-- (C) COPYRIGHT HEWLETT-PACKARD COMPANY 2004.
--
-- LaserJet 2300 Printer Model Specific MIB.
--
-- Generated on Oct. 18, 2004.
--
-- Company names and product names mentioned herein may be
-- trademarks, and/or registered trademarks of their respective
-- companies.
--
-- For internal and external use.
--
-- This MIB describes all the printer model specific
-- objects supported by the LaserJet 2300 printer
-- when networked connected using a JetDirect print
-- server.
--
--
-- This MIB complies with the following RFCs:
--
-- rfc 1157 Simple Network Management Protocol
-- rfc 1155 Structure of Management Information
--
-- Notes:
--
-- 1) Objects containing a string which are defined in this MIB use the
-- first two bytes to hold the symbol set used to encode the string.
-- The Roman-8 symbol set has a hex encoding of 0x0115. Other
-- symbol sets are listed in the PCL 5 Comparison Guide in table
-- C-1 Symbol Set Values.
--
-- 2) Some of the objects included are only supported if an accessory
-- is installed. These accessories include:
-- MIO based accessories
-- SIMM based accessories
-- AT hard disk
-- Paper handling accessories
-- Adobe PostScript accessory
LJ2300-MIB DEFINITIONS ::= BEGIN
hp MODULE-IDENTITY
LAST-UPDATED "0402181325Z"
ORGANIZATION "Hewlett-Packard Company"
CONTACT-INFO
"Customer Care Center
Tel: +1 800-474-6836
WEB: http://www.hp.com"
DESCRIPTION "Objects used in the HP LaserJet 2300 printer."
::= { iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) 11}
netPMLmgmt OBJECT IDENTIFIER ::= { hp nm(2) system(3) netPeripheral(9) netPML(4) 2}
DisplayString ::= OCTET STRING
device OBJECT IDENTIFIER ::= { netPMLmgmt 1 }
device-system OBJECT IDENTIFIER ::= { device 1 }
status-system OBJECT IDENTIFIER ::= { device-system 2 }
test OBJECT IDENTIFIER ::= { device-system 5 }
background-message OBJECT IDENTIFIER ::= { status-system 37 }
background-message1 OBJECT IDENTIFIER ::= { background-message 1 }
background-message2 OBJECT IDENTIFIER ::= { background-message 2 }
control-panel-display OBJECT IDENTIFIER ::= { status-system 65 }
settings-system OBJECT IDENTIFIER ::= { device-system 1 }
interface OBJECT IDENTIFIER ::= { device-system 4 }
simm OBJECT IDENTIFIER ::= { interface 1 }
simm1 OBJECT IDENTIFIER ::= { simm 1 }
simm1-bank OBJECT IDENTIFIER ::= { simm1 6 }
simm1-bank1 OBJECT IDENTIFIER ::= { simm1-bank 1 }
simm1-bank2 OBJECT IDENTIFIER ::= { simm1-bank 2 }
simm2 OBJECT IDENTIFIER ::= { simm 2 }
simm2-bank OBJECT IDENTIFIER ::= { simm2 6 }
simm2-bank1 OBJECT IDENTIFIER ::= { simm2-bank 1 }
simm2-bank2 OBJECT IDENTIFIER ::= { simm2-bank 2 }
simm3 OBJECT IDENTIFIER ::= { simm 3 }
simm3-bank OBJECT IDENTIFIER ::= { simm3 6 }
simm3-bank1 OBJECT IDENTIFIER ::= { simm3-bank 1 }
simm3-bank2 OBJECT IDENTIFIER ::= { simm3-bank 2 }
job OBJECT IDENTIFIER ::= { device-system 6 }
settings-job OBJECT IDENTIFIER ::= { job 1 }
operating-system OBJECT IDENTIFIER ::= { device-system 19 }
processing-subsystem OBJECT IDENTIFIER ::= { device 3 }
pdl OBJECT IDENTIFIER ::= { processing-subsystem 3 }
settings-pdl OBJECT IDENTIFIER ::= { pdl 1 }
status-pdl OBJECT IDENTIFIER ::= { pdl 2 }
errorlog OBJECT IDENTIFIER ::= { device-system 11 }
error1 OBJECT IDENTIFIER ::= { errorlog 1 }
error2 OBJECT IDENTIFIER ::= { errorlog 2 }
error3 OBJECT IDENTIFIER ::= { errorlog 3 }
error4 OBJECT IDENTIFIER ::= { errorlog 4 }
error5 OBJECT IDENTIFIER ::= { errorlog 5 }
error6 OBJECT IDENTIFIER ::= { errorlog 6 }
error7 OBJECT IDENTIFIER ::= { errorlog 7 }
error8 OBJECT IDENTIFIER ::= { errorlog 8 }
error9 OBJECT IDENTIFIER ::= { errorlog 9 }
error10 OBJECT IDENTIFIER ::= { errorlog 10 }
error11 OBJECT IDENTIFIER ::= { errorlog 11 }
error12 OBJECT IDENTIFIER ::= { errorlog 12 }
error13 OBJECT IDENTIFIER ::= { errorlog 13 }
error14 OBJECT IDENTIFIER ::= { errorlog 14 }
error15 OBJECT IDENTIFIER ::= { errorlog 15 }
error16 OBJECT IDENTIFIER ::= { errorlog 16 }
error17 OBJECT IDENTIFIER ::= { errorlog 17 }
error18 OBJECT IDENTIFIER ::= { errorlog 18 }
error19 OBJECT IDENTIFIER ::= { errorlog 19 }
error20 OBJECT IDENTIFIER ::= { errorlog 20 }
error21 OBJECT IDENTIFIER ::= { errorlog 21 }
error22 OBJECT IDENTIFIER ::= { errorlog 22 }
error23 OBJECT IDENTIFIER ::= { errorlog 23 }
error24 OBJECT IDENTIFIER ::= { errorlog 24 }
error25 OBJECT IDENTIFIER ::= { errorlog 25 }
error26 OBJECT IDENTIFIER ::= { errorlog 26 }
error27 OBJECT IDENTIFIER ::= { errorlog 27 }
error28 OBJECT IDENTIFIER ::= { errorlog 28 }
error29 OBJECT IDENTIFIER ::= { errorlog 29 }
error30 OBJECT IDENTIFIER ::= { errorlog 30 }
error31 OBJECT IDENTIFIER ::= { errorlog 31 }
error32 OBJECT IDENTIFIER ::= { errorlog 32 }
error33 OBJECT IDENTIFIER ::= { errorlog 33 }
error34 OBJECT IDENTIFIER ::= { errorlog 34 }
error35 OBJECT IDENTIFIER ::= { errorlog 35 }
error36 OBJECT IDENTIFIER ::= { errorlog 36 }
error37 OBJECT IDENTIFIER ::= { errorlog 37 }
error38 OBJECT IDENTIFIER ::= { errorlog 38 }
error39 OBJECT IDENTIFIER ::= { errorlog 39 }
error40 OBJECT IDENTIFIER ::= { errorlog 40 }
error41 OBJECT IDENTIFIER ::= { errorlog 41 }
error42 OBJECT IDENTIFIER ::= { errorlog 42 }
error43 OBJECT IDENTIFIER ::= { errorlog 43 }
error44 OBJECT IDENTIFIER ::= { errorlog 44 }
error45 OBJECT IDENTIFIER ::= { errorlog 45 }
error46 OBJECT IDENTIFIER ::= { errorlog 46 }
error47 OBJECT IDENTIFIER ::= { errorlog 47 }
error48 OBJECT IDENTIFIER ::= { errorlog 48 }
error49 OBJECT IDENTIFIER ::= { errorlog 49 }
error50 OBJECT IDENTIFIER ::= { errorlog 50 }
channel OBJECT IDENTIFIER ::= { device 6 }
display OBJECT IDENTIFIER ::= { status-system 20 }
display-status OBJECT IDENTIFIER ::= { display 1 }
id OBJECT IDENTIFIER ::= { device-system 3 }
pdl-pcl OBJECT IDENTIFIER ::= { pdl 3 }
pdl-postscript OBJECT IDENTIFIER ::= { pdl 4 }
socket-ping OBJECT IDENTIFIER ::= { interface 7 }
active-print-jobs OBJECT IDENTIFIER ::= { job 2 }
job-being-parsed OBJECT IDENTIFIER ::= { active-print-jobs 1 }
job-info OBJECT IDENTIFIER ::= { job 5 }
job-info-attribute OBJECT IDENTIFIER ::= { job-info 23 }
job-info-accounting OBJECT IDENTIFIER ::= { job-info 28 }
held-job OBJECT IDENTIFIER ::= { job 7 }
held-job-info OBJECT IDENTIFIER ::= { held-job 1 }
held-job-control OBJECT IDENTIFIER ::= { held-job 2 }
source-subsystem OBJECT IDENTIFIER ::= { device 2 }
spooler OBJECT IDENTIFIER ::= { source-subsystem 4 }
settings-spooler OBJECT IDENTIFIER ::= { spooler 1 }
pjl OBJECT IDENTIFIER ::= { processing-subsystem 5 }
mio OBJECT IDENTIFIER ::= { interface 3 }
mio1 OBJECT IDENTIFIER ::= { mio 1 }
mio2 OBJECT IDENTIFIER ::= { mio 2 }
mio3 OBJECT IDENTIFIER ::= { mio 3 }
io OBJECT IDENTIFIER ::= { source-subsystem 1 }
settings-io OBJECT IDENTIFIER ::= { io 1 }
ports OBJECT IDENTIFIER ::= { io 3 }
port1 OBJECT IDENTIFIER ::= { ports 1 }
tables OBJECT IDENTIFIER ::= { device 7 }
remote-procedure-call OBJECT IDENTIFIER ::= { device-system 13 }
settings-rpc OBJECT IDENTIFIER ::= { remote-procedure-call 1 }
status-rpc OBJECT IDENTIFIER ::= { remote-procedure-call 2 }
file-system OBJECT IDENTIFIER ::= { device-system 10 }
settings-file-system OBJECT IDENTIFIER ::= { file-system 1 }
file-systems OBJECT IDENTIFIER ::= { file-system 3 }
file-system2 OBJECT IDENTIFIER ::= { file-systems 2 }
file-system3 OBJECT IDENTIFIER ::= { file-systems 3 }
file-system4 OBJECT IDENTIFIER ::= { file-systems 4 }
resource-manager OBJECT IDENTIFIER ::= { device-system 12 }
mass-storage-resources OBJECT IDENTIFIER ::= { resource-manager 3 }
mass-storage-block-driver OBJECT IDENTIFIER ::= { device-system 15 }
settings-mass-storage-bd OBJECT IDENTIFIER ::= { mass-storage-block-driver 1 }
status-mass-storage-bd OBJECT IDENTIFIER ::= { mass-storage-block-driver 2 }
device-configure OBJECT IDENTIFIER ::= { settings-system 32 }
destination-subsystem OBJECT IDENTIFIER ::= { device 4 }
print-engine OBJECT IDENTIFIER ::= { destination-subsystem 1 }
settings-prt-eng OBJECT IDENTIFIER ::= { print-engine 1 }
marking-agent-density OBJECT IDENTIFIER ::= { settings-prt-eng 9 }
status-prt-eng OBJECT IDENTIFIER ::= { print-engine 2 }
intray OBJECT IDENTIFIER ::= { print-engine 3 }
settings-intray OBJECT IDENTIFIER ::= { intray 1 }
intrays OBJECT IDENTIFIER ::= { intray 3 }
intray1 OBJECT IDENTIFIER ::= { intrays 1 }
intray2 OBJECT IDENTIFIER ::= { intrays 2 }
intray3 OBJECT IDENTIFIER ::= { intrays 3 }
outbin OBJECT IDENTIFIER ::= { print-engine 4 }
settings-outbin OBJECT IDENTIFIER ::= { outbin 1 }
outbins OBJECT IDENTIFIER ::= { outbin 3 }
outbin1 OBJECT IDENTIFIER ::= { outbins 1 }
ph OBJECT IDENTIFIER ::= { print-engine 7 }
ph-devices OBJECT IDENTIFIER ::= { ph 3 }
ph2 OBJECT IDENTIFIER ::= { ph-devices 2 }
ph3 OBJECT IDENTIFIER ::= { ph-devices 3 }
ph4 OBJECT IDENTIFIER ::= { ph-devices 4 }
ph5 OBJECT IDENTIFIER ::= { ph-devices 5 }
ph6 OBJECT IDENTIFIER ::= { ph-devices 6 }
print-media OBJECT IDENTIFIER ::= { print-engine 8 }
settings-print-media OBJECT IDENTIFIER ::= { print-media 1 }
media-info OBJECT IDENTIFIER ::= { print-media 3 }
media1 OBJECT IDENTIFIER ::= { media-info 1 }
media2 OBJECT IDENTIFIER ::= { media-info 2 }
media3 OBJECT IDENTIFIER ::= { media-info 3 }
media4 OBJECT IDENTIFIER ::= { media-info 4 }
media5 OBJECT IDENTIFIER ::= { media-info 5 }
media6 OBJECT IDENTIFIER ::= { media-info 6 }
media7 OBJECT IDENTIFIER ::= { media-info 7 }
media8 OBJECT IDENTIFIER ::= { media-info 8 }
media9 OBJECT IDENTIFIER ::= { media-info 9 }
media10 OBJECT IDENTIFIER ::= { media-info 10 }
media11 OBJECT IDENTIFIER ::= { media-info 11 }
media15 OBJECT IDENTIFIER ::= { media-info 15 }
media16 OBJECT IDENTIFIER ::= { media-info 16 }
media17 OBJECT IDENTIFIER ::= { media-info 17 }
media18 OBJECT IDENTIFIER ::= { media-info 18 }
media19 OBJECT IDENTIFIER ::= { media-info 19 }
media21 OBJECT IDENTIFIER ::= { media-info 21 }
media32 OBJECT IDENTIFIER ::= { media-info 32 }
media-modes OBJECT IDENTIFIER ::= { print-media 4 }
media-size OBJECT IDENTIFIER ::= { print-media 5 }
accounting OBJECT IDENTIFIER ::= { device-system 16 }
printer-accounting OBJECT IDENTIFIER ::= { accounting 1 }
printed-media-usage OBJECT IDENTIFIER ::= { printer-accounting 1 }
marking-agent OBJECT IDENTIFIER ::= { print-engine 5 }
settings-marking-agent OBJECT IDENTIFIER ::= { marking-agent 1 }
consumables OBJECT IDENTIFIER ::= { print-engine 10 }
consumables-1 OBJECT IDENTIFIER ::= { consumables 1 }
consumable-status OBJECT IDENTIFIER ::= { consumables-1 1 }
consumables-status OBJECT IDENTIFIER ::= { consumables 5 }
consumables-life OBJECT IDENTIFIER ::= { consumables-status 1 }
print-meter OBJECT IDENTIFIER ::= { print-engine 11 }
printer-average OBJECT IDENTIFIER ::= { print-meter 1 }
webserver-proc-sub OBJECT IDENTIFIER ::= { processing-subsystem 9 }
settings-webserver OBJECT IDENTIFIER ::= { webserver-proc-sub 1 }
firmware-download OBJECT IDENTIFIER ::= { device-system 18 }
upgradable-devices OBJECT IDENTIFIER ::= { device-system 20 }
perm-store-init-occurred OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-only
STATUS optional
DESCRIPTION
"This object will set the cAllPermDevices bit when a full perm
storage initialization occurs (as would be the case for a brand
new system or as a result of a powerup key sequence or
PE-TEST-POWERUP-KEY-SEQUENCE object request). If only one
device was initialized (as would be the case if a disk were
added to an existing system or a formatter were swapped out),
then only the appropriate collection bits will be returned. If
there are no collection bits set then this indicates that no
initialization took place."
::= { status-system 10 }
self-test OBJECT-TYPE
SYNTAX INTEGER {
eNotInASelfTest(1),
eNonDestructiveSelfTest(4)
}
ACCESS read-write
STATUS optional
DESCRIPTION
"Writing this object allows a device self test to be started.
Reading this object provides an indication what self-test is
currently executing, if any. Actual self-test operation is
device specific. A self test may not be allowed at any
arbitrary time. If the device supports the requested self test,
but can not start the execution of the self test when
requested, the device will respond with
<genErr>. If a non-destructive self
test is being started, the device will generate a response
before the self test is completed. RECOMMENDATION: If the
device is ready (i.e. the NOT-READY-PRINTER object does not
contain any items, except maybe being off-line) and is idle
(i.e. the NOT-IDLE object does not contain any items), this
request should always succeed. This provides a mechanism for
driver writers to always determine if the action will succeed
or not.
Additional information:
The eNonDestructiveSelfTest performs limited
testing on the printer and its attached paper handling
devices. After the self-test is complete a
configuration page is printed. The recommended
way to cause a configuration page to be printed is to
use the PRINT-INTERNAL-PAGE object.
Setting this object to eNonDestructiveSelfTest results in a status of <noError>
and a value of eNonDestructiveSelfTest being returned.
If the printer is not idle (whether printing an external job or printing
an internal page), this action will be delayed until the next job boundary.
See the PRINT-INTERNAL-PAGE object for more details."
::= { test 1 }
print-internal-page OBJECT-TYPE
SYNTAX INTEGER {
eNotPrintingAnInternalPage(1),
ePrintingAnUnknownInternalPage(2),
eDeviceDemoPage1ConfigurationPage(3),
eDeviceDemoPage5ErrorLog(7),
eDeviceDemoPage6FileSystemDirectoryListing(8),
eDeviceDemoPage7MenuMap(9),
ePrintUsagePage(100),
eSuppliesPage(101),
ePCLFontList1(350),
ePSFontList(450)
}
ACCESS read-write
STATUS optional
DESCRIPTION
"Writing this object to a value other than
eNotPrintingAnInternalPage causes the device to attempt to
print an internally generated page. Reading this object
provides an indication what internally generated page is
currently being printed, if any. The actual page is device
specific. Some devices may support continuously printing an
internally generated page. Setting this object to
eNotPrintingAnInternalPage terminates continuously printing
internally generated pages. An internally generated page may
not be allowed to be printed at any arbitrary time; under what
conditions it will succeed or fail is device specific. If the
device supports the requested page, but can not start printing
the page when requested, the device will respond with
<genErr>. RECOMMENDATION: If the
device is ready (i.e. the NOT-READY-PRINTER object does not
contain any items, except maybe being off-line) and is idle
(i.e. the NOT-IDLE object does not contain any items), this
request should always succeed. This provides a mechanism for
driver writers to always determine if the action will succeed
or not.
Additional information:
Previous products used
ePCLDemoPage1ConfigurationPage(300) for the
Configuration or Self Test page. This product uses
eDeviceDemoPage1ConfigurationPage(3).
LaserJet 8150 does not support continuously printing a demo page.
When this object is set to a valid value, the status returned is <noError>
and the value returned is ePrintingAnUnknownInternalPage. If the printer
is idle, the page will be printed immediately. If the printer is
currently printing another job, the internal page requested will not print
until that job is finished.
Setting this object to a valid value causes the
desired page to be formatted and put in the printer's
print queue. While the page is being formatted a get on this object will
return the value ePrintingAnUnknownInternalPage. Once the page (or pages)
is finished being formatted, this object returns a value of
eNotPrintingAnInternalPage, even though the page may not have finished
being printed.
Setting this object multiple times will queue up the requests, but only
a limited number will be queued. Once the queue is full, additional
requests will be ignored."
::= { test 2 }
localization-languages-supported OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS optional
DESCRIPTION
"The list of languages supported by the device. The languages
are primarily, but not limited to, two character codes from ISO
639, each separated by a comma character.
Additional information:
This string will always be in the Roman-8 character set.
See prtLocalizationLanguage for details about each language value."
::= { status-system 52 }
localization-countries-supported OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS optional
DESCRIPTION
"The list of countries supported by the device. The countries
are primarily, but not limited to, two character codes from ISO
3166, each separated by a comma character.
Additional information:
This string will always be in the Roman-8 character set.
See prtLocalizationCountry for details about each country value."
::= { status-system 53 }
background-status-msg-line1-part1 OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..16))
ACCESS read-write
STATUS optional
DESCRIPTION
"The string displayed on the device's front panel in place of
the printer's built-in background status string. An example
built-in background status string is '00 READY'.
Additional information:
The display size for the LaserJet 8150 printers is 2 X 16.
The value of this object and the current value of
BACKGROUND-STATUS-MSG-LINE2-PART1 are displayed
together on the 2-line display, but they must
be set independently. If line 2 has been set, and the
next message to be displayed only requires line 1,
BACKGROUND-STATUS-MSG-LINE2-PART1 must be set to the
null string to clear it.
This object allows a message to be displayed when
it is the highest priority message. Setting this
object does not guarantee the message will be
displayed; and reading it returns the value last
written, not the currently displayed message (use
prtConsoleDisplayBufferText to read the
display).
The priority assigned for displaying this message
is one lower than the READY message. In other words,
the only message that can be replaced by these
objects is the READY message.
To clear the message, write a null string to both
this object and BACKGROUND-STATUS-MSG-LINE2-PART1.
Additional information:
The display size for the LaserJet 8150 printers is 2 X 16.
The value of this object and the current value of
BACKGROUND-STATUS-MSG-LINE2-PART1 are displayed
together on the 2-line display, but they must
be set independently. If line 2 has been set, and the
next message to be displayed only requires line 1,
BACKGROUND-STATUS-MSG-LINE2-PART1 must be set to the
null string to clear it.
This object allows a message to be displayed when
it is the highest priority message. Setting this
object does not guarantee the message will be
displayed; and reading it returns the value last
written, not the currently displayed message (use
prtConsoleDisplayBufferText to read the
display).
The priority assigned for displaying this message
is one lower than the READY message. In other words,
the only message that can be replaced by these
objects is the READY message.
To clear the message, write a null string to both
this object and BACKGROUND-STATUS-MSG-LINE2-PART1."
::= { background-message1 1 }
background-status-msg-line2-part1 OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..16))
ACCESS read-write
STATUS optional
DESCRIPTION
"The string displayed on the device's front panel in place of
the printer's built-in background status string. An example
built-in background status string is '00 READY'.
Additional information:
See BACKGROUND-STATUS-MSG-LINE1-PART1
Additional information:
See BACKGROUND-STATUS-MSG-LINE1-PART1"
::= { background-message2 1 }
control-panel-button-press OBJECT-TYPE
SYNTAX INTEGER {
eGoButton(1),
eMenuPlusButton(2),
eMenuMinusButton(3),
eItemPlusButton(4),
eItemMinusButton(5),
eValuePlusButton(6),
eValueMinusButton(7),
eSelectButton(8),
eCancelJobButton(9),
ePauseResumeButton(10),
eUpArrowButton(11),
eDownArrowButton(12),
eBackButton(13),
eQuestionMarkButton(14),
eClearButton(15),
eNumericButton0(16),
eNumericButton1(17),
eNumericButton2(18),
eNumericButton3(19),
eNumericButton4(20),
eNumericButton5(21),
eNumericButton6(22),
eNumericButton7(23),
eNumericButton8(24),
eNumericButton9(25),
eRotateButton(26),
eInfoButton(27),
eMenuButton(28),
eStopButton(29)
}
ACCESS read-write
STATUS optional
DESCRIPTION
"Writing this object simulates pressing a button on the control
panel. Reading it will return the last key pressed either on
the control panel or via PML. The device POS will specify which
keys are supported."
::= { status-system 60 }
control-panel-display-contents-change-counter OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION
"A counter which increments whenever the contents of the front
panel display changes. This object is implemented as a 32-bit
signed integer which rolls over to zero when it reaches a
maximum value."
::= { status-system 63 }
control-panel-display-contents-crc OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION
"Reading this object returns a 32-bit Cyclical Redundancy Check
(CRC) which represents the current contents of the display.
Additional information:
This object has been implimented as an 8-bit CRC for
this product."
::= { status-system 64 }
control-panel-display-graphical-contents OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-only
STATUS optional
DESCRIPTION
"Reading this object returns a graphical file format image
representing the current pixel content of the display. The
device POS will specify the expected screen resolution, color
depth of the display and graphics file format for a given
product (eg. 160x64x1 GIF format OR 640x240x4 JPEG format). If
the image is large enough that it needs to be returned in
multiple objects then each array object will contain a portion
of the image. The image will then need to be reconstructed by a
host application. An application that needs to determine if
their is an additional object to be retreived will need to
perform a GETNEXT operation until there are no more objects in
the sub-tree.
Additional information:
This object returns a GIF image that represents the
current contents of the 160x32x1 control panel display. Most
display images require more than one instance of this object
in order to retreive the complete GIF image."
::= { control-panel-display 1 }
energy-star OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS optional
DESCRIPTION
"Returns or changes the Energy Star sleep value. If the value
is greater than zero, then the device will go into energy
saving sleep mode after the print engine has been idle for the
number of seconds specified by this object. A value of zero
means Energy Star is disabled and the device will not go to
sleep based on print engine idle time. The value must be
non-negative.
Additional information:
Returns or changes the Energy Star sleep value.
The device will go into energy saving sleep
mode after the print engine has been idle for
the number of seconds specified by this
object.
LaserJet 2300 supports values of 0, 60, 900, 1800,
3600, 7200, 14400 seconds. A value of 0 means
never enter sleep mode based on the print engine
idle time. Setting to an unsupported value causes
the printer to substitute a value (listed
below) and to return <noError>
status. Setting this value when the printer is in
sleep mode will not cause it to wakeup unless it is
set to 0.
The values are as follow:
<=0 snap to 0
>=1 and <= 479 snap to 60 (1 minute)
>=480 and <= 1349 snap to 900 (15 minutes)
>=1350 and <= 2699 snap to 1800 (30 minutes)
>=2700 and <= 4499 snap to 3600 (1 hour)
>=4500 and <= 6299 snap to 5400 (90 minutes)
>=5400 and <= 10799 snap to 7200 (2 hours)
>=10800 snap to 14400 (4 hours)."
::= { settings-system 1 }
sleep-mode OBJECT-TYPE
SYNTAX INTEGER {
eFalse(1),
eTrue(2)
}
ACCESS read-write
STATUS optional
DESCRIPTION
"Returns eTrue if the device is in energy saving sleep mode,
otherwise returns eFalse. Setting SLEEP-MODE to eFalse causes
the device to wake up, if it is in sleep mode. Setting
SLEEP-MODE to eTrue causes the device to go into sleep mode.
Additional information:
This object returns eTrue if the device is in
energy saving sleep mode, otherwise it returns eFalse.
Setting this object to eTrue while the printer
is awake will not change the printer's current state
and will return <genErr>
status. NOTE: This object should behave this way
when the printer does not have an instant-on fuser.
Setting this object to eTrue while printer is already
in Sleep Mode will not change the printer's
current state and will return <noError> status.
Setting this object to eFalse while printer is already
awake will not change the printer's current state and
will return <noError> status.
Setting this object to eFalse while the printer is
asleep causes the device to wake up. "
::= { settings-system 2 }
on-off-line OBJECT-TYPE
SYNTAX INTEGER {
eOnline(1),
eOffline(2),
eOfflineAtEndOfJob(3)
}
ACCESS read-write
STATUS optional
DESCRIPTION
"To bring the PDL processing sub-system on or off line. If the
device is a printer, then the printer does not process print
job data when the printer is off line. PML communication
persists.
Additional information:
When the printer is in the Offline state,
printing will stop as soon as possible (no more sheets
of media are pulled from input trays). The I/O
is taken offline also.
Setting to eOnline has the following affect:
Printer will immediately go to or remain in the Online
state; <noError> status is returned.
If the printer's current state
is Offline with a pending error condition that
prevents the printer from going to the Online
state, the printer will remain in the Offline state;
<genErr> status is returned
Setting to eOffline has the following affect:
Printer will immediately go to or remain in the
Offline state; <noError> status is returned.
If pages are being printed, those pages will complete
with the printer in the Offline state.
Setting to eOfflineAtEndOfJob has the following
affect:
If not in a job or already in the Offline state, the
printer will immediately go to or remain in the
Offline state; <noError> status is returned.
If in a job and the current state is Online, the
printer will remain in the Online state, with the
value of this object as eOfflineAtEndOfJob, until the
end of the job; <noError> status is returned. At the end of
the job, the printer goes to the Offline state and the
value of this object becomes eOffline.
