8204 lines
328 KiB
Plaintext
8204 lines
328 KiB
Plaintext
|
||
-- (C) COPYRIGHT HEWLETT-PACKARD COMPANY 2016.
|
||
--
|
||
-- HP PageWide Pro 477dw MFP Printer Model Specific MIB.
|
||
-- Version - 1.0
|
||
-- Generated on Jan. 29, 2016 .
|
||
--
|
||
-- Company names and product names mentioned herein may be
|
||
-- trademarks, and/or registered trademarks of their respective
|
||
-- companies.
|
||
--
|
||
-- This MIB describes all the printer model specific
|
||
-- objects supported by the HP PageWide Pro 477dw MFP printer
|
||
-- when networked connected.
|
||
--
|
||
-- This MIB complies with the following dependencies:
|
||
--
|
||
-- Printer-MIB
|
||
-- IF-MIB
|
||
-- SNMP-FRAMEWORK-MIB
|
||
-- IANAifType-MIB
|
||
-- SNMP-USER-BASED-SM-MIB
|
||
-- INET-ADDRESS-MIB
|
||
-- HOST-RESOURCES-MIB
|
||
-- IANA-CHARSET-MIB
|
||
-- IEEE802dot11-MIB
|
||
-- SNMPv2-TC
|
||
-- IANA-PRINTER-MIB
|
||
--
|
||
--
|
||
|
||
HP-PAGEWIDE-PRO-477DW-MFP-MIB DEFINITIONS ::= BEGIN
|
||
|
||
IMPORTS
|
||
PrtLocalizedDescriptionStringTC , PrtMediaUnitTC , PrtCapacityUnitTC , PrtSubUnitStatusTC , PresentOnOff , PrtOutputStackingOrderTC , PrtOutputPageDeliveryOrientationTC , PrtMarkerCounterUnitTC , PrtMarkerAddressabilityUnitTC , PrtMarkerSuppliesClassTC , PrtMarkerSuppliesSupplyUnitTC , PrtMarkerColorantRoleTC , PrtMediaPathMaxSpeedPrintUnitTC , PrtChannelStateTC , PrtPrintOrientationTC , PrtInterpreterTwoWayTC , PrtConsoleDescriptionStringTC
|
||
FROM Printer-MIB
|
||
InterfaceIndex , InterfaceIndexOrZero
|
||
FROM IF-MIB
|
||
SnmpAdminString , SnmpEngineID
|
||
FROM SNMP-FRAMEWORK-MIB
|
||
IANAifType
|
||
FROM IANAifType-MIB
|
||
KeyChange
|
||
FROM SNMP-USER-BASED-SM-MIB
|
||
InetAddress
|
||
FROM INET-ADDRESS-MIB
|
||
InternationalDisplayString , KBytes , ProductID
|
||
FROM HOST-RESOURCES-MIB
|
||
IANACharset
|
||
FROM IANA-CHARSET-MIB
|
||
WEPKeytype
|
||
FROM IEEE802dot11-MIB
|
||
TruthValue , DisplayString , TimeStamp , PhysAddress , DateAndTime , AutonomousType , TestAndIncr , RowPointer , StorageType , RowStatus
|
||
FROM SNMPv2-TC
|
||
PrtGeneralResetTC , PrtCoverStatusTC , PrtInputTypeTC , PrtOutputTypeTC , PrtMarkerMarkTechTC , PrtMarkerSuppliesTypeTC , PrtMediaPathTypeTC , PrtChannelTypeTC , PrtInterpreterLangFamilyTC
|
||
FROM IANA-PRINTER-MIB;
|
||
|
||
org OBJECT IDENTIFIER ::= { iso(1) 3 }
|
||
snmpV2 OBJECT IDENTIFIER ::= { internet 6 }
|
||
private OBJECT IDENTIFIER ::= { internet 4 }
|
||
netPML OBJECT IDENTIFIER ::= { netPeripheral 4 }
|
||
dod OBJECT IDENTIFIER ::= { org 6 }
|
||
snmpModules OBJECT IDENTIFIER ::= { snmpV2 3 }
|
||
enterprises OBJECT IDENTIFIER ::= { private 1 }
|
||
hpPrintServer OBJECT IDENTIFIER ::= { enterprises 11 }
|
||
netPMLmgmt OBJECT IDENTIFIER ::= { netPML 2 }
|
||
nm-system OBJECT IDENTIFIER ::= { nm 3 }
|
||
printmib OBJECT IDENTIFIER ::= { mib-2 43 }
|
||
internet OBJECT IDENTIFIER ::= { dod 1 }
|
||
ieee802dot11 OBJECT IDENTIFIER ::= { 1 2 840 10036 }
|
||
snmpVacmMIB OBJECT IDENTIFIER ::= { snmpModules 16 }
|
||
snmpUsmMIB OBJECT IDENTIFIER ::= { snmpModules 15 }
|
||
snmpMPDMIB OBJECT IDENTIFIER ::= { snmpModules 11 }
|
||
snmpFrameworkMIB OBJECT IDENTIFIER ::= { snmpModules 10 }
|
||
ppmPort OBJECT IDENTIFIER ::= { ppmMIBObjects 3 }
|
||
ppmPrinter OBJECT IDENTIFIER ::= { ppmMIBObjects 2 }
|
||
ppmMIB OBJECT IDENTIFIER ::= { enterprises pwg(2699) mibs(1) ppmMIB(2) }
|
||
nm OBJECT IDENTIFIER ::= { hpPrintServer 2 }
|
||
interface OBJECT IDENTIFIER ::= { nm 4 }
|
||
consumables OBJECT IDENTIFIER ::= { print-engine 10 }
|
||
destination-subsystem OBJECT IDENTIFIER ::= { device 4 }
|
||
processing-subsystem OBJECT IDENTIFIER ::= { device 3 }
|
||
source-subsystem OBJECT IDENTIFIER ::= { device 2 }
|
||
device OBJECT IDENTIFIER ::= { netPMLmgmt 1 }
|
||
netPeripheral OBJECT IDENTIFIER ::= { nm-system 9 }
|
||
prtConsoleDisplayBuffer OBJECT IDENTIFIER ::= { printmib 16 }
|
||
prtInterpreter OBJECT IDENTIFIER ::= { printmib 15 }
|
||
prtChannel OBJECT IDENTIFIER ::= { printmib 14 }
|
||
prtMediaPath OBJECT IDENTIFIER ::= { printmib 13 }
|
||
prtMarkerColorant OBJECT IDENTIFIER ::= { printmib 12 }
|
||
prtMarkerSupplies OBJECT IDENTIFIER ::= { printmib 11 }
|
||
prtMarker OBJECT IDENTIFIER ::= { printmib 10 }
|
||
prtOutput OBJECT IDENTIFIER ::= { printmib 9 }
|
||
prtInput OBJECT IDENTIFIER ::= { printmib 8 }
|
||
prtLocalization OBJECT IDENTIFIER ::= { printmib 7 }
|
||
prtCover OBJECT IDENTIFIER ::= { printmib 6 }
|
||
prtGeneral OBJECT IDENTIFIER ::= { printmib 5 }
|
||
hrDevice OBJECT IDENTIFIER ::= { host 3 }
|
||
mgmt OBJECT IDENTIFIER ::= { internet 2 }
|
||
ieee802dot11i OBJECT IDENTIFIER ::= { ieee802dot11 7 }
|
||
dot11phy OBJECT IDENTIFIER ::= { ieee802dot11 4 }
|
||
dot11smt OBJECT IDENTIFIER ::= { ieee802dot11 1 }
|
||
vacmViewTreeFamilyTable OBJECT IDENTIFIER ::= { vacmMIBViews 2 }
|
||
vacmMIBObjects OBJECT IDENTIFIER ::= { snmpVacmMIB 1 }
|
||
vacmAccessTable OBJECT IDENTIFIER ::= { vacmMIBObjects 4 }
|
||
vacmSecurityToGroupTable OBJECT IDENTIFIER ::= { vacmMIBObjects 2 }
|
||
vacmContextTable OBJECT IDENTIFIER ::= { vacmMIBObjects 1 }
|
||
usmUserTable OBJECT IDENTIFIER ::= { usmUser 2 }
|
||
usmMIBObjects OBJECT IDENTIFIER ::= { snmpUsmMIB 1 }
|
||
snmpMPDMIBObjects OBJECT IDENTIFIER ::= { snmpMPDMIB 2 }
|
||
snmpFrameworkMIBObjects OBJECT IDENTIFIER ::= { snmpFrameworkMIB 2 }
|
||
ppmPortTable OBJECT IDENTIFIER ::= { ppmPort 1 }
|
||
ppmPrinterTable OBJECT IDENTIFIER ::= { ppmPrinter 1 }
|
||
ppmMIBObjects OBJECT IDENTIFIER ::= { ppmMIB 1 }
|
||
snmpAccess OBJECT IDENTIFIER ::= { nm 15 }
|
||
trap OBJECT IDENTIFIER ::= { nm 13 }
|
||
npSecurityDot11SSIDTable OBJECT IDENTIFIER ::= { npSecurity 9 }
|
||
npSecurityDot11EncryptedWEPKeyTable OBJECT IDENTIFIER ::= { npSecurity 7 }
|
||
npNpi OBJECT IDENTIFIER ::= { npCard 8 }
|
||
npCard OBJECT IDENTIFIER ::= { interface 3 }
|
||
consumables-1 OBJECT IDENTIFIER ::= { consumables 1 }
|
||
media-info OBJECT IDENTIFIER ::= { print-media 3 }
|
||
print-media OBJECT IDENTIFIER ::= { print-engine 8 }
|
||
intrays OBJECT IDENTIFIER ::= { intray 3 }
|
||
intray OBJECT IDENTIFIER ::= { print-engine 3 }
|
||
print-engine OBJECT IDENTIFIER ::= { destination-subsystem 1 }
|
||
fax-proc-sub OBJECT IDENTIFIER ::= { processing-subsystem 7 }
|
||
pdl OBJECT IDENTIFIER ::= { processing-subsystem 3 }
|
||
scanner OBJECT IDENTIFIER ::= { source-subsystem 2 }
|
||
printer-color-accounting OBJECT IDENTIFIER ::= { accounting 3 }
|
||
accounting OBJECT IDENTIFIER ::= { device-system 16 }
|
||
errorlog OBJECT IDENTIFIER ::= { device-system 11 }
|
||
active-print-jobs OBJECT IDENTIFIER ::= { job 2 }
|
||
job OBJECT IDENTIFIER ::= { device-system 6 }
|
||
device-system OBJECT IDENTIFIER ::= { device 1 }
|
||
netPrinter OBJECT IDENTIFIER ::= { netPeripheral 1 }
|
||
prtConsoleDisplayBufferTable OBJECT IDENTIFIER ::= { prtConsoleDisplayBuffer 5 }
|
||
prtInterpreterTable OBJECT IDENTIFIER ::= { prtInterpreter 1 }
|
||
prtChannelTable OBJECT IDENTIFIER ::= { prtChannel 1 }
|
||
prtMediaPathTable OBJECT IDENTIFIER ::= { prtMediaPath 4 }
|
||
prtMarkerColorantTable OBJECT IDENTIFIER ::= { prtMarkerColorant 1 }
|
||
prtMarkerSuppliesTable OBJECT IDENTIFIER ::= { prtMarkerSupplies 1 }
|
||
prtMarkerTable OBJECT IDENTIFIER ::= { prtMarker 2 }
|
||
prtOutputTable OBJECT IDENTIFIER ::= { prtOutput 2 }
|
||
prtInputTable OBJECT IDENTIFIER ::= { prtInput 2 }
|
||
prtLocalizationTable OBJECT IDENTIFIER ::= { prtLocalization 1 }
|
||
prtCoverTable OBJECT IDENTIFIER ::= { prtCover 1 }
|
||
prtGeneralTable OBJECT IDENTIFIER ::= { prtGeneral 1 }
|
||
ifMIB OBJECT IDENTIFIER ::= { mib-2 31 }
|
||
hrPrinterTable OBJECT IDENTIFIER ::= { hrDevice 5 }
|
||
hrDeviceTable OBJECT IDENTIFIER ::= { hrDevice 2 }
|
||
hrStorageTable OBJECT IDENTIFIER ::= { hrStorage 3 }
|
||
host OBJECT IDENTIFIER ::= { mib-2 25 }
|
||
ipNetToMediaTable OBJECT IDENTIFIER ::= { ip 22 }
|
||
ipRouteTable OBJECT IDENTIFIER ::= { ip 21 }
|
||
ipAddrTable OBJECT IDENTIFIER ::= { ip 20 }
|
||
ifTable OBJECT IDENTIFIER ::= { interfaces 2 }
|
||
mib-2 OBJECT IDENTIFIER ::= { mgmt 1 }
|
||
dot11RSNConfigAuthenticationSuitesTable OBJECT IDENTIFIER ::= { ieee802dot11i 3 }
|
||
dot11PhyOperationTable OBJECT IDENTIFIER ::= { dot11phy 1 }
|
||
dot11PrivacyTable OBJECT IDENTIFIER ::= { dot11smt 5 }
|
||
dot11WEPDefaultKeysTable OBJECT IDENTIFIER ::= { dot11smt 3 }
|
||
dot11AuthenticationAlgorithmsTable OBJECT IDENTIFIER ::= { dot11smt 2 }
|
||
dot11StationConfigTable OBJECT IDENTIFIER ::= { dot11smt 1 }
|
||
vacmViewTreeFamilyEntry OBJECT IDENTIFIER ::= { vacmViewTreeFamilyTable 1 }
|
||
vacmMIBViews OBJECT IDENTIFIER ::= { vacmMIBObjects 5 }
|
||
vacmAccessEntry OBJECT IDENTIFIER ::= { vacmAccessTable 1 }
|
||
vacmSecurityToGroupEntry OBJECT IDENTIFIER ::= { vacmSecurityToGroupTable 1 }
|
||
vacmContextEntry OBJECT IDENTIFIER ::= { vacmContextTable 1 }
|
||
usmUserEntry OBJECT IDENTIFIER ::= { usmUserTable 1 }
|
||
usmUser OBJECT IDENTIFIER ::= { usmMIBObjects 2 }
|
||
usmStats OBJECT IDENTIFIER ::= { usmMIBObjects 1 }
|
||
snmpMPDStats OBJECT IDENTIFIER ::= { snmpMPDMIBObjects 1 }
|
||
snmpEngine OBJECT IDENTIFIER ::= { snmpFrameworkMIBObjects 1 }
|
||
ppmPortEntry OBJECT IDENTIFIER ::= { ppmPortTable 1 }
|
||
ppmPrinterEntry OBJECT IDENTIFIER ::= { ppmPrinterTable 1 }
|
||
ppmGeneral OBJECT IDENTIFIER ::= { ppmMIBObjects 1 }
|
||
community OBJECT IDENTIFIER ::= { snmpAccess 1 }
|
||
trapDest OBJECT IDENTIFIER ::= { trap 1 }
|
||
npSecurityDot11SSIDEntry OBJECT IDENTIFIER ::= { npSecurityDot11SSIDTable 1 }
|
||
npSecurityDot11EncryptedWEPKeyEntry OBJECT IDENTIFIER ::= { npSecurityDot11EncryptedWEPKeyTable 1 }
|
||
npSecurity OBJECT IDENTIFIER ::= { npCard 20 }
|
||
npWeb OBJECT IDENTIFIER ::= { npCard 18 }
|
||
npDhcp OBJECT IDENTIFIER ::= { npCard 16 }
|
||
npPort OBJECT IDENTIFIER ::= { npCard 13 }
|
||
npIpx OBJECT IDENTIFIER ::= { npCard 10 }
|
||
npNpiPeripheralAttributeEntry OBJECT IDENTIFIER ::= { npNpi 3 }
|
||
npCtl OBJECT IDENTIFIER ::= { npCard 7 }
|
||
npTcp OBJECT IDENTIFIER ::= { npCard 6 }
|
||
npCfg OBJECT IDENTIFIER ::= { npCard 5 }
|
||
npSys OBJECT IDENTIFIER ::= { npCard 1 }
|
||
consumable-status OBJECT IDENTIFIER ::= { consumables-1 1 }
|
||
media19 OBJECT IDENTIFIER ::= { media-info 19 }
|
||
media18 OBJECT IDENTIFIER ::= { media-info 18 }
|
||
media17 OBJECT IDENTIFIER ::= { media-info 17 }
|
||
media16 OBJECT IDENTIFIER ::= { media-info 16 }
|
||
media15 OBJECT IDENTIFIER ::= { media-info 15 }
|
||
media14 OBJECT IDENTIFIER ::= { media-info 14 }
|
||
media13 OBJECT IDENTIFIER ::= { media-info 13 }
|
||
media12 OBJECT IDENTIFIER ::= { media-info 12 }
|
||
media11 OBJECT IDENTIFIER ::= { media-info 11 }
|
||
media10 OBJECT IDENTIFIER ::= { media-info 10 }
|
||
media9 OBJECT IDENTIFIER ::= { media-info 9 }
|
||
media8 OBJECT IDENTIFIER ::= { media-info 8 }
|
||
media7 OBJECT IDENTIFIER ::= { media-info 7 }
|
||
media6 OBJECT IDENTIFIER ::= { media-info 6 }
|
||
media5 OBJECT IDENTIFIER ::= { media-info 5 }
|
||
media4 OBJECT IDENTIFIER ::= { media-info 4 }
|
||
media3 OBJECT IDENTIFIER ::= { media-info 3 }
|
||
media2 OBJECT IDENTIFIER ::= { media-info 2 }
|
||
media1 OBJECT IDENTIFIER ::= { media-info 1 }
|
||
settings-print-media OBJECT IDENTIFIER ::= { print-media 1 }
|
||
intray5 OBJECT IDENTIFIER ::= { intrays 5 }
|
||
intray3 OBJECT IDENTIFIER ::= { intrays 3 }
|
||
intray2 OBJECT IDENTIFIER ::= { intrays 2 }
|
||
intray1 OBJECT IDENTIFIER ::= { intrays 1 }
|
||
status-intray OBJECT IDENTIFIER ::= { intray 2 }
|
||
status-prt-eng OBJECT IDENTIFIER ::= { print-engine 2 }
|
||
status-fax-proc-sub OBJECT IDENTIFIER ::= { fax-proc-sub 2 }
|
||
settings-fax-proc-sub OBJECT IDENTIFIER ::= { fax-proc-sub 1 }
|
||
pdl-postscript OBJECT IDENTIFIER ::= { pdl 4 }
|
||
pdl-pcl OBJECT IDENTIFIER ::= { pdl 3 }
|
||
settings-scanner OBJECT IDENTIFIER ::= { scanner 1 }
|
||
printed-media-color-usage OBJECT IDENTIFIER ::= { printer-color-accounting 1 }
|
||
scanner-accounting OBJECT IDENTIFIER ::= { accounting 2 }
|
||
printer-accounting OBJECT IDENTIFIER ::= { accounting 1 }
|
||
printed-media-usage OBJECT IDENTIFIER ::= { printer-accounting 1 }
|
||
error15 OBJECT IDENTIFIER ::= { errorlog 15 }
|
||
error14 OBJECT IDENTIFIER ::= { errorlog 14 }
|
||
error13 OBJECT IDENTIFIER ::= { errorlog 13 }
|
||
error12 OBJECT IDENTIFIER ::= { errorlog 12 }
|
||
error11 OBJECT IDENTIFIER ::= { errorlog 11 }
|
||
error10 OBJECT IDENTIFIER ::= { errorlog 10 }
|
||
error9 OBJECT IDENTIFIER ::= { errorlog 9 }
|
||
error8 OBJECT IDENTIFIER ::= { errorlog 8 }
|
||
error7 OBJECT IDENTIFIER ::= { errorlog 7 }
|
||
error6 OBJECT IDENTIFIER ::= { errorlog 6 }
|
||
error5 OBJECT IDENTIFIER ::= { errorlog 5 }
|
||
error4 OBJECT IDENTIFIER ::= { errorlog 4 }
|
||
error3 OBJECT IDENTIFIER ::= { errorlog 3 }
|
||
error2 OBJECT IDENTIFIER ::= { errorlog 2 }
|
||
error1 OBJECT IDENTIFIER ::= { errorlog 1 }
|
||
job-being-parsed OBJECT IDENTIFIER ::= { active-print-jobs 1 }
|
||
settings-job OBJECT IDENTIFIER ::= { job 1 }
|
||
test OBJECT IDENTIFIER ::= { device-system 5 }
|
||
id OBJECT IDENTIFIER ::= { device-system 3 }
|
||
status-system OBJECT IDENTIFIER ::= { device-system 2 }
|
||
settings-system OBJECT IDENTIFIER ::= { device-system 1 }
|
||
generalDeviceStatus OBJECT IDENTIFIER ::= { netPrinter 1 }
|
||
gdStatusEntry OBJECT IDENTIFIER ::= { generalDeviceStatus 2 }
|
||
prtConsoleDisplayBufferEntry OBJECT IDENTIFIER ::= { prtConsoleDisplayBufferTable 1 }
|
||
prtInterpreterEntry OBJECT IDENTIFIER ::= { prtInterpreterTable 1 }
|
||
prtChannelEntry OBJECT IDENTIFIER ::= { prtChannelTable 1 }
|
||
prtMediaPathEntry OBJECT IDENTIFIER ::= { prtMediaPathTable 1 }
|
||
prtMarkerColorantEntry OBJECT IDENTIFIER ::= { prtMarkerColorantTable 1 }
|
||
prtMarkerSuppliesEntry OBJECT IDENTIFIER ::= { prtMarkerSuppliesTable 1 }
|
||
prtMarkerEntry OBJECT IDENTIFIER ::= { prtMarkerTable 1 }
|
||
prtOutputEntry OBJECT IDENTIFIER ::= { prtOutputTable 1 }
|
||
prtInputEntry OBJECT IDENTIFIER ::= { prtInputTable 1 }
|
||
prtLocalizationEntry OBJECT IDENTIFIER ::= { prtLocalizationTable 1 }
|
||
prtCoverEntry OBJECT IDENTIFIER ::= { prtCoverTable 1 }
|
||
prtGeneralEntry OBJECT IDENTIFIER ::= { prtGeneralTable 1 }
|
||
ifMIBObjects OBJECT IDENTIFIER ::= { ifMIB 1 }
|
||
hrPrinterEntry OBJECT IDENTIFIER ::= { hrPrinterTable 1 }
|
||
hrDeviceEntry OBJECT IDENTIFIER ::= { hrDeviceTable 1 }
|
||
hrStorageEntry OBJECT IDENTIFIER ::= { hrStorageTable 1 }
|
||
hrStorage OBJECT IDENTIFIER ::= { host 2 }
|
||
hrSystem OBJECT IDENTIFIER ::= { host 1 }
|
||
snmp OBJECT IDENTIFIER ::= { mib-2 11 }
|
||
ipNetToMediaEntry OBJECT IDENTIFIER ::= { ipNetToMediaTable 1 }
|
||
ipRouteEntry OBJECT IDENTIFIER ::= { ipRouteTable 1 }
|
||
ipAddrEntry OBJECT IDENTIFIER ::= { ipAddrTable 1 }
|
||
ip OBJECT IDENTIFIER ::= { mib-2 4 }
|
||
ifEntry OBJECT IDENTIFIER ::= { ifTable 1 }
|
||
interfaces OBJECT IDENTIFIER ::= { mib-2 2 }
|
||
system OBJECT IDENTIFIER ::= { mib-2 1 }
|
||
dot11RSNConfigAuthenticationSuitesEntry OBJECT IDENTIFIER ::= { dot11RSNConfigAuthenticationSuitesTable 1 }
|
||
dot11PhyOperationEntry OBJECT IDENTIFIER ::= { dot11PhyOperationTable 1 }
|
||
dot11PrivacyEntry OBJECT IDENTIFIER ::= { dot11PrivacyTable 1 }
|
||
dot11WEPDefaultKeysEntry OBJECT IDENTIFIER ::= { dot11WEPDefaultKeysTable 1 }
|
||
dot11AuthenticationAlgorithmsEntry OBJECT IDENTIFIER ::= { dot11AuthenticationAlgorithmsTable 1 }
|
||
dot11StationConfigEntry OBJECT IDENTIFIER ::= { dot11StationConfigTable 1 }
|
||
|
||
|
||
dot11DesiredSSID OBJECT-TYPE
|
||
SYNTAX OCTET STRING (SIZE(0..32))
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"This attribute reflects the Service Set ID used
|
||
in the DesiredSSID parameter of the most recent
|
||
MLME_Scan.request. This value may be modified
|
||
by an external management entity and used by the
|
||
local SME to make decisions about the Scanning process."
|
||
::= { dot11StationConfigEntry 9 }
|
||
|
||
dot11DesiredBSSType OBJECT-TYPE
|
||
SYNTAX INTEGER { infrastructure(1), independent(2), any(3) }
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"This attribute shall specify the type of BSS the
|
||
station shall use when scanning for a BSS with which
|
||
to synchronize. This value is used to filter Probe
|
||
Response frames and Beacons. When set to infrastructure,
|
||
the station shall only synchronize with a BSS whose
|
||
Capability Information field has the ESS subfield set
|
||
to 1. When set to independent, the station shall only
|
||
synchronize with a BSS whose Capability Information
|
||
field has the IBSS subfield set to 1. When set to
|
||
any, the station may synchronize to either type of
|
||
BSS."
|
||
::= { dot11StationConfigEntry 10 }
|
||
|
||
dot11AuthenticationAlgorithm OBJECT-TYPE
|
||
SYNTAX INTEGER { openSystem (1), sharedKey (2) }
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"This attribute shall be a set of all the authentication
|
||
algorithms supported by the STAs. The following are the
|
||
default values and the associated algorithm.
|
||
Value = 1: Open System
|
||
Value = 2: Shared Key"
|
||
::= { dot11AuthenticationAlgorithmsEntry 2 }
|
||
|
||
dot11AuthenticationAlgorithmsEnable OBJECT-TYPE
|
||
SYNTAX TruthValue
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"This attribute, when true at a station,
|
||
shall enable the acceptance of the authentication
|
||
algorithm described in the corresponding table
|
||
entry in authentication frames received by the
|
||
station that have odd authentication sequence numbers.
|
||
The default value of this attribute shall be 1 for
|
||
the Open System table entry and 2 for all other table entries."
|
||
::= { dot11AuthenticationAlgorithmsEntry 3 }
|
||
|
||
dot11WEPDefaultKeyValue OBJECT-TYPE
|
||
SYNTAX WEPKeytype
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"A WEP default secret key value."
|
||
::= { dot11WEPDefaultKeysEntry 2 }
|
||
|
||
dot11PrivacyInvoked OBJECT-TYPE
|
||
SYNTAX TruthValue
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"When this attribute is true, it shall indicate that the IEEE
|
||
802.11 WEP mechanism is used for transmitting frames of type
|
||
Data. The default value of this attribute shall be false."
|
||
::= { dot11PrivacyEntry 1 }
|
||
|
||
dot11WEPDefaultKeyID OBJECT-TYPE
|
||
SYNTAX INTEGER (0..3)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"This attribute shall indicate the use of the first,
|
||
second, third, or fourth element of the WEPDefaultKeys
|
||
array when set to values of zero, one, two, or three. The
|
||
default value of this attribute shall be 0."
|
||
REFERENCE "ISO/IEC 8802-11:1999, 8.3.2"
|
||
::= { dot11PrivacyEntry 2 }
|
||
|
||
dot11CurrentRegDomain OBJECT-TYPE
|
||
-- SYNTAX Integer32
|
||
SYNTAX INTEGER {fcc(16),
|
||
doc(32),
|
||
etsi(48),
|
||
spain (49),
|
||
france(50),
|
||
mkk (64),
|
||
japan (65) }
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The current regulatory domain this instance of the PMD is
|
||
supporting. This object corresponds to one of the
|
||
RegDomains listed in dot11RegDomainsSupported."
|
||
::= { dot11PhyOperationEntry 2 }
|
||
|
||
dot11RSNConfigAuthenticationSuite OBJECT-TYPE
|
||
SYNTAX OCTET STRING (SIZE(4))
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"An authentication suite. Note that dot1X and PSK may
|
||
not be enabled simultaneously. These are mutually exclusive.
|
||
The first three octets shall form an OUI and the fourth octet a
|
||
cipher/authentication suite within that OUI space.
|
||
00:00:00:1 is dot1X,
|
||
00:00:00:2 is PSK"
|
||
::= { dot11RSNConfigAuthenticationSuitesEntry 2 }
|
||
|
||
dot11RSNConfigAuthenticationSuiteEnabled OBJECT-TYPE
|
||
SYNTAX TruthValue
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"This variable indicates whether the corresponding
|
||
authentication suite is enabled/disabled."
|
||
::= { dot11RSNConfigAuthenticationSuitesEntry 3 }
|
||
|
||
sysDescr OBJECT-TYPE
|
||
SYNTAX DisplayString (SIZE (0..255))
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"A textual description of the entity. This value
|
||
should include the full name and version
|
||
identification of the system's hardware type,
|
||
software operating-system, and networking
|
||
software. It is mandatory that this only contain
|
||
printable ASCII characters."
|
||
::= { system 1 }
|
||
|
||
sysObjectID OBJECT-TYPE
|
||
SYNTAX OBJECT IDENTIFIER
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"The vendor's authoritative identification of the
|
||
network management subsystem contained in the
|
||
entity. This value is allocated within the SMI
|
||
enterprises subtree (1.3.6.1.4.1) and provides an
|
||
easy and unambiguous means for determining `what
|
||
kind of box' is being managed. For example, if
|
||
vendor `Flintstones, Inc.' was assigned the
|
||
subtree 1.3.6.1.4.1.4242, it could assign the
|
||
identifier 1.3.6.1.4.1.4242.1.1 to its `Fred
|
||
Router'."
|
||
::= { system 2 }
|
||
|
||
sysUpTime OBJECT-TYPE
|
||
SYNTAX TimeTicks
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"The time (in hundredths of a second) since the
|
||
network management portion of the system was last
|
||
re-initialized."
|
||
::= { system 3 }
|
||
|
||
sysContact OBJECT-TYPE
|
||
SYNTAX DisplayString (SIZE (0..255))
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"The textual identification of the contact person
|
||
for this managed node, together with information
|
||
on how to contact this person."
|
||
::= { system 4 }
|
||
|
||
sysName OBJECT-TYPE
|
||
SYNTAX DisplayString (SIZE (0..255))
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"An administratively-assigned name for this
|
||
managed node. By convention, this is the node's
|
||
fully-qualified domain name."
|
||
::= { system 5 }
|
||
|
||
sysLocation OBJECT-TYPE
|
||
SYNTAX DisplayString (SIZE (0..255))
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"The physical location of this node (e.g.,
|
||
`telephone closet, 3rd floor')."
|
||
::= { system 6 }
|
||
|
||
sysServices OBJECT-TYPE
|
||
SYNTAX INTEGER (0..127)
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"A value which indicates the set of services that
|
||
this entity primarily offers.
|
||
The value is a sum. This sum initially takes the
|
||
value zero, Then, for each layer, L, in the range
|
||
1 through 7, that this node performs transactions
|
||
for, 2 raised to (L - 1) is added to the sum. For
|
||
example, a node which performs primarily routing
|
||
functions would have a value of 4 (2^(3-1)). In
|
||
contrast, a node which is a host offering
|
||
application services would have a value of 72
|
||
(2^(4-1) + 2^(7-1)). Note that in the context of
|
||
the Internet suite of protocols, values should be
|
||
calculated accordingly:
|
||
layer functionality
|
||
1 physical (e.g., repeaters)
|
||
2 datalink/subnetwork (e.g., bridges)
|
||
3 internet (e.g., IP gateways)
|
||
4 end-to-end (e.g., IP hosts)
|
||
7 applications (e.g., mail relays)
|
||
For systems including OSI protocols, layers 5 and
|
||
6 may also be counted."
|
||
::= { system 7 }
|
||
|
||
sysORLastChange OBJECT-TYPE
|
||
SYNTAX TimeStamp
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The value of sysUpTime at the time of the most recent
|
||
change in state or value of any instance of sysORID."
|
||
::= { system 8 }
|
||
|
||
ifNumber OBJECT-TYPE
|
||
SYNTAX Integer32
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The number of network interfaces (regardless of their
|
||
current state) present on this system."
|
||
::= { interfaces 1 }
|
||
|
||
ifIndex OBJECT-TYPE
|
||
SYNTAX InterfaceIndex
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"A unique value, greater than zero, for each interface. It
|
||
is recommended that values are assigned contiguously
|
||
starting from 1. The value for each interface sub-layer
|
||
must remain constant at least from one re-initialization of
|
||
the entity's network management system to the next re-
|
||
initialization."
|
||
::= { ifEntry 1 }
|
||
|
||
ifDescr OBJECT-TYPE
|
||
SYNTAX DisplayString (SIZE (0..255))
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"A textual string containing information about the
|
||
interface. This string should include the name of the
|
||
manufacturer, the product name and the version of the
|
||
interface hardware/software."
|
||
::= { ifEntry 2 }
|
||
|
||
ifType OBJECT-TYPE
|
||
SYNTAX IANAifType
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The type of interface. Additional values for ifType are
|
||
assigned by the Internet Assigned Numbers Authority (IANA),
|
||
through updating the syntax of the IANAifType textual
|
||
convention."
|
||
::= { ifEntry 3 }
|
||
|
||
ifMtu OBJECT-TYPE
|
||
SYNTAX Integer32
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The size of the largest packet which can be sent/received
|
||
on the interface, specified in octets. For interfaces that
|
||
are used for transmitting network datagrams, this is the
|
||
size of the largest network datagram that can be sent on the
|
||
interface."
|
||
::= { ifEntry 4 }
|
||
|
||
ifSpeed OBJECT-TYPE
|
||
SYNTAX Gauge32
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"An estimate of the interface's current bandwidth in bits
|
||
per second. For interfaces which do not vary in bandwidth
|
||
or for those where no accurate estimation can be made, this
|
||
object should contain the nominal bandwidth. If the
|
||
bandwidth of the interface is greater than the maximum value
|
||
reportable by this object then this object should report its
|
||
maximum value (4,294,967,295) and ifHighSpeed must be used
|
||
to report the interace's speed. For a sub-layer which has
|
||
no concept of bandwidth, this object should be zero."
|
||
::= { ifEntry 5 }
|
||
|
||
ifPhysAddress OBJECT-TYPE
|
||
SYNTAX PhysAddress
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The interface's address at its protocol sub-layer. For
|
||
example, for an 802.x interface, this object normally
|
||
contains a MAC address. The interface's media-specific MIB
|
||
must define the bit and byte ordering and the format of the
|
||
value of this object. For interfaces which do not have such
|
||
an address (e.g., a serial line), this object should contain
|
||
an octet string of zero length."
|
||
::= { ifEntry 6 }
|
||
|
||
ifAdminStatus OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
up(1), -- ready to pass packets
|
||
down(2),
|
||
testing(3) -- in some test mode
|
||
}
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The desired state of the interface. The testing(3) state
|
||
indicates that no operational packets can be passed. When a
|
||
managed system initializes, all interfaces start with
|
||
ifAdminStatus in the down(2) state. As a result of either
|
||
explicit management action or per configuration information
|
||
retained by the managed system, ifAdminStatus is then
|
||
changed to either the up(1) or testing(3) states (or remains
|
||
in the down(2) state)."
|
||
::= { ifEntry 7 }
|
||
|
||
ifOperStatus OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
up(1), -- ready to pass packets
|
||
down(2),
|
||
testing(3), -- in some test mode
|
||
unknown(4), -- status can not be determined
|
||
-- for some reason.
|
||
dormant(5),
|
||
notPresent(6), -- some component is missing
|
||
lowerLayerDown(7) -- down due to state of
|
||
-- lower-layer interface(s)
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The current operational state of the interface. The
|
||
testing(3) state indicates that no operational packets can
|
||
be passed. If ifAdminStatus is down(2) then ifOperStatus
|
||
should be down(2). If ifAdminStatus is changed to up(1)
|
||
then ifOperStatus should change to up(1) if the interface is
|
||
ready to transmit and receive network traffic; it should
|
||
change to dormant(5) if the interface is waiting for
|
||
external actions (such as a serial line waiting for an
|
||
incoming connection); it should remain in the down(2) state
|
||
if and only if there is a fault that prevents it from going
|
||
to the up(1) state; it should remain in the notPresent(6)
|
||
state if the interface has missing (typically, hardware)
|
||
components."
|
||
::= { ifEntry 8 }
|
||
|
||
ifLastChange OBJECT-TYPE
|
||
SYNTAX TimeTicks
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The value of sysUpTime at the time the interface entered
|
||
its current operational state. If the current state was
|
||
entered prior to the last re-initialization of the local
|
||
network management subsystem, then this object contains a
|
||
zero value."
|
||
::= { ifEntry 9 }
|
||
|
||
ifInOctets OBJECT-TYPE
|
||
SYNTAX Counter32
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The total number of octets received on the interface,
|
||
including framing characters.
|
||
Discontinuities in the value of this counter can occur at
|
||
re-initialization of the management system, and at other
|
||
times as indicated by the value of
|
||
ifCounterDiscontinuityTime."
|
||
::= { ifEntry 10 }
|
||
|
||
ifInUcastPkts OBJECT-TYPE
|
||
SYNTAX Counter32
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The number of packets, delivered by this sub-layer to a
|
||
higher (sub-)layer, which were not addressed to a multicast
|
||
or broadcast address at this sub-layer.
|
||
Discontinuities in the value of this counter can occur at
|
||
re-initialization of the management system, and at other
|
||
times as indicated by the value of
|
||
ifCounterDiscontinuityTime."
|
||
::= { ifEntry 11 }
|
||
|
||
ifInNUcastPkts OBJECT-TYPE
|
||
SYNTAX Counter32
|
||
MAX-ACCESS read-only
|
||
STATUS deprecated
|
||
DESCRIPTION
|
||
"The number of packets, delivered by this sub-layer to a
|
||
higher (sub-)layer, which were addressed to a multicast or
|
||
broadcast address at this sub-layer.
|
||
Discontinuities in the value of this counter can occur at
|
||
re-initialization of the management system, and at other
|
||
times as indicated by the value of
|
||
ifCounterDiscontinuityTime.
