1009 lines
38 KiB
Plaintext
1009 lines
38 KiB
Plaintext
HP-STACK-MIB DEFINITIONS ::= BEGIN
|
|
|
|
IMPORTS
|
|
OBJECT-TYPE, MODULE-IDENTITY, Integer32,
|
|
TimeTicks, NOTIFICATION-TYPE
|
|
FROM SNMPv2-SMI
|
|
OBJECT-GROUP, MODULE-COMPLIANCE, NOTIFICATION-GROUP
|
|
FROM SNMPv2-CONF
|
|
RowStatus, TruthValue, DisplayString
|
|
FROM SNMPv2-TC
|
|
SnmpAdminString
|
|
FROM SNMP-FRAMEWORK-MIB
|
|
PhysicalIndex
|
|
FROM ENTITY-MIB
|
|
hpSwitchBaseMACAddress
|
|
FROM NETSWITCH-MIB
|
|
hpSwitch
|
|
FROM HP-ICF-OID;
|
|
|
|
hpStackMIB MODULE-IDENTITY
|
|
LAST-UPDATED "202101220000Z" -- January 22, 2021
|
|
ORGANIZATION "HP Networking"
|
|
CONTACT-INFO "Hewlett Packard Company
|
|
8000 Foothills Blvd.
|
|
Roseville, CA 95747"
|
|
DESCRIPTION "This MIB module describes objects for managing
|
|
the stacking features."
|
|
|
|
REVISION "202101220000Z" -- January 22, 2021
|
|
DESCRIPTION "Added hpStackCompliance2 and hpStackConfigScalarGroup1"
|
|
|
|
REVISION "202009290000Z" -- September 29, 2020
|
|
DESCRIPTION "Added hpStackCompliance1 and hpStackNotificationsGroup1"
|
|
|
|
REVISION "202009210000Z" -- September 21, 2020
|
|
DESCRIPTION "Added hpStackTopoChange MIB."
|
|
|
|
REVISION "201001030000Z" -- January 3, 2010
|
|
DESCRIPTION "Initial version of this MIB."
|
|
|
|
::= { hpSwitch 69 }
|
|
|
|
|
|
-- Configuration support for Stacking
|
|
hpStackNotifications OBJECT IDENTIFIER ::= { hpStackMIB 0 }
|
|
hpStackObjects OBJECT IDENTIFIER ::= { hpStackMIB 1 }
|
|
hpStackConformance OBJECT IDENTIFIER ::= { hpStackMIB 2 }
|
|
|
|
hpStackConfig OBJECT IDENTIFIER ::= { hpStackObjects 1 }
|
|
|
|
|
|
--*************************************************************
|
|
--* Scalar Group
|
|
--*************************************************************
|
|
hpStackId OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (1..255))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The stack ID uniquely identifies the stack; all
|
|
members of the stack have the same stack ID. A
|
|
switch is considered to be a part of a stack
|
|
When it has the same stack ID as the stack
|
|
commander. The stack ID is valid only when
|
|
hpStackSwitchAdminStatus is true (1). This
|
|
value is set by the first elected commander and
|
|
stays with the stack until the user sets the
|
|
hpStackSwitchAdminStatus to 'false (2)' or when
|
|
hpStackSetStacking is set to 'true (1)' in an
|
|
inactive fragment."
|
|
|
|
::= { hpStackConfig 1 }
|
|
|
|
hpStackOperStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
unAvailable (0),
|
|
disabled (1),
|
|
active (2),
|
|
fragmentInactive (3),
|
|
fragmentActive (4)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This is the current operational status of
|
|
the stack. "
|
|
::= { hpStackConfig 2 }
|
|
|
|
hpStackSetStacking OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This variable allows configuration of a stack
|
|
fragment created by a stack split.
|
|
When set to 'true (1)' in the greater fragment, the
|
|
physically present members of the current stack
|
|
become the only members, and the configuration of
|
|
the missing members is converted to strict
|
|
provisioned configuration.