Setting this object to eOffline or eOnline before the
end of the job causes the action for that value to be
taken immediately."
::= { status-system 5 }
continue OBJECT-TYPE
SYNTAX INTEGER {
eInitiateAction(1)
}
ACCESS write-only
STATUS optional
DESCRIPTION
"A device can support a class of errors called continuable
errors. When a continuable error is encountered, the device
requires a continue event to occur before the device will
continue operation. One continue event is setting the CONTINUE
object to eInitiateAction. Devices can support other continue
events, like auto-continue. A continue event causes the
continuable error to be acknowledged, thus allowing the device
to continue. Each device needs to list the continuable errors.
If the device doesn't currently have an unacknowledged
continuable error, the response will contain
<genErr>.
Additional information:
See the CLEARABLE-WARNING and AUTO-CONTINUE objects for the
errors that this object will clear."
::= { status-system 6 }
auto-continue OBJECT-TYPE
SYNTAX INTEGER {
eOff(1),
eOn(2)
}
ACCESS read-write
STATUS optional
DESCRIPTION
"Indicates if the device will automatically continue after
encountering a continuable error. If AUTO-CONTINUE is set to
eOn, the device will automatically generate continue event to
acknowledge continuable errors. If AUTO-CONTINUE is set to
eOff, then some other continue event will have to acknowledge
the continuable error.
Additional information:
If this is set to eOn the device displays an
error message and goes offline for ten seconds. After ten seconds the
printer automatically returns to the online state.
If this is set to eOff then the device displays an error message and
goes offline. It remains offline until the operator presses the GO key or
until the CONTINUE object is set.
If the printer is not idle, the new value may not take effect
until a job boundary is reached. If a get is done on this object before
the job boundary is reached, the value last set will be returned."
::= { status-system 7 }
simm1-type OBJECT-TYPE
SYNTAX INTEGER {
eEmpty(1),
eUnknown(2),
eUnSupported(3),
eReadOnlyMemory(4),
eVolatileRandomAccessMemory(5),
eFlashMemory(7),
eRamRom(9)
}
ACCESS read-only
STATUS optional
DESCRIPTION
"Returns an indication of the type of option installed in SIMM
slot 1.
eEmpty means the device did not detect any option installed
in the interface slot.
eUnknown means the device doesn't recognize the installed
option.
eUnSupported means the device recognizes the installed
option, but does not support the option.
eReadOnlyMemory means the installed option contains ROM
Ics.
eVolatileRandomAccessMemory means the installed option
contains RAM ICs that loose data when the power is
turned off.
eNonVolatileRandomAccessMemory means that the installed
option contains RAM ICs that do not loose data when the
power is turned off.
eFlashMemory means that the installed option contains a
type of non-volatile RAM that needs to be erased before
it can be written.
eDiskDrive means the installed option contains a disk
drive.
eRamRom means the installed option contains both volatile
random access memory and read only memory.
eInputPHD means the installed option is an input paper
handling device.
eOutputPHD means the installed option is an output paper
handling device. eIOCard means the installed option is
an I/O card.
Additional information:
This object is used for describing DIMMs instead
of SIMMs on LaserJet 8150. eRamRom is used to denote LaserJet 8150's combo simm."
::= { simm1 4 }
simm1-capacity OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION
"Returns an indication of the capacity of the SIMM installed in
SIMM slot 1. The capacity is dependent on the type of option,
as indicated by the SIMM1-TYPE object. This object has no
meaning if the installed option type is eUnknown or
eReadOnlyMemory. This object contains the size, in bytes, if
the installed option type is eVolatileRandomAccessMemory,
eNonVolatileRandomAccessMemory, eFlashMemory, or eDiskDrive. If
the type of the installed option is eRamRom, this object
contains the size, in bytes, of the random access memory. If
the type of the installed option is eInputPHD, the capacity
indicates the number of input trays supported by the installed
option. If the type of the installed option is eOutputPHD, the
capacity indicates the number of output bins supported by the
installed option. If the type of the installed option is
eIOCard, the capacity indicates the number of logical I/O ports
supported by the I/O card.
Additional information:
Returns an indication of the capacity of the
installed option in bytes. This object is not
supported unless the SIMM1-TYPE type is
eVolatileRandomAccessMemory, eRamRom, or eFlashMemory.
For eRamRom only the size of the Ram portion of the SIMM
is returned."
::= { simm1 5 }
simm1-bank1-type OBJECT-TYPE
SYNTAX INTEGER {
eEmpty(1),
eUnknown(2),
eUnSupported(3),
eReadOnlyMemory(4),
eVolatileRandomAccessMemory(5),
eFlashMemory(7),
eRamRom(9)
}
ACCESS read-only
STATUS optional
DESCRIPTION
"Returns an indication of the type of option installed in Bank 1
of SIMM slot 1. See SIMM1-TYPE for a description.
Additional information:
This object is used for describing the type
of DIMM banks. Each physical DIMM slot has up to 2 banks."
::= { simm1-bank1 1 }
simm1-bank1-capacity OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION
"Returns an indication of the capacity of Bank 1 of the SIMM
installed in SIMM slot 1. See SIMM1-CAPACITY for a
description.
Additional information:
Returns an indication of the capacity of the
installed bank option in bytes. This object is not
supported unless the SIMM1-BANK1-TYPE type is
eReadOnlyMemory, eFlashMemory, eEDORandomAccessMemory,
eSDRandomAccessMemory, eSRandomAccessMemory,
or eFPMRandomAccessMemory."
::= { simm1-bank1 2 }
simm1-bank2-type OBJECT-TYPE
SYNTAX INTEGER {
eEmpty(1),
eUnknown(2),
eUnSupported(3),
eReadOnlyMemory(4),
eVolatileRandomAccessMemory(5),
eFlashMemory(7),
eRamRom(9)
}
ACCESS read-only
STATUS optional
DESCRIPTION
"Returns an indication of the type of option installed in Bank 2
of SIMM slot 1. See SIMM1-TYPE for a description.
Additional information:
This object is used for describing the type
of DIMM banks. Each physical DIMM slot has up to 2 banks."
::= { simm1-bank2 1 }
simm1-bank2-capacity OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION
"Returns an indication of the capacity of Bank 2 of the SIMM
installed in SIMM slot 1. See SIMM1-CAPACITY for a
description.
Additional information:
Returns an indication of the capacity of the
installed bank option in bytes. This object is not
supported unless the SIMM1-BANK2-TYPE type is
eReadOnlyMemory, eFlashMemory, eEDORandomAccessMemory,
eSDRandomAccessMemory, eSRandomAccessMemory,
or eFPMRandomAccessMemory."
::= { simm1-bank2 2 }
simm2-type OBJECT-TYPE
SYNTAX INTEGER {
eEmpty(1),
eUnknown(2),
eUnSupported(3),
eReadOnlyMemory(4),
eVolatileRandomAccessMemory(5),
eFlashMemory(7),
eRamRom(9)
}
ACCESS read-only
STATUS optional
DESCRIPTION
"Returns an indication of the type of option installed in SIMM
slot 2. See SIMM1-TYPE for a description.
Additional information:
This object is used for describing DIMMs instead
of SIMMs on LaserJet 8150. eRamRom is used to denote LaserJet 8150's combo simm."
::= { simm2 4 }
simm2-capacity OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION
"Returns an indication of the capacity of the SIMM installed in
SIMM slot 2. See SIMM1-CAPACITY for a description.
Additional information:
This object is used for describing DIMMs instead
of SIMMs on LaserJet 8150. Returns an indication of the capacity of the
installed option in bytes. This object is not
supported unless the SIMM2-TYPE type is
eVolatileRandomAccessMemory, eRamRom, or eFlashMemory.
For eRamRom only the size of the Ram portion of the
SIMM is returned."
::= { simm2 5 }
simm2-bank1-type OBJECT-TYPE
SYNTAX INTEGER {
eEmpty(1),
eUnknown(2),
eUnSupported(3),
eReadOnlyMemory(4),
eVolatileRandomAccessMemory(5),
eFlashMemory(7),
eRamRom(9)
}
ACCESS read-only
STATUS optional
DESCRIPTION
"Returns an indication of the type of option installed in Bank 1
of SIMM slot 2. See SIMM1-TYPE for a description.
Additional information:
This object is used for describing the type
of DIMM banks. Each physical DIMM slot has up to 2 banks."
::= { simm2-bank1 1 }
simm2-bank1-capacity OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION
"Returns an indication of the capacity of Bank 1 of the SIMM
installed in SIMM slot 2. See SIMM1-CAPACITY for a
description.
Additional information:
Returns an indication of the capacity of the
installed bank option in bytes. This object is not
supported unless the SIMM2-BANK1-TYPE type is
eReadOnlyMemory, eFlashMemory, eEDORandomAccessMemory,
eSDRandomAccessMemory, eSRandomAccessMemory,
or eFPMRandomAccessMemory."
::= { simm2-bank1 2 }
simm2-bank2-type OBJECT-TYPE
SYNTAX INTEGER {
eEmpty(1),
eUnknown(2),
eUnSupported(3),
eReadOnlyMemory(4),
eVolatileRandomAccessMemory(5),
eFlashMemory(7),
eRamRom(9)
}
ACCESS read-only
STATUS optional
DESCRIPTION
"Returns an indication of the type of option installed in Bank 2
of SIMM slot 2. See SIMM1-TYPE for a description.
Additional information:
This object is used for describing the type
of DIMM banks. Each physical DIMM slot has up to 2 banks."
::= { simm2-bank2 1 }
simm2-bank2-capacity OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION
"Returns an indication of the capacity of Bank 2 of the SIMM
installed in SIMM slot 2. See SIMM1-CAPACITY for a
description.
Additional information:
Returns an indication of the capacity of the
installed bank option in bytes. This object is not
supported unless the SIMM2-BANK2-TYPE type is
eReadOnlyMemory, eFlashMemory, eEDORandomAccessMemory,
eSDRandomAccessMemory, eSRandomAccessMemory,
or eFPMRandomAccessMemory."
::= { simm2-bank2 2 }
simm3-type OBJECT-TYPE
SYNTAX INTEGER {
eEmpty(1),
eUnknown(2),
eUnSupported(3),
eReadOnlyMemory(4),
eVolatileRandomAccessMemory(5),
eFlashMemory(7),
eRamRom(9)
}
ACCESS read-only
STATUS optional
DESCRIPTION
"Returns an indication of the type of option installed in SIMM
slot 3. See SIMM1-TYPE for a description."
::= { simm3 4 }
simm3-capacity OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION
"Returns an indication of the capacity of the SIMM installed in
SIMM slot 3. See SIMM1-CAPACITY for a description.
Additional information:
This object is used for describing DIMMs instead
of SIMMs on LaserJet 8150. Returns an indication of the capacity of the
installed option in bytes. This object is not
supported unless the SIMM3-TYPE type is
eVolatileRandomAccessMemory, eRamRom, or eFlashMemory.
For eRamRom only the size of the Ram portion of the
simm is returned."
::= { simm3 5 }
simm3-bank1-type OBJECT-TYPE
SYNTAX INTEGER {
eEmpty(1),
eUnknown(2),
eUnSupported(3),
eReadOnlyMemory(4),
eVolatileRandomAccessMemory(5),
eFlashMemory(7),
eRamRom(9)
}
ACCESS read-only
STATUS optional
DESCRIPTION
"Returns an indication of the type of option installed in Bank 1
of SIMM slot 3. See SIMM1-TYPE for a description.
Additional information:
This object is used for describing the type
of DIMM banks. Each physical DIMM slot has up to 2 banks."
::= { simm3-bank1 1 }
simm3-bank1-capacity OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION
"Returns an indication of the capacity of Bank 1 of the SIMM
installed in SIMM slot 3. See SIMM1-CAPACITY for a
description.
Additional information:
Returns an indication of the capacity of the
installed bank option in bytes. This object is not
supported unless the SIMM3-BANK1-TYPE type is
eReadOnlyMemory, eFlashMemory, eEDORandomAccessMemory,
eSDRandomAccessMemory, eSRandomAccessMemory,
or eFPMRandomAccessMemory."
::= { simm3-bank1 2 }
simm3-bank2-type OBJECT-TYPE
SYNTAX INTEGER {
eEmpty(1),
eUnknown(2),
eUnSupported(3),
eReadOnlyMemory(4),
eVolatileRandomAccessMemory(5),
eFlashMemory(7),
eRamRom(9)
}
ACCESS read-only
STATUS optional
DESCRIPTION
"Returns an indication of the type of option installed in Bank 2
of SIMM slot 3. See SIMM1-TYPE for a description.
Additional information:
This object is used for describing the type
of DIMM banks. Each physical DIMM slot has up to 2 banks."
::= { simm3-bank2 1 }
simm3-bank2-capacity OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION
"Returns an indication of the capacity of Bank 2 of the SIMM
installed in SIMM slot 3. See SIMM1-CAPACITY for a
description.
Additional information:
Returns an indication of the capacity of the
installed bank option in bytes. This object is not
supported unless the SIMM3-BANK2-TYPE type is
eReadOnlyMemory, eFlashMemory, eEDORandomAccessMemory,
eSDRandomAccessMemory, eSRandomAccessMemory,
or eFPMRandomAccessMemory."
::= { simm3-bank2 2 }
cancel-job OBJECT-TYPE
SYNTAX INTEGER(0..32767)
ACCESS write-only
STATUS optional
DESCRIPTION
"Cancels the print job whose ID matches the value written to the
CANCEL-JOB object. The host first learns the job ID using the
CURRENT-JOB-PARSING-ID command. If the printer has completely
processed the job, the printer responds with
<badValue>. If the value of the
CURRENT-JOB-PARSING-ID is smaller than the value written to the
CANCEL-JOB object, then the printer responds with
<badValue>. When read, returns the value
of the last job ID what was canceled, or -1 to indicate no job
has been canceled.
Additional information:
If the value written matches the ID of a job that is
currently being canceled (for any reason),
the printer responds with <noError>.
LaserJet 8150 uses job ID's in the range of 0..32767.
Because the ID number can wrap to zero,
CURRENT-JOB-PARSING-ID may be smaller than the value
written to this object; when this occurs, no error
will result as long as the ID is for a currently
processing job. This object is write only, so the
comment in the general description stating the
job ID or -1 will be returned on a read does not
apply."
::= { settings-job 2 }
os-execute-file OBJECT-TYPE
SYNTAX DisplayString
ACCESS write-only
STATUS optional
DESCRIPTION
"This object's input is a null-terminated string representing a
fully-qualified path name for an executable file. This object
causes the file to be executed by the OS.
Additional information:
This object's input is a null-terminated string of two or
more whitespace-separated tokens. The first token is a path
to a directory to make the current working directory. The
second token is a path to an executable file to be executed.
Any remaining whitespace-separated tokens are optional and
will be passed as parameters to the executable. The paths
to the directory and executable can be either PJL style
(e.g., 1:\app\example) or UNIX-style (e.g.,
/hpmnt/dsk_ide1a/app/example). The executable is run in
a separate process."
::= { operating-system 1 }
form-feed OBJECT-TYPE
SYNTAX INTEGER {
eInitiateAction(1)
}
ACCESS write-only
STATUS optional
DESCRIPTION
"Instructs the PDL processing sub-system to finishing processing
the current page of the current job. Form feed is also known as
close page or eject page. If the PDL processing sub-system is
in a FORM-FEED-NEEDED state, this causes the device to flush or
finish processing the current page of the current job. If the
device is not in the FORM-FEED-NEEDED state, an
<genErr> will occur."
::= { settings-pdl 5 }
form-feed-needed OBJECT-TYPE
SYNTAX INTEGER {
eFalse(1),
eTrue(2)
}
ACCESS read-only
STATUS optional
DESCRIPTION
"Indicates if the PDL processing sub-system has made marks on
the current page and the source subsystem has been idle for a
device specific amount of time.
Additional information:
LaserJet 8150 will set this object to eTrue when it
has made marks on the current page, the IO-TIMEOUT has
expired while PCL was running in `backward-compatibility
mode' (which is caused by jobs consisting purely of PCL
data with no prepended PJL commands), and no data is pending
on another I/O. Once it is set to eTrue, more data on the
same I/O will cause this object to be set to eFalse, until
the above conditions are met again."
::= { status-pdl 2 }
error-log-clear OBJECT-TYPE
SYNTAX INTEGER {
eClearErrorLog(1)
}
ACCESS write-only
STATUS optional
DESCRIPTION
"Setting this object clears all the entries in the error log
sub-tree.
Additional information:
Setting this object removes all errors that have been
stored in the printer's non-volatile memory."
::= { status-system 38 }
clearable-warning OBJECT-TYPE
SYNTAX INTEGER {
eOn(2),
eJob(3)
}
ACCESS read-write
STATUS optional
DESCRIPTION
"Returns or controls how the device will track clearable
warnings. A clearable warning indicates a transient event in
the device. The device will continue after the transient event
occurs. If CLEARABLE-WARNING is eOff, the device does not track
clearable warnings. If CLEARABLE-WARNING is eOn, all clearable
warnings will be tracked until cleared (acknowledged). If
CLEARABLE-WARNING is eJob, a clearable warning generated due to
an event that occurs because of the print job being processed
will be automatically cleared when the device has finished
processing the job. Example clearable warning events include
the device altering resolution or page protection due to memory
constraints. The POS will document what transient events are
treated as clearable warnings.
Additional information:
If set to eOn, the warning is displayed until the GO key
is pressed or the CONTINUE object is set.
If set to eJob, the warning is displayed until the end of the job in which
it was generated."
::= { settings-job 1 }
error1-time-stamp OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION
"Contains some sort of time stamp indicating when error 1
occurred. Example time stamps include the actual time the error
occurred (in seconds since Jan. 1, 1970), and the total engine
page count. The device POS documents the meaning of the time
stamp.
Additional information:
This item contains the engine
page count when the error occurred.
If there is currently no error entry for this object, a '0' will be returned.
Note that '0' may also be returned when there is a valid error, but a current
page count was unavailable. If ERROR1-CODE object also returns '0', then
an error has not yet been logged for this object.
See ERROR1-CODE for an explanation of the order used for storing errors."
::= { error1 1 }
error1-code OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION
"Contains a device specific error code. Each device POS should
list what errors are logged to the error log and the meaning of
each supported error code value.
Additional information:
Returns a device specific error code.
If the error code returned is '0', then the printer has not yet logged an
error for this object.
When the maximum number of errors is reached (30 on LaserJet printers), and
a new error occurs, the error in ERROR1-CODE will be replaced by the
one in ERROR2-CODE, and so on until the last error object will be given
the value of the new error.
The error number is returned in the upper 16 bits.
If it is 68, 69, 79, or 80, then the sub code is returned in the lower
16 bits (eg. 68 001C, where the subcode is already a hexadecimal value).
If the error number is any other number, then the 1st sub code (XX)
will be in bits 15-8 and the 2nd sub code (YY) will be in bits 7-0 (eg.
55.04.02) where XX=04 and YY=02).
Example: If the error is 68 001A, then the value returned will be 4456474.
To break it down: 4456474 = 0x0044001A
The upper 16 bits: 0x0044 = 68
The lower 16 bits: 0x001A = 001A
Which is the error: 68 001A
Example: If the error is 55.04.241, then the error code will be 3605745.
To break it down: 3605745 = 0x003704F1
The upper 16 bits: 0x0037 = 55
The upper byte of the lower 16 bits: 0x04 = 04
The lower byte of the lower 16 bits: 0xF1 = 241
Which is the error: 55.04.241"
::= { error1 2 }
error2-time-stamp OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION
"Contains some sort of time stamp indicating when error 2
occurred. Example time stamps include the actual time the error
occurred (in seconds since Jan. 1, 1970), and the total engine
page count. The device POS documents the meaning of the time
stamp.
Additional information:
See ERROR1-TIME-STAMP."
::= { error2 1 }
error2-code OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION
"Contains a device specific error code. Each device POS should
list what errors are logged to the error log and the meaning of
each supported error code value.
Additional information:
See ERROR1-CODE."
::= { error2 2 }
error3-time-stamp OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION
"Contains some sort of time stamp indicating when error 3
occurred. Example time stamps include the actual time the error
occurred (in seconds since Jan. 1, 1970), and the total engine
page count. The device POS documents the meaning of the time
stamp.
Additional information:
See ERROR1-TIME-STAMP."
::= { error3 1 }
error3-code OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION
"Contains a device specific error code. Each device POS should
list what errors are logged to the error log and the meaning of
each supported error code value.
Additional information:
See ERROR1-CODE."
::= { error3 2 }
error4-time-stamp OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION
"Contains some sort of time stamp indicating when error 4
occurred. Example time stamps include the actual time the error
occurred (in seconds since Jan. 1, 1970), and the total engine
page count. The device POS documents the meaning of the time
stamp.
Additional information:
See ERROR1-TIME-STAMP."
::= { error4 1 }
error4-code OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION
"Contains a device specific error code. Each device POS should
list what errors are logged to the error log and the meaning of
each supported error code value.
Additional information:
See ERROR1-CODE."
::= { error4 2 }
error5-time-stamp OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION
"Contains some sort of time stamp indicating when error 5
occurred. Example time stamps include the actual time the error
occurred (in seconds since Jan. 1, 1970), and the total engine
page count. The device POS documents the meaning of the time
stamp.
Additional information:
See ERROR1-TIME-STAMP."
::= { error5 1 }
error5-code OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION
"Contains a device specific error code. Each device POS should
list what errors are logged to the error log and the meaning of
each supported error code value.
Additional information:
See ERROR1-CODE."
::= { error5 2 }
error6-time-stamp OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION
"Contains some sort of time stamp indicating when error 6
occurred. Example time stamps include the actual time the error
occurred (in seconds since Jan. 1, 1970), and the total engine
page count. The device POS documents the meaning of the time
stamp.
Additional information:
See ERROR1-TIME-STAMP."
::= { error6 1 }
error6-code OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION
"Contains a device specific error code. Each device POS should
list what errors are logged to the error log and the meaning of
each supported error code value.
Additional information:
See ERROR1-CODE."
::= { error6 2 }
error7-time-stamp OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION
"Contains some sort of time stamp indicating when error 7
occurred. Example time stamps include the actual time the error
occurred (in seconds since Jan. 1, 1970), and the total engine
page count. The device POS documents the meaning of the time
stamp.
Additional information:
See ERROR1-TIME-STAMP."
::= { error7 1 }
error7-code OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION
"Contains a device specific error code. Each device POS should
list what errors are logged to the error log and the meaning of
each supported error code value.
Additional information:
See ERROR1-CODE."
::= { error7 2 }
error8-time-stamp OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION
"Contains some sort of time stamp indicating when error 8
occurred. Example time stamps include the actual time the error
occurred (in seconds since Jan. 1, 1970), and the total engine
page count. The device POS documents the meaning of the time
stamp.
Additional information:
See ERROR1-TIME-STAMP."
::= { error8 1 }
error8-code OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION
"Contains a device specific error code. Each device POS should
list what errors are logged to the error log and the meaning of
each supported error code value.
Additional information:
See ERROR1-CODE."
::= { error8 2 }
error9-time-stamp OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION
"Contains some sort of time stamp indicating when error 9
occurred. Example time stamps include the actual time the error
occurred (in seconds since Jan. 1, 1970), and the total engine
page count. The device POS documents the meaning of the time
stamp.
Additional information:
See ERROR1-TIME-STAMP."
::= { error9 1 }
error9-code OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION
"Contains a device specific error code. Each device POS should
list what errors are logged to the error log and the meaning of
each supported error code value.
Additional information:
See ERROR1-CODE."
::= { error9 2 }
error10-time-stamp OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION
"Contains some sort of time stamp indicating when error 10
occurred. Example time stamps include the actual time the error
occurred (in seconds since Jan. 1, 1970), and the total engine
page count. The device POS documents the meaning of the time
stamp.
Additional information:
See ERROR1-TIME-STAMP."
::= { error10 1 }
error10-code OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION
"Contains a device specific error code. Each device POS should
list what errors are logged to the error log and the meaning of
each supported error code value.
Additional information:
See ERROR1-CODE."
::= { error10 2 }
error11-time-stamp OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION
"Contains some sort of time stamp indicating when error 11
occurred. Example time stamps include the actual time the error
occurred (in seconds since Jan. 1, 1970), and the total engine
page count. The device POS documents the meaning of the time
stamp.
Additional information:
See ERROR1-TIME-STAMP."
::= { error11 1 }
error11-code OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION
"Contains a device specific error code. Each device POS should
list what errors are logged to the error log and the meaning of
each supported error code value.
Additional information:
See ERROR1-CODE."
::= { error11 2 }
error12-time-stamp OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION
"Contains some sort of time stamp indicating when error 12
occurred. Example time stamps include the actual time the error
occurred (in seconds since Jan. 1, 1970), and the total engine
page count. The device POS documents the meaning of the time
stamp.
Additional information:
See ERROR1-TIME-STAMP."
::= { error12 1 }
error12-code OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION
"Contains a device specific error code. Each device POS should
list what errors are logged to the error log and the meaning of
each supported error code value.
Additional information:
See ERROR1-CODE."
::= { error12 2 }
error13-time-stamp OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION
"Contains some sort of time stamp indicating when error 13
occurred. Example time stamps include the actual time the error
occurred (in seconds since Jan. 1, 1970), and the total engine
page count. The device POS documents the meaning of the time
stamp.
Additional information:
See ERROR1-TIME-STAMP."
::= { error13 1 }
error13-code OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION
"Contains a device specific error code. Each device POS should
list what errors are logged to the error log and the meaning of
each supported error code value.
Additional information:
See ERROR1-CODE."
::= { error13 2 }
error14-time-stamp OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION
"Contains some sort of time stamp indicating when error 14
occurred. Example time stamps include the actual time the error
occurred (in seconds since Jan. 1, 1970), and the total engine
page count. The device POS documents the meaning of the time
stamp.
Additional information:
See ERROR1-TIME-STAMP."
::= { error14 1 }
error14-code OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION
"Contains a device specific error code. Each device POS should
list what errors are logged to the error log and the meaning of
each supported error code value.
Additional information:
See ERROR1-CODE."
::= { error14 2 }
error15-time-stamp OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION
"Contains some sort of time stamp indicating when error 15
occurred. Example time stamps include the actual time the error
occurred (in seconds since Jan. 1, 1970), and the total engine
page count. The device POS documents the meaning of the time
stamp.
Additional information:
See ERROR1-TIME-STAMP."
::= { error15 1 }
error15-code OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION
"Contains a device specific error code. Each device POS should
list what errors are logged to the error log and the meaning of
each supported error code value.
Additional information:
See ERROR1-CODE."
::= { error15 2 }
error16-time-stamp OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION
"Contains some sort of time stamp indicating when error 16
occurred. Example time stamps include the actual time the error
occurred (in seconds since Jan. 1, 1970), and the total engine
page count. The device POS documents the meaning of the time
stamp.
Additional information:
See ERROR1-TIME-STAMP."
::= { error16 1 }
error16-code OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION
"Contains a device specific error code. Each device POS should
list what errors are logged to the error log and the meaning of
each supported error code value.
Additional information:
See ERROR1-CODE."
::= { error16 2 }
error17-time-stamp OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION
"Contains some sort of time stamp indicating when error 17
occurred. Example time stamps include the actual time the error
occurred (in seconds since Jan. 1, 1970), and the total engine
page count. The device POS documents the meaning of the time
stamp.
Additional information:
See ERROR1-TIME-STAMP."
::= { error17 1 }
error17-code OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION
"Contains a device specific error code. Each device POS should
list what errors are logged to the error log and the meaning of
each supported error code value.
Additional information:
See ERROR1-CODE."
::= { error17 2 }
error18-time-stamp OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION
"Contains some sort of time stamp indicating when error 18
occurred. Example time stamps include the actual time the error
occurred (in seconds since Jan. 1, 1970), and the total engine
page count. The device POS documents the meaning of the time
stamp.
Additional information:
See ERROR1-TIME-STAMP."
::= { error18 1 }
error18-code OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION
"Contains a device specific error code. Each device POS should
list what errors are logged to the error log and the meaning of
each supported error code value.
Additional information:
See ERROR1-CODE."