|
||
This object is deprecated in favour of ifInMulticastPkts and
|
||
ifInBroadcastPkts."
|
||
::= { ifEntry 12 }
|
||
|
||
ifInDiscards OBJECT-TYPE
|
||
SYNTAX Counter32
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The number of inbound packets which were chosen to be
|
||
discarded even though no errors had been detected to prevent
|
||
their being deliverable to a higher-layer protocol. One
|
||
possible reason for discarding such a packet could be to
|
||
free up buffer space.
|
||
Discontinuities in the value of this counter can occur at
|
||
re-initialization of the management system, and at other
|
||
times as indicated by the value of
|
||
ifCounterDiscontinuityTime."
|
||
::= { ifEntry 13 }
|
||
|
||
ifInErrors OBJECT-TYPE
|
||
SYNTAX Counter32
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"For packet-oriented interfaces, the number of inbound
|
||
packets that contained errors preventing them from being
|
||
deliverable to a higher-layer protocol. For character-
|
||
oriented or fixed-length interfaces, the number of inbound
|
||
transmission units that contained errors preventing them
|
||
from being deliverable to a higher-layer protocol.
|
||
Discontinuities in the value of this counter can occur at
|
||
re-initialization of the management system, and at other
|
||
times as indicated by the value of
|
||
ifCounterDiscontinuityTime."
|
||
::= { ifEntry 14 }
|
||
|
||
ifInUnknownProtos OBJECT-TYPE
|
||
SYNTAX Counter32
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"For packet-oriented interfaces, the number of packets
|
||
received via the interface which were discarded because of
|
||
an unknown or unsupported protocol. For character-oriented
|
||
or fixed-length interfaces that support protocol
|
||
multiplexing the number of transmission units received via
|
||
the interface which were discarded because of an unknown or
|
||
unsupported protocol. For any interface that does not
|
||
support protocol multiplexing, this counter will always be
|
||
0.
|
||
Discontinuities in the value of this counter can occur at
|
||
re-initialization of the management system, and at other
|
||
times as indicated by the value of
|
||
ifCounterDiscontinuityTime."
|
||
::= { ifEntry 15 }
|
||
|
||
ifOutOctets OBJECT-TYPE
|
||
SYNTAX Counter32
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The total number of octets transmitted out of the
|
||
interface, including framing characters.
|
||
Discontinuities in the value of this counter can occur at
|
||
re-initialization of the management system, and at other
|
||
times as indicated by the value of
|
||
ifCounterDiscontinuityTime."
|
||
::= { ifEntry 16 }
|
||
|
||
ifOutUcastPkts OBJECT-TYPE
|
||
SYNTAX Counter32
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The total number of packets that higher-level protocols
|
||
requested be transmitted, and which were not addressed to a
|
||
multicast or broadcast address at this sub-layer, including
|
||
those that were discarded or not sent.
|
||
Discontinuities in the value of this counter can occur at
|
||
re-initialization of the management system, and at other
|
||
times as indicated by the value of
|
||
ifCounterDiscontinuityTime."
|
||
::= { ifEntry 17 }
|
||
|
||
ifOutNUcastPkts OBJECT-TYPE
|
||
SYNTAX Counter32
|
||
MAX-ACCESS read-only
|
||
STATUS deprecated
|
||
DESCRIPTION
|
||
"The total number of packets that higher-level protocols
|
||
requested be transmitted, and which were addressed to a
|
||
multicast or broadcast address at this sub-layer, including
|
||
those that were discarded or not sent.
|
||
Discontinuities in the value of this counter can occur at
|
||
re-initialization of the management system, and at other
|
||
times as indicated by the value of
|
||
ifCounterDiscontinuityTime.
|
||
This object is deprecated in favour of ifOutMulticastPkts
|
||
and ifOutBroadcastPkts."
|
||
::= { ifEntry 18 }
|
||
|
||
ifOutDiscards OBJECT-TYPE
|
||
SYNTAX Counter32
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The number of outbound packets which were chosen to be
|
||
discarded even though no errors had been detected to prevent
|
||
their being transmitted. One possible reason for discarding
|
||
such a packet could be to free up buffer space.
|
||
Discontinuities in the value of this counter can occur at
|
||
re-initialization of the management system, and at other
|
||
times as indicated by the value of
|
||
ifCounterDiscontinuityTime."
|
||
::= { ifEntry 19 }
|
||
|
||
ifOutErrors OBJECT-TYPE
|
||
SYNTAX Counter32
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"For packet-oriented interfaces, the number of outbound
|
||
packets that could not be transmitted because of errors.
|
||
For character-oriented or fixed-length interfaces, the
|
||
number of outbound transmission units that could not be
|
||
transmitted because of errors.
|
||
Discontinuities in the value of this counter can occur at
|
||
re-initialization of the management system, and at other
|
||
times as indicated by the value of
|
||
ifCounterDiscontinuityTime."
|
||
::= { ifEntry 20 }
|
||
|
||
ifOutQLen OBJECT-TYPE
|
||
SYNTAX Gauge32
|
||
MAX-ACCESS read-only
|
||
STATUS deprecated
|
||
DESCRIPTION
|
||
"The length of the output packet queue (in packets)."
|
||
::= { ifEntry 21 }
|
||
|
||
ifSpecific OBJECT-TYPE
|
||
SYNTAX OBJECT IDENTIFIER
|
||
MAX-ACCESS read-only
|
||
STATUS deprecated
|
||
DESCRIPTION
|
||
"A reference to MIB definitions specific to the particular
|
||
media being used to realize the interface. It is
|
||
recommended that this value point to an instance of a MIB
|
||
object in the media-specific MIB, i.e., that this object
|
||
have the semantics associated with the InstancePointer
|
||
textual convention defined in RFC 2579. In fact, it is
|
||
recommended that the media-specific MIB specify what value
|
||
ifSpecific should/can take for values of ifType. If no MIB
|
||
definitions specific to the particular media are available,
|
||
the value should be set to the OBJECT IDENTIFIER { 0 0 }."
|
||
::= { ifEntry 22 }
|
||
|
||
ipForwarding OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
forwarding(1), -- acting as a gateway
|
||
not-forwarding(2) -- NOT acting as a gateway
|
||
}
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"The indication of whether this entity is acting
|
||
as an IP gateway in respect to the forwarding of
|
||
datagrams received by, but not addressed to, this
|
||
entity. IP gateways forward datagrams. IP hosts
|
||
do not (except those source-routed via the host).
|
||
Note that for some managed nodes, this object may
|
||
take on only a subset of the values possible.
|
||
Accordingly, it is appropriate for an agent to
|
||
return a `badValue' response if a management
|
||
station attempts to change this object to an
|
||
inappropriate value."
|
||
::= { ip 1 }
|
||
|
||
ipDefaultTTL OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"The default value inserted into the Time-To-Live
|
||
field of the IP header of datagrams originated at
|
||
this entity, whenever a TTL value is not supplied
|
||
by the transport layer protocol."
|
||
::= { ip 2 }
|
||
|
||
ipInReceives OBJECT-TYPE
|
||
SYNTAX Counter
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"The total number of input datagrams received from
|
||
interfaces, including those received in error."
|
||
::= { ip 3 }
|
||
|
||
ipInHdrErrors OBJECT-TYPE
|
||
SYNTAX Counter
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"The number of input datagrams discarded due to
|
||
errors in their IP headers, including bad
|
||
checksums, version number mismatch, other format
|
||
errors, time-to-live exceeded, errors discovered
|
||
in processing their IP options, etc."
|
||
::= { ip 4 }
|
||
|
||
ipInAddrErrors OBJECT-TYPE
|
||
SYNTAX Counter
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"The number of input datagrams discarded because
|
||
the IP address in their IP header's destination
|
||
field was not a valid address to be received at
|
||
this entity. This count includes invalid
|
||
addresses (e.g., 0.0.0.0) and addresses of
|
||
unsupported Classes (e.g., Class E). For entities
|
||
which are not IP Gateways and therefore do not
|
||
forward datagrams, this counter includes datagrams
|
||
discarded because the destination address was not
|
||
a local address."
|
||
::= { ip 5 }
|
||
|
||
ipForwDatagrams OBJECT-TYPE
|
||
SYNTAX Counter
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"The number of input datagrams for which this
|
||
entity was not their final IP destination, as a
|
||
result of which an attempt was made to find a
|
||
route to forward them to that final destination.
|
||
In entities which do not act as IP Gateways, this
|
||
counter will include only those packets which were
|
||
Source-Routed via this entity, and the Source-
|
||
Route option processing was successful."
|
||
::= { ip 6 }
|
||
|
||
ipInUnknownProtos OBJECT-TYPE
|
||
SYNTAX Counter
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"The number of locally-addressed datagrams
|
||
received successfully but discarded because of an
|
||
unknown or unsupported protocol."
|
||
::= { ip 7 }
|
||
|
||
ipInDiscards OBJECT-TYPE
|
||
SYNTAX Counter
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"The number of input IP datagrams for which no
|
||
problems were encountered to prevent their
|
||
continued processing, but which were discarded
|
||
(e.g., for lack of buffer space). Note that this
|
||
counter does not include any datagrams discarded
|
||
while awaiting re-assembly."
|
||
::= { ip 8 }
|
||
|
||
ipInDelivers OBJECT-TYPE
|
||
SYNTAX Counter
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"The total number of input datagrams successfully
|
||
delivered to IP user-protocols (including ICMP)."
|
||
::= { ip 9 }
|
||
|
||
ipOutRequests OBJECT-TYPE
|
||
SYNTAX Counter
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"The total number of IP datagrams which local IP
|
||
user-protocols (including ICMP) supplied to IP in
|
||
requests for transmission. Note that this counter
|
||
does not include any datagrams counted in
|
||
ipForwDatagrams."
|
||
::= { ip 10 }
|
||
|
||
ipOutDiscards OBJECT-TYPE
|
||
SYNTAX Counter
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"The number of output IP datagrams for which no
|
||
problem was encountered to prevent their
|
||
transmission to their destination, but which were
|
||
discarded (e.g., for lack of buffer space). Note
|
||
that this counter would include datagrams counted
|
||
in ipForwDatagrams if any such packets met this
|
||
(discretionary) discard criterion."
|
||
::= { ip 11 }
|
||
|
||
ipOutNoRoutes OBJECT-TYPE
|
||
SYNTAX Counter
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"The number of IP datagrams discarded because no
|
||
route could be found to transmit them to their
|
||
destination. Note that this counter includes any
|
||
packets counted in ipForwDatagrams which meet this
|
||
`no-route' criterion. Note that this includes any
|
||
datagarms which a host cannot route because all of
|
||
its default gateways are down."
|
||
::= { ip 12 }
|
||
|
||
ipReasmTimeout OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"The maximum number of seconds which received
|
||
fragments are held while they are awaiting
|
||
reassembly at this entity."
|
||
::= { ip 13 }
|
||
|
||
ipReasmReqds OBJECT-TYPE
|
||
SYNTAX Counter
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"The number of IP fragments received which needed
|
||
to be reassembled at this entity."
|
||
::= { ip 14 }
|
||
|
||
ipReasmOKs OBJECT-TYPE
|
||
SYNTAX Counter
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"The number of IP datagrams successfully re-
|
||
assembled."
|
||
::= { ip 15 }
|
||
|
||
ipReasmFails OBJECT-TYPE
|
||
SYNTAX Counter
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"The number of failures detected by the IP re-
|
||
assembly algorithm (for whatever reason: timed
|
||
out, errors, etc). Note that this is not
|
||
necessarily a count of discarded IP fragments
|
||
since some algorithms (notably the algorithm in
|
||
RFC 815) can lose track of the number of fragments
|
||
by combining them as they are received."
|
||
::= { ip 16 }
|
||
|
||
ipFragOKs OBJECT-TYPE
|
||
SYNTAX Counter
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"The number of IP datagrams that have been
|
||
successfully fragmented at this entity."
|
||
::= { ip 17 }
|
||
|
||
ipFragFails OBJECT-TYPE
|
||
SYNTAX Counter
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"The number of IP datagrams that have been
|
||
discarded because they needed to be fragmented at
|
||
this entity but could not be, e.g., because their
|
||
Don't Fragment flag was set."
|
||
::= { ip 18 }
|
||
|
||
ipFragCreates OBJECT-TYPE
|
||
SYNTAX Counter
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"The number of IP datagram fragments that have
|
||
been generated as a result of fragmentation at
|
||
this entity."
|
||
::= { ip 19 }
|
||
|
||
ipAdEntAddr OBJECT-TYPE
|
||
SYNTAX IpAddress
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"The IP address to which this entry's addressing
|
||
information pertains."
|
||
::= { ipAddrEntry 1 }
|
||
|
||
ipAdEntIfIndex OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"The index value which uniquely identifies the
|
||
interface to which this entry is applicable. The
|
||
interface identified by a particular value of this
|
||
index is the same interface as identified by the
|
||
same value of ifIndex."
|
||
::= { ipAddrEntry 2 }
|
||
|
||
ipAdEntNetMask OBJECT-TYPE
|
||
SYNTAX IpAddress
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"The subnet mask associated with the IP address of
|
||
this entry. The value of the mask is an IP
|
||
address with all the network bits set to 1 and all
|
||
the hosts bits set to 0."
|
||
::= { ipAddrEntry 3 }
|
||
|
||
ipAdEntBcastAddr OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"The value of the least-significant bit in the IP
|
||
broadcast address used for sending datagrams on
|
||
the (logical) interface associated with the IP
|
||
address of this entry. For example, when the
|
||
Internet standard all-ones broadcast address is
|
||
used, the value will be 1. This value applies to
|
||
both the subnet and network broadcasts addresses
|
||
used by the entity on this (logical) interface."
|
||
::= { ipAddrEntry 4 }
|
||
|
||
ipRouteDest OBJECT-TYPE
|
||
SYNTAX IpAddress
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"The destination IP address of this route. An
|
||
entry with a value of 0.0.0.0 is considered a
|
||
default route. Multiple routes to a single
|
||
destination can appear in the table, but access to
|
||
such multiple entries is dependent on the table-
|
||
access mechanisms defined by the network
|
||
management protocol in use."
|
||
::= { ipRouteEntry 1 }
|
||
|
||
ipRouteIfIndex OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"The index value which uniquely identifies the
|
||
local interface through which the next hop of this
|
||
route should be reached. The interface identified
|
||
by a particular value of this index is the same
|
||
interface as identified by the same value of
|
||
ifIndex."
|
||
::= { ipRouteEntry 2 }
|
||
|
||
ipRouteMetric1 OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"The primary routing metric for this route. The
|
||
semantics of this metric are determined by the
|
||
routing-protocol specified in the route's
|
||
ipRouteProto value. If this metric is not used,
|
||
its value should be set to -1."
|
||
::= { ipRouteEntry 3 }
|
||
|
||
ipRouteNextHop OBJECT-TYPE
|
||
SYNTAX IpAddress
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"The IP address of the next hop of this route.
|
||
(In the case of a route bound to an interface
|
||
which is realized via a broadcast media, the value
|
||
of this field is the agent's IP address on that
|
||
interface.)"
|
||
::= { ipRouteEntry 7 }
|
||
|
||
ipRouteType OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
other(1), -- none of the following
|
||
invalid(2), -- an invalidated route
|
||
-- route to directly
|
||
direct(3), -- connected (sub-)network
|
||
-- route to a non-local
|
||
indirect(4) -- host/network/sub-network
|
||
}
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"The type of route. Note that the values
|
||
direct(3) and indirect(4) refer to the notion of
|
||
direct and indirect routing in the IP
|
||
architecture.
|
||
Setting this object to the value invalid(2) has
|
||
the effect of invalidating the corresponding entry
|
||
in the ipRouteTable object. That is, it
|
||
effectively dissasociates the destination
|
||
identified with said entry from the route
|
||
identified with said entry. It is an
|
||
implementation-specific matter as to whether the
|
||
agent removes an invalidated entry from the table.
|
||
Accordingly, management stations must be prepared
|
||
to receive tabular information from agents that
|
||
corresponds to entries not currently in use.
|
||
Proper interpretation of such entries requires
|
||
examination of the relevant ipRouteType object."
|
||
::= { ipRouteEntry 8 }
|
||
|
||
ipRouteProto OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
other(1), -- none of the following
|
||
-- non-protocol information,
|
||
-- e.g., manually configured
|
||
local(2), -- entries
|
||
-- set via a network
|
||
netmgmt(3), -- management protocol
|
||
-- obtained via ICMP,
|
||
icmp(4), -- e.g., Redirect
|
||
-- the remaining values are
|
||
-- all gateway routing
|
||
-- protocols
|
||
egp(5),
|
||
ggp(6),
|
||
hello(7),
|
||
rip(8),
|
||
is-is(9),
|
||
es-is(10),
|
||
ciscoIgrp(11),
|
||
bbnSpfIgp(12),
|
||
ospf(13),
|
||
bgp(14)
|
||
}
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"The routing mechanism via which this route was
|
||
learned. Inclusion of values for gateway routing
|
||
protocols is not intended to imply that hosts
|
||
should support those protocols."
|
||
::= { ipRouteEntry 9 }
|
||
|
||
ipRouteMask OBJECT-TYPE
|
||
SYNTAX IpAddress
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Indicate the mask to be logical-ANDed with the
|
||
destination address before being compared to the
|
||
value in the ipRouteDest field. For those systems
|
||
that do not support arbitrary subnet masks, an
|
||
agent constructs the value of the ipRouteMask by
|
||
determining whether the value of the correspondent
|
||
ipRouteDest field belong to a class-A, B, or C
|
||
network, and then using one of:
|
||
mask network
|
||
255.0.0.0 class-A
|
||
255.255.0.0 class-B
|
||
255.255.255.0 class-C
|
||
If the value of the ipRouteDest is 0.0.0.0 (a
|
||
default route), then the mask value is also
|
||
0.0.0.0. It should be noted that all IP routing
|
||
subsystems implicitly use this mechanism."
|
||
::= { ipRouteEntry 11 }
|
||
|
||
ipRouteInfo OBJECT-TYPE
|
||
SYNTAX OBJECT IDENTIFIER
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"A reference to MIB definitions specific to the
|
||
particular routing protocol which is responsible
|
||
for this route, as determined by the value
|
||
specified in the route's ipRouteProto value. If
|
||
this information is not present, its value should
|
||
be set to the OBJECT IDENTIFIER { 0 0 }, which is
|
||
a syntatically valid object identifier, and any
|
||
conformant implementation of ASN.1 and BER must be
|
||
able to generate and recognize this value."
|
||
::= { ipRouteEntry 13 }
|
||
|
||
ipNetToMediaIfIndex OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"The interface on which this entry's equivalence
|
||
is effective. The interface identified by a
|
||
particular value of this index is the same
|
||
interface as identified by the same value of
|
||
ifIndex."
|
||
::= { ipNetToMediaEntry 1 }
|
||
|
||
ipNetToMediaPhysAddress OBJECT-TYPE
|
||
SYNTAX PhysAddress
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"The media-dependent `physical' address."
|
||
::= { ipNetToMediaEntry 2 }
|
||
|
||
ipNetToMediaNetAddress OBJECT-TYPE
|
||
SYNTAX IpAddress
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"The IpAddress corresponding to the media-
|
||
dependent `physical' address."
|
||
::= { ipNetToMediaEntry 3 }
|
||
|
||
ipNetToMediaType OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
other(1), -- none of the following
|
||
invalid(2), -- an invalidated mapping
|
||
dynamic(3),
|
||
static(4)
|
||
}
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"The type of mapping.
|
||
Setting this object to the value invalid(2) has
|
||
the effect of invalidating the corresponding entry
|
||
in the ipNetToMediaTable. That is, it effectively
|
||
dissasociates the interface identified with said
|
||
entry from the mapping identified with said entry.
|
||
It is an implementation-specific matter as to
|
||
whether the agent removes an invalidated entry
|
||
from the table. Accordingly, management stations
|
||
must be prepared to receive tabular information
|
||
from agents that corresponds to entries not
|
||
currently in use. Proper interpretation of such
|
||
entries requires examination of the relevant
|
||
ipNetToMediaType object."
|
||
::= { ipNetToMediaEntry 4 }
|
||
|
||
ipRoutingDiscards OBJECT-TYPE
|
||
SYNTAX Counter
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"The number of routing entries which were chosen
|
||
to be discarded even though they are valid. One
|
||
possible reason for discarding such an entry could
|
||
be to free-up buffer space for other routing
|
||
entries."
|
||
::= { ip 23 }
|
||
|
||
snmpInPkts OBJECT-TYPE
|
||
SYNTAX Counter
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"The total number of Messages delivered to the
|
||
SNMP entity from the transport service."
|
||
::= { snmp 1 }
|
||
|
||
snmpOutPkts OBJECT-TYPE
|
||
SYNTAX Counter
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"The total number of SNMP Messages which were
|
||
passed from the SNMP protocol entity to the
|
||
transport service."
|
||
::= { snmp 2 }
|
||
|
||
snmpInBadVersions OBJECT-TYPE
|
||
SYNTAX Counter
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"The total number of SNMP Messages which were
|
||
delivered to the SNMP protocol entity and were for
|
||
an unsupported SNMP version."
|
||
::= { snmp 3 }
|
||
|
||
snmpInBadCommunityNames OBJECT-TYPE
|
||
SYNTAX Counter
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"The total number of SNMP Messages delivered to
|
||
the SNMP protocol entity which used a SNMP
|
||
community name not known to said entity."
|
||
::= { snmp 4 }
|
||
|
||
snmpInBadCommunityUses OBJECT-TYPE
|
||
SYNTAX Counter
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"The total number of SNMP Messages delivered to
|
||
the SNMP protocol entity which represented an SNMP
|
||
operation which was not allowed by the SNMP
|
||
community named in the Message."
|
||
::= { snmp 5 }
|
||
|
||
snmpInASNParseErrs OBJECT-TYPE
|
||
SYNTAX Counter
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"The total number of ASN.1 or BER errors
|
||
encountered by the SNMP protocol entity when
|
||
decoding received SNMP Messages."
|
||
::= { snmp 6 }
|
||
|
||
snmpInTooBigs OBJECT-TYPE
|
||
SYNTAX Counter
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"The total number of SNMP PDUs which were
|
||
delivered to the SNMP protocol entity and for
|
||
which the value of the error-status field is
|
||
`tooBig'."
|
||
::= { snmp 8 }
|
||
|
||
snmpInNoSuchNames OBJECT-TYPE
|
||
SYNTAX Counter
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"The total number of SNMP PDUs which were
|
||
delivered to the SNMP protocol entity and for
|
||
which the value of the error-status field is
|
||
`noSuchName'."
|
||
::= { snmp 9 }
|
||
|
||
snmpInBadValues OBJECT-TYPE
|
||
SYNTAX Counter
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"The total number of SNMP PDUs which were
|
||
delivered to the SNMP protocol entity and for
|
||
which the value of the error-status field is
|
||
`badValue'."
|
||
::= { snmp 10 }
|
||
|
||
snmpInReadOnlys OBJECT-TYPE
|
||
SYNTAX Counter
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"The total number valid SNMP PDUs which were
|
||
delivered to the SNMP protocol entity and for
|
||
which the value of the error-status field is
|
||
`readOnly'. It should be noted that it is a
|
||
protocol error to generate an SNMP PDU which
|
||
contains the value `readOnly' in the error-status
|
||
field, as such this object is provided as a means
|
||
of detecting incorrect implementations of the
|
||
SNMP."
|
||
::= { snmp 11 }
|
||
|
||
snmpInGenErrs OBJECT-TYPE
|
||
SYNTAX Counter
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"The total number of SNMP PDUs which were
|
||
delivered to the SNMP protocol entity and for
|
||
which the value of the error-status field is
|
||
`genErr'."
|
||
::= { snmp 12 }
|
||
|
||
snmpInTotalReqVars OBJECT-TYPE
|
||
SYNTAX Counter
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"The total number of MIB objects which have been
|
||
retrieved successfully by the SNMP protocol entity
|
||
as the result of receiving valid SNMP Get-Request
|
||
and Get-Next PDUs."
|
||
::= { snmp 13 }
|
||
|
||
snmpInTotalSetVars OBJECT-TYPE
|
||
SYNTAX Counter
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"The total number of MIB objects which have been
|
||
altered successfully by the SNMP protocol entity
|
||
as the result of receiving valid SNMP Set-Request
|
||
PDUs."
|
||
::= { snmp 14 }
|
||
|
||
snmpInGetRequests OBJECT-TYPE
|
||
SYNTAX Counter
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"The total number of SNMP Get-Request PDUs which
|
||
have been accepted and processed by the SNMP
|
||
protocol entity."
|
||
::= { snmp 15 }
|
||
|
||
snmpInGetNexts OBJECT-TYPE
|
||
SYNTAX Counter
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"The total number of SNMP Get-Next PDUs which have
|
||
been accepted and processed by the SNMP protocol
|
||
entity."
|
||
::= { snmp 16 }
|
||
|
||
snmpInSetRequests OBJECT-TYPE
|
||
SYNTAX Counter
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"The total number of SNMP Set-Request PDUs which
|
||
have been accepted and processed by the SNMP
|
||
protocol entity."
|
||
::= { snmp 17 }
|
||
|
||
snmpInGetResponses OBJECT-TYPE
|
||
SYNTAX Counter
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"The total number of SNMP Get-Response PDUs which
|
||
have been accepted and processed by the SNMP
|
||
protocol entity."
|
||
::= { snmp 18 }
|
||
|
||
snmpInTraps OBJECT-TYPE
|
||
SYNTAX Counter
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"The total number of SNMP Trap PDUs which have
|
||
been accepted and processed by the SNMP protocol
|
||
entity."
|
||
::= { snmp 19 }
|
||
|
||
snmpOutTooBigs OBJECT-TYPE
|
||
SYNTAX Counter
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"The total number of SNMP PDUs which were
|
||
generated by the SNMP protocol entity and for
|
||
which the value of the error-status field is
|
||
`tooBig.'"
|
||
::= { snmp 20 }
|
||
|
||
snmpOutNoSuchNames OBJECT-TYPE
|
||
SYNTAX Counter
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"The total number of SNMP PDUs which were
|
||
generated by the SNMP protocol entity and for
|
||
which the value of the error-status is
|
||
`noSuchName'."
|
||
::= { snmp 21 }
|
||
|
||
snmpOutBadValues OBJECT-TYPE
|
||
SYNTAX Counter
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"The total number of SNMP PDUs which were
|
||
generated by the SNMP protocol entity and for
|
||
which the value of the error-status field is
|
||
`badValue'."
|
||
::= { snmp 22 }
|
||
|
||
snmpOutGenErrs OBJECT-TYPE
|
||
SYNTAX Counter
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"The total number of SNMP PDUs which were
|
||
generated by the SNMP protocol entity and for
|
||
which the value of the error-status field is
|
||
`genErr'."
|
||
::= { snmp 24 }
|
||
|
||
snmpOutGetRequests OBJECT-TYPE
|
||
SYNTAX Counter
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"The total number of SNMP Get-Request PDUs which
|
||
have been generated by the SNMP protocol entity."
|
||
::= { snmp 25 }
|
||
|
||
snmpOutGetNexts OBJECT-TYPE
|
||
SYNTAX Counter
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"The total number of SNMP Get-Next PDUs which have
|
||
been generated by the SNMP protocol entity."
|
||
::= { snmp 26 }
|
||
|
||
snmpOutSetRequests OBJECT-TYPE
|
||
SYNTAX Counter
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"The total number of SNMP Set-Request PDUs which
|
||
have been generated by the SNMP protocol entity."
|
||
::= { snmp 27 }
|
||
|
||
snmpOutGetResponses OBJECT-TYPE
|
||
SYNTAX Counter
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"The total number of SNMP Get-Response PDUs which
|
||
have been generated by the SNMP protocol entity."
|
||
::= { snmp 28 }
|
||
|
||
snmpOutTraps OBJECT-TYPE
|
||
SYNTAX Counter
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"The total number of SNMP Trap PDUs which have
|
||
been generated by the SNMP protocol entity."
|
||
::= { snmp 29 }
|
||
|
||
snmpEnableAuthenTraps OBJECT-TYPE
|
||
SYNTAX INTEGER { enabled(1), disabled(2) }
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Indicates whether the SNMP agent process is
|
||
permitted to generate authentication-failure
|
||
traps. The value of this object overrides any
|
||
configuration information; as such, it provides a
|
||
means whereby all authentication-failure traps may
|
||
be disabled.
|
||
Note that it is strongly recommended that this
|
||
object be stored in non-volatile memory so that it
|
||
remains constant between re-initializations of the
|
||
network management system."
|
||
::= { snmp 30 }
|
||
|
||
snmpSilentDrops OBJECT-TYPE
|
||
SYNTAX Counter32
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The total number of Confirmed Class PDUs (such as
|
||
GetRequest-PDUs, GetNextRequest-PDUs,
|
||
GetBulkRequest-PDUs, SetRequest-PDUs, and
|
||
InformRequest-PDUs) delivered to the SNMP entity which
|
||
were silently dropped because the size of a reply
|
||
containing an alternate Response Class PDU (such as a
|
||
Response-PDU) with an empty variable-bindings field
|
||
was greater than either a local constraint or the
|
||
maximum message size associated with the originator of
|
||
the request."
|
||
::= { snmp 31 }
|
||
|
||
snmpProxyDrops OBJECT-TYPE
|
||
SYNTAX Counter32
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The total number of Confirmed Class PDUs
|
||
(such as GetRequest-PDUs, GetNextRequest-PDUs,
|
||
GetBulkRequest-PDUs, SetRequest-PDUs, and
|
||
InformRequest-PDUs) delivered to the SNMP entity which
|
||
were silently dropped because the transmission of
|
||
the (possibly translated) message to a proxy target
|
||
failed in a manner (other than a time-out) such that
|
||
no Response Class PDU (such as a Response-PDU) could
|
||
be returned."
|
||
::= { snmp 32 }
|
||
|
||
hrSystemUptime OBJECT-TYPE
|
||
SYNTAX TimeTicks
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The amount of time since this host was last
|
||
initialized. Note that this is different from
|
||
sysUpTime in the SNMPv2-MIB [RFC1907] because
|
||
sysUpTime is the uptime of the network management
|
||
portion of the system."
|
||
::= { hrSystem 1 }
|
||
|
||
hrSystemDate OBJECT-TYPE
|
||
SYNTAX DateAndTime
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The host's notion of the local date and time of day."
|
||
::= { hrSystem 2 }
|
||
|
||
hrSystemInitialLoadDevice OBJECT-TYPE
|
||
SYNTAX Integer32 (1..2147483647)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The index of the hrDeviceEntry for the device from
|
||
which this host is configured to load its initial
|
||
operating system configuration (i.e., which operating
|
||
system code and/or boot parameters).
|
||
Note that writing to this object just changes the
|
||
configuration that will be used the next time the
|
||
operating system is loaded and does not actually cause
|
||
the reload to occur."
|
||
::= { hrSystem 3 }
|
||
|
||
hrSystemInitialLoadParameters OBJECT-TYPE
|
||
SYNTAX InternationalDisplayString (SIZE (0..128))
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"This object contains the parameters (e.g. a pathname
|
||
and parameter) supplied to the load device when
|
||
requesting the initial operating system configuration
|
||
from that device.
|
||
Note that writing to this object just changes the
|
||
configuration that will be used the next time the
|
||
operating system is loaded and does not actually cause
|
||
the reload to occur."
|
||
::= { hrSystem 4 }
|
||
|
||
hrSystemNumUsers OBJECT-TYPE
|
||
SYNTAX Gauge32
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The number of user sessions for which this host is
|
||
storing state information. A session is a collection
|
||
of processes requiring a single act of user
|
||
authentication and possibly subject to collective job
|
||
control."
|
||
::= { hrSystem 5 }
|
||
|
||
hrSystemProcesses OBJECT-TYPE
|
||
SYNTAX Gauge32
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The number of process contexts currently loaded or
|
||
running on this system."
|
||
::= { hrSystem 6 }
|
||
|
||
hrSystemMaxProcesses OBJECT-TYPE
|
||
SYNTAX Integer32 (0..2147483647)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The maximum number of process contexts this system
|
||
can support. If there is no fixed maximum, the value
|
||
should be zero. On systems that have a fixed maximum,
|
||
this object can help diagnose failures that occur when
|
||
this maximum is reached."
|
||
::= { hrSystem 7 }
|
||
|
||
hrMemorySize OBJECT-TYPE
|
||
SYNTAX KBytes
|
||
UNITS "KBytes"
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The amount of physical read-write main memory,
|
||
typically RAM, contained by the host."
|
||
::= { hrStorage 2 }
|
||
|
||
hrStorageIndex OBJECT-TYPE
|
||
SYNTAX Integer32 (1..2147483647)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"A unique value for each logical storage area
|
||
contained by the host."
|
||
::= { hrStorageEntry 1 }
|
||
|
||
hrStorageType OBJECT-TYPE
|
||
SYNTAX AutonomousType
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The type of storage represented by this entry."
|
||
::= { hrStorageEntry 2 }
|
||
|
||
hrStorageDescr OBJECT-TYPE
|
||
SYNTAX DisplayString
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"A description of the type and instance of the storage
|
||
described by this entry."
|
||
::= { hrStorageEntry 3 }
|
||
|
||
hrStorageAllocationUnits OBJECT-TYPE
|
||
SYNTAX Integer32 (1..2147483647)
|
||
UNITS "Bytes"
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The size, in bytes, of the data objects allocated
|
||
from this pool. If this entry is monitoring sectors,
|
||
blocks, buffers, or packets, for example, this number
|
||
will commonly be greater than one. Otherwise this
|
||
number will typically be one."
|
||
::= { hrStorageEntry 4 }
|
||
|
||
hrStorageSize OBJECT-TYPE
|
||
SYNTAX Integer32 (0..2147483647)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The size of the storage represented by this entry, in
|
||
units of hrStorageAllocationUnits. This object is
|
||
writable to allow remote configuration of the size of
|
||
the storage area in those cases where such an
|
||
operation makes sense and is possible on the
|
||
underlying system. For example, the amount of main
|
||
memory allocated to a buffer pool might be modified or
|
||
the amount of disk space allocated to virtual memory
|
||
might be modified."
|
||
::= { hrStorageEntry 5 }
|
||
|
||
hrStorageUsed OBJECT-TYPE
|
||
SYNTAX Integer32 (0..2147483647)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The amount of the storage represented by this entry
|
||
that is allocated, in units of
|
||
hrStorageAllocationUnits."
|
||
::= { hrStorageEntry 6 }
|
||
|
||
hrDeviceIndex OBJECT-TYPE
|
||
SYNTAX Integer32 (1..2147483647)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"A unique value for each device contained by the host.
|
||
The value for each device must remain constant at
|
||
least from one re-initialization of the agent to the
|
||
next re-initialization."
|
||
::= { hrDeviceEntry 1 }
|
||
|
||
hrDeviceType OBJECT-TYPE
|
||
SYNTAX AutonomousType
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"An indication of the type of device.
|
||
If this value is
|
||
`hrDeviceProcessor { hrDeviceTypes 3 }' then an entry
|
||
exists in the hrProcessorTable which corresponds to
|
||
this device.
|
||
If this value is
|
||
`hrDeviceNetwork { hrDeviceTypes 4 }', then an entry
|
||
exists in the hrNetworkTable which corresponds to this
|
||
device.
|
||
If this value is
|
||
`hrDevicePrinter { hrDeviceTypes 5 }', then an entry
|
||
exists in the hrPrinterTable which corresponds to this
|
||
device.
|
||
If this value is
|
||
`hrDeviceDiskStorage { hrDeviceTypes 6 }', then an
|
||
entry exists in the hrDiskStorageTable which
|
||
corresponds to this device."
|
||
::= { hrDeviceEntry 2 }
|
||
|
||
hrDeviceDescr OBJECT-TYPE
|
||
SYNTAX DisplayString (SIZE (0..64))
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"A textual description of this device, including the
|
||
device's manufacturer and revision, and optionally,
|
||
its serial number."
|
||
::= { hrDeviceEntry 3 }
|
||
|
||
hrDeviceID OBJECT-TYPE
|
||
SYNTAX ProductID
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The product ID for this device."
|
||
::= { hrDeviceEntry 4 }
|
||
|
||
hrDeviceStatus OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
unknown(1),
|
||
running(2),
|
||
warning(3),
|
||
testing(4),
|
||
down(5)
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The current operational state of the device described
|
||
by this row of the table. A value unknown(1)
|
||
indicates that the current state of the device is
|
||
unknown. running(2) indicates that the device is up
|
||
and running and that no unusual error conditions are
|
||
known. The warning(3) state indicates that agent has
|
||
been informed of an unusual error condition by the
|
||
operational software (e.g., a disk device driver) but
|
||
that the device is still 'operational'. An example
|
||
would be a high number of soft errors on a disk. A
|
||
value of testing(4), indicates that the device is not
|
||
available for use because it is in the testing state.
|
||
The state of down(5) is used only when the agent has
|
||
been informed that the device is not available for any
|
||
use."
|
||
::= { hrDeviceEntry 5 }
|
||
|
||
hrDeviceErrors OBJECT-TYPE
|
||
SYNTAX Counter32
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The number of errors detected on this device. It
|
||
should be noted that as this object has a SYNTAX of
|
||
Counter32, that it does not have a defined initial
|
||
value. However, it is recommended that this object be
|
||
initialized to zero, even though management stations
|
||
must not depend on such an initialization."
|
||
::= { hrDeviceEntry 6 }
|
||
|
||
hrPrinterStatus OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
other(1),
|
||
unknown(2),
|
||
idle(3),
|
||
printing(4),
|
||
warmup(5)
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The current status of this printer device."
