-- Copyright (c) 2010-2013 Hewlett-Packard Development Company, L.P.
--
-- Description: This MIB define objects for MPLS Te Tunnel.
-- Reference:
-- Version: V1.0
-- History:
-- V1.0 2011-03-24 Created by fengnina 04924.
-- ==================================================================
HPN-ICF-TE-TUNNEL-MIB DEFINITIONS ::= BEGIN
IMPORTS
hpnicfCommon
FROM HPN-ICF-OID-MIB
MplsTunnelIndex, MplsTunnelInstanceIndex, MplsExtendedTunnelId, MplsLabel
FROM MPLS-TC-STD-MIB
OBJECT-GROUP, MODULE-COMPLIANCE, NOTIFICATION-GROUP
FROM SNMPv2-CONF
Unsigned32, OBJECT-TYPE, MODULE-IDENTITY, NOTIFICATION-TYPE
FROM SNMPv2-SMI
RowPointer
FROM SNMPv2-TC;
hpnicfTeTunnel MODULE-IDENTITY
LAST-UPDATED "201103240948Z" -- March 24, 2011 at 09:48 GMT
ORGANIZATION
""
CONTACT-INFO
""
DESCRIPTION
"This MIB contains managed object definitions for the
Multiprotocol Label Switching (MPLS) Te Tunnel."
::= { hpnicfCommon 115 }
--
-- Node definitions
--
hpnicfTeTunnelScalars OBJECT IDENTIFIER ::= { hpnicfTeTunnel 1 }
hpnicfTeTunnelMaxTunnelIndex OBJECT-TYPE
SYNTAX MplsTunnelIndex
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The max value of tunnel id is permitted configure on the device."
::= { hpnicfTeTunnelScalars 1 }
hpnicfTeTunnelObjects OBJECT IDENTIFIER ::= { hpnicfTeTunnel 2 }
hpnicfTeTunnelStaticCrlspTable OBJECT-TYPE
SYNTAX SEQUENCE OF HpnicfTeTunnelStaticCrlspEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table contains information for static-crlsp, and through this
to get detail information about this static-crlsp. Only support
transit LSR and egress LSR."
::= { hpnicfTeTunnelObjects 1 }
hpnicfTeTunnelStaticCrlspEntry OBJECT-TYPE
SYNTAX HpnicfTeTunnelStaticCrlspEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The entry in this table describes static-crlsp information."
INDEX { hpnicfTeTunnelStaticCrlspInLabel }
::= { hpnicfTeTunnelStaticCrlspTable 1 }
HpnicfTeTunnelStaticCrlspEntry ::=
SEQUENCE {
hpnicfTeTunnelStaticCrlspInLabel
MplsLabel,
hpnicfTeTunnelStaticCrlspName
OCTET STRING,
hpnicfTeTunnelStaticCrlspStatus
INTEGER,
hpnicfTeTunnelStaticCrlspRole
INTEGER,
hpnicfTeTunnelStaticCrlspXCPointer
RowPointer
}
hpnicfTeTunnelStaticCrlspInLabel OBJECT-TYPE
SYNTAX MplsLabel
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This is unique label value that manualy assigned. Uniquely
identifies a static-crlsp. Managers should use this to obtain
detail static-crlsp information."
::= { hpnicfTeTunnelStaticCrlspEntry 1 }
hpnicfTeTunnelStaticCrlspName OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (1..15))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The unique name assigned to the static-crlsp."
::= { hpnicfTeTunnelStaticCrlspEntry 2 }
hpnicfTeTunnelStaticCrlspStatus OBJECT-TYPE
SYNTAX INTEGER
{
up(1),
down(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the actual status of this static-crlsp,
The value must be up when the static-crlsp status is up and
the value must be down when the static-crlsp status is down."
::= { hpnicfTeTunnelStaticCrlspEntry 3 }
hpnicfTeTunnelStaticCrlspRole OBJECT-TYPE
SYNTAX INTEGER
{
transit(1),
tail(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This value indicate the role of this static-crlsp. This value must
be transit at transit point of the tunnel, and tail at
terminating point of the tunnel."
::= { hpnicfTeTunnelStaticCrlspEntry 4 }
hpnicfTeTunnelStaticCrlspXCPointer OBJECT-TYPE
SYNTAX RowPointer
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This pointer unique identify a row of mplsXCTable.
This value should be zeroDotZero when the static-crlsp
is down. The mplsXCTable identifies the segments that
compose this tunnel, their characteristics, and relationships
to each other."
::= { hpnicfTeTunnelStaticCrlspEntry 5 }
hpnicfTeTunnelCoTable OBJECT-TYPE
SYNTAX SEQUENCE OF HpnicfTeTunnelCoEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table contains information for Co-routed reverse crlsp and
infomation of Co-routed bidirectional Tunnel Interface.