::= { error18 2 }
error19-time-stamp OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION
"Contains some sort of time stamp indicating when error 19
occurred. Example time stamps include the actual time the error
occurred (in seconds since Jan. 1, 1970), and the total engine
page count. The device POS documents the meaning of the time
stamp.
Additional information:
See ERROR1-TIME-STAMP."
::= { error19 1 }
error19-code OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION
"Contains a device specific error code. Each device POS should
list what errors are logged to the error log and the meaning of
each supported error code value.
Additional information:
See ERROR1-CODE."
::= { error19 2 }
error20-time-stamp OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION
"Contains some sort of time stamp indicating when error 20
occurred. Example time stamps include the actual time the error
occurred (in seconds since Jan. 1, 1970), and the total engine
page count. The device POS documents the meaning of the time
stamp.
Additional information:
See ERROR1-TIME-STAMP."
::= { error20 1 }
error20-code OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION
"Contains a device specific error code. Each device POS should
list what errors are logged to the error log and the meaning of
each supported error code value.
Additional information:
See ERROR1-CODE."
::= { error20 2 }
error21-time-stamp OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION
"Contains some sort of time stamp indicating when error 21
occurred. Example time stamps include the actual time the error
occurred (in seconds since Jan. 1, 1970), and the total engine
page count. The device POS documents the meaning of the time
stamp.
Additional information:
See ERROR1-TIME-STAMP."
::= { error21 1 }
error21-code OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION
"Contains a device specific error code. Each device POS should
list what errors are logged to the error log and the meaning of
each supported error code value.
Additional information:
See ERROR1-CODE."
::= { error21 2 }
error22-time-stamp OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION
"Contains some sort of time stamp indicating when error 22
occurred. Example time stamps include the actual time the error
occurred (in seconds since Jan. 1, 1970), and the total engine
page count. The device POS documents the meaning of the time
stamp.
Additional information:
See ERROR1-TIME-STAMP."
::= { error22 1 }
error22-code OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION
"Contains a device specific error code. Each device POS should
list what errors are logged to the error log and the meaning of
each supported error code value.
Additional information:
See ERROR1-CODE."
::= { error22 2 }
error23-time-stamp OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION
"Contains some sort of time stamp indicating when error 23
occurred. Example time stamps include the actual time the error
occurred (in seconds since Jan. 1, 1970), and the total engine
page count. The device POS documents the meaning of the time
stamp.
Additional information:
See ERROR1-TIME-STAMP."
::= { error23 1 }
error23-code OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION
"Contains a device specific error code. Each device POS should
list what errors are logged to the error log and the meaning of
each supported error code value.
Additional information:
See ERROR1-CODE."
::= { error23 2 }
error24-time-stamp OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION
"Contains some sort of time stamp indicating when error 24
occurred. Example time stamps include the actual time the error
occurred (in seconds since Jan. 1, 1970), and the total engine
page count. The device POS documents the meaning of the time
stamp.
Additional information:
See ERROR1-TIME-STAMP."
::= { error24 1 }
error24-code OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION
"Contains a device specific error code. Each device POS should
list what errors are logged to the error log and the meaning of
each supported error code value.
Additional information:
See ERROR1-CODE."
::= { error24 2 }
error25-time-stamp OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION
"Contains some sort of time stamp indicating when error 25
occurred. Example time stamps include the actual time the error
occurred (in seconds since Jan. 1, 1970), and the total engine
page count. The device POS documents the meaning of the time
stamp.
Additional information:
See ERROR1-TIME-STAMP."
::= { error25 1 }
error25-code OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION
"Contains a device specific error code. Each device POS should
list what errors are logged to the error log and the meaning of
each supported error code value.
Additional information:
See ERROR1-CODE."
::= { error25 2 }
error26-time-stamp OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION
"Contains some sort of time stamp indicating when error 26
occurred. Example time stamps include the actual time the error
occurred (in seconds since Jan. 1, 1970), and the total engine
page count. The device POS documents the meaning of the time
stamp.
Additional information:
See ERROR1-TIME-STAMP."
::= { error26 1 }
error26-code OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION
"Contains a device specific error code. Each device POS should
list what errors are logged to the error log and the meaning of
each supported error code value.
Additional information:
See ERROR1-CODE."
::= { error26 2 }
error27-time-stamp OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION
"Contains some sort of time stamp indicating when error 27
occurred. Example time stamps include the actual time the error
occurred (in seconds since Jan. 1, 1970), and the total engine
page count. The device POS documents the meaning of the time
stamp.
Additional information:
See ERROR1-TIME-STAMP."
::= { error27 1 }
error27-code OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION
"Contains a device specific error code. Each device POS should
list what errors are logged to the error log and the meaning of
each supported error code value.
Additional information:
See ERROR1-CODE."
::= { error27 2 }
error28-time-stamp OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION
"Contains some sort of time stamp indicating when error 28
occurred. Example time stamps include the actual time the error
occurred (in seconds since Jan. 1, 1970), and the total engine
page count. The device POS documents the meaning of the time
stamp.
Additional information:
See ERROR1-TIME-STAMP."
::= { error28 1 }
error28-code OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION
"Contains a device specific error code. Each device POS should
list what errors are logged to the error log and the meaning of
each supported error code value.
Additional information:
See ERROR1-CODE."
::= { error28 2 }
error29-time-stamp OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION
"Contains some sort of time stamp indicating when error 29
occurred. Example time stamps include the actual time the error
occurred (in seconds since Jan. 1, 1970), and the total engine
page count. The device POS documents the meaning of the time
stamp.
Additional information:
See ERROR1-TIME-STAMP."
::= { error29 1 }
error29-code OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION
"Contains a device specific error code. Each device POS should
list what errors are logged to the error log and the meaning of
each supported error code value.
Additional information:
See ERROR1-CODE."
::= { error29 2 }
error30-time-stamp OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION
"Contains some sort of time stamp indicating when error 30
occurred. Example time stamps include the actual time the error
occurred (in seconds since Jan. 1, 1970), and the total engine
page count. The device POS documents the meaning of the time
stamp.
Additional information:
See ERROR1-TIME-STAMP."
::= { error30 1 }
error30-code OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION
"Contains a device specific error code. Each device POS should
list what errors are logged to the error log and the meaning of
each supported error code value.
Additional information:
See ERROR1-CODE."
::= { error30 2 }
error31-time-stamp OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION
"Contains some sort of time stamp indicating when error 31
occurred. Example time stamps include the actual time the error
occurred (in seconds since Jan. 1, 1970), and the total engine
page count. The device POS documents the meaning of the time
stamp.
Additional information:
See ERROR1-TIME-STAMP."
::= { error31 1 }
error31-code OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION
"Contains a device specific error code. Each device POS should
list what errors are logged to the error log and the meaning of
each supported error code value.
Additional information:
See ERROR1-CODE."
::= { error31 2 }
error32-time-stamp OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION
"Contains some sort of time stamp indicating when error 32
occurred. Example time stamps include the actual time the error
occurred (in seconds since Jan. 1, 1970), and the total engine
page count. The device POS documents the meaning of the time
stamp.
Additional information:
See ERROR1-TIME-STAMP."
::= { error32 1 }
error32-code OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION
"Contains a device specific error code. Each device POS should
list what errors are logged to the error log and the meaning of
each supported error code value.
Additional information:
See ERROR1-CODE."
::= { error32 2 }
error33-time-stamp OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION
"Contains some sort of time stamp indicating when error 33
occurred. Example time stamps include the actual time the error
occurred (in seconds since Jan. 1, 1970), and the total engine
page count. The device POS documents the meaning of the time
stamp.
Additional information:
See ERROR1-TIME-STAMP."
::= { error33 1 }
error33-code OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION
"Contains a device specific error code. Each device POS should
list what errors are logged to the error log and the meaning of
each supported error code value.
Additional information:
See ERROR1-CODE."
::= { error33 2 }
error34-time-stamp OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION
"Contains some sort of time stamp indicating when error 34
occurred. Example time stamps include the actual time the error
occurred (in seconds since Jan. 1, 1970), and the total engine
page count. The device POS documents the meaning of the time
stamp.
Additional information:
See ERROR1-TIME-STAMP."
::= { error34 1 }
error34-code OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION
"Contains a device specific error code. Each device POS should
list what errors are logged to the error log and the meaning of
each supported error code value.
Additional information:
See ERROR1-CODE."
::= { error34 2 }
error35-time-stamp OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION
"Contains some sort of time stamp indicating when error 35
occurred. Example time stamps include the actual time the error
occurred (in seconds since Jan. 1, 1970), and the total engine
page count. The device POS documents the meaning of the time
stamp.
Additional information:
See ERROR1-TIME-STAMP."
::= { error35 1 }
error35-code OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION
"Contains a device specific error code. Each device POS should
list what errors are logged to the error log and the meaning of
each supported error code value.
Additional information:
See ERROR1-CODE."
::= { error35 2 }
error36-time-stamp OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION
"Contains some sort of time stamp indicating when error 36
occurred. Example time stamps include the actual time the error
occurred (in seconds since Jan. 1, 1970), and the total engine
page count. The device POS documents the meaning of the time
stamp.
Additional information:
See ERROR1-TIME-STAMP."
::= { error36 1 }
error36-code OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION
"Contains a device specific error code. Each device POS should
list what errors are logged to the error log and the meaning of
each supported error code value.
Additional information:
See ERROR1-CODE."
::= { error36 2 }
error37-time-stamp OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION
"Contains some sort of time stamp indicating when error 37
occurred. Example time stamps include the actual time the error
occurred (in seconds since Jan. 1, 1970), and the total engine
page count. The device POS documents the meaning of the time
stamp.
Additional information:
See ERROR1-TIME-STAMP."
::= { error37 1 }
error37-code OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION
"Contains a device specific error code. Each device POS should
list what errors are logged to the error log and the meaning of
each supported error code value.
Additional information:
See ERROR1-CODE."
::= { error37 2 }
error38-time-stamp OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION
"Contains some sort of time stamp indicating when error 38
occurred. Example time stamps include the actual time the error
occurred (in seconds since Jan. 1, 1970), and the total engine
page count. The device POS documents the meaning of the time
stamp.
Additional information:
See ERROR1-TIME-STAMP."
::= { error38 1 }
error38-code OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION
"Contains a device specific error code. Each device POS should
list what errors are logged to the error log and the meaning of
each supported error code value.
Additional information:
See ERROR1-CODE."
::= { error38 2 }
error39-time-stamp OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION
"Contains some sort of time stamp indicating when error 39
occurred. Example time stamps include the actual time the error
occurred (in seconds since Jan. 1, 1970), and the total engine
page count. The device POS documents the meaning of the time
stamp.
Additional information:
See ERROR1-TIME-STAMP."
::= { error39 1 }
error39-code OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION
"Contains a device specific error code. Each device POS should
list what errors are logged to the error log and the meaning of
each supported error code value.
Additional information:
See ERROR1-CODE."
::= { error39 2 }
error40-time-stamp OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION
"Contains some sort of time stamp indicating when error 40
occurred. Example time stamps include the actual time the error
occurred (in seconds since Jan. 1, 1970), and the total engine
page count. The device POS documents the meaning of the time
stamp.
Additional information:
See ERROR1-TIME-STAMP."
::= { error40 1 }
error40-code OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION
"Contains a device specific error code. Each device POS should
list what errors are logged to the error log and the meaning of
each supported error code value.
Additional information:
See ERROR1-CODE."
::= { error40 2 }
error41-time-stamp OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION
"Contains some sort of time stamp indicating when error 41
occurred. Example time stamps include the actual time the error
occurred (in seconds since Jan. 1, 1970), and the total engine
page count. The device POS documents the meaning of the time
stamp.
Additional information:
See ERROR1-TIME-STAMP."
::= { error41 1 }
error41-code OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION
"Contains a device specific error code. Each device POS should
list what errors are logged to the error log and the meaning of
each supported error code value.
Additional information:
See ERROR1-CODE."
::= { error41 2 }
error42-time-stamp OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION
"Contains some sort of time stamp indicating when error 42
occurred. Example time stamps include the actual time the error
occurred (in seconds since Jan. 1, 1970), and the total engine
page count. The device POS documents the meaning of the time
stamp.
Additional information:
See ERROR1-TIME-STAMP."
::= { error42 1 }
error42-code OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION
"Contains a device specific error code. Each device POS should
list what errors are logged to the error log and the meaning of
each supported error code value.
Additional information:
See ERROR1-CODE."
::= { error42 2 }
error43-time-stamp OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION
"Contains some sort of time stamp indicating when error 43
occurred. Example time stamps include the actual time the error
occurred (in seconds since Jan. 1, 1970), and the total engine
page count. The device POS documents the meaning of the time
stamp.
Additional information:
See ERROR1-TIME-STAMP."
::= { error43 1 }
error43-code OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION
"Contains a device specific error code. Each device POS should
list what errors are logged to the error log and the meaning of
each supported error code value.
Additional information:
See ERROR1-CODE."
::= { error43 2 }
error44-time-stamp OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION
"Contains some sort of time stamp indicating when error 44
occurred. Example time stamps include the actual time the error
occurred (in seconds since Jan. 1, 1970), and the total engine
page count. The device POS documents the meaning of the time
stamp.
Additional information:
See ERROR1-TIME-STAMP."
::= { error44 1 }
error44-code OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION
"Contains a device specific error code. Each device POS should
list what errors are logged to the error log and the meaning of
each supported error code value.
Additional information:
See ERROR1-CODE."
::= { error44 2 }
error45-time-stamp OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION
"Contains some sort of time stamp indicating when error 45
occurred. Example time stamps include the actual time the error
occurred (in seconds since Jan. 1, 1970), and the total engine
page count. The device POS documents the meaning of the time
stamp.
Additional information:
See ERROR1-TIME-STAMP."
::= { error45 1 }
error45-code OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION
"Contains a device specific error code. Each device POS should
list what errors are logged to the error log and the meaning of
each supported error code value.
Additional information:
See ERROR1-CODE."
::= { error45 2 }
error46-time-stamp OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION
"Contains some sort of time stamp indicating when error 46
occurred. Example time stamps include the actual time the error
occurred (in seconds since Jan. 1, 1970), and the total engine
page count. The device POS documents the meaning of the time
stamp.
Additional information:
See ERROR1-TIME-STAMP."
::= { error46 1 }
error46-code OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION
"Contains a device specific error code. Each device POS should
list what errors are logged to the error log and the meaning of
each supported error code value.
Additional information:
See ERROR1-CODE."
::= { error46 2 }
error47-time-stamp OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION
"Contains some sort of time stamp indicating when error 47
occurred. Example time stamps include the actual time the error
occurred (in seconds since Jan. 1, 1970), and the total engine
page count. The device POS documents the meaning of the time
stamp.
Additional information:
See ERROR1-TIME-STAMP."
::= { error47 1 }
error47-code OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION
"Contains a device specific error code. Each device POS should
list what errors are logged to the error log and the meaning of
each supported error code value.
Additional information:
See ERROR1-CODE."
::= { error47 2 }
error48-time-stamp OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION
"Contains some sort of time stamp indicating when error 48
occurred. Example time stamps include the actual time the error
occurred (in seconds since Jan. 1, 1970), and the total engine
page count. The device POS documents the meaning of the time
stamp.
Additional information:
See ERROR1-TIME-STAMP."
::= { error48 1 }
error48-code OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION
"Contains a device specific error code. Each device POS should
list what errors are logged to the error log and the meaning of
each supported error code value.
Additional information:
See ERROR1-CODE."
::= { error48 2 }
error49-time-stamp OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION
"Contains some sort of time stamp indicating when error 49
occurred. Example time stamps include the actual time the error
occurred (in seconds since Jan. 1, 1970), and the total engine
page count. The device POS documents the meaning of the time
stamp.
Additional information:
See ERROR1-TIME-STAMP."
::= { error49 1 }
error49-code OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION
"Contains a device specific error code. Each device POS should
list what errors are logged to the error log and the meaning of
each supported error code value.
Additional information:
See ERROR1-CODE."
::= { error49 2 }
error50-time-stamp OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION
"Contains some sort of time stamp indicating when error 50
occurred. Example time stamps include the actual time the error
occurred (in seconds since Jan. 1, 1970), and the total engine
page count. The device POS documents the meaning of the time
stamp.
Additional information:
See ERROR1-TIME-STAMP."
::= { error50 1 }
error50-code OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION
"Contains a device specific error code. Each device POS should
list what errors are logged to the error log and the meaning of
each supported error code value.
Additional information:
See ERROR1-CODE."
::= { error50 2 }
channelprinteralert OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-only
STATUS optional
DESCRIPTION
"Identifies the values of prtAlertIndex, prtAlertSeverityLevel,
prtAlertGroup, prtAlertGroupIndex, prtAlertLocation, and
prtAlertCode for the latest critical evnet in the
prtAlertTable. The binary string is defined as following:
<table>
-----------------------------------------------------
Field | Filed | Description
Offset | Length |
-----------------------------------------------------
0 | 4 | the value of prtAlertIndex
4 | 4 | the value of prtAlertSeverityLevel
8 | 4 | the value of prtAlertGroup
12 | 4 | the value of prtAlertGroupIndex
16 | 4 | the value of prtAlertLocation
20 | 4 | the value of prtAlertCode
------------------------------------------------------
</table>
Each field is in Big Endian style.
Additional information:
This object is used to pass alert information from the
peripheral to the IIO card. The standard printer MIB
contains the following description:
printerAlert TRAP-TYPE
ENTERPRISE printerV1Alert
VARIABLES { prtAlertIndex, prtAlertSeverityLevel, prtAlertGroup,
prtAlertGroupIndex, prtAlertLocation, prtAlertCode }
DESCRIPTION
'This trap is sent whenever a critical event is added to the
prtAlertTable.'
In order to provide this information in the trap packet, the
IIO card enables traps on channelPrinterAlert. When a critical
alert is generated the peripheral fills the appropriate value
into this object and sends it to the card.
This object is a structure which contains 24 bytes of data.
The structure is:
struct structAlertInfo {
sint32 prtAlertIndex;
sint32 prtAlertSeverityLevel;
sint32 prtAlertGroup;
sint32 prtAlertGroupIndex;
sint32 prtAlertLocation;
sint32 prtAlertCode;
} thisAlertData;"
::= { channel 2 }
install-date OBJECT-TYPE
SYNTAX DisplayString (SIZE(13))
ACCESS read-write
STATUS optional
DESCRIPTION
"Identifies the date that the device was installed. The format
of the string is 'YYYYMMDDHHmmZ'. Where:
YYYY is the year.
MM is the month (1-12).
DD is the day (1-31).
HH is the hour of the day (0-23).
mm are the minutes (0-59).
'Z' designates Greenwich Mean Time; if 'Z' not specified,
value is local time.
Device POS must specify the conditions for setting this
object.
Additional information:
Setting the SERVICE-PASSWORD object will
enable setting this object."
::= { status-system 8 }
timestamp OBJECT-TYPE
SYNTAX DisplayString (SIZE(15))
ACCESS write-only
STATUS optional
DESCRIPTION
"Sets the printer's current time in (UTC). The format of the
string is 'YYYYMMDDHHMMSS'. Where
YYYY is the year.
MM is the month (1-12)
DD is the day of the month (1-31)
HH is the hour of the day (0-23)
MM is the minutes (0-59)
SS is the seconds (0-59)
Device POS must specify the conditions for setting this
object."
::= { status-system 13 }
service-id OBJECT-TYPE
SYNTAX DisplayString (SIZE(5))
ACCESS read-write
STATUS optional
DESCRIPTION
"A read of this object will return the current SERVICE ID value
in the printer. The format is 'YYDDD' where:
YY = calendar year - 1990
DDD = (calendar month - 1) * 30 + (calendar day of the
month or 30, if > 30)
A write of this object will only succeed if the
MANUFACTURING-CONTROL PML object has been set with the correct
<<hidden>>. If the write operation is not allowed, this object
will return an <genErr> status.
Additional information:
Setting the SERVICE-PASSWORD object will
enable setting this object."
::= { status-system 19 }
show-address OBJECT-TYPE
SYNTAX INTEGER {
eOff(1),
eAuto(3)
}
ACCESS read-write
STATUS optional
DESCRIPTION
"If this object is set to eAuto, and the device has an IP
address, the IP address of the device will be shown with the
READY message. If this object is set to eOff, the IP address
will not be shown."
::= { display-status 3 }
display-physical-appearance OBJECT-TYPE
SYNTAX INTEGER {
eDisplayIsLight(1),
eDisplayIsNormal(2),
eDisplayIsDark(3)
}
ACCESS read-write
STATUS optional
DESCRIPTION
"This object configures the default brightness setting of the
control panel based on a categorization of the display as
either light, normal, or dark."
::= { display-status 4 }
serial-number OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..10))
ACCESS read-only
STATUS optional
DESCRIPTION
"Identifies the serial number for the device. If the
SERIAL-NUMBER object is set by the user, then setting the
object does not need to be protected. If the SERIAL-NUMBER
object is set at the factory, then the SERVICE-PASSWORD object
must be set correctly before the SERIAL-NUMBER object is
writable. If this is a writable object, the POS should indicate
the maximum supported string length. If possible, encode the
serial number in a symbol set (like Roman-8) that matches the
ASCII character set and limit the characters used to ASCII
characters.
Additional information:
This value IS AFFECTED BY NVRAM resets, it is set to the
default value of XXXXXXXXXX, when a NVRAM init is done."
::= { id 3 }
fw-rom-datecode OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS optional
DESCRIPTION
"Identifies the base system firmware date code. The date code
will be encoded in the yyyymmdd format. There may be several
versions of the base system firmware. The date code associated
with the version of the base system firmware that is being used
is reported. There may be other date code objects for other
specific modules such as fonts, localization modules, etc.;
these other datecode objects are device specific."
::= { id 5 }
fw-rom-revision OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS optional
DESCRIPTION
"This identifies the system code firmware ROM revision code. The
format for a revision is major_revision.minor_revision. There
may be other ROM revision code objects for other specific ROMs
such as font ROMs, localization ROMs, etc; these other ROM
revision code objects are device specific."
::= { id 6 }
device-name OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..32))
ACCESS read-write
STATUS optional
DESCRIPTION
"User defined device name. The POS should indicate the maximum
supported string length. If the user entered string is too
long, the device will store as much as possible and will return
the <OKNearestLegal ValueSubstituted>.Additional information:
The maximum supported string length is 32
characters. If the user entered string is too long,
the device will store the first 32 characters and will
return the <noError> status."
::= { id 10 }
device-location OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-write
STATUS optional
DESCRIPTION
"User defined device location. The POS should indicate the
maximum supported string length. If the user entered string is
too long, the device will store as much as possible and will
return the <OKNearestLegal ValueSubstituted>.Additional information:
The maximum supported string length is 16
characters. If the user entered string is too long,
the device will store the first 16 characters and will
return the <noError> status."
::= { id 11 }
asset-number OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-write
STATUS optional
DESCRIPTION
"User defined asset number. The POS should indicate the maximum
supported string length. If the user entered string is too
long, the device will store as much as possible and will return
the <OKNearestLegal ValueSubstituted>.Additional information:
The maximum supported string length is 8
characters. If the user entered string is too long,
the device will store the first 8 characters and will
return the <noError> status."
::= { id 12 }
default-copies OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS optional
DESCRIPTION
"Returns or changes default copies. Default copies is the
default values used by the PDL to control the number of copies
of each page in the print job that are printed. The print job
can override this value. The list of supported values should be
documented in the device POS.
Additional information:
The supported values are 1 through 32000.
Setting to an unsupported value causes the printer to substitute in a snap
value and to return <noError> status.
The snaps are as follows:
<1 snaps to 1
>999 snaps to 32000"
::= { settings-pdl 4 }
default-lines-per-page OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS optional
DESCRIPTION
"Returns or changes the default number of lines per page. The
POS indicates the supported values. An unsupported value causes
the printer to use the closest supported value, causing the
printer to return the <noError>.
Additional information:
The supported values in LaserJet 8150 are 5 to 128.
Setting to an unsupported value causes the
the printer to substitute in a snap value and to return
<noError>
status.
The snap values are as follow:
<5 snaps to 5
>128 snaps to 128"
::= { settings-pdl 11 }
default-vmi OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS optional
DESCRIPTION
"Returns or changes the default vertical motion index. The unit
of measure for VMI is centipoints per line. The POS indicates
the supported values. An unsupported value causes the printer
to use the closest supported value, causing the printer to
return <noError>."
::= { settings-pdl 12 }
default-media-size OBJECT-TYPE
SYNTAX INTEGER {
eUSExecutive(1),
eUSLetter(2),
eUSLegal(3),
eFoolscap(10),
eROC16K(17),
eJISExecutive(18),
eISOandJISA5(25),
eISOandJISA4(26),
eJISB5(45),
eISOB5(65),
eJapanesePostcardDouble(72),
eMonarch(80),
eCommercial10(81),
eInternationalDL(90),
eInternationalC5(91),
eInternationalB5(100),
eCustom(101),
eUnknownMediaSize(32767)
}
ACCESS read-write
STATUS optional
DESCRIPTION
"This indicates the default media size. A write of an
unsupported value causes an <ErrorInvalidOrUnsupported Value>. Complete list of supported media sizes along with their
dimensions are listed in the ''Media Size Table'' near the end
of this document. (for a full list of media size enums see the
end of this file) "
::= { settings-pdl 13 }
cold-reset-media-size OBJECT-TYPE
SYNTAX INTEGER {
eUSLetter(2),
eISOandJISA4(26)
}
ACCESS read-write
STATUS optional
DESCRIPTION
"Returns or sets the media size that is used as the
DEFAULT-MEDIA-SIZE when a cold reset occurs."
::= { settings-pdl 19 }
reprint OBJECT-TYPE
SYNTAX INTEGER {
eOff(1),
eOn(2),
eAuto(3)
}
ACCESS read-write
STATUS optional
DESCRIPTION
"Returns or changes the reprint (jam recovery) setting. If eOn,
then the device will reprint pages jammed pages. If eOff, the
device will not attempt to reprint jammed pages. If eAuto, a
device dependent algorithm (which should be documented in the
POS) will be used to determine if the page gets reprinted. This
object controls all PDLs, unless a specific PDL supports its
own reprint control mechanism. To date, only PostScript has a
PDL reprint control mechanism."
::= { settings-pdl 36 }
pcl-total-page-count OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION
"Total number of PCL pages printed by the device.
Additional information:
In LaserJet 8150 the PCL page count is kept in
NVRAM, and the NVRAM value is updated at least every
10 pages. NOTE: The value returned by this object will
be incremented every page but if power is lost between
NVRAM updates, up to 9 pages of the page count may be
lost. The page count counter will be reset to zero
after 16,777,215 (2^24-1) pages.
The page count is incremented when a sheet of media is pulled from an input
tray. A duplex printed sheet will cause this counter to be incremented by
two."
::= { pdl-pcl 5 }
pcl-default-font-height OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS optional
DESCRIPTION
"Returns or changes the default PCL height. Height is an
approximate measure of the body of the type in centipoints. A
centipoint is 1/7200 inch. Height applies only to proportional
fonts. Point size, in points, can be converted to font height,
in centipoints, by multiplying the point size by 100. The POS
indicates the supported values. An unsupported value causes the
printer to use the closest supported value, causing the printer
to return <noError>. ''Closest'' means
the smallest absolute difference.
Additional information:
Supported values range from 400 to 99975, in
increments of 25 units.
Setting to an unsupported value causes the
printer to substitute in a snap value and to
return <noError> status.
The snap values are as follow:
<=400 snaps to 400
>=99975 snaps to 99975
Unsupported values in the range 400 to 99975 snap
DOWN to the previous supported value
(i.e 25293 snaps to 25275 or 75038 snaps to 75025)."
::= { pdl-pcl 13 }
pcl-default-font-source OBJECT-TYPE
SYNTAX INTEGER {
eInternal(1),
ePermanentSoft(2),
eRomSimm2(11),
eRomSimm3(12),
eRomSimm4(13)
}
ACCESS read-write
STATUS optional
DESCRIPTION
"Returns or changes the value of the default font source
variable in NVRAM."