|
|
|
|
When set to 'true (1)' on a lesser fragment, the
|
|
existing stack information is cleared and a new
|
|
stack ID is created. The switches in the stack will
|
|
become 'active' and retain their configuration.
|
|
|
|
No action is taken when set to 'false (2)' in any
|
|
stack."
|
|
::= { hpStackConfig 3 }
|
|
|
|
hpStackTopology OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
unKnown (0),
|
|
chain (1),
|
|
ring (2),
|
|
mesh (3),
|
|
partialMesh (4)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
" This describes the physical topology of the
|
|
current stack."
|
|
::= { hpStackConfig 4 }
|
|
|
|
hpStackTrapEnable OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
enable (1),
|
|
disable (2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
" This enables or disables the hpStack traps."
|
|
::= { hpStackConfig 5 }
|
|
|
|
hpStackSplitPolicy OBJECT-TYPE
|
|
SYNTAX INTEGER{
|
|
oneFragmentUp (1),
|
|
allFragmentsUp (2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This is to set the split policy for the
|
|
current stack. When there is a stack split,
|
|
setting hpStackSplitPolicy to OneFragmentUp
|
|
results in only one active fragment and
|
|
the rest of the fragments remains inactive.
|
|
Setting hpStackSplitPolicy to AllFragmentsUp
|
|
results in all the fragments to be active."
|
|
DEFVAL { oneFragmentUp }
|
|
::= { hpStackConfig 6 }
|
|
|
|
hpStackMemberCount OBJECT-TYPE
|
|
SYNTAX Integer32 (1..10)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object provides the number of members
|
|
in a stack."
|
|
::= { hpStackConfig 7 }
|
|
|
|
hpStackActiveMemberCount OBJECT-TYPE
|
|
SYNTAX Integer32 (1..10)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object provides the number of active
|
|
members in a stack."
|
|
::= { hpStackConfig 8 }
|
|
|
|
--*************************************************************
|
|
--* hpStackConfigTable
|
|
--*************************************************************
|
|
hpStackConfigTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF HpStackConfigEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "Table to configure basic
|
|
stacking feature."
|
|
::= { hpStackObjects 2 }
|
|
|
|
hpStackConfigEntry OBJECT-TYPE
|
|
SYNTAX HpStackConfigEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "A row in the stack config table."
|
|
INDEX { hpStackSequenceNum }
|
|
::= { hpStackConfigTable 1 }
|
|
|
|
HpStackConfigEntry ::=
|
|
SEQUENCE {
|
|
hpStackSequenceNum Integer32,
|
|
hpStackSwitchAdminStatus INTEGER,
|
|
hpStackSwitchPreferredPriority Integer32,
|
|
hpStackSwitchPreferredMemberId Integer32
|
|
}
|
|
|
|
hpStackSequenceNum OBJECT-TYPE
|
|
SYNTAX Integer32 (1..255)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This is the sequence number to this table.
|
|
At any instance of time only one entry exists."
|
|
::= { hpStackConfigEntry 1 }
|
|
|
|
hpStackSwitchAdminStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
enable (1),
|
|
disable (2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The admin status of the stacking feature. When set
|
|
to 'enable (1)', this will enable stacking on a
|
|
standalone switch that had stacking disabled
|
|
previously. Once stacking is enabled, the switch
|
|
will not have a stack ID and merges automatically
|
|
to any stack it is connected to and learns the
|
|
stack ID of that stack.
|
|
|
|
It has no effect on a switch where stacking is
|
|
already enabled. An error will be returned when
|
|
attempting to set the value to 'enable(1)' on a
|
|
switch that has secure-mode set to enhanced.
|
|
|
|
|
|
Setting this to 'disable (2)' will disable
|
|
stacking on a standalone switch. Once stacking is
|
|
disabled, the stack ports will be kept down. This
|
|
will prevent the switch from ever joining or
|
|
creating a stack. This is allowed only on a
|
|
standalone switch, that is, a switch that is not
|
|
connected over a stacking link to any other
|
|
switch. It has no effect on a switch where
|
|
stacking is already disabled.
