device specific error code. Each device POS
should list what errors are logged to the error log and
the meaning of each supported error code value.
Additional information:
See ERROR1-CODE."
::= { error38 2 }
error39-time-stamp OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION
"Contains a time stamp indicating when error
39 occurred. Example time stamps include the actual
time the error occurred (in seconds since Jan. 1, 1970),
and the total engine page count. The device POS
documents the meaning of the time stamp.
Additional information:
See ERROR1-TIME-STAMP."
::= { error39 1 }
error39-code OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION
"Contains a device specific error code. Each device POS
should list what errors are logged to the error log and
the meaning of each supported error code value.
Additional information:
See ERROR1-CODE."
::= { error39 2 }
error40-time-stamp OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION
"Contains a time stamp indicating when error
40 occurred. Example time stamps include the actual
time the error occurred (in seconds since Jan. 1, 1970),
and the total engine page count. The device POS
documents the meaning of the time stamp.
Additional information:
See ERROR1-TIME-STAMP."
::= { error40 1 }
error40-code OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION
"Contains a device specific error code. Each device POS
should list what errors are logged to the error log and
the meaning of each supported error code value.
Additional information:
See ERROR1-CODE."
::= { error40 2 }
error41-time-stamp OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION
"Contains a time stamp indicating when error
41 occurred. Example time stamps include the actual
time the error occurred (in seconds since Jan. 1, 1970),
and the total engine page count. The device POS
documents the meaning of the time stamp.
Additional information:
See ERROR1-TIME-STAMP."
::= { error41 1 }
error41-code OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION
"Contains a device specific error code. Each device POS
should list what errors are logged to the error log and
the meaning of each supported error code value.
Additional information:
See ERROR1-CODE."
::= { error41 2 }
error42-time-stamp OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION
"Contains a time stamp indicating when error
42 occurred. Example time stamps include the actual
time the error occurred (in seconds since Jan. 1, 1970),
and the total engine page count. The device POS
documents the meaning of the time stamp.
Additional information:
See ERROR1-TIME-STAMP."
::= { error42 1 }
error42-code OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION
"Contains a device specific error code. Each device POS
should list what errors are logged to the error log and
the meaning of each supported error code value.
Additional information:
See ERROR1-CODE."
::= { error42 2 }
error43-time-stamp OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION
"Contains a time stamp indicating when error
43 occurred. Example time stamps include the actual
time the error occurred (in seconds since Jan. 1, 1970),
and the total engine page count. The device POS
documents the meaning of the time stamp.
Additional information:
See ERROR1-TIME-STAMP."
::= { error43 1 }
error43-code OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION
"Contains a device specific error code. Each device POS
should list what errors are logged to the error log and
the meaning of each supported error code value.
Additional information:
See ERROR1-CODE."
::= { error43 2 }
error44-time-stamp OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION
"Contains a time stamp indicating when error
44 occurred. Example time stamps include the actual
time the error occurred (in seconds since Jan. 1, 1970),
and the total engine page count. The device POS
documents the meaning of the time stamp.
Additional information:
See ERROR1-TIME-STAMP."
::= { error44 1 }
error44-code OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION
"Contains a device specific error code. Each device POS
should list what errors are logged to the error log and
the meaning of each supported error code value.
Additional information:
See ERROR1-CODE."
::= { error44 2 }
error45-time-stamp OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION
"Contains a time stamp indicating when error
45 occurred. Example time stamps include the actual
time the error occurred (in seconds since Jan. 1, 1970),
and the total engine page count. The device POS
documents the meaning of the time stamp.
Additional information:
See ERROR1-TIME-STAMP."
::= { error45 1 }
error45-code OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION
"Contains a device specific error code. Each device POS
should list what errors are logged to the error log and
the meaning of each supported error code value.
Additional information:
See ERROR1-CODE."
::= { error45 2 }
error46-time-stamp OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION
"Contains a time stamp indicating when error
46 occurred. Example time stamps include the actual
time the error occurred (in seconds since Jan. 1, 1970),
and the total engine page count. The device POS
documents the meaning of the time stamp.
Additional information:
See ERROR1-TIME-STAMP."
::= { error46 1 }
error46-code OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION
"Contains a device specific error code. Each device POS
should list what errors are logged to the error log and
the meaning of each supported error code value.
Additional information:
See ERROR1-CODE."
::= { error46 2 }
error47-time-stamp OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION
"Contains a time stamp indicating when error
47 occurred. Example time stamps include the actual
time the error occurred (in seconds since Jan. 1, 1970),
and the total engine page count. The device POS
documents the meaning of the time stamp.
Additional information:
See ERROR1-TIME-STAMP."
::= { error47 1 }
error47-code OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION
"Contains a device specific error code. Each device POS
should list what errors are logged to the error log and
the meaning of each supported error code value.
Additional information:
See ERROR1-CODE."
::= { error47 2 }
error48-time-stamp OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION
"Contains a time stamp indicating when error
48 occurred. Example time stamps include the actual
time the error occurred (in seconds since Jan. 1, 1970),
and the total engine page count. The device POS
documents the meaning of the time stamp.
Additional information:
See ERROR1-TIME-STAMP."
::= { error48 1 }
error48-code OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION
"Contains a device specific error code. Each device POS
should list what errors are logged to the error log and
the meaning of each supported error code value.
Additional information:
See ERROR1-CODE."
::= { error48 2 }
error49-time-stamp OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION
"Contains a time stamp indicating when error
49 occurred. Example time stamps include the actual
time the error occurred (in seconds since Jan. 1, 1970),
and the total engine page count. The device POS
documents the meaning of the time stamp.
Additional information:
See ERROR1-TIME-STAMP."
::= { error49 1 }
error49-code OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION
"Contains a device specific error code. Each device POS
should list what errors are logged to the error log and
the meaning of each supported error code value.
Additional information:
See ERROR1-CODE."
::= { error49 2 }
error50-time-stamp OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION
"Contains a time stamp indicating when error
50 occurred. Example time stamps include the actual
time the error occurred (in seconds since Jan. 1, 1970),
and the total engine page count. The device POS
documents the meaning of the time stamp.
Additional information:
See ERROR1-TIME-STAMP."
::= { error50 1 }
error50-code OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION
"Contains a device specific error code. Each device POS
should list what errors are logged to the error log and
the meaning of each supported error code value.
Additional information:
See ERROR1-CODE."
::= { error50 2 }
io-timeout OBJECT-TYPE
SYNTAX INTEGER(5..300)
ACCESS read-write
STATUS optional
DESCRIPTION
"The amount of time, in seconds, to wait for more print
job data to be received before an I/O timeout occurs.
The I/O channel being timed is the I/O channel that
received the data associated with the current print job.
If an I/O timeout occurs, the PDL processing sub-system
assumes all the data associated with the current print
job has been received, and processes the end of job in
an PDL specific manner. The POS specifies the supported
values.
Additional information:
If an I/O timeout occurs, the PDL processing
sub-system will consider it an end of job condition only if there is data from
another I/O subsystem waiting to be processed.
The supported values are 5 to 300 seconds.
Setting to a value outside the supported range returns
<badValue> status.
Although the Control Panel restricts the values that may be set, any value
within the limits may be set by this object."
::= { settings-io 1 }
io-switch OBJECT-TYPE
SYNTAX INTEGER {
eYes(1)
}
ACCESS read-only
STATUS optional
DESCRIPTION
"Indicates if the device will switch between I/O channels
when a job boundary is encountered and print job data is
available on another I/O channel."
::= { settings-io 2 }
io-buffering OBJECT-TYPE
SYNTAX INTEGER {
eOff(1),
eOn(2),
eAuto(3)
}
ACCESS read-write
STATUS optional
DESCRIPTION
"Returns or controls the manner in which the device
performs I/O data buffering. I/O data buffering allows
additional print job data to be buffered by the I/O sub-
system in an effort to allow the computer sending the
data to perform other tasks and to keep the PDL
processing sub-system busy. eOff, I/O buffering is
disabled. When eOn, I/O buffering is enabled and the
IO-BUFFER-SIZE object controls the amount of memory set
aside for I/O buffer. When eAuto, I/O buffering is
enabled and the I/O buffer size is determined
automatically by the device and the IO-BUFFER-SIZE
object is not used.
Additional information:
In a PCL-only printer, all values may be set at any
time.
When PostScript is installed and there is less than
12M of memory installed, setting this object to eOn or eAuto will cause
<badValue> to be returned.
When PostScript and a duplex unit are installed and there is less than
23M of memory installed, setting this object to eOn or eAuto will cause
<badValue> to be returned.
When PostScript and 12M (23M with duplex unit) or more are installed, all
values are valid, provided Resource Saving has not consumed the needed
memory."
::= { settings-io 5 }
io-buffer-size OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS optional
DESCRIPTION
"Returns or configures the amount of memory, in bytes,
dedicated to I/O print job data buffering. Attempting
to set to an unsupported value causes the device to use
the closest supported value. Each device POS should
document the list of supported values.
Additional information:
When IO-BUFFERING is eOff, reading this object will
return a value of zero. Attempting to set this object when IO-BUFFERING is
eOff will cause a status of <genErr> to be
returned.
When IO-BUFFERING is eAuto, the printer determines the
value of this object. Attempting to set this object when IO-BUFFERING is eAuto
will cause a status of <genErr> to be returned.
Reading this object when
IO-BUFFERING is eAuto will return the value that is currently being used by
the printer; the value is based on the printer configuration and
is as follows:
PCL-only: If 4M installed, 10240; if >4M installed, 102400 for each 1M
over 4M.
PCL & PS: If <12M installed, eAuto cannot be set; if 12M installed, 10240; if
>12M installed, 102400 for each 1M over 12M.
PCL, PS & Duplex Unit: If <23M installed, eAuto cannot be set; if 23M
installed, 10240; if
>23M installed, 102400 for each 1M over 23M.
When IO-BUFFERING is eOn, the range of values supported by this object varies
depending on the printer's configuration. The minimum value is 10240; the
maximum value is the current value of this object plus the value of
MAXIMUM-IO-BUFFERING-MEMORY. Supported values are multiples of 10240 for
values less or equal to 97280 and multiples of 102400 for values greater than
97280. Setting to an unsupported value causes the printer to substitute the
nearest supported value and to return <noError>
status."
::= { settings-io 6 }
maximum-io-buffering-memory OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION
"Returns the maximum amount of additional memory, in
bytes, that can be dedicated to buffering print job
data.
Additional information:
Memory for I/O Buffering is allocated in increments of
102400 bytes. Therefore, for each 1M (1048576 bytes) of memory added to the
printer, 1024000 bytes are made available to resource saving (and I/O
buffering) and 24576 bytes are retained until an additional 102400 byte block
can be made available. The value reported by this object is always rounded
down to the nearest multiple of 102400.
The values listed below assume that IO-BUFFERING=eOff; if
IO-BUFFERING=eOn, the value returned by this object will be reduced by
the amount of memory used by the IO-BUFFERING object.
For a PCL-only printer, the value of this object is
102400 if 4M memory is installed or all the memory over 4M.
If PostScript is installed without a duplex unit, the value of this object is
as follows:
0K if <12M memory is installed.
102400 if 12M memory is installed.
All over 12M memory installed.
If PostScript is installed with a duplex unit, the value of this object is as
follows:
0K if <23M memory is installed.
102400 if 23M memory is installed.
All over 23M memory installed."
::= { settings-io 7 }
port1-parallel-speed OBJECT-TYPE
SYNTAX INTEGER {
eSlow(1),
eFast(2)
}
ACCESS read-write
STATUS optional
DESCRIPTION
"Returns or changes the maximum parallel I/O port speed,
for port 1. This object is only supported if this port
is a parallel port. An eSlow setting causes a 10 us
busy pulse per received byte of data. An eFast setting
causes a 1.5 us busy pulse per received byte of data.
In rare cases, setting this value to eFast can cause the
parallel port to no longer transfer data reliably."
::= { port1 4 }
port1-parallel-bidirectionality OBJECT-TYPE
SYNTAX INTEGER {
eUnidirectional(1),
eBidirectional(2)
}
ACCESS read-write
STATUS optional
DESCRIPTION
"Returns or changes whether the parallel I/O port
supports bidirectional communication for port 1. This
object is only supported if this port is a parallel
port.
Additional information:
A get on this object returns the current mode
for the parallel port. Setting this object specifies whether or not
bidirectional communications will be allowed."
::= { port1 5 }
default-copies OBJECT-TYPE
SYNTAX INTEGER(1..999)
ACCESS read-write
STATUS optional
DESCRIPTION
"Returns or changes default copies. Default copies is
the default values used by the PDL to control the number
of copies of each page in the print job that are
printed. The print job can override this value. The
list of supported values should be documented in the
device POS.
Additional information:
The supported values are 1
through 999. Setting to an unsupported value causes
the printer to substitute in a snap value
and to return
<noError> status.
The snap values are as follow:
<1 snaps to 1
>999 snaps to 999"
::= { settings-pdl 4 }
form-feed OBJECT-TYPE
SYNTAX INTEGER {
eInitiateAction(1)
}
ACCESS write-only
STATUS optional
DESCRIPTION
"Instructs the PDL processing sub-system to finishing
processing the current page of the current job. Form
feed is also known as close page or eject page. If the
PDL processing sub-system is in a FORM-FEED-NEEDED
state, this causes the device to flush or finish
processing the current page of the current job. If the
device is not in the FORM-FEED-NEEDED state, an
<genErr> will occur.
Additional information:
The printer must be offline before attempting
to perform a form feed, otherwise a status
<genErr> will be returned."
::= { settings-pdl 5 }
resource-saving OBJECT-TYPE
SYNTAX INTEGER {
eOff(1),
eOn(2),
eAuto(3)
}
ACCESS read-write
STATUS optional
DESCRIPTION
"Returns or changes PDL resource saving. Resource saving
stores a PDL's permanent soft resources, like fonts,
even when another PDL is active. Resource saving is
also called environment saving. When eOff, resource
saving is disabled. When ON, resource saving is enabled
and memory is set aside for each PDL based on that PDL's
resource saving memory size object, to store that PDL's
permanent soft resources. When eAuto, resource saving
is enabled and memory space for each installed PDL is
determined automatically. The device POS should
document what values are legal when only one PDL is
installed.
Additional information:
When PCL is the only PDL installed in
LaserJet 5Si, all resource saving memory is dedicated to
PCL so eOff is the only valid value. Attempting to set this object to eAuto
or eOn with a PCL-only printer will result in a status of
<badValue> being returned.
When PostScript is installed and there is less than
13M of memory installed, the only valid value for this object is eOff.
Attempting to set this object to eOn or eAuto will cause
<badValue> to be returned.
When PostScript and a duplex unit are installed and there is less than
24M of memory installed, the only valid value for this object is eOff.
Attempting to set this object to eOn or eAuto will cause
<badValue> to be returned.
When PostScript and 13M (24M with duplex unit) or more are installed, all
values are valid, provided I/O Buffering has not consumed the needed
memory."
::= { settings-pdl 6 }
maximum-resource-saving-memory OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION
"Returns the maximum amount of additional memory, in
bytes, that can be dedicated to holding PDL permanent
soft resources.
Additional information:
The following numbers assume that IO-BUFFERING=eOff;
if IO-BUFFERING<>eOff, the following numbers will be reduced by the value of
IO-BUFFER-SIZE.
Memory for resource saving is allocated in increments of 102400 bytes.
Therefore, for each 1M (1048576 bytes) of memory added to the printer, 1024000
bytes are made available to resource saving (and I/O buffering) and 24576
bytes are retained until an additional 102400 byte block can be made
available. The value reported by this object is always rounded down to the
nearest multiple of 102400.
For a PCL-only printer, the value of this object is zero (all resource saving
memory is dedicated to PCL).
If PostScript is installed without a duplex unit, the value of this object is
as follows:
Zero if <13M memory is installed.
1024000 if 13M memory is installed and RESOURCE-SAVING=eOff.
1024000 if 13M memory is installed and RESOURCE-SAVING=eOn (note that this
value will be reduced by the amount of memory allocated to
PCL-RESOURCE-SAVING-MEMORY-SIZE and POSTSCRIPT-RESOURCE-SAVING-MEMORY-SIZE).
204800 if 13M memory is installed and RESOURCE-SAVING=eAuto.
When RESOURCE-SAVING=eAuto, 204800 bytes of each 1M over 13M memory installed
are allocated to PCL and PostScript (102400 each) with the remaining bytes
added to this object.
When RESOURCE-SAVING=eOn or eOff, all bytes over 13M memory installed are
added to this object.
If PostScript is installed with a duplex unit, the value of this object is as
follows:
Zero if <24M memory is installed.
1024000 if 24M memory is installed and RESOURCE-SAVING=eOff.
1024000 if 24M memory is installed and RESOURCE-SAVING=eOn (note that this
value will be reduced by the amount of memory allocated to
PCL-RESOURCE-SAVING-MEMORY-SIZE and POSTSCRIPT-RESOURCE-SAVING-MEMORY-SIZE).
204800 if 24M memory is installed and RESOURCE-SAVING=eAuto.
When RESOURCE-SAVING=eAuto, 204800 bytes of each 1M over 24M memory installed
are allocated to PCL and PostScript (102400 each) with the remaining bytes
added to this object.
When RESOURCE-SAVING=eOn or eOff, all bytes over 24M memory installed are
added to this object.
The above listed values returned by this object will be reduced by the amount
of memory added to PCL-RESOURCE-SAVING-MEMORY-SIZE and
POSTSCRIPT-RESOURCE-SAVING-MEMORY-SIZE when RESOURCE-SAVING=eOn."
::= { settings-pdl 7 }
default-vertical-black-resolution OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS optional
DESCRIPTION
"Returns or changes the value of the default vertical
black resolution. The units are dots per inch.
Additional information:
In LaserJet 5Si changing this OID also causes
DEFAULT-HORIZONTAL-BLACK RESOLUTION to change.
DEFAULT-HORIZONTAL-BLACK-RESOLUTION and
DEFAULT-VERTICAL-BLACK-RESOLUTION must always be the
same. The supported values are 300 and 600.
Setting to an unsupported value causes the printer
to substitute in a snap value and
to return <noError> status.