|
||
::= { hrPrinterEntry 1 }
|
||
|
||
hrPrinterDetectedErrorState OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"This object represents any error conditions detected
|
||
by the printer. The error conditions are encoded as
|
||
bits in an octet string, with the following
|
||
definitions:
|
||
Condition Bit #
|
||
lowPaper 0
|
||
noPaper 1
|
||
lowToner 2
|
||
noToner 3
|
||
doorOpen 4
|
||
jammed 5
|
||
offline 6
|
||
serviceRequested 7
|
||
inputTrayMissing 8
|
||
outputTrayMissing 9
|
||
markerSupplyMissing 10
|
||
outputNearFull 11
|
||
outputFull 12
|
||
inputTrayEmpty 13
|
||
overduePreventMaint 14
|
||
Bits are numbered starting with the most significant
|
||
bit of the first byte being bit 0, the least
|
||
significant bit of the first byte being bit 7, the
|
||
most significant bit of the second byte being bit 8,
|
||
and so on. A one bit encodes that the condition was
|
||
detected, while a zero bit encodes that the condition
|
||
was not detected.
|
||
This object is useful for alerting an operator to
|
||
specific warning or error conditions that may occur,
|
||
especially those requiring human intervention."
|
||
::= { hrPrinterEntry 2 }
|
||
|
||
ifTableLastChange OBJECT-TYPE
|
||
SYNTAX TimeTicks
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The value of sysUpTime at the time of the last creation or
|
||
deletion of an entry in the ifTable. If the number of
|
||
entries has been unchanged since the last re-initialization
|
||
of the local network management subsystem, then this object
|
||
contains a zero value."
|
||
::= { ifMIBObjects 5 }
|
||
|
||
prtGeneralConfigChanges OBJECT-TYPE
|
||
SYNTAX Counter32
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Counts configuration changes within the printer. A
|
||
configuration change is defined to be an action that results in
|
||
a change to any MIB object other than those that reflect status
|
||
or level, or those that act as counters or gauges. In addition,
|
||
any action that results in a row being added or deleted from
|
||
any table in the Printer MIB is considered a configuration
|
||
change. Such changes will often affect the capability of the
|
||
printer to service certain types of print jobs. Management
|
||
applications may cache infrequently changed configuration
|
||
information about sub units within the printer. This object
|
||
should be incremented whenever the agent wishes to notify
|
||
management applications that any cached configuration
|
||
information for this device is to be considered 'stale'. At
|
||
this point, the management application should flush any
|
||
configuration information cached about this device and fetch
|
||
new configuration information.
|
||
The following are examples of actions that would cause the
|
||
prtGeneralConfigChanges object to be incremented:
|
||
- Adding an output bin
|
||
- Changing the media in a sensing input tray
|
||
- Changing the value of prtInputMediaType
|
||
Note that the prtGeneralConfigChanges counter would not be
|
||
incremented when an input tray is temporarily removed to load
|
||
additional paper or when the level of an input device changes.
|
||
NOTE: The above description has been modified from RFC 1759
|
||
for clarification."
|
||
::= { prtGeneralEntry 1 }
|
||
|
||
prtGeneralCurrentLocalization OBJECT-TYPE
|
||
SYNTAX Integer32 (1..65535)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The value of the prtLocalizationIndex corresponding to the
|
||
current language, country, and character set to be used for
|
||
localized string values that are identified as being dependent
|
||
on the value of this object. Note that this object does not
|
||
apply to localized strings in the prtConsole group or to any
|
||
object that is not explicitly identified as being localized
|
||
according to prtGeneralCurrentLocalization. When an object's
|
||
'charset' is controlled by the value of
|
||
prtGeneralCurrentLocalization, it MUST specify
|
||
PrtLocalizedDescriptionStringTC as its syntax.
|
||
NOTE: The above description has been modified from RFC 1759
|
||
for clarification."
|
||
::= { prtGeneralEntry 2 }
|
||
|
||
prtGeneralReset OBJECT-TYPE
|
||
-- NOTE: In RFC 1759, the enumeration values were implicitly defined
|
||
-- by this object.
|
||
SYNTAX PrtGeneralResetTC
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Setting this value to 'powerCycleReset', 'resetToNVRAM', or
|
||
'resetToFactoryDefaults' will result in the resetting of the
|
||
printer. When read, this object will always have the value
|
||
'notResetting(3)', and a SET of the value 'notResetting' shall
|
||
have no effect on the printer. Some of the defined values are
|
||
optional. However, every implementation must support at least
|
||
the values 'notResetting' and 'resetToNVRAM'."
|
||
::= { prtGeneralEntry 3 }
|
||
|
||
prtGeneralCurrentOperator OBJECT-TYPE
|
||
SYNTAX OCTET STRING (SIZE(0..127))
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The name of the person who is responsible for operating
|
||
this printer. It is suggested that this string include
|
||
information that would enable other humans to reach the
|
||
operator, such as a phone number. As a convention to
|
||
facilitate automatic notification of the operator by the
|
||
agent or network management station, the phone number,
|
||
fax number or email address should be indicated by the
|
||
URL schemes 'tel:', 'fax:' and 'mailto:', respectively.
|
||
If either the phone, fax, or email information is not
|
||
available, then a line should not be included for this
|
||
information.
|
||
NOTE: For interoperability purposes, it is advisable to
|
||
use email addresses formatted according to [RFC2822]
|
||
requirements.
|
||
NOTE: The above description has been modified from RFC 1759
|
||
for clarification."
|
||
::= { prtGeneralEntry 4 }
|
||
|
||
prtGeneralServicePerson OBJECT-TYPE
|
||
SYNTAX OCTET STRING (SIZE(0..127))
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The name of the person responsible for servicing this
|
||
printer. It is suggested that this string include
|
||
information that would enable other humans to reach the
|
||
service person, such as a phone number. As a convention
|
||
to facilitate automatic notification of the operator by
|
||
the agent or network management station, the phone
|
||
number, fax number or email address should be indicated
|
||
by the URL schemes 'tel:', 'fax:' and 'mailto:',
|
||
respectively. If either the phone, fax, or email
|
||
information is not available, then a line should not
|
||
be included for this information.
|
||
NOTE: For interoperability purposes, it is advisable to use
|
||
email addresses formatted per [RFC2822] requirements.
|
||
NOTE: The above description has been modified from RFC 1759
|
||
for clarification."
|
||
::= { prtGeneralEntry 5 }
|
||
|
||
prtInputDefaultIndex OBJECT-TYPE
|
||
SYNTAX Integer32 (1..65535)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The value of prtInputIndex corresponding to the default input
|
||
sub-unit: that is, this object selects the default source of
|
||
input media."
|
||
::= { prtGeneralEntry 6 }
|
||
|
||
prtOutputDefaultIndex OBJECT-TYPE
|
||
-- A range has been added to the SYNTAX clause that was not in
|
||
-- RFC 1759. Although this violates SNMP compatibility rules,
|
||
-- it provides a more reasonable guide for SNMP managers.
|
||
SYNTAX Integer32 (1..65535)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The value of prtOutputIndex corresponding to the default
|
||
output sub-unit; that is, this object selects the default
|
||
output destination."
|
||
::= { prtGeneralEntry 7 }
|
||
|
||
prtMarkerDefaultIndex OBJECT-TYPE
|
||
SYNTAX Integer32 (1..65535)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The value of prtMarkerIndex corresponding to the
|
||
default marker sub-unit; that is, this object selects the
|
||
default marker."
|
||
::= { prtGeneralEntry 8 }
|
||
|
||
prtMediaPathDefaultIndex OBJECT-TYPE
|
||
SYNTAX Integer32 (1..65535)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The value of prtMediaPathIndex corresponding to
|
||
the default media path; that is, the selection of the
|
||
default media path."
|
||
::= { prtGeneralEntry 9 }
|
||
|
||
prtConsoleLocalization OBJECT-TYPE
|
||
SYNTAX Integer32 (1..65535)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The value of the prtLocalizationIndex corresponding to
|
||
the language, country, and character set to be used for the
|
||
console. This localization applies both to the actual display
|
||
on the console as well as the encoding of these console objects
|
||
in management operations. When an object's 'charset' is
|
||
controlled by the value of prtConsoleLocalization, it MUST
|
||
specify PrtConsoleDescriptionStringTC as its syntax.
|
||
NOTE: The above description has been modified from RFC 1759
|
||
for clarification."
|
||
::= { prtGeneralEntry 10 }
|
||
|
||
prtConsoleNumberOfDisplayLines OBJECT-TYPE
|
||
SYNTAX Integer32 (0..65535)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The number of lines on the printer's physical
|
||
display. This value is 0 if there are no lines on the
|
||
physical display or if there is no physical display"
|
||
::= { prtGeneralEntry 11 }
|
||
|
||
prtGeneralPrinterName OBJECT-TYPE
|
||
SYNTAX OCTET STRING (SIZE (0..127))
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"An administrator-specified name for this printer. Depending
|
||
upon implementation of this printer, the value of this object
|
||
may or may not be same as the value for the MIB-II 'SysName'
|
||
object."
|
||
::= { prtGeneralEntry 16 }
|
||
|
||
prtGeneralSerialNumber OBJECT-TYPE
|
||
SYNTAX OCTET STRING (SIZE (0..255))
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"A recorded serial number for this device that indexes some
|
||
type device catalog or inventory. This value is usually set by
|
||
the device manufacturer but the MIB supports the option of
|
||
writing for this object for site-specific administration of
|
||
device inventory or tracking."
|
||
::= { prtGeneralEntry 17 }
|
||
|
||
prtCoverDescription OBJECT-TYPE
|
||
-- In RFC 1759, the SYNTAX was OCTET STRING. This has been changed
|
||
-- to a TC to better support localization of the object.
|
||
SYNTAX PrtLocalizedDescriptionStringTC
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The manufacturer provided cover sub-mechanism name in the
|
||
localization specified by prtGeneralCurrentLocalization."
|
||
::= { prtCoverEntry 2 }
|
||
|
||
prtCoverStatus OBJECT-TYPE
|
||
-- NOTE: In RFC 1759, the enumeration values were implicitly defined
|
||
-- by this object and are now defined in the IANA-PRINTER-MIB. The
|
||
-- new TC has defined "coverOpen" and "coverClosed" to replace
|
||
-- "doorOpen" and "doorClosed" in RFC 1759. A name change is not
|
||
-- formally allowed per SMI rules, but was agreed to by the WG group
|
||
-- since a door has a more restrictive meaning than a cover and
|
||
-- Cover group is intended to support doors as a subset of covers.
|
||
SYNTAX PrtCoverStatusTC
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The status of this cover sub-unit."
|
||
::= { prtCoverEntry 3 }
|
||
|
||
prtLocalizationLanguage OBJECT-TYPE
|
||
-- Note: The size is fixed, was incorrectly 0..2 in RFC 1759.
|
||
SYNTAX OCTET STRING (SIZE(2))
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"A two character language code from ISO 639. Examples en,
|
||
es, fr, de. NOTE: These examples were shown as upper case in
|
||
RFC 1759 and are now shown as lower case to agree with ISO 639."
|
||
::= { prtLocalizationEntry 2 }
|
||
|
||
prtLocalizationCountry OBJECT-TYPE
|
||
-- Note: The size is fixed, was incorrectly 0..2 in RFC 1759.
|
||
SYNTAX OCTET STRING (SIZE(2))
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"A two character country code from ISO 3166, a blank string
|
||
(two space characters) shall indicate that the country is not
|
||
defined. Examples: US, GB, FR, DE, ..."
|
||
::= { prtLocalizationEntry 3 }
|
||
|
||
prtLocalizationCharacterSet OBJECT-TYPE
|
||
SYNTAX IANACharset
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The coded character set used for this localization."
|
||
::= { prtLocalizationEntry 4 }
|
||
|
||
prtInputType OBJECT-TYPE
|
||
-- NOTE: In RFC 1759, the enumeration values were implicitly
|
||
-- defined by this object.
|
||
SYNTAX PrtInputTypeTC
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The type of technology (discriminated primarily according to
|
||
feeder mechanism type) employed by the input sub-unit. Note,
|
||
the Input Class provides for a descriptor field to further
|
||
qualify the other choice."
|
||
::= { prtInputEntry 2 }
|
||
|
||
prtInputDimUnit OBJECT-TYPE
|
||
SYNTAX PrtMediaUnitTC
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The unit of measurement for use calculating and relaying
|
||
dimensional values for this input sub-unit."
|
||
::= { prtInputEntry 3 }
|
||
|
||
prtInputMediaDimFeedDirDeclared OBJECT-TYPE
|
||
-- NOTE: In RFC 1759, the range was not defined.
|
||
SYNTAX Integer32 (-2..2147483647)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"This object provides the value of the declared dimension, in
|
||
the feed direction, of the media that is (or, if empty, was or
|
||
will be) in this input sub-unit. The feed direction is the
|
||
direction in which the media is fed on this sub-unit. This
|
||
dimension is measured in input sub-unit dimensional units
|
||
(controlled by prtInputDimUnit, which uses PrtMediaUnitTC). If
|
||
this input sub-unit can reliably sense this value, the value is
|
||
sensed by the printer and may not be changed by management
|
||
requests. Otherwise, the value may be changed. The value (-1)
|
||
means other and specifically means that this sub-unit places no
|
||
restriction on this parameter. The value (-2) indicates
|
||
unknown."
|
||
::= { prtInputEntry 4 }
|
||
|
||
prtInputMediaDimXFeedDirDeclared OBJECT-TYPE
|
||
-- NOTE: In RFC 1759, the range was not defined.
|
||
SYNTAX Integer32 (-2..2147483647)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"This object provides the value of the declared dimension, in
|
||
the cross feed direction, of the media that is (or, if empty,
|
||
was or will be) in this input sub-unit. The cross feed
|
||
direction is ninety degrees relative to the feed direction
|
||
associated with this sub-unit. This dimension is measured in
|
||
input sub-unit dimensional units (controlled by
|
||
prtInputDimUnit,which uses PrtMediaUnitTC). If this input sub-
|
||
unit can reliably sense this value, the value is sensed by the
|
||
printer and may not be changed by management requests.
|
||
Otherwise, the value may be changed. The value (-1) means other
|
||
and specifically means that this sub-unit places no restriction
|
||
on this parameter. The value (-2) indicates unknown."
|
||
::= { prtInputEntry 5 }
|
||
|
||
prtInputMediaDimFeedDirChosen OBJECT-TYPE
|
||
-- NOTE: In RFC 1759, the range was not defined.
|
||
SYNTAX Integer32 (-2..2147483647)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The printer will act as if media of the chosen dimension (in
|
||
the feed direction) is present in this input source. Note that
|
||
this value will be used even if the input tray is empty. Feed
|
||
dimension measurements are taken relative to the feed direction
|
||
associated with that sub-unit and are in input sub-unit
|
||
dimensional units (controlled by prtInputDimUnit, which uses
|
||
PrtMediaUnitTC). If the printer supports the declared
|
||
dimension,the granted dimension is the same as the declared
|
||
dimension. If not, the granted dimension is set to the closest
|
||
dimension that the printer supports when the declared dimension
|
||
is set. The value (-1) means other and specifically indicates
|
||
that this sub-unit places no restriction on this parameter. The
|
||
value (-2)indicates unknown."
|
||
::= { prtInputEntry 6 }
|
||
|
||
prtInputMediaDimXFeedDirChosen OBJECT-TYPE
|
||
-- NOTE: In RFC 1759, the range was not defined.
|
||
SYNTAX Integer32 (-2..2147483647)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The printer will act as if media of the chosen dimension (in
|
||
the cross feed direction) is present in this input source. Note
|
||
that this value will be used even if the input tray is empty.
|
||
The cross feed direction is ninety degrees relative to the feed
|
||
direction associated with this sub-unit. This dimension is
|
||
measured in input sub-unit dimensional units (controlled by
|
||
prtInputDimUnit, which uses PrtMediaUnitTC). If the printer
|
||
supports the declare dimension, the granted dimension is the
|
||
same as the declared dimension. If not, the granted dimension
|
||
is set to the closest dimension that the printer supports when
|
||
the declared dimension is set. The value (-1) means other and
|
||
specifically indicates that this sub-unit places no restriction
|
||
on this parameter. The value (-2) indicates unknown."
|
||
::= { prtInputEntry 7 }
|
||
|
||
prtInputCapacityUnit OBJECT-TYPE
|
||
-- NOTE: In RFC 1759, the enumeration values were implicitly
|
||
-- defined by this object.
|
||
SYNTAX PrtCapacityUnitTC
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The unit of measurement for use in calculating and relaying
|
||
capacity values for this input sub-unit."
|
||
::= { prtInputEntry 8 }
|
||
|
||
prtInputMaxCapacity OBJECT-TYPE
|
||
-- NOTE: In RFC 1759, the range was not defined.
|
||
SYNTAX Integer32 (-2..2147483647)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The maximum capacity of the input sub-unit in input sub-unit
|
||
capacity units (PrtCapacityUnitTC). There is no convention
|
||
associated with the media itself so this value reflects claimed
|
||
capacity. If this input sub-unit can reliably sense this value,
|
||
the value is sensed by the printer and may not be changed by
|
||
management requests; otherwise, the value may be written (by a
|
||
Remote Control Panel or a Management Application). The value
|
||
(-1) means other and specifically indicates that the sub-unit
|
||
places no restrictions on this parameter. The value (-2) means
|
||
unknown."
|
||
::= { prtInputEntry 9 }
|
||
|
||
prtInputCurrentLevel OBJECT-TYPE
|
||
-- NOTE: In RFC 1759, the range was not defined.
|
||
SYNTAX Integer32 (-3..2147483647) -- in capacity units
|
||
-- (PrtCapacityUnitTC).
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The current capacity of the input sub-unit in input sub-unit
|
||
capacity units (PrtCapacityUnitTC). If this input sub-unit can
|
||
reliably sense this value, the value is sensed by the printer
|
||
and may not be changed by management requests; otherwise, the
|
||
value may be written (by a Remote Control Panel or a Management
|
||
Application). The value (-1) means other and specifically
|
||
indicates that the sub-unit places no restrictions on this
|
||
parameter. The value (-2) means unknown. The value (-3) means
|
||
that the printer knows that at least one unit remains."
|
||
::= { prtInputEntry 10 }
|
||
|
||
prtInputStatus OBJECT-TYPE
|
||
SYNTAX PrtSubUnitStatusTC
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The current status of this input sub-unit."
|
||
::= { prtInputEntry 11 }
|
||
|
||
prtInputMediaName OBJECT-TYPE
|
||
SYNTAX OCTET STRING (SIZE(0..63))
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"A description of the media contained in this input sub-unit;
|
||
This description is to be used by a client to format and
|
||
Localize a string for display to a human operator. This
|
||
description is not processed by the printer. It is used to
|
||
provide information not expressible in terms of the other
|
||
media attributes (e.g., prtInputMediaDimFeedDirChosen,
|
||
prtInputMediaDimXFeedDirChosen, prtInputMediaWeight,
|
||
prtInputMediaType)."
|
||
-- The following reference was not included in RFC 1759.
|
||
REFERENCE
|
||
"The PWG Standardized Media Names specification [PWGMEDIA]
|
||
contains the recommended values for this object. See also
|
||
RFC 3805 Appendix C,'Media Names', which lists the values
|
||
Of standardized media names defined in ISO/IEC 10175."
|
||
::= { prtInputEntry 12 }
|
||
|
||
prtInputName OBJECT-TYPE
|
||
SYNTAX OCTET STRING (SIZE(0..63))
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The name assigned to this input sub-unit."
|
||
::= { prtInputEntry 13 }
|
||
|
||
prtInputVendorName OBJECT-TYPE
|
||
SYNTAX OCTET STRING (SIZE(0..63))
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The vendor name of this input sub-unit."
|
||
::= { prtInputEntry 14 }
|
||
|
||
prtInputModel OBJECT-TYPE
|
||
SYNTAX OCTET STRING (SIZE(0..63))
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The model name of this input sub-unit."
|
||
::= { prtInputEntry 15 }
|
||
|
||
prtInputVersion OBJECT-TYPE
|
||
SYNTAX OCTET STRING (SIZE(0..63))
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The version of this input sub-unit."
|
||
::= { prtInputEntry 16 }
|
||
|
||
prtInputSerialNumber OBJECT-TYPE
|
||
SYNTAX OCTET STRING (SIZE(0..32))
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The serial number assigned to this input sub-unit."
|
||
::= { prtInputEntry 17 }
|
||
|
||
prtInputDescription OBJECT-TYPE
|
||
-- In RFC 1759, the SYNTAX was OCTET STRING. This has been changed
|
||
-- to a TC to better support localization of the object.
|
||
SYNTAX PrtLocalizedDescriptionStringTC
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"A free-form text description of this input sub-unit in the
|
||
localization specified by prtGeneralCurrentLocalization."
|
||
::= { prtInputEntry 18 }
|
||
|
||
prtInputSecurity OBJECT-TYPE
|
||
SYNTAX PresentOnOff
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates if this input sub-unit has some security associated
|
||
with it."
|
||
::= { prtInputEntry 19 }
|
||
|
||
prtInputMediaWeight OBJECT-TYPE
|
||
-- NOTE: In RFC 1759, the range was not defined.
|
||
SYNTAX Integer32 (-2..2147483647)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The weight of the medium associated with this input sub-unit
|
||
in grams / per meter squared. The value (-2) means unknown."
|
||
::= { prtInputEntry 20 }
|
||
|
||
prtInputMediaType OBJECT-TYPE
|
||
SYNTAX OCTET STRING (SIZE(0..63))
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The name of the type of medium associated with this input sub
|
||
unit. This name need not be processed by the printer; it might
|
||
simply be displayed to an operator.
|
||
NOTE: The above description has been modified from RFC 1759."
|
||
-- The following reference was not included in RFC 1759.
|
||
REFERENCE
|
||
"The PWG Standardized Media Names specification [PWGMEDIA],
|
||
section 3 Media Type Names, contains the recommended values for
|
||
this object. Implementers may add additional string values.
|
||
The naming conventions in ISO 9070 are recommended in order to
|
||
avoid potential name clashes."
|
||
::= { prtInputEntry 21 }
|
||
|
||
prtInputMediaColor OBJECT-TYPE
|
||
SYNTAX OCTET STRING (SIZE(0..63))
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The name of the color of the medium associated with
|
||
this input sub-unit using standardized string values.
|
||
NOTE: The above description has been modified from RFC 1759."
|
||
-- The following reference was not included in RFC 1759.
|
||
REFERENCE
|
||
"The PWG Standardized Media Names specification [PWGMEDIA],
|
||
section 4 Media Color Names, contains the recommended values
|
||
for this object. Implementers may add additional string values.
|
||
The naming conventions in ISO 9070 are recommended in order to
|
||
avoid potential name clashes."
|
||
::= { prtInputEntry 22 }
|
||
|
||
prtInputMediaFormParts OBJECT-TYPE
|
||
-- NOTE: In RFC 1759, the range was not defined.
|
||
SYNTAX Integer32 (-2..2147483647)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The number of parts associated with the medium
|
||
associated with this input sub-unit if the medium is a
|
||
multi-part form. The value (-1) means other and
|
||
specifically indicates that the device places no
|
||
restrictions on this parameter. The value (-2) means
|
||
unknown."
|
||
::= { prtInputEntry 23 }
|
||
|
||
prtInputMediaLoadTimeout OBJECT-TYPE
|
||
SYNTAX Integer32 (-2..2147483647)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"When the printer is not able to print due to a subunit being
|
||
empty or the requested media must be manually loaded, the
|
||
printer will wait for the duration (in seconds) specified by
|
||
this object. Upon expiration of the time-out, the printer will
|
||
take the action specified by prtInputNextIndex.
|
||
The event which causes the printer to enter the waiting state
|
||
is product specific. If the printer is not waiting for manually
|
||
fed media, it may switch from an empty subunit to a different
|
||
subunit without waiting for the time-out to expire.
|
||
A value of (-1) implies 'other' or 'infinite' which translates
|
||
to 'wait forever'. The action which causes printing to continue
|
||
is product specific. A value of (-2) implies 'unknown'."
|
||
::= { prtInputEntry 24 }
|
||
|
||
prtOutputType OBJECT-TYPE
|
||
-- NOTE: In RFC 1759, the enumeration values were implicitly defined
|
||
-- by this object.
|
||
SYNTAX PrtOutputTypeTC
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The type of technology supported by this output sub-unit."
|
||
::= { prtOutputEntry 2 }
|
||
|
||
prtOutputCapacityUnit OBJECT-TYPE
|
||
SYNTAX PrtCapacityUnitTC
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The unit of measurement for use in calculating and relaying
|
||
capacity values for this output sub-unit."
|
||
::= { prtOutputEntry 3 }
|
||
|
||
prtOutputMaxCapacity OBJECT-TYPE
|
||
-- NOTE: In RFC 1759, the range was not defined.
|
||
SYNTAX Integer32 (-2..2147483647)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The maximum capacity of this output sub-unit in output sub-
|
||
unit capacity units (PrtCapacityUnitTC). There is no convention
|
||
associated with the media itself so this value essentially
|
||
reflects claimed capacity. If this output sub-unit can reliably
|
||
sense this value, the value is sensed by the printer and may
|
||
not be changed by management requests; otherwise, the value may
|
||
be written (by a Remote Control Panel or a Management
|
||
Application). The value (-1) means other and specifically
|
||
indicates that the sub-unit places no restrictions on this
|
||
parameter. The value (-2) means unknown."
|
||
::= { prtOutputEntry 4 }
|
||
|
||
prtOutputRemainingCapacity OBJECT-TYPE
|
||
-- NOTE: In RFC 1759, the range was not defined.
|
||
SYNTAX Integer32 (-3..2147483647)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The remaining capacity of the possible output sub-unit
|
||
capacity in output sub-unit capacity units
|
||
(PrtCapacityUnitTC)of this output sub-unit. If this output sub-
|
||
unit can reliably sense this value, the value is sensed by the
|
||
printer and may not be modified by management requests;
|
||
otherwise, the value may be written (by a Remote Control Panel
|
||
or a Management Application). The value (-1) means other and
|
||
specifically indicates that the sub-unit places no restrictions
|
||
on this parameter. The value (-2) means unknown. The value
|
||
(-3) means that the printer knows that there remains capacity
|
||
for at least one unit."
|
||
::= { prtOutputEntry 5 }
|
||
|
||
prtOutputStatus OBJECT-TYPE
|
||
SYNTAX PrtSubUnitStatusTC
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The current status of this output sub-unit."
|
||
::= { prtOutputEntry 6 }
|
||
|
||
prtOutputName OBJECT-TYPE
|
||
SYNTAX OCTET STRING (SIZE(0..63))
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The name assigned to this output sub-unit."
|
||
::= { prtOutputEntry 7 }
|
||
|
||
prtOutputVendorName OBJECT-TYPE
|
||
SYNTAX OCTET STRING (SIZE(0..63))
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The vendor name of this output sub-unit."
|
||
::= { prtOutputEntry 8 }
|
||
|
||
prtOutputModel OBJECT-TYPE
|
||
SYNTAX OCTET STRING (SIZE(0..63))
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The model name assigned to this output sub-unit.
|
||
NOTE: The above description has been modified from RFC 1759
|
||
for clarification."
|
||
::= { prtOutputEntry 9 }
|
||
|
||
prtOutputVersion OBJECT-TYPE
|
||
SYNTAX OCTET STRING (SIZE(0..63))
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The version of this output sub-unit."
|
||
::= { prtOutputEntry 10 }
|
||
|
||
prtOutputSerialNumber OBJECT-TYPE
|
||
SYNTAX OCTET STRING (SIZE(0..63))
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The serial number assigned to this output sub-unit."
|
||
::= { prtOutputEntry 11 }
|
||
|
||
prtOutputDescription OBJECT-TYPE
|
||
-- In RFC 1759, the SYNTAX was OCTET STRING. This has been changed
|
||
-- to a TC to better support localization of the object.
|
||
SYNTAX PrtLocalizedDescriptionStringTC
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"A free-form text description of this output sub-unit in the
|
||
localization specified by prtGeneralCurrentLocalization."
|
||
::= { prtOutputEntry 12 }
|
||
|
||
prtOutputSecurity OBJECT-TYPE
|
||
SYNTAX PresentOnOff
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates if this output sub-unit has some security associated
|
||
with it and if that security is enabled or not."
|
||
::= { prtOutputEntry 13 }
|
||
|
||
prtOutputDimUnit OBJECT-TYPE
|
||
SYNTAX PrtMediaUnitTC
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The unit of measurement for use in calculating and relaying
|
||
dimensional values for this output sub-unit."
|
||
::= { prtOutputEntry 14 }
|
||
|
||
prtOutputMaxDimFeedDir OBJECT-TYPE
|
||
-- NOTE: In RFC 1759, the range was not defined.
|
||
SYNTAX Integer32 (-2..2147483647)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The maximum dimensions supported by this output sub-unit
|
||
for measurements taken parallel relative to the feed
|
||
direction associated with that sub-unit in output
|
||
sub-unit dimensional units (controlled by prtOutputDimUnit,
|
||
which uses PrtMediaUnitTC). If this output sub-unit can
|
||
reliably sense this value, the value is sensed by the printer
|
||
and may not be changed with management protocol operations.
|
||
The value (-1) means other and specifically indicates that the
|
||
sub-unit places no restrictions on this parameter. The value
|
||
(-2) means unknown.
|
||
NOTE: The above description has been modified from RFC 1759
|
||
for clarification and to explain the purpose of (-1) and (-2)."
|
||
::= { prtOutputEntry 15 }
|
||
|
||
prtOutputMaxDimXFeedDir OBJECT-TYPE
|
||
-- NOTE: In RFC 1759, the range was not defined.
|
||
SYNTAX Integer32 (-2..2147483647)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The maximum dimensions supported by this output sub-unit
|
||
for measurements taken ninety degrees relative to the
|
||
feed direction associated with that sub-unit in output
|
||
sub-unit dimensional units (controlled by prtOutputDimUnit,
|
||
which uses PrtMediaUnitTC). If this output sub-unit can
|
||
reliably sense this value, the value is sensed by the printer
|
||
and may not be changed with management protocol operations.
|
||
The value (-1) means other and specifically indicates that the
|
||
sub-unit places no restrictions on this parameter. The value
|
||
(-2) means unknown.
|
||
NOTE: The above description has been modified from RFC 1759
|
||
for clarification and to explain the purpose of (-1) and (-2)."
|
||
::= { prtOutputEntry 16 }
|
||
|
||
prtOutputMinDimFeedDir OBJECT-TYPE
|
||
-- NOTE: In RFC 1759, the range was not defined.
|
||
SYNTAX Integer32 (-2..2147483647)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The minimum dimensions supported by this output sub-unit
|
||
for measurements taken parallel relative to the feed
|
||
direction associated with that sub-unit in output
|
||
sub-unit dimensional units (controlled by prtOutputDimUnit,
|
||
which uses PrtMediaUnitTC). If this output sub-unit can
|
||
reliably sense this value, the value is sensed by the printer
|
||
and may not be changed with management protocol operations.
|
||
The value (-1) means other and specifically indicates that the
|
||
sub-unit places no restrictions on this parameter. The value
|
||
(-2) means unknown.
|
||
NOTE: The above description has been modified from RFC 1759
|
||
for clarification and to explain the purpose of (-1) and (-2)."
|
||
::= { prtOutputEntry 17 }
|
||
|
||
prtOutputMinDimXFeedDir OBJECT-TYPE
|
||
-- NOTE: In RFC 1759, the range was not defined.
|
||
SYNTAX Integer32 (-2..2147483647)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The minimum dimensions supported by this output sub-unit
|
||
for measurements taken ninety degrees relative to the
|
||
feed direction associated with that sub-unit in output
|
||
sub-unit dimensional units (controlled by prtOutputDimUnit,
|
||
which uses PrtMediaUnitTC). If this output sub-unit can
|
||
reliably sense this value, the value is sensed by the printer
|
||
and may not be changed with management protocol operations.
|
||
The value (-1) means other and specifically indicates that the
|
||
sub-unit places no restrictions on this parameter. The value
|
||
(-2) means unknown.
|
||
NOTE: The above description has been modified from RFC 1759
|
||
for clarification and to explain the purpose of (-1) and (-2)."
|
||
::= { prtOutputEntry 18 }
|
||
|
||
prtOutputStackingOrder OBJECT-TYPE
|
||
-- NOTE: In RFC 1759, the enumeration values were implicitly
|
||
-- defined by this object.
|
||
SYNTAX PrtOutputStackingOrderTC
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The current state of the stacking order for the
|
||
associated output sub-unit. 'FirstToLast' means
|
||
that as pages are output the front of the next page is
|
||
placed against the back of the previous page.
|
||
'LasttoFirst' means that as pages are output the back
|
||
of the next page is placed against the front of the
|
||
previous page."
|
||
::= { prtOutputEntry 19 }
|
||
|
||
prtOutputPageDeliveryOrientation OBJECT-TYPE
|
||
-- NOTE: In RFC 1759, the enumeration values were implicitly
|
||
-- defined by this object.
|
||
SYNTAX PrtOutputPageDeliveryOrientationTC
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The reading surface that will be 'up' when pages are
|
||
delivered to the associated output sub-unit. Values are
|
||
faceUp and faceDown. (Note: interpretation of these
|
||
values is in general context-dependent based on locale;
|
||
presentation of these values to an end-user should be
|
||
normalized to the expectations of the user)."
|
||
::= { prtOutputEntry 20 }
|
||
|
||
prtOutputBursting OBJECT-TYPE
|
||
SYNTAX PresentOnOff
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"This object indicates that the outputting sub-unit supports
|
||
bursting, and if so, whether the feature is enabled. Bursting
|
||
is the process by which continuous media is separated into
|
||
individual sheets, typically by bursting along pre-formed
|
||
perforations."
|
||
::= { prtOutputEntry 21 }
|
||
|
||
prtOutputDecollating OBJECT-TYPE
|
||
SYNTAX PresentOnOff
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"This object indicates that the output supports decollating,
|
||
and if so, whether the feature is enabled. Decollating is the
|
||
process by which the individual parts within a multi-part form
|
||
are separated and sorted into separate stacks for each part."
|
||
::= { prtOutputEntry 22 }
|
||
|
||
prtOutputPageCollated OBJECT-TYPE
|
||
SYNTAX PresentOnOff
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"This object indicates that the output sub-unit supports page
|
||
collation, and if so, whether the feature is enabled. See RFC
|
||
3805 Appendix A, Glossary Of Terms, for definition of how this
|
||
document defines collation.
|
||
NOTE: The above description has been modified from RFC 1759
|
||
for clarification."
|
||
::= { prtOutputEntry 23 }
|
||
|
||
prtOutputOffsetStacking OBJECT-TYPE
|
||
SYNTAX PresentOnOff
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"This object indicates that the output supports offset
|
||
stacking,and if so, whether the feature is enabled. See RFC
|
||
3805 Appendix A, Glossary Of Terms, for how Offset Stacking is
|
||
defined by this document.
|
||
NOTE: The above description has been modified from RFC 1759
|
||
for clarification."
|
||
::= { prtOutputEntry 24 }
|
||
|
||
prtMarkerMarkTech OBJECT-TYPE
|
||
-- NOTE: In RFC 1759, the enumeration values were implicitly
|
||
-- defined by this object.
|
||
SYNTAX PrtMarkerMarkTechTC
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The type of marking technology used for this marking
|
||
sub-unit."
|
||
::= { prtMarkerEntry 2 }
|
||
|
||
prtMarkerCounterUnit OBJECT-TYPE
|
||
-- NOTE: In RFC 1759, the enumeration values were implicitly
|
||
-- defined by this object.
|
||
SYNTAX PrtMarkerCounterUnitTC
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The unit that will be used by the printer when reporting
|
||
counter values for this marking sub-unit. The time units of
|
||
measure are provided for a device like a strip recorder that
|
||
does not or cannot track the physical dimensions of the media
|
||
and does not use characters, lines or sheets."
|
||
::= { prtMarkerEntry 3 }
|
||
|
||
prtMarkerLifeCount OBJECT-TYPE
|
||
SYNTAX Counter32
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The count of the number of units of measure counted during the
|
||
life of printer using units of measure as specified by
|
||
prtMarkerCounterUnit.
|
||
Note: This object should be implemented as a persistent object
|
||
with a reliable value throughout the lifetime of the printer."
|
||
::= { prtMarkerEntry 4 }
|
||
|
||
prtMarkerPowerOnCount OBJECT-TYPE
|
||
SYNTAX Counter32
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The count of the number of units of measure counted since the
|
||
equipment was most recently powered on using units of measure
|
||
as specified by prtMarkerCounterUnit."
|
||
::= { prtMarkerEntry 5 }
|
||
|
||
prtMarkerProcessColorants OBJECT-TYPE
|
||
SYNTAX Integer32 (0..65535)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The number of process colors supported by this marker. A
|
||
process color of 1 implies monochrome. The value of this
|
||
object and prtMarkerSpotColorants cannot both be 0. The value
|
||
of prtMarkerProcessColorants must be 0 or greater.
|
||
NOTE: The above description has been modified from RFC 1759
|
||
for clarification."
|
||
::= { prtMarkerEntry 6 }
|
||
|
||
prtMarkerSpotColorants OBJECT-TYPE
|
||
SYNTAX Integer32 (0..65535)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The number of spot colors supported by this marker. The value
|
||
of this object and prtMarkerProcessColorants cannot both be 0.
|
||
Must be 0 or greater.
|
||
NOTE: The above description has been modified from RFC 1759
|
||
for clarification."
|
||
::= { prtMarkerEntry 7 }
|
||
|
||
prtMarkerAddressabilityUnit OBJECT-TYPE
|
||
-- NOTE: In RFC 1759, the enumeration values were implicitly
|
||
-- defined by this object.
|
||
SYNTAX PrtMarkerAddressabilityUnitTC
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The unit of measure of distances, as applied to the marker's
|
||
resolution.
|
||
NOTE: The above description has been modified from RFC 1759
|
||
for clarification."
|
||
::= { prtMarkerEntry 8 }
|
||
|
||
prtMarkerAddressabilityFeedDir OBJECT-TYPE
|
||
-- NOTE: In RFC 1759, the range was not defined.
|
||
SYNTAX Integer32 (-2..2147483647)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The maximum number of addressable marking positions in the
|
||
feed direction per 10000 units of measure specified by
|
||
prtMarkerAddressabilityUnit. A value of (-1) implies 'other'
|
||
or 'infinite' while a value of (-2) implies 'unknown'.
|
||
NOTE: The above description has been modified from RFC 1759
|
||
for clarification."