|
|
|
|
Enabling or disabling stacking will trigger a
|
|
reboot of the switch.
|
|
|
|
When hpStackSwitchAdminStatus is set to 'true
|
|
(1)', and if the user wants to set the preferred
|
|
priority and the member ID of the switch, then
|
|
hpStackSwitchPreferredPriority and
|
|
hpStackSwitchPreferredMemberId needs to be set
|
|
along with hpStackSwitchAdminStatus. If the
|
|
priority and member ID are not specified, then the
|
|
default values will be used."
|
|
|
|
::= { hpStackConfigEntry 2 }
|
|
|
|
|
|
hpStackSwitchPreferredPriority OBJECT-TYPE
|
|
SYNTAX Integer32 (1..255)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
" This allows the user to set the priority of a
|
|
switch when stacking is enabled on it.
|
|
hpStackSwitchPreferredPriority needs to be set
|
|
along with hpStackSwitchAdminStatus being set to
|
|
'true (1)'.
|
|
|
|
Note that this is to be used only when enabling
|
|
stacking. To set the priority of a switch on
|
|
which stacking is already enabled,
|
|
use hpStackMemberTable.
|
|
|
|
hpStackSwitchPreferredPriority is unused when
|
|
hpStackSwitchAdminStatus is false (2)."
|
|
|
|
::= { hpStackConfigEntry 3 }
|
|
|
|
hpStackSwitchPreferredMemberId OBJECT-TYPE
|
|
SYNTAX Integer32 (1..65535)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
" This allows the user to set the preferred
|
|
member ID of a switch when stacking is enabled on
|
|
it. hpStackSwitchPreferredMemberId needs to be
|
|
set along with setting hpStackSwitchAdminStatus
|
|
being set to 'true (1)'. This entry is useful only
|
|
at the time of setting hpStackSwitchAdminStatus to
|
|
'true (1)'. hpStackSwitchPreferredMemberId is
|
|
unused when hpStackSwitchAdminStatus is set to
|
|
false (2)."
|
|
::= { hpStackConfigEntry 4 }
|
|
|
|
--*************************************************************
|
|
--* hpStackMemberTable
|
|
--*************************************************************
|
|
hpStackMemberTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF HpStackMemberEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "Table to configure stack members."
|
|
::= { hpStackObjects 3 }
|
|
|
|
hpStackMemberEntry OBJECT-TYPE
|
|
SYNTAX HpStackMemberEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "A row in the stack member table."
|
|
INDEX { hpStackMemberId }
|
|
::= { hpStackMemberTable 1 }
|
|
|
|
HpStackMemberEntry ::=
|
|
SEQUENCE {
|
|
hpStackMemberId Integer32,
|
|
hpStackMemberProductId DisplayString,
|
|
hpStackMemberMacAddr OCTET STRING,
|
|
hpStackMemberShutdown TruthValue,
|
|
hpStackMemberReboot TruthValue,
|
|
hpStackMemberAdminPriority Integer32,
|
|
hpStackMemberEntryStatus RowStatus,
|
|
hpStackMemberEntPhysicalIndex PhysicalIndex,
|
|
hpStackMemberState INTEGER,
|
|
hpStackMemberProductName SnmpAdminString,
|
|
hpStackMemberUpTime TimeTicks,
|
|
hpStackMemberSysOid OBJECT IDENTIFIER,
|
|
hpStackMemberIdForTrap Integer32,
|
|
hpStackMemberSerialNum DisplayString,
|
|
hpStackMemberCpuUtil Integer32,
|
|
hpStackMemberTotalMemory Integer32,
|
|
hpStackMemberFreeMemory Integer32,
|
|
hpStackMemberBootRomVersion DisplayString,
|
|
hpStackMemberOsVersion DisplayString,
|
|
hpStackMemberBootImage INTEGER
|
|
}
|
|
|
|
hpStackMemberId OBJECT-TYPE
|
|
SYNTAX Integer32 (1..65535)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This is the member ID of the switch and
|
|
index to this table. This identifies
|
|
each member in the stack."