The snap values are as follow:
<450 snap to 300
>=450 snap to 600"
::= { settings-pdl 8 }
default-horizontal-black-resolution OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS optional
DESCRIPTION
"Returns or changes the value of the default horizontal
black resolution. The units are dots per inch.
Additional information:
In LaserJet 5Si changing this OID also causes
DEFAULT- VERTICAL-BLACK RESOLUTION to change.
DEFAULT- HORIZONTAL-BLACK-RESOLUTION and
DEFAULT-VERTICAL-BLACK-RESOLUTION must always be the
same. The supported values are 300 and 600.
Setting to an unsupported value causes the printer
to substitute in a snap value and to
return <noError> status.
The snap values are as follow:
<450 snap to 300
>=450 snap to 600"
::= { settings-pdl 9 }
default-page-protect OBJECT-TYPE
SYNTAX INTEGER {
eOn(2),
eAuto(3)
}
ACCESS read-write
STATUS optional
DESCRIPTION
"Returns or changes the default page protection behavior.
If eOff, the device does not reserve memory for holding
the entire raster form of a processed page. If eOn,
then memory is reserved. If eAuto, the device
determines the amount of memory to reserve.
Additional information:
Setting to eOn causes MET to be more conservative, but
it will not allocate memory to hold an entire
rasterized page."
::= { settings-pdl 10 }
default-lines-per-page OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS optional
DESCRIPTION
"Returns or changes the default number of lines per page.
The POS indicates the supported values. An unsupported
value causes the printer to use the closest supported
value, causing the printer to return the
<noError>.
Additional information:
The supported values in LaserJet 5Si are 5 to 128.
Setting to an unsupported value causes the
the printer to substitute in a snap value and to return
<noError>
status.
The snap values are as follow:
<5 snaps to 5
>128 snaps to 128"
::= { settings-pdl 11 }
default-vmi OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS optional
DESCRIPTION
"Returns or changes the default vertical motion index.
The unit of measure for VMI is centipoints per line.
The POS indicates the supported values. An unsupported
value causes the printer to use the closest supported
value, causing the printer to return
<noError>."
::= { settings-pdl 12 }
default-media-size OBJECT-TYPE
SYNTAX INTEGER {
eUSExecutive(1),
eUSLetter(2),
eUSLegal(3),
eLedger(11),
eISOandJISA4(26),
eISOandJISA3(27),
eJISB5(45),
eJISB4(46),
eJapanesePostcardDouble(72),
eMonarch(80),
eCommercial10(81),
eInternationalDL(90),
eInternationalC5(91),
eInternationalB5(100),
eCustom(101)
}
ACCESS read-write
STATUS optional
DESCRIPTION
"This indicates the default media size. A write of an
unsupported value cases an <badValue>.
Complete list of supported media sizes along
with their dimensions are listed in the ''Media Size
Table'' near the end of this document."
::= { settings-pdl 13 }
cold-reset-media-size OBJECT-TYPE
SYNTAX INTEGER {
eUSLetter(2),
eISOandJISA4(26)
}
ACCESS read-write
STATUS optional
DESCRIPTION
"Returns or sets the media size that is used as the
DEFAULT-MEDIA-SIZE when a cold reset occurs."
::= { settings-pdl 19 }
default-media-name OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-write
STATUS optional
DESCRIPTION
"Returns or sets the media name that is used until the
media name is changed by a print job command.
Additional information:
This string must be one of the
MEDIAn-NAME objects."
::= { settings-pdl 22 }
form-feed-needed OBJECT-TYPE
SYNTAX INTEGER {
eFalse(1),
eTrue(2)
}
ACCESS read-only
STATUS optional
DESCRIPTION
"Indicates if the PDL processing sub-system has made
marks on the current page and the source subsystem has
been idle for a device specific amount of time.
Additional information:
LaserJet 5Si will set this object to eTrue when a
personality has made marks on the current page, the personality timeout has
expired and no data is pending on another I/O. Once it is set to eTrue, more
data on the same I/O will cause this object to be set to eFalse, until the
above conditions are met again."
::= { status-pdl 2 }
pcl-resource-saving-memory-size OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS optional
DESCRIPTION
"Returns or changes the amount of resource saving memory
set aside to hold permanent soft PCL resources.
Additional information:
The value returned by this object is the amount of
Resource Saving memory currently dedicated to PCL, regardless of the value of
RESOURCE-SAVING.
For a PCL-only printer, the value of this object is zero. All memory is
dedicated to PCL, but it is not shown as such.
If PostScript is installed without a duplex unit, the default value of this
object is as follows:
Zero if <13M memory is installed.
Zero if 13M memory is installed and RESOURCE-SAVING=eOff.
409600 if 13M memory is installed and RESOURCE-SAVING=eOn.
409600 if 13M memory is installed and RESOURCE-SAVING=eAuto; plus 102400 for
each 1M over 13M memory installed.
If PostScript is installed with a duplex unit, the default value of this
object is as follows:
Zero if <24M memory is installed.
Zero if 24M memory is installed and RESOURCE-SAVING=eOff.
409600 if 24M memory is installed and RESOURCE-SAVING=eOn.
409600 if 24M memory is installed and RESOURCE-SAVING=eAuto; plus 102400 for
each 1M over 24M memory installed.
If RESOURCE-SAVING=eOn, this object can be used to set the amount of Resource
Saving memory currently dedicated to PCL. The values supported are zero (to
turn resource saving off for PCL) and 409600 through 409600 plus the value of
MAXIMUM-RESOURCE-SAVING-MEMORY, in increments of 102400.
If a value is received that is between 1 and 409599, it will be snapped to
409600 and a status of <noError> returned.
If an unsupported value greater than 409600 is received,
it will be snapped down to the nearest 102400 value
and a status of <noError> returned.
Attempting to set this object when RESOURCE-SAVING
is eAuto or eOff will cause a status of <genErr> to
be returned."
::= { pdl-pcl 2 }
pcl-total-page-count OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION
"Total number of PCL pages printed by the device.
Additional information:
In LaserJet 5Si the PCL page count is kept in
NVRAM however the NVRAM value is only updated every 10
pages. NOTE: The value returned by this OID will be
incremented every page but if power is lost between
NVRAM updates, up to 9 pages of the page count may be
lost. The page count counter will be reset to zero
after 16,777,215 (2^24-1) pages.
The page count is incremented when a sheet of media is pulled from an input
tray. A duplex printed sheet will cause this counter to be incremented by
two."
::= { pdl-pcl 5 }
pcl-default-font-height OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS optional
DESCRIPTION
"Returns or changes the default PCL height. Height is an
approximate measure of the body of the type in
centipoints. A centipoint is 1/7200 inch. Height
applies only to proportional fonts. Point size, in
points, can be converted to font height, in centipoints,
by multiplying the point size by 100. The POS indicates
the supported values. An unsupported value causes the
printer to use the closest supported value, causing the
printer to return <noError>.''Closest'' means the smallest absolute difference.
Additional information:
Setting to an unsupported value causes the
printer to
substitute in a snap value and to
return <noError> status.
The snap values are as follow:
<=400 snaps to 400
>=99975 snaps to 99975
Unsupported values in the range 400 to 99975 snaps
DOWN to the previous supported value
(i.e 25293 snaps to 25275 or 75038 snaps to 75025)."
::= { pdl-pcl 13 }
pcl-default-font-source OBJECT-TYPE
SYNTAX INTEGER {
eInternal(1),
ePermanentSoft(2),
eRomSimm1(10),
eRomSimm2(11),
eRomSimm3(12),
eRomSimm4(13)
}
ACCESS read-write
STATUS optional
DESCRIPTION
"Returns or changes the value of the default font source
variable in NVRAM."
::= { pdl-pcl 14 }
pcl-default-font-number OBJECT-TYPE
SYNTAX INTEGER(0..52)
ACCESS read-write
STATUS optional
DESCRIPTION
"Returns or changes the value of the default font number
variable in NVRAM. Writing an unsupported value causes
the printer to generate an
<badValue>."
::= { pdl-pcl 15 }
pcl-default-font-width OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS optional
DESCRIPTION
"Returns or changes the default PCL font width. Width is
expressed as the width of a character in centipoints. A
centipoint is 1/7200 inch. Width applies only to fixed
space fonts. Pitch, in character per inch, can be
converted to font width, in centipoints, by dividing
7200 by the pitch. The POS indicates the supported
values. An unsupported value causes the printer to use
the closest supported value, causing the printer to
return <noError>. ''Closest''
means the smallest absolute difference.
Additional information:
Setting to an unsupported value causes the
printer
to substitute in a snap value (listed below) and to
return <noError> status.
The snap values are as follow:
<=44 snaps to 44
>=9999 snaps to 9999"
::= { pdl-pcl 16 }
postscript-resource-saving-memory-size OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS optional
DESCRIPTION
"Returns or changes the amount of resource saving memory
set aside to hold permanent soft PostScript resources.
Additional information:
The value returned by this object is the amount of
Resource Saving memory currently dedicated to PostScript, regardless of the
value of RESOURCE-SAVING.
If PostScript is installed without a duplex unit, the default value of this
object is as follows:
Zero if <13M memory is installed.
Zero if 13M memory is installed and RESOURCE-SAVING=eOff.
409600 if 13M memory is installed and RESOURCE-SAVING=eOn.
409600 if 13M memory is installed and RESOURCE-SAVING=eAuto; plus 102400 for
each 1M over 13M memory installed.
If PostScript is installed with a duplex unit, the default value of this
object is as follows:
Zero if <24M memory is installed.
Zero if 24M memory is installed and RESOURCE-SAVING=eOff.
409600 if 24M memory is installed and RESOURCE-SAVING=eOn.
409600 if 24M memory is installed and RESOURCE-SAVING=eAuto; plus 102400 for
each 1M over 24M memory installed.
If RESOURCE-SAVING=eOn, this object can be used to set the amount of Resource
Saving memory currently dedicated to PostScript. The values supported are zero
(to turn resource saving off for PCL) and 409600 through 409600 plus
MAXIMUM-RESOURCE-SAVING-MEMORY, in increments of 102400. If a value is
received that is between 1 and 409599, it will be snapped to
409600 and a status of <noError> returned.
If an unsupported value greater than 409600 is received,
it will be snapped down to the nearest 102400 value
and a status of <noError> returned.
Attempting to set this object when RESOURCE-SAVING
is eAuto or eOff will cause a status of <genErr> to
be returned."
::= { pdl-postscript 2 }
postscript-total-page-count OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION
"Total number of PostScript pages printed by the device.
Additional information:
This object is only supported if PostScript
option is installed.
In LaserJet 5Si the count is kept in
NVRAM however the NVRAM value is only updated every 10
sheets. NOTE: The value returned by this OID will be
incremented every sheet but if power is lost between
NVRAM updates up to 9 sheets of the count may be
lost. The counter will be reset to zero
after 16,777,215 (2^24-1) pages. "
::= { pdl-postscript 5 }
postscript-print-errors OBJECT-TYPE
SYNTAX INTEGER {
eOff(1),
eOn(2)
}
ACCESS read-write
STATUS optional
DESCRIPTION
"Returns or changes the value of the print PostScript
errors setting. If eOn, PostScript prints an error page
showing the error encountered and the stack at the time
of the error.
Additional information:
This object is only supported if PostScript
option is installed."
::= { pdl-postscript 11 }
postscript-jam-recovery OBJECT-TYPE
SYNTAX INTEGER {
eOff(1),
eOn(2)
}
ACCESS read-write
STATUS optional
DESCRIPTION
"Returns or changes the PostScript jam recovery setting.
If eOn, then the device will reprint PostScript pages,
if those pages jam.
Additional information:
This object is only supported if PostScript
option is installed."
::= { pdl-postscript 12 }
pjl-password OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION
"Returns PJL password, if the password is not set (zero).
If the password is set, then attempting to retrieve the
password causes an <genErr> to occur
and will return the <NullValue>."
::= { pjl 1 }
override-media-name OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-write
STATUS optional
DESCRIPTION
"Sets a string identifying the media name that is to be
used in place of the currently requested media. The
substitution will continue until another media is
selected. If set to a named media that is not currently
available the requested media is not overridden.
Additional information:
When a request is received to print on a size and
type of media that is not currently available, this object contains the
desired media name as set by the print job. This object should be set to a
media name that is currently available in the printer.
If a paper mount request is not
pending, attempting to get or set this object will cause
<noSuchName> to be returned.
Setting this object to a string other than one of the MEDIAn-NAME objects
(MEDIA-NAMES-AVAILABLE is applied)
will cause a status of <badValue> to be returned."
::= { settings-prt-eng 2 }
override-media-size OBJECT-TYPE
SYNTAX INTEGER {
eUSExecutive(1),
eUSLetter(2),
eUSLegal(3),
eLedger(11),
eISOandJISA4(26),
eISOandJISA3(27),
eJISB5(45),
eJISB4(46),
eJapanesePostcardDouble(72),
eMonarch(80),
eCommercial10(81),
eInternationalDL(90),
eInternationalC5(91),
eInternationalB5(100),
eCustom(101)
}
ACCESS read-write
STATUS optional
DESCRIPTION
"Sets the media size that is to be used in place of the
currently requested media size.
Additional information:
When a request is received to print on a size and
type of media that is not currently available, this object contains the
desired size as set by the print job. This object should be set to a media
size that is currently available to the printer.
If a paper mount request is not
pending, attempting to get or set this object will cause
<noSuchName> to be returned."
::= { settings-prt-eng 3 }
print-density OBJECT-TYPE
SYNTAX INTEGER(1..5)
ACCESS read-write
STATUS optional
DESCRIPTION
"Returns or sets the print density setting. Print
density is the instantaneous amount of marking agent
applied to the paper while printing. A value of zero
has the lowest print density, yielding a lighter page.
A value of 10 has the highest print density, yielding a
darker page. Each POS should document what values in
the 0 to 10 range are supported.
Additional information:
When this value is written, the page pipeline
will be flushed (all pages being printed are
completed, no new ones are started), the new density
setting is set and printing resumes. The actual change
in print density may be gradual over several pages.
The supported values are 1
through 5. Setting to an unsupported value causes
the printer to substitute in a snap value
and to return
<noError> status.
The snap values are as follow:
<1 snaps to 1
>5 snaps to 5"
::= { settings-prt-eng 5 }
duplex-page-count OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION
"Total number of sheets of media that have been duplex
printed. A sheet is counted if it travels through the
duplex page path, regardless of whether or not marks are
made on the page. The POS will indicate if the value is
kept in NVRAM.
Additional information:
In LaserJet 5Si the count is kept in
NVRAM however the NVRAM value is only updated every 10
sheets. NOTE: The value returned by this OID will be
incremented every sheet but if power is lost between
NVRAM updates up to 9 sheets of the count may be
lost. The counter will be reset to zero
after 16,777,215 (2^24-1) pages. "
::= { status-prt-eng 22 }
mp-tray OBJECT-TYPE
SYNTAX INTEGER {
eCassette(2)
}
ACCESS read-only
STATUS optional
DESCRIPTION
"Returns or changes the value of the multi-purpose (MP)
tray configuration variable. The MP tray can be
configured to operate as an additional input tray
(eCassette), a manual feed slot (eManual), or in a
manner compatible with the LaserJet III manual feed slot
(eFirst). If configured for eFirst, if media is present
in the MP tray, that media is used (assuming the size
matches and the print job didn't specify another tray)
until the MP tray is empty.
Additional information:
LaserJet 5Si supports a slightly modified version of
Cassette mode. The difference is that media will be pulled from Tray 1 (the
MP tray) if there is a sheet present and it matches the needed size and type."
::= { settings-intray 5 }
tray4-phd OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION
"Provides the number of the Paper Handling Device that
contains this input tray."
::= { intray4 12 }
tray5-phd OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION
"Provides the number of the Paper Handling Device that
contains this input tray."
::= { intray5 12 }
overflow-bin OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS optional
DESCRIPTION
"Returns or sets the bin that will be used for additional
sheets of media when the current bin is full and
printing is allowed to continue.
Additional information:
If this object is set to zero, overflowing to another
bin is not allowed."
::= { settings-outbin 4 }
outbin1-override-mode OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS optional
DESCRIPTION
"Returns or sets the device behavior when this output bin
condition causes printing to stop.
cCancelJob - The device cancels the job.
cOutbinFullOverride - The device sends subsequent
media to the overflow bin.
cOutbinAttentionOverride - The device ignores the
attention condition and continues printing.
cBinderAttentionOverride - The device ignores the
binder attention condition and continues printing.
Additional information:
If cCancelJob is set, the current print job will
be cancelled regardless of other item settings.
If cOutbinFullOverride is set and this bin is the designated overflow bin
(OVERFLOW-BIN = 1), then the bit is ignored.
This object describes the action that is performed when the
JOB-OUTPUT-AUTO-CONTINUE-TIMEOUT expires. If no bits are set, no override
action is taken (the printer will continue to wait).
The action performed by the CONTINUE
object being set to eInitiateAction or the Select key being pressed on
the control panel may cause different actions.
See CONTINUE object
description for information on the actions that occur for those conditions."
::= { outbin1 9 }
outbin3-override-mode OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS optional
DESCRIPTION
"Returns or sets the device behavior when this output bin
condition causes printing to stop.
cCancelJob - The device cancels the job.
cOutbinFullOverride - The device sends subsequent
media to the overflow bin.
cOutbinAttentionOverride - The device ignores the
attention condition and continues printing.
cBinderAttentionOverride - The device ignores the
binder attention condition and continues printing.
Additional information:
If cCancelJob is set, the current print job will
be cancelled regardless of other item settings.
This object describes the action that is performed when the
JOB-OUTPUT-AUTO-CONTINUE-TIMEOUT expires. The action performed by the CONTINUE
object being set to eInitiateAction or the Select key being pressed on
the control panel may cause different actions.
See CONTINUE object
description for information on the actions that occur for those conditions"
::= { outbin3 9 }
outbin3-phd OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION
"Provides the number of the Paper Handling Device that
contains this output bin."