::= { pdl-pcl 14 }
pcl-default-font-number OBJECT-TYPE
SYNTAX INTEGER(0..255)
ACCESS read-write
STATUS optional
DESCRIPTION
"Returns or changes the value of the default font number
variable in NVRAM. Writing an unsupported value causes the
printer to generate an <badValue>.
Additional information:
Valid numbers or 0 - 255, but only font numbers that are
included in the PCL FONT LIST are selectable."
::= { pdl-pcl 15 }
pcl-default-font-width OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS optional
DESCRIPTION
"Returns or changes the default PCL font width. Width is
expressed as the width of a character in centipoints. A
centipoint is 1/7200 inch. Width applies only to fixed space
fonts. Pitch, in character per inch, can be converted to font
width, in centipoints, by dividing 7200 by the pitch. The POS
indicates the supported values. An unsupported value causes the
printer to use the closest supported value, causing the printer
to return <noError>. ''Closest'' means
the smallest absolute difference.
Additional information:
Setting to an unsupported value causes the
printer to substitue in a snap value (listed below)
and return <noError> status.
The snap values for pitch are as follow:
<=44 snaps to 44
>=9999 snaps to 9999"
::= { pdl-pcl 16 }
postscript-total-page-count OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION
"Total number of PostScript pages printed by the device.
Additional information:
This object is only supported if the PostScript
option is installed.
In LaserJet 8150 the count is kept in NVRAM, and the
NVRAM value is updated at least every 10
sheets. NOTE: The value returned by this object will
be incremented every sheet but if power is lost between
NVRAM updates up to 9 sheets of the count may be
lost. The counter will be reset to zero
after 16,777,215 (2^24-1) pages. "
::= { pdl-postscript 5 }
postscript-print-errors OBJECT-TYPE
SYNTAX INTEGER {
eOff(1),
eOn(2)
}
ACCESS read-write
STATUS optional
DESCRIPTION
"Returns or changes the value of the print PostScript errors
setting. If eOn, PostScript prints an error page showing the
error encountered and the stack at the time of the error.
Additional information:
This object is only supported if the PostScript
option is installed."
::= { pdl-postscript 11 }
collated-originals-support OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-only
STATUS optional
DESCRIPTION
"Indicates that the printer can create multiple, collated
'originals' of a job and shows the level of support for this
capability.
cCollatedOriginals - The printer can create multiple
collated originals, or 'mopies'. This is the base
functionality required by the other collection items.
cProofAndHold - The printer saves a copy of the job while
printing the first mopy. Later, this held job can be
released and the rest of the mopies will print.
cSecurityPrint - The printer spools the job and holds the
job until the user releases the job by entering a
<<hidden>> at the printer's control panel.
cAutoHighlight - The printer prints the job a number of
times with a mail distribution list prepended to each
job. A different mailing address is highlighted on each
mopy.
cCollatedAtSpeed - The printer can create multiple collated
copies where all copies after the original are printed
at engine speed.
Additional information:
Indicates that the printer can create multiple, collated
originals of a job and shows the level of support for this
capability.
cCollatedOriginals - The printer can create multiple collated
originals, or mopies.
This is the base functionality required by the other
collection items.
Without disk, this object will not exist. This will be set at
boot-up initialization. If the disk fails, in any way, then
the disk error functionality will handle the situation.
A color printer (LaserJet 4550) that only has a RAMDISK installed is
treated like there is no disk and therefore this object will
not exist.
The value of this object will be:
!cCollatedOriginals - Only FLASH installed
cCollatedOriginals - IDE is installed combined
with/without FLASH
cCollatedOriginals - RAMDISK is On combined with/without FLASH"
::= { status-system 42 }
host-application-available-memory OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION
"Returns the amount of memory, in bytes, that the device has
available for job-related processing or resources. Also known
as driver work space (DWS) memory."
::= { status-system 59 }
socket-ping-job-events-version OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..10))
ACCESS read-only
STATUS optional
DESCRIPTION
"This object reports the current version of the Socket Ping Job
Events capability. The version number is returned as a string
in the format MAJOR.MINOR.SUB version. (eg. 1.0.1) If socket
ping is not supported by this printer then the object is either
not implemented or it returns a '0'."
::= { socket-ping 1 }
job-info-change-id OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(16))
ACCESS read-only
STATUS optional
DESCRIPTION
"Returns the current value of an object in the job-info sub-tree
whose value has changed. Define the object identifier for the
object whose value has changed as
job-info.required-field.optional-field.job-id. job-info
represents the OID prefix of all objects in the job-info
sub-tree. Required-field represents the OID field value that
follows the job-info prefix. Since some objects in the job-info
sub-tree have two OID fields between the job-info prefix and
the job-id, the optional-field represents the OID field between
the required-field and the job-id field, if present. Using this
definition, the format for the JOB-INFO-CHANGE-ID binary value
can be described as follows:
Bytes 0-3 : required-field
Bytes 4-7 : optional-field, or all zeros if there
is no optional field
Bytes 8-11: Job ID.
Bytes 12-n : The value of the object job-info.
required-field.optional-field.job-id.
All multi-byte values stored in Motorola (big-endian) format,
where the most significant byte occurs first.
Additional information:
LaserJet 8100 will use this object to report
changes to the job-info-pages-printed and job-info-state
objects. The required-field (bytes 0 through 3) will
designate whether the change to be reported involves the
pages printed (13) or job state (15). The optional-field
(bytes 4 through 7) will always be zeroes. The value-field
(bytes 12 through 15) will contain the new value for pages
printed or job state cast to a 32-bit integer.
Note: It is possible that traps generated by this object
have the same value. This is caused by the architecture of
LaserJet 8100. In the LaserJet 8100 System, it is highly probable that
the object value will change so rapidly that when the trap is
processed, PML will read the same value twice. This is timing
related and will generally be seen at the end of a job."
::= { settings-job 3 }
hold-job-timeout OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS optional
DESCRIPTION
"The time, in minutes, that the printer will wait before
automatically deleting a held job. This allows the printer to
automatically clean up jobs that have been forgotten (held but
never released).
Additional information:
This only applies to temporary held jobs, i.e., HOLD=ON or
PROOF. This is a global timer that only affects the jobs
that are sent after it is set.
A value of 0 means never delete the jobs.
Setting it to an unsupported value causes
the printer to substitute a value (listed
below) and to return <noError>
status.
LaserJet 4600 supports values of 0, 60, 240, 1440, and 10080
The values are as follows:
<=0 snap to 0 (disabled)
>=1 and <=150 snap to 60 (60 minutes)
>=151 and <=840 snap to 240 (4 hours)
>=841 and <=2880 snap to 1440 (1 day)
>=2881 snap to 10080 (1 week)"
::= { settings-job 10 }
current-job-parsing-id OBJECT-TYPE
SYNTAX INTEGER(-1..2147483647)
ACCESS read-only
STATUS optional
DESCRIPTION
"Contains the printer assigned job identification for the job
currently being processed by the processing PDL sub-system. The
job ID is a monotonically increasing number. The job ID may be
reset to zero at power-up and may roll over to zero after
reaching some maximum value.
Additional information:
A value of -1 is returned when the printer
is not parsing a job.
When data for a new job is detected, this object is
updated (the job may or may not turn out to be a Null
Job); however, the trap does not occur until the printer
determines that it is not a Null Job. (A job is considered
to be a 'null job' if it has no name or job attribute,
causes no pages to be printed, and consumes MIN_JOB_SIZE
(9) or fewer bytes.) A trapped value will differ from
the previous value by one or more.
Some job-info- objects are created when the first data
bytes are received. If the printer determines that the
job is a Null Job, the job-info- objects related to the
Null Job are deleted. LaserJet 8100 retains the job-info-
objects for the MAX_JOBS_IN_LIST (32) most recent jobs
that are not Null Jobs.
The first job received after power-up will have job ID 1,
and the job ID will increment to 2,147,483,647 before
rolling to zero. To distinguish whether a power cycle or a
rollover causes a reduction in the job ID value, the
object prtGeneralConfigChanges can be watched and if it
increments at the same time as the drop is observed in
the value of CURRENT-JOB-PARSING-ID, then a power cycle
is the most likely cause."
::= { job-being-parsed 1 }
job-info-name1 OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS optional
DESCRIPTION
"Contains the first part of this print job's name. The last OID
field for this dynamic object contains the job ID.
Additional information:
The job name is the string specified by the
NAME= parameter of the @PJL JOB command which allows a
maximum of 80 characters. The first 40 characters are
in this object and the second 40 are in job-info-name2.
The symbol set is Roman-8.
When jobs are nested, the value assigned to this object
is the name provided by the most recent @PJL JOB NAME=
command. If no name is provided, a null string is
returned."
::= { job-info 1 }
job-info-name2 OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS optional
DESCRIPTION
"Contains the second part of this print job's name. The last OID
field for this dynamic object contains the job ID.
Additional information:
See job-info-name1."
::= { job-info 2 }
job-info-stage OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-only
STATUS optional
DESCRIPTION
"Indicates what printer sub-systems are currently processing
this print job. The last OID field for this dynamic object
contains the job ID. cSourceSubsystem - some of the job is in
the printer I/O subsystem. cProcessingSubsystem - some of the
job is in the printer imaging processing subsystem.
cDestinationSubsystem - some of the job is being printed.
Additional information:
For LaserJet 8100, cSourceSubsystem and
cProcessingSubsystem will always be set and cleared
together. They are set when the beginning of the
job is detected, and they are cleared when the end
of the job is parsed.
A non-printing job will never set
cDestinationSubsystem.
When a page is ready to be printed (the intermediate has
been built and the page is `closed' by the personality),
cDestinationSubsystem will be set even if a page of a
previous job is currently being printed.
cDestinationSubsystem remains set until the last page of
the job has finished printing.
If a page requires extensive processing and allows all
the previous pages of a job to complete printing,
cDestinationSubsystem will remain set until the last
page of the job has finished printing."
::= { job-info 10 }
job-info-io-source OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION
"Indicates which I/O source, the print job was received over.
The value maps to port numbering scheme supported in the
DEVICE/SOURCE-SUBSYSTEM/IO/PORTS sub-tree."
::= { job-info 11 }
job-info-pages-processed OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION
"Indicates the number of pages processed by the processing
subsystem. If neither the cSourceSubsystem or the
cProcessingSubsystem items are in the associated JOB-INFO-STAGE
object, then this object contains the total number of pages
processed for this job. The last OID field for this dynamic
object contains the job ID.
Additional information:
This object is incremented by one when a
page is processed (`closed' by the personality), regardless
of the number of pages that are printed as a result of the
single page processed. In other words, it does not matter
how many identical copies of a page are printed or no pages
may be printed if operating in silent run mode, this count
is incremented exactly once.
A page is considered processed when all of the input
data has been processed for a page (that is, when the
intermediate has been produced, and the personality has
`closed' the page. At this time, the image of the page is
not necessarily completely formed.)"
::= { job-info 12 }
job-info-pages-printed OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION
"Indicates the number of pages printed by the destination
subsystem. If none of the cSourceSubsystem,
cProcessingSubsystem or cDestinationSubsystem items are in the
associated JOB-INFO-STAGE object, then this object contains the
total number of pages printed for this job. This value may
increase by two each time for duplex jobs. The last OID field
for this dynamic object contains the job ID.
Additional information:
If multiple copies of a page are printed,
each copy is counted individually."
::= { job-info 13 }
job-info-size OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION
"Indicates the number of bytes of data processed by the
processing subsystem. If neither of the cSourceSubsystem or
cProcessingSubsystem items are in the associated JOB-INFO-STAGE
object, then this object contains the size of this job, in
bytes. The last OID field for this dynamic object contains the
job ID.
Additional information:
This count may be incremented by values
other than one as blocks of data are processed; blocks
of data (which may be as large as 2K bytes) will be
processed in a varying amount of time.
During the processing of a job and even when a job completes,
an exact count of the number of I/O bytes processed by the
job is not necessarily to be expected."
::= { job-info 14 }
job-info-state OBJECT-TYPE
SYNTAX INTEGER {
eAborted(3),
eWaitingForResources(4),
ePrinted(5),
eTerminating(7),
eCancelled(10),
eProcessing(11),
eScanning(12),
eSending(13)
}
ACCESS read-only
STATUS optional
DESCRIPTION
"Indicates the state of the job. The last OID field for this
dynamic object contains the job ID.
eAborted - the print job was aborted.
eWaitingForResources - the print job requires resources
that are not currently available. Example resources
that can cause the job to wait include the print engine
or PDL processor being unavailable. The print engine
could be unavailable due to paper out, paper jam,
staple out, stapler jam, marking agent low, output bin
full, etc. The PDL processor could be unavailable due
to an off-line condition. Each printer specific object
specification should state which conditions cause a job
to be waiting for resources and also state which
objects can be retrieved by an application to determine
the exact cause of a resource being unavailable.
ePrinted - the job has printed. The related JOB-INFO-
OUTCOME object indicates if any problems were
encountered while the job was processed.
eRetained - the job can be reprinted.
eTerminating - the job was aborted or cancelled and is
currently is terminating.
eInterrupted - the job has been interrupted. The job can be
continued.
ePaused - the job has been paused. The job can be
continuted.
eCancelled - the job has been cancelled.
eProcessing - the job is currently being printed normally.
"
::= { job-info 15 }
job-info-outcome OBJECT-TYPE
SYNTAX INTEGER {
eOk(3)
}
ACCESS read-only
STATUS optional
DESCRIPTION
"Indicates if any warning or error conditions were encountered
while processing the assoicated job. The last OID field for
this dynamic object contains the job ID.
Additional information:
In LaserJet 8100, warnings and errors are not recorded
in this object. Although no meaningful information can be
obtained from this object, it is kept around for the
compatibility needs of existing software."
::= { job-info 19 }
job-info-outbins-used OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-only
STATUS optional
DESCRIPTION
"Indicates which output bins this job has delivered printed
pages to. The last OID field for this dynamic object contains
the job ID.
Additional information:
The bins designated by this collection include
the printer's own output bins as well as the `logical output
bins' associated with any attached external paper handling
devices. (The mapping of the physical output bins of an
external paper handling device to its `logical output bins'
depends on the usage mode of the device. For instance, in
`mailbox mode', there is one-to-one correspondence of
`logical output bins' to physical bins, whereas in `stacker
mode', one `logical output bin' may map to several physical
bins.)
Although LaserJet 4100 and LaserJet 4550 both come with two output
bins -- a face-down bin on the top of the device and a
face-up bin at the back of the device -- firmware will not
provide a means of selecting between the two, nor will it
report which of the two gets used. For this reason, bit 0
(cOutbin1) of this collection is being used to designate
both of these bins together."
::= { job-info 20 }
job-info-physical-outbins-used OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-only
STATUS optional
DESCRIPTION
"Indicates which physical output bins this job has delivered
printed pages to. The last OID field for this dynamic object
contains the job ID.
Additional information:
The output bins designated by the bits of
this collection include the standard output bin(s) plus the
physical bins of attached external paper handling devices.
The configuration (if any) of external paper handling devices
will determine the mapping of individual bits in this
collection to the physical bins of the devices.
For LaserJet 4100 and LaserJet 4550, the cOutbin1 is used for Face Down
bin, cOutbin2 is used for Face Up bin, and 3-15 are used for
the 13 optional output bins (12 plus an extension to the Face
Up bin) for backwards compatibility with LaserJet 8000/LaserJet 8100 and
forwards compatibility with LaserJet 8150. However, since they
cannot distinguish output going to the Face Up or Face Down
bin in the firmware because the diverter can only be moved
manually, bit 0 (cOutbin1) is being used to designate
both of these bits together. If an external paper handling
output device is connected, then bit 2 (cOutbin3) will
represent the device's first output bin (and so on)."
::= { job-info 22 }
job-info-attr-1 OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(1..80))
ACCESS read-only
STATUS optional
DESCRIPTION
"Returns the value that was set in PJL via the SET JOBATTR=
command. Attribute objects are saved sequentially, starting
with 1, after the start of a job. If more attributes are set
than there are objects to store them, the excess JOBATTR values
are ignored. If the corresponding SET JOBATTR= command has not
been received when a get is done for this object, a status of
<noSuchName> will be returned."
::= { job-info-attribute 1 }
job-info-attr-2 OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(1..80))
ACCESS read-only
STATUS optional
DESCRIPTION
"Returns the value that was set in PJL via the SET JOBATTR=
command. See JOB-INFO-ATTR-1 for details."
::= { job-info-attribute 2 }
job-info-attr-3 OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(1..80))
ACCESS read-only
STATUS optional
DESCRIPTION
"Returns the value that was set in PJL via the SET JOBATTR=
command. See JOB-INFO-ATTR-1 for details."
::= { job-info-attribute 3 }
job-info-attr-4 OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(1..80))
ACCESS read-only
STATUS optional
DESCRIPTION
"Returns the value that was set in PJL via the SET JOBATTR=
command. See JOB-INFO-ATTR-1 for details."
::= { job-info-attribute 4 }
job-info-attr-5 OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(1..80))
ACCESS read-only
STATUS optional
DESCRIPTION
"Returns the value that was set in PJL via the SET JOBATTR=
command. See JOB-INFO-ATTR-1 for details."
::= { job-info-attribute 5 }
job-info-attr-6 OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(1..80))
ACCESS read-only
STATUS optional
DESCRIPTION
"Returns the value that was set in PJL via the SET JOBATTR=
command. See JOB-INFO-ATTR-1 for details."
::= { job-info-attribute 6 }
job-info-attr-7 OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(1..80))
ACCESS read-only
STATUS optional
DESCRIPTION
"Returns the value that was set in PJL via the SET JOBATTR=
command. See JOB-INFO-ATTR-1 for details."
::= { job-info-attribute 7 }
job-info-attr-8 OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(1..80))
ACCESS read-only
STATUS optional
DESCRIPTION
"Returns the value that was set in PJL via the SET JOBATTR=
command. See JOB-INFO-ATTR-1 for details."
::= { job-info-attribute 8 }
job-info-attr-9 OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(1..80))
ACCESS read-only
STATUS optional
DESCRIPTION
"Returns the value that was set in PJL via the SET JOBATTR=
command. See JOB-INFO-ATTR-1 for details."
::= { job-info-attribute 9 }
job-info-attr-10 OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(1..80))
ACCESS read-only
STATUS optional
DESCRIPTION
"Returns the value that was set in PJL via the SET JOBATTR=
command. See JOB-INFO-ATTR-1 for details."
::= { job-info-attribute 10 }
job-info-attr-11 OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(1..80))
ACCESS read-only
STATUS optional
DESCRIPTION
"Returns the value that was set in PJL via the SET JOBATTR=
command. See JOB-INFO-ATTR-1 for details."
::= { job-info-attribute 11 }
job-info-attr-12 OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(1..80))
ACCESS read-only
STATUS optional
DESCRIPTION
"Returns the value that was set in PJL via the SET JOBATTR=
command. See JOB-INFO-ATTR-1 for details."
::= { job-info-attribute 12 }
job-info-attr-13 OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(1..80))
ACCESS read-only
STATUS optional
DESCRIPTION
"Returns the value that was set in PJL via the SET JOBATTR=
command. See JOB-INFO-ATTR-1 for details."
::= { job-info-attribute 13 }
job-info-attr-14 OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(1..80))
ACCESS read-only
STATUS optional
DESCRIPTION
"Returns the value that was set in PJL via the SET JOBATTR=
command. See JOB-INFO-ATTR-1 for details."
::= { job-info-attribute 14 }
job-info-attr-15 OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(1..80))
ACCESS read-only
STATUS optional
DESCRIPTION
"Returns the value that was set in PJL via the SET JOBATTR=
command. See JOB-INFO-ATTR-1 for details."
::= { job-info-attribute 15 }
job-info-attr-16 OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(1..80))
ACCESS read-only
STATUS optional
DESCRIPTION
"Returns the value that was set in PJL via the SET JOBATTR=
command. See JOB-INFO-ATTR-1 for details."
::= { job-info-attribute 16 }
job-info-requested-originals OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION
"The number of requested collated copies. The value was supplied
with the job via PJL QTY variable, the PostScript Collate and
NumCopies entries in the page device dictionary, or via some
other mechansim."
::= { job-info 24 }
job-info-page-count-current-original OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION
"The page number being printed within the current copy of a
collated multi-copy job. This value changes when the
job-info-pages-printed changes. The job-info-pages-printed
indicates the total number of pages printed in the job, while
this object indicates the number of pages printed for this copy
of a collated multi-copy job.
Additional information:
The number of pages in the current copy of a collated
multi-copy job which have been completely printed and
safely delivered to the output bin."
::= { job-info 25 }
job-info-pages-in-original OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION
"Number of pages in a single copy of a collated multi-copy job."
::= { job-info 26 }
job-info-printed-originals OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION
"Number of collated copies completely printed and delivered to
the output bin at time of query."
::= { job-info 27 }
job-info-accounting-media-size OBJECT-TYPE
SYNTAX INTEGER {
eUSExecutive(1),
eUSLetter(2),
eUSLegal(3),
eLedger(11),
eROC16K(17),
eJISExecutive(18),
eROC8K(19),
eISOandJISA5(25),
eISOandJISA4(26),
eISOandJISA3(27),
eJISB5(45),
eJISB4(46),
eISOB5(65),
eJapansePostcardDouble(72),
eMonarch(80),
eCommercial10(81),
eInternationalDL(90),
eInternationalC5(91),
eInternationalB5(100),
eCustom(101),
eUSLetterR(258),
eISOandJISA4R(282),
eUnknownMediaSize(32767)
}
ACCESS read-only
STATUS optional
DESCRIPTION
"Contains the media size of the printed job. The media size of
the first page will decide the media size of the entire job.
The return value of this object will only be valid when the
printer finishes printing the entire job."
::= { job-info-accounting 1 }
job-info-accounting-media-type OBJECT-TYPE
SYNTAX INTEGER {
eUnknownMedia(1),
eStandardType(2),
ePreprinted(3),
eBond(4),
eLetterhead(5),
eTransparency(7),
eLabels(8),
eRecycled(9),
eColored(10),
eCardStock(11),
eRough(12),
ePrepunched(13),
eHeavy(14),
eUserType1(16),
eUserType2(17),
eUserType3(18),
eUserType4(19),
eUserType5(20)
}
ACCESS read-only
STATUS optional
DESCRIPTION
"Contains the media type of the printed job. The media type of
the first page will decide the media type of the entire job.
The return value of this object will only be valid when the
printer finishes printing the entire job."
::= { job-info-accounting 2 }
job-info-accounting-finishing-options OBJECT-TYPE
SYNTAX INTEGER {
eNoFinish(1),
eOffset(2),
ePunch(3),
eStapler(4),
eFinisher(5)
}
ACCESS read-only
STATUS optional
DESCRIPTION
"Contains the finishing option used on the printed job. The
finishing option specified for the first page will decide the
finishing option of the entire job. The return value of this
object will only be valid when the printer finishes printing
the entire job."
::= { job-info-accounting 3 }
job-info-accounting-media-simplex-count OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION
"Contains the total number of simplex pages printed in a
particular job."
::= { job-info-accounting 4 }
job-info-accounting-media-duplex-count OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION
"Contains the total number of duplex pages printed in a
particular job."
::= { job-info-accounting 5 }
job-info-accounting-grayscale-impression-count OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION
"Contains the total number of monochrome pages printed in a
particular job."
::= { job-info-accounting 6 }
job-info-accounting-color-impression-count OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION
"Contains the total number of color pages printed in a
particular job."
::= { job-info-accounting 7 }
job-info-accounting-black-dots OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION
"Contains the total number of black pixels used in a particular
job."
::= { job-info-accounting 8 }
job-info-accounting-yellow-dots OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION
"Contains the total number of yellow pixels used in a particular
job."
::= { job-info-accounting 9 }
job-info-accounting-cyan-dots OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION
"Contains the total number of cyan pixels used in a particular
job."
::= { job-info-accounting 10 }
job-info-accounting-magenta-dots OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION
"Contains the total number of magenta pixels used in a
particular job."
::= { job-info-accounting 11 }
job-info-accounting-job-type OBJECT-TYPE
SYNTAX INTEGER {
ePrintJob(1),
eIPPJob(2),
eCopyJob(3),
eCopyInterruptJob(4),
eJetSendJob(5),
eInternalPage(6),
eCleaningPage(7),
eAutoCleaningPage(8),
eDigitalSendJob(9),
eWebPrintJob(10),
eFaxPrintJob(11),
eRetrievedJob(12),
ePhotoCardPrintJob(13),
eUnknownJob(1000)
}
ACCESS read-only
STATUS optional
DESCRIPTION
"Keeps track of what type of job is processed. "
::= { job-info-accounting 14 }
held-job-user-name OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..40))
ACCESS read-only
STATUS optional
DESCRIPTION
"User name that is obtained by the driver through some internal
method or from user input.
Additional information:
The following is a general description for all the JOB-MANAGEMENT
objects described below. These object describe the attributes of the
dynamic list containing all the stored jobs on the disk available for
printing or deleting via the job-management feature. The jobs on this
list are not deleted from the disk unless explicitly specified by the
user. A print job may be specified for retention by PJL commands in the
data stream.
Following is a list of the PJL commands (i.e. these comments describe
the PJL implementation and in some cases do not reflect the PML
implementation.):
@PJL SET HOLD=OFF|ON|PROOF|STORE|PRINT
GENERAL DESCRIPTION:
This variable specifies the retention classification of the job. The
values indicate whether the job is printed immediately and/or stored.
OFF: The job is printed but not retained on disk after printing. This
is the default value.
ON: This setting may be thought of as free proof-and-hold. The
requested number of copies will be printed and the job will be
temporarily stored on disk. The job will then be available for printing
additional copies through the control panel and through PML. There will
be a limit to the number of these temporary jobs that may be stored, and
when the limit is exceeded the oldest job will be removed from the disk.
PROOF: One copy of the job is printed and remaining copies are stored
on disk. The job is then available to select for printing via the
control panel menus or PML. The job will be deleted from the disk when
the disk space is needed for another proof and hold job but only after
the additional copies have been printed. It will also be deleted when
the user sends down another proof and hold job with the same job name,
or the user explicitly deletes the job.
STORE: The job is not printed immediately but is retained on disk. The
job is available to select for printing via the control panel
DEFAULT VALUE: OFF
The value will be stored in RAM only, not in NVRAM.
The legal PJL commands are SET and INQUIRE. DEFAULT is not allowed.
The variable will appear in the PJL INFO VARIABLES list.
@PJL SET USERNAME=<80 bytes>
GENERAL DESCRIPTION:
Eighty-character user name that is obtained by the driver through some
internal method or from user input. If the job stream does not contain
a USERNAME the default value will be NO USER NAME. The driver is
responsible for determining the size of the printers control panel and
sending a string of appropriate length.
DEFAULT VALUE: NO USER NAME
The value will be stored in RAM only, not in NVRAM.
The legal PJL commands are SET and, INQUIRE. DEFAULT is not allowed.
The variable will appear in the PJL INFO VARIABLES list.
@PJL SET JOBNAME=<80 bytes>
GENERAL DESCRIPTION:
Eighty-character job name that may be generated by the driver or
obtained from user input. This value may be used in conjunction with
the USERNAME to select a job from the front panel. If the job stream
does not contain a JOBNAME, the printer will assume no job name; each
subsequent job that is sent down by the same user would replace the
users last job on disk. The driver is responsible for determining the
size of the printers control panel and sending a string of appropriate
length.
NOTE: The limit of 80 bytes is a PJL limit. The limit for PML will
be 40 bytes.
DEFAULT VALUE: NULL STRING
The value will be stored in RAM only, not in NVRAM.
The legal PJL commands are SET and INQUIRE. DEFAULT is not allowed.
The variable will appear in the PJL INFO VARIABLES list.
@PJL SET HOLDTYPE=PUBLIC|PRIVATE
GENERAL DESCRIPTION:
This variable specifies the privacy level of the job.
PUBLIC: The job does not require a PIN in order to be released for
printing. This is the default value.
PRIVATE: The job requires a PIN in order to be released for printing.
The PIN is specified by the HOLDKEY variable. If the
HOLDTYPE is set to PRIVATE, a HOLDKEY value must be specified. If no
HOLDKEY is specified, the job will be considered PUBLIC.