|
|
::= { hpStackMemberEntry 1 }
|
|
|
|
hpStackMemberProductId OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This is the product ID [J-number] of
|
|
the switch. When a member is provisioned,
|
|
this is a mandatory field. The product must be
|
|
capable of stacking support."
|
|
|
|
::= { hpStackMemberEntry 2 }
|
|
|
|
hpStackMemberMacAddr OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(0|6))
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The MAC address that identifies the member switch.
|
|
The configuration of MAC address will not be
|
|
allowed if another table exists with the same
|
|
MAC address."
|
|
::= { hpStackMemberEntry 3 }
|
|
|
|
|
|
hpStackMemberShutdown OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"For the members that physically exist,
|
|
this will cause the switch to shutdown.
|
|
If the switch is a standby, a new standby
|
|
switch will be chosen.
|
|
To shutdown, it needs to be set to
|
|
'true (1)'. A write operation of 'false (2)'
|
|
leads to no operation. This can be set to
|
|
'true (1)' only if the member physically exists
|
|
and is an active member of the stack. This
|
|
variable cannot be set to 'true (1)' if
|
|
the member ID corresponds to a commander.
|
|
This object will always return 'false (2)'."
|
|
::= { hpStackMemberEntry 4 }
|
|
|
|
hpStackMemberReboot OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Setting this variable to 'true (1)'
|
|
will reboot the switch. A write operation of
|
|
'false (2)' leads to no operation.
|
|
This object will always return 'false (2)'
|
|
Reboot is allowed only when a
|
|
member exist physically."
|
|
::= { hpStackMemberEntry 5 }
|
|
|
|
hpStackMemberAdminPriority OBJECT-TYPE
|
|
SYNTAX Integer32 (1..255)
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This assigns the priority to the member.
|
|
If the stack is rebooted and the members are
|
|
assigned with priorities, then commander will
|
|
be the one with the highest priority and the
|
|
standby will be the one with the next highest
|
|
priority. The following rules apply for assigning
|
|
the priority:
|
|
|
|
1. In the existing stack, if the priority
|
|
is increased, the member is likely to become
|
|
commander only the next time the stack is rebooted,
|
|
it will not be immediately elected as commander.
|
|
|
|
2. A switch with the highest priority will not be elected
|
|
as commander if it is a new member of the stack
|
|
even when the stack is rebooted as it will not have
|
|
the latest configurations.
|
|
|
|
3. If a commander switch with highest priority fails
|
|
over to standby, it will not become commander again
|
|
in the subsequent reboot. The stack itself needs to
|
|
be booted or the failover to this commander should
|
|
happen.
|
|
|
|
4. A switch that joins an already active stack will not
|
|
become the commander even if it has the highest priority.
|
|
|
|
5. If the priority is assigned to the member when it is in
|
|
standalone state and when it joins the stack, if the stack
|
|
configuration has an existing pre-provisioned priority for this
|
|
member, then the pre-provisioned value preempts the
|
|
standalone value.
|
|
|
|
To assign priority to a member, the member can
|
|
either be provisioned or physically present."
|
|
|
|
DEFVAL { 128 }
|
|
::= { hpStackMemberEntry 6 }
|
|
|
|
hpStackMemberEntryStatus OBJECT-TYPE
|
|
SYNTAX RowStatus
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The status of a stack member entry.
|
|
The member entry is created with the
|
|
row status value as createAndGo (4)
|
|
and the hpStackMemberProductId.
|
|
The createAndWait(5) is not
|
|
supported by this mib table.
|
|
To remove the switch from the stack,
|
|
row status is set to destroy (6).
|
|
Setting it to 'destory (6)' is not
|
|
allowed if the member ID corresponds
|
|
to a commander switch.
|
|
|
|
For the physically existing switch,
|
|
if hpStackMemberReboot is set to
|
|
'true (1)' along with the row status to
|
|
'destroy (6), the switch will come up with a
|
|
blank configuration and will acquire a new
|
|
hpStackMemberId."
