smartLion DEFINITIONS ::= BEGIN
|
|
IMPORTS
|
|
internet
|
|
FROM RFC1155-SMI
|
|
MODULE-IDENTITY, NOTIFICATION-TYPE
|
|
FROM SNMPv2-SMI
|
|
hirschmann
|
|
FROM HMPRIV-MGMT-SNMP-MIB;
|
|
|
|
-- private OBJECT IDENTIFIER ::= { iso(1) org(3) dod(6) internet(1) 4 }
|
|
-- enterprises OBJECT IDENTIFIER ::= { private 1 }
|
|
-- hirschmann OBJECT IDENTIFIER ::= { enterprises 248 }
|
|
hiway OBJECT IDENTIFIER ::= { hirschmann 13 }
|
|
controlRoomSwitch OBJECT IDENTIFIER ::= { hiway 8 }
|
|
smartLion OBJECT IDENTIFIER ::= { controlRoomSwitch 1 }
|
|
|
|
-- 1.3.6.1.4.1.ENTERPRISE_ID.OEM_ID.0
|
|
contact MODULE-IDENTITY
|
|
LAST-UPDATED "0405060000Z"
|
|
ORGANIZATION "Hirschmann Automation and Control"
|
|
CONTACT-INFO
|
|
"Hirschmann Automation and Control GmbH
|
|
P.O. Box 1649
|
|
D-72602 Nuertingen
|
|
|
|
Germany"
|
|
DESCRIPTION
|
|
"The MIB module for Hirschmann Control Room Switch"
|
|
REVISION "0405060000Z"
|
|
DESCRIPTION
|
|
"Version 1.07"
|
|
::= { smartLion 0 }
|
|
|
|
switchInfo OBJECT IDENTIFIER ::= { smartLion 1 }
|
|
switchPortMgt OBJECT IDENTIFIER ::= { smartLion 2 }
|
|
systemSTAMgt OBJECT IDENTIFIER ::= { smartLion 3 }
|
|
tftpDownloadMgt OBJECT IDENTIFIER ::= { smartLion 4 }
|
|
restartMgt OBJECT IDENTIFIER ::= { smartLion 5 }
|
|
portMirrorMgt OBJECT IDENTIFIER ::= { smartLion 6 }
|
|
igmpMgt OBJECT IDENTIFIER ::= { smartLion 7 }
|
|
|
|
DisplayString ::= TEXTUAL-CONVENTION
|
|
DISPLAY-HINT "255a"
|
|
STATUS current
|
|
DESCRIPTION ""
|
|
SYNTAX OCTET STRING (SIZE (0..255))
|
|
|
|
PortList ::= OCTET STRING
|
|
|
|
--
|
|
-- switchInfo
|
|
--
|
|
|
|
-- 1.3.6.1.4.1.ENTERPRISE_ID.OEM_ID.TYPE.PRODUCT.1.1
|
|
switchNumber OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The total number of switches present on this system."
|
|
::= { switchInfo 1 }
|
|
|
|
-- 1.3.6.1.4.1.ENTERPRISE_ID.OEM_ID.TYPE.PRODUCT.1.2
|
|
switchInfoTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF SwitchInfoEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "Table of descriptive and status information about
|
|
switches in this system."