::= { outbin3 11 }
outbin4-override-mode OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS optional
DESCRIPTION
"Returns or sets the device behavior when this output bin
condition causes printing to stop.
cCancelJob - The device cancels the job.
cOutbinFullOverride - The device sends subsequent
media to the overflow bin.
cOutbinAttentionOverride - The device ignores the
attention condition and continues printing.
cBinderAttentionOverride - The device ignores the
binder attention condition and continues printing.
Additional information:
See OUTBIN3-OVERRIDE-MODE."
::= { outbin4 9 }
outbin4-phd OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION
"Provides the number of the Paper Handling Device that
contains this output bin."
::= { outbin4 11 }
outbin5-override-mode OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS optional
DESCRIPTION
"Returns or sets the device behavior when this output bin
condition causes printing to stop.
cCancelJob - The device cancels the job.
cOutbinFullOverride - The device sends subsequent
media to the overflow bin.
cOutbinAttentionOverride - The device ignores the
attention condition and continues printing.
cBinderAttentionOverride - The device ignores the
binder attention condition and continues printing.
Additional information:
See OUTBIN3-OVERRIDE-MODE."
::= { outbin5 9 }
outbin5-phd OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION
"Provides the number of the Paper Handling Device that
contains this output bin."
::= { outbin5 11 }
outbin6-override-mode OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS optional
DESCRIPTION
"Returns or sets the device behavior when this output bin
condition causes printing to stop.
cCancelJob - The device cancels the job.
cOutbinFullOverride - The device sends subsequent
media to the overflow bin.
cOutbinAttentionOverride - The device ignores the
attention condition and continues printing.
cBinderAttentionOverride - The device ignores the
binder attention condition and continues printing.
Additional information:
See OUTBIN3-OVERRIDE-MODE."
::= { outbin6 9 }
outbin6-phd OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION
"Provides the number of the Paper Handling Device that
contains this output bin."
::= { outbin6 11 }
outbin7-override-mode OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS optional
DESCRIPTION
"Returns or sets the device behavior when this output bin
condition causes printing to stop.
cCancelJob - The device cancels the job.
cOutbinFullOverride - The device sends subsequent
media to the overflow bin.
cOutbinAttentionOverride - The device ignores the
attention condition and continues printing.
cBinderAttentionOverride - The device ignores the
binder attention condition and continues printing.
Additional information:
See OUTBIN3-OVERRIDE-MODE."
::= { outbin7 9 }
outbin7-phd OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION
"Provides the number of the Paper Handling Device that
contains this output bin."
::= { outbin7 11 }
outbin8-override-mode OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS optional
DESCRIPTION
"Returns or sets the device behavior when this output bin
condition causes printing to stop.
cCancelJob - The device cancels the job.
cOutbinFullOverride - The device sends subsequent
media to the overflow bin.
cOutbinAttentionOverride - The device ignores the
attention condition and continues printing.
cBinderAttentionOverride - The device ignores the
binder attention condition and continues printing.
Additional information:
See OUTBIN3-OVERRIDE-MODE."
::= { outbin8 9 }
outbin8-phd OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION
"Provides the number of the Paper Handling Device that
contains this output bin."
::= { outbin8 11 }
outbin9-override-mode OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS optional
DESCRIPTION
"Returns or sets the device behavior when this output bin
condition causes printing to stop.
cCancelJob - The device cancels the job.
cOutbinFullOverride - The device sends subsequent
media to the overflow bin.
cOutbinAttentionOverride - The device ignores the
attention condition and continues printing.
cBinderAttentionOverride - The device ignores the
binder attention condition and continues printing.
Additional information:
See OUTBIN3-OVERRIDE-MODE."
::= { outbin9 9 }
outbin9-maximum-binding OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION
"The maximum number of sheets of 20 pound paper that can
be bound by the binding device that serves this output
bin. If a job exceeds this number and the job has
requested binding, cBindingError will be set in NOT-
READY-DESTINATION-PRINT-ENGINE.
Additional information:
This value indicates the maximum number of pages that
can be bound by the Outbin. For LaserJet 5Si Mopier, the stapler can
bind/staple 20 sheets."
::= { outbin9 10 }
outbin9-phd OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION
"Provides the number of the Paper Handling Device that
contains this output bin."
::= { outbin9 11 }
outbin10-override-mode OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS optional
DESCRIPTION
"Returns or sets the device behavior when this output bin
condition causes printing to stop.
cCancelJob - The device cancels the job.
cOutbinFullOverride - The device sends subsequent
media to the overflow bin.
cOutbinAttentionOverride - The device ignores the
attention condition and continues printing.
cBinderAttentionOverride - The device ignores the
binder attention condition and continues printing.
Additional information:
See OUTBIN3-OVERRIDE-MODE."
::= { outbin10 9 }
outbin10-phd OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION
"Provides the number of the Paper Handling Device that
contains this output bin."
::= { outbin10 11 }
outbin11-override-mode OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS optional
DESCRIPTION
"Returns or sets the device behavior when this output bin
condition causes printing to stop.
cCancelJob - The device cancels the job.
cOutbinFullOverride - The device sends subsequent
media to the overflow bin.
cOutbinAttentionOverride - The device ignores the
attention condition and continues printing.
cBinderAttentionOverride - The device ignores the
binder attention condition and continues printing.
Additional information:
See OUTBIN9-OVERRIDE-MODE."
::= { outbin11 9 }
outbin11-phd OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION
"Provides the number of the Paper Handling Device that
contains this output bin."
::= { outbin11 11 }
low-marking-agent-processing OBJECT-TYPE
SYNTAX INTEGER {
eStop(1),
eCont(2)
}
ACCESS read-write
STATUS optional
DESCRIPTION
"Returns or changes how the device processes a low
marking agent event. If eCont, then the device
continues to print. If eStop, then the device stops
until a continue event occurs."
::= { settings-marking-agent 3 }
default-ret OBJECT-TYPE
SYNTAX INTEGER {
eOff(1),
eLight(2),
eMedium(3),
eDark(4)
}
ACCESS read-write
STATUS optional
DESCRIPTION
"Returns or changes the Resolution Enhancement Technology
setting. Devices that only support eOff and on should
map all other values to on and always return the same
non-eOff value to indicate on. The list of supported
values should be documented in the device POS.
Additional information:
Setting this object to eLight or eDark will cause
the object to be set to eMedium and a status of
<noError> will be returned."
::= { imaging 5 }
default-print-quality OBJECT-TYPE
SYNTAX INTEGER(0..100)
ACCESS read-write
STATUS optional
DESCRIPTION
"Returns or sets the default print quality. A value of
zero has the lowest print quality. A value of 100 has
the highest print quality. Each POS should document
what values in the 0 to 100 range are supported.
Additional information:
In LaserJet 5Si, the supported values are 0
and 100. A value of zero corresponds to ECONOMODE=ON,
minimizing the toner
used. A value of 100 corresponds to ECONOMODE=OFF.
Setting
to an unsupported value outside of the 0 to 100 range
causes the printer to return
<badValue> status. Setting
to an unsupported value inside of the 0 to 100 range
causes the printer to substitute in a snap value
(listed below) and to return
<noError> status.
The snap values are as follow:
0 to 50 snap to 0
51 to 100 snap to 100"
::= { imaging 7 }
phd2-device-specific-command OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS write-only
STATUS optional
DESCRIPTION
"This object is used to send device-specific data to the
paper handling device. The meaning of the device-
specific command is dependent on the paper handling
device and must be specified in the POS.
If the paper handling device does not accept the
command, then an <badValue> will
be returned. If the device accepts the command, it may
still be processing the command after the response has
been returned. Depending on the device, the application
may need to query PHDx-DEVICE-MEMORY to see when the
command has completed.
Additional information:
The device-specific binary strings that may be sent to the
paper handling device. For LaserJet 5Si Mopier PHD2, the data is meaningless."
::= { ph2 2 }
phd2-device-memory OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(16))
ACCESS read-only
STATUS optional
DESCRIPTION
"This object is used to read the current values stored in
shared memory available from the paper handling device.
Additional information:
This object returns the 16 bytes of NVRAM data that the
formatter saves for the paper handling device. For the HCI,
the data is meaningless."
::= { ph2 4 }
phd3-device-specific-command OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS write-only
STATUS optional
DESCRIPTION
"This object is used to send device-specific data to the
paper handling device. The meaning of the device-
specific command is dependent on the paper handling
device and must be specified in the POS.
If the paper handling device does not accept the
command, then an <badValue> will
be returned. If the device accepts the command, it may
still be processing the command after the response has
been returned. Depending on the device, the application
may need to query PHDx-DEVICE-MEMORY to see when the
command has completed.
Additional information:
For Tlatoani, the device-specific binary
strings that may be sent to the paper handling device are described
below.
The value returned in reponse to the set request is the HCO mode (note that
it is the current mode, which is not necessarily the same as the mode just
set). The format
of the response is the same as the command format, including the command
byte.
The general format of the binary string is:
<command> <option> <parameters>. The current HCO implementation does not
require any <parameters>.
BYTE 1 is Command {Valid value: 1 .. 2}
1 = Set HCO Mode
2 = Return HCO Mode
BYTE 2 is Set HCO Mode Option {Valid values: 1 .. 4}
1 = Stacker
2 = Separator
3 = Collator <<Not used for Tlatoani>>
4 = Mailbox
Mailbox 1 is the TOP mailbox.
Example for setting the mode:
BYTE number:
1 2
1 1 Set mode to Stacker.
1 2 Set mode to Separator.
1 4 Set mode to Mailbox.
Example for getting the current mode:
BYTE number:
1 2
2 0 Command to return the mode.
2 1 Current mode is Stacker.
2 2 Current mode is Separator.
2 4 Current mode is Mailbox."
::= { ph3 2 }
phd3-device-memory OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(16))
ACCESS read-only
STATUS optional
DESCRIPTION
"This object is used to read the current values stored in
shared memory available from the paper handling device.
Additional information:
This object returns the 16 bytes of NVRAM data that the
formatter saves for the paper handling device. For Tlatoani,
the data includes the current mode of the device. The format
is as follows:
Byte 1: Always 1
Byte 2: HCO Mode (see PHD3-DEVICE-SPECIFIC-COMMAND)
Byte 3: Sum of bytes 1 and 2"
::= { ph3 4 }
phd4-device-specific-command OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS write-only
STATUS optional
DESCRIPTION
"This object is used to send device-specific data to the
paper handling device. The meaning of the device-
specific command is dependent on the paper handling
device and must be specified in the POS.
If the paper handling device does not accept the
command, then an <badValue> will
be returned. If the device accepts the command, it may
still be processing the command after the response has
been returned. Depending on the device, the application
may need to query PHDx-DEVICE-MEMORY to see when the
command has completed.
Additional information:
The device-specific binary strings that may be sent to the
paper handling device. "
::= { ph4 2 }
phd4-device-memory OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(16))
ACCESS read-only
STATUS optional
DESCRIPTION
"This object is used to read the current values stored in
shared memory available from the paper handling device.
Additional information:
This object returns the 16 bytes of NVRAM data that the
formatter saves for the paper handling device. For the STAPLER,
the data is meaningless."
::= { ph4 4 }
media-names-available OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS optional
DESCRIPTION
"The value of this object controls which of the MEDIAx-
NAME objects are supported. If a bit is set to zero,
then attempting to get or set the corresponding MEDIAx-
NAME objects will return
<noSuchName>.
Additional information:
Setting a bit to one will cause the corresponding
MEDIAn- objects to be available (attempting to access an unavailable object
will return <noSuchName>).
MEDIA1- objects are always present in LaserJet 5Si, as this is the default media.
If this object is
set to a value that does not include cMediaName1Available, that bit will be
set and a status of <noError> will be returned."
::= { settings-print-media 1 }
media1-name OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS optional
DESCRIPTION
"Media 1 name.
Additional information:
The symbol set for this string is Roman-8."
::= { media1 1 }
media1-short-name OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS optional
DESCRIPTION
"Length restricted version of the media name 1. The
length restriction is required to allow the media name
to be displayed on the device's control panel. The
device POS must state the maximum number of characters
allowed. If the device also has a limitation on what
characters in a character set can be used (e.g. only
uppercase characters allowed), the POS should also state
character restrictions."
::= { media1 2 }
media1-page-count OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION
"Number of sheets of media 1 that have been printed. The
device POS should state whether this value is lost
across a power cycle or kept in NVRAM.
Additional information:
In LaserJet 5Si the media page count saved in NVRAM after every 10
pages. The maximum value is 4,294,967,295 which will never be reached in
normal operation.
The page count is incremented when a sheet of media is pulled from an input
tray. A duplex printed sheet will cause this counter to be incremented by
one."
::= { media1 3 }
media2-name OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS optional
DESCRIPTION
"Media 2 name.
Additional information:
See MEDIA1-NAME."
::= { media2 1 }
media2-short-name OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS optional
DESCRIPTION
"Length restricted version of the media name 2. See
MEDIA1-SHORT-NAME for details."
::= { media2 2 }
media2-page-count OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION
"Number of sheets of media 2 that have been printed. See
MEDIA1-PAGE-COUNT for details.
Additional information:
See MEDIA1-PAGE-COUNT."
::= { media2 3 }
media3-name OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS optional
DESCRIPTION
"Media 3 name.
Additional information:
See MEDIA1-NAME."
::= { media3 1 }
media3-short-name OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS optional
DESCRIPTION
"Length restricted version of the media name 3. See
MEDIA1-SHORT-NAME for details."
::= { media3 2 }
media3-page-count OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION
"Number of sheets of media 3 that have been printed. See
MEDIA1-PAGE-COUNT for details.
Additional information:
See MEDIA1-PAGE-COUNT."
::= { media3 3 }
media4-name OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS optional
DESCRIPTION
"Media 4 name.
Additional information:
See MEDIA1-NAME."
::= { media4 1 }
media4-short-name OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS optional
DESCRIPTION
"Length restricted version of the media name 4. See
MEDIA1-SHORT-NAME for details."
::= { media4 2 }
media4-page-count OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION
"Number of sheets of media 4 that have been printed. See
MEDIA1-PAGE-COUNT for details.
Additional information:
See MEDIA1-PAGE-COUNT."
::= { media4 3 }
media5-name OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS optional
DESCRIPTION
"Media 5 name.
Additional information:
See MEDIA1-NAME."
::= { media5 1 }
media5-short-name OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS optional
DESCRIPTION
"Length restricted version of the media name 5. See
MEDIA1-SHORT-NAME for details."
::= { media5 2 }
media5-page-count OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION
"Number of sheets of media 5 that have been printed. See
MEDIA1-PAGE-COUNT for details.
Additional information:
See MEDIA1-PAGE-COUNT."
::= { media5 3 }
media6-name OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS optional
DESCRIPTION
"Media 6 name.
Additional information:
See MEDIA1-NAME."
::= { media6 1 }
media6-short-name OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS optional
DESCRIPTION
"Length restricted version of the media name 6. See
MEDIA1-SHORT-NAME for details."
::= { media6 2 }
media6-page-count OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION
"Number of sheets of media 6 that have been printed. See
MEDIA1-PAGE-COUNT for details.
Additional information:
See MEDIA1-PAGE-COUNT."
::= { media6 3 }
media7-name OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS optional
DESCRIPTION
"Media 7 name.
Additional information:
See MEDIA1-NAME."
::= { media7 1 }
media7-short-name OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS optional
DESCRIPTION
"Length restricted version of the media name 7. See
MEDIA1-SHORT-NAME for details."
::= { media7 2 }
media7-page-count OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION
"Number of sheets of media 7 that have been printed. See
MEDIA1-PAGE-COUNT for details.
Additional information:
See MEDIA1-PAGE-COUNT."
::= { media7 3 }
media8-name OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS optional
DESCRIPTION
"Media 8 name.
Additional information:
See MEDIA1-NAME."
::= { media8 1 }
media8-short-name OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS optional
DESCRIPTION
"Length restricted version of the media name 8. See
MEDIA1-SHORT-NAME for details."
::= { media8 2 }
media8-page-count OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION
"Number of sheets of media 8 that have been printed. See
MEDIA1-PAGE-COUNT for details.
Additional information:
See MEDIA1-PAGE-COUNT."
::= { media8 3 }
media9-name OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS optional
DESCRIPTION
"Media 9 name.
Additional information:
See MEDIA1-NAME."
::= { media9 1 }
media9-short-name OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS optional
DESCRIPTION
"Length restricted version of the media name 9. See
MEDIA1-SHORT-NAME for details."
::= { media9 2 }
media9-page-count OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION
"Number of sheets of media 9 that have been printed. See
MEDIA1-PAGE-COUNT for details.
Additional information:
See MEDIA1-PAGE-COUNT."
::= { media9 3 }
media10-name OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS optional
DESCRIPTION
"Media 10 name.
Additional information:
See MEDIA1-NAME."
::= { media10 1 }
media10-short-name OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS optional
DESCRIPTION
"Length restricted version of the media name 10. See
MEDIA1-SHORT-NAME for details."
::= { media10 2 }
media10-page-count OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION
"Number of sheets of media 10 that have been printed.
See MEDIA1-PAGE-COUNT for details.
Additional information:
See MEDIA1-PAGE-COUNT."
::= { media10 3 }
media11-name OBJECT-TYPE
SYNTAX DisplayString (SIZE(1..24))
ACCESS read-write
STATUS optional
DESCRIPTION
"Media 11 name.
Additional information:
The maximum supported string length is 24
bytes. If the user entered string is too long,
the device will store the first 24 bytes and
return the <noError> status.
See CAUTION statement under Product Specific Use."
::= { media11 1 }
media11-short-name OBJECT-TYPE
SYNTAX DisplayString (SIZE(1..10))
ACCESS read-write
STATUS optional
DESCRIPTION
"Length restricted version of the media name 11. See
MEDIA1-SHORT-NAME for details.
Additional information:
The maximum supported string length is 10
characters. If the user entered string is too long,
the device will store the first 10 characters and will
return the <noError> status.
The characters must be in the range 20H to 7FH except 5C cannot be used. The
default symbol set is Roman-8 for English; additional
legal symbol sets are ISOLatin5, ISOLatin2 and Windows31J. Setting this
object with characters outside of the range or an illegal symbol set will
cause an error status of <badValue> to be returned."