DEFAULT VALUE: PUBLIC
The value will be stored in RAM only, not in NVRAM.
The legal PJL commands are SET and INQUIRE. DEFAULT is not allowed.
The variable will appear in the PJL INFO VARIABLES list.
@PJL SET HOLDKEY=4 digits, 0000...9999
GENERAL DESCRIPTION:
A 4-digit string, each digit 0-9, that is specified in the job stream
and then required to be entered in order to release the job for
printing. If a HOLDTYPE is PRIVATE, a HOLDKEY value must be specified.
If no HOLDKEY value is specified, a job will be considered PUBLIC.
DEFAULT VALUE: NULL STRING
The value will be stored in RAM only, not in NVRAM.
The legal PJL commands are SET and INQUIRE. DEFAULT is not allowed.
The variable will appear in the PJL INFO VARIABLES list.
The format for the OID is as follows:
3.4.1.6.x.y
<-----> | |
| | \
/ | job-id in the system
/ \
PML_JOB_MGNT_ROOT_OID \
job attribute 1..6
x values are 1..6:
1) user-name: user name that is obtained by the driver through some
internal method or from user input.
2) job-name: job name may be generated by the driver or obtained from
user input.
3) hold: indicates the retention classification of the job. The values
indicate whether the job is printed immediately and/or stored. There
are 4 options:
OFF: The job is printed but not retained on the disk.
ON: The job is printed and stored temporarily on the disk.
STORE: The job is not printed but stored on the disk.
PROOF: One copy of the job is printed and the remaining copies are
stored on the disk.
4) holdtype: The variable specifies the security level of the job.
PUBLIC: The job does not require a PIN in order to release the job for
printing.
PRIVATE: The job requires a PIN in order to be released for printing.
5) quantity: number of copies to print. Valid values are 0..999.
6) pin: A 4 digit string, each digit is 0-9, that is specified in the
job stream and then required to be entered in order to release the job
for printing.
y : an unsigned 32-bit number which uniquely identifies the job. The job
id for the job remains the same for the job until it is deleted from the
held jobs list.
For example, the OID below is asking for the user name of the
job whose id is 3. The application would issue:
OID
get 3.4.1.6.1.3
For example, the <getnext> OID values sequence is as follows:
OID returned OID
getnext 3.4.1.6 3.4.1.6.1.1
getnext 3.4.1.6.1.1 3.4.1.6.1.2
getnext 3.4.1.6.2.1 3.4.1.6.2.2
***
getnext 3.4.1.6.1.6 3.4.1.6.1.7
getnext 3.4.1.6.2.1 3.4.1.6.2.2
getnext 3.4.1.6.5.2828 3.4.1.6.6.1
NOTE: for example above, job id 2828 is the last job in the list of
held jobs.
***
Also supported is <getnext> on the job attributes:
OID returned OID
getnext 3.4.1.6.1 3.4.1.6.1.1
getnext 3.4.1.6.6 3.4.1.6.6.1"
::= { held-job-info 1 }
held-job-job-name OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..40))
ACCESS read-only
STATUS optional
DESCRIPTION
"The job name may be generated by the driver or obtained from
user input."
::= { held-job-info 2 }
held-job-retention OBJECT-TYPE
SYNTAX INTEGER {
eHoldOff(1),
eHoldOn(2),
eHoldStore(3),
eHoldProof(4)
}
ACCESS read-only
STATUS optional
DESCRIPTION
"Indicates the retention classification of the job. The values
indicate whether the job is printed immediately or stored.
There are 4 options:
eHoldOff: The job is printed but not retained on the disk.
eHoldOn: The job is printed and stored temporarily on the
disk.
eHoldStore: The job is not printed but stored on the disk.
eHoldProof: One copy of the job is printed and the
remaining copies are stored on the disk. "
::= { held-job-info 3 }
held-job-security OBJECT-TYPE
SYNTAX INTEGER {
eHoldTypePublic(1),
eHoldTypePrivate(2)
}
ACCESS read-only
STATUS optional
DESCRIPTION
"The variable specifies the security level of the job.
eHoldTypePublic: The job does not require a PIN in order to
release the job for printing.
eHoldTypePrivate: The job requires a PIN in order to be
released for printing. "
::= { held-job-info 4 }
held-job-quantity OBJECT-TYPE
SYNTAX INTEGER(1..999)
ACCESS read-only
STATUS optional
DESCRIPTION
"Number of copies to print."
::= { held-job-info 5 }
held-job-pin OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..4))
ACCESS read-only
STATUS optional
DESCRIPTION
"A string that is specified in the job stream and then required
to be entered in order to release the job for printing. PIN
stands for Personal Identification Number.
Additional information:
Must be a 4 digit string, each digit must be 0..9 or a null string
if there is no pin.
For security purposes, you can no longer get the value of the PIN."
::= { held-job-info 6 }
held-job-print OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(12))
ACCESS write-only
STATUS optional
DESCRIPTION
"Instructs the printer to schedule the specified held job for
printing with the specified number of copies. The job-id is
used to identify which job to print. A held job can also be
printed from the control panel.
Additional information:
Bytes 0-3 is the job id of the job to print.
Bytes 4-7 is the number of copies to print.
Bytes 8-11 (optional) contain the PIN for
a Private job. "
::= { held-job-control 1 }
held-job-delete OBJECT-TYPE
SYNTAX INTEGER
ACCESS write-only
STATUS optional
DESCRIPTION
"Instructs the printer to delete the specified held job from the
list. The job-id is used to identify which job to delete. A
held job can also be deleted from the control panel.
Additional information:
Setting this to a value that is not a Held Job on the
system or is a Private Held Job returns <ErrUnsupValue>.
To delete a private Held Job, you must use the PML object
HELD-JOB-PRINT with a quantity of 0 and supply the correct
HELD-JOB-PIN with the request. (See HELD-JOB-PRINT)"
::= { held-job-control 2 }
held-job-set-queue-size OBJECT-TYPE
SYNTAX INTEGER(0..100)
ACCESS read-write
STATUS optional
DESCRIPTION
"Sets the maximum number of jobs which can be stored in the held
job list.
Additional information:
Sets the size of the temporary job lists queue."
::= { held-job-control 3 }
held-job-enable OBJECT-TYPE
SYNTAX INTEGER {
eDisabled(1),
eEnabled(2)
}
ACCESS read-write
STATUS optional
DESCRIPTION
"Enables or disables Job Retention (Job Hold). The valid values
are eDisabled and eEnabled. (Specifying an invalid mode causes
an <badValue> error to be returned.) When
eDisabled is specified all Job Retention (Hold, Proof, Store,
PIN Printing) is disabled. When eEnabled is specified, the Job
Retention characteristics of a given job are defined by the PJL
variable SET HOLD.
Additional information:
When disabled, held jobs are not removed,
but must be explicitly removed through the Control Panel
or the PML object HELD-JOB-DELETE."
::= { held-job-control 4 }
mopy-mode OBJECT-TYPE
SYNTAX INTEGER {
eOff(1),
eStandard(4),
eEnhanced(5)
}
ACCESS read-write
STATUS optional
DESCRIPTION
"Controls or reports how mopies are generated. eOff turns off
the mopy feature. eAuto allows the device to determine the best
method for generating mopies based on the device configuration.
eStandard spools the I/O data and replays the I/O data multiple
times to generate the mopies. eEnhanced spools the rasterized
page images and replays the rasterized data to generate the
mopies. Typically, the rasterized data will be larger and will
allow all but the first mopy to print at speed. If the job
being mopied is not extremely complex, then the first mopy will
print at speed also."
::= { settings-spooler 1 }
default-vertical-black-resolution OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS optional
DESCRIPTION
"Returns or changes the value of the default vertical black
resolution. The units are dots per inch.
Additional information:
In LaserJet 8100 changing this OID also causes
DEFAULT-HORIZONTAL-BLACK RESOLUTION to change.
DEFAULT-HORIZONTAL-BLACK-RESOLUTION and
DEFAULT-VERTICAL-BLACK-RESOLUTION must always be the
same. The supported values are:
LaserJet 4100: 300, 600, 1200
Color Products: 600
LaserJet 9000: 300, 600
Setting to an unsupported value causes the printer
to substitute in a snap value and
to return <noError> status.
The snap values are as follow:
LaserJet 4100:
450 >= n < 900 snaps to 600
n >= 900 snaps to 1200
Color Products:
n snaps to 600
LaserJet 9000:
n < 450 snaps to 300
n >=450 snaps to 600 "
::= { settings-pdl 8 }
default-horizontal-black-resolution OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS optional
DESCRIPTION
"Returns or changes the value of the default horizontal black
resolution. The units are dots per inch.
Additional information:
In LaserJet 8100 changing this object also causes
DEFAULT-VERTICAL-BLACK RESOLUTION to change.
DEFAULT-HORIZONTAL-BLACK-RESOLUTION and
DEFAULT-VERTICAL-BLACK-RESOLUTION must always be the
same. The supported values are:
LaserJet 4100: 300, 600, 1200
Color Products: 600
LaserJet 9000: 300, 600
Setting to an unsupported value causes the printer
to substitute in a snap value and to
return <noError> status.
The snap values are as follow:
LaserJet 4100:
n < 450 snaps to 300
450 >= n < 900 snaps to 600
n >= 900 snaps to 1200
Color Products:
n snaps to 600
LaserJet 9000:
n < 450 snaps to 300
n >=450 snaps to 600 "
::= { settings-pdl 9 }
default-page-protect OBJECT-TYPE
SYNTAX INTEGER {
eOn(2)
}
ACCESS read-write
STATUS optional
DESCRIPTION
"Returns or changes the default page protection behavior. If
eOff, the device does not reserve memory for holding the entire
raster form of a processed page. If eOn, then memory is
reserved. If eAuto, the device determines the amount of memory
to reserve.
Additional information:
Setting to eOn causes MET to be more conservative, but
it will not allocate memory to hold an entire
rasterized page."
::= { settings-pdl 10 }
default-bits-per-pixel OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS optional
DESCRIPTION
"Controls the number of levels used (per pixel) when printing
grayscale or color images."
::= { settings-pdl 39 }
mio1-model-name OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS optional
DESCRIPTION
"Returns product information identifying the I/O card. Example:
XXXX."
::= { mio1 2 }
mio1-manufacturing-info OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS optional
DESCRIPTION
"Returns information describing the manufacture of the I/O card
installed in MIO/EIO slot 1. May include serial number and
firmware revision.
Additional information:
The format of the string returned is determined by
the manufacturer of the EIO device. There is no standard for
content of the string."
::= { mio1 3 }
mio1-type OBJECT-TYPE
SYNTAX INTEGER {
eEmpty(1),
eUnknown(2),
eDiskDrive(8),
eIOCard(12)
}
ACCESS read-only
STATUS optional
DESCRIPTION
"Returns an indication of the type of option installed in
MIO/EIO slot 1. See SIMM1-TYPE for an explanation of the
enumerations."
::= { mio1 4 }
mio2-model-name OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS optional
DESCRIPTION
"Returns product information identifying the I/O card. Example:
XXXX."
::= { mio2 2 }
mio2-manufacturing-info OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS optional
DESCRIPTION
"Returns information describing the manufacture of the I/O card
installed in MIO/EIO slot 2. May include serial number and
firmware revision.
Additional information:
The format of the string returned is determined by
the manufacturer of the EIO device. There is no standard for
content of the string."
::= { mio2 3 }
mio2-type OBJECT-TYPE
SYNTAX INTEGER {
eEmpty(1),
eUnknown(2),
eDiskDrive(8),
eIOCard(12)
}
ACCESS read-only
STATUS optional
DESCRIPTION
"Returns an indication of the type of option installed in
MIO/EIO slot 2. See SIMM1-TYPE for an explanation of the
enumerations."
::= { mio2 4 }
mio3-model-name OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS optional
DESCRIPTION
"Returns product information identifying the I/O card. Example:
XXXX."
::= { mio3 2 }
mio3-manufacturing-info OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS optional
DESCRIPTION
"Returns information describing the manufacture of the I/O card
installed in MIO/EIO interface 3. May include serial number and
firmware revision.
Additional information:
The format of the string returned is determined by
the manufacturer of the EIO device. There is no standard for
content of the string."
::= { mio3 3 }
mio3-type OBJECT-TYPE
SYNTAX INTEGER {
eEmpty(1),
eUnknown(2),
eDiskDrive(8),
eIOCard(12)
}
ACCESS read-only
STATUS optional
DESCRIPTION
"Returns an indication of the type of option installed in
MIO/EIO interface 3. See SIMM1-TYPE for an explanation of the
enumerations."
::= { mio3 4 }
io-timeout OBJECT-TYPE
SYNTAX INTEGER(5..300)
ACCESS read-write
STATUS optional
DESCRIPTION
"The amount of time, in seconds, to wait for more print job data
to be received before an I/O timeout occurs. The I/O channel
being timed is the I/O channel that received the data
associated with the current print job. If an I/O timeout
occurs, the PDL processing sub-system assumes all the data
associated with the current print job has been received, and
processes the end of job in a PDL specific manner. The POS
specifies the supported values.
Additional information:
If an I/O timeout occurs,the PDL processing
sub-system will consider it an end of job condition only
if there is data from another I/O subsystem waiting to be
processed.
The supported values are 5 to 300 seconds.
Setting to a value outside the supported range returns
<noError> status and the
value will be snapped to the nearest supported value."
::= { settings-io 1 }
io-switch OBJECT-TYPE
SYNTAX INTEGER {
eYes(1)
}
ACCESS read-only
STATUS optional
DESCRIPTION
"Indicates if the device will switch between I/O channels when a
job boundary is encountered and print job data is available on
another I/O channel."
::= { settings-io 2 }
port1-parallel-speed OBJECT-TYPE
SYNTAX INTEGER {
eSlow(1),
eFast(2)
}
ACCESS read-write
STATUS optional
DESCRIPTION
"Returns or changes the maximum parallel I/O port speed, for
port 1. This object is only supported if this port is a
parallel port. An eSlow setting causes a 10 us busy pulse per
received byte of data. An eFast setting causes a 1.5 us busy
pulse per received byte of data. In rare cases, setting this
value to eFast can cause the parallel port to no longer
transfer data reliably.
Additional information:
When the value of this object is changed, it takes
effect immediately. It is recommended that the printer
be offline and not in a job when this object is changed."
::= { port1 4 }
port1-parallel-bidirectionality OBJECT-TYPE
SYNTAX INTEGER {
eUnidirectional(1),
eBidirectional(2)
}
ACCESS read-write
STATUS optional
DESCRIPTION
"Returns or changes whether the parallel I/O port supports
bidirectional communication for port 1. This object is only
supported if this port is a parallel port.
Additional information:
A get on this object returns the current mode
for the parallel port. Setting this object specifies whether
or not bidirectional communications will be allowed."
::= { port1 5 }
channelnumberofchannels OBJECT-TYPE
SYNTAX INTEGER
ACCESS write-only
STATUS optional
DESCRIPTION
"An indication of how many print data channels the I/O card
supports.
Additional information:
This object is used by the IIO card to tell the peripheral
firmware how many logical channels will be used by the card.
This object can only be set once per physical channel. If
an attempt is made to set it a subsequent time it is ignored
and an return code of <ErrorActionCanNotBePerformedNow.is returned.
If new firmware is dynamically downloaded to the Blazers Plus
card, and if that firmware uses more logical channels, it is
necessary to reset the printer."
::= { channel 1 }
channelTable OBJECT-TYPE
SYNTAX SEQUENCE OF ChannelEntry
ACCESS not-accessible
STATUS optional
::= { channel 3 }
channelEntry OBJECT-TYPE
SYNTAX ChannelEntry
ACCESS not-accessible
STATUS optional
INDEX { channelindex }
::= { channelTable 1 }
ChannelEntry ::= SEQUENCE {
channelindex INTEGER,
channeltype INTEGER,
channelprotocolversion OCTET STRING,
channelstate INTEGER,
channelifindex INTEGER,
channelstatus INTEGER,
channelinformation OCTET STRING
}
channeltype OBJECT-TYPE
SYNTAX INTEGER {
eChOther(1),
eChAppleTalkPAP(7),
eChLPDServer(8),
eChNetwareRPrinter(9),
eChNetwarePServer(10),
eChPort9100(11),
eChDLCLLCPort(15),
eChBidirPortTCP(38)
}
ACCESS write-only
STATUS optional
DESCRIPTION
"Identifies the type of MIO print data channel.
Additional information:
After telling the peripheral how many logical channels will
be used, the IIO card tells the printer the type of each of
the channels. The type information is passed using the
channelType object. Values are then saved by the peripheral
and reported when users request the value of
prtChannelType."
::= { channelEntry 2 }
channelprotocolversion OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS write-only
STATUS optional
DESCRIPTION
"The version of the protocol used on this MIO print data
channel.
Additional information:
After telling the peripheral how many logical channels will
be used, the IIO card tells the printer the protocol version
of each of the channels. The protocol version information is
passed using the channelProtocolVersion object. Values are
then saved by the peripheral and reported when users request
the value of prtChannelProtocolVersion."
::= { channelEntry 3 }
channelstate OBJECT-TYPE
SYNTAX INTEGER {
eChOther(1),
eChPrintDataAccecped(3),
eChNoDataAccepted(4)
}
ACCESS write-only
STATUS optional
DESCRIPTION
"The state of this print data channel. The value determines
whether control information and print data is allowed through
this channel or not.
Additional information:
After telling the peripheral how many logical channels will
be used, the IIO card tells the printer the state of each of
the channels. The state can change from time to time. The
state information is passed using the channelState object.
Values are saved by the peripheral and reported when users
request the value of prtChannelState."
::= { channelEntry 4 }
channelifindex OBJECT-TYPE
SYNTAX INTEGER
ACCESS write-only
STATUS optional
DESCRIPTION
"The value of ifIndex which corresponds to this channel.
Additional information:
After telling the peripheral how many logical channels will
be used, the IIO card tells the printer the value of the
IfIndex for each channel. The IfIndex is used as part of
MIB-II. The values are saved by the peripheral and reported
when users request the value of prtChannelIfIndex."
::= { channelEntry 5 }
channelstatus OBJECT-TYPE
SYNTAX INTEGER
ACCESS write-only
STATUS optional
DESCRIPTION
"Sub-unit status is reported in the entries of the principle
table in the Group that represents the sub-unit. For sub-units
that report a status, there is a status column in the table and
the value of this column is always an integer formed in the
following way. The SubUnitStatus is an integer that is the sum
of 5 distinct values, Availability, Non-Critical, Critical,
On-line, and Transitioning. These values are:
Availability value
Available and Idle 0 000'b
Available and Standby 2 010'b
Available and Active 4 100'b
Available and Busy 6 110'b
Unavailable and OnRequest 1 001'b
Unavailable because Broken 3 011'b
Unknown 5 101'b
Non-Critical
No Non-Critical Alerts 0
Non-Critical Alerts 8
Critical
No Critical Alerts 0
Critical Alerts 16
On-Line
Intended state is On-Line 0
Intended state is Off-Line 32
Transitioning
At intended state 0
Transitioning to intended state 64.
Additional information:
After telling the peripheral how many logical channels will
be used, the IIO card tells the printer the status of each of
the channels. The status can change from time to time. The
status information is passed using the channelStatus object.
Values are saved by the peripheral and reported when users
request the value of prtChannelStatus."
::= { channelEntry 6 }
channelinformation OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS write-only
STATUS optional
DESCRIPTION
"Auxiliary information to allow a printing application to use
the channel for data submission to the printer. An application
capable of using a specific PrtChannelType should be able to
use the combined information from the prtChannelInformation and
other channel and interface group objects to 'bootstrap' its
use of the channel. prtChannelInformation is not intended to
provide a general channel description, nor to provide
information that is available once the channel is in use. The
encoding and interpretation of the prtChannelInformation object
is specific to channel type. The description of each
prtChannelType enum value for which prtChannelInformation is
defined specifies the appropriate encoding and interpretation,
including interaction with other objects. For channel types
that do not specify a prtChannelInformation value, its value
shall be null (0 length). When a new prtChannelType enumeration
value is registered, its accompanying description must specify
the encoding and interpretation of the prtChannelInformation
value for the channel type. prtChannelInformation semantics for
an existing PrtChannelType may be added or amended in the same
manner as described in section 2.4.1 for type 2 enumeration
values. The prtChannelInformation specifies values for a
collection of channel attributes, represented as text according
to the following rules:
1. The prtChannelInformation is coded in the NVT ASCII
character set. It is not affected by localization.
2. The prtChannelInformation is a list of entries
representing the attribute values. Each entry consists
of the following items, in order:
a. a keyword, composed of alphabetic characters (A-Z, a-z),
that identifies a channel attribute,
b. an Equals Sign (=) to delimit the keyword,
c. a data value, consisting of NVT ASCII graphics
characters (codes 32-126),
d. a Line Feed character (code 10) to delimit the data
value.
No other characters shall be present. Keywords are
case-sensitive. Conventionally, keywords are
capitalized (including each word of a multi-word
keyword), and, since they occupy space in the
prtChannelInformation, they are kept short.
3. If a channel attribute has multiple values, it is
represented by multiple entries with the same keyword,
each specifying one value. Otherwise, there shall be at
most one entry for each attribute.
4. By default, entries may appear in any order. If there
are ordering constraints for particular entries, these
must be specified in their definitions.
5. The prtChannelInformation value may represent
information that is not normally coded in textual form,
or that is coded in a character set other than NVT
ASCII. In these cases, whatever symbolic representation
is conventionally used for the information should be
used for encoding the prtChannelInformation. (For
instance, a binary port value might be represented as a
decimal number, Unicode would be represented in UTF-8
format.)
6. For each PrtChannelType for which prtChannelInformation
entries are defined, the descriptive text associated
with the PrtChannelType enumeration value shall specify
the following information for each entry:
Title: Brief description phrase, e.g.: 'Port name,'Service
Name,'
Keyword: The keyword value, eg: 'Port,' 'Service' Syntax:
The encoding of the entry value, if it cannot be
directly represented by NVT ASCII,
Status: 'Mandatory,' 'Optional,' or 'Conditionally
Mandatory,'
Multiplicity: 'Single' or 'Multiple,' to indicate whether
the entry may be present multiple times,
Description: Description of the use of the entry, other
information required to complete the definition (e.g.:
ordering contstraints, interactions between entries).
Applications that interpret prtChannelInformation should ignore
unrecognized entries, so they are not affected if new entry
types are added.
Additional information:
After telling the peripheral how many logical channels will
be used, the IIO card tells the printer the value of the information
value of each of the channels. The information is auxiliary
information used in conjunction with the channel Type."
::= { channelEntry 7 }
deviceChannelTable OBJECT-TYPE
SYNTAX SEQUENCE OF DeviceChannelEntry
ACCESS not-accessible
STATUS optional
::= { tables 2 }
deviceChannelEntry OBJECT-TYPE
SYNTAX DeviceChannelEntry
ACCESS not-accessible
STATUS optional
INDEX { channel-index }
::= { deviceChannelTable 1 }
DeviceChannelEntry ::= SEQUENCE {
channel-index INTEGER,
channel-bytes-sent INTEGER,
channel-bytes-received INTEGER,
channel-io-errors INTEGER,
channel-jobs-received INTEGER,
channel-mio INTEGER
}
channel-bytes-sent OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION
"The low order 31 bits of the number of bytes sent from the
printer to the host on this logical channel."
::= { deviceChannelEntry 2 }
channel-bytes-received OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION
"The low order 31 bits of the number of bytes received by the
printer from the host on this logical channel."
::= { deviceChannelEntry 3 }
channel-io-errors OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION
"The low order 31 bits of the number of I/O errors which have
occured on this logical channel."
::= { deviceChannelEntry 4 }
channel-jobs-received OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION
"The low order 31 bits of the number of print jobs which have
been received on this logical channel."
::= { deviceChannelEntry 5 }
channel-mio OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION
"The number of the MIO card associated with this logical
channel. If this logical channel is not associated with an MIO
card a zero is returned. The value returned for each logical
channel is the MIO card's physical slot number. The list of
supported values should be documented in the device POS.
Additional information:
The value returned will be zero for channels 1..3.
If an MIOA card is installed, channels 4..10 will
return a value of one or two.
If an MIOB card is installed, channels 11..17 will
return a value of one or two but not the
same as channels 4..10.
When two IIO cards are installed, the value
returned by any channel 4..17 may change after the
printer is power cycled."
::= { deviceChannelEntry 6 }
rpc-bind-protocol-address OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-only
STATUS optional
DESCRIPTION
"Array of Berkeley sockets style protocol addresses used to bind
RPC to a communications protocol family. Setting an instance of
this array object to a zero length binary value disables the
transport protocol indicated by that instance. All multi-bytes
fields are in network (or big-endian) order. Bytes 1 and 2
indicate the transport protocol. Some of the transport protocol
mapping information can be found in RFC 1010 Assigned Numbers.
A list of interesting transport protocol number mappings
include:
<table>
Protocol | Number
---------+-------
UDP/IP | 17
IPX | 1000
MLC | 4660
</table>
Bytes 3 and 4 indicate the address family. The address
family uses the same mapping as the BSD sockets address
family. A list of interesting address family mappings
include:
<table>
Address Family | Number
---------------+-------
Internet | 2
NetWare | 6
MLC | 22136
</table>
The format the fifth and following bytes is dependent on the
address family. For the Internet address family, bytes 5 and 6
contain the port number, bytes 7 through 10 contain the IP
address, and the following eight bytes are unused. For NetWare,
bytes 5 through 8 are the network number, bytes 9 through 14
are the node number, and bytes 15 and 16 are the socket
number.
Additional information:
The length of the binary value is zero
if the instance of an object in the rpc-bind-protocol-address
array is not in use.
Returns <noSuchName>
status if attempting to access this object and there
is no storage device is installed."
::= { settings-rpc 2 }
rpc-bound-protocol-address OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-only
STATUS optional
DESCRIPTION
"An array of Berkeley sockets style protocol addresses that the
NFS service has been bound to successful. The format is that
same as the array of RPC-BIND-PROTOCOL-ADDRESS of objects.
Additional information:
Returns <noSuchName>
status if attempting to access this object and there
is no storage device is installed."
::= { status-rpc 3 }
file-system-max-open-files OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION
"The number of open files allowed at one time. Opening a file
when the maximum number of files are currently open will fail.
Additional information:
Indicates the number of open files a
personality (e.g. PCL or PostScript) is guaranteed to be
able to open before the file system runs out of file handles.
This object is between 1 and 500.
Returns <noSuchName>
status if attempting to access this object and there
is no storage device is installed."
::= { settings-file-system 2 }
file-system-set-system-partition-writeable OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS write-only
STATUS optional
DESCRIPTION
"This object allows the system partition to be written to. It
consists of a C structure containing the following fields:
typedef struct {
ubyte password[8];
ubyte volumenumber;
} fs_writeable_system_partition_t;
which is described below:
Bytes 0 - 7: contain the password
Byte 8 : is the volume number
Access to this command is controlled by the password. If the
password supplied is incorrect the command will fail. The
volumenumber is a volume number of an existing system
partition.
Additional information:
Returns <noSuchName>
status if attempting to access this object and there
is no storage device is installed.
Returns <badValue> if the password is incorrect or if
the volume requested is not present."
::= { settings-file-system 6 }
file-system-set-system-partition-readonly OBJECT-TYPE
SYNTAX INTEGER
ACCESS write-only
STATUS optional
DESCRIPTION
"Changes a system partition to be READ-ONLY. The value is the
volume number to change. If the volume number specified is NOT
a system partition an error is returned.
Additional information:
Returns <noSuchName>
status if attempting to access this object and there
is no storage device is installed.
Returns <badValue> if the volume requested
is not present."
::= { settings-file-system 7 }
file-system-delete-files OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS write-only
STATUS optional
DESCRIPTION
"Setting this object causes the specified filename to be
deleted, after first validating that the authentication data is
correct for the specified user ID.
The format for this object is a C structure:
typedef struct {
sint32 UserId;
uint16 AuthenticationDataLen
ubyte AuthenticationData[]
char Filename[];
} fs_delete_files_t;
which is described below:
Bytes 0 - 3: contains a user id represented as a multi-byte
value that is stored in big-endian format, where the
most significant byte occurs first.
