HM2-TSN-MIB DEFINITIONS ::= BEGIN
--
-- ***********************************************************
-- Hirschmann Time Sensitive Network MIB
-- ***********************************************************
--
IMPORTS
MODULE-IDENTITY, OBJECT-TYPE,
Integer32 FROM SNMPv2-SMI
hm2ConfigurationMibs,
HmEnabledStatus FROM HM2-TC-MIB
ieee8021STParametersEntry FROM IEEE8021-ST-MIB
TEXTUAL-CONVENTION FROM SNMPv2-TC;
hm2TsnMib MODULE-IDENTITY
LAST-UPDATED "201802060000Z" -- February 6, 2018
ORGANIZATION "Hirschmann Automation and Control GmbH"
CONTACT-INFO
"Postal: Stuttgarter Str. 45-51
72654 Neckartenzlingen
Germany
Phone: +49 7127 140
E-mail: hac.support@belden.com"
DESCRIPTION
"Hirschmann Time Sensitive Network MIB.
Copyright (C) 2018. All Rights Reserved."
REVISION "201802060000Z" -- February 6, 2018
DESCRIPTION
"Initial version."
REVISION "202102190000Z" -- February 19, 2021
DESCRIPTION
"Added hm2TsnTemplateBasedGroup."
REVISION "202103150000Z" -- March 15, 2021
DESCRIPTION
"Added hm2TsnConflictMibSESGroup for
SNMP extended error handling. ."
::= { hm2ConfigurationMibs 51 }
-- **************************************************************************************
Hm2TsnBaseTime ::= TEXTUAL-CONVENTION
DISPLAY-HINT
"2d-1d-1d,1d:1d:1d.4d"
STATUS current
DESCRIPTION
"A date-time specification for absolute time entry in a time range.
field octets contents range
----- ------ -------- -----
1 1-2 year 0..65536
2 3 month 1..12
3 4 day 1..31
4 5 hour 0..23
5 6 minutes 0..59
6 7 seconds 0..59
7 8-11 nanoseconds 0..4294967296
For example, Oct 9, 2009 at 1:30:45.4566 PM would be
displayed as:
2009-10-9,13:30:45.4566"
SYNTAX OCTET STRING (SIZE (11))
-- **************************************************************************************
--
-- ***********************************************************
-- hm2TsnbMib
-- ***********************************************************
--
hm2TsnNotifications OBJECT IDENTIFIER ::= { hm2TsnMib 0 }
hm2TsnMibObjects OBJECT IDENTIFIER ::= { hm2TsnMib 1 }
-- hm2TsnMibConformance OBJECT IDENTIFIER ::= { hm2TsnMib 2 }
hm2TsnMibSNMPExtensionGroup OBJECT IDENTIFIER ::= { hm2TsnMib 3 }
--
-- ***********************************************************
-- hm2Tsn Groups
-- ***********************************************************
--
hm2TsnGroup OBJECT IDENTIFIER ::= { hm2TsnMibObjects 1 }
-- ****************************************************************************
-- TSN Group
-- ****************************************************************************
hm2TsnAdminState OBJECT-TYPE
SYNTAX HmEnabledStatus
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The TSN protocol group administrative status."
DEFVAL { disable }
::= { hm2TsnGroup 1 }
-- ****************************************************************************
-- Parameters Entry
-- ****************************************************************************
hm2STParametersTable OBJECT-TYPE
SYNTAX SEQUENCE OF Hm2STParametersEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
""
::= { hm2TsnMibObjects 2 }
hm2STParametersEntry OBJECT-TYPE
SYNTAX Hm2STParametersEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
""
AUGMENTS { ieee8021STParametersEntry }
::= { hm2STParametersTable 1 }
Hm2STParametersEntry ::=
SEQUENCE {
hm2STAdminBaseTime Hm2TsnBaseTime,
hm2STOperBaseTime Hm2TsnBaseTime,
hm2STConfigChangeTime Hm2TsnBaseTime,
hm2STPortStatus INTEGER
}
hm2STAdminBaseTime OBJECT-TYPE
SYNTAX Hm2TsnBaseTime
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The administrative value of the BaseTime parameter for the port."
::= { hm2STParametersEntry 1 }
hm2STOperBaseTime OBJECT-TYPE
SYNTAX Hm2TsnBaseTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The operational value of the BaseTime parameter for the port."
::= { hm2STParametersEntry 2 }
hm2STConfigChangeTime OBJECT-TYPE
SYNTAX Hm2TsnBaseTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of the ConfigChangeTime parameter for the port."