::= { media11 2 }
media11-page-count OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION
"Number of sheets of media 11 that have been printed.
See MEDIA1-PAGE-COUNT for details.
Additional information:
See MEDIA1-PAGE-COUNT."
::= { media11 3 }
media12-name OBJECT-TYPE
SYNTAX DisplayString (SIZE(1..24))
ACCESS read-write
STATUS optional
DESCRIPTION
"Media 12 name.
Additional information:
See MEDIA11-NAME."
::= { media12 1 }
media12-short-name OBJECT-TYPE
SYNTAX DisplayString (SIZE(1..10))
ACCESS read-write
STATUS optional
DESCRIPTION
"Length restricted version of the media name 12. See
MEDIA1-SHORT-NAME for details.
Additional information:
See MEDIA11-SHORT-NAME."
::= { media12 2 }
media12-page-count OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION
"Number of sheets of media 12 that have been printed.
See MEDIA1-PAGE-COUNT for details.
Additional information:
See MEDIA11-PAGE-COUNT."
::= { media12 3 }
media13-name OBJECT-TYPE
SYNTAX DisplayString (SIZE(1..24))
ACCESS read-write
STATUS optional
DESCRIPTION
"Media 13 name.
Additional information:
See MEDIA11-NAME."
::= { media13 1 }
media13-short-name OBJECT-TYPE
SYNTAX DisplayString (SIZE(1..10))
ACCESS read-write
STATUS optional
DESCRIPTION
"Length restricted version of the media name 13. See
MEDIA1-SHORT-NAME for details.
Additional information:
See MEDIA11-SHORT-NAME."
::= { media13 2 }
media13-page-count OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION
"Number of sheets of media 13 that have been printed.
See MEDIA1-PAGE-COUNT for details.
Additional information:
See MEDIA11-PAGE-COUNT."
::= { media13 3 }
media14-name OBJECT-TYPE
SYNTAX DisplayString (SIZE(1..24))
ACCESS read-write
STATUS optional
DESCRIPTION
"Media 14 name.
Additional information:
See MEDIA11-NAME."
::= { media14 1 }
media14-short-name OBJECT-TYPE
SYNTAX DisplayString (SIZE(1..10))
ACCESS read-write
STATUS optional
DESCRIPTION
"Length restricted version of the media name 14. See
MEDIA1-SHORT-NAME for details.
Additional information:
See MEDIA11-SHORT-NAME."
::= { media14 2 }
media14-page-count OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION
"Number of sheets of media 14 that have been printed.
See MEDIA1-PAGE-COUNT for details.
Additional information:
See MEDIA11-PAGE-COUNT."
::= { media14 3 }
media15-name OBJECT-TYPE
SYNTAX DisplayString (SIZE(1..24))
ACCESS read-write
STATUS optional
DESCRIPTION
"Media 15 name.
Additional information:
See MEDIA11-NAME."
::= { media15 1 }
media15-short-name OBJECT-TYPE
SYNTAX DisplayString (SIZE(1..10))
ACCESS read-write
STATUS optional
DESCRIPTION
"Length restricted version of the media name 15. See
MEDIA1-SHORT-NAME for details.
Additional information:
See MEDIA11-SHORT-NAME."
::= { media15 2 }
media15-page-count OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION
"Number of sheets of media 15 that have been printed.
See MEDIA1-PAGE-COUNT for details.
Additional information:
See MEDIA11-PAGE-COUNT."
::= { media15 3 }
channel-bytes-sent OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION
"The low order 31 bits of the number of bytes sent from
the printer to the host on this logical channel."
::= { channel-entry 2 }
channel-bytes-received OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION
"The low order 31 bits of the number of bytes received by
the printer from the host on this logical channel."
::= { channel-entry 3 }
channel-io-errors OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION
"The low order 31 bits of the number of I/O errors which
have occured on this logical channel."
::= { channel-entry 4 }
channel-jobs-received OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION
"The low order 31 bits of the number of print jobs which
have been received on this logical channel."
::= { channel-entry 5 }
channel-mio OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION
"The number of the MIO card associated with this logical
channel. If this logical channel is not associated with
an MIO card a zero is returned. The value 1 is returned
if this logical channel is associated with an MIO card
in slot 1. The value 2 is returned if this logical
channel is associated with an MIO card in slot 2.
Additional information:
The value returned will be zero for channel one.
If an MIOA card is installed, channels 2..8 will
return a value of one or two and,
if an MIOB card is installed, 9-15 will return a
value of one or two, but not the same as channels
2..8. When two MIO cards are installed, the value
returned by any channel 2-15 may change after the
printer is power cycled."
::= { channel-entry 6 }
file-system-memory OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION
"The amount of memory, in bytes, used by the file system
to buffer file data.
Additional information:
Reports the amount of memory, in bytes,
reserved for use by the file system. Returns
<noSuchName> status if attempting
to access this object and there is no storage device
is installed."
::= { settings-file-system 1 }
file-system-max-open-files OBJECT-TYPE
SYNTAX INTEGER(32..512)
ACCESS read-write
STATUS optional
DESCRIPTION
"The number of open files allowed at one time. Opening a
file when the maximum number of files are currently open
will fail.
Additional information:
Indicates the number of open files a
personality (e.g. PCL or PostScript) is guaranteed to be
able to open before the file system runs out of file handles.
After writing this object, the printer
must be rebooted before the change takes effect.
Performing a cold reset sets this object
back to the factory default value. Returns
<noSuchName>
status if attempting to access this object and there
is no storage device is installed."
::= { settings-file-system 2 }
file-system-statistic-read-open OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION
"The number of times the file system has received
requests to open a file for reading. Opening a file for
both reading and writing will cause this value to
change. The POS should state if a power cycle causes
the counter is be reset to zero.
Additional information:
Reset to the factory default value after
a power cycle.
Returns <noSuchName>
status if attempting to access this object and there
is no storage device is installed."
::= { status-file-system 1 }
file-system-statistic-write-open OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION
"The number of times the file system has received
requests to open a file for writing. Opening a file for
both reading and writing will cause this value to
change. The POS should state if a power cycle causes
the counter is be reset to zero.
Additional information:
Reset to the factory default value after
a power cycle.
Returns <noSuchName>
status if attempting to access this object and there
is no storage device is installed."
::= { status-file-system 2 }
file-system-statistic-successful OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION
"A counter indicating the number of file system requests
that completed successfully. The POS should state if a
power cycle causes the counter is be reset to zero.
Additional information:
Reset to the factory default value after
a power cycle.
Returns <noSuchName>
status if attempting to access this object and there
is no storage device is installed."
::= { status-file-system 3 }
file-system-statistic-unsuccessful OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION
"A counter indicating the number of file system requests
that completed unsuccessfully. The POS should state if
a power cycle causes the counter is be reset to zero.
Additional information:
Reset to the factory default value after
a power cycle.
Returns <noSuchName>
status if attempting to access this object and there
is no storage device is installed."
::= { status-file-system 4 }
file-system-statistic-current-memory-usage OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION
"A value indicating the number of bytes of RAM currently
used by the file system firmware.
Additional information:
Reset to the factory default value after
a power cycle.
Returns <noSuchName>
status if attempting to access this object and there
is no storage device is installed."
::= { status-file-system 5 }
file-system-statistic-max-memory-usage OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION
"A value indicating the maximum number of bytes of RAM
used by the file system firmware. The POS should state
if the value is reset to zero after a power cycle.
Additional information:
Reset to the factory default value after
a power cycle.
Returns <noSuchName>
status if attempting to access this object and there
is no storage device is installed."
::= { status-file-system 6 }
file-system2-initialize-volume OBJECT-TYPE
SYNTAX INTEGER {
eInitializing(2)
}
ACCESS write-only
STATUS optional
DESCRIPTION
"Setting this object to eInitializing causes file system
2 to be initialized. Reading this object indicates if
the file system is currently being initialized.
Additional information:
The hrDeviceIndex value for the mass storage
device is the same value that is used to index into the
FILE-SYSTEM sub-tree. Since this product only supports
one mass storage device, and since the hrDeviceIndex
for the mass storage device will be 2 if the mass storage device is
installed, the FILE-SYSTEM2-INITIALIZE-VOLUME object
will be the object that allows the mass storage device to be
initialized."
::= { file-system2 6 }
mass-storage-resource-change-counter OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION
"A counter which changes when a mass storage based
resource has been added or deleted.
Additional information:
The value of this counter changes
each time the MASS-STORAGE-RESOURCE-CHANGED object
is set to eTrue. The value also changes when the
mass storage device is initialized. However, the value does not
change when a mass storage device is removed and a different
mass storage device is installed. Performing a cold reset sets
this object back to the factory default value.
Returns <noSuchName>
status if attempting to access this object and there
is no storage device is installed."
::= { mass-storage-resources 1 }
mass-storage-resource-changed OBJECT-TYPE
SYNTAX INTEGER {
eTrue(2)
}
ACCESS write-only
STATUS optional
DESCRIPTION
"Setting to eTrue causes MASS-STORAGE-RESOURCE-CHANGE-
COUNTER to be incremented.
Additional information:
Returns <noSuchName>
status if attempting to access this object and there
is no storage device is installed."
::= { mass-storage-resources 2 }
rpc-test-return-code OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS write-only
STATUS optional
DESCRIPTION
"This test object that will not be supported in any
released product. Setting this object allows the next
RPC call return code to be specified. The POS will
specify the binary format.
Additional information:
The format of the binary data is a one
of three formats. The first format is no binary
data, which indicates the next RPC reply should not
be modified. The other two formats are described in
RFC 1057 and encoded using XDR (i.e. the value is
the data used to instead of the actual RPC reply).
The second format is when reply_stat is MSG_ACCEPTED
and accept_stat is something other than SUCCESS.
The third format is when reply_stat is MSG_DENIED.
Notice that all RPC replies that do not contain any
'results' are supported."
::= { settings-rpc 1 }
rpc-bind-protocol-address OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS optional
DESCRIPTION
"Array of Berkeley sockets style protocol addresses used
to bind RPC to a communications protocol family.
Setting an instance of this array object to a zero
length binary value disables the transport protocol
indicated by that instance. All multi-bytes fields are
in network (or big-endian) order. Bytes 1 and 2
indicate the transport protocol. Some of the transport
protocol mapping information can be found in RFC 1010
Assigned Numbers. A list of interesting transport
protocol number mappings include:
Protocol | Number
---------+-------
UDP/IP | 17
IPX | 1000
Bytes 3 and 4 indicate the address family. The address
family uses the same mapping as the BSD sockets address
family. A list of interesting address family mappings
include:
Address Family | Number
---------------+-------
Internet | 2
NetWare | 6
The format the fifth and following bytes is dependent on
the address family. For the Internet address family,
bytes 5 and 6 contain the port number, bytes 7 through
10 contain the IP address, and the following eight bytes
are unused. For NetWare, bytes 5 through 8 are the
network number, bytes 9 through 14 are the node number,
and bytes 15 and 16 are the socket number.
Additional information:
The length of the binary value is zero
if the instance of an object in the rpc-bind-protocol-address
array is not in use. A side effect of the
implementation is initializing the mass storage device sets this object
back to the factory default value.
Returns <noSuchName>
status if attempting to access this object and there
is no storage device is installed."
::= { settings-rpc 2 }
rpc-statistic-successful OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION
"A counter indicating the number of RPC requests that
completed successfully (reply_data stat is SUCCESS).
The POS should state if a power cycle causes the counter
is be reset to zero.
Additional information:
Reset to the factory default value after
a power cycle.
Returns <noSuchName>
status if attempting to access this object and there
is no storage device is installed."
::= { status-rpc 1 }
rpc-statistic-unsuccessful OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION
"A counter indicating the number of RPC requests that
completed unsuccessfully.
The POS should state if a power cycle causes
the counter is be reset to zero.
Additional information:
Reset to the factory default value after
a power cycle.
Returns <noSuchName>
status if attempting to access this object and there
is no storage device is installed."
::= { status-rpc 2 }
rpc-bound-protocol-address OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-only
STATUS optional
DESCRIPTION
"An array of Berkeley sockets style protocol addresses
that the NFS service has been bound to successful. The
format is that same as the array of RPC-BIND-PROTOCOL-
ADDRESS of objects.
Additional information:
Returns <noSuchName>
status if attempting to access this object and there
is no storage device is installed."
::= { status-rpc 3 }
mount-test-return-code OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS write-only
STATUS optional
DESCRIPTION
"This test object that will not be supported in any
released product. Setting this object allows the next
mount call return code to be specified. The POS will
specify the binary format.
Additional information:
A one byte binary value. The
byte indicates what procedure is being effected by
this set.
value | function
------+------------------
1 | Mount will return an fhstatus of 0.
2 | Dump will return an empty table."
::= { settings-mount 1 }
nfs-server-memory OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION
"The amount of memory, in bytes, used by the Network File
System server to buffer file data.
Additional information:
Reports the amount of memory, in bytes,
reserved for use by the NFS server. A
side effect of the implementation is initializing
the mass storage device sets this object back to the factory
default value. Also includes the memory used by
other firmware components in addition to the NFS
server. Returns <noSuchName>
status if attempting to access this object and there
is no storage device is installed."
::= { settings-nfs-server 1 }
nfs-server-read-size OBJECT-TYPE
SYNTAX INTEGER(256..1500)
ACCESS read-write
STATUS optional
DESCRIPTION
"The maximum amount of data transferred in one NFS server
read data call.
Additional information:
A side effect of the
implementation is initializing the mass storage device sets this object
back to the factory default value.
Returns <noSuchName>
status if attempting to access this object and there
is no storage device is installed."
::= { settings-nfs-server 2 }
nfs-server-write-size OBJECT-TYPE
SYNTAX INTEGER(256..1500)
ACCESS read-write
STATUS optional
DESCRIPTION
"The maximum amount of data transferred in one NFS server
write data call.
Additional information:
A side effect of the
implementation is initializing the mass storage device sets this object
back to the factory default value.
Returns <noSuchName>
status if attempting to access this object and there
is no storage device is installed."
::= { settings-nfs-server 3 }
nfs-server-statistic-successful OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION
"A counter indicating the number of NFS requests that
completed without error. The POS should state if a
power cycle causes the counter is be reset to zero.
Additional information:
Reset to the factory default value after
a power cycle.
Returns <noSuchName>
status if attempting to access this object and there
is no storage device is installed."
::= { status-nfs-server 1 }
nfs-server-statistic-unsuccessful OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION
"A counter indicating the number of NFS requests that
completed with an NFS status other than NFS_OK (0). The
POS should state if a power cycle causes the counter is
be reset to zero.
Additional information:
Reset to the factory default value after
a power cycle.
Returns <noSuchName>
status if attempting to access this object and there
is no storage device is installed."
::= { status-nfs-server 2 }
nfs-server-statistic-current-memory-usage OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION
"A value indicating the number of bytes of RAM currently
used by the NFS firmware.
Additional information:
Reset to the factory default value after
a power cycle.
Returns <noSuchName>
status if attempting to access this object and there
is no storage device is installed."
::= { status-nfs-server 4 }
nfs-server-statistic-max-memory-usage OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION
"A value indicating the maximum number of bytes of RAM
used by the NFS firmware. The POS should state if the
value is reset to zero after a power cycle.
Additional information:
Reset to the factory default value after
a power cycle.
Returns <noSuchName>
status if attempting to access this object and there
is no storage device is installed."
::= { status-nfs-server 5 }
rpc-bind-test-return-code OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS write-only
STATUS optional
DESCRIPTION
"This test object that will not be supported in any
released product. Setting this object allows the next
RPC bind call return code to be specified. The POS will
specify the binary format.
Additional information:
A one byte value.
value | meaning
------+------------------
1 | Next GetPort or GetAddr will receive port 0
| (indicating the service is not supported).
2 | Next Dump will receive an empty table."
::= { settings-rpc-bind 1 }
rpc-bind-statistic-successful OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION
"A counter indicating the number of RPC bind (RPC program
number 100000, version 2) requests that completed
successfully. The POS should state if a power cycle
causes the counter is be reset to zero.
Additional information:
Reset to the factory default value after
a power cycle.
Returns <noSuchName>
status if attempting to access this object and there
is no storage device is installed."
::= { status-rpc-bind 1 }
rpc-bind-statistic-unsuccessful OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION
"A counter indicating the number of RPC bind (RPC program
number 100000, version 2) requests that completed
unsuccessfully. The POS should state if a power cycle
causes the counter is be reset to zero.
Additional information:
Reset to the factory default value after
a power cycle.
Returns <noSuchName>
status if attempting to access this object and there
is no storage device is installed."
::= { status-rpc-bind 2 }
xip-statistic-processed OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION
"A counter indicating the number of XIP requests that
were processed. The POS should state if a power cycle
causes the counter is be reset to zero.
Additional information:
The number of XIP datagrams that have
been received by the XIP service. Reset to the
factory default value after a power cycle. Returns
<noSuchName> status if attempting
to access this object and there is no storage device
is installed."
::= { status-xip 1 }
xip-statistic-data-in-dropped OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION
"A counter indicating the number of XIP data in datagrams
that were dropped (typically due to the printer being
flooded with XIP requests ). The POS should state if a
power cycle causes the counter is be reset to zero.
Additional information:
Reset to the factory default value after
a power cycle.
Returns <noSuchName>
status if attempting to access this object and there
is no storage device is installed."
::= { status-xip 2 }
disk-storage-block-driver2-test-return-code OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS write-only
STATUS optional
DESCRIPTION
"This test object will not be supported in any released
product. Setting this object allows the next call to
the mass storage block driver 2 to return the specified
code. The POS will specify the binary format.
Additional information:
The hrDeviceIndex value for the mass storage
device is the same value that is used to index into the
DISK-STORAGE-BLOCK-DRIVERS sub-tree. Since this product
only supports one mass storage device, the hrDeviceIndex
for the mass storage device will be 2 if the mass storage device is
installed. The value is a two byte value. The value
of the first byte indicates the return code, as described
in the following table:
value | meaning
------+------------------
1 | After the next power cycle, indicate the
| mass storage device is not installed. Only affects the
| printer state after the next power cycle.