|
|
::= { switchInfo 2 }
|
|
|
|
-- 1.3.6.1.4.1.ENTERPRISE_ID.OEM_ID.TYPE.PRODUCT.1.2.1
|
|
switchInfoEntry OBJECT-TYPE
|
|
SYNTAX SwitchInfoEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "An entry in the table, containing information
|
|
about a single switch in this system. "
|
|
INDEX { swUnitIndex }
|
|
::= { switchInfoTable 1 }
|
|
|
|
SwitchInfoEntry ::= SEQUENCE
|
|
{
|
|
swUnitIndex Integer32,
|
|
swMainBoardHwVer DisplayString,
|
|
swMainBoardFwVer DisplayString,
|
|
swAgentBoardHwVer DisplayString,
|
|
swAgentBoardFwVer DisplayString,
|
|
swAgentBoardPOSTCodeVer DisplayString,
|
|
swPortNumber Integer32,
|
|
swPowerStatus INTEGER,
|
|
swExpansionSlot1 INTEGER,
|
|
swExpansionSlot2 INTEGER,
|
|
swRoleInSystem INTEGER,
|
|
swFan1Status INTEGER, -- added by roland
|
|
swFan2Status INTEGER -- added by roland
|
|
}
|
|
|
|
-- 1.3.6.1.4.1.ENTERPRISE_ID.OEM_ID.TYPE.PRODUCT.1.2.1.1
|
|
swUnitIndex OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "This object identifies the switch within the system
|
|
for which this entry contains information. This
|
|
value can never be greater than switchNumber."
|
|
::= { switchInfoEntry 1 }
|
|
|
|
-- 1.3.6.1.4.1.ENTERPRISE_ID.OEM_ID.TYPE.PRODUCT.1.2.1.2
|
|
swMainBoardHwVer OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..20))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Hardware(PCB) version of the main board."
|
|
::= { switchInfoEntry 2 }
|
|
|
|
-- 1.3.6.1.4.1.ENTERPRISE_ID.OEM_ID.TYPE.PRODUCT.1.2.1.3
|
|
swMainBoardFwVer OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..20))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Firmware version of the main board."
|
|
::= { switchInfoEntry 3 }
|
|
|
|
-- 1.3.6.1.4.1.ENTERPRISE_ID.OEM_ID.TYPE.PRODUCT.1.2.1.4
|
|
swAgentBoardHwVer OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..20))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Hardware version of the agent board."
|
|
::= { switchInfoEntry 4 }
|
|
|
|
-- 1.3.6.1.4.1.ENTERPRISE_ID.OEM_ID.TYPE.PRODUCT.1.2.1.5
|
|
swAgentBoardFwVer OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..20))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Firmware version of the agent board."
|
|
::= { switchInfoEntry 5 }
|
|
|
|
-- 1.3.6.1.4.1.ENTERPRISE_ID.OEM_ID.TYPE.PRODUCT.1.2.1.6
|
|
swAgentBoardPOSTCodeVer OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..20))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "POST code version of the agent board."
|
|
::= { switchInfoEntry 6 }
|
|
|
|
-- 1.3.6.1.4.1.ENTERPRISE_ID.OEM_ID.TYPE.PRODUCT.1.2.1.7
|
|
swPortNumber OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The total port number of this switch (
|
|
including expansion slot)."
|
|
::= { switchInfoEntry 7 }
|
|
|
|
-- 1.3.6.1.4.1.ENTERPRISE_ID.OEM_ID.TYPE.PRODUCT.1.2.1.8
|
|
swPowerStatus OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
internalPower(1),
|
|
redundantPower(2),
|
|
internalAndRedundantPower(3)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Indicates the switch using internalPower(1),
|
|
redundantPower(2) or both(3)"
|
|
::= { switchInfoEntry 8 }
|
|
|
|
-- 1.3.6.1.4.1.ENTERPRISE_ID.OEM_ID.TYPE.PRODUCT.1.2.1.9
|
|
swExpansionSlot1 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
hundredBaseFX2Port(1),
|
|
thousandBaseSX(2),
|
|
stackingModule4GB(3),
|
|
hundredBaseFX1Port(4),
|
|
thousandBaseLX(5),
|
|
thousandBaseT(6),
|
|
thousandBaseGBIC(7),
|
|
stackingModule2GB(8),
|
|
other(9),
|
|
notPresent(10),
|
|
tenHundredBaseT(11),
|
|
thousandBaseSXMtrj2Port(12),
|
|
thousandBaseSXSc2Port(13),
|
|
thousandBaseLXSc2Port(14),
|
|
hundredBaseFXMtrj2Port(15),
|
|
thousandBaseLXMtrj(16),
|
|
thousandBaseT2Port(17),
|
|
thousandBaseGBIC2Port(18)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Type of expansion module in this switch slot 1."