|
|
::= { hpStackMemberEntry 7 }
|
|
|
|
hpStackMemberEntPhysicalIndex OBJECT-TYPE
|
|
SYNTAX PhysicalIndex
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This gives the index of this member in the
|
|
entPhysicalTable (rfc2737)."
|
|
::= { hpStackMemberEntry 8 }
|
|
|
|
hpStackMemberState OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
unusedId (0),
|
|
missing (1),
|
|
provision (2),
|
|
commander (3),
|
|
standby (4),
|
|
member (5),
|
|
shutdown (6),
|
|
booting (7),
|
|
communicationFailure (8),
|
|
incompatibleOs (9),
|
|
unknownState (10),
|
|
standbyBooting (11)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This gives the status of the switch in the stack.
|
|
unusedId (0) - The member ID does not exist.
|
|
missing (1) - A member switch in the stack when
|
|
it becomes Non responsive, it is
|
|
marked as the missing member. Either
|
|
the stack link goes down or the stack
|
|
member crashed. Note that it is possible
|
|
to remove even the missing member from
|
|
the stack. In this case, the missing members
|
|
configuration is removed from the
|
|
stack config file.
|
|
provision (2) - A member switch whose config is
|
|
provisioned and that does not exist physically.
|
|
commander (3) - One physical switch whose management
|
|
CPU takes up the role that the
|
|
active management module in
|
|
the 8200 switch would take.
|
|
standby (4) - One physical switch whose management
|
|
CPU takes up the role that the
|
|
standby management module in
|
|
the 8200 switch would take.
|
|
member (5) - A switch that is part of the
|
|
stack.
|
|
shutdown (6) - The switch is in the shutdown
|
|
state.
|
|
booting (7) - The switch is in the booting
|
|
state.
|
|
communicationFailure (8) - This is an error condition.
|
|
The switch cannot be reached.
|
|
incompatibleOs (9) - This is an error condition.
|
|
The member switch runs with a different
|
|
OS image.
|
|
unknownState (10) - The member switch's state cannot be
|
|
determined. This is an error condition.
|
|
standbyBooting (11) - The standby switch is currently
|
|
booting up. When boot is
|
|
completed, the state will be
|
|
'standby (4)'."
|
|
|
|
::= { hpStackMemberEntry 9 }
|
|
|
|
hpStackMemberProductName OBJECT-TYPE
|
|
SYNTAX SnmpAdminString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This gives the product name of the switch."
|
|
::= { hpStackMemberEntry 10 }
|
|
|
|
hpStackMemberUpTime OBJECT-TYPE
|
|
SYNTAX TimeTicks
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This provides the uptime of this specific
|
|
member. This is different from the stack
|
|
uptime."
|
|
::= { hpStackMemberEntry 11 }
|
|
|
|
hpStackMemberSysOid OBJECT-TYPE
|
|
SYNTAX OBJECT IDENTIFIER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This provides the sysObjectId of this
|
|
specific member."
|
|
::= { hpStackMemberEntry 12 }
|
|
|
|
hpStackMemberIdForTrap OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This is same as hpStackMemberId.
|
|
This is useful only for the notifications."
|
|
::= { hpStackMemberEntry 13 }
|
|
|
|
hpStackMemberSerialNum OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This is the serial number of
|
|
the member switch."
|
|
::= { hpStackMemberEntry 14 }
|
|
|
|
hpStackMemberCpuUtil OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This is the percantage of CPU utilization
|
|
of the member the switch."
|
|
::= { hpStackMemberEntry 15 }
|
|
|
|
hpStackMemberTotalMemory OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This is the total memory usage in bytes of the
|
|
member switch."
|
|
::= { hpStackMemberEntry 16 }
|
|
|
|
hpStackMemberFreeMemory OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This is the free memory available, in bytes, on
|
|
the member switch."
|
|
::= { hpStackMemberEntry 17 }
|
|
|
|
hpStackMemberBootRomVersion OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This is the boot ROM version in the member
|
|
switch."