2 | After the next power cycle, indicate the
| mass storage device is not initialized. Changes the
| contents of the mass storage device so the mass storage device becomes
| uninitialized.
3 | After the next power cycle, indicate the
| mass storage device is defective. Only affects the
| printer state after the next power cycle.
4 | Cause the specified call to the read block
| routine to indicate read failure.
5 | Cause the specified call to the write block
| routine to indicate write failure.
6 | After the next power cycle, indicate the
| mass storage device failed the power-on self-test, but
| completed the initialization sequence
| successfully. Only affects the
| printer state after the next power cycle.
7 | Cause the driver to behave, after the next power
| cycle, as if the mass storage device had the serial number
| 'SN00000000'. This is a one-shot effect and the
| driver reverts to normal behavior if the printer
| is power cycled a second time.
The second byte indicates on which call to the specified
block driver the failure will start to occur.
If the value of the first bytes is four or five, then the
value of the second byte in indicates which call to the
specified block driver routine will fail. A value of one
means the first call will fail. A value of two means the
second call will fail, and so on. If the value of the
first byte is one, two, three, six, or seven, then the
value of the second byte is ignored. Writing this object
causes any previous write to this object to be invalidated."
::= { settings-msbd2 1 }
hrmemorysize OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The amount of physical main memory contained by
the host.
Additional information:
The unit of measure for this object is 1024 bytes.
The default value assumes the base printer with no
additional memory."
::= { hrStorage 2 }
hrstorageindex OBJECT-TYPE
SYNTAX INTEGER(1..2147483647)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"A unique value for each logical storage area
contained by the host."
::= { hrStorageEntry 1 }
hrstoragetype OBJECT-TYPE
SYNTAX OBJECT IDENTIFIER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The type of storage represented by this entry."
::= { hrStorageEntry 2 }
hrstoragedescr OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-only
STATUS mandatory
DESCRIPTION
"A description of the type and instance of the
storage described by this entry.
Additional information:
This object is not localized."
::= { hrStorageEntry 3 }
hrstorageallocationunits OBJECT-TYPE
SYNTAX INTEGER(1..2147483647)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The size, in bytes, of the data objects allocated
from this pool. If this entry is monitoring
sectors, blocks, buffers, or packets, for example,
this number will commonly be greater than one.
Otherwise this number will typically be one.
Additional information:
Unit is one byte."
::= { hrStorageEntry 4 }
hrstoragesize OBJECT-TYPE
SYNTAX INTEGER(0..2147483647)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The size of the storage represented by this entry,
in units of hrStorageAllocationUnits.
Additional information:
Total formatter RAM."
::= { hrStorageEntry 5 }
hrstorageused OBJECT-TYPE
SYNTAX INTEGER(0..2147483647)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The amount of the storage represented by this
entry that is allocated, in units of
hrStorageAllocationUnits.
Additional information:
This object should not be used when creating a print
job for the device because the amount of memory in use will
likely be different when the printer processes the print job."
::= { hrStorageEntry 6 }
hrstorageallocationfailures OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of requests for storage represented by
this entry that could not be honored due to not
enough storage. It should be noted that as this
object has a SYNTAX of Counter, that it does not
have a defined initial value. However, it is
recommended that this object be initialized to
zero.
Additional information:
This object is set to zero at power on and when any
reset is done via prtGeneralReset.
This object is incremented whenever the printer is
short on memory."
::= { hrStorageEntry 7 }
hrdeviceindex OBJECT-TYPE
SYNTAX INTEGER(1..2147483647)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"A unique value for each device contained by the
host. The value for each device must remain
constant at least from one re-initialization of the
agent to the next re-initialization.
Additional information:
The entry in the Device Table which
describes the printer. "
::= { hrDeviceEntry 1 }
hrdevicetype OBJECT-TYPE
SYNTAX OBJECT IDENTIFIER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"An indication of the type of device.
If this value is `hrDeviceProcessor { hrDeviceTypes
3 }' then an entry exists in the hrProcessorTable
which corresponds to this device.
If this value is `hrDeviceNetwork { hrDeviceTypes 4
}', then an entry exists in the hrNetworkTable
which corresponds to this device.
If this value is `hrDevicePrinter { hrDeviceTypes 5
}', then an entry exists in the hrPrinterTable
which corresponds to this device.
If this value is `hrDeviceDiskStorage {
hrDeviceTypes 6 }', then an entry exists in the
hrDiskStorageTable which corresponds to this
device."
::= { hrDeviceEntry 2 }
hrdevicedescr OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..64))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"A textual description of this device, including
the device's manufacturer and revision, and
optionally, its serial number.
Additional information:
This object is not localized."
::= { hrDeviceEntry 3 }
hrdeviceid OBJECT-TYPE
SYNTAX OBJECT IDENTIFIER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The product ID for this device.
Additional information:
The complete OID reported by this object is:
.1.3.6.1.4.1.11.2.3.9.1.2.1"
::= { hrDeviceEntry 4 }
hrdevicestatus OBJECT-TYPE
SYNTAX INTEGER {
eHrunning(2),
eHwarning(3),
eHdown(5)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The current operational state of the device
described by this row of the table. A value
unknown(1) indicates that the current state of the
device is unknown. running(2) indicates that the
device is up and running and that no unusual error
conditions are known. The warning(3) state
indicates that agent has been informed of an
unusual error condition by the operational software
(e.g., a disk device driver) but that the device is
still 'operational'. An example would be high
number of soft errors on a disk. A value of
testing(4), indicates that the device is not
available for use because it is in the testing
state. The state of down(5) is used only when the
agent has been informed that the device is not
available for any use.
Additional information:
The printer's condition is mapped as follows:
eHrunning -- Printer ready to print or is printing.
May be in power save mode.
eHwarning -- A condition exists that needs attention but it is
not currently preventing printing. A non-critical alert is
active.
eHtesting -- Printer is printing an internal page.
eHdown -- Printer is not printing due to an error condition. A
critical alert is active, human interaction is needed to bring the printer to
a ready state or the printer is offline."
::= { hrDeviceEntry 5 }
hrdeviceerrors OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of errors detected on this device. It
should be noted that as this object has a SYNTAX
of Counter, that it does not have a defined
initial value. However, it is recommended that
this object be initialized to zero.
Additional information:
This is the number of critical alerts that have been
entered into the alert table since the device was powered on.
The maximum value for this object is 2^32-1."
::= { hrDeviceEntry 6 }
hrprinterstatus OBJECT-TYPE
SYNTAX INTEGER {
eHother(1),
eHidle(3),
eHprinting(4),
eHwarmup(5)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The current status of this printer device. When
in the idle(1), printing(2), or warmup(3) state,
the corresponding hrDeviceStatus should be
running(2) or warning(3). When in the unknown
state, the corresponding hrDeviceStatus should be
unknown(1).
Additional information:
The printer's condition is mapped as follows:
eHidle -- The printer is not doing any of the items listed below
for eHprinting status.
eHprinting -- The printer is processing PJL or PDL data, waiting
for an error condition to be cleared, processing a control
panel request, waiting for the engine to become ready or
printing images.
eHwarmup -- If hrDeviceStatus is eHdown, then the printer is
currently offline but is resolving
the condition that caused it be offline it will be online
when it is ready to print. If hrDeviceStatus is eHrunning,
then the printer was in power save mode and is now becoming
ready to print."
::= { hrPrinterEntry 1 }
hrprinterdetectederrorstate OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This object represents any error conditions
detected by the printer. The error conditions are
encoded as bits in an octet string, with the
following definitions:
Condition Bit # hrDeviceStatus
lowPaper 0 warning(3)
noPaper 1 down(5)
lowToner 2 warning(3)
noToner 3 down(5)
doorOpen 4 down(5)
jammed 5 down(5)
offline 6 down(5)
serviceRequested 7 warning(3)
If multiple conditions are currently detected and
the hrDeviceStatus would not otherwise be
unknown(1) or testing(4), the hrDeviceStatus shall
correspond to the worst state of those indicated,
where down(5) is worse than warning(3) which is
worse than running(2).
Bits are numbered starting with the most
significant bit of the first byte being bit 0, the
least significant bit of the first byte being bit
7, the most significant bit of the second byte
being bit 8, and so on. A one bit encodes that
the condition was detected, while a zero bit
encodes that the condition was not detected.
This object is useful for alerting an operator to
specific warning or error conditions that may
occur, especially those requiring human
intervention.
Additional information:
LaserJet 5Si reports error conditions as follows:
lowPaper -- A tray is empty, but the media to be loaded is not
currently needed.
hrDeviceStatus = eHwarning;
hrPrinterStatus = eHidle or eHprinting;
a non-critical alert is active.
noPaper -- A tray is empty and must be filled for printing to
continue.
hrDeviceStatus = eHdown;
hrPrinterStatus = eHother;
a non-critical alert is active.
lowToner -- A toner low condition has been detected.
hrDeviceStatus = eHwarning;
hrPrinterStatus = eHidle or eHprinting;
a non-critical alert is active.
noToner -- LaserJet 5Si does not report this condition.
doorOpen -- A door is open.
hrDeviceStatus = eHdown;
hrPrinterStatus = eHother;
a non-critical alert is active.
jammed -- A jam condition is preventing printing.
hrDeviceStatus = eHdown;
hrPrinterStatus = eHother;
a non-critical alert is active.
offline -- Printer is offline.
hrDeviceStatus = eHdown;
hrPrinterStatus = eHother;
a non-critical alert is active.
serviceRequested -- Any status or error condition not listed
above. If the condition prevents printing, the 'offline'
bit is also set and its hrDeviceStatus and hrPrinterStatus
would prevail.
hrDeviceStatus = eHwarning;
hrPrinterStatus = eHidle or eHprinting;
a non-critical alert is active."
::= { hrPrinterEntry 2 }
prtgeneralconfigchanges OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION
"Counts configuration changes that change the capabilities of
a printer, such as the addition/deletion of input/output bins,
the addition/deletion of interpreters, or changes in media
size. Such changes will often affect the capability of the
printer to service certain types of print jobs.
Management applications may cache infrequently changed
configuration information about sub-units on the printer.
This object should be incremented whenever the agent wishes
such applications to invalidate that cache and re-download
all of this configuration information, thereby signalling a
change in the printer's configuration.
For example, if an input tray that contained paper of
different dimensions was added, this counter would be
incremented.
As an additional example, this counter would not be
incremented when an input tray is removed or the level of an
input device changes.
Additional information:
This is a 32 bit counter (unsigned). When it reaches
its maximum value, it will roll to zero.
This object is stored in NVRAM."
::= { prtGeneralEntry 1 }
prtgeneralcurrentlocalization OBJECT-TYPE
SYNTAX INTEGER(1..14)
ACCESS read-write
STATUS optional
DESCRIPTION
"The value of the prtLocalizationIndex corresponding to the
current language, country, and character set to be used for
localized string values that are identified as being dependent
on the value of this object. Note that this object does not
apply to localized strings in the prtConsole group or any
object that is not identified as above.
Additional information:
The value of this object is saved in NVRAM."
::= { prtGeneralEntry 2 }
prtgeneralreset OBJECT-TYPE
SYNTAX INTEGER {
ePnotResetting(3),
ePpowerCycleReset(4),
ePresetToNVRAM(5),
ePresetToFactoryDefaults(6)
}
ACCESS read-write
STATUS optional
DESCRIPTION
"Setting this value to `powerCycleReset', `resetToNVRAM', or
`resetToFactoryDefaults' will result in the resetting of the
printer. When read, this object will always have the value
`notResetting(3)', and a SET of the value `notResetting' shall
have no effect on the printer. Some of the defined values are
optional. However, every implementation must support at least
the values `notResetting' and resetToNVRAM'.
Additional information:
All resets follow the same sequence of events except that a
a value of ePresetToFactoryDefaults first makes a call to reset the NVRAM to
factory defaults. Then, the following sequence of events occur:
1. A 1 second delay is initiated while a reply is returned to the requestor
indicating OK. The printer waits for the second to elapse.
2. The printer goes off-line.
3. The control panel is disabled.
4. The paper path is flushed.
5. The printer is reset per the request. The printer will respond to PML
requests up to this point in time.
Setting this object to ePpowerCycleReset causes LaserJet 5Si to perform its power
on initialization routines. I/O cards are reset (NVRAM on the cards is not
changed; all I/O buffers are flushed).
The tests normally run at power on time are executed.
Setting this object to ePresetToNVRAM causes the printer to reset itself to
its power on state without doing its normal power on testing. The I/O cards
are not reset and I/O buffers remain intact.
Setting this object to ePresetToFactoryDefaults causes the same action as a
Cold Reset operation performed at the control panel (except power on testing
is not performed).
The I/O cards
are not reset and I/O buffers remain intact."
::= { prtGeneralEntry 3 }
prtcoverdescription OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..255))
ACCESS read-only
STATUS optional
DESCRIPTION
"The manufacturer provided cover sub-mechanism name in the
localization specified by prtGeneralCurrentLocalization."
::= { prtCoverEntry 2 }
prtcoverstatus OBJECT-TYPE
SYNTAX INTEGER {
ePdoorOpen(3),
ePdoorClosed(4)
}
ACCESS read-only
STATUS optional
DESCRIPTION
"The status of this cover sub-unit.
Additional information:
LaserJet 5Si detects a door open condition only when
printing."
::= { prtCoverEntry 3 }
prtlocalizationlanguage OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..2))
ACCESS read-only
STATUS optional
DESCRIPTION
"A two character language code from ISO 639. Examples EN, GB,
CA, FR, DE.
Additional information:
The languages supported by LaserJet 5Si are English,
French, German, Italian, Spanish, Swedish, Danish, Norwegian, Dutch, Finnish,
Portuguese, Turkish, Polish and Japanese."
::= { prtLocalizationEntry 2 }
prtlocalizationcountry OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..2))
ACCESS read-only
STATUS optional
DESCRIPTION
"A two character country code from ISO 3166, a blank string
(two space characters) shall indicate that the country is
not defined. Examples: US, FR, DE, ...
Additional information:
The languages supported by LaserJet 5Si (and corresponding
country) are English (United States), French (France), German (Germany),
Italian (Italy), Spanish (Spain), Swedish (Sweden), Danish (Denmark),
Norwegian (Norway), Dutch (Netherlands), Finnish (Finland), Portuguese
(Portugal), Turkish (Turkey), Polish (Poland) and Japanese (Japan)."
::= { prtLocalizationEntry 3 }
prtlocalizationcharacterset OBJECT-TYPE
SYNTAX INTEGER {
ePcsHPRoman8(2004),
ePcsISOLatin5(12),
ePcsISOLatin2(5),
ePcsWindows31J(2024)
}
ACCESS read-only
STATUS optional
DESCRIPTION
"The coded character set used for this localization."
::= { prtLocalizationEntry 4 }
prtstoragerefindex OBJECT-TYPE
SYNTAX INTEGER(0..65535)
ACCESS read-only
STATUS optional
DESCRIPTION
"The value of the hrDeviceIndex of the printer device that this
storageEntry is associated with."
::= { prtStorageRefEntry 2 }
prtdevicerefindex OBJECT-TYPE
SYNTAX INTEGER(0..65535)
ACCESS read-only
STATUS optional
DESCRIPTION
"The value of the hrDeviceIndex of the printer device that this
deviceEntry is associated with."
::= { prtDeviceRefEntry 2 }
prtgeneralcurrentoperator OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..32))
ACCESS read-write
STATUS optional
DESCRIPTION
"The name of the current human operator responsible for
operating this printer. It is suggested that this string
include information that would enable other humans to reach
the operator, such as a phone number.
Additional information:
The maximum
supported string length is 32 characters. If the user
entered string is too long, the device will store as
much as possible and will return the
<noError> status.
This object is saved in NVRAM."
::= { prtGeneralEntry 4 }
prtgeneralserviceperson OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..32))
ACCESS read-write
STATUS optional
DESCRIPTION
"The name of the last human responsible for servicing
this printer. It is suggested that this string
include information that would enable other humans to reach
the service person, such as a phone number.
Additional information:
The maximum
supported string length is 32 characters. If the user
entered string is too long, the device will store as
much as possible and will return the
<noError> status.
This object is saved in NVRAM."
::= { prtGeneralEntry 5 }
prtinputdefaultindex OBJECT-TYPE
SYNTAX INTEGER(1..65535)
ACCESS read-only
STATUS optional
DESCRIPTION
"The value of prtInputIndex corresponding to the default input
sub-unit: that is, this object selects the default source of
input media.
Additional information:
The default input tray is determined by the printer
based on DEFAULT-MEDIA-SIZE and DEFAULT-MEDIA-NAME. If multiple trays have
qualifying media, tray 1 is selected first, then the non-empty tray with the
highest capacity is selected; trays of equal capacity are selected by lower
tray number.
Trays 1-3 refer to the printer's trays that are so labeled. Tray 4 is the
envelope feeder, which may or may not be present. Tray 5 is the first tray of
the first external input paper handling device."
::= { prtGeneralEntry 6 }
prtinputtype OBJECT-TYPE
SYNTAX INTEGER {
ePother(1),
ePunknown(2),
ePsheetFeedAutoRemovableTray(3),
ePsheetFeedAutoNonRemovableTray(4),
ePsheetFeedManual(5),
ePcontinuousRoll(6),
ePcontinuousFanFold(7)
}
ACCESS read-only
STATUS optional
DESCRIPTION
"The type of technology (discriminated primarily according to
feeder mechanism type) employed by the input sub-unit. Note,
the Optional Input Class provides for a descriptor field to
further qualify the other choice.
Additional information:
Tray 1 is the right side tray and is always present.
Tray 1 can operate in manual feed mode but is
typically treated as a normal input source. Therefore,
its type is ePsheetFeedAutoNonRemovableTray.
Trays 2 and 3 are the drawers and, although they are
usually not removed from the printer, the printer
cannot distinguish the open and removed conditions.
Therefore, when they are open, they are considered to
be removed and, for this object, they are considered
to be of type ePsheetFeedAutoRemovableTray.
Tray 4 is the envelope feeder, which is removable at
any time.
Tray 5 is the high capacity input device. ."