Bytes 4 - 5 : Length of the Athentication data that follows
starting at offset 6. Stored as a multi-byte value that
is stored in big-endian format, where the most
significant byte occurs first.
Bytes 6 - 6+AuthenticationDataLen : a ubyte array
containing the Authentication data used to verify
access for this operation.
Bytes starting at offset (6+AuthenticationDataLen+1): A
null terminated character array representing the ASCII
file name to be deleted. The length of the string will
be limited by the remaining space in the object.
This string represents a fully-qualified path name which may
specify a filename or a regular expression that may match
multiple files (e.g <path>/*.exe). Access to this command is
controlled by the UserId and the authentication data. If the
UserID or authentication data supplied is incorrect the command
will fail. The device POS will specify any limitations to the
length of the filename string, what constitutes a correct user
ID, what constitutes correct authentication data, and the
significance of any return values.
Additional information:
Setting this object causes the specified filename
to be deleted, after first validating that the
authentication data is correct for the specified
user ID. This object is always present.
The format for this object is a C structure:
typedef struct {
sint32 UserId;
uint16 AuthenticationDataLen
ubyte AuthenticationData[]
char Filename[];
} fs_delete_files_t;
Bytes 0 - 3: contains a user id represented
as a multi-byte value that is stored in big-endian
format, where the most significant byte occurs first.
Bytes 4 - 5 : Length of the authentication data that
follows starting at offset 6. Stored as a multi-byte
value that is stored in big-endian format, where the
most significant byte occurs first.
Bytes 6 - 6+AuthenticationDataLen : a ubyte array
containing the authentication data used to verify
access for this operation.
Bytes starting at offset (6+AuthenticationDataLen+1):
A null terminated character array representing the
ASCII file name to be deleted. The length of the
string will be limited by the remaining space in the
object. This string represents a fully-qualified path
name which may specify a filename or a file-type regular
expression that may match multiple files (e.g.,
<path>/*.exe).
Access to this command is controlled by the UserId
and the authentication data. If the UserID or
authentication data supplied is incorrect the
command will fail.
The device POS will specify any limitations to the
length of the filename string, what constitutes a
correct user ID, what constitutes correct
authentication data, and the significance of any
return values."
::= { settings-file-system 8 }
file-system2-initialize-volume OBJECT-TYPE
SYNTAX INTEGER {
eInitializing(2)
}
ACCESS write-only
STATUS optional
DESCRIPTION
"Setting this object to eInitializing causes file system 2 to be
initialized. Reading this object indicates if the file system
is currently being initialized.
Additional information:
The hrDeviceIndex value for the mass storage
device is the same value that is used to index into the
FILE-SYSTEM sub-tree. Since this product supports
up to 3 physical mass storage device, and since the hrDeviceIndex
for the mass storage devices will start at 2 if the mass
storage device is installed, the FILE-SYSTEM2-INITIALIZE-VOLUME
object will be the object that allows the mass storage device to be
initialized that is the 1st device."
::= { file-system2 6 }
file-system3-initialize-volume OBJECT-TYPE
SYNTAX INTEGER {
eInitializing(2)
}
ACCESS write-only
STATUS optional
DESCRIPTION
"Setting this object to eInitializing causes file system 3 to be
initialized. Reading this object indicates if the file system
is currently being initialized.
Additional information:
The hrDeviceIndex value for the mass storage
device is the same value that is used to index into the
FILE-SYSTEM sub-tree. Since this product supports
up to 3 physical mass storage device, and since the hrDeviceIndex
for the mass storage devices will start at 2 if the mass
storage device is installed, the FILE-SYSTEM3-INITIALIZE-VOLUME
object will be the object that allows the mass storage device to be
initialized that is the 2nd device."
::= { file-system3 6 }
file-system4-initialize-volume OBJECT-TYPE
SYNTAX INTEGER {
eInitializing(2)
}
ACCESS write-only
STATUS optional
DESCRIPTION
"Setting this object to eInitializing causes file system 4 to be
initialized. Reading this object indicates if the file system
is currently being initialized.
Additional information:
The hrDeviceIndex value for the mass storage
device is the same value that is used to index into the
FILE-SYSTEM sub-tree. Since this product supports
up to 3 physical mass storage devices, and since the hrDeviceIndex
for the mass storage devices will start at 2 if the mass
storage device is installed, the FILE-SYSTEM4-INITIALIZE-VOLUME
object will be the object that allows the mass storage device to be
initialized that is the 3rd device."
::= { file-system4 6 }
mass-storage-resource-change-counter OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION
"A counter which changes when a mass storage based resource has
been added or deleted.
Additional information:
The value of this counter changes
each time the MASS-STORAGE-RESOURCE-CHANGED object
is set to eTrue. The value also changes when the
mass storage device is initialized. However, the value does not
change when a mass storage device is removed and a different
mass storage device is installed. Initializing all volumes sets
this object back to the factory default value. A reboot sets
this object back to the factory devalut value.
Returns <noSuchName>
status if attempting to access this object and there
is no storage device is installed."
::= { mass-storage-resources 1 }
mass-storage-resource-changed OBJECT-TYPE
SYNTAX INTEGER {
eTrue(2)
}
ACCESS write-only
STATUS optional
DESCRIPTION
"Setting to eTrue causes MASS-STORAGE-RESOURCE-CHANGE-COUNTER to
be incremented.
Additional information:
Returns <noSuchName>
status if attempting to access this object and there
is no storage device is installed."
::= { mass-storage-resources 2 }
ram-disk-mode OBJECT-TYPE
SYNTAX INTEGER {
eOff(1),
eAuto(3)
}
ACCESS read-write
STATUS optional
DESCRIPTION
"Returns or controls RAM disk support. eOFF turns off the RAM
disk functionality. eOn turns on the RAM disk functionality and
creates a RAM disk whose size is controlled by the
RAM-DISK-SIZE object. eAuto turns on the RAM disk functionality
and creates a RAM disk size determined by the printer based on
installed options and other memory related settings.
Additional information:
Returns or controls RAM disk support. eOFF turns off
the RAM disk functionality. eAuto turns on
the RAM disk functionality and creates a RAM disk size
determined by the printer based on the amount of installed
memory."
::= { settings-mass-storage-bd 1 }
ram-disk-size OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION
"Returns or controls the size of the RAM disk. The device POS
specifies the minimum memory requirements. The object
MAXIMUM-RAM-DISK-MEMORY specifies the maximum memory available
for the RAM disk.
Additional information:
Returns the size of the RAM disk."
::= { settings-mass-storage-bd 2 }
maximum-ram-disk-memory OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION
"This object's name is misleading. This object does not return
the maximum configurable RAM disk size. Instead, it returns the
maximum amount of memory, in bytes, that can used to increase
the size of the RAM disk.
Additional information:
This object returns the maximum amount of additional
memory that is available for increasing the size of the RAM
disk."
::= { status-mass-storage-bd 1 }
device-configure-print-engine-speed OBJECT-TYPE
SYNTAX INTEGER {
eNormal(1),
eSlowDown1(2)
}
ACCESS read-write
STATUS optional
DESCRIPTION
"Return or set the value of the print engine speed. Where
eNormal is the default speed and with each eSlowDownN setting
the printer gets progressively slower than the previous speed.
Additional information:
This object will only be registered once the
PE_TEST_PASSWORD is set. This object is used to
return or set the value for the engine's print speed.
This value is written to NVRAM and is persistant.
eNormal = Normal engine speed.
eSlowDown1 = Decreased engine speed."
::= { device-configure 5 }
device-configure-duplexer-enabled OBJECT-TYPE
SYNTAX INTEGER {
eDisabled(1),
eEnabled(2)
}
ACCESS read-write
STATUS optional
DESCRIPTION
"Return or set the value for the duplexer installed. eEnabled =
The duplexer is installed. eDisabled = The duplexer is not
installed.
Additional information:
This object will only be registered once the
PE_TEST_PASSWORD is set. This object is used to
return or set the value controlling the duplexer
This value is written to NVRAM and is persistant.
eDisabled = Disabled Duplexer.
eEnabled = Enabled Duplexer."
::= { device-configure 8 }
job-input-auto-continue-timeout OBJECT-TYPE
SYNTAX INTEGER(-1..3600)
ACCESS read-write
STATUS optional
DESCRIPTION
"The number of seconds the device waits after a job related
continuable error occurs before automatically continuing. An
example job related continuable error is the job requesting a
media size that is not available. After the timeout expires,
the device will continue processing the job as if a continue
event occurred, such as the front panel continue key being
pressed. If the value is -1, the device does not automatically
continue after a job related continuable error occurs. If the
value is 0, the device immediately continues. If the value is
greater than 0, the value represents the timeout value in
seconds.
Additional information:
This object is used only for media requests
(size and/or name). LaserJet 8150 supports any value in
the range of -1 to 3600. Setting to a value outside
of that range causes the printer to substitute a
value (listed below) and to return
<noError> status. The
values are as follow: <-1 snaps to -1
>3600 snaps to 3600 (60 minutes) The action that
occurs when this timeout expires is explained by
JOB-INPUT-AUTO-CONTINUE-MODE. It is not the same as
the CONTINUE object being set to eInitiateAction or
the Select key being pressed on the control panel.
See the CONTINUE object description for
information on the actions that occur for those
conditions.
The data for this object is stored in NVRAM."
::= { status-system 35 }
job-input-auto-continue-mode OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS optional
DESCRIPTION
"Returns or sets the device behavior when the desired media is
not currently available.
cCancelJob - The device cancels the job. The device POS
should explain what happens if this item is not the
only item in the collection.
cAutoMediaSizeOverride - The device is allowed to
substitute a different size media.
cAutoMediaNameOverride - The device is allowed to
substitute a different media name.
cUSMediaSizeOverride - The device is allowed to substitute
US media sizes (letter, etc.) for ISO media sizes (A4,
etc.).
cISOMediaSizeOverride - The device is allowed to substitute
ISO media sizes (A4, etc.) for US media sizes (letter,
etc.).
Additional information:
If cCancelJob is set, the current print job will
be canceled regardless of other item settings. At
least one bit of the collection must be set; setting
this object to zero will cause a status of
<badValue> to be returned.
This object applies to all media requests, including
Manual Feed Requests. This object describes the
action that is performed when the
JOB-INPUT-AUTO-CONTINUE-TIMEOUT expires. The action
performed by the CONTINUE object being set to
eInitiateAction or the GO key being pressed on the
control panel may cause different actions. See the
CONTINUE object description for information on the
actions that occur for those conditions.
The data for this object is stored in NVRAM."
::= { status-system 36 }
job-output-auto-continue-timeout OBJECT-TYPE
SYNTAX INTEGER(-1..3600)
ACCESS read-write
STATUS optional
DESCRIPTION
"Returns or sets the time that the printer will wait after an
output bin becomes full and the printer is trying to deliver a
sheet of media to that output bin. When the timeout expires,
the job is processed according to the OUTBINn-OVERRIDE-MODE. A
value of -1 indicates that the printer will wait for a continue
event. A non-negative value is the number of seconds to wait.
Additional information:
A value of zero means to continue immediately.
The value of this object is stored in NVRAM, so
it is maintained across a power cycle.
The data for this object is stored in NVRAM."
::= { status-system 40 }
model-number OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS optional
DESCRIPTION
"Identifies the device model number as listed in the HP
corporate price list (e.g. C2121A for DeskJet 500C). The string
is as specific as possible. Products should note in POS if the
model number on the CPL changes but the device reports the
previous model number. If the model number changes based on the
installed options, the POS should indicate if only the base
model number is returned, or if the device senses the installed
options and returns the correct model number. If possible,
encode the model number in a symbol set (like Roman-8) that
matches the ASCII character set and limit the characters used
to ASCII characters.
Additional information:
The value of this object does not change based on
the installed options. The default of this object is the
same on all LaserJet 8150 printers."
::= { id 1 }
model-name OBJECT-TYPE
SYNTAX DisplayString (SIZE(1..32))
ACCESS read-only
STATUS optional
DESCRIPTION
"Identifies the device model name (e.g. ''DeskJet 1200C''). The
string is as specific as possible. Capitalization and spacing
should match family naming conventions. Products should note in
POS if the model name on the HP corporate price list changes
but the device reports the previous device name. If the model
name changes based on the installed options, the POS should
indicate if only the base model name is returned, or if the
device senses the installed options and returns the correct
model name. If possible, encode the model name in a symbol set
(like Roman-8) that matches the ASCII character set and limit
the characters used to ASCII characters.
Additional information:
Since the value of this object is frequently used in
displaying a list of printers, it is kept relatively short in
case systems have limited width for their display area. The
model name does not change based on sensing of installed options."
::= { id 2 }
engine-self-diagnostic OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-only
STATUS optional
DESCRIPTION
"The ENGINE-SELF-DIAGNOSTIC object reveals current engine
failures; it returns a binary string of two-byte motor, clutch,
solenoid, and sensor failure codes.
Additional information:
The ENGINE-SELF-DIAGNOSTIC object reveals current
Engine Failures; it returns a BINARY string of two-byte
Motor, Clutch, Solenoid and Sensor failure codes."
::= { test 7 }
default-media-name OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-write
STATUS optional
DESCRIPTION
"Returns or sets the media name that is used until the media
name is changed by a print job command.
Additional information:
This string must be one of the MEDIAn-NAME
objects. The value of this object is saved across
a power cycle."
::= { settings-pdl 22 }
override-media-name OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-write
STATUS optional
DESCRIPTION
"Sets a string identifying the media name that is to be used in
place of the currently requested media. The substitution will
continue until another media is selected. If set to a named
media that is not currently available the requested media is
not overridden.
Additional information:
When a request is received to print on a size and
type of media that is not currently available, this
object contains the desired media name as set by the
print job. This object should be set to a media name
that is currently available in the printer. If a
paper mount request is not pending, attempting to get
or set this object will cause
<noSuchName> to be returned.
Setting this object to a string other than one of the
MEDIAn-NAME objects (MEDIA-NAMES-AVAILABLE is applied)
will cause a status of <badValue>
to be returned."
::= { settings-prt-eng 2 }
override-media-size OBJECT-TYPE
SYNTAX INTEGER {
eAnySize(32765),
eUSExecutive(1),
eUSLetter(2),
eUSLegal(3),
eLedger(11),
eROC16K(17),
eJISExecutive(18),
eROC8K(19),
eISOandJISA5(25),
eISOandJISA4(26),
eISOandJISA3(27),
eJISB5(45),
eJISB4(46),
eISOB5(65),
eJapanesePostcardDouble(72),
eMonarch(80),
eCommercial10(81),
eInternationalDL(90),
eInternationalC5(91),
eInternationalB5(100),
eCustom(101),
eUSLetterR(258),
eISOandJISA4R(282),
eUnknownMediaSize(32767)
}
ACCESS read-write
STATUS optional
DESCRIPTION
"Sets the media size that is to be used in place of the
currently requested media size.
Additional information:
When a request is received to print on a size and
type of media that is not currently available, this object
contains the desired size as set by the print job. This object
should be set to a media size that is currently available to the
printer. If a paper mount request is not pending, attempting to
get or set this object will cause <noSuchName>
to be returned."
::= { settings-prt-eng 3 }
print-density OBJECT-TYPE
SYNTAX INTEGER(1..5)
ACCESS read-write
STATUS optional
DESCRIPTION
"Returns or sets the print density setting. Print density is the
instantaneous amount of marking agent applied to the paper
while printing. A value of zero has the lowest print density,
yielding a lighter page. A value of 10 has the highest print
density, yielding a darker page. Each POS should document what
values in the 0 to 10 range are supported.
Additional information:
When this value is written, the page pipeline
will be flushed (all pages being printed are completed, no
new ones are started), the new density setting is set and
printing resumes. The acutal change in print density may be
gradual over several pages.
The supported values are 1 through 5. Setting to an
unsupported value causes the printer to substitue in a
a snap value and to return <noError>
status. The snap values are as follows:
<1 snaps to 1
>5 snaps to 5."
::= { settings-prt-eng 5 }
marking-agent-density-setting OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS optional
DESCRIPTION
"Returns or sets the marking agent density setting for each of
the marking agents installed. The Marking Agent (aka Print)
density is the instantaneous amount of marking agent applied to
the media while printing. A value of zero has the lowest print
density, yielding a lighter page. A value of 10 has the highest
print density, yielding a darker page. The device POS will
document what values are supported.
Additional information:
See the description for PRINT-DENSITY ."
::= { marking-agent-density 1 }
duplex-page-count OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION
"Total number of sheets of media that have been duplex printed.
A sheet is counted if it travels through the duplex page path,
regardless of whether or not marks are made on the page. The
POS will indicate if the value is kept in NVRAM.
Additional information:
In LaserJet 8150 the count is kept in
NVRAM however the NVRAM value is only updated every 10
sheets. NOTE: The value returned by this object will be
incremented every sheet but if power is lost between
NVRAM updates up to 9 sheets of the count may be
lost. The counter will be reset to zero
after 16,777,215 (2^24-1) pages. "
::= { status-prt-eng 22 }
print-engine-revision OBJECT-TYPE
SYNTAX DisplayString (SIZE(1..16))
ACCESS read-only
STATUS optional
DESCRIPTION
"Print engine revision string.
Additional information:
The symbol set for this string is Roman-8. Converts
engine revision number to a string and returns it."
::= { status-prt-eng 26 }
input-tray-auto-select OBJECT-TYPE
SYNTAX INTEGER {
eOff(1),
eOn(2)
}
ACCESS read-write
STATUS optional
DESCRIPTION
"Indicates if the device will automatically try to load media
from the next input media tray in the auto-select sequence
(defined by each device) when it cannot load media from the
current tray. Locked trays will not be permitted in the
auto-select sequence. This object has no meaning if there is
only one unlocked input media tray.
Additional information:
Indicates whether, when the requested input tray does
not contain suitable media, the printer will try to
auto-select another input tray that has usable media
loaded. If this object is set to eOff(1), then the
printer will not try to auto-select another tray and
will simply prompt the user to load the requested tray
with the requested media. If the object is set to eOn(2),
then auto-selection will be used to try to find another
suitable input tray."
::= { settings-intray 2 }
default-custom-paper-dim-unit OBJECT-TYPE
SYNTAX INTEGER {
eTenThousandthsOfInches(3),
eMicrometers(4)
}
ACCESS read-write
STATUS optional
DESCRIPTION
"The units of measure used to specify the width and height of
the printer's default custom paper size. The unit of measure of
eTenThousandthsOfInches is 0.0001 inches.
Additional information:
The units of measure used to specify the width and
height of the printer's default custom paper size.
The unit of measure of eTenThousandthsOfInches is
0.0001 inches."
::= { settings-intray 10 }
default-custom-paper-feed-dim OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS optional
DESCRIPTION
"Sets the printer's default custom paper size dimension in the
feed direction (direction parallel to the direction of paper
feeding). The value for this object is specified in micrometers
or tenthousandths of an inch, depending upon the value of
DEFAULT-CUSTOM-PAPER-DIM-UNIT. The valid range is
engine-dependent and should be documented in the POS for each
product.
Additional information:
Sets the printer's default custom paper size dimension
in the feed direction (direction parallel to the direction
of paper feeding). The value for this object is specified
in micrometers or tenthousandths of an inch, depending upon
the value of DEFAULT-CUSTOM-PAPER-DIM-UNIT. The valid
range is engine-dependent and should be documented in the
POS for each product."
::= { settings-intray 11 }
default-custom-paper-xfeed-dim OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS optional
DESCRIPTION
"Sets the printer's default custom paper size dimension in the
cross-feed direction (direction ninety degrees relative to the
direction of paper feeding). The value for this object is
specified in micrometers or tenthousandths of an inch,
depending upon the value of DEFAULT-CUSTOM-PAPER-DIM-UNIT. The
valid range is engine-dependent and should be documented in the
POS for each product.
Additional information:
Sets the printer's default custom paper size dimension
in the cross-feed direction (direction ninety degrees
relative to the direction of paper feeding). The value
for this object is specified in micrometers or
tenthousandths of an inch, depending upon the value of
DEFAULT-CUSTOM-PAPER-DIM-UNIT. The valid range is
engine-dependent and should be documented in the POS
for each product."
::= { settings-intray 12 }
input-tray-max-media-feed-dim OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION
"The maximum physical media size in the feed direction of this
input device expressed in units of measure specified by INPUT-
TRAY-MIN-MAX-DIM-UNIT. A value of (-1) implies 'unlimited', a
value of (-2) implies 'unknown'.
Additional information:
The maximum physical media size in the feed direction of this
input device expressed in units of measure specified by
PrtInputDimUnit. A value of (-1) implies 'unlimited', a value of
(-2) implies 'unknown'. Refer to Printer Management Standards web
page, http://bldlabs.boi.hp.com/BLDPrinterLab/Project/PrinterManagement,
for more details in the original format of the Standard Printer
MIB."
::= { settings-intray 14 }
input-tray-max-media-xfeed-dim OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION
"The maximum physical media size across the feed direction of a
particular input device expressed in units of measure specified
by INPUT-TRAY-MIN-MAX-DIM-UNIT. A value of (-1) implies
'unlimited', a value of (-2) implies 'unknown'.
Additional information:
The maximum physical media size across the feed direction of this
input device expressed in units of measure specified by
PrtInputDimUnit. A value of (-1) implies 'unlimited',
a value of (-2) implies 'unknown'.
Refer to Printer Management Standards web page,
http://bldlabs.boi.hp.com/BLDPrinterLab/Project/PrinterManagement,
for more details in the original format of the Standard Printer
MIB."
::= { settings-intray 15 }
input-tray-min-media-feed-dim OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION
"The minimum physical media size in the feed direction of a
particular input device expressed in units of measure specified
by PrtInputMinMaxDimUnit. A value of (-1) implies 'unlimited',
a value of (-2) implies 'unknown'.
Additional information:
The minimum physical media size in the feed direction of this
input device expressed in units of measure specified by
PrtInputDimUnit. A value of (-1) implies 'unlimited',
a value of (-2) implies 'unknown'.
Refer to Printer Management Standards web page,
http://bldlabs.boi.hp.com/BLDPrinterLab/Project/PrinterManagement,
for more details in the original format
of the Standard Printer MIB."
::= { settings-intray 16 }
input-tray-min-media-xfeed-dim OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION
"The minimum physical media size across the feed direction of a
particular input device expressed in units of measure specified
by PrtInputMinMaxDimUnit. A value of (-1) implies 'unlimited',
a value of (-2) implies 'unknown'.
Additional information:
The minimum physical media size across the feed direction of this
input device expressed in units of measure specified by
PrtInputDimUnit. A value of (-1) implies 'unlimited',
a value of (-2) implies 'unknown'.
Refer to Printer Management Standards web page,
http://bldlabs.boi.hp.com/BLDPrinterLab/Project/PrinterManagement,
for more details in the original format
of the Standard Printer MIB."
::= { settings-intray 17 }
tray1-media-size-loaded OBJECT-TYPE
SYNTAX INTEGER {
eAnySize(32765),
eUSExecutive(1),
eUSLetter(2),
eUSLegal(3),
eROC16K(17),
eJISExecutive(18),
eISOandJISA5(25),
eISOandJISA4(26),
eJISB5(45),
eISOB5(65),
eJapanesePostcardDouble(72),
eMonarch(80),
eCommercial10(81),
eInternationalDL(90),
eInternationalC5(91),
eInternationalB5(100),
eCustom(101),
eAnyCustom(32764)
}
ACCESS read-write
STATUS optional
DESCRIPTION
"Returns the media size that is currently configuredconfigured
in tray #1. This object can be set to indicate the media size
currently loaded, if the printer supports input trays that can
not sense the media size. Complete list of supported media
sizes along with their dimensions are listed in the ''Media
Size Table'' near the end of this document."
::= { intray1 1 }
tray1-phd OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION
"Provides the number of the Paper Handling Device that contains
this input tray.
Additional information:
The internal trays belong to device 0, which is the
base engine. The envelope feeder (if supported) is
considered to be device 1 and the external input devices
can number between 2 and 6 depending on individual
user configurations."
::= { intray1 12 }
tray2-media-size-loaded OBJECT-TYPE
SYNTAX INTEGER {
eAnySize(32765),
eUSExecutive(1),
eUSLetter(2),
eUSLegal(3),
eROC16K(17),
eJISExecutive(18),
eISOandJISA5(25),
eISOandJISA4(26),
eJISB5(45),
eISOB5(65)
}
ACCESS read-write
STATUS optional
DESCRIPTION
"Returns the media size that is currently configured in tray #2.
Complete list of supported media sizes along with their
dimensions are listed in the ''Media Size Table'' near the end
of this document.
Additional information:
If the tray drawer is open, a get on this object
will cause a status of
<genErr> to be
returned. If the tray is empty, the size that the
tray is configured for will be returned. If Tray 2
is a 500-sheet standard tray, eJISB5 and eUSExecutive
are not valid values."
::= { intray2 1 }
tray2-phd OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION
"Provides the number of the Paper Handling Device that contains
this input tray."
::= { intray2 12 }
tray3-media-size-loaded OBJECT-TYPE
SYNTAX INTEGER {
eAnySize(32765),
eUSLetter(2),
eISOandJISA4(26)
}
ACCESS read-write
STATUS optional
DESCRIPTION
"Returns the media size that is currently configured in tray #3.
Complete list of supported media sizes along with their
dimensions are listed in the ''Media Size Table'' near the end
of this document.
Additional information:
If the tray drawer is open, a get on this object
will cause a status of
<genErr> to be
returned. If the tray is empty, the size that the
tray is configured for will be returned."
::= { intray3 1 }
tray3-phd OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION
"Provides the number of the Paper Handling Device that contains
this input tray."
::= { intray3 12 }
overflow-bin OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS optional
DESCRIPTION
"Returns or sets the bin that will be used for additional sheets
of media when the current bin is full and printing is allowed
to continue.
Additional information:
The data for this object is stored in NVRAM."
::= { settings-outbin 4 }
outbin1-override-mode OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS optional
DESCRIPTION
"Returns or sets the device behavior when this output bin
condition causes printing to stop.
cCancelJob - The device cancels the job.
cOutbinFullOverride - The device sends subsequent media to
the overflow bin.
cOutbinAttentionOverride - The device ignores the attention
condition and continues printing.
cBinderAttentionOverride - The device ignores the binder
attention condition and continues printing.
Additional information:
If cCancelJob is set, the current print job will
be cancelled regardless of other item settings.
If cOutbinFullOverride is set and this bin is the
designated overflow bin (OVERFLOW-BIN = 1), then the
bit is ignored. This object describes the action
that is performed when the
JOB-OUTPUT-AUTO-CONTINUE-TIMEOUT expires. If no bits
are set, no override action is taken (the printer
will continue to wait).
The action performed by the CONTINUE object being set
to eInitiateAction or the GO key being pressed on the
control panel may cause different actions. See the
CONTINUE object description for information on the
actions that occur for those conditions."
::= { outbin1 9 }
phd2-device-specific-command OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS write-only
STATUS optional
DESCRIPTION
"This object is used to send device-specific data to the paper
handling device. The meaning of the device-specific command is
dependent on the paper handling device and must be specified in
the POS. If the paper handling device does not accept the
command, then an <badValue> will be
returned. If the device accepts the command, it may still be
processing the command after the response has been returned.
Depending on the device, the application may need to query
PHDx-DEVICE-MEMORY to see when the command has completed.
Additional information:
This object is used to send device-specific data to the
paper handling device. The meaning of the device-
specific command is dependent on the paper handling
device and must be specified in the POS.
If the paper handling device does not accept the
command, then an <badValue> will
be returned. If the device accepts the command, it may
still be processing the command after the response has
been returned. Depending on the device, the application
may need to query PHDx-DEVICE-MEMORY to see when the
command has completed."
::= { ph2 2 }
phd3-device-specific-command OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS write-only
STATUS optional
DESCRIPTION
"This object is used to send device-specific data to the paper
handling device. The meaning of the device-specific command is
dependent on the paper handling device and must be specified in
the POS. If the paper handling device does not accept the
command, then an <badValue> will be
returned. If the device accepts the command, it may still be
processing the command after the response has been returned.
Depending on the device, the application may need to query
PHDx-DEVICE-MEMORY to see when the command has completed.