|
|
::= { hpStackMemberEntry 18 }
|
|
|
|
hpStackMemberOsVersion OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This is the switch operating system version on
|
|
the member switch."
|
|
::= { hpStackMemberEntry 19 }
|
|
|
|
hpStackMemberBootImage OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
primary (1),
|
|
secondary (2)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This is the boot image information of the member."
|
|
::= { hpStackMemberEntry 20 }
|
|
|
|
--*************************************************************
|
|
--* hpStackPortTable
|
|
--*************************************************************
|
|
hpStackPortTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF HpStackPortEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "Table of info about the stack ports."
|
|
::= { hpStackObjects 5 }
|
|
|
|
hpStackPortEntry OBJECT-TYPE
|
|
SYNTAX HpStackPortEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "A row in the stack port table."
|
|
INDEX { hpStackMemberId,
|
|
hpStackPortId,
|
|
hpStackPortType
|
|
}
|
|
::= { hpStackPortTable 1 }
|
|
|
|
HpStackPortEntry ::=
|
|
SEQUENCE {
|
|
hpStackPortId Integer32,
|
|
hpStackPortType INTEGER,
|
|
hpStackPortOperStatus INTEGER,
|
|
hpStackPortNeighbor OCTET STRING,
|
|
hpStackPortCost Integer32,
|
|
hpStackPortIdForTrap Integer32,
|
|
hpStackPortTypeForTrap INTEGER,
|
|
hpStackPortAdminStatus INTEGER
|
|
}
|
|
|
|
|
|
hpStackPortId OBJECT-TYPE
|
|
SYNTAX Integer32 (1..65535)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This is the stack port ID."
|
|
::= { hpStackPortEntry 1 }
|
|
|
|
hpStackPortType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
backPlane (1),
|
|
frontPlane (2)
|
|
}
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This is the stack port type."
|
|
::= { hpStackPortEntry 2 }
|
|
|
|
hpStackPortOperStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
up (1),
|
|
down (2),
|
|
disabled (3),
|
|
blocked (4)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This gives the stack port state."
|
|
::= { hpStackPortEntry 3 }
|
|
|
|
hpStackPortNeighbor OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (1..255))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This contains the value of the
|
|
hpStackMemberId and hpStackPortId
|
|
of the switch's chassis to which this
|
|
stack port is connected. If the
|
|
stack port is not connected, it returns
|
|
a value of zero."
|
|
::= { hpStackPortEntry 4 }
|
|
|
|
hpStackPortCost OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This gives the stack port cost."
|
|
::= { hpStackPortEntry 5 }
|
|
|
|
hpStackPortIdForTrap OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This is same as hpStackPortId.
|
|
This is useful only for the notifications."
|
|
::= { hpStackPortEntry 6 }
|
|
|
|
hpStackPortTypeForTrap OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
backPlane (1),
|
|
frontPlane (2)
|
|
}
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This is same as hpStackPortType.
|
|
This is useful only for the notifications."
|
|
::= { hpStackPortEntry 7 }
|
|
|
|
hpStackPortAdminStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
enable (1),
|
|
disable (2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Setting this variable to 'enable(1)' is allowed only when
|
|
hpStackPortOperStatus is in 'disabled(3)' state.
|
|
A set operation of disable(2) is not allowed.
|
|
A get operation on this returns 'enabled' only when
|
|
the hpStackPortOperStatus is up."
|
|
::={ hpStackPortEntry 8 }
|
|
|
|
|
|
--*************************************************************
|
|
--* hpStackNotifications
|
|
--*************************************************************
|
|
hpStackPortChange NOTIFICATION-TYPE
|
|
OBJECTS { hpStackMemberIdForTrap,
|
|
hpStackPortIdForTrap,
|
|
hpStackPortTypeForTrap,
|
|
hpStackPortOperStatus,
|
|
hpStackPortNeighbor
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This notification is generated when the state
|
|
of a stack port has changed."