|
||
::= { prtMarkerEntry 9 }
|
||
|
||
prtMarkerAddressabilityXFeedDir OBJECT-TYPE
|
||
-- NOTE: In RFC 1759, the range was not defined.
|
||
SYNTAX Integer32 (-2..2147483647)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The maximum number of addressable marking positions in the
|
||
cross feed direction in 10000 units of measure specified by
|
||
prtMarkerAddressabilityUnit. A value of (-1) implies 'other'
|
||
or 'infinite' while a value of (-2) implies 'unknown'.
|
||
NOTE: The above description has been modified from RFC 1759
|
||
for clarification."
|
||
::= { prtMarkerEntry 10 }
|
||
|
||
prtMarkerNorthMargin OBJECT-TYPE
|
||
-- NOTE: In RFC 1759, the range was not defined.
|
||
SYNTAX Integer32 (-2..2147483647)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The margin, in units identified by prtMarkerAddressabilityUnit,
|
||
from the leading edge of the medium as the medium flows through
|
||
the marking engine with the side to be imaged facing the
|
||
observer. The leading edge is the North edge and the other
|
||
edges are defined by the normal compass layout of directions
|
||
with the compass facing the observer. Printing within the area
|
||
bounded by all four margins is guaranteed for all interpreters.
|
||
The value (-2) means unknown."
|
||
::= { prtMarkerEntry 11 }
|
||
|
||
prtMarkerSouthMargin OBJECT-TYPE
|
||
-- NOTE: In RFC 1759, the range was not defined.
|
||
SYNTAX Integer32 (-2..2147483647)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The margin from the South edge (see prtMarkerNorthMargin) of
|
||
the medium in units identified by prtMarkerAddressabilityUnit.
|
||
Printing within the area bounded by all four margins is
|
||
guaranteed for all interpreters. The value (-2) means unknown."
|
||
::= { prtMarkerEntry 12 }
|
||
|
||
prtMarkerWestMargin OBJECT-TYPE
|
||
-- NOTE: In RFC 1759, the range was not defined.
|
||
SYNTAX Integer32 (-2..2147483647)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The margin from the West edge (see prtMarkerNorthMargin) of
|
||
the medium in units identified by prtMarkerAddressabilityUnit.
|
||
Printing within the area bounded by all four margins is
|
||
guaranteed for all interpreters. The value (-2) means unknown."
|
||
::= { prtMarkerEntry 13 }
|
||
|
||
prtMarkerEastMargin OBJECT-TYPE
|
||
-- NOTE: In RFC 1759, the range was not defined.
|
||
SYNTAX Integer32 (-2..2147483647)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The margin from the East edge (see prtMarkerNorthMargin) of
|
||
the medium in units identified by prtMarkerAddressabilityUnit.
|
||
Printing within the area bounded by all four margins is
|
||
guaranteed for all interpreters. The value (-2) means unknown."
|
||
::= { prtMarkerEntry 14 }
|
||
|
||
prtMarkerStatus OBJECT-TYPE
|
||
SYNTAX PrtSubUnitStatusTC
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The current status of this marker sub-unit."
|
||
::= { prtMarkerEntry 15 }
|
||
|
||
prtMarkerSuppliesMarkerIndex OBJECT-TYPE
|
||
SYNTAX Integer32 (0..65535)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The value of prtMarkerIndex corresponding to the marking sub
|
||
unit with which this marker supply sub-unit is associated."
|
||
::= { prtMarkerSuppliesEntry 2 }
|
||
|
||
prtMarkerSuppliesColorantIndex OBJECT-TYPE
|
||
SYNTAX Integer32 (0..65535)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The value of prtMarkerColorantIndex corresponding to the
|
||
colorant with which this marker supply sub-unit is associated.
|
||
This value shall be 0 if there is no colorant table or if this
|
||
supply does not depend on a single specified colorant.
|
||
NOTE: The above description has been modified from RFC 1759
|
||
for clarification."
|
||
::= { prtMarkerSuppliesEntry 3 }
|
||
|
||
prtMarkerSuppliesClass OBJECT-TYPE
|
||
-- NOTE: In RFC 1759, the enumeration values were implicitly
|
||
-- defined by this object.
|
||
SYNTAX PrtMarkerSuppliesClassTC
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates whether this supply entity represents a supply that
|
||
is consumed or a receptacle that is filled.
|
||
NOTE: The above description has been modified from RFC 1759
|
||
for clarification."
|
||
::= { prtMarkerSuppliesEntry 4 }
|
||
|
||
prtMarkerSuppliesType OBJECT-TYPE
|
||
-- NOTE: In RFC 1759, the enumeration values were implicitly
|
||
-- defined by this object.
|
||
SYNTAX PrtMarkerSuppliesTypeTC
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The type of this supply."
|
||
::= { prtMarkerSuppliesEntry 5 }
|
||
|
||
prtMarkerSuppliesDescription OBJECT-TYPE
|
||
-- In RFC 1759, the SYNTAX was OCTET STRING. This has been changed
|
||
-- to a TC to better support localization of the object.
|
||
SYNTAX PrtLocalizedDescriptionStringTC
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The description of this supply container/receptacle in the
|
||
localization specified by prtGeneralCurrentLocalization."
|
||
::= { prtMarkerSuppliesEntry 6 }
|
||
|
||
prtMarkerSuppliesSupplyUnit OBJECT-TYPE
|
||
-- NOTE: In RFC 1759, the enumeration values were implicitly
|
||
-- defined by this object.
|
||
SYNTAX PrtMarkerSuppliesSupplyUnitTC
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Unit of measure of this marker supply container/receptacle.
|
||
NOTE: The above description has been modified from RFC 1759
|
||
for clarification."
|
||
::= { prtMarkerSuppliesEntry 7 }
|
||
|
||
prtMarkerSuppliesMaxCapacity OBJECT-TYPE
|
||
-- NOTE: In RFC 1759, the range was not defined.
|
||
SYNTAX Integer32 (-2..2147483647)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The maximum capacity of this supply container/receptacle
|
||
expressed in prtMarkerSuppliesSupplyUnit. If this supply
|
||
container/receptacle can reliably sense this value, the value
|
||
is reported by the printer and is read-only; otherwise, the
|
||
value may be written (by a Remote Control Panel or a Management
|
||
Application). The value (-1) means other and specifically
|
||
indicates that the sub-unit places no restrictions on this
|
||
parameter. The value (-2) means unknown."
|
||
::= { prtMarkerSuppliesEntry 8 }
|
||
|
||
prtMarkerSuppliesLevel OBJECT-TYPE
|
||
-- NOTE: In RFC 1759, the range was not defined.
|
||
SYNTAX Integer32 (-3..2147483647)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The current level if this supply is a container; the remaining
|
||
space if this supply is a receptacle. If this supply
|
||
container/receptacle can reliably sense this value, the value
|
||
is reported by the printer and is read-only; otherwise, the
|
||
value may be written (by a Remote Control Panel or a Management
|
||
Application). The value (-1) means other and specifically
|
||
indicates that the sub-unit places no restrictions on this
|
||
parameter. The value (-2) means unknown. A value of (-3) means
|
||
that the printer knows that there is some supply/remaining
|
||
space, respectively."
|
||
::= { prtMarkerSuppliesEntry 9 }
|
||
|
||
prtMarkerColorantMarkerIndex OBJECT-TYPE
|
||
SYNTAX Integer32 (0..65535)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The value of prtMarkerIndex corresponding to the marker sub
|
||
unit with which this colorant entry is associated."
|
||
::= { prtMarkerColorantEntry 2 }
|
||
|
||
prtMarkerColorantRole OBJECT-TYPE
|
||
-- NOTE: In RFC 1759, the enumeration values were implicitly
|
||
-- defined by this object.
|
||
SYNTAX PrtMarkerColorantRoleTC
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The role played by this colorant."
|
||
::= { prtMarkerColorantEntry 3 }
|
||
|
||
prtMarkerColorantValue OBJECT-TYPE
|
||
-- NOTE: The string length range has been increased from RFC 1759.
|
||
SYNTAX OCTET STRING (SIZE(0..255))
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The name of the color of this colorant using standardized
|
||
string names from ISO 10175 (DPA) and ISO 10180 (SPDL) such as:
|
||
other
|
||
unknown
|
||
white
|
||
red
|
||
green
|
||
blue
|
||
cyan
|
||
magenta
|
||
yellow
|
||
black
|
||
Implementers may add additional string values. The naming
|
||
conventions in ISO 9070 are recommended in order to avoid
|
||
potential name clashes"
|
||
::= { prtMarkerColorantEntry 4 }
|
||
|
||
prtMarkerColorantTonality OBJECT-TYPE
|
||
-- NOTE: In RFC 1759, the range was not defined.
|
||
SYNTAX Integer32 (2..2147483647)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The distinct levels of tonality realizable by a marking sub
|
||
unit when using this colorant. This value does not include the
|
||
number of levels of tonal difference that an interpreter can
|
||
obtain by techniques such as half toning. This value must be at
|
||
least 2."
|
||
::= { prtMarkerColorantEntry 5 }
|
||
|
||
prtMediaPathMaxSpeedPrintUnit OBJECT-TYPE
|
||
-- NOTE: In RFC 1759, the enumeration values were implicitly
|
||
-- defined by this object.
|
||
SYNTAX PrtMediaPathMaxSpeedPrintUnitTC
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The unit of measure used in specifying the speed of all media
|
||
paths in the printer."
|
||
::= { prtMediaPathEntry 2 }
|
||
|
||
prtMediaPathMediaSizeUnit OBJECT-TYPE
|
||
SYNTAX PrtMediaUnitTC
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The units of measure of media size for use in calculating and
|
||
relaying dimensional values for all media paths in the
|
||
printer."
|
||
::= { prtMediaPathEntry 3 }
|
||
|
||
prtMediaPathMaxSpeed OBJECT-TYPE
|
||
-- NOTE: In RFC 1759, the range was not defined.
|
||
SYNTAX Integer32 (-2..2147483647)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The maximum printing speed of this media path expressed in
|
||
prtMediaPathMaxSpeedUnit's. A value of (-1) implies 'other'."
|
||
::= { prtMediaPathEntry 4 }
|
||
|
||
prtMediaPathMaxMediaFeedDir OBJECT-TYPE
|
||
-- NOTE: In RFC 1759, the range was not defined.
|
||
SYNTAX Integer32 (-2..2147483647)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The maximum physical media size in the feed direction of this
|
||
media path expressed in units of measure specified by
|
||
PrtMediaPathMediaSizeUnit. A value of (-1) implies 'unlimited'
|
||
a value of (-2) implies 'unknown'.
|
||
NOTE: The above description has been modified from RFC 1759
|
||
for clarification."
|
||
::= { prtMediaPathEntry 5 }
|
||
|
||
prtMediaPathMaxMediaXFeedDir OBJECT-TYPE
|
||
-- NOTE: In RFC 1759, the range was not defined.
|
||
SYNTAX Integer32 (-2..2147483647)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The maximum physical media size across the feed direction of
|
||
this media path expressed in units of measure specified by
|
||
prtMediaPathMediaSizeUnit. A value of (-2) implies 'unknown'.
|
||
NOTE: The above description has been modified from RFC 1759
|
||
for clarification."
|
||
::= { prtMediaPathEntry 6 }
|
||
|
||
prtMediaPathMinMediaFeedDir OBJECT-TYPE
|
||
-- NOTE: In RFC 1759, the range was not defined.
|
||
SYNTAX Integer32 (-2..2147483647)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The minimum physical media size in the feed direction of this
|
||
media path expressed in units of measure specified by
|
||
prtMediaPathMediaSizeUnit. A value of (-2) implies 'unknown'.
|
||
NOTE: The above description has been modified from RFC 1759
|
||
for clarification."
|
||
::= { prtMediaPathEntry 7 }
|
||
|
||
prtMediaPathMinMediaXFeedDir OBJECT-TYPE
|
||
-- NOTE: In RFC 1759, the range was not defined.
|
||
SYNTAX Integer32 (-2..2147483647)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The minimum physical media size across the feed direction of
|
||
this media path expressed in units of measure specified by
|
||
prtMediaPathMediaSizeUnit. A value of (-2) implies 'unknown'.
|
||
NOTE: The above description has been modified from RFC 1759
|
||
for clarification."
|
||
::= { prtMediaPathEntry 8 }
|
||
|
||
prtMediaPathType OBJECT-TYPE
|
||
-- NOTE: In RFC 1759, the enumeration values were implicitly
|
||
-- defined by this object.
|
||
SYNTAX PrtMediaPathTypeTC
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The type of the media path for this media path."
|
||
::= { prtMediaPathEntry 9 }
|
||
|
||
prtMediaPathDescription OBJECT-TYPE
|
||
-- In RFC 1759, the SYNTAX was OCTET STRING. This has been changed
|
||
-- to a TC to better support localization of the object.
|
||
SYNTAX PrtLocalizedDescriptionStringTC
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The manufacturer-provided description of this media path in
|
||
the localization specified by prtGeneralCurrentLocalization."
|
||
::= { prtMediaPathEntry 10 }
|
||
|
||
prtMediaPathStatus OBJECT-TYPE
|
||
SYNTAX PrtSubUnitStatusTC
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The current status of this media path."
|
||
::= { prtMediaPathEntry 11 }
|
||
|
||
prtChannelType OBJECT-TYPE
|
||
-- NOTE: In RFC 1759, the enumeration values were implicitly
|
||
-- defined by this object.
|
||
SYNTAX PrtChannelTypeTC
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The type of this print data channel. This object provides the
|
||
linkage to ChannelType-specific groups that may (conceptually)
|
||
extend the prtChannelTable with additional details about that
|
||
channel."
|
||
::= { prtChannelEntry 2 }
|
||
|
||
prtChannelProtocolVersion OBJECT-TYPE
|
||
SYNTAX OCTET STRING (SIZE(0..63))
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The version of the protocol used on this channel. The format
|
||
used for version numbering depends on prtChannelType."
|
||
::= { prtChannelEntry 3 }
|
||
|
||
prtChannelCurrentJobCntlLangIndex OBJECT-TYPE
|
||
-- NOTE: In RFC 1759, the range was not defined.
|
||
SYNTAX Integer32 (0..65535)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The value of prtInterpreterIndex corresponding to the Control
|
||
Language Interpreter for this channel. This interpreter defines
|
||
the syntax used for control functions, such as querying or
|
||
changing environment variables and identifying job boundaries
|
||
(e.g., PJL, PostScript, NPAP). A value of zero indicates that
|
||
there is no current Job Control Language Interpreter for this
|
||
channel.
|
||
NOTE: The above description has been modified from RFC 1759
|
||
for clarification."
|
||
::= { prtChannelEntry 4 }
|
||
|
||
prtChannelDefaultPageDescLangIndex OBJECT-TYPE
|
||
-- NOTE: In RFC 1759, the range was not defined.
|
||
SYNTAX Integer32 (0..65535)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The value of prtInterpreterIndex corresponding to the Page
|
||
Description Language Interpreter for this channel. This
|
||
interpreter defines the default Page Description Language
|
||
interpreter to be used for the print data unless the Control
|
||
Language is used to select a specific interpreter (e.g., PCL,
|
||
PostScript Language, auto-sense). A value of zero indicates
|
||
that there is no default page description language interpreter
|
||
for this channel.
|
||
NOTE: The above description has been modified from RFC 1759
|
||
for clarification."
|
||
::= { prtChannelEntry 5 }
|
||
|
||
prtChannelState OBJECT-TYPE
|
||
-- NOTE: In RFC 1759, the enumeration values were implicitly
|
||
-- defined by this object.
|
||
SYNTAX PrtChannelStateTC
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The state of this print data channel. The value determines
|
||
whether control information and print data is allowed through
|
||
this channel or not."
|
||
::= { prtChannelEntry 6 }
|
||
|
||
prtChannelIfIndex OBJECT-TYPE
|
||
SYNTAX InterfaceIndexOrZero -- Was Integer32 in RFC 1759.
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The value of ifIndex in the ifTable; see the Interfaces Group
|
||
MIB [RFC2863] which corresponds to this channel.
|
||
When more than one row of the ifTable is relevant, this is the
|
||
index of the row representing the topmost layer in the
|
||
interface hierarchy. A value of zero indicates that no
|
||
interface is associated with this channel.
|
||
NOTE: The above description has been modified from RFC 1759
|
||
for clarification."
|
||
::= { prtChannelEntry 7 }
|
||
|
||
prtChannelStatus OBJECT-TYPE
|
||
SYNTAX PrtSubUnitStatusTC
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The current status of the channel."
|
||
::= { prtChannelEntry 8 }
|
||
|
||
prtChannelInformation OBJECT-TYPE
|
||
SYNTAX OCTET STRING (SIZE (0..255))
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Auxiliary information to allow a printing application to use
|
||
the channel for data submission to the printer. An application
|
||
capable of using a specific PrtChannelType should be able to
|
||
use the combined information from the prtChannelInformation and
|
||
other channel and interface group objects to 'bootstrap' its
|
||
use of the channel. prtChannelInformation is not intended to
|
||
provide a general channel description, nor to provide
|
||
information that is available once the channel is in use.
|
||
The encoding and interpretation of the prtChannelInformation
|
||
object is specific to channel type. The description of each
|
||
PrtChannelType enum value for which prtChannelInformation is
|
||
defined specifies the appropriate encoding and interpretation,
|
||
including interaction with other objects. For channel types
|
||
that do not specify a prtChannelInformation value, its value
|
||
shall be null (0 length).
|
||
When a new PrtChannelType enumeration value is registered, its
|
||
accompanying description must specify the encoding and
|
||
interpretation of the prtChannelInformation value for the
|
||
channel type. prtChannelInformation semantics for an existing
|
||
PrtChannelType may be added or amended in the same manner as
|
||
described in section 2.4.1 for type 2 enumeration values.
|
||
The prtChannelInformation specifies values for a collection of
|
||
channel attributes, represented as text according to the
|
||
following rules:
|
||
1. The prtChannelInformation is not affected by localization.
|
||
2. The prtChannelInformation is a list of entries representing
|
||
the attribute values. Each entry consists of the following
|
||
items, in order:
|
||
a. A keyword, composed of alphabetic characters (A-Z, a-z)
|
||
represented by their NVT ASCII [RFC854] codes, that
|
||
identifies a channel attribute,
|
||
b. The NVT ASCII code for an Equals Sign (=) (code 61) to
|
||
delimit the keyword,
|
||
c. A data value encoded using rules specific to the
|
||
PrtChannelType to with the prtChannelInformation applies which
|
||
must in no case allow an octet with value 10 (the NVT ASCII
|
||
Line Feed code),
|
||
d. the NVT ASCII code for a Line Feed character (code 10) to
|
||
delimit the data value.
|
||
No other octets shall be present.
|
||
Keywords are case-sensitive. Conventionally, keywords are
|
||
capitalized (including each word of a multi-word keyword) and
|
||
since they occupy space in the prtChannelInformation, they are
|
||
kept short.
|
||
3. If a channel attribute has multiple values, it is
|
||
represented by multiple entries with the same keyword, each
|
||
specifying one value. Otherwise, there shall be at most one
|
||
entry for each attribute.
|
||
4. By default, entries may appear in any order. If there are
|
||
ordering constraints for particular entries, these must be
|
||
specified in their definitions.
|
||
5. The prtChannelInformation value by default consists of text
|
||
represented by NVT ASCII graphics character codes. However,
|
||
other representations may be specified:
|
||
a. In cases where the prtChannelInformation value contains
|
||
information not normally coded in textual form, whatever
|
||
symbolic representation is conventionally used for the
|
||
information should be used for encoding the
|
||
prtChannelInformation value. (For instance, a binary port value
|
||
might be represented as a decimal number using NVT ASCII
|
||
codes.) Such encoding must be specified in the definition of
|
||
the value.
|
||
b. The value may contain textual information in a character set
|
||
other than NVT ASCII graphics characters. (For instance, an
|
||
identifier might consist of ISO 10646 text encoded using the
|
||
UTF-8 encoding scheme.) Such a character set and its encoding
|
||
must be specified in the definition of the value.
|
||
6. For each PrtChannelType for which prtChannelInformation
|
||
entries are defined, the descriptive text associated with the
|
||
PrtChannelType enumeration value shall specify the following
|
||
information for each entry:
|
||
Title: Brief description phrase, e.g.: 'Port name',
|
||
'Service Name', etc.
|
||
Keyword: The keyword value, e.g.: 'Port' or 'Service'
|
||
Syntax: The encoding of the entry value if it cannot be
|
||
directly represented by NVT ASCII.
|
||
Status: 'Mandatory', 'Optional', or 'Conditionally
|
||
Mandatory'
|
||
Multiplicity: 'Single' or 'Multiple' to indicate whether the
|
||
entry may be present multiple times.
|
||
Description: Description of the use of the entry, other
|
||
information required to complete the definition
|
||
(e.g.: ordering constraints, interactions between
|
||
entries).
|
||
Applications that interpret prtChannelInformation should ignore
|
||
unrecognized entries, so they are not affected if new entry
|
||
types are added."
|
||
::= { prtChannelEntry 9 }
|
||
|
||
prtInterpreterLangFamily OBJECT-TYPE
|
||
-- NOTE: In RFC 1759, the enumeration values were implicitly
|
||
-- defined by this object.
|
||
SYNTAX PrtInterpreterLangFamilyTC
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The family name of a Page Description Language (PDL) or
|
||
control language which this interpreter in the printer can
|
||
interpret or emulate.
|
||
NOTE: The above description has been modified from RFC 1759
|
||
for clarification."
|
||
::= { prtInterpreterEntry 2 }
|
||
|
||
prtInterpreterLangLevel OBJECT-TYPE
|
||
SYNTAX OCTET STRING (SIZE(0..31))
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The level of the language which this interpreter is
|
||
interpreting or emulating. This might contain a value like
|
||
'5e'for an interpreter which is emulating level 5e of the PCL
|
||
language. It might contain '2' for an interpreter which is
|
||
emulating level 2 of the PostScript language. Similarly it
|
||
might contain '2' for an interpreter which is emulating level 2
|
||
of the HPGL language."
|
||
::= { prtInterpreterEntry 3 }
|
||
|
||
prtInterpreterLangVersion OBJECT-TYPE
|
||
SYNTAX OCTET STRING (SIZE(0..31))
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The date code or version of the language which this
|
||
interpreter is interpreting or emulating."
|
||
::= { prtInterpreterEntry 4 }
|
||
|
||
prtInterpreterDescription OBJECT-TYPE
|
||
-- In RFC 1759, the SYNTAX was OCTET STRING. This has been changed
|
||
-- to a TC to better support localization of the object.
|
||
SYNTAX PrtLocalizedDescriptionStringTC
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"A string to identify this interpreter in the localization
|
||
specified by prtGeneralCurrentLocalization as opposed to the
|
||
language which is being interpreted. It is anticipated that
|
||
this string will allow manufacturers to unambiguously identify
|
||
their interpreters."
|
||
::= { prtInterpreterEntry 5 }
|
||
|
||
prtInterpreterVersion OBJECT-TYPE
|
||
SYNTAX OCTET STRING (SIZE(0..31))
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The date code, version number, or other product specific
|
||
information tied to this interpreter. This value is associated
|
||
with the interpreter, rather than with the version of the
|
||
language which is being interpreted or emulated."
|
||
::= { prtInterpreterEntry 6 }
|
||
|
||
prtInterpreterDefaultOrientation OBJECT-TYPE
|
||
-- NOTE: In RFC 1759, the enumeration values were implicitly
|
||
-- defined by this object.
|
||
SYNTAX PrtPrintOrientationTC
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The current orientation default for this interpreter. This
|
||
value may be overridden for a particular job (e.g., by a
|
||
command in the input data stream)."
|
||
::= { prtInterpreterEntry 7 }
|
||
|
||
prtInterpreterFeedAddressability OBJECT-TYPE
|
||
-- NOTE: In RFC 1759, the range was not defined.
|
||
SYNTAX Integer32 (-2..2147483647)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The maximum interpreter addressability in the feed
|
||
direction in 10000 prtMarkerAddressabilityUnits (as specified
|
||
by prtMarkerDefaultIndex) for this interpreter. The
|
||
value (-1) means other and specifically indicates that the
|
||
sub-unit places no restrictions on this parameter. The value
|
||
(-2) means unknown.
|
||
NOTE: The above description has been modified from RFC 1759
|
||
for clarification."
|
||
::= { prtInterpreterEntry 8 }
|
||
|
||
prtInterpreterXFeedAddressability OBJECT-TYPE
|
||
-- NOTE: In RFC 1759, the range was not defined.
|
||
SYNTAX Integer32 (-2..2147483647)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The maximum interpreter addressability in the cross feed
|
||
direction in 10000 prtMarkerAddressabilityUnits (as specified
|
||
by prtMarkerDefaultIndex) for this interpreter. The
|
||
value (-1) means other and specifically indicates that the
|
||
sub-unit places no restrictions on this parameter. The value
|
||
(-2) means unknown.
|
||
NOTE: The above description has been modified from RFC 1759
|
||
for clarification."
|
||
::= { prtInterpreterEntry 9 }
|
||
|
||
prtInterpreterDefaultCharSetIn OBJECT-TYPE
|
||
SYNTAX IANACharset
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The default coded character set for input octets encountered
|
||
outside a context in which the Page Description Language
|
||
established the interpretation of the octets. (Input octets are
|
||
presented to the interpreter through a path defined in the
|
||
channel group.)"
|
||
::= { prtInterpreterEntry 10 }
|
||
|
||
prtInterpreterDefaultCharSetOut OBJECT-TYPE
|
||
SYNTAX IANACharset
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The default character set for data coming from this
|
||
interpreter through the printer's output channel (i.e. the
|
||
'backchannel')."
|
||
::= { prtInterpreterEntry 11 }
|
||
|
||
prtInterpreterTwoWay OBJECT-TYPE
|
||
-- NOTE: In RFC 1759, the enumeration values were implicitly
|
||
-- defined by this object.
|
||
SYNTAX PrtInterpreterTwoWayTC
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates whether or not this interpreter returns information
|
||
back to the host."
|
||
::= { prtInterpreterEntry 12 }
|
||
|
||
prtConsoleDisplayBufferText OBJECT-TYPE
|
||
-- In RFC 1759, the SYNTAX was OCTET STRING. This has been changed
|
||
-- to a TC to better support localization of the object.
|
||
SYNTAX PrtConsoleDescriptionStringTC
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The content of a line in the logical display buffer of
|
||
the operator's console of the printer. When a write
|
||
operation occurs, normally a critical message, to one of
|
||
the LineText strings, the agent should make that line
|
||
displayable if a physical display is present. Writing a zero
|
||
length string clears the line. It is an implementation-
|
||
specific matter as to whether the agent allows a line to be
|
||
overwritten before it has been cleared. Printer generated
|
||
strings shall be in the localization specified by
|
||
prtConsoleLocalization.Management Application generated strings
|
||
should be localized by the Management Application."
|
||
::= { prtConsoleDisplayBufferEntry 2 }
|
||
|
||
gdStatusLineState OBJECT-TYPE
|
||
SYNTAX Integer32 ( 0 .. 255 )
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"This describes the line state of the peripheral.
|
||
When non-zero, the peripheral is off-line. When
|
||
zero the peripheral is on-line."
|
||
::= { gdStatusEntry 1 }
|
||
|
||
gdStatusPaperOut OBJECT-TYPE
|
||
SYNTAX Integer32
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"This indicates that the peripheral is out of paper.
|
||
off (0),
|
||
paper-out-or-paper-mount (1),
|
||
manual-paper-feed-needed (2)"
|
||
::= { gdStatusEntry 8 }
|
||
|
||
gdStatusPaperJam OBJECT-TYPE
|
||
SYNTAX Integer32
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"This indicates that the peripheral has a paper jam.
|
||
off (0),
|
||
paper-jam(1)"
|
||
::= { gdStatusEntry 9 }
|
||
|
||
gdStatusBusy OBJECT-TYPE
|
||
SYNTAX Integer32 ( 0 .. 255 )
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"This indicates that the peripheral is busy processing
|
||
print/plot data."
|
||
::= { gdStatusEntry 14 }
|
||
|
||
gdStatusWait OBJECT-TYPE
|
||
SYNTAX Integer32 ( 0 .. 255 )
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"This indicates that the peripheral is waiting for print/plot
|
||
data to process."
|
||
::= { gdStatusEntry 15 }
|
||
|
||
gdStatusInitialize OBJECT-TYPE
|
||
SYNTAX Integer32
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"This indicates that the peripheral is initializing or
|
||
warming up.
|
||
off (0),
|
||
initializing (1),
|
||
warm-up(2)"
|
||
::= { gdStatusEntry 16 }
|
||
|
||
gdStatusDoorOpen OBJECT-TYPE
|
||
SYNTAX Integer32 ( 0 .. 255 )
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"This indicates that the peripheral cover or door is open."
|
||
::= { gdStatusEntry 17 }
|
||
|
||
gdStatusPrinting OBJECT-TYPE
|
||
SYNTAX Integer32
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"This indicates that the peripheral is printing or otherwise
|
||
marking or moving paper.
|
||
off (0),
|
||
ordinary-page (1),
|
||
test-fonts-config-or-start-page (2)"
|
||
::= { gdStatusEntry 18 }
|
||
|
||
gdStatusPaperOutput OBJECT-TYPE
|
||
SYNTAX Integer32
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"This indicates that the peripheral has a paper output problem
|
||
such as the output storage bin being full.
|
||
off (0),
|
||
output-storage-full (1)"
|
||
::= { gdStatusEntry 19 }
|
||
|
||
gdStatusDisplay OBJECT-TYPE
|
||
SYNTAX DisplayString
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The string diplayed on the peripheral front panel."
|
||
::= { generalDeviceStatus 3 }
|
||
|
||
gdStatusId OBJECT-TYPE
|
||
SYNTAX OCTET STRING ( SIZE ( 0 .. 1024 ) )
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"A formatted string of NVT ASCII
|
||
charactersdescribing this peripheral."
|
||
::= { generalDeviceStatus 7 }
|
||
|
||
gdStatusJobTimeout OBJECT-TYPE
|
||
SYNTAX Integer32
|
||
MAX-ACCESS read-write
|
||
STATUS obsolete
|
||
DESCRIPTION
|
||
"This value represents (in seconds) the maximum time of
|
||
inactivity which must elapse before the print server card
|
||
switches from the current network protocol to another when
|
||
a normal end of job is not detected."
|
||
::= { generalDeviceStatus 10 }
|
||
|
||
gdPasswords OBJECT-TYPE
|
||
SYNTAX OCTET STRING ( SIZE ( 0 .. 255 ) )
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"This object is used as a 256 byte NVRAM area for JetAdmin. It
|
||
is completely managed by JetAdmin. Initially it is initialized
|
||
to all zeros. A coldboot will re-initialize to all zeros."
|
||
::= { generalDeviceStatus 13 }
|
||
|
||
energy-star OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-write
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Returns or changes the Energy Star sleep value. If the value
|
||
is greater than zero, then the device will go into energy
|
||
saving sleep mode after the print engine has been idle for the
|
||
number of seconds specified by this object. A value of zero
|
||
means Energy Star is disabled and the device will not go to
|
||
sleep based on print engine idle time. The value must be
|
||
non-negative."
|
||
::= { settings-system 1 }
|
||
|
||
sleep-mode OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
eFalse(1),
|
||
eTrue(2)
|
||
}
|
||
ACCESS read-write
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Returns eTrue if the device is in energy saving sleep mode,
|
||
otherwise returns eFalse. Setting SLEEP-MODE to eFalse causes
|
||
the device to wake up, if it is in sleep mode. Setting
|
||
SLEEP-MODE to eTrue causes the device to go into sleep mode."
|
||
::= { settings-system 2 }
|
||
|
||
speed-energy-usage OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
eFasterFirstPage(1),
|
||
eSaveEnergy(2),
|
||
eSaveMostEnergy(3),
|
||
eSaveMoreEnergy(4)
|
||
}
|
||
ACCESS read-write
|
||
STATUS optional
|
||
DESCRIPTION "Option to keep the engine in a pre-warmed state to speed up
|
||
first page out."
|
||
::={ settings-system 50 }
|
||
|
||
start-engine-early-warmup OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
eValue1(1)
|
||
}
|
||
ACCESS write-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"This PML object is used by HP SW drivers to signal the printer
|
||
that a job is coming, and to start the warm-up process
|
||
early.The effect of warming up early will reduce the First Page
|
||
Out time."
|
||
::= { settings-system 99 }
|
||
|
||
enable-engine-early-warmup OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
eDisable(1),
|
||
eEnable(2)
|
||
}
|
||
ACCESS read-write
|
||
STATUS optional
|
||
DESCRIPTION "This PML object is used by HP SW to enable/disable the printer
|
||
to send the signal of warm-up process early to engine. The
|
||
effect of warming up early will reduce the First Page Out
|
||
time."
|
||
::= { settings-system 101 }
|
||
|
||
install-date OBJECT-TYPE
|
||
SYNTAX DisplayString (SIZE(13))
|
||
ACCESS read-write
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Identifies the date that the device was installed. The format
|
||
of the string is 'YYYYMMDDHHmmZ'. Where:
|
||
YYYY is the year.
|
||
MM is the month (1-12).
|
||
DD is the day (1-31).
|
||
HH is the hour of the day (0-23).
|
||
mm are the minutes (0-59).
|
||
'Z' designates Greenwich Mean Time; if 'Z' not specified,
|
||
value is local time.
|
||
Device POS must specify the conditions for setting this
|
||
object."
|
||
::= { status-system 8 }
|
||
|
||
date-and-time OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
ACCESS read-write
|
||
STATUS optional
|
||
DESCRIPTION "A C structure containing the following fields: typedef
|
||
struct {
|
||
ubyte yr; /* year: 0 to 99 */
|
||
ubyte mon; /* month: 1 to 12 */
|
||
ubyte day; /* day: 1 to 31 */
|
||
ubyte wday; /* Day of week: 1 to 07 */
|
||
ubyte hr; /* hour: 0 to 23 */
|
||
ubyte min; /* minute: 0 to 59 */
|
||
ubyte sec; /* second: 0 to 59 */
|
||
} date_t;
|
||
where ubyte is an unsigned byte (0-255)."
|
||
::= { status-system 17 }
|
||
|
||
model-number OBJECT-TYPE
|
||
SYNTAX DisplayString
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Identifies the device model number as listed in the HP
|
||
corporate price list (e.g. C2121A for DeskJet 500C). The string
|
||
is as specific as possible. Products should note in POS if the
|
||
model number on the CPL changes but the device reports the
|
||
previous model number. If the model number changes based on the
|
||
installed options, the POS should indicate if only the base
|
||
model number is returned, or if the device senses the installed
|
||
options and returns the correct model number. If possible,
|
||
encode the model number in a symbol set (like Roman-8) that
|
||
matches the ASCII character set and limit the characters used
|
||
to ASCII characters."
|
||
::= { id 1 }
|
||
|
||
model-name OBJECT-TYPE
|
||
SYNTAX DisplayString (SIZE(1..32))
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Identifies the device model name (e.g. ''DeskJet 1200C''). The
|
||
string is as specific as possible. Capitalization and spacing
|
||
should match family naming conventions. Products should note in
|
||
POS if the model name on the HP corporate price list changes
|
||
but the device reports the previous device name. If the model
|
||
name changes based on the installed options, the POS should
|
||
indicate if only the base model name is returned, or if the
|
||
device senses the installed options and returns the correct
|
||
model name. If possible, encode the model name in a symbol set
|
||
(like Roman-8) that matches the ASCII character set and limit
|
||
the characters used to ASCII characters."
|
||
::= { id 2 }
|
||
|
||
serial-number OBJECT-TYPE
|
||
SYNTAX DisplayString (SIZE(0..10))
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Identifies the serial number for the device. If the
|
||
SERIAL-NUMBER object is set by the user, then setting the
|
||
object does not need to be protected. If the SERIAL-NUMBER
|
||
object is set at the factory, then the SERVICE-PASSWORD object
|
||
must be set correctly before the SERIAL-NUMBER object is
|
||
writable. If this is a writable object, the POS should indicate
|
||
the maximum supported string length. If possible, encode the
|
||
serial number in a symbol set (like Roman-8) that matches the
|
||
ASCII character set and limit the characters used to ASCII
|
||
characters."
|
||
::= { id 3 }
|
||
|
||
fw-rom-datecode OBJECT-TYPE
|
||
SYNTAX DisplayString
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Identifies the base system firmware date code. The date code
|
||
will be encoded in the yyyymmdd format. There may be several
|
||
versions of the base system firmware. The date code associated
|
||
with the version of the base system firmware that is being used
|
||
is reported. There may be other date code objects for other
|
||
specific modules such as fonts, localization modules, etc.;
|
||
these other datecode objects are device specific."
|
||
::= { id 5 }
|
||
|
||
fw-rom-revision OBJECT-TYPE
|
||
SYNTAX DisplayString
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"This identifies the system code firmware ROM revision code. The
|
||
format for a revision is major_revision.minor_revision. There
|
||
may be other ROM revision code objects for other specific ROMs
|
||
such as font ROMs, localization ROMs, etc; these other ROM
|
||
revision code objects are device specific."
|
||
::= { id 6 }
|
||
|
||
device-name OBJECT-TYPE
|
||
SYNTAX DisplayString (SIZE(0..32))
|
||
ACCESS read-write
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"User defined device name. The POS should indicate the maximum
|
||
supported string length. If the user entered string is too
|
||
long, the device will store as much as possible and will return
|
||
the <OKNearestLegal ValueSubstituted>.Additional information:
|
||
The maximum supported string length is 32
|
||
characters. If the user entered string is too long,
|
||
the device will store the first 32 characters and will
|
||
return the <noError> status."
|
||
::= { id 10 }
|
||
|
||
device-location OBJECT-TYPE
|
||
SYNTAX DisplayString
|
||
ACCESS read-write
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"User defined device location. The POS should indicate the
|
||
maximum supported string length. If the user entered string is
|
||
too long, the device will store as much as possible and will
|
||
return the <OKNearestLegal ValueSubstituted>.Additional information:
|
||
The maximum supported string length is 16
|
||
characters. If the user entered string is too long,
|
||
the device will store the first 16 characters and will
|
||
return the <noError> status."