If hpnicfCorouteTunnelLspInstance is zero, to obtain infomation of
Co-routed bidirectional Tunnel Interface, otherwise to obtain
Co-routed reverse crlsp infomation."
::= { hpnicfTeTunnelObjects 2 }
hpnicfTeTunnelCoEntry OBJECT-TYPE
SYNTAX HpnicfTeTunnelCoEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The entry in this table describes Co-routed infomation of
bidirectional Tunnel Interface and reserver lsp information."
INDEX { hpnicfTeTunnelCoIndex, hpnicfTeTunnelCoLspInstance, hpnicfTeTunnelCoIngressLSRId, hpnicfTeTunnelCoEgressLSRId }
::= { hpnicfTeTunnelCoTable 1 }
HpnicfTeTunnelCoEntry ::=
SEQUENCE {
hpnicfTeTunnelCoIndex
MplsTunnelIndex,
hpnicfTeTunnelCoLspInstance
MplsTunnelInstanceIndex,
hpnicfTeTunnelCoIngressLSRId
MplsExtendedTunnelId,
hpnicfTeTunnelCoEgressLSRId
MplsExtendedTunnelId,
hpnicfTeTunnelCoBiMode
INTEGER,
hpnicfTeTunnelCoReverseLspInstance
MplsTunnelInstanceIndex,
hpnicfTeTunnelCoReverseLspXCPointer
RowPointer
}
hpnicfTeTunnelCoIndex OBJECT-TYPE
SYNTAX MplsTunnelIndex
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Uniquely identifies a set of tunnel instances between a pair
of ingress and egress LSRs that specified at originating point.
This value should be equal to the value signaled in the
Tunnel Id of the Session object."
::= { hpnicfTeTunnelCoEntry 1 }
hpnicfTeTunnelCoLspInstance OBJECT-TYPE
SYNTAX MplsTunnelInstanceIndex
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"When obtain infomation of Co-routed bidirectional Tunnel Interface,
this vlaue should be zero. And this value must be LspID to obtain
reverse crlsp information. Values greater than 0, but less than or
equal to 65535, should be useless."
::= { hpnicfTeTunnelCoEntry 2 }
hpnicfTeTunnelCoIngressLSRId OBJECT-TYPE
SYNTAX MplsExtendedTunnelId
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Identity the ingress LSR associated with this tunnel instance.
This vlaue is equal to the LsrID of originating endpoint."
::= { hpnicfTeTunnelCoEntry 3 }
hpnicfTeTunnelCoEgressLSRId OBJECT-TYPE
SYNTAX MplsExtendedTunnelId
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Identity of the egress LSR associated with this tunnel instance.
This vlaue is equal to the LsrID of terminating point."
::= { hpnicfTeTunnelCoEntry 4 }
hpnicfTeTunnelCoBiMode OBJECT-TYPE
SYNTAX INTEGER
{
coroutedActive(1),
coroutedPassive(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This vlaue indicated the bidirection mode of tunnel interface.
The valuemust be coroutedActive at the originating point of the
tunnel and coroutedPassive at the terminating point."
::= { hpnicfTeTunnelCoEntry 5 }
hpnicfTeTunnelCoReverseLspInstance OBJECT-TYPE
SYNTAX MplsTunnelInstanceIndex
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This value indicated the reverse lsp instance, and
should be equal to obverse lsp instance."
::= { hpnicfTeTunnelCoEntry 6 }
hpnicfTeTunnelCoReverseLspXCPointer OBJECT-TYPE
SYNTAX RowPointer
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This pointer unique index to mplsXCTable of the reverse lsp.
The mplsXCTable identifies the segments that compose this tunnel,
their characteristics, and relationships to each other. A
value of zeroDotZero indicate that there is no crlsp assigned
to this."
::= { hpnicfTeTunnelCoEntry 7 }
hpnicfTeTunnelPsTable OBJECT-TYPE
SYNTAX SEQUENCE OF HpnicfTeTunnelPsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table defines some objects for managers to obtain
TE tunnel Protection Switching group current status information."
::= { hpnicfTeTunnelObjects 3 }
hpnicfTeTunnelPsEntry OBJECT-TYPE
SYNTAX HpnicfTeTunnelPsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The entry in this table describes TE tunnel Protection
Switching group infromation."