|
|
::= { switchInfoEntry 9 }
|
|
|
|
-- 1.3.6.1.4.1.ENTERPRISE_ID.OEM_ID.TYPE.PRODUCT.1.2.1.10
|
|
swExpansionSlot2 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
hundredBaseFX2Port(1),
|
|
thousandBaseSX(2),
|
|
stackingModule4GB(3),
|
|
hundredBaseFX1Port(4),
|
|
thousandBaseLX(5),
|
|
thousandBaseT(6),
|
|
thousandBaseGBIC(7),
|
|
stackingModule2GB(8),
|
|
other(9),
|
|
notPresent(10),
|
|
tenHundredBaseT(11),
|
|
thousandBaseSXMtrj2Port(12),
|
|
thousandBaseSXSc2Port(13),
|
|
thousandBaseLXSc2Port(14),
|
|
hundredBaseFXMtrj2Port(15),
|
|
thousandBaseLXMtrj(16),
|
|
thousandBaseT2Port(17),
|
|
thousandBaseGBIC2Port(18)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Type of expansion module in this switch slot 2."
|
|
::= { switchInfoEntry 10 }
|
|
|
|
-- 1.3.6.1.4.1.ENTERPRISE_ID.OEM_ID.TYPE.PRODUCT.1.2.1.11
|
|
swRoleInSystem OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
master(1),
|
|
backupMaster(2),
|
|
slave(3)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Indicates the switch is master(1), backupMaster(2)
|
|
or slave(3) in this system."
|
|
::= { switchInfoEntry 11 }
|
|
|
|
-- 1.3.6.1.4.1.ENTERPRISE_ID.OEM_ID.TYPE.PRODUCT.1.2.1.12
|
|
-- roland added. 2004.4.26.
|
|
swFan1Status OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
ok(1),
|
|
failed(2)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Indicates the switch fan 1 is working properly or not."
|
|
::= { switchInfoEntry 12 }
|
|
|
|
-- 1.3.6.1.4.1.ENTERPRISE_ID.OEM_ID.TYPE.PRODUCT.1.2.1.13
|
|
-- roland added. 2004.4.26.
|
|
swFan2Status OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
ok(1),
|
|
failed(2)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Indicates the switch fan 2 is working properly or not."
|
|
::= { switchInfoEntry 13 }
|
|
|
|
--
|
|
-- switchPortMgt
|
|
--
|
|
|
|
-- 1.3.6.1.4.1.ENTERPRISE_ID.OEM_ID.TYPE.PRODUCT.2.1
|
|
switchPortMgtTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF SwitchPortMgtEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "Table of descriptive and status information about
|
|
configuration of each switch ports(including expansion slot)
|
|
in this system."
|
|
::= { switchPortMgt 1 }
|
|
|
|
-- 1.3.6.1.4.1.ENTERPRISE_ID.OEM_ID.TYPE.PRODUCT.2.1.1
|
|
switchPortMgtEntry OBJECT-TYPE
|
|
SYNTAX SwitchPortMgtEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "An entry in the table, containing information
|
|
about configuration in one switch port of the switch."
|
|
INDEX { swUnitIndex, swPortMgtIndex }
|
|
::= { switchPortMgtTable 1 }
|
|
|
|
SwitchPortMgtEntry ::= SEQUENCE
|
|
{
|
|
swPortMgtIndex Integer32,
|
|
swPortMgtPortType INTEGER,
|
|
swPortMgtSpeedDpxAdmin INTEGER,
|
|
swPortMgtSpeedDpxInUse INTEGER,
|
|
swPortMgtFlowCtrlAdmin INTEGER,
|
|
swPortMgtFlowCtrlInUse INTEGER
|
|
}
|
|
|
|
-- 1.3.6.1.4.1.ENTERPRISE_ID.OEM_ID.TYPE.PRODUCT.2.1.1.1
|
|
swPortMgtIndex OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "This object identifies the port within the switch
|
|
for which this entry contains information."