::= { hm2STParametersEntry 3 }
hm2STPortStatus OBJECT-TYPE
SYNTAX INTEGER { running(1),
waitForTimeSync(2),
pending(3),
disabled(4),
error(5)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The operational value of cycle status on the port"
::= { hm2STParametersEntry 4 }
-- ***********************************************************
-- TSN Template Based Group
-- ***********************************************************
hm2TsnTemplateBasedGroup OBJECT IDENTIFIER ::= { hm2TsnMibObjects 3 }
hm2TsnTemplateBasedParametersTable OBJECT-TYPE
SYNTAX SEQUENCE OF Hm2TsnTemplateBasedParametersEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
""
::= { hm2TsnTemplateBasedGroup 1 }
hm2TsnTemplateBasedParametersEntry OBJECT-TYPE
SYNTAX Hm2TsnTemplateBasedParametersEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
""
AUGMENTS { ieee8021STParametersEntry }
::= { hm2TsnTemplateBasedParametersTable 1 }
Hm2TsnTemplateBasedParametersEntry ::=
SEQUENCE {
hm2TsnAdminTemplateGcl INTEGER,
hm2TsnOperTemplateGcl INTEGER
}
hm2TsnAdminTemplateGcl OBJECT-TYPE
SYNTAX INTEGER {
noop(1),
tc7Tc6to0Gb(2),
gbTc7Tc6to0(3),
tc6to0GbTc7(4),
gbTc7GbTc6Tc5to0(5),
tc5to0GbTc7GbTc6(6),
gbTc6GbTc7Tc5to0(7),
gbTc7Tc5to0GbTc6(8),
tc7GbTc6Tc5to0Gb(9)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Administrative value of presetting the TSN gate control list
with a template.
Writing noop(1) has no effect. When reading this object,
it returns noop(1).
When writing tc7Tc6to0Gb(2) the number of entries (TLVs) in the
ieee8021STAdminControlList will be preassigned to 3,
in the ieee8021STAdminControlList the first entry represents
traffic class 7,
the second entry represents the traffic classes 6 to 0,
and the third entry represents a guard band.
When writing gbTc7Tc6to0(3) the number of entries (TLVs) in the
ieee8021STAdminControlList will be preassigned to 3,
in the ieee8021STAdminControlList the first entry represents
a guard band,
the second entry represents the traffic class 7,
and the third entry represents the traffic classes 6 to 0.
When writing tc6to0GbTc7(4) the number of entries (TLVs) in the
ieee8021STAdminControlList will be preassigned to 3,
in the ieee8021STAdminControlList the first entry represents
the traffic classes 6 to 0,
the second entry represents a guard band,
and the third entry represents the traffic class 7.
When writing gbTc7GbTc6Tc5to0(5) the number of entries (TLVs) in the
ieee8021STAdminControlList will be preassigned to 5,
in the ieee8021STAdminControlList the first entry represents
a guard band,
the second entry represents the traffic class 7,
the third entry represents a guard band,
the fourth entry represents the traffic class 6,
and the fifth entry represents the traffic classes 5 to 0.
When writing tc5to0GbTc7GbTc6(6) the number of entries (TLVs) in the
ieee8021STAdminControlList will be preassigned to 5,
in the ieee8021STAdminControlList the first entry represents
the traffic classes 5 to 0,
the second entry represents a guard band,
the third entry represents the traffic class 7,
the fourth entry represents a guard band,
and the fifth entry represents the traffic class 6.
When writing gbTc6GbTc7Tc5to0(7) the number of entries (TLVs) in the
ieee8021STAdminControlList will be preassigned to 5,
in the ieee8021STAdminControlList the first entry represents
a guard band,
the second entry represents the traffic class 6,
the third entry represents a guard band,
the fourth entry represents the traffic class 7,
and the fifth entry represents the traffic classes 5 to 0.
When writing gbTc7Tc5to0GbTc6(8) the number of entries (TLVs) in the
ieee8021STAdminControlList will be preassigned to 5,
in the ieee8021STAdminControlList the first entry represents
a guard band,
the second entry represents the traffic class 7,
the third entry represents the traffic classes 5 to 0,
the fourth entry represents a guard band,
and the fifth entry represents the traffic class 6.
When writing tc7GbTc6Tc5to0Gb(9) the number of entries (TLVs) in the
ieee8021STAdminControlList will be preassigned to 5,
in the ieee8021STAdminControlList the first entry represents
traffic class 7,
the second entry represents a guard band,
the third entry represents the traffic class 6,
the fourth entry represents the traffic classes 5 to 0,
and the fifth entry represents a guard band.