INDEX { hpnicfTeTunnelPsIndex, hpnicfTeTunnelPsIngressLSRId, hpnicfTeTunnelPsEgressLSRId }
::= { hpnicfTeTunnelPsTable 1 }
HpnicfTeTunnelPsEntry ::=
SEQUENCE {
hpnicfTeTunnelPsIndex
MplsTunnelIndex,
hpnicfTeTunnelPsIngressLSRId
MplsExtendedTunnelId,
hpnicfTeTunnelPsEgressLSRId
MplsExtendedTunnelId,
hpnicfTeTunnelPsProtectIndex
MplsTunnelIndex,
hpnicfTeTunnelPsProtectIngressLSRId
MplsExtendedTunnelId,
hpnicfTeTunnelPsProtectEgressLSRId
MplsExtendedTunnelId,
hpnicfTeTunnelPsProtectType
INTEGER,
hpnicfTeTunnelPsRevertiveMode
INTEGER,
hpnicfTeTunnelPsWtrTime
Unsigned32,
hpnicfTeTunnelPsHoldOffTime
Unsigned32,
hpnicfTeTunnelPsSwitchMode
INTEGER,
hpnicfTeTunnelPsWorkPathStatus
INTEGER,
hpnicfTeTunnelPsProtectPathStatus
INTEGER,
hpnicfTeTunnelPsSwitchResult
INTEGER
}
hpnicfTeTunnelPsIndex OBJECT-TYPE
SYNTAX MplsTunnelIndex
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Uniquely identifies a TE tunnel Protection Switching group
instance. This value must be equal to the tunnel id of work
tunnel instance."
::= { hpnicfTeTunnelPsEntry 1 }
hpnicfTeTunnelPsIngressLSRId OBJECT-TYPE
SYNTAX MplsExtendedTunnelId
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Identity the ingress LSR associated with work tunnel instance."
::= { hpnicfTeTunnelPsEntry 2 }
hpnicfTeTunnelPsEgressLSRId OBJECT-TYPE
SYNTAX MplsExtendedTunnelId
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Identity of the egress LSR associated with work tunnel instance."
::= { hpnicfTeTunnelPsEntry 3 }
hpnicfTeTunnelPsProtectIndex OBJECT-TYPE
SYNTAX MplsTunnelIndex
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Uniquely identifies a TE tunnel Protection Switching
group instance. This value must be equal to the tunnel
id of TE tunnel Protection Switching group instance."
::= { hpnicfTeTunnelPsEntry 4 }
hpnicfTeTunnelPsProtectIngressLSRId OBJECT-TYPE
SYNTAX MplsExtendedTunnelId
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Identity the ingress LSR associated with TE tunnel
Protection Switching group instance."
::= { hpnicfTeTunnelPsEntry 5 }
hpnicfTeTunnelPsProtectEgressLSRId OBJECT-TYPE
SYNTAX MplsExtendedTunnelId
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Identity of the egress LSR associated with TE tunnel
Protection Switching group instance."
::= { hpnicfTeTunnelPsEntry 6 }
hpnicfTeTunnelPsProtectType OBJECT-TYPE
SYNTAX INTEGER
{
oneToOne(1),
onePlusOne(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This value indicated TE tunnel Protection Switching group
type. The default value is oneToOne."
DEFVAL { oneToOne }
::= { hpnicfTeTunnelPsEntry 7 }
hpnicfTeTunnelPsRevertiveMode OBJECT-TYPE
SYNTAX INTEGER
{
revertive(1),
noRevertive(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This value indicated protect switch mode. The value must be
revertive or nonRevertive, default value is revertive.
"
DEFVAL { revertive }
::= { hpnicfTeTunnelPsEntry 8 }
hpnicfTeTunnelPsWtrTime OBJECT-TYPE
SYNTAX Unsigned32 (0..60)
UNITS "30 seconds"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The cycle time that switch to protect tunnel."
DEFVAL { 24 }
::= { hpnicfTeTunnelPsEntry 9 }
hpnicfTeTunnelPsHoldOffTime OBJECT-TYPE
SYNTAX Unsigned32 (0..20)
UNITS "500ms"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This value is switchback delay time. When detected the work path
fault, switch to protect path after this time."
DEFVAL { 0 }
::= { hpnicfTeTunnelPsEntry 10 }
hpnicfTeTunnelPsSwitchMode OBJECT-TYPE
SYNTAX INTEGER
{
uniDirectional(1),
biDirectional(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This value indicated TE tunnel Protection Switching
group switch mode."
DEFVAL { uniDirectional }
::= { hpnicfTeTunnelPsEntry 11 }
hpnicfTeTunnelPsWorkPathStatus OBJECT-TYPE
SYNTAX INTEGER
{
none(1),
noDefect(2),
inDefect(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This value indicates work path status. none, noDefect, inDefect
will be used."
::= { hpnicfTeTunnelPsEntry 12 }
hpnicfTeTunnelPsProtectPathStatus OBJECT-TYPE
SYNTAX INTEGER
{
none(1),
noDefect(2),
inDefect(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This value indicates protect path status. none, noDefect,
inDefect(3) will be used."