|
|
::= { switchPortMgtEntry 1 }
|
|
|
|
-- 1.3.6.1.4.1.ENTERPRISE_ID.OEM_ID.TYPE.PRODUCT.2.1.1.2
|
|
swPortMgtPortType OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
hundredBaseTX(1),
|
|
hundredBaseFX(2),
|
|
thousandBaseSX(3),
|
|
thousandBaseLX(4),
|
|
thousandBaseT(5),
|
|
thousandBaseGBIC(6),
|
|
other(7),
|
|
notPresent(8)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Indicates the port type."
|
|
::= { switchPortMgtEntry 2 }
|
|
|
|
-- 1.3.6.1.4.1.ENTERPRISE_ID.OEM_ID.TYPE.PRODUCT.2.1.1.3
|
|
swPortMgtSpeedDpxAdmin OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
halfDuplex10(1),
|
|
fullDuplex10(2),
|
|
halfDuplex100(3),
|
|
fullDuplex100(4),
|
|
halfDuplex1000(5),
|
|
fullDuplex1000(6),
|
|
autoNegotiation(7)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Set the port speed and duplex mode as follows:
|
|
halfDuplex10(1) - 10Mbps and half duplex mode
|
|
fullDuplex10(2) - 10Mbps and full duplex mode
|
|
halfDuplex100(3) - 100Mbps and half duplex mode
|
|
fullDuplex100(4) - 100Mbps and full duplex mode
|
|
halfDuplex1000(5) - 1000Mbps and half duplex mode
|
|
fullDuplex1000(6) - 1000Mbps and full duplex mode
|
|
autoNegotiation(7) - let the switch to negotiate
|
|
with the other end of connection.
|
|
hundredBaseTX port can be set as
|
|
halfDuplex10(1)
|
|
fullDuplex10(2)
|
|
halfDuplex100(3)
|
|
fullDuplex100(4)
|
|
autoNegotiation(7)
|
|
hundredBaseFX port can be set as
|
|
halfDuplex100(3)
|
|
fullDuplex100(4)
|
|
thousandBaseSX port can be set as
|
|
halfDuplex1000(5)
|
|
fullDuplex1000(6)
|
|
autoNegotiation(7)
|
|
The actual operating speed and duplex of the port
|
|
is given by swPortMgtSpeedDpxInUse."
|
|
DEFVAL { autoNegotiation }
|
|
::= { switchPortMgtEntry 3 }
|
|
|
|
-- 1.3.6.1.4.1.ENTERPRISE_ID.OEM_ID.TYPE.PRODUCT.2.1.1.4
|
|
swPortMgtSpeedDpxInUse OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
halfDuplex10(1),
|
|
fullDuplex10(2),
|
|
halfDuplex100(3),
|
|
fullDuplex100(4),
|
|
halfDuplex1000(5),
|
|
fullDuplex1000(6)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The operating speed and duplex mode of the
|
|
switched port."
|
|
::= { switchPortMgtEntry 4 }
|
|
|
|
-- 1.3.6.1.4.1.ENTERPRISE_ID.OEM_ID.TYPE.PRODUCT.2.1.1.5
|
|
swPortMgtFlowCtrlAdmin OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
enabled(1),
|
|
disabled(2),
|
|
backPressure(3),
|
|
dot3xFlowControl(4)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "(1) Flow control mechanism is enabled.
|
|
If the port type is hundredBaseTX or thousandBaseSX:
|
|
When the port is operating in halfDuplex mode, the
|
|
port uses backPressure flow control mechanism. When
|
|
the port is operating in fullDuplex mode, the port
|
|
uses IEEE 802.3x flow control mechanism.
|
|
If the port type is hundredBaseFX:
|
|
When the port is operating in halfDuplex mode, the
|
|
port uses backPressure flow control mechanism. When
|
|
the port is operating in fullDuplex mode, Flow
|
|
control mechanism will not function.