"
DEFVAL { noop }
::= { hm2TsnTemplateBasedParametersEntry 1 }
hm2TsnOperTemplateGcl OBJECT-TYPE
SYNTAX INTEGER {
noTemplate(1),
tc7Tc6to0Gb(2),
gbTc7Tc6to0(3),
tc6to0GbTc7(4),
gbTc7GbTc6Tc5to0(5),
tc5to0GbTc7GbTc6(6),
gbTc6GbTc7Tc5to0(7),
gbTc7Tc5to0GbTc6(8),
tc7GbTc6Tc5to0Gb(9)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Operational value of presetting the TSN gate control list with a template.
noTemplate(1) indicates that the TSN gate control list was not presetted
with a template.
tc7Tc6to0Gb(2) indicates that the number of entries (TLVs) in the
ieee8021STAdminControlList was preassigned to 3,
in the ieee8021STAdminControlList the first entry represents
traffic class 7,
the second entry represents the traffic classes 6 to 0,
and the third entry represents a guard band.
gbTc7Tc6to0(3) indicates that the number of entries (TLVs) in the
ieee8021STAdminControlList was preassigned to 3,
in the ieee8021STAdminControlList the first entry represents
a guard band,
the second entry represents the traffic class 7,
and the third entry represents the traffic classes 6 to 0.
tc6to0GbTc7(4) indicates that the number of entries (TLVs) in the
ieee8021STAdminControlList was preassigned to 3,
in the ieee8021STAdminControlList the first entry represents
the traffic classes 6 to 0,
the second entry represents a guard band,
and the third entry represents the traffic class 7.
gbTc7GbTc6Tc5to0(5) indicates that the number of entries (TLVs) in the
ieee8021STAdminControlList was preassigned to 5,
in the ieee8021STAdminControlList the first entry represents
a guard band,
the second entry represents the traffic class 7,
the third entry represents a guard band,
the fourth entry represents the traffic class 6,
and the fifth entry represents the traffic classes 5 to 0.
tc5to0GbTc7GbTc6(6) indicates that the number of entries (TLVs) in the
ieee8021STAdminControlList was preassigned to 5,
in the ieee8021STAdminControlList the first entry represents
the traffic classes 5 to 0,
the second entry represents a guard band,
the third entry represents the traffic class 7,
the fourth entry represents a guard band,
and the fifth entry represents the traffic class 6.
gbTc6GbTc7Tc5to0(7) indicates that the number of entries (TLVs) in the
ieee8021STAdminControlList was preassigned to 5,
in the ieee8021STAdminControlList the first entry represents
a guard band,
the second entry represents the traffic class 6,
the third entry represents a guard band,
the fourth entry represents the traffic class 7,
and the fifth entry represents the traffic classes 5 to 0.
gbTc7Tc5to0GbTc6(8) indicates that the number of entries (TLVs) in the
ieee8021STAdminControlList was preassigned to 5,
in the ieee8021STAdminControlList the first entry represents
a guard band,
the second entry represents the traffic class 7,
the third entry represents the traffic classes 5 to 0,
the fourth entry represents a guard band,
and the fifth entry represents the traffic class 6.
tc7GbTc6Tc5to0Gb(9) indicates that the number of entries (TLVs) in the
ieee8021STAdminControlList was preassigned to 5,
in the ieee8021STAdminControlList the first entry represents
traffic class 7,
the second entry represents a guard band,
the third entry represents the traffic class 6,
the fourth entry represents the traffic classes 5 to 0,
and the fifth entry represents a guard band.
"
::= { hm2TsnTemplateBasedParametersEntry 2 }
--*****************************************************************************
-- hm2TsnMibSNMPExtensionGroup
--*****************************************************************************
hm2TsnConflictMibSESGroup OBJECT IDENTIFIER ::= { hm2TsnMibSNMPExtensionGroup 1 }
-- *************************************************************
-- hm2TsnConflictMibSESGroup notifications
-- *************************************************************
hm2TsnGranulaityConflict OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Indicates that either the configured cycle time or GCL interval
does not conform to the granularity of cycle time range.
For cycle time till 4ms, granularity is 1000ns.
For cycle time between 4ms and 8ms, granularity is 2000ns.
For cycle time greater than 8ms, granularity is 4000ns.
"
::= { hm2TsnConflictMibSESGroup 1 }
hm2TsnGCLTimeIntervalConflit OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Indicates that sum of the time interval of all GCL entries exceeds
the configured cycle time."
::= { hm2TsnConflictMibSESGroup 2 }
hm2TsnGCLTemplateConflict OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Indicates that configured GCL entry does not match to any of the
available GCL templates."
::= { hm2TsnConflictMibSESGroup 3 }
END