::= { hpnicfTeTunnelPsEntry 13 }
hpnicfTeTunnelPsSwitchResult OBJECT-TYPE
SYNTAX INTEGER
{
workPath(1),
protectPath(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This value indicated current using path is work path or protect
path."
::= { hpnicfTeTunnelPsEntry 14 }
hpnicfTeTunnelNotifications OBJECT IDENTIFIER ::= { hpnicfTeTunnel 3 }
hpnicfTeTunnelNotificationsPrefix OBJECT IDENTIFIER ::= { hpnicfTeTunnelNotifications 0 }
hpnicfTeTunnelPsSwitchWtoP NOTIFICATION-TYPE
OBJECTS { hpnicfTeTunnelPsWorkPathStatus, hpnicfTeTunnelPsProtectPathStatus }
STATUS current
DESCRIPTION
"This notification is generated when protect workgroup switch from
work tunnel to protect tunnel."
::= { hpnicfTeTunnelNotificationsPrefix 1 }
hpnicfTeTunnelPsSwitchPtoW NOTIFICATION-TYPE
OBJECTS { hpnicfTeTunnelPsWorkPathStatus, hpnicfTeTunnelPsProtectPathStatus }
STATUS current
DESCRIPTION
"This notification is generated when protect workgroup switch from
protect tunnel to work tunnel."
::= { hpnicfTeTunnelNotificationsPrefix 2 }
hpnicfTeTunnelConformance OBJECT IDENTIFIER ::= { hpnicfTeTunnel 4 }
hpnicfTeTunnelCompliances OBJECT IDENTIFIER ::= { hpnicfTeTunnelConformance 1 }
hpnicfTeTunnelCompliance MODULE-COMPLIANCE
STATUS current
DESCRIPTION
"The compliance statement for SNMP."
MODULE -- this module
MANDATORY-GROUPS { hpnicfTeTunnelNotificationsGroup, hpnicfTeTunnelScalarsGroup, hpnicfTeTunnelStaticCrlspGroup, hpnicfTeTunnelCorouteGroup, hpnicfTeTunnelPsGroup
}
::= { hpnicfTeTunnelCompliances 1 }
hpnicfTeTunnelGroups OBJECT IDENTIFIER ::= { hpnicfTeTunnelConformance 2 }
hpnicfTeTunnelNotificationsGroup NOTIFICATION-GROUP
NOTIFICATIONS { hpnicfTeTunnelPsSwitchPtoW, hpnicfTeTunnelPsSwitchWtoP }
STATUS current
DESCRIPTION
"This group contains MPLS Te Tunnel traps."
::= { hpnicfTeTunnelGroups 1 }
hpnicfTeTunnelScalarsGroup OBJECT-GROUP
OBJECTS { hpnicfTeTunnelMaxTunnelIndex }
STATUS current
DESCRIPTION
"Scalar object needed to implement MPLS te tunnels."
::= { hpnicfTeTunnelGroups 2 }
hpnicfTeTunnelStaticCrlspGroup OBJECT-GROUP
OBJECTS { hpnicfTeTunnelStaticCrlspName, hpnicfTeTunnelStaticCrlspStatus, hpnicfTeTunnelStaticCrlspRole, hpnicfTeTunnelStaticCrlspXCPointer }
STATUS current
DESCRIPTION
"Objects for quering static-crlsp information."
::= { hpnicfTeTunnelGroups 3 }
hpnicfTeTunnelCorouteGroup OBJECT-GROUP
OBJECTS { hpnicfTeTunnelCoBiMode, hpnicfTeTunnelCoReverseLspInstance, hpnicfTeTunnelCoReverseLspXCPointer }
STATUS current
DESCRIPTION
"Objects for quering Co-routed reverse crlsp information."
::= { hpnicfTeTunnelGroups 4 }
hpnicfTeTunnelPsGroup OBJECT-GROUP
OBJECTS { hpnicfTeTunnelPsProtectIndex, hpnicfTeTunnelPsProtectIngressLSRId, hpnicfTeTunnelPsProtectEgressLSRId, hpnicfTeTunnelPsProtectType, hpnicfTeTunnelPsRevertiveMode,
hpnicfTeTunnelPsWtrTime, hpnicfTeTunnelPsHoldOffTime, hpnicfTeTunnelPsSwitchMode, hpnicfTeTunnelPsWorkPathStatus, hpnicfTeTunnelPsProtectPathStatus,
hpnicfTeTunnelPsSwitchResult }
STATUS current
DESCRIPTION
"Objects for quering protect workgroup information."
::= { hpnicfTeTunnelGroups 5 }