|
|
(2) Flow control mechanism is disabled.
|
|
(3) Flow control mechanism is backPressure.
|
|
when the port is in fullDuplex mode.This flow control
|
|
mechanism will not function.
|
|
(4) Flow control mechanism is IEEE 802.3x flow control.
|
|
when the port is in halfDuplex mode.This flow control
|
|
mechanism will not function.
|
|
hundredBaseTX and thousandBaseSX port can be set as:
|
|
enabled(1),
|
|
disabled(2),
|
|
backPressure(3),
|
|
dot3xFlowControl(4).
|
|
hundredBaseFX port can be set as:
|
|
enabled(1),
|
|
disabled(2),
|
|
backPressure(3).
|
|
The actual flow control mechanism is used given by
|
|
swPortMgtFlowCtrlInUse."
|
|
DEFVAL { enabled }
|
|
::= { switchPortMgtEntry 5 }
|
|
|
|
-- 1.3.6.1.4.1.ENTERPRISE_ID.OEM_ID.TYPE.PRODUCT.2.1.1.6
|
|
swPortMgtFlowCtrlInUse OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
backPressure(1),
|
|
dot3xFlowControl(2),
|
|
none(3)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "(1) BackPressure flow control machanism is used.
|
|
(2) IEEE 802.3 flow control machanism is used.
|
|
(3) Flow control mechanism is disabled. "
|
|
::= { switchPortMgtEntry 6 }
|
|
|
|
--
|
|
-- systemSTAMgt
|
|
--
|
|
|
|
-- 1.3.6.1.4.1.ENTERPRISE_ID.OEM_ID.TYPE.PRODUCT.3.1
|
|
systemSTAStatus OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
enabled(1),
|
|
disabled(2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Global spanning tree status.
|
|
(1) Spanning tree protocol is enabled.
|
|
(2) Spanning tree protocol is disabled. "
|
|
--DEFVAL { disable }
|
|
::= { systemSTAMgt 1 }
|
|
|
|
--
|
|
-- tftpDownloadMgt
|
|
--
|
|
|
|
-- 1.3.6.1.4.1.ENTERPRISE_ID.OEM_ID.TYPE.PRODUCT.4.1
|
|
tftpDownloadServerIP OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "The IP address of a TFTP server from which a
|
|
firmware image can be downloaded."
|
|
DEFVAL { '00000000'H }
|
|
::= { tftpDownloadMgt 1 }
|
|
|
|
--tftpDownloadMainBoardFwFileName OBJECT-TYPE
|
|
-- SYNTAX DisplayString (SIZE(0..80))
|
|
-- MAX-ACCESS read-write
|
|
-- STATUS current
|
|
-- DESCRIPTION ""
|
|
-- DEFVAL { "" }
|
|
-- ::= { tftpDownloadMgt 2 }
|
|
|
|
--tftpDownloadMainBoardFwSelected OBJECT-TYPE
|
|
-- SYNTAX INTEGER
|
|
-- {
|
|
-- selected(1),
|
|
-- notSelected(2)
|
|
-- }
|
|
-- MAX-ACCESS read-write
|
|
-- STATUS current
|
|
-- DESCRIPTION "Setting this object as selected. The system will download
|
|
-- main board firmware when the download action be trigged."
|
|
-- DEFVAL { notSelected }
|
|
-- ::= { tftpDownloadMgt 3 }
|
|
|
|
-- 1.3.6.1.4.1.ENTERPRISE_ID.OEM_ID.TYPE.PRODUCT.4.2
|
|
tftpDownloadAgentBoardFwFileName OBJECT-TYPE
|
|
SYNTAX DisplayString(SIZE(0..80))
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION ""
|
|
DEFVAL { "HiSL107.bin" }
|
|
::= { tftpDownloadMgt 2 }
|
|
|
|
-- 1.3.6.1.4.1.ENTERPRISE_ID.OEM_ID.TYPE.PRODUCT.4.3
|
|
tftpDownloadAgentBoardFwDownloadFunction OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
backupConfiguration(1),
|
|
restoreConfiguration(2),
|
|
updateFirmware(3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "BackupConfiguration(1):Back up switch configuration to tftp server and
|
|
saving as a file.