|
||
::= { id 11 }
|
||
|
||
asset-number OBJECT-TYPE
|
||
SYNTAX DisplayString
|
||
ACCESS read-write
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"User defined asset number. The POS should indicate the maximum
|
||
supported string length. If the user entered string is too
|
||
long, the device will store as much as possible and will return
|
||
the <OKNearestLegal ValueSubstituted>.Additional information:
|
||
The maximum supported string length is 8
|
||
characters. If the user entered string is too long,
|
||
the device will store the first 8 characters and will
|
||
return the <noError> status."
|
||
::= { id 12 }
|
||
|
||
print-internal-page OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
eNotPrintingAnInternalPage(1),
|
||
ePrintingAnUnknownInternalPage(2),
|
||
eDeviceDemoPage1ConfigurationPage(3),
|
||
eDeviceDemoPage2(4),
|
||
eDeviceDemoPage5ErrorLog(7),
|
||
eDeviceDemoPage6FileSystemDirectoryListing(8),
|
||
eDeviceDemoPage7MenuMap(9),
|
||
ePrintUsagePage(100),
|
||
eSuppliesPage(101),
|
||
eDevicePaperPathTest(254),
|
||
eDevicePageRegistrationPage(255),
|
||
ePrintQualityPages(256),
|
||
ePCLFontList1(350),
|
||
ePSFontList(450)
|
||
}
|
||
ACCESS read-write
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Writing this object to a value other than
|
||
eNotPrintingAnInternalPage causes the device to attempt to
|
||
print an internally generated page. Reading this object
|
||
provides an indication what internally generated page is
|
||
currently being printed, if any. The actual page is device
|
||
specific. Some devices may support continuously printing an
|
||
internally generated page. Setting this object to
|
||
eNotPrintingAnInternalPage terminates continuously printing
|
||
internally generated pages. An internally generated page may
|
||
not be allowed to be printed at any arbitrary time; under what
|
||
conditions it will succeed or fail is device specific. If the
|
||
device supports the requested page, but can not start printing
|
||
the page when requested, the device will respond with
|
||
<genErr>. RECOMMENDATION: If the
|
||
device is ready (i.e. the NOT-READY-PRINTER object does not
|
||
contain any items, except maybe being off-line) and is idle
|
||
(i.e. the NOT-IDLE object does not contain any items), this
|
||
request should always succeed. This provides a mechanism for
|
||
driver writers to always determine if the action will succeed
|
||
or not."
|
||
::= { test 2 }
|
||
|
||
cancel-job OBJECT-TYPE
|
||
SYNTAX INTEGER(0..32767)
|
||
ACCESS write-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Cancels the print job whose ID matches the value written to the
|
||
CANCEL-JOB object. The host first learns the job ID using the
|
||
CURRENT-JOB-PARSING-ID command. If the printer has completely
|
||
processed the job, the printer responds with
|
||
<badValue>. If the value of the
|
||
CURRENT-JOB-PARSING-ID is smaller than the value written to the
|
||
CANCEL-JOB object, then the printer responds with
|
||
<badValue>. When read, returns the value
|
||
of the last job ID what was canceled, or -1 to indicate no job
|
||
has been canceled.
|
||
Additional information:
|
||
If the value written matches the ID of a job that is
|
||
currently being canceled (for any reason),
|
||
the printer responds with <noError>.
|
||
LaserJet 8150 uses job ID's in the range of 0..32767.
|
||
Because the ID number can wrap to zero,
|
||
CURRENT-JOB-PARSING-ID may be smaller than the value
|
||
written to this object; when this occurs, no error
|
||
will result as long as the ID is for a currently
|
||
processing job. This object is write only, so the
|
||
comment in the general description stating the
|
||
job ID or -1 will be returned on a read does not
|
||
apply."
|
||
::= { settings-job 2 }
|
||
|
||
encryption-password-type OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
eFalse(0),
|
||
eTrue(1)
|
||
}
|
||
ACCESS read-write
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"This Object will allow the Customer to query for the supported
|
||
encryption type. Its value will be set to AlphaNumeric (Value
|
||
as 1) if password can be alphanumeric and Numeric (Value as 0)
|
||
otherwise."
|
||
::= { settings-job 15 }
|
||
|
||
encryption-password-max-length OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-write
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"This Object will allow the Customer to query for the max
|
||
password length of a secure encrypted job supported by the
|
||
device. Its value will be set to 12 for 4-line devices and 32
|
||
for all others."
|
||
::= { settings-job 16 }
|
||
|
||
encryption-password-min-length OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-write
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"This Object will allow the Customer to query for the min
|
||
password length of a secure encrypted job supported by the
|
||
device. Its value will be set to 4."
|
||
::= { settings-job 17 }
|
||
|
||
job-storage-supported OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
eFalse(0),
|
||
eTrue(1)
|
||
}
|
||
ACCESS read-write
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"This object returns eTrue(1) if job storage is supported on
|
||
this device and eFalse(0) if job storage is not supported.
|
||
USE: The client or driver can query this object in
|
||
order to determine whether job storage is supported."
|
||
::= { settings-job 18 }
|
||
|
||
job-storage-type OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
ACCESS read-write
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"This object indicates what kind of stored job types this device
|
||
supports. A returned value of none indicates that the job
|
||
storage is not supported. A returned value of retentive
|
||
indicates that stored jobs are retained across a power cycle. A
|
||
returned value of volatile indicates that stored jobs will be
|
||
lost when a power-cycle occurs. In case device supports
|
||
multiple Job Storage types, it would return the comma separated
|
||
string with all supported values e.g. retentive,volatile USE:
|
||
The client or driver can query this object to determine whether
|
||
the device has the capability to retain stored jobs across a
|
||
power cycle."
|
||
::= { settings-job 19 }
|
||
|
||
job-storage-mode OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
ACCESS read-write
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"This object indicates what kind of stored job modes this device
|
||
supports. A returned value of none indicates that the device
|
||
does not support job storage. A returned value of save-only
|
||
indicates that the device is configured for save only mode. A
|
||
returned value of print-save indicates that the device supports
|
||
Print and Save mode. In case device supports multiple Job
|
||
Storage modes, it would return the comma separated string with
|
||
all supported values e.g.save-only,print-save. Save-only job
|
||
storage mode indicates that jobs would be stored on device,
|
||
while print-save mode indicates that job would be printed as
|
||
well stored on device. USE The client or driver can query this
|
||
object to see whether the printer has the capability to store
|
||
jobs or to store and print jobs."
|
||
::= { settings-job 20 }
|
||
|
||
job-storage-available OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
eFalse(0),
|
||
eTrue(1)
|
||
}
|
||
ACCESS read-write
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"This object indicates whether job storage is available on the
|
||
device. The default is eTrue(1) but if storage is not available
|
||
for any reason the return value will be eFalse(0). USE The
|
||
client or driver can query object to see if job storage is
|
||
available."
|
||
::= { settings-job 21 }
|
||
|
||
job-storage-encryption OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
ACCESS read-write
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"This object indicates the kind of encryption supported by
|
||
device. USE The client or driver can query this object to
|
||
determine the kind of encryption supported by this device. In
|
||
case device supports multiple encryption types, it would return
|
||
the comma separated string of all supported encryption types
|
||
e.g. 'aes128,aes256'."
|
||
::= { settings-job 22 }
|
||
|
||
current-job-parsing-id OBJECT-TYPE
|
||
SYNTAX INTEGER(-1..2147483647)
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Contains the printer assigned job identification for the job
|
||
currently being processed by the processing PDL sub-system. The
|
||
job ID is a monotonically increasing number. The job ID may be
|
||
reset to zero at power-up and may roll over to zero after
|
||
reaching some maximum value.
|
||
Additional information:
|
||
A value of -1 is returned when the printer
|
||
is not parsing a job.
|
||
When data for a new job is detected, this object is
|
||
updated (the job may or may not turn out to be a Null
|
||
Job); however, the trap does not occur until the printer
|
||
determines that it is not a Null Job. (A job is considered
|
||
to be a 'null job' if it has no name or job attribute,
|
||
causes no pages to be printed, and consumes MIN_JOB_SIZE
|
||
(9) or fewer bytes.) A trapped value will differ from
|
||
the previous value by one or more. See the Job Boundary
|
||
ERS for details on what constitutes a job boundary.
|
||
Some job-info- objects are created when the first data
|
||
bytes are received. If the printer determines that the
|
||
job is a Null Job, the job-info- objects related to the
|
||
Null Job are deleted. LaserJet 8100 retains the job-info-
|
||
objects for the MAX_JOBS_IN_LIST (32) most recent jobs
|
||
that are not Null Jobs.
|
||
The first job received after power-up will have job ID 1,
|
||
and the job ID will increment to 2,147,483,647 before
|
||
rolling to zero. To distinguish whether a power cycle or a
|
||
rollover causes a reduction in the job ID value, the
|
||
object prtGeneralConfigChanges can be watched and if it
|
||
increments at the same time as the drop is observed in
|
||
the value of CURRENT-JOB-PARSING-ID, then a power cycle
|
||
is the most likely cause."
|
||
::= { job-being-parsed 1 }
|
||
|
||
error1-time-stamp OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Contains some sort of time stamp indicating when error 1
|
||
occurred. Example time stamps include the actual time the error
|
||
occurred (in seconds since Jan. 1, 1970), and the total engine
|
||
page count. The device POS documents the meaning of the time
|
||
stamp."
|
||
::= { error1 1 }
|
||
|
||
error1-code OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Contains a device specific error code. Each device POS should
|
||
list what errors are logged to the error log and the meaning of
|
||
each supported error code value."
|
||
::= { error1 2 }
|
||
|
||
error1-date-time OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION "This item contains the date and the time at which an error
|
||
occurred. The values returned will be in hexadecimal. If the
|
||
date is 2004-Jul-13 and the time is 03:15 a.m., we get 04 07 0d
|
||
03 0f where,
|
||
04 (hex) - corresponds to the year 2004.
|
||
07 (hex) - corresponds to month, 07
|
||
0d (hex) - corresponds to date, 13
|
||
03 (hex) - corresponds to hour, 3 a.m.
|
||
0f (hex) - corresponds to min, 15."
|
||
::= { error1 3 }
|
||
|
||
error2-time-stamp OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Contains some sort of time stamp indicating when error 2
|
||
occurred. Example time stamps include the actual time the error
|
||
occurred (in seconds since Jan. 1, 1970), and the total engine
|
||
page count. The device POS documents the meaning of the time
|
||
stamp."
|
||
::= { error2 1 }
|
||
|
||
error2-code OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Contains a device specific error code. Each device POS should
|
||
list what errors are logged to the error log and the meaning of
|
||
each supported error code value."
|
||
::= { error2 2 }
|
||
|
||
error2-date-time OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION "This item contains the date and the time at which an error
|
||
occurred. The values returned will be in hexadecimal. If the
|
||
date is 2004-Jul-13 and the time is 03:15 a.m., we get 04 07 0d
|
||
03 0f where,
|
||
04 (hex) - corresponds to the year 2004.
|
||
07 (hex) - corresponds to month, 07
|
||
0d (hex) - corresponds to date, 13
|
||
03 (hex) - corresponds to hour, 3 a.m.
|
||
0f (hex) - corresponds to min, 15."
|
||
::= { error2 3 }
|
||
|
||
error3-time-stamp OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Contains some sort of time stamp indicating when error 3
|
||
occurred. Example time stamps include the actual time the error
|
||
occurred (in seconds since Jan. 1, 1970), and the total engine
|
||
page count. The device POS documents the meaning of the time
|
||
stamp."
|
||
::= { error3 1 }
|
||
|
||
error3-code OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Contains a device specific error code. Each device POS should
|
||
list what errors are logged to the error log and the meaning of
|
||
each supported error code value."
|
||
::= { error3 2 }
|
||
|
||
error3-date-time OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION "This item contains the date and the time at which an error
|
||
occurred. The values returned will be in hexadecimal. If the
|
||
date is 2004-Jul-13 and the time is 03:15 a.m., we get 04 07 0d
|
||
03 0f where,
|
||
04 (hex) - corresponds to the year 2004.
|
||
07 (hex) - corresponds to month, 07
|
||
0d (hex) - corresponds to date, 13
|
||
03 (hex) - corresponds to hour, 3 a.m.
|
||
0f (hex) - corresponds to min, 15."
|
||
::= { error3 3 }
|
||
|
||
error4-time-stamp OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Contains some sort of time stamp indicating when error 4
|
||
occurred. Example time stamps include the actual time the error
|
||
occurred (in seconds since Jan. 1, 1970), and the total engine
|
||
page count. The device POS documents the meaning of the time
|
||
stamp."
|
||
::= { error4 1 }
|
||
|
||
error4-code OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Contains a device specific error code. Each device POS should
|
||
list what errors are logged to the error log and the meaning of
|
||
each supported error code value."
|
||
::= { error4 2 }
|
||
|
||
error4-date-time OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION "This item contains the date and the time at which an error
|
||
occurred. The values returned will be in hexadecimal. If the
|
||
date is 2004-Jul-13 and the time is 03:15 a.m., we get 04 07 0d
|
||
03 0f where,
|
||
04 (hex) - corresponds to the year 2004.
|
||
07 (hex) - corresponds to month, 07
|
||
0d (hex) - corresponds to date, 13
|
||
03 (hex) - corresponds to hour, 3 a.m.
|
||
0f (hex) - corresponds to min, 15."
|
||
::= { error4 3 }
|
||
|
||
error5-time-stamp OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Contains some sort of time stamp indicating when error 5
|
||
occurred. Example time stamps include the actual time the error
|
||
occurred (in seconds since Jan. 1, 1970), and the total engine
|
||
page count. The device POS documents the meaning of the time
|
||
stamp."
|
||
::= { error5 1 }
|
||
|
||
error5-code OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Contains a device specific error code. Each device POS should
|
||
list what errors are logged to the error log and the meaning of
|
||
each supported error code value."
|
||
::= { error5 2 }
|
||
|
||
error5-date-time OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION "This item contains the date and the time at which an error
|
||
occurred. The values returned will be in hexadecimal. If the
|
||
date is 2004-Jul-13 and the time is 03:15 a.m., we get 04 07 0d
|
||
03 0f where,
|
||
04 (hex) - corresponds to the year 2004.
|
||
07 (hex) - corresponds to month, 07
|
||
0d (hex) - corresponds to date, 13
|
||
03 (hex) - corresponds to hour, 3 a.m.
|
||
0f (hex) - corresponds to min, 15."
|
||
::= { error5 3 }
|
||
|
||
error6-time-stamp OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Contains some sort of time stamp indicating when error 6
|
||
occurred. Example time stamps include the actual time the error
|
||
occurred (in seconds since Jan. 1, 1970), and the total engine
|
||
page count. The device POS documents the meaning of the time
|
||
stamp."
|
||
::= { error6 1 }
|
||
|
||
error6-code OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Contains a device specific error code. Each device POS should
|
||
list what errors are logged to the error log and the meaning of
|
||
each supported error code value."
|
||
::= { error6 2 }
|
||
|
||
error6-date-time OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION "This item contains the date and the time at which an error
|
||
occurred. The values returned will be in hexadecimal. If the
|
||
date is 2004-Jul-13 and the time is 03:15 a.m., we get 04 07 0d
|
||
03 0f where,
|
||
04 (hex) - corresponds to the year 2004.
|
||
07 (hex) - corresponds to month, 07
|
||
0d (hex) - corresponds to date, 13
|
||
03 (hex) - corresponds to hour, 3 a.m.
|
||
0f (hex) - corresponds to min, 15."
|
||
::= { error6 3 }
|
||
|
||
error7-time-stamp OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Contains some sort of time stamp indicating when error 7
|
||
occurred. Example time stamps include the actual time the error
|
||
occurred (in seconds since Jan. 1, 1970), and the total engine
|
||
page count. The device POS documents the meaning of the time
|
||
stamp."
|
||
::= { error7 1 }
|
||
|
||
error7-code OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Contains a device specific error code. Each device POS should
|
||
list what errors are logged to the error log and the meaning of
|
||
each supported error code value."
|
||
::= { error7 2 }
|
||
|
||
error7-date-time OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION "This item contains the date and the time at which an error
|
||
occurred. The values returned will be in hexadecimal. If the
|
||
date is 2004-Jul-13 and the time is 03:15 a.m., we get 04 07 0d
|
||
03 0f where,
|
||
04 (hex) - corresponds to the year 2004.
|
||
07 (hex) - corresponds to month, 07
|
||
0d (hex) - corresponds to date, 13
|
||
03 (hex) - corresponds to hour, 3 a.m.
|
||
0f (hex) - corresponds to min, 15."
|
||
::= { error7 3 }
|
||
|
||
error8-time-stamp OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Contains some sort of time stamp indicating when error 8
|
||
occurred. Example time stamps include the actual time the error
|
||
occurred (in seconds since Jan. 1, 1970), and the total engine
|
||
page count. The device POS documents the meaning of the time
|
||
stamp."
|
||
::= { error8 1 }
|
||
|
||
error8-code OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Contains a device specific error code. Each device POS should
|
||
list what errors are logged to the error log and the meaning of
|
||
each supported error code value."
|
||
::= { error8 2 }
|
||
|
||
error8-date-time OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION "This item contains the date and the time at which an error
|
||
occurred. The values returned will be in hexadecimal. If the
|
||
date is 2004-Jul-13 and the time is 03:15 a.m., we get 04 07 0d
|
||
03 0f where,
|
||
04 (hex) - corresponds to the year 2004.
|
||
07 (hex) - corresponds to month, 07
|
||
0d (hex) - corresponds to date, 13
|
||
03 (hex) - corresponds to hour, 3 a.m.
|
||
0f (hex) - corresponds to min, 15."
|
||
::= { error8 3 }
|
||
|
||
error9-time-stamp OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Contains some sort of time stamp indicating when error 9
|
||
occurred. Example time stamps include the actual time the error
|
||
occurred (in seconds since Jan. 1, 1970), and the total engine
|
||
page count. The device POS documents the meaning of the time
|
||
stamp."
|
||
::= { error9 1 }
|
||
|
||
error9-code OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Contains a device specific error code. Each device POS should
|
||
list what errors are logged to the error log and the meaning of
|
||
each supported error code value."
|
||
::= { error9 2 }
|
||
|
||
error9-date-time OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION "This item contains the date and the time at which an error
|
||
occurred. The values returned will be in hexadecimal. If the
|
||
date is 2004-Jul-13 and the time is 03:15 a.m., we get 04 07 0d
|
||
03 0f where,
|
||
04 (hex) - corresponds to the year 2004.
|
||
07 (hex) - corresponds to month, 07
|
||
0d (hex) - corresponds to date, 13
|
||
03 (hex) - corresponds to hour, 3 a.m.
|
||
0f (hex) - corresponds to min, 15."
|
||
::= { error9 3 }
|
||
|
||
error10-time-stamp OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Contains some sort of time stamp indicating when error 10
|
||
occurred. Example time stamps include the actual time the error
|
||
occurred (in seconds since Jan. 1, 1970), and the total engine
|
||
page count. The device POS documents the meaning of the time
|
||
stamp."
|
||
::= { error10 1 }
|
||
|
||
error10-code OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Contains a device specific error code. Each device POS should
|
||
list what errors are logged to the error log and the meaning of
|
||
each supported error code value."
|
||
::= { error10 2 }
|
||
|
||
error10-date-time OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION "This item contains the date and the time at which an error
|
||
occurred. The values returned will be in hexadecimal. If the
|
||
date is 2004-Jul-13 and the time is 03:15 a.m., we get 04 07 0d
|
||
03 0f where,
|
||
04 (hex) - corresponds to the year 2004.
|
||
07 (hex) - corresponds to month, 07
|
||
0d (hex) - corresponds to date, 13
|
||
03 (hex) - corresponds to hour, 3 a.m.
|
||
0f (hex) - corresponds to min, 15."
|
||
::= { error10 3 }
|
||
|
||
error11-time-stamp OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Contains some sort of time stamp indicating when error 11
|
||
occurred. Example time stamps include the actual time the error
|
||
occurred (in seconds since Jan. 1, 1970), and the total engine
|
||
page count. The device POS documents the meaning of the time
|
||
stamp."
|
||
::= { error11 1 }
|
||
|
||
error11-code OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Contains a device specific error code. Each device POS should
|
||
list what errors are logged to the error log and the meaning of
|
||
each supported error code value."
|
||
::= { error11 2 }
|
||
|
||
error11-date-time OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION "This item contains the date and the time at which an error
|
||
occurred. The values returned will be in hexadecimal. If the
|
||
date is 2004-Jul-13 and the time is 03:15 a.m., we get 04 07 0d
|
||
03 0f where,
|
||
04 (hex) - corresponds to the year 2004.
|
||
07 (hex) - corresponds to month, 07
|
||
0d (hex) - corresponds to date, 13
|
||
03 (hex) - corresponds to hour, 3 a.m.
|
||
0f (hex) - corresponds to min, 15."
|
||
::= { error11 3 }
|
||
|
||
error12-time-stamp OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Contains some sort of time stamp indicating when error 12
|
||
occurred. Example time stamps include the actual time the error
|
||
occurred (in seconds since Jan. 1, 1970), and the total engine
|
||
page count. The device POS documents the meaning of the time
|
||
stamp."
|
||
::= { error12 1 }
|
||
|
||
error12-code OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Contains a device specific error code. Each device POS should
|
||
list what errors are logged to the error log and the meaning of
|
||
each supported error code value."
|
||
::= { error12 2 }
|
||
|
||
error12-date-time OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION "This item contains the date and the time at which an error
|
||
occurred. The values returned will be in hexadecimal. If the
|
||
date is 2004-Jul-13 and the time is 03:15 a.m., we get 04 07 0d
|
||
03 0f where,
|
||
04 (hex) - corresponds to the year 2004.
|
||
07 (hex) - corresponds to month, 07
|
||
0d (hex) - corresponds to date, 13
|
||
03 (hex) - corresponds to hour, 3 a.m.
|
||
0f (hex) - corresponds to min, 15."
|
||
::= { error12 3 }
|
||
|
||
error13-time-stamp OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Contains some sort of time stamp indicating when error 13
|
||
occurred. Example time stamps include the actual time the error
|
||
occurred (in seconds since Jan. 1, 1970), and the total engine
|
||
page count. The device POS documents the meaning of the time
|
||
stamp."
|
||
::= { error13 1 }
|
||
|
||
error13-code OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Contains a device specific error code. Each device POS should
|
||
list what errors are logged to the error log and the meaning of
|
||
each supported error code value."
|
||
::= { error13 2 }
|
||
|
||
error13-date-time OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION "This item contains the date and the time at which an error
|
||
occurred. The values returned will be in hexadecimal. If the
|
||
date is 2004-Jul-13 and the time is 03:15 a.m., we get 04 07 0d
|
||
03 0f where,
|
||
04 (hex) - corresponds to the year 2004.
|
||
07 (hex) - corresponds to month, 07
|
||
0d (hex) - corresponds to date, 13
|
||
03 (hex) - corresponds to hour, 3 a.m.
|
||
0f (hex) - corresponds to min, 15."
|
||
::= { error13 3 }
|
||
|
||
error14-time-stamp OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Contains some sort of time stamp indicating when error 14
|
||
occurred. Example time stamps include the actual time the error
|
||
occurred (in seconds since Jan. 1, 1970), and the total engine
|
||
page count. The device POS documents the meaning of the time
|
||
stamp."
|
||
::= { error14 1 }
|
||
|
||
error14-code OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Contains a device specific error code. Each device POS should
|
||
list what errors are logged to the error log and the meaning of
|
||
each supported error code value."
|
||
::= { error14 2 }
|
||
|
||
error14-date-time OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION "This item contains the date and the time at which an error
|
||
occurred. The values returned will be in hexadecimal. If the
|
||
date is 2004-Jul-13 and the time is 03:15 a.m., we get 04 07 0d
|
||
03 0f where,
|
||
04 (hex) - corresponds to the year 2004.
|
||
07 (hex) - corresponds to month, 07
|
||
0d (hex) - corresponds to date, 13
|
||
03 (hex) - corresponds to hour, 3 a.m.
|
||
0f (hex) - corresponds to min, 15."
|
||
::= { error14 3 }
|
||
|
||
error15-time-stamp OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Contains some sort of time stamp indicating when error 15
|
||
occurred. Example time stamps include the actual time the error
|
||
occurred (in seconds since Jan. 1, 1970), and the total engine
|
||
page count. The device POS documents the meaning of the time
|
||
stamp."
|
||
::= { error15 1 }
|
||
|
||
error15-code OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Contains a device specific error code. Each device POS should
|
||
list what errors are logged to the error log and the meaning of
|
||
each supported error code value."
|
||
::= { error15 2 }
|
||
|
||
error15-date-time OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION "This item contains the date and the time at which an error
|
||
occurred. The values returned will be in hexadecimal. If the
|
||
date is 2004-Jul-13 and the time is 03:15 a.m., we get 04 07 0d
|
||
03 0f where,
|
||
04 (hex) - corresponds to the year 2004.
|
||
07 (hex) - corresponds to month, 07
|
||
0d (hex) - corresponds to date, 13
|
||
03 (hex) - corresponds to hour, 3 a.m.
|
||
0f (hex) - corresponds to min, 15."
|
||
::= { error15 3 }
|
||
|
||
printed-media-simplex-count OBJECT-TYPE
|
||
SYNTAX INTEGER(0..930576247)
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Total number of simplex pages printed in this media size.
|
||
Additional information:
|
||
The 5 usage (simplex/duplex count, simplex/duplex click
|
||
charge and paper size total) objects described here and
|
||
below detail the usage for the printer for each paper
|
||
size defined in the PCL Implementor's Guide and in the
|
||
Media Size Table in the hpmib.txt. The OID binding is
|
||
based on the click attribute and paper size.
|
||
For example:
|
||
The format for the OID is as follows:
|
||
3.4.1.5.x.y
|
||
<-----> | |
|
||
| | \
|
||
/ | paper size
|
||
/ \
|
||
PRINTER-CLICK_TOTALS ROOT \
|
||
OID click attribute 1..5
|
||
x values are 1..5:
|
||
1) simplex count
|
||
2) simplex click charge
|
||
3) duplex count
|
||
4) duplex click charge
|
||
5) printer or scanner paper size total (i.e. depends if the
|
||
root OID is referrring to the printer or scanner).
|
||
y : paper size as defined in the Media Size Table in the
|
||
hpmib.txt "
|
||
::= { printed-media-usage 1 }
|
||
|
||
printed-media-duplex-count OBJECT-TYPE
|
||
SYNTAX INTEGER(0..930576247)
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Total number of duplex pages printed in this media size."
|
||
::= { printed-media-usage 3 }
|
||
|
||
usage-printer-total-charge OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Total printer charge for all paper sizes printed."
|
||
::= { printer-accounting 2 }
|
||
|
||
usage-average-toner-coverage OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Reports the average toner area coverage of all pages printed
|
||
over the life of the device. Counts pixels on each page,
|
||
divides pixel count by pixels possible on a page to give the
|
||
percentage of coverage, and keeps a rolling average percent
|
||
weighted by area printed."
|
||
::= { printer-accounting 3 }
|
||
|
||
usage-staple-count OBJECT-TYPE
|
||
SYNTAX INTEGER(0..930576247)
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Total number of staples used."
|
||
::= { printer-accounting 4 }
|
||
|
||
usage-printer-mono-total-charge OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Total printer charge for all paper sizes printed in monochrome
|
||
only.
|
||
Additional information:
|
||
This is the total charge over the range of all
|
||
supported media sizes for duplex and simplex mono
|
||
pages."
|
||
::= { printer-accounting 12 }
|
||
|
||
usage-printer-color-total-charge OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Total printer charge for all paper sizes printed in color
|
||
only.
|
||
Additional information:
|
||
This is the total charge over the range of all
|
||
supported media sizes for duplex and simplex color
|
||
pages."
|
||
::= { printer-accounting 13 }
|
||
|
||
print-meter-equivalent-impression-count OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"This object reports the equivalent number of impressions by
|
||
category and media size for all pages printed on this device.
|
||
All printed impressions are normalized to a Letter/A4 sheet of
|
||
media by dividing the area of the sheet by that of a Letter/A4
|
||
sheet of media. This is a doubly indexed array object where the
|
||
first OID binding is the impression category and the second OID
|
||
binding is the data source for the printed impression. The
|
||
possible categories are: \\
|
||
1 = Monochrome\\
|
||
2 = Color\\
|
||
3 = Composite Black\\
|
||
4 = General Office Accent\\
|
||
5 = General Office Color\\
|
||
6 = Professional Accent\\
|
||
7 = Professional Color\\
|
||
8 = Presentation Accent\\
|
||
9 = Presentation Color\\
|
||
10 = MAX DPI Accent\\
|
||
11 = MAX DPI Color\\
|
||
The possible media sizes are defined in the PCL
|
||
Implementers Guide and in the Media Size Table near
|
||
the end of this MIB.\\
|
||
The possible Data Sources are: \\
|
||
1 = Print (I/O Port or Internal Pages)\\
|
||
2 = Copy (Scanner)\\
|
||
3 = FAX (Modem)\\
|
||
The format for the OID is as follows: 1.1.16.1.44.m.p
|
||
<---------> | | | | \
|
||
| | Data Source / \
|
||
/ \
|
||
Base OID Impression Category The device POS will indicate which
|
||
impression categories and which data sources are
|
||
supported/implemented for a given product."
|
||
::= { printer-accounting 44 }
|
||
|
||
usage-scanner-total-charge OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Total scanner charge or cost for all paper sizes scanned."
|
||
::= { scanner-accounting 2 }
|
||
|
||
printed-media-color-simplex-count OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Total number of color simplex pages printed in this media
|
||
size."
|
||
::= { printed-media-color-usage 1 }
|
||
|
||
printed-media-color-duplex-count OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Total number of color duplex pages printed in this media size."
|
||
::= { printed-media-color-usage 3 }
|
||
|
||
scanner-accessory-adf-sheet-count OBJECT-TYPE
|
||
SYNTAX INTEGER(0..2147483647)
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION "Total number of sheets that have been fed through the Automatic
|
||
Document Feed (ADF) accessory.
|
||
Additional information:
|
||
The Automatic Document Feed (ADF) count is
|
||
incremented each time a sheet feeds through the
|
||
ADF.
|
||
The value will be updated at the end of every
|
||
scan job. "
|
||
::= { settings-scanner 20 }
|
||
|
||
scanner-accessory-flatbed-scan-count OBJECT-TYPE
|
||
SYNTAX INTEGER(0..2147483647)
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION "Total number of scans performed by a flatbed scanner
|
||
accessory.
|
||
Additional information:
|
||
The count is only incremented when a sheet is
|
||
scanned on the FLATBED.
|
||
The return value of this object will reset
|
||
to the lower multiple of 10 at a power cycle.
|
||
The value will be updated at the end of every
|
||
scan job. "
|
||
::= { settings-scanner 21 }
|
||
|
||
scanner-accessory-copy-job-scan-count OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION "This relates to the number of pages scanned for copying. This
|
||
item is incremented by 2 for each sheet scanned through the ADF
|
||
in 2-sided scan mode, and it is incremented by 1 for flatbed
|
||
scans. Scanning for testing and calibration purposes are NOT TO
|
||
BE INCLUDED in this count.
|
||
Additional information:
|
||
The value will be updated at the end of every
|
||
scan job. "
|
||
::= { settings-scanner 61 }
|
||
|
||
scanner-accessory-send-job-scan-count OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION "This relates to the number of pages scanned for fax/send. This
|
||
item is incremented by 2 for each sheet scanned through the ADF
|
||
in 2-sided scan mode, and it is incremented by 1 for flatbed
|
||
scans. Scanning for testing and calibration purposes are NOT TO
|
||
BE INCLUDED in this count.
|
||
Additional information:
|
||
The value will be updated at the end of every
|
||
scan job. "
|
||
::= { settings-scanner 62 }
|
||
|
||
scanner-accessory-total-copy-pages-printed OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION "This relates to the number of copy pages printed on a device.
|
||
The output sheet that is duplexed (made 2- sided) should be
|
||
counted as 2 pages."
|
||
::= { settings-scanner 63 }
|
||
|
||
scan-to-folder-count OBJECT-TYPE
|
||
SYNTAX INTEGER(0..9999999)
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION "The number of scan-to-folder scan jobs.
|
||
Additional information:
|
||
The number of scan-to-folder scan jobs."
|
||
::= { settings-scanner 89 }
|
||
|
||
fax-job-scan-count OBJECT-TYPE
|
||
SYNTAX INTEGER(0..9999999)
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION "The number of fax scan jobs.
|
||
Additional information:
|
||
The number of fax scan jobs."
|
||
::= { settings-scanner 90 }
|
||
|
||
scanner-accessory-total-copy-mono-pages-printed OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"This relates to the number of copy mono pages printed on a
|
||
device.The output sheet that is duplexed (made 2-sided) should
|
||
be counted as 2 pages."
|
||
::= { settings-scanner 122 }
|
||
|
||
scanner-accessory-total-copy-color-pages-printed OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"This relates to the number of copy color pages printed on a
|
||
device.The output sheet that is duplexed (made 2-sided) should
|
||
be counted as 2 pages."
|
||
::= { settings-scanner 123 }
|
||
|
||
pcl-total-page-count OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Total number of PCL pages printed by the device.
|
||
Additional information:
|
||
The page count is incremented when a sheet of media is pulled from an input
|
||
tray. A duplex printed sheet will cause this counter to be incremented by
|
||
two."
|
||
::= { pdl-pcl 5 }
|
||
|
||
postscript-total-page-count OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Total number of PostScript pages printed by the device."
|
||
::= { pdl-postscript 5 }
|
||
|
||
fax-print-page-count OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-write
|
||
STATUS optional
|
||
DESCRIPTION "This object tracks the page count for the pages sent to the
|
||
print engine for fax jobs. In order to write this object
|
||
SERVICE-PASSWORD must be set correctly."
|
||
::= { settings-fax-proc-sub 32 }
|
||
|
||
afax-send-page-count OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-write
|
||
STATUS optional
|
||
DESCRIPTION "Keeps the total number of pages sent successfully via the
|
||
analog fax modem. This count would be synchronised with the
|
||
number of fax jobs sent successfully. The <<hidden>> must
|
||
be set correctly to write this object."
|
||
::= { status-fax-proc-sub 11 }
|
||
|
||
afax-recv-page-count OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-write
|
||
STATUS optional
|
||
DESCRIPTION "Keeps the total number of pages received successfully via the
|
||
analog fax modem. This count would be synchronised with the
|
||
number of fax jobs received successfully. The <<hidden>>
|
||
must be set correctly to write this object."
|
||
::= { status-fax-proc-sub 12 }
|
||
|
||
total-engine-page-count OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-write
|
||
STATUS optional
|
||
DESCRIPTION "Total number of pages printed by the device. POS indicates if
|
||
the total engine page count is kept in NVRAM, and the maximum
|
||
supported value before the page count rolls over to zero."
|
||
::= { status-prt-eng 5 }
|
||
|
||
total-mono-page-count OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION "Total number of black pages printed by the device."
|
||
::= { status-prt-eng 6 }
|
||
|
||
total-color-page-count OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Total number of color pages printed by the device.
|
||
Additional information:
|
||
Any page with one or more color pixels is counted as a color page. Pages that only
|
||
contain black marks are not counted by this object.
|
||
A duplexed sheet of media will cause the counter to be incremented by two."
|
||
::= { status-prt-eng 7 }
|
||
|
||
duplex-page-count OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Total number of sheets of media that have been duplex printed.
|
||
A sheet is counted if it travels through the duplex page path,
|
||
regardless of whether or not marks are made on the page. The
|
||
POS will indicate if the value is kept in NVRAM."
|
||
::= { status-prt-eng 22 }
|
||
|
||
not-ready-tray-empty OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Indicates which trays contain no media causing the device to be
|
||
not ready. Some devices may treat tray missing as a tray empty
|
||
condition.
|
||
Additional information:
|
||
The input trays designated by the bits of
|
||
this collection include the standard input tray(s) plus the
|
||
additional tray(s) attached to the printer."
|
||
::= { status-intray 2 }
|
||
|
||
tray1-media-size-loaded OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
eAnySize(32765),
|
||
eUSExecutive(1),
|
||
eUSLetter(2),
|
||
eUSLegal(3),
|
||
eFoolscap(10),
|
||
eLegal216x340(127),
|
||
eStatement(15),
|
||
eIndexCard3x5(78),
|
||
eIndexCard4x6(74),
|
||
eIndexCard5x7(122),
|
||
eIndexCard5x8(75),
|
||
eISOandJISA4(26),
|
||
eISOandJISA5(25),
|
||
eISOandJISA6(24),
|
||
eJISB5(45),
|
||
eJISB6(44),
|
||
ePhotoLSizeCard(121),
|
||
ePhoto10x15(118),
|
||
ePRC16K195X270(34),
|
||
ePRC16K184X260(89),
|
||
eROC16K(17),
|
||
eJapansePostcardSingle(71),
|
||
eJapanseOufuku148x200(328),
|
||
eCommercial10(81),
|
||
eMonarch(80),
|
||
eInternationalDL(90),
|
||
eInternationalB5(100),
|
||
eInternationalC5(91),
|
||
eInternationalC6(92),
|
||
eJapanseEnvLong3(110),
|
||
eJapanseEnvLong4(111),
|
||
eCustom(101)
|
||
}
|
||
ACCESS read-write
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Returns the media size that is currently configuredconfigured
|
||
in tray #1. This object can be set to indicate the media size
|
||
currently loaded, if the printer supports input trays that can
|
||
not sense the media size."
|
||
::= { intray1 1 }
|
||
|
||
tray1-media-name OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
ACCESS read-write
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Contains a string identifying the media that is currently
|
||
loaded in tray #1. The media name string is the name associated
|
||
with the loaded media. The strings identifying different media
|
||
are user defined. Examples media name strings include 'HR
|
||
Company LetterHead', '1091 Invoice Form', 'White Bond',
|
||
'Canary', and 'White Recycled'."