|
|
::= { hpStackNotifications 1 }
|
|
|
|
hpStackCommanderChange NOTIFICATION-TYPE
|
|
OBJECTS { hpStackMemberIdForTrap,
|
|
hpStackMemberState
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This notification is generated when a new commander
|
|
first comes up. The notification is also sent when
|
|
a failover happens, and the standby becomes commander or
|
|
when the commander is down."
|
|
::= { hpStackNotifications 2 }
|
|
|
|
hpStackMemberChange NOTIFICATION-TYPE
|
|
OBJECTS { hpStackMemberIdForTrap,
|
|
hpStackMemberState
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This notification is generated when a new member joins
|
|
the stack or when it moves from a loose provisioned to
|
|
strict provisioned."
|
|
::= { hpStackNotifications 3 }
|
|
|
|
hpStackMemberStatusChange NOTIFICATION-TYPE
|
|
OBJECTS { hpStackMemberIdForTrap,
|
|
hpSwitchBaseMACAddress,
|
|
hpStackMemberState
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This notification is generated when a member becomes
|
|
active or inactive."
|
|
::= { hpStackNotifications 4 }
|
|
|
|
hpStackMergeFailed NOTIFICATION-TYPE
|
|
OBJECTS { hpStackMemberIdForTrap,
|
|
hpStackMemberState,
|
|
hpStackId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This notification is generated when a new member
|
|
attempts to join the stack, but was denied.
|
|
This could be because of:
|
|
a. Merge policy of stack prevents the switch from joining
|
|
b. Merge policy of switch prevents it from joining
|
|
c. Stacking disabled on switch
|
|
d. No available member ID's on stack
|
|
e. Switch is incorrectly provisioned
|
|
(wrong J-Number, correct MAC).
|
|
hpStackId here is the other Stack Id."
|
|
::= { hpStackNotifications 5 }
|
|
|
|
hpStackMergeSuccess NOTIFICATION-TYPE
|
|
OBJECTS { hpStackMemberIdForTrap,
|
|
hpStackMemberState,
|
|
hpStackId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This notification is generated when a new member
|
|
attempts to join the stack and have successfully merged.
|
|
This will be sent by each stack that got merged."
|
|
::= { hpStackNotifications 6 }
|
|
|
|
hpStackTopoChange NOTIFICATION-TYPE
|
|
OBJECTS { hpStackMemberIdForTrap,
|
|
hpStackTopology
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This notification is generated when the topology of
|
|
the stack changes."
|
|
::= { hpStackNotifications 7 }
|
|
|
|
--*************************************************************
|
|
--* hpStackNotifications
|
|
--*************************************************************
|
|
hpStackCompliances OBJECT IDENTIFIER ::=
|
|
{ hpStackConformance 1 }
|
|
hpStackGroups OBJECT IDENTIFIER ::=
|
|
{ hpStackConformance 2 }
|
|
|
|
hpStackCompliance MODULE-COMPLIANCE
|
|
STATUS deprecated
|
|
DESCRIPTION "The compliance statement for the hpStack mib."
|
|
MODULE -- this module
|
|
MANDATORY-GROUPS
|
|
{
|
|
hpStackConfigScalarGroup,
|
|
hpStackMemberGroup,
|
|
hpStackPortGroup,
|
|
hpStackNotificationsGroup
|
|
}
|
|
|
|
::= { hpStackCompliances 1 }
|
|
|
|
hpStackCompliance1 MODULE-COMPLIANCE
|
|
STATUS deprecated
|
|
DESCRIPTION "The compliance statement for the hpStack mib."
|
|
MODULE -- this module
|
|
MANDATORY-GROUPS
|
|
{
|
|
hpStackConfigScalarGroup,
|
|
hpStackMemberGroup,
|
|
hpStackPortGroup,
|
|
hpStackNotificationsGroup1
|
|
}
|
|
|
|
::= { hpStackCompliances 2 }
|
|
|
|
hpStackCompliance2 MODULE-COMPLIANCE
|
|
STATUS current
|
|
DESCRIPTION "The compliance statement for the hpStack mib."