::= { prtInputEntry 2 }
prtinputdimunit OBJECT-TYPE
SYNTAX INTEGER {
ePtenThousandthsOfInches(3),
ePmicrometers(4)
}
ACCESS read-only
STATUS optional
DESCRIPTION
"The unit of measurement for use calculating and relaying
dimensional values for this input sub-unit."
::= { prtInputEntry 3 }
prtinputmediadimfeeddirdeclared OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS optional
DESCRIPTION
"This object provides the value of the declared dimension, in
the feed direction, of the media that is (or, if empty, was or
will be) in this input sub-unit. The feed direction is the
direction in which the media is fed on this sub-unit. This
dimension is measured in input sub-unit dimensional units
(prtInputDimUnit). If this input sub-unit can reliably sense
this value, the value is sensed by the printer and may not be
changed by management requests. Otherwise, the value may be
changed. The value (-1) means other and specifically means
that this sub-unit places no restriction on this parameter.
The value (-2) indicates unknown.
Additional information:
For trays 2, 3 and 5 (which can reliably sense this
value) the objects behave exactly the same as prtInputMediaDimFeedDirChosen.
Attempting to set this object for trays 2, 3 and 5 will cause
<noSuchName> to be returned.
The default values assume the trays are configured for
letter size paper.
For tray 1 the value is the dimension for the media size currently declared."
::= { prtInputEntry 4 }
prtinputmediadimxfeeddirdeclared OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS optional
DESCRIPTION
"This object provides the value of the declared dimension, in
the cross feed direction, of the media that is (or, if empty,
was or will be) in this input sub-unit. The cross feed
direction is ninety degrees relative to the feed direction
associated with this sub-unit. This dimension is measured in
input sub-unit dimensional units (prtInputDimUnit). If this
input sub-unit can reliably sense this value, the value is
sensed by the printer and may not be changed by management
requests. Otherwise, the value may be changed. The value (-1)
means other and specifically means that this sub-unit places
no restriction on this parameter. The value (-2) indicates
unknown.
Additional information:
For trays 2, 3 and 5 (which can reliably sense this
value) the objects behave exactly the same as prtInputMediaDimFeedDirChosen.
Attempting to set this object for trays 2, 3 and 5 will cause
<noSuchName> to be returned.
The default values assume the trays are configured for
letter size paper.
For tray 1 the value is the dimension for the media size currently declared."
::= { prtInputEntry 5 }
prtinputmediadimfeeddirchosen OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION
"The printer will act as if media of the chosen dimension (in
the feed direction) is present in this input source. Note
that this value will be used even if the input tray is empty.
Feed dimension measurements
are taken parallel relative to the feed direction
associated with that sub-unit and are in input sub-unit
dimensional units (DimUnit). If the printer supports the
declared dimension, the granted dimension is the same as
the declared dimension. If not, the granted dimension is
set to the closest dimension that the printer supports
when the declared dimension is set. The value (-1) means
other and specifically indicates that this sub-unit
places no restriction on this parameter. The value (-2)
indicates unknown.
Additional information:
The objects for trays 2, 3 and 5 reflect the
configuration of the corresponding drawers. When the drawer is open, a value
of -2 is returned. The default values assume the trays are configured for
letter size paper.
The object for trays 1 and 4 return the value of the media size for which the
tray is currently configured."
::= { prtInputEntry 6 }
prtinputmediadimxfeeddirchosen OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION
"The printer will act as if media of the chosen dimension (in
the cross feed direction) is present in this input source.
Note that this value will be used even if the input tray is
empty. The cross feed direction is ninety degrees relative
to the feed direction associated with this sub-unit. This
dimension is measured in input sub-unit dimensional units
(DimUnit). If the printer supports the declared
dimension, the granted dimension is the same as the
declared dimension. If not, the granted dimension is set
to the closest dimension that the printer supports when
the declared dimension is set. The value (-1) means other
and specifically indicates that this sub-unit places no
restriction on this parameter. The value (-2) indicates
unknown.
Additional information:
The objects for trays 2, 3 and 5 reflect the
configuration of the corresponding drawers. When the drawer is open, a value
of -2 is returned. The default values assume the trays are configured for
letter size paper.
The object for trays 1 and 4 return the value of the media size for which the
tray is currently configured."
::= { prtInputEntry 7 }
prtinputcapacityunit OBJECT-TYPE
SYNTAX INTEGER {
ePtenThousandthsOfInches(3),
ePmicrometers(4),
ePsheets(8),
ePfeet(16),
ePmeters(17)
}
ACCESS read-only
STATUS optional
DESCRIPTION
"The unit of measurement for use in calculating and relaying
capacity values for this input sub-unit.
Additional information:
A sheet is a single piece of 20 pound paper. For tray
4, the envelope feeder, a sheet is one envelope."
::= { prtInputEntry 8 }
prtinputmaxcapacity OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION
"The maximum capacity of the input sub-unit in input
sub-unit capacity units (CapacityUnit). There is no
convention associated with the media itself so this value
reflects claimed capacity. If this input sub-unit can
reliably sense this value, the value is sensed by the
printer and may not be changed by management requests;
otherwise, the value may be written (by a Remote
Contol Panel or a Management Application).
The value (-1) means other and specifically
indicates that the sub-unit places no restrictions
on this parameter. The value (-2) means unknown."
::= { prtInputEntry 9 }
prtinputcurrentlevel OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION
"The current capacity of the input sub-unit in input
sub-unit capacity units (CapacityUnit). If this input
sub-unit can reliably sense this value, the value is
sensed by the printer and may not be changed by
management requests; otherwise, the value may
be written (by a Remote Contol Panel or a
Management Application). The value (-1) means other and
specifically indicates that the sub-unit places no
restrictions on this parameter. The value (-2) means unknown.
The value (-3) means that the printer knows that at least one
unit remains.
Additional information:
For trays 1 and 4, LaserJet 5Si can only detect empty/not
empty trays. It returns -3 for not empty and 0 for
empty.
For trays 2 and 3, LaserJet 5Si can detect approximately the amount of media. The
value returned is based on the amount detected as follows:
0 - empty
1 - 1-110 sheets
50 - 50-260 sheets
200 - 200-490 sheets
430 - 430 sheets or more
For tray 5, LaserJet 5Si can detect approximately the amount of media. The
value returned is based on the amount detected as follows:
0 - empty
1 - 1 sheet to 25% of capacity
500 - 26% to 50% of capacity
1000 - 51% to 75% of capacity
1500 - 76% to 100% of capacity
If the tray drawer is open, a value of -2 (unknown) will be returned."
::= { prtInputEntry 10 }
prtinputstatus OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION
"The current status of this input sub-unit.
The status is an integer that is the sum of 5
distinct values, Availability, Non-Critical, Critical,
On-line, and Transitioning. These values are:
Availability value
Available and Idle 0 000'b
Available and Standby 2 010'b
Available and Active 4 100'b
Available and Busy 6 110'b
Unavailable and OnRequest 1 001'b
Unavailable because Broken 3 011'b
Unknown 5 101'b
Non-Critical
No Non-Critical Alerts 0
Non-Critical Alerts 8
Critical
No Critical Alerts 0
Critical Alerts 16
On-Line
Intended state is On-Line 0
Intended state is Off-Line 32
Transitioning
At intended state 0
Transitioning to intended state 64
Additional information:
See SubUnitStatus in RFC1759 Printer MIB for details on values reported by
this object. LaserJet 5Si will not include values Available and Standby (2),
Available and Active (4) or Unknown (5)."
::= { prtInputEntry 11 }
prtinputmedianame OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..63))
ACCESS read-write
STATUS optional
DESCRIPTION
"A description of the media contained in this input sub-unit;
This description is intended for display to a human operator.
This description is not processed by the printer. It is used
to provide information not expressible in terms of the other
media attributes (e.g. prtInputMediaDimFeedDirChosen,
prtInputMediaDimXFeedDirChosen, prtInputMediaWeight,
prtInputMediaType). An example would be `legal tender bond
paper'.
Additional information:
If set to a string other than one contained by a
MEDIAn-NAME object, a status of
<badValue> is returned.
NOTE: For trays 2, 3, and 5 the following media types
are not available via the front panel:
TRANSPARENCY, LABELS, CARDSTOCK"
::= { prtInputEntry 12 }
prtinputname OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..63))
ACCESS read-only
STATUS optional
DESCRIPTION
"The name assigned to this input sub-unit."
::= { prtInputEntry 13 }
prtinputvendorname OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..63))
ACCESS read-only
STATUS optional
DESCRIPTION
"The vendor name of this input sub-unit."
::= { prtInputEntry 14 }
prtinputmodel OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..63))
ACCESS read-only
STATUS optional
DESCRIPTION
"The model name of this input sub-unit."
::= { prtInputEntry 15 }
prtinputversion OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..63))
ACCESS read-only
STATUS optional
DESCRIPTION
"The version of this input sub-unit."
::= { prtInputEntry 16 }
prtinputserialnumber OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..32))
ACCESS read-only
STATUS optional
DESCRIPTION
"The serial number assigned to this input sub-unit."
::= { prtInputEntry 17 }
prtinputdescription OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..255))
ACCESS read-only
STATUS optional
DESCRIPTION
"A free-form text description of this input
sub-unit in the localization specified by
prtGeneralCurrentLocalization.
Additional information:
"
::= { prtInputEntry 18 }
prtinputsecurity OBJECT-TYPE
SYNTAX INTEGER {
ePother(1),
ePon(3),
ePoff(4),
ePnotPresent(5)
}
ACCESS read-only
STATUS optional
DESCRIPTION
"Indicates if this input sub-unit has some security
associated with it.
Additional information:
No security mechanism provided."
::= { prtInputEntry 19 }
prtoutputdefaultindex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS optional
DESCRIPTION
"The value of prtOutputIndex corresponding to the default
output sub-unit; that is, this object selects the default
output destination."
::= { prtGeneralEntry 7 }
prtoutputtype OBJECT-TYPE
SYNTAX INTEGER {
ePother(1),
ePunknown(2),
ePremovableBin(3),
ePunRemovableBin(4),
ePcontinuousRollDevice(5),
ePmailBox(6),
ePcontinuousFanFold(7)
}
ACCESS read-only
STATUS optional
DESCRIPTION
"The type of technology supported by this output sub-unit."
::= { prtOutputEntry 2 }
prtoutputcapacityunit OBJECT-TYPE
SYNTAX INTEGER {
ePtenThousandthsOfInches(3),
ePmicrometers(4),
ePsheets(8),
ePfeet(16),
ePmeters(17)
}
ACCESS read-only
STATUS optional
DESCRIPTION
"The unit of measurement for use in calculating and relaying
capacity values for this output sub-unit.
Additional information:
A sheet is a single piece of 20 pound paper."
::= { prtOutputEntry 3 }
prtoutputmaxcapacity OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION
"The maximum capacity of this output sub-unit in output
sub-unit capacity units (CapacityUnit). There is no
convention associated with the media itself so this value
essentially reflects claimed capacity. If this output
sub-unit can reliably sense this value, the value is
sensed by the printer and may not be changed by management
requests; otherwise, the value may be written
(by a Remote Contol Panel or a Management Application).
The value (-1) means other and specifically indicates
that the sub-unit places no restrictions on this parameter.
The value (-2) means unknown.
Additional information:
Output sub-unit 2 is not supported if any output paper handling
device is attached.
The capacity of sub-unit 4 depends on the mode of operation. The capcities are
as follows:
Stacker: OutBin1: 125
OutBin2: 1250
OutBin3: 300 (sub-units 5-9 do not exist)
Job Separator: OutBin1: 125
OutBin2: 1250
OutBin3: 300 (sub-units 5-9 do not exist)
Mailbox: OutBin1: 125 (this is the default mode)
OutBin2: 250
OutBin3: 250
OutBin4: 250
OutBin5: 250
OutBin6: 250
OutBin7: 300"
::= { prtOutputEntry 4 }
prtoutputremainingcapacity OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION
"The remaining capacity of the possible output sub-unit
capacity in output sub-unit capacity units (CapacityUnit)
of this output sub-unit. If this output sub-unit can
reliably sense this value, the value is sensed by the
printer and may not be modified by management requests;
otherwise, the value may be written (by
a Remote Contol Panel or a Management
Application). The value (-1) means other and
specifically indicates that the sub-unit places no
restrictions on this parameter. The value (-2) means
unknown. The value (-3) means that the printer knows that
there remains capacity for at least one unit.
Additional information:
The values reported for output sub-unit 1 (face-down, top bin) will be
either (-3) (ie, unknown) if it is not full or (0) if it is full.
Output sub-unit 2 (face-up, left side bin) does
not have any sensing, so it will always report unknown (-2).
The first output sub-unit (3) of the HCO reports
either (-3) (ie, unknown) if it is not full or (0) if it is full.
In mailbox mode,
the HCO sub-units (4-8) will report (250) when empty, (125)
when there's room for <250 sheets and (0) when full. The
STAPLER sub-unit (9) will report (-3) when not full and (0) when full.
In stacker and job separator modes all bins are treated as a single output
bin so sub-unit 4 will report (1250) when all bins are empty. A value of (0)
is reported when the topmost bin is full (stacker mode) or when all bins are
full (separator mode).
When the stacker or separator has started filling, the value reported is based
on the number of bins that are empty, partially filled and full.
A percentage is calculated based on the status of each bin. Each full
bin counts 1, each not empty/not full bin counts 0.5 and each empty bin
counts 0. The result is mapped to an estimate of the remaining capacity as
follows (percent full is included here for completeness, since that is how the
HCO reports it to the printer):
0.0 0 (100%)
0.5 200 ( 90%)
1.0 300 ( 85%)
1.5 400 ( 80%)
2.0 500 ( 75%)
2.5 700 ( 65%)
3.0 800 ( 60%)
3.5 900 ( 55%)
4.0 1000 ( 50%)
4.5 1200 ( 40%)
5.0 1300 ( 35%)
5.5 1400 ( 30%)
6.0 1500 ( 25%)
6.5 1700 ( 15%)
7.0 1800 ( 10%)
7.5 1900 ( 5%)
8.0 2000 ( 0%)
Note: Due to HCO mechanism limitations, the value reported may not always be
accurate (the bin status is detected only when the media
delivery head is moved to or past a physical bin). Also, for stacker mode a
bin is considered full as long as any bin above it is not empty.
Default values assume all sub-units are empty and the HCO is in mailbox mode."
::= { prtOutputEntry 5 }
prtoutputstatus OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION
"The current status of this output sub-unit.
The status is an integer that is the sum of 5
distinct values, Availability, Non-Critical, Critical,
On-line, and Transitioning. These values are:
Availability value
Available and Idle 0 000'b
Available and Standby 2 010'b
Available and Active 4 100'b
Available and Busy 6 110'b
Unavailable and OnRequest 1 001'b
Unavailable because Broken 3 011'b
Unknown 5 101'b
Non-Critical
No Non-Critical Alerts 0
Non-Critical Alerts 8
Critical
No Critical Alerts 0
Critical Alerts 16
On-Line
Intended state is On-Line 0
Intended state is Off-Line 32
Transitioning
At intended state 0
Transitioning to intended state 64
Additional information:
The default values assume all bins are empty.
See SubUnitStatus in RFC1759 Printer MIB for details on values reported by
this object. LaserJet 5Si will not include values Available and Standby (2),
Available and Active (4), Unknown (5) or Transitioning to intended state
(64)."
::= { prtOutputEntry 6 }
prtoutputname OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..19))
ACCESS read-write
STATUS optional
DESCRIPTION
"The name assigned to this output sub-unit.
Additional information:
The characters must be in the range 20H to 7FH except 5C cannot be used. When
this string is displayed on the control panel the Roman-8 symbol set is
used.
The object for bin 2 is not available when the HCO is attached."
::= { prtOutputEntry 7 }
prtoutputvendorname OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..63))
ACCESS read-only
STATUS optional
DESCRIPTION
"The vendor name of this output sub-unit.
Additional information:
"
::= { prtOutputEntry 8 }
prtoutputmodel OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..63))
ACCESS read-only
STATUS optional
DESCRIPTION
"The name assigned to this output sub-unit.
Additional information:
The value returned by Tlatoani depends on the current
mode of the device. The possible values are as follows:
MULTIBIN MAILBOX C3764A [BNPxxxx.x]
MULTIBIN STACKER C3764A [BNPxxxx.x]
MULTIBIN SEPARATOR C3764A[BNPxxxx.x]
STAPLER MODULE C3766A [XX.XX.XX.XX]"
::= { prtOutputEntry 9 }
prtoutputversion OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..63))
ACCESS read-only
STATUS optional
DESCRIPTION
"The version of this output sub-unit.
Additional information:
Returns device-specific information about the configuration
of the output bin. May include information about the type of
processing that can be done to media sent to this bin;
processing includes but is not limited to binding, punching,
folding and sealing. Format of this object is specified by
the output device documentation."
::= { prtOutputEntry 10 }
prtoutputserialnumber OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..63))
ACCESS read-only
STATUS optional
DESCRIPTION
"The serial number assigned to this output sub-unit."
::= { prtOutputEntry 11 }
prtoutputdescription OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..255))
ACCESS read-only
STATUS optional
DESCRIPTION
" A free-form text description of this output sub-unit in the
localization specified by prtGeneralCurrentLocalization."
::= { prtOutputEntry 12 }
prtoutputsecurity OBJECT-TYPE
SYNTAX INTEGER {
ePother(1),
ePon(3),
ePoff(4),
ePnotPresent(5)
}
ACCESS read-only
STATUS optional
DESCRIPTION
"Indicates if this output sub-unit has some security associated
with it and if that security is enabled or not.
Additional information:
No security mechanism provided."
::= { prtOutputEntry 13 }
prtoutputstackingorder OBJECT-TYPE
SYNTAX INTEGER {
ePunknown(2),
ePfirstToLast(3),
ePlastToFirst(4)
}
ACCESS read-only
STATUS optional
DESCRIPTION
"The current state of the stacking order for the
associated output sub-unit. `FirstToLast' means
that as pages are output the front of the next page is
placed against the back of the previous page.