|
|
RestoreConfiguration(2):Restore configuration file from tftp server
|
|
to switch.After restoring configuration, system will reboot automatically.
|
|
UpdateFirmware(3):Download new version firmware from tftp server and update
|
|
switch firmware.After update firmware, system will reboot automatically."
|
|
DEFVAL { updateFirmware }
|
|
::= { tftpDownloadMgt 3 }
|
|
|
|
--tftpDownloadAgentBoardFwSelected OBJECT-TYPE
|
|
-- SYNTAX INTEGER
|
|
-- {
|
|
-- selected(1),
|
|
-- notSelected(2)
|
|
-- }
|
|
-- MAX-ACCESS read-write
|
|
-- STATUS current
|
|
-- DESCRIPTION "Setting this object as selected. The system will download
|
|
-- agent board firmware when the download action be trigged."
|
|
-- DEFVAL { notSelected }
|
|
-- ::= { tftpDownloadMgt 4 }
|
|
|
|
-- 1.3.6.1.4.1.ENTERPRISE_ID.OEM_ID.TYPE.PRODUCT.4.4
|
|
tftpDownloadStatus OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
active(1),
|
|
notActive(2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Setting this object to active(1) triger the TFTP
|
|
download action.
|
|
Setting this object to notActive(2) has no effect.
|
|
The system always returns the value notActive(2)
|
|
when this object is read."
|
|
::= { tftpDownloadMgt 4 }
|
|
|
|
--
|
|
-- restartMgt
|
|
--
|
|
|
|
-- 1.3.6.1.4.1.ENTERPRISE_ID.OEM_ID.TYPE.PRODUCT.5.1
|
|
restartOptionPOST OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
enabled(1),
|
|
disabled(2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Setting this object as enabled. The system will do POST
|
|
when it restart"
|
|
DEFVAL { enabled }
|
|
::= { restartMgt 1 }
|
|
|
|
-- 1.3.6.1.4.1.ENTERPRISE_ID.OEM_ID.TYPE.PRODUCT.5.2
|
|
restartOptionReloadFactoryDefault OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
enabled(1),
|
|
disabled(2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Setting this object as enabled. The system will do factory
|
|
reset when it restart"
|
|
DEFVAL { disabled }
|
|
::= { restartMgt 2 }
|
|
|
|
-- 1.3.6.1.4.1.ENTERPRISE_ID.OEM_ID.TYPE.PRODUCT.5.3
|
|
restartOptionKeepIpSetting OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
enabled(1),
|
|
disabled(2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Setting this object as enabled. The system will keep IP
|
|
setting when it do factory reset."
|
|
DEFVAL { disabled }
|
|
::= { restartMgt 3 }
|
|
|
|
-- 1.3.6.1.4.1.ENTERPRISE_ID.OEM_ID.TYPE.PRODUCT.5.4
|
|
restartOptionKeepUserAuthentication OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
enabled(1),
|
|
disabled(2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Setting this object as enabled. The system will keep user
|
|
authentication setting when it do factory reset."
|
|
DEFVAL { disabled }
|
|
::= { restartMgt 4 }
|
|
|
|
-- 1.3.6.1.4.1.ENTERPRISE_ID.OEM_ID.TYPE.PRODUCT.5.5
|
|
restartAction OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
active(1),
|
|
notActive(2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Setting this object to active(1) triger the system
|
|
restart.
|
|
Setting this object to notActive(2) has no effect.
|
|
The system always returns the value notActive(2)
|
|
when this object is read."