|
|
MODULE -- this module
|
|
MANDATORY-GROUPS
|
|
{
|
|
hpStackConfigScalarGroup1,
|
|
hpStackMemberGroup,
|
|
hpStackPortGroup,
|
|
hpStackNotificationsGroup1
|
|
}
|
|
|
|
::= { hpStackCompliances 3 }
|
|
|
|
hpStackConfigScalarGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
hpStackId,
|
|
hpStackOperStatus,
|
|
hpStackSetStacking,
|
|
hpStackTopology,
|
|
hpStackTrapEnable,
|
|
hpStackSwitchAdminStatus,
|
|
hpStackSwitchPreferredPriority,
|
|
hpStackSwitchPreferredMemberId,
|
|
hpStackSplitPolicy
|
|
}
|
|
STATUS deprecated
|
|
DESCRIPTION "A collection of objects for the basic stack configuration."
|
|
::= { hpStackGroups 1 }
|
|
|
|
hpStackMemberGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
hpStackMemberProductId,
|
|
hpStackMemberMacAddr,
|
|
hpStackMemberShutdown,
|
|
hpStackMemberReboot,
|
|
hpStackMemberAdminPriority,
|
|
hpStackMemberEntryStatus,
|
|
hpStackMemberEntPhysicalIndex,
|
|
hpStackMemberState,
|
|
hpStackMemberProductName,
|
|
hpStackMemberUpTime,
|
|
hpStackMemberSysOid,
|
|
hpStackMemberIdForTrap,
|
|
hpStackMemberSerialNum,
|
|
hpStackMemberCpuUtil,
|
|
hpStackMemberTotalMemory,
|
|
hpStackMemberFreeMemory,
|
|
hpStackMemberBootRomVersion,
|
|
hpStackMemberOsVersion,
|
|
hpStackMemberBootImage
|
|
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "A collection of objects for the configuring a
|
|
member switch of the stack."
|
|
::= { hpStackGroups 2 }
|
|
|
|
hpStackPortGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
hpStackPortOperStatus,
|
|
hpStackPortNeighbor,
|
|
hpStackPortCost,
|
|
hpStackPortIdForTrap,
|
|
hpStackPortTypeForTrap,
|
|
hpStackPortAdminStatus
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "A collection of objects providing
|
|
information about the stack ports."
|
|
::= { hpStackGroups 3 }
|
|
|
|
hpStackNotificationsGroup NOTIFICATION-GROUP
|
|
NOTIFICATIONS {
|
|
hpStackPortChange,
|
|
hpStackCommanderChange,
|
|
hpStackMemberChange,
|
|
hpStackMemberStatusChange,
|
|
hpStackMergeFailed,
|
|
hpStackMergeSuccess
|
|
}
|
|
STATUS deprecated
|
|
DESCRIPTION "A collection of objects providing
|
|
information about the stack ports."
|
|
::= { hpStackGroups 4 }
|
|
|
|
hpStackNotificationsGroup1 NOTIFICATION-GROUP
|
|
NOTIFICATIONS {
|
|
hpStackPortChange,
|
|
hpStackCommanderChange,
|
|
hpStackMemberChange,
|
|
hpStackMemberStatusChange,
|
|
hpStackMergeFailed,
|
|
hpStackMergeSuccess,
|
|
hpStackTopoChange
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "A collection of objects providing
|
|
information about the stack ports."
|
|
::= { hpStackGroups 5 }
|
|
|
|
hpStackConfigScalarGroup1 OBJECT-GROUP
|
|
OBJECTS {
|
|
hpStackId,
|
|
hpStackOperStatus,
|
|
hpStackSetStacking,
|
|
hpStackTopology,
|
|
hpStackTrapEnable,
|
|
hpStackSwitchAdminStatus,
|
|
hpStackSwitchPreferredPriority,
|
|
hpStackSwitchPreferredMemberId,
|
|
hpStackSplitPolicy,
|
|
hpStackMemberCount,
|
|
hpStackActiveMemberCount
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "A collection of objects for the basic stack configuration."
|
|
::= { hpStackGroups 6 }
|
|
END
|