`LasttoFirst' means that as pages are output the back
of the next page is placed against the front of the
previous page. "
::= { prtOutputEntry 19 }
prtoutputpagedeliveryorientation OBJECT-TYPE
SYNTAX INTEGER {
ePfaceUp(3),
ePfaceDown(4)
}
ACCESS read-only
STATUS optional
DESCRIPTION
"The reading surface that will be `up' when pages are
delivered to the associated output sub-unit. Values are
Face-Up and Face-Down. (Note: interpretation of these
values is in general context-dependent based on locale;
presentation of these values to an end-user should be
normalized to the expectations of the user)."
::= { prtOutputEntry 20 }
prtoutputbursting OBJECT-TYPE
SYNTAX INTEGER {
ePother(1),
ePon(3),
ePoff(4),
ePnotPresent(5)
}
ACCESS read-only
STATUS optional
DESCRIPTION
"This object indicates that the outputing sub-unit
supports bursting, and if so, whether the feature is enabled.
Bursting is the process by which continuous media is separated
into individual sheets, typically by bursting along pre-formed
perforations."
::= { prtOutputEntry 21 }
prtoutputdecollating OBJECT-TYPE
SYNTAX INTEGER {
ePother(1),
ePon(3),
ePoff(4),
ePnotPresent(5)
}
ACCESS read-only
STATUS optional
DESCRIPTION
"This object indicates that the output supports
supports decollating, and if so, whether the feature
is enabled. Decollating is the process by which the
individual parts within a multi-part form are separated
and sorted into separate stacks for each part."
::= { prtOutputEntry 22 }
prtoutputpagecollated OBJECT-TYPE
SYNTAX INTEGER {
ePother(1),
ePon(3),
ePoff(4),
ePnotPresent(5)
}
ACCESS read-only
STATUS optional
DESCRIPTION
"This object indicates that the output sub-unit
supports page collation, and if so, whether the feature is
enabled."
::= { prtOutputEntry 23 }
prtoutputoffsetstacking OBJECT-TYPE
SYNTAX INTEGER {
ePother(1),
ePon(3),
ePoff(4),
ePnotPresent(5)
}
ACCESS read-only
STATUS optional
DESCRIPTION
"This object indicates that the output supports
supports offset stacking, and if so, whether the feature is
enabled."
::= { prtOutputEntry 24 }
prtmarkerdefaultindex OBJECT-TYPE
SYNTAX INTEGER(1..65535)
ACCESS read-only
STATUS optional
DESCRIPTION
"The value of prtMarkerIndex corresponding to the
default markersub-unit; that is, this object selects the
default marker."
::= { prtGeneralEntry 8 }
prtmarkermarktech OBJECT-TYPE
SYNTAX INTEGER {
ePother(1),
ePunknown(2),
ePelectrophotographicLED(3),
ePelectrophotographicLaser(4),
ePelectrophotographicOther(5),
ePimpactMovingHeadDotMatrix9pin(6),
ePimpactMovingHeadDotMatrix24pin(7),
ePimpactMovingHeadDotMatrixOther(8),
ePimpactMovingHeadFullyFormed(9),
ePimpactBand(10),
ePimpactOther(11),
ePinkjetAqueous(12),
ePinkjetSolid(13),
ePinkjetOther(14),
ePpen(15),
ePthermalTransfer(16),
ePthermalSensitive(17),
ePthermalDiffusion(18),
ePthermalOther(19),
ePelectroerosion(20),
ePelectrostatic(21),
ePphotographicMicrofiche(22),
ePphotographicImagesetter(23),
ePphotographicOther(24),
ePionDeposition(25),
ePeBeam(26),
ePtypesetter(27)
}
ACCESS read-only
STATUS optional
DESCRIPTION
"The type of marking technology used for this marking sub-unit."
::= { prtMarkerEntry 2 }
prtmarkercounterunit OBJECT-TYPE
SYNTAX INTEGER {
ePtenThousandthsOfInches(3),
ePmicrometers(4),
ePcharacters(5),
ePlines(6),
ePimpressions(7),
ePsheets(8),
ePdotRow(9),
ePhours(11),
ePfeet(16),
ePmeters(17)
}
ACCESS read-only
STATUS optional
DESCRIPTION
"The unit that will be used by the printer when reporting
counter values for this marking sub-unit. The
time units of measure are provided for a device like a
strip recorder that does not or cannot track the physical
dimensions of the media and does not use characters,
lines or sheets."
::= { prtMarkerEntry 3 }
prtmarkerlifecount OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION
"The count of the number of units of measure counted during
the life of printer using units of measure as specified by
CounterUnit.
Additional information:
In LaserJet 5Si the total engine page count is kept in
NVRAM however the NVRAM value is only updated every 10
impressions. NOTE: The value returned by this OID will be
incremented every page but if power is lost between
NVRAM updates, up to 9 impressions of the page count
may be lost. The counter will be reset to
zero after 16,777,215 ( 2^24-1) pages.
The page count is incremented when a sheet of media is pulled from an input
tray. A duplex printed sheet will cause this counter to be incremented by
two."
::= { prtMarkerEntry 4 }
prtmarkerpoweroncount OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION
"The count of the number of units of measure counted since the
equipment was most recently powered on using units of measure as
specified by CounterUnit."
::= { prtMarkerEntry 5 }
prtmarkerprocesscolorants OBJECT-TYPE
SYNTAX INTEGER(0..65535)
ACCESS read-only
STATUS optional
DESCRIPTION
"The number of process colors supported by this marker. A
process color of 1 implies monochrome. The value of this
object and SpotColorants cannot both be 0. Must be 0 or
greater."
::= { prtMarkerEntry 6 }
prtmarkerspotcolorants OBJECT-TYPE
SYNTAX INTEGER(0..65535)
ACCESS read-only
STATUS optional
DESCRIPTION
"The number of spot colors supported by this marker. The
value of this object and ProcessColorants cannot
both be 0. Must be 0 or greater."
::= { prtMarkerEntry 7 }
prtmarkeraddressabilityunit OBJECT-TYPE
SYNTAX INTEGER {
ePtenThousandthsOfInches(3),
ePmicrometers(4)
}
ACCESS read-only
STATUS optional
DESCRIPTION
"The unit of measure of distances."
::= { prtMarkerEntry 8 }
prtmarkeraddressabilityfeeddir OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION
"The number of addressable marking positions in the feed
direction per 10000 units of measure specified by
AddressabilityUnit. A value of (-1) implies 'other' or
'infinite' while a value of (-2) implies 'unknown'."
::= { prtMarkerEntry 9 }
prtmarkeraddressabilityxfeeddir OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION
"The number of addressable marking positions in the cross
feed direction in 10000 units of measure specified by
AddressabilityUnit. A value of (-1) implies 'other' or
'infinite' while a value of (-2) implies 'unknown'."
::= { prtMarkerEntry 10 }
prtmarkernorthmargin OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION
"The margin, in units identified by AddressabilityUnit,
from the leading edge of the medium as the medium flows
throught the marking engine with the side to be imaged
facing the observer. The leading edge is the North edge
and the other edges are defined by the normal compass
layout of directions with the compass facing the
observer. Printing within the area bounded by all four
margins is guaranteed for all interpreters. The value
(-2) means unknown."
::= { prtMarkerEntry 11 }
prtmarkersouthmargin OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION
"The margin from the South edge (see NorthMargin)
of the medium in units identified by
AddressabilityUnit. Printing within the area bounded by
all four margins is guaranteed for all interpreters.
The value (-2) means unknown."
::= { prtMarkerEntry 12 }
prtmarkerwestmargin OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION
"The margin from the West edge (see NorthMargin) of the
medium in units identified by AddressabilityUnit.
Printing within the area bouned by all four margins is
guaranteed for all interpreters. The value (-2) means
unknown."
::= { prtMarkerEntry 13 }
prtmarkereastmargin OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION
"The margin from the East edge (see NorthMargin) of the
medium in units identified by AddressabilityUnit.
Printing within the area bounded by all four margins is
guaranteed for all interpreters. The value (-2) means
unknown."
::= { prtMarkerEntry 14 }
prtmarkerstatus OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION
"The current status of this marker sub-unit.
The status is an integer that is the sum of 5
distinct values, Availability, Non-Critical, Critical,
On-line, and Transitioning. These values are:
Availability value
Available and Idle 0 000'b
Available and Standby 2 010'b
Available and Active 4 100'b
Available and Busy 6 110'b
Unavailable and OnRequest 1 001'b
Unavailable because Broken 3 011'b
Unknown 5 101'b
Non-Critical
No Non-Critical Alerts 0
Non-Critical Alerts 8
Critical
No Critical Alerts 0
Critical Alerts 16
On-Line
Intended state is On-Line 0
Intended state is Off-Line 32
Transitioning
At intended state 0
Transitioning to intended state 64
Additional information:
See SubUnitStatus in RFC1759 Printer MIB for details on values reported by
this object. LaserJet 5Si will not include values
Available and Active (4) or Unknown (5)."
::= { prtMarkerEntry 15 }
prtmarkersuppliesmarkerindex OBJECT-TYPE
SYNTAX INTEGER(0..65535)
ACCESS read-only
STATUS optional
DESCRIPTION
"The value of prtMarkerIndex corresponding to the
marking sub-unit with which this marker supply
sub-unit is associated."
::= { prtMarkerSuppliesEntry 2 }
prtmarkersuppliescolorantindex OBJECT-TYPE
SYNTAX INTEGER(0..65535)
ACCESS read-only
STATUS optional
DESCRIPTION
"The value of prtMarkerColorantIndex
corresponding to the colorant with which this
marker supply sub-unit is associated. This value
shall be 0 if there is no colorant table."
::= { prtMarkerSuppliesEntry 3 }
prtmarkersuppliesclass OBJECT-TYPE
SYNTAX INTEGER {
ePother(1),
ePsupplyThatIsConsumed(3),
ePreceptacleThatIsFilled(4)
}
ACCESS read-only
STATUS optional
DESCRIPTION
"Indicates whether this supply entity represents a supply
container that is consumed or a receptacle that is filled."
::= { prtMarkerSuppliesEntry 4 }
prtmarkersuppliestype OBJECT-TYPE
SYNTAX INTEGER {
ePother(1),
ePunknown(2),
ePtoner(3),
ePwasteToner(4),
ePink(5),
ePinkCartridge(6),
ePinkRibbon(7),
ePwasteInk(8),
ePopc(9),
ePdeveloper(10),
ePfuserOil(11),
ePsolidWax(12),
ePribbonWax(13),
ePwasteWax(14)
}
ACCESS read-only
STATUS optional
DESCRIPTION
"The type of this supply."
::= { prtMarkerSuppliesEntry 5 }
prtmarkersuppliesdescription OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..255))
ACCESS read-only
STATUS optional
DESCRIPTION
"The description of this supply container/receptacle in the
localization specified by prtGeneralCurrentLocalization."
::= { prtMarkerSuppliesEntry 6 }
prtmarkersuppliessupplyunit OBJECT-TYPE
SYNTAX INTEGER {
ePtenThousandthsOfInches(3),
ePmicrometers(4),
ePthousandthsOfOunces(12),
ePtenthsOfGrams(13),
ePhundrethsOfFluidOunces(14),
ePtenthsOfMilliliters(15)
}
ACCESS read-only
STATUS optional
DESCRIPTION
"Unit of this marker supply container/receptacle."
::= { prtMarkerSuppliesEntry 7 }
prtmarkersuppliesmaxcapacity OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION
"The maximum capacity of this supply container/receptacle
expressed in SupplyUnit. If this supply
container/receptacle can reliably sense this value, the
value is sensed by the printer and is read-only;
otherwise, the value may be written (by a Remote Contol
Panel or a Management Application). The value (-1) means
other and specifically indicates that the sub-unit places
no restrictions on this parameter. The value (-2) means
unknown."
::= { prtMarkerSuppliesEntry 8 }
prtmarkersupplieslevel OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION
"The current level if this supply is a container; the
remaining space if this supply is a receptacle. If this
supply container/receptacle can reliably sense this
value, the value is sensed by the printer and is
read-only; otherwise, the value may be written (by a
Remote Contol Panel or a Management Application). The
value (-1) means other and specifically indicates that
the sub-unit places no restrictions on this parameter.
The value (-2) means unknown. A value of (-3) means that the
printer knows that there is some supply/remaining space,
respectively.
Additional information:
LaserJet 5Si detects the toner level as being either
above or below the 'LOW' sensor. Therefore, a value
of -3 is returned when the level is above the 'LOW'
sensor and a value of -2 is returned when the toner
cartridge detects the 'LOW' condition."
::= { prtMarkerSuppliesEntry 9 }
prtmediapathdefaultindex OBJECT-TYPE
SYNTAX INTEGER(1..3)
ACCESS read-write
STATUS optional
DESCRIPTION
"The value of prtMediaPathIndex corresponding to
the default media path; that is, the selection of the
default media path."
::= { prtGeneralEntry 9 }
prtmediapathmaxspeedprintunit OBJECT-TYPE
SYNTAX INTEGER {
ePtenThousandthsOfInchesPerHour(3),
ePmicrometersPerHour(4),
ePcharactersPerHour(5),
ePlinesPerHour(6),
ePimpressionsPerHour(7),
ePsheetsPerHour(8),
ePdotRowPerHour(9),
ePfeetPerHour(16),
ePmetersPerHour(17)
}
ACCESS read-only
STATUS optional
DESCRIPTION
"The unit of measure used in specifying the speed of all media
paths in the printer."
::= { prtMediaPathEntry 2 }
prtmediapathmediasizeunit OBJECT-TYPE
SYNTAX INTEGER {
ePtenThousandthsOfInches(3),
ePmicrometers(4)
}
ACCESS read-only
STATUS optional
DESCRIPTION
"The units of measure of media size for use in calculating and
relaying dimensional values for all media paths in the printer."
::= { prtMediaPathEntry 3 }
prtmediapathmaxspeed OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION
"The maximum printing speed of this media path expressed in
prtMediaPathMaxSpeedUnit's. A value of (-1) implies
'other'.
Additional information:
The page size for this performance is 8.5x11. The
duplex speed is based on 9.5 ppm."
::= { prtMediaPathEntry 4 }
prtmediapathmaxmediafeeddir OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION
"The maximum physical media size in the feed direction of this
media path expressed in units of measure specified by
MediaSizeUnit. A value of (-1) implies 'unlimited'. A value
of (-2) implies 'unknown'
Additional information:
The value returned by this object depends on the value
of prtMediaPathMediaSizeUnit. It is 177000 if prtMediaPathMediaSizeUnit is
ePtenThousandthsOfInches or 449600 if prtMediaPathMediaSizeUnit is
ePmicrometers."
::= { prtMediaPathEntry 5 }
prtmediapathmaxmediaxfeeddir OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION
"The maximum physical media size across the feed direction of
this media path expressed in units of measure specified by
MediaSizeUnit. A value of (-2) implies 'unknown'.
Additional information:
The value returned by this object depends on the value
of prtMediaPathMediaSizeUnit. It is 117000 if prtMediaPathMediaSizeUnit is
ePtenThousandthsOfInches or 297000 if prtMediaPathMediaSizeUnit is
ePmicrometers."
::= { prtMediaPathEntry 6 }
prtmediapathminmediafeeddir OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION
"The minimum physical media size in the feed direction of this
media path expressed in units of measure specified by
MediaSizeUnit. A value of (-2) implies 'unknown'.
Additional information:
The value returned by this object depends on the value
of prtMediaPathMediaSizeUnit. For the simplex paper path it is 75000 if
prtMediaPathMediaSizeUnit is
ePtenThousandthsOfInches or 190500 if prtMediaPathMediaSizeUnit is
ePmicrometers. For the duplex paper path it is 105000 if
prtMediaPathMediaSizeUnit is
ePtenThousandthsOfInches or 266700 if prtMediaPathMediaSizeUnit is
ePmicrometers.
This sizes correspond to a Monarch envelope length for simplex, Executive
paper length for duplex. ( Note: When printing on Custom size media, the
engine will allow a paper size smaller than Executive for the duplex path,
but Executive is the smallest supported size.)"
::= { prtMediaPathEntry 7 }
prtmediapathminmediaxfeeddir OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION
"The minimum physical media size across the feed direction of
this media path expressed in units of measure specified by
MediaSizeUnit. A value of (-2) implies 'unknown'.
Additional information:
The value returned by this object depends on the value
of prtMediaPathMediaSizeUnit. It is 38750 if prtMediaPathMediaSizeUnit is
ePtenThousandthsOfInches or 98425 if prtMediaPathMediaSizeUnit is
ePmicrometers.
This size corresponds to a Monarch envelope for the simplex path, Executive
size for the duplex path. ( Note: When printing on Custom size media, the
engine will allow a paper size smaller than Executive for the duplex path,
but Executive is the smallest supported size.)"
::= { prtMediaPathEntry 8 }
prtmediapathtype OBJECT-TYPE
SYNTAX INTEGER {
ePlongEdgeBindingDuplex(3),
ePshortEdgeBindingDuplex(4),
ePsimplex(5)
}
ACCESS read-only
STATUS optional
DESCRIPTION
"The type of the media path for this media path. "
::= { prtMediaPathEntry 9 }
prtmediapathdescription OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..255))
ACCESS read-only
STATUS optional
DESCRIPTION
"The manufacturer-provided description of this media path in
the localization specified by prtGeneralCurrentLocalization."
::= { prtMediaPathEntry 10 }
prtmediapathstatus OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION
"The current status of this media path.
The status is an integer that is the sum of 5
distinct values, Availability, Non-Critical, Critical,
On-line, and Transitioning. These values are:
Availability value
Available and Idle 0 000'b
Available and Standby 2 010'b
Available and Active 4 100'b
Available and Busy 6 110'b
Unavailable and OnRequest 1 001'b
Unavailable because Broken 3 011'b
Unknown 5 101'b
Non-Critical
No Non-Critical Alerts 0
Non-Critical Alerts 8
Critical
No Critical Alerts 0
Critical Alerts 16
On-Line
Intended state is On-Line 0
Intended state is Off-Line 32
Transitioning
At intended state 0
Transitioning to intended state 64
Additional information:
The default values assume the printer is idle.
See SubUnitStatus in RFC1759 Printer MIB for details on values reported by
this object. LaserJet 5Si will not include values Available and Standby (2),
Available and Active (4), Unknown (5), Non-CriticalAlerts (8) or Transitioning
to intended state (64)."