|
||
::= { intray1 4 }
|
||
|
||
tray1-custom-media-width OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Width of media (in decipoints) loaded in tray 1."
|
||
::= { intray1 10 }
|
||
|
||
tray1-custom-media-length OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Length of media (in decipoints) loaded in tray 1."
|
||
::= { intray1 11 }
|
||
|
||
tray1-type OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
eTray(1),
|
||
eManualRoll(2),
|
||
eArss(3),
|
||
eManualSheet(4)
|
||
}
|
||
ACCESS read-write
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Indicates the type of input media support installed. eTray (1)
|
||
if the paper source is a tray eManualRoll (2) if the paper
|
||
source is a manually loaded roll eArss (3) if the paper source
|
||
is an anutomatically loaded roll (ARSS) eManualSheet (4) if the
|
||
paper source is only for a manually loaded single sheet"
|
||
::= { intray1 17 }
|
||
|
||
tray1-media-key OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Contains the media key (index) in the database."
|
||
::= { intray1 20 }
|
||
|
||
tray2-media-size-loaded OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
eUSExecutive(1),
|
||
eUSLetter(2),
|
||
eStatement(15),
|
||
eISOandJISA4(26),
|
||
eISOandJISA5(25),
|
||
eJISB5(45),
|
||
ePRC16K195X270(34),
|
||
ePRC16K184X260(89),
|
||
eROC16K(17),
|
||
eCommercial10(81),
|
||
eInternationalDL(90),
|
||
eInternationalB5(100),
|
||
eInternationalC5(91),
|
||
eJapanseEnvLong3(110),
|
||
eCustom(101)
|
||
}
|
||
ACCESS read-write
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Returns the media size that is currently configured in tray #2."
|
||
::= { intray2 1 }
|
||
|
||
tray2-media-name OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
ACCESS read-write
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Contains a string identifying the media that is currently
|
||
loaded in tray 2. See TRAY1-MEDIA-NAME for a complete
|
||
description."
|
||
::= { intray2 4 }
|
||
|
||
tray2-custom-media-width OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Width of media (in decipoints) loaded in tray 2."
|
||
::= { intray2 10 }
|
||
|
||
tray2-custom-media-length OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Length of media (in decipoints) loaded in tray 2."
|
||
::= { intray2 11 }
|
||
|
||
tray2-type OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
eTray(1),
|
||
eManualRoll(2),
|
||
eArss(3),
|
||
eManualSheet(4)
|
||
}
|
||
ACCESS read-write
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Indicates the type of input media support installed. eTray (1)
|
||
if the paper source is a tray eManualRoll (2) if the paper
|
||
source is a manually loaded roll eArss (3) if the paper source
|
||
is an anutomatically loaded roll (ARSS) eManualSheet (4) if the
|
||
paper source is only for a manually loaded single sheet"
|
||
::= { intray2 17 }
|
||
|
||
tray2-media-key OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Contains the media key (index) in the database."
|
||
::= { intray2 20 }
|
||
|
||
tray3-media-size-loaded OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
eUSExecutive(1),
|
||
eUSLetter(2),
|
||
eUSLegal(3),
|
||
eStatement(15),
|
||
eFoolscap(10),
|
||
eLegal216x340(127),
|
||
eISOandJISA4(26),
|
||
eISOandJISA5(25),
|
||
eJISB5(45),
|
||
ePRC16K195X270(34),
|
||
ePRC16K184X260(89),
|
||
eROC16K(17),
|
||
eCustom(101)
|
||
}
|
||
ACCESS read-write
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Returns the media size that is currently configured in tray #3."
|
||
::= { intray3 1 }
|
||
|
||
tray3-media-name OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
ACCESS read-write
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Contains a string identifying the media that is currently
|
||
loaded in tray 3. See TRAY1-MEDIA-NAME for a complete
|
||
description."
|
||
::= { intray3 4 }
|
||
|
||
tray3-custom-media-width OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Width of media (in decipoints) loaded in tray 3."
|
||
::= { intray3 10 }
|
||
|
||
tray3-custom-media-length OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Length of media (in decipoints) loaded in tray 3."
|
||
::= { intray3 11 }
|
||
|
||
tray3-type OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
eTray(1),
|
||
eManualRoll(2),
|
||
eArss(3),
|
||
eManualSheet(4)
|
||
}
|
||
ACCESS read-write
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Indicates the type of input media support installed. eTray (1)
|
||
if the paper source is a tray eManualRoll (2) if the paper
|
||
source is a manually loaded roll eArss (3) if the paper source
|
||
is an anutomatically loaded roll (ARSS) eManualSheet (4) if the
|
||
paper source is only for a manually loaded single sheet"
|
||
::= { intray3 17 }
|
||
|
||
tray3-media-key OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Contains the media key (index) in the database."
|
||
::= { intray3 20 }
|
||
|
||
tray5-media-size-loaded OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
eUSExecutive(1),
|
||
eUSLetter(2),
|
||
eUSLegal(3),
|
||
eStatement(15),
|
||
eFoolscap(10),
|
||
eLegal216x340(127),
|
||
eISOandJISA4(26),
|
||
eISOandJISA5(25),
|
||
eJISB5(45),
|
||
ePRC16K195X270(34),
|
||
ePRC16K184X260(89),
|
||
eROC16K(17),
|
||
eCustom(101)
|
||
}
|
||
ACCESS read-write
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Returns the media size that is currently configured in tray #4."
|
||
::= { intray5 1 }
|
||
|
||
tray5-media-name OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
ACCESS read-write
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Contains a string identifying the media that is currently
|
||
loaded in tray 4. See TRAY1-MEDIA-NAME for a complete
|
||
description."
|
||
::= { intray5 4 }
|
||
|
||
tray5-custom-media-width OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Width of media (in decipoints) loaded in tray 4."
|
||
::= { intray5 10 }
|
||
|
||
tray5-custom-media-length OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Length of media (in decipoints) loaded in tray 4."
|
||
::= { intray5 11 }
|
||
|
||
tray5-type OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
eTray(1),
|
||
eManualRoll(2),
|
||
eArss(3),
|
||
eManualSheet(4)
|
||
}
|
||
ACCESS read-write
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Indicates the type of input media support installed. eTray (1)
|
||
if the paper source is a tray eManualRoll (2) if the paper
|
||
source is a manually loaded roll eArss (3) if the paper source
|
||
is an anutomatically loaded roll (ARSS) eManualSheet (4) if the
|
||
paper source is only for a manually loaded single sheet"
|
||
::= { intray5 17 }
|
||
|
||
tray5-media-key OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Contains the media key (index) in the database."
|
||
::= { intray5 20 }
|
||
|
||
media-names-enabled OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
ACCESS read-write
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"The value of this object controls whish of the MEDIAx-NAME
|
||
objects are supported. Of a bit is set to zero then the attempt
|
||
to get or set the corresponding MEDIAx-NAME objects will return
|
||
<ErrorUnknownObjectIdentifier>"
|
||
::= { settings-print-media 3 }
|
||
|
||
media1-name OBJECT-TYPE
|
||
SYNTAX DisplayString (SIZE(1..24))
|
||
ACCESS read-write
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Media 1 name.
|
||
Additional information:
|
||
The symbol set for this string is Roman-8."
|
||
::= { media1 1 }
|
||
|
||
media2-name OBJECT-TYPE
|
||
SYNTAX DisplayString (SIZE(1..24))
|
||
ACCESS read-write
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Media 2 name.
|
||
Additional information:
|
||
See MEDIA1-NAME."
|
||
::= { media2 1 }
|
||
|
||
media3-name OBJECT-TYPE
|
||
SYNTAX DisplayString (SIZE(1..24))
|
||
ACCESS read-write
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Media 3 name.
|
||
Additional information:
|
||
See MEDIA1-NAME."
|
||
::= { media3 1 }
|
||
|
||
media4-name OBJECT-TYPE
|
||
SYNTAX DisplayString (SIZE(1..24))
|
||
ACCESS read-write
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Media 4 name.
|
||
Additional information:
|
||
See MEDIA1-NAME."
|
||
::= { media4 1 }
|
||
|
||
media5-name OBJECT-TYPE
|
||
SYNTAX DisplayString (SIZE(1..24))
|
||
ACCESS read-write
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Media 5 name.
|
||
Additional information:
|
||
See MEDIA1-NAME."
|
||
::= { media5 1 }
|
||
|
||
media6-name OBJECT-TYPE
|
||
SYNTAX DisplayString (SIZE(1..24))
|
||
ACCESS read-write
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Media 6 name.
|
||
Additional information:
|
||
See MEDIA1-NAME."
|
||
::= { media6 1 }
|
||
|
||
media7-name OBJECT-TYPE
|
||
SYNTAX DisplayString (SIZE(1..24))
|
||
ACCESS read-write
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Media 7 name.
|
||
Additional information:
|
||
See MEDIA1-NAME."
|
||
::= { media7 1 }
|
||
|
||
media8-name OBJECT-TYPE
|
||
SYNTAX DisplayString (SIZE(1..24))
|
||
ACCESS read-write
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Media 8 name.
|
||
Additional information:
|
||
See MEDIA1-NAME."
|
||
::= { media8 1 }
|
||
|
||
media9-name OBJECT-TYPE
|
||
SYNTAX DisplayString (SIZE(1..24))
|
||
ACCESS read-write
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Media 9 name.
|
||
Additional information:
|
||
See MEDIA1-NAME."
|
||
::= { media9 1 }
|
||
|
||
media10-name OBJECT-TYPE
|
||
SYNTAX DisplayString (SIZE(1..24))
|
||
ACCESS read-write
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Media 10 name.
|
||
Additional information:
|
||
See MEDIA1-NAME."
|
||
::= { media10 1 }
|
||
|
||
media11-name OBJECT-TYPE
|
||
SYNTAX DisplayString (SIZE(1..24))
|
||
ACCESS read-write
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Media 11 name.
|
||
Additional information:
|
||
See MEDIA1-NAME."
|
||
::= { media11 1 }
|
||
|
||
media12-name OBJECT-TYPE
|
||
SYNTAX DisplayString (SIZE(1..24))
|
||
ACCESS read-write
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Media 12 name.
|
||
Additional information:
|
||
See MEDIA1-NAME."
|
||
::= { media12 1 }
|
||
|
||
media13-name OBJECT-TYPE
|
||
SYNTAX DisplayString (SIZE(1..24))
|
||
ACCESS read-write
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Media 13 name.
|
||
Additional information:
|
||
See MEDIA1-NAME."
|
||
::= { media13 1 }
|
||
|
||
media14-name OBJECT-TYPE
|
||
SYNTAX DisplayString (SIZE(1..24))
|
||
ACCESS read-write
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Media 14 name.
|
||
Additional information:
|
||
See MEDIA1-NAME."
|
||
::= { media14 1 }
|
||
|
||
media15-name OBJECT-TYPE
|
||
SYNTAX DisplayString (SIZE(1..24))
|
||
ACCESS read-write
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Media 15 name.
|
||
Additional information:
|
||
The maximum supported string length is 24
|
||
bytes. If the user entered string is too long,
|
||
the device will store the first 24 bytes and
|
||
return the <noError> status.
|
||
See CAUTION statement under Product Specific Use."
|
||
::= { media15 1 }
|
||
|
||
media16-name OBJECT-TYPE
|
||
SYNTAX DisplayString (SIZE(1..24))
|
||
ACCESS read-write
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Media 16 name.
|
||
Additional information:
|
||
See MEDIA15-NAME."
|
||
::= { media16 1 }
|
||
|
||
media17-name OBJECT-TYPE
|
||
SYNTAX DisplayString (SIZE(1..24))
|
||
ACCESS read-write
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Media 17 name.
|
||
Additional information:
|
||
See MEDIA15-NAME."
|
||
::= { media17 1 }
|
||
|
||
media18-name OBJECT-TYPE
|
||
SYNTAX DisplayString (SIZE(1..24))
|
||
ACCESS read-write
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Media 18 name.
|
||
Additional information:
|
||
See MEDIA15-NAME."
|
||
::= { media18 1 }
|
||
|
||
media19-name OBJECT-TYPE
|
||
SYNTAX DisplayString (SIZE(1..24))
|
||
ACCESS read-write
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Media 19 name.
|
||
Additional information:
|
||
See MEDIA15-NAME."
|
||
::= { media19 1 }
|
||
|
||
consumable-status-cartridge-model OBJECT-TYPE
|
||
SYNTAX DisplayString (SIZE(0..24))
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"This object is used to read the cartridge model number
|
||
associated with this consumable.
|
||
Additional information:
|
||
This object will only exist for Authentic HP consumables.
|
||
If the cartridge is deemed to be NonHP, then this object
|
||
will not exist."
|
||
::= { consumable-status 1 }
|
||
|
||
consumable-status-manufacturing-date OBJECT-TYPE
|
||
SYNTAX DisplayString (SIZE(0..24))
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"This object is used to report the date on which this consumable
|
||
was manufactured. The format of the string is 'YYYYMMDD', where
|
||
YYYY is the year, MM is the month (1-12), and DD is the day
|
||
(1-31).
|
||
Additional information:
|
||
This object will only exist for Authentic HP consumables.
|
||
If the cartridge is deemed to be NonHP, then this object
|
||
will not exist."
|
||
::= { consumable-status 2 }
|
||
|
||
consumable-status-serial-number OBJECT-TYPE
|
||
SYNTAX DisplayString (SIZE(0..24))
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"This object is used to report the serial number for this
|
||
consumable.
|
||
Additional information:
|
||
This object will only exist for Authentic HP consumables.
|
||
If the cartridge is deemed to be NonHP, then this object
|
||
will not exist."
|
||
::= { consumable-status 3 }
|
||
|
||
consumable-status-first-install-date OBJECT-TYPE
|
||
SYNTAX DisplayString (SIZE(0..24))
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"This object is used to report the date on which this consumable
|
||
was first installed. The format of the string is 'YYYYMMDD'.
|
||
Where:
|
||
YYYY is the year.
|
||
MM is the month (1-12).
|
||
DD is the day (1-31).
|
||
The device POS needs to indicate what will be written in the
|
||
event the printer does not have a real time clock.
|
||
Additional information:
|
||
This object will only exist for Authentic HP consumables.
|
||
If the cartridge is deemed to be NonHP, then this object
|
||
will not exist. For printers without internal clocks, the
|
||
date will always be 20000101."
|
||
::= { consumable-status 8 }
|
||
|
||
npSysModelNumber OBJECT-TYPE
|
||
SYNTAX OCTET STRING ( SIZE ( 6 ) )
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The HP model number of the device."
|
||
::= { npSys 10 }
|
||
|
||
npSysCardServices1 OBJECT-TYPE
|
||
SYNTAX Integer32
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"This object is a bitmap showing what services are available
|
||
on the card.
|
||
Bit 0 - IPX/SPX/NCP protocol stack
|
||
Bit 1 - IP/TCP protocol stack
|
||
Bit 2 - LLC/DLC protocol stack
|
||
Bit 3 - Ethertalk protocol stack
|
||
Bit 4 - IPv6 protocol stack
|
||
Bit 5 - IPSec protocol stack
|
||
Bits 6 - 11 Reserved
|
||
Bit 12 - LPD print services
|
||
Bit 13 - FTP print services
|
||
Bit 14 - Port 9100 print services
|
||
Bit 15 - IPP print services
|
||
Bits 16 - 23 Reserved
|
||
Bit 24 - Queue Server Bindery
|
||
Bit 25 - Queue Server NDS
|
||
Bit 26 - Remote Printer
|
||
Bit 27 - SPX Direct Mode
|
||
Bit 28 - DLC Print Services
|
||
Bit 29 - EtherTalk Print Services
|
||
Bits 30 - 31 Reserved"
|
||
::= { npSys 16 }
|
||
|
||
npSysCardServices2 OBJECT-TYPE
|
||
SYNTAX Integer32
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"This object is a bitmap showing what services are available
|
||
on the card.
|
||
Bit 0 - XIP2
|
||
Bit 1 - PML Get/Set
|
||
Bit 2 - PML Traps
|
||
Bit 3 - Scan to Web Browser
|
||
Bit 4 - Scan to Email
|
||
Bit 5 - MFP Scan Support
|
||
Bits 6 - 11 Reserved
|
||
Bit 12 - Telnet API
|
||
Bit 13 - Web API
|
||
Bit 14 - SNMP V2
|
||
Bit 15 - SNMP Traps
|
||
Bit 16 - Download
|
||
Bit 17 - TFTP
|
||
Bit 18 - RCFG
|
||
Bit 19 - SLP
|
||
Bit 20 - Syslog
|
||
Bit 21 - DHCP
|
||
Bit 22 - BOOTP
|
||
Bit 23 - RARP
|
||
Bit 24 - SNMP V3
|
||
Bit 25 - SSL Functionality
|
||
Bit 26 - Auto IP
|
||
Bit 27 - SNMP V3 SHA-1 & AES-128 support.
|
||
Bits 28 - 31 Reserved"
|
||
::= { npSys 17 }
|
||
|
||
npSysCardServices3 OBJECT-TYPE
|
||
SYNTAX Integer32
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"This object is a bitmap showing what services are available
|
||
on the card.
|
||
Bit 0 - 100T
|
||
Bit 1 - Token Ring 802.5
|
||
Bit 2 - 802.11b
|
||
Bit 3 - 80211.a
|
||
Bit 4 - Bluetooth
|
||
Bits 5 - 11 Reserved
|
||
Bit 12 - EIO. For embedded Jetdirect this bit will be 1.
|
||
Bit 13 - LIO
|
||
Bit 14 - USB
|
||
Bit 15 - Firewire
|
||
Bit 16 - TCP Download
|
||
Bits 17 - 31 Reserved"
|
||
::= { npSys 22 }
|
||
|
||
npCfgSource OBJECT-TYPE
|
||
SYNTAX INTEGER { manual-one ( 1 ) , bootp-two ( 2 ) , manual-three ( 3 ) , bootp-four ( 4 ) , dhcp ( 5 ) , not-configured ( 6 ) , default-config ( 7 ) , rarp ( 8 ) , read-only ( 9 ) , auto-ip ( 10 ) }
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"This object indicates how the device obtained its IP configuration."
|
||
::= { npCfg 1 }
|
||
|
||
npCfgYiaddr OBJECT-TYPE
|
||
SYNTAX IpAddress
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The IP address assigned to the card from the BOOTP reply
|
||
yiaddr field."
|
||
::= { npCfg 2 }
|
||
|
||
npCfgSiaddr OBJECT-TYPE
|
||
SYNTAX IpAddress
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The IP address of the TFTP server from the BOOTP reply
|
||
siaddr field."
|
||
::= { npCfg 3 }
|
||
|
||
npCfgLogServer OBJECT-TYPE
|
||
SYNTAX IpAddress
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The IP address of the Syslog Server. If set via BOOTP (Tag: 7 field,
|
||
lg=<ipaddress> ) then SNMP set will fail. If not set via BOOTP then SNMP set
|
||
will succeed. Value saved across warm boot power cycles. BOOTP will always
|
||
overwrite SNMP set values."
|
||
::= { npCfg 5 }
|
||
|
||
npCfgSubnetMask OBJECT-TYPE
|
||
SYNTAX IpAddress
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The subnet mask associated with the IP address of this card."
|
||
::= { npCfg 12 }
|
||
|
||
npCfgDefaultGateway OBJECT-TYPE
|
||
SYNTAX IpAddress
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"This variable contains the IP address of the default router for this
|
||
card."
|
||
::= { npCfg 13 }
|
||
|
||
npCfgDomainName OBJECT-TYPE
|
||
SYNTAX OCTET STRING ( SIZE ( 0 .. 255 ) )
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The print server domain name."
|
||
::= { npCfg 16 }
|
||
|
||
npCfgIPP OBJECT-TYPE
|
||
SYNTAX Integer32
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Below are the different values accepted by this OID.
|
||
0 - Disable IPP and IPP-S
|
||
1 - Enable IPP and IPP-S
|
||
2 - Enable IPP-S only
|
||
3 - Enable IPP only
|
||
"
|
||
::= { npCfg 18 }
|
||
|
||
npCfgDNSNameServerId OBJECT-TYPE
|
||
SYNTAX IpAddress
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"IP address of Primary DNS name-server."
|
||
::= { npCfg 21 }
|
||
|
||
npCfgWINSNameServerIdPri OBJECT-TYPE
|
||
SYNTAX IpAddress
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Primary name server for NetBIOS over TCP/IP."
|
||
::= { npCfg 22 }
|
||
|
||
npCfgWINSNameServerIdSec OBJECT-TYPE
|
||
SYNTAX IpAddress
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Secondary name server for NetBIOS over TCP/IP."
|
||
::= { npCfg 23 }
|
||
|
||
npCfgPasswd1 OBJECT-TYPE
|
||
SYNTAX DisplayString
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Password for root or administrator. Get request returns
|
||
either 'SET' or 'NOT_SET'."
|
||
::= { npCfg 29 }
|
||
|
||
npCfgLinkType OBJECT-TYPE
|
||
SYNTAX INTEGER { autoNegotiate ( 1 ) , full10T ( 2 ) , half10T ( 3 ) , full100T ( 4 ) , half100T ( 5 ) , auto100T ( 6 ) , full1000T ( 7 ) }
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Network link speed and communication mode."
|
||
::= { npCfg 35 }
|
||
|
||
npCfgSnmpDefaultReadCmnty OBJECT-TYPE
|
||
SYNTAX Integer32 ( 0 .. 1 )
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Controls Default Read Community Name access.
|
||
(0) = Disabled, i.e., default get community names FAIL to access target.
|
||
(1) = Enabled, i.e., default get community names SUCCEED to access target."
|
||
::= { npCfg 40 }
|
||
|
||
npCfgBonjourServiceName OBJECT-TYPE
|
||
SYNTAX OCTET STRING ( SIZE ( 0 .. 63 ) )
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The name by which all the Jetdirect services will be advertised by
|
||
Multicast Domain Name System (Bonjour). Must set a non empty string"
|
||
::= { npCfg 44 }
|
||
|
||
npCfgBonjourHighestPriorityService OBJECT-TYPE
|
||
SYNTAX INTEGER { p9100-Printing ( 1 ) , IPP-Printing ( 2 ) , lPD-Printing-RAW ( 3 ) , lPD-Printing-TEXT ( 4 ) , lPD-Printing-AUTO ( 5 ) , lPD-Printing-BINPS ( 6 ) , lPD-Printing-Queue5 ( 7 ) , lPD-Printing-Queue6 ( 8 ) , lPD-Printing-Queue7 ( 9 ) , lPD-Printing-Queue8 ( 10 ) , lPD-Printing-Queue9 ( 11 ) , lPD-Printing-Queue10 ( 12 ) , IPPS-Printing ( 16 ) }
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"This object specifies the highest priority service advertised by Bonjour.
|
||
When this object is change, all services will be re-advertised with
|
||
the changed priority."
|
||
::= { npCfg 45 }
|
||
|
||
npCfgBonjourDomainName OBJECT-TYPE
|
||
SYNTAX OCTET STRING ( SIZE ( 0 .. 255 ) )
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The name used as the 'target name' in the DNS SRV records by
|
||
Multicast Domain Name System (Bonjour)."
|
||
::= { npCfg 46 }
|
||
|
||
npCfgDNSNameServerIdSecondary OBJECT-TYPE
|
||
SYNTAX IpAddress
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"IP address of Secondary DNS name-server."
|
||
::= { npCfg 47 }
|
||
|
||
npCfgIPv6ConfigState OBJECT-TYPE
|
||
SYNTAX INTEGER { ipv6-going-down ( 0 ) , ipv6-is-up ( 1 ) }
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"IPv6 stack status event; IPv6 enabled/disabled."
|
||
::= { npCfg 50 }
|
||
|
||
npCfgIPv6DNSAddr1 OBJECT-TYPE
|
||
SYNTAX InetAddress
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"IPv6 DNS Address, priority 1."
|
||
::= { npCfg 56 }
|
||
|
||
npCfgIPv6DNSAddr2 OBJECT-TYPE
|
||
SYNTAX InetAddress
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"IPv6 DNS Address, priority 2."
|
||
::= { npCfg 57 }
|
||
|
||
npCfgIPConfigPrecedence OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Allows to set uniform rules for parameter overwrite by
|
||
different configuration methods.
|
||
0 - Manual
|
||
1 - TFTP
|
||
2 - DHCPv4/Bootp
|
||
3 - DHCPv6 - only if ipv6 is supported
|
||
3/4 - Default - 4 if ipv6 is supported otherwise 3
|
||
The set string should be 0:1:2:3:4 (or 0:1:2:3 when ipv6 is not supported)
|
||
or any colon separated combination of the 5 (or 4) integral values. The
|
||
string should contain all integral values atleast and atmost once."
|
||
::= { npCfg 59 }
|
||
|
||
npCfgSTAWirelessMode OBJECT-TYPE
|
||
SYNTAX INTEGER { bg-Mode ( 0 ) , bgn-Mode ( 1 ) }
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Different standardized 802.11 wireless modes.
|
||
The following values are defined:
|
||
0 - b/g/n-mode (Default)
|
||
1 - n-mode only
|
||
Note: Guard Interval, AMSDU, Block Acknowledgement, and AMPDU are applicable in 802.11 n modes only.
|
||
"
|
||
::= { npCfg 72 }
|
||
|
||
npCfgWiFiDirectChannelNumber OBJECT-TYPE
|
||
SYNTAX INTEGER ( 1 .. 13 )
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The WiFi channel number used for Wireless/Wi-Fi Direct.
|
||
Region Allowed Channels
|
||
------------------- ----------------
|
||
US & Worldwide Safe 1 - 11
|
||
Rest of the world 1 - 13
|
||
If wireless station is enabled, this setting is ignored and the
|
||
channel used is determined by the AP to which the device is
|
||
associated to.
|
||
Default channel is 6.
|
||
"
|
||
::= { npCfg 85 }
|
||
|
||
npCfgWiFiDirectSSIDPrefix OBJECT-TYPE
|
||
SYNTAX OCTET STRING ( SIZE ( 1 .. 13 ) )
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
The prefix of the network name (SSID) used for Wireless/Wi-Fi
|
||
Direct. The value is 'HP-Print-XY-' where XY is the last two hex
|
||
characters from the wireless MAC address. On products supporting
|
||
Wi-Fi Direct, the value is 'DIRECT-XY-HP '. The prefix is read-only.
|
||
The value of this object is prefixed to the value of
|
||
npCfgWiFiDirectSSIDSuffix to form the complete SSID.
|
||
"
|
||
::= { npCfg 86 }
|
||
|
||
npCfgWiFiDirectSSIDSuffix OBJECT-TYPE
|
||
SYNTAX OCTET STRING ( SIZE ( 1 .. 19 ) )
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
The modifiable suffix of the network name (SSID) used for
|
||
Wireless/Wi-Fi Direct. The default is '<sub brand> <hp model>',
|
||
but it can be different depending on printer family.
|
||
The value of this object is concatenated to the value of
|
||
npCfgWiFiDirectSSIDPrefix to form the complete SSID.
|
||
"
|
||
::= { npCfg 87 }
|
||
|
||
npCfgWiFiDirectConnectionSecurity OBJECT-TYPE
|
||
SYNTAX INTEGER { Automatic ( 0 ) , Manual ( 1 ) , Advanced ( 2 ) }
|
||
MAX-ACCESS read-write
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"This is used to select the Wi-Fi Direct connection security method
|
||
which differentiates how the connection is done between a mobile
|
||
client and the printer. The following values are defined:
|
||
Automatic ( 0 )
|
||
Manual ( 1 )
|
||
Advanced ( 2 )
|
||
Automatic - Printer will accept all Wi-Fi Direct initiated
|
||
connections without requiring the user to push a button on the
|
||
printer. The user may have to enter a PIN, provided by the printer,
|
||
if the mobile device requests PIN method.
|
||
Manual - Wi-Fi Direct clients require printer interaction to
|
||
connect. The user has to push a button on the printer or enter a
|
||
PIN into the mobile device to connect depending on the method
|
||
requested by mobile device.
|
||
Advanced - This mode disables Wi-Fi Direct, switches to Wireless
|
||
Direct and allows configuration of advanced settings.
|
||
"
|
||
::= { npCfg 88 }
|
||
|
||
npCfgSysLogProtocol OBJECT-TYPE
|
||
SYNTAX INTEGER { tcp ( 6 ) , udp ( 17 ) }
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Protocol used by SysLog server for communication.
|
||
Default set to UDP"
|
||
::= { npCfg 97 }
|
||
|
||
npCfgSysLogPort OBJECT-TYPE
|
||
SYNTAX INTEGER ( 1 .. 65535 )
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Sys Log Server Port.
|
||
Default set to port number 514"
|
||
::= { npCfg 98 }
|
||
|
||
npCfgHpDAPAgentManualServerAddr OBJECT-TYPE
|
||
SYNTAX InetAddress
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Zero when Empty"
|
||
::= { npCfg 99 }
|
||
|
||
npTcpSyslogMax OBJECT-TYPE
|
||
SYNTAX Integer32 ( 0 .. 1000 )
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Maximum number of syslog packets to be sent
|
||
per minute. 0 = Disabled."
|
||
::= { npTcp 11 }
|
||
|
||
npTcpAppSyslogPriority OBJECT-TYPE
|
||
SYNTAX Integer32 ( 0 .. 8 )
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Priority below which the syslog messages will
|
||
not be sent.
|
||
Valid priority levels = 0 through 7.
|
||
Disabled = 8."
|
||
::= { npTcp 12 }
|
||
|
||
npCtlSLP OBJECT-TYPE
|
||
SYNTAX Integer32 ( 0 .. 1 )
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Configure Service Location Protocol (SLP) service.
|
||
(0) = SLP disabled
|
||
(1) = SLP enabled"
|
||
::= { npCtl 21 }
|
||
|
||
npCtlLPD OBJECT-TYPE
|
||
SYNTAX Integer32 ( 0 .. 1 )
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Configure Line Printer Daemon Protocol (LPD) service.
|
||
(0) = LPD disabled
|
||
(1) = LPD enabled"
|
||
::= { npCtl 22 }
|
||
|
||
npCtl9100 OBJECT-TYPE
|
||
SYNTAX Integer32 ( 0 .. 1 )
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Configure TCP port 9100 printing.
|
||
(0) = port 9100 printing disabled
|
||
(1) = port 9100 printing enabled"
|
||
::= { npCtl 24 }
|
||
|
||
npCtlSysLog OBJECT-TYPE
|
||
SYNTAX Integer32 ( 0 .. 1 )
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Configure Syslog service.
|
||
(0) = Syslog service disabled
|
||
(1) = Syslog service enabled
|
||
Enabled by default."
|
||
::= { npCtl 26 }
|
||
|
||
npCtlSnmpVersionAccess OBJECT-TYPE
|
||
SYNTAX INTEGER { snmpV1RW-snmpV3RW ( 1 ) , snmpV1RO-snmpV3RW ( 2 ) , snmpV1NoAccess-snmpV3RW ( 3 ) , snmpV1RW-snmpV3NoAccess ( 4 ) ,snmpV1RO-snmpV3NoAccess ( 5 ) }
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Manages an SNMP version's read and write access to the MIB."
|
||
::= { npCtl 27 }
|
||
|
||
npCtlSnmpV3InitAccount OBJECT-TYPE
|
||
SYNTAX INTEGER { Destroy ( 0 ) , blockInitEncrypt ( 4 ) }
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Used to create initial SNMPv3 account. The following rules apply:
|
||
0 = clear init account, only if previously 0.
|
||
4 = Block init account, only cold reset will clear or use Web User interface.
|
||
Setting this object to blocked (4) will block an initial account
|
||
creation until a cold reset."
|
||
::= { npCtl 28 }
|
||
|
||
npCtlBonjour OBJECT-TYPE
|
||
SYNTAX Integer32 ( 0 .. 1 )
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Configure Multicast Domain Name Service.
|
||
(0) = Bonjour disabled
|
||
(1) = Bonjour enabled"
|
||
::= { npCtl 29 }
|
||
|
||
npCtlNetworkConnectionMode OBJECT-TYPE
|
||
SYNTAX INTEGER { auto-cable-detect ( 1 ) , disable-radio ( 2 ) , disable-wired ( 3 ) }
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"This object controls the selection of the active network
|
||
interface used for communication. This is applicable to
|
||
products supporting dual wired and wireless network interfaces"
|
||
::= { npCtl 32 }
|
||
|
||
npCtlWSDiscovery OBJECT-TYPE
|
||
SYNTAX INTEGER { disable ( 0 ) , enable ( 1 ) }
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Web Services Discovery enable/disable."
|
||
::= { npCtl 36 }
|
||
|
||
npCtlWSPrint OBJECT-TYPE
|
||
SYNTAX INTEGER { disable ( 0 ) , enable ( 1 ) }
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Web Services Print enable/disable."
|
||
::= { npCtl 37 }
|
||
|
||
npCtlLLMNR OBJECT-TYPE
|
||
SYNTAX INTEGER { disable ( 0 ) , enable ( 1 ) }
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Link-Local Multicast Name Resolution( LLMNR ) enable/disable."
|
||
::= { npCtl 38 }
|
||
|
||
npCtlWPAD OBJECT-TYPE
|
||
SYNTAX INTEGER { disable ( 0 ) , automatic-Web-Proxy ( 1 ) , manual-url ( 2 ) , manual-proxy-settings ( 3 ) }
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
" Used to Disable and Enable Web-Proxy Auto Discovery."
|
||
::= { npCtl 39 }
|
||
|
||
npCtlFpDot11WirelessState OBJECT-TYPE
|
||
SYNTAX INTEGER { Disable ( 0 ) , Enable ( 1 )}
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Use for enabling and disabling Wireless Radio.
|
||
The following values are defined:
|
||
Disable = 0
|
||
Enable = 1
|
||
Default = 1(Enabled)"
|
||
::= { npCtl 47 }
|
||
|
||
npCtlDot11nSTAGuardInterval OBJECT-TYPE
|
||
SYNTAX INTEGER { Auto ( 0 ) , Short ( 1 ) , Long ( 2 ) }
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The guard interval is the space between symbols (characters) being transmitted.
|
||
The guard interval is there to eliminate intersymbol interference, which is referred to as ISI.
|
||
ISI happens when echoes or reflections from one symbol interfere with another. Adding time between
|
||
symbol transmissions allows these echoes and reflections to settle in before the next symbol is transmitted.
|
||
Short Guard Interval increases the data rate by roughly 10-11%.
|
||
The following values are defined:
|
||
0 - Auto (default)
|
||
1 - Short
|
||
2 - Long
|
||
"
|
||
::= { npCtl 51 }
|
||
|
||
npCtlDot11nSTAAMSDUAggregation OBJECT-TYPE
|
||
SYNTAX INTEGER { Disable ( 0 ) , Enable ( 1 ) }
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"802.11n can send multiple frames per single access to the medium by combining frames together into one larger frame.
|
||
There are two forms of frame aggregation:
|
||
Aggregated Mac Service Data Unit (A-MSDU) and Aggregated Mac Protocol Data Unit (A-MPDU).
|
||
A-MSDU increases the maximum frame transmission size from 2,304 bytes to almost 8k bytes (7935 to be exact)
|
||
while A-MPDU allows up to 64k bytes. A- MSDU creates the larger frame by combining smaller frames with
|
||
the same physical source and destination end points and traffic class (i.e. QoS) into one large frame with a common MAC header.
|
||
Disable = 0
|
||
Enable(Default) = 1
|
||
"
|
||
::= { npCtl 52 }
|
||
|
||
npCtlDot11nSTABlockACKs OBJECT-TYPE
|
||
SYNTAX INTEGER { Disable ( 0 ) , Enable ( 1 )}
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"This mechanism allows each of the aggregated data frames to be individually acknowledged or
|
||
retransmitted if affected by an error. Block acknowledgement compiles all the acknowledgements
|
||
of the individual constituent frames produced by MPDU aggregation into a single frame returned
|
||
by the recipient to the sender. This allows a compact and rapid mechanism to implement selective
|
||
retransmission of only those constituent frames that are not acknowledged.
|
||
Disable = 0
|
||
Enable(Default) = 1
|
||
"
|
||
::= { npCtl 53 }
|
||
|
||
npCtlDot11nSTAAMPDUAggregation OBJECT-TYPE
|
||
SYNTAX INTEGER { Disable ( 0 ) , Enable ( 1 ) }
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"802.11n can send multiple frames per single access to the medium by combining frames together into one larger frame.
|
||
There are two forms of frame aggregation:
|
||
Aggregated Mac Service Data Unit (A-MSDU) and Aggregated Mac Protocol Data Unit (A-MPDU).
|
||
A-MSDU increases the maximum frame transmission size from 2,304 bytes to almost 8k bytes (7935 to be exact)
|
||
while A-MPDU allows up to 64k bytes. A- MSDU creates the larger frame by combining smaller frames with
|
||
the same physical source and destination end points and traffic class (i.e. QoS) into one large frame with a common MAC header.
|
||
Disable = 0
|
||
Enable(Default) = 1
|
||
"
|
||
::= { npCtl 54 }
|
||
|
||
npCtlWiFiDirectSSIDBroadcast OBJECT-TYPE
|
||
SYNTAX INTEGER { not-allowed ( 0 ) , allowed ( 1 ) }
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"This is used to allow or hide broadcasting of the SSID (Network name).
|
||
Allowed(Default) = 1
|
||
Not Allowed = 0
|
||
Not Allowed (0) only takes effect when npCfgWiFiDirectConnectionSecurity is set to Advanced.
|
||
"
|
||
::= { npCtl 57 }
|
||
|
||
npCtlWiFiDirectHidePassphrase OBJECT-TYPE
|
||
SYNTAX INTEGER { show ( 0 ) , hide ( 1 ) }
|
||
MAX-ACCESS read-write
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"This controls display of the Wireless passphrase on configuration
|
||
reports/pages or on the control panel.
|
||
Show = 0
|
||
Hide = 1
|
||
This object also controls whether or not the passphrase is included in the NFC record.