|
|
::= { restartMgt 5 }
|
|
|
|
--
|
|
-- portMirrorMgt
|
|
--
|
|
|
|
-- 1.3.6.1.4.1.ENTERPRISE_ID.OEM_ID.TYPE.PRODUCT.6.1
|
|
portMirrorStatus OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
enabled(1),
|
|
disabled(2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Port mirroring function status.
|
|
(1) mirroring function is enabled.
|
|
(2) mirroring function is disabled."
|
|
::= { portMirrorMgt 1 }
|
|
|
|
-- 1.3.6.1.4.1.ENTERPRISE_ID.OEM_ID.TYPE.PRODUCT.6.2
|
|
portMirrorSnifferPort OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Port Id(1~26) of sniffer port to which all
|
|
frames to/from mirrored ports are sent. Frames
|
|
are only mirrored if the portMirrorStatus object
|
|
is set to enabled(1)."
|
|
::= { portMirrorMgt 2 }
|
|
|
|
-- 1.3.6.1.4.1.ENTERPRISE_ID.OEM_ID.TYPE.PRODUCT.6.3
|
|
portMirrorMirroredPort OBJECT-TYPE
|
|
SYNTAX PortList
|
|
--SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The set of ports which are mirrored. The traffic of
|
|
mirrored port will be 'copied' to sniffer port."
|
|
--DESCRIPTION "Linear port number of mirrored port. The traffic of
|
|
-- mirrored port will be 'copied' to sniffer port."
|
|
::= { portMirrorMgt 3 }
|
|
|
|
-- 1.3.6.1.4.1.ENTERPRISE_ID.OEM_ID.TYPE.PRODUCT.6.4
|
|
portMirrorMode OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
both(1),
|
|
rx(2),
|
|
tx(3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Port mirroring function mode.
|
|
(1) mirroring rx and tx frame.
|
|
(2) mirroring rx frame.
|
|
(3) mirroring tx frame."
|
|
::= { portMirrorMgt 4 }
|
|
--
|
|
-- igmpMgt
|
|
--
|
|
|
|
-- 1.3.6.1.4.1.ENTERPRISE_ID.OEM_ID.TYPE.PRODUCT.7.1
|
|
igmpStatus OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
enabled(1),
|
|
disabled(2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Parameter to enable or disable IGMP snooping on the device.
|
|
When enabled, the device will examine IGMP packets and set
|
|
up filters for IGMP ports. "
|
|
::= { igmpMgt 1 }
|
|
|
|
-- 1.3.6.1.4.1.ENTERPRISE_ID.OEM_ID.TYPE.PRODUCT.7.2
|
|
igmpQueryCount OBJECT-TYPE
|
|
SYNTAX INTEGER (2..10)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Maximum number of queries that have not been heard on the
|
|
system before the system starts taking action to solicit
|
|
reports."
|
|
DEFVAL { 2 }
|
|
::= { igmpMgt 2 }
|
|
|
|
|
|
-- 1.3.6.1.4.1.ENTERPRISE_ID.OEM_ID.TYPE.PRODUCT.7.3
|
|
igmpReportDelay OBJECT-TYPE
|
|
SYNTAX INTEGER (5..30)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Timeout value (seconds) between IGMP reports received on a port
|
|
for an IP Multicast Address that can pass before the system
|
|
sends an IGMP Query out the port and removes it from the
|
|
list."
|
|
DEFVAL { 10 }
|
|
::= { igmpMgt 3 }
|
|
|
|
--
|
|
-- Trap definitions
|
|
--
|
|
|
|
swFan1StatusChangeTrap TRAP-TYPE
|
|
ENTERPRISE smartLion
|
|
VARIABLES { swFan1Status }
|
|
DESCRIPTION "This trap is sent if the status of fan 1 has changed"
|
|
::= 1
|
|
|
|
swFan2StatusChangeTrap TRAP-TYPE
|
|
ENTERPRISE smartLion
|
|
VARIABLES { swFan2Status }
|
|
DESCRIPTION "This trap is sent if the status of fan 2 has changed"
|
|
::= 2
|
|
|
|
END
|
|
|