Additional information:
This object is used to send device-specific data to the
paper handling device. The meaning of the device-
specific command is dependent on the paper handling
device and must be specified in the POS.
If the paper handling device does not accept the
command, then an <badValue> will
be returned. If the device accepts the command, it may
still be processing the command after the response has
been returned. Depending on the device, the application
may need to query PHDx-DEVICE-MEMORY to see when the
command has completed."
::= { ph3 2 }
phd4-device-specific-command OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS write-only
STATUS optional
DESCRIPTION
"This object is used to send device-specific data to the paper
handling device. The meaning of the device-specific command is
dependent on the paper handling device and must be specified in
the POS. If the paper handling device does not accept the
command, then an <badValue> will be
returned. If the device accepts the command, it may still be
processing the command after the response has been returned.
Depending on the device, the application may need to query
PHDx-DEVICE-MEMORY to see when the command has completed.
Additional information:
This object is used to send device-specific data to the
paper handling device. The meaning of the device-
specific command is dependent on the paper handling
device and must be specified in the POS.
If the paper handling device does not accept the
command, then an <badValue> will
be returned. If the device accepts the command, it may
still be processing the command after the response has
been returned. Depending on the device, the application
may need to query PHDx-DEVICE-MEMORY to see when the
command has completed."
::= { ph4 2 }
phd5-device-specific-command OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS write-only
STATUS optional
DESCRIPTION
"This object is used to send device-specific data to the paper
handling device. The meaning of the device-specific command is
dependent on the paper handling device and must be specified in
the POS. If the paper handling device does not accept the
command, then an <badValue> will be
returned. If the device accepts the command, it may still be
processing the command after the response has been returned.
Depending on the device, the application may need to query
PHDx-DEVICE-MEMORY to see when the command has completed.
Additional information:
This object is used to send device-specific data to the
paper handling device. The meaning of the device-
specific command is dependent on the paper handling
device and must be specified in the POS.
If the paper handling device does not accept the
command, then an <badValue> will
be returned. If the device accepts the command, it may
still be processing the command after the response has
been returned. Depending on the device, the application
may need to query PHDx-DEVICE-MEMORY to see when the
command has completed."
::= { ph5 2 }
phd6-device-specific-command OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS write-only
STATUS optional
DESCRIPTION
"This object is used to send device-specific data to the paper
handling device. The meaning of the device-specific command is
dependent on the paper handling device and must be specified in
the POS. If the paper handling device does not accept the
command, then an <badValue> will be
returned. If the device accepts the command, it may still be
processing the command after the response has been returned.
Depending on the device, the application may need to query
PHDx-DEVICE-MEMORY to see when the command has completed.
Additional information:
This object is used to send device-specific data to the
paper handling device. The meaning of the device-
specific command is dependent on the paper handling
device and must be specified in the POS.
If the paper handling device does not accept the
command, then an <badValue> will
be returned. If the device accepts the command, it may
still be processing the command after the response has
been returned. Depending on the device, the application
may need to query PHDx-DEVICE-MEMORY to see when the
command has completed."
::= { ph6 2 }
media-names-available OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS optional
DESCRIPTION
"The value of this object controls which of the MEDIAx-NAME
objects are supported. If a bit is set to zero, then attempting
to get or set the corresponding MEDIAx-NAME objects will return
<noSuchName>.
Additional information:
Setting a bit to one will cause the corresponding
MEDIAn- objects to be available (attempting to access
an unavailable object will return <noSuchName>).
MEDIA1- objects are always present, as this is the default
media. If this object is set to a value that does not include
cMediaName1Available, that bit will be set and a status of
<noError> will be returned.
cMediaName12Available, cMediaName13Available, and
cMediaName14Available cannot be changed, as MediaName12,13, and
14 are not supported Media Names for Color LaserJet 2500. Attempts to set
these will cause <badValue> to be returned."
::= { settings-print-media 1 }
north-edge-offset OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS optional
DESCRIPTION
"Returns or sets the number of 300 dpi dots by which the image
is shifted. Shift is relative to the leading edge of the medium
as the medium flows through the marking engine with the side to
be imaged facing the observer. The leading edge is the North
edge and the other edges are defined by the normal compass
layout of directions with the compass facing the observer. The
adjustment is for all pages printed. A positive value moves the
image away from the leading edge of the medium. A negative
value moves the image closer to the leading edge of the medium.
The value 0 will return the image to its factory default
position.
Additional information:
Returns or sets the number of 300 dpi dots by which the image is
shifted. Shift is relative to the leading edge of the medium as
the medium flows through the marking engine with the side to be
imaged facing the observer. The leading edge is the North edge and
the other edges are defined by the normal compass layout of
directions with the compass facing the ob server. The adjustment
is for all pages printed. A positive value moves the image away
from the leading edge of the medium. A negative value moves the
image closer to the leading edge of the medium. The value 0 will
return the image to its factory default position. The value of
this object is stored in NVRAM."
::= { settings-print-media 2 }
media1-name OBJECT-TYPE
SYNTAX DisplayString (SIZE(1..24))
ACCESS read-only
STATUS optional
DESCRIPTION
"Media 1 name.
Additional information:
The symbol set for this string is Roman-8."
::= { media1 1 }
media1-short-name OBJECT-TYPE
SYNTAX DisplayString (SIZE(1..9))
ACCESS read-only
STATUS optional
DESCRIPTION
"Length restricted version of the media name 1. The length
restriction is required to allow the media name to be displayed
on the device's control panel. The device POS must state the
maximum number of characters allowed. If the device also has a
limitation on what characters in a character set can be used
(e.g. only uppercase characters allowed), the POS should also
state character restrictions.
Additional information:
The maximum supported string length is 9 characters. If
the user entered string is too long, the device will store
the first 9 characters and will return the
<noError> status.
The characters must be in the range 20H to 7FH except 5C
cannot be used. The default symbol set is Roman-8 for
English; additional legal symbol sets are ISOLatin5,
ISOLatin2 and Windows31J. Setting this object with characters
outside of the range or of an illegal symbol set will cause an
error status of <badValue> to be returned."
::= { media1 2 }
media1-page-count OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION
"Number of sheets of media 1 that have been printed. The device
POS should state whether this value is lost across a power
cycle or kept in NVRAM.
Additional information:
For LaserJet 8150 this page count is saved in NVRAM after every 10
pages. The maximum value is 4,294,967,295 which will never be
reached in normal operation.
The page count is incremented when a sheet of media is pulled from
an input tray. A duplex printed sheet will cause this counter to
be incremented by one.
The data for this object is stored in NVRAM."
::= { media1 3 }
media1-engine-media-mode OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS optional
DESCRIPTION
"The engine processing characteristics that are to be applied to
this media. The processing characteristics are device
specific.
Additional information:
The engine processing characteristics that are to
be applied to this media type. Currently, 'engine
processing characteristics' denotes changes to
fusing temperature and/or transfer roller voltage.
The data for this object is stored in NVRAM."
::= { media1 4 }
media2-name OBJECT-TYPE
SYNTAX DisplayString (SIZE(1..24))
ACCESS read-only
STATUS optional
DESCRIPTION
"Media 2 name.
Additional information:
See MEDIA1-NAME."
::= { media2 1 }
media2-short-name OBJECT-TYPE
SYNTAX DisplayString (SIZE(1..9))
ACCESS read-only
STATUS optional
DESCRIPTION
"Length restricted version of the media name 2. See
MEDIA1-SHORT-NAME for details.
Additional information:
See MEDIA1-SHORT-NAME."
::= { media2 2 }
media2-page-count OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION
"Number of sheets of media 2 that have been printed. See
MEDIA1-PAGE-COUNT for details.
Additional information:
See MEDIA1-PAGE-COUNT."
::= { media2 3 }
media2-engine-media-mode OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS optional
DESCRIPTION
"The engine processing characteristics that are to be applied to
this media. The processing characteristics are device
specific.
Additional information:
See the description for MEDIA1-ENGINE-MEDIA-MODE."
::= { media2 4 }
media3-name OBJECT-TYPE
SYNTAX DisplayString (SIZE(1..24))
ACCESS read-only
STATUS optional
DESCRIPTION
"Media 3 name.
Additional information:
See MEDIA1-NAME."
::= { media3 1 }
media3-short-name OBJECT-TYPE
SYNTAX DisplayString (SIZE(1..9))
ACCESS read-only
STATUS optional
DESCRIPTION
"Length restricted version of the media name 3. See
MEDIA1-SHORT-NAME for details.
Additional information:
See MEDIA1-SHORT-NAME."
::= { media3 2 }
media3-page-count OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION
"Number of sheets of media 3 that have been printed. See
MEDIA1-PAGE-COUNT for details.
Additional information:
See MEDIA1-PAGE-COUNT."
::= { media3 3 }
media3-engine-media-mode OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS optional
DESCRIPTION
"The engine processing characteristics that are to be applied to
this media. The processing characteristics are device
specific.
Additional information:
See the description for MEDIA1-ENGINE-MEDIA-MODE."
::= { media3 4 }
media4-name OBJECT-TYPE
SYNTAX DisplayString (SIZE(1..24))
ACCESS read-only
STATUS optional
DESCRIPTION
"Media 4 name.
Additional information:
See MEDIA1-NAME."
::= { media4 1 }
media4-short-name OBJECT-TYPE
SYNTAX DisplayString (SIZE(1..9))
ACCESS read-only
STATUS optional
DESCRIPTION
"Length restricted version of the media name 4. See
MEDIA1-SHORT-NAME for details.
Additional information:
See MEDIA1-SHORT-NAME."
::= { media4 2 }
media4-page-count OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION
"Number of sheets of media 4 that have been printed. See
MEDIA1-PAGE-COUNT for details.
Additional information:
See MEDIA1-PAGE-COUNT."
::= { media4 3 }
media4-engine-media-mode OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS optional
DESCRIPTION
"The engine processing characteristics that are to be applied to
this media. The processing characteristics are device
specific.
Additional information:
See the description for MEDIA1-ENGINE-MEDIA-MODE."
::= { media4 4 }
media5-name OBJECT-TYPE
SYNTAX DisplayString (SIZE(1..24))
ACCESS read-only
STATUS optional
DESCRIPTION
"Media 5 name.
Additional information:
See MEDIA1-NAME."
::= { media5 1 }
media5-short-name OBJECT-TYPE
SYNTAX DisplayString (SIZE(1..9))
ACCESS read-only
STATUS optional
DESCRIPTION
"Length restricted version of the media name 5. See
MEDIA1-SHORT-NAME for details.
Additional information:
See MEDIA1-SHORT-NAME."
::= { media5 2 }
media5-page-count OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION
"Number of sheets of media 5 that have been printed. See
MEDIA1-PAGE-COUNT for details.
Additional information:
See MEDIA1-PAGE-COUNT."
::= { media5 3 }
media5-engine-media-mode OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS optional
DESCRIPTION
"The engine processing characteristics that are to be applied to
this media. The processing characteristics are device
specific.
Additional information:
See the description for MEDIA1-ENGINE-MEDIA-MODE."
::= { media5 4 }
media6-name OBJECT-TYPE
SYNTAX DisplayString (SIZE(1..24))
ACCESS read-only
STATUS optional
DESCRIPTION
"Media 6 name.
Additional information:
See MEDIA1-NAME."
::= { media6 1 }
media6-short-name OBJECT-TYPE
SYNTAX DisplayString (SIZE(1..9))
ACCESS read-only
STATUS optional
DESCRIPTION
"Length restricted version of the media name 6. See
MEDIA1-SHORT-NAME for details.
Additional information:
See MEDIA1-SHORT-NAME."
::= { media6 2 }
media6-page-count OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION
"Number of sheets of media 6 that have been printed. See
MEDIA1-PAGE-COUNT for details.
Additional information:
See MEDIA1-PAGE-COUNT."
::= { media6 3 }
media6-engine-media-mode OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS optional
DESCRIPTION
"The engine processing characteristics that are to be applied to
this media. The processing characteristics are device
specific.
Additional information:
See the description for MEDIA1-ENGINE-MEDIA-MODE."
::= { media6 4 }
media7-name OBJECT-TYPE
SYNTAX DisplayString (SIZE(1..24))
ACCESS read-only
STATUS optional
DESCRIPTION
"Media 7 name.
Additional information:
See MEDIA1-NAME."
::= { media7 1 }
media7-short-name OBJECT-TYPE
SYNTAX DisplayString (SIZE(1..9))
ACCESS read-only
STATUS optional
DESCRIPTION
"Length restricted version of the media name 7. See
MEDIA1-SHORT-NAME for details.
Additional information:
See MEDIA1-SHORT-NAME."
::= { media7 2 }
media7-page-count OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION
"Number of sheets of media 7 that have been printed. See
MEDIA1-PAGE-COUNT for details.
Additional information:
See MEDIA1-PAGE-COUNT."
::= { media7 3 }
media7-engine-media-mode OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS optional
DESCRIPTION
"The engine processing characteristics that are to be applied to
this media. The processing characteristics are device
specific.
Additional information:
See the description for MEDIA1-ENGINE-MEDIA-MODE."
::= { media7 4 }
media8-name OBJECT-TYPE
SYNTAX DisplayString (SIZE(1..24))
ACCESS read-only
STATUS optional
DESCRIPTION
"Media 8 name.
Additional information:
See MEDIA1-NAME."
::= { media8 1 }
media8-short-name OBJECT-TYPE
SYNTAX DisplayString (SIZE(1..9))
ACCESS read-only
STATUS optional
DESCRIPTION
"Length restricted version of the media name 8. See
MEDIA1-SHORT-NAME for details.
Additional information:
See MEDIA1-SHORT-NAME."
::= { media8 2 }
media8-page-count OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION
"Number of sheets of media 8 that have been printed. See
MEDIA1-PAGE-COUNT for details.
Additional information:
See MEDIA1-PAGE-COUNT."
::= { media8 3 }
media8-engine-media-mode OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS optional
DESCRIPTION
"The engine processing characteristics that are to be applied to
this media. The processing characteristics are device
specific.
Additional information:
See the description for MEDIA1-ENGINE-MEDIA-MODE."
::= { media8 4 }
media9-name OBJECT-TYPE
SYNTAX DisplayString (SIZE(1..24))
ACCESS read-only
STATUS optional
DESCRIPTION
"Media 9 name.
Additional information:
See MEDIA1-NAME."
::= { media9 1 }
media9-short-name OBJECT-TYPE
SYNTAX DisplayString (SIZE(1..9))
ACCESS read-only
STATUS optional
DESCRIPTION
"Length restricted version of the media name 9. See
MEDIA1-SHORT-NAME for details.
Additional information:
See MEDIA1-SHORT-NAME."
::= { media9 2 }
media9-page-count OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION
"Number of sheets of media 9 that have been printed. See
MEDIA1-PAGE-COUNT for details.
Additional information:
See MEDIA1-PAGE-COUNT."
::= { media9 3 }
media9-engine-media-mode OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS optional
DESCRIPTION
"The engine processing characteristics that are to be applied to
this media. The processing characteristics are device
specific.
Additional information:
See the description for MEDIA1-ENGINE-MEDIA-MODE."
::= { media9 4 }
media10-name OBJECT-TYPE
SYNTAX DisplayString (SIZE(1..24))
ACCESS read-only
STATUS optional
DESCRIPTION
"Media 10 name.
Additional information:
See MEDIA1-NAME."
::= { media10 1 }
media10-short-name OBJECT-TYPE
SYNTAX DisplayString (SIZE(1..9))
ACCESS read-only
STATUS optional
DESCRIPTION
"Length restricted version of the media name 10. See
MEDIA1-SHORT-NAME for details.
Additional information:
See MEDIA1-SHORT-NAME."
::= { media10 2 }
media10-page-count OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION
"Number of sheets of media 10 that have been printed. See
MEDIA1-PAGE-COUNT for details.
Additional information:
See MEDIA1-PAGE-COUNT."
::= { media10 3 }
media10-engine-media-mode OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS optional
DESCRIPTION
"The engine processing characteristics that are to be applied to
this media. The processing characteristics are device
specific.
Additional information:
See the description for MEDIA1-ENGINE-MEDIA-MODE."
::= { media10 4 }
media11-name OBJECT-TYPE
SYNTAX DisplayString (SIZE(1..24))
ACCESS read-only
STATUS optional
DESCRIPTION
"Media 11 name.
Additional information:
See MEDIA1-NAME."
::= { media11 1 }
media11-short-name OBJECT-TYPE
SYNTAX DisplayString (SIZE(1..9))
ACCESS read-only
STATUS optional
DESCRIPTION
"Length restricted version of the media name 11. See
MEDIA1-SHORT-NAME for details.
Additional information:
See MEDIA1-SHORT-NAME."
::= { media11 2 }
media11-page-count OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION
"Number of sheets of media 11 that have been printed. See
MEDIA1-PAGE-COUNT for details.
Additional information:
See MEDIA1-PAGE-COUNT."
::= { media11 3 }
media11-engine-media-mode OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS optional
DESCRIPTION
"The engine processing characteristics that are to be applied to
this media. The processing characteristics are device
specific.
Additional information:
See the description for MEDIA1-ENGINE-MEDIA-MODE."
::= { media11 4 }
media15-name OBJECT-TYPE
SYNTAX DisplayString (SIZE(1..24))
ACCESS read-write
STATUS optional
DESCRIPTION
"Media 15 name.
Additional information:
The maximum supported string length is 24
bytes. If the user entered string is too long,
the device will store the first 24 bytes and
return the <noError> status.
See CAUTION statement under Product Specific Use."
::= { media15 1 }
media15-short-name OBJECT-TYPE
SYNTAX DisplayString (SIZE(1..9))
ACCESS read-write
STATUS optional
DESCRIPTION
"Length restricted version of the media name 15. See
MEDIA1-SHORT-NAME for details.
Additional information:
The maximum supported string length is 9 characters. If
the user entered string is too long, the device will store
the first 9 characters and will return the
<noError> status.
The characters must be in the range 20H to 7FH except 5C
cannot be used. The default symbol set is Roman-8 for
English; additional legal symbol sets are ISOLatin5,
ISOLatin2 and Windows31J. Setting this object with characters
outside of the range or of an illegal symbol set will cause an
error status of <badValue> to be returned."
::= { media15 2 }
media15-page-count OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION
"Number of sheets of media 15 that have been printed. See
MEDIA1-PAGE-COUNT for details.
Additional information:
See MEDIA1-PAGE-COUNT."
::= { media15 3 }
media15-engine-media-mode OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS optional
DESCRIPTION
"The engine processing characteristics that are to be applied to
this media. The processing characteristics are device
specific.
Additional information:
See the description for MEDIA1-ENGINE-MEDIA-MODE."
::= { media15 4 }
media16-name OBJECT-TYPE
SYNTAX DisplayString (SIZE(1..24))
ACCESS read-write
STATUS optional
DESCRIPTION
"Media 16 name.
Additional information:
See MEDIA15-NAME."
::= { media16 1 }
media16-short-name OBJECT-TYPE
SYNTAX DisplayString (SIZE(1..9))
ACCESS read-write
STATUS optional
DESCRIPTION
"Length restricted version of the media name 16. See
MEDIA1-SHORT-NAME for details.
Additional information:
See MEDIA15-SHORT-NAME."
::= { media16 2 }
media16-page-count OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION
"Number of sheets of media 16 that have been printed. See
MEDIA1-PAGE-COUNT for details.
Additional information:
See MEDIA15-PAGE-COUNT."
::= { media16 3 }
media16-engine-media-mode OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS optional
DESCRIPTION
"The engine processing characteristics that are to be applied to
this media. The processing characteristics are device
specific.
Additional information:
See the description for MEDIA1-ENGINE-MEDIA-MODE."
::= { media16 4 }
media17-name OBJECT-TYPE
SYNTAX DisplayString (SIZE(1..24))
ACCESS read-write
STATUS optional
DESCRIPTION
"Media 17 name.
Additional information:
See MEDIA15-NAME."
::= { media17 1 }
media17-short-name OBJECT-TYPE
SYNTAX DisplayString (SIZE(1..9))
ACCESS read-write
STATUS optional
DESCRIPTION
"Length restricted version of the media name 17. See
MEDIA1-SHORT-NAME for details.
Additional information:
See MEDIA15-SHORT-NAME."
::= { media17 2 }
media17-page-count OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION
"Number of sheets of media 17 that have been printed. See
MEDIA1-PAGE-COUNT for details.
Additional information:
See MEDIA15-PAGE-COUNT."
::= { media17 3 }
media17-engine-media-mode OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS optional
DESCRIPTION
"The engine processing characteristics that are to be applied to
this media. The processing characteristics are device
specific.
Additional information:
See the description for MEDIA1-ENGINE-MEDIA-MODE."
::= { media17 4 }
media18-name OBJECT-TYPE
SYNTAX DisplayString (SIZE(1..24))
ACCESS read-write
STATUS optional
DESCRIPTION
"Media 18 name.
Additional information:
See MEDIA15-NAME."
::= { media18 1 }
media18-short-name OBJECT-TYPE
SYNTAX DisplayString (SIZE(1..9))
ACCESS read-write
STATUS optional
DESCRIPTION
"Length restricted version of the media name 18. See
MEDIA1-SHORT-NAME for details.
Additional information:
See MEDIA15-SHORT-NAME."
::= { media18 2 }
media18-page-count OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION
"Number of sheets of media 18 that have been printed. See
MEDIA1-PAGE-COUNT for details.
Additional information:
See MEDIA15-PAGE-COUNT."
::= { media18 3 }
media18-engine-media-mode OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS optional
DESCRIPTION
"The engine processing characteristics that are to be applied to
this media. The processing characteristics are device
specific.
Additional information:
See the description for MEDIA1-ENGINE-MEDIA-MODE."
::= { media18 4 }
media19-name OBJECT-TYPE
SYNTAX DisplayString (SIZE(1..24))
ACCESS read-write
STATUS optional
DESCRIPTION
"Media 19 name.
Additional information:
See MEDIA15-NAME."
::= { media19 1 }
media19-short-name OBJECT-TYPE
SYNTAX DisplayString (SIZE(1..9))
ACCESS read-write
STATUS optional
DESCRIPTION
"Length restricted version of the media name 19. See
MEDIA1-SHORT-NAME for details.
Additional information:
See MEDIA15-SHORT-NAME."
::= { media19 2 }
media19-page-count OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION
"Number of sheets of media 19 that have been printed. See
MEDIA1-PAGE-COUNT for details.
Additional information:
See MEDIA15-PAGE-COUNT."
::= { media19 3 }
media19-engine-media-mode OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS optional
DESCRIPTION
"The engine processing characteristics that are to be applied to
this media. The processing characteristics are device
specific.
Additional information:
See the description for MEDIA1-ENGINE-MEDIA-MODE."
::= { media19 4 }
media21-name OBJECT-TYPE
SYNTAX DisplayString (SIZE(1..24))
ACCESS read-only
STATUS optional
DESCRIPTION
"Media 21 name.
Additional information:
See MEDIA1-NAME."
::= { media21 1 }
media21-short-name OBJECT-TYPE
SYNTAX DisplayString (SIZE(1..9))
ACCESS read-only
STATUS optional
DESCRIPTION
"Length restricted version of the media name 21. See
MEDIA1-SHORT-NAME for details.
Additional information:
See MEDIA1-SHORT-NAME."
::= { media21 2 }
media21-page-count OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION
"Number of sheets of media 21 that have been printed. See
MEDIA1-PAGE-COUNT for details.
Additional information:
See MEDIA1-PAGE-COUNT."
::= { media21 3 }
media21-engine-media-mode OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS optional
DESCRIPTION
"The engine processing characteristics that are to be applied to
this media. The processing characteristics are device
specific.
Additional information:
See the description for MEDIA1-ENGINE-MEDIA-MODE."
::= { media21 4 }
media32-name OBJECT-TYPE
SYNTAX DisplayString (SIZE(1..24))
ACCESS read-only
STATUS optional
DESCRIPTION
"Media 32 name.
Additional information:
See MEDIA1-NAME."
::= { media32 1 }
media32-short-name OBJECT-TYPE
SYNTAX DisplayString (SIZE(1..9))
ACCESS read-only
STATUS optional
DESCRIPTION
"Length restricted version of the media name 32. See
MEDIA1-SHORT-NAME for details.
Additional information:
See MEDIA1-SHORT-NAME."
::= { media32 2 }
media32-page-count OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION
"Number of sheets of media 32 that have been printed. See
MEDIA1-PAGE-COUNT for details.
Additional information:
See MEDIA1-PAGE-COUNT."
::= { media32 3 }
media32-engine-media-mode OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS optional
DESCRIPTION
"The engine processing characteristics that are to be applied to
this media. The processing characteristics are device
specific.
Additional information:
See the description for MEDIA1-ENGINE-MEDIA-MODE."
::= { media32 4 }
engine-media-modes-supported1 OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS optional
DESCRIPTION
"The list of engine media modes supported by the device. The
modes are each separated by a comma character. An example
string would be: 'Normal,Rough,Low,Vellum'."
::= { media-modes 1 }
media-size-west-edge-first-side-offset OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS optional
DESCRIPTION
"Returns or sets the number of 300 dpi dots by which the image
is shifted relative to the west edge of the medium (see
NORTH-EDGE-OFFSET). The adjustment is for the first printed
side of the medium only. A positive value moves the image away
from the west edge of the medium. A negative value moves the
image closer to the west edge of the medium. The value 0 will
return the image to its factory default position.
Additional information:
Returns or sets the number of 300 dpi dots by which the
image is shifted relative to the west edge of the medium
(see NORTH-EDGE-OFFSET). The adjustment is for the
first printed side of the medium only. A positive value
moves the image away from the west edge of the medium.
A negative value moves the image closer to the west edge
of the medium. The value 0 will return the image to its
factory default position. The values in the sub array index
are from the media size table in the hpmib. This adjustment is done
on a paper size by paper size basis. The standard PCL5 codes for
paper size are used for the value used in the OID. Please see
S_ARRAY_SUB1 for legal values. The data for this object is stored
in NVRAM."
::= { media-size 2 }
media-size-west-edge-second-side-offset OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS optional
DESCRIPTION
"Returns or sets the number of 300 dpi dots by which the image
is shifted relative to the west edge of the medium (see
NORTH-EDGE-OFFSET). The adjustment is for the second printed
side of the medium only. A positive value moves the image away
from the west edge of the medium. A negative value moves the
image closer to the west edge of the medium. The value 0 will
return the image to its factory default position.
Additional information:
Returns or sets the number of 300 dpi dots by which the
image is shifted relative to the west edge of the medium
(see NORTH-EDGE-OFFSET). The adjustment is for the
second printed side of the medium only. A positive value
moves the image away from the west edge of the medium.
A negative value moves the image closer to the west edge
of the medium. The value 0 will return the image to its
factory default position. The values in the sub array index
are from the media size table in the hpmib.
This adjustment is done on a paper size by paper size basis.
The standard PCL5 codes for paper size are used for the value
used in the OID. Please see S_ARRAY_SUB1 for legal values.
The data for this object is stored in NVRAM."
::= { media-size 3 }
media-size-west-edge-side-offset-by-tray OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS optional
DESCRIPTION
"Returns or sets the number of 300 dpi dots by which the image
is shifted relative to the west edge of the medium (see
NORTH-EDGE-OFFSET). A positive value moves the image away from
the west edge of the medium. A negative value moves the image
closer to the west edge of the medium. The value 0 will return
the image to its factory default position. Each OID binding
corresponds to a valid tray number for this product. There can
be a maximum of 15 trays, a combination of internal and
external trays. Products that support other combinations of
trays will specify this information in the device pos. The data
for this object is stored in NVRAM.
Additional information:
Returns or sets the number of 300 dpi dots by which the
image is shifted relative to the west edge of the medium
(see NORTH-EDGE-OFFSET). A positive value moves the
image away from the west edge of the medium. A negative
value moves the image closer to the west edge of the medium.
The value 0 will return the image to its factory default
position.
Each OID binding corresponds to a valid tray number
for this product. There can be a maximum of 15 trays, a
combination of internal and external trays. Products that
support other combinations of trays will specify this
information in the device pos. The data for this object
is stored in NVRAM."
::= { media-size 4 }
printed-media-simplex-count OBJECT-TYPE
SYNTAX INTEGER(0..930576247)
ACCESS read-only
STATUS optional
DESCRIPTION
"Total number of simplex pages printed in this media size.