|
||
Hide (1) only takes effect when npCfgWiFiDirectConnectionSecurity is set to Advanced
|
||
"
|
||
::= { npCtl 58 }
|
||
|
||
npCtlWiFiDirectHideSsid OBJECT-TYPE
|
||
SYNTAX INTEGER { show ( 0 ) , hide ( 1 ) }
|
||
MAX-ACCESS read-write
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"This controls display of the network name (SSID) on configuration
|
||
reports/pages or on the control panel.
|
||
Show = 0
|
||
Hide = 1
|
||
Hide (1) only takes effect when npCfgWifiDirectConnectionSecurity is set to Advanced
|
||
"
|
||
::= { npCtl 59 }
|
||
|
||
npCtlHpDAPAgentAnnounceState OBJECT-TYPE
|
||
SYNTAX INTEGER { Disable ( 0 ) , Enable ( 1 ) }
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Disable(Default) = 0
|
||
Enable = 1
|
||
"
|
||
::= { npCtl 65 }
|
||
|
||
npCtlHpDAPAgentRequireTrustedAuth OBJECT-TYPE
|
||
SYNTAX INTEGER { Disable ( 0 ) , Enable ( 1 ) }
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Disable(Default) = 0
|
||
Enable = 1
|
||
"
|
||
::= { npCtl 66 }
|
||
|
||
npCtlDeviceMode OBJECT-TYPE
|
||
SYNTAX INTEGER { WiredStationMode ( 1 ) , WirelessStationMode ( 2 ) , AccessPointMode (3) }
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
" Use to check the current state of the device.
|
||
WiredStationMode = 1
|
||
WirelessStationMode = 2
|
||
AccessPointMode = 3
|
||
"
|
||
::= { npCtl 67 }
|
||
|
||
npCtlAirPrintStatus OBJECT-TYPE
|
||
SYNTAX INTEGER { Disable ( 0 ) , Enable ( 1 ) }
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
" Use to Enabled/Disabled AirPrint functionality.
|
||
Disable = 0
|
||
Enable(Default) = 1
|
||
"
|
||
::= { npCtl 68 }
|
||
|
||
npCtlWirelessSTAState OBJECT-TYPE
|
||
SYNTAX INTEGER { disabled ( 0 ), enabled ( 1 ) }
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Configure 802.11 wireless station (STA) functionality
|
||
0 = Wireless station is disabled
|
||
1 = Wireless station is enabled
|
||
"
|
||
::= { npCtl 73 }
|
||
|
||
npCtlWiFiDirectState OBJECT-TYPE
|
||
SYNTAX INTEGER { disabled ( 0 ), enabled ( 1 ) }
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Configure 802.11 Wireless/Wi-Fi Direct functionality
|
||
0 = Wireless/Wi-Fi Direct is disabled
|
||
1 = Wireless/Wi-Fi Direct is enabled
|
||
"
|
||
::= { npCtl 74 }
|
||
|
||
npCtlAirScan OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
MAX-ACCESS read-write
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Used to Enable/Disable the AirScan and Secure AirScan service.
|
||
The value for this OID is a bit map with the following assignment
|
||
Bit 0 - AirScan
|
||
Bit 1 - Secure AirScan
|
||
This leads to the following values
|
||
Value Secure-AirScan AirScan
|
||
------------------------------------------
|
||
0 Disabled Disabled
|
||
1 Disabled Enabled
|
||
2 Enabled Disabled
|
||
3 Enabled Enabled
|
||
"
|
||
::= { npCtl 79 }
|
||
|
||
npCtlAirFax OBJECT-TYPE
|
||
SYNTAX INTEGER { disable (0) , enable (1) }
|
||
MAX-ACCESS read-write
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Used to Enable/Disable the AirFax service.
|
||
Disable = 0
|
||
Enable (Default) = 1"
|
||
::= { npCtl 80 }
|
||
|
||
npCtlGCPrint OBJECT-TYPE
|
||
SYNTAX INTEGER { disable (0) , enable (1), remove (2) }
|
||
MAX-ACCESS read-write
|
||
STATUS optional
|
||
DESCRIPTION "Used to Enable/Disable/Remove(Hide) the GC Print service.
|
||
Disable = 0
|
||
Enable (Default) = 1
|
||
Remove = 2
|
||
If disable is specified and the device is registered for Google
|
||
Cloud Services, then the device will be unregistered.
|
||
When remove is specified to an unregistered device, the
|
||
UI aspects of the feature are hidden from end user, so that the
|
||
user will not be able to see the Google cloud Print Service feature.
|
||
When remove is specified to a registered device, the device will
|
||
disable the feature and remove all user interfaces."
|
||
::= { npCtl 81 }
|
||
|
||
npCtlRebootMode OBJECT-TYPE
|
||
SYNTAX INTEGER { normal (0) , recovery (1)}
|
||
MAX-ACCESS read-write
|
||
STATUS optional
|
||
DESCRIPTION "Used to set a reboot mode on the device.
|
||
normal = 0 (default)
|
||
recovery = 1 (firmware with minimal features, once
|
||
in this mode, device will check a web
|
||
URL for firmware upgrades)
|
||
Setting this OID will force the device to reboot in
|
||
a specified mode. The reboot itself may take upwards
|
||
of 30 seconds (will differ for different devices)
|
||
Note: This was needed by WJA for the newer Sirius
|
||
on Linux class of devices."
|
||
::= { npCtl 83 }
|
||
|
||
npNpiPaeClass OBJECT-TYPE
|
||
SYNTAX INTEGER { printer ( 1 ) , plotter ( 2 ) , xStation ( 3 ) }
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The class assigned to the peripheral onto which
|
||
this card is plugged."
|
||
::= { npNpiPeripheralAttributeEntry 2 }
|
||
|
||
npNpiPaeIdentification OBJECT-TYPE
|
||
SYNTAX INTEGER { laserjet-IIISI ( 1 ) , laserjet-4SI ( 5 ) }
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The Identification number of the peripheral. These values are
|
||
defined in the MIO spec. DesignJet, PaintJet XL300, and
|
||
DesignJet/600 peripherals will identify themselves as
|
||
LaserJet-IIIsi."
|
||
::= { npNpiPeripheralAttributeEntry 3 }
|
||
|
||
npIpxSapInfo OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"This is a 50 byte array that contains the following
|
||
information.
|
||
2 bytes: bindery object type (always 030c in hi-lo order)
|
||
12 bytes: Mac address of card (ASCII)
|
||
2 bytes: frame type
|
||
also high bit (8000) is set if card is not configured
|
||
2 bytes : unit type (hex 81 for NetJet card)
|
||
32 bytes: node name (ASCII) which is:
|
||
print server name for Queue Server mode
|
||
printer name for RPTR mode"
|
||
::= { npIpx 6 }
|
||
|
||
npPortNumPorts OBJECT-TYPE
|
||
SYNTAX Integer32 ( 0 .. 255 )
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The number of peripheral interfaces supported by this device."
|
||
::= { npPort 1 }
|
||
|
||
npDhcpFQDNBehavior OBJECT-TYPE
|
||
SYNTAX INTEGER { Present-JD-Behavior ( 0 ) , RFC4702-compliant-Behavior ( 1 ) }
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"This object defines the FQDN behavior in Jetdirect. Set this to
|
||
( 0 ) - Present Jetdirect Behavior
|
||
( 1 ) - RFC 4702 compliant behavior"
|
||
::= { npDhcp 4 }
|
||
|
||
npWebProxyServerId OBJECT-TYPE
|
||
SYNTAX OCTET STRING ( SIZE ( 0 .. 255 ) )
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"IP address or hostname of web proxy server."
|
||
::= { npWeb 12 }
|
||
|
||
npWebProxyServerPort OBJECT-TYPE
|
||
SYNTAX Integer32
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"IP port of web proxy server"
|
||
::= { npWeb 13 }
|
||
|
||
npWebProxyUserName OBJECT-TYPE
|
||
SYNTAX OCTET STRING ( SIZE ( 0 .. 64 ) )
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Proxy web user identification"
|
||
::= { npWeb 14 }
|
||
|
||
npWebProxyUserPasswd OBJECT-TYPE
|
||
SYNTAX OCTET STRING ( SIZE ( 0 .. 32 ) )
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Proxy web user password"
|
||
::= { npWeb 15 }
|
||
|
||
npSecurityDot11ServerAuthentication OBJECT-TYPE
|
||
SYNTAX INTEGER { eap-md5 ( 1 ) , eap-tls ( 2 ) , leap ( 4 ) , peap ( 8 ) , ttls ( 16 ) }
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Server-Based Authentication with the following bitwise values:
|
||
None(0),
|
||
EAP-MD5(1),
|
||
EAP-TLS(2),
|
||
LEAP(4),
|
||
PEAP(8),
|
||
TTLS(16)"
|
||
::= { npSecurity 1 }
|
||
|
||
npSecurityDot1xEapMd5Identity OBJECT-TYPE
|
||
SYNTAX OCTET STRING ( SIZE ( 0 .. 130 ) )
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Radius MD5 authentication User Name."
|
||
::= { npSecurity 2 }
|
||
|
||
npSecurityDot1xTLSAuthServerId OBJECT-TYPE
|
||
SYNTAX OCTET STRING ( SIZE ( 0 .. 64 ) )
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"TLS authentication Server ID."
|
||
::= { npSecurity 3 }
|
||
|
||
npSecurityPublicKey OBJECT-TYPE
|
||
SYNTAX OCTET STRING ( SIZE ( 0 .. 64 ) )
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The public key of a public/private key pair to be
|
||
used by applications to set encrypted values."
|
||
::= { npSecurity 4 }
|
||
|
||
npSecurityDot11EncryptedDot1xEapMd5Secret OBJECT-TYPE
|
||
SYNTAX OCTET STRING ( SIZE ( 0 .. 130 ) )
|
||
MAX-ACCESS write-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The encrypted dot1xEapMD5Secret authentication password.
|
||
Use the npSecurityPublicKey to encrypt this value.
|
||
Setting this object will cause the card to reconfigure."
|
||
::= { npSecurity 6 }
|
||
|
||
npSecurityDot11EncryptedWEPKey OBJECT-TYPE
|
||
SYNTAX OCTET STRING ( SIZE ( 0 .. 13 ) )
|
||
MAX-ACCESS write-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The encrypted WEP Key value. Use
|
||
the npSecurityDot11PublicKey to encrypt this value.
|
||
Setting this object will cause the card to reconfigure."
|
||
::= { npSecurityDot11EncryptedWEPKeyEntry 2 }
|
||
|
||
npSecurityDot11SignalStrength OBJECT-TYPE
|
||
SYNTAX INTEGER { level-1-TBD ( 1 ) , level-2-TBD ( 2 ) , level-3-TBD ( 3 ) , level-4-TBD ( 4 ) , level-5-TBD ( 5 ) }
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"A weighted average over time of the signal strength
|
||
between the access point and the print server in infrastructure
|
||
mode. Not applicable when in ad hoc mode."
|
||
::= { npSecurity 8 }
|
||
|
||
npSecurityDot11SSID OBJECT-TYPE
|
||
SYNTAX OCTET STRING ( SIZE ( 0 .. 32 ) )
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"A discovered SSID value."
|
||
::= { npSecurityDot11SSIDEntry 2 }
|
||
|
||
npSecurityDot11SSIDTableNumEntries OBJECT-TYPE
|
||
SYNTAX Integer32
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Displays the number of discovered SSIDs in
|
||
the SSID Table."
|
||
::= { npSecurity 10 }
|
||
|
||
npSecuritySnmpV3EncryptedUserName OBJECT-TYPE
|
||
SYNTAX OCTET STRING ( SIZE ( 256 ) )
|
||
MAX-ACCESS write-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The encrypted SNMPv3 User Name.
|
||
Use the npSecurityPublicKey to encrypt this value.
|
||
The new SNMPv3 User Account will be installed after the
|
||
npSecuritySnmpV3EncryptedUserName, npSecuritySnmpV3AuthKeyPassPhrase
|
||
and npSecuritySnmpV3PrivKeyPassPharse have been set."
|
||
::= { npSecurity 13 }
|
||
|
||
npSecuritySnmpV3AuthKeyPassPhrase OBJECT-TYPE
|
||
SYNTAX OCTET STRING ( SIZE ( 256 ) )
|
||
MAX-ACCESS write-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The encrypted SNMPv3 Authentication passphrase or key .
|
||
Use the npSecurityPublicKey to encrypt this value.
|
||
The new SNMPv3 User Account will be installed after the
|
||
npSecuritySnmpV3EncryptedUserName, npSecuritySnmpV3AuthKeyPassPhrase
|
||
and npSecuritySnmpV3PrivKeyPassPharse have been set.
|
||
Set npSecuritySnmpV3AuthAlgorithm, npSecuritySnmpV3PrivAlgorithm and npSecuritySnmpV3PassPhrase
|
||
to the required values before setting this OID.
|
||
"
|
||
::= { npSecurity 14 }
|
||
|
||
npSecuritySnmpV3PrivKeyPassPhrase OBJECT-TYPE
|
||
SYNTAX OCTET STRING ( SIZE ( 256 ) )
|
||
MAX-ACCESS write-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The encrypted SNMPv3 Privacy passphrase or key.
|
||
Use the npSecurityPublicKey to encrypt this value.
|
||
When setting this object, all three user account objects (npSecuritySnmpV3EncryptedUserName,
|
||
npSecuritySnmpV3AuthKeyPassPhrase, and npSecuritySnmpV3PrivKeyPassPhrase) should also be set in
|
||
the same multi-varbind request.
|
||
Implementations may accept the objects in separate SNMP requests, or they may return a inconsistentValue (12)
|
||
failure to indicate that other objects are required.
|
||
If setting the objects individually is allowed, the User Account will not be installed until after all three
|
||
objects have been set.
|
||
The other OID's related to SNMPv3 encryption are
|
||
npSecuritySnmpV3PrivAlgorithm and npSecuritySnmpV3PassPhrase, please ensure that they are set appropriately.
|
||
This OID can only be SET if the inital SNMP V3 account is not created
|
||
(i.e. the value of npCtlSnmpV3InitAccount is 0)
|
||
The values of npSecuritySnmpV3PrivAlgorithm and npSecuritySnmpV3PassPhrase must be set appropriately
|
||
before setting the value of this OID.
|
||
"
|
||
::= { npSecurity 15 }
|
||
|
||
npSecurityDot11ExactMatchServerId OBJECT-TYPE
|
||
SYNTAX INTEGER { true ( 1 ) , false ( 2 ) }
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates if an exact match is required on the EAP Server ID."
|
||
::= { npSecurity 19 }
|
||
|
||
npSecurityDot11EncryptionStrength OBJECT-TYPE
|
||
SYNTAX INTEGER { low ( 1 ) , medium ( 2 ) , high ( 3 ) }
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates the EAP encrytpion strength."
|
||
::= { npSecurity 20 }
|
||
|
||
npSecuritySslRedirection OBJECT-TYPE
|
||
SYNTAX INTEGER { redirectionEnabled ( 1 ) , redirectionDisabled ( 2 ) }
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Setting this object causes the SSL redirection connection
|
||
to be enabled or disabled."
|
||
::= { npSecurity 23 }
|
||
|
||
npSecurityServicesSupported OBJECT-TYPE
|
||
SYNTAX Integer32
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"BITWISE indication of the 802.11 security services this device supports.
|
||
The following bits are defined:
|
||
MD5 (0)
|
||
TLS (1)
|
||
TTLS (2)
|
||
LEAP (3)
|
||
PEAP (4)
|
||
Reserved (5 - 15)
|
||
WEP (16)
|
||
WPA (17)
|
||
AES (18)
|
||
WPA2 (19)
|
||
AUTO_FOR_WEP_SUPPORTED (20)
|
||
AUTO_FOR_WPA_SUPPORTED (21)
|
||
AUTO_FOR_ENCRYPTION_SUPPORTED (22)
|
||
Reserved (23 - 31)"
|
||
::= { npSecurity 27 }
|
||
|
||
npSecurityDot11Encryption OBJECT-TYPE
|
||
SYNTAX Integer32
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"802.11 encryption method currently enabled.
|
||
The following values are defined:
|
||
NONE (0x00)
|
||
SSN/WEP (0x01)
|
||
TKIP (0x02)
|
||
AES (0x03)
|
||
AUTO (0x04)
|
||
Reserved (5 - 31)
|
||
It is advised not to use dot11PrivacyInvoked OID anymore, instead use npSecurityDot11Encryption.
|
||
Since Jetdirect updates the same variable when the set happens through any of the two OIDs and
|
||
npSecurityDot11Encryption is more versatile, it is recommended to use this OID.
|
||
"
|
||
::= { npSecurity 28 }
|
||
|
||
npSecurityDot11MulticastCipher OBJECT-TYPE
|
||
SYNTAX Integer32
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"BITWISE indication of the multicast cipher method currently enabled.
|
||
At minimum, one bit must be set.
|
||
The following bits are defined:
|
||
WEP (0)
|
||
WPA (1)
|
||
Reserved (2 - 31)"
|
||
::= { npSecurity 29 }
|
||
|
||
npSecurityDot11EncryptedWPAConfigPSKPassPhrase OBJECT-TYPE
|
||
SYNTAX OCTET STRING ( SIZE ( 0 | 8 .. 63 ) )
|
||
MAX-ACCESS write-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The encrypted WPA Config PSK PassPhrase. Use the
|
||
npSecurityPublicKey to encrypt this value"
|
||
::= { npSecurity 36 }
|
||
|
||
npSecuritySslEncryptionStrength OBJECT-TYPE
|
||
SYNTAX INTEGER { low ( 1 ) , medium ( 2 ) , high ( 3 ) }
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The SSL Encryption Strength.
|
||
Setting to Low, Medium or High decides the set of Cipher Suites that
|
||
would be supported by the device."
|
||
::= { npSecurity 40 }
|
||
|
||
npSecurityDot11DynamicEncryption OBJECT-TYPE
|
||
SYNTAX INTEGER { NONE ( 0 ) , BASIC ( 1 ) , WPA ( 2 ) , WPA2 ( 3 ) , AUTO ( 4 ) }
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"WPA mode.
|
||
(0x00) = NONE
|
||
(0x01) = BASIC
|
||
(0x02) = WPA
|
||
(0x03) = WPA2
|
||
(0x04) = AUTO"
|
||
::= { npSecurity 42 }
|
||
|
||
npSecurityDot11LinkAuthentication OBJECT-TYPE
|
||
SYNTAX INTEGER { open ( 1 ) , shared-key ( 2 ) , leap ( 128 ) , auto ( 143 ) }
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"DOT11 Link Authentication modes.
|
||
(1) = OPEN
|
||
(2) = SHARED-KEY
|
||
(128) = LEAP
|
||
(143) = AUTO
|
||
We can set the Link Authentication using the object dot11AuthenticationAlgorithmsEnable ( OID: 1.2.840.10036.1.2.1.3.x )
|
||
Since the dot11AuthenticationAlgorithsmEnable object does not supports setting of AUTO option, we provide this object.
|
||
Through this OID you can set to any one of the above options.
|
||
Whereas using the dot11AuthenticationAlgorithmsEnable object we can set either OPEN OR SHARED mode only."
|
||
::= { npSecurity 43 }
|
||
|
||
npSecuritySnmpV3AuthAlgorithm OBJECT-TYPE
|
||
SYNTAX INTEGER { md5 ( 2 ), sha-1 ( 3 ) }
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates the Authentication Algorithm used.
|
||
It can have the value MD5 or SHA-1.
|
||
This key will have a default value set to MD5.
|
||
The following values are defined:
|
||
MD5 2 (Default)
|
||
SHA-1 3
|
||
"
|
||
::= { npSecurity 44 }
|
||
|
||
npSecuritySnmpV3PrivAlgorithm OBJECT-TYPE
|
||
SYNTAX INTEGER { des ( 2 ), aes-128 ( 3 ) }
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates the Privacy Algorithm used.
|
||
It can have the value DES or AES-128.
|
||
This key will have a default value set to DES.
|
||
The following values are defined:
|
||
DES 2 (Default)
|
||
AES-128 3
|
||
"
|
||
::= { npSecurity 45 }
|
||
|
||
npSecuritySnmpV3PassPhrase OBJECT-TYPE
|
||
SYNTAX INTEGER { key ( 0 ), passphrase ( 1 ) }
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates whether npSecuritySnmpV3AuthKeyPassPhrase and npSecuritySnmpV3PrivKeyPassPharse OIDs
|
||
will have Passphrase or key value.
|
||
Key Value 0
|
||
Passphrase 1
|
||
"
|
||
::= { npSecurity 46 }
|
||
|
||
npSecurityWirelessDirectEncryptedPassPhrase OBJECT-TYPE
|
||
SYNTAX OCTET STRING ( SIZE ( 1 .. 64 ) )
|
||
MAX-ACCESS write-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
The WPA2 Passphrase or pre-shared key for secure Wireless Direct.
|
||
The values allowed are 8 to 63 printable ASCII characters for passphrase
|
||
or a 64 character hex value for pre-shared key.
|
||
Use npSecurityPublicKey to encrypt this value.
|
||
"
|
||
::= { npSecurity 55 }
|
||
|
||
npSecurityDot1xFailSafe OBJECT-TYPE
|
||
SYNTAX INTEGER { Enable ( 1 ) , Disable ( 0 ) }
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"After configuring 802.1x on the printer and switching it over to a secured network, if authentication is
|
||
successful printer retains connectivity and if it fails it loses connectivity.
|
||
In case of authentication failure, it does not acquire connectivity even when switched over to an unsecured network.
|
||
802.1x failsafe is a feature which allows printer to retain connectivity in a unsecured network even if authentication fails.
|
||
Setting this OID to 1 enables this feature and setting to 0 disables this feature.
|
||
Connect anyway (802.1x Fail-Safe) ( 1 )
|
||
Block network (secure failure) ( 0 )
|
||
"
|
||
::= { npSecurity 57 }
|
||
|
||
npSecuritySSLProtocol OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Different SSL Protocols can be selected with the following bitwise values:
|
||
SSL 3.0 (1)
|
||
TLS 1.0 (2)
|
||
TLS 1.1 (4)
|
||
TLS 1.2 (8)
|
||
"
|
||
::= { npSecurity 58 }
|
||
|
||
trapDestinationNum OBJECT-TYPE
|
||
SYNTAX Integer32
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The number of trap destinations."
|
||
::= { trapDest 1 }
|
||
|
||
trapTest OBJECT-TYPE
|
||
SYNTAX Integer32
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Causes agent to send an snmp trap to hosts registered in the trap
|
||
destination table. Value specified will be used as the specific
|
||
trap id."
|
||
::= { trapDest 3 }
|
||
|
||
trapSource OBJECT-TYPE
|
||
SYNTAX Integer32
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Sets the agent internal source for traps. Possibilities are as follows:
|
||
0 = ALL_TRAPS_ON
|
||
1 = ASYNC_PERIPHERAL_STATUS traps only
|
||
2 = proprietary PML traps only
|
||
3 = alert table traps only
|
||
This object was changed to read-only to accommodate the SNMPv3
|
||
Notifiaction tables requirement to recieve all traps. SNMPv3 tags
|
||
are used to filter SNMP Trap sources."
|
||
::= { trapDest 4 }
|
||
|
||
trapFilterDelay OBJECT-TYPE
|
||
SYNTAX Integer32
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The purpose of the trap filter feature is to prevent multiple traps
|
||
of the same specificTrapId to be sent within a short period of time.
|
||
This object assigns the period of time within which a duplicate trap
|
||
will be blocked. This value is in 1/10 second intervals and the default
|
||
value is set to 50 corresponding to 5 seconds. This value remains
|
||
persistent
|
||
through a powercycle."
|
||
::= { trapDest 5 }
|
||
|
||
trapFQDNNum OBJECT-TYPE
|
||
SYNTAX Integer32
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Number of trapFQDNTable rows."
|
||
::= { trapDest 6 }
|
||
|
||
setCommunityName OBJECT-TYPE
|
||
SYNTAX OCTET STRING ( SIZE ( 0 .. 255 ) )
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"This object controls access of snmp read-write requests. Factory
|
||
default configuration provides authentication of incoming packets
|
||
with community names: internal and public. This object overrides the
|
||
factory default settings so that the factory default setttings no longer
|
||
work. This object returns SET or NOT_SET."
|
||
::= { community 1 }
|
||
|
||
getCommunityName OBJECT-TYPE
|
||
SYNTAX OCTET STRING ( SIZE ( 0 .. 255 ) )
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"This object controls access of snmp read requests. Factory
|
||
default configuration provides authentication of incoming packets
|
||
with community names: internal and public. This object provides
|
||
access in addition to the factory default settings. If
|
||
set, then authentication will succeed with any of the following
|
||
community names: internal, public, getCommunityName, or
|
||
setCommunityName. This object returns SET or NOT_SET."
|
||
::= { community 2 }
|
||
|
||
ppmGeneralNaturalLanguage OBJECT-TYPE
|
||
SYNTAX SnmpAdminString (SIZE (0..63))
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The natural language tag (RFC 3066), specified in US-ASCII, for
|
||
all localized text string objects defined in this MIB (syntax of
|
||
'SnmpAdminString'), or the empty string if not specified. For
|
||
example, 'fr-CH' (French as written in Switzerland).
|
||
Compatibility Note: At the time of publication of this MIB,
|
||
language tags are restricted to US-ASCII. In order to support
|
||
possible future evolution of languages tags (in a successor to
|
||
RFC 3066) to allow non-ASCII characters, this object has been
|
||
defined with a syntax of UTF-8 (RFC 3629).
|
||
This natural language tag is necessary for support of correct
|
||
glyph selection for text display, for support of text-to-
|
||
speech, for support of correct sorting of text values, etc.
|
||
If this object is empty, then the natural language for all
|
||
localized text string objects in this MIB MUST default to
|
||
'en-US' (US English)."
|
||
REFERENCE
|
||
"prtGeneralCurrentLocalization in IETF Printer MIB (RFC
|
||
1759/3805).
|
||
jobNaturalLanguageTag in IETF Job Monitoring MIB (RFC 2707)."
|
||
DEFVAL { ''H } -- no natural language tag
|
||
::= { ppmGeneral 1 }
|
||
|
||
ppmGeneralNumberOfPrinters OBJECT-TYPE
|
||
SYNTAX Gauge32
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The number of printers supported on this network system,
|
||
i.e., the number of entries in the 'ppmPrinterTable' below, or
|
||
zero if no printers are currently configured."
|
||
DEFVAL { 0 } -- no printers configured
|
||
::= { ppmGeneral 2 }
|
||
|
||
ppmGeneralNumberOfPorts OBJECT-TYPE
|
||
SYNTAX Gauge32
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The number of printer ports supported on this network system,
|
||
i.e., the number of entries in the 'ppmPortTable' below, or
|
||
zero if no printer ports are currently configured."
|
||
DEFVAL { 0 } -- no printer ports configured
|
||
::= { ppmGeneral 3 }
|
||
|
||
ppmPrinterName OBJECT-TYPE
|
||
SYNTAX SnmpAdminString (SIZE (0..127))
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"A user friendly name for this printer that may be used to
|
||
facilitate user selection of a printer supported by a network
|
||
system, in the locale specified by 'ppmGeneralNaturalLanguage'.
|
||
This printer name may contain non-ASCII characters that are NOT
|
||
allowed in a URI (RFC 3986) without percent-encoding.
|
||
Systems that implement the IETF Printer MIB v1 (RFC 1759) SHOULD
|
||
implement this object as an augmentation to the Printer MIB v1.
|
||
Systems that implement the IETF Printer MIB v2 (RFC 3805) MUST
|
||
ensure that the value of this object is identical to the value
|
||
of 'prtGeneralPrinterName' for each printer.
|
||
The value of this object SHOULD be unique across all printers on
|
||
this network system and SHOULD be meaningful to end users
|
||
(e.g., 'PrinterXYZ').
|
||
The value of this object SHOULD be set by an out-of-band method
|
||
(e.g., local console) during installation (by the vendor or site
|
||
administrator) and SHOULD NOT be subsequently modified, so that
|
||
the value can be used as a static key for access to the printer.
|
||
The charset of this text string object is UTF-8 (RFC 3629), in
|
||
order to support names that cannot be represented in US-ASCII."
|
||
REFERENCE
|
||
"prtGeneralPrinterName in IETF Printer MIB v2 (RFC 3805).
|
||
printer-name in IPP/1.1 (RFC 2911)."
|
||
DEFVAL { ''H } -- printer name not specified
|
||
::= { ppmPrinterEntry 2 }
|
||
|
||
ppmPrinterIEEE1284DeviceId OBJECT-TYPE
|
||
SYNTAX OCTET STRING (SIZE (0..1023))
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The IEEE 1284 device ID for this printer, a set of capabilities
|
||
(keys and values) specified in the US-ASCII charset and the
|
||
format 'key1: value {, value }; ... keyN: value {,value };',
|
||
as follows:
|
||
(a) SPACE (0x20), TAB (0x09), VTAB (0x0B), CR (0x0D), NL (0x0A),
|
||
and FF (0x0C) are allowed, but are ignored when parsing
|
||
(b) other control characters (less than 0x20) MUST NOT be used
|
||
(c) COLON (0x3A), COMMA (0x2C), and SEMICOLON (0x3B) are used as
|
||
delimiters and MUST NOT be included in any key or value
|
||
(d) each key MUST be separated from value(s) using COLON (0x3A)
|
||
(e) multiple values MUST BE separated using COMMA (0x2C)
|
||
(f) each capability MUST BE terminated using SEMICOLON (0x3B)
|
||
(g) all printers MUST include the following capabilities
|
||
- MANUFACTURER (or abbreviation MFG)
|
||
- MODEL (or abbreviation MDL)
|
||
(h) all printers MAY include the following capabilities
|
||
- COMMAND SET (or abbreviation CMD)
|
||
- COMMENT
|
||
- ACTIVE COMMAND SET
|
||
For example (actually all on one line of text):
|
||
MANUFACTURER:ACME Manufacturing;
|
||
COMMAND SET:PCL,PJL,PS,XHTML-Print+xml;
|
||
MODEL:LaserBeam 9;
|
||
COMMENT:Anything you like;
|
||
ACTIVE COMMAND SET:PCL;
|
||
The value of this object MUST exactly match the IEEE 1284-2000
|
||
Device ID string, except that the length field MUST NOT be
|
||
specified. The value MUST be assigned by the Printer vendor
|
||
and MUST NOT be localized by the Print Service.
|
||
Compatibility Note: At the time of publication of this MIB,
|
||
IEEE device IDs are restricted to US-ASCII. In order to support
|
||
possible future evolution of IEEE device IDs (in a successor to
|
||
IEEE 1284-2000) to allow non-ASCII characters, this object has
|
||
been defined with a syntax of OCTET STRING to support the future
|
||
use of UTF-8 (RFC 3629).
|
||
If this object is empty, then the value of 'ppmPortProtocolType'
|
||
for the selected port SHOULD be used to load a generic driver."
|
||
REFERENCE
|
||
"Section 7.6 of IEEE 1284-2000.
|
||
printer-make-and-model in IPP/1.1 (RFC 2911)."
|
||
DEFVAL { ''H } -- no IEEE 1284 device ID
|
||
::= { ppmPrinterEntry 3 }
|
||
|
||
ppmPrinterNumberOfPorts OBJECT-TYPE
|
||
SYNTAX Gauge32
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The number of printer ports supported on this network printer,
|
||
i.e., the number of entries in the 'ppmPortTable' below with a
|
||
first index of 'ppmPrinterIndex', or zero if no printer ports
|
||
are currently configured."
|
||
DEFVAL { 0 } -- no printer ports configured
|
||
::= { ppmPrinterEntry 4 }
|
||
|
||
ppmPrinterPreferredPortIndex OBJECT-TYPE
|
||
SYNTAX Integer32 (0..2147483647)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The value of 'ppmPortIndex' for the preferred port for this
|
||
printer (configured by vendor or site administrator), or zero if
|
||
not specified.
|
||
Compatibility Note: The value of zero is NOT valid for
|
||
'ppmPortIndex'. It is an out-of-band value.
|
||
If this object is non-zero, then installation applications
|
||
SHOULD default to this port in their user interface dialogue."
|
||
REFERENCE
|
||
"document-format-default in IPP/1.1 (RFC 2911)."
|
||
DEFVAL { 0 } -- no preferred port configured
|
||
::= { ppmPrinterEntry 5 }
|
||
|
||
ppmPrinterHrDeviceIndex OBJECT-TYPE
|
||
SYNTAX Integer32 (0..2147483647)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The value of 'hrDeviceIndex' in the IETF Host Resources MIB
|
||
(RFC 1514/2790), or zero if not specified. This value of
|
||
'hrDeviceIndex' MAY be used for status queries for this printer
|
||
if the value of 'ppmPrinterSnmpQueryEnabled' is 'true'.
|
||
Compatibility Note: The value of zero is NOT valid for
|
||
'hrDeviceIndex'. It is an out-of-band value.
|
||
If this object is zero, then monitoring applications MUST NOT
|
||
attempt status queries for this printer in the IETF Host
|
||
Resources MIB (RFC 1514/2790) and/or IETF Printer MIB
|
||
(RFC 1759/3805)."
|
||
REFERENCE
|
||
"hrDeviceStatus, hrPrinterStatus, hrPrinterDetectedErrorState
|
||
in IETF Host Resources MIB (RFC 1514/2790).
|
||
Section 2.2.13.2 'Overall Printer Status' and
|
||
Appendix E 'Overall Printer Status Table' in IETF Printer MIB v2
|
||
(RFC 3805)."
|
||
DEFVAL { 0 } -- no host device index
|
||
::= { ppmPrinterEntry 6 }
|
||
|
||
ppmPrinterSnmpCommunityName OBJECT-TYPE
|
||
SYNTAX OCTET STRING (SIZE (0..255))
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The SNMP read community name, an opaque binary string, for
|
||
access to status information in IETF Host Resources MIB (RFC
|
||
1514/2790) and IETF Printer MIB (RFC 1759/3805) for this printer
|
||
via the value of 'ppmPrinterHrDeviceIndex' (i.e., a 'MIB view'
|
||
of these two MIBs).
|
||
Security Warning: Due to the widespread availability of free
|
||
'packet sniffers' (network traffic snooping applications) and
|
||
SNMP packet decoders, SNMP community names no longer offer even
|
||
weak security. This object SHOULD only be used to support 'MIB
|
||
views'. Implementations SHOULD use SNMPv3 security to protect
|
||
network resources from unauthorized monitoring.
|
||
If this object is empty, then the SNMP read community name for
|
||
this printer (if any) SHOULD default to 'public' in US-ASCII."
|
||
REFERENCE
|
||
"snmpCommunityName in IETF SNMP Community MIB (RFC 3584)."
|
||
DEFVAL { ''H } -- no SNMP read community name
|
||
::= { ppmPrinterEntry 7 }
|
||
|
||
ppmPrinterSnmpQueryEnabled OBJECT-TYPE
|
||
SYNTAX TruthValue
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The status query mode for this printer, for queries by
|
||
monitoring applications in the IETF Host Resources MIB
|
||
(RFC 1514/2790) and/or IETF Printer MIB (RFC 1759/3805).
|
||
If this object is 'true', then monitoring applications MAY
|
||
attempt status queries for this printer in the IETF Host
|
||
Resources MIB and/or IETF Printer MIB.
|
||
If this object is 'false', then monitoring applications MUST
|
||
NOT attempt status queries for this printer in the IETF Host
|
||
Resources MIB and/or IETF Printer MIB."
|
||
REFERENCE
|
||
"ppmPrinterSnmpCommunityName."
|
||
DEFVAL { false } -- SNMP status queries disabled
|
||
::= { ppmPrinterEntry 8 }
|
||
|
||
ppmPortEnabled OBJECT-TYPE
|
||
SYNTAX TruthValue
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The current administrative configuration mode for this port.
|
||
If this object is 'false', then applications MUST NOT attempt
|
||
installation of this port and SHOULD NOT attempt print job
|
||
submission to this port.
|
||
If this object is 'true', then the port is currently enabled.
|
||
If this object is 'false', then the port is currently disabled."
|
||
REFERENCE
|
||
"ppmPortProtocolType and ppmPortHrDeviceIndex."
|
||
DEFVAL { false } -- port disabled
|
||
::= { ppmPortEntry 2 }
|
||
|
||
ppmPortName OBJECT-TYPE
|
||
SYNTAX SnmpAdminString (SIZE (0..127))
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"A user friendly name for this port that may be used to
|
||
facilitate user selection of a port on a multi-port network
|
||
system, in the locale specified by 'ppmGeneralNaturalLanguage'.
|
||
This port name may contain non-ASCII characters that are NOT
|
||
allowed in a URI (RFC 3986) without percent-encoding.
|
||
The value of this object SHOULD be unique across all ports on
|
||
this network system and SHOULD be meaningful to end users
|
||
(e.g., 'PrinterXYZ-LPR-Duplex').
|
||
The value of this object SHOULD be set by an out-of-band method
|
||
(e.g., local console) during installation (by the vendor or site
|
||
administrator) and SHOULD NOT be subsequently modified, so that
|
||
the value can be used as a static key for access to the port.
|
||
The charset of this text string object is UTF-8 (RFC 3629), in
|
||
order to support names that cannot be represented in US-ASCII."
|
||
REFERENCE
|
||
"prtChannelInformation in IETF Printer MIB v2 (RFC 3805)."
|
||
DEFVAL { ''H } -- port name not specified
|
||
::= { ppmPortEntry 3 }
|
||
|
||
ppmPortServiceNameOrURI OBJECT-TYPE
|
||
SYNTAX SnmpAdminString (SIZE (0..255))
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The service name or URI for this port, specified in UTF-8 (RFC
|
||
3629), in the locale specified by 'ppmGeneralNaturalLanguage'.
|
||
The service name is typically a queue name.
|
||
Compatibility Note: At the time of publication of this MIB,
|
||
the Microsoft tools do not support LPR queue names longer than
|
||
32 characters. Network administrators SHOULD NOT assign longer
|
||
LPR queue names, to prevent interworking problems.
|
||
Compatibility Note: At the time of publication of this MIB,
|
||
IETF URI Generic Syntax (RFC 3986) requires that all non-ASCII
|
||
characters be percent-encoded, while IETF Internationalized
|
||
Resource Identifiers (RFC 3987) permits native UTF-8 resource
|
||
identifiers and supplies mappings to and from standard URI.