::= { prtMediaPathEntry 11 }
prtchanneltype OBJECT-TYPE
SYNTAX INTEGER {
ePother(1),
ePchIEEE1284Port(5),
ePchAppleTalkPAP(7),
ePchNetwarePServer(10),
ePchPort9100(11),
ePchDLCLLCPort(15)
}
ACCESS read-only
STATUS optional
DESCRIPTION
"The type of this print data channel. This
object provides the linkage to ChannelType-specific
groups that may (conceptually) extend the prtChannelTable
with additional details about that channel.
Additional information:
MIO-based channels provide their own values."
::= { prtChannelEntry 2 }
prtchannelprotocolversion OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..63))
ACCESS read-only
STATUS optional
DESCRIPTION
"The version of the protocol used on this
channel. The format used for version numbering depends
on prtChannelType.
Additional information:
MIO-based channels provide their own values.
The channel 1 value includes (separated by semi colons) different aspects of
the spec: electrical;logical; and physical connector."
::= { prtChannelEntry 3 }
prtchannelcurrentjobcntllangindex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION
"The value of prtInterpreterIndex corresponding to the
Control Language Interpreter for this channel. This
interpreter defines the syntax used for control
functions, such as querying or changing environment
variables and identifying job boundaries (e.g. PJL,
PostScript, NPAP). Must be 1 or greater.
Additional information:
This object points to the PJL language. It is
read-only because PJL is the printer's only job
control language. It is the same for all channels."
::= { prtChannelEntry 4 }
prtchanneldefaultpagedesclangindex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS optional
DESCRIPTION
"The value of prtInterpreterIndex corresponding to the
Page Description Language Interpreter for this channel.
This interpreter defines the default Page Description
Language interpreter to be used for the print data unless
the Control Language is used to select a specific
interpreter (e.g., PCL, PostScript Language,
auto-sense). Must be 1 or greater.
Additional information:
The default points to the automatic language switcher. If this object
is changed for one channel, all channels will be
changed."
::= { prtChannelEntry 5 }
prtchannelstate OBJECT-TYPE
SYNTAX INTEGER {
ePother(1),
ePprintDataAccepted(3),
ePnoDataAccepted(4)
}
ACCESS read-only
STATUS optional
DESCRIPTION
"The state of this print data channel. The value determines
whether control information and print data is allowed through
this channel or not.
Additional information:
MIO-based channels provide their own values for this
object.
The base-printer's port always reports a value of ePprintDataAccepted. If
the printer is offline, that is detected by reading the Host Resources General
Printer Status objects, not by reading this object."
::= { prtChannelEntry 6 }
prtchannelifindex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION
"The value of ifIndex (in the ifTable; see the interface
section of MIB-2/RFC 1213) which corresponds to this channel.
When more than one row of the ifTable is relevant, this is
the index of the row representing the topmost layer in the
interface hierarchy. A value of zero indicates that no
interface is associated with this channel.
Additional information:
MIO-based channels provide their own values for this
object."
::= { prtChannelEntry 7 }
prtchannelstatus OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION
"The current status of the channel.
The status is an integer that is the sum of 5
distinct values, Availability, Non-Critical, Critical,
On-line, and Transitioning. These values are:
Availability value
Available and Idle 0 000'b
Available and Standby 2 010'b
Available and Active 4 100'b
Available and Busy 6 110'b
Unavailable and OnRequest 1 001'b
Unavailable because Broken 3 011'b
Unknown 5 101'b
Non-Critical
No Non-Critical Alerts 0
Non-Critical Alerts 8
Critical
No Critical Alerts 0
Critical Alerts 16
On-Line
Intended state is On-Line 0
Intended state is Off-Line 32
Transitioning
At intended state 0
Transitioning to intended state 64
Additional information:
See SubUnitStatus in RFC1759 Printer MIB for details
on values reported by this object. MIO-based channels provide their own values
for this object. Status for LaserJet 5Si's parallel port will not include
values Available and Standby (2), Available and Active (4), Non-Critical
Alerts (8) or Transitioning to intended state (64)."
::= { prtChannelEntry 8 }
prtinterpreterlangfamily OBJECT-TYPE
SYNTAX INTEGER {
ePlangPCL(3),
ePlangPJL(5),
ePlangPS(6),
ePlangAutomatic(37)
}
ACCESS read-only
STATUS optional
DESCRIPTION
"The family name of a Page Description Language (PDL) or
control language which this interpreter in the printer can
interpret or emulate. This type 2 list of enumerations
requires review before additional entries are made.
Additional information:
Also provides a place to supply PJL information and
overall ROM information ( by using the language
switcher as a separate language)."
::= { prtInterpreterEntry 2 }
prtinterpreterlanglevel OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..31))
ACCESS read-only
STATUS optional
DESCRIPTION
"The level of the language which this interpreter is
interpreting or emulating. This might contain a value like
'5e' for an interpreter which is emulating level 5e of the PCL
language. It might contain '2' for an interpreter which is
emulating level 2 of the PostScript language. Similarly it
might contain '2' for an interpreter which is emulating level
2 of the HPGL language."
::= { prtInterpreterEntry 3 }
prtinterpreterlangversion OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..31))
ACCESS read-only
STATUS optional
DESCRIPTION
"The date code or version of the language which this interpreter
is interpreting or emulating.
Additional information:
For PostScript, this is more detailed revision
information."
::= { prtInterpreterEntry 4 }
prtinterpreterdescription OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..255))
ACCESS read-only
STATUS optional
DESCRIPTION
"A string to identify this interpreter in the localization
specified by prtGeneralCurrentLocalization as opposed to the
language which is being interpreted. It is anticipated that
this string will allow manufacturers to unambiguously identify
their interpreters.
Additional information:
None of these strings are localized."
::= { prtInterpreterEntry 5 }
prtinterpreterversion OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..31))
ACCESS read-only
STATUS optional
DESCRIPTION
"The date code, version number, or other product specific
information tied to this interpreter. This value is
associated with the interpreter, rather than with the version
of the language which is being interpreted or emulated.
Additional information:
Same as prtInterpreterLangVersion."
::= { prtInterpreterEntry 6 }
prtinterpreterdefaultorientation OBJECT-TYPE
SYNTAX INTEGER {
ePportrait(3),
ePlandscape(4)
}
ACCESS read-write
STATUS optional
DESCRIPTION
"The current orientation default for this interpreter. This
value may be overridden for a particular job (e.g., by a
command in the input data stream).
Additional information:
Setting this object for one interpreter will change it
for all installed interpreters.
Interpreters 1, 2 and 4 ignore the value of this
object."
::= { prtInterpreterEntry 7 }
prtinterpreterfeedaddressability OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION
"The maximum interpreter addressability in the feed
direction in 10000 prtMarkerAddressabilityUnit s (see
prtMarkerAddressabilityFeedDir ) for this interpreter.
The value (-1) means other and specifically indicates
that the sub-unit places no restrictions on this parameter."
::= { prtInterpreterEntry 8 }
prtinterpreterxfeedaddressability OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION
"The maximum interpreter addressability in the cross feed
direction in 10000 prtMarkerAddressabilityUnit s (see
prtMarkerAddressabilityXFeedDir) for this interpreter.
The value (-1) means other and specifically indicates
that the sub-unit places no restrictions on this
parameter."
::= { prtInterpreterEntry 9 }
prtinterpreterdefaultcharsetin OBJECT-TYPE
SYNTAX INTEGER {
ePcsASCII(3),
ePcsISOLatin1(4),
ePcsISOLatin2(5),
ePcsISOLatin5(12),
ePcsISO4UnitedKingdom(20),
ePcsISO11SwedishforNames(21),
ePcsISO15Italian(22),
ePcsISO17Spanish(23),
ePcsISO21German(24),
ePcsISO60DanishNorwegian(25),
ePcsISO69French(26),
ePcsWindows30Latin1(2000),
ePcsWindows31Latin1(2001),
ePcsWindows31Latin2(2002),
ePcsWindows31Latin5(2003),
ePcsHPRoman8(2004),
ePcsAdobeStandardEncoding(2005),
ePcsVenturaUS(2006),
ePcsVenturaInternational(2007),
ePcsPC850Multilingual(2009),
ePcsPCp852(2010),
ePcsPC8CodePage437(2011),
ePcsPC8DNDanishNorwegian(2012),
ePcsHPPC8Turkish(2014),
ePcsHPLegal(2017),
ePcsHPPiFont(2018),
ePcsHPMath8(2019),
ePcsHPPSMath(2020),
ePcsHPDeskTop(2021),
ePcsVenturaMath(2022),
ePcsMicrosoftPublishing(2023),
ePcsWindows31J(2024)
}
ACCESS read-write
STATUS optional
DESCRIPTION
"The default coded character set for input octets
encountered outside a context in which the Page
Description Language established the interpretation
of the octets.
This value shall be (2) if there is no default.
Additional information:
ePcsAdobeStandardEncoding is the same as PSText
( 10J).
The object corresponding to PCL has read-write access;
all others are read-only."
::= { prtInterpreterEntry 10 }
prtinterpreterdefaultcharsetout OBJECT-TYPE
SYNTAX INTEGER {
ePcsNoDefault(2),
ePcsASCII(3),
ePcsHPRoman8(2004),
ePcsAdobeStandardEncoding(2005)
}
ACCESS read-only
STATUS optional
DESCRIPTION
"The default character set for data coming from this interpreter
through the printer's output channel.
This value shall be (2) if there is no default.
Additional information:
"
::= { prtInterpreterEntry 11 }
prtinterpretertwoway OBJECT-TYPE
SYNTAX INTEGER {
ePyes(3),
ePno(4)
}
ACCESS read-only
STATUS optional
DESCRIPTION
"Indicates whether or not this interpreter returns information
back to the host."
::= { prtInterpreterEntry 12 }
prtconsolelocalization OBJECT-TYPE
SYNTAX INTEGER(1..14)
ACCESS read-write
STATUS optional
DESCRIPTION
"The value of the prtLocalizationIndex corresponding to
the language, country, and character set to be used for the
console. This localization applies both to the actual display
on the console as well as the encoding of these console
objects in management operations.
Additional information:
The value of this object is saved in NVRAM.
If a localized string is currently being
displayed on the control panel by the device, changing this object will cause
the displayed string to be changed to its new value. If this object is changed
while the printer is processing a page that
contains localized strings has started, the results are undefined."
::= { prtGeneralEntry 10 }
prtconsolenumberofdisplaylines OBJECT-TYPE
SYNTAX INTEGER(0..65535)
ACCESS read-only
STATUS optional
DESCRIPTION
"The number of lines on the printer's physical
display. This value is 0 if there are no lines on the
physical display or if there is no physical display."
::= { prtGeneralEntry 11 }
prtconsolenumberofdisplaychars OBJECT-TYPE
SYNTAX INTEGER(0..65535)
ACCESS read-only
STATUS optional
DESCRIPTION
"The number of characters per line displayed on the physical
display. This value is 0 if there are no lines on the
physical display or if there is no physical display."
::= { prtGeneralEntry 12 }
prtconsoledisable OBJECT-TYPE
SYNTAX INTEGER {
ePenabled(3),
ePdisabled(4)
}
ACCESS read-write
STATUS optional
DESCRIPTION
"This object enables or disables manual input from the
operators console.
Additional information:
If the object prtConsoleDisable has value 'disabled'
then manual input is not accepted from the operator
console. If the object prtConsoleDisable has the
value 'enabled' then manual input is accepted from the
operator console.
Service Mode is not changed by this object."
::= { prtGeneralEntry 13 }
prtconsoledisplaybuffertext OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..255))
ACCESS read-write
STATUS optional
DESCRIPTION
"The content of a line in the logical display buffer of
the operator's console of the printer. When a write
operation occurs, normally a critical message, to one of
the LineText strings, the agent should make that line
displayable if a physical display is present. Writing
a zero length string clears the line. It is an
implementation-specific matter as to whether the agent allows
a line to be overwritten before it has been cleared.
Printer generated strings shall be in the localization
specified by ConsoleLocalization. Management Application
generated strings should be localized by the Management
Application.
Additional information:
This object does not have to be cleared before a new string is written; the
new string immediately replaces the old one.
When a 79 SERVICE message is displayed, it is not possible to write to this
object ( or any other object for that matter)."
::= { prtConsoleDisplayBufferEntry 2 }
prtconsoleontime OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION
"The on time in milliseconds of blinking of this light; 0
indicates off always. If both prtConsoleOnTime
and prtConsoleOffTime are 0, then the light is
always off.
Additional information:
There are three control panel LED's: Online ( index 1),
Data ( index 2)
and Attention ( index 3). When an LED blinks, it is typically on for one half
second and off for one half second; the value used for this object is 500
whether the LED is on or blinking. "
::= { prtConsoleLightEntry 2 }
prtconsoleofftime OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION
"The off time in milliseconds of blinking of this light; 0
indicates on always. If both prtConsoleOnTime
and prtConsoleOffTime are 0, then the light is
always off.
Additional information:
There are three control panel LED's: Online ( index 1),
Data ( index 2)
and Attention ( index 3). When an LED blinks, it is typically on for one half
second and off for one half second; the value used for this object is 500
when the LED is blinking, otherwise it is zero. "
::= { prtConsoleLightEntry 3 }
prtconsolecolor OBJECT-TYPE
SYNTAX INTEGER {
ePother(1),
ePunknown(2),
ePwhite(3),
ePred(4),
ePgreen(5),
ePblue(6),
ePcyan(7),
ePmagenta(8),
ePyellow(9)
}
ACCESS read-only
STATUS optional
DESCRIPTION
"The color of this light."
::= { prtConsoleLightEntry 4 }
prtconsoledescription OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..255))
ACCESS read-only
STATUS optional
DESCRIPTION
"The vendor description or label of this light in the
localization specified by prtConsoleLocalization."
::= { prtConsoleLightEntry 5 }
prtalertseveritylevel OBJECT-TYPE
SYNTAX INTEGER {
ePother(1),
ePcritical(3),
ePwarning(4)
}
ACCESS read-only
STATUS optional
DESCRIPTION
"The level of severity of this alert table entry. The printer
determines the severity level assigned to each entry into the
table."
::= { prtAlertEntry 2 }
prtalerttraininglevel OBJECT-TYPE
SYNTAX INTEGER {
ePother(1),
ePuntrained(3),
ePtrained(4),
ePfieldService(5),
ePmanagement(6)
}
ACCESS read-only
STATUS optional
DESCRIPTION
"The level of training required to handle this alert. The
training level is an enumeration that is determined and
assigned by the printer manufacturer based on the information
or the training required to handle this alert. The printer
will break alerts into these different training levels. It is
the responsibility of the management application in the system
to determine how a particular alert is handled and how and to
whom that alert is routed. The following are the four
training levels of alerts:
Field Service - Alerts that typically require advanced
training and technical knowledge of the printer
and its sub-units. An example of a technical
person would be a manufacture's Field Service
representative, or other person formally
trained by the manufacturer or similar
representative.
Trained - Alerts that require an intermediate or moderate
level of knowledge of the printer and its
sub-units. A typical examples of alerts that
a trained operator can handle is replacing
toner cartridges.
Untrained - Alerts that can be fixed without prior
training either because the action to correct
the alert is obvious or the printer can help the
untrained person fix the problem. A typical
example of such an alert is reloading paper
trays and emptying output bins on a low end
printer.
Management - Alerts that have to do with overall
operation of and configuration of the printer.
Examples of management events are configuration
change of sub-units.
Additional information:
The value of this object depends on the alert
condition as follows:
ePuntrained: Paper low/out.
ePtrained: Toner low.
ePfieldService: Marker failure.
ePmanagement: Configuration change."
::= { prtAlertEntry 3 }
prtalertgroup OBJECT-TYPE
SYNTAX INTEGER {
ePgeneralPrinter(5),
ePcover(6),
ePinput(8),
ePoutput(9),
ePmarker(10),
ePchannel(14)
}
ACCESS read-only
STATUS optional
DESCRIPTION
"The type of sub-unit within the printer model that this alert
is related. Input, output, and markers are examples of
printer model groups, i.e., examples of types of sub-units.
Whereever possible, these enumerations match the
sub-identifier that identifies the relevant table in the
printmib."
::= { prtAlertEntry 4 }
prtalertgroupindex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION
"An index of the row within the principle table in the
group identified by prtAlertGroup that represents the
sub-unit of the printer that caused this alert. The
combination of the Group and the GroupIndex defines
exactly which printer sub-unit caused the alert.; for
example, Input #3, Output #2, and Marker #1.
Every object in this MIB is indexed with hrDeviceIndex and
optionally, another index variable. If this other index
variable is present in the table that generated the alert, it
will be used as the value for this object. Otherwise, this
value shall be -1."
::= { prtAlertEntry 5 }
prtalertlocation OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION
"The sub-unit location that is defined by the printer
manufacturer to further refine the location of this alert
within the designated sub-unit. The location is used in
conjunction with the Group and GroupIndex values; for
example, there is an alert in Input #2 at location number 7."
::= { prtAlertEntry 6 }
prtalertcode OBJECT-TYPE
SYNTAX INTEGER {
ePother(1),
ePjam(8),
ePdoorOpenAlert(501),
ePinputMediaTrayMissing(801),
ePinputMediaSupplyEmpty(808),
ePoutputMediaTrayFull(903),
ePmarkerFuserUnderTemperature(1001),
ePmarkerFuserOverTemperature(1002),
ePmarkerTonerEmpty(1101),
ePmarkerTonerAlmostEmpty(1104)
}
ACCESS read-only
STATUS optional
DESCRIPTION
"The code that describes the type of alert for this entry in
the table. There are different codes for each
sub-unit type: for example, Media Supply Low and Media
Supply Empty are Aler codes for the Input sub-unit."
::= { prtAlertEntry 7 }
prtalertdescription OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..255))
ACCESS read-only
STATUS optional
DESCRIPTION
"A description of this alert entry in the localization
specified by prtGeneralCurrentLocalization. The description is
provided by the printer to further elaborate on the enumerated
alert or provide information in the case where the code is
classified ask `other' or `unknown'. The printer is required
to return a description string but the string may be a null
string."
::= { prtAlertEntry 8 }
END