Additional information:
The 5 usage (simplex/duplex count, simplex/duplex click
charge and paper size total) objects described here and
below detail the usage for the printer for each paper
size defined in the PCL Implementor's Guide and in the
Media Size Table in the hpmib.txt. The OID binding is
based on the click attribute and paper size.
For example:
The format for the OID is as follows:
3.4.1.5.x.y
<-----> | |
| | \
/ | paper size
/ \
PRINTER-CLICK_TOTALS ROOT \
OID click attribute 1..5
x values are 1..5:
1) simplex count
2) simplex click charge
3) duplex count
4) duplex click charge
5) printer or scanner paper size total (i.e. depends if the
root OID is referrring to the printer or scanner).
y : paper size as defined in the Media Size Table in the
hpmib.txt "
::= { printed-media-usage 1 }
printed-media-simplex-charge OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS optional
DESCRIPTION
"Charge for each simplex page printed in this media size."
::= { printed-media-usage 2 }
printed-media-duplex-count OBJECT-TYPE
SYNTAX INTEGER(0..930576247)
ACCESS read-only
STATUS optional
DESCRIPTION
"Total number of duplex pages printed in this media size."
::= { printed-media-usage 3 }
printed-media-duplex-charge OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS optional
DESCRIPTION
"Charge for each duplex page printed in this media size.
Additional information:
The click charges for duplex printed media."
::= { printed-media-usage 4 }
printed-media-total-charge OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-only
STATUS optional
DESCRIPTION
"The total charge for pages printed in this media size."
::= { printed-media-usage 5 }
printed-media-maximum-pixels-per-page OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION
"The number of pixels required to completely fill a page of this
media size. The device POS will specify the resolution at which
this pixel count was calculated.
Additional information:
The number of pixels required to fill a page of a
specific media size. The OID binding is the media
size you to query for. Only media sizes which the
printer supports will be available. These numbers
are based on full sized pages and 1200 dpi in both
the x and y directions. For example the letter
calculation is 8.5 x 1200 x 11 x 1200."
::= { printed-media-usage 6 }
usage-printer-total-charge OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-only
STATUS optional
DESCRIPTION
"Total printer charge for all paper sizes printed."
::= { printer-accounting 2 }
usage-average-toner-coverage OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-only
STATUS optional
DESCRIPTION
"Reports the average toner area coverage of all pages printed
over the life of the device. Counts pixels on each page,
divides pixel count by pixels possible on a page to give the
percentage of coverage, and keeps a rolling average percent
weighted by area printed."
::= { printer-accounting 3 }
usage-staple-count OBJECT-TYPE
SYNTAX INTEGER(0..930576247)
ACCESS read-only
STATUS optional
DESCRIPTION
"Total number of staples used."
::= { printer-accounting 4 }
usage-instructions-line1 OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..40))
ACCESS read-write
STATUS optional
DESCRIPTION
"The first line of usage instructions for the device
user.Appears on Line 1 of the usage page."
::= { printer-accounting 5 }
usage-instructions-line2 OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..40))
ACCESS read-write
STATUS optional
DESCRIPTION
"The second line of usage instructions for the device
user.Appears on Line 1 of the usage page."
::= { printer-accounting 6 }
usage-instructions-line3 OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..40))
ACCESS read-write
STATUS optional
DESCRIPTION
"The third line of usage instructions for the device
user.Appears on Line 1 of the usage page."
::= { printer-accounting 7 }
usage-instructions-line4 OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..40))
ACCESS read-write
STATUS optional
DESCRIPTION
"The fourth line of usage instructions for the device
user.Appears on Line 1 of the usage page."
::= { printer-accounting 8 }
low-marking-agent-processing OBJECT-TYPE
SYNTAX INTEGER {
eStop(1),
eCont(2)
}
ACCESS read-write
STATUS optional
DESCRIPTION
"Returns or changes how the device processes a low marking agent
event. If eCont, then the device continues to print. If eStop,
then the device stops until a continue event occurs."
::= { settings-marking-agent 3 }
out-marking-agent-processing OBJECT-TYPE
SYNTAX INTEGER {
eStop(1),
eCont(2)
}
ACCESS read-write
STATUS optional
DESCRIPTION
"Returns or changes how the device processes an out marking
agent event. If eCont, then the device continues to print. If
eStop, then the device stops until a continue event occurs."
::= { settings-marking-agent 10 }
media-size-count OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION
"The number of impressions printed on sheets of this media size.
The device POS should state whether this value is lost across a
power cycle or is kept in permanent storage.
Additional information:
The value of this object is persistent across a power cycle.
The index for these objects, the last number of the OID, uniquely
identifies the paper size. This value corresponds to the page sizes listed below.
These values are also documented in the PCL Implementor's Guide
and the PML Master MIB.
1 US-Executive
2 US-Letter
3 US-Legal
10 Foolscap
11 eLedger
17 ROC 16K
18 JIS Executive
19 eROC8K
25 ISO and JIS A5
26 ISO and JIS A4
27 ISO and JIS A3
45 JIS B5
46 JIS B4
65 ISO B5
72 eJapanesePostcardDouble
80 Monarch
81 Commercal-10
90 International DL
91 International C5
100 International B5
101 Custom
258 eUSLetterR
282 ISO JISA4R
32767 Unknown Paper Size"
::= { media-size 1 }
consumable-status-cartridge-model OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..24))
ACCESS read-only
STATUS optional
DESCRIPTION
"This object is used to read the cartridge model number
associated with this consumable.
Additional information:
This object will only exist for Authentic HP consumables.
If the cartridge is deemed to be NonHP, then this object
will not exist."
::= { consumable-status 1 }
consumable-status-manufacturing-date OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..24))
ACCESS read-only
STATUS optional
DESCRIPTION
"This object is used to report the date on which this consumable
was manufactured. The format of the string is 'YYYYMMDD', where
YYYY is the year, MM is the month (1-12), and DD is the day
(1-31).
Additional information:
This object will only exist for Authentic HP consumables.
If the cartridge is deemed to be NonHP, then this object
will not exist."
::= { consumable-status 2 }
consumable-status-serial-number OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..24))
ACCESS read-only
STATUS optional
DESCRIPTION
"This object is used to report the serial number for this
consumable.
Additional information:
This object will only exist for Authentic HP consumables.
If the cartridge is deemed to be NonHP, then this object
will not exist."
::= { consumable-status 3 }
consumable-status-capacity-units OBJECT-TYPE
SYNTAX INTEGER {
ePagesAt5PercentCoverage(1),
e1KPagesAt5PercentCoverage(2),
e10KPagesAt5PercentCoverage(3)
}
ACCESS read-only
STATUS optional
DESCRIPTION
"This object is used to report the usage units used by the
CONSUMABLE-STATUS-TOTAL-CAPACITY object.
Additional information:
This object will only exist on engines that are E-Label
capable, but will exist on these engines regardless of
the cartridge being Authentic HP or NonHP. This object
can be used to ensure the capability of the E-Label
feature for a given engine."
::= { consumable-status 4 }
consumable-status-total-capacity OBJECT-TYPE
SYNTAX INTEGER(0..65535)
ACCESS read-only
STATUS optional
DESCRIPTION
"This object is used to report the total capacity of a new
consumable of this type. The PML object
CONSUMABLE-STATUS-CAPACITY-UNITS can be used to determine the
units of measure for this PML object.
Additional information:
This object will only exist for Authentic HP consumables.
If the cartridge is deemed to be NonHP, then this object
will not exist."
::= { consumable-status 5 }
consumable-status-reseller-id OBJECT-TYPE
SYNTAX INTEGER(0..2147483647)
ACCESS read-write
STATUS optional
DESCRIPTION
"This object is used to query and set the reseller ID for this
consumable. This ID is represented as an integer that is
essentially an enumeration representing a specific reseller
that sells this consumable. The device POS should detail the
mapping of reseller name to reseller ID. In this way the
reseller can program into the consumable a suggested reseller
which can in turn be mapped to a web page through which a
replacement can be purchased.
Additional information:
This object will only exist for Authentic HP consumables.
If the cartridge is deemed to be NonHP, then this object
will not exist. The reseller ID is an integer that must
be mapped external to the printer by a host application.
The value stored must be specific to an external application."
::= { consumable-status 6 }
consumable-status-info OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS optional
DESCRIPTION
"This object is used to read and write the various status flags
supported by this consumable. For LaserJet 4100, LaserJet 4550 the collection
bits supported include:
cMarkedAsReordered - indicates the consumable has been
reordered. This is the only bit that can be both read
and written.
cTonerLowCondition - indicates a toner low condition has
occured. This bit in the collection is read-only to
PML.
cTonerOutCondition - indicates a toner out condition has
occured. This bit in the collection is read-only to
PML.
cDeveloperLowCondition - indicates a developer low
condition has occured. This bit in the collection is
read-only to PML.
cDeveloperOutCondition - indicates a developer out
condition has occured. This bit in the collection is
read-only to PML.
cDrumLowCondition - indicates a drum low condition has
occured. This bit in the collection is read-only to
PML.
cDrumOutCondition - indicates a drum out condition has
occured. This bit in the collection is read-only to
PML.
cWasteTonerFullCondition - indicates a waste toner full
condition has occured. This bit in the collection is
read-only to PML.
cWasteTonerFullWarningCondition - indicates a waste toner
full warning condition has occured. This bit in the
collection is read-only to PML.
cNewConsumable - indicates the consumable is new and has
never been used. This bit in the collection is
read-only to PML.
cTonerLowNotificationSent - inidicates that toner low
notification has been sent for this consumable. This
bit in the collection is readonly.
cTonerOutNotificationSent - inidicates that toner out
notification has been sent for this consumable. This
bit in the collection is read only.
cAnyPartLowCondition - indicates that at least one part of
this consumable has reached a low condition. This bit
in the collection is read-only to PML.
cAnyPartOutCondition - indicates that at least one part of
this consumable has reached an out condition. This bit
in the collection is read-only to PML.
Additional information:
This object will only exist for Authentic HP consumables.
If the cartridge is deemed to be NonHP, then this object
will not exist."
::= { consumable-status 7 }
consumable-status-first-install-date OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..24))
ACCESS read-only
STATUS optional
DESCRIPTION
"This object is used to report the date on which this consumable
was first installed. The format of the string is 'YYYYMMDD'.
Where:
YYYY is the year.
MM is the month (1-12).
DD is the day (1-31).
The device POS needs to indicate what will be written in the
event the printer does not have a real time clock.
Additional information:
This object will only exist for Authentic HP consumables.
If the cartridge is deemed to be NonHP, then this object
will not exist. For printers without internal clocks, the
date will always be 20000101."
::= { consumable-status 8 }
consumable-status-last-use-date OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..24))
ACCESS read-only
STATUS optional
DESCRIPTION
"This object is used to report the date on which this consumable
was last used. The format of the string is 'YYYYMMDD'. Where:
YYYY is the year.
MM is the month (1-12).
DD is the day (1-31).
The device POS needs to indicate what will be written in the
event the printer does not have a real time clock.
Additional information:
This object will only exist for Authentic HP consumables.
If the cartridge is deemed to be NonHP, then this object
will not exist. For printers without internal clocks, the
date will always be 20000101."
::= { consumable-status 9 }
consumable-status-page-count-legal OBJECT-TYPE
SYNTAX INTEGER(0..65535)
ACCESS read-only
STATUS optional
DESCRIPTION
"This object is used to report the number of pages that have
been printed by this consumable that are of the specified media
size - Legal.
Additional information:
This object will only exist for Authentic HP consumables.
If the cartridge is deemed to be NonHP, then this object
will not exist."
::= { consumable-status 11 }
consumable-status-page-count-a4-letter OBJECT-TYPE
SYNTAX INTEGER(0..65535)
ACCESS read-only
STATUS optional
DESCRIPTION
"This object is used to report the number of pages that have
been printed by this consumable that are of the specified media
size - A4 or Letter.
Additional information:
This object will only exist for Authentic HP consumables.
If the cartridge is deemed to be NonHP, then this object
will not exist."
::= { consumable-status 12 }
consumable-status-page-count-b5-executive OBJECT-TYPE
SYNTAX INTEGER(0..65535)
ACCESS read-only
STATUS optional
DESCRIPTION
"This object is used to report the number of pages that have
been printed by this consumable that are of the specified media
size - B5 or Executive.
Additional information:
This object will only exist for Authentic HP consumables.
If the cartridge is deemed to be NonHP, then this object
will not exist."
::= { consumable-status 13 }
consumable-status-page-count-xy-other OBJECT-TYPE
SYNTAX INTEGER(0..65535)
ACCESS read-only
STATUS optional
DESCRIPTION
"This object is used to report the number of pages that have
been printed by this consumable that are of the specified media
size - XY or Other.
Additional information:
This object will only exist for Authentic HP consumables.
If the cartridge is deemed to be NonHP, then this object
will not exist."
::= { consumable-status 15 }
consumable-status-job-count OBJECT-TYPE
SYNTAX INTEGER(0..65535)
ACCESS read-only
STATUS optional
DESCRIPTION
"This object is used to report the number of jobs that have been
printed by this consumable.
Additional information:
This object will only exist for Authentic HP consumables.
If the cartridge is deemed to be NonHP, then this object
will not exist."
::= { consumable-status 16 }
consumable-status-usage-units OBJECT-TYPE
SYNTAX INTEGER {
ePixels(1),
eTenthsOfGrams(2),
eGrams(3),
eRotations(4),
ePages(5),
eImpressions(6),
ePercentLifeRemaining(7),
eOther(8)
}
ACCESS read-only
STATUS optional
DESCRIPTION
"This object is used to report the units used to measure the
capacity of this consumable.
Additional information:
This object will only exist on engines that are E-Label
capable, but will exist on these engines regardless of
the cartridge being Authentic HP or NonHP. This object
can be used to ensure the capability of the E-Label
feature for a given engine."
::= { consumable-status 17 }
consumable-status-usage-count OBJECT-TYPE
SYNTAX INTEGER(0..65535)
ACCESS read-only
STATUS optional
DESCRIPTION
"This object is used to report the number of usage units that
remain in this consumable. The units of measurement used by
this object can be obtained by querying the
CONSUMABLE-STATUS-USAGE-UNITS object.
Additional information:
This object will only exist for Authentic HP consumables.
If the cartridge is deemed to be NonHP, then this object
will not exist."
::= { consumable-status 18 }
consumable-status-manufacturer-name OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..8))
ACCESS read-only
STATUS optional
DESCRIPTION
"This object is used to report the name of the manufacturer of
this consumable. The device POS will specify the set of
manufacturers that could be returned.
Additional information:
This object will only exist for Authentic HP consumables.
If the cartridge is deemed to be NonHP, then this object
will not exist."
::= { consumable-status 19 }
consumable-status-oem-name OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..8))
ACCESS read-only
STATUS optional
DESCRIPTION
"This object is used to report the name of the OEM of this
consumable. This object will typically return the string 'HP'.
The device POS will specify if other OEM consumables are
supported.
Additional information:
This object will only exist for Authentic HP consumables.
If the cartridge is deemed to be NonHP, then this object
will not exist. This object should always return 'HP' as
the OEM name"
::= { consumable-status 20 }
consumable-status-engine-usage-units OBJECT-TYPE
SYNTAX INTEGER {
ePixels(1),
eTenthsOfGrams(2),
eGrams(3),
eRotations(4),
ePages(5),
eImpressions(6),
ePercentLifeRemaining(7),
eOther(8)
}
ACCESS read-only
STATUS optional
DESCRIPTION
"This object is used to report the units used to measure the
capacity of this consumable as reported by the Engine.
Additional information:
This object will only exist on engines that are E-Label
capable, but will exist on these engines regardless of
the cartridge being Authentic HP or NonHP. This object
can be used to ensure the capability of the E-Label
feature for a given engine."
::= { consumable-status 21 }
consumable-status-engine-usage-count OBJECT-TYPE
SYNTAX INTEGER(0..65535)
ACCESS read-only
STATUS optional
DESCRIPTION
"This object is used to report the number of usage units,
estimated by the engine, that remain in this consumable. The
units of measurement used by this object can be obtained by
querying the CONSUMABLE-STATUS-ENGINE-USAGE-UNITS object.
Additional information:
This object will only exist for Authentic HP consumables.
If the cartridge is deemed to be NonHP, then this object
will not exist."
::= { consumable-status 22 }
consumable-status-engine-job-count OBJECT-TYPE
SYNTAX INTEGER(0..65535)
ACCESS read-only
STATUS optional
DESCRIPTION
"This object is used to report the number of jobs, as reported
by the printer, that have been printed by this consumable.
Additional information:
This object will only exist for Authentic HP consumables.
If the cartridge is deemed to be NonHP, then this object
will not exist."
::= { consumable-status 23 }
consumable-status-drum-life-units OBJECT-TYPE
SYNTAX INTEGER {
ePixels(1),
eTenthsOfGrams(2),
eGrams(3),
eRotations(4),
ePages(5),
eImpressions(6),
ePercentLifeRemaining(7),
eOther(8)
}
ACCESS read-only
STATUS optional
DESCRIPTION
"This object is used to report the units used to measure the
drum life remaining.
Additional information:
This object will only exist on engines that are E-Label
capable, but will exist on these engines regardless of
the cartridge being Authentic HP or NonHP. This object
can be used to ensure the capability of the E-Label
feature for a given engine."
::= { consumable-status 38 }
consumable-status-drum-life OBJECT-TYPE
SYNTAX INTEGER(0..65535)
ACCESS read-only
STATUS optional
DESCRIPTION
"This object is used to report the number of life units,
remaining in the drum. The units of measurement used by this
object can be obtained by querying the CONSUMABLE-
STATUS-DRUM-LIFE-UNITS object. This object will not exist if
this consumable does not contain a drum.
Additional information:
This object will only exist on engines that are E-Label
capable, but will exist on these engines regardless of
the cartridge being Authentic HP or NonHP. This object
can be used to ensure the capability of the E-Label
feature for a given engine."
::= { consumable-status 39 }
consumable-reorder-url OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..64))
ACCESS read-write
STATUS optional
DESCRIPTION
"This object is used to read and write the URL that can be used
to reorder consumables for this device. This URL is set at the
factory but can be updated by a reseller or third party.
Additional information:
The URL can be up to 64 characters long."
::= { consumables 2 }
consumable-life-usage-units-remaining OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION
"This object reports the current estimate of the number of usage
units that remain before this supply is depleted. An installed
supply that cannot report such a number will return a value of
-2. It is the reponsibility of the host application to query
each supply in order to determine an overall device
USAGE-UNITS-REMAINING number - the lowest value returned. The
unit of measure for this life estimate is determined by reading
the corresponding CONSUMABLE-LIFE-USAGE-UNITS object.
Additional information:
This object returns the Estimated Number of Pages
Remaining for the specified supply. It takes
into account both the Toner and the Drum contained
within the cartride and reports the lower of the
two values."
::= { consumables-life 1 }
consumable-life-usage-units OBJECT-TYPE
SYNTAX INTEGER {
ePagesRemaining(1),
eEstimatedPagesRemaining(2),
eUnknownUnits(3),
ePagesSinceLow(4),
ePagesSinceOut(5)
}
ACCESS read-only
STATUS optional
DESCRIPTION
"This object reports current usage units in use by the
corresponding CONSUMABLE-LIFE-USAGE-UNITS-REMAINING object.
Additional information:
This object always responds with eEstimatedPagesRemaining
for the the Black Toner cartridge."
::= { consumables-life 2 }
printer-average-marking-agent-coverage OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-only
STATUS optional
DESCRIPTION
"This object is used to read the average marking agent coverage
for a given color plane. It is a real number that represents
percentage full and will read from 0 to 100%. This object
obsoletes or replaces USAGE-AVERAGE-TONER-COVERAGE which could
only be used for black toner coverage information.
Additional information:
The average percent of toner coverage for a specific
color plane. The OID binding is the color plane.
Only color planes which the printer supports will be
available. This is only available if a hard disk is
installed."
::= { printer-average 1 }
printer-average-marking-agent-coverage-sum OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-only
STATUS optional
DESCRIPTION
"This object is used to read the accumulated sum of the percent
coverage numbers calculated on a per page basis over the life
of the printer.
Additional information:
The sum of the percent toner coverages for all
impressions printed. The OID binding is the color
plane. Only color planes which the printer supports
will be available."
::= { printer-average 2 }
printer-average-marking-agent-coverage-sum-squared OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-only
STATUS optional
DESCRIPTION
"This object is used to read the accumulated sum of the squares
of the percent coverage numbers calculated on a per page basis
over the life of the printer.
Additional information:
The sum of the percent toner coverages squared for
all impressions printed. The OID binding is the
color plane. Only color planes which the printer
supports will be available."
::= { printer-average 3 }
printer-average-marking-agent-units-per-gram OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-only
STATUS optional
DESCRIPTION
"This object is used to read the marking agent units of measure
per gram. This is typically a conversion factor for converting
pixels of toner to grams. This pixels-per-gram value is used to
calculate the estimated number of pages remaining for a given
marking agent."
::= { printer-average 4 }
printer-average-marking-agent-coverage-actual OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-only
STATUS optional
DESCRIPTION
"This object is used to read the actual average marking agent
coverage for a given color plane. It is a real number that
represents percent coverage and will read from 0 to 100%. This
object will return the same value as
PRINTER-AVERAGE-MARKING-AGENT-COVERAGE except under certain
conditions which will be specified in the device POS.
Additional information:
This object will return the historical page coverage based on
the specific supply requested. It is not based on the printers
historical value"
::= { printer-average 5 }
web-server-url OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..64))
ACCESS read-write
STATUS optional
DESCRIPTION
"A Universal Resource Locator (URL) from which the Embedded Web
Server can be configured. Any limitation on the size of this
URL will be specified in the device POS."
::= { settings-webserver 2 }
web-server-security OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS optional
DESCRIPTION
"Each collection bit represents a device or Embedded Web Server
feature that can be enabled or disabled via this object."
::= { settings-webserver 3 }
firmware-download-write-status-supported OBJECT-TYPE
SYNTAX INTEGER {
eFalse(1),
eTrue(2)
}
ACCESS read-only
STATUS optional
DESCRIPTION
"This object provides information on whether the printer has the
ability to communicate the write-status of the firmware
download while the download is taking place."
::= { firmware-download 1 }
firmware-download-write-time OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION
"If the design of the firmware-download implementation does not
allow PML interaction during the download process, this value
provides an estimation of the time where the printer will not
be able to engage in PML communication.
Additional information:
If the design of the firmware-download
implementation does not allow PML interaction during
the download process, this value provides an
estimation of the time where the printer will not be
able to engage in PML communication. The calculated
time is expected to be 140 secs. However, this time
may increase as high as 280 secs as the flash part
nears the maximum flash count."
::= { firmware-download 2 }
firmware-download-write-count OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION
"Tells the number of times that firmware has been downloaded to
the flash part.
Additional information:
Tells the number of times that firmware has been
downloaded to the flash part. The default value will
vary depending on how many times the firmware is
rolled before shipping."
::= { firmware-download 3 }
firmware-download-current-state OBJECT-TYPE
SYNTAX INTEGER {
eIdle(1),
eReceivingImage(2),
eReceivedImageError(3),
eVerifyingImage(4),
eVerifiedImageError(5),
eWritingImage(6),
eWritingImageError(7),
eDownloadComplete(8),
eOKtoShutDown(9),
eCancelDownload(10),
eShuttingDown(11)
}
ACCESS read-write
STATUS optional
DESCRIPTION
"Provides the current or last reportable state of the firmware
download process. The current state may not necessarily be the
current state, but could be the post-mortem state."
::= { firmware-download 4 }
firmware-download-maximum-write-count OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION
"Reports the manufacturer specified number of times that
firmware can be downloaded to the flash part. A value of -1
means that there is no limit. A value of 0 means that
downloading firmware is not permitted by this part. Any other
positive integer value corresponds to the number of times that
firmware can be downloaded to the flash part.
Additional information:
Reports the manufacturer specified number of
times that firmware can be downloaded to the flash
part. A value of -1 means that there is no limit.
A value of 0 means that downloading firmware is not
permitted by this part. Any other positive integer
value corresponds to the number of times that
firmware can be downloaded to the flash part. The
current maximum write count is 500. This may change
as flash technology evolves."
::= { firmware-download 5 }
firmware-download-name OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This returns the name of the printer. This should match the
name in the header of the upgrade image being sent to the flash
part. If the name does not match with the name returned then
the image that we are attempting to download does not upgrade
the printer firmware.
Additional information:
This object returns the HP name of the printer.
This should match what is in the PJL header of the RFU job
Web Jet Admin uses this to ensure the printer is available
to be upgraded."
::= { firmware-download 6 }
firmware-download-version OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This object will return a string value representing the current
revision of firmware that the printer is operating with. This
is used to determine if code needs to be upgraded when an
firmware bundle comes in, in an upgrade job.
Additional information:
Web Jet Admin uses the version string that is returned to
determine what peices of an RFU bundle need to be upgraded
when an RFU job is being built. This objects will return
the version string of the printer."
::= { firmware-download 7 }
upgradable-devices-write-status-supported OBJECT-TYPE
SYNTAX INTEGER {
eFalse(1),
eTrue(2)
}
ACCESS read-only
STATUS optional
DESCRIPTION
"This object provides information on whether the upgradable
device has the ability to communicate the write-status of the
upgrade while the upgrade is taking place."
::= { upgradable-devices 1 }
upgradable-devices-write-time OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION
"If the design of the device upgrade implementation does not
allow PML interaction during the download process, this value
provides an estimation of the time where the device will not be
able to engage in PML communication. The time returned will
depend upon what device is attempting to be upgraded."
::= { upgradable-devices 2 }
upgradable-devices-write-count OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION
"Tells the number of times that firmware for device X has been
downloaded to the flash part. The default value will vary
depending on how many times the firmware is rolled before
shipping."
::= { upgradable-devices 3 }
upgradable-devices-current-state OBJECT-TYPE
SYNTAX INTEGER {
eIdle(1),
eReceivedImage(2),
eReceivedImageError(3),
eVerifiedImage(4),
eVerifiedImageError(5),
eWritingImage(6),
eWritingImageError(7),
eUpgradeComplete(8)
}
ACCESS read-only
STATUS optional
DESCRIPTION
"Provides the current or last reportable state of the device
upgrade process. The current state may not necessarily be the
current state, but could be the post-mortem state."
::= { upgradable-devices 4 }
upgradable-devices-max-write-count OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION
"Reports the manufacturer specified number of times that
firmware for device X can be downloaded to the flash part. A
value of -1 means that there is no limit. A value of 0 means
that downloading firmware is not permitted by this part. Any
other positive integer value corresponds to the number of times
that the firmware for device X can be downloaded to the flash
part. The current maximum write count is 500. This may change
as flash technology evolves."
::= { upgradable-devices 5 }
upgradable-devices-name OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This returns the name of the upgradable device. This should
match the name in the header of the upgrade image being sent to
the flash part. If the name does not match with any of the
names returned then the device that we are attempting to
upgrade is unavailable for upgrading.
Additional information:
This object returns the HP name of the printer and the upgradable
devices. There is one Name object per upgradable device.
This should match what is in the PJL header of the RFU job
Web Jet Admin uses this to ensure the printer or device is
available to be upgraded."
::= { upgradable-devices 6 }
upgradable-devices-version OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This object will return a string value representing the current
revision of firmware that device X is operating with. This is
used to determine if code needs to be upgraded when a firmware
bundle comes in, in an upgrade job.
Additional information:
Web Jet Admin uses the version string that is returned to
determine what peices of an RFU bundle need to be upgraded
when an RFU job is being built. This internal object will
return the current version string of the printer or device
that it corresponds to."
::= { upgradable-devices 7 }
remote-upgrade-enable OBJECT-TYPE
SYNTAX INTEGER {
eOff(1),
eOn(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Enables or disables the ability to upgrade the firmware
associated with any device that is available to be upgraded.
This will be set to on or off at the RFU level in that if this
mode is on any available device can be upgraded and if this
mode is off none of the devices can be upgraded. There is not
an individual mode for each device. Trying to set this to a
value other than eOn or eOff will cause an UnsupportedValue
error to occur."
::= { upgradable-devices 8 }
END