|
||
In order to support current use of IRI and possible future
|
||
evolution of URI (in a successor to RFC 3986) to allow non-ASCII
|
||
characters, this object has been defined with a syntax of UTF-8
|
||
(RFC 3629).
|
||
Examples of well-formed service URI for print protocols
|
||
include:
|
||
- 'lpr://foo.example.com/public-printer' (where 'public-
|
||
printer' is the LPR queue name portion)
|
||
and
|
||
- 'ipp://bar.example.com/printer/fox'
|
||
If this object is non-empty, then it SHOULD NOT conflict with a
|
||
the default (e.g., IANA-registered) or explicit transport target
|
||
port specified in 'ppmPortProtocolTargetPort'. In case of
|
||
conflict, the URI value in 'ppmPortServiceNameOrURI' is
|
||
authoritative (e.g., 'ipp://example.com:631/~smith/printer').
|
||
If this object is empty and 'ppmPortProtocolType' is
|
||
'chLPDServer(8)', the LPR queue name MUST default to 'LPR'."
|
||
REFERENCE
|
||
"IETF Line Printer Daemon Protocol (RFC 1179).
|
||
'lpr:' URL scheme in IANA-registered SLP Printer Schema at
|
||
http://www.iana.org/assignments/svrloc-templates/
|
||
printer-uri in LDAP Printer Schema (RFC 3712).
|
||
IPP/1.1: IPP URL Scheme (RFC 3510).
|
||
printer-uri-supported in IPP/1.1 (RFC 2911)."
|
||
DEFVAL { ''H } -- no service name or URI
|
||
::= { ppmPortEntry 4 }
|
||
|
||
ppmPortProtocolType OBJECT-TYPE
|
||
SYNTAX Integer32 (0..2147483647)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The protocol type of this printer port, specified as a value
|
||
from 'PrtChannelTypeTC' in the IANA Printer MIB (e.g.,
|
||
'chLPDServer(8)' for LPR (RFC 1179) or 'chPort9100(11)' for
|
||
Raw), or zero if not specified.
|
||
Compatibility Note: The value of zero is NOT registered in the
|
||
IANA Printer MIB. It is an out-of-band value. Thus the syntax
|
||
of this object is NOT specified as 'PrtChannelTypeTC'.
|
||
Systems that do NOT implement IETF Printer MIB v2 (RFC 3805)
|
||
SHOULD use 'chPort9100(11)' for Raw printing (with an alternate
|
||
port in 'ppmPortProtocolTargetPort', if necessary), because
|
||
'chPortTCP(37)' and 'chBidirPortTCP(38)' are NOT defined in
|
||
IETF Printer MIB v1 (RFC 1759).
|
||
Systems that do implement the IETF Printer MIB v2 (RFC 3805)
|
||
MAY instead use 'chPortTCP(37)' or 'chBidirPortTCP(38)' for Raw
|
||
printing, because 'chPort9100(11)' is DEPRECATED in IETF
|
||
Printer MIB v2.
|
||
Systems that implement any version of the IETF Printer MIB
|
||
(RFC 1759/3805) SHOULD use the same value of protocol type for
|
||
this port in the 'prtChannelTable', so monitoring applications
|
||
MAY search for more channel information and status."
|
||
REFERENCE
|
||
"PrtChannelTypeTC in IANA Printer MIB (RFC 3805 and
|
||
http://www.iana.org/assignments/ianaprinter-mib).
|
||
prtChannelType in IETF Printer MIB (RFC 1759/3805)."
|
||
DEFVAL { 0 } -- protocol type not specified
|
||
::= { ppmPortEntry 5 }
|
||
|
||
ppmPortProtocolTargetPort OBJECT-TYPE
|
||
SYNTAX Integer32 (0..65535)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The transport (TCP, UDP, etc.) target port number for this
|
||
protocol, i.e., an alternate port from the protocol default, or
|
||
zero if not specified (use protocol default). This object MAY
|
||
be used for any print protocol (from the Internet, NetWare,
|
||
AppleTalk, or other protocol suite).
|
||
If this object is zero, then the actual target port number is
|
||
the default port for the specified 'ppmPortProtocolType' (e.g.,
|
||
'chPort9100(11)' uses '9100').
|
||
If this object is non-zero, then it SHOULD NOT conflict with the
|
||
default (e.g., IANA-registered) target port implied by the value
|
||
of 'ppmPortProtocolType' or the explicit transport target port
|
||
specified in 'ppmPortServiceNameOrURI'. In case of conflict,
|
||
the URI value in 'ppmPortServiceNameOrURI' is authoritative
|
||
(e.g., 'ipp://example.com:631/~smith/printer').
|
||
If 'ppmPortProtocolType' is 'chLPDServer(8)', then this object
|
||
MUST be ignored (because LPR target port is fixed at '515')."
|
||
REFERENCE
|
||
"IETF Line Printer Daemon Protocol (RFC 1179)."
|
||
DEFVAL { 0 } -- target port not specified
|
||
::= { ppmPortEntry 6 }
|
||
|
||
ppmPortProtocolAltSourceEnabled OBJECT-TYPE
|
||
SYNTAX TruthValue
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The alternate transport source port mode for this protocol.
|
||
If this object is 'true', then transport source ports outside
|
||
the standard range MAY be used (e.g., LPR source port standard
|
||
range is defined in RFC 1179 to be '721' to '731', inclusive).
|
||
If this object is 'false', then transport source ports outside
|
||
the standard range MUST NOT be used (to avoid protocol
|
||
errors)."
|
||
REFERENCE
|
||
"IETF Line Printer Daemon Protocol (RFC 1179)."
|
||
DEFVAL { false } -- alt source ports disabled
|
||
::= { ppmPortEntry 7 }
|
||
|
||
ppmPortPrtChannelIndex OBJECT-TYPE
|
||
SYNTAX Integer32 (0..65535)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The value of 'prtChannelIndex' in IETF Printer MIB
|
||
(RFC 1759/3805) that corresponds to this printer port, or zero
|
||
if not specified.
|
||
Compatibility Note: The value of zero is NOT valid for
|
||
'prtChannelIndex'. It is an out-of-band value.
|
||
Systems that implement any version of the IETF Printer MIB
|
||
(RFC 1759/3805) SHOULD correctly implement this object, so
|
||
monitoring applications MAY search for print channel information
|
||
and status.
|
||
If this object is zero, then monitoring applications MUST NOT
|
||
attempt print channel status queries for this printer port."
|
||
REFERENCE
|
||
"prtChannelIndex, prtChannelIfIndex, prtChannelState, and
|
||
prtChannelStatus in IETF Printer MIB (RFC 1759/3805)."
|
||
DEFVAL { 0 } -- no print channel index
|
||
::= { ppmPortEntry 8 }
|
||
|
||
ppmPortLprByteCountEnabled OBJECT-TYPE
|
||
SYNTAX TruthValue
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The current LPR byte counting mode for this port if applicable.
|
||
If the value of 'ppmPortProtocolType' is NOT 'chLPDServer(8)',
|
||
then monitoring applications MUST ignore the value of this
|
||
object.
|
||
If this object is 'true', then LPR byte counting is enabled.
|
||
If this object is 'false', then LPR byte counting is disabled."
|
||
REFERENCE
|
||
"IETF Line Printer Daemon Protocol (RFC 1179)."
|
||
DEFVAL { false } -- LPR byte counting disabled
|
||
::= { ppmPortEntry 9 }
|
||
|
||
snmpEngineID OBJECT-TYPE
|
||
SYNTAX SnmpEngineID
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "An SNMP engine's administratively-unique identifier.
|
||
This information SHOULD be stored in non-volatile
|
||
storage so that it remains constant across
|
||
re-initializations of the SNMP engine.
|
||
"
|
||
::= { snmpEngine 1 }
|
||
|
||
snmpEngineBoots OBJECT-TYPE
|
||
SYNTAX INTEGER (1..2147483647)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "The number of times that the SNMP engine has
|
||
(re-)initialized itself since snmpEngineID
|
||
was last configured.
|
||
"
|
||
::= { snmpEngine 2 }
|
||
|
||
snmpEngineTime OBJECT-TYPE
|
||
SYNTAX INTEGER (0..2147483647)
|
||
UNITS "seconds"
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "The number of seconds since the value of
|
||
the snmpEngineBoots object last changed.
|
||
When incrementing this object's value would
|
||
cause it to exceed its maximum,
|
||
snmpEngineBoots is incremented as if a
|
||
re-initialization had occurred, and this
|
||
object's value consequently reverts to zero.
|
||
"
|
||
::= { snmpEngine 3 }
|
||
|
||
snmpEngineMaxMessageSize OBJECT-TYPE
|
||
SYNTAX INTEGER (484..2147483647)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "The maximum length in octets of an SNMP message
|
||
which this SNMP engine can send or receive and
|
||
process, determined as the minimum of the maximum
|
||
message size values supported among all of the
|
||
transports available to and supported by the engine.
|
||
"
|
||
::= { snmpEngine 4 }
|
||
|
||
snmpUnknownSecurityModels OBJECT-TYPE
|
||
SYNTAX Counter32
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "The total number of packets received by the SNMP
|
||
engine which were dropped because they referenced a
|
||
securityModel that was not known to or supported by
|
||
the SNMP engine.
|
||
"
|
||
::= { snmpMPDStats 1 }
|
||
|
||
snmpInvalidMsgs OBJECT-TYPE
|
||
SYNTAX Counter32
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "The total number of packets received by the SNMP
|
||
engine which were dropped because there were invalid
|
||
or inconsistent components in the SNMP message.
|
||
"
|
||
::= { snmpMPDStats 2 }
|
||
|
||
snmpUnknownPDUHandlers OBJECT-TYPE
|
||
SYNTAX Counter32
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "The total number of packets received by the SNMP
|
||
engine which were dropped because the PDU contained
|
||
in the packet could not be passed to an application
|
||
responsible for handling the pduType, e.g. no SNMP
|
||
application had registered for the proper
|
||
combination of the contextEngineID and the pduType.
|
||
"
|
||
::= { snmpMPDStats 3 }
|
||
|
||
usmStatsUnsupportedSecLevels OBJECT-TYPE
|
||
SYNTAX Counter32
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "The total number of packets received by the SNMP
|
||
engine which were dropped because they requested a
|
||
securityLevel that was unknown to the SNMP engine
|
||
or otherwise unavailable.
|
||
"
|
||
::= { usmStats 1 }
|
||
|
||
usmStatsNotInTimeWindows OBJECT-TYPE
|
||
SYNTAX Counter32
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "The total number of packets received by the SNMP
|
||
engine which were dropped because they appeared
|
||
outside of the authoritative SNMP engine's window.
|
||
"
|
||
::= { usmStats 2 }
|
||
|
||
usmStatsUnknownUserNames OBJECT-TYPE
|
||
SYNTAX Counter32
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "The total number of packets received by the SNMP
|
||
engine which were dropped because they referenced a
|
||
user that was not known to the SNMP engine.
|
||
"
|
||
::= { usmStats 3 }
|
||
|
||
usmStatsUnknownEngineIDs OBJECT-TYPE
|
||
SYNTAX Counter32
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "The total number of packets received by the SNMP
|
||
engine which were dropped because they referenced an
|
||
snmpEngineID that was not known to the SNMP engine.
|
||
"
|
||
::= { usmStats 4 }
|
||
|
||
usmStatsWrongDigests OBJECT-TYPE
|
||
SYNTAX Counter32
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "The total number of packets received by the SNMP
|
||
engine which were dropped because they didn't
|
||
contain the expected digest value.
|
||
"
|
||
::= { usmStats 5 }
|
||
|
||
usmStatsDecryptionErrors OBJECT-TYPE
|
||
SYNTAX Counter32
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "The total number of packets received by the SNMP
|
||
engine which were dropped because they could not be
|
||
decrypted.
|
||
"
|
||
::= { usmStats 6 }
|
||
|
||
usmUserSpinLock OBJECT-TYPE
|
||
SYNTAX TestAndIncr
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION "An advisory lock used to allow several cooperating
|
||
Command Generator Applications to coordinate their
|
||
use of facilities to alter secrets in the
|
||
usmUserTable.
|
||
"
|
||
::= { usmUser 1 }
|
||
|
||
usmUserSecurityName OBJECT-TYPE
|
||
SYNTAX SnmpAdminString
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "A human readable string representing the user in
|
||
Security Model independent format.
|
||
The default transformation of the User-based Security
|
||
Model dependent security ID to the securityName and
|
||
vice versa is the identity function so that the
|
||
securityName is the same as the userName.
|
||
"
|
||
::= { usmUserEntry 3 }
|
||
|
||
usmUserCloneFrom OBJECT-TYPE
|
||
SYNTAX RowPointer
|
||
MAX-ACCESS read-create
|
||
STATUS current
|
||
DESCRIPTION "A pointer to another conceptual row in this
|
||
usmUserTable. The user in this other conceptual
|
||
row is called the clone-from user.
|
||
When a new user is created (i.e., a new conceptual
|
||
row is instantiated in this table), the privacy and
|
||
authentication parameters of the new user must be
|
||
cloned from its clone-from user. These parameters are:
|
||
- authentication protocol (usmUserAuthProtocol)
|
||
- privacy protocol (usmUserPrivProtocol)
|
||
They will be copied regardless of what the current
|
||
value is.
|
||
Cloning also causes the initial values of the secret
|
||
authentication key (authKey) and the secret encryption
|
||
key (privKey) of the new user to be set to the same
|
||
values as the corresponding secrets of the clone-from
|
||
user to allow the KeyChange process to occur as
|
||
required during user creation.
|
||
The first time an instance of this object is set by
|
||
a management operation (either at or after its
|
||
instantiation), the cloning process is invoked.
|
||
Subsequent writes are successful but invoke no
|
||
action to be taken by the receiver.
|
||
The cloning process fails with an 'inconsistentName'
|
||
error if the conceptual row representing the
|
||
clone-from user does not exist or is not in an active
|
||
state when the cloning process is invoked.
|
||
When this object is read, the ZeroDotZero OID
|
||
is returned.
|
||
"
|
||
::= { usmUserEntry 4 }
|
||
|
||
usmUserAuthProtocol OBJECT-TYPE
|
||
SYNTAX AutonomousType
|
||
MAX-ACCESS read-create
|
||
STATUS current
|
||
DESCRIPTION "An indication of whether messages sent on behalf of
|
||
this user to/from the SNMP engine identified by
|
||
usmUserEngineID, can be authenticated, and if so,
|
||
the type of authentication protocol which is used.
|
||
An instance of this object is created concurrently
|
||
with the creation of any other object instance for
|
||
the same user (i.e., as part of the processing of
|
||
the set operation which creates the first object
|
||
instance in the same conceptual row).
|
||
If an initial set operation (i.e. at row creation time)
|
||
tries to set a value for an unknown or unsupported
|
||
protocol, then a 'wrongValue' error must be returned.
|
||
The value will be overwritten/set when a set operation
|
||
is performed on the corresponding instance of
|
||
usmUserCloneFrom.
|
||
Once instantiated, the value of such an instance of
|
||
this object can only be changed via a set operation to
|
||
the value of the usmNoAuthProtocol.
|
||
If a set operation tries to change the value of an
|
||
existing instance of this object to any value other
|
||
than usmNoAuthProtocol, then an 'inconsistentValue'
|
||
error must be returned.
|
||
If a set operation tries to set the value to the
|
||
usmNoAuthProtocol while the usmUserPrivProtocol value
|
||
in the same row is not equal to usmNoPrivProtocol,
|
||
then an 'inconsistentValue' error must be returned.
|
||
That means that an SNMP command generator application
|
||
must first ensure that the usmUserPrivProtocol is set
|
||
to the usmNoPrivProtocol value before it can set
|
||
the usmUserAuthProtocol value to usmNoAuthProtocol.
|
||
"
|
||
DEFVAL { usmNoAuthProtocol }
|
||
::= { usmUserEntry 5 }
|
||
|
||
usmUserAuthKeyChange OBJECT-TYPE
|
||
SYNTAX KeyChange -- typically (SIZE (0 | 32)) for HMACMD5
|
||
-- typically (SIZE (0 | 40)) for HMACSHA
|
||
MAX-ACCESS read-create
|
||
STATUS current
|
||
DESCRIPTION "An object, which when modified, causes the secret
|
||
authentication key used for messages sent on behalf
|
||
of this user to/from the SNMP engine identified by
|
||
usmUserEngineID, to be modified via a one-way
|
||
function.
|
||
The associated protocol is the usmUserAuthProtocol.
|
||
The associated secret key is the user's secret
|
||
authentication key (authKey). The associated hash
|
||
algorithm is the algorithm used by the user's
|
||
usmUserAuthProtocol.
|
||
When creating a new user, it is an 'inconsistentName'
|
||
error for a set operation to refer to this object
|
||
unless it is previously or concurrently initialized
|
||
through a set operation on the corresponding instance
|
||
of usmUserCloneFrom.
|
||
When the value of the corresponding usmUserAuthProtocol
|
||
is usmNoAuthProtocol, then a set is successful, but
|
||
effectively is a no-op.
|
||
When this object is read, the zero-length (empty)
|
||
string is returned.
|
||
The recommended way to do a key change is as follows:
|
||
1) GET(usmUserSpinLock.0) and save in sValue.
|
||
2) generate the keyChange value based on the old
|
||
(existing) secret key and the new secret key,
|
||
let us call this kcValue.
|
||
If you do the key change on behalf of another user:
|
||
3) SET(usmUserSpinLock.0=sValue,
|
||
usmUserAuthKeyChange=kcValue
|
||
usmUserPublic=randomValue)
|
||
If you do the key change for yourself:
|
||
4) SET(usmUserSpinLock.0=sValue,
|
||
usmUserOwnAuthKeyChange=kcValue
|
||
usmUserPublic=randomValue)
|
||
If you get a response with error-status of noError,
|
||
then the SET succeeded and the new key is active.
|
||
If you do not get a response, then you can issue a
|
||
GET(usmUserPublic) and check if the value is equal
|
||
to the randomValue you did send in the SET. If so, then
|
||
the key change succeeded and the new key is active
|
||
(probably the response got lost). If not, then the SET
|
||
request probably never reached the target and so you
|
||
can start over with the procedure above.
|
||
"
|
||
DEFVAL { ''H } -- the empty string
|
||
::= { usmUserEntry 6 }
|
||
|
||
usmUserOwnAuthKeyChange OBJECT-TYPE
|
||
SYNTAX KeyChange -- typically (SIZE (0 | 32)) for HMACMD5
|
||
-- typically (SIZE (0 | 40)) for HMACSHA
|
||
MAX-ACCESS read-create
|
||
STATUS current
|
||
DESCRIPTION "Behaves exactly as usmUserAuthKeyChange, with one
|
||
notable difference: in order for the set operation
|
||
to succeed, the usmUserName of the operation
|
||
requester must match the usmUserName that
|
||
indexes the row which is targeted by this
|
||
operation.
|
||
In addition, the USM security model must be
|
||
used for this operation.
|
||
The idea here is that access to this column can be
|
||
public, since it will only allow a user to change
|
||
his own secret authentication key (authKey).
|
||
Note that this can only be done once the row is active.
|
||
When a set is received and the usmUserName of the
|
||
requester is not the same as the umsUserName that
|
||
indexes the row which is targeted by this operation,
|
||
then a 'noAccess' error must be returned.
|
||
When a set is received and the security model in use
|
||
is not USM, then a 'noAccess' error must be returned.
|
||
"
|
||
DEFVAL { ''H } -- the empty string
|
||
::= { usmUserEntry 7 }
|
||
|
||
usmUserPrivProtocol OBJECT-TYPE
|
||
SYNTAX AutonomousType
|
||
MAX-ACCESS read-create
|
||
STATUS current
|
||
DESCRIPTION "An indication of whether messages sent on behalf of
|
||
this user to/from the SNMP engine identified by
|
||
usmUserEngineID, can be protected from disclosure,
|
||
and if so, the type of privacy protocol which is used.
|
||
An instance of this object is created concurrently
|
||
with the creation of any other object instance for
|
||
the same user (i.e., as part of the processing of
|
||
the set operation which creates the first object
|
||
instance in the same conceptual row).
|
||
If an initial set operation (i.e. at row creation time)
|
||
tries to set a value for an unknown or unsupported
|
||
protocol, then a 'wrongValue' error must be returned.
|
||
The value will be overwritten/set when a set operation
|
||
is performed on the corresponding instance of
|
||
usmUserCloneFrom.
|
||
Once instantiated, the value of such an instance of
|
||
this object can only be changed via a set operation to
|
||
the value of the usmNoPrivProtocol.
|
||
If a set operation tries to change the value of an
|
||
existing instance of this object to any value other
|
||
than usmNoPrivProtocol, then an 'inconsistentValue'
|
||
error must be returned.
|
||
Note that if any privacy protocol is used, then you
|
||
must also use an authentication protocol. In other
|
||
words, if usmUserPrivProtocol is set to anything else
|
||
than usmNoPrivProtocol, then the corresponding instance
|
||
of usmUserAuthProtocol cannot have a value of
|
||
usmNoAuthProtocol. If it does, then an
|
||
'inconsistentValue' error must be returned.
|
||
"
|
||
DEFVAL { usmNoPrivProtocol }
|
||
::= { usmUserEntry 8 }
|
||
|
||
usmUserPrivKeyChange OBJECT-TYPE
|
||
SYNTAX KeyChange -- typically (SIZE (0 | 32)) for DES
|
||
MAX-ACCESS read-create
|
||
STATUS current
|
||
DESCRIPTION "An object, which when modified, causes the secret
|
||
encryption key used for messages sent on behalf
|
||
of this user to/from the SNMP engine identified by
|
||
usmUserEngineID, to be modified via a one-way
|
||
function.
|
||
The associated protocol is the usmUserPrivProtocol.
|
||
The associated secret key is the user's secret
|
||
privacy key (privKey). The associated hash
|
||
algorithm is the algorithm used by the user's
|
||
usmUserAuthProtocol.
|
||
When creating a new user, it is an 'inconsistentName'
|
||
error for a set operation to refer to this object
|
||
unless it is previously or concurrently initialized
|
||
through a set operation on the corresponding instance
|
||
of usmUserCloneFrom.
|
||
When the value of the corresponding usmUserPrivProtocol
|
||
is usmNoPrivProtocol, then a set is successful, but
|
||
effectively is a no-op.
|
||
When this object is read, the zero-length (empty)
|
||
string is returned.
|
||
See the description clause of usmUserAuthKeyChange for
|
||
a recommended procedure to do a key change.
|
||
"
|
||
DEFVAL { ''H } -- the empty string
|
||
::= { usmUserEntry 9 }
|
||
|
||
usmUserOwnPrivKeyChange OBJECT-TYPE
|
||
SYNTAX KeyChange -- typically (SIZE (0 | 32)) for DES
|
||
MAX-ACCESS read-create
|
||
STATUS current
|
||
DESCRIPTION "Behaves exactly as usmUserPrivKeyChange, with one
|
||
notable difference: in order for the Set operation
|
||
to succeed, the usmUserName of the operation
|
||
requester must match the usmUserName that indexes
|
||
the row which is targeted by this operation.
|
||
In addition, the USM security model must be
|
||
used for this operation.
|
||
The idea here is that access to this column can be
|
||
public, since it will only allow a user to change
|
||
his own secret privacy key (privKey).
|
||
Note that this can only be done once the row is active.
|
||
When a set is received and the usmUserName of the
|
||
requester is not the same as the umsUserName that
|
||
indexes the row which is targeted by this operation,
|
||
then a 'noAccess' error must be returned.
|
||
When a set is received and the security model in use
|
||
is not USM, then a 'noAccess' error must be returned.
|
||
"
|
||
DEFVAL { ''H } -- the empty string
|
||
::= { usmUserEntry 10 }
|
||
|
||
usmUserPublic OBJECT-TYPE
|
||
SYNTAX OCTET STRING (SIZE(0..32))
|
||
MAX-ACCESS read-create
|
||
STATUS current
|
||
DESCRIPTION "A publicly-readable value which can be written as part
|
||
of the procedure for changing a user's secret
|
||
authentication and/or privacy key, and later read to
|
||
determine whether the change of the secret was
|
||
effected.
|
||
"
|
||
DEFVAL { ''H } -- the empty string
|
||
::= { usmUserEntry 11 }
|
||
|
||
usmUserStorageType OBJECT-TYPE
|
||
SYNTAX StorageType
|
||
MAX-ACCESS read-create
|
||
STATUS current
|
||
DESCRIPTION "The storage type for this conceptual row.
|
||
Conceptual rows having the value 'permanent' must
|
||
allow write-access at a minimum to:
|
||
- usmUserAuthKeyChange, usmUserOwnAuthKeyChange
|
||
and usmUserPublic for a user who employs
|
||
authentication, and
|
||
- usmUserPrivKeyChange, usmUserOwnPrivKeyChange
|
||
and usmUserPublic for a user who employs
|
||
privacy.
|
||
Note that any user who employs authentication or
|
||
privacy must allow its secret(s) to be updated and
|
||
thus cannot be 'readOnly'.
|
||
If an initial set operation tries to set the value to
|
||
'readOnly' for a user who employs authentication or
|
||
privacy, then an 'inconsistentValue' error must be
|
||
returned. Note that if the value has been previously
|
||
set (implicit or explicit) to any value, then the rules
|
||
as defined in the StorageType Textual Convention apply.
|
||
It is an implementation issue to decide if a SET for
|
||
a readOnly or permanent row is accepted at all. In some
|
||
contexts this may make sense, in others it may not. If
|
||
a SET for a readOnly or permanent row is not accepted
|
||
at all, then a 'wrongValue' error must be returned.
|
||
"
|
||
DEFVAL { nonVolatile }
|
||
::= { usmUserEntry 12 }
|
||
|
||
usmUserStatus OBJECT-TYPE
|
||
SYNTAX RowStatus
|
||
MAX-ACCESS read-create
|
||
STATUS current
|
||
DESCRIPTION "The status of this conceptual row.
|
||
Until instances of all corresponding columns are
|
||
appropriately configured, the value of the
|
||
corresponding instance of the usmUserStatus column
|
||
is 'notReady'.
|
||
In particular, a newly created row for a user who
|
||
employs authentication, cannot be made active until the
|
||
corresponding usmUserCloneFrom and usmUserAuthKeyChange
|
||
have been set.
|
||
Further, a newly created row for a user who also
|
||
employs privacy, cannot be made active until the
|
||
usmUserPrivKeyChange has been set.
|
||
The RowStatus TC [RFC2579] requires that this
|
||
DESCRIPTION clause states under which circumstances
|
||
other objects in this row can be modified:
|
||
The value of this object has no effect on whether
|
||
other objects in this conceptual row can be modified,
|
||
except for usmUserOwnAuthKeyChange and
|
||
usmUserOwnPrivKeyChange. For these 2 objects, the
|
||
value of usmUserStatus MUST be active.
|
||
"
|
||
::= { usmUserEntry 13 }
|
||
|
||
vacmContextName OBJECT-TYPE
|
||
SYNTAX SnmpAdminString (SIZE(0..32))
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "A human readable name identifying a particular
|
||
context at a particular SNMP entity.
|
||
The empty contextName (zero length) represents the
|
||
default context.
|
||
"
|
||
::= { vacmContextEntry 1 }
|
||
|
||
vacmGroupName OBJECT-TYPE
|
||
SYNTAX SnmpAdminString (SIZE(1..32))
|
||
MAX-ACCESS read-create
|
||
STATUS current
|
||
DESCRIPTION "The name of the group to which this entry (e.g., the
|
||
combination of securityModel and securityName)
|
||
belongs.
|
||
This groupName is used as index into the
|
||
vacmAccessTable to select an access control policy.
|
||
However, a value in this table does not imply that an
|
||
instance with the value exists in table vacmAccesTable.
|
||
"
|
||
::= { vacmSecurityToGroupEntry 3 }
|
||
|
||
vacmSecurityToGroupStorageType OBJECT-TYPE
|
||
SYNTAX StorageType
|
||
MAX-ACCESS read-create
|
||
STATUS current
|
||
DESCRIPTION "The storage type for this conceptual row.
|
||
Conceptual rows having the value 'permanent' need not
|
||
allow write-access to any columnar objects in the row.
|
||
"
|
||
DEFVAL { nonVolatile }
|
||
::= { vacmSecurityToGroupEntry 4 }
|
||
|
||
vacmSecurityToGroupStatus OBJECT-TYPE
|
||
SYNTAX RowStatus
|
||
MAX-ACCESS read-create
|
||
STATUS current
|
||
DESCRIPTION "The status of this conceptual row.
|
||
Until instances of all corresponding columns are
|
||
appropriately configured, the value of the
|
||
corresponding instance of the vacmSecurityToGroupStatus
|
||
column is 'notReady'.
|
||
In particular, a newly created row cannot be made
|
||
active until a value has been set for vacmGroupName.
|
||
The RowStatus TC [RFC2579] requires that this
|
||
DESCRIPTION clause states under which circumstances
|
||
other objects in this row can be modified:
|
||
The value of this object has no effect on whether
|
||
other objects in this conceptual row can be modified.
|
||
"
|
||
::= { vacmSecurityToGroupEntry 5 }
|
||
|
||
vacmAccessContextMatch OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{ exact (1), -- exact match of prefix and contextName
|
||
prefix (2) -- Only match to the prefix
|
||
}
|
||
MAX-ACCESS read-create
|
||
STATUS current
|
||
DESCRIPTION "If the value of this object is exact(1), then all
|
||
rows where the contextName exactly matches
|
||
vacmAccessContextPrefix are selected.
|
||
If the value of this object is prefix(2), then all
|
||
rows where the contextName whose starting octets
|
||
exactly match vacmAccessContextPrefix are selected.
|
||
This allows for a simple form of wildcarding.
|
||
"
|
||
DEFVAL { exact }
|
||
::= { vacmAccessEntry 4 }
|
||
|
||
vacmAccessReadViewName OBJECT-TYPE
|
||
SYNTAX SnmpAdminString (SIZE(0..32))
|
||
MAX-ACCESS read-create
|
||
STATUS current
|
||
DESCRIPTION "The value of an instance of this object identifies
|
||
the MIB view of the SNMP context to which this
|
||
conceptual row authorizes read access.
|
||
The identified MIB view is that one for which the
|
||
vacmViewTreeFamilyViewName has the same value as the
|
||
instance of this object; if the value is the empty
|
||
string or if there is no active MIB view having this
|
||
value of vacmViewTreeFamilyViewName, then no access
|
||
is granted.
|
||
"
|
||
DEFVAL { ''H } -- the empty string
|
||
::= { vacmAccessEntry 5 }
|
||
|
||
vacmAccessWriteViewName OBJECT-TYPE
|
||
SYNTAX SnmpAdminString (SIZE(0..32))
|
||
MAX-ACCESS read-create
|
||
STATUS current
|
||
DESCRIPTION "The value of an instance of this object identifies
|
||
the MIB view of the SNMP context to which this
|
||
conceptual row authorizes write access.
|
||
The identified MIB view is that one for which the
|
||
vacmViewTreeFamilyViewName has the same value as the
|
||
instance of this object; if the value is the empty
|
||
string or if there is no active MIB view having this
|
||
value of vacmViewTreeFamilyViewName, then no access
|
||
is granted.
|
||
"
|
||
DEFVAL { ''H } -- the empty string
|
||
::= { vacmAccessEntry 6 }
|
||
|
||
vacmAccessNotifyViewName OBJECT-TYPE
|
||
SYNTAX SnmpAdminString (SIZE(0..32))
|
||
MAX-ACCESS read-create
|
||
STATUS current
|
||
DESCRIPTION "The value of an instance of this object identifies
|
||
the MIB view of the SNMP context to which this
|
||
conceptual row authorizes access for notifications.
|
||
The identified MIB view is that one for which the
|
||
vacmViewTreeFamilyViewName has the same value as the
|
||
instance of this object; if the value is the empty
|
||
string or if there is no active MIB view having this
|
||
value of vacmViewTreeFamilyViewName, then no access
|
||
is granted.
|
||
"
|
||
DEFVAL { ''H } -- the empty string
|
||
::= { vacmAccessEntry 7 }
|
||
|
||
vacmAccessStorageType OBJECT-TYPE
|
||
SYNTAX StorageType
|
||
MAX-ACCESS read-create
|
||
STATUS current
|
||
DESCRIPTION "The storage type for this conceptual row.
|
||
Conceptual rows having the value 'permanent' need not
|
||
allow write-access to any columnar objects in the row.
|
||
"
|
||
DEFVAL { nonVolatile }
|
||
::= { vacmAccessEntry 8 }
|
||
|
||
vacmAccessStatus OBJECT-TYPE
|
||
SYNTAX RowStatus
|
||
MAX-ACCESS read-create
|
||
STATUS current
|
||
DESCRIPTION "The status of this conceptual row.
|
||
The RowStatus TC [RFC2579] requires that this
|
||
DESCRIPTION clause states under which circumstances
|
||
other objects in this row can be modified:
|
||
The value of this object has no effect on whether
|
||
other objects in this conceptual row can be modified.
|
||
"
|
||
::= { vacmAccessEntry 9 }
|
||
|
||
vacmViewSpinLock OBJECT-TYPE
|
||
SYNTAX TestAndIncr
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION "An advisory lock used to allow cooperating SNMP
|
||
Command Generator applications to coordinate their
|
||
use of the Set operation in creating or modifying
|
||
views.
|
||
When creating a new view or altering an existing
|
||
view, it is important to understand the potential
|
||
interactions with other uses of the view. The
|
||
vacmViewSpinLock should be retrieved. The name of
|
||
the view to be created should be determined to be
|
||
unique by the SNMP Command Generator application by
|
||
consulting the vacmViewTreeFamilyTable. Finally,
|
||
the named view may be created (Set), including the
|
||
advisory lock.
|
||
If another SNMP Command Generator application has
|
||
altered the views in the meantime, then the spin
|
||
lock's value will have changed, and so this creation
|
||
will fail because it will specify the wrong value for
|
||
the spin lock.
|
||
Since this is an advisory lock, the use of this lock
|
||
is not enforced.
|
||
"
|
||
::= { vacmMIBViews 1 }
|
||
|
||
vacmViewTreeFamilyMask OBJECT-TYPE
|
||
SYNTAX OCTET STRING (SIZE (0..16))
|
||
MAX-ACCESS read-create
|
||
STATUS current
|
||
DESCRIPTION "The bit mask which, in combination with the
|
||
corresponding instance of vacmViewTreeFamilySubtree,
|
||
defines a family of view subtrees.
|
||
Each bit of this bit mask corresponds to a
|
||
sub-identifier of vacmViewTreeFamilySubtree, with the
|
||
most significant bit of the i-th octet of this octet
|
||
string value (extended if necessary, see below)
|
||
corresponding to the (8*i - 7)-th sub-identifier, and
|
||
the least significant bit of the i-th octet of this
|
||
octet string corresponding to the (8*i)-th
|
||
sub-identifier, where i is in the range 1 through 16.
|
||
Each bit of this bit mask specifies whether or not
|
||
the corresponding sub-identifiers must match when
|
||
determining if an OBJECT IDENTIFIER is in this
|
||
family of view subtrees; a '1' indicates that an
|
||
exact match must occur; a '0' indicates 'wild card',
|
||
i.e., any sub-identifier value matches.
|
||
Thus, the OBJECT IDENTIFIER X of an object instance
|
||
is contained in a family of view subtrees if, for
|
||
each sub-identifier of the value of
|
||
vacmViewTreeFamilySubtree, either:
|
||
the i-th bit of vacmViewTreeFamilyMask is 0, or
|
||
the i-th sub-identifier of X is equal to the i-th
|
||
sub-identifier of the value of
|
||
vacmViewTreeFamilySubtree.
|
||
If the value of this bit mask is M bits long and
|
||
there are more than M sub-identifiers in the
|
||
corresponding instance of vacmViewTreeFamilySubtree,
|
||
then the bit mask is extended with 1's to be the
|
||
required length.
|
||
Note that when the value of this object is the
|
||
zero-length string, this extension rule results in
|
||
a mask of all-1's being used (i.e., no 'wild card'),
|
||
and the family of view subtrees is the one view
|
||
subtree uniquely identified by the corresponding
|
||
instance of vacmViewTreeFamilySubtree.
|
||
Note that masks of length greater than zero length
|
||
do not need to be supported. In this case this
|
||
object is made read-only.
|
||
"
|
||
DEFVAL { ''H }
|
||
::= { vacmViewTreeFamilyEntry 3 }
|
||
|
||
vacmViewTreeFamilyType OBJECT-TYPE
|
||
SYNTAX INTEGER { included(1), excluded(2) }
|
||
MAX-ACCESS read-create
|
||
STATUS current
|
||
DESCRIPTION "Indicates whether the corresponding instances of
|
||
vacmViewTreeFamilySubtree and vacmViewTreeFamilyMask
|
||
define a family of view subtrees which is included in
|
||
or excluded from the MIB view.
|
||
"
|
||
DEFVAL { included }
|
||
::= { vacmViewTreeFamilyEntry 4 }
|
||
|
||
vacmViewTreeFamilyStorageType OBJECT-TYPE
|
||
SYNTAX StorageType
|
||
MAX-ACCESS read-create
|
||
STATUS current
|
||
DESCRIPTION "The storage type for this conceptual row.
|
||
Conceptual rows having the value 'permanent' need not
|
||
allow write-access to any columnar objects in the row.
|
||
"
|
||
DEFVAL { nonVolatile }
|
||
::= { vacmViewTreeFamilyEntry 5 }
|
||
|
||
vacmViewTreeFamilyStatus OBJECT-TYPE
|
||
SYNTAX RowStatus
|
||
MAX-ACCESS read-create
|
||
STATUS current
|
||
DESCRIPTION "The status of this conceptual row.
|
||
The RowStatus TC [RFC2579] requires that this
|
||
DESCRIPTION clause states under which circumstances
|
||
other objects in this row can be modified:
|
||
The value of this object has no effect on whether
|
||
other objects in this conceptual row can be modified.
|
||
"
|
||
::= { vacmViewTreeFamilyEntry 6 }
|
||
|